Heat Recovery Ventilator
|
|
- Candice Stewart
- 5 years ago
- Views:
Transcription
1 REKUPETORI
2
3 Heat Recovery Ventilator
4 Heat recovery ventilator Larger air supply rate enhanced heat exchange efficiency enhanced energy saving property The heat recovery ventilator (HRV) can reclaim heat energy lost through ventilation and reduce the room temperature fluctuation caused by ventilation process. By utilizing the most advanced technology and technics, HRV has extremely good performance. The heat exchanged core is made of special paper processed with chemical treatment, which could realize better temperature and humidity control of the room environment. Temperature exchange efficiency is above 65% and enthalpy exchange efficiency between 50-65%. Model Names HRV-200 HRV-300 HRV-400 HRV-500 HRV-800 HRV-1000 Heat Moistureu Cold air 0 0 C 6 C Heat 14 C Moisture Warm air 20 C C (Returm air from room) (Supply air to room) HRV-1500 HRV-2000 Heat exchange plate (Exhaust air to outdoors) (Fresh air from outdoors) Low noise Sound proof material is used to guarantee quiet operation. Compact design, flexible installation and easy maintenance With a min. height of only 10-25/64in.(264mm) and 50lbs (23kg) weight, the unit provides best convenience and possibility for installation in limited spaces /64in.(264mm) 146
5 Multi-modes for different situations Heat exchange mode When air flow formed by the fans goes through the heat exchanged core in cross way, due to temperature difference between two channels of the core, thermal transmission happens naturally. In summer days, high temperature outdoor air gets cooled by indoor exhaust air; in winter, low temperature outdoor air gets heated by indoor exhaust air. So the energy contained in exhaust air can be reclaimed and energy efficiency gets improved. Heat exchange mode Element Bypass mode Damper Damper Bypass mode In mild climate areas or seasons, when temperature and humidity level difference between indoor and outdoor is small, the unit works as conventional ventilation fan. Both supply fan and exhaust fan works at the same speed (Hi/mid/low/auto). Element Air supply mode It is one kind of bypass mode with air supply fan speed higher than exhaust fan speed. It can be used in mild climate area where large amount fresh air is needed. Exhaust air mode It is also one kind of bypass mode with exhaust fan speed higher than air supply fan speed. It can be used in mild climate area where large amount exhaust air needs to be expelled. Auto mode The controller chooses heat exchange mode or bypass mode according to the temperature difference between outdoor and indoor temperature. Both the two fans work at low speed. Flexible control Interlocking control with other indoor units by controller is possible. Duct (Obtain locally) IDU IDU Centralized control CRF-30-CM 147
6 Specifications Model HRV-200 HRV-300 HRV-400 HRV-500 Power supply V-Ph-Hz 220V-1Ph-50Hz Cooling Heating Indoorfan motor Indoor fan Temp. efficiency % Enthalpy efficiency % Temp. efficiency % Enthalpy efficiency % Model YDK A1 YDK A2 YDK A2T YDK T Insulation class Safe class Input W Capacitor uf Speed r/min material Type B IP34 ABS Centrifugal fan Diameter mm Φ154 Φ194 Φ194 Φ203 Height mm Indoor static pressure and air flow Pa/m 3 /h 75/200 75/300 80/400 80/500 Indoor external static pressure (Hi) Pa Sound pressure level db(a) Indoor unit Connection wiring Controller Fresh air Dimension (L W H) mm Packing (L W H) mm Net/Gross weight kg 23/40 26/44 31/52 41/64 Power wiring mm Signal wiring mm Wired controller Fresh Air Diameter mm Φ144 Φ144 Φ144 Φ194 Air drop Pa Model HRV-800 HRV-1000 HRV-1500 HRV-2000 Power supply V-Ph-Hz 220V-1Ph-50Hz 380V-3Ph-50HZ Cooling Temp. efficiency % Enthalpy efficiency % Heating Temp. efficiency % Enthalpy efficiency % Model YDK B1T YDK A4T SYB-250I (0.45-4) SYB-250II (0.45-4) Insulation class B Indoorfan motor Safe class IP34 IPX4 Input W Capacitor uf Speed r/min material ABS metal Indoor fan Type Centrifugal fan Diameter mm Φ245 Φ245 Φ234 Φ254 Height mm Indoor static pressure and air flow Pa/m 3 /h 100/ / / /2000 Indoor external static pressure (Hi) Pa Sound pressure level db(a) Dimension (L W H) mm Indoor unit Packing (L W H) mm Net/Gross weight kg 62/88 79/ / /247 Connection Power wiring mm wiring Signal wiring mm Controller Wired controller Fresh air Fresh Air Diameter mm Φ242 Φ Air drop Pa Note: 1. For the units model of HRV-200~HRV-1000, there are 3-speed adjustable air-volume (Hi, Med, Low), but for the units model of HRV-1500 and HRV-2000, there are only 1-speed air-volume which cannot be adjust. 2. For the units model of HRV-200~HRV-1000, all the parameters in the manual is measured at the high speed air-volume. 148
7 AHI CARRIER SOUTH STERN EUROPE S.A.
Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More informationturn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES
turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners
More informationPart 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...
MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information
More informationVentilation unit Zehnder ComfoAir 200
Use The Zehnder ComfoAir 200 comfort ventilation unit was developed for use in residential settings with high ventilation demand. It combines maximum comfort, simple operation and high efficiency with
More informationMulti Inverter Air Conditioning Condensing Units - Summary
Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1
More informationResidential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators
Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify
More informationInspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV
Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators
More informationSubmittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18
Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More informationOverview and Specifications
Overview and Specifications ComfoAir 200 1 General Information Use The ComfoAir 200 ventilation unit was developed for residential and small commercial buildings. It combines maximum comfort, simple operation
More information42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n
Carrier Corporation identified six specific areas of concentration that directly impact how we, as a world manufacturer, balance our curtomer' needs for comfort with the environment's needs for responsible
More information[U] Serie MHB / MHA Manual de Ingeniería
[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance
More informationResidential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators
Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationfor a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More information1. Features Specification Dimensions Refrigeration cycle diagram Operation limits
GLORY (ECO) STAR SERIES 1. Features 60 2. Specification 61 61 3. Dimensions 67 67 4. Refrigeration cycle diagram 70 70 5. Operation limits 71 6. Wiring diagram 72 7. Troubleshooting 80 8. Electronic function
More informationUCV CONDENSING UNITS SPECIFICATIONS 1. Specifications
UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationMini Split Air Conditioners and Heat Pump
new improved design Mini Split Air Conditioners and Heat Pump TECHNOLOGY Environment concern is a priority all over the world. Environment concern is our responsibility and working philosophy. 140 105
More informationFloor-Standing Type(E Series)
Floor-Standing Type(E Series) Model: MFE-60CE, MFE-60AE Part 1. Product Features With a spiral shape, the computer-aided simulation designed air passage system can efficiently reduce noise. The Soft touch
More informationR410A50Hz Universal Outdoor Series Technical Manual
Outdoor Unit R410A 50Hz Universal Outdoor Series Technical Manual 2013 Version LCAC/2.0/201308 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Content PART 1.General Information... 1 1.Nomenclature...
More informationMystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)
Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay
More informationMiraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.
Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. High Efficiency Green Slim Line Ceiling Concealed Ducted Split Systems Cool Only Rev. August 2015 12K - 18K - 24K - 30K - 36K - 42K - 48K - 60K IAQ
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More informationHRV Enthalpy. Catalogue
HRV Enthalpy Catalogue BM896 Iss 02 - Enthalpy MVHR Contents HRV1.35 Q Plus - Enthalpy...3 HRV2 Q Plus - Enthalpy...5 HRV3 Q Plus - Enthalpy...7 HRV10.25 Q Plus - Enthalpy...9 Heat Water vapour Gases and
More informationHeat Recovery Ventilation
Service Manual Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM 350FAVE VAM 500FAVE VAM 650FAVE VAM 800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM
More information[U] Serie MOV. Manual de Ingeniería
[U] Serie MOV Uniidades Condensadoras (Fllujjo Verttiicall) 6..3,, 8 y 12..5 Ton Manual de Ingeniería - 112- Outdoor Units_MOV 1. Specifications.... 2. Dimension... 3. Service Space. 4. Piping Diagrams
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationThe latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS
The latest innovation in cool 7 YEAR WARRANTY ON COMPRESSORS 1 YEAR WARRANTY ON PARTS Engineered to be both aesthetically pleasing and energy-efficient, Katashi air conditioning units bring the latest
More informationENERGY RECOVERY VENTILATOR
ENERGY RECOVERY VENTILATOR ERV 60H Part no. 606 (TOP PORTS) Part no. 60 (SIDE PORTS) 5 to 05 CFM (0. in. w.g.) VB0073 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured
More information20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR
ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the
More informationPRODUCT RANGE: ROOFTOP PACKAGE
Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They
More informationHEAT RECOVERY VENTILATOR
HEAT RECOVERY VENTILATOR CONSTRUCTO 1.0 HRV Part no. 41502 (TOP PORTS) Part no. 41500 (SIDE PORTS) 39 to 98 CFM (0.4 in. w.g.) VB0069 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT!
More informationHorizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9
ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationFRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %
FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION
More informationMobile Type Air Conditioner
Mobile Type Air Conditioner 1. Features 2. Specification 3. Wiring diagram 4. Trouble shooting 5. Electronic function 36 1. Features 1.1The currently manufactured mobile air conditioners include the following
More informationROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION
ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION 2 AERECO Room-by-room demand controlled heat recovery ventilation REVOLUTION IN THE WORLD OF HEAT RECOVERY VENTILATION Through its new ventilation
More informationResolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h
Comfort air conditioning unit with highly efficient regenerative heat storage packages 62 26 01 - simplified illustration Automatically selects the most economical operating mode! 62 and 66 AIR OLUME FLOW:
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationTSEK VHR EC HEAT RECOVERY UNITS
TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.
More informationHigh static Pressure Duct Type Air-conditioner
High static Pressure Duct Type Air-conditioner Part 1. Product Features In case the ceiling is super-high. Blowing pressure of Indoor Unit can reach 196Pa. The air conditioner delivers cold wind to every
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationMidea Ducted and Cassette Split Systems. Maximum versatility, maximum value.
Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationDAIKIN Air Handling Unit Modular
DAIKIN Air Handling Unit Modular Compact ventilation unit with heat recovery Energy efficiency and air quality Daikin air handling units, with their plug-and-play design and inherent flexibility, can be
More informationCooling Fans ver ver.4
H Cooling Cooling H-1 Overview of Cooling... H-2 Overview Axial... H-13 Low-Power Consumption EMU Series H-18 Axial Low-Power Consumption EMU MU Series H-20 Large Size, Large Air MRS Series H-22 MRE Series
More informationSlim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump
0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient
More information250mm dia straight pipe length SP4 SP3. Air volume
MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material
More informationDuct air-handling units
Why Vento? Duct units Vento are constructed to help to implement comprehensive but simple air handling devices at the same time. Only Vento offers You 10 advantages: Variability and compactness of products
More informationVentilation Unit Zehnder ComfoAir 350
Use The ComfoAir 350 ventilation unit was developed for residential and small commercial buildings. It combines maximum comfort, simple operation and very high efficiency. The CA350 moves up to 218 cfm
More informationContents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...
Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5
More informationMRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)
NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1
More informationTHE EFFECT OF ENTHALPY RECOVERY VENTILATION ON THE RESIDENTIAL INDOOR CLIMATE
THE EFFECT OF ENTHALPY RECOVERY VENTILATION ON THE RESIDENTIAL INDOOR CLIMATE Bart Cremers Zehnder Group Nederland Lingenstraat 2 8028 PM Zwolle, The Netherlands bart.cremers@zehndergroup.com ABSTRACT
More informationService Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM
Service Manual Multi Split Type Heat Pump Air Conditioners Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM CONTENT 1. Product features 2. Specification 3. Dimensions 4. Refrigeration cycle
More informationSEQUENCE OF OPERATIONS
SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,
More informationHitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Set Free VRF Systems Mini 2-pipe S i d e fl o w2 - p i p e Modular 2 or 3-pipe Std - Efficiency Hi-Efficiency
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationWhole Home Heat Recovery Ventilation
Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay
More informationTechnical Guide. Split Air-Conditioners Equipment Residential COS Series
Technical Guide Split Air-Conditioners Equipment Residential COS Series TECHNICAL GUIDE SPLIT AIR-CONDITIONERS EQUIPMENT Thank you for choosing our products Note: Technical information contained in this
More informationCommercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF
2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT
More informationMulti Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by
Multi Split Systems Reverse Cycle, Inverter Air Conditioner Exclusively distributed by AUS 13 23 50 www.lennoxaus.com.au NZ 0800 653 330 www.lennoxnz.co.nz 1 As a global leader in comfort solutions, Lennox
More informationtechnical data Fan coil unit FWB small duct unit
technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------
More informationMRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation
NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent
More informationPremium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units
Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to
More informationDV-PP-L-125 DV-PP-L-150. Noise level [db] Capacity [m3/h]
Duct fans for round ventilation systems DV-PP-L The DV-PP-L duct fan is used to supply and exhaust the air in ventilation ducts. The DV-PP-L duct fans are an ideal solution for the air exhaust in bathrooms
More informationZehnder ComfoAir 550. Ventilation unit
Use The ventilation unit was specially developed for use in residential and commercial buildings with high ventilation demand. It combines maximum comfort, simple operation and high efficiency with flexible
More informationModel 655A Sizes
Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,
More informationAll DC Inverter Multi VRF
All DC Inverter Multi VRF In 2012, Gree highly promoted GMV5 All DC Inverter Multi VRF New breakthrough in comfort ability, intelligent control and design. Eight prominent advantages More powerful product
More informationMRXBOXAB-ECO3 MRXBOX-ECO3
NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due
More information1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A
Contents 1. Product Lineup... 1 2. External Appearance... 1 3. Nomenclature... 1 4. Features... 2 5. List of Functions... 3 6. Specifications... 6 7. Dimensional Drawings... 8 8. Wiring Diagrams... 9 9.
More informationMRXBOXAB-ECO2 MRXBOX-ECO2
NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due
More informationCommercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series
Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and
More informationLossnay RVX Fresh Series Air Ventilation
Lossnay RVX Fresh Series Air Ventilation Why do we need fresh air ventilation? Poor indoor air quality can be attributed to many problems inside a building. Excess humidity causes dampness, rot and mould,
More informationCASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS
SERVICE MANUAL MULTI COMBI OUTDOOR AND INDOOR UNITS CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS (36k,42k) COMBINATION TABLE (unit: kw) MC-E18AI MC-E24AI MC-E28AI MC-E36AI 1 model 2 models 2 models
More informationLimited Lifetime core warranty. 5-year warranty on balance of unit.
MODEL FEATURES Polypropylene HRV core 3 operating modes Painted galvanized steel case Designed for simple installation by a single person Fully insulated case Limited lifetime warranty on the heat recovery
More informationPRODUCT LINE-UP Residential & Light Commercial air conditioners
PRODUCT LINE-UP Residential & Light Commercial air conditioners Carrier air conditioning Energy savings Maximum energy savings thanks to accurate digital power control and super-efficient compressor. Comfort
More informationVENTILATION. Effective heat exchange and fresh air ventilation
VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is
More informationEnergy Recovery Ventilator
Energy Recovery Ventilator LG Electronics www.lg.com http://partner.lge.com Distributed by Copyright 2015 LG Electronics. All rights reserved. 2015 Eco_V Energy Recovery Ventilator Heat Exchanger Bypass
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationTechnical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.
Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual LCAC/2016.1 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Part 1. General Information... 1 1. Nomenclature...
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)
27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationAmerican Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit
American Brand with Global Reach Heat Pump Decorative Wall Mount Split Unit INT E G R ED HOME COMFORT TABLE OF CONTENTS Topic 1. Rheem Introduction 2. Core Technology 3. Nomenclature 4. Model Numbers 5.
More informationOthers ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units
PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E
More informationAdsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system
Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical
More informationCompact design & easy maintenance
Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)
LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationCASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU
CASSETTE DUCT TYPE FLOOR CEILING Light Commercial 18K BTU - 48K BTU 1-to-1 COMMERCIAL SERIES About our products The Tosot 1-to-1 commercial series of Air Conditioners was designed for applications where
More informationDC inverter VRF presentation
DC inverter VRF presentation NINGBO DEKON REFRIGERATION EQUIPMENT CO., LTD Wangchun Industrial Park, Yinzhou district,ningbo, China. Tel: 0086-574-88152763 Mob: 0086-15356475680 www.dekon-hvac.com Email:
More informationHEAT RECOVERY AND ENERGY RECOVERY VENTILATORS
HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact
More informationHeat Recovery Units. Heat Recovery 1
Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air
More informationDomestic & Commercial Fans
Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO
More informationVentZone Systems VentZone Zoned IAQ with Energy Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with
More informationDESIGN & TECHNICAL MANUAL
ENERGY RECOVERY VENTILATORS DESIGN & TECHNICAL MANUAL UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B DTO_ERV002E_01 2013.04.26 CONTENTS 1. SPECIFICATIONS 1-1. SPECIFICATIONS... 01-01 2. DIMENTIONS
More informationLeading edge reverse cycle air conditioning. Ducted and ceiling cassette
Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The
More informationAir conditioning. VRF systems
Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air conditioning VRF systems Systemair Trust We consider your trust in us as
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More information