SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU
|
|
- Charleen Roberts
- 6 years ago
- Views:
Transcription
1 SINGLE Technical Data Book PAC for Europe (R4A, 5Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU
2 History Version Modification Date Remark Ver 1. Release SINGLE PAC for Europe (R4A, 5Hz)
3 Index 1 Nomenclature 2 Specifications 3 Capacity table 4 Dimensional drawing 5 Electrical wiring diagram 6 Sound pressure level 7 Sound power level 8 Temperature and air flow distribution 9 Cycle diagram Capacity correction
4 1 Nomenclature Indoor Units Model Names AC K N P D E H EU (1) (2) (3) (4) (5) (6) (7) (8) Buyer (1) Classification AC AM SINGLE VRF (5) Product Notation 1 1Way Cassette 2 2Way Cassette N 4Way Cassette S (6 x 6) 4 4Way Cassette S (2) Capacity x 1/ kw (3 digits) L M H LSP Duct (Slim Duct) MSP Duct HSP Duct C Ceiling (3) Version F 13 H 14 J 15 K 16 T P (6) Feature D F P Neo Forte PAC DELUXE FLAGSHIP Premium (4) Product Type G(EHS) Cascade (EEV) N Indoor Unit X Outdoor Unit (7) Rating Voltage C 1Ø, 8~2V, 6Hz E G K N 1Ø, 2~24V, 5Hz 3Ø, 38~415V, 5Hz 1Ø, 2~24V, 5/6Hz 3Ø, 38~415V, 5/6Hz (8) Mode C H D E Cooling Only(R4A) Heat Pump(R4A) Cooling Only(R22) Heat Pump(R22)
5 1 Nomenclature Outdoor Units Model Names AC K X A D E H EU (1) (2) (3) (4) (5) (6) (7) (8) Buyer (1) Classification (5) Feature1 AC SINGLE A Inv+Side+General Temp AM VRF B Non Inv+Side+General Temp (2) Capacity (6) Feature2 x 1/ kw (3 digits) D Deluxe F Flagship P Premium (3) Version F 13 S Standard H 14 J 15 K 16 (7) Rating Voltage E 1Ø, 2~24V, 5Hz G 3Ø, 38~415V, 5Hz K 1Ø, 2~24V, 5/6Hz N 3Ø, 38~415V, 5/6Hz (4) Product Type N Indoor Unit X Outdoor Unit (8) Mode C Cooling Only(R4A) H Heat Pump(R4A) D Cooling Only(R22) E Heat Pump(R22)
6 2 Specifications PAC Type Model Name System Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Mode - Capacity Power Energy Efficiency Piping Connections Cooling(Min/Std/Max) Heating(Min/Std/Max) Power Input (Nominal) Current Input (Nominal) MCA MFA Cooling(Min/Std/Max) Heating(Min/Std/Max) Cooling(Min/Std/Max) Heating(Min/Std/Max) kw Btu/h kw Btu/h EER (Nominal Cooling) - COP (Nominal Heating) - Energy Grade Liquid Pipe Gas Pipe Installation Max. Length Limitation Max. Height Power Source Wire Field Wiring Transmission Cable Refrigerant Power Supply Fan Drain Sound External Dimension Panel Size kw A A A - - Ø, mm Ø, inch Ø, mm Ø, inch m m Ø, mm Ø, mm Type - Control Method - Factory Charging kg Ø, #, V, Hz Type - Motor Output W Air Flow Rate External Static Pressure Min/Std/Max CMM l/s mmaq Pa Ø,mm db(a) kg kg mm mm - kg kg mm mm Drain Drain pump - Additional pump Accessories Max. Lifting mm/liter/h Air Filter - Power Supply Ø, #, V, Hz Type - Model - Compressor Output kw Fan Sound External Dimension Operating Temp. Range Oil Type - Air Flow Rate Pressure Power Net Weight Cooling Cooling/Heating Cooling Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) CMM l/s db(a) kg kg mm mm Cooling ºC Heating ºC * Specifications may be subject to change without prior notice. 1) Nominal cooling capacities are based on; - Indoor temperature : 27 C DB, 19 C WB - Outdoor temperature : 35 C DB, 24 C WB, Equivalent refrigerant piping : 5m, Level differences : m 2) Nominal heating capacities are based on; - Indoor temperature : C DB, 15 C WB SEER SCOP Turbo Drain Pipe Pressure Turbo/High/Med Power Net Weight Cooling Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel model Panel Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) - Outdoor temperature : 7 C DB, 6 C WB, Equivalent refrigerant piping : 5m, Level differences : m Floor Standing ACKNPDEH/EU ACKXADEH/EU Heat Pump 3.5 /. / ,9 / 34, / 42, 4. / 11. / , / 38, / 47,8 1. / 3.7 / / 3.39 / / 16.4 / / 14.9 /.5 Floor Standing AC14KNPDEH/EU AC14KXADGH/EU Heat Pump 4. / 13.4 / , / 45,7 / 57, 4. / 15.5 /. 13,6 / 52,9 / 68,.9 / 4.32 / / 4.5 / / 6.8 / / 6.7 / A+(5.8) - A+(4.1) /8" 3/8" /8" 5/8" 5 75 R4A EEV R4A EEV ,2,2-24,5 1,2,2-24,5 Sirocco Sirocco 97 x x / 44 / / 48 / x 1,85 x 4 6 x 1,85 x 4 75 x 1,963 x x 1,963 x 493 1,2,2-24,5 3,4,38-415,5 BLDC Rotary 3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. 4) These products contain R4A which is fluorinated greenhouse gas. Twin BLDC Rotary UG8TFUBJU UG5TK145FJX PVE PVE , , / / x 998 x 3 94 x 1,2 x x 1,96 x x 1,388 x ~ ~ ~ ~ 24.
7 3 Capacity table PAC ACKNPDEH/EU + ACKXADEH/EU Cooling Outdoor Air Temp. (DB) Indoor temperature (ºC) TC(Total Capacity), SHC(Sensible Heat Capacity), PI(Power Input) (DB) 22 (DB) 25 (DB) 27 (DB) 28 (DB) (DB) 32 (DB) 14 (WB) 16 (WB) 18 (WB) 19 (WB) (WB) 22 (WB) 24 (WB) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) Heating TC : Total Capacity, PI: Power Input Outdoor Air Temp. (DB) Indoor temperature (ºC) 16 (DB) 18 (DB) (DB) 21 (DB) 22 (DB) 24 (DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) AC14KNPDEH/EU + AC14KXADGH/EU Cooling Outdoor Air Temp. (DB) Indoor temperature (ºC) TC(Total Capacity), SHC(Sensible Heat Capacity), PI(Power Input) (DB) 22 (DB) 25 (DB) 27 (DB) 28 (DB) (DB) 32 (DB) 14 (WB) 16 (WB) 18 (WB) 19 (WB) (WB) 22 (WB) 24 (WB) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) TC(kW) SHC(kW) PI(kW) Heating TC : Total Capacity PI: Power Input Outdoor Air Temp. (DB) Indoor temperature (ºC) 16 (DB) 18 (DB) (DB) 21 (DB) 22 (DB) 24 (DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacities are based on following conditions;. Cooling mode indoor air temperature ( C, DB/WB) : /14, 22/16, 25/18, 27/19, 28/, /22, 32/24. Heating mode outdoor air : 85%RH. However, the condition rated capacity is 7 C DB / 6 C WB.. Refrigerant piping length : 5m. Level difference : m.
8 4 Dimensional drawing Indoor : PAC ACKNPDEH/EU, AC14KNPDEH/EU Units : mm / inches 6 [2'] 4 [1'-3 3/4"] 185 [6'- 3/4"] No. Name Description 1 Refrigerant gas pipe 2 Refrigerant liquid pipe 3 Drain pipe connection Ø15.88 Flare Ø9.52 Flare -
9 4 Dimensional drawing Outdoor ACKXADEH/EU Units : mm / inches 384 [1'-3 1/4"] 943 [3'-1 1/4"] 94 [3'-1"] 287 [11 1/4"] 491 [1'-7 1/4"] 688 [2'-3"] 983 [3'-2 3/4"] 655 [2'-1 3/4"] 998 [3'-3 1/4"] 3 [1'-1"] 621 [2'- 1/2"] Ø15.88 Ø 9.52 Ø.6 Ø 34.5 Ø 22.2
10 4 Dimensional drawing Outdoor AC14KXADGH/EU 5 Ø15.88 Ø 9.52 Ø.6 Ø 34.5 Ø 22.2
11 5 Electrical wiring diagram Indoor : PAC ACKNPDEH/EU, AC14KNPDEH/EU
12 5 Electrical wiring diagram Outdoor ACKXADEH/EU
13 5 Electrical wiring diagram Outdoor AC14KXADGH/EU
14 6 Sound pressure level Indoor : PAC Model Turbo Unit: db(a) Med ACKNPDEH/EU (ODU : ACKXADEH/EU) AC14KNPDEH/EU (ODU : AC14KXADGH/EU) Note * Specifications may be subject to change without prior notice 1) These operation values were obtained in an anechoic room. 2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed. 3) Operation sound level may differ depending on operation and ambient conditions. NC curve 1) ACKNPDEH/EU (ODU : ACKXADEH/EU) 2) AC14KNPDEH/EU (ODU : AC14KXADGH/EU) Turbo Med NC 6 NC 55 NC 5 NC Turbo Med NC 6 NC 55 NC 5 NC 45 Sound pressure level(db) NC 4 NC 35 NC NC 25 NC NC 15 Sound pressure level(db) NC 4 NC 35 NC NC 25 NC NC Octave band center frequency(hz) Octave band center frequency(hz)
15 6 Sound pressure level Outdoor Unit: db(a) Model Cooling Heating ACKXADEH/EU (IDU : ACKNPDEH/EU) AC14KXADGH/EU (IDU : AC14KNPDEH/EU) Note * Specifications may be subject to change without prior notice 1) These operation values were obtained in an anechoic room. 2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed. 3) Operation sound level may differ depending on operation and ambient conditions. NC curve 1) ACKXADEH/EU (IDU : ACKNPDEH/EU) 2) AC14KXADGH/EU (IDU : AC14KNPDEH/EU) Sound pressure level(db) Heating Cooling NC 65 NC 6 NC 55 NC 5 NC 45 NC 4 NC 35 NC NC 25 NC NC 15 Sound pressure level(db) Heating Cooling NC 65 NC 6 NC 55 NC 5 NC 45 NC 4 NC 35 NC NC 25 NC NC Octave band center frequency(hz) Octave band center frequency(hz)
16 7 Sound power level Indoor : PAC Note * Specifications may be subject to change 1) dba = A-weighted sound power level. 2) Reference power : 1pW. 3) Measured according to ISO Unit: db(a) Model Power ACKNPDEH/EU (ODU : ACKXADEH/EU) 6 AC14KNPDEH/EU (ODU : AC14KXADGH/EU) 63 1) ACKNPDEH/EU (ODU : ACKXADEH/EU) 8 2) AC14KNPDEH/EU (ODU : AC14KXADGH/EU) Sound power level(db) 5 4 Sound power level(db) A A Octave band center frequency(hz) Octave band center frequency(hz)
17 7 Sound power level Outdoor Note * Specifications may be subject to change 1) dba = A-weighted sound power level. 2) Reference power : 1pW. 3) Measured according to ISO Unit: db(a) Model Power ACKXADEH/EU (IDU : ACKNPDEH/EU) 7 AC14KXADGH/EU (IDU : AC14KNPDEH/EU) 7 1) ACKXADEH/EU (IDU : ACKNPDEH/EU) 8 2) AC14KXADGH/EU (IDU : AC14KNPDEH/EU) Sound power level(db) 5 4 Sound power level(db) A A Octave band center frequency(hz) Octave band center frequency(hz)
18 8 Temperature and air flow distribution Indoor : PAC ACKNPDEH/EU (1) Cooling air velocity distribution (2) Cooling temperature distribution (3) Heating air velocity distribution (4) Heating temperature distribution
19 8 Temperature and air flow distribution Indoor : PAC AC14KNPDEH/EU (1) Cooling air velocity distribution (2) Cooling temperature distribution (3) Heating air velocity distribution (4) Heating temperature distribution
20 9 Cycle diagram ACKNPDEH/EU + ACKXADEH/EU Category Symbol Description Compressor COMP Compressor Heat Exchanger HX_M HX_ID Heat Exchanger - Main (Outdoor unit) Heat Exchanger - Indoor unit Tank AC Accumulator Filter EEV Valve (etc) Thermistor Fan E_M SV_G SV_L T_CT T_D T_CO T_A T_IR T_II IFM OFM Filter Electronic Expansion Valve - Main Service Valve - Gas Pipe Service Valve - Liquid Pipe Thermistor - Compressor Top Thermistor - Discharge pipe Thermistor - Cond Out Thermistor - Ambient Thermistor - Indoor Room Thermistor - IDU Heat Exchanger In Indoor Fan Motor Outdoor Fan Motor
21 9 Cycle diagram AC14KNPDEH/EU + AC14KXADGH/EU Category Symbol Description Compressor COMP Compressor Heat Exchanger HX_M HX_ID Heat Exchanger - Main (Outdoor unit) Heat Exchanger - Indoor unit Tank AC Accumulator Filter EEV Valve (etc) Thermistor Fan E_M SV_G SV_L T_CT T_D T_CO T_A T_IR T_II OFM1 OFM2 IFM Filter Electronic Expansion Valve - Main Service Valve - Gas Pipe Service Valve - Liquid Pipe Thermistor - Compressor Top Thermistor - Discharge pipe Thermistor - Cond Out Thermistor - Ambient Thermistor - Indoor Room Thermistor - IDU Heat Exchanger In Outdoor Fan Motor 1 Outdoor Fan Motor 2 Indoor Fan Motor
22 Capacity correction Outdoor ACKNPDEH/EU + ACKXADEH/EU Cooling Level Difference (m) Pipe Length (m) Heating Level Difference (m) Pipe Length (m) AC14KNPDEH/EU + AC14KXADGH/EU Cooling Level Difference (m) Pipe Length (m) Heating Level Difference (m) Pipe Length (m)
23 16.7 Ver 1. Samsung Electronics Co., LTD. B2B PM / SE Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea Website : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.
SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)
SINGLE Technical Data Book SINGLE Duct S for America (R41A, HP) Model : AC MNHDCH/AA (Indoor unit) AC JXADCH/AA (Outdoor unit) History Version Modification Date Remark Ver.1. Release SINGLE Duct S for
More informationHistory List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)
History List Version Date Update Information 1.0 15.02.27-2015 New EHS SPLIT TDB Released. (Modify the Spec Note) 1.1 15.03.06 1.2 15.04.06 - Modify : Note(Spec, Capacity Table) / Electric Diagram / OD
More informationVRF Technical Data Book. Wind-Free 4Way Cassette for America (Low Ambient, R410A, HP)
VRF Technical Data Book Wind-Free 4Way Cassette for America (Low Ambient, R410A, HP) History Version Modification Date Remark Ver.1.0 Released CAC Wind-Free 4Way Cassette for North America (Low Ambient)
More informationPAC (FLOOR STANDING) 2016 Samsung
2016 Samsung PAC (FLOOR STANDING) SAMSUNG ELECTRONICS., LTD. Head Office : Suwon, Korea 416, Maetan-3Dong, Paldal-Gu, Suwon City Kyungki-Do, Korea 442-742 For more Information please visit www.samsung.com
More informationEHS. EHS (Mono, LT, 50Hz)
EHS EHS (Mono, LT, 50Hz) I. Products 1. Nomenclature.... 5 2. Line-up....... 7 1. Specification...... 9 2. Capacity Tables..... 13 3. Dimensional Drawings............. 19 4. Piping Diagrams..... 23 5.
More informationSAC Technical Data Book
SAC Technical Data Book Accessories Book for Global 1. MCU (Mode Control Unit) 2. EEV (Electronic Expansion Valve ) kit 3. AHU (Air Handling Unit) kit 4. FCU (Fan Coil Unit) Kit 5. UCK (Universal Communication
More informationLearn more about Samsung air conditioner at:
Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner 2015 SAMSUNG New Single Air-Conditioner SINGLE SINGLE is a smart choice for saving both money and energy.
More informationCHILLER Technical Data Book DVM CHILLER for Europe (R410A, 50/60Hz, HP)
CHILLER Technical Data Book DVM CHILLER for Europe (R41A, 5/6Hz, HP) Model : AG42/56/7KSV NH/EU History Version Modification Date Remark Ver.1. Release DVM Chiller(pump integrated) TDB for Europe 16. 5.
More informationSAMSUNG DVM Air Conditioner. Accessories. DVM PLUS III HP/HR North America for 60Hz
SAMSUNG DVM Air Conditioner Accessories DVM PLUS III HP/HR North America for 60Hz Accessories I. Panels & Drain pumps 1 2 Panels Drain pumps 6 7 II. Branch joints 1 2 3 4 5 Y-joints Y-joints (HR only)
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationAir-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)
Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.
More informationSINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL
SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL Single-Zone Ceiling-Concealed Ducted Heat Pump Systems 3/4 to 3 Tons Low Static LD097HV4 (9,000 Btu/h) LD127HV4 (12,000 Btu/h) High Static
More informationAir-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)
Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.
More informationLG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.
2016 2016 LG HVAC SOLUTION LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2016 LG Electronics. All rights reserved. LG SOLUTION 01 LG s MULTI V IV Development Philosophy
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationSamsung Air Conditioning
Samsung Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and grow in
More informationCold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply
Cold Remedies. Meet the Max Heat family. The ideal solutions for the harshest of colds. Our Max Heat units provide high heating capacity at -13 F to keep you comfortable. Look inside for our complete line
More informationCASSETTE TYPE AIR CONDITIONER
CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....
More informationSamsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING. Samsung Air Conditioning 1
Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING Samsung Air Conditioning 1 2 Samsung Air Conditioning Contents 4 Stylish 4Way Cassette S 6 Enhanced and Powerful 4Way Mini Cassette 7 Innovative
More information1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units
Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply
More informationA single answer for multiple zones.
Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available
More informationLG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.
LG AIR CONDITIONERS Ducted Split System Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...
More informationSamsung Free Joint Multi Air Conditioning System
Samsung Free Joint Multi Air Conditioning System Air Conditioning solutions from a brand you can rely on At the heart of family living is the home, a place full of special moments and wonderful memories
More informationAir Conditioners. Technical Data RZQG-L
Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t
More informationCompact 4-way Cassette ( ) Type
E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference
More informationLG AIR CONDITIONERS Ducted Split System. Clean, Quiet & Comfortable with LG HVAC.
LG AIR CONDITIONERS Ducted Split System Clean, Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive
More informationA single answer for multiple zones.
FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationSingle Zone Air Conditioner SVC MANUAL (Exploded View)
Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10
More information(Non-Inverter & Inverter) R410A
LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter
More informationmini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS
mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity
More informationHeat Pump Air Conditioning Systems
Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.
More informationEEDEN technical data ERHQ AA
EEDEN08-70 technical data Altherma Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil
More informationSamsung EHS, XL Range of Commercial Air to water heat pumps
Samsung EHS, XL Range of Commercial Air to water heat pumps 2018 Freedom Heat Pumps Spec and price Guide Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered
More informationVARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG
VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1
More informationSingle-Zone Four-Way Ceiling-Cassette System Engineering Manual
Single-Zone Four-Way Ceiling-Cassette System Engineering Manual Single-Zone Four-Way Ceiling Cassette Heat Pump Systems 1.5 to 3.5 Tons LC187HV (18,000 Btu/h) LC247HV (24,000 Btu/h) LC367HV (36,000 Btu/h)
More informationLG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)
Internal Use Only http://biz.lgservice.com LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) MODEL : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationIntegrated VarIable refrigerant flow ahu/pau (r410a)
Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02
More informationSINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL
SINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL 3/4, 1, 1-1/2, and 2 Tons Mega Inverter Models: LS090HEV1 LS120HEV1 LS180HEV1 LS240HEV1 3/4 and 1 Tons Mega 115V Models: LS090HXV LS120HXV PROPRIETARY DATA
More informationWell rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.
360 CASSETTE Well rounded. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. Product Registration Required Conditions Apply 2017 Samsung HVAC 63714_SAMSUN_360_Cassette_v13.indd
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationAir Conditioning Technical Data RZAG-MV1
Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More informationELECTRICAL QUANTITY WEIGHT (LB)
VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /
More informationEngineering Data Manual
Engineering Data Manual Residential Split Low Silhuoette LSN DCI Inverter Series Indoor Units LSN 25 DCI LSN 35 DCI LSN 50 DCI LSN 60 DCI LSN 72 DCI Outdoor Units ONG 25 DCI ONG 35 DCI ONG 50 DCI GC 60
More information(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)
(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) (60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) CONTENTS Part 1 General information Part 2 Product data Part 3 Design and installation Part 4 Special parts 2 Introduction
More informationVRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular
MI NG Your Modern Green Idea NI SP L IT S VRF ED PTAC SOLAR L LIG HT I Solar Series Mini & Modular VRF Outdoor Units Ultra Heating Mini & Modular Heat Recovery Modular FEATURES & SPECIFICATIONS YMGI Group
More informationEngineering Data Book
40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationLG AIR CONDITIONERS 2013 Ducted Split System
Australia Pty Ltd. NEW SOUTH WALES / HEAD OFFICE 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 AUS-DU113 QUEENSLAND 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000
More informationSingle zone HIGH Efficiency
Single zone HIGH Efficiency WALL MOUNT Engineering Manual 3/4, 1, and 1-1/2 Tons Models: LS090HSV4 LS120HSV4 LS180HSV4 Proprietary Data Notice This document, as well as all reports, illustrations, data,
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationtechnical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air
technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help
More informationMiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL
MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors
More informationLSN DC Inverter Series
LSN DC Inverter Series Indoor Units Outdoor Units LSN 25 DCI ONG3-25 DCI LSN 35 DCI ONG3-35 DCI LSN 50 DCI DCI 50 LSN 60 DCI DCI 60 LSN 72 DCI DCI 72Z REFRIGERANT R410A HEAT PUMP AUGUST 2008 LIST OF EFFECTIVE
More informationAir Cooled Packaged Systems AIRAH Back to Basics
Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability
More informationtechnical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air
technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More information6. DUCT TYPE AR 60FUAK, AR 60UUAK
R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor
More informationLG VRF Systems. Air Conditioning Technologies
LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationSamsung 360 Cassette, Single Zone, Split System
Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal
More informationGOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING. VRF SPECIFIERS DESIGN GUIDE 4 th EDITION
GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING VRF SPECIFIERS DESIGN GUIDE 4 th EDITION 1 www.samsung.com/uk/dvms Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered
More information[U] Serie MHB / MHA Manual de Ingeniería
[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance
More information1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5
M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W183CSA5 AS-W243CSA5 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual.
More informationEngineering Data Book
40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationInnovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date
Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser
More informationService Manual. Compact Series REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12
Service Manual Compact Series Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12 REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP SEPTEMBER - 2005 LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.
More informationEngineering Data Book
40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationWith LG HVAC, It's all Possible
Australia Pty Ltd. NEW SOUTH WALES / HEAD OFFICE 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 AUS-DU1311 QUEENSLAND 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationSubmittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationEngineering Data Book
40VMU Under Ceiling/Floor Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationDUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON
* H E A T I N G & C O O L I N G DUCTED SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. Mobile device not included * Terms and Conditions apply. See back cover for details.
More informationEngineering Data Book
40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationTechnical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP
Technical Manual Multi Split Trio Quattro DCI Indoor Units WNG 9 DCI INV WNG 12 DCI INV WNG 18 DCI INV ECF 9 DCI INV ECF 12 DCI INV ECF 18 DCI INV PXD 9 DCI INV PXD 12 DCI INV PXD 18 DCI INV LS 35 DCI
More informationSubmittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System
Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote
More information4-Way Cassette type. Contents MMU-AP 2H2UL
E15-3C1 6 Indoor unit MMU-AP 2H2UL 4-Way Cassette type MMU-AP0072H2UL MMU-AP0092H2UL MMU-AP0122H2UL MMU-AP0152H2UL MMU-AP0182H2UL MMU-AP0212H2UL MMU-AP0242H2UL MMU-AP0302H2UL MMU-AP0362H2UL MMU-AP0422H2UL
More informationSubmittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationPHD3. Product Specifications
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationFUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION
FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationBENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
1.5-Ton Wall Mounted Unit FAQ18PVJURZQ18PVJU9 FEATURES Maximum piping length up to 164 ft. allows flexible placement of indoor unit Maximum piping height separation up to 98 ft. Low ambient cooling operation
More informationPAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More information15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return
More informationDuctless Split Systems Concealed Duct Heat Pumps
Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH
More informationSubmittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationAIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK
AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...
More informationDUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.
DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01
More informationSubmittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More information