1 Energy Recovery Ventilator LG Electronics Distributed by Copyright 2015 LG Electronics. All rights reserved.
2 2015 Eco_V Energy Recovery Ventilator Heat Exchanger Bypass and comfort is ensured through the highefficiency energy recovery central core which recovers energy from the indoor air and transfers it to the fresh incoming air without mixing airstream. Exhaust air Supply air ECO V automatically switches the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to the indoor/outdoor temperature. (Only applied to CMH or above) Enthalpy Heat Exchange Mode (Suer / Winter) Bypass Mode (Seasonal Change) Damper Damper Outdoor air Filter Indoor air Interlocking with Conditioning System - ECO V can be interlocked with air conditioners and controlled individually. - This function can be operated when the system is connected with a remote control. Cooling / Heating mode Set temperature Flexibility of Installation It s possible to install ECO V upside down when you need only one inspection hole. Compulsory Exhausting System The exhausting system using high static and sirocco fan removes contaminants effectively from indoor air. Supply and exhaust air flows are completely separated in the total heat exchanger, ECO V can filter out the impurities before supplying outdoor air and make indoor air fresh and healthy. Normal installation of 2 units Reverse installation of 1 unit (Left unit) Outdoors Indoors Damper Exhaust Return Exhaust Supply Outdoor Return Outdoor Total Heat Exchanger Supply Inspection chamber Top Top 02 03
3 2015 Eco_V Energy Recovery Ventilator Easy Cleaning and Filter Change It is easy and convenient to change and clean the filter. (Only applied to CMH or above) Fast Mode Fast ventilation mode prevents the spread of contaminants under negative indoor pressure, and makes indoor air fresh and comfortable quickly. Only Exhausting Fast Mode Eco V unit Remove side panel Exhausting and Supplying Simultaneously Supply Fan Exhausting operation causes negative indoor air pressure, and cannot fully ventilate. Exhaust Fan CO2 Concentration Control Using CO2 sensor, ECO V controls exhaust air flow automatically to keep indoor air fresh under settled CO2 concentration. Remove heat exchanger Change filer External Static Pressure Control Standard Wired CO2 Sensor (PES-C0RV0) The high static pressure fan can control the air volume depending on the length of the duct. It is also easy to control the pressure level by using the remote controller for a more flexible duct installation and easier testing. Volume H M L CO2 (ppm) 2, Closed Open Closed Open M L H 1,000 OFF ON External Static Pressure (Aq) 0 Time (min) 04 05
4 LZ-H025GBA3 LZ-H035GBA3 LZ-H050GBA2 LZ-H080GBA2 LZ-HGBA2 LZ-H150GBA2 LZ-HGBA2 LZ-H025GBA3 LZ-H035GBA3 LZ-H050GBA2 LZ-H080GBA2 / LZ-HGBA2 LZ-H150GBA2 / LZ-HGBA2 Model LZ-H025GBA3 LZ-H035GBA3 LZ-H050GBA2 Nominal Capacity CMH(CFM) 250(147) 350(206) (294) Power Supply ø/v/hz 1, , Step SH/H/L - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps 1.45/1.20/ /1.55/ /1.58/0.79 Power input SH/H/L W 167/135/83 210/183/90 230/220/85 Flow SH/H/L CMH(CFM) 250/250/ /350/210 //320 (147/147/88) (206/206/124) (294/294/124) ECO V Mode 150/130/ 170/150/ 150//50 External Static Pressure SH/H/L Pa(InWTR) (0.60/0.52/0.40) (0.68/0.60/0.40) (0.60/0.40/0.20) Temperature Exchange SH/H/L % 81/81/85 83/83/87 75/75/76 Enthalpy Exchange Heating(SH/H/L) % 74/74/78 76/76/80 72/72/74 Cooling(SH/H/L) % 62/62/68 66/66/73 70/70/72 Noise Level (Sound Level, 1.5m) SH/H/L db(a) 36/35/28 36/35/28 34/32/25 Step SH/H/L - - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps /1.58/0.79 Power input SH/H/L W - 230/220/85 Bypass Mode Flow SH/H/L CMH(CFM) - //320 (294/294/124) External Static Pressure SH/H/L Pa(InWTR) - 150//50 (0.60/0.40/0.20) Noise Level (Sound Level, 1.5m) SH/H/L db(a) - 34/35/25 Heat Exchanger Type - Crossflow Net Weight kg Dimension WxHxD 750x250x x350x x273x1,014 Duct Work* Qty EA 4 Size(ø) ø150 ø Supply Fan Qty EA 1 Exhaust Fan Qty EA 1 Qty EA 2 Filters Type - Cleanable Size(WxHxD) 370x10x x10x x10x166 Refer to the below Wired table Dry Contact Simple (1 Contact point without case) PQDSA Simple (1 Contact point with case) PDRYCB000 Note : 1. ECO V mode : Total Heat Recovery mode 2. * : Refer to dimensional drawings. 3. Noise level : - The operating conditions are assumed to be standard - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction (acoustic absorption coefficient) of particular room in which the equipment is installed. - The sound level at the air discharge port is about 8 db(a) higher than the unit's operating sound. 4. Temperature and Enthalpy Exchange at cooling Indoor Temperature : 27ºC DB, 19ºC WB, Outdoor Temperature : 35ºC DB, 29ºC WB 5. Temperature and Enthalpy Exchange at heating Indoor Temperature : 20ºC DB, 14ºC WB, Outdoor Temperature : 5ºC DB, 2ºC WB 6. This product contains Fluorinated Greenhouse Gases. (R410A) Model LZ-H080GBA2 LZ-HGBA2 LZ-H150GBA2 LZ-HGBA2 Nominal Capacity CMH(CFM) 800(471) 1,000(589) 1,(883) 2,000(1,177) Power Supply ø/v/hz 1, , Step SH/H/L - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps 2.77/2.16/ /2.91/ /5.40/ /5.90/3.60 Power input SH/H/L W 360/270/ /385/ /540/ /770/420 Flow SH/H/L CMH(CFM) 800/800/660 1,000/1,000/800 1,/1,/1, 2,000/2,000/1,600 (471/471/388) (589/589/471) (883/883/706) (1,177/1,177/942) ECO V Mode /110/60 160/90/50 /110/60 160/90/50 External Static Pressure SH/H/L Pa(InWTR) (0.80/0.44/0.24) (0.64/0.36/0.20) (0.80/0.44/0.24) (0.64/0.36/0.20) Temperature Exchange SH/H/L % 79/79/82 75/75/78 79/79/82 75/75/78 Enthalpy Exchange Heating(SH/H/L) % 67/67/69 64/64/66 67/67/69 64/64/66 Cooling(SH/H/L) % 50/50/53 45/45/50 50/50/53 45/45/50 Noise Level (Sound Level, 1.5m) SH/H/L db(a) 36/34/30 37/35/31 39/37/33 39/37/33 Step SH/H/L - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps 2.77/2.16/ /2.91/ /5.40/ /5.90/3.60 Power input SH/H/L W 360/370/ /385/ /540/ /770/420 Bypass Mode Flow SH/H/L CMH(CFM) 800/800/660 1,000/1,000/800 1,/1,/1, 2,000/2,000/1,600 (471/471/388) (589/589/471) (883/883/706) (1,177/1,177/942) External Static Pressure SH/H/L Pa(InWTR) /110/60 160/90/50 /110/60 160/90/50 (0.80/0.44/0.24) (0.64/0.36/0.20) (0.80/0.44/0.24) (0.64/0.36/0.20) Noise Level (Sound Level, 1.5m) SH/H/L db(a) 36/34/30 37/35/31 Heat Exchanger Type - Crossflow Net Weight kg Dimension WxHxD 1,062x365x1,140 1,313x738x1,140 Duct Work* Qty EA Size(ø) ø250 ø250+ø350 Supply Fan Qty EA 1 2 Exhaust Fan Qty EA 1 2 Qty EA 2 4 Filters Type - Cleanable Size(WxHxD) 1,056x10x212.5 Refer to the below Wired table Dry Contact Simple (1 Contact point without case) PQDSA Simple (1 Contact point with case) PDRYCB000 Note : 1. ECO V mode : Total Heat Recovery mode 2. * : Refer to dimensional drawings. 3. Noise level : - The operating conditions are assumed to be standard - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction (acoustic absorption coefficient) of particular room in which the equipment is installed. - The sound level at the air discharge port is about 8 db(a) higher than the unit's operating sound. 4. Temperature and Enthalpy Exchange at cooling Indoor Temperature : 27ºC DB, 19ºC WB, Outdoor Temperature : 35ºC DB, 29ºC WB 5. Temperature and Enthalpy Exchange at heating Indoor Temperature : 20ºC DB, 14ºC WB, Outdoor Temperature : 5ºC DB, 2ºC WB 6. This product contains Fluorinated Greenhouse Gases. (R410A) Wired Premium Standard II Standard Wired Premium Standard II Standard PREMTA000 PREMTA000A PREMTA000B PREMTB001 PREMTBB01 PQRCVSL0QW PQRCVSL0 PREMTA000 PREMTA000A PREMTA000B PREMTB001 PREMTBB01 PQRCVSL0QW PQRCVSL
5 LZ-H025GBA Super Exchange (%) LZ-H080GBA2 Super Exchange (%) LZ-H035GBA3 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) LZ-HGBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) Super Exchange (%) Super Exchange (%) LZ-H050GBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) LZ-H150GBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) Super- Exchange (%) 75% 65% 55% Super- Exchange (%) Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) LZ-HGBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) Super- Exchange (%) Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling)
6 LZ-H050GXH0 LZ-H080GXH0 LZ-HGXH0 LZ-H050GXN0 LZ-H080GXN0 LZ-HGXN0 Energy Recovery Ventilator Providing Cool & Warm Fresh ECO V DX has some air conditioning funtions. During the suer, it can transform outdoor warm air into cool air for indoors, and it can prevent cold drafts during the winter by supplying warm air. Cooling Heating Total Conditioning Solution ECO V DX can be used as a Total Conditioning Solution. It can control condition of incoming air with the DX coil and humidifier for making comfortable indoor air. In the suer, ECO V DX controls the air indoors by cooling and dehumidifying incoming air. In winter, it can provide warm air by heating and humidifying the incoming air. Heat exchange DX Coil Humidification Exhaust Supply Outdoor Return LZ-H050GXH0 LZ-H080GXH0 LZ-HGXH0 LZ-050GXN0 LZ-080GXN0 LZ-HGXN0 Cooling1) Fresh Conditioning Load Heating2) Temperature Exchange SH/H/L % Cooling (SH/H/L) % Enthalpy Exchange Heating (SH/H/L) % CMH Flow Rate CMH Fan External Static Pressure (SH/H/L) Pa System Humidifier Amount3) kg/h Pressure Feed Water Mpa db(a) Sound Pressure db(a) Refrigerant Power Supply ø/v/hz Power Input (Norminal) A Nominal Running Current (RLA) A Dimensions WxHxD Net Weight kg Liquid Gas Pipe Connection Water Drain (Outer Diameter) Connection Duct Diameter Simple (1 Contact point without case) Simple (1 Contact point with case) Dry Contact 2 Contact point For Thermostat (On-off/Mode/Fan speed) Modbus Counication /86/87 80/80/81 76/76/78 86/86/87 80/80/81 76/76/78 61/61/63 50/50/53 45/45/50 61/61/63 50/50/53 45/45/50 76/76/77 67/67/69 64/64/66 76/76/77 67/67/69 64/64/66 // /800/640 1,000/1,000/820 // /800/640 1,000/1,000/820 // /800/640 1,000/1,000/820 // /800/640 1,000/1,000/ /120/ 140/90/70 110/70/60 180/150/ /120/80 150//70 Natural Evaporating Type ~ /36/33 39/37/34 40/38/35 39/37/35 41/38/36 41/39/36 39/37/34 40/38/35 40/38/35 39/37/35 41/38/36 41/39/36 R410A R410A 1 / 220 ~240 / 50 1 / 220 ~240 / /0.20/ /0.35/ /0.42/ /0.20/ /0.35/ /0.42/ /0.20/ /0.35/ /0.42/ /0.20/ /0.35/ /0.42/0.27 1,667 x 365 x 1,140 1,667 x 365 x 1, ø6.35 ø6.35 ø12.7 ø12.7 ø6.35 ø25.4 ø25.4 ø250 ø250 Refer to the below Wired table PQDSA PDRYCB000 PDRYCB PDRYCB PDRYCB Note : 1) Cooling Capacity Test condition : Indoor temperature : 27 C DB, 19 C WB, Outdoor temperature : 35 C DB 2) Heating Capacity Test condition : Indoor temperature : 20 C DB, Outdoor temperature : 7 C DB, 6 C WB 3) Humidifying capacity is based on the following conditions : Indoor temperature : 20 C DB, 15 C WB, Outdoor temperature : 7 C DB, 6 C WB * Cooling and heating capacities are based on the following conditions. : Fan is based on and Super-high. The figures in the parenthesis indicate the heat reclaimed from the heat recovery ventilator. * The operating sound measured at the point 1.5 m below the center of the unit is converted to that measured at an anechoic chamber built in accordance with the KS B 6879 conditions. * The actual operating sound varies depending on the surrounding conditions (near running unit's sound, reflected sound and so on) and is normally higher than this value. * flow rate can be changed over to low mode or high mode. * The specifications, designs and information here are subject to change without notice. * This product contains Fluorinated Greenhouse Gases. (R410A) Interlocking with MULTI V ECO V DX can be interlocked with MULTI V. It can be controlled individually by a wired remote controller connected to MULTI V indoor units. Indoor Units Model eco V DX Wired Premium Outdoor 10 PREMTA000 PREMTA000A PREMTA000B Standard II PREMTB001 Standard PREMTBB01 PQRCVSL0QW PQRCVSL0 11
Heat Recovery Ventilator with DX Coil 0CED0-01B(Replaces: 0CED0-01A)
0CED0-01B(Replaces: 0CED0-01A) 0CED0-01B(Replaces: 0CED0-01A) 1. External Appearance 2. Models List 3. Model Number Nomenclature 4. Structures 5. Specifications 6. Dimensions 7. Piping Diagrams 8. Wiring
More informationHeat Recovery Ventilator with DX Coil 0CED0-01A
0CED0-01A 0CED0-01A 1. External Appearance 2. Models List 3. Model Number Nomenclature 4. Structures 5. Specifications 6. Dimensions 7. Wiring Diagram 8. Fan Performance 9. Capacity Tables 10. Sound Level
More informationPRODUCT RANGE: ROOFTOP PACKAGE
Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More informationHeat pump and energy recovery systems
SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air
More informationVERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons
491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED
More informationAdsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system
Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical
More informationSi Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1
Si71-812 Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1 Heat Reclaim Ventilation - with DX coil - VKM 50GAV1 VKM 80GAV1
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More informationLG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.
LG AIR CONDITIONERS Ducted Split System Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)
27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationOthers ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units
PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E
More informationPackage Hygienic Air Handling Units. PHK Series
Package Hygienic Air Handling Units PHK Series 1 PHK Series PHK : Standard PHK HP : Heat Pump PHK TO : Clean Room Air Handling Unit Up to 11.000 m 3 /h Airflow Complying with DiN 1946/4 Hygiene Criteria
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More informationSamsung Air Conditioning
Samsung Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and grow in
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)
LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More information48PGD/E/F/L/M/N PG20-28
48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More informationAdconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h
Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More information1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA
PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air
More informationLG AIR CONDITIONERS Ducted Split System. Clean, Quiet & Comfortable with LG HVAC.
LG AIR CONDITIONERS Ducted Split System Clean, Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive
More information9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners
PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,
More informationHeat Recovery Units. Heat Recovery 1
Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air
More informationHitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Set Free VRF Systems Mini 2-pipe S i d e fl o w2 - p i p e Modular 2 or 3-pipe Std - Efficiency Hi-Efficiency
More informationAIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions
217 AIR-TO-AIR HEAT EXCHANGERS Air Treatment Solutions AIR TREATMENT SOLUTIONS 2 I TOSHIBA Ventilation - the key to enhanced quality of life Air pollution has become a serious worldwide problem. In urban
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationAlpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018
Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................
More informationSINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU
SINGLE Technical Data Book PAC for Europe (R4A, 5Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU History Version Modification Date Remark Ver 1. Release SINGLE PAC for Europe (R4A, 5Hz) 16.7.15 - Index 1
More informationResolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h
Comfort air conditioning unit with highly efficient regenerative heat storage packages 62 26 01 - simplified illustration Automatically selects the most economical operating mode! 62 and 66 AIR OLUME FLOW:
More information20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR
ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationMidea Ducted and Cassette Split Systems. Year round comfort, all around the house.
Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationSamsung EHS, XL Range of Commercial Air to water heat pumps
Samsung EHS, XL Range of Commercial Air to water heat pumps 2018 Freedom Heat Pumps Spec and price Guide Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered
More informationSEQUENCE OF OPERATIONS
SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,
More informationSUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer
SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More information[U] Serie MHB / MHA Manual de Ingeniería
[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationyour comfort. our world. Ventilation Catalogue Heating Ventilation Integrated Solutions Air Conditioning Refrigeration
your comfort. our world. Ventilation Catalogue Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Daikin Europe N.V. ABOUT DaiKIN Daikin has a worldwide reputation based on almost
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationVentilation. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration
Ventilation All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration Daikin Europe N.V. ABOUT DAIKIN Daikin has a worldwide reputation based on almost 85 years experience
More informationHeat Recovery Ventilator
REKUPETORI Heat Recovery Ventilator Heat recovery ventilator Larger air supply rate enhanced heat exchange efficiency enhanced energy saving property The heat recovery ventilator (HRV) can reclaim heat
More informationHeat Reclaim Ventilation. VRV Air Handling Applications. a wide variety of daikin solutions. ventilation systems
Heat Reclaim Ventilation ventilation systems Outdoor Air Processing Unit VRV Air Handling Applications www.daikin.eu a wide variety of daikin solutions for the provision of fresh air and ventilation Daikin
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering
ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery Steven T. Taylor, PE Principal Taylor Engineering This program is registered with the AIA/CES for continuing professional education.
More informationVentilation. Product catalogue 2019 for professionals
Ventilation Product catalogue 2019 for professionals Fresh air for the residential and commercial sector Heat reclaim ventilation and air handling applications Including new Modular L MODULAR L (SMART)
More informationSINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL
SINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL 3/4, 1, 1-1/2, and 2 Tons Mega Inverter Models: LS090HEV1 LS120HEV1 LS180HEV1 LS240HEV1 3/4 and 1 Tons Mega 115V Models: LS090HXV LS120HXV PROPRIETARY DATA
More informationFAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney
FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1
More informationSUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER
SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER Energy Recovery Ventilation Specialist Beijing Holtop Artificial Environment Technology Co., Ltd ISO 9001: 2000 Approved Company COMPANY BRIEF INTRODUCTION
More informationAdding More Fan Power Can Be a Good Thing
This article was published in ASHE Journal, May 14. Copyright 14 ASHE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of
More informationIntroduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN
Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationVENTILATION. Effective heat exchange and fresh air ventilation
VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is
More informationIntegrated VarIable refrigerant flow ahu/pau (r410a)
Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14
More informationPackaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N
Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification
More informationMonobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.
Monobloc LG Electronics Commercial Air Conditioning 56, Digital-ro 10-gil, Geumcheon-gu, Seoul, Korea www.lg.com http://partner.lge.com http://www.lgethermav.com Distributed by Copyright 2018 LG Electronics.
More informationMystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)
Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationVERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN
VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationWhole Home Heat Recovery Ventilation
Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay
More information48TM GAS HEATING/ELECTRIC COOLING UNITS
48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Buda, Texas 2a New Construction Construction
More informationImproving your home comfort by enhancing the air
i n d o o r a i r q u a l i t y Improving your home comfort by enhancing the air The perfect answer to air quality problems? Healthy Climate Solutions. With fuel and electricity costs on the rise, today
More informationAIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h
COMFORT ROOFTOP UNITS AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM 10000 TO 45000 m3/h climaveneta.com COMFORT ROOFTOP UNITS ENGINEERED FOR MAXIMUM EFFICIENCY AND VERSATILITY
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationGUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.
Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the
More informationPUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling
PUT WASTE HEAT TO USE with our gas-heated steam humidifier, Humidification and evaporative cooling Cost-effective and eco-friendly steam production with gas as the primary energy source Touch Controller
More informationVentilation Unit Zehnder ComfoAir 350
Use The ComfoAir 350 ventilation unit was developed for residential and small commercial buildings. It combines maximum comfort, simple operation and very high efficiency. The CA350 moves up to 218 cfm
More information48TF GAS HEATING/ ELECTRIC COOLING UNITS
48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationWALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.
WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationHeat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing
Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation
More informationCHAPTER 4. HVAC DELIVERY SYSTEMS
CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer
More informationHEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS
HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More informationPackaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R
Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in
More informationClassic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA
Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationWORKSHOP VENTILATION- PSYCHROMETRICS-AHU
Alkis Triantafyllopoulos Mechanical Engineer Member TEE, MASHRAE a.trianta@gmail.com WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Based on ASHRAE 62 Purpose Set minimum Outdoor Air ventilation Rates Air Quality
More informationSINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL
SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL Single-Zone Ceiling-Concealed Ducted Heat Pump Systems 3/4 to 3 Tons Low Static LD097HV4 (9,000 Btu/h) LD127HV4 (12,000 Btu/h) High Static
More informationINDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying
INDUSTRIAL DEHUMIDIFIERS Advanced range of compressor and desiccant dehumidifiers Dehumidification and drying To room From room Fan Regeneration heater Dry process air Regeneration air Regeneration area
More informationCompact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N
Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: N-27661 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products
More informationFresh Air Ventilation
Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key
More informationFresh Air Ventilation
Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key
More informationHeat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:
Heat Pumps M2 SERIES Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Water-source and geothermal heat pump self-contained units with capacities from 3-70 tons 10%-100% variable
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationMODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit
MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main
More informationSubmitted to Reference Approval Construction Unit Designation Schedule #
Page 1of5 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Modules Connected US Ton (nominal) Capacity (Btu/h) System Specifications
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationHRV Heat Reclaim Ventilation. FXMQ-MFV1 Outdoor Air Processing Unit. VRV+EXV-kit VRV Air Handling Applications
Ventilation HRV Heat Reclaim Ventilation FXMQ-MFV1 Outdoor Air Processing Unit VRV+EXV-kit VRV Air Handling Applications c o n t e n t s p. 3 Table of Contents INTRODUCTION 4 HRV - HEAT RECLAIM VENTILATION
More informationThe ultimate fresh air solution.
Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged
More informationHVAC Mandatory Provisions Part II, Page 1
HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationLearn more about Samsung air conditioner at:
Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner 2015 SAMSUNG New Single Air-Conditioner SINGLE SINGLE is a smart choice for saving both money and energy.
More informationA GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA
A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet
More informationLossnay. Total Heat Exchangers
Lossnay Total Heat Exchangers Air Conditioning Domestic Heating Commercial Heating Photovoltaics Simple and Effective Fresh air from outside Excellent Air Quality and Unbeatable Heat Exchange Efficiency