BOP Management System Information
|
|
- Bryan Sims
- 5 years ago
- Views:
Transcription
1 BOP Management System Information V 1.0 June 10, 2015
2 Table of Contents Display Panel... 3 Power Disconnect... 5 Pneumatic Override (Optional)... 7 Foot Pedal Transducer (Optional)... 9 BOP Ram Sensor LED Indicator Warning Station Pressure Sensor Commissioning, Testing and Training
3 Display Panel Install Time Rig Status Requirements QUICK FACTS Minutes Racked, Moving or Operating Location selected by Rig Manager. 12 VDC - 24 VDC power Description of Function: The panel is the main display, wireless receiver and control module for the Rigsmart BOP Management System. Sensor transmissions are received through the panel and clearly displayed for the operator. The panel is where BOP logic is loaded, and is the main controller for dumping air and alarming events. Location: The panel is located in the doghouse (or supervisor specified area) and can be mounted to any fixed surface. It is designed for outdoor use in all weather conditions. Rig Requirements: Rig Status The panel is installed while the rig is racked. A 12 VDC - 24 VDC power source from the rig to the Rigsmart power disconnect is required, and technicians must have access to the doghouse (or other specified mounting location). Crew Responsibilities The supervisor should provide a location preference for the panel. Time Required minutes is required for panel mounting and setup. Antenna and configuration requirements may vary according to the chosen panel location. 3
4 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* Display Panel Data Sheet Overview The main display, wireless receiver and control module for the Rigsmart BOP Management System. Sensor transmissions are received through this panel and are clearly displayed for the operator. The Panel is also where BOP logic is loaded, and is the main controller for dumping air before a collision occurs, and alarming the crew. The panel is typically mounted in the doghouse. Operating time 100% (continuous duty) Voltage type VDC, 7.5A normal operating range (can accept VDC) Operating temperature -40 C to +60 C Operating Frequency Range MHz in North America MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection Woodhead, bulgin or amphenol Mounting options Bolt on bracket Hazardous locations Class 1 Division 2 Ex na IIB+H2 T4 Certified to: IEC CAN/CSA E :02 Environmental Ingress Protection IP67 Application Drilling rigs, Service rigs, Snubbing units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 4
5 Power Disconnect Install Time Rig Status Requirements QUICK FACTS 15 Minutes Racked, Moving, Operating Location selected by Supervisor. 24 VDC power Description of Function: The Power Disconnect is the main on/off switch for the Rigsmart System. The box requires a 24 VDC power source, either provided directly from the customer or from a power converter box provided by Rigsmart Systems. Location: The box is located in the doghouse (or other specified location) and can be mounted to any fixed surface. It is designed for outdoor use in all weather conditions. Rig Requirements: Rig Status The panel is installed while the rig is racked. A 24 VDC power source from the rig to the Rigsmart power disconnect is required, and technicians must have access to the doghouse. Crew Responsibilities The Supervisor should provide a location preference for the power disconnect. Time Required 15 minutes is required for mounting and setup. Configuration requirements may vary according to the chosen panel location. 5
6 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* Power Supply Data Sheet Overview The Rigsmart Power Supply Box runs on a standard 120 VAC 240 VAC source provided by the customer, and outputs 24 VDC for the use of the Rigsmart System components. Operating time 100% (continuous duty) Voltage type Input: VAC Output: 24 VDC Operating temperature -40 C to +60 C Construction - 16 gauge steel body and cover - Welded seams without knockouts or holes - Seamless poured-in place gasket - Door includes a quarter turn slot for added safety Connection Bulgin Mounting options Bolt on bracket Hazardous locations Ex II 3 G Ex na nc IIC T4 Gc TÜV 11 ATEX X Ex na nc IIC T4 Gc IECEx TUN X Environmental Ingress Protection IP67 Application Drilling rigs, Service rigs, Snubbing units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 6
7 Pneumatic Override (Optional) Description of Function: Install Time Rig Status Requirements QUICK FACTS 1 Hour Racked Access to the air or electrical system A pneumatic or electric throttle control box is connected to the service rig, drilling rig or snubbing unit power pack. When the rams are closed, the system will kill throttle to prevent the rig from pulling into the closed rams. The component is paired with a throttle override pedal for bypass. Location: The pneumatic or electric throttle control box is connected to the service rig, drilling rig or snubbing unit power pack. It is used to interrupt the throttle airline or electric control line. Rig Requirements: Rig Status - The rig should be racked, with the air or power de-energized. The Rigsmart technician requires access to the air or electric throttle system. Crew Responsibilities - Some minor assistance from the crew may be required in testing operations. Time Required - Can be installed in approximately 1 hour. 7
8 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* Pneumatic Override Data Sheet Overview The Rigsmart Pneumatic override will cut the operators throttle in the event of an alarm. The override can be bypassed and throttle restored at a reduced rate if the operator actuates the wireless foot pedal. Once the alarm condition clears, the override releases control of the operators throttle. Operating time 100% (continuous duty) Voltage type 12 or 24 VDC Operating temperature -40 C to +60 C Operating Frequency Range MHz in North America MHz in Europe Material Hot compression molded fiberglass reinforced polyester (thermoset) Connection ¼ NPT Mounting options N/A Hazardous locations All internal components are rated for Class1 Division 2 Environmental Ingress Protection IP67 Application Snubbing Units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 8
9 Foot Pedal Transducer (Optional) Description of Function: Install Time Rig Status Requirements QUICK FACTS N/A N/A N/A The Wireless Foot Pedal provides a way for the operator to move the string at a reduced speed when an alarm condition is present. The device is wireless so it can be easily moved to wherever the operator is standing. Location: Normally on the driller s platform but the device can be placed anywhere, due to its wireless nature. Rig Requirements: Rig Status No special access is required. Crew Responsibilities - Some minor assistance from the crew may be required in testing operations. Time Required N/A 9
10 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* Foot Pedal Transducer Data Sheet Overview The Rigsmart Wireless foot pedal will restore limited throttle to the operator during an alarm condition. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range MHz in North America MHz in Europe Material Body material Ultramid 8333G Hi- Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options Foot pedal to be placed near operator Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E :02 Environmental Ingress Protection IP67 Application Snubbing Units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 10
11 BOP Ram Sensor Install Time Rig Status Requirements QUICK FACTS 30 Minutes Racked, deenergized BOP access and custom bracket Description of Function: The BOP Ram Sensors detect whether or not the rams on the BOP stack are in the open or closed position. The sensors come in sets of two (one for each ram side) and work in conjunction. The transducer is made up of a proximity sensor that can detect when a metal object is close to it or not. The panel identifies that the ram (and which side) has been closed. Location: The sensors are mounted on the very end of the ram. When the ram is open, the end of the ram shaft is positioned ¼ away from the sensor s pickup. Rig Requirements: Rig Status - The monitored equipment needs to function after installation, for testing purposes. Crew Responsibilities - Some minor assistance from the crew may be required in testing operations, and creating a mount location. Time Required - Sensors can be installed in approximately 1 hour, once the mounts are fabricated. 11
12 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* BOP Ram Sensor Data Sheet Overview The Rigsmart BOP Ram Sensor is a proximity device which detects the presence of the BOP polish rod. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range MHz in North America MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options Brackets fabricated for various BOP s Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E :02 Environmental Ingress Protection IP67 Application Snubbing units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 12
13 LED Indicator Install Time Rig Status Requirements QUICK FACTS N/A N/A N/A Description of Function: The LED Display is a visual indicator for the ram sensors. Each LED is paired to a specific set of rams, and will flash either red (for closed ram status) or green (for open), as indicated by the sensors. Location: The sensors are magnetically mounted, and can be placed wherever the operator has a direct line of sight to the device. Rig Requirements: Rig Status N/A Crew Responsibilities N/A Time Required N/A 13
14 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* LED Indicator Data Sheet Overview The Rigsmart LED indicator visually displays the BOP status. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range MHz in North America MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options Magnetic mounting bracket Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E :02 Environmental Ingress Protection IP67 Application Snubbing units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 14
15 Warning Station Install Time Rig Status Requirements QUICK FACTS hours Racked Access to doghouse and de-energize electric system Description of Function: The Warning Station receives status from the display panel on the BOP and accumulator system. Red indicates a closed ram, green indicates an open ram, and yellow indicates low accumulator pressure. The warning station also has two horns that sound different audible alarms, based on the status of the rams or accumulator. Location: The device is mounted on top the doghouse, or other supervisor specified area. Rig Requirements: The electric system needs to be de-energized, and access to the doghouse is required. Rig Status Racked Crew Responsibilities Assistance with the installation location may be required. Time Required hours 15
16 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* Warning Station Data Sheet Overview The Rigsmart Warning station can be equipped with ram closed strobe, ram open strobe, accumulator pressure low strobe and alarm horns for BOP closure and accumulator low pressure. Operating time 100% (continuous duty) Voltage type VDC Operating temperature -40 C to +60 C Construction - 16 gauge steel body and cover - Welded seams without knockouts or holes - Seamless poured-in place gasket - Door includes a quarter turn slot for added safety Connection Certified electrical connection Mounting options Custom for alarm station location Hazardous locations Alarm station is typically not mounted in the classified zone. Environmental Ingress Protection IP67 Application Drilling rigs, Service rigs, Snubbing units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 16
17 Pressure Sensor Install Time Rig Status Requirements QUICK FACTS 30 minutes Racked Hammer Union or Nipple Description of Function: A wireless component which measures fluid or gas pressure directly off of pipes and transmits the reading back to the main display panel. Location: Can be connected to any ½ NPT port or configured to any custom connection. A Hammer Union or ½ port is required. Rig Requirements: Rig Status Racked Crew Responsibilities Provide assistance with installation location. Time Required 30 minutes 17
18 *Information subject to change without notice. Consult the factory for the most current data and part numbers.* Pressure Sensor Data Sheet Overview A wireless component which measures fluid pressure directly off of pipes and transmits the reading back to the main display panel. They are available in 100, 3,000, 5,000, 10,000, and 15,000 PSI models. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range MHz in North America MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options 1/4 NPT, 1/2 NPT, hammer union, custom Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E :02 Environmental Ingress Protection IP67 Application Drilling Rigs, Service Rigs, and Snubbing Units Rigsmart Systems, Inc St. Edmonton, AB T6L 4B2 Ph: info@rigsmart.com 18
19 Commissioning, Testing and Training Install Time Rig Status Requirements QUICK FACTS Various Operating Driller, Rig Manager, operator, supervisor and any personnel requiring training Description of Function: Commissioning, testing and training are considered the most important part of the installation procedure. Calibrations are vital to optimal system performance, and each component must be proven to interact with the panel software as it was designed, for each specific unit. It is Rigsmart s goal is to train operators and crews to use and maintain their own systems safely and effectively. Collision and zone management limits are set and adjusted with the rig crew s input and cooperation. Post installation service is available 24/7, but through adequate training many service related issues can be avoided. Rig Requirements: Rig Status The rig must be operational and able to provide a full function test. Crew Responsibilities A driller or Rig Manager is required to operate the different functions of the rig such as raising or lowing the blocks, link-tilt or moving the top drive. The crew will also be required to provide input on collision limits for the system. Time Required- Testing each component can take up to 30 minutes per component. Commissioning the full system may take up to 4 hours, depending on the situation. Training the Rig Manager and crew may take anywhere between one hour of instruction to several days of operational-drilling tutorials. 19
Dependable Solutions for Gas Detection
Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April
More informationClampOn DSP Corrosion- Erosion Monitor
ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion- Erosion Monitor DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion-Erosion Monitor The patented ClampOn DSP Corrosion-Erosion
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationGasAlertMicroClip X3 Specifications
GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationINSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup
115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP66 Weight: 5.5 kg single AC unit 7.0 kg four way AC unit Marking: Installation Requirements 1) Introduction The A131 high
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More informationyour dust explosion protection experts
your dust explosion protection experts HMI Overview Camera Systems Pag. 2 Remote I/O Barriers & Isolators Pag. 3 Purge Pag. 3 Plugs & Receptacles Lighting Pag. 5 Control Stations Pag. 6 Terminal Boxes
More informationGas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector
Gas Detection RAE Systems by Honeywell Battery-Powered Wireless Gas Detector Battery-Powered Wireless Gas Detector The RAE Systems by Honeywell gas detection monitor is a key building block of the intelligent
More informationINSTRUCTION MANUAL A131 High Level Audible Warning System
Weight: 1.5kg single AC unit 2.9kg four way AC unit Marking: 3) Installation Requirements 1) Introduction The A131 high level audible warning system is an effective wide area warning alarm system and can
More information805QS Pressure Switch-Transmitter
805QS Pressure Switch-Transmitter These instructions provide information for installation, process connection, n, electrical connection, operation and maintenance of the 805QS pressure switch-transmitter.
More informationLabkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
More informationMaglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY
Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Main features Event recording up to 32 Gb removable microsd card (only
More information25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL
25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low
More informationTrusted worldwide since 1989 INTRINSICALLY SAFE RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high
More information120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable
120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224
More informationINTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400
Pressure Transducer / Transmitter AST4400 Overview The AST4400 is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and best price-toperformance ratio in
More informationIsco 3700ZR Sampler. Manual Set
Isco 3700ZR Sampler Manual Set Assembly #60-2744-045 Copyright 2001. All rights reserved, Teledyne Isco Revision D, December 14, 2012 This set of manuals supports the Isco 3700ZR Refrigerated Sampler.
More informationINTRODUCTION / TABLE OF CONTENTS
1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features
More informationINSTRUMENTATION AND CONTROL DEVICES FOR HVAC
PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE
More informationSECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationDescription. Applications
CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationDTS Light fittings for explosive atmospheres
DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light
More informationVanguard. Toxic & combustible gas detector
Toxic & combustible gas detector T C D 5 0 - B - 0 1 Capability Overview Wireless Capability WirelessHART communication 7.2 IEC 62591 compatible Integrated HART terminals Adjustable update rate Quick Mount
More informationBeacon 800 Gas Monitor Operator s Manual
Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be
More informationPANELBOARD PROTECTION ON A GLOBAL SCALE
PANELBOARD PROTECTION ON A GLOBAL SCALE INTRODUCTION WHY? No matter what environment, location or power requirement, Appleton panelboards have you and your facility covered. From a petrochemical plant
More informationEx Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder
Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder Load Systems International 2666 Boul du Park-Technologique Québec QC G1P 4S6 Canada www.loadsystems.com
More informationPURGE/PRESSURIZATION SYSTEM
PROCESS AUTOMATION PURGE/PRESSURIZATION SYSTEM DATA SHEETS Systems ( Series) 2001A: Class I Volumes 2 ft 3 and Class II Volumes 10 ft 3...3 2001B: Class II Volumes 50 ft 3...7 2001C: Class II Volumes 250
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationYOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.
Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters
More informationHOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper
HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous
More informationofficial distributor of Newson Gale Ltd.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationClampOn DSP Pig Detector
ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Pig Detector DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Pig Detector A Pig Detector is a tool that is always used in pigging operations.
More informationOverview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.
Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless
More informationBeacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08
Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationMBCE-110/230FR Flame Sensor Module
MBCE-1001 FEBRAURY 6, 2017 MBCE-110/230FR Flame Sensor Module exida FMEDA SIL2 SEE NOTE 1 ON PAGE 4 DESCRIPTION The MBCE-110/230FR modules provide visual indication and electrical outputs that signal the
More informationGIRTON CABINET WASHER MODEL 794A
DESCRIPTION GIRTON CABINET WASHER MODEL 794A The washer shall be a Girton Model 794A Cabinet Type Pressure Washer constructed of type-304 stainless steel, utilizing a reciprocating header spray system.
More informationOMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments
OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March
More informationIndustrial Signalling
Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range
More informationPOSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING
POSITIONERS ELECTRO-PNEUMATIC INTELLIGENCE CONTROLS SERIES 6A FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS CELEBRATING The High Performance Company Y E A R S INTELLIGENCE Series 6A Intelligent Electro-Pneumatic
More informationFisher LCP100 Local Control Panel
Instruction Manual LCP100 Local Control Panel Fisher LCP100 Local Control Panel Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Hazardous Area Classifications
More informationINTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401
Pressure Transducer / Transmitter AST4401 Overview The AST4401 is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and best price-toperformance ratio in
More informationCommercial and Light Industrial Fire Alarm Control Panel
FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground
More informationSU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM
model The Supervisor 2000-SM is our thinnest barrier-free turnstile. Its compact form is well suited for applications where space is at a premium. COMMON APPLICATIONS Employee and Visitor Access Control
More informationQuick Start Guide For the
A Leader in Level Measurement Quick Start Guide For the Universal IV Lite and Universal IV Pro Model Transmitters 2-Wire RF Admittance / Capacitance Level Measurement System with HART Protocol For Assistance
More informationDesign Manual Installation Operation Maintenance
Design Manual Installation Operation Maintenance Model GT824 NOVA-Sensor ELITE Oxygen Monitoring Detector 70115 23282 Mill Creek Drive, Suite 215 Laguna Hills, CA 92653 USA +1.949.583.1857 Phone +1.949.340.3343
More informationINTRINSICALLY SAFE LIGHTING RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting
More informationSENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification
This sample specification is for a duress only stand-alone SCAN system using SR series receivers with zone-within-a-zone and graphic display. SECTION 17 DURESS SYSTEM PART 1.00 - GENERAL 1.01 DESCRIPTION
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations
More informationSurvey of electrical equipment installed in hazardous areas on tankers
(June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on
More informationSAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508
Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection
More informationCompetence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust
Competence for Safety Within the scope of the creation of the explosion protection document (mandatory for the operator according to ATEX 137), production locations must be divided into zones depending
More informationTELECOMMUNICATION. Telecommunication. Wireless Phone
TELECOMMUNICATION Telecommunication Wireless Phone Talkback System CCTV PAGA TV Distribution LAN / WAN System 25 Telecommunication Telecommunication projects in the Oil & Gas industry are often large,
More informationS5000 Gas Monitor. GMS5000.com
S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON
More informationRig Protector. Multipoint Critical Gas Detection and Monitoring System
Rig Protector Multipoint Critical Gas Detection and Monitoring System Rig Protection Device Protecting Personnel from Hazardous Gases RC Systems has engineered and manufactured industrial electronic products
More informationWE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS
WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationCrouse-Hinds Enclosures. High performance, high reliability enclosures for global applications
Crouse-Hinds Enclosures High performance, high reliability enclosures for global applications Crouse-Hinds Enclosures High Performance, high reliability enclosures for global applications Eaton s Crouse-Hinds
More informationRosemount 2051T In-line Pressure Transmitter
February 2017 T In-line Pressure Transmitter T In-line Wireless Pressure Transmitter Configuration 4 20 ma HART with Selectable HART (1) Lower Power with Selectable HART (1) FOUNDATION Fieldbus PROFIBUS
More informationDräger X-zone 5500 Area Monitoring
Dräger X-zone 5500 Area Monitoring State-of-the-art area monitoring the Dräger X-zone 5500 in combination with the Dräger X-am 5000, 5100 or 5600 gas detection instruments can be used for the measurement
More informationPROTÉGÉ ZM SINGLE GAS MONITOR
PROTÉGÉ ZM SINGLE GAS MONITOR KEEPING YOUR WORKFORCE SAFE JUST GOT EASIER. PROTÉGÉ ZM SINGLE GAS MONITOR. Scott Safety announces the introduction of the Protégé ZM Single Gas Monitor an easy-to-use, zero-maintenance
More informationRosemount 3490 Series
Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall
More informationOPTIMUM APPLIED SYSTEMS,
OPTIMUM APPLIED SYSTEMS, INC. HEAT COMPUTER 3500 DSL TECHNICAL SPECIFICATIONS HC 3500 GENERAL SYSTEM DESCRIPTION The Heat Computer is a computerized building heating control system that utilizes sensors
More informationFeatures. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign
Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationPhotobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide
Photobeam 5000 ISC-FPB-W60QS, ISC-FPB-W20QS, ISC-FPB-W200QS en Installation and Operation Guide Photobeam 5000 Table of Contents en 3 Table of contents Introduction 4. About documentation 4.2 Bosch Security
More informationpower HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets
Harness the power of collaborative innovation MANET-SCHULTZ OF AMERICA S P E C I A L I S T S I N E L E C T R O M A N E T I C E V I CES Magnet-Schultz of America, Inc. 401 Plaza rive Engineered for safety
More informationWall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects
763.422.2600 Spec-00042 J763.422.2211 Wall-Mount Preferred-Cutout s Hoffman WATERSHED Wall-Mount s Wall-Mount Preferred-Cutout s Hoffman WATERSHED Wall-Mount s WATERSHED Enclosure, Type 4X INDUSTRY STANDARDS
More informationAO Annunciator Module
General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,
More informationMSM400 Ultrasonic Suspended Solids Monitoring and Control System
Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either
More informationSWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS
A full spectrum of sensing and signaling Celebrating 50 Years of Excellence products for protection, detection, and safety 1957 In Safety and Sensing 2007 SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES
More informationOILFIELD INSTRUMENTATION & CONTROL SYSTEMS. Rig Control Products Ltd
OILFIELD INSTRUMENTATION & CONTROL SYSTEMS Rig Control Products Ltd Rig Control Products (RCP) have an outstanding reputation for delivering high quality innovative oilfield control equipment and engineering
More informationFireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel
PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to
More informationWAVE SEQUENCER DELIVERS:
The WAVE Sequencer employs state-of-the-art wireless technology to shut down and isolate vulnerable electrical components during local thunderstorms. The Sequencer receives digitally encoded signals from
More informationD3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION
D3000 Installation and Operating Manual SAFETY Always wear the required Personal Protective Equipment (such as safety glasses, gloves, face shields, and aprons) when potentially exposed to any hazardous
More informationOil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches
Oil & Gas Oil & Gas Control every move Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches Barksdale Oil and Gas - The Challenge today Oil & Gas Today Worldwide
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationDETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station
DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station Operator s Installation and Instruction Manual Also covers the V2-DV2 dual strobe and A1-DV2 Horn units DETCON, Inc. 4500
More informationColorMax Cyclone Cleaning Kit
Instruction Sheet P/N 637 0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description See
More informationULTIMA X5000. MSAX5000.com
ULTIMA X5000 MSAX5000.com WE KNOW YOU RE TIRED OF... NEEDING TO DISCONNECT POWER BEFORE CHANGING A SENSOR REMEMBERING HOW TO CALIBRATE THIS THING HAVING TO PULL SO MUCH WIRE AT EVERY GAS DETECTOR INSTALLATION...
More informationW1/B, O, W2/E, Y1, Y2, G. Gas or electric. Wireless, 915MHz, proprietary protocol. Up to 100 feet 24VAC, 2.4VA. Molded plastic
Wireless COMF TTM Made in the USA Application Installation Manual Model WCT-32 The WCT-32 is a 7-day programmable, battery powered thermostat that communicates via an F wireless data link to a relay control
More informationEngineering Specifications for HXV Closed Circuit Hybrid Cooling Tower
Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower 1.0 Closed Circuit Hybrid Cooling Tower 1.1 General: Furnish and install, as shown on the plans, factory-assembled closed circuit
More informationINFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY
INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous
More informationDräger X-zone 5500 Area Monitoring
Dräger X-zone 5500 Area Monitoring Dräger's X-zone 5500 brings a safer, more effective way to monitor hazardous gases--reinventing area monitoring. In combination with the Dräger X-am 5000, 5100, or 5600
More informationRosemount 2051T In-Line Pressure Transmitter
Rosemount 2051T In-Line Pressure Transmitter 2051T In-Line Wireless Pressure Transmitter Configuration Transmitter Output Code 4-20 ma HART 2051 A 2051 with Selectable HART (1) Lower Power 2051 2051 with
More informationLTFX Electric Tank Immersion Heaters Installation Instructions
LTFX Electric Tank Immersion Heaters Installation Instructions 1 PN403-5 161-049178-101 March 2017 LTFX Electric Tank Immersion Heater Installation Instructions General The Chromalox Electric Tank Immersion
More informationErik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories
Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION
More informationSYSTEMS PRODUCT OVERVIEW
PROCESS AUTOMATION THE LEADERS IN PURGING TECHNOLOGY PURGE AND PRESSURIZATION SYSTEMS PRODUCT OVERVIEW SERIES 6000 SERIES 5000Q SERIES 3000 SERIES 1000 MAKE YOUR AREA SAFE ANYWHERE IN THE WORLD GLOBAL
More informationSeries 155. Mass Flow Computers TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,
More informationGS01 (wireless) Detection of flammable gases and vapours
GS01 (wireless) Detection of flammable gases and vapours The GS01 is a wireless infrared gas transmitter for continuous monitoring of flammable hydrocarbon gases and vapours in the oil and gas industry
More informationstandards: standards:
INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD
More informationSteam Humidifier Models 1150 and 1160
Humidifier Steam Humidifier Models 1150 and 1160 Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS PRODUCT OVERVIEW.............................. 3 Materials
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationMustang Vaporizer. Installation, Operation & Maintenance MV
Mustang Vaporizer Installation, Operation & Maintenance MV TABLE OF CONTENTS Safety Warnings 3 Product Features 4 Technical Specifications 5 Product Dimensions & Parts 6 Electrical Wiring Diagrams 8 Installation
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More information