FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR

Size: px
Start display at page:

Download "FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR"

Transcription

1

2 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR STADLER TR firewood hot water central heating boilers provide comfortable and energy saving heating. Such heating is enabled with integration of the new innovative technology in the field of control and modern production technology. s are constructed for burning all types of wood and reach efficiencies of over 91%. Constant growth of fossil fuel prices and the increased care for the environment make this boiler even more important. By using different types of wood, even of different humidity, these boilers allow you to reach perfect combustion conditions. Emitted flue gases are harmless to the natural balance. You should load the boiler with ½ m long firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 150 l and can be loaded with up to 50kg of hardwood logs. Connection to the power supply is very simple, as the boiler includes already prepared wiring with plug equipped cables. By purchasing our boiler, you meet all of the requirements to obtain your government's subsidy. Construction of the boiler incorporated the modern degassing combustion technology. The flame is vertically directed through the burner nozzle with the help of the controlled injection of the primary and secondary air. When the flame enters the combustion chamber, it swirls and in touch with the red-hot combustion chamber causes the remaining not-combusted wood gases to burn at temperatures of approx C. The control regulates the operation of the primary and secondary air step motors, thus supplying the combustion process with regulated quantities of air which enable the best combustion. The large panel shielded loading place protects the boiler from accumulation of tar and ensures long service life of the boiler. s can be loaded with firewood of up to 56 cm in length. The burner nozzle is made of chrome alloy which also significantly prolongs the service life of the boiler. 2 The boiler is included in the German BafA-List and therefore entitled to incentives. The fireproof clay combustion chamber is upgraded with the bottom made of high-temperature resistant concrete which guarantees complete combustion of wood gases. s are equipped with the Lambda probe, temperature sensor and continuously controlled electric motor of the fan. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

3 Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism allows good cleaning of the pipe register. With the help of the active combustion control equipped with the Lambda probe we provide products with many advantages: Simple and clear control, The lowest fireplace load, Longer service life of the boiler, Module control allows longer combustion phase, The best efficiency with the lowest emission values, Emitted flue gases are harmless to the environment, Constant control of the combustion process, Continuous fan control, Optional programmed ignition. The control allows simple control of the boiler. Fuel ignition can also be activated via your cell phone. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of Characteristics Unit TR 15 TR 20 TR 25 TR 30 TR 35 Nominal heat value kw Lowest boiler power kw efficiency at nominal power % 90, , , , ,01-92 Combustion efficiency % 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 Container volume l Loading door width and height mm 430 x x x x x 400 water quantity l Chimney connection mm Permissible operating pressure bar Required chimney draft Pa Max. flow temperature C weight kg Recommended accumulator size l height mm width mm depth mm Height of the chimney connection mm Delivery tube R 5/4 5/4 5/4 5/4 5/4 Return tube R 5/4 5/4 5/4 5/4 5/4 Supply discharge fitting R 3/4 3/4 3/4 3/4 3/4 Thermal protection device fitting R 3/4 3/4 3/4 3/4 3/4 Electrical connection 230 V +10/-15 %/50 Hz 160 W for operation; 400 W for ignition WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 3

4 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER LT Due to their wood gas combustion technology, Stadler LT firewood hot water central heating boilers enable energy saving heating. s are constructed for burning all types of wood and reach efficiencies of over 90%. They are completely made in Slovenia, thus showing high level of expertise. Development of the product brought such improvement that our company was granted with the national patent by the Slovenian Intellectual Property Office. These hot water boilers are constructed for burning of 56 cm, or 33 cm long firewood. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 125 dm3 and can be loaded with approx. 35 kg of firewood. The container should be loaded with firewood to its top limit, while taking care not to load the firewood too close to each other as this could cause jamming. Modern control with lambda probe enables you to burn different types of wood and to reach ideal combustion conditions with flue gases which are harmless to the natural balance. These boilers are equipped with modern fireplaces with hot combustion chambers made of temperature resistant ceramics. The hot combustion chamber allows swirling combustion of wood gases resulting in the combustion of all combustible substances in flue gases. Temperatures in the combustion chamber can reach over 1000 C, thus creating perfect combustion conditions. s can be installed into systems equipped with hot water reservoirs and room temperature control. The control regulates circulating pumps and motor driven three-way valves, thus achieving balanced consumption of the Characteristics Nominal heat value Unit kw LT LT 25 / LT reservoir's temperature layered water and longer heating time. Lowest boiler power kw 7 15 efficiency at nominal power % 90, ,3-91,2 Combustion efficiency % 92,1-93,1 93,3-94,5 Firewood container volume l Loading door width and height mm 400 x x 440 water quantity l Permissible operating pressure bar 3,0 3,0 Max. flow temperature C Upper chimney connection mm Required chimney draft Pa weight kg Recommended hot water reservoir size l height mm width mm depth mm Height of the chimney connection mm Delivery tube " 5/4 5/4 Return tube " 5/4 5/4 Water supply fitting " 1/2 1/2 Thermal protection device valve fitting " 3/4 3/4 Electrical connection 230 V +10/-15%/50Hz 160 W for operation; 400 W for ignition Our boiler is in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, EN 303-5). It is tested for pressure and water tightness and factory equipped with a thermal protection device, thus enabling the installation in closed heating systems. Permissible operating pressure of the boiler equals to 3 bars. All integral parts are made of tested materials of suitable quality and thickness. s are also equipped with the CE 0036 marking. Flue gas sensor 4 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

5 Construction of the boiler is patent protected, as its development included several innovations which significantly contributed to the improvement of the combustion processes. Our family of products equipped with the Lambda probe is one of the best in EU. CONTROL WITH LAMBDA PROBE The combustion process is regulated with a modern control via lambda probe and other temperature sensors. All data is promptly checked by the central control microprocessor which also performs corrective measures for the improvement of the combustion process. Control regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. The extremely efficient control also regulates the external heating system structures and allows control of operation via your cell phone. If the boiler is loaded with firewood, you can also start it with your cell phone. This novelty is appropriate especially when you are away from home longer than expected, or simply to make your home warm and comfortable at the time of your arrival USB - port for PC connection 2 - Graphical display 3 - Button (exit/reset) 4 - Button for the cleaning of the boiler, emissions measurement and safety thermostat test 5 - Button (down/reduction) 6 - Button (admission to menu/selection confirmation) 7 - Button (help) 8 - Button (forward/slope) 9 - Button (boiler commissioning /boiler charging) 10 - (Thermal fuse) 11 - Button (control ON and OFF) The combustion of firewood can be programmed via the ignition electrode. Preparation of firewood for the programmed ignition is simple and does not include special procedures. Fuel ignition can also be activated via your cell phone. Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism enables good cleaning of the pipe register. The combustion chamber made of high-temperature resistant ceramic ensures perfect combustion of wood gases. The reliable and robust fan equipped motor is continuously controlled and helps the fine-tuned control of the combustion process. Motor is protected with sheet metal cover which prevents all kinds of damage. The wiring of the boiler is made of temperature resistant cables and very clear. Power connection of the boiler can simply be performed at the terminal assembly on the external side of the boiler. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of The measurement certificate classifies the boiler on the list of subsidized boilers. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 5

6 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER GT STADLER GT boilers belong to a new generation of firewood hot water heating boilers. With their wood gasification technology they enable modern and energy saving heating. They are constructed to burn all types of firewood of up to 54 cm or 33cm in length. Their combustion efficiency reaches over 90%. themselfs are designed and produced in Slovenia. By naming the product range STADLER we wished to show that the production is still active and adapts to new combustion conditions and techniques. These boilers provide stable combustion processes enabled by the inovative construction and lambda probe. They achieve excellent combustion parameters which are characteristic for wood gasification boilers. Quality production, controlled combustion process and high efficiency of these boilers beat the competition of the lower priced boilers by far. By using different types of wood, it is possible to achieve good combustion conditions in the boiler. Firewood burns in the lower part, whilst the supplied primary air leads the flame and wood gases downwards into the combustion chamber. When flue gases come through the burner nozzle, they are blown with controlled supply of secondary air. Flue gases mixed with the flame and fresh air swirl in the combustion chamber, and in touch with the red-hot fireproof clay, burn with extreme temperatures. The control regulates the combustion process via lambda probe and the temperature sensor in the chimney and sensors installed in the boiler and the accumulator. It also regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. Controlled supply of the combustion air enables low values of emmissions in flue gases which are significantly lower than the law regulated ones. s are equipped with an insulated hot combustion chamber made of fireproof clay which quickly reaches high temperatures and enables good combustion of wood gases. The efficiency boilers reache over 90% which points out the top-class echievement. The hot combustion chamber enables the boiler to reach the optimal combustion process in only minutes. These boilers must be installed into systems equipped with hot water accumulators. We recommend the use of the heating system control because this is the only way to preserve different water layers in the hot water accumulator. Our boilers are in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, etc.). They are tested for pressure and water tightness, factory equipped with a thermal protection device and can be installed in closed heating systems. The permissible operating pressure of boilers equals to 3 bars. We recommend the use of firewood with humidity between 15 and 25% which is achieved by drying it outdoors for 2 years. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. The volume of the fireplace is 105 dm3 and can be loaded with approx. 30 kg of firewood. You should load the container with firewood to the top of the doors, while taking care not to load them too close to each other as this could cause jamming. The boiler is included in the German BafA-List and therefore entitled to incentives. Characteristics Unit GT 20 GT 25 GT 30 Nominal heat value kw Lowest boiler power kw kw efficiency at nominal power % efficiency at nominal power % Container volume l Loading door width and height mm 400 x 350 water quantity mm Chimney connection diameter mm Permissible operating pressure bar Required chimney draft Pa Max. flow temperature C weight kg Recommended a-ccumulator size l height mm width mm depth mm The depth of the boiler with open doors mm Depth of the loading area mm Height of the chimney connection mm Delivery tube R" 5/4 5/4 5/4 Return tube R" 5/4 5/4 5/4 Supply discharge fitting R" 1/2 1/2 1/2 Thermal protection device fitting R" 3/4 3/4 3/4 Electrical connection 230 V +10/-15%/50Hz 80 W for operation; 200 W for ignition 6 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

7 WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER PELET STAR Stadler PELET STAR hot water central heating boilers belong to a new generation of wood pellet boilers. They were designed by our company in cooperation with the Swedish company Ariterm. The BeQuem burner enabled the development of a completely automatic wood pellet boiler which guarantees reliable and safe operation with minimum cleaning and maintenance interventions. s are produced with the modern sheet metal treatment technique. Construction concepts provided the boiler with a touch of modern design, while respecting the ergonomic demands for the operation of the boiler. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN s are equipped with the CE 0036 marking and can also be installed in smaller rooms to provide comfortable and energy saving heating. The side of the boiler is equipped with the weekly wood pellet silo, whilst the large ash chamber allows longer intervals between cleaning. Construction of boilers allows easy access to all internal surfaces and hence easier cleaning and maintenance. We recommend you to install your central heating system with a hot water accumulator which allows optimum boiler operation with low energy consumption (low-energy constructions and transition periods). In case of bigger consumption, the hot water accumulator amortizes the current lower burner operation capacity. Special construction of the BeQuem wood pellet burner allows reliable operation and high level of safety. Wood pellet feeding is arranged with a double stoker system where the lower stoker feeds wood pellets into the lower part of the combustion chamber. With such wood pellet feeding the ash is pushed further and the combustion chamber automatically cleaned. Such feeding technique makes the burner appropriate even with wood pellets of weaker quality which can now often be found on the market. Fire safety is ensured with temperature sensors and the cell block. Ignition and control of the flame are controlled with a special sensor. Characteristics Unit PELET STAR Nominal heat value kw Lowest boiler power kw 5 20 efficiency at nominal power % 90, ,3-91 Combustion efficiency % 91,9-92,4 90,9-91,3 Wood pellet container volume l Cleaning door width and height mm 330 x x 250 water quantity l Permissible operating pressure bar 3,0 3 Max. flow temperature C Upper chimney connection mm Required chimney draft Pa weight kg Recommended hot water reservoir size l height mm Width of the boiler including the wood pellet container mm Depth of the boiler with the burner and the fan mm Height of the chimney connection mm Delivery tube 1 1 Return tube 1 1 Supply fitting 1/2 1/2 Electrical connection 230 V+10/-15 %/50Hz 80 W for operation; 200 W for ignition Combustion chamber made of high resistant alloy guarantees good combustion of wood pellets. Wood pellets are transported into the combustion chamber from below. Newly arrived pellets push the ash from the chamber, thus making cleaning of the chamber's burner unnecessary in the period of one heating season. Burner cleaning is simple. Unscrew it and simply remove from the boiler. LEGEND 1. Cell block 2. Transverse stoker 3. Fuel supply 4. Ignition electrode 5. Primary air pipe 6. Ignition pipe 7. Transport mechanism 8. Fan 9. Feeding stoker 10. Combustion chamber with wood pellets WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 7

8 WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER C 28 With the help of new innovative technologies wood pellet heating boilers enable comfortable, energy saving, and environment friendly heating. Firewood heating boilers represented the basis for the construction of wood pellet heating boilers. These boilers were constructed in cooperation with the HDG company and conform to the strictest regulations prescribed for such products. This claim is confirmed with the TÜV certificate. The boiler was reconstructed to burn wood pellets and now, in compliance with the prescribed flue gas emissions, enables combustion of wood pellets with efficiency of over 90%. s are equipped with an additional function which gives them advantage over other similar products. In case you run out of wood pellets or electric power, boilers also allow to burn firewood. Reorganization of the boiler to burn firewood is simple. Simply cover the opening of the burner and connect the draft control. The Swedish made burner allows integration with solid fuel boilers so that they serve as heat exchangers. Except for the environment friendly flue gases the burner operates in similar way as the oil burner. Ignition, operation and deactivation are automatic. Wood pellet feeding is performed with an extremely energy saving stoker which takes the pellets from the silo and feeds them into the burner. The burner can easily be set via the display. Combustion is regulated via the control installed on the burner. Burner operates in two levels in accordance with energy requirements. ADVANTAGES OF WOOD PELLET BURNING DEVICES construction is adapted to burn wood pellets, Enabled firewood burning, Completely automatic operation, Combustion with optimal efficiency, Good control enables energy saving operation, is made of 8 mm sheet metal, Efficiency of over 90%, No problems related to fuel preparation, Wood pellet supply similar to fuel oil supply, Care for the environment. Characteristics Unit C 28 PELET PX 22 GP 20 Nominal heat value kw 25 Lowest boiler power kw 10 efficiency at nominal power % 90,12 water quantity l 70 Chimney connection mm 130 Permissible operating pressure bar 3 Required draft Pa 13 Max. flow temperature C 95 weight kg 370 Recommended accumulator size l 1000 height mm 1070 width mm 797 Width of the boiler including the burner mm 1090 depth mm 660 Height of the chimney connection mm 780 Delivery tube 1 Return tube 1 Supply discharge fitting 1/2 Thermal protection device fittings 1/2 Electric connection 230 V/50 Hz 8 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

9 WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Stadler EKO PELET hot water central heating boilers were designed with combination of firewood boilers and Swedish made burners. In this way boilers with the BeQuem wood pellet burners became automated units for heating of living quarters. Unlike the use of fossil fuels, the use of local energy resources, such as wood pellets, is harmless to the environment and decreases heating costs. These wood pellet boilers are equipped with a control which allows completely automated operation of the boiler without constant regulation. They regulate the supply of pellets from the container and the combustion process. s are also equipped with a pellet ignition device and flame control. The burner activates automatically as soon as the sensor in the boiler detects fall of water temperature bellow the preset value, and deactivates as soon as this temperature is reached. The volume of the factory offered wood pellet container equals to 0.6 m3 which is enough for approx. 10 days of operation. Alternatively you can order a larger container with volume of 0,93 m3. Our company also offers elements for the construction of even larger wood pellet containers which can be assembled in your boiler room or the room next to it. These boilers can easily be rearranged into firewood heating boilers by unscrewing the flange screws, removing the burner and turning it into the position which does not interfere with the operation of the boiler. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Cleaning of the boiler is also very simple. Open the lower door and remove the ash collected in the drawer. From time to time it is also necessary to check if the combustion chamber is clean. In case you notice any slag residue, remove it adequately. We do not recommend you to disassemble the burner during cleaning, however if this is necessary please call our authorised repair service centre. After each rearrangement of the boiler for burning firewood, clean the fireplace of the boiler and the space under the grate. The construction of the burner is equipped with a display showing mode of operation and temperature. Under the display, there are some arrow keys which enable you to scroll along the simple menu. With the use of these keys you can set the operation of the burner or simply control its operation. Calculation of the required boiler power m 2 cm 0,30 Apartment x Living quarters x Heat loss size height coefficient Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of In case of simpler heating systems we recommend you to install a special pump. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C and then only emits the excess energy into the system. During the cool down phase, the pump and the three-way valve ensure that the water temperature in the boiler does not fall below 55 C, thus preventing the formation of condensate. If the system includes a hot water accumulator, the three-way mixing valve allows the accumulator to be filled. With the use of the water accumulator, better operation can be achieved, especially during transition periods when temperatures are not too low. model Wood pellet boiler capacity kw Firewood boiler capacity kw / 860 = Required boiler power Electric connection 240 V 50 Hz Power consumption 240 V 50 Hz Efficiency EKO PELET W 60 W 91,5 % EKO PELET W 90 W 90,7 % WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 9

10 WOOD PELLET AND FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Kompakt EKO pelet Kompakt wood pellet hot water heating boilers are equipped with wood pellet containers located above the boiler where the domestic water heater is generally installed. These boilers are appropriate for installation in smaller spaces where there is desire for comfortable and energy saving heating. s are produced left or right oriented. They can easily be rearranged into firewood heating boilers by unscrewing the flange screws connecting the burner and the boiler, removing the burner and turning it into the position which does not interfere with the operation of the boiler and its safe loading. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Fasten the line of the draft regulator to the primary air flap of the lower door. Remove the safety barrier and the rectifier from the boiler. After you finish the above procedure, the boiler is rearranged to use firewood. CHARACTERISTICS OF FIREWOOD BOILERS: Stadler EKO hot water central heating boilers are constructed to burn 33 cm long firewood (logs are to be loaded transversely) and 56 cm long firewood (logs are to be loaded longitudinally to the boiler). They are intended for operation in the 90/70 C mode. The new way of flue gas conduction improves combustion processes during the burning of firewood. Loading doors enable loading of large logs. Constructions of boilers are produced in accordance with regulations DIN 4751 B1.1, DIN 4702 and EN s are also equipped with the CE 0036 marking. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must ensure drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your wood pellets or firewood in a downwards direction, thus prolonging the combustion time of a single load. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces enables easy cleaning and maintenance. Burner position during firewood burning. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of model Eko Pelet Kompakt Firewood power kw Wood pellet capacity kw Delivery tube R Pellet silo for Kompakt l Self-standing pellet silo for Eko Pelet l water quantity l Weight EKO s kg L B H-Eko Kompakt DIMENSIONS (mm) Hs-Eko Pelet D F G d / / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

11 HOT WATER CENTRAL HEATING ACCUMULATORS MODEL: AT Hot water accumulators represent intermediate central heating elements and are used in modern heating systems. They are used for accumulation of the excess thermal energy produced by the boiler and for evenly regulated supply of energy to different consumers. Hot water accumulators are indispensable in systems with installed firewood, wood pellet, or wood chip heating boilers. Firewood heating boilers do not allow the complete control of power without significant interruption of the combustion process. Firewood combustion cycle brings excess thermal energy which consumers cannot use at that moment therefore it is conducted to the hot water accumulator. After the fuel has burnt and the heating elements cooled down, the automatic control takes care for transfer of hot water from the accumulator to heating elements. Our production programme includes hot water accumulators of various sizes: 500, 750, 1000, 1250, 1500, 1800, 2000, and 3000l. Accumulators are equipped with fittings for connection of heating circles, sensors and thermometers. The number of used fittings depends on the complexity of the planned heating system prescribed by the manufacturer at the time of sale of the product or by other professional subjects. Model / values Unit AT 500 AT 750 AT 1000 AT 1250 AT 1500 AT 1800 AT 2000 AT 3000 Volume l D1+diameter including insulation mm D-diameter mm H - height mm H angled height mm Total weight kg Permissible operating pressure bar Max. operating temperature C Take care that the angled height is not greater than the room height, as this would prevent the installation of the accumulator. D1 Our production programme includes several standard volume hot water accumulator types: AT AT B AT BI AT B2I AT B3I AT I AT 2I AT 3I AT 3I PB WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 11

12 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO in EKOs Stadler EKO heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). Construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6cm. The above stated means, that it is possible to load the boiler with firewood of up to 40 cm and 56 cm in length. s EKO are to be loaded with 33 cm long firewood, whilst boilers EKO are to be loaded with 50 cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of flue gas conduction improves combustion processes during firewood burning. Large loading doors allow easy loading of firewood into the fireplace which can be loaded with large quantities of firewood, therefore we recommend you to burn your firewood in a downwards direction, thus prolonging the combustion time of a single load. The heater temperature control is performed by setting the desired temperature on the control cabinet which represents an integral part of the boiler equipment. Equipment of EKO boilers also includes quality enamelled domestic water heaters. They are equipped with an Mg-anode which serves for enamel protection. s with EKOs marking (s - solo) are not equipped with hot water heaters, but can be additionally bought and installed. Construction of boilers is made with 3D-designing in accordance with all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN s are equipped with the CE 0036 marking. and heater are tested for pressure and water tightness. The permissible operating pressure of the boiler equals to 3 bars. For the purpose of achieving high product quality, all integral parts of the boiler are made of quality materials. s are also factory equipped with thermal protection devices. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must enable drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your fuel in a downwards direction. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces allows easy cleaning and maintenance. SCOPE OF DELIVERY: with insulation, Thermal protection device, Domestic water heater for EKO boilers, Thermometer, Cleaning kit. Models EKOs 12 and 14 are not delivered with the domestic water heater Firewood Fireplace Delivery Heater Required Weight Weight model power size tube water water draft EKO s EKO DIMENSIONS (mm) EKO quantity quantity EKO-s kw dm 3 R l l Pa kg kg L B Eko s Eko D F G d / / / / / / / / / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

13 WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER HS HS boilers were developed on the basis of long years of experience in the field of development and production of heating equipment. s are intended for burning all types of wood. They are distinguished by long inclined loading doors and a large combustion chamber which allow simple use and loading of the boiler with large quantities of fuel. Chimney connection is located at the back side of the boiler. s are equipped with a combustion chamber and a pipe register with turbulators for better heat exchange. Chimney must be constructed in accordance with the SCHIEDEL table for solid fuel boilers. Draft must comply with the values stated in the table for the selected model of the boiler. Construction of the fireplace and the perfect insulation guarantee maximum fuel efficiency. s are to be loaded transversally with firewood of up to 36 cm in length. Fuel burns in the lower side part of the boiler. Installation of the grate in the fireplace and installation of the flap on the secondary air door significantly improve the combustion process. The installed return water preheater and the water-cooled grate prevent the low-temperature corrosion. Easy access to all internal surfaces allows easy cleaning and maintenance. By purchasing additional burner control and special burner doors, your boiler can be rearranged to burn fuel oil. For domestic water heating you must connect the boiler with a self-standing water heater, because the construction of the boiler does not enable you upgrade boiler with a heater. s are distinguished by quality production as they are made with laser cutting of metal sheet and robot welding. s are also factory equipped with a thermal protection device. SCOPE OF DELIVERY with lining and insulation Thermometer Cleaning kit LEGEND 1. Fireplace loaded with firewood 2. Flue pipes 3. Exhaust of flue gases with a flap 4. Water-cooled grate 5. Ash space, drawer 6. Pipe register cleaning opening 7. Return water preheating 8. Return tube 9. Delivery tube 10. Panelling with insulation 11. Loading doors 12. Doors for cleaning and relighting the fire 13. Primary air flap 14. Safety tube 15. safety flow, supply, discharge 16. draft control fitting R ¾ 17. connection thermometer sensor R ½ 18. Protection door vertical grate 19. Fireproof clay 20. Mixing channel 21. Secondary air rotating flap 22. Thermal protection device Model HS Loading Firewood door power dimensions kw Fireplace size dm 3 Chimney connection Ø water quantity l Required draft Pa Weight kg Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of Delivery Heater and return coonnection tube R R DIMENSIONS (mm) L B H L1 H1 A D x / x / x / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 13

14 WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 28 Stadler Central series boilers are constructed fur burning firewood. Combustion in the lower side part and the vertical 4-draft conduction of flue gases enable good transmission of flue gas heat to the heated water. Combustion in the lower side part classifies the boiler in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. Fireplaces are adapted to standard firewood lengths. Fireplace of the Central 28 boiler is adapted to be loaded with 33 cm long firewood. Special channel for the conduction of combustion air to individual combustion zones enables good combustion of fuel. The Central 28 boiler is equipped with a special fireproof clay combustion chamber where the previously not combusted flue gases in the fireplace are burnt. s also come equipped with a combustion grate made of grey cast iron which can be moved, thus enabling you to remove the ashes from the grate during the operation of the boiler. Additionally, the boilers are equipped with a thermal protection device and draft control. Vertically installed cleaning openings enable easy access to internal vertical channels. Construction of boilers respected all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN s are equipped with the CE 0036 marking. s are also factory equipped with a thermal protection device. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Good efficiency and minimum environmental nuisance, Automated draft control enables slow-burning, Moving grate enables cleaning during operation, Single load is sufficient for several hours of burning, The boiler is adapted to burn firewood and certified for German market. The use of certified materials provides long service life of the boiler. L SCOPE OF DELIVERY with lining Thermometer Draft control Cleaning kit C28 B1 128 B C 24 C 28C 24 C 28 H3 H3 H3 H2 H1 H1 H2 H H1 B1 B B L1B1 L1 B L1 B1 model CENTRAL Heat power kw Fireplace size dm 3 water quantity l Chimney Chimney Connection Ø Ø mm mm Required draft Pa Outflow inflow R Weight kg DIMENSIONS (mm) L L 1 B B 1 H H 1 H 2 H WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

15 WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 17 IN 23 Storey boilers are intended for installation and use in non-basement residential houses and residential apartment blocks with no central heating and no chance of classic boiler room installation. Combustion in the lower side part classifies these boilers in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. s are extremely energy saving, thus making the fuel consumption of a single heating season very low. Dimensions and visual appearance are adapted for installation in fitted kitchens. The central heating installation should be executed in a way that enables horizontal connection to the heating system (at the side of the boiler). Such installation enables the boiler to be levelled with the edge of the kitchen working counter. Pipes routed vertically behind the boiler will cause the boiler to be unaligned with the fitted kitchen. s are equipped with a three-way chimney connection and vertical chimney connection with a cover. They are appropriate for burning of dry firewood of up to 25 cm in length. s should be connected to an Ø 118 mm diameter chimney (23 kw boilers to Ø 128 mm). Chimney draft should equal to 20 Pa. We recommend you to measure the chimney prior to the installation of the boiler. In case of low quality chimneys, such chimneys should be arranged to enable optimal operation of the boiler. All boilers are equipped with a thermal protection device, whilst new models come with a flexible loading cover enabling easier fuel loading. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Installed cooking plate allows reheating of your dishes, Room with the installed boiler does not require additional radiators, Good efficiency and minimal environmental nuisance, Automated draft control enables slow-burning, Moving grate enables grate cleaning during operation of the boiler, Single load is sufficient for several hours of burning, Use of certified materials provides long service life of the boiler. SCOPE OF DELIVERY C17 C23 with lining Thermometer Draft control Cleaning kit Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of " 1/2" 3/4" 35 3/4" 70 1" 1/2" 850 C 23 C 17 C 23, C 17 H " 40 3/4" /4" 1" /2" model CENTRAL Heat power kw Power (water) kw Power (environment) kw Container dm 3 Burner water quantity l Chimney Connection Ø mm Required draft Pa Outflow inflow R Weight cca kg H mm WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 15

16 DUAL FIREPLACE FIREWOOD AND FUEL OIL CENTRAL HEATING BOILERS MODEL: STADLER TOBI Stadler TOBI central heating boilers are constructed as extremely energy saving boilers due to the installation of fuel oil and firewood boilers in a single construction. Both boilers use a single water reservoir, but completely separated fireplaces. Such design enables automatic rearrangement from burning of one type of fuel to another which cannot be achieved with combined boilers. s are basically intended for burning firewood in the 90/70 C operating mode. The fuel oil part of the boiler activates automatically after all of the fuel from the firewood fireplace has been used and the temperature dropped under the preset value. The fuel oil part of the boiler does not activate if the firewood fireplace is full and the preset temperature is reached. In case you deactivate the automatic system, these boilers only operate by burning firewood. A more modern construction concept classifies these boilers among the new generation of eco-friendly products as they operate in a similar way as hybrid cars. The firewood fireplace is equipped with modern burning in the lower side part of the boiler which enables controlled long burning process lasting even over 3 ½ h. The fireplace allows you to burn 33 cm long firewood. s are equipped with a return water preheating system and a cast iron grate which improves firewood combustion processes. Loading doors allow loading of large pieces of firewood. The special fireplace constructed for burning fuel oil is equipped with a hot combustion chamber and a turbulator in the third draft. Its design enables top-class efficiency of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The fuel oil part of the boiler is equipped with the SELTRON control. These boilers cannot be upgrades with domestic water heaters. Domestic water heaters can be installed as separated units which are then connected to the boiler. Ba purchasing the domestic water heater additionally, it is possible to control the temperature in the domestic water heater with the help of a pump. panelling is enamelled in the RAL 3000 or RAL 2004 colour combination. Our boilers are in compliance with all regulations regarding safety at work. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN 303-5, and is equipped with the CE 0036 marking. s are also equipped with a thermal protection device. The central heating system must compulsory include one of the system for lifting the return water as this is the only way to use the boiler with lower powers. If the boiler is not connected with the system for lifting return water the boiler condensates and causes poor combustion. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C, and emits only the excess energy into the system. At the same time it prevents the return water with temperatures lower than 55 C to enter the boiler, thus preventing the condensation. If the system includes a hot water accumulator, the three-way mixing valve enables the accumulator to be filled. With the use of the hot water accumulator, better operation of the burning device can be achieved, especially during the transition periods when temperatures are not too low, but still demand heating. model TOBI Power (fuel oil) kw Power (wood) kw Fireplace size dm 3 water quantity l Required draft Pa Weight kg Chimney Connection (fuel oil) Ø Chimney Connection (wood) Ø width mm height mm Required door width to enter the boiler with panelling into the room Required door width to enter the boiler without panelling into the room Efficiency (fuel oil) ,2 81, ,4 81,5 % Efficiency (wood) % 16 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

17 FIREWOOD AND FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER EKOs and RLs These devices include two separate boilers. The basic boiler is the firewood boiler onto which the fuel oil boiler or gas oiler is installed. The firewood boiler is reinforced with two holders which enable safe installation of the fuel oil or gas boiler. Each boiler represents the best solution for itself as it is in compliance with all ecology standards. The boiler can additionally be upgraded with a separate domestic water heater, whilst the heating control takes place via the external control. Stadler EKOs heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). The construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6 cm, thus enabling you to load the boiler with firewood of up to 40 or 56 cm in length. s EKOs 25 are to be loaded with 33cm long firewood, whilst boilers EKOs are to be loaded with 50cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of conduction of flue gases improves the combustion processes during firewood burning. Large loading doors enable easy loading of firewood into the fireplace. s can be loaded with large quantities of firewood, therefore we recommend you to burn your fuel in a downwards direction, thus prolonging the combustion time of a single load. L1 B1 H1 d G1 D1 50 H L B d F1 G F D Special Stadler RLs fuel oil and gas boilers are produced with welded frameworks made of larger dimensioned materials. fireplaces are equipped with a hot reversible chamber and turbulators within the pipes which allow combustion with efficiency of over 93%. Flue gas exhaust emissions are lower than required by law, especially NOx, CO, whilst the flue gas temperatures in the chimney do not reach 180 C. s are in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). The basic equipment includes also the control cabinet for the regulation of the burner operation. Power Fireplace Required Weight Delivery L B H D F G d model les size water draft EKOs tube quantity EKOs kw dm 3 mm mm mm mm mm mm mm l Pa kg R / / / /4 Power Required Weight Delivery L 1 B 1 H 1 D 1 F 1 G 1 d model (fuel oil) water draft MVs tube quantity mm mm mm mm mm mm mm RLs kw l Pa kg R /4" /4" WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 17

18 FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER RL and RLs Special welded Stadler RL boilers are constructed for burning fuel oil or gas and are made of the thickest certified sheet metals. fireplaces are equipped with hot reversible chambers and turbulators within the pipes which allow top-class combustion efficiencies of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The boiler is in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). RL marked boilers are equipped with vacuum enamelled heaters for preparation of domestic hot water. Domestic hot water temperature can be controlled with the help of the pump. RLs boilers are delivered without the heater for preparation of domestic hot water. These boilers are distinguished by good 50 mm thick insulation. The panelling of the boiler is protected with powder enamelling. The basic equipment also includes the control cabinet for the control of burner operation. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of SCOPE OF DELIVERY RL RLs with lining and insulation control Water heater control If the delivery includes the base of the boiler it is necessary to consider its height of 270 mm. Hot combustion chamber and turbulators Cleaning brush L B As optional equipment you can install an electric heater (2 kw) for domestic water heating during the summer. We recommend you to purchase the additional heater at the time of your order, as the subsequent installation is more expensive and complex. Hs G F D H Power Water Flow Weight Weight Chimney model water heater return RL RLs DIMENSIONS (mm) RLs, RL kw quantity l l R kg kg Ø mm L B H Hs D F G / / / / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

19 FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Euro HDG Euro boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all of the prescribed values. Contraction and production of the boiler are in accordance with all safety regulations. These boilers were granted the German innovation award and are equipped with the TÜV quality marking. Large fuel loading space significantly increases fuel reloading intervals. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection with the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. Combustion takes place in the lower side part of the boiler on the grate which allows wide selection of fuels. Along with the special combustion chamber, the robust and innovatively constructed burner nozzle provides swirling mixing of flue gases which ensures optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. Grates are massive and equipped with a practical cleaning opening. The loading shaft is made of 10 mm thick quality steel sheet. Pneumatic cylinders facilitate opening of shaft doors. The system bolt of the loading shaft cover enables safe loading. The spacious conical loading shaft can be filled with firewood or bulk material. If you select the right size of the device, you will be able to get the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include a hot water accumulator as such reservoir combined with the boiler control guarantees environment friendly combustion. The hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of the accumulator depends on customer s demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. Combination of the firewood boiler equipped with the hot water accumulator and the solar energy device meets the demands of the modern heating system. Lambda control enables very low emission values, high efficiency and low fuel consumption. The adjustable primary and secundary air motors provide accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process. Predtok 1 1/ Lambda Control constantly measures and displays the following parameters: Quantity of the remaining oxygen in flue gases, Temperature of flue gases for uniform efficiency, Temperature of the heating boiler and water reservoir, Lifting of the temeperature of the return water. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of Model Heat power Povratni tok 11/ objemka za praznjenje/ polnjenje 1/2 783 Vnosna mera Območje odpiranja For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure Lowest Loading Loading space Chimney Operating Required Max. flow boiler space width and water connection pressure draft weight temperature power volume depth quantity Ø C kw kw l mm l mm Bar Pa kg HDG Euro x HDG Euro x HDG Euro x Recommended accumulator size l WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 19

20 FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Turbotec LEGEND 1. Loading space (340 l), 2. Cleaning opening, 3. Lambda probe and the flue gas sensor, 4. Fan, 5. Loading from above optional and with additional payment, 6. HDG lambda control, 7. Loading doors - front, 8. Primary and secondary air control, 9. Cleaning opening Thermal protection device sensor 1 / 2 VL 1 1 / 4 varnostni toplotni izmenjevalec 1 / 2 RL 1 1 / 4 Praznjenje 1 / HDG Turbotec boilers are firewood heating boilers with large loading space of up to 340 l. they are intended tu burn firewood with lengths of up to 1 m, thus prolonging the interval between loadings. In case you have fine fuel at your disposal, you can also additionally order the upper boiler loading doors. Turbotec boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all prescribed values. Construction and production of the boiler are in accordance with all safety regulations. They are ideal for use in the craft industry, agriculture and forestry, and are equipped with the TÜV quality label granted by a German institution. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection to the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. The robust and innovative constructed nozzle provides good combustion. The interior of the combustion chamber is shielded with fireproof concrete. Swirling of flue gases in the combustion chamber provides optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. s are made of quality steel sheet. Primary and secondary air servomotors deliver the necessary air directly in the combustion zone. Primary air takes care for constant performance of the boiler, whilst the secondary air takes care for the lowest flue gas emission values. If you select the right size of the device, you will be able to obtain the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include the hot water accumulator as such accumulators combined with the boiler control guarantee environment friendly combustion. Installation of the hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of accumulators depends on customer's demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. HDG Turbotec boilers are equipped with HDG lambda control 1 which ensures very low emission values, high efficiency and low fuel consumption. Adjustable primary and secondary air motors deliver accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process Power Loading Loading Loading Chimney Required Operating Max. flow Model space volume space depth space width water quantity connection Ø draft pressure temperature weight kw l mm mm l mm Pa Bar C kg HDG Turbotec 50 L HDG Turbotec 60 L WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

21 HDG WOOD CHIP AND WOOD PELLET HEATING SYSTEMS MODEL: HDG Compact These boilers are appropriate for burning wood pellets and wood chips with humidity of up to 45%. s can also burn Class 6 and 7 fuels. The compact and favourable priced versions are appropriate for use in households, agriculture, craft industry and public institutions, basically everywhere where a reliable and economic operation is required. Constant power is provided by the automatic technology of angled or movable grates. s are equipped with automatic ignition via the hot air fan. Two large external ash collectors make operation and maintenance easy. s are distinguished by low emission values and optimum efficiency of over 90%. The reliable fuel loading technology and the fire extinguishing device provide absolutely safe operation. Cell block is especially accurately manufactured and takes care for proper loading. Vertical surfaces of the heat exchanger provide better heat transfer. In emergency situations boilers can also burn firewood. HDG Compact electronic control device of the boiler takes care for good combustion technology and is a product of our development programme. It can also be upgraded for control of different heating systems. All actual conditions of the operating device are shown on the display. Fuel loading takes place directly on combustion grates. Fuel supply and primary and secondary air can be adjusted independently. Even in case of bigger shares of non-combustible materials, the power stays constant due to the technology of angled grates. After reaching a certain loading level, the fuel ignites with the help of hot air. Automatic ignition increases the device control comfort. Device operates with optimum emission values. You should prevent long lasting smouldering during the time of ember preservation, thus preventing the contamination of heat exchanger and chimney surfaces. In combination with the fire extinguishing equipment, loading of the boiler via the patented cell block and feeding stoker guarantees perfectly safe operation. With the help of the cell block, the combustion chamber is completely separated from the silo and the transport unit and represents patented protection from the return fire. The next advantage lies in cutting of large firewood by the cell block into smaller pieces, thus creating ideal combustion conditions. The circular skimming device for takeover of wood mass from the silo is appropriate for simple, unproblematic takeover of wood chips, wood pellets, wood shavings, sawdust and wood briquettes from the silo. Maximum stoker length is 6 m (max. weight of fuel = 250 kg/m3). The takeover device can be installed also in larger containers, provided that they do not require complete emptying. Two pretightened joint levers are equipped with rotating spring feathers which rotate and skim the wood mass onto the stoker. Material takeover takes place along the transverse and open transport stoker. In case of square and round containers (6 m diameter) emptying takes place with the transverse stoker. The loading system can be installed in different positions in 180 radius according to the option of the silo connection. These systems are described in details in technical brochures. Our experts will make a special offer with technical solutions which meet the customer's demands for each individual device. For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure. Power Power Combustion Combusted air water Operating Required Flow Model area gas temperature flow quantity quantity pressure draft temperature weight kw kw C g/s l Bar Pa C kg HDG Compact , , HDG Compact , HDG Compact , HDG Compact , HDG Compact , HDG Compact , HDG Compact , HDG Compact , WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 21

22 FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER Z doors open in the left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating systems regulation, control equipment of the most renowned foreign manufacturers is used. Stadler Z heating boilers are Slovenian products with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards and are produced in standard versions for operation with 4 bars of overpressure. For higher pressures (>10 bar), modified construction is used. You can choose between 90/70 C and 110/90 C operating modes. The ideal construction and the flame pipe type of flue gas conduction provide optimum combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with railings intended for cleaning and supply and with the entrance and exit ladder. B SCOPE OF DELIVERY with left or right opening doors fixation panel Electric switch cabinet Lacquered pannelings with insulation Z Flue Model Heat Flue Safety Supply power water pipe return tubes discharge weight B D E F H H quantity 1 I K L L 1 L 2 Ø cca Z kw l mm DN DN R kg WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

23 LOW PRESSURE STEAM BOILERS MODEL: STADLER ZP Stadler ZP low pressure steam boilers are used for production of steam with overpressure of 0.5 bars. They are Slovenian made with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards. The ideal construction and the flame pipe type of flue gas conduction provide optimal combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with a ladder and walkable platform with railings. doors open in left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating system regulation, control equipment of the most renowned foreign manufacturers is used. SCOPE OF DELIVERY Low pressure steam boiler with left and right opening doors Two-colour lacquered panneling with insulation Base plate for the installation of the burner Operation and safety pressostats (3 pcs) Level switch Inspection glass (2 pcs) Pressure gauge Pressostat installation fitting ZP Model Power Steam Steam Safety Condense DN Flue quantity takeover tubes tubes pipe weight A B C D H H1 H2 H3 H4 L L1 Ø cca ZP kw kg/h DN1 DN2 DN3 R mm kg x x WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 23

24 GAS AND FUEL OIL HOT WATER BOILERS MODEL: STADLER ZV In these times, when the environmentally aware part of the world tries to lower the emissions of greenhouse gases into the environment, it is very important that the fossil fuels heating systems operate as efficiently as possible, with perfect combustion, and low fuel consumption. Our company already several years ago decided to actively contribute to the development of such heating devices with no impact to the environment. On the basis of 40 years of tradition in the field of boiler production and intensive investments into development, our company produced a new family of hot water boilers named STADLER ZV. These boilers are constructed on the triple draft principle with low Nox emissions. Due to the low load of the combustion chamber ( 1,2 MW/m3) and the conduction of flue gases through the pipe register, these boilers provide optimum combustion with top-class efficiency. s are made in accordance with Directive 97/23/CE PED and the Slovenian SIST EN12953 standard regarding gas or fuel oil burning. s are also equipped with a substantially dimensioned heat part. At the time of dimensioning of flame pipes, flue pipe packages and the water part, special attention was given to thermodynamic compliance and fast transfer of temperature to the water. s are also equipped with large volume water parts appropriate for optimum temperature control in different operating conditions. Inspection openings for entrance into the water part are easily accessible and allow easy access. s are well insulated and installed on a support frame. The operating overpressure is adapted to customer's demands. Our company produces boilers intended for pressures of 6-16 bars with the maximum operating mode of up to 160 C depending on the order or the investor's temperature mode. Minimum operating mode equals to 60 C. The external boiler fitting must provide protection of the hot water boiler against too low temperatures of the return tube. Equipment of the boiler can also include the system for protection against condensation. Good boiler insulation prevents heat loss into rooms and enables stable thermal operation. s are insulated with two layers of 60 mm thick Type ZV Heat power water quantity Transport weight Operating weight water side flue side Flue side volume width lengt height kw l 6 bar 16 bar 6 bar 16 bar mbar mbar m 3 B L H ,3 1, ,7 1, ,2 2, , ,6 4, ,8 5, ,7 5, ,5 6, ,7 8, ,5 8, ,5 12, ,2 14, ,5 16, ,5 19, , WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

25 LMF10 ALUR lamella insulation which makes total insulation 120 mm thick. Construction of the boiler enables to connect the burner to a special flange, which is to be installed on the neck of the combustion chamber. Combined with»low NOx«burners, our boilers achieve very low emission values (NOx < 100 mg/kwh). These boilers are equipped with double doors at the front side which open in the left and right direction, thus enabling easy access to pipe exchangers. Back side of boilers includes inspection opening of the combustion chamber, opening for the control of the flame and the flue cabinet. The flue cabinet is equipped with inspection covers and the pipe with a valve for condensate discharge. The flue cabinet can also be installed with a motorised flue flap for prevention of ingress of cool air into the boiler when it operates in idle mode. Above the flue cabinet, it is possible to install a heater for reduction of flue gas temperature which additionally increases the efficiency of the device and lowers the fuel costs. Such installation can lower the fuel consumption for up to 10%. The equipment of the heater can also include the system for protection against condensation. Lower fuel consumption enables additional decrease of CO2 emissions and lesser impact on the environment. Low resistance at flue gas and water sides, low radiation loss, and simple maintenance and cleaning represent additional advantages of these boilers. equipment includes safety equipment in accordance with SIST EN12953 standard, including the intermediate flange piece for installation of the safety and control equipment. The quality control of Weishaupt burners enables top-class control of the combustion process. Our company upgrades the Weishaupt control cabinets in such way, that they also allow the control of peripheral systems in the boiler room. Output signals of the boiler and control cabinet enable the regulation and control of the operation via the CNS. If the boiler room contains several boilers, they can be controlled via the cascade regulation with diagnostics of the device operation. s are equipped with the platform and a ladder. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation, operation control and maintenance operations. Our company manages all inquiries in a project way and adapts boilers to customer's demands. At the investor's demand, the company can take care for complete delivery of the equipment with all installations. In the name of the investor, our company can also elaborate all necessary documents for the preparation and execution of the project, and the technical acceptance. Modern 3D planned ZV boiler 's cross section shows the construction design which provides combustion with low flue gas emissions. Substantially dimensioned material cross sections do not burden the materials and prolong the service life. s are distinguished by the modern laser and CNC technology machining, whilst joint welding is performed with the help of powder welding processes. Welding is strictly controlled by the internal control and outside institutions. Type ZV Torch Burner Flue Flue Flow, Flow, Flow, Safety Safety Safety Water Bleeding diameter connection height connection connection height return PN 16 return PN 16 return PN 16 valve 6 bar PN 16 valve 8 bar PN 16 valve 16 bar PN 16 discharge Ø H1 Ø H2 20 C 30 C 40 C DN DN DN PN 40 PN WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 25

26 WOOD RESIDUE, WOOD CHIP AND WOOD PELLET HEATING SYSTEMS BIOFLAMM Biomass is becoming more and more important economic factor as it enables energy independence and discontinuation of fossil fuel use which represent excessive impact on the environment. Due to the increasing prices of fossil fuels and financial country incentives for biomass equipment, investment into this equipment become very profitable in short-term. Our company has been producing boilers and biomass equipment for almost 30 years and has developed and still develops a wide range of products. Equipment is technologically adapted so it can be installed practically in every room, even in smaller boiler rooms which were planned for fuel oil boilers. The company strives for improvement of products, especially regarding the combustion technique, with solutions for combustion of chemically compromised wood residues and with the use of wide range of granulation and moisture. s are adapted also for burning wood pellets, thus allowing the use of biomass boilers even in cities, industrial facilities and other settlements. BIOFLAMM HEATING SYSTEMS MODEL: VE/SREB s are produced with the installed reactor with the step grate. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. In the first draft, boilers with integrated burner are shielded with fireproof clay A 40 or A 60, depending on the fuel the device is planned for. Construction of the boiler allows to burn wood residue with humidity of up to 45%. s are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms and railings, intended for cleaning and supply, and with entrance and exit ladders. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. At the flue gas exhaust it is necessary to install a fan and a flue gas deduster, thus achieving dedusting of up to 80 mg/m3. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. The entire device is controlled by the Lambdamatik micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 2 MW, temperatures 140 C and operating pressure 4.5 bars). model Power kw water quantity l height mm width mm lengt mm Safety flow Flow return Flue connection mm Weight kg V DN 50 DN V DN 50 DN V DN 60 DN V DN 65 DN V6 / DN 65 DN V DN 65 DN V DN 65 DN V DN 65 DN V DN 80 DN V DN 80 DN V DN 80 DN V DN 80 DN V DN 100 DN V DN 100 DN WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

27 Model Heating power kw power kw Weight kg BIOFLAMM HEATING SYSTEMS MODEL: TRB/VA This heating device comprises the pre-fireplace reactor TRB and the VA boiler. The combination of these two components is used everywhere where the combustion conditions are difficult due to the higher humidity or due to the problematic fuel. Bioflamm multi draft VA boilers are used as heat exchangers and places for flue gas burn down. s are equipped with two horizontal drafts and three vertical drafts routed through the pipe packages. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. In especially tough operating conditions boilers are shielded with quality fireproof clay in the first draft. Large dimensioned drafts and vertical pipe packages provide this heat exchanger with low temperature flue gases and enable high efficiency. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). The automatic Bioflamm TRB pre-fireplaces with movable grates and automatic deashing enable the combustion of very problematic fuels. Reactors are constructed as a water-cooled pipe cage construction. The frame of the burner is shielded with quality fireproof clay A 40 or A 60, depending on the fuel the device is planned for. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Grates are installed next to each other, are simple, can be individually replaced, and form several movable grate layers. In case of extra humid, ash rich, or slag forming fuels, the Bioflamm degassing reactors with special air injection systems improve the combustion with their controlled combustion air fans. The primary air fan regulates the degassing process on the grate, whilst the secondary air fan enables combustion during the degassing of the formed flue gases. Separation from the fireplace and the boiler enables fast control in accordance with DIN 4751 Part 2. Reactors are produced in two construction versions; TRB N for humid fuels and TRB T for dry fuels. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). In the past years, the company also developed an extra version of reactors marked TRB LK for connection of grain dryers or dryers of the sawdust accumulated during wood pellet production. Reactors are made of double-walled steel sheet frame where the air is directed into individual combustion zones. On the internal side, reactors are shielded with fireproof clay, whilst their external side is substantially insulated to prevent heat radiation into the environment. Grate movements and combustion air injection are similar to those of the basic version. The entire TRB/VA device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Water quantity l Flow return DN Lengt mm Width mm Height mm Center of the flame pipe mm Diameter of the flame pipe mm Height to the stoker mm TR-B 5N TR-B 6N TR-B 7N TR-B 8N TR-B 9N TR-B 10N TR-B 11N TR-B 12N TR-B 13N TR-B 14N TR-B 15N WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 27

28 BIOFLAMM HEATING SYSTEMS MODEL: TREB These heating devices were developed with the integration of transverse TRB reactors and VE boilers. This version is very good in coping with problems of combustion of all types of problematic fuels and allows installation in smaller boiler rooms. s allow the combustion of wood mass with humidity of up to 50% and wood mass with chemical substances which accumulate in the wood industry and could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are also appropriate for burning wood pellets and are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The external side of the boiler is equipped with a special system of channels for the supply of primary air under the grates. This feature improves the formation of wood gas as well as the combustion process. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply, and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. Production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The entire device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m 3. s are factory shielded with fireproof clay A 60, which is resistant to high temperatures released during combustion. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. Model Heat power kw water quantity l height mm width mm lengt mm Safety flow Flow Flue connection mm TREB DN 40 DN TREB DN 50 DN TREB DN 50 DN TREB DN 50 DN TREB DN 50 DN TREB DN 65 DN TREB DN 65 DN TREB DN 65 DN TREB DN 65 DN TREB DN 65 DN TREB DN 80 DN Weight kg 28 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

29 BIOFLAMM HEATING SYSTEMS MODEL: SRF-RK These boilers are appropriate for burning relatively dry wood chips with humidity of up to W 45, and wood pellets. They include a fireplace and a heat exchanger. Fireplaces with the movable step grate represent the basic part of these boilers. Fireplaces are shielded with quality fireproof clay. Construction of the boiler enables burning relatively clean wood residue and wood pellets. s are equipped with a large combustion chamber which enables good combustion. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and enable high efficiency. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are shielded with fireproof clay A 40 or A 60, depending on the used fuel and operating conditions. In case the boilers burn dry fuel or wood pellets, they are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionaly install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Smaller boilers are delivered welded as a whole, whilst, larger boilers come in two parts which are later assembled together in your boiler room. Assembly in the boiler room is especially welcome in case of low passages where the transport into the boiler room is less favourable. Type Bioflamm TRF-RK Power (flame) kw Useful boiler power kw Weight kg water quantity l Flow Return DN Safety flow DN Lengt mm Width mm Height mm SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK SRF RK WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 29

30 BIOFLAMM KURILNI SISTEMI MODEL: TRF-RK These boilers are appropriate for use where the biomass humidity cannot be controlled or where the humidity cannot be dried out and therefore remains very high. In the first and second draft, boilers are shielded with quality fireproof clay. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Construction allows to burn inferior and problematic humid wood residues which could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are equipped with a large combustion chamber with the first inversion of hot flue gases over the fuel where the first phase of fuel drying begins. The large quantity of fireproof clay radiates the temperature on the fuel which moves along the grate, thus drying it additionally. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. The well-dimensioned second draft serves also for deposition of large particles of floating ash. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and high efficiency. s are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is constantly controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. Type Power Useful Weight water Flow Safety Lengt Width Height Standard scope of microprocessing control delivery includes Bioflamm (flame) boiler power quantity Return flow the system for calling of 6 telephone numbers in case of TRF-RK kw kw kg l DN DN mm mm mm standstill of any component of the device. With additional TRF-RK payment it is possible to supply customers with a control TRF-RK for remote regulation and inspection of the combustion TRF-RK system and for the control of peripheral units. At the flue TRF-RK gas exhaust of the boiler it is necessary to install a flue gas TRF-RK deduster. TRF-RK Where the demands are very strict it is necessary to TRF-RK additionally install electric or fabric filters. Fabric TRF-RK filters enable cleaning of dust particles of up to TRF-RK mg/m 3. Smaller boilers are delivered welded as a whole, TRF-RK whilst larger boilers come in two parts which are later TRF-RK assembled together in your boiler room. Assembly in the TRF-RK boiler room is especially welcome in case of low passages TRF-RK where the transport of the boiler is less favourable. 30 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

31 DEVICE CONTROL Controls with the Lambda probe Lambdamatika and Optimatika+ are installed in Rital cabinets which include all control elements for the entire system, continuous motor drives, protection of drive units, and the device for calling of 6 telephone numbers. On special order they can also be installed with modems for connection with the remote control. The cabinet is equipped with the main switch (depending on the supply power of electric motors) and the emergency switch. Doors of the cabinet are equipped with the microprocessor with a display and a keyboard for direct access into the combustion parameter setting program. Use of the program and the input of desired data is simple as the program allows scrolling with cursor keys and includes simple commands. The programme is made as a multi-level programme device operator level and repair or fine-tune expert level. VISUALIZATION The communication package for remote control of data and for the visualization of operation is used for control when the operator is out of the boiler room. The connection is established with the help of the modem and internet, or directly via the cable in case of small distances. In case of the cable connection, the visualization works trouble-free for 24 h, but demands an amplifier in case of distances greater than 200 m. Long-term connection via your telephone will cause disturbances during monitoring of current values due to the signal strength fluctuation. Significant data about device operation and reports of disturbances can be followed on the PC display. This way enables the operator-supervisor the access to all required data, which is why he can quickly react in cases of device malfunctioning. On the basis of these data, the supervisor makes corrective measures and adapts the operation to desired parameters. If the supervisor is unable to repair the malfunctioning he must immediately contact the manufacturer's service team which will take care for it with no major problems. With the permission of the investor, the manufacturer's service team can enter into the communication system. The visualization allows access to different levels of operation, depending on the data to be checked. All levels enable formation of excel charts and analyses of operation in individual time periods. Because this is a complex heating device, we recommend the operator to plan adequate maintenance interventions on the basis of number of hours of operation. COMPANY PRESENTATION OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z Besides this trademark we are also present in the wood biomass market with Bioflamm and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on top-class laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 31

32 Valvasorjeva 73, 2000 Maribor Tel.: , Fax: Industrial store: Tel.: , Fax: wvterm@wvterm.si art a design - Kramberger & Uran

33 WV term d.o.o. Adress: Predstavitev: STADLER TVT TRADE MARKS: STADLER TVT Bioflamm COMPANY PRESENTATION REFERENCES 1 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

34 WV term d.o.o. STADLER TVT PRESENTATION OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z Besides this trademark we are also present in the wood biomass market with Bioflamm and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on topclass laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors. Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

35 WV term d.o.o. COMPANY IN PICTURES STADLER TVT COMPANY DATA Value Yearly turnover 4,8 mio Number of employees 68 Export 43% IExport in EU 38% Domestic market 57% Turnover with products 81% Turnover with services 19% Employees with high education 8 Employees with middle education 20 Qualified workers 28 Trained workers 12 Technology and development 7 Research and development group 3 ISO 9001 modul B and D Service for quality Own boiler testing room yes yes up to 50 kw Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

36 WV term d.o.o. STADLER TVT MASCHINERY EQUIPMENT EQUIPMENT/MASCHINERY Laser cutting maschine 3000 V Laser cutting maschine 3000 V Plasma cutting maschine 2 x 2000 V Welding robot VALUE table 2 x 4 m table 1,5 x 3 m table 2 x 8 m 2 x table 0,7 ton Welding automat 2 CNC bending maschine CNC bending maschine CNC curving maschine 250 ton 200 ton d=8 mm Curving maschine d=14 mm CNC maschine for cutting tubes and sticks 400 mm Maschines for forming the tubes 3 Hidraulic bending maschine Shears for cuttin up to thickness 250 ton 12 mm Boring maschine up to 100 mm 4 Fres maschine 1 Lathmaschine 400 mm L=3 m 2 Puls welding appliance 10 Enamel finish 1 Crane up to 30 tons 2 Crane up to 5 tons 4 Forkmaschineup to 4 tons 4 Trucks up to 5 tons 2 Service vehicles 5 Production surface m 2 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

37 WV term REFERENCES d.o.o. STADLER TVT WVterm has s TŰV certificate AD- Merkblatt HP 0 and certificate TRD 201, tis helps the company to produce tipicaly certified boilers and vessels under higher pressure. The company has become the certificate in accordance to Standard ISO 9001 modul B and modul D, which emphasizes the qualifications of the company for the production of boilers. In accordance with the slovene legislation WVterm has the certificate that it is qualified for boiler welding and production of high pressure vessels. Tha Company ha salso golden sign for the product quality SQ. We have many patents and trade marks protected at the Bureau of industrial property. We produce over pieces of boilers yearly, the capacity varries from 12 kw to kw, among them there are over 100 pieces of boilers with capacity from 200 kw to kw. Lately we encrease the production of boilers for biomass. We V zadnjem času se močneje širi proizvodnja kotlov na biomaso, kar velja tudi za slovenski trg. Through our domestic partner in Germany we cover the markets in all European countries. Our biggest devices from 3 MV up to 6 MV work in Germany, Netherlands, Italy and Russia. The greatest meaning in our economical position has our export, that is why we strive after high business and high quality. Our Sale to former Yugoslav markets is higher from year to year. The trade mark STADLER is on this markets still appreciated. Graf 1 REALIZACIJA PO DRŽAVAH SLOVENIJA 39% NEMČIJA 42% NEMČIJA AVSTRIJA BOSNA SRBIJA HRVAŠKA 0% SRBIJA 2% BOSNA 4% AVSTRIJA 13% HRVAŠKA SLOVENIJA The company exports over 60 % of its yearly production, 55 % is exported to european Union. Special Refference is Projekting and control of Instalation in Hospital in Jakutsk Russia, area over m 2. Projekt was made throug Biro 71 Ljubljana in the Yaer Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

38 WV term d.o.o. REFERENCE LIST OF DEVICES ON BIOMASS FUEL STADLER TVT Type of device Fuel Kapacity in kw Buyer State SR-EB 4 / V4 E pellets 200 PLANINSKI MUZEJ MOJSTRANA SLOVENIJA SR-EB 4 / V4 E wood chip 200 ŽG LJUBLJANA SLOVENIJA SR-EB 5 / V5 E wood chip 300 DETA SLOVENIJA SR-EB 5 / V5 E wood chip 300 TRGOCEV SLOVENIJA SD 5/FLUID Eragon dry sawdust 300 PABLES SLOVENIJA SR-EB 6 / V6 E wood chip 400 KAGER HIŠE SLOVENIJA SR-EB 6 / V6 E pellets 400 DIJAŠKI DOM DRAVA SLOVENIJA SR-EB 6 / V6 E wood chip 400 ŠPORTNI CENTER DRAŠ SLOVENIJA TR-EB 6 / V6 E wood chip 400 COMTRON IN SLOVENIJA TR-EB 6 / V6 E wood chip 400 OŠ PUCONCI SLOVENIJA SR-EB 7 / V7 E wood chip 500 SIRIUS SLOVENIJA VA 7/ FLUID Eragon dry sawdust 600 MIZARSTVO MAKOVEC SLOVENIJA SR-EB 6 / V6 E parni 0,5 bar wood chip 600 / 800 kg pare/ h TOPP SLOVENIJA SR-EB 8 / V8 A wood chip 750 PRELOG SLOVENIJA SR-B8 SW / V8-E wood chip 750 ECOM RUŠE SLOVENIJA TR B8 (N) / V8 A wood chip 750 SOBERNHEIM NEMČIJA SR-EB 8 / V8 E peleti 750 VITEZ BiH SR-EB 8 / V8 A peleti 2 x 750 BRČKO BiH SRF-RKP 750 parni kotel 4,0 bar wood chip 750 / 960 kg pare/ h SIRARNA BOHINJ SLOVENIJA VA 10/ FLUID Eragon dry sawdust JOŠT HOTEL SLOVENIJA SRF-RK 860 wood chip 860 KEMIJSKA ŠOLA RUŠE SLOVENIJA TRF-RK 1100 wood chip OSL REWE NEMČIJA TRF-RK 1100; SRF-RK 520 wood chip WVterm SLOVENIJA TR EB 10 / V10 E wood chip SESLACH NEMČIJA VA 11/ FLUID Eragon dry sawdust CELES SLOVENIJA VA 11/ FLUID Eragon dry sawdust RIKO HIŠE SLOVENIJA TREB 11,/ SR-EB 7 / V7 E Mitraka wood chip AHA EMI SLOVENIJA SR-B11 SW / V11 A 6 bar wood chip KREUTH NEMČIJA TRB 11 / V11 A wood chip GG NOVO MESTO SLOVENIJA TRF-RK 1250 wood chip PROFILES SLOVENIJA SR-EB 11 / V11 E wood chip DELNICE HRVAŠKA SR-EB 12 / V12 E wood chip SCHLESWAG AVSTRIJA SR-EB 12 / V12 E wood chip REMA / TORKIN BELGIJA TR B12 (N) / V 12A wood chip RAALTE NIZOZEMSKA TRF-RK 1500 wood chip KOZJE daljinsko ogrevanje SLOVENIJA SR-EB 13 / V13 E wood chip NAHOMA ROHA FINSKA SR-EB 13 / V13 E wood chip MILANO ITALIJA SR-EB 13 / V13 E wood chip REFRONTOLO ITALIJA SR-EB 13 / V13 E wood chip PIOBESI TORINESE ITALIJA SR-EB 13/ V13 E wood chip ETHON VEL. BRITANIJA TREB 13 Eragon 4,5 bar wood chip KOPITARNA SLOVENIJA VA 13/ FLUID Eragon 4,5 bar dry sawdust TUS KOSI SLOVENIJA TRB 14 / V14 A wood chip EFFETTI ITALIJA TRB 14 / V14 A wood chip GORENJE MARLES SLOVENIJA TRF-RK 2000 Mitraka wood chip TERME OLIMJA SLOVENIJA TRF-RKP 2000 parni kotel 6 bar wood chip 2.000/3000 kg pare/ h VITIVA SLOVENIJA TRB LK 15 wood chip SUŠILNICA BIOMASE TRGOVIR BiH TRB 15 / V 15A wood chip ILMES SLOVENIJA TRB 15/V 15A wood chip ČARDAK daljinsko ogrevanje SLOVENIJA TRB 15/V 15A wood chip WARENDORF NEMČIJA TRB 30 /V 30A wood chip NIEUWEWEG NEMČIJA TRB /V 30A wood chip TAMAI DI BRUNERA ITALIJA TRB 35/V 35A wood chip BATTAGLIA ITALIJA TR EB 15 + TR EB 12 wood chip Bolnica MINDEN NEMČIJA TRB 15/V 15+ V 11/TRB 11 wood chip INLES RIBNICA SLOVENIJA TRB 25 wood chip SUŠILNICA BIOMASE TRGOVIR BiH TRB 30 / V30 A wood chip FIS VITEZ BiH TRB 30 wood chip GRAFENEK SUŠILNICA ŽIT AVSTRIJA TRB LK 30 wood chip 2x3.000 OZL SUŠILNICA ŽIT UKRAJINA TRB LK 30 wood chip SUŠILNICA ŽIT SLOVENIJA TRB 45 wood chip MENEGOLO ITALIJA TRB 60 / V 60 wood chip BAUTEX RUSIJA Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

39 WV term d.o.o. STADLER TVT COMPLIENCE WITH THE REGULATIONS FOR BIOMASS BOIKERS Stack gas emissions The design of the boiler control "Bioflamm-Lambdamatika or Optimatik +" by the lambda probe and multiciklon ensure that the device will operate with high efficiency, emission of flue gases will be in accordance with the requirements (Official Gazette 34/07, Official Gazette of RS 73/94, 105 / 00, 84/02 and amedments of the Official Gazette of RS 51/98). emitted substance MEV v mg/m3 pri 11% O2 vol. total dust 1 Heat loss from the flue gases 175 Total dust v odvisnosti od moči kotla carbon monoxide (CO) at rated power 150 Nitrogen oxides (NOx) expressed as NO2 250 Sulphur oxides (SOx), expressed as SO Organic compounds expressed as total organic carbon 10 (TOC) Konstruktional implementation Safety Technical derivation of Bioflamm combustion plant according to TRD 414 section 1.6 and 1.7: Devices that are licensed and are operating from a TÜV-tested, are equipped with guards metering of electrical drives with self-control, safety buffer. For closed heating installations according to DIN 4751 and TRD 702 device meets the prescribed implementation of district heating system, which has proven parts. The two-step temperature controller and Safety temperature limiter according to DIN 3440 The safety valve according to TRD 721 and sensor min. and max. pressure Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

40 WV term d.o.o. STADLER TVT STUDENT HOME DRAVA MARIBOR 8 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

41 WV term d.o.o. STADLER TVT STUDENT HOME DRAVA MARIBOR Technical Data Type of device SREB6/VE6 Kapacity of boiler 400 kw Type of fuel pellets Fuel moisture max. 12% Emission of dust in smoke gases 60 mg/m 3 Transport of the fuel Worm convayor Pellets silo 90 m 3 Consumption of fuel out of the tank with movable base Hidravlic cylinder 160 mm Hot water acumulator 2x3000 l Year of installation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

42 WV term d.o.o. STADLER TVT BOILER HOUSE GORENJE MARLES Maribor 10 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

43 WV term d.o.o. STADLER TVT BOILER HOUSE GORENJE MARLES Maribor Technical Data Type of device TRB14/VA14 Kapacity of boiler kw Type of fuel Wood chips Fuel moisture max. 45 % Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transport of the fuel conveyor The fuel storage room 180 m 3 Consumption of fuel out of the tank with movable base Hidravlic cylinder 2x200 mm Hot water acumulator l Year of installation 2009 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

44 WV term d.o.o. ALP MUSEUM MOJSTRANA STADLER TVT 12 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

45 WV term d.o.o. STADLER TVT ALP MUSEUM MOJSTRANA Technical Data Type of device SREB4/VE4 Kapacity of boiler 200 kw Type of fuel pellets Fuel moisture max. 12% Emission of dust in smoke gases 60 mg/m 3 Transport of the fuel z polži The fuel storage room 50m 3 Consumption of fuel out of the tank spring cover Hidravlic cylinder Hot water acumulator 2x3000 l Year of installation 2010 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

46 WV term d.o.o. DISTRICT HEATING ČRNOMELJ - ČARDAK STADLER TVT 14 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

47 WV term d.o.o. STADLER TVT DISTRICT HEATING ČRNOMELJ - ČARDAK Technical data Type of device TRB15/VA15 Kapacity of the boiler kw Type of fuel Wood chips Fuel moisture max. 45% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transport of the fuel conveyor The fuel storage room 250 m 3 Consumption of fuel out of the tank with movable base Hidravlic cylinder Hot water acumulator 4 x 200 mm l Year of installation 2007 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

48 WV term d.o.o. STADLER TVT STEAM BOILER HOUSE VITIVA MARKOVCI 16 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

49 WV term d.o.o. STADLER TVT STEAM BOILER HOUSE VITIVA MARKOVCI Techical data Type of device TRF RKP 2000 Kapacity of boiler kw Kapacity of steam 3,500 kg/h Steam operating pressure 8 bar Emission of dust in smoke gases 20 mg/m 3 Fuel type Wood chips Fuel moisture max. 45% Chip size G 50 Transportation of fuel conveyor The fuel storage room 2x250 m 3 Consumption of fuel out of the tank with movable base Hidraulic cylinder 2 x 3 x 200 mm Year of installation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

50 WV term d.o.o. STADLER TVT CEREAL DRYING HOUSE ŠKAPER VANEČA 18 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

51 WV term d.o.o. STADLER TVT CEREAL DRYING HOUSE VANEČA Technical data Type of the device TRB LK 30 Kapacity of boiler kw Emission of dust in smoke gases 80 mg/m 3 Kapacity of drying 15 ton/h Temperature of drying 120 C Vertikal heat exchanger kw Air flow through the exchanger m 3 /h Type of fuel Wooden chips Flue moisture max. 45% Chip size G 50 Transportation of the fuel conveyor The fuel storage room 190 m 3 Consumption of fuel out of the tank Hidraulic cylinder Reserve fuel Movable base 3 x 200 mm Natural gas Year of installation 2013 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

52 WV term d.o.o. STADLER TVT PRIMARY SCHOOL PUCONCI 20 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

53 WV term d.o.o. STADLER TVT PRIMARY SCHOOL PUCONCI Technical data Type of the device TRB6/V6E Kapacity of the boiler 400 kw Fuel type Wooden chips Fuel moisture max. 45% Chip size G 30 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel conveyor The fuel storage room 120 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder 2 x 200 mm Year of installation 2013 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

54 WV term d.o.o. BOILER HOUSE OLIMIA SPA STADLER TVT 22 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

55 WV term d.o.o. STADLER TVT BOILER HOUSE OLIMIA SPA Tehnični podatki Type of the device TRF RK 2000 Kapacity of the boiler kw Fuel type Wooden chips Fuel moisture max. 60% Chip size G 50 Emission of dust in smoke gases 20 mg/m 3 Transportation of fuel conveyor The fuel storage room 300 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm l Year of the instalation 2011 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

56 WV term d.o.o. STADLER TVT DISTRICT HEATING KOZJE 24 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

57 WV term d.o.o. STADLER TVT DISTRICT HEATING KOZJE Technical data Type of the device TRF RK 1500 Kapacity of the boiler kw Fuel type Wooden chips Fuel moisture max. 60% Chip size G 50 Emission of dust in smoke gases 20 mg/m 3 Transportation of fuel conveyor The fuel storage room 350 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm l Year of the instalation Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

58 WV term d.o.o. STADLER TVT BOILER HOUSE FIS VITEZ BOSNA 26 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

59 WV term d.o.o. STADLER TVT BOILER HOUSE FIS VITEZ BOSNA Technical data Type of the device TRB 30/VA 30 Kapacity of the boiler kw Fuel type lesni sekanci Fuel moisture max. 80% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel transportni trak The fuel storage room 450 m 3 Consumption of fuel out of the tank pomična dna Hidraulic cylinder Warm water acumulator 3 x 200 mm Year of the instalation 2011 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

60 WV term d.o.o. STADLER TVT BOILER HOUSE FIS BRČKO BOSNA 28 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

61 WV term d.o.o. STADLER TVT BOILER HOUSE FIS BRČKO BOSNA Technical data Type of the device SREB 8/VE8 Kapacity of the boiler 2x750 kw Fuel type pellets Fuel moisture max. 10% Chip size Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel conveyor The fuel storage room 250 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 2 x 200 mm Year of the instalation 2010 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

62 WV term d.o.o. STADLER TVT BOILER HOUSE GG NOVO MESTO 30 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

63 WV term d.o.o. STADLER TVT BOILER HOUSE GG NOVO MESTO Technical data Type of the device TRB 12/VA 12 Kapacity of the boiler kw Fuel type lesni sekanci Fuel moisture max. 80% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel transportni trak The fuel storage room 450 m 3 Consumption of fuel out of the tank pomična dna Hidraulic cylinder Warm water acumulator 3 x 200 mm l Year of the instalation Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

64 WV term d.o.o. STADLER TVT GRAMMAR SCHOOL RUŠE 32 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

65 WV term d.o.o. STADLER TVT GRAMMAR SCHOOL RUŠE Technical data Type of the device STRF RK 860 Kapacity of the boiler 860 kw Fuel type Wooden chips Fuel moisture max. 40% Chip size G 50 Emission of dust in smoke gases 60 mg/m 3 Transportation of fuel transportni polz The fuel storage room 210 m 3 Consumption of fuel out of the tank krožno zajemalo Hidraulic cylinder Warm water acumulator l Year of the instalation 2013 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

66 WV term d.o.o. STADLER TVT AHA EMMI SLOVENSKA BISTRICA 34 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

67 WV term d.o.o. STADLER TVT AHA EMMI SLOVENSKA BISTRICA Technical data Type of the device Kapacity of the boiler TREB 11+ SREB /VE kw Fuel type Wooden chips Fuel moisture max. 45% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel conveyor The fuel storage room 310 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm l Year of the instalation 2009 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

68 WV term d.o.o. STADLER TVT PRIMARY SCHOOL DELNICE CROATIA 36 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

69 WV term d.o.o. STADLER TVT PRIMARY SCHOOL DELNICE CROATIA Technical data Type of the device Kapacity of the boiler SREB 12/VE kw Fuel type pellets Fuel moisture max. 10% Chip size G 50 Emission of dust in smoke gases 60 mg/m 3 Transportation of fuel transportni polz The fuel storage room 190 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 2 x 200 mm l Year of the instalation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

70 WV term d.o.o. STADLER TVT BOILER HOUSE PROFILES RAZDRTO 38 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

71 WV term d.o.o. STADLER TVT BOILER HOUSE PROFILES RAZDRTO Technical data Type of the device TRF RK 1250 Kapacity of the boiler kw Fuel type Wood chips Fuel moisture max. 60% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel auger The fuel storage room 280 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm Year of the instalation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

72 WV term d.o.o. STADLER TVT BOILER HOUSE PLANINA KRANJ Technical data Type of the device Kapacity of the boiler Hot warter ZV kw Fuel type zemeljski plin Temperature regime 130/60 C CNS for system Attached to cogeneration Year of installation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/ , fax:(386) 02/ , Industrijska prodajalna: tel.:(386)02/ fax:(386)02/

73

74 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR STADLER TR firewood hot water central heating boilers provide comfortable and energy saving heating. Such heating is enabled with integration of the new innovative technology in the field of control and modern production technology. s are constructed for burning all types of wood and reach efficiencies of over 91%. Constant growth of fossil fuel prices and the increased care for the environment make this boiler even more important. By using different types of wood, even of different humidity, these boilers allow you to reach perfect combustion conditions. Emitted flue gases are harmless to the natural balance. You should load the boiler with ½ m long firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 150 l and can be loaded with up to 50kg of hardwood logs. Connection to the power supply is very simple, as the boiler includes already prepared wiring with plug equipped cables. By purchasing our boiler, you meet all of the requirements to obtain your government's subsidy. Construction of the boiler incorporated the modern degassing combustion technology. The flame is vertically directed through the burner nozzle with the help of the controlled injection of the primary and secondary air. When the flame enters the combustion chamber, it swirls and in touch with the red-hot combustion chamber causes the remaining not-combusted wood gases to burn at temperatures of approx C. The control regulates the operation of the primary and secondary air step motors, thus supplying the combustion process with regulated quantities of air which enable the best combustion. The large panel shielded loading place protects the boiler from accumulation of tar and ensures long service life of the boiler. s can be loaded with firewood of up to 56 cm in length. The burner nozzle is made of chrome alloy which also significantly prolongs the service life of the boiler. 2 The fireproof clay combustion chamber is upgraded with the bottom made of high-temperature resistant concrete which guarantees complete combustion of wood gases. s are equipped with the Lambda probe, temperature sensor and continuously controlled electric motor of the fan. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

75 Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism allows good cleaning of the pipe register. With the help of the active combustion control equipped with the Lambda probe we provide products with many advantages: Simple and clear control, The lowest fireplace load, Longer service life of the boiler, Module control allows longer combustion phase, The best efficiency with the lowest emission values, Emitted flue gases are harmless to the environment, Constant control of the combustion process, Continuous fan control, Optional programmed ignition. The control allows simple control of the boiler. Fuel ignition can also be activated via your cell phone. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of Characteristics Unit TR 15 TR 20 TR 25 TR 30 TR 35 Nominal heat value kw Lowest boiler power kw efficiency at nominal power % 90, , , , ,01-92 Combustion efficiency % 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 Container volume l Loading door width and height mm 430 x x x x x 400 water quantity l Chimney connection mm Permissible operating pressure bar Required chimney draft Pa Max. flow temperature C weight kg Recommended accumulator size l height mm width mm depth mm Height of the chimney connection mm Delivery tube R 5/4 5/4 5/4 5/4 5/4 Return tube R 5/4 5/4 5/4 5/4 5/4 Supply discharge fitting R 3/4 3/4 3/4 3/4 3/4 Thermal protection device fitting R 3/4 3/4 3/4 3/4 3/4 Electrical connection 230 V +10/-15 %/50 Hz 160 W for operation; 400 W for ignition WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 3

76 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER LT Due to their wood gas combustion technology, Stadler LT firewood hot water central heating boilers enable energy saving heating. s are constructed for burning all types of wood and reach efficiencies of over 90%. They are completely made in Slovenia, thus showing high level of expertise. Development of the product brought such improvement that our company was granted with the national patent by the Slovenian Intellectual Property Office. These hot water boilers are constructed for for burning of 56 cm, or 33 cm long firewood. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 130 dm3 and can be loaded with approx. 35 kg of firewood. The container should be loaded with firewood to its top limit, while taking care not to load the firewood too close to each other as this could cause jamming. Modern control enables you to burn different types of wood and to reach ideal combustion conditions with flue gases which are harmless to the natural balance. These boilers are equipped with modern fireplaces with hot combustion chambers made of temperature resistant ceramics. The hot combustion chamber allows swirling combustion of wood gases resulting in the combustion of all combustible substances in flue gases. Temperatures in the combustion chamber can reach over 1000 C, thus creating perfect combustion conditions. s can be installed into systems equipped with hot water reservoirs and room temperature control. The control regulates circulating pumps and motor driven three-way Characteristics Nominal heat value Unit kw LT LT valves, thus achieving balanced consumption of the reservoir's temperature layered water and longer heating time. Lowest boiler power kw 7 15 efficiency at nominal power % 90, ,3-91,2 Combustion efficiency % 92,1-93,1 93,3-94,5 Firewood container volume l Loading door width and height mm 400 x x 400 water quantity l Permissible operating pressure bar 3,0 3,0 Max. flow temperature C Upper chimney connection mm Required chimney draft Pa weight kg Recommended hot water reservoir size l height mm width mm depth mm Height of the chimney connection mm Delivery tube " 5/4 5/4 Return tube " 5/4 5/4 Water supply fitting " 1/2 1/2 Thermal protection device valve fitting " 1/2 1/2 Electrical connection 230 V +10/-15%/50Hz 160 W for operation; 400 W for ignition Our boiler is in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, EN 303-5). It is tested for pressure and water tightness and factory equipped with a thermal protection device, thus enabling the installation in closed heating systems. Permissible operating pressure of the boiler equals to 3 bars. All integral parts are made of tested materials of suitable quality and thickness. s are also equipped with the CE 0036 marking. Flue gas sensor 4 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

77 Construction of the boiler is patent protected, as its development included several innovations which significantly contributed to the improvement of the combustion processes. Our family of products equipped with the Lambda probe is one of the best in EU. CONTROL The combustion process is regulated with a modern control via temperature probes. All data is promptly checked by the central control microprocessor which also performs corrective measures for the improvement of the combustion process. Control regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. The extremely efficient control also regulates the external heating system structures and allows control of operation via your cell phone. If the boiler is loaded with firewood, you can also start it with your cell phone. This novelty is appropriate especially when you are away from home longer than expected, or simply to make your home warm and comfortable at the time of your arrival. Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism enables good cleaning of the pipe register. Activation of the boiler is simple. This button activates the boiler. These, in buttons allow you to access individual menus and to fine-tune the operation of the boiler according to customer's demands. The combustion of firewood can be programmed via the ignition electrode. Preparation of firewood for the programmed ignition is simple and does not include special procedures. The control allows you to regulate your boiler via your cell phone and to ignite the fuel simply by calling the boiler control. The combustion chamber made of high-temperature resistant concrete ensures perfect combustion of wood gases. The reliable and robust fan equipped motor is continuously controlled and helps the fine-tuned control of the combustion process. Motor is protected with sheet metal cover which prevents all kinds of damage. The wiring of the boiler is made of temperature resistant cables and very clear. Power connection of the boiler can simply be performed at the terminal assembly on the external side of the boiler. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of The measurement certificate classifies the boiler on the list of subsidized boilers. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 5

78 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER GT STADLER GT boilers belong to a new generation of firewood hot water heating boilers. With their wood gasification technology they enable modern and energy saving heating. They are constructed to burn all types of firewood of up to 54 cm or 33cm in length. Their combustion efficiency reaches over 90%. themselfs are designed and produced in Slovenia. By naming the product range STADLER we wished to show that the production is still active and adapts to new combustion conditions and techniques. In comparison with our boilers marked TR and LT, these boilers come with a simpler control. Nevertheless, they provide stable combustion processes enabled by the inovative construction. These boilers achieve excellent combustion parameters which are characteristic for wood gasification boilers. Quality production, controlled combustion process and high efficiency of these boilers beat the competition of the lower priced boilers by far. By using different types of wood, it is possible to achieve good combustion conditions in the boiler. Firewood burns in the lower part, whilst the supplied primary air leads the flame and wood gases downwards into the combustion chamber. When flue gases come through the burner nozzle, they are blown with controlled supply of secondary air. Flue gases mixed with the flame and fresh air swirl in the combustion chamber, and in touch with the red-hot fireproof clay, burn with extreme temperatures. The control regulates the combustion process via the temperature sensor in the chimney and sensors installed in the boiler and the accumulator. It also regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. Controlled supply of the combustion air enables low values of emmissions in flue gases which are significantly lower than the law regulated ones. s are equipped with an insulated hot combustion chamber made of fireproof clay which quickly reaches high temperatures and enables good combustion of wood gases. The efficiency boilers reache over 90% which points out the top-class echievement for boilers with lower level control without the Lambda probe. The hot combustion chamber enables the boiler to reach the optimal combustion Characteristics Unit GT 20 GT 30 process in only minutes. These boilers can be installed into systems equipped with hot water accumulators. We recommend the use of the heating system control because this is the only way to preserve different water layers in the hot water accumulator. Our boilers are in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, etc.). They are tested for pressure and water tightness, factory equipped with a thermal protection device and can be installed in closed heating systems. The permissible operating pressure of boilers equals to 3 bars. We recommend the use of firewood with humidity of 25% which is achieved by drying it outdoors for 2 years. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. The volume of the fireplace is 105 dm3 and can be loaded with approx. 30 kg of firewood. You should load the container with firewood to the top of the doors, while taking care not to load them too close to each other as this could cause jamming. Nominal heat value kw Lowest boiler power kw efficiency at nominal power % Combustion efficiency % Container volume l Loading door width and height mm 400 x x 350 water quantity mm Chimney connection diameter mm Permissible operating pressure bar 3 3 Required chimney draft Pa Max. flow temperature C weight kg Recommended accumulator size l height mm width mm depth mm Depth of the loading area mm Height of the chimney connection mm Delivery tube R" 5/4 5/4 Return tube R" 5/4 5/4 Supply discharge fitting R" 1/2 1/2 Thermal protection device fitting R" 3/4 3/4 Thermal protection device fitting 6 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

79 WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER PELET STAR Stadler PELET STAR hot water central heating boilers belong to a new generation of wood pellet boilers. They were designed by our company in cooperation with the Swedish company Ariterm. The BeQuem burner enabled the development of a completely automatic wood pellet boiler which guarantees reliable and safe operation with minimum cleaning and maintenance interventions. s are produced with the modern sheet metal treatment technique. Construction concepts provided the boiler with a touch of modern design, while respecting the ergonomic demands for the operation of the boiler. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN s are equipped with the CE 0036 marking and can also be installed in smaller rooms to provide comfortable and energy saving heating. The side of the boiler is equipped with the weekly wood pellet silo, whilst the large ash chamber allows longer intervals between cleaning. Construction of boilers allows easy access to all internal surfaces and hence easier cleaning and maintenance. We recommend you to install your central heating system with a hot water accumulator which allows optimum boiler operation with low energy consumption (low-energy constructions and transition periods). In case of bigger consumption, the hot water accumulator amortizes the current lower burner operation capacity. Special construction of the BeQuem wood pellet burner allows reliable operation and high level of safety. Wood pellet feeding is arranged with a double stoker system where the lower stoker feeds wood pellets into the lower part of the combustion chamber. With such wood pellet feeding the ash is pushed further and the combustion chamber automatically cleaned. Such feeding technique makes the burner appropriate even with wood pellets of weaker quality which can now often be found on the market. Fire safety is ensured with temperature sensors and the cell block. Ignition and control of the flame are controlled with a special sensor. Characteristics Unit PELET STAR Nominal heat value kw Lowest boiler power kw 5 20 efficiency at nominal power % 90, ,3-91 Combustion efficiency % 91,9-92,4 90,9-91,3 Wood pellet container volume l Cleaning door width and height mm 330 x x 250 water quantity l Permissible operating pressure bar 3,0 3 Max. flow temperature C Upper chimney connection mm Required chimney draft Pa weight kg Recommended hot water reservoir size l height mm Width of the boiler including the wood pellet container mm Depth of the boiler with the burner and the fan mm Height of the chimney connection mm Delivery tube 1 1 Return tube 1 1 Supply fitting 1/2 1/2 Electrical connection 230 V+10/-15 %/50Hz 80 W for operation; 200 W for ignition Combustion chamber made of high resistant alloy guarantees good combustion of wood pellets. Wood pellets are transported into the combustion chamber from below. Newly arrived pellets push the ash from the chamber, thus making cleaning of the chamber's burner unnecessary in the period of one heating season. Burner cleaning is simple. Unscrew it and simply remove from the boiler. LEGEND 1. Cell block 2. Transverse stoker 3. Fuel supply 4. Ignition electrode 5. Primary air pipe 6. Ignition pipe 7. Transport mechanism 8. Fan 9. Feeding stoker 10. Combustion chamber with wood pellets WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 7

80 WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER C 28 With the help of new innovative technologies wood pellet heating boilers enable comfortable, energy saving, and environment friendly heating. Firewood heating boilers represented the basis for the construction of wood pellet heating boilers. These boilers were constructed in cooperation with the HDG company and conform to the strictest regulations prescribed for such products. This claim is confirmed with the TÜV certificate. The boiler was reconstructed to burn wood pellets and now, in compliance with the prescribed flue gas emissions, enables combustion of wood pellets with efficiency of over 90%. s are equipped with an additional function which gives them advantage over other similar products. In case you run out of wood pellets or electric power, boilers also allow to burn firewood. Reorganization of the boiler to burn firewood is simple. Simply cover the opening of the burner and connect the draft control. The Swedish made burner allows integration with solid fuel boilers so that they serve as heat exchangers. Except for the environment friendly flue gases the burner operates in similar way as the oil burner. Ignition, operation and deactivation are automatic. Wood pellet feeding is performed with an extremely energy saving stoker which takes the pellets from the silo and feeds them into the burner. The burner can easily be set via the display. Combustion is regulated via the control installed on the burner. Burner operates in two levels in accordance with energy requirements. ADVANTAGES OF WOOD PELLET BURNING DEVICES construction is adapted to burn wood pellets, Enabled firewood burning, Completely automatic operation, Combustion with optimal efficiency, Good control enables energy saving operation, is made of 8 mm sheet metal, Efficiency of over 90%, No problems related to fuel preparation, Wood pellet supply similar to fuel oil supply, Care for the environment. Characteristics Unit C 28 PELET PX 22 GP 20 Nominal heat value kw 25 Lowest boiler power kw 10 efficiency at nominal power % 90,12 water quantity l 70 Chimney connection mm 130 Permissible operating pressure bar 3 Required draft Pa 13 Max. flow temperature C 95 weight kg 370 Recommended accumulator size l 1000 height mm 1070 width mm 797 Width of the boiler including the burner mm 1090 depth mm 660 Height of the chimney connection mm 780 Delivery tube 1 Return tube 1 Supply discharge fitting 1/2 Thermal protection device fittings 1/2 Electric connection 230 V/50 Hz 8 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

81 WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Stadler EKO PELET hot water central heating boilers were designed with combination of firewood boilers and Swedish made burners. In this way boilers with the BeQuem wood pellet burners became automated units for heating of living quarters. Unlike the use of fossil fuels, the use of local energy resources, such as wood pellets, is harmless to the environment and decreases heating costs. These wood pellet boilers are equipped with a control which allows completely automated operation of the boiler without constant regulation. They regulate the supply of pellets from the container and the combustion process. s are also equipped with a pellet ignition device and flame control. The burner activates automatically as soon as the sensor in the boiler detects fall of water temperature bellow the preset value, and deactivates as soon as this temperature is reached. The volume of the factory offered wood pellet container equals to 0.6 m3 which is enough for approx. 10 days of operation. Alternatively you can order a larger container with volume of 0,93 m3. Our company also offers elements for the construction of even larger wood pellet containers which can be assembled in your boiler room or the room next to it. These boilers can easily be rearranged into firewood heating boilers by unscrewing the flange screws, removing the burner and turning it into the position which does not interfere with the operation of the boiler. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Cleaning of the boiler is also very simple. Open the lower door and remove the ash collected in the drawer. From time to time it is also necessary to check if the combustion chamber is clean. In case you notice any slag residue, remove it adequately. We do not recommend you to disassemble the burner during cleaning, however if this is necessary please call our authorised repair service centre. After each rearrangement of the boiler for burning firewood, clean the fireplace of the boiler and the space under the grate. The construction of the burner is equipped with a display showing mode of operation and temperature. Under the display, there are some arrow keys which enable you to scroll along the simple menu. With the use of these keys you can set the operation of the burner or simply control its operation. Calculation of the required boiler power m 2 cm 0,30 Apartment x Living quarters x Heat loss size height coefficient Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of In case of simpler heating systems we recommend you to install a special pump. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C and then only emits the excess energy into the system. During the cool down phase, the pump and the three-way valve ensure that the water temperature in the boiler does not fall below 55 C, thus preventing the formation of condensate. If the system includes a hot water accumulator, the three-way mixing valve allows the accumulator to be filled. With the use of the water accumulator, better operation can be achieved, especially during transition periods when temperatures are not too low. model Wood pellet boiler capacity kw Firewood boiler capacity kw / 860 = Required boiler power Electric connection 240 V 50 Hz Power consumption 240 V 50 Hz Efficiency EKO PELET W 60 W 91,5 % EKO PELET W 90 W 90,7 % WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 9

82 WOOD PELLET AND FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Kompakt EKO pelet Kompakt wood pellet hot water heating boilers are equipped with wood pellet containers located above the boiler where the domestic water heater is generally installed. These boilers are appropriate for installation in smaller spaces where there is desire for comfortable and energy saving heating. s are produced left or right oriented. They can easily be rearranged into firewood heating boilers by unscrewing the flange screws connecting the burner and the boiler, removing the burner and turning it into the position which does not interfere with the operation of the boiler and its safe loading. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Fasten the line of the draft regulator to the primary air flap of the lower door. Remove the safety barrier and the rectifier from the boiler. After you finish the above procedure, the boiler is rearranged to use firewood. CHARACTERISTICS OF FIREWOOD BOILERS: Stadler EKO hot water central heating boilers are constructed to burn 33 cm long firewood (logs are to be loaded transversely) and 56 cm long firewood (logs are to be loaded longitudinally to the boiler). They are intended for operation in the 90/70 C mode. The new way of flue gas conduction improves combustion processes during the burning of firewood. Loading doors enable loading of large logs. Constructions of boilers are produced in accordance with regulations DIN 4751 B1.1, DIN 4702 and EN s are also equipped with the CE 0036 marking. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must ensure drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your wood pellets or firewood in a downwards direction, thus prolonging the combustion time of a single load. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces enables easy cleaning and maintenance. Burner position during firewood burning. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of model Eko Pelet Kompakt Firewood power kw Wood pellet capacity kw Delivery tube R Pellet silo for Kompakt l Self-standing pellet silo for Eko Pelet l water quantity l Weight EKO s kg L B H-Eko Kompakt DIMENSIONS (mm) Hs-Eko Pelet D F G d / / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

83 HOT WATER CENTRAL HEATING ACCUMULATORS MODEL: AT Hot water accumulators represent intermediate central heating elements and are used in modern heating systems. They are used for accumulation of the excess thermal energy produced by the boiler and for evenly regulated supply of energy to different consumers. Hot water accumulators are indispensable in systems with installed firewood, wood pellet, or wood chip heating boilers. Firewood heating boilers do not allow the complete control of power without significant interruption of the combustion process. Firewood combustion cycle brings excess thermal energy which consumers cannot use at that moment therefore it is conducted to the hot water accumulator. After the fuel has burnt and the heating elements cooled down, the automatic control takes care for transfer of hot water from the accumulator to heating elements. Our production programme includes hot water accumulators of various sizes: 500, 750, 1000, 1250, 1500, 1800, 2000, and 3000l. Accumulators are equipped with fittings for connection of heating circles, sensors and thermometers. The number of used fittings depends on the complexity of the planned heating system prescribed by the manufacturer at the time of sale of the product or by other professional subjects. Model / values Unit AT 500 AT 750 AT 1000 AT 1250 AT 1500 AT 1800 AT 2000 AT 3000 Volume l D-diameter mm D1+diameter including insulation mm H - height mm H angled height mm Total weight kg Permissible operating pressure bar Max. operating temperature C Take care that the angled height is not greater than the room height, as this would prevent the installation of the accumulator. D1 Our production programme includes several standard volume hot water accumulator types: AT AT B AT BI AT B2I AT B3I AT I AT 2I AT 3I AT 3I PB WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 11

84 FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO in EKOs Stadler EKO heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). Construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6cm. The above stated means, that it is possible to load the boiler with firewood of up to 40 cm and 56 cm in length. s EKO are to be loaded with 33 cm long firewood, whilst boilers EKO are to be loaded with 50 cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of flue gas conduction improves combustion processes during firewood burning. Large loading doors allow easy loading of firewood into the fireplace which can be loaded with large quantities of firewood, therefore we recommend you to burn your firewood in a downwards direction, thus prolonging the combustion time of a single load. The heater temperature control is performed by setting the desired temperature on the control cabinet which represents an integral part of the boiler equipment. Equipment of EKO boilers also includes quality enamelled domestic water heaters. They are equipped with an Mg-anode which serves for enamel protection. s with EKOs marking (s - solo) are not equipped with hot water heaters, but can be additionally bought and installed. Construction of boilers is made with 3D-designing in accordance with all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN s are equipped with the CE 0036 marking. and heater are tested for pressure and water tightness. The permissible operating pressure of the boiler equals to 3 bars. For the purpose of achieving high product quality, all integral parts of the boiler are made of quality materials. s are also factory equipped with thermal protection devices. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must enable drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your fuel in a downwards direction. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces allows easy cleaning and maintenance. SCOPE OF DELIVERY: with insulation, Thermal protection device, Domestic water heater for EKO boilers, Thermometer, Cleaning kit. Models EKOs 12 and 14 are not delivered with the domestic water heater Firewood Fireplace Delivery Heater Required Weight Weight model power size tube water water draft EKO s EKO DIMENSIONS (mm) EKO quantity quantity EKO-s kw dm 3 R l l Pa kg kg L B Eko s Eko D F G d / / / / / / / / / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

85 WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER HS HS boilers were developed on the basis of long years of experience in the field of development and production of heating equipment. s are intended for burning all types of wood. They are distinguished by long inclined loading doors and a large combustion chamber which allow simple use and loading of the boiler with large quantities of fuel. Chimney connection is located at the back side of the boiler. s are equipped with a combustion chamber and a pipe register with turbulators for better heat exchange. Chimney must be constructed in accordance with the SCHIEDEL table for solid fuel boilers. Draft must comply with the values stated in the table for the selected model of the boiler. Construction of the fireplace and the perfect insulation guarantee maximum fuel efficiency. s are to be loaded transversally with firewood of up to 36 cm in length. Fuel burns in the lower side part of the boiler. Installation of the grate in the fireplace and installation of the flap on the secondary air door significantly improve the combustion process. The installed return water preheater and the water-cooled grate prevent the low-temperature corrosion. Easy access to all internal surfaces allows easy cleaning and maintenance. By purchasing additional burner control and special burner doors, your boiler can be rearranged to burn fuel oil. For domestic water heating you must connect the boiler with a self-standing water heater, because the construction of the boiler does not enable you upgrade boiler with a heater. s are distinguished by quality production as they are made with laser cutting of metal sheet and robot welding. s are also factory equipped with a thermal protection device. SCOPE OF DELIVERY with lining and insulation Thermometer Cleaning kit LEGEND 1. Fireplace loaded with firewood 2. Flue pipes 3. Exhaust of flue gases with a flap 4. Water-cooled grate 5. Ash space, drawer 6. Pipe register cleaning opening 7. Return water preheating 8. Return tube 9. Delivery tube 10. Panelling with insulation 11. Loading doors 12. Doors for cleaning and relighting the fire 13. Primary air flap 14. Safety tube 15. safety flow, supply, discharge 16. draft control fitting R ¾ 17. connection thermometer sensor R ½ 18. Protection door vertical grate 19. Fireproof clay 20. Mixing channel 21. Secondary air rotating flap 22. Thermal protection device Model HS Loading Firewood door power dimensions kw Fireplace size dm 3 Chimney connection Ø water quantity l Required draft Pa Weight kg Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of Delivery Heater and return coonnection tube R R DIMENSIONS (mm) L B H L1 H1 A D x / x / x / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 13

86 WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 28 Stadler Central series boilers are constructed fur burning firewood. Combustion in the lower side part and the vertical 4-draft conduction of flue gases enable good transmission of flue gas heat to the heated water. Combustion in the lower side part classifies the boiler in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. Fireplaces are adapted to standard firewood lengths. Fireplace of the Central 28 boiler is adapted to be loaded with 33 cm long firewood. Special channel for the conduction of combustion air to individual combustion zones enables good combustion of fuel. The Central 28 boiler is equipped with a special fireproof clay combustion chamber where the previously not combusted flue gases in the fireplace are burnt. s also come equipped with a combustion grate made of grey cast iron which can be moved, thus enabling you to remove the ashes from the grate during the operation of the boiler. Additionally, the boilers are equipped with a thermal protection device and draft control. Vertically installed cleaning openings enable easy access to internal vertical channels. Construction of boilers respected all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN s are equipped with the CE 0036 marking. s are also factory equipped with a thermal protection device. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Good efficiency and minimum environmental nuisance, Automated draft control enables slow-burning, Moving grate enables cleaning during operation, Single load is sufficient for several hours of burning, The boiler is adapted to burn firewood and certified for German market. The use of certified materials provides long service life of the boiler. L SCOPE OF DELIVERY with lining Thermometer Draft control Cleaning kit C28 B1 128 B C 24 C 28C 24 C 28 H3 H3 H3 H2 H1 H1 H2 H H1 B1 B B L1B1 L1 B L1 B1 model CENTRAL Heat power kw Fireplace size dm 3 water quantity l Chimney Chimney Connection Ø Ø mm mm Required draft Pa Outflow inflow R Weight kg DIMENSIONS (mm) L L 1 B B 1 H H 1 H 2 H WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

87 WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 17 IN 23 Storey boilers are intended for installation and use in non-basement residential houses and residential apartment blocks with no central heating and no chance of classic boiler room installation. Combustion in the lower side part classifies these boilers in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. s are extremely energy saving, thus making the fuel consumption of a single heating season very low. Dimensions and visual appearance are adapted for installation in fitted kitchens. The central heating installation should be executed in a way that enables horizontal connection to the heating system (at the side of the boiler). Such installation enables the boiler to be levelled with the edge of the kitchen working counter. Pipes routed vertically behind the boiler will cause the boiler to be unaligned with the fitted kitchen. s are equipped with a three-way chimney connection and vertical chimney connection with a cover. They are appropriate for burning of dry firewood of up to 25 cm in length. s should be connected to an Ø 118 mm diameter chimney (23 kw boilers to Ø 128 mm). Chimney draft should equal to 20 Pa. We recommend you to measure the chimney prior to the installation of the boiler. In case of low quality chimneys, such chimneys should be arranged to enable optimal operation of the boiler. All boilers are equipped with a thermal protection device, whilst new models come with a flexible loading cover enabling easier fuel loading. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Installed cooking plate allows reheating of your dishes, Room with the installed boiler does not require additional radiators, Good efficiency and minimal environmental nuisance, Automated draft control enables slow-burning, Moving grate enables grate cleaning during operation of the boiler, Single load is sufficient for several hours of burning, Use of certified materials provides long service life of the boiler. SCOPE OF DELIVERY C17 C23 with lining Thermometer Draft control Cleaning kit Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of " 1 2" 3 4" " 70 1" 1 2" H " " " 1" " model CENTRAL Heat power kw Power (water) kw Power (environment) kw Container dm 3 Burner water quantity l Chimney Connection Ø mm Required draft Pa Outflow inflow R Weight cca kg H mm WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 15

88 DUAL FIREPLACE FIREWOOD AND FUEL OIL CENTRAL HEATING BOILERS MODEL: STADLER TOBI Stadler TOBI central heating boilers are constructed as extremely energy saving boilers due to the installation of fuel oil and firewood boilers in a single construction. Both boilers use a single water reservoir, but completely separated fireplaces. Such design enables automatic rearrangement from burning of one type of fuel to another which cannot be achieved with combined boilers. s are basically intended for burning firewood in the 90/70 C operating mode. The fuel oil part of the boiler activates automatically after all of the fuel from the firewood fireplace has been used and the temperature dropped under the preset value. The fuel oil part of the boiler does not activate if the firewood fireplace is full and the preset temperature is reached. In case you deactivate the automatic system, these boilers only operate by burning firewood. A more modern construction concept classifies these boilers among the new generation of eco-friendly products as they operate in a similar way as hybrid cars. The firewood fireplace is equipped with modern burning in the lower side part of the boiler which enables controlled long burning process lasting even over 3 ½ h. The fireplace allows you to burn 33 cm long firewood. s are equipped with a return water preheating system and a cast iron grate which improves firewood combustion processes. Loading doors allow loading of large pieces of firewood. The special fireplace constructed for burning fuel oil is equipped with a hot combustion chamber and a turbulator in the third draft. Its design enables top-class efficiency of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The fuel oil part of the boiler is equipped with the SELTRON control. These boilers cannot be upgrades with domestic water heaters. Domestic water heaters can be installed as separated units which are then connected to the boiler. Ba purchasing the domestic water heater additionally, it is possible to control the temperature in the domestic water heater with the help of a pump. panelling is enamelled in the RAL 3000 or RAL 2004 colour combination. Our boilers are in compliance with all regulations regarding safety at work. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN 303-5, and is equipped with the CE 0036 marking. s are also equipped with a thermal protection device. The central heating system must compulsory include one of the system for lifting the return water as this is the only way to use the boiler with lower powers. If the boiler is not connected with the system for lifting return water the boiler condensates and causes poor combustion. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C, and emits only the excess energy into the system. At the same time it prevents the return water with temperatures lower than 55 C to enter the boiler, thus preventing the condensation. If the system includes a hot water accumulator, the three-way mixing valve enables the accumulator to be filled. With the use of the hot water accumulator, better operation of the burning device can be achieved, especially during the transition periods when temperatures are not too low, but still demand heating. model TOBI Power (fuel oil) kw Power (wood) kw Fireplace size dm 3 water quantity l Required draft Pa Weight kg Chimney Connection (fuel oil) Ø Chimney Connection (wood) Ø width mm height mm Required door width to enter the boiler with panelling into the room Required door width to enter the boiler without panelling into the room Efficiency (fuel oil) ,2 81, ,4 81,5 % Efficiency (wood) % 16 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

89 FIREWOOD AND FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER EKOs and RLs These devices include two separate boilers. The basic boiler is the firewood boiler onto which the fuel oil boiler or gas oiler is installed. The firewood boiler is reinforced with two holders which enable safe installation of the fuel oil or gas boiler. Each boiler represents the best solution for itself as it is in compliance with all ecology standards. The boiler can additionally be upgraded with a separate domestic water heater, whilst the heating control takes place via the external control. Stadler EKOs heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). The construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6 cm, thus enabling you to load the boiler with firewood of up to 40 or 56 cm in length. s EKOs 25 are to be loaded with 33cm long firewood, whilst boilers EKOs are to be loaded with 50cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of conduction of flue gases improves the combustion processes during firewood burning. Large loading doors enable easy loading of firewood into the fireplace. s can be loaded with large quantities of firewood, therefore we recommend you to burn your fuel in a downwards direction, thus prolonging the combustion time of a single load. L1 B1 H1 d G1 D1 50 H L B d F1 G F D Special Stadler RLs fuel oil and gas boilers are produced with welded frameworks made of larger dimensioned materials. fireplaces are equipped with a hot reversible chamber and turbulators within the pipes which allow combustion with efficiency of over 93%. Flue gas exhaust emissions are lower than required by law, especially NOx, CO, whilst the flue gas temperatures in the chimney do not reach 180 C. s are in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). The basic equipment includes also the control cabinet for the regulation of the burner operation. Power Fireplace Required Weight Delivery L B H D F G d model les size water draft EKOs tube quantity EKOs kw dm 3 mm mm mm mm mm mm mm l Pa kg R / / / /4 Power Required Weight Delivery L 1 B 1 H 1 D 1 F 1 G 1 d model (fuel oil) water draft MVs tube quantity mm mm mm mm mm mm mm RLs kw l Pa kg R /4" /4" WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 17

90 FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER RL and RLs Special welded Stadler RL boilers are constructed for burning fuel oil or gas and are made of the thickest certified sheet metals. fireplaces are equipped with hot reversible chambers and turbulators within the pipes which allow top-class combustion efficiencies of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The boiler is in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). RL marked boilers are equipped with vacuum enamelled heaters for preparation of domestic hot water. Domestic hot water temperature can be controlled with the help of the pump. RLs boilers are delivered without the heater for preparation of domestic hot water. These boilers are distinguished by good 50 mm thick insulation. The panelling of the boiler is protected with powder enamelling. The basic equipment also includes the control cabinet for the control of burner operation. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of SCOPE OF DELIVERY RL RLs with lining and insulation control Water heater control If the delivery includes the base of the boiler it is necessary to consider its height of 270 mm. Hot combustion chamber and turbulators Cleaning brush L B As optional equipment you can install an electric heater (2 kw) for domestic water heating during the summer. We recommend you to purchase the additional heater at the time of your order, as the subsequent installation is more expensive and complex. Hs G F D H Power Water Flow Weight Weight Chimney model water heater return RL RLs DIMENSIONS (mm) RLs, RL kw quantity l l R kg kg Ø mm L B H Hs D F G / / / / WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

91 FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Euro HDG Euro boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all of the prescribed values. Contraction and production of the boiler are in accordance with all safety regulations. These boilers were granted the German innovation award and are equipped with the TÜV quality marking. Large fuel loading space significantly increases fuel reloading intervals. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection with the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. Combustion takes place in the lower side part of the boiler on the grate which allows wide selection of fuels. Along with the special combustion chamber, the robust and innovatively constructed burner nozzle provides swirling mixing of flue gases which ensures optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. Grates are massive and equipped with a practical cleaning opening. The loading shaft is made of 10 mm thick quality steel sheet. Pneumatic cylinders facilitate opening of shaft doors. The system bolt of the loading shaft cover enables safe loading. The spacious conical loading shaft can be filled with firewood or bulk material. If you select the right size of the device, you will be able to get the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include a hot water accumulator as such reservoir combined with the boiler control guarantees environment friendly combustion. The hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of the accumulator depends on customer s demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. Combination of the firewood boiler equipped with the hot water accumulator and the solar energy device meets the demands of the modern heating system. Lambda control enables very low emission values, high efficiency and low fuel consumption. The adjustable primary and secundary air motors provide accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process. Predtok 1 1/ Lambda Control constantly measures and displays the following parameters: Quantity of the remaining oxygen in flue gases, Temperature of flue gases for uniform efficiency, Temperature of the heating boiler and water reservoir, Lifting of the temeperature of the return water. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of Model Heat power Povratni tok 11/ objemka za praznjenje/ polnjenje 1/2 783 Vnosna mera Območje odpiranja For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure Lowest Loading Loading space Chimney Operating Required Max. flow boiler space width and water connection pressure draft weight temperature power volume depth quantity Ø C kw kw l mm l mm Bar Pa kg HDG Euro x HDG Euro x HDG Euro x Recommended accumulator size l WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 19

92 FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Turbotec LEGEND 1. Loading space (340 l), 2. Cleaning opening, 3. Lambda probe and the flue gas sensor, 4. Fan, 5. Loading from above optional and with additional payment, 6. HDG lambda control, 7. Loading doors - front, 8. Primary and secondary air control, 9. Cleaning opening Thermal protection device sensor 1 / 2 VL 1 1 / 4 varnostni toplotni izmenjevalec 1 / 2 RL 1 1 / 4 Praznjenje 1 / HDG Turbotec boilers are firewood heating boilers with large loading space of up to 340 l. they are intended tu burn firewood with lengths of up to 1 m, thus prolonging the interval between loadings. In case you have fine fuel at your disposal, you can also additionally order the upper boiler loading doors. Turbotec boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all prescribed values. Construction and production of the boiler are in accordance with all safety regulations. They are ideal for use in the craft industry, agriculture and forestry, and are equipped with the TÜV quality label granted by a German institution. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection to the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. The robust and innovative constructed nozzle provides good combustion. The interior of the combustion chamber is shielded with fireproof concrete. Swirling of flue gases in the combustion chamber provides optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. s are made of quality steel sheet. Primary and secondary air servomotors deliver the necessary air directly in the combustion zone. Primary air takes care for constant performance of the boiler, whilst the secondary air takes care for the lowest flue gas emission values. If you select the right size of the device, you will be able to obtain the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include the hot water accumulator as such accumulators combined with the boiler control guarantee environment friendly combustion. Installation of the hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of accumulators depends on customer's demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. HDG Turbotec boilers are equipped with HDG lambda control 1 which ensures very low emission values, high efficiency and low fuel consumption. Adjustable primary and secondary air motors deliver accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process Power Loading Loading Loading Chimney Required Operating Max. flow Model space volume space depth space width water quantity connection Ø draft pressure temperature weight kw l mm mm l mm Pa Bar C kg HDG Turbotec 50 L HDG Turbotec 60 L WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

93 HDG WOOD CHIP AND WOOD PELLET HEATING SYSTEMS MODEL: HDG Compact These boilers are appropriate for burning wood pellets and wood chips with humidity of up to 45%. s can also burn Class 6 and 7 fuels. The compact and favourable priced versions are appropriate for use in households, agriculture, craft industry and public institutions, basically everywhere where a reliable and economic operation is required. Constant power is provided by the automatic technology of angled or movable grates. s are equipped with automatic ignition via the hot air fan. Two large external ash collectors make operation and maintenance easy. s are distinguished by low emission values and optimum efficiency of over 90%. The reliable fuel loading technology and the fire extinguishing device provide absolutely safe operation. Cell block is especially accurately manufactured and takes care for proper loading. Vertical surfaces of the heat exchanger provide better heat transfer. In emergency situations boilers can also burn firewood. HDG Compact electronic control device of the boiler takes care for good combustion technology and is a product of our development programme. It can also be upgraded for control of different heating systems. All actual conditions of the operating device are shown on the display. Fuel loading takes place directly on combustion grates. Fuel supply and primary and secondary air can be adjusted independently. Even in case of bigger shares of non-combustible materials, the power stays constant due to the technology of angled grates. After reaching a certain loading level, the fuel ignites with the help of hot air. Automatic ignition increases the device control comfort. Device operates with optimum emission values. You should prevent long lasting smouldering during the time of ember preservation, thus preventing the contamination of heat exchanger and chimney surfaces. In combination with the fire extinguishing equipment, loading of the boiler via the patented cell block and feeding stoker guarantees perfectly safe operation. With the help of the cell block, the combustion chamber is completely separated from the silo and the transport unit and represents patented protection from the return fire. The next advantage lies in cutting of large firewood by the cell block into smaller pieces, thus creating ideal combustion conditions. The circular skimming device for takeover of wood mass from the silo is appropriate for simple, unproblematic takeover of wood chips, wood pellets, wood shavings, sawdust and wood briquettes from the silo. Maximum stoker length is 6 m (max. weight of fuel = 250 kg/m3). The takeover device can be installed also in larger containers, provided that they do not require complete emptying. Two pretightened joint levers are equipped with rotating spring feathers which rotate and skim the wood mass onto the stoker. Material takeover takes place along the transverse and open transport stoker. In case of square and round containers (6 m diameter) emptying takes place with the transverse stoker. The loading system can be installed in different positions in 180 radius according to the option of the silo connection. These systems are described in details in technical brochures. Our experts will make a special offer with technical solutions which meet the customer's demands for each individual device. For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure. Power Power Combustion Combusted air water Operating Required Flow Model area gas temperature flow quantity quantity pressure draft temperature weight kw kw C g/s l Bar Pa C kg HDG Compact , , HDG Compact , HDG Compact , HDG Compact , HDG Compact , HDG Compact , HDG Compact , HDG Compact , WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 21

94 FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER Z doors open in the left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating systems regulation, control equipment of the most renowned foreign manufacturers is used. Stadler Z heating boilers are Slovenian products with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards and are produced in standard versions for operation with 4 bars of overpressure. For higher pressures (>10 bar), modified construction is used. You can choose between 90/70 C and 110/90 C operating modes. The ideal construction and the flame pipe type of flue gas conduction provide optimum combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with railings intended for cleaning and supply and with the entrance and exit ladder. B SCOPE OF DELIVERY with left or right opening doors fixation panel Electric switch cabinet Lacquered pannelings with insulation Z Flue Model Heat Flue Safety Supply power water pipe return tubes discharge weight B D E F H H quantity 1 I K L L 1 L 2 Ø cca Z kw l mm DN DN R kg WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

95 LOW PRESSURE STEAM BOILERS MODEL: STADLER ZP Stadler ZP low pressure steam boilers are used for production of steam with overpressure of 0.5 bars. They are Slovenian made with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards. The ideal construction and the flame pipe type of flue gas conduction provide optimal combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with a ladder and walkable platform with railings. doors open in left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating system regulation, control equipment of the most renowned foreign manufacturers is used. SCOPE OF DELIVERY Low pressure steam boiler with left and right opening doors Two-colour lacquered panneling with insulation Base plate for the installation of the burner Operation and safety pressostats (3 pcs) Level switch Inspection glass (2 pcs) Pressure gauge Pressostat installation fitting ZP Model Power Steam Steam Safety Condense DN Flue quantity takeover tubes tubes pipe weight A B C D H H1 H2 H3 H4 L L1 Ø cca ZP kw kg/h DN1 DN2 DN3 R mm kg x x WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 23

96 GAS AND FUEL OIL HOT WATER BOILERS MODEL: STADLER ZV In these times, when the environmentally aware part of the world tries to lower the emissions of greenhouse gases into the environment, it is very important that the fossil fuels heating systems operate as efficiently as possible, with perfect combustion, and low fuel consumption. Our company already several years ago decided to actively contribute to the development of such heating devices with no impact to the environment. On the basis of 40 years of tradition in the field of boiler production and intensive investments into development, our company produced a new family of hot water boilers named STADLER ZV. These boilers are constructed on the triple draft principle with low Nox emissions. Due to the low load of the combustion chamber ( 1,2 MW/m3) and the conduction of flue gases through the pipe register, these boilers provide optimum combustion with top-class efficiency. s are made in accordance with Directive 97/23/CE PED and the Slovenian SIST EN12953 standard regarding gas or fuel oil burning. s are also equipped with a substantially dimensioned heat part. At the time of dimensioning of flame pipes, flue pipe packages and the water part, special attention was given to thermodynamic compliance and fast transfer of temperature to the water. s are also equipped with large volume water parts appropriate for optimum temperature control in different operating conditions. Inspection openings for entrance into the water part are easily accessible and allow easy access. s are well insulated and installed on a support frame. The operating overpressure is adapted to customer's demands. Our company produces boilers intended for pressures of 6-16 bars with the maximum operating mode of up to 160 C depending on the order or the investor's temperature mode. Minimum operating mode equals to 60 C. The external boiler fitting must provide protection of the hot water boiler against too low temperatures of the return tube. Equipment of the boiler can also include the system for protection against condensation. Good boiler insulation prevents heat loss into rooms and enables stable thermal operation. s are insulated with two layers of 60 mm thick Type ZV Heat power water quantity Transport weight Operating weight water side flue side Flue side volume width lengt height kw l 6 bar 16 bar 6 bar 16 bar mbar mbar m 3 B L H ,3 1, ,7 1, ,2 2, , ,6 4, ,8 5, ,7 5, ,5 6, ,7 8, ,5 8, ,5 12, ,2 14, ,5 16, ,5 19, , WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

97 LMF10 ALUR lamella insulation which makes total insulation 120 mm thick. Construction of the boiler enables to connect the burner to a special flange, which is to be installed on the neck of the combustion chamber. Combined with»low NOx«burners, our boilers achieve very low emission values (NOx < 100 mg/kwh). These boilers are equipped with double doors at the front side which open in the left and right direction, thus enabling easy access to pipe exchangers. Back side of boilers includes inspection opening of the combustion chamber, opening for the control of the flame and the flue cabinet. The flue cabinet is equipped with inspection covers and the pipe with a valve for condensate discharge. The flue cabinet can also be installed with a motorised flue flap for prevention of ingress of cool air into the boiler when it operates in idle mode. Above the flue cabinet, it is possible to install a heater for reduction of flue gas temperature which additionally increases the efficiency of the device and lowers the fuel costs. Such installation can lower the fuel consumption for up to 10%. The equipment of the heater can also include the system for protection against condensation. Lower fuel consumption enables additional decrease of CO2 emissions and lesser impact on the environment. Low resistance at flue gas and water sides, low radiation loss, and simple maintenance and cleaning represent additional advantages of these boilers. equipment includes safety equipment in accordance with SIST EN12953 standard, including the intermediate flange piece for installation of the safety and control equipment. The quality control of Weishaupt burners enables top-class control of the combustion process. Our company upgrades the Weishaupt control cabinets in such way, that they also allow the control of peripheral systems in the boiler room. Output signals of the boiler and control cabinet enable the regulation and control of the operation via the CNS. If the boiler room contains several boilers, they can be controlled via the cascade regulation with diagnostics of the device operation. s are equipped with the platform and a ladder. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation, operation control and maintenance operations. Our company manages all inquiries in a project way and adapts boilers to customer's demands. At the investor's demand, the company can take care for complete delivery of the equipment with all installations. In the name of the investor, our company can also elaborate all necessary documents for the preparation and execution of the project, and the technical acceptance. Modern 3D planned ZV boiler 's cross section shows the construction design which provides combustion with low flue gas emissions. Substantially dimensioned material cross sections do not burden the materials and prolong the service life. s are distinguished by the modern laser and CNC technology machining, whilst joint welding is performed with the help of powder welding processes. Welding is strictly controlled by the internal control and outside institutions. Type ZV Torch Burner Flue Flue Flow, Flow, Flow, Safety Safety Safety Water Bleeding diameter connection height connection connection height return PN 16 return PN 16 return PN 16 valve 6 bar PN 16 valve 8 bar PN 16 valve 16 bar PN 16 discharge Ø H1 Ø H2 20 C 30 C 40 C DN DN DN PN 40 PN WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 25

98 WOOD RESIDUE, WOOD CHIP AND WOOD PELLET HEATING SYSTEMS BIOFLAMM Biomass is becoming more and more important economic factor as it enables energy independence and discontinuation of fossil fuel use which represent excessive impact on the environment. Due to the increasing prices of fossil fuels and financial country incentives for biomass equipment, investment into this equipment become very profitable in short-term. Our company has been producing boilers and biomass equipment for almost 30 years and has developed and still develops a wide range of products. Equipment is technologically adapted so it can be installed practically in every room, even in smaller boiler rooms which were planned for fuel oil boilers. The company strives for improvement of products, especially regarding the combustion technique, with solutions for combustion of chemically compromised wood residues and with the use of wide range of granulation and moisture. s are adapted also for burning wood pellets, thus allowing the use of biomass boilers even in cities, industrial facilities and other settlements. BIOFLAMM HEATING SYSTEMS MODEL: VE/SREB s are produced with the installed reactor with the step grate. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. In the first draft, boilers with integrated burner are shielded with fireproof clay A 40 or A 60, depending on the fuel the device is planned for. Construction of the boiler allows to burn wood residue with humidity of up to 45%. s are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms and railings, intended for cleaning and supply, and with entrance and exit ladders. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. At the flue gas exhaust it is necessary to install a fan and a flue gas deduster, thus achieving dedusting of up to 80 mg/m3. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. The entire device is controlled by the Lambdamatik micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 2 MW, temperatures 140 C and operating pressure 4.5 bars). model Power kw water quantity l height mm width mm lengt mm Safety flow Flow return Flue connection mm Weight kg V DN 50 DN V DN 50 DN V DN 60 DN V DN 65 DN V6 / DN 65 DN V DN 65 DN V DN 65 DN V DN 65 DN V DN 80 DN V DN 80 DN V DN 80 DN V DN 80 DN V DN 100 DN V DN 100 DN WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

99 Model Heating power kw power kw Weight kg BIOFLAMM HEATING SYSTEMS MODEL: TRB/VA This heating device comprises the pre-fireplace reactor TRB and the VA boiler. The combination of these two components is used everywhere where the combustion conditions are difficult due to the higher humidity or due to the problematic fuel. Bioflamm multi draft VA boilers are used as heat exchangers and places for flue gas burn down. s are equipped with two horizontal drafts and three vertical drafts routed through the pipe packages. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. In especially tough operating conditions boilers are shielded with quality fireproof clay in the first draft. Large dimensioned drafts and vertical pipe packages provide this heat exchanger with low temperature flue gases and enable high efficiency. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). The automatic Bioflamm TRB pre-fireplaces with movable grates and automatic deashing enable the combustion of very problematic fuels. Reactors are constructed as a water-cooled pipe cage construction. The frame of the burner is shielded with quality fireproof clay A 40 or A 60, depending on the fuel the device is planned for. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Grates are installed next to each other, are simple, can be individually replaced, and form several movable grate layers. In case of extra humid, ash rich, or slag forming fuels, the Bioflamm degassing reactors with special air injection systems improve the combustion with their controlled combustion air fans. The primary air fan regulates the degassing process on the grate, whilst the secondary air fan enables combustion during the degassing of the formed flue gases. Separation from the fireplace and the boiler enables fast control in accordance with DIN 4751 Part 2. Reactors are produced in two construction versions; TRB N for humid fuels and TRB T for dry fuels. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). In the past years, the company also developed an extra version of reactors marked TRB LK for connection of grain dryers or dryers of the sawdust accumulated during wood pellet production. Reactors are made of double-walled steel sheet frame where the air is directed into individual combustion zones. On the internal side, reactors are shielded with fireproof clay, whilst their external side is substantially insulated to prevent heat radiation into the environment. Grate movements and combustion air injection are similar to those of the basic version. The entire TRB/VA device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Water quantity l Flow return DN Lengt mm Width mm Height mm Center of the flame pipe mm Diameter of the flame pipe mm Height to the stoker mm TR-B 5N TR-B 6N TR-B 7N TR-B 8N TR-B 9N TR-B 10N TR-B 11N TR-B 12N TR-B 13N TR-B 14N TR-B 15N WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 27

100 BIOFLAMM HEATING SYSTEMS MODEL: TREB These heating devices were developed with the integration of transverse TRB reactors and VE boilers. This version is very good in coping with problems of combustion of all types of problematic fuels and allows installation in smaller boiler rooms. s allow the combustion of wood mass with humidity of up to 50% and wood mass with chemical substances which accumulate in the wood industry and could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are also appropriate for burning wood pellets and are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The external side of the boiler is equipped with a special system of channels for the supply of primary air under the grates. This feature improves the formation of wood gas as well as the combustion process. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply, and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. Production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The entire device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m 3. s are factory shielded with fireproof clay A 60, which is resistant to high temperatures released during combustion. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. Model Heat power kw water quantity l height mm width mm lengt mm Safety flow Flow Flue connection mm TREB DN 40 DN TREB DN 50 DN TREB DN 50 DN TREB DN 50 DN TREB DN 50 DN TREB DN 65 DN TREB DN 65 DN TREB DN 65 DN TREB DN 65 DN TREB DN 65 DN TREB DN 80 DN Weight kg 28 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

101 BIOFLAMM HEATING SYSTEMS MODEL: SRF-RK These boilers are appropriate for burning relatively dry wood chips with humidity of up to W 45, and wood pellets. They include a fireplace and a heat exchanger. Fireplaces with the movable step grate represent the basic part of these boilers. Fireplaces are shielded with quality fireproof clay. Construction of the boiler enables burning relatively clean wood residue and wood pellets. s are equipped with a large combustion chamber which enables good combustion. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and enable high efficiency. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are shielded with fireproof clay A 40 or A 60, depending on the used fuel and operating conditions. In case the boilers burn dry fuel or wood pellets, they are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionaly install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Smaller boilers are delivered welded as a whole, whilst, larger boilers come in two parts which are later assembled together in your boiler room. Assembly in the boiler room is especially welcome in case of low passages where the transport into the boiler room is less favourable. Type Bioflamm SRF-RK Power (flame) kw Useful boiler power kw Weight kg water quantity l Flow Return tok DN Lengt mm Width mm Height mm SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK SRF-RK WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 29

102 BIOFLAMM KURILNI SISTEMI MODEL: TRF-RK 30 These boilers are appropriate for use where the biomass humidity cannot be controlled or where the humidity cannot be dried out and therefore remains very high. In the first and second draft, boilers are shielded with quality fireproof clay. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Construction allows to burn inferior and problematic humid wood residues which could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are equipped with a large combustion chamber with the first inversion of hot flue gases over the fuel where the first phase of fuel drying begins. The large quantity of fireproof clay radiates the temperature on the fuel which moves along the grate, thus drying it additionally. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. The well-dimensioned second draft serves also for deposition of large particles of floating ash. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and high efficiency. s are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is constantly controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. Standard scope of microprocessing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is Type Power Useful Weight water Flow Lengt Width Height Bioflamm (flame) boiler power quantity Return possible to supply customers with a control for remote TRF-RK kw kw kg l tok DN mm mm mm regulation and inspection of the combustion system and TRF-RK for the control of peripheral units. At the flue gas exhaust TRF-RK of the boiler it is necessary to install a flue gas deduster. TRF-RK Where the demands are very strict it is necessary TRF-RK to additionally install electric or fabric filters. Fabric TRF-RK filters enable cleaning of dust particles of up to TRF-RK mg/m 3. Smaller boilers are delivered welded as a TRF-RK whole, whilst larger boilers come in two parts which are TRF-RK later assembled together in your boiler room. Assembly TRF-RK in the boiler room is especially welcome in case of TRF-RK low passages where the transport of the boiler is less TRF-RK favourable. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: , Fax: , wvterm@wvterm.si

103 DEVICE CONTROL Controls with the Lambda probe Lambdamatika and Optimatika+ are installed in Rital cabinets which include all control elements for the entire system, continuous motor drives, protection of drive units, and the device for calling of 6 telephone numbers. On special order they can also be installed with modems for connection with the remote control. The cabinet is equipped with the main switch (depending on the supply power of electric motors) and the emergency switch. Doors of the cabinet are equipped with the microprocessor with a display and a keyboard for direct access into the combustion parameter setting program. Use of the program and the input of desired data is simple as the program allows scrolling with cursor keys and includes simple commands. The programme is made as a multi-level programme device operator level and repair or fine-tune expert level. VISUALIZATION The communication package for remote control of data and for the visualization of operation is used for control when the operator is out of the boiler room. The connection is established with the help of the modem and internet, or directly via the cable in case of small distances. In case of the cable connection, the visualization works trouble-free for 24 h, but demands an amplifier in case of distances greater than 200 m. Long-term connection via your telephone will cause disturbances during monitoring of current values due to the signal strength fluctuation. Significant data about device operation and reports of disturbances can be followed on the PC display. This way enables the operator-supervisor the access to all required data, which is why he can quickly react in cases of device malfunctioning. On the basis of these data, the supervisor makes corrective measures and adapts the operation to desired parameters. If the supervisor is unable to repair the malfunctioning he must immediately contact the manufacturer's service team which will take care for it with no major problems. With the permission of the investor, the manufacturer's service team can enter into the communication system. The visualization allows access to different levels of operation, depending on the data to be checked. All levels enable formation of excel charts and analyses of operation in individual time periods. Because this is a complex heating device, we recommend the operator to plan adequate maintenance interventions on the basis of number of hours of operation. COMPANY PRESENTATION OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z Besides this trademark we are also present in the wood biomass market with Bioflamm and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on top-class laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: , Fax: , wvterm@wvterm.si 31

104 Valvasorjeva 73, 2000 Maribor Tel.: , Fax: Industrial store: Tel.: , Fax: wvterm@wvterm.si art a design - Kramberger & Uran

Rozp.UE2015/ kw kw

Rozp.UE2015/ kw kw Rozp.UE2015/1189 7 kw - 7000 kw Production Company Heiztechnik is a modern factory that produces boilers for burning solid fuels from 3,9 kw do 7 MW and complete container boiler rooms and other heating

More information

Forward-looking and energy effi cient Biomass heating

Forward-looking and energy effi cient Biomass heating English Forward-looking and energy effi cient Biomass heating 349-499 kw Large buildings Hotel complexes Housing estate projects 1 Competence is our success... HERZ FACTS: 50 companies Group headquarter

More information

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

HDG K SERIES. Wood pellet boiler.   The perfect alternative to fossil fuels. Receive up to (56.81) April 2013 Receive up to 2635 RHI back every year for the next seven years HDG K SERIES Wood pellet boiler The perfect alternative to fossil fuels www.euroheat.co.uk The K Series pellet boiler,

More information

Biomass Pellet Boilers

Biomass Pellet Boilers Biomass Pellet Boilers simplicity, modern design and technological perfection biomass green energy Quality doesn t have to cost the earth KOVAN Ekoline with its headquarters in Gračanica (BIH) where the

More information

Combined boiler. for solid fuel and pellets

Combined boiler. for solid fuel and pellets Combined boiler ATTACK WOOD&PELLET for solid fuel and pellets W W W. A T T A C K. S K MODEL STRUC TURE OF THE AT TACK BOILERS THE NEW LINE OF ATTACK BOILERS FOR WOOD AND PELLETS 3000 000 6000 4 ATTACK

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

English. Heating with logs & wood pellets 20-40

English. Heating with logs & wood pellets 20-40 English Heating with logs & wood pellets 20-40 1 Competence is our success... HERZ FACTS: 60 subsidiaries Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees in

More information

Rozp. UE 2015/

Rozp. UE 2015/ Rozp.UE2015/1189 11.2017 Production Company Heiztechnik is a modern factory that produces boilers for burning solid s from 3,9 kw do 7 MW and complete container boiler rooms and other heating appliances.

More information

Heating with log wood

Heating with log wood English Heating with log wood De Luxe 18-40 Lambda 18-40 1 Competence is our success... HERZ FACTS: 60 subsidiaries Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees

More information

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL BIOTECH THE FUTURE OF HEATING PZ 35 RL Heating with renewable energies is the future and you will not only contribute to the environment, you also will reduce massively your annual energy cost. The Biotech

More information

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4 Wood gasification process... Wood as a fuel... Boiler construction - its elements...4 Boiler construction - materials...4 EKO advantages...4 Boiler construction - schematics... Boiler dimensions... Boiler

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA WOOD CHIP HEATING HPK-RA -60 Wood Chip Heating HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA Description Cell wheel

More information

Aquaflam Wood boiler stoves and fireplace inserts

Aquaflam Wood boiler stoves and fireplace inserts www.hsflamingo.com Aquaflam Wood boiler stoves and fireplace inserts AQUAFLAM wood boiler stoves and fireplace inserts from the HS Flamingo workshop have many above-standard features. These innovative

More information

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA HPK-RA -60 HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA DESCRIPTION Cell wheel Wood chip burner in high-quality heat-resistant

More information

Boiler Technical Specifications (2013)

Boiler Technical Specifications (2013) ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)

More information

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+ INSTALLATION AND OPERATING INSTRUCTIONS Ariterm 60+ CONTENTS General.... 2 Installation.... 4-5 Installation of temperature limit valve... 6 Measurements and connections... 7 Technical specifications and

More information

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply

More information

USER MANUAL 9kW LILLY PELLET STOVE

USER MANUAL 9kW LILLY PELLET STOVE USER MANUAL 9kW LILLY PELLET STOVE Table of Contents.Overview of Stove Parts... 2.Technical Characteristics... 3 3.Important Information... 4 4.Pellet Specification...5 5.Technology... 6 6.Installation...

More information

Your guide to. Biomass Heating Systems

Your guide to. Biomass Heating Systems Your guide to Biomass Heating Systems Biomass Boiler up to 70% savings on heating costs 1 TONNE OF FUSION PELLETS 7 Years Parts and Labour Warranty FREE * OPTION 1 FREE BOILER FREE biomass boiler FREE

More information

LOG BURNING BOILERS. Zeroridge Biomass Ed 17A

LOG BURNING BOILERS. Zeroridge Biomass Ed 17A A LOG BURNING BOILERS A3 ALOG BURNING BOILERS Overview HDG and SHT log boilers zeroridge Model information Heat output Fuel options and loading options Page HDG R Series Easy controller Fuelling chamber

More information

TECHNICAL AND OPERATIONAL DOCUMENTATION

TECHNICAL AND OPERATIONAL DOCUMENTATION METAL AND BOILER FACTORY 28-100 Busko-Zdrój, Owczary, ul Przemysłowa 3 Tel No +4841 378 46 19, fax +4841 370 83 10 TECHNICAL AND OPERATIONAL DOCUMENTATION SAS MULTI FLAME BURNER ADAPTED FOR BURNING OF

More information

Masterflamme Convection Wood Stoves Perfect combustion with unique design

Masterflamme Convection Wood Stoves Perfect combustion with unique design www.hsflamingo.com Masterflamme Convection Wood Stoves Perfect combustion with unique design Panoramic glass The view of the burning flames is intensified by the heat-resistant panoramic glass. massive

More information

Log fired heating system

Log fired heating system Log fired heating system De Luxe 18 De Luxe 20-40 Lambda 20-40 Competence is our success... HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owned 2,400

More information

Eco Angus Wood Pellet Boilers

Eco Angus Wood Pellet Boilers Eco Angus Wood Pellet Boilers ISO 9001 ISO 14001 1 Contents 3 Our product philosophy 3 Our approach 3 Manufacturing credentials 4 Orligno 400 4 Boiler construction 5 Boiler description 5 Burner 6 Technical

More information

HERZ ECO-Line Heating with logs or wood pellets

HERZ ECO-Line Heating with logs or wood pellets English HERZ ECO-Line Heating with logs or wood pellets Lambda 18-40 10-60 1 Competence is our success... HERZ FACTS: 50 companies Group headquarter in Austria Research & development in Austria Austrian

More information

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection. ETA PE-K ETA PE-K The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw A passion for perfection. www.eta.co.at ETA PE-K Pellet heating for domestic and commercial

More information

MANUAL. Page 1/44

MANUAL.     Page 1/44 MANUAL FOR INSTALLATION AND OPERATION OF A HEATING SYSTEM, CONSISTING OF HOT WATER WOOD PELLET BOILER FROM SERIES PELLETHERM V4 AND AUTOMATED WOOD PELLET BURNER FROM SERIES GP IV http:// www.greenecotherm.eu

More information

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS W W W. A T T A C K. S K MODEL STRUC TURE OF THE AT TACK BOILERS THE NEW LINE OF ATTACK BOILERS FOR WOOD AND PELLETS 3000 000 6000 4 ATTACK FD PELLET yattack

More information

JÄSPI Solid Fuel Boiler

JÄSPI Solid Fuel Boiler JÄSPI Solid Fuel Boiler JÄSPI Solid Fuel Boilers Firewood used in solid fuel heating is a cost-efficient, renewable, and environmentally friendly energy source. The length of firewood can vary from 0.3

More information

Efficient CHP-plant 150 kw

Efficient CHP-plant 150 kw www.vep.at PROJECT DESCRIPTION Efficient CHP-plant 150 kw Our pilot plant near Tulln Our custom-made solution for decentralized energy supply with steam technology! V. E. P. Fördertechnik GesmbH Guntramser

More information

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax : CENTROMETAL d.o.o. Glavna 12 40306 Macinec Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL MANUAL USE AND MAINTENANCE Cm Pelet-set TUPS-3-2008-eng-E-N CONTENT 1. Introduction.. 2. Delivery

More information

product catalog 2014 The most awarded central heating boilers in Poland

product catalog 2014 The most awarded central heating boilers in Poland product catalog 2014 The most awarded central heating boilers in Poland For many years our company actively supports many ecological projects to protect the environment and reducing the cost of heating

More information

High quality boiler stoves and fireplace inserts

High quality boiler stoves and fireplace inserts High quality boiler stoves and fireplace inserts Aquaflam boiler stoves and fireplace inserts + Combustion chamber and water jacket made from 6mm steel sheet + + + damper to regulate chimney draft cooling

More information

it warms us up! PRICE LIST

it warms us up! PRICE LIST warms us up! 09.2018 PRICE LIST Production Company Heiztechnik is a modern factory that produces boilers for burning solid fuels from 3,9 kw do 7 MW and complete container boiler rooms and other heating

More information

Installation & Manual. Model T-25

Installation & Manual. Model T-25 Installation & Manual TR Central Heating Stove With Solid Fuel Model T-25 Tested according to DIN EN 13240 For product efficiency and emission values, see the declaration of conformity! TABLE OF CONTENTS

More information

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty. ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided

More information

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 0, 6, 5, 4 kw CLASS IN EN 0/5 Innovation with meaning BioClass NG IN EN 0/5 CLASS DOMUSA has managed

More information

STILE BEAUTY AND TECHNOLOGY

STILE BEAUTY AND TECHNOLOGY STILE BEAUTY AND TECHNOLOGY STILE, in line with your style Designer White Bordeaux Silver Grey MODEL Nominal input kw Nominal output kw Output to the water min. / max. kw HYDRONIC PELLET FIRE SPACE HEATING

More information

Heating with wood chips & pellets

Heating with wood chips & pellets Heating with wood chips & pellets 20-60 kw 80-499 kw Competence is our success HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owned 1,600 employees in

More information

Heating with wood chips

Heating with wood chips Heating with wood chips YOUR RELIABLE PARTNER Present years on the market 110 for over 20-60 Our success is our expertise... HERZ-Armaturen Ges.m.b.H The company Founded in 1896, HERZ has had an ongoing

More information

Max-3 Steel Shell Boiler

Max-3 Steel Shell Boiler Max-3 Steel Shell Boiler Responsibility for energy and environment Output range 500 to 3000 kw 1 Why choose Max-3? The Hoval Max-3 boiler delivers market-leading efficiency and cost effective heating performance.

More information

Heating with wood pellets kw

Heating with wood pellets kw Heating with wood pellets 0-60 kw Competence is our success... HERZ FACTS: 60 companies Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees in over 00 countries

More information

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40) TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set (14-35 kw) For boilers: EKO-CK P 20-40 (EKO-CK 20-40) EKO-CKB P 20-40 (EKO-CKB 20-40) TUPS-K-02-2011-E-N-ENG CONTENTS 1. Introduction....... 2. Status

More information

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic Smart Heating Technology Ltd. U Statku 653/24, 717 00 Ostrava-Bartovice Czech Republic AUTOMATIC BIOMASS BOILERS Smart 150 500 1500 kw SMART INDUSTRIAL PARK Ostrava-Bartovice 18 000 m 2 Automatic Boilers

More information

Pioneers of heating with biomasses

Pioneers of heating with biomasses Pioneers of heating with biomasses Greń company was established in 19 by the founder: Bolesław Greń, for whom the main goal since the founding of the Company was the quality of products and meeting the

More information

Wood Chip and Pellet Boilers. Turbomat TM 500.

Wood Chip and Pellet Boilers. Turbomat TM 500. Wood Chip and Pellet Boilers Turbomat TM 500 www.froeling.com High-tech without limits From the very beginning Froling has specialised in the efficient use of wood as a source of energy. The name Froling

More information

Easyfire Standalone biomass pellet boiler

Easyfire Standalone biomass pellet boiler Easyfire Standalone biomass pellet boiler DESIGN Essential and pleasant AESTETIC, small size If the humanity is in balance with the resources of nature, the respect for the environment will be possible.

More information

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK CONTENTS EN ATTACK DPX THE WOOD GASIFYING BOILER... 4 1 INTRODUCTION... 6 2 3 4 1.1 GENERAL DESCRIPTION...

More information

Biomass. Biomass solid fuel boiler range

Biomass. Biomass solid fuel boiler range Biomass Biomass solid fuel boiler range Biomass Fuelling positive change For more than150 years, Baxi has been at the forefront of heating technology Baxi leads the way with new and pioneering heating

More information

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL. Turbomat Wood Chip and Pellet Boilers Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL www.froeling.com High-tech without limits From the very beginning Froling has specialised

More information

Masterflamme Convection Wood Stove

Masterflamme Convection Wood Stove www.masterflamme.cz Masterflamme Convection Wood Stove Perfect combustion with unique design convection wood stove masterflamme choose your colour... cream - metallic brown - velvet black Thanks to its

More information

Importance of a Draught Regulator

Importance of a Draught Regulator Importance of a Draught Regulator The purpose of a chimney (stack) is to generate a draught (draft) that will transport smoke and fumes away from the point of combustion. The chimney design and arrangement

More information

Cm Pelet-set (60-90 kw)

Cm Pelet-set (60-90 kw) CENTROMETAL d.o.o. Glavna 12 40306 Macinec Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT Cm Pelet-set (60-90 kw) For boilers: EKO-CK P

More information

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens Main components The bigger the need of heat output is. the bigger the components (storage. boiler. chimney etc.) In private houses the output need of the boiler is about 25 40 kw and in farms from 60 kw-

More information

English. Heating with logs & wood pellets 20-40

English. Heating with logs & wood pellets 20-40 English Heating with logs & wood pellets 20-40 1 Competence is our succes HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owner 2.400 employees in more

More information

Installation, operation and care Firewood boiler Vedolux 40 UB

Installation, operation and care Firewood boiler Vedolux 40 UB Installation, operation and care Firewood boiler Vedolux 40 UB 2008-09-23 Ver 2 Replaces: 05-11 VEDOLUX 40 UB Notes 0809 To be completed when the Vedolux 40 UB is installed Serial number:... Installation

More information

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40) TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT Cm Pelet-set (14-35 kw) For boilers: EKO-CK P 20-40 (EKO-CK 20-40) EKO-CKB P 20-40 (EKO-CKB 20-40) TUPS-M-11-2015-E-N-ENG CONTENTS 1. Introduction.....

More information

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS. PE1 Pellet PE1 Pellet Pellet boiler - Canada PE1 Pellet Awarded the APPROVED FOR EPA 2020 EMISSION LIMITS Austrian Ecolabel! www.froeling.com 1 Heating with pellets For more than 50 years Froling has specialised

More information

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H 1. 2. 3. 4. 5. 6. 7. Fire box door Ash pan door Air inlet control Fuel drawer Side flue gas connector Oven door with double glass Protective cover for

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS CENTROMETAL d.o.o. Glavna 12 40306 Macinec Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set (60-90 kw) For boilers: EKO-CK P 70-110 TUPS-90K-09-2015-E-N-eng

More information

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L Chopped wood Chips/sawdust Wooden pieces Chip briquettes.. the useful and economic alternative to oil, gas and electricity Your

More information

Your home heating since 1888

Your home heating since 1888 Product range Your home heating since 1888 Viadrus product catalogue Product catalogue company profile, milestones Company profile VIADRUS has been a traditional purely Czech manufacturer of grey cast

More information

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems 1 EkoLine Wood Pellet Boilers EKOLINE boilers have been designed specifically for the purpose of heating water to temperatures

More information

AIREX 2S WOOD PYROLYSIS SUCKING FAN

AIREX 2S WOOD PYROLYSIS SUCKING FAN AIREX S WOOD PYROLYSIS SUCKING FAN To optimize green energy AIREX S constitutes the evolution of the firewood boilers range: total gasification inverted flame with sucking fan especially suitable to the

More information

With its particular heat retencion capacity, cast iron is the perfect

With its particular heat retencion capacity, cast iron is the perfect Wood-fired Stoves 2 STOVES The traditional heat With its particular heat retencion capacity, cast iron is the perfect basis for our efficient stoves. All Nestor Martin stoves are manufactured with quality

More information

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL. Turbomat Wood Chip and Pellet Boilers Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL www.froeling.com High-tech without limits From the very beginning Froling has specialised

More information

THE WOOD GASIFYING BOILER ATTACK SLX, DPX, DP STANDARD / PROFI / LAMBDA TOUCH / COMBI PELLET

THE WOOD GASIFYING BOILER ATTACK SLX, DPX, DP STANDARD / PROFI / LAMBDA TOUCH / COMBI PELLET THE WOOD GASIFYING BOILER ATTACK SLX, DPX, DP STANDARD / PROFI / LAMBDA TOUCH / COMBI PELLET W W W. A T T A C K. S K ABOUT THE COMPANY ATTACK ABOUT THE COMPANY ATTACK, s.r.o. y The largest Slovak producer

More information

tççç= ÜÉ~íáåÖ çéíáçåë

tççç= ÜÉ~íáåÖ çéíáçåë 3. tççç= ÜÉ~íáåÖ çéíáçåë There are several different types of wood-heating appliances to choose from. Each type is intended for a particular use, and each has its own set of advantages and disadvantages.

More information

Fully-automatic Wood Pellet central heating

Fully-automatic Wood Pellet central heating Total comfort and reliable operation Highest level of comfort - Fully automatic fuel feed - Maintenance-free operation - Stable room temperatures Touch control panel with Internet connection Highly efficient

More information

TopGas Wall Hung Condensing Gas Boiler

TopGas Wall Hung Condensing Gas Boiler TopGas Wall Hung Condensing Gas Boiler Output range 30 to 80 kw Why choose TopGas? TopGas wall-hung boilers offer compact and advanced gas heating technology built to the high quality standards you would

More information

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics Multi Energy Boilers Duo 1 & 2 Triplex 0 & 3000 Biotriplex Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics Jaspi Multi Energy Jaspi has been developing and manufacturing highlong

More information

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN 330-5 norm Biomass - the curse of energetics or the only fuel of the future? The real

More information

modern heating devices

modern heating devices PELLET AND WOOD-FIRED BOILERS modern heating devices www.hkslazar.pl PELLET BOILERS SMART FIRE thermal efficiency 92,1% ceramic burner The top-class materials used in the burner guarantee long-lasting

More information

Heating with pellets kw

Heating with pellets kw YOUR RELIABLE PARTNER Heating with pellets Present years on the market 110 for over 10-60 kw Competence is our success HERZ FACTS: 35 companies Group headquarters in Austria Research & development in Austria

More information

Operating manual. Wood pellet boiler. PL M 15 and PL M 25

Operating manual. Wood pellet boiler. PL M 15 and PL M 25 Operating manual Wood pellet boiler PL M 15 and PL M 25 November 29, 2007 Important! This operating manual contains important information for the operator. The boiler must be professionally installed and

More information

GAS AND PELLET BURNERS

GAS AND PELLET BURNERS GAS AND PELLET BURNERS PIZZA OVENS BREAD OVENS - BOILERS HOT AIR GENERATOR WWW.FORNOLEGNAMATIC.IT WWW.CASADELBRUCIATORE.IT WWW.FORNIPIZZERIA.COM INDEX PELLET GRANVULCANO B-H SQUARE & B-H ROUND SUPERTERMICO

More information

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19 OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers

More information

Solid biofuel solutions

Solid biofuel solutions Solid biofuel solutions Clean heat with locally produced fuel Solid biofuels are the individually most important component in the conversion to a sustainable energy mix. Heat production from wood based

More information

- 12, , TECHNICAL INSTRUCTIONS

- 12, , TECHNICAL INSTRUCTIONS HEATING TECHNIQUE Centrometal d.o.o. - Glavna, Macinec, Croatia, tel: +8 7, fax: +8 7 TECHNICAL INSTRUCTIONS for installation, use and maintenance of hot water boiler and installation of additional equipment

More information

R A N G E C O N C E P T

R A N G E C O N C E P T RANGE CONCEPT 2018 BODART & GONAY Founded in 1957, Bodart & Gonay have always had a passion for a job well done job. Designer of the first fireplace inserts in the late 1970s, after selling thousands of

More information

Leading European manufacturer of fireplace stoves and fireplace inserts

Leading European manufacturer of fireplace stoves and fireplace inserts Leading European manufacturer of fireplace stoves and fireplace inserts ROMOTOP Fireplace inserts Almost 700,000 households all around the world enjoy ROMOTOP products today. Every product that leaves

More information

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40 TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40 2 INDEX INDEX Safety information.......4 Technical data...5 Boiler features...6 Technical information........7 Fuel...... 8 Construction and function...... 9 Hydraulic

More information

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN To respected customer, We are very pleased for your trust and your decision to buy our product. You made a good choice,

More information

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw The Biomass Heating System Product information KWB CLASSICFIRE AND KWB COMBIFIRE Log-wood and pellet heating system Optionally available as COMBIFIRE KWB CLASSICFIRE Log-wood and pellet heating system

More information

ISO 9001 TUV CERT CE

ISO 9001 TUV CERT CE ISO 9001 TUV CERT CE INSTRUCTION MANUAL CONTENT 2 1. Boiler application 2. Principle of work 3. Description of the controller 3.1. Front panel of EKOSTER 2 3.2. Main functions of EKOSTER 2 4. Gasification

More information

Waste/Multi Oil Boilers from Flexiheat

Waste/Multi Oil Boilers from Flexiheat Waste/Multi Oil Boilers from Flexiheat At a time of rising fuel costs, the Flexiheat FMOB universal/waste oil boiler range, which can burn nearly all vegetable, animal, conventional and waste oil, will

More information

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE Carbel models: C-60 Plus C-70 Plus C-80 Plus C-100 Plus C-70 Plus Double-sided C-80 Plus Double-sided C-100 Plus Double-sided CARBEL C/ Ciudad de Cartagena,

More information

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set For boilers CentroPlus 25/35 and CentroPlus-B 25/35 (solid fuel and wood pellets fuel firing) TUPSCP-K-11-2016-ENG CONTENTS 1.Introduction 2. Status

More information

Rapid. Suspended Warm Air Heater. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment! Rapid Suspended Warm Air Heater Caring for the environment! RAPID The QUICK and ECOLOGICAL Suspended Heater Our RAPID heaters were conceived and designed for the heating of industrial and commercial buildings.

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER INSTRUCTION MANUAL Content 1. Boiler application...3 2. Principle of work...3 3. Description of the controller...4 3.1. Front panel of

More information

MULBERRY STOVES. cast a warm eye on life

MULBERRY STOVES. cast a warm eye on life MULBERRY STOVES cast a warm eye on life 1 2 MULBERRY STOVES MULBERRY STOVES At Mulberry Stoves we have assembled a team of dedicated and experienced people who are determined to provide products that represent

More information

Cassette inserts and fireplace doors

Cassette inserts and fireplace doors Cassette inserts and fireplace doors Open fireplaces shine in a new splendour Cassette inserts and fireplace doors Technology. Accuracy. Future orientated. Spartherm is the name for innovative fireplace

More information

PELLET BURNER PV 350

PELLET BURNER PV 350 PELLET BURNER PV 350 INSTRUCTION MANUAL v1.1 1 PRODUCT DESCRIPTION...3 2 SAFETY RULES...3 3 WARNINGS...4 4 INSTALLATION INSTRUCTIONS...5 4.1 BOILER REQUIREMENTS...5 4.2 PELLET CONTAINER...6 4.3 INSTALLATION

More information

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance: P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60 Technical Datasheet FrÖling P4 Pellet Boiler The P4 is a patented, wood pellet boiler available in four sizes with outputs from 35,800197,900 Btu/hr. Benefits

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information