SAMSUNG DVM Air Conditioner. Accessories. DVM PLUS III HP/HR North America for 60Hz

Size: px
Start display at page:

Download "SAMSUNG DVM Air Conditioner. Accessories. DVM PLUS III HP/HR North America for 60Hz"

Transcription

1 SAMSUNG DVM Air Conditioner Accessories DVM PLUS III HP/HR North America for 60Hz

2

3 Accessories

4 I. Panels & Drain pumps 1 2 Panels Drain pumps 6 7 II. Branch joints Y-joints Y-joints (HR only) Header joints Outdoor joints Outdoor joints (HR only)

5 III. EEV kits Models Cycle function parts Dimensional drawing PCB connector lay-out Electrical wiring diagram IV. MCU kits Models Cycle function parts Dimensional drawing PCB connector lay-out Electrical wiring diagram Panels & Drain pumps Branch joints EEV kits MCU kits 3

6 DVM PLUS III 4

7 I. Panels & Drain pumps 1 Panels Drain pumps...7 Panels & Drain pumps 5

8 1 Panels 1-1. Models Model name PSSMA P4SMA PMSMA Slim 1 way cassette panel 4 way cassette panel Mini 4 way cassette panel Description 1-2. Dimensional drawing PSSMA Unit: mm(inch) 1180(46-1/2) 863(34) 25(1) 197(7-3/4) 94(3-3/4) 460(18-1/8) 861(33-7/8) P4SMA PMSMA 950(37-1/2) 541(21-1/4) 30(1-3/16) 621(24-1/2) 950(37-3/8) 96(3-3/4) 428(16-3/4) 61(2-3/8) 670(26-1/2) 343(13-1/2) 28(1-1/8) 670(26-1/2) 6

9 2 Drain pumps 2-1. Models Model name MDP-E075SEE MDP-E075SEE1 MDP-E075SEE3 MDP-M075SGU1 MDP-M075SGU2 Description AVXDSH020/032/040/052/072CE models (Slim duct 6.0 ~ 24.0 MBH) AVXDSH100/110/145CE models (Slim duct 30.0 ~ 48.0 MBH) AVXDSH020/032/040/052/072/100/110/145CE 01 models (Slim duct 6.0 ~ 48.0 MBH) AVXDUH100/110CE models (MSP duct 30.0 ~ 36.0 MBH) AVXDUH145CE model (MSP duct 48.0 MBH) Panels & Drain pumps 7

10 DVM PLUS III 8

11 II. Branch joints 1 Y-joints Y-joints (HR only) Header joints Outdoor joints Outdoor joints (HR only)...15 Branch joints 9

12 1 Y-joints 1-1. Models Model name MXJ-YA1509 MXJ-YA2512 MXJ-YA2812 MXJ-YA2815 MXJ-YA3119 MXJ-YA3819 Total indoor unit s capacities 51.0 MBH and below Over 51.0~138.0 MBH and below Over ~160.0 MBH and below Over ~ MBH and below Over ~ MBH and below Over ~ MBH and below 1-2. Dimensional drawing Y-joint for indoor unit MXJ-YA1509 Liquid Gas 1 x 2 EA 2 x 2 EA MXJ-YA2512 Liquid Gas 1 x 2 EA 3 x 2 EA MXJ-YA2812 Liquid Gas 1 x 2 EA 3 7 x 1 EA, x 1 EA MXJ-YA2815 Liquid Gas 2 x 2 EA 3 7 x 1 EA, x 1 EA 10

13 MXJ-YA3119 Liquid Y-joint for indoor unit Gas MXJ-YA3819 Liquid 3 x 1 EA 2 x 2 EA 4 x 1 EA Gas Branch joints 3 x 1 EA 4 x 1 EA 2 x 2 EA 5 x 1 EA Reducer

14 2 Y-joints (HR only) 2-1. Models Model name MXJ-YA1500 MXJ-YA2500 MXJ-YA3100 Total indoor unit s capacities 80 MBH and below Over 80~240 MBH and below Over 240~468 MBH and below 2-2. Dimensional drawing Y-joint for HR (High pressure gas) MXJ-YA1500 High pressure gas MXJ-YA2500 High pressure gas 1 x 2 EA MXJ-YA3100 High pressure gas 1 2 x 1 EA x 1 EA Reducer

15 3 Header joints 3-1.Models Model name Total indoor unit s capacities The maximum quantity of connection MXJ-HA MBH and below 4 MXJ-HA3115 Over ~ MBH 8 MXJ-HA3819 Over MBH Dimensional drawing MXJ-HA2512 Liquid Header joint Gas Branch joints 1 x 4 EA 2 x 1 EA 3 x 4 EA 7 a x 1 EA 5 x 1 EA MXJ-HA3115 Liquid Gas 1 x 8 EA 4 x 1 EA 3 x 8 EA 7 b x 1 EA 6 x 1 EA MXJ-HA3819 Liquid Gas 1 x 8 EA 7 c x 1 EA 3 x 8 EA Reducer a b c 13

16 4 Outdoor joints 4-1. Models Model name MXJ-T3819 Below 30 Ton Total indoor unit s capacities 4-2. Dimensional drawing MXJ-T3819 Liquid Outdoor joint Gas 2 x 1 EA 1 x 2 EA 3 x 2 EA Reducer

17 5 Outdoor joints (HR only) 5-1. Models Model name MXJ-T ~30 TON Total indoor unit s capacities 5-2. Dimensional drawing Outdoor joint MXJ-T3100 High pressure gas Branch joints x 1 EA x 1 EA x 1 EA Reducer

18 DVM PLUS III 16

19 III. EEV kits 1 Models Cycle function parts Dimensional drawing PCB connector lay-out Electrical wiring diagram...24 EEV kits 17

20 1 Models 1-1. Singel EEV kits Model Connectable capacity of indoor units Quantity of connectable indoor units MEV-A13SA Up to 12.0 MBH units 1 MEV-A16SA 18.0 ~ 24.0 MBH units 1 Description Weight (Net) Indoor units Remarks 1kg(2.2 lbs) Wall mounted units Ceiling units Extension wire included 1-2. Two rooms EEV kits Model MXD-A13K116A Connectable capacity of indoor units Quantity of connectable indoor units Up to 12.0 MBH units ~ 24.0 MBH units 1 MXD-A13K200A Up to 12.0 MBH units 2 MXD-A16K200A 18.0 ~ 24.0 MBH units 2 MXD-A22K200A Over 24.0 MBH units 2 Description Weight (Net) Indoor units Remarks 7.3kg(16 lbs) Wall mounted units Ceiling units Three rooms EEV kits Model MXD-A13K216A Connectable capacity of indoor units Quantity of connectable indoor units up to 12.0 MBH units ~ 24.0 MBH units 1 MXD-A13K300A Up to 12.0 MBH units 3 MXD-A16K213A Up to 12.0 MBH units ~ 24.0 MBH units 2 MXD-A16K300A 18.0 ~ 24.0 MBH units 3 Description Weight (Net) Indoor units Remarks 7.6kg(16.8 lbs) Wall mounted units Ceiling units - 18

21 2 Cycle function parts 2-1. Single EEV kits EEV EEV connector IN OUT Liquid pipe connection to indoor unit Liquid pipe connection from outdoor unit 2-2. Two rooms EEV kits Liquid pipe connection Gas pipe connection EEVs EEV kits Indoor unit (wall mounted) Liquid pipe connection Outdoor unit Gas pipe connection 2-3 Three rooms EEV kits Liquid pipe connection Gas pipe connection EEVs Indoor unit (wall mounted) Liquid pipe connection Outdoor unit Gas pipe connection 19

22 3 Dimensional drawing 3-1. Single EEV kits Unit: mm(inch) 86(3-3/8) 72(2-7/8) 201(7-7/8) 169(6-5/8) 48(1-7/8) 118(4-5/8) No. Name 1 Liquid pipe connection from branch joint [Ø6.35(1/4"), Flare] 2 Liquid pipe connection to wall mounted/ceiling unit [Ø6.35(1/4"), Flare] 20

23 3-2. Two rooms EEV kits Unit: mm(inch) 105(4-1/8) 300(11-3/4) Service area for piping work 450(17-3/4) 360(14-1/8) Service area for PCB 120(4-3/4) 190(7-1/2) EEV kits 333(13-1/8) 323(12-3/4) 500(19-5/8) 458(18) 202(7-15/16) 40(1-5/8) 85(3-3/8) 40(1-5/8) 204(8-1/16) 40(1-5/8) 39(1-4/8) 44(1-3/4) 20(3/4) 403(15-7/8) 110(4-3/8) 130(5-1/8) 56(2-1/4) 97(3-7/8) No. Name 1 Liquid pipe connection from branch joint 2 Gas pipe connection from branch joint 3 Liquid pipe connections to wall mounted/ceiling units 4 Gas pipe connections to wall mounted/ceiling units Condensate drain pipe connection 5 [ID 12.5/OD17.5(ID 1/2" /OD 11/16")] 6 PCB in EEV kits 7 Power and communication wiring terminal blocks from outdoor unit 8 Power and communication wiring terminal blocks to indoor units Model MXD- A13K116A Pipe size [Ø, mm(inch)] MXD- A13K200A MXD- A16K200A MXD- A22K200A No (3/8") 9.52(3/8") 9.52(3/8") 9.52(3/8") (5/8") 15.88(5/8") 15.88(5/8") 19.05(3/4") (1/4") 6.35(1/4") 9.52(3/8") 9.52(3/8") 9.52(3/8") 6.35(1/4") 9.52(3/8") 9.52(3/8") 12.70(1/2") 12.70(1/2") 15.88(5/8") 15.88(5/8") 15.88(5/8") 12.70(1/2") 15.88(5/8") 15.88(5/8") 21

24 3 Dimensional drawing 3-3. Three rooms EEV kits Unit: mm(inch) 105(4-1/8) 300(11-3/4) Service area for piping work 450(17-3/4) 360(14-1/8) Service area for PCB 120(4-3/4) 190(7-1/2) 333(13-1/8) 500(19-5/8) 323(12-3/4) 313(12-3/8) 202(7-15/16) 40(1-5/8) 85(3-3/8) 40(1-5/8) 204(8-1/16) 40(1-5/8) 39(1-4/8) 40(1-5/8) 20(3/4) 458(18) 403(15-7/8) 110(4-3/8) 130(5-1/8) 56(2-1/4) 97(3-7/8) 44(1-3/4) No. Name 1 Liquid pipe connection from branch joint 2 Gas pipe connection from branch joint 3 Liquid pipe connections to wall mounted/ceiling units 4 Gas pipe connections to wall mounted/ceiling units 5 Condensate drain pipe connection [ID 12.5/OD17.5(ID 1/2" /OD 11/16")] 6 PCB in EEV kits 7 Power and communication wiring terminal blocks from outdoor unit 8 Power and communication wiring terminal blocks to indoor units Model No. MXD- A13K216A Pipe size [Ø, mm(inch)] MXD- A13K300A MXD- A16K213A MXD- A16K300A (3/8") 9.52(3/8") 9.52(3/8") 9.52(3/8") (5/8") 15.88(5/8") 15.88(5/8") 19.05(3/4") (1/4") 6.35(1/4") 9.52(3/8") 9.52(3/8") 9.52(3/8") 6.35(1/4") 9.52(3/8") 9.52(3/8") 9.52(3/8") 6.35(1/4") 9.52(3/8") 9.52(3/8") 12.70(1/2") 12.70(1/2") 15.88(5/8") 15.88(5/8") 12.70(1/2") 12.70(1/2") 15.88(5/8") 15.88(5/8") 15.88(5/8") 12.70(1/2") 12.70(1/2") 15.88(5/8") 22

25 4 PCB connector lay-out No. CN # COLOR FUNCTION 1 CN31 Red Communication with Outdoor Unit 2 CN71 Blue AC 208~230V Input 2 CN61 Yellow EEV A No. CN # COLOR FUNCTION 4 CN62 Blue EEV B 5 CN63 White EEV C 6 CN91 White MICOM Download EEV kits 23

26 5 Electrical wiring diagram

27 IV. MCU kits 1 Models Cycle function parts Dimensional drawing PCB connector lay-out Electrical wiring diagram...33 MCU kits 25

28 1 Models Model Description Quantity of connectable indoor units Weight (Net) Total capacity EEV MCU-X4NEF1 Up to 4 units 24kg MCU-X6NEF1 Up to 6 units 27kg Below 152MBH Extension wire included Model MCU-X4VEF1 MCU-X4WEF1 Description Quantity of connectable indoor units Weight (Net) Total capacity EEV Up to 4 units 26kg Below 152MBH (12MBH indoor units) Below 152MBH (18MBH indoor units) Included 26

29 2 Cycle function parts 2-1. MCU-X4NEF1 Heating solenoid valve Cooling solenoid valve MCU liquid bypass valve Gas pipe connection (Outdoor unit) High pressure gas pipe connection (Outdoor unit) Drain pipe Liquid pipe connection (Outdoor unit) Outdoor unit Liquid pipe connection (Indoor unit) Gas pipe connection (Indoor unit) Indoor unit Subcooler EEV MCU EEV MCU main heating valve 2-2. MCU-X6NEF1 Heating solenoid valve Cooling solenoid valve MCU liquid bypass valve Gas pipe connection (Outdoor unit) MCU joints High pressure gas pipe connection (Outdoor unit) Drain pipe Liquid pipe connection (Outdoor unit) Outdoor unit Liquid pipe connection (Indoor unit) Gas pipe connection (Indoor unit) Indoor unit Subcooler EEV MCU EEV MCU main heating valve 27

30 2 Cycle function parts 2-3. MCU-X4VEF1/MCU-X4WEF1 Heating solenoid valve Cooling solenoid valve MCU liquid bypass valve Gas pipe connection (Outdoor unit) High pressure gas pipe connection (Outdoor unit) EEV Drain pipe Liquid pipe connection (Outdoor unit) Outdoor unit EEV bypass valve Liquid pipe connection (Indoor unit) Gas pipe connection (Indoor unit) Indoor unit Subcooler EEV MCU EEV MCU main heating valve No Cycle parts Functions 1 Heating solenoid valve This valve opens during heating and main heating operation. 2 Cooling solenoid valve This valve opens during cooling and main cooling operation. 3 MCU liquid bypass valve This valve is used to prevent pipe from refrigerant accumulation in main heating operation. 4 MCU EEV It controls refrigerant amount to balance between outdoor heat exchanger and indoor heat exchanger in main heating operation. 5 Subcooler The subcooler can secure the subcooling of refrigerant in MCU. 6 Subcooler_in temp.sensor These temperature sensors enable to control subcooler EEV s step to secure 7 Subcooler_out temp.sensor subcooling of refrigerant. 8 Subcooler EEV It enables to secure sufficient subcooling of entering refrigerant to MCU kit. 9 EEV This EEV can be used for wall mounted / ceiling unit. 10 EEV bypass valve This valve has to be closed when wall mounted / ceiling unit are connected without single EEV kit. 28

31 3 Dimensional drawing 3-1. MCU-X4NEF1 Unit: mm MCU joints No. Name 1 Liquid pipe connection from outdoor unit (Ø12.70, Flare) 2 High pressure gas pipe connection from outdoor unit (Ø19.05, Brazing) 3 Gas pipe connection from outdoor unit (Ø28.58, Flange) 4 Liquid pipe connection to indoor units 5 Gas pipe connection to indoor units 6 Condensate drain pipe connection (ID 22.5/OD 26.5) 7 Power and communication wiring conduits 8 Power wiring terminal blocks for indoor units 9 Communication wiring terminal blocks for indoor units 10 PCB of MCU 29

32 3 Dimensional drawing 3-2. MCU-X6NEF1 Unit: mm No. Name 1 Liquid pipe connection from outdoor unit (Ø12.70, Flare) 2 High pressure gas pipe connection from outdoor unit (Ø19.05, Brazing) 3 Gas pipe connection from outdoor unit (Ø28.58, Flange) 4 Liquid pipe connection to indoor units 5 Gas pipe connection to indoor units 6 Condensate drain pipe connection (ID 22.5/OD 26.5) 7 Power and communication wiring conduits 8 Power wiring terminal blocks for indoor units 9 Communication wiring terminal blocks for indoor units 10 PCB of MCU 30

33 3-3. MCU-X4VEF1/MCU-X4WEF1 Unit: mm MCU joints No. Name 1 Liquid pipe connection from outdoor unit (Ø12.70, Flare) 2 High pressure gas pipe connection from outdoor unit (Ø19.05, Brazing) 3 Gas pipe connection from outdoor unit (Ø28.58, Flange) 4 Liquid pipe connection to indoor units 5 Gas pipe connection to indoor units 6 EEV Bypass valve 7 Condensate drain pipe connection (ID 22.5/OD 26.5) 8 Power and communication wiring conduits 9 Power wiring terminal blocks for indoor units 10 Communication wiring terminal blocks for indoor units 11 PCB of MCU 31

34 4 PCB connector lay-out No. CN # COLOR FUNCTION 1 CN71 Blue AC 230V Input 2 CN72 Yellow Port A/B Cooling/Heating Solenoid Valve 3 CN73 White Port C/D Cooling/Heating Solenoid Valve 4 CN74 Blue Port E/F Cooling/Heating Solenoid Valve 5 CN75 Red Main Heating Valve, Liquid Bypass Valve 6 CN31 Red Communication with Indoor Units (COM1) 7 CN10 ±Sub Black Sub MICOM Download 8 CN10 Black Main MICOM Download No. CN # COLOR FUNCTION 9 CN62 Blue Main EEV 10 CN63 White EEV1 11 CN84 Black EEV2 12 CN85 Red EEV3 13 CN66 Blue EEV4 14 CN67 Yellow Subcooler EEV 15 CN50 Yellow Subcooler-In Sensor 16 CN49 White Subcooler-Out Sensor 32

35 5 Electrical wiring diagram HIGH PRESSURE SENSOR MCU joints 1 6 AC 230V AC 230V AC 230V AC 230V 33

36

37 DVM Technical Data Book DVM

38 Accessories Samsung Electronics Co., LTD. Digital Air Solution Division, Sales & Marketing Team, SE Dept Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea TEL : Website : airconditioner@samsung.com Specification may be subject to change without prior notice for the continuous product improvement DB A(3)

SAC Technical Data Book

SAC Technical Data Book SAC Technical Data Book Accessories Book for Global 1. MCU (Mode Control Unit) 2. EEV (Electronic Expansion Valve ) kit 3. AHU (Air Handling Unit) kit 4. FCU (Fan Coil Unit) Kit 5. UCK (Universal Communication

More information

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU SINGLE Technical Data Book PAC for Europe (R4A, 5Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU History Version Modification Date Remark Ver 1. Release SINGLE PAC for Europe (R4A, 5Hz) 16.7.15 - Index 1

More information

2008 SAMSUNG SYSTEM AIR CONDITIONERS Version.2

2008 SAMSUNG SYSTEM AIR CONDITIONERS Version.2 2008 SAMSUNG SYSTEM AIR CONDITIONERS Version.2 imagine imagine imagine natural coolness 2008 Samsung Ceiling Air Conditioners will give you the coolness that you have been waiting for. With this year's

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of5 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Modules Connected US Ton (nominal) Capacity (Btu/h) System Specifications

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Power Indoor Units Modules Connected US Ton (nominal) Capacity

More information

Your Home. Jacco & Assoc.

Your Home. Jacco & Assoc. Your Home Fan on with call for heating or cooling Heating on with call from space thermostat Stage as required to maintain 75F adj. First stage The of heating Installation shall be heat of pump VRF Cooling

More information

INSTALLATION MANUAL DVM PLUS III RVXVHT G Series RVXVRT G Series

INSTALLATION MANUAL DVM PLUS III RVXVHT G Series RVXVRT G Series INSTALLATION MANUAL DVM PLUS III RVXVHT G Series RVXVRT G Series System Air Conditioner (Cooling and Heating) E DB98-29412A(2) safety information SAFETY INFORMATION Before installing an air conditioner,

More information

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Wall Mounted Air Conditioner SVC MANUAL(Exploded View) MODEL : AMNW07GDBL1 [LMN077HVT] AMNW09GDBL1 [LMN097HVT] AMNW12GDBL1 [LMN127HVT] AMNW15GDBL1 [LMN157HVT]

More information

GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING. VRF SPECIFIERS DESIGN GUIDE 4 th EDITION

GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING. VRF SPECIFIERS DESIGN GUIDE 4 th EDITION GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING VRF SPECIFIERS DESIGN GUIDE 4 th EDITION 1 www.samsung.com/uk/dvms Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

EHS. EHS (Mono, LT, 50Hz)

EHS. EHS (Mono, LT, 50Hz) EHS EHS (Mono, LT, 50Hz) I. Products 1. Nomenclature.... 5 2. Line-up....... 7 1. Specification...... 9 2. Capacity Tables..... 13 3. Dimensional Drawings............. 19 4. Piping Diagrams..... 23 5.

More information

PAC (FLOOR STANDING) 2016 Samsung

PAC (FLOOR STANDING) 2016 Samsung 2016 Samsung PAC (FLOOR STANDING) SAMSUNG ELECTRONICS., LTD. Head Office : Suwon, Korea 416, Maetan-3Dong, Paldal-Gu, Suwon City Kyungki-Do, Korea 442-742 For more Information please visit www.samsung.com

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

Air Conditioner. installation manual. imagine the possibilities. DVM S WATER-GEO AM KXWD Series AM HXWA Series AM KXWA Series

Air Conditioner. installation manual. imagine the possibilities. DVM S WATER-GEO AM KXWD Series AM HXWA Series AM KXWA Series DVM S WATER-GEO AM KXWD Series AM HXWA Series AM KXWA Series Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product. Contents Before Installation Safety

More information

Air Conditioner. installation manual. imagine the possibilities

Air Conditioner. installation manual. imagine the possibilities DVM S AM FXVAF Series AM FXVAJ Series AM HXVAF Series AM HXVAJ Series AM KXVTF Series AM KXVTJ Series AM KXVGJ Series Air Conditioner installation manual imagine the possibilities Thank you for purchasing

More information

Air Conditioner. installation manual. imagine the possibilities. DVM S WATER-GEO AM HXWA Series EN ES FR PT DB A-00

Air Conditioner. installation manual. imagine the possibilities. DVM S WATER-GEO AM HXWA Series EN ES FR PT DB A-00 DVM S WATER-GEO AM HXWA Series Air Conditioner installation manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. EN ES FR PT DB68-04799A-00

More information

DVM S Universal Communication Kit (UCK) Design Guide

DVM S Universal Communication Kit (UCK) Design Guide DVM S Universal Communication Kit (UCK) Design Guide MCM-D211UN MXD-A24K100E MXD-A32K100E MXD-A40K100E MXD-A64K100E Version 11192018 Definition of Universal Communication Kit Technical Specification AHU

More information

Samsung Free Joint Multi Air Conditioning System

Samsung Free Joint Multi Air Conditioning System Samsung Free Joint Multi Air Conditioning System Air Conditioning solutions from a brand you can rely on At the heart of family living is the home, a place full of special moments and wonderful memories

More information

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT SERVICE Manual SYSTEM AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Set Up the

More information

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View) MDEL : ARNH10GK2A2 / ARNH04GK2A2 CAUTIN Before Servicing the unit, read the safety precautions in

More information

Only properly trained, HVAC professionals should attempt to install and start up any Samsung heating and airconditioning

Only properly trained, HVAC professionals should attempt to install and start up any Samsung heating and airconditioning DVM S Eco Training Rev 3.4 DVM S Eco Training Due to Samsung s policy of ongoing product development, specifications are subject to change without prior notice. Every effort has been made to insure that

More information

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP) SINGLE Technical Data Book SINGLE Duct S for America (R41A, HP) Model : AC MNHDCH/AA (Indoor unit) AC JXADCH/AA (Outdoor unit) History Version Modification Date Remark Ver.1. Release SINGLE Duct S for

More information

MCU. installation manual. imagine the possibilities DB A-06 EN ZH MCU-S6NEE1N MCU-S4NEE1N MCU-S4NEE2N MCU-S2NEK1N

MCU. installation manual. imagine the possibilities DB A-06 EN ZH MCU-S6NEE1N MCU-S4NEE1N MCU-S4NEE2N MCU-S2NEK1N -S6NEE1N -S4NEE1N -S4NEE2N -S2NEK1N installation manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. EN ZH DB68-03490A-06 Contents

More information

VRF Technical Data Book. Wind-Free 4Way Cassette for America (Low Ambient, R410A, HP)

VRF Technical Data Book. Wind-Free 4Way Cassette for America (Low Ambient, R410A, HP) VRF Technical Data Book Wind-Free 4Way Cassette for America (Low Ambient, R410A, HP) History Version Modification Date Remark Ver.1.0 Released CAC Wind-Free 4Way Cassette for North America (Low Ambient)

More information

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Block Diagrams

More information

Main Feature. Silent Mode Indoor units operate quietly with the least possible noise.

Main Feature. Silent Mode Indoor units operate quietly with the least possible noise. Main Feature Floor & Convertible type Indoor Units Installation options can t be more diverse than Samsung s floor and convertible type air conditioner. With a variety of installation options and the elegant

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. 360 CASSETTE Well rounded. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. Product Registration Required Conditions Apply 2017 Samsung HVAC 63714_SAMSUN_360_Cassette_v13.indd

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING. Samsung Air Conditioning 1

Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING. Samsung Air Conditioning 1 Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING Samsung Air Conditioning 1 2 Samsung Air Conditioning Contents 4 Stylish 4Way Cassette S 6 Enhanced and Powerful 4Way Mini Cassette 7 Innovative

More information

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS. SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM

More information

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) Internal Use Only http://biz.lgservice.com LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) MODEL : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L

More information

Engineering Data Book

Engineering Data Book E13-3O1 Heat recovery Model name: MMY-MAP_4FT9UL (208/230 V, 60 Hz) MMY-MAP_4FT6UL (460 V, 60 Hz) Heat pump Model name: MMY-MAP_4HT9UL (208/230 V, 60 Hz) MMY-MAP_4HT6UL (460 V, 60 Hz) Engineering Data

More information

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply Cold Remedies. Meet the Max Heat family. The ideal solutions for the harshest of colds. Our Max Heat units provide high heating capacity at -13 F to keep you comfortable. Look inside for our complete line

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

AIR CONDITIONER OUTDOOR UNIT AM036NXMDCR AM048NXMDCR AM053NXMDCR AM060NXMDCR. Product Specifications. Disassembly and Reassembly

AIR CONDITIONER OUTDOOR UNIT AM036NXMDCR AM048NXMDCR AM053NXMDCR AM060NXMDCR. Product Specifications. Disassembly and Reassembly SYSTM AIR CONDITIONR OUTDOOR UNIT AM036NXMDCR AM048NXMDCR AM053NXMDCR AM060NXMDCR AIR CONDITIONR CONTNTS Product Specifications Disassembly and Reassembly Refrigerant pipe installation Troubleshooting

More information

System Air Conditioner (Cooling and Heating) E S F I D DB A(2) ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH

System Air Conditioner (Cooling and Heating) E S F I D DB A(2) ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH INSTALLATION MANUAL RVXVHT080G Series RVXVHT100G Series RVXVHT120G Series RVXVHT140G Series RVXFHT080G Series RVXFHT100G Series RVXFHT120G Series RVXFHT140G Series DEUTSCH ENGLISH ESPAÑOL FRANÇAIS ITALIANO

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Learn more about Samsung air conditioner at:

Learn more about Samsung air conditioner at: Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner 2015 SAMSUNG New Single Air-Conditioner SINGLE SINGLE is a smart choice for saving both money and energy.

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W183CSA5 AS-W243CSA5 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual.

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

LG Ventilation Kit INSTALLATION MANUAL. Model: PTVK410 / PTVK420. website

LG Ventilation Kit INSTALLATION MANUAL. Model: PTVK410 / PTVK420. website website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG LG Ventilation Kit INSTALLATION MANUAL Model: PTVK410 / PTVK420 IMPORTANT Please read this installation manual completely

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL Duct Type Series MH FECA INSTALLATION MANUAL Duct Type Series MH FECA ENGLISH FRANÇAIS ESPAÑOL Free Joint Multi Air Conditioner (Cooling and Heating) E S F DB98-960A() Safety Precautions The following safety precautions must be

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com FREE JOINT MULTI Multi-Zone Mini Split Air Conditioner *Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰ quietside.com Ver 1-7.13 F DB, 43⁰F WB. FREE JOINT MULTI - Features and

More information

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMME06-111-10-06 MiNi-SMMS Design Manual Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H Compact 4-way ceiling cassette

More information

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...

More information

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax: Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE

More information

4. Disassembly and Reassembly

4. Disassembly and Reassembly 4. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1 Indoor Unit 4-1-1 MH FPEA /MH VP2-1 Front Panel 1) Stop the air conditioner

More information

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen d.c. or a.c.

More information

imagine the perfect environment

imagine the perfect environment imagine the perfect environment Split System Air Conditioning from Samsung Introduction 01 Samsung Brand Value Conducted by Interbrand on the world s top 100 brands $16.2 Bil $14.9 Bil $12.5 Bil $10.8

More information

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr Product Data -188-05 Split System (R-10A) Air Handler for Multi Split Inverter System 9,000 to,000 BTU/Hr Ceiling Concealed Type Indoor Unit: MXD8509A10N0 MXD851A10N0 MXD8518A10N0 MXD851A10N0 MXD85A10N0

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

AirtoWaterHeat Pump -TDM PLUS Hydro Unit

AirtoWaterHeat Pump -TDM PLUS Hydro Unit AirtoWaterHeat Pump -TDM PLUS Hydro Unit Installation manual AE090MNYDEH / AE090MNYDGH / AE160MNYDEH / AE160MNYDGH Thank you for purchasing this Samsung air conditioner. Before operating this unit, please

More information

LV Series. SEER 15+ Concealed Built in Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump LV Series SEER 15+ Concealed Built in Heat Pump EXPERTISE AND INNOVATION Daikin s slim duct systems offer a built in solution with the benefits of duct free technology. Installed similar to a traditional

More information

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com FUJITSU GENERAL AMERICA, INC. 353 Route 6 West, Fairfield, NJ 0700 airstagevrf.com Variable Refrigerant Flow (VRF) MultiSplit AC and HP AHRI Standard 30 ISO 900 ISO 00 Certified number : 0 00 8939 Certified

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8, Order No. MAC0605029C2 Air Conditioner CS-F18DTE5 CU-B34DBE5 CS-F18DTE5 CU-B34DBE8 CS-F24DTE5 CU-B43DBE8 CS-F28DTE5 CU-B50DBE8 Please file and use this manual together with the service manual for Model

More information

TECHNICAL NOTICE: Supplemental External Heat Control/Reduce Fan Operation Indoor Unit Firmware Version: (14/06/13) or newer

TECHNICAL NOTICE: Supplemental External Heat Control/Reduce Fan Operation Indoor Unit Firmware Version: (14/06/13) or newer Indoor Unit Firmware Version: (14/06/1) or newer Page 1 of 5 Added features with newest indoor unit firmware: External, supplemental heat source control Added fan control programming for satisfied zones

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LSN090HYV / LSU090HYV LSN120HYV / LSU120HYV CAUTION Before Servicing the unit, read the safety precautions

More information

"SET-FREE" FXG. Technical Catalog

SET-FREE FXG. Technical Catalog "SET-FREE" FXG Technical Catalog Outdoor Units: 8 & 10 HP Indoor Units Type: In-the-Ceiling 4-Way Cassette 2-Way Cassette Wall Floor Floor Concealed Ceiling Specifications in this catalogue are subject

More information

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Ductless Split Systems Wall-mounted, Multizone Heat Pump Ductless Split Systems Wall-mounted, Multizone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

SAMSUNG ELECTRONICS CO., LTD. 107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea Samsung Electronics (UK) Ltd, Euro QA Lab.

SAMSUNG ELECTRONICS CO., LTD. 107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea Samsung Electronics (UK) Ltd, Euro QA Lab. SAMSUNG ELECTRONICS CO., LTD. 107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea 506-723 Samsung Electronics (UK) Ltd, Euro QA Lab. Blackbushe Business Park. Saxony Way, Yateley, Hampshire. GU46

More information

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule # Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Page 1 of 7 Performance Power Compressor 95 F Ambient, Entering Temperature: 54 F, Leaving

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION What is Daikin VRV IV S-series? One flexible package Daikin VRV IV S-series

More information

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View) Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10

More information

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH E XEIPI IO E KATA TA H àçëíêìäñàü èé ìëíäçéçäö Wired Remote Controller

More information

REFRIGERATOR RB195BSSW RB195BSSB RB195BSVQ RB195BSBB RB215BSSW RB215BSSB RB215BSVQ RB215BSBB. Reversible Door Auto Ice-Maker Fridge Wire Box

REFRIGERATOR RB195BSSW RB195BSSB RB195BSVQ RB195BSBB RB215BSSW RB215BSSB RB215BSVQ RB215BSBB. Reversible Door Auto Ice-Maker Fridge Wire Box REFRIGERATOR RB195BSSW RB195BSSB RB195BSVQ RB195BSBB RB215BSSW RB215BSSB RB215BSVQ RB215BSBB REFRIGERATOR PRODUCT FEATURE Reversible Door Auto Ice-Maker Fridge Wire Box WARNING IMPORTANT SAFETY NOTICE

More information

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz 201812 Engineering Data Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V Heat Pump 60 Hz Heat Recovery 60 Hz RWEQ-TATJU (208 / 230 V, 60 Hz) RWEQ-TAYDU (460 V, 60 Hz) RWEQ-TAYCU

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S File Literature Number 1144-01-1 Installation Operation & Maintenance Manual CONTINUOUS REFRIGERANT DEHYDRATOR Model: CD-120 For use with Refrigerants R-11, R-123, R-12, R-22, R-134a

More information

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1 Gas Safety Products Merlin CT1250 Gas Interlock System Installation, operating and maintenance 28/10/2015 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.....

More information

Air conditgioner. conditioner. User Installation manual/installation manual ARHVSD. future reference.

Air conditgioner. conditioner. User Installation manual/installation manual ARHVSD. future reference. Air conditgioner conditioner User Installation manual/installation manual ARHVSD AM XMDCH Thank you you for purchasing for purchasing this Samsung this air conditioner. Samsung air conditioner. Before

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

SERVICE Manual CEILING TYPE AIR CONDITIONER INDOOR UNIT FH052EZA FH070EZA OUTDOOR UNIT FH052EZX FH070EZX. 1. Product Specifications

SERVICE Manual CEILING TYPE AIR CONDITIONER INDOOR UNIT FH052EZA FH070EZA OUTDOOR UNIT FH052EZX FH070EZX. 1. Product Specifications CEILING TYPE AIR CONDITIONER INDOOR UNIT FH052EZA FH070EZA OUTDOOR UNIT FH052EZX FH070EZX SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Trouble Shooting 3. Block Diagrams 4. Disassembly

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information