1 Lenel Systems International, Inc Pittsford-Victor Road Pittsford, New York Tel Fax Contents OnGuard 7.1 Resolved Issues 1. Introduction Access Control Actions Alarm Monitoring Archives Badge Types Client Update Communication Server Configuration Editor Database Database Setup DataConduIT DataExchange Digital Video Global I/O Installation Linkage Server MapDesigner Replicator Replication Administration Reports Scheduler System Administration System Management Console Visitor Management Web Area Access Manager... 7 DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
2 1. Introduction This document contains a list of issues that have been resolved in OnGuard 7.1, and is intended as a supplement to the OnGuard 7.1 Release Notes. 2. Access Control A slave reader for a dual reader interface added using the Wizard does not work (OG-29730): This release resolves this issue. The slave reader works as expected when added using the Wizard. 3. Actions The text field of " address" and "Select printer below" are cut off or overlap on the Schedule Report Properties dialog (OG-29985): This release resolves this issue. Text fields display as 4. Alarm Monitoring Max Cardholders reached alarm does not appear in Alarm Monitoring (OG-29670): This release resolves this issue. The Max Cardholders reached alarm appears in Alarm Monitoring as CommonAdministrationStrings.rc has the word Acknowledgment misspelled as Acknowledgement (OG-29710): This release resolves this issue. Acknowledgment is correctly spelled. Alarm Monitoring stops working when performing an alarm acknowledgement (OG-30205): This release resolves this issue. Alarm Monitoring works as When sending Generic Input events, the alarm name is displayed in OnGuard instead of the text that associated with the event (OG-26778): In Alarm Monitoring, when Generic Input events are sent, the associated text now appears for the alarm description instead of only the alarm name. Generic Input events are: Input Alarmed - L_GENERIC_INPUT_ALARMED Input Normal - L_GENERIC_INPUT_NORMAL Input Low Low - L_GENERIC_INPUT_LOW_LOW Input Low - L_GENERIC_INPUT_LOW Input High - L_GENERIC_INPUT_HIGH Input High High - L_GENERIC_INPUT_HIGH_HIGH Alarm Monitoring operation slows after the Display Controller Capacity option is enabled (OG-30059): This release resolves this issue. Alarm Monitoring works as Alarm Monitoring stops working when opening a map with devices in different monitoring zones than what is already opened (OG-30223): This release resolves this issue. Maps open in Alarm Monitoring as Alarm Monitoring does not display receiver account groups (OG-30308): This release resolves this issue. Alarm Monitoring displays receiver accounts in their groups as DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
3 Interior points generate alarms when in Arm Stay Mode (OG-30341): This release resolves this issue. Interior points operate as expected when the system is in Arm Stay Mode. 5. Archives Enabling archive database feature on SQL Server Express does not start Setup Assistant (OG-30203): This release resolves this issue. Setup Assistant starts as expected when the archive database feature in SQL Server Express is enabled. 6. Badge Types "From Cardholder ID" badge types cause issue when adding second active badge (OG-29646): This release resolves this issue. From Cardholder ID badge types work as 7. Client Update Some text is cut off on the Client Update window (OG-29830): This release resolves this issue. The Client Update window displays as 8. Communication Server Chime does not work (OG-30022): This release resolves this issue. Chime works as ILS Lock events stop processing when the communication server temporarily loses database connection (OG-30209): This release resolves this issue. ILS Lock events work as 9. Configuration Editor Custom parameter in connection string could be lost after using Configuration Editor (OG-29875): This release resolves this issue. Custom parameters are saved as 10. Database Send to Print Service Bureau appears in OnGuard (OG-29554): This release resolves this issue. The Send to Print Service Bureau print badges permission has been removed from The Users > Cardholder Permission Group. 11. Database Setup Incorrect value for the Bias offset of the Casablanca/Morocco time zone (OG-30299): This release resolves this issue. The correct value for the Bias offset of the Casablanca/Morocco time zone is now inserted in the dbo.worldtz table of the OnGuard SQL database. DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
4 12. DataConduIT DataConduIT service stops when executing the MoveBadge method after changing the default segment of access panel to another custom segment (OG-29952): This release resolves this issue. The MoveBadge method can be executed successfully after changing the default segment of access panel to another custom segment. 13. DataExchange Badges cannot be added using the Copy Access Level Assignment action when Rollback entire row is enabled (OG-30168): This release resolves this issue. The action works as expected and badges can be added. 14. Digital Video Able to hear audio in mute state after launching video in Alarm Monitoring (OG-30174): This release resolves this issue. Audio is muted in both single view or matrix view. Video Viewer (Browser-based client) title bar color does not extend across for widescreen monitors (OG-30179): This release resolves this issue. The red title bar extends across the display as 15. Global I/O Global I/O does not unmask input groups (OG-30099): This release resolves this issue. The Global I/O masks and unmasks as 16. Installation Black box appears in Client Update command prompt (OG-29758): This release resolves this issue. Client Update functions as DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
5 17. Linkage Server Linkage Server stops working when processing temporary access levels (OG-29921): This release resolves this issue. The Linkage Server works as Search on cardholder custom field UDFEMP.EMPLID causes error with report (OG-29935): This release resolves this issue. The report can be previewed when searched on Cardholder custom field. 18. MapDesigner Certain device names/font combinations cause MapDesigner to stop working (OG-29708): This release resolves this issue. MapDesigner works as 19. Replicator System Table Download wipes out Badge Type to Badge Layout association (OG-29787): This release resolves this issue. The Verify Badge layout appears as Hardware Transaction Failed error occurs in Replicator when uploading several hardware transactions (add/deletes) from an Enterprise Master/Region (OG-30030): This release resolves this issue. Replicator works as Site Publication Server Transactions will appear stuck in Awaiting Processing at Destination status if source transaction is deleted from BDG2TRN (OG-30149): This release resolves this issue. Transactions are processed as Site Publication Server does not download Segment Groups as additional segments (OG-30355): This release resolves this issue. Segment groups download as additional segments as 20. Replication Administration The System-Wide Cardholder Search wizard in Replication Administration is too small to fit the enlarged Cardholder form (HPQC# 6617): This release resolves this issue. The System-Wide Cardholder Search wizard now resizes as Server ordering does not work in Replication Administration (HPQC# 6894): This release resolves this issue. Server ordering works as MESSAGE_BROKER_HOST option not listed in the Object Type drop-down in Replication Administration (OG-29638): This release resolves this issue. The Message Broker Host is listed in Object Type and can be used to filter transactions. PTZ Tour failed to run at the first added time (OG-29968): This release resolves this issue. PTZ tour starts as DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
6 21. Reports User Transaction Log report does not display the correct records based on date time filter (OG-30031): This release resolves this issue. The User Transaction log report displays the correct records as User does not receive the record count warning if OnGuard database uses non-default database password (OG-30251): This release resolves this issue. The user receives the record count warning as expected if there are more than five (5) records. The timezone Never has incomplete display in Timezones Report (OG-30346): This release resolves this issue. The timezone Never displays as 22. Scheduler Recurring actions with specified end date do not work on last day (OG-30342): This release resolves this issue. Recurring actions work as 23. System Administration Auto disarm option stops working when an intrusion mask group with an LNL-CK in it is modified (HPQC# 6957): This release resolves this issue. Intrusion mask groups can be modified and the auto disarm option works as The same IP address can be used for the primary and secondary connections for a DES server (OG-29632): This release resolves this issue. The same IP address cannot be used for the primary and secondary IP connections. Controls in the Badge Template Assignment Wizard do not fit on the screen (OG-29699): This release resolves this issue. Controls on all tabs display as Baud rate cannot be set when configuring an Intercom panel (OG-29901): This release resolves this issue. The baud rate can be set when configuring a Commend GE300/GE800 Intercom device or a Generic Intercom device. Hardware timezone is clipped in NGP Panels and Hardware Panels report (OG-29903): This release resolves this issue. Content displays as No support for Authenticated Reader on the LNL-2210 and LNL-3300-M5 (OG-29957): This release resolves this issue. Authenticated readers can be properly configured for LNL and LNL-3300-M5 panels, in addition to the LNL-2220 and LNL-3300 panels. CASI 20 DI inputs in range cannot be used with custom alarms (OG-30180): This release resolves this issue. CASI 20 DI inputs can be used with custom alarms as Pair Master settings is still checked even if 8RP reader is set as Paired Reader (OG-30210): This release resolves this issue. Pair Master settings is unchecked and disabled when 8RP reader is set as Paired Reader. Panel and Reader wizards are improperly blocked on an Enterprise Master (OG-30234): This release resolves this issue. Panels and readers can be added as Unexpected alarm generated when badge is swiped at reader and Destination Assurance is configured (OG-30264): This release resolves this issue. The correct alarm appears in Alarm Monitoring when a badge is swiped at the reader. DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
7 The maximum number of records (253) has already been added to segment Default Segment message appears when attempting to add records when the timezone max limit is reached (OG-30296): This release resolves this issue. The max number of records message no longer appears when attempting to add records. 24. System Management Console LSM service is displayed in the System Management Console (OG-29703): This release resolves this issue. The LSM service has been removed from the OnGuard Services list in the System Management Console. 25. Visitor Management Cannot add a visit in Visitor Management (OG-30188): This release resolves this issue. Visits can be added as 26. Web Area Access Manager Area Access Manager (Browser-based client) fails to remove Access Level with the error The delete action failed. (OG-30226): This release resolves this issue. The application works as DOC-1013-EN-US (May 2015) 2015 Lenel Systems International, Inc. revision
OnGuard 7.2 Resolved Issues
UTC Fire & Security Americas Corporation, Inc. 1212 Pittsford-Victor Road Pittsford, New York 14534 Tel 866.788.5095 Fax 585.248.9185 www.lenel.com Contents OnGuard 7.2 Resolved Issues 1. Introduction...
More informationCourse Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers
Course Catalogue Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers An evolution of excellence Contact information: UTC Fire & Security Kouterveldstraat
More informationOnGuard Cumulative Hot Fix 3.0 Release Notes
Lenel Systems International, Inc. 1212 Pittsford-Victor Road Pittsford, New York 14534 Tel 585.248.9720 Fax 585.248.9185 www.lenel.com OnGuard 6.4.500 Cumulative Hot Fix 3.0 Release Notes Table of Contents
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev2 Copyright 2011 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationOpenDevice Events Guide
OpenDevice Events Guide 2016 United Lenel is a part of UTC Climate, Controls & Security, a unit of United July 19, 2016 1 Table of Contents Open Device Events... 3 Granted Access Events... 8 Denied Events...
More informationAvigilon Control Center 5 System Integration Guide
Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with
More informationDIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004
Manual Number AV-137622 Revision - A.1 September 3, 2004 DIAMOND II DARM Delayed Alarm Reporting/Masking 791 Park of Commerce Boulevard Suite 100 Boca Raton Florida 33487 www.ge-security.com DIAMOND II
More informationGetting Started with Live Exceptions
Getting Started with Live Exceptions Live Exceptions provides alarm reporting by identifying problems that include delay, errors, failures, security, or configuration changes. The Live Exceptions Browser
More informationC&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0
C&K Software What s New Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0 C&K Software PC-based receiver with monitoring features Windows-based Remote programming software (Commander
More informationMilestone SMI Intrepid II Perimeter Module 1.1 User s Manual
Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone
More informationAvigilon Control Center 5 System Integration Guide
Avigilon Control Center 5 System Integration Guide with Hirsch Velocity INT-HIRSCH-B-Rev1 2012 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Velocity INT-HIRSCH-A-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this
More informationMonitoring Operator Guide. Access Control Manager Software Version
Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED
More informationLenel OnGuard Access Control Module (ACM) Integration User Manual V3.1
Lenel OnGuard Access Control Module (ACM) Integration User Manual V3.1 Target Audience for this Document This document is aimed at system users and describes the integration between Lenel OnGuard and Milestone.
More informationD3D Wi-Fi GSM Smart Alarm System -User Manual
D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM
More informationAvigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0
Avigilon System Integration Guide Avigilon Control Center with AMAG Symmetry Security Management System 7.0 2013-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, HDSM, HIGH
More informationAccess CONTROL. MANAGEMENT Software
Software Guide Access CONTROL MANAGEMENT Software Engineered to meet today s demands and tomorrow s challenges, Keyscan s System VII software delivers unique features to provide an access control solution
More informationUD-VMS510i. Surveillance Management Center
Surveillance Management Center Introduction VMS510i is a flexible, scalable, high reliable and powerful central management system. Client-Server Architecture, Integrating with multiple surveillance systems.
More informationCardax System Comparison
System Comparison Hardware FT Series 5 Syst Com 131102 Syst Com 131102 2 Contents 1. Introduction... 5 2. System Diagrams... 7 3. Hardware Comparison... 10 4. Comparison... 11 Syst Com 131102 3 Syst Com
More informationAvigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager
Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2017, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACC, AVIGILON CONTROL CENTER,
More informationAvigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager
Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, AVIGILON CONTROL CENTER,
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationAvigilon Control Center 5 System Integration Guide
Avigilon Control Center 5 System Integration Guide with Lenel Facility Commander Wnx INT-FCWNX-A-Rev1 2010 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationMonitor Alarms and Events
This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,
More informationGMS GRAPHICAL MANAGEMENT SYSTEM
GMS GRAPHICAL MANAGEMENT SYSTEM 1 GMS Security management system for multi-site organizations. PACOM Graphical Management System (GMS) is the modular client-server application that integrates all of PACOM
More informationD-Link Central Management System
D-Link Central Management System This seamless management of digital video, audio and data is a powerful solution for large scale installations The D-Link Central Management System is a powerful system
More informationArchitectural and Engineering Specification for a Security Management System. StarNet 2
Architectural and Engineering Specification for a Security Management System StarNet 2 Jan 2, 2018 Page 1 of 12 AE-S2-IN-R1-EN-01/18 This document is intended to provide performance specifications and
More informationAlarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9
Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,
More informationChapter. Configuring Genetec Omnicast. Version 4.7 SR1. Configuring Third-Party Programs. SightLogix, Inc
Configuring Genetec Omnicast Version 4.7 SR1 2 Chapter Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS programs, which display video, GPS coordinates,
More informationSystem Galaxy Quick Guide
System Galaxy Quick Guide CONFIGURATION AND OPERATION Integrating CCTV with System Galaxy JAN 2019 SG 11.1.0.2 System Galaxy Quick Guide For CCTV Integration Configuration & Operation Information in this
More informationSetting up and Managing Alarms in McAfee ESM 10.x
McAfee SIEM Alarms Setting up and Managing Alarms in McAfee ESM 10.x Introduction McAfee SIEM provides the ability to send alarms on a multitude of conditions. These alarms allow for users to be notified
More informationFortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B
FortiNAC Lightspeed Single Sign-On Integration Version: 8.x Date: 8/29/2018 Rev: B FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET KNOWLEDGE BASE
More informationSimplex Panel Interface Guide
Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.
More informationThis technical update applies to Pro-Watch Software Release 3.5 and later.
Technical Update Pro-Watch Software Intercom Product Support Product Versions This technical update applies to Pro-Watch Software Release 3.5 and later. Overview Intercom systems consist of master stations,
More informationi-vu CCN 4.0 Owner s Guide
i-vu CCN 4.0 Owner s Guide CARRIER CORPORAION 2007 A member of the United echnologies Corporation family. Stock symbol UX. 11-808-377-01 07/07 able of Contents ACCESSING YOUR SYSEM... 3 YOUR SYSEM DEAILS...
More informationChapter. Configuring DVTEL. DVTel Latitude version 3.5. DVTel ISOC version Configuring Third-Party Programs
Configuring DVTEL DVTel Latitude version 3.5 DVTel ISOC version 5.3.1.15 2 Chapter Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS programs, which
More informationRaytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0
Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0 Table of Contents 1 INTRODUCTION... 3 1.1 OVERVIEW... 3 1.2 SOFTWARE COMPONENTS...
More informationGrandstream Networks, Inc. GDS3710 Input/output Connection Guide
Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering and Connecting the GDS3710... 5 Power and Data PINs... 5 Alarm In and Alarm Out PINs... 6 DETECT AND
More informationManaging Network Alarms and Events
10 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active
More informationChapter. Configuring OnSSI NetDVMS. OnSSI NetDVMS versions 5.x through 6.5g. OnSSI NetDVMS Ocularis. Configuring Third-Party Programs
Configuring OnSSI NetDVMS OnSSI NetDVMS versions 5.x through 6.5g OnSSI NetDVMS Ocularis 2 Chapter Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS
More informationChapter. Configuring Cisco VSMS. Versions 5.1, 6.0. Configuring Third-Party Programs. SightLogix, Inc
Versions 5.1, 6.0 2 Chapter Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS programs, which display video, GPS coordinates, and alarm and other
More informationLighting Xpert Insight User Manual
Lighting Xpert Insight User Manual Table of Contents 1 About This Document... 3 1.1 Key Terms... 3 1.2 Related Fifth Light Documentation... 3 2 Lighting Xpert Insight Overview... 4 2.1 Key Features...
More informationP2000 Security Management System Express Edition Version 3.14 SP5
Code No. LIT-1900971 Issued February 2, 2018 P2000 Security Management System Express Edition Version 3.14 SP5 Description The Johnson Controls P2000 Security Management System (SMS) represents the latest
More informationI/A Series A 2 Software FoxAlert Alarm Manager
Product Specifications I/A Series A 2 Software FoxAlert Alarm Manager PSS 21S-2B2 B4 Current Alarms Display Most Recent Alarms Display Summary Displays By Status Alarm History Display An Extensive Collection
More informationManaging Network Alarms and Events
9 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active
More informationION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document
70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,
More informationMonitor Alarms and Events
What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Which Events Are Supported?, page 5 Set Alarm and Event Management Preferences, page 5 Interpret Event and Alarm
More informationX.90 Access Control System
X.90 Access Control System ACX provides a comprehensive Access Control System and Time Attendance, which is the highest security standard in the world industry. ACX product range includes door access panel,
More informationChallenger10 Administrators Manual
Challenger10 Administrators Manual P/N MAADMN-TS1016 REV 01 ISS 18FEB13 Copyright Trademarks and patents Manufacturer Agency compliance Contact information 2013 UTC Fire & Security. All rights reserved.
More informationPro-Watch Software Suite. Architect and Engineering Specifications. January 9, 2002 Revision 3.4
Architect and Engineering Specifications Revision 3.4 SECTION 13800 BUILDING AUTOMATION AND CONTROL Part 1 GENERAL 1.0.1. GENERAL 1.0.2. REFERENCES 1.0.3. DEFINITIONS 1.0.4. SYSTEM DESCRIPTIONS 1.0.5.
More informationConfiguring IndigoVision Control Center. Configuring IndigoVision Control Center
Control Center Prerequisite: IndigoVision Control Center 4.7 build 25 or later Sightlogix Firmware: 5.4.6829 or later Control Center Note: This functionality is only available if you have administrator
More informationHikCentral Specification. HikCentral V1.1.1 Specification
HikCentral V1.1.1 Specification Introduction HikCentral is a flexible, scalable, reliable and powerful central video system. HikCentral provides central management, information sharing, convenient connection
More informationProcidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010
Procidia iware AlarmWorX32 AlarmWorX32 Viewer Siemens Protection AG 2008. notice All / Copyright rights reserved. notice Introduction / Contents Procidia iware is an operator interface software designed
More informationVMD Guide for MP-980 Cameras
Configuration Guide XX206-10-00 VMD Guide for MP-980 Cameras Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788 Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116 24-Hour Technical
More informationP2000 and Metasys System Integration
P2000 and Metasys System Integration Product Bulletin Code No. LIT-12011781 Software Release 3.12 Issued June 20, 2013 Supersedes April 20, 2012 Refer to the QuickLIT Web site for the most up-to-date version
More informationAvigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1
Avigilon Control Center 5 System Integration Guide with STENTOFON AlphaCom INT-STENTOFON-C-Rev1 2013 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted
More informationAlarm setup and definitions in Cisco Unified Serviceability
Alarm setup and definitions in Cisco Unified Serviceability Set up Cisco Unified IM and Presence Serviceability alarms, page 1 Alarm setup and update for a service, page 2 Alarm definitions and user-defined
More informationCARD ACCESS CONTROL SYSTEM
SECTION 13851 CARD ACCESS CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested, integrated proximity access control system, to operate on a proximity principle where
More informationAdemco Vista Alarm Panel
System Galaxy Quick Guide CONFIGURATION AND OPERATION Ademco Vista Alarm Panel JAN 2018 SG 10.5.6 System Galaxy Quick Guide For Ademco Vista Panel Configuration & Operation 2nd edition JAN 2018 Information
More informationVMD Guide for MP-980 Cameras
Configuration Guide XX206-10-01 VMD Guide for MP-980 Cameras Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788 Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116 24-Hour Technical
More informationCentroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!
Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com
More informationMultiSite Manager. Setup Guide
MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...
More informationAdvisor Advanced Mobile Application User Manual
Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5
More informationBOSCH GV4 Alarm Panel
System Galaxy Quick Guide CONFIGURATION AND OPERATION BOSCH GV4 Alarm Panel SG 10.2 (or later) NOV 2012 This is a Galaxy Product Interface Guide. Information in this document is subject to change without
More informationTable of Contents. i-vu CCN Standard 4.2
i-vu CCN Standard 4.2 Owner's Guide CARRIER CORPORATION 2009 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-381-01 7/13/2009 Table of Contents Accessing your
More informationTable of Contents. Appendix A Special Characters 31
Table of Contents Introduction 2 Section 1: General System Operation 3 1.1 Getting to Know Your System... 3 1.2 How to Arm... 4 1.3 Alternate Arming Methods... 5 1.4 Disarming... 6 1.5 Alarm Memory...
More informationBefore you install ProSeries Express Edition software for network use
Before you install ProSeries Express Edition software for network use The following pages describe system requirements and other information you need to know before installing ProSeries Express Edition
More informationIntegration Test Plan
Integration Test Plan Terminus Security Prepared by: Kai Chan Stephen Krenzel John O Meara Version: 1.0 1 Contents 1 Introduction 3 1.1 Purpose.................................. 3 1.2 Scope...................................
More informationOracle Communications Performance Intelligence Center
Oracle Communications Performance Intelligence Center System Alarms Guide Release 10.2.1 E77506-01 June 2017 1 Oracle Communications Performance Intelligence Center System Alarms Guide, Release 10.2.1
More informationIon Gateway Cellular Gateway and Wireless Sensors
Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Picture Perfect 4 INT-PP4-A-Rev1 Copyright 2012 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationCompleteView Alarm Client User Manual. CompleteView Version 4.6.1
CompleteView Alarm Client User Manual CompleteView Version 4.6.1 Table of Contents Introduction... 1 Overview...2 System Requirements...2 Configuration... 3 Starting the Alarm Client...3 Menus...3 File
More informationAlarm Hot Backup Manager can use InTouch, Galaxy, or Galaxy_ as alarm providers when configuring an alarm Hot Backup Pair.
Tech Note 925 Configuring Alarm Hot Backup Using Galaxy Provider All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for
More informationGE Security SAPPHIRE Pro
GE Security SAPPHIRE Pro Delayed Alarm Reporting and Masking User Guide Delayed Alarm Reporting and Masking User Guide 12 AV-137621:Revision-B / October 5, 2004 Delayed Alarm Reporting and Masking Delayed
More informationGeneral Surveillance Management Centre. DSS is a flexible, scalable, high reliable and powerful central management system.
General Surveillance Management Centre Introduction DSS is a flexible, scalable, high reliable and powerful central management system. Client-Server Architecture, Integrating with multiple surveillance
More informationSection 5. Control Systems
Section 5 There are several Kaleidescape options available for controlling a Premier system. Kaleidescape Remote Kaleidescape App for ipad Kaleidescape Child Remote Browser interface control panels A Premiere
More informationSmart Combiners Installation Guide. For Obvius A89DC-08 sensor modules
For Obvius A89DC-08 sensor modules Introduction Large roof and ground arrays connect the panels into stings that are merged together in combiner boxes. Each string will typically consist of 10-15 panels
More informationSensor Cloud User Manual
Sensor Cloud User Manual Table of Contents DEVICES TAB 4 1. DEVICE LIST 4 2. EXPAND ALL 4 3. EXPAND 4 4. STATUS 4 5. DEVICE 4 6. NAME 5 7. MONITORING INTERVAL 5 8. LAST ACTIVITY 5 9. VIEW 5 10. DELETE
More informationVersion 1.03 January-2002 USER S MANUAL
Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...
More informationBlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.
BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.3, October 2017 Copyright 2017 BlackBerry Limited. All Rights Reserved.
More informationThe system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.
0BThe System The Security Management System should be capable of Controlling and Monitoring Access through the doors, Monitor and control Inputs and Outputs, include an Integrated Video Badging, Integrate
More informationHoneywell Enterprise Alpha version 5.86
Honeywell DVM version 200.2.5788 2 Chapter Honeywell Enterprise Alpha version 5.86 Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS programs, which
More informationVMD Guide for V960 Series Cameras
Configuration Guide XX206-40-01 VMD Guide for V960 Series Cameras Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788 Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116 24-Hour Technical
More informationS6 Titan Security System. Wi-Fi and 3G GSM
S6 Titan Security System Wi-Fi and 3G GSM Version 1 - Apr 2018 Table of Contents Introduction 1 Self Monitoring 1 GSM SIM Card and Land Line 1 Free Mobile App (iphone / Android) 1 Pre-Programmed Accessories
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More informationGSM WIRELESS ALARM SYSTEM Model: GSM-0308W
GSM WIRELESS ALARM SYSTEM Model: GSM-0308W Table of Contents Application..... 3 Instructions. 4 Installation Diagram....5 Device Design... 5 Technical Parameter....6 Setup Instruction.6 1 Administrator
More information7:00AM 1:00AM ET 7:00 AM 12:00AM ET
Agent Guide Homebase intouch Customer Service (877) NRT-HELP Help@HomebaseinTouch.com M-F: 7:00AM 1:00AM ET Weekends: 7:00 AM 12:00AM ET Version 1.1 October 2012 Contents What is Homebase intouch?... 4
More informationOpenDevice United Technologies Corporation. Lenel is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.
OpenDevice The OnGuard OAAP program allows third party manufacturers (OAAP partners) to interface their products with the OnGuard platform. OpenDevice is one of the API groups supported by OnGuard. OpenDevice
More informationManual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel
Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel
More informationFacility Commander Complete, Integrated Command and Control
Facility Commander Complete, Integrated Command and Control 2.0 Facility Commander Complete, integrated command and control Securing your business facilities requires multiple systems, often from different
More informationHoneywell Total Connect Remote Services
Honeywell Total Connect Remote Services Basic User Guide With Honeywell Total Connect Remote Services, you can stay connected and in control of your home or business whenever you want, wherever you are.
More informationP2000 and Metasys System Integration
P2000 and Metasys System Integration Product Bulletin Code No. LIT-12012141 Software Release 3.14 SP1 Issued June 23, 2017 The Johnson Controls P2000 Security Management System supports the integration
More information1 Introduction Data transmission Compatibility IPS Analytics configuration... 3
Configuration Instruction Integration of IPS Video Analytics on Axis Cameras with a Milestone XProtect Video Management System Contents 1 Introduction... 1 2 Data transmission... 2 3 Compatibility... 3
More informationAccess Professional Edition. The flexible access control system that grows with your business.
Access Professional Edition The flexible access control system that grows with your business www.boschsecurity.com Access Professional Edition: the ideal solution for easy and intuitive access management
More informationAK-CS On Board Guide
MAKING MODERN LIVING POSSIBLE AK-CS On Board Guide electronic controls & sensors About this guide The AK-CS On Board guide highlights the use of the RMT tool, allowing remote software management. Consult
More informationDell and Lenel Grow Globally, Together
technology Dell and Lenel Grow Globally, Together CASE STUDY OnGuard Delivers Flexible Capabilities and Ability to Handle Eventualities That We Couldn t Even Yet Predict. At age 19, Michael Dell founded
More informationBosch TCU Integration Module Administrator's Guide
Bosch TCU Integration Module 1.0 - Administrator's Guide 10 Dec 2008 Rev 1.2 Table of Contents 1 Overview... 3 1.1 Compatibility...3 1.2 References...3 2 Installation... 4 3 Configuration... 5 3.1 System
More informationAccess Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants
2008 Video Security Consultants Brought to You by Presented by Part 3 of 4 A1 Part 3 of 4 Taking a Hard Look at Software The essential function of an electronic access control system (EACS) is to control
More information