Start display at page:

Download "Karman Vortex Flow Meter KSL-5/10/30/50LN"

Transcription

1 Karman ortex Flow Meter KSL-5/1/3/5LN

2

3 Karman ortex System Flow Sensor KSL-5L/KSL-1L/KSL-3L/KSL-5L Features s a sensor for monitoring the cooling water of equipment, a cumulative total of 6, units have been delivered to leading semiconductor and LCD equipment manufactures in the world. Measures and displays the flow rate and temperature. llows use with high temperature water of 9 C. nalog output larm output Digital display Electric wiring Digital display larm display LED FLOW TEMP SET Setting switch switch switch sheath... Power supply lack... GND White... output ( to 1 DC or 4 to 2 m or pulse) Orange... output ( to 1 DC or 4 to 2 m) Yellow... alarm Green... alarm Gray lue Spare cores rown WM2276: This is a cable with no terminal processing 9 core/.2 mm 2 /5 mm). GND should be used as a common ground wire for all other signaling lines including power supply. Dimensions Front view * Plan view 3 19 FLOW TEMP 68 SET Countersunk hole for 4-M4 (hexagon socket head cap screw) dapter for piping Rc3/8 screw (both sides) dapter for piping size Rc3/8 sm 92 Side view *1 Width SUS 98 R1/ The value varies depending on the adapter type. 5 Model KSL-5L KSL-1L KSL-3L KSL-5L *2 Height The size varies depending on the model. *2 4 x 2M4 screw for adapter (hexagon socket head cap screw) 3 Flow direction 3 (Unit: mm)

4 Specifications characteristics Model detection range larm output Maximum operating pressure KSL-5L measurement KSL-1L to 99 C KSL-3L.5 to to 1 5 to 3 7 to 5 to 1, 4 to 2m, Pulse to 1, 4 to 2m Open collector or (flow rate, temperature) 1 MPa (below 1kgf/cm 2 ) KSL-5L Current output (m) 2 12 oltage output () C Normal temperature Fluid temperature mbient temperature Flow direction Power supply Current consumption ccuracy to 9 C to 4 C (Non-freezing) Specified direction 12 DC±5% or 24 DC±1% (factory setting) 3 m max. (7 m max. in 4 to 2 m specification) FS±2.% 4 KSL-5L KSL-1L KSL-3L () Material of body Materials of detectors Material of adapter pplicable fluid Sealing O-ring Coupling of pipings PPS detector: PPS, temperature detector: SUS34 SUS or sm + Ni plating ndustrial water or service water Fluororubber Rc 3/8 or Rc1/2 WM cores/.2 mm 2 /5mm KSL-5L The flow rate characteristics are temperature dependent as shown in the above graph. Caution: To maintain accuracy, secure a straight-pipe length of 7D or more on the upstream side and 5D or more on the downstream side. Moreover, be sure to install valves, branches, gauges, etc. on the downstream side. (D: Diameter. For 5L, D = 4.1 mm; for 1L, D = 5.8 mm; for 3L, D = 1 mm; for 5L, D = 12 mm.) Order format KSL 5L.5 to 5 1L 1.5 to 1 3L 5 to 3 5L 7 to 5 Power supply 12 DC12 24 DC24 Example P* Pulse output DPM DPM connection to 1 4 to 2m to 1 4 to 2m larm dapter Material S SUS sm Ni plating KSL-5L S-3/8 dapter connection port dia. 3/8 1/2 Definition of alarm output and display LED Measurement value larm Higher than the Lower than the Green * The alarm is conductive when the open collector is and non-conductive when it is. * The alarm for the flow rate and that for the temperature can be set independently. * "P" (pulse output) can be specified only for 5L and 3L and cannot be specified for 1L and 5L. * When the output of the flow rate is set to "P" (pulse output), the temperature output is "" or "." n temperature output, the pulse output cannot be selected. (The order format of the output is "P" or "P.") Example: KSL-5L-24-P---S-3/8 * The "DPM " (DPM connection) is a pulse specification for using the external display "DPM " specified by REGL JT. * For 5L, only 1/2 can be specified as the adapter connection port diameter. * To improve the performance, the shape and specifications are subject to change without prior notice. Green

5 Karman ortex System Flow Sensor KSL-8L/KSL-16L Features s a sensor for monitoring the cooling water of equipment, a cumulative total of 6, units have been delivered to leading semiconductor and LED equipment manufactures in the world. Measures and displays the flow rate, temperature, and integrated values. nalog output larm output The digital display is turned depending on the installation status. Digital display Electric wiring switch ntegration switch switch Mode display LED larm display LED... Power supply lack... GND White... output Orange... output Yellow... alarm rown... ntegration alarm Green... alarm lue... ntegration reset Gray... COM (common alarm return) WM2276: This is a cable with no terminal processing (9 core/.2 mm 2 /1 mm). GND should be used as a common ground wire for all other signaling lines including power supply. f COM is specified as the common alarm return in the order format, the return of the flow rate and temperature measurement alarm output is COM. Dimensions Digital display Setting switch Front view 13 (18) * The numerical values in parentheses are dimensions in KSL-16L specifications. Water outlet (41) Water inlet Display panel Side view ody Plan view 57.5 (63) Rc1/2 (Rc1) female thread, both sides nterface cable 4-ø4.5 hole 2 (35) 9 (11) 13 (18) 2 (35) 16 (2.5) Serial number 16 (2.5) 6.5(8) 33 (Unit: mm)

6 Specifications characteristics Model ntegration detection range larm Maximum operating pressure Fluid temperature mbient temperature Flow direction Power supply Current consumption ccuracy Material of body Materials of vibrator pplicable fluid Sealing O-ring Coupling of pipings Weight Note) The KSL-16L has the following accuracies: ccuracy of FS±2% in a range from 2 to 14 ccuracy of FS±5% in a range from 14 to 15 ccuracy of FS±1% in a range from 15 to 16 Order format KSL-8L 1 to 8 Rc 1/2 38g to L to 99 C KSL-16L 2 to 16 to 1 or 4 to 2 m (flow rate, temperature)/pulse (integration) MOS-FET or (flow rate, integration, temperature) 2 1 MPa (below 1kgf/cm 2 ) to 6 C to 4 C (Non-freezing) Specified direction DC12±5% or DC24±1% 3 m max. (7 m max. in 4 to 2 m specification) FS±2.% SUS34 Resin (LCP) ndustrial water or service water Fluororubber Rc 1 WM cores/.2 mm 2 /1mm 5g Current output (m) oltage output () C Normal temperature KSL-8L () KSL-16L The flow rate characteristics are temperature dependent as shown in the above graph. Caution: To maintain accuracy, secure a straight-pipe length of 7D or more on the upstream side and 5D or more on the downstream side. Moreover, be sure to install valves, branches, gauges, etc. on the downstream side. (D: Diameter. For 8L, D = 13.5 mm; for 16L, D = 19. mm.) KSL 8L 1 to 8 16L 2 to 16 Power supply 12 DC12 24 DC24 P Pulse output to 1 4 to 2m larm ntegration Example KSL-8L COM to 1 4 to 2m Common alarm return COM Floating status G Connected to GND Definition of alarm output and display LED Measurement value larm Higher than the Lower than the light out light out * The alarm output uses the common return for the flow rate, integration, and temperature. For the common return, "COM: floating status" or "G: Connected to GND" can be selected. The alarm is conductive when the MOS-FET is and non-conductive when it is. The alarms for flow rate, for integration, and for temperature can be set independently. * When the output of the flow rate is set to "P" (pulse output), the temperature output is "" or "." n temperature output, the pulse output cannot be selected. (The order format of the output is "P" or "P.") Example: KSL-8L-24-P----COM * To improve the performance, the shape and specifications are subject to change without prior notice.

Drain Separator for Vacuum

Drain Separator for Vacuum Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port

More information

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500. Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable. http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display

More information

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001 ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size). http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

General Specifications

General Specifications General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min

More information

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH PERFECT ISOLATION BY MAGNET COUPLING COVERING HIGH TEMP., HIGH PRESS., AND VACUUM APPLICATIONS PRESSURE TIGHT FLAMEPROOF FOR HYDROGEN ATMOSPHERE READY SPRING BALANCED DISPLACER TYPE FS- Series LEVEL SWITCH

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications Water Separator Series The series water separator is installed on the air pressure line to remove water drops in the compressed air. It is suitable for use in cases where "water must be removed, but the

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

Added cooling capacity of 140 W. (air-cooled).

Added cooling capacity of 140 W. (air-cooled). Peltier-Type Chiller Thermo-con Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using the Peltier device. Generates

More information

Noiseless Heater Vacuum Relief Valve

Noiseless Heater Vacuum Relief Valve Noiseless Heater Vacuum Relief Valve -1 Step Type/Structure/Features Please refer to this for structure and feature of Noiseless Heater and Vacuum Relief valve. Step 1 Selection Please look at the ID chart

More information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

Vacuum related component model series variation

Vacuum related component model series variation Vacuum related component model series variation Vacuum related components Vacuum pad Vacuum ejector/vacuum unit VSLF series VSFB Series VSFU Series Series

More information

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type

More information

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W 594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free

More information

Pressure Switches Precautions 1 Be sure to read this before handling.

Pressure Switches Precautions 1 Be sure to read this before handling. Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate

More information

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10 Ionizer Nozzle type Series IZN10 Electrode needle contamination detector Outputs maintenance signal when detects stain or wear of an electrode needle always. Detects optimal maintenance time, reduced labor

More information

AUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS

AUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit AUXG8LRL AUXGLRL UTG-UKYA-W Outdoor unit AOYG8LCA AOYGLCA CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

±6kV ±2.5kV (AS unit, close condition) Conventional Free Air Thermal Current (Ith) 250V AC (COSφ=0.95) 0.15A AC

±6kV ±2.5kV (AS unit, close condition) Conventional Free Air Thermal Current (Ith) 250V AC (COSφ=0.95) 0.15A AC TEST SWITH STT type TEST SWITH High safety and contact reliability lever operation type Test Switch onformity with major standards STT type conforms to IE0- and applies to UL. Open-ircuit prevention Internal

More information

Differential pressure gauge with electrical contact type Model: P650 series

Differential pressure gauge with electrical contact type Model: P650 series Differential pressure gauge with electrical contact type Model: P650 series Service intended The P650 series are designed to measure a differential pressure from 25 kpa to 2.0 MPa at static pressure up

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

1.2.3 Returning Instrument for Repair.

1.2.3 Returning Instrument for Repair. 2 Contents Installation....Page 5 Electrical and I/O...Page 8 Operating Principle...Page 11 Specifications.......Page 12 Operation.Page 14 Menu Screens......Page 15 Installation Tips and Troubleshooting.

More information

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc. All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed as warranties

More information

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6 C) RoHS No vibration or heat discharge New Energy saving in air flow

More information

Faster Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber Faster Temperature (& Humidity) Chamber SML2SMU2 SMS2SMG2 CAT.No.E04129-V1209 Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800

More information

Customized Industrial Products

Customized Industrial Products Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based

More information

Mountable in a 19-inch rack

Mountable in a 19-inch rack Peltier-Type Chiller/Thermo-con HECR Series Air-cooled Rack Mount Type (UL Standards) RoHS HRS Good space utilization Mountable in a 19-inch rack Saves space by mounting multiple equipment together in

More information

CHILLER. Modelli CWS BASIC CWS AQUACONTROL INSTALLATION MANUAL USAGE AND SCHEMATICS

CHILLER. Modelli CWS BASIC CWS AQUACONTROL INSTALLATION MANUAL USAGE AND SCHEMATICS CHILLER CWS AQUACONTROL Modelli CWS BASIC 121 161 201 251 301 INSTALLATION MANUAL USAGE AND SCHEMATICS A041252 16/10/2012 COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV =ISO 9001/2000 9001/2008 = ISO VECO

More information

Refrigerated Air Dryer Large Size Series

Refrigerated Air Dryer Large Size Series Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)

More information

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water

More information

DMFPM-2R MULTIFUNCTIONAL

DMFPM-2R MULTIFUNCTIONAL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Valve timing. Atmospheric air

Valve timing. Atmospheric air 31.5-mm wide vacuum unit is designed to optimize the control of large vacuum flows. Vacuum generator and External vacuum controller are available for various needs. Three different types of vacuum generator

More information

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features Discrete type for different piping conditions S/SU/S/SC Series Nozzle diameter: ø., ø., ø., ø., ø., ø. Different performance and shape are available to match different conditions. Features M M M This ejector

More information

Operation Manual Installation Operation

Operation Manual Installation Operation -G 1 st edition: Jul. 2009 8 th edition: Oct. 2010 Operation Manual Installation Operation Air-Cooled refrigerated type HRS012-A -10- HRS018-A -10- HRS012-A -20- HRS018-A -20- HRS024-A -20- Original Instructions

More information

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Series Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using

More information

Air Saver Unit. The power saving and CO 2 reduction products

Air Saver Unit. The power saving and CO 2 reduction products Air Saver Unit The power saving and CO 2 reduction products An easy solution to your environmental protection efforts! The air saving unit contributes to power savings and CO2 reduction. 50% LESS 2 OIL

More information

Added cooling capacity of 140 W. (air-cooled).

Added cooling capacity of 140 W. (air-cooled). Peltier-Type Chiller/Thermo-con Series Air-cooled Water-cooled Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using

More information

Recirculating Coolers

Recirculating Coolers 09 Recirculating Coolers (chillers) General Recirculating Coolers Low Temp. Recirculating Coolers Advanced Low Temp. Recirculating Coolers High Temp. Recirculating Coolers Compact Recirculating Cooler

More information

EN Manual FINAL (Ambient) NEW 4/26/99 5:03 PM Page 1 AMBIENT

EN Manual FINAL (Ambient) NEW 4/26/99 5:03 PM Page 1 AMBIENT EN Manual FINL (mbient) NEW 4/26/99 5:03 PM Page 1 MIENT 1 INSTRUTIONS p.1 MODE D EMPLOI p.31 EDIENUNGSNLEITUNG p.61 ISTRUZIONI p.91 INSTRUIONES p.121 GERUIKSNWIJZING p.151 RUKSNVISNING p.181 p.201 EN

More information

Can precisely control the temperature of a heat source or process fluid.

Can precisely control the temperature of a heat source or process fluid. Peltier-Type Chiller/Thermo-con Series Water-cooled HRS9 HRS Can precisely control the temperature of a heat source or process fluid. Water-cooled Added cooling capacity of 14 W and 32 W (watercooled),

More information

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor. Ultraviolet power monitor/illumination monitor Monitoring output state of UV (ultraviolet light)/illumination light source Features Optical Fiber Type Can be used as ultraviolet power monitor/illumination

More information

Azbil introduction 2015

Azbil introduction 2015 Azbil introduction 2015 Overview Azbil introduction & company profile Product divisions Product overview Magnetic flow meter (MTG) Magnetic flow meter (MGG) Thermal mass flow meters Pressure transmitter

More information

TotalPac 3 Firecyle III Deluge Remote controlled system

TotalPac 3 Firecyle III Deluge Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical

More information

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS) MAXIFLO TM Overview MaxiFlo TM KM Series Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter offering 2.0% full scale accuracy. It s based on simple and easy-to-understand

More information

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE Item 1) TWO THERMAL OIL HEATERS OF 1200 kw EACH 1.1) THERMAL OIL HEATER BODY Brand PIROBLOC Model GFT-060/40/H2 Power 1200 kw Delta Temperature 40 ºC Execution Horizontal Designed and built According AD-2000

More information

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual

More information

Air Saver Unit. The power saving and CO 2 reduction products

Air Saver Unit. The power saving and CO 2 reduction products Air Saver Unit The power saving and CO 2 reduction products An easy solution to your environmental protection efforts! The air saving unit contributes to power savings and CO2 reduction. 50% LESS 2 OIL

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract FEATURE ARTICLE Technical Reports The PLCA-800 Series Inline Particle Sensor for Chemical Solutions Yoshihito Yuhara Front end process Sensor module Wafer preparation process Film formation Photo lithography

More information

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g 1 Vacuum Module: Ejector System/Vacuum Pump System For electronic components and precision components up to 100 g Modular design Customized application function through selection of module components.

More information

Dome Fiber Optic Closure SC-221

Dome Fiber Optic Closure SC-221 Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and

More information

Security GSM Alarm System

Security GSM Alarm System Security GSM Alarm System USER MANUAL 4 wired and 6 wireless defense zones; Can preset and store 6 voice phones and 3 message phones; Remote two-way intercom; Telephone (mobile phone) remote control programming;

More information

Air Saver Unit. The power saving and CO 2 reduction products

Air Saver Unit. The power saving and CO 2 reduction products Air Saver Unit The power saving and CO 2 reduction products An easy solution to your environmental protection efforts! The air saving unit contributes to power savings and CO2 reduction. 50% LESS When

More information

BAMOSOFT Control. Water hardness monitor INSTRUCTIONS MANUAL DUR. BAMOSOFT Control. Water hardness monitor / M1 01 C

BAMOSOFT Control. Water hardness monitor INSTRUCTIONS MANUAL DUR. BAMOSOFT Control. Water hardness monitor / M1 01 C BAMOSOFT Control Water hardness monitor INSTRUCTIONS MANUAL Water hardness monitor BAMOSOFT Control 19-01-2011 376 M1 01 C DUR 376-01/1 Table of contents Page 1. Principle...3 2. Characteristics...4 3.

More information

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T)

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T) FOCAS-000 15ppm Bilge Alarm Product Specifications 01-06 Rev.1.03 (T) Alteration / correction hysteretic Date Revision The reason for revision / correction Approved Name 1 01-01-18 Rev.1.01 Internal Arrangement

More information

Remote Chexit Module (RCM) System. General Information

Remote Chexit Module (RCM) System. General Information *911032-00* 911032-00 Wiring and Configuration Remote Chexit Module (RCM) System Installation Instructions General Information The Von Duprin RCM is designed for controlled egress applications. It meets

More information

DC200 Digital Dispenser Operating Manual

DC200 Digital Dispenser Operating Manual DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine

More information

Ionisation single-tube smoke detector for duct mounting

Ionisation single-tube smoke detector for duct mounting Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models.

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

DE5300 Delayed Egress System. General Information

DE5300 Delayed Egress System. General Information *911031-00* 911031-00 Wiring and Configuration DE5300 Delayed Egress System Installation Instructions General Information The Von Duprin DE5300 is designed for controlled egress applications when used

More information

Radiator valve inserts

Radiator valve inserts Radiator valve inserts Valve insert cartridge The heart of the Oventrop radiator valve is the insert. All the working functions of the valve have been incorporated into a removable cartridge. This cartridge

More information

FCHM Hydromatic Pump Control Module

FCHM Hydromatic Pump Control Module FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to

More information

Universal fuel unit for oil burners

Universal fuel unit for oil burners Universal fuel unit for oil burners Type U www.deltapumps.com European patent Certified Quality System rinted in Italy - DE115/0404 Universal Fuel Unit for oil burners Type U The DETA Universal Fuel Unit

More information

DIRTCAL - DIRTMAG dirt separator

DIRTCAL - DIRTMAG dirt separator 864.07 www.caleffi.com DIRTCAL - DIRTMAG dirt separator Copyright 206 Caleffi 5462-546 -5465-5465M - NA5465 - NA5465M Series Installation, commissioning and servicing instructions Function In heating and

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching

More information

TEMPERATURE CONTROLLERS

TEMPERATURE CONTROLLERS Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

MC5-G1,G3 SPARE PARTS. Temperature Controller : TEMP. CONTROLLER CODE NO. PART NAME MACHINE MODEL PRICE (THB)

MC5-G1,G3 SPARE PARTS. Temperature Controller : TEMP. CONTROLLER CODE NO. PART NAME MACHINE MODEL PRICE (THB) SPARE PARTS Temperature Controller : TEMP. CONTROLLER 117749 TEMPERATURE CONTROLLER MR16-AN-04 (MC5-G1) MC5-G1 9,000 TEMP. CONTROLLER 118273 TEMPERATURE CONTROLLER MR16-CT-04 (MC5-G3) MC5-G3 20,000 FLOAT

More information

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English EH99862001-2 AIR CONDITIONER (SPLIT TYPE) Installation manual Branch kit 1:3 Model name: RBC-TRP100E Installation manual Air conditioner (Split type) 1 English Please read this Installation Manual carefully

More information

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly.

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly. Peltier-type Chiller Thermo-con/Rack Mount Type Air-cooled Water-cooled The water-cooled type has been added. (8 W, 1.2 kw) Reduces the amount of exhaust heat by 9% Suppresses rises in the ambient temperature

More information

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION STEAM TRAP CHECKING Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION Steam Traps Review - Mechanical Traps Float Inverted

More information

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52 Error Codes: Outdoor Units Error Codes: Outdoor Units Part. What Is in This Chapter? Introduction Overview In the first stage of the troubleshooting sequence, it is important to correctly interpret the

More information

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,

More information

Dynaflex Hot melt hoses

Dynaflex Hot melt hoses ITW Dynatec GmbH Industriestraße 28 D- 40822 Mettmann phone 0049 (0)2104 915 0 fax 0049 (0)2104 915 111 Dynaflex Hot melt hoses IMPORTANT! - READ ALL INSTRUCTIONS BEFORE OPERATING THIS EQUIPMENT It is

More information

MST RESPIRATORY PROTECTOR

MST RESPIRATORY PROTECTOR MST RESPIRATORY PROTECTOR PART NUMBERS AND SCHEMATICS GUIDE Company Profile Since 1944, Marco has developed a strong tradition of providing innovative and reliable products and services to the surface

More information

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division 966A AIR IONIZER Operation Manual Precautions...1 Safety precautions...1 Other precautions...1 Outline...2 Structure and kinds of the ionizer...2 Specifications...2 Characteristic...3 How to Install 966A

More information

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique REF-LOCATOR 4686714 TRACE-LOCATOR 4686715 Instruction Manual Electronic Leak Detector Bedienungsanleitung Elektronisches Lecksuchgerät Mode d emploi Détecteur de fuites électronique Istruzioni per l uso

More information

% by up ctoond re-heater and

% by up ctoond re-heater and Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA

More information

KELCO F29 PROGRAMMABLE FLOW SWITCH

KELCO F29 PROGRAMMABLE FLOW SWITCH KELCO F29 PROGRAMMABLE FLOW SWITCH INSTALLATION INSTRUCTIONS Version 130416 KELCO Engineering Pty Ltd Sydney Australia www.kelco.com.au VERY IMPORTANT This Kelco controller has been fully tested and calibrated.

More information

FLT93 Installation, Operation and Troubleshooting Guide

FLT93 Installation, Operation and Troubleshooting Guide FLT93 Installation, Operation and Troubleshooting Guide Pre-Installation A. To get the best results from the instrument, the instrument should be mounted 20 pipe diameters downstream from any valve, pipe

More information

SERVICE REQUIREMENTS

SERVICE REQUIREMENTS SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL270 Water Treatment System. Failure to follow the instructions in this manual could result in

More information

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator Series 282 Suitable for semiconductor industry such as IC chip loader or

More information

Instructions. Duct Mount Accessory Q Rev: 11/

Instructions. Duct Mount Accessory Q Rev: 11/ Instructions Duct Mount Accessory Q5016 Rev: 11/16 95-8752 Table of Contents DESCRIPTION...1 FEATURES...1 OPERATION...1 SPECIFICATIONS.... 2 INSTALLATION... 2 Detector Location...2 Tools for Assembly...4

More information

Hollow Fiber Membrane Filter Type Air Drier Unit Type

Hollow Fiber Membrane Filter Type Air Drier Unit Type http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Drier Unit Type Dry Unit 202 No electric power supply is required. Air Filter, Mist

More information

Model DM8 Vibration Type Density Meter

Model DM8 Vibration Type Density Meter User s Manual Model DM8 Vibration Type Density Meter R 3rd Edition Blank Page INTRODUCTION This manual describes the specifications, installation, operation, maintenance, and troubleshooting

More information