Lead Based Coatings Flowchart

Size: px
Start display at page:

Download "Lead Based Coatings Flowchart"

Transcription

1 Any Detectable Levels of Lead / Stop No Testing or Compliance Issues Lead Coatings NOT Target Housing or Child Occupied Facility Target Housing Child Occupied Family Georgia Certified Firm & Inspect by Georgia Certified Firm & 40 CFR 745 Inspect / Test Coatings Stream (TCLP) Test GA EPD Cert. N LBC Y / Project / Project Firm Renovator Minimum Requirements Cert. Abate Firm Cert. Abate Crew EPD NTP Comply EPA & Solid TCLP Occupant Protection Plan (Project Design?) Cleaning Verification by GA Certified Renovato Clearance (Per EPD) by Cert. / Risk Assessor working w 1,CJ

2 EPA AHERA K-12 Schools Asbestos Anyone Can Presume Asbestos PACM LEA Designated Person K-12 School O&M Program Inspection by Use EIA Purple Book Disturb Suspect Materials Non-K-12 (WHO?) Pre-Renovation & Stays Non-Friable Design by Project Designer Management Plan by Management Planner Inspect by Class I-IV Work Cat I Non-Friable Cat II Non-Friable Becomes Friable Comply GA Licensed Crew Implement Management Plan ND 1% ACM > 1% Georgia EPD > 10 sq ft > 10 lin ft RACM GA EPD Completion 3 rd Party Clearance PCM/TEM Air Monitoring Not Required But Should Be Considered Y LBC N Point Count if Friable PEL/EL/NEA Awareness Training Completion EPA NESHAP < 10 sq ft < 10 lin ft Licensed Asbestos 10 Day GA EPD Release Criteria (Clearance) -Visual -PCM -TEM Pay Fee to EPD Yes 10 day to GA EPD Project Completion to EPD NESHAP Trained Supervisor Y N Completion 1,CJ

3 EPA AHERA K-12 Schools Asbestos Anyone Can Presume Asbestos (PACM) LEA Designated Person K-12 School O&M Program Inspection by Use EIA Purple Book Disturb Suspect Materials Non-K-12 (WHO?) Pre-Renovation & Stays Non- Friable Design by Project Designer Management Plan by Management Planner Inspect by Class I-IV Work Cat I Non-Friable Cat II Non-Friable Becomes Friable Comply GA Licensed Crew Implement Management Plan ND 1% ACM > 1% Georgia EPD > 10 sq ft > 10 lin ft RACM GA EPD Completion 3 rd Party Clearance PCM/TEM Air Monitoring Not Required But Should Be Considered Point Count if Friable PEL/EL/NEA Awareness Training Completion EPA NESHAP < 10 sq ft < 10 lin ft Licensed Asbestos 10 Day GA EPD Release Criteria (Clearance) -Visual -PCM -TEM Pay Fee to EPD Yes 10 day to GA EPD Project Completion to EPD NESHAP Trained Supervisor Y N Completion PACM Presumed Asbestos Containing Material ACM Asbestos Containing Material RACM Regulated Asbestos Containing Material PCM Phase Contrast Microscopy 1,CJ TEM Transmission Electron Microscopy AHERA Asbestos Hazard Emergency Response Act NESHAP New Emissions Standards for Hazardous Air Pollutants

4 Any Detectable Levels of Lead / Stop No Testing or Compliance Issues Lead Coatings NOT Target Housing or Child Occupied Facility Target Housing Child Occupied Family Georgia Certified Firm & Inspect by Georgia Certified Firm & 40 CFR 745 Inspect / Test Coatings Stream (TCLP) Test GA EPD Cert. N LBC Y / / Firm Renovator Minimum Requirements Cert. Abate Firm Cert. Abate Crew EPD NTP Comply EPA & Solid TCLP Occupant Protection Plan (Project Design?) Cleaning Verification by GA Certified Renovator Completion Clearance (Per EPD) by Cert. / Risk Assessor working w Completion Renovation, Repair, Paint LBC Lead Based Paint TCLP Toxicity Characteristic Leaching Procedure 1,CJ

5 EPA AHERA K-12 Schools Asbestos Anyone Can Presume Asbestos (PACM) LEA Designated Person K-12 School O&M Program Inspection by Use EIA Purple Book Disturb Suspect Materials Non-K-12 (WHO?) Pre-Renovation & Stays Non- Friable Design by Project Designer Management Plan by Management Planner Inspect by Class I-IV Work Cat I Non-Friable Cat II Non-Friable Becomes Friable Comply GA Licensed Crew Implement Management Plan ND 1% ACM > 1% Georgia EPD > 10 sq ft > 10 lin ft RACM GA EPD Completion 3 rd Party Clearance PCM/TEM Air Monitoring Not Required But Should Be Considered Point Count if Friable PEL/EL/NEA Awareness Training EPA NESHAP < 10 sq ft < 10 lin ft Licensed Asbestos 10 Day GA EPD Release Criteria (Clearance) -Visual -PCM -TEM Pay Fee to EPD Yes 10 day to GA EPD Project Completion to EPD NESHAP Trained Supervisor Y N PACM Presumed Asbestos Containing Material ACM Asbestos Containing Material RACM Regulated Asbestos Containing Material PCM Phase Contrast Microscopy 1,CJ TEM Transmission Electron Microscopy AHERA Asbestos Hazard Emergency Response Act NESHAP New Emissions Standards for Hazardous Air Pollutants

6 Any Detectable Levels of Lead / Stop No Testing or Compliance Issues Lead Coatings NOT Target Housing or Child Occupied Facility Target Housing Child Occupied Family Georgia Certified Firm & Inspect by Georgia Certified Firm & 40 CFR 745 Inspect / Test Coatings Stream (TCLP) Test GA EPD Cert. N LBC Y / Project / Project Firm Renovator Minimum Requirements Cert. Abate Firm Cert. Abate Crew EPD NTP Comply EPA & Solid TCLP Occupant Protection Plan (Project Design?) Cleaning Verification by GA Certified Renovator Clearance (Per EPD) by Cert. / Risk Assessor working w Renovation, Repair, Paint LBC Lead Based Paint TCLP Toxicity Characteristic Leaching Procedure 1,CJ

Three Year Asbestos Re-Inspection Report. Macomb Montessori Academy East Nine Mile Road Warren, Michigan 47089

Three Year Asbestos Re-Inspection Report. Macomb Montessori Academy East Nine Mile Road Warren, Michigan 47089 Three Year Re-Inspection Report For 14057 East Nine Mile Road Warren, Michigan 47089 Prepared by: Northern Analytical Services, LLC. 14870 225 th Avenue Big Rapids, Michigan 49307 Dated: Project 160268

More information

ASBESTOS ROOF INSPECTION REPORT

ASBESTOS ROOF INSPECTION REPORT ASBESTOS ROOF INSPECTION REPORT OF MARSHALL COURTS ROOF 3300 A&B, 3302 A&B, 3400 A & B, 3402 A & B MARSHALL AVE 800 A & B 35 TH STREET AND 801 A&B 33 RD STREET NEWPORT NEWS, VIRGINIA 23606 MCS JOB #13-031S

More information

EPA/ODEQ DEMOLITION BY FIRE REQUIREMENTS

EPA/ODEQ DEMOLITION BY FIRE REQUIREMENTS EPA/ODEQ DEMOLITION BY FIRE REQUIREMENTS The OKLAHOMA AIR POLLUTION CONTROL RULES, Oklahoma Administrative Code (OAC) 252:100-13, Open Burning, specifically, subpart 5, Open burning prohibited, states:

More information

ASBESTOS POLICY. 2. Authority. 3. Scope. 4. Definitions. 4. Responsibilities. 1. Purpose. Department supervisors

ASBESTOS POLICY. 2. Authority. 3. Scope. 4. Definitions. 4. Responsibilities. 1. Purpose. Department supervisors 1. Purpose ASBESTOS POLICY The purpose of the University of Denver Asbestos Policy is to establish the means to prevent personal asbestos exposures to DU and contractor workers by managing and controlling

More information

Procedure. Procedure

Procedure. Procedure Procedure 4.1524 Asbestos Procedure A. Scope... 1 B. Applicability... 2 C. Definitions... 2 D. Responsibilities... 3 E. Hazards... 4 F. General Rules... 4 G. Asbestos Inventory... 5 H. Asbestos Identification...

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

If the address on this form is different than the address of the building, submit a written explanation.

If the address on this form is different than the address of the building, submit a written explanation. ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

AHERA Asbestos Management Plan

AHERA Asbestos Management Plan Our Services: Asbestos Inspections Asbestos Abatement Design Asbestos Abatement Oversight AHERA Asbestos Management Plan 720 Fairview Drive Carlisle, Ohio 45005 Asbestos Management Planning Phase I Environmental

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

If the address on this form is different than the address of the building, submit a written explanation.

If the address on this form is different than the address of the building, submit a written explanation. ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Youth Connection - J. Addams Alter HS

Youth Connection - J. Addams Alter HS ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Asbestos 3-Year Re-inspection Report and Updated Management Plan. Edith Nourse Rogers School 43 Highland Street Lowell, Massachusetts, 01852

Asbestos 3-Year Re-inspection Report and Updated Management Plan. Edith Nourse Rogers School 43 Highland Street Lowell, Massachusetts, 01852 Asbestos 3-Year Report Edith Nourse Rogers School 43 Highland Street, 01852 Prepared by: Cardno ATC 600 West Cummings Park, Suite 5450 Woburn, Massachusetts 01801 September 24, 2014 Cardno ATC Project

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Explain in writing if the address of the building is different than the address on this form:

Explain in writing if the address of the building is different than the address on this form: ILLINOIS DEPARTMENT OF PUBLIC HEALTH AHERA THREE YEAR REINSPECTION ASBESTOS ABATEMENT PROGRAM SCHOOL INFORMATION FORM SECTION I NAME OF SCHOOL DISTRICT: SCHOOL ID NUMBER: ADDRESS OF SCHOOL: CITY: CHICAGO

More information

Turn-Key Environmental Consultants, Inc. 790 Barnhart Rd. 714 Monument Ave. Phone: Troy, OH Dayton, OH Fax:

Turn-Key Environmental Consultants, Inc. 790 Barnhart Rd. 714 Monument Ave. Phone: Troy, OH Dayton, OH Fax: Turn-Key Environmental Consultants, Inc. 790 Barnhart Rd. 714 Monument Ave. Phone: 937-335-8807 Troy, OH 45373 Dayton, OH 45402 Fax: 937-339-4882 March 24, 2016 Mr. Dennis Zimmer City of Dayton, Division

More information

Palmyra High School 07/16 Addition and Renovation Palmyra, Nebraska

Palmyra High School 07/16 Addition and Renovation Palmyra, Nebraska Palmyra High School 07/16 Addition and Renovation Palmyra, Nebraska 845-001-14 DOCUMENT 00 31 26 - EXISTING HAZARDOUS MATERIAL INFORMATION 1.1 EXISTING HAZARDOUS MATERIAL INFORMATION A. This Document with

More information

ASBESTOS AWARENESS New Employee Training March Environmental, Facilities Services Eddie Pena (HazMat & IAQ Coordinator)

ASBESTOS AWARENESS New Employee Training March Environmental, Facilities Services Eddie Pena (HazMat & IAQ Coordinator) ASBESTOS AWARENESS New Employee Training March 2014 Environmental, Facilities Services Eddie Pena (HazMat & IAQ Coordinator) Why Are You Here? You need to know - Where there is (or may be) asbestoscontaining

More information

900 S. Colorado Blvd. - 5,609 square ft building (new automobile sales showroom and offices) built in 2000/2001; and

900 S. Colorado Blvd. - 5,609 square ft building (new automobile sales showroom and offices) built in 2000/2001; and Sent Via erims November 13, 2013 Sonic Automotive, Inc. 4401 Colwick Road Charlotte, North Carolina 28211 Attention: Mr. Doug Siska Re: Asbestos Survey Murray BMW of Denver 900 S Colorado Blvd and 4320

More information

At least 10 calendar days prior to project start date Within the last 30 days of a project that will extend beyond 12 months

At least 10 calendar days prior to project start date Within the last 30 days of a project that will extend beyond 12 months New York State Department of Labor Division of Safety and Health (518) 485-9263 Filing an asbestos project notification Who must provide asbestos project notification If the asbestos removal project is:

More information

ARTICLE 14.A WOOD STOVES AND FIREPLACES. Standards for Solid Fuel Burning Appliances

ARTICLE 14.A WOOD STOVES AND FIREPLACES. Standards for Solid Fuel Burning Appliances ARTICLE 14.A WOOD STOVES AND FIREPLACES Sec. G-IV 14.A.1 Sec. G-IV 14.A.2 Sec. G-IV 14.A.3 Sec. G-IV 14.A.4 Sec. G-IV 14.A.5 Sec. G-IV 14.A.6 Sec. G-IV 14.A.7 Sec. G-IV 14.A.8 Sec. G-IV 14.A.9 Intent Applicability

More information

ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota. Prepared for:

ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota. Prepared for: ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota Prepared for: City of St. Paul Department of Planning and Economic Development 1100 City Hall Annex 25 West 4 th Street

More information

EXHIBIT C DUCTLESS HEAT PUMP SPECIFICATIONS

EXHIBIT C DUCTLESS HEAT PUMP SPECIFICATIONS Page 1 of 5 DUCTLESS HEAT PUMP SPECIFICATIONS 1. NEW EQUIPMENT REQUIREMENTS a. Materials Equipment shall be a split system Ductless Heat Pump (DHP) with an inverter-driven, variable speed compressor, a

More information

I. INTRODUCTION Codes, Rules, Laws, & Requirements

I. INTRODUCTION Codes, Rules, Laws, & Requirements I. INTRODUCTION 1.03 Codes, Rules, Laws, & Requirements A. Buildings and sites are to be designed in conformance to the applicable requirements of the following: 1. The Texas Engineering Practice Act and

More information

CITY OF HOLLY SPRINGS STORMWATER UTILITY FREQUENTLY ASKED QUESTIONS

CITY OF HOLLY SPRINGS STORMWATER UTILITY FREQUENTLY ASKED QUESTIONS CITY OF HOLLY SPRINGS STORMWATER UTILITY FREQUENTLY ASKED QUESTIONS GENERAL What is a Stormwater Utility and why is it needed in Holly Springs? A Stormwater Utility is an entity responsible for the daily

More information

Contractor Safety. Workplace Safety & Environmental Division

Contractor Safety. Workplace Safety & Environmental Division Contractor Safety Workplace Safety & Environmental Division Click to edit Master title style This information is designed for tradespersons and persons supervising tradespersons who are performing work

More information

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344 CERTIFICATE OF OCCUPANCY Commercial Requirements In order to occupy a commercial property or rent space in the City of East Point, it is required that tenants and owners of a commercial building obtain

More information

NAVSEA STANDARD ITEM NUMERICAL INDEX

NAVSEA STANDARD ITEM NUMERICAL INDEX NAVSEA STANDARD ITEM NUMERICAL INDEX FY-17(CH-2) ITEM NO. 009-01 General Criteria; 009-02 Environmental Compliance Reports for Material Usage at Naval Facilities; 009-03 Toxic and Hazardous Substances;

More information

Objectives. To review updated IBC and fire test requirements when designing for life safety.

Objectives. To review updated IBC and fire test requirements when designing for life safety. Objectives To review updated IBC and fire test requirements when designing for life safety. To understand the relationship of fire safety and human impact safety. To clarify the difference between fire

More information

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date: Supplement Title: 365 Users Supplement Issue: 8 Part Number: 3622684 Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date: This supplement contains information necessary to ensure the accuracy

More information

HOUSEHOLD HAZARDOUS AND SPECIAL WASTES

HOUSEHOLD HAZARDOUS AND SPECIAL WASTES HOUSEHOLD HAZARDOUS AND SPECIAL WASTES What is hazardous and special Waste? Why should I be concerned? What alternatives do I have? How do I dispose of these things correctly? Who pays for disposal? Solid

More information

Summary of the situation. A pollution policy game. You are also a firm. You are also a firm 2/29/2016. Practice Round Manager

Summary of the situation. A pollution policy game. You are also a firm. You are also a firm 2/29/2016. Practice Round Manager Summary of the situation A pollution policy game There are 10firms in an area. Historically, they have not been regulated and have been emitting pollution. The history of emissions is presented on your

More information

A pollution policy game. Summary of the situation. You are also a firm 2/29/2016

A pollution policy game. Summary of the situation. You are also a firm 2/29/2016 A pollution policy game 4 Summary of the situation There are 10firms in an area. Historically, they have not been regulated and have been emitting pollution. The history of emissions is presented on your

More information

Leade rs in health, safety & environmen tal consultanc y & training. Training Courses 2017 Euro Price List. Valid as at December 2016

Leade rs in health, safety & environmen tal consultanc y & training. Training Courses 2017 Euro Price List. Valid as at December 2016 Leade rs in health, safety & environmen tal consultanc y & training Training Courses 2017 Euro Price List Valid as at December 2016 Courses Accredited Training Classroom Course elearning Course Asbestos

More information

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1 Building Codes & Standards for Healthcare Building Codes and Standards AHJs Codes Defend in Place Walls Sprinklers Fire Alarm Important Dates for Healthcare Facilities 7/5/16 NFPA Life Safety Code 101

More information

SOUTH PLAINS PUBLIC HEALTH DISTRICT

SOUTH PLAINS PUBLIC HEALTH DISTRICT 1 SOUTH PLAINS PUBLIC HEALTH DISTRICT ENVIRONMENTAL HEALTH SERVICES Proudly Serving the Communities of Gaines, Yoakum, Terry, Dawson and Lynn Counties APPLICATION FOR NEW CONSTRUCTION OR MODIFICATION 1.

More information

+Sullivan County Dept. of Solid Waste & Recycling. A Users Guide to Recycling & Waste Disposal Programs in Sullivan County, New York

+Sullivan County Dept. of Solid Waste & Recycling. A Users Guide to Recycling & Waste Disposal Programs in Sullivan County, New York +Sullivan County Dept. of Solid Waste & Recycling A Users Guide to Recycling & Waste Disposal Programs in Sullivan County, New York - 2017 Practically every municipality in the country has its own unique

More information

Asbestos in the Community EHPA

Asbestos in the Community EHPA Asbestos in the Community EHPA Darren Watson Inspector WorkSafe Victoria 20 th June 2016 Contents What is asbestos Forms of asbestos containing material (ACM) Health hazard & risk to health Types of ACM

More information

COASTAL DEVELOPMENT PERMIT REQUIRING A PUBLIC HEARING

COASTAL DEVELOPMENT PERMIT REQUIRING A PUBLIC HEARING Santa Barbara County Coastal Development Permit-Hearing Application Page 1 COASTAL DEVELOPMENT PERMIT REQUIRING A PUBLIC HEARING A COASTAL DEVELOPMENT PERMIT REQUIRING A PUBLIC HEARING (CDH) necessary

More information

06-96 DEPARTMENT OF ENVIRONMENTAL PROTECTION CONTROL OF EMISSIONS FROM OUTDOOR WOOD BOILERS

06-96 DEPARTMENT OF ENVIRONMENTAL PROTECTION CONTROL OF EMISSIONS FROM OUTDOOR WOOD BOILERS Chapter 150: CONTROL OF EMISSIONS FROM OUTDOOR WOOD BOILERS SUMMARY: This regulation establishes particulate emission standards, siting criteria and labeling requirements for outdoor wood boilers. 1. Applicability.

More information

Understand what asbestos is and how to avoid exposure

Understand what asbestos is and how to avoid exposure Understand what asbestos is and how to avoid exposure. PINCHIN & AFFILIATES A leader in engineering, environmental health & safety solutions Multi-disciplinary approach by highly qualified, experienced

More information

885 Lakeport Boulevard Phone: (707) Section 467 Lakeport, CA Fax: (707) LCAQMD #

885 Lakeport Boulevard Phone: (707) Section 467 Lakeport, CA Fax: (707) LCAQMD # LAKE COUNTY AIR QUALITY Asbestos Demolition/Renovation MANAGEMENT DISTRICT NOTIFICATION FORM 885 Lakeport Boulevard Phone: (707) 263-7000 Section 467 Lakeport, CA 95453 Fax: (707) 263-0421 LCAQMD # SITE

More information

ROGUE VALLEY SEWER SERVICES STORMWATER MANAGEMENT PROGRAM (SWMP)

ROGUE VALLEY SEWER SERVICES STORMWATER MANAGEMENT PROGRAM (SWMP) ROGUE VALLEY SEWER SERVICES STORMWATER MANAGEMENT PROGRAM (SWMP) 1.0 INTRODUCTION This Stormwater Management Program (SWMP) for Rogue Valley Sewer Services (RVS) has been developed to meet the Municipal

More information

I. FACILITY NYC DEPARTMENT OF ENVIRONMENTAL PROTECTION Asbestos Control Program 59-17 Junction Boulevard, 8th Floor, Flushing, NY 11373 ASBESTOS PROJECT NOTIFICATION (Form ACP7) This form must be submitted

More information

DULANEY HIGH SCHOOL FEASIBILITY STUDY

DULANEY HIGH SCHOOL FEASIBILITY STUDY DULANEY HIGH SCHOOL FEASIBILITY STUDY APPENDIX A: SITE PLAN Baltimore County Public Schools Site Plan-Appendix A Office of Engineering and Construction February 18, 2016 Dulaney High School Feasibility

More information

Property Health and Safety Compliance at Housing and Education Centres

Property Health and Safety Compliance at Housing and Education Centres Property Health and Safety Compliance at Housing and Education Centres Title: Property Health and Safety Reference number: Compliance at Housing and Education Centres Status Final Publication Internal

More information

2014 City of Revelstoke Woodstove Exchange Program

2014 City of Revelstoke Woodstove Exchange Program 2014 City of Revelstoke Woodstove Exchange Program GOAL: Our goal is to improve air quality by lowering smoke emissions. This program combines education and economic incentives to assist residents to operate

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory 154 Kamrabad, Atarar Depot Chittagong Chittagong Chittagong The Alliance for Worker Safety Page 1/7 Introduction to the Report The following report contains

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Bashtoli, Sinabah, Sofipur, Kaliakoir, Gazipur Gazipur Dhaka 08 Sep 2014 The Alliance for Worker Safety Page 1/10 Factory 08 Sep 2014 Introduction to the Report The

More information

CITY OF CYPRESS 5275 Orange Avenue Cypress, California (714) DESIGN REVIEW COMMITTEE PERMIT PROCESS

CITY OF CYPRESS 5275 Orange Avenue Cypress, California (714) DESIGN REVIEW COMMITTEE PERMIT PROCESS CITY OF CYPRESS 5275 Orange Avenue Cypress, California 90630 (714) 229-6720 DESIGN REVIEW COMMITTEE PERMIT PROCESS 1. Discuss project with Planning staff to determine zoning regulations, any unusual characteristics

More information

Locations must be selected where the detector is not to be disturbed during the measurement period.

Locations must be selected where the detector is not to be disturbed during the measurement period. INSPECT DES MOINES, LLC RESIDENTIAL RADON AGREEMENT (Please Read Carefully) This radon agreement is supplemental to the pre-inspection agreement. Both agreements must be signed in order for a home inspection

More information

NARRATIVE REPORT. Underlayment Paper for Linoleum. The Asbestos Bulk Sample Results Table includes asbestos sampling data.

NARRATIVE REPORT. Underlayment Paper for Linoleum. The Asbestos Bulk Sample Results Table includes asbestos sampling data. NARRATIVE REPORT 1.0 BUILDING INFORMATION Engineering and Technology was originally constructed in 1913; although specific information is unavailable, several renovations are evident. Engineering and Technology

More information

Vermiculite Containing Materials

Vermiculite Containing Materials Vermiculite Containing Materials Analytical Challenges Copyright EMSL 2013 1 New York Guidance 04/11 Copyright 2013 2 New York Guidance 06/22/12 Copyright 2013 3 1 New York Guidance 07/09/13 Copyright

More information

LICENSES FOR UTILITY CROSSINGS OF PUBLIC LANDS AND WATERS ACCORDING TO MINNESOTA RULES CHAPTER [Rules Effective July 1, 2004]

LICENSES FOR UTILITY CROSSINGS OF PUBLIC LANDS AND WATERS ACCORDING TO MINNESOTA RULES CHAPTER [Rules Effective July 1, 2004] LICENSES FOR UTILITY CROSSINGS OF PUBLIC LANDS AND WATERS ACCORDING TO MINNESOTA RULES CHAPTER 6135 [Rules Effective July 1, 2004] Minnesota Department of Natural Resources Division of Lands and Minerals

More information

Site Address: Bldg./Suite #: Departments Phone Date Approval Signature A) Planning COMMENTS:

Site Address: Bldg./Suite #: Departments Phone Date Approval Signature A) Planning COMMENTS: Development Services Department 135 N. 'D' Street P) 951-943-5003 F) 951-943-6504 www.cityofperis.org STEP 1: Prepare for your permit Before you can start this application/permit you will need the following:

More information

School EMERGENCY PLAN

School EMERGENCY PLAN School EMERGENCY PLAN The following outline covers the main criteria for emergency guidelines for this facility and its operations. The outline will be under review with local officials and details are

More information

2. What is required if I want to put some patio/bistro tables and chairs on the sidewalk and remove them at the end of each day?

2. What is required if I want to put some patio/bistro tables and chairs on the sidewalk and remove them at the end of each day? DOWNTOWN SEASONAL PATIOS The establishment and use of seasonal patios in downtown Cranbrook will be regulated by City of Cranbrook Downtown Seasonal Patio Bylaw No. 3860, 2016. This bylaw provides regulations

More information

ANNUAL / Renewable TOTAL: $

ANNUAL / Renewable TOTAL: $ Storey County Community Development P O Box 526 ~ Virginia City NV 89440 ~ (775) 847-0966 Business License Business Name: Acct Number: Phone: ( ) - License Dates: to Annual License Type: Annual License

More information

Lead in Oakland Soils

Lead in Oakland Soils Superfund Lead in Oakland Soils South Prescott Fishbone Project Oakland, CA US Environmental Protection Agency Region 9 San Francisco, CA August 30, 2012 LEAD IN OAKLAND SOILS Introduction Best practices

More information

Property Inspected: 623 Pine St, Macon, GA 31201

Property Inspected: 623 Pine St, Macon, GA 31201 February 5, 2016 Test Number: 8401-12 Property Inspected: 6 Pine St, Licensed Radalink Radon Inspector: ACME Home Inspections John Harwell 994 Magnolia St Phone: Fax: 770 555 1944 770 555 2105 Calibrated:

More information

Retrofitting Commercial Shopping Centers

Retrofitting Commercial Shopping Centers Retrofitting Commercial Shopping Centers Making an impact with LID Overview Commercial Development LID Retrofit Issues Tips and techniques Costs and O&M issues Commercial Development LID Retrofit Issues

More information

Safe Removal of Asbestos. Work Safe Week 2013

Safe Removal of Asbestos. Work Safe Week 2013 Safe Removal of Asbestos Work Safe Week 2013 Work Safe Week 2013 For the respect of others please ensure your mobile phone is switched off or on silent. In the event of an emergency a Convention Centre

More information

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS 1) Purpose: In an effort to provide for consistency in administering the Existing Building Code and Property Maintenance Code for existing buildings as they pertain to Certificates of Use and Occupancy,

More information

City of Manassas Park Proposed Stormwater Management Funding

City of Manassas Park Proposed Stormwater Management Funding City of Manassas Park Proposed Stormwater Management Funding October 5, 2010 State and Federal Storm Water Mandates The State mandates implementation of ordinance, programs, and practices to meet storm

More information

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

Consumer Fireworks Retail Sales (CFRS) Facility Requirements. Consumer Fireworks Retail Sales (CFRS) Facility Requirements. Site Plan. The site plan for tents shall show the location of the tent on the site and indicate the minimum separation distances required by

More information

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS The to the 2013 Energy Code for prescriptive compliance for HERS required measures for residential alterations is a guide for those who

More information

Intentionally Left Blank

Intentionally Left Blank Intentionally Left Blank CITY OF LOS ANGELES LOW IMPACT DVELOPMENT BEST MANAGEMENT PRACTICES HANDBOOK LOW IMPACT DEVELOPMENT (LID) CHECKLIST SMALL SCALE RESIDENTIAL (4 UNITS OR LESS) WPD Project Plan Checker:

More information

NESHAP 6W Notification of Compliance Status

NESHAP 6W Notification of Compliance Status NESHAP 6W Notification of Compliance Status NOTIFICATION OF COMPLIANCE STATUS FOR PLATING AND POLISHING SOURCES 1 (as amended on May 31, 2018) This Notification of Compliance Status is to meet the requirements

More information

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by 2 Sponsored by: Boiler MACT Deadline Is Here, Are You In Compliance? Webinar Presentation January 21, 2016 PH Haroz President Conversion

More information

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. IF YOU RECEIVED A NOTICE BY MAIL AND YOU DO NOT CURRENTLY HAVE A FIRE ALARM INSTALLED IN YOUR BUILDING, YOU MAY DISREGARD THE NOTICE. Dear Building

More information

Mobile Food Vendors Business License Requirement Checklist

Mobile Food Vendors Business License Requirement Checklist Mobile Food Vendors Business License Requirement Checklist In accordance with the Vineyard Municipal Code Part 9-460, mobile food business owners must complete and submit the following to Vineyard before

More information

BE IT ORDAINED BY THE COUNCIL OF THE CITY OF NORWICH

BE IT ORDAINED BY THE COUNCIL OF THE CITY OF NORWICH ORDINANCE 1769 ADOPTED 7/2/2018 PUBLISHED 7/4/2018 AN ORDINANCE AMENDING THE ZONING REGULATIONS OF THE CITY OF NORWICH, CONTAINED IN THE COMPREHENSIVE PLAN BY ADDING REGULATIONS FOR A VILLAGE DISTRICT

More information

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration.

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration. February 5, 2016 Test Number: 8401-12 Property Inspected: 623 Pine St, Macon, GA 31201 Licensed Radalink Radon Inspector: Test performed for: ACME Home Inspections William Jacobs John Harwell 943 Spring

More information

City of Camdenton. 437 W US Hwy 54 Camdenton, MO Application for a City Business License

City of Camdenton. 437 W US Hwy 54 Camdenton, MO Application for a City Business License City of Camdenton 437 W US Hwy 54 Camdenton, MO 65020 Application for a City Business License License expires May 31 of each year. Beginning July 1, a penalty will be added for each month the license is

More information

Massachusetts Work Practices for Lead-safe Renovation

Massachusetts Work Practices for Lead-safe Renovation Workers performing work that falls under the Lead-safe Renovation Regulations are required to be trained. If the workers have not received training as a Deleader-supervisor, Deleading worker, or Leadsafe

More information

FIRE SAFETY SEMINAR 2009 WORKSHOP DISCUSSION

FIRE SAFETY SEMINAR 2009 WORKSHOP DISCUSSION FIRE SAFETY SEMINAR 2009 WORKSHOP DISCUSSION BREAKOUT GROUPS DISCUSSIONS Approval of plans Building owner is making renovations to few units and asks FSM for advice? Please enlighten owner. FSM should

More information

Fire Safety in Schools Post-Grenfell Fire

Fire Safety in Schools Post-Grenfell Fire Fire Safety in Schools Post-Grenfell Fire Joint Guidance to School Leaders from the National Education Union (NEU), National Association of Headteachers (NAHT) and the Association of School and College

More information

Sec. 2. Subsection A of Section of the Los Angeles Municipal Code is hereby amended by adding Item 18 thereto, Said item to read:

Sec. 2. Subsection A of Section of the Los Angeles Municipal Code is hereby amended by adding Item 18 thereto, Said item to read: ~--------------- t'..; ORDINANCE NO. 168176 An ordinance adding Division 10 to Article 7 of Chapter 5 of the Los Angeles Municipal Code to regulate asbestos abatement. THE PEOPLE OF THE CITY OF LOS ANGELES

More information

Leaders in health, safety & environmental consultancy & training

Leaders in health, safety & environmental consultancy & training Leaders in health, safety & environmental consultancy & training Training Courses 2016 Courses Asbestos Legionella Accredited Training Classroom Course elearning Course Asbestos Awareness (Category A)

More information

Asbestos Awareness at the University of Toronto

Asbestos Awareness at the University of Toronto Asbestos Awareness at the University of Toronto What is Asbestos? Asbestos is a general term given to a group of naturally occurring mineral silicates that are made up of long thin fibres. These fibrous

More information

2005 LRDP Amendment 3

2005 LRDP Amendment 3 2005 LRDP Amendment 3 LONG RANGE DEVELOPMENT PLAN 2005 LRDP AMENDMENT 3 ii 2005 LRDP AMENDM ENT 3 LAND USE 2005 LRDP Amendment 3 Campus Infrastructure Overlay Land Use Designation September 2013 iii LONG

More information

Occupant Load Calculations For Assembly Occupancies and Licensed Beverage Establishments

Occupant Load Calculations For Assembly Occupancies and Licensed Beverage Establishments FIRE AND RESCUE SERVICES FIRE PREVENTION DIVISION March 15, 2017 Bulletin 2017-002-FI Occupant Load Calculations For Assembly Occupancies and Licensed Beverage Establishments This bulletin provides guidance

More information

Plan Submittal Checklist

Plan Submittal Checklist City of Aurora Public Works Department HIGH-PILED COMBUSTIBLE STORAGE Plan Submittal Checklist Building Division 15151 E. Alameda Parkway, Ste 2400 Aurora, CO 80012 303-739-7420 Fax: 303-739-7551 Project

More information

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities 1 Colby Henson Fire Safety Supervisor 665 Mainstream Drive 2nd floor 615-806-4798 Colby.Henson@tn.gov

More information

Part 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures

Part 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures Part 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures Overview Safe Work Practice Requirements - RRP Common Misconceptions Enforcement & Outreach Public & Commercial Buildings

More information

N.J.A.C. 5: A. NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law

N.J.A.C. 5: A. NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law N.J.A.C. 5:23-2.17A NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law *** This file includes all Regulations adopted and published through the *** *** New

More information

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE 1. BUILDING FEES: 1 AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE ESTABLISHMENT OF FEES PURSUANT TO N.J.A.C.

More information

APPE NDIX E TY PE 1 ASBE STOS WOR K PROCEDURES

APPE NDIX E TY PE 1 ASBE STOS WOR K PROCEDURES APPE NDIX E TY PE 1 ASBE STOS WOR K PROCEDURES TY PE 1 ASBE STOS WOR K PROCEDURES These procedures are to be followed by workers and contractors performing the following work at KPDSB buildings. Installing

More information

REQUIREMENTS & GUIDELINES

REQUIREMENTS & GUIDELINES SMALL CENTERS IN A RESIDENCE (6-12 Children) REQUIREMENTS & GUIDELINES Mecklenburg County Code Enforcement and the North Carolina Department of Health and Human Services Division of Child Development are

More information

Model Carbon Monoxide (CO) Alarm Response Policy

Model Carbon Monoxide (CO) Alarm Response Policy Published on MTAS (http://www.mtas.tennessee.edu) January 26, 2019 Model Carbon Monoxide (CO) Alarm Response Policy Summary: This model policy was created to provide procedures for personnel to follow

More information

Facilities Standards for the Public Buildings Service

Facilities Standards for the Public Buildings Service Facilities Standards for the Public Buildings Service March 2005 U.S. GENERAL SERVICES ADMINISTRATION OFFICE OF THE CHIEF ARCHITECT ON THE COVER Table of Contents United States Courthouse Seattle, Washington

More information

example of approved application

example of approved application APPLICANT INFORMATION 1. Primary Contact (project manager) Information Name Erik Josephson Municipality/Organization Name (applicant) Does the municipality/organization have any qualified Tree Tenders

More information

As we operate the hotel, we may want to do some renovation works to improve the service level and guest experience. This will involve application for

As we operate the hotel, we may want to do some renovation works to improve the service level and guest experience. This will involve application for As we operate the hotel, we may want to do some renovation works to improve the service level and guest experience. This will involve application for Addition & Alteration Permit to carry out those works.

More information

ST. LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE

ST. LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE ST. LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE RESOLUTION NO. 660-18 ST LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE RESOLUTION NO. #660-18 A RESOLUTION OF THE ST. LUCIE COUNTY FIRE DISTRICT, SPECIFICALLY

More information

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS CHAPTER 23.45 LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS 23.45.100 Local Amendments To The International Fire Code, 2000 Edition 23.45.102.1 Construction and Design Provisions

More information