SECTION. Occupancy Sensors & Lighting Control Products
|
|
- Gabriel Lynch
- 6 years ago
- Views:
Transcription
1 SECTIO s & Lighting Control Products
2 Infrared s Features and Types Leviton provides a variety of spacemonitoring Lighting Controls for virtually any room, space, facility, home or office. Wall or ceiling, passive infrared or ultrasonic, end users will benefit from Leviton's s as a direct result of their energy efficiency and obvious cost-effectiveness. Features and Benefits - ODS15-ID 180 field of view, covers approximately 2100 square feet Selectable base time-delay interval from 30 seconds to 20 minutes Self-adjusting delayed off time interval compensates for real time occupancy patterns, preventing unnecessary on/off switching Can be used with incandescent or fluorescent lighting Motion-activated; infrared sensing technology turns lights O when room is occupied and OFF when unoccupied Replaces standard switches in existing wallboxes Ambient light override keeps lights off when there s plenty of sunlight Push-button manual override allows controls to be used like standard O/OFF switches; manual-o/auto-off mode Walk-Through feature shuts off lights after 2 1 /2 minutes rather than an extended period Compatible with Decora designer-styled devices Backed by a Limited Five-Year Warranty Passive Infrared (PIR) detection technology to monitor room for occupancy Sensor automatically sends signal to switch lights on and keep them on when room is occupied and activity detected Adjustable delayed off-time (30 seconds 20 minutes) LED indicator light flashes when sensor detects motion Versatile Lighting Controls for Cost-Effective Energy Savings PAGE 3 Dual-Relay Decora Wall Switch Infrared Occupancy Sensor Controls two separate lighting loads from a single unit. Features self-adjusting technology for maximum performance. Self-Contained Ceiling Mount PIR Contains sensor and switching relay; 360 field of view; adjustable delayed off time of 20 seconds to 15 minutes. PAGE 4 Fresnel lenses for small motion detection to monitor movement in room ODS15 SERIES To learn more about Leviton's Architectural Lighting Control Systems, Box-Mounted Dimmers, Fan Speed Controls, Timers, and Home Automation Products request a Lighting Controls Product Catalog. 180 field of view, 2,100 square feet of coverage Ambient light override prevents the sensor from switching lights on when there is ample natural sunlight Multi-Technology Ceiling- Mount Combines infrared and ultrasonic technology for highly accurate monitoring. 360, 2000 sq. ft coverage. PAGES PAGE 8 Multi- Technology Wall-Mount Occupancy Sensor Combines infrared and ultrasonic technology for highly accurate monitoring. 110, 1200 sq. ft coverage. PAGE 9 Infrared High- Bay Wall-Mount Occupancy Sensor Ideal for ware house aisles, hallways, stairways and other long, narrow spaces. Outdoor Motion Sensor Ideal for commercial/industrial settings, with temperature compensation to ensure performance in all weather conditions. PAGE or visit us at:
3 The Centura System Centura Fluorescent Management System SPECIFICATIOS & FEATURES STADARDS & CERTIFICATIOS COMMERCIAL GRADE CETURA FLUORESCET MAAGEMET SYSTEM UL Listed CSA Ideal for commercial spaces and individual offices. Reduces eyestrain and fatigue from glare, increasing comfort and productivity. All functions conveniently accessed through Entry Station Wall Switch Users do not have to make adjustments at ceiling unit. Dimming Power Pack provides low-voltage power supply for Entry Stations, Photocell and s. Photocell provides energy savings through Daylight Harvesting technology. Use with Leviton s for increased energy savings: Lights turn O automatically to programmed levels when personnel enter area; OFF automatically when area becomes vacant. Modular system design expands energy saving options with an interface for building emergency systems, load shedding programs and time clock systems. Dimming Power Pack mounts in standard box. Wall Switch Entry Stations mount in standard single-gang switch box 4"x4" square. Centura Fluorescent Energy Management System C100-0D0 C221-00C Leviton's new Centura, a modular lighting control system for dimming fluorescent ballasts (Advance Mark VII, 0-10V and Osram Sylvania Quicktronic Helios, brings increased energy savings to commercial spaces. Using a technique known as daylight harvesting, Centura factors in the available daylight for the precise control of fluorescent light levels to achieve optimum comfort and energy efficiency. White COLOR CATALOG DESCRIPTIO RATIG UMBER Centura Fluorescent Energy Management System Gray Metallic C100 Centura Dimming Power Pack O/OFF and DIM/BRIGHT control of dimming fluorescent ballasts. Responds to Entry Station, and Photocell input and provides +24 VDC power supply for these devices. Programmed via Entry Station. Secondary relay sends control signals to HVAC system. LED's indicate operation mode. Clear C200-00C 5 Button Dimming Entry Station This entry station allows manual control of the dimming power pack. Its buttons are On, (Ivory color change Max, Bright, Dim, and Off.The buttons are illuminated when kit included) selected. Also, it has an infrared port to be controlled by a matching remote control and has the ability to program the Max, Min., and Daylight Maintain levels. (Ivory color change kit included) White (Ivory color change kit included) White White (Ivory color change kit included) Black C220-00C C221-00C ODC0P E100-00C E200-E CETURA EERGY MAAGEMET SYSTEM ESSETIAL COMPOETS 2 Button Entry Station This entry station allows manual control of the dimming power pack for applications for non-dim loads. It is the Mural (MS) style. Its buttons are On and Off. Centura Entry Station Wall Switch Decora-style rocker for O/OFF switching with built-in arrow-shaped rocker for DIM/BRIGHT control. LED display indicates selected brightness level. Programs all energy management functions back of wallplate provides instruction label that lines up with LED s to facilitate programming. Centura Photocell Detects available light levels for Daylight Harvesting. Allows Centura system to maintain a programmed light level by constantly adjusting fluorescent light output to compensate for available daylight. OCCUPACY SESOR PHOTOCELL Cat. o. ODC0P 120V AC 60Hz, 277V AC 60Hz For use with Advance Mark VII, 0-10V and Osram Sylvania Quicktronic Helios and comparable ballasts only o load rating, for use with Centura Dimming Power Pack only o load rating, for use with Centura Dimming Power Pack only o load rating, for use with Centura Dimming Power Pack only o load rating, for use with Centura Dimming Power Pack only Smart Jack The Smart Jack makes all the above mentioned items networkable through a PC or a remote PC via an ethernet link.the Smart Jack will also come with the computer soft- Dimming Power Pack only o load rating, for use with Centura ware for the server and client applications. Hand-Held Remote Control The remote control will match the functionality of the 5 Button Entry Station ETRY STATIO Cat. o. C221 s - The Centura System Phase eutral Dimming Power Pack Cat. o. C V DC Ballast POWER (+24V) GROUD OCCUPAY CA_H CA_L PHOTCELL DIM RETUR HVAC O HVAC C HVAC COMM. HVAC Interface or visit us at: 2
4 Infrared s Wall Switches SPECIFICATIOS & FEATURES DECORA WALL SWITCH DUAL-RELAY DECORA WALL SWITCH IFRARED IFRARED OCCUPACY WALL SWITCH IFRARED OCCUPACY SESOR SESOR (ODS15-ID) OCCUPACY SESOR (ODS0D-ID) (ODS10-ID) For use in small offices, conference rooms, class rooms, stock rooms, lounges, restrooms, warehouses & commercial areas. Automatic Walk-Through sensing increases energy savings by shutting lights within minutes after momentary occupancy. Self-adjusting delayed OFF-time interval compensates for real-time occupancy patterns, preventing unnecessary O/OFF switching. 180 field of view, 2100 sq. ft. of coverage. Ideal for class & conference rooms. Automatic Walk Through sensing. Automatic switching for 2 separate banks of fluorescent, incandescent, or low-voltage lighting from a single unit. Self-adjusting delayed OFF-time interval compensates for real-time occupancy patterns, preventing unnecessary O/OFF switching. 180 field of view, 2100 sq. ft. of coverage. Ambient light override prevents these devices from switching lights O when there is ample natural sunlight. Push-button manual override is used to turn lights O at any time, regardless of the override setting. For use in enclosed offices, storage rooms, copier rooms & closets. One unit can be used for 120V or 277VAC 60Hz incandescent, low-voltage and fluorescent lighting with either magnetic or electronic ballasts, and motor loads. 180 field of view, 2,100 sq. ft. of coverage. Fits in standard wallbox; gangable. Delayed-off time setting (30 seconds 30 minutes). Elegant Decora styling; uses Decora wallplate. Dual-Relay Decora Wall Switch Infrared s Adaptive Dual Relay s: Ivory ODS0D-IDI Conference Room Mode Both Primary and Secondary Relays respond to Ambient White ODS0D-IDW Light Override. Gray ODS0D-IDG Alternate Setting: Classroom Mode Primary Relay only responds to Ambient Light Almond ODS0D-IDA Override. Decora Wall Switch Infrared (Incandescent and Fluorescent) STADARDS & CERTIFICATIOS CUL/US UL CSA OM Listed C22.2 o. 205 ODSOD Only ODS0D-IDW with W plate #E #LR-91148M #057 EVIROMETAL STORAGE TEMP. OPERATIG TEMP. -10C to 85C COLOR CATALOG UMBER DESCRIPTIO RATIG 0C to 50C ODS15-IDW with W plate Primary Relay: Fluorescent: 277V Incandescent: Secondary Relay: Fluorescent: 1200VA 277V Incandescent: COLOR CATALOG UMBER DESCRIPTIO RATIG Decora Wall Switch Infrared (Incandescent and Fluorescent) Ivory ODS10-IDI Fluorescent: 120V, White ODS10-IDW Infrared 277V Gray ODS10-IDG s Incandescent: 120V Almond ODS10-IDA Motor: 1 /4 120V COLOR CATALOG UMBER DESCRIPTIO RATIG Ivory ODS15-IDI Fluorescent: 120V, White ODS15-IDW Adaptive Infrared 277V Gray ODS15-IDG s Incandescent: 120V Almond ODS15-IDA Motor: 1 /4 120V 1.75 (44.4 mm) 1.30 (33.0 mm) 0.49 (12.6 mm) 1.35 (34.3 mm) 3 OFF O AUTO BOTTOM 2.61 (66.3 mm) 4.06 (103.2 mm) ODS15-ID 2.60 (66.1 mm) or visit us at:
5 Infrared s SPECIFICATIOS & FEATURES COMMERCIAL GRADE SELF-COTAIED CEILIG-MOUT OCCUPACY SESORS PIR with built-in relay Separate Power Pack not required. Ideal for use in storage areas, small bathrooms, copy rooms and a variety of small spaces without wall switches. Full 360 view of a 530 sq. ft. area when surface mounted on standard, 8-foot ceiling. Sensor and switching relay combined in a single self-contained unit o control unit required. Ambient light override option prevents lights from turning O when there is ample natural light. Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes. Small, unobtrusive self-contained unit: 4.3" (109.2 mm) diameter (54.6 mm) STADARDS & CERTIFICATIOS UL CSA Listed ODC0S-I1W COLOR CATALOG UMBER DESCRIPTIO COVERAGE RATIG Self-Contained Ceiling-Mount s White ODC0S-I1W Self-Contained Ceiling-Mount 360, 530 sq. ft. Incandescent: 120V (formerly ) Infrared and Switching Relay 120V For 60Hz AC only. 1HP@120V AC White ODC0S-I2W Self-Contained Ceiling-Mount 360, 530 sq. ft. Incandescent: 220V Infrared and Switching Relay 220V For 50Hz AC only. White ODC0S-I7W Self-Contained Ceiling-Mount 360, 530 sq. ft. (formerly ) Infrared 277V For 60Hz AC only. and Switching Relay White ODCCG-000 Protective Cage Self-Contained Ceiling-Mount s ODC0S-I1W 4.3 (109.2 mm) or visit us at: 4
6 Multi-Tech. s Ceiling Mount s SPECIFICATIOS & FEATURES MULTI-TECH CEILIG MOUT OCCUPACY SESORS For office areas, warehouse and storage facilities, and public areas in commercial facilities. Ultrasonic sensing with Passive Infrared (PIR) sensing. Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, longterm performance. Built-in Circadian Calendar Provides 4-week learning period to establish trends that serve as the basis for automatic operation. In peak occupancy periods the sensor remains in high-sensitivity mode and in low occupancy periods it switches to economy mode. Manual Delayed-OFF time settings of 8, 16, & 32 minutes. Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes. Preserves all automatic and manual settings during power outages. Choice of coverage patterns to suits a variety of applications. Small, unobtrusive size (4.5" diameter) blends in with any décor. Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit contains Adapter Base and rotate and lock Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box. OPTIOAL PERFORMACE FEATURES For Models with -MRW Suffix Ambient light override option prevents lights from turning O when there is ample natural light. Secondary Relay Single- Pole Double-Throw (SPDT), rated V AC/DC, three-wire isolated relay. Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection. STADARDS & CERTIFICATIOS CUL/US ODC20-M0W Multi-Technology Ceiling-Mount (For use with Leviton Power Pack) Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital self-adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton s to Cat. o. ODP20 Power Pack (purchased separately). See page 10 for Power Pack information. COLOR CATALOG UMBER DESCRIPTIO COVERAGE OPERATIG FREQUECY Ceiling-Mount s White ODC05-M0W Multi-Tech Ceiling-Mount 180, 500 sq. ft. 40kHz Multi-Tech Ceiling-Mount White ODC05-MRW with Ambient 180, 500 sq. ft. 40kHz White ODC10-M0W Multi-Tech Ceiling-Mount 180, 1000 sq. ft. 32kHz Multi-Tech Ceiling-Mount White ODC10-MRW with Ambient 180, 1000 sq. ft. 32kHz White ODC20-M0W Multi-Tech Ceiling-Mount 360, 2000 sq. ft. 32kHz Multi-Tech Ceiling-Mount White ODC20-MRW with Ambient 360, 2000 sq. ft. 32kHz White ODCRA-000 Hard-Ceiling Raceway Adapter Kit White ODCCG-000 Protective Cage for Ceiling-Mount s 1.40 (35.6 mm) ø 4.53 (115.1 mm) 1.40 (35.6 mm) ø 4.53 (115.1 mm) 5 ODC05-M, ODC10-M ODC20-M or visit us at:
7 Ultrasonic s SPECIFICATIOS & FEATURES ULTRASOIC CEILIG MOUT OCCUPACY SESORS Ideal for restrooms, office areas with cubicles, general work space, warehouse and storage facilities, cafeterias and public areas in commercial facilities. Ultrasonic sensing for maximum range and sensitivity. Self-adjusting settings continuously analyze and adjust sensitivity, timer operation, and air current compensation. Automatic dual-mode operation adjusts to either economy or high-sensitivity mode based on actual occupancy patterns. Built-in Circadian Calendar Provides 4-week learning period to establish trends that serve as the basis for automatic operation. In peak occupancy periods the sensor remains in high-sensitivity mode and in low occupancy periods it switches to economy mode. Manual Delayed-OFF time settings of 8, 16, & 32 minutes. Choice of coverage patterns to suits a variety of applications. Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post. Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceil rotate and lock Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box. OPTIOAL PERFORMACE FEATURES For Models with -URW Suffix Ambient light override option prevents lights from turning O when there is ample natural light. Secondary Relay Single- Pole Double-Throw (SPDT), rated V AC/DC, three-wire isolated relay. Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection. STADARDS & CERTIFICATIOS CUL/US ODC10-U0W Ultrasonic Ceiling-Mount (For use with Leviton Power Pack) Advanced Ultrasonic sensing technology for highly accurate monitoring with excellent immunity to air currents and other interference. All-digital self-adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton s to Cat. o. ODP20 Power Pack (purchased separately). See page 10 for Power Pack information. COLOR CATALOG UMBER DESCRIPTIO COVERAGE OPERATIG FREQUECY Ultrasonic Ceiling-Mount s White ODC05-U0W Ultrasonic Ceiling-Mount 180, 500 sq. ft. 40kHz White ODC05-URW Ultrasonic Ceiling-Mount 180, 500 sq. ft. 40kHz with Ambient White ODC10-U0W Ultrasonic Ceiling-Mount 180, 1000 sq. ft. 32kHz White ODC10-URW Ultrasonic Ceiling-Mount 180, 1000 sq. ft. 32kHz with Ambient White ODC20-U0W Ultrasonic Ceiling-Mount 360, 2000 sq. ft. 32kHz White ODC20-URW Ultrasonic Ceiling-Mount 360, 2000 sq. ft. 32kHz with Ambient White ODCRA-000 Hard-Ceiling Raceway Adapter Kit White ODCCG-000 Protective Cage for Ceiling-Mount s Ceiling-Mount s 1.40 (35.6 mm) ø 4.53 (115.1 mm) 1.40 (35.6 mm) ø 4.53 (115.1 mm) ODC05-U, ODC10-U ODC20-U or visit us at: 6
8 Infrared s Ceiling Mount s SPECIFICATIOS & FEATURES IFRARED CEILIG MOUT OCCUPACY SESORS Ideal for use in small offices, general work areas, closets, and other small areas in commercial facilities. Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, longterm performance. Built-in Circadian Calendar Provides 4-week learning period to establish trends that serve as the basis for automatic operation. In peak occupancy periods the sensor remains in high-sensitivity mode and in low occupancy periods it switches to economy mode. Manual Delayed-OFF time settings of 8, 16, & 32 minutes. Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes. Preserves all automatic and manual settings during power outages. Choice of coverage patterns to suits a variety of applications. Small, unobtrusive size (4.5" diameter) blends in with any décor. Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit contains Adapter Base and rotate and lock Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box. OPTIOAL PERFORMACE FEATURES For Models with -IRW Suffix Ambient light override option prevents lights from turning O when there is ample natural light. Secondary Relay Single- Pole Double-Throw (SPDT), rated V AC/DC, three-wire isolated relay. Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection. STADARDS & CERTIFICATIOS CUL/US ODC04-I0W Infrared Ceiling-Mount (For use with Leviton Power Pack) Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital selfadjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton s to Cat. o. ODP20 Power Pack (purchased separately). See page 10 for Power Pack information. COLOR CATALOG UMBER DESCRIPTIO COVERAGE Infrared Ceiling-Mount s White ODC04-I0W Infrared Ceiling-Mount 360, 450 sq. ft. Infrared Ceiling-Mount White ODC04-IRW with Ambient 360, 450 sq. ft. White ODCRA-000 Hard-Ceiling Raceway Adapter Kit White ODCCG-000 Protective Cage for Ceiling-Mount s 1.40 (35.6 mm) ø 4.53 (115.1 mm) 7 ODC04-I or visit us at:
9 Multi-Tech. s SPECIFICATIOS & FEATURES MULTI-TECH WALL-MOUT OCCUPACY SESORS Ideal for conference rooms, stair-wells, open areas, storage rooms and classrooms. Also ideal for corner mounting in a variety of applications. Ultrasonic sensing for maximum range and sensitivity combined with Passive Infrared (PIR) sensing to prevent false triggering from air conditioning and corridor activity. Adjustable swivel neck rotates 80 vertically and 60 horizontally Can be used for ceiling or wall mounting. Self-adjusting settings continuously analyze and adjust sensitivity, timer operation, and air current compensation. Automatic dual-mode operation adjusts to either economy or high-sensitivity mode based on actual occupancy patterns. Built-in Circadian Calendar Provides 4-week learning period to establish trends that serve as the basis for automatic operation. In peak occupancy periods the sensor remains in high-sensitivity mode and in low occupancy periods it switches to economy mode. Manual Delayed-OFF time settings of 8, 16, & 32 minutes. Self-Adjusting Delayed-OFF time interval settings for 4 to 100 minutes. on-volatile memory preserves all automatic & manual settings during power outages. Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post. OPTIOAL PERFORMACE FEATURES For Models with -MRW Suffix Ambient light override option prevents lights from turning O when there is ample natural light. Secondary Relay Single- Pole Double-Throw (SPDT), rated V AC/DC, three-wire isolated relay. Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection. ø 3.63 (92.2 mm) STADARDS & CERTIFICATIOS CUL/US ODW12-M0W Multi-Technology Wall-Mount (For use with Leviton Power Pack) Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital self-adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton s to Cat. o. ODP20 Power Pack (purchased separately). See page 10 for Power Pack information. COLOR CATALOG UMBER DESCRIPTIO COVERAGE OPERATIG FREQUECY Multi-Technology Wall-Mount White ODW12-M0W Multi-Tech Wall-Mount 110, 1200 sq. ft. 32kHz White ODW12-MRW Multi-Tech Wall-Mount 110, 1200 sq. ft. 32kHz with Ambient Multi-Tech Wall-Mount s 3.72 (94.5 mm) ODW12-M 2.73 (69.3 mm) 5.29 (134.4 mm) 6.58 (167.1 mm) or visit us at: 8
10 Infrared s Wide-View and High-Bay, Wall Mount Sensors SPECIFICATIOS & FEATURES IFRARED WALL MOUT OCCUPACY SESORS ODWWV-I: Ideal for rooms with pendant fixtures. Also ideal for corner mounting in a variety of applications. ODWHB-I: Ideal for monitoring long, narrow spaces. Also ideal for corner mounting in a variety of applications. Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation. Adjustable swivel neck rotates 80 vertically and 60 horizontally Can be used for ceiling or wall mounting. Automatic dual-mode operation adjusts to either economy or high-sensitivity mode based on actual occupancy patterns for maximum energy savings. Built-in Circadian Calendar Provides 4-week learning period where sensor establishes trends that serve as the basis for automatic operation. Manual Delayed-OFF time settings with 8-second test mode. Self-Adjusting Delayed-OFF time interval settings for 4 to 100 minutes. on-volatile memory preserves all automatic and manual settings during power outages. Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post. OPTIOAL PERFORMACE FEATURES For Models with -IRW Suffix Ambient light override option prevents lights from turning O when there is ample natural light. Secondary Relay Single- Pole Double-Throw (SPDT), rated V AC/DC, three-wire isolated relay. Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection. ODWWV-I0W Infrared Wide-View and High-Bay Wall Mount s (For use with Leviton Power Pack) Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital selfadjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton s to Cat. o. ODP20 Power Pack (purchased separately). See page 10 for Power Pack information. COLOR CATALOG UMBER DESCRIPTIO COVERAGE Infrared Wide-View s White ODWWV-I0W Infrared Wide-View Wall-Mount 110, 2500 sq. ft. Infrared Wide-View Wall-Mount White ODWWV-IRW with Ambient 110, 2500 sq. ft. Infrared High-Bay s White ODWHB-I0W Infrared High-Bay Wall-Mount 120 ft, 14 ft. 30 ft. height White ODWHB-IRW Infrared High-Bay Wall-Mount 120 ft, 14 ft. wide with 30 ft. height ø 3.63 (92.2 mm) STADARDS & CERTIFICATIOS CUL/US (94.5 mm) ODWWV-I, ODWHB-I 2.73 (69.3 mm) 5.29 (134.4 mm) 6.58 (167.1 mm) or visit us at:
11 Power Packs SPECIFICATIOS & FEATURES POWER PACK ADD-A-RELAY IPPLE ADAPTER STADARDS & CERTIFICATIOS CUL/US For use with: ODC20-M, ODC10- M, ODC05-M, ODC20-U, ODC10-U, ODC05-U, ODC04-I, ODW12-M, ODWWV-I and ODWHB-I. Self-contained power supply for occupancy sensors & switching relay for lighting loads. Provides 24V DC 100 ma nominal, full-wave rectified and filtered power for occupancy sensors and Add-A-Relay units. Available in 120VAC, 230VAC, 277VAC and 347VAC versions with relay contacts rated for 13 amps incandescent or 20 amps lighting ballast loads. Compact size and light weight allows easy mounting through knockout in junction box (from either inside or inside the box) with a simple twist-on nut. Expands Power Pack load capacity by functioning as a supplementary relay. Provides ability to switch loads in different voltage systems (For example, switching 120V incandescent loads in a 277V fluorescent system and vice versa). Compatible with electronic ballasts. Same compact size and mounting features as Power Pack. Power Packs for s (For use with Leviton s listed on pages 5 9) Leviton Power Pack units contain both a 24V DC power supply for s and a 13 Amp relay for switching incandescent or ballast lighting loads. Add- A-Relay units can be used to expand the control capability. Compact, lightweight Power Pack and Add-A-Relay Units are easily mounted in a junction box knock-out hole. DESCRIPTIO CATALOG POWER RELAY COTROL POWER SUPPLY UMBER IPUT RATIG IPUT OUTPUT Power Packs for s Black, Power Pack, 120V ODP V AC 60Hz 13 Amps Incandescent 20 A mps Fluorescent 5mA, 24V DC 100mA, 24V DC Black, Power Pack, 230V ODP V AC 50 & 60Hz 20 Amps Fluorescent 5mA, 24V DC 100mA, 24V DC Black, Power Pack, 277V ODP V AC 60Hz 20 Amps Fluorescent 5mA, 24V DC 100mA, 24V DC Black, Power Pack, 347V ODP V AC 60Hz 15 Amps Fluorescent 5mA, 24V DC 100mA, 24V DC Black, Add-A-Relay Unit ODA mA, 24V DC DESCRIPTIO Power Pack Adapter Low-Voltage ipple Adapter with 1/2" Lock ut for Power Pack and Add-A-Relay units Simplifies the connection of any OD-series Occupancy Sensor to the low-voltage side of a Power Pack mounted inside a fluorescent ballast cavity. 1/2" conduit lock nut included. CATALOG UMBER ODPA Power Pack Capacity Guide One Leviton Power Pack will supply power for a combination of up to 3 devices: 3 sensors (Multi-Tech, PIR or Ultrasonic), 2 sensors and 1 Add-A Relay, 1 sensor and 2 Add-A-Relays, or any combination listed in the chart below. UMBER OF OCCUPACY SESORS UMBER OF ADD-A-RELAYS PERMITTED PERMITTED TO BE WIRED TO POWER PACK PERMITTED TO BE WIRED TO POWER PACK ODP20 Power Packs for s 1.38 (35.1 mm) 2.35 (59.7 mm) 3.66 (93.0 mm) ODP20, ODP15, ODA or visit us at: 10
12 Outdoor Motion Sensors SPECIFICATIOS & FEATURES PROFESSIOAL SERIES OUTDOOR PIR MOTIO SESORS STADARDS & CERTIFICATIOS UL CSA Listed Ideal for a wide range of commercial/industrial settings including parking areas, storage facilities, warehouses, loading docks, marina, garages, walkways, campus grounds, meat lockers, walk-in refrigerators/freezers and outbuildings. Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes. Adjustable sensitivity and immunity to RFI signals reduces false triggers. Ambient light override prevents lights from turning O when there is ample natural light. Provides Automatic, Test and Continuous Modes Test mode simulates automatic operation with short delayed-off time for ease of making adjustments. Continuos mode enables manual override for constant lights O operation (when used with standard O/OFF switch). Outdoor Motion Sensors Surge suppression minimizes likelihood of damage due to electrical surges. Temperature compensation feature ensures uniform performance in extreme hot or cold weather and during temperature fluctuations. Sensor neck adjustment allows accurate area monitoring: 110 vertical, 180 horizontal, 110 rotational. PS200-1FW Outdoor Motion Sensors Passive Infrared (PIR) outdoor motion sensor provide outstanding value in security lighting, convenience, safety and energy savings for a wide range of commercial and residential applications. COLOR CATALOG UMBER DESCRIPTIO COVERAGE RATIG Outdoor Motion Sensors White PS200-10W Professional Series Outdoor 200 Incandescent: 120V PIR Motion Sensor Brown PS200-10B Professional Series Outdoor 200 Incandescent: 120V PIR Motion Sensor White PS200-1FW Professional Series Outdoor 200 Incandescent: 120V PIR Motion Sensor with Dual Floodlights Brown PS200-1FB Professional Series Outdoor 200 Incandescent: 120V PIR Motion Sensor with Dual Floodlights White PS110-10W Professional Series Outdoor 110 Incandescent: 120V PIR Motion Sensor Brown PS110-10B Professional Series Outdoor 110 Incandescent: 120V PIR Motion Sensor White PS110-1FW Professional Series Outdoor 110 Incandescent: 120V PIR Motion Sensor with Dual Floodlights Brown PS110-1FB Professional Series Outdoor 110 Incandescent: 120V PIR Motion Sensor with Dual Floodlights 4.50 (114.3 mm) 2.48 (63.0 mm) 9.16 (232.7 mm) 5.36 (136.1 mm) 11 PS or visit us at:
Energy Management Products
Energy Management Products INDEX LevNet RF Wireless Self-Powered Solutions... 106 Occupancy Sensors... 112 Outdoor Motion Sensors... 131 EZ-MAX Plus Relay Control Panels... 133 GreenMAX Relay Control Panels...
More informationCeiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1
Occupancy and Vacancy Sensors ENERLITES offers a wide variety of lighting sensors. They are designed to bring convenience to your life and business while helping to reduce energy consumption in commercial,
More informationDual Relay Multi-Technology Wall Switch Occupancy Sensors
Dual Relay Multi-Technology Wall Switch Occupancy Sensors The OSSMD line of dual relay multi-technology Decora style wall switch occupancy sensors features several models to provide automatic lighting
More informationSensor Product Guide. Smart Sensing Control Solutions
Sensor Product Guide Smart Sensing Control Solutions Service and Support During Every Step of the Process. Only Leviton has the service and support to help you create a lighting control system that does
More informationTable of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5
Sensor Buying Guide Table of Contents Sensor Models 2 Advantages of Sensors 3 FAQs 4-5 Occupancy and Vacancy Sensors, which provide automatic switching of lighting and motor loads, are fast becoming a
More informationPSC-ID-x-CM Series Ceiling Mount Occupancy Sensor
TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor
More informationMini Product Guide.
Mini Product Guide www.acuitybrands.com/sensorswitch Better Performance Through Advanced Technology 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor
More informationTechnology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2
Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared
More informationArrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations
Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s sensors and dimmers are cost -effective
More informationArrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations
Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s s and dimmers are cost -effective
More informationIllumaTech Innovations
IllumaTech Innovations An Innovative New Family of Smooth, Slide Bar and Rotary Decora-Style Dimmers and Fan Speed Controls with Preset and Non-Preset Models IllumaTech Innovations Innovative lighting
More informationDual Technology Wall Mounted Occupancy Sensor. Manual & Specification
Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION
More informationProduct Bulletin for Decora Rocker Slide Controls
Product Bulletin for Decora Rocker Slide Controls Decora Rocker Slide Controls Application Leviton Decora Rocker Slide s provide smooth, slide-action, full-range dimming for incandescent, dimmable LEDs,
More informationCS1200 WHT Pir Ceiling Mount Occupancy Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Area Coverage Field of View Load Type
More informationNever forget to turn the lights off again. Motion Sensors
Never forget to turn the lights off again. Motion Sensors by Why use motion sensors? Motion Sensors Everyone knows that you can save energy by turning off lights when they re not being used. Even so, sometimes
More informationDual Technology Wall Switch Occupancy Sensor. Manual & Specification
Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION
More informationLighting and Fan Speed Controls
Lighting and Fan Speed ontrols Smart Dimmer System -1 Decorator Touch Dimmers -2 Decorator Slide Dimmers -3 Rotary Dimmers -4 Rotary Dimmers Replacement Knobs -5 Toggle Dimmers -6 Architectural Dimmers
More informationInterior Control Solutions
Interior Control Solutions Passive Infrared (PIR) Technology PIR sensors use a semiconductor detector to sense movement of heat emitted from the human body Sensors respond when a person moves from one
More informationSENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1
SENSORS ENERLITES offers a wide variety of Occupancy and Vacancy sensor models that can monitor virtually any area within a building. We cover the spectrum of technologies with our passive infrared, basic
More informationH-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared
H-MOSS Occupancy and Vacancy Sensors H-MoSS Hubbell Motion Sensing Switches Tomorrow s Technology Today! Adaptive Technology Dual Technology Ultrasonic Technology for Today s Needs Dual Technology H-MOSS
More informationv3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature
DT-300 v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...25
More informationHUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004
HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 EPA Green Lights A L L Y USE OF THIS LOGO DOES NOT IMPLY EPA ENDORSEMENT APRIL 2008 www.nsiindustries.com E-mail: nsi@nsiindustries.com Fax:
More information2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.
2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 1 800 681-9590 F. 418 681-7393 E. info@cristalcontrols.com cristalcontrols.com TM Index Quick Selection...3-4 Which Technology to use...4 Retrofit
More informationLighting Control Strategies. to meet code requirements save energy and improve building performance
Lighting Control Strategies to meet code requirements save energy and improve building performance 1 Lighting Control Strategies Agenda Why Lighting Control Manual Light Reduction Scheduling Occupancy
More informationVersatile wall switch sensors maximize payback and simplify code compliance
Versatile wall switch sensors maximize payback and simplify code compliance Commercial Wall Switch Occupancy Sensors MANUAL-ON MULTI-WAY NIGHTLIGHT Achieve the best energy savings for every wall switch
More informationA. This Section includes the following lighting control devices:
SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationRZI06, RZE06, RZI10, RZM10
Vizia-RF Scene Capable s Vizia-RF Scene Capable s are part of Leviton s Vizia-RF Wireless Home Control System. The system combines the popular Vizia family lighting devices with Z-Wave awardwinning RF-based
More informationInstallation Instructions
DT-300 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features Specifications Voltage................18-28VDC/VAC, half wave rectified AC Current Consumption...............................43mA
More informationIN2 Lighting Control Devices
Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Lighting Control Devices Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals
More informationInfrared Wall Mount Occupancy Sensor
LOS-WI LOS-WI-1 02.01.06 Infrared Wall Mount Occupancy Sensor The LOS-WI wall-mounted passive infrared sensor is used in spaces with pendant fixtures, ceiling fans, or high ceilings (more than 12 feet).
More informationReduce lighting energy costs with controls
Reduce lighting energy costs with controls Reduce energy costs. Support sustainability Get control of your lighting. Upgrading lighting systems to next-generation lighting technologies can deliver energy
More informationMotion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels
MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load
More informationA. This Section includes the following lighting control devices:
Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More informationCONTENTS SENSOR SWITCH
FOCUS ON LIGHTING CONTROL With each product or new technology we develop, our objective is to continually achieve greater energy savings with outstanding user convenience. Our particular focus on lighting
More information1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.
PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 REFERENCES... 2 1.4 DEFINITIONS... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 3 1.7 COORDINATION... 3 1.8 DELIVERY, STORAGE, AND
More informationXET-20 Series 20 Amp Emergency Lighting Control Device
XET-20 Series 20 Amp Emergency Lighting Control Device The Exitronix XET-20 Emergency Lighting Control Device allows the use of auxiliary generator or inverter power on switched fixtures in power failure
More informationLIGHTING CONTROL DEVICES
SECTION - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationSECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS
SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS PART - 1 GENERAL 1 SYSTEM DESCRIPTION A. The distributed lighting control system as specified herein shall be comprised
More informationSECTION LIGHTING CONTROLS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationENERGY EFFICIENCY EXPERTS
ENERGY EFFICIENCY EXPERTS Sensors maximize energy savings by ensuring that lights are turned off or to a lower level when spaces are unoccupied or adequate daylight exists. WattStopper s sensors provide
More informationNational Grid Small Business Program Rebate Manual
National Grid Small Business Program Rebate Manual Rebate Manual Munro Distributing has prepared this manual to aid you and your clients in taking advantage of available rebate programs offered by National
More information0ACDT2000MV Ultasonic/Infared Occ Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 0ACDT2000MV Ultasonic/Infared Occ Sensor Eaton Lighting Catalog Number 0ACDT2000MV Manufacturer Eaton Lighting Description
More informationSpecifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950
1 Specifications Occupancy/Vacancy Sensors CSI 26.09.23. ASHRAE 90.1-2010 AIA Division 16 Section 16950 1. PART 1 - General 1.1 Overview 1.1.1 Provide Occupancy/Vacancy sensors as shown on the plans and
More informationH-MOSS Occupancy Sensors Control Units and Add-A-Relay
Control Units and Add-A-Relay Control Units Hubbell CD series control units are required for use with Hubbell ATD, ATU, ATP, and PIR series ceiling and wall mount occupancy sensors. The control units provide
More informationDHL-LP-LED Low Profile LED Linear High/Low Bay
Job Information Type: Catalog #: Project: Comments: Prepared by: WARRANTY WARRANTY YEAR TEN INCLUDES LABOR ALLOWANCE 2 65W/90W Version 23.81 2 135W Version For 4 dimensions see pg 2 23.81 23.81 23.81 12.6
More informationMANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level
More informationUBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 27 05 05 Communication Rooms Design Guidelines 2.13 1.2 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations Electrical
More informationResidential Occupancy & Vacancy Sensors
Eaton s Wiring Devices Occupancy & vacancy sensors Residential Occupancy & Vacancy Sensors Simple and affordable solutions for energy savings and convenience Eaton s residential occupancy & vacancy sensors
More informationCeiling PIR HS presence detector. Product Guide. Overview. Features
Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high
More informationEast Central College
SECTION 260923 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationThe Power To Supply... All Your Electrical Products
ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions
More informationPOWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.
POWER YOUR ENERGY EFFICIENCY PROGRAMS with proven lighting controls designed to be better. CAPTURE ENERGY SAVINGS FOR YOUR CUSTOMERS AND GROW YOUR BUSINESS WITH PROVEN LIGHTING CONTROLS. Legrand s popular
More informationDIMMING WASP Occupancy and Daylight Sensor
DIMMING WASP Occupancy and Daylight Sensor www.hubbell-automation.com Lighting Control Has Never Been More Essential Energy conservation initiatives, ever-evolving lighting codes and LED technology are
More informationApplied Lighting Controls
Better Buildings By Design 2010 Applied Lighting Controls Steven Mesh, LC, IESNA Senior Lighting Program Coordinator Pacific Energy Center (Pacific Gas & Electric) 851 Howard Street, San Francisco, CA
More informationThe Power To Supply... All Your Electrical Products
May 2016 ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and
More informationSECTION LIGHTING CONTROL DEVICES
SECTION 16145 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationGE LightSweep Lighting Control System Guideform Specification
GE Lighting Control GE LightSweep Lighting Control System Guideform Specification If you have any questions at all regarding this specification, please contact your local GE Lighting Control representative,
More informationSection D. H-MOSS Occupancy Sensors Index. Wall Switches. Wall and Ceiling Mount. Sensors. Residential and Vacancy. Sensors
Section D Index Product Sensor Technology Page Smart Technologies for Smart Buildings... D-2 Energy Savings with Occupancy Sensors... D-3 Wall Switches Features and Benefits... D-4 Wall Switches with Adaptive
More informationAdvanced Lighting Control for High Building Performance
www.sylvania.com Advanced Lighting Control for High Building Performance Better Buildings by Design Kandice Castellino February 2014 Burlington, VT Why Advanced Lighting Controls? Controls Greater energy
More informationLPCMPIRM65 & LPCMPIRDSI65
Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual
More informationVive PowPak Fixture Controls
Vive 369918g 1 03.12.18 The PowPak wireless fixture control is a radio-frequency (RF) device that controls either the Lutron EcoSystem or 0 10 V- electronic fluorescent ballasts and LED drivers (depending
More informationDIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM
DIVISION 26 ELECTRICAL SECTION 26 09 26 PART 1 GENERAL 1.01 DESCRIPTION A. The intent of this set of specifications is to provide a complete, functional, intelligent, lowvoltage lighting control system
More informationSensors and Detectors
12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental
More informationPrinceton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors
Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors 1. SUMMARY AND BACKGROUND: Princeton Joint Unified School District located in Princeton
More informationInfrared Ceiling Mount Sensor
Infrared Ceiling Mount Sensor LOS-CI Series LOS-CI- 0.0.06 The LOS-CI Series ceiling-mount passive infrared sensors can integrate into Lutron systems or function as standalone controls using a Lutron power
More informationLS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors
Datasheet Ceiling mount occupancy sensors Overview The CM Series of ceiling mount occupancy sensors provide a range sensor solutions for applications with finished ceilings (e.g., ceiling tiles, sheetrock,
More informationB. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.
PART 1 GENERAL 1.01 Lighting design: A. Reference UAF Facilities Services Guidelines for Average Illumination Levels. B. It is recognized that these standards are updated irregularly and lighting technology
More informationMovement-based energy control
04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights
More informationDaylighting Control Design and Application Guide
Daylighting Control Design and Application Guide DAYAPPS_1206 Design Guide Introduction Introduction Daylighting controls transform a day lit area into an energy-saving opportunity. The U.S. Environmental
More informationThe Safer Living Collection
The Safer Living Collection T H E S A F E R L I V I N G C O L L E C T I O N Improving Home Safety and Your Bottom Line We ve been leading advocates of electrical safety for over 100 years. Advancements
More information64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).
Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)
More informationInfrared Ceiling Mount Sensor
Infrared Ceiling Mount Sensor 69655c 0.07. The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack. The
More informationEver evolving energy code requirements and the large demand for energy
Ever evolving energy code requirements and the large demand for energy saving products have made lighting control sensors a must-have for building owners and managers. Hubbell Control Solutions introduces
More informationInstallation Instructions
Specifications PW-100 PW-200 PW-100/PW-100-347/PW-200/PW-200-347 v3 Passive Infrared Wall Switch Occupancy Sensor PW-100-347 PW-200-347 Voltages: PW-100 & PW-200................ 120/277VAC, 50/60Hz PW-100-347
More informationLIGHTING CONTROLS
260923 LIGHTING CONTROLS PART 1: GENERAL 1.01 SUMMARY COMMENTS A. CU has developed this lighting control guideline to direct design professionals toward standard solutions that meet the University s performance
More informationPassive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit
Instruction Bulletin 63249-420-418A1 02/2014 Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Commercial Grade with Ground SLSPWD1277C Retain for Future Use INTRODUCTION The Passive Infrared
More informationminiz Quick Start Guide
miniz Quick Start Guide Congratulations on purchasing the miniz Daylight Harvesting Controller. The miniz is designed to be easy to install and configure with a few simple steps. Simplest Install Steps:
More informationPIR OCCUPANCY SWITCHES
PIR OCCUPACY SWITCHES PIR occupancy switches The DAERS range of passive infra-red occupancy switches is designed for the automatic control of lighting, heating, ventilation or air conditioning s. The PIR
More informationMANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately
More informationFROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR
FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR INNOVATION AND RELIABILITY THAT SPANS OVER 120 YEARS.
More informationMANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately
More informationLighting Controls. Energy-Saving Solutions For Efficient Buildings
Lighting Controls Energy-Saving Solutions For Efficient Buildings Honeywell Lighting Controls Deliver Light When You Need It And Energy Savings When You Don t Businesses, schools and government facilities
More informationCommercial Grade Lighting Controls Collection
Product Specifications Commercial Grade Lighting Controls Collection VZI06-1L / VZ00R-1L VZ00R-10 VZE06 VZS15 / VZ0SR-1L VZ0SR-10 KEY PRODUCT FEATURES Efficient construction with consistent form factor,
More informationCode Review TITLE PRESENTED BY POURIA NIKNAM
Code Review TITLE 24-2016 PRESENTED BY POURIA NIKNAM 2 Important Topics Partial-On as per Title 24 Definition and criteria for Daylight Responsive Control Controlled Receptacles Automatic Demand Response
More informationADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR
ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR 5/9/18 Procurement Towson University 8000 York Road Towson, MD 21252-0001 t. 410 704-2171 f. 410 704-8233 Ladies and Gentlemen:
More informationProduct Specifications Dialog Room Controller* (*patent pending)
1 Product Specifications Dialog Room Controller* (*patent pending) 1. GENERAL 1.1. OVERVIEW 1.1.1. Provide a complete stand-alone, decentralized, low voltage, digital lighting control system for classrooms,
More informationEducation Title Solutions
Education Solutions Design Guide Crestron Electronics, Inc. Contents About 1 Design Guide Information 1 Code Standards 2 Classroom 4 Zūm... 4 GLPP... 5 Higher Education Classroom 6 Zūm... 6 GLPAC... 7
More informationAHAC-DT MicroSet dual tech low/line voltage ceiling sensors
s Ceiling sensors description The dual technology sensor s combination of ultrasonic and passive infrared technologies offers the most complete sensing equipment available today. MicroSet self-adjusting
More informationVESICA LINEAR SUSPENDED VES L
PROJECT INFORMATION Project Name Catalog # VESICA LINEAR SUSPENDED APPLICATIONS Office Spaces Conference Rooms Municipal Facilities Medical Facilities Type Date Financial Institutions Retail Spaces Hospitality
More informationShannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow
Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager Yesterday, Today & Tomorrow The Good Old Days: The.59 Cent Solution Simple, Inexpensive, Easy To Operate, Etc. Everybody
More informationMANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level
More informationdesign guide for wireless l i g h t i n g c o n t r o l
design guide for wireless l i g h t i n g c o n t r o l ON OFF system operation radiotouch Fluorescent Fixtures ( With Lutron dimming ballasts) Power RadioTouch Controller RadioTouch Controller Power Power
More informationRDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:
RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation
More informationIP65 High Bay Dual Sense Sensor
IP65 High Bay Dual Sense Sensor TM and, Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High
More informationWherever the best is needed. Sensors for professionals.
Wherever the best is needed. Sensors for professionals. 3 Presence Detectors Motion Detectors (indoor) Power Packs Wallswitches from page 14 from page 4 from page 52 from page 6 IR Quattro HD IR Quattro
More informationIntegrated Classroom Control System. Installation and Operation Manual
Integrated Classroom Control System Installation and Operation Manual 1 Table of Contents Introduction... 3 Installation... 4 Operation... 8 Notes: Daylighting Configuration... 14 Appendix A Open Loop
More informationFixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /
Project name Prepared by Date INDOOR AIRLINK LUTRON Catalog #: ALC/ALCE Part #: 624087/634480 The ALC/ALCE wireless fixture controller is a radio-frequency (RF) device that controls the 0 10V or Lutron
More informationOccupancy Sensor Operation with Lighting Fixtures
Occupancy Sensor Operation with Lighting Fixtures Product: Leviton OSFHU Passive Infrared Fixture Mount High Bay Sensors Article ID: 09222009-BC/AM-01 Date: September 22, 2009 Summary: This article is
More informationPSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor
TECHNICAL SPECIFICATIONS PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor Overview Quad Element PIR sensor 0-10V configurable output: set to 0% (OFF)*, 10%, 25% or 50% dimming Photocell for ambient light
More informationSECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS
SECTION 26 09 23 LIGHTING CONTROL DEVICES AND CONTROL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Remote control lighting relays. 2. Lighting contactors. 3. Switches. 4. Switch plates.
More information