Energy Recovery Ventilator

Size: px
Start display at page:

Download "Energy Recovery Ventilator"

Transcription

1 Energy Recovery Ventilator LG Electronics Distributed by Copyright 2015 LG Electronics. All rights reserved.

2 2015 Eco_V Energy Recovery Ventilator Heat Exchanger Bypass and comfort is ensured through the highefficiency energy recovery central core which recovers energy from the indoor air and transfers it to the fresh incoming air without mixing airstream. Exhaust air Supply air ECO V automatically switches the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to the indoor/outdoor temperature. (Only applied to CMH or above) Enthalpy Heat Exchange Mode (Suer / Winter) Bypass Mode (Seasonal Change) Damper Damper Outdoor air Filter Indoor air Interlocking with Conditioning System - ECO V can be interlocked with air conditioners and controlled individually. - This function can be operated when the system is connected with a remote control. Cooling / Heating mode Set temperature Flexibility of Installation It s possible to install ECO V upside down when you need only one inspection hole. Compulsory Exhausting System The exhausting system using high static and sirocco fan removes contaminants effectively from indoor air. Supply and exhaust air flows are completely separated in the total heat exchanger, ECO V can filter out the impurities before supplying outdoor air and make indoor air fresh and healthy. Normal installation of 2 units Reverse installation of 1 unit (Left unit) Outdoors Indoors Damper Exhaust Return Exhaust Supply Outdoor Return Outdoor Total Heat Exchanger Supply Inspection chamber Top Top 02 03

3 2015 Eco_V Energy Recovery Ventilator Easy Cleaning and Filter Change It is easy and convenient to change and clean the filter. (Only applied to CMH or above) Fast Mode Fast ventilation mode prevents the spread of contaminants under negative indoor pressure, and makes indoor air fresh and comfortable quickly. Only Exhausting Fast Mode Eco V unit Remove side panel Exhausting and Supplying Simultaneously Supply Fan Exhausting operation causes negative indoor air pressure, and cannot fully ventilate. Exhaust Fan CO2 Concentration Control Using CO2 sensor, ECO V controls exhaust air flow automatically to keep indoor air fresh under settled CO2 concentration. Remove heat exchanger Change filer External Static Pressure Control Standard Wired CO2 Sensor (PES-C0RV0) The high static pressure fan can control the air volume depending on the length of the duct. It is also easy to control the pressure level by using the remote controller for a more flexible duct installation and easier testing. Volume H M L CO2 (ppm) 2, Closed Open Closed Open M L H 1,000 OFF ON External Static Pressure (Aq) 0 Time (min) 04 05

4 LZ-H025GBA3 LZ-H035GBA3 LZ-H050GBA2 LZ-H080GBA2 LZ-HGBA2 LZ-H150GBA2 LZ-HGBA2 LZ-H025GBA3 LZ-H035GBA3 LZ-H050GBA2 LZ-H080GBA2 / LZ-HGBA2 LZ-H150GBA2 / LZ-HGBA2 Model LZ-H025GBA3 LZ-H035GBA3 LZ-H050GBA2 Nominal Capacity CMH(CFM) 250(147) 350(206) (294) Power Supply ø/v/hz 1, , Step SH/H/L - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps 1.45/1.20/ /1.55/ /1.58/0.79 Power input SH/H/L W 167/135/83 210/183/90 230/220/85 Flow SH/H/L CMH(CFM) 250/250/ /350/210 //320 (147/147/88) (206/206/124) (294/294/124) ECO V Mode 150/130/ 170/150/ 150//50 External Static Pressure SH/H/L Pa(InWTR) (0.60/0.52/0.40) (0.68/0.60/0.40) (0.60/0.40/0.20) Temperature Exchange SH/H/L % 81/81/85 83/83/87 75/75/76 Enthalpy Exchange Heating(SH/H/L) % 74/74/78 76/76/80 72/72/74 Cooling(SH/H/L) % 62/62/68 66/66/73 70/70/72 Noise Level (Sound Level, 1.5m) SH/H/L db(a) 36/35/28 36/35/28 34/32/25 Step SH/H/L - - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps /1.58/0.79 Power input SH/H/L W - 230/220/85 Bypass Mode Flow SH/H/L CMH(CFM) - //320 (294/294/124) External Static Pressure SH/H/L Pa(InWTR) - 150//50 (0.60/0.40/0.20) Noise Level (Sound Level, 1.5m) SH/H/L db(a) - 34/35/25 Heat Exchanger Type - Crossflow Net Weight kg Dimension WxHxD 750x250x x350x x273x1,014 Duct Work* Qty EA 4 Size(ø) ø150 ø Supply Fan Qty EA 1 Exhaust Fan Qty EA 1 Qty EA 2 Filters Type - Cleanable Size(WxHxD) 370x10x x10x x10x166 Refer to the below Wired table Dry Contact Simple (1 Contact point without case) PQDSA Simple (1 Contact point with case) PDRYCB000 Note : 1. ECO V mode : Total Heat Recovery mode 2. * : Refer to dimensional drawings. 3. Noise level : - The operating conditions are assumed to be standard - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction (acoustic absorption coefficient) of particular room in which the equipment is installed. - The sound level at the air discharge port is about 8 db(a) higher than the unit's operating sound. 4. Temperature and Enthalpy Exchange at cooling Indoor Temperature : 27ºC DB, 19ºC WB, Outdoor Temperature : 35ºC DB, 29ºC WB 5. Temperature and Enthalpy Exchange at heating Indoor Temperature : 20ºC DB, 14ºC WB, Outdoor Temperature : 5ºC DB, 2ºC WB 6. This product contains Fluorinated Greenhouse Gases. (R410A) Model LZ-H080GBA2 LZ-HGBA2 LZ-H150GBA2 LZ-HGBA2 Nominal Capacity CMH(CFM) 800(471) 1,000(589) 1,(883) 2,000(1,177) Power Supply ø/v/hz 1, , Step SH/H/L - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps 2.77/2.16/ /2.91/ /5.40/ /5.90/3.60 Power input SH/H/L W 360/270/ /385/ /540/ /770/420 Flow SH/H/L CMH(CFM) 800/800/660 1,000/1,000/800 1,/1,/1, 2,000/2,000/1,600 (471/471/388) (589/589/471) (883/883/706) (1,177/1,177/942) ECO V Mode /110/60 160/90/50 /110/60 160/90/50 External Static Pressure SH/H/L Pa(InWTR) (0.80/0.44/0.24) (0.64/0.36/0.20) (0.80/0.44/0.24) (0.64/0.36/0.20) Temperature Exchange SH/H/L % 79/79/82 75/75/78 79/79/82 75/75/78 Enthalpy Exchange Heating(SH/H/L) % 67/67/69 64/64/66 67/67/69 64/64/66 Cooling(SH/H/L) % 50/50/53 45/45/50 50/50/53 45/45/50 Noise Level (Sound Level, 1.5m) SH/H/L db(a) 36/34/30 37/35/31 39/37/33 39/37/33 Step SH/H/L - SUPER-HIGH / HIGH / LOW Current SH/H/L Amps 2.77/2.16/ /2.91/ /5.40/ /5.90/3.60 Power input SH/H/L W 360/370/ /385/ /540/ /770/420 Bypass Mode Flow SH/H/L CMH(CFM) 800/800/660 1,000/1,000/800 1,/1,/1, 2,000/2,000/1,600 (471/471/388) (589/589/471) (883/883/706) (1,177/1,177/942) External Static Pressure SH/H/L Pa(InWTR) /110/60 160/90/50 /110/60 160/90/50 (0.80/0.44/0.24) (0.64/0.36/0.20) (0.80/0.44/0.24) (0.64/0.36/0.20) Noise Level (Sound Level, 1.5m) SH/H/L db(a) 36/34/30 37/35/31 Heat Exchanger Type - Crossflow Net Weight kg Dimension WxHxD 1,062x365x1,140 1,313x738x1,140 Duct Work* Qty EA Size(ø) ø250 ø250+ø350 Supply Fan Qty EA 1 2 Exhaust Fan Qty EA 1 2 Qty EA 2 4 Filters Type - Cleanable Size(WxHxD) 1,056x10x212.5 Refer to the below Wired table Dry Contact Simple (1 Contact point without case) PQDSA Simple (1 Contact point with case) PDRYCB000 Note : 1. ECO V mode : Total Heat Recovery mode 2. * : Refer to dimensional drawings. 3. Noise level : - The operating conditions are assumed to be standard - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction (acoustic absorption coefficient) of particular room in which the equipment is installed. - The sound level at the air discharge port is about 8 db(a) higher than the unit's operating sound. 4. Temperature and Enthalpy Exchange at cooling Indoor Temperature : 27ºC DB, 19ºC WB, Outdoor Temperature : 35ºC DB, 29ºC WB 5. Temperature and Enthalpy Exchange at heating Indoor Temperature : 20ºC DB, 14ºC WB, Outdoor Temperature : 5ºC DB, 2ºC WB 6. This product contains Fluorinated Greenhouse Gases. (R410A) Wired Premium Standard II Standard Wired Premium Standard II Standard PREMTA000 PREMTA000A PREMTA000B PREMTB001 PREMTBB01 PQRCVSL0QW PQRCVSL0 PREMTA000 PREMTA000A PREMTA000B PREMTB001 PREMTBB01 PQRCVSL0QW PQRCVSL

5 LZ-H025GBA Super Exchange (%) LZ-H080GBA2 Super Exchange (%) LZ-H035GBA3 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) LZ-HGBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) Super Exchange (%) Super Exchange (%) LZ-H050GBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) LZ-H150GBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) Super- Exchange (%) 75% 65% 55% Super- Exchange (%) Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) LZ-HGBA2 Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling) Super- Exchange (%) Temperature Exchange Enthalpy Exchange (heating) Enthalpy Exchange (cooling)

6 LZ-H050GXH0 LZ-H080GXH0 LZ-HGXH0 LZ-H050GXN0 LZ-H080GXN0 LZ-HGXN0 Energy Recovery Ventilator Providing Cool & Warm Fresh ECO V DX has some air conditioning funtions. During the suer, it can transform outdoor warm air into cool air for indoors, and it can prevent cold drafts during the winter by supplying warm air. Cooling Heating Total Conditioning Solution ECO V DX can be used as a Total Conditioning Solution. It can control condition of incoming air with the DX coil and humidifier for making comfortable indoor air. In the suer, ECO V DX controls the air indoors by cooling and dehumidifying incoming air. In winter, it can provide warm air by heating and humidifying the incoming air. Heat exchange DX Coil Humidification Exhaust Supply Outdoor Return LZ-H050GXH0 LZ-H080GXH0 LZ-HGXH0 LZ-050GXN0 LZ-080GXN0 LZ-HGXN0 Cooling1) Fresh Conditioning Load Heating2) Temperature Exchange SH/H/L % Cooling (SH/H/L) % Enthalpy Exchange Heating (SH/H/L) % CMH Flow Rate CMH Fan External Static Pressure (SH/H/L) Pa System Humidifier Amount3) kg/h Pressure Feed Water Mpa db(a) Sound Pressure db(a) Refrigerant Power Supply ø/v/hz Power Input (Norminal) A Nominal Running Current (RLA) A Dimensions WxHxD Net Weight kg Liquid Gas Pipe Connection Water Drain (Outer Diameter) Connection Duct Diameter Simple (1 Contact point without case) Simple (1 Contact point with case) Dry Contact 2 Contact point For Thermostat (On-off/Mode/Fan speed) Modbus Counication /86/87 80/80/81 76/76/78 86/86/87 80/80/81 76/76/78 61/61/63 50/50/53 45/45/50 61/61/63 50/50/53 45/45/50 76/76/77 67/67/69 64/64/66 76/76/77 67/67/69 64/64/66 // /800/640 1,000/1,000/820 // /800/640 1,000/1,000/820 // /800/640 1,000/1,000/820 // /800/640 1,000/1,000/ /120/ 140/90/70 110/70/60 180/150/ /120/80 150//70 Natural Evaporating Type ~ /36/33 39/37/34 40/38/35 39/37/35 41/38/36 41/39/36 39/37/34 40/38/35 40/38/35 39/37/35 41/38/36 41/39/36 R410A R410A 1 / 220 ~240 / 50 1 / 220 ~240 / /0.20/ /0.35/ /0.42/ /0.20/ /0.35/ /0.42/ /0.20/ /0.35/ /0.42/ /0.20/ /0.35/ /0.42/0.27 1,667 x 365 x 1,140 1,667 x 365 x 1, ø6.35 ø6.35 ø12.7 ø12.7 ø6.35 ø25.4 ø25.4 ø250 ø250 Refer to the below Wired table PQDSA PDRYCB000 PDRYCB PDRYCB PDRYCB Note : 1) Cooling Capacity Test condition : Indoor temperature : 27 C DB, 19 C WB, Outdoor temperature : 35 C DB 2) Heating Capacity Test condition : Indoor temperature : 20 C DB, Outdoor temperature : 7 C DB, 6 C WB 3) Humidifying capacity is based on the following conditions : Indoor temperature : 20 C DB, 15 C WB, Outdoor temperature : 7 C DB, 6 C WB * Cooling and heating capacities are based on the following conditions. : Fan is based on and Super-high. The figures in the parenthesis indicate the heat reclaimed from the heat recovery ventilator. * The operating sound measured at the point 1.5 m below the center of the unit is converted to that measured at an anechoic chamber built in accordance with the KS B 6879 conditions. * The actual operating sound varies depending on the surrounding conditions (near running unit's sound, reflected sound and so on) and is normally higher than this value. * flow rate can be changed over to low mode or high mode. * The specifications, designs and information here are subject to change without notice. * This product contains Fluorinated Greenhouse Gases. (R410A) Interlocking with MULTI V ECO V DX can be interlocked with MULTI V. It can be controlled individually by a wired remote controller connected to MULTI V indoor units. Indoor Units Model eco V DX Wired Premium Outdoor 10 PREMTA000 PREMTA000A PREMTA000B Standard II PREMTB001 Standard PREMTBB01 PQRCVSL0QW PQRCVSL0 11

Heat Recovery Ventilator with DX Coil 0CED0-01B(Replaces: 0CED0-01A)

Heat Recovery Ventilator with DX Coil 0CED0-01B(Replaces: 0CED0-01A) 0CED0-01B(Replaces: 0CED0-01A) 0CED0-01B(Replaces: 0CED0-01A) 1. External Appearance 2. Models List 3. Model Number Nomenclature 4. Structures 5. Specifications 6. Dimensions 7. Piping Diagrams 8. Wiring

More information

Heat Recovery Ventilator with DX Coil 0CED0-01A

Heat Recovery Ventilator with DX Coil 0CED0-01A 0CED0-01A 0CED0-01A 1. External Appearance 2. Models List 3. Model Number Nomenclature 4. Structures 5. Specifications 6. Dimensions 7. Wiring Diagram 8. Fan Performance 9. Capacity Tables 10. Sound Level

More information

PRODUCT RANGE: ROOFTOP PACKAGE

PRODUCT RANGE: ROOFTOP PACKAGE Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical

More information

Si Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1

Si Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1 Si71-812 Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1 Heat Reclaim Ventilation - with DX coil - VKM 50GAV1 VKM 80GAV1

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC. LG AIR CONDITIONERS Ducted Split System Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E

More information

Package Hygienic Air Handling Units. PHK Series

Package Hygienic Air Handling Units. PHK Series Package Hygienic Air Handling Units PHK Series 1 PHK Series PHK : Standard PHK HP : Heat Pump PHK TO : Clean Room Air Handling Unit Up to 11.000 m 3 /h Airflow Complying with DiN 1946/4 Hygiene Criteria

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

Samsung Air Conditioning

Samsung Air Conditioning Samsung Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and grow in

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode) LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

LG AIR CONDITIONERS Ducted Split System. Clean, Quiet & Comfortable with LG HVAC.

LG AIR CONDITIONERS Ducted Split System. Clean, Quiet & Comfortable with LG HVAC. LG AIR CONDITIONERS Ducted Split System Clean, Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Set Free VRF Systems Mini 2-pipe S i d e fl o w2 - p i p e Modular 2 or 3-pipe Std - Efficiency Hi-Efficiency

More information

AIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions

AIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions 217 AIR-TO-AIR HEAT EXCHANGERS Air Treatment Solutions AIR TREATMENT SOLUTIONS 2 I TOSHIBA Ventilation - the key to enhanced quality of life Air pollution has become a serious worldwide problem. In urban

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018 Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................

More information

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU SINGLE Technical Data Book PAC for Europe (R4A, 5Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU History Version Modification Date Remark Ver 1. Release SINGLE PAC for Europe (R4A, 5Hz) 16.7.15 - Index 1

More information

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 62 26 01 - simplified illustration Automatically selects the most economical operating mode! 62 and 66 AIR OLUME FLOW:

More information

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Samsung EHS, XL Range of Commercial Air to water heat pumps

Samsung EHS, XL Range of Commercial Air to water heat pumps Samsung EHS, XL Range of Commercial Air to water heat pumps 2018 Freedom Heat Pumps Spec and price Guide Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

[U] Serie MHB / MHA Manual de Ingeniería

[U] Serie MHB / MHA Manual de Ingeniería [U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

your comfort. our world. Ventilation Catalogue Heating Ventilation Integrated Solutions Air Conditioning Refrigeration

your comfort. our world. Ventilation Catalogue Heating Ventilation Integrated Solutions Air Conditioning Refrigeration your comfort. our world. Ventilation Catalogue Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Daikin Europe N.V. ABOUT DaiKIN Daikin has a worldwide reputation based on almost

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Ventilation. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Ventilation. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Ventilation All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration Daikin Europe N.V. ABOUT DAIKIN Daikin has a worldwide reputation based on almost 85 years experience

More information

Heat Recovery Ventilator

Heat Recovery Ventilator REKUPETORI Heat Recovery Ventilator Heat recovery ventilator Larger air supply rate enhanced heat exchange efficiency enhanced energy saving property The heat recovery ventilator (HRV) can reclaim heat

More information

Heat Reclaim Ventilation. VRV Air Handling Applications. a wide variety of daikin solutions. ventilation systems

Heat Reclaim Ventilation. VRV Air Handling Applications. a wide variety of daikin solutions.   ventilation systems Heat Reclaim Ventilation ventilation systems Outdoor Air Processing Unit VRV Air Handling Applications www.daikin.eu a wide variety of daikin solutions for the provision of fresh air and ventilation Daikin

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery Steven T. Taylor, PE Principal Taylor Engineering This program is registered with the AIA/CES for continuing professional education.

More information

Ventilation. Product catalogue 2019 for professionals

Ventilation. Product catalogue 2019 for professionals Ventilation Product catalogue 2019 for professionals Fresh air for the residential and commercial sector Heat reclaim ventilation and air handling applications Including new Modular L MODULAR L (SMART)

More information

SINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL

SINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL SINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL 3/4, 1, 1-1/2, and 2 Tons Mega Inverter Models: LS090HEV1 LS120HEV1 LS180HEV1 LS240HEV1 3/4 and 1 Tons Mega 115V Models: LS090HXV LS120HXV PROPRIETARY DATA

More information

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1

More information

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER Energy Recovery Ventilation Specialist Beijing Holtop Artificial Environment Technology Co., Ltd ISO 9001: 2000 Approved Company COMPANY BRIEF INTRODUCTION

More information

Adding More Fan Power Can Be a Good Thing

Adding More Fan Power Can Be a Good Thing This article was published in ASHE Journal, May 14. Copyright 14 ASHE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of

More information

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification

More information

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved. Monobloc LG Electronics Commercial Air Conditioning 56, Digital-ro 10-gil, Geumcheon-gu, Seoul, Korea www.lg.com http://partner.lge.com http://www.lgethermav.com Distributed by Copyright 2018 LG Electronics.

More information

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Buda, Texas 2a New Construction Construction

More information

Improving your home comfort by enhancing the air

Improving your home comfort by enhancing the air i n d o o r a i r q u a l i t y Improving your home comfort by enhancing the air The perfect answer to air quality problems? Healthy Climate Solutions. With fuel and electricity costs on the rise, today

More information

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h COMFORT ROOFTOP UNITS AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM 10000 TO 45000 m3/h climaveneta.com COMFORT ROOFTOP UNITS ENGINEERED FOR MAXIMUM EFFICIENCY AND VERSATILITY

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the

More information

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling PUT WASTE HEAT TO USE with our gas-heated steam humidifier, Humidification and evaporative cooling Cost-effective and eco-friendly steam production with gas as the primary energy source Touch Controller

More information

Ventilation Unit Zehnder ComfoAir 350

Ventilation Unit Zehnder ComfoAir 350 Use The ComfoAir 350 ventilation unit was developed for residential and small commercial buildings. It combines maximum comfort, simple operation and very high efficiency. The CA350 moves up to 218 cfm

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Alkis Triantafyllopoulos Mechanical Engineer Member TEE, MASHRAE a.trianta@gmail.com WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Based on ASHRAE 62 Purpose Set minimum Outdoor Air ventilation Rates Air Quality

More information

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL Single-Zone Ceiling-Concealed Ducted Heat Pump Systems 3/4 to 3 Tons Low Static LD097HV4 (9,000 Btu/h) LD127HV4 (12,000 Btu/h) High Static

More information

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying INDUSTRIAL DEHUMIDIFIERS Advanced range of compressor and desiccant dehumidifiers Dehumidification and drying To room From room Fan Regeneration heater Dry process air Regeneration air Regeneration area

More information

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: N-27661 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Heat Pumps M2 SERIES Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Water-source and geothermal heat pump self-contained units with capacities from 3-70 tons 10%-100% variable

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of5 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Modules Connected US Ton (nominal) Capacity (Btu/h) System Specifications

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

HRV Heat Reclaim Ventilation. FXMQ-MFV1 Outdoor Air Processing Unit. VRV+EXV-kit VRV Air Handling Applications

HRV Heat Reclaim Ventilation. FXMQ-MFV1 Outdoor Air Processing Unit. VRV+EXV-kit VRV Air Handling Applications Ventilation HRV Heat Reclaim Ventilation FXMQ-MFV1 Outdoor Air Processing Unit VRV+EXV-kit VRV Air Handling Applications c o n t e n t s p. 3 Table of Contents INTRODUCTION 4 HRV - HEAT RECLAIM VENTILATION

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

HVAC Mandatory Provisions Part II, Page 1

HVAC Mandatory Provisions Part II, Page 1 HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

Learn more about Samsung air conditioner at:

Learn more about Samsung air conditioner at: Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner 2015 SAMSUNG New Single Air-Conditioner SINGLE SINGLE is a smart choice for saving both money and energy.

More information

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Air Conditioning Domestic Heating Commercial Heating Photovoltaics Simple and Effective Fresh air from outside Excellent Air Quality and Unbeatable Heat Exchange Efficiency

More information