High static Pressure Duct Type Air-conditioner
|
|
- Roger Marsh
- 6 years ago
- Views:
Transcription
1 High static Pressure Duct Type Air-conditioner Part 1. Product Features In case the ceiling is super-high. Blowing pressure of Indoor Unit can reach 196Pa. The air conditioner delivers cold wind to every indoor corner even the ceiling is super-high. Multi-blowing outlets To satisfy your fitment s needs. Indoor Unit can be installed in various ways to give you a creative space. Fresh air drawn in Fresh air can be drawn in by the Indoor Unit, which improves the Indoor Air Quality greatly. Low noise operation The noise is remarkably low, even lower than Traditional Central Air Conditioner. 88
2 Part 2. Specification Model MHA-26CR MHA-26HR MHA-26CR MHA-26HR Factory Model CE-KF75T1W/Y CE-KFR75T1W/Y CE-KF75T1W/SY CE-KFR75T1W/SY Power supply Ph-V-Hz 1, V~, 50Hz 1, V~, 50Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz Capacity Btu/h Input W Cooling Rated current A EER Btu/w.h Capacity Btu/h Input W Heating Rated current A COP W/W Moisture Removal L/h Max. input consumption W Max. input current A Starting current A Model ZR34KH-PFJ-522 ZR36K3-PFJ-522 JT90BCBY1L JT90BCBY1L Type SCROLL SCROLL SCROLL SCROLL Brand COPELAND COPELAND DAKIN DAKIN Supplier COPELAND(SU ZHOU) COPELAND(SU ZHOU) DAKIN(XI AN) DAKIN(XI AN) Capacity Btu/h Compressor Input W Rated current(rla) A Locked rotor Amp(LRA) A Thermal protector Internal Internal Internal Internal Capacitor uf / / Refrigerant oil ml Model YLK160-4 YLK160-4 YLK160-4 YLK160-4 Brand WELLING WELLING WELLING WELLING Indoor fan motor Input W Capacitor uf Speed(hi/mi/lo) r/min 1210/1150/ /1150/ /1150/ /1150/1010 a.number of rows Indoor coil b.tube pitch(a)x row pitch(b) mm 25X X X X14.44 c.fin spacing mm d.fin type (code) Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium e.tube outside dia.and type mm Ф7.94, innergroove tube Ф7.94, innergroove tube Ф7.94, innergroove tube Ф7.94, innergroove tube f.coil length x height x width mm 700X300X60 700X300X60 700X300X60 700X300X60 g.number of circuits Indoor air flow (Hi/Mi/Lo) m 3 /h 1320/ / / /1120 Indoor noise level (Hi/Mi/Lo) db(a) 47/44 47/44 47/44 47/44 Dimension (W*H*D) mm 850X380X X380X X380X X380X660 Indoor unit Packing (W*H*D) mm 1075X495X X495X X495X X495X775 Net/Gross weight kg 52/57 52/57 52/57 52/57 Outdoor fan motor Model YDK65-6C1 YDK65-6C1 YDK65-6C1 YDK65-6C1 Brand Xijiao Xijiao Xijiao Xijiao Input W Capacitor uf
3 Speed r/min Outdoor coil a.number of rows b.tube pitch(a)x row pitch(b) c.fin spacing d.fin type (code) mm 25.4 X X X X22 mm Unhydrophilic aluminium Hydrophilic aluminium Unhydrophilic aluminium Hydrophilic aluminium e.tube outside dia.and type mm Ф9.53, bare tube Ф9.53, innergroove tube Ф9.53, bare tube Ф9.53, innergroove tube f.coil length x height x width mm 850X813X22 850X813X44 850X813X22 850X813X44 g.number of circuits Outdoor air flow m 3 /h Outdoor noise level db(a) Dimension(W*H*D) mm 895x860x x860x x860x x860x330 Outdoor unit Packing (W*H*D) mm 972X987X X987X X987X X987X406 Net/Gross weight kg 73/84 79/90 73/84 79/90 Refrigerant type R22 g Design pressure MPa 1.2/ / / /2.6 Liquid side mm(inch) Φ9.53(3/8") Φ9.53(3/8") Φ9.53(3/8") Φ9.53(3/8") Refrigerant piping Gas side mm(inch) Φ16 (5/8") Φ16 (5/8") Φ16 (5/8") Φ16 (5/8") Max. refrigerant pipe length m Max. difference in level m Connection wiring No No No No Plug type No No No No Thermostat type Electronic Control Electronic Control Electronic Control Electronic Control Operation temp 17~ ~ Ambient temp 18~ ~ Application area m Qty per 20 /40 /40'HQ set 28/65/74 28/65/74 28/65/74 28/65/74 Model MHA-36CR MHA-36HR MHA-48CR MHA-48HR Factory Model CE-KF105T1W/SY CE-KFR105T1W/SY CE-KF140T1W/SY CE-KFR140T1W/SY Power supply Ph-V-Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz Capacity Btu/h Cooling Heating Input W Rated current A EER Btu/w.h Capacity Btu/h Input W Rated current A COP Btu/w.h
4 Moisture Removal L/h Max. input consumption W Max. input current A Starting current A Model JT160BCBY1L JT160BCBY1L JT160BCBY1L JT160BCBY1L Type SCROLL SCROLL SCROLL SCROLL Brand DAKIN DAKIN DAKIN DAKIN Supplier DAKIN(XI AN) DAKIN(XI AN) DAKIN(XI AN) DAKIN(XI AN) Capacity Btu/h Compressor Indoor fan motor Indoor coil Input W Rated current(rla) A Locked rotor Amp(LRA) A Thermal protector Internal Internal Internal Internal Capacitor uf / / / / Refrigerant oil ml Model YLK400-4 YLK400-4 YLK400-4 YLK400-4 Brand WELLING WELLING WELLING WELLING Input W Capacitor uf Speed(hi/mi/lo) r/min 1250/1110/ /1110/ /1110/ /1110/1010 a.number of rows b.tube pitch(a)x row pitch(b) mm 25X X X X14.44 c.fin spacing mm d.fin type (code) Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium e.tube outside dia.and type mm Ф7.94, innergroove tube Ф7.94, innergroove tube Ф7.94, innergroove tube Ф7.94, innergroove tube f.coil length x height x width mm 900X300X60 900X300X60 900X300X60 900X300X60 g.number of circuits Indoor air flow (Hi/Lo) m 3 /h 2000/ / / /1600 Indoor noise level (Hi/Lo) db(a) 50/47 50/47 50/47 50/47 Dimension (W*H*D) mm 1200X380X X380X X380X X380X660 Indoor unit Packing (W*H*D) mm 1425X495X X495X X495X X495X775 Net/Gross weight kg 65/72 65/72 65/72 65/72 Model YDK65-6C-WL;YDK65-6FC YDK65-6C-WL;YDK65-6FC YDK65-6C-WL;YDK65-6FC YDK65-6C-WL;YDK65-6FC Brand Welling Welling Welling Welling Outdoor fan motor Input W Capacitor uf 3.5x2 3.5x2 3.5x2 3.5x2 Speed r/min Outdoor coil a.number of rows b.tube pitch(a)x row pitch(b) mm 25.4 X X X X22 c.fin spacing mm d.fin type (code) Unhydrophilic aluminium Unhydrophilic aluminium Unhydrophilic aluminium Unhydrophilic aluminium e.tube outside dia.and type mm φ9.53,innergroove tube Ф9.53, bare tube φ9.53,innergroove tube Ф9.53, bare tube f.coil length x height x width mm 715X1220X22 715X1220X44 715X1220X22 715X1220X44 g.number of circuits Outdoor air flow m 3 /h Outdoor noise level db(a)
5 Dimension(W*H*D) mm 940x1245x x1245x x1245x x1245x360 Outdoor unit Packing (W*H*D) mm 1018X1377X X1377X X1377X X1377X434 Net/Gross weight Kg 110/ / / /127 Refrigerant type g Design pressure MPa 2.6/ / / /1.2 Liquid side mm(inch) Φ12.7(1/2") Φ12.7(1/2") Φ12.7(1/2") Φ12.7(1/2") Gas side Refrigerant piping mm(inch) Φ19.0(3/4") Φ19.0(3/4") Φ19.0(3/4") Φ19.0(3/4") Max. refrigerant pipe length m Max. difference in level m Connection wiring No No No No Plug type No No No No Thermostat type Electronic Control Electronic Control Electronic Control Electronic Control Operation temp Ambient temp 18~ ~ Application area m Qty per 20 /40 /40'HQ set 22/46/46 22/46/46 22/46/46 22/46/46 Model MHA-24HRN2 MHA-24HRN2 MHA-30HRN2 Factory Model CE-KFR71T1W/N2Y CE-KFR71T1W/N2SY CE-KFR90T1W/N2SY Power supply Ph-V-Hz 1, V~, 50Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz Cooling Heating Capacity Btu/h Input W Rated current A EER Btu/w.h Capacity Btu/h Input W Rated current A COP Btu/w.h Moisture Removal L/h Max. input consumption W Max. input current A Starting current A Compresso r Model HQ034PAA C-SBN263H8A C-SBN263H8A Type SCROLL Scroll Scroll Brand LG SANYO SANYO Supplier LG(KOREA) SANYO SANYO Capacity Btu/h Input W
6 Indoor fan motor Rated current(rla) A Locked rotor Amp(LRA) A 61 Thermal protector INTERNAL TYPE INTERNAL TYPE INTERNAL TYPE Capacitor uf 60 / / Refrigerant oil ml 750 DAPHN-E FV68S 1700 DAPHN-E FV68S 1700 Model YLK160-4 YLK160-4 YLK160-4 Brand WELLING WELLING WELLING Input W Capacitor uf Speed(hi/mi/lo) r/min 1210/1150/ /1150/ /1150/1010 a.number of rows b.tube pitch(a)x row pitch(b) mm 25X X X14.44 c.fin spacing mm Indoor coil d.fin type (code) Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium e.tube outside dia.and type mm Ф7.94, innergroove tube Ф7.94, innergroove tube Ф7.94, innergroove tube f.coil length x height x width mm 700X300X60 700X300X60 700X300X60 g.number of circuits Indoor air flow (Hi/Lo) m 3 /h 1320/ / /1150 Indoor noise level (Hi/Lo) db(a) 47/44 47/44 47/44 Dimension (W*H*D) mm 850X380X X380X X380X660 Indoor unit Packing (W*H*D) mm 1075X495X X495X X495X775 Outdoor fan motor Outdoor coil Net/Gross weight Kg 52/57 52/57 52/57 Model YDK53-6H YDK53-6H YDK53-6H Brand WELLING WELLING WELLING Input W Capacitor uf Speed r/min a.number of rows b.tube pitch(a)x row pitch(b) mm 25.4x x x22 c.fin spacing mm d.fin type (code) Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium e.tube outside dia.and type mm Ф9.53, innergroove tube Ф9.53,innergroove tube Ф9.53, innergroove tube f.coil length x height x width mm 850X813X44 850*813*44 850X813X44 g.number of circuits Outdoor air flow m 3 /h Outdoor noise level db(a) Dimension(W*H*D) mm 895X860X X860X X860X330 Outdoor unit Packing (W*H*D) mm 972X987X X987X X987X406 Net/Gross weight Kg 79/90 79/90 79/90 Refrigerant type g R407C/2500 R407C/2350 R407C/2350 Design pressure MPa 1.2/ / /3.5 Liquid side/ Gas side mm(inch) Ф9.53(3/8")/Ф16(5/8") Ф9.53(3/8")/Ф16(5/8") Ф9.53(3/8")/Ф16(5/8") Refrigerant Max. refrigerant pipe length piping m Max. difference in level m Connection wiring No No No Plug type No No No Thermostat type Electronic Control Electronic Control Electronic Control 93
7 Operation temp Ambient temp Application area m Qty per 20 /40 /40'HQ set 28/65/74 28/65/74 28/65/74 Model MHA-36HRN2 MHA-48HRN2 MHA-60HRN2 Factory Model CE-KFR105T1W/N2SY CE-KFR140T1W/N2SY CE-KFR160T1W/N2SY Power supply Ph-V-Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz 3N, 380V~, 50Hz Cooling Heating Capacity Btu/h Input W Rated current A EER Btu/w.h Capacity Btu/h Input W Rated current A COP Btu/w.h Moisture Removal L/h Max. input consumption W Max. input current A Starting current A Model C-SBN303H8A C-SBN373H8A C-SBN453H8A Type Scroll SCROLL Scroll Brand SANYO SANYO SANYO Supplier SANYO(DA LIAN) SANYO(DA LIAN) SANYO(DA LIAN) Capacity Btu/h Compressor Input W Rated current(rla) A Locked rotor Amp(LRA) A Thermal protector INTERNAL TYPE INTERNAL TYPE INTERNAL TYPE Capacitor uf / / / Refrigerant oil ml DAPHN-E FV68S DAPHN-E FV68S 1700 Indoor fanmodel YLK400-4 YLK400-4 YLK400-4 motor Brand WELLING WELLING WELLING 94
8 Indoor coil Input W Capacitor uf Speed(hi/mi/lo) r/min 1250/1110/ /1110/ /1110/1010 a.number of rows b.tube pitch(a)x row pitch(b) mm 25X X X14.44 c.fin spacing mm d.fin type (code) Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium e.tube outside dia.and type mm Ф7.94, innergroove tube Ф7.94, innergroove tube Ф7.94, innergroove tube f.coil length x height x width mm 900X300X60 900X300X60 900X300X60 g.number of circuits Indoor air flow (Hi/Lo) m 3 /h 2000/ / /2200 Indoor noise level (Hi/Lo) db(a) 50/47 50/47 50/47 Indoor unit Outdoor fan motor Dimension (W*H*D) mm 1200X380X X380X X380X660 Packing (W*H*D) mm 1425X495X X495X X495X775 Net/Gross weight kg 65/72 65/72 65/72 Model YDK250-6D-WL YDK65-6-WL;YDK65-6F YDK65-6-WL;YDK65-6F Brand WELLING WELLING WELLING Input W Capacitor uf x2 3.5x2 Speed r/min a.number of rows b.tube pitch(a)x row pitch(b) mm 25.4x X x22 c.fin spacing mm Outdoor coil d.fin type (code) Unhydrophilic aluminium Unhydrophilic aluminium hydrophilic aluminium e.tube outside dia.and type mm Ф9.53,innergroove tube Ф9.53, bare tube Ф9.53, innergroove tube f.coil length x height x width mm 955*915*44 715X1220X44 715*1220*44 g.number of circuits Outdoor air flow m 3 /h Outdoor noise level db(a) Dimension(W*H*D) mm 990*960* X1245X *1245*400 Outdoor unit Packing (W*H*D) mm 1120*1090* X1377X *1377*434 Net/Gross weight kg 101/ / /125 Refrigerant type g R407C/2700 R407C/4050 R407C/4300 Design pressure MPa 1.2/ / /3.5 Refrigerant piping Liquid side/ Gas side mm(inch) Ф12.7/Ф19.0 Ф12.7/Ф19 Ф12.7/Ф19 Max. refrigerant pipe length m Max. difference in level m Connection wiring NO No No Plug type NO No No Thermostat type Electrolic control Electronic Control Electronic Control Operation temp Ambient temp -10 ~ Application area m Qty per 20 /40 /40'HQ set 24/54/62 22/46/46 22/46/46 95
9 Part 3. Electric Control Functions 1. Performance Index No. Item Index 1 Applicable Voltage Range V~ (SINGLE PHASE) V~ (3- PHASE) 2 A/C Frequency 50Hz 3 Working environment temperature -7 C- +45 C 2. Main Parts Introduction 2.1 Operation Mode Operation mode can be set into auto, cooling, heating, dehumidifying and fan mode. 2.2 Temperature range can be set between: 17 C -30 C 2.3 Compressor Auxiliary start-up function: when the compressor starts up with single phrase, the main chip output will be in high level. 4 seconds after start-up circuit is engaged, the main chip output will be in low level and the start-up circuit shut down. 2.4 Indoor Fan The motor is a tapping motor with iron-made outer cover and high, low and fine tuning speed selections driven by three relays separately. The main chip will act when its output is high level. Under any circumstances, only one fan speed is allowed. 2.5 Outdoor Fan The motor is a tapping motor with iron-made outer cover and high, low speed options controlled by relays separately. The main chip acts when its output is high level. 2.6 Buzzer It will buzz when its driving port in the main chip outputs high level It will buzz twice with each lasting 0.5 second at 0.5 intervals when the main frame receives remote start-up signal It will buzz once for 1 second when receiving turn-off signal It will buzz for 0.5 second once receiving other signal It will not buzz when receiving abnormal signal. 2.7 Indicator There are 4 indicators: operating indicator, timer indicator, water level warning indicator, defrosting indicator 96
10 and pre-heating indicator (wind-delivery indicator for cooling-only A/C) The light-emitting diode driven by the main chip will light when the level is low LED indicates errors when protection is in effective. 2.8 Four-way Valve It is controlled by relays. The main chip acts when output is high level. 2.9 Heating Condition for Crankcase The crankcase will be heated when the temperature of the outer pipe is below 7 C and the compressor is off The crankcase will no longer be heated when the temperature of the outer pipe is over 15 C The crankcase will no longer be heated when the compressor is on Selection Channel for Quick Check The main frame will enter the quick check status if the channel is in low position when energizing. 1 minute will be shortened to 1 second during this period, however, other status will remain unchanged. 3. Operation Modes and Functions 3.1 Manual Operation The manual operation mode is controlled through manual pad in the wind in-take grid, including such two modes as manual action and manual cooling. Push the manual pad for each switchover, the order for which is shown below: REMOTE CONTROL MANUAL ACTION MANUAL COOLING Manual Cooling Under this mode, no remote control signal will be received The compressor is started up unconditionally and the rotating speed of indoor and outdoor fans is set to be in high and forced cooling operation. At the same time, the wind grille is forced to swing (irrelevant to temperature setting and environment temperature) and will be automatically switched over to manual mode 30 minutes later, under which manual mode will be in effective Under this mode, the buzzer will buzz twice with each lasting 0.5 second at 0.5 interval. During the first 30 minutes of unconditional forced cooling operation, the operation indicator will blink at 0.5Hz. In the process of switchover to manual action mode, the buzzer buzzes for 0.5 second and the indicator is illuminated Under this mode, the corresponding protections are in effective (3- minute delayed start-up, over current, outdoor protection and evaporator low temperature protection.). Corresponding protection will act once any protection is in active. Push manual pad once to end this mode and enter the remote control pending status. The buzzer will buzz for 1 second and the indicator turn off Manual Action Under this mode, the remote signal will be received and corresponding actions will be taken accordingly upon the receipt of the remote signal On entering this mode, the buzzer will buzz for 0.5 second and the indicator on The system will operate under the auto mode whose temperature is set to be 24 C and at the same time, the wind grille will swing automatically Under this mode, corresponding protections are in effective. Push manual pad to end this mode and switch over to manual cooling mode. 97
11 3.2 Heating Mode Four-way valve opens at once, while defrosting process closes Condition for the compressor action: (Ts = set temperature, Ta = room temperature) Condition Compressor Outdoor fan Room temp. up Room temp. down Indoor Fan Action Ta > Ts+4 Off Off Ta <Ts+4 On On Ta < Ts+3 On On Ta >Ts+3 Off Off Anytime remote switchover for fan speed among high/low/auto(anti-cold air function takes priority) Anti-cold air: Switchover between fan speed and fine tune can be set according to temperature of evaporator pipe. Condition Indoor fan speed T= Indoor exchanger temp. Indoor exchanger temp. up T<25 C Off 25 C <T<32 C Breeze Indoor exchanger temp. down T>32 C Setting fan speed T> 30 C Setting fan speed 15 C <T<30 C Breeze T<15 C Off During anti-cold air period, if indoor fan is shut down, then pre-heating/defrosting lamp is on. Once indoor fan starts, pre-heating/defrosting lamp will be off Auto fan of indoor fan under heating mode. Condition (T=Indoor Temp.-Setting Temp.) Room temp. up Room temp. down 3.3 Defrost (only available to heating mode) Defrosting Conditions Low temperature defrosting condition: T<3 T>3 Indoor fan speed High Low T> 1 Low T<1 Accumulated operating time when temperature of outdoor heat exchanger coil T3 is below -2 C reaches up to over 40 minutes High temperature defrosting condition: Under high temperature protection of evaporator, the time when outdoor fan is shut down but compressor is not has been accumulated for up to 90 minutes. It is considered that defrosting is performed when either or is met Defrosting Action Four-way valve, indoor fan, outdoor fan are shut down. Compressor keeps on continuously Ending Of Defrosting Condition It is considered that defrosting condition is ended when any of the conditions is met: Operating current of compressor reaches 1.5Ie(Rating current) Time of defrosting reaches 10 minutes Temperature of outdoor coil T3 is up to 20 C Ending Action of Defrost Outdoor fan and four-way valve are open. High 98
12 Compressor keeps on continuously Indoor fan acts according to anti-cold air function Defrosting/pre-heating lamp continues to be on until indoor fan starts up. 3.4 Cooling Mode Four-way valve is closed. If four-way valve is open before the machine enters cooling mode, then four-way valve will be closed at the first time the compressor starts under the cooling mode Conditions for the compressor and outdoor fan action (Ts = set temperature, Ta=room temperature) Condition Compressor Outdoor fan Room Temp. up Room Temp. down Action of Indoor Fan Ta> Ts+1 On On Ta<Ts+1 Off Off Ta> Ts On On Ta<Ts Off Off HIGH/LOW/AUTO fan can be switched over for your comfort Auto fan under cooling mode. Condition (T=Indoor Temp.-Setting Temp.) Temp. up Temp. down T<4 T>4 Indoor fan speed Low High T> 1 High T<1 Low 3.5 Dehumidifying Mode Dehumidifying mode is the cooling operation, under which the indoor fan is high and outdoor fan is low If certain protective condition is met, operation will be carried out. 3.6 Auto Mode Under auto mode, the indoor fan is set to be auto (refer to auto fan under cooling, heating) When entering auto mode, the heating, fan only or cooling operation will be automatically chosen according to the room temperature Ta and the set temperature Ts When Ta < Ts - 1 c, it performs the heating operation with a set temperature of Ts - 10 c (refer to the heating mode). However the cool only model will be in low fan When Ts + 2 c Ta Ts - 1 c, it will be in low fan When Ta > Ts +2 c, it performs the cooling operation with a set temperature of T (refer to the cooling mode) After one mode is chosen, if the condition Ta > Ts+1 c or Ta < Ts - 4 c lasts for 15 minutes, meanwhile the compressor doesn't start up within consecutive 15 minutes, the operation mode will be re-chosen according to the Ta and Ts If certain condition is met, then the corresponding protective function will be executed. 3.7 Fan Only Mode Under this mode, four-way valve, compressor and outdoor fan are shut down High/Low/Auto fan can be switched over through manual control. Auto fan will be controlled in line with cooling auto fan with temperature set to be 23 C Under this mode, operation lamp will be on. 99
13 4. Other Functions 4.1 LED Display Operation lamp, timer lamp, defrosting/pre-heating lamp, and water level alarm lamp Operation Lamp When the operation is recovering, it will blink at 1 Hz. After the air-conditioner is on, the lamp will keep on. After the air-conditioner is off, the lamp will be off. When the air-conditioner is switched over from manual cooling to remote control, the lamp will be off Timer Lamp During timer operation, it will be on Defrosting/Pre-Heating Lamp When heat pump model performs defrosting or anti-cold air, it will be on In addition to displaying normal operation status, these lamps can be combined to indicate various errors. 4.2 Timer The machine should be provided with max. Interval of 24h and min. resolution ratio of 15 minutes. Off timer: Timer on: set the start-up before closing down the A/C. At this moment, operation lamp will be off. Timer indicator is on and the A/C will start when the set time is up Off timer: if closedown time for the A/C is set, the A/C will close down when the set time is up On/off timer: set start-up time and closedown time before closing the A/C, it will start when the set start-up time is up and close down when the set closedown time is up Off/on timer: if both closedown time and start-up time are set, it will close down when the set time is up and start automatically when the set start-up time is up. Note: The timer is valid for one operation of the A/C. 5. Trouble Shooting 5.1 Protective Function minute delay for the compressor start-up. At the beginning of energizing or after the stop of the compressor, 3-minute delay will be needed to start the compressor. When switching over between cooling/heating mode, the compressor stops automatically Compressor current overload protection Condition Indoor fan Compressor Outdoor fan Remark Amps up Amps down I<I 2 On On On I 2 <I< I 3 On Off Off After 5 Minutes I 3 <I Off Off After 3 Seconds I 3 <I Off Off After 3 Seconds I 1 <I< I 3 Off Off After 5 Minutes I< I 1 On On On Remark :Ie: rating current; I 1 :1.3 time Ie; I 2 :1.5 time Ie; I 3 :2.0 time Ie The compressor and outdoor fan closed for protection purpose will restart after 3 minutes During the protection, the indoor fan continues working at a set speed, while the anti-cold air function of heating and the compressor will be 3 minutes delayed to shut down for protection. 100
14 When there are 4 times compressor protection within one hour, the A/C will be shut down, meanwhile the operation light and timer light will be turned on, the defrosting light flashes at a frequency of 0.5Hz. This situation will be recovered only when power is switched off Evaporator protection against high temperature(heating mode) Indoor exchanger temp. up Indoor exchanger temp. down Condition Compressor Outdoor fan T= Indoor exchanger temp. T<50 C On On 50 C <T<56 C On Low speed 56 C <T<60 C On Off T>60 C Off Off T>54 C Off Off 45 C <T<54 C On Off T<45 C On On Note: During protection, the indoor fan continues operating at a setting speed, while the anti-cold air function of heating and the compressor will be 3 minute delayed to shut down for protection Evaporator Protection against low temperature(cooling mode) When the evaporator pipe temperature 2 c and this lasts for 5 minutes, the compressor and outdoor fan will be shut off When the evaporator pipe temperature 7 c, it recovers When T3<31 c, outdoor fan performs low fan When T3 31 c, outdoor fan performs high fan The restart of the compressor shall execute the delay protection Anti-cold air protection Only available to heating mode, including heating mode, heating operation under auto mode Condenser high temperature protection Only available to cooling (incl. cooling mode, cooling operation under auto mode) and dehumidifying mode Action condition Outdoor exchanger temp. up Outdoor exchanger temp. down Condition Compressor Outdoor fan T=Outdoor exchanger temp. T>65 C Off Off Delay protection should be performed when the compressor restarts Single Phrase Compressor Start-up Control Single phrase compressor must have start-up circuit: T<56 C On On T>60 C Off Off T<50 C On On 1 second before the start-up of the compressor, the chip will output high level consecutively for 5 seconds in order to engage the start-up capacitor that will be open afterwards Outdoor Protection When outdoor protection signal is high level, outdoor door unit will perform protection: the whole machine will be shut down while the LED will indicate the corresponding protection signal. 101
15 The A/C will recover if outdoor errors are eliminated after the outdoor protection occurs. 102
16 5.2 Self-diagnosis Indoor unit No. Type Contents LED Flashing Remark 1 protection Over current protection of the compressor occurs 4 times in 1h Lamps of operation, timer, defrosting (only fan) flashing simultaneously at 5Hz. 2 protection Outdoor protection (absent phrase, phrase All lamps flashing at 5Hz sequence and temperature protection) 3 error Room temperature sensor checking channel Timer lamp flashing at 5Hz is abnormal 4 error Evaporator sensor checking channel is abnormal Operation lamp flashing at 5Hz 5 error Condenser sensor checking channel is abnormal Defrosting lamp flashing at 5Hz 6 error Temperature fuse is melt(reserved) Operation lamp and timer lamp flashing at 5Hz Whole unit is shut down. It cannot recover unless power is cut off Recover automatically after errors are eliminated LEDs for the indication of outdoor trouble(3 phase type,3hp) Type Contents LED1 LED2 LED3 Normal Off Off On Trouble Phase sequence On Off On Trouble Overload of current Off On On Trouble Lack of phase On On On Trouble Protection of pressure On On On LEDs for the indication of outdoor trouble(3 phase type,5hp) Type Contents LED1 LED2 LED3 Trouble Phase sequence Flash Off Off Trouble Lack of phase Flash Off Off Trouble Protection of pressure Flash Flash Off Trouble Overload of current Off Off Flash Trouble Open-circuit and short-circuit trouble of T3 Off Flash Flash Trouble Open-circuit and short-circuit trouble of T4 Off Flash Off Trouble High temperature protection of condenser Flash Flash Flash 103
17 CN 3 8 CN 3 7 Y & G B L A C K RE D Part 4. Wiring Diagram 1 MHA-26CR ( V~) INDOOR UNIT: L N 1 2(N) 3 4 OUTDOOR UNIT: RT 3 XS 1 XP CURRE NT DET ECT OR B OA RD CN3 6 CN3 5 T 5 F AN2 RE D CODE P ART NAME WHI T E WHI T E X T 6 CAP B ROWN GR E N B L A CK Y E L L OW B L A CK R E D X T 4 BL ACK RE D A1 R E D K M1 RE D RE D A2 B L A CK BL ACK Y& G Y& G C S COMP B L A C K R C1 WHI T E XS 3 XP 3 XS 4 XP 4 X T T O I NDOOR UNI T T O I NDOOR UNI T 104
18 2 MHA-26HR( V~) INDOOR UNIT: OUTDOOR UNIT: B. H. T CRANKCASE HEATER 105
19 3 MHA-26CR (380V, 3N~) INDOOR UNIT: OUTDOOR UNIT: 106
20 4 MHA-26HR (380V, 3N~) INDOOR UNIT: OUTDOOR UNIT: 107
21 RED 5 MHA-36CR,MHA-48CR INDOOR UNIT: OUTDOOR UNIT: CN301 UNI T3 TT1 XS8 XP8 3 OR2 RT3 CN304 XP7 XS7 3 CN305 TOINDOORUNI T XP3 CN303 FAN2 CN302 RED BLUE KM1 A2 A RED K1 XT5 FAN3 4 WHI TE RED V U COMP W XT7 XT4 RED TOINDOORUNI T XT1 TOINDOORUNI T XT1 108
22 RED 6 MHA-36HR,MHA-48HR INDOOR UNIT: OUTDOOR UNIT: XS8 XP8 CN301 UNI T3 TT1 CN304 CN302 3 OR2 CN305 CN303 RT3 XP7 XS7 3 TOI NDOORUNI T XP3 FAN2 RED 4 BLUE A1 KM1 A WHI TE V COMP RED RED RED U HEAT K1 XT5 BLUE XT6 FAN3 W XT7 S. V. XT4 TOI NDOORUNI T XT1 RED YELLOW TOI NDOORUNI T XT1 109
23 7 MHA-24HRN2( V~) INDOOR UNIT: CAP1 CN1- CN16 T4 FAN1 RT1 RT2 XP1- XP3 XS1- XS3 XT1 L N XT1 OUTDOOR UNIT: CAP1 VALVE CAP1 R S Y&G C WHI TE RED BLACK XP1 RT3 XS1 RED XT1 1 N
24 8 MHA-24HRN2, MHA-30HRN2 (380V,3N~) INDOOR UNIT: CAP1 CN1-16 T4 FAN1 PUMP RT1 RT2 XP1- XP7 XS1- XS7 XT1 XT3 A B C N XT1 OUTDOOR UNIT: 111
25 9 MHA-36HRN2(380V,3N~) INDOOR UNIT: OUTDOOR UNIT: H- PRO K1 XS9 XP9 XS8 XP8 CN206 CN203 CN208 COMP FAN3 RT4 RT3 CN201 CN100 CN200 T201 CAP3 S. V. XT5 KM1 KM1 HEAT S. V. XT4 XT7 XT5-7 FAN3 H- PRO T201 COMP RT3 CAP3 XT6 HEATER XS8-9 XP8-9 CN K1 XT XT3 N RT4 XT3 T5 112
26 10 MHA-48HRN2,MHA-60HRN2 INDOOR UNIT: OUTDOOR UNIT: H- PRO K1 XS9 XP9 XS8 XP8 CN206 CN203 CN208 COMP FAN3 FAN4 RT4 RT3 CN201 CN100 CN200 CAP3 CAP4 S. V. XT5 KM1 KM1 HEAT S. V. XT2 XT7 XT5-7 FAN3 H- PRO T201 COMP RT3 CAP3 XT6 HEATER XS8-9 XP8-9 CN FAN4 K1 XT XT1 N RT4 XT1 CAP4 T5 113
27 ITEM C1 C3,C4 CAP1 CAP2 CNO-16 COMP CT F1+F2 FAN1 FAN2 K1 K2 K3 K4 KM1 KM2,KM3 M PUMP R1-R3 RS RT1 RT2,RT3 S.V.T KP1 XS1-XS3 XT1,XT2,XT4 XT3 XT5 T4 NAME CRANECASE HEATING CAPACITY FOR COMPRESSOR RUNNING CAPACITY FOR COMPRESSOR STARTING CAPACITY FOR INDOOR FAN CAPACITY FOR OUTDOOR FAN P.C.BOARD SOCKET COMPRESSOR CURRENT MUTUAL INDUCTOR THERMAL CUT-OUT INDOOR FAN OUTDOOR FAN TEMPERATURE PROTECTION SWITCH PIPE OVERLAOD SWITCH WATER LEVEL WARNING SWITCH THERMAL PROTECTION SWITCH A/C CONTACTOR RELAY SWING MOTOR DRAIN PUMP ELECTRIC HEATING PIPE RELEASE RESISTANCE ROOM TEMPERATURE SENSOR PIPE TEMPERATURE SENSOR 4-WAY VALVE MIDDLE CONNECTOR MIDDLE CONNECTOR 6-WAY TERMINAL BLOCK 3-WAY BIGGER TERMINAL BLOCK MIDDLE TERMINAL BLOCK TRANSFORMER 114
28 Part 5. External Static Pressure of the Indoor Fans Pa Pa m 3 MHA-18HR High speed Med. speed Low speed m 3 High speed Med. speed Low speed MHA-26H(C)R MHA-24H(C)R(N2) Pa High speed Med. speed m 3 MHA-36(48)H(C)R(N2) Low speed 115
Ceiling & Floor type Unit
Ceiling & Floor type Unit Part 1. Product Features Quietest operation, low noise. Thin design, space-saving. Easy to operate, remote control. 16 Part 2. Specification Model MUA-18HRN2 MUA-24HRN2 MUA-24HRN2
More informationService Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM
Service Manual Multi Split Type Heat Pump Air Conditioners Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM CONTENT 1. Product features 2. Specification 3. Dimensions 4. Refrigeration cycle
More informationFloor-Standing Type(E Series)
Floor-Standing Type(E Series) Model: MFE-60CE, MFE-60AE Part 1. Product Features With a spiral shape, the computer-aided simulation designed air passage system can efficiently reduce noise. The Soft touch
More informationFour-way Cassette Type
Four-way Cassette Type Part 1. Product Features 1) Low operation noise ---Streamline plate ensures quietness ---Creates natural and comfortable environment 2) Efficient cooling ---Equal, fast and wide
More informationFloor-Standing Type(S2 Series)
Floor-Standing Type(S2 Series) Model: MFS2-24CR(N2), MFS2-24HR(N2), MFS2-24AR(N2), MFS2-48CR(N2), MFS2-48AR(N2) Part 1. Product Features Strong air supply. Wide angle and long distance air supply. Easy
More informationTECHNICAL & SERVICE MANUAL
TECHNICAL & SERVICE MANUAL CASSETTE TYPE AIR-CONDITIONER (One-way cassette) FSK-94HF FI-SM-040830 One-way Cassette Air-conditioner Table of Contants Part 1. Product Features 2 Part 2. Specification 3 Part
More information1. Features Specification Dimensions Refrigeration cycle diagram Operation limits
GLORY (ECO) STAR SERIES 1. Features 60 2. Specification 61 61 3. Dimensions 67 67 4. Refrigeration cycle diagram 70 70 5. Operation limits 71 6. Wiring diagram 72 7. Troubleshooting 80 8. Electronic function
More informationCassette SERVICE MANUAL. YKHC 18 to 48 YKHC 18 YKHC 24 YKHC 30 YKHC 36 YKHC 48 SM-YKHC-18-48GB 03-07
Cassette YKHC 18 to 48 SERVICE MANUAL YKHC 18 YKHC 24 YKHC 30 YKHC 36 YKHC 48 SM-YKHC-18-48GB 03-07 How to read the model? * * * Y K H C 24 F S B A A A Range: F = Floor standing H = High wall M = Master
More informationWindow Y9USC/E 09 / 12 / 18 B5R
Window Y9USC/E 09 / 12 / 18 B5R SERVICE MANUAL Y9USC-09 B5R; Y9USE-09 B5R Y9USC-12 B5R; Y9USE-12 B5R Y9USC-18 B5R; Y9USE-18 B5R SM-Y9USC-E-09-18GB 03-07 1. Precaution... 2 1.1 safety Precaution... 2 1.2
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More informationMODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S
MODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S Compact Four-way Cassette Type 1. Features... 2. Specification... 3. Dimension... 4. Service Space... 5. Wiring Diagram...
More information[U] Serie MHB / MHA Manual de Ingeniería
[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance
More informationBlanc ON-OFF Series. Service Manual 2016
Blanc ON-OFF Series Service Manual 2016 MSMA1A-07HRN1 / MOAB02-07HN1 MSMA1A-09HRN1 / MOAB02-09HN1 MSMA1B-12HRN1 / MOBA01-12HN1 MSMA1C-18HRN1 / MOBA03-18HN1 MSMA1D-24HRN1 / MOCA02-24HN1 1 Blanc On-off DM16-01.01.07en
More informationUCV CONDENSING UNITS SPECIFICATIONS 1. Specifications
UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated
More informationMulti Inverter Air Conditioning Condensing Units - Summary
Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1
More informationTechnical & service manual 2005
HVAC EUROPE SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical & service manual 005 R40a Wall Mounted [Models] GCM07N niet leverbaar GHM07N niet leverbaar GCM09N GHM09N GCMN GHMN GCM8N GHM8N GC(H)M Series
More informationMiraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.
Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. High Efficiency Green Slim Line Ceiling Concealed Ducted Split Systems Cool Only Rev. August 2015 12K - 18K - 24K - 30K - 36K - 42K - 48K - 60K IAQ
More information[U] Serie MOV. Manual de Ingeniería
[U] Serie MOV Uniidades Condensadoras (Fllujjo Verttiicall) 6..3,, 8 y 12..5 Ton Manual de Ingeniería - 112- Outdoor Units_MOV 1. Specifications.... 2. Dimension... 3. Service Space. 4. Piping Diagrams
More informationAIR HANDLER UNIT R410A 60HZ ON-OFF CONTROL
TM_AHU_60R410A_ONOFF_T_SA_NA_171205 AIR HANDLER UNIT R410A 60HZ ON-OFF CONTROL 2017 TECHNICAL MANUAL Table of Contents Page 1. Specifications... 4 1. Model Reference 2. General Specifications 3. Dimensional
More informationMobile Type Air Conditioner
Mobile Type Air Conditioner 1. Features 2. Specification 3. Wiring diagram 4. Trouble shooting 5. Electronic function 36 1. Features 1.1The currently manufactured mobile air conditioners include the following
More informationService Manual. Air Conditional
Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30HM -3 - CONTENTS SPECIFICATION...
More informationPRODIGY 3D Inverter. Technical Manual
PRODIGY 3D Inverter Technical Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Function and specifications... 5 3. Dimension... 10 3.1 Indoor Unit... 10 3.2 Outdoor Unit...
More informationSERVICE MANUAL UNI ON/OFF ASC-60A
SERVICE MANUAL UNI ON/OFF ASC-60A The specifications, designs, and information in this book are subject to change without notice for product improvement. Model Power supply Cooling Heating Indoor fan motor
More informationCover. Service Manual PAC9037 PAC12037 PAC13037 PAC18037
Cover Service Manual PAC9037 PAC12037 PAC13037 PAC18037 Content Content 1. Precaution 2 1.1 Safety Precaution 2 1.2 Warning 2 2. Function 4 3. Dimension 6 3.1 Indoor unit 6 3.2 Outdoor unit 6 4. Refrigerant
More informationCorona Plus varmepumper
Corona Plus varmepumper SERVICEMANUAL MSC-09HRDN1-QD0E MSC-12HRDN1-QC6E CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 4 3. Dimension... 6 3.1 Indoor Unit... 6 MSC-09HRDN1-QD0(E)
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationSERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH
SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH Outdoor Units - appearance 18,000Btu/h 30,000~36,000Btu/h 24,000Btu/h 48,000Btu/h-60,000Btu/h Model Names of Outdoor Units
More informationInstallation, Operation & Maintenance
Installation, Operation & Maintenance Contura 5G Series R410a High Ambient & High Efficiency MS-SVX041A-EN 1 Contents 1. Precaution 1.1 Safety Precuation 03 1.2 Warning 03 2. Product Specifications 06
More informationService manual. MIV V4+ Mini
DM12-01.01.05en Service manual MIV V4+ Mini DC INVERTER R410A (~220V, 50Hz, 1Ph) MVUH80A-VA1 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 6 Part 3 Installation... 44 DM12-01.01.05en
More informationPart 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...
MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information
More informationWORKING PROGRAM. Heating dehumidifying cooling T 27
I. Functions and Operation Modes WORKING PROGRAM The operation modes of the unit run like the following: Auto cooling dehumidifying heating --------------------------------------- Note: Cooling only unit
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More informationR410A50Hz Universal Outdoor Series Technical Manual
Outdoor Unit R410A 50Hz Universal Outdoor Series Technical Manual 2013 Version LCAC/2.0/201308 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Content PART 1.General Information... 1 1.Nomenclature...
More informationBTU Units WORKING PROGRAM MANUAL
9000-24000BTU Units WORKING PROGRAM MANUAL SUMMARIZE FUNCTIONS & OPERATION MODES TIMER, SLEEP MODE, FAN SPEED PROTECTION FUNCTIONS EMERGENCY SWITCH TEST GUIDE MEMORY FUNCTIONS SUMMARIZE The Operation Modes
More informationTechnical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.
Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual LCAC/2016.1 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Part 1. General Information... 1 1. Nomenclature...
More informationService Manual. Air Conditional
Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30CM -3 - CONTENTS SPECIFICATION...
More informationCASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS
SERVICE MANUAL MULTI COMBI OUTDOOR AND INDOOR UNITS CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS (36k,42k) COMBINATION TABLE (unit: kw) MC-E18AI MC-E24AI MC-E28AI MC-E36AI 1 model 2 models 2 models
More informationPart 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45
Contents Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 The specifications, designs, and information in this book are subject to change without notice for product improvement.
More informationService Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1
Service Manual Room Air Conditioner Split Wall-Mounted Type Applies to: HSG-09CRN1 HSG-12CRN1 HSG-18CRN1 HSG-24CRN1 HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 NOTE: Please read this first before servicing
More informationOperating Functions Temperature Parameters
Operating Functions Temperature Parameters Room set temperature (T set) Room ambient temperature (T amb) Fundamental Functions After powered on, no matter when the compressor is started, the time interval
More informationContents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79
MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary
More information60Hz R410A ClimaMaster Tropical Rooftop Package Unit. Content. 1. Models List External Appearance Nomenclature...
0Hz R40A ClimaMaster Tropical Rooftop Package Unit MCAC-RTSM-20-0 Content. Models List... 2. External Appearance.... Nomenclature... 2 4. Feature & Benefit.... List of Function.... Specification... 8 7.
More informationWALL MOUNTED UNITS SDH W SDH W SDH W SDH W
WALL MOUNTED UNITS Technical Dossier WALL MOUNTED UNITS SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W 2010 1- CONTENTS 1- Contents... 2 2- Technical specifications... 3 3- Temperature by capacities...
More informationSERVICE MANUAL INVEST HEAT PUMP DC INVERTER SPLIT WALL-MOUNTED TYPE MSC-24/QD FP MSH-24/QD FP
SERVICE MANUAL INVEST HEAT PUMP DC INVERTER SPLIT WALL-MOUNTED TYPE MSC-24/QD FP MSH-24/QD FP V1.0 Nov, 2009 CONTENTS 1. Precaution... 1 1.1 Safety Precaution...1 1.2 Warning... 1 2. Function... 4 3. Dimension...
More informationR410 a. Air Conditioners. Residential and commercial. R410 a
Fresh Aireasy Breathe R410 a Air Conditioners Residential and commercial R410 a Airco Branded Products The Airco brand dates back to 1949 when it was first launched into the local market. This brand has
More informationService Manual & Installation Manual
GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR
More informationFree Stand Air Conditioner. Model: 42/38KFJ /38KFJ /38QFJ /38QFJ048833
Free Stand Air Conditioner Model: 42/38KFJ024733 42/38KFJ048833 42/38QFJ024733 42/38QFJ048833 Content CONTENT 1 Safety Precautions...1 1.1 Precaution... 1 1.2 Installation... 1 1.3 Caution... 1 1.4 Operational...
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationContent. The specifications, designs, and information in this book are subject to change without notice for product improvement.
MCAC-ATSM-2014-01 Content R410A Mini Split Chiller 50Hz 1. Model Names of Outdoor Units... 2 2. External Appearance... 2 3. menclature... 3 4. Features... 4 5. Descriptions of Standard Unit... 6 6. Specifications...
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationThe latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS
The latest innovation in cool 7 YEAR WARRANTY ON COMPRESSORS 1 YEAR WARRANTY ON PARTS Engineered to be both aesthetically pleasing and energy-efficient, Katashi air conditioning units bring the latest
More informationKSIM20912-H216 KSIM30912-H216 KSIM40912-H216
SERVICE MANUAL KLIMAIRE AIRCONDITIONER KSIM DC INVERTER MULTI TYPE KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 DC MULTI OUTDOOR UNITS CONTENTS 1. General information of Outdoor Units...3 2 Features...4
More informationSPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR
SPLIT TYPE AIR CONDITIONER SERVICE MANUAL WAS-09HSTD WINTAIR Type of contents 1. OPERATION RANGE 2. SPECIFICATION 3. INSTALLATION 4. REFRIGERANT FLOW DIAGRAM 5. ELECTRICAL DATA 6. CONTROL MODE 7. TROUBLE
More informationSubmittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18
Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18
More informationturn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES
turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners
More informationCalor Top 300D(S) Air-source Heat Pump Water Heater
v. 13.04 Calor Top 300D(S) Air-source Heat Pump Water Heater INSTALLATION & OWNER S MANUAL Applicable Models: :CALOR TOP 300D CALOR TOP 300D(S) Content 1. General Information... 4 1.1 Measurements... 4
More informationAir Conditioner CONTENTS
ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS
More informationSERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS
SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 7 3.1 Indoor
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationSERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.
SERVICE MANUAL Indoor unit Outdoor unit 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* INDEX PART1 GENERAL INFORMATION PART2 ELECTRICAL DIAGRAM PART3 TROUBLE
More informationDUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................
More informationHigh Wall SERVICE MANUAL. TLCA-TLHA 07 to 18 FSAAAR TLCA-07 / TLHA-07 TLCA-09 / TLHA-09 TLCA-12 / TLHA-12 TLCA-18 / TLHA-18 SM-TLCA-TLHA-07-18GB 06-08
High Wall TLCA-TLHA 07 to 18 FSAAAR SERVICE MANUAL TLCA-07 / TLHA-07 TLCA-09 / TLHA-09 TLCA-12 / TLHA-12 TLCA-18 / TLHA-18 SM-TLCA-TLHA-07-18GB 06-08 1. Precaution 1.1 Safety Precaution To prevent injury
More informationCEILING CONCEALED DUCT R410A 60HZ 3D INVERTER CONTROL 2017 TECHNICAL MANUAL
TM_DUCT_60R410A_3D INVERTER_US_S_NA_171113 CEILING CONCEALED DUCT R410A 60HZ 3D INVERTER CONTROL 2017 TECHNICAL MANUAL Table of Contents Page 1.... 4 1. Model Reference 2. General 3. Dimensional Drawings
More informationTAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT
More information1 Summary and features. Service Manual. Model QSVMI-09A QSVMI-12A QSVMI-18A
Summary and features Service Manual Model QSVMI-09A QSVMI-2A QSVMI-8A 2 Technical specifications Model QSVMI-09A QSVMI-2A QSVMI-8A Fan Motor Speed (r/min) (SH/H/M/L) 50/050/900/750 50/050/900/750 250/050/950/800
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationService Manual AIR CONDITIONER
Service Manual AIR CONDITIONER DC INVERTER MULTI TYPE This manual applies to models: High Wall Duct Cassette Console Universal CDU 42QHF009DS 42QHF012DS 42QHF018DS 42QSM009DS 42QSM012DS 42QSM018DS 42QTD009DS
More information1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...
FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN
More informationManual de Instrucciones Rooftop Serie CLIMA CREATOR 50Hz
Manual de Instrucciones Rooftop Serie CLIMA CREATOR Hz Lea atentamente todo este manual antes de utilizar su nuevo equipo de aire acondicionado. Modelos: BSRC _ HWN-R IMPRESO EN PAPEL ECOLÓGICO Contents.
More informationWired Controller XK60
Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice
More informationSubmittal Data Sheet
Submittal Data Sheet INDOOR UNIT OUTDOORE UNIT Model No. DIR-09AC17-DKI DIR-09AC17-DKO AS-09TR1SVDDA Type T1, INVERTER Performance Cooling Capacity Btu/h 9000 Heating Capacity Btu/h / Cooling Capacity
More informationTECHNICAL DATA & SERVICE MANUAL MTF94C5TAA
TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL
More information8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display
Wired remote controller (RBC-AMTE) Operation manual Parts Name of Remote Controller Display section In the display example, all indicators are displayed for the explanation. In reality only, the selected
More informationMidea R410A Domestic Pools & Spas Heat Pump Water Heater 50Hz A1 Series Technical Manual
Midea R410A Domestic Pools & Spas HPWH 50Hz Technical Manual MCAC-HTSM-201409 Midea R410A Domestic Pools & Spas Heat Pump Water Heater 50Hz A1 Series Technical Manual Applicable Model: (New CE safety directive)
More informationClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n
1311-R1211 GD Midea Refrigeration Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 D e a l e r i n f o r m a t i o n GD Midea Refrigeration
More informationAIR CONDITIONING SYSTEMS WALL MOUNTED UNIT
AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT SERVICE MANUAL MODELS: L4VI32-18/L4VO32-18 L4VI32-24/L4VO32-24 ENGLISH Table of Contents Part Ⅰ : Technical Information...1 1. Summary...1...2...3 2.2 Operation
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL
More informationSlim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump
0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More informationHIGH-EFFICIENCY DUCTLESS INDOOR COMFORT
UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers
More informationHi - Wall Split Systems 12K - 18K - 24K
R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic
More informationService Manual & Installation Manual
GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR C18 GE AIR C24 GE AIR C34 GE AIR C41 1 Introduction and Features Model Remarks
More informationTCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE031229 Models TAC-07CS/K TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CSC/K TAC-09CSC/K TAC-12CSC/K TAC-18CSC/K TAC-24CSC/K TAC-07CHS/K
More informationC&H NORDIC Commercial 4 SERVICE MANUAL
C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...
More informationHi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.
R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification
More informationChange for Life. Service Manual
Change for Life Service Manual Models: GWH09QB-K3DNA1G GWH09QB-K3DNA2G GWH09QB-K3DNA5G GWH09QB-K3DNB2G GWH09QB-K3DNB4G GWH09QB-K3DNB6G GWH12QC-K3DNA1G GWH12QC-K3DNA2G GWH12QC-K3DNA5G GWH12QC-K3DNB2G GWH12QC-K3DNB4G
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL
SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER SERVICE INSTRUCTION Models Indoor unit AU* G45LRLA AR* G45LMLA AR* G45LHTA AB* G45LRTA Outdoor unit AO* G45LETL AO* G54LETL
More informationLight Commercial SUPER INVERTER SERIES MULTI TYPE
Light Commercial SUPER INVERTER SERIES MULTI TYPE Service Manual 2017 CONTENTS 1. General information of Indoor Units... 1 2. Features... 2 3. Dimensions... 12 4. Service Space (unit: mm)... 19 5. Wiring
More informationPERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems
PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with
More informationSPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL
SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL 1. INTROUCTION Zone control is a two pieces fan coil thermostat available for Heat/Cool versions. Its application is for the duct type system
More informationCOLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A
COLDWAVE Portable Air Conditioner 12000 BTU/h 110V/1Ph/60Hz R410A Model MPPD-12CRN1 Features: 4 Speed Fan Ion Generator Sleep Mode Timer Auto/Cool/Dry Mode Swing Function Follow Me Temperature Sensor Swing
More informationR22 air-cooled modular chiller 50Hz unit. Content
Content 1.Nomenclature... 2 2.Product Schedule... 2. External Appearance... 4.Features... 4 5.Specification... 6 6.Dimension... 10 7.Refrigeration System Sketch Drawing... 14 8.Wiring Diagrams... 16 9.Electric
More informationNORTH AMERICAN HVAC PRODUCTS LTD. Tel: Fax: DC Inverter Single Zone Split Wall-Mounted Type
NORTH AMERICAN HVAC PRODUCTS LTD Tel: 604-4308496 Fax: 1-866-9034371 www.northamericanhvac.com Service Manual DC Inverter Single Zone Split Wall-Mounted Type Model Refrigerant type Power supply MSV1-18HRDN1-MQ0
More informationMono DC. VERTU MONO Split DC Inverter Air Conditioner SERVICE MANUAL MSV1-18HRDN1-MQ0W. Revision A: , Content updated.
VERTU MONO Split DC Inverter Air Conditioner SERVICE MANUAL Mono DC Revision A: 1305080001, Content updated. Model Numbers: 0 MSV1-09HRFN1-MT0W MSV1-12HRDN1-MQ0W MSV1-24HRDN1-MQ0W MSV1-12HRFN1- MT0W MSV1-18HRDN1-MQ0W
More informationThank you for selecting LENNOX air conditioners.
S Models: LI012CI-180P432 LI012CO-180P432 LI012HI-180P432 LI012HO-180P432 LI024CI-180P432 LI024CO-180P432 LI024HI-180P432 LI024HO-180P432 (Refrigerant R410A) Thank you for selecting LENNOX air conditioners.
More information6. DUCT TYPE AR 60FUAK, AR 60UUAK
R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor
More informationSERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC
Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.
More informationDUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.
DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085
More informationModels: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems
Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...
More information