BYPASS AIR TERMINAL UNITS
|
|
- Sarah Fox
- 5 years ago
- Views:
Transcription
1 BYPASS AIR TERMINA UNITS 3
2 SINGE DUCT PRESSURE DEPENDENT BYPASS SINGE DUCT PRESSURE DEPENDENT BYPASS SINGE DUCT PRESSURE DEPENDENT SBP 0 SERIES SBP 0: BASIC AIR TERMINAS SBP 0: Dimensions TOP VIE Description eight and ength: All basic terminals are mm in height and mm in SAFID SBP 0 Series bypass air terminals are designed for single duct constant air volume (CAV) systems in order over all length except unit with E and at down stream will have mm length. to deliver variable air flows to occupied spaces. Variable air volume control is achieved by directing supply air flow either to the room or to the bypass port in direct response from the room thermostat. hen the room temperature Controls: The SBP Air terminals can be specified with electric controls. Standard control are Belimo actuator modulating type. rises above the cooling setpoint,the actuator will modulate the primary damper at fully open position while the air flow Standard Connections: SSlip and Drive Slip connection. is at maximum. hen the room temperature fall below the cooling setpoint, the actuator will modulate or close the primary damper, then the bypass port damper will open to divert or dump the excess supply air into the return air ceiling plenum. Dumping supply air into return air ceiling plenum varies the zone supply air volume while the supply fan system remain at constant air volume. The SBP air terminals are supplied with round or oval spigot inlet. They are available with a variety of accessories. They can be specified with sound attenuator, electric heater, hot water coil, multiple outlet plenum and other optional accessories.the accessories (except for the multiple outlet plenums) are shipped factory attached and have standard slip & drive oulet connections. Standard Construction Casing: Terminal casing, inlet plate & damper built of 22 gauge galvanized steel sheet, conform to ASTM A, FQ, G90 zinc coating. Insulation: mm thick acoustic lining with a strong and dimensionally stable oven Glass Fiber Fabric (GF) facing, 4kg/M3 density, complies with the requirements of NFPA 90A. Options Option 1: Code SF Slide on Flange connections for discharge side. Option 2: Code SA Air Terminal with factorymounted Sound Attenuator. Option 3: Code OP Air Terminal with factorymade Multiple Outlet Plenum. Outlets extend 0mm beyond either side of the air terminal casing. Option 4: Code E Air Terminal with factorymade Multiple Outlet Plenum. Outlets extend 0mm beyond either side of the air terminal casing. Option 5: Code Air Terminal with factorymounted ot ater Coil on the outlet of the Air Terminal casing. Option : Code FC Air Terminal with mounted Flexible Connector on the inlet collar of the Air Terminal casing. Option 7: Code M Air Terminal with Belimo Actuator (modulating type). Option : Code CB Air Terminal with Control Box. Option 9: Code TC Air Terminal with a Digital Room Temperature Controller. ARI Standard 0 FRONT VIE MODE SBP SBP SBP 4 SBP 4 SBP 4 SBP 4 (in) 1 2 INET SIZE FAT OVA 3 x 2 5 x 2 x CASING SIZE SIDE VIE 41
3 SINGE DUCT PRESSURE DEPENDENT BYPASS SINGE DUCT PRESSURE DEPENDENT BYPASS SBP 0 SA: AIR TERMINAS IT DONSTREAM SOUND ATTENUATOR SBP 0 E: AIR TERMINAS IT DONSTREAM EECTRIC EATER SBP 0 SA: Dimensions SBP 0 EO, ET, EFT: Dimensions with Open, Tubular or FinTubular Coil TOP VIE TOP VIE FRONT VIE SIDE VIE FRONT VIE SIDE VIE MODE SBP SA SBP SA SBP 4 SA SBP 4 SA SBP 4 SA SBP 4 SA (inches) INET SIZE SBP 0 SA SOUND ATTENUATOR (SA) 1 2 FAT OVA 3 x 2 5 x 2 x MODE SBP E SBP E SBP 4 E SBP 4 E SBP 4 E SBP 4 E (inches) 1 2 INET SIZE FAT OVA 3 x 2 5 x 2 x SBP 0 EO The minimum straight portion after the electric heater up to elbow or any fittings that will change the airflow s direction must be equal to minimum length of mm. 2. Contact SAFID for electric heater details.
4 SINGE DUCT PRESSURE DEPENDENT BYPASS SINGE DUCT PRESSURE DEPENDENT BYPASS SBP 0 : AIR TERMINAS IT DONSTREAM OT ATER COI SBP 0 OP: AIR TERMINAS IT MUTIPE OUTET PENUM SBP 0 : Dimensions Plenum Arrangement Multiple outlet plenums can be supplied in the following arrangement and the dimensions will be as per the customer s requirement. TOP VIE ARRANGEMENTA ARRANGEMENTB FRONT VIE SIDE VIE ARRANGEMENTC ARRANGEMENTD MODE SBP SBP SBP 4 SBP 4 SBP 4 SBP 4 (inches) INET SIZE 1 2 FAT OVA 3 x 2 5 x 2 x SBP The minimum straight portion after the hot water coil must be equal to the diagonal of the electric heater s internal dimension. 2. Contact SAFID for hot water coil details. ARRANGEMENTE ARRANGEMENTF Plenum construction: 22 Ga. GI or as required, ining: mm x 4 kg/m3 or as required. ined and unlined plenums can be provided to required collar dia. As per above arrangements. All the collars to be provided with manual VCD (volume control damper) and hand quadrant.
5 PERFORMANCE DATA PERFORMANCE DATA Table 1: NC evels if ined Rectangular Duct is Fixed to the Downstream Side of Terminal box Table 2: NC evels if Unined Rectangular Duct is Fixed to the Downstream Side of Terminal Terminal Size (in) Air Flow Inlet Static (in.g.) Inlet and Attenuator Static (in.g.) CFM m 3 /s Discharge Sound Power evel Octave Band Center Frequency (z) 1kz 2kz 4kz NC Terminal Size (in) Air Flow Inlet Static (in.g.) Inlet and Attenuator Static (in.g.) CFM m 3 /s Discharge Sound Power evel Octave Band Center Frequency (z) 1kz 2kz 4kz NC The performance data shown is based on tests conducted in accordance with ARI Standard 0 and ASRAE Standard Measurement of Sound Power evels is in accordance with International Standard ISO 41 comparison method. 3. Discharge NC levels on this table reflect a reduction of environmental affect, 5 feet of lined metal duct the same size as the air terminal discharge, 3 feet lined flexible duct, outlet reflection and space effect The performance data shown is based on tests conducted in accordance with ARI Standard 0 and ASRAE Standard Measurement of Sound Power evels is in accordance with International Standard ISO 41 comparison method. 3. Discharge NC levels on this table reflect a reduction of environmental effect, 5 feet of lined metal duct the same size as the air terminal discharge, 3 feet lined flexible duct, outlet reflection and space effect
6 EECTRIC EATERS FOR BYPASS TERMINAS EECTRIC EATERS FOR BYPASS TERMINAS SBP 0 E : AIR TERMINA IT DONSTREAM EECTRIC EATER SBP 0 E: AIR TERMINAS IT DONSTREAM EECTRIC EATER Optional Electric eaters Optional Electric eaters OPTION NO. 1 Stainless Steel Tube Coil: OPTION NO. 2 Open Coil: Construction: The heating element of electric heater is made from stainless steel tube, SS type, EN The stainless steel tube heating element is not electrified and it will get hot (3 ) but you will not get an electric shock if you shoud reach it. It has a density which will keep it warm for approximately 3 minutes after the power is switched off and therefore very good to control with a time proportional thyristor regulation or with European standards EN heaters are tested for electrical safety and approved for EMC by SEMKO and comply with European standards EN 011 and EN 021. It also comply with the requirements in the ow Voltage Directive, VD 72/ EEC. Contructions: The open coil type heating element is made from a high grade resistance wire. Each heating coil element is designed to the customer s wattage specification. A guage heavier that a normal guage wire is used, giving a longer coil to maintain the required resistance for a given wattage. The casing is made from galvanized steel sheet as standard. Optional casing can be made from alumized or stainless steel. The casing is made from steel sheet with aluminum zinc coating which is more corrosion resistive than the galvanized steel sheet. Basic Electric eater Code ET: 1. The basic electric heater have no builtin temperature regulation controller. 2. In case of thermal over load, it has two builtin over heating protections, one is automatic reset and other one is to be manually reset. 3. The basic electric heater have a builtin pressure switch to detect the pressence of air flow passing through the electric heater. The power supply to the electric heater must be interrupted if the supply fan or air flow stopped. This function can be connected to the incoming power supply to the electric heater. 4. The number of k steps is available from 1 to 3 steps. 5. The power supply is 0V/1P/0Z from 0.5 k up to k and 0V/3P/0Z from 3kw up to kw. Electric eater with Built In Temperature Regulation Controller Code ETR: 1. The electric heater with builtin electronic temperature regulation controller called thyristor controls heating by means of so called time proportional regulation (Pulsi/Pause Technology). This gives a very precise continuous variable temperature regulation control of the heaters in response to the temperature requirements of the room sensor. The builtin controller is made for an external 0V control signal from BMS or similar. 2. It has also builtin automatic and manual reset over heating protection and a pressure switch to detect the pressence of air flow passing through the electric heater. 3. The power supply is 0V/1P/0Z from 0.2k up to 5.5kw and 0V/3P/0Z from k up to k. For more details, refer to the Electric Duct eater section of this catalogue. Basic Electric eater Code EO: 1. The basic electric heater have no builtin temperature regulation controller. 2. In case of thermal over load, it has two builtin over heating protections, one is automatic reset and the other on is to be manually reset. 3. The basic electric heater has a builtin air flow switch to detect the presence of air flow passing through the electric heater. The power supply to the electric heater must be interrupted if the supply fan or air flow stopped. 4. The number of k steps is available from 1 to 3 steps. 5. The power supply available is 0V/1P/0Z or 4V/3P/0Z.. The maximum k rating is k. Electric eater with BuiltIn solid state proportinal controller Code EOS 1. The heating element is controlled simultaneously with the builtin solid state controller. The builtin controller is made for an external 0 VDC control signal from BMS. 2. It has also a builtin automatic and manual reset over heating protection and air flow switch to detect the presence of air flow available is 0V/1P/0Z or 4V/3P/0Z. 4. The maximum k rating is k. For more details, refer to the Electric Duct eater section of this catalogue. For more details, please see Duct eater catalog on chapter 11. 4
7 ORDER REFERENCE DETAIS ORDER REFERENCE DETAIS Order Details Order Example Order Code: Model No: =Inlet Size No. =Inlet Size No. 4 =Inlet Size No. 4 =Inlet Size No. 4 =Inlet Size No. 4 =Inlet Size No. SBP aaa bb cc dd ee ff gg hh ii jj kk Example No. 1 Bypass Air Terminals are capable of delivering 1 CFM at in.g. Inlet static pressure with maximum discharge NC. Air terminal should be with Belimo actuator and control box. Selected Model: SBP 4 Using Table1, SBP 4 will meet the required in.g. inlet static pressure and the discharge NC level is <NC 20. Options: Make Type :SAFID :SBP 4MCB SA =ith discharge sound attenuator Qty :1 pc OP =ith multiple outlet plenum ET ETR =ith stainless steel tube coil electric heater =ith stainless steel tube coil electric heater and builtin temperature regulation controller powered by external 0.V control signal from BMS or similar. Example No. 2 Same as Example No. 1 but with discharge Sound Attenuator at Inlet & Attenuator pressure of 0. in. G. EO EOS =ith electric heater with open coil =ith electric heater with open coil and builtin Selected Model: SBP 4 solid state proportional controller powered by external 0.V control signal from BMS or similar. =ith discharge hot water coil Make :SAFID k =Power rating of electric heater Type :SBP 4SAMCB 1,2,3 =Required number of steps Qty :1 pc M =ith Belimo actuator TC =ith digital room temperature controller T TB CB P =ith stepdown transformer from 220V to V for actuator/controller =ith terminal block for transformer =ith control box =ith perforated sheet behind acoustic lining Example No. 3: Same as Example No.1 but with open coil electric heater, 2.5k, 1 step. SF FC =ith slide on flange on discharge side =ith flexible connector 1. If the dischage side connection is not specified, slip & drive is the standard connection. 2. If the actuator, transformer, terminal block and control box is not specified, the standard supply is with extended shaft only for actuator connection. Selected Model: SBP 4 Make :SAFID Type :SBP 4EO2.5k 1M CB Qty :1 pc Example No. 4 Same as Example No. 1 but with open coil electric heater, 5k, 2 steps with digital room temperature controller. Selected Model: SBP 4 Make Type Qty :SAFID :SBP 4EO 5k2MTCCB :1 pc
AIR TERMINALS & DUCT HEATERS.
AIR TERMINALS & DUCT HEATERS. TABLE OF CONTENTS. 4 2 CAV AIR TERMINAL UNITS 3 BYPASS AIR TERMINAL UNITS 52 DIGITAL THERMOSTATS FOR AIR TERMINAL UNITS 2 3 VAV AIR TERMINAL UNITS 4 5 SINGLE DUCT PRESSURE
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationBypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS
BYPASS TERMINAL UNITS DVAC, One Of The Premium Workshops Specialized in Duct Fabrication has Executed Several Projects (Residential, Governmental, Commercial, Industrial & Institutional). 2 BYPASS TERMINAL
More informationSINGLE DUCT TERMINAL UNITS
Performance Data AHRI Certification and Performance Notes Model Series 3000 asic Unit AHRI Certification Rating Points VAV: Fiberglass Inlet Size Airflow cfm l/s Min. Inlet Ps w.g. Pa Discharge Sound Power
More informationAIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems
233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationCatalog C: McQuay Horizontal Concealed Fan Coil Unit
Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationSECTION AIR DUCT ACCESSORIES
SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control
More informationCLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE
CONSTANT VOLUME LINEAR CEILING DIFFUSER 12 CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL
More informationChilled Water DOAS Fan Powered Terminal Units
Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner
More informationSECTION DUCTWORK
SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationeco PREMIUM ENERGY RECOVERY UNIT» Technical instruction
Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...
More informationSERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB
SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB TROX (U.K.) LTD CAXTON WAY GB-THETFORD NORFOLK IP24 3SQ TEL: 01842 754545 CONTENTS 1. INTRODUCTION 1. 1 DESCRIPTION 1.2 PACKAGING AND STORAGE 1.3 HANDLING
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More information45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:
SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationphoto by PFC Price Fan Column
photo by www.mrobinsonphoto.com PFC Price Fan Column Typical Applications The Price Fan Column (PFC) is a vertical fan unit designed to discharge into a raised access floor plenum. The unit s compact design
More informationSECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.
SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.
More informationRosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS
10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationStandard Duct Heaters Open Coil
HUA Slip-In and HUP Flanged Heaters The 80% Rule HEATREX recommends the heater should occupy at least 80% of the actual inside area of the duct, as shown in Figure 45. Only small amounts of air will bypass
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationGuide Specifications PART 1 GENERAL 1.01 SUMMARY
Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control
More informationSquare Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and
Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns.
More informationVAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC
VAV TABLE OF CONTENTS FS/ rueger models FS and fan powered terminal units were designed for optimal performance in noise sensitive applications. These series and parallel fan terminals utilize built-in
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationModular Heating & Ventilating Unit Model IGX-HV
Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit
More informationVERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled
FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationVertical Air Handler Unit
Bulletin 20-019 (September 2016) Vertical Air Handler Unit For cooling, the unit is designed for R-410A refrigerant (both A/C and Heat Pump) or a chilled water coil. For heating, the unit offers an optional
More informationCleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY
PART I - GENERAL 1.1 SUMMARY A. This section addresses the general requirements for air handling distribution systems, including air handlers, ductwork, ductwork accessories, terminal units, air devices,
More informationEASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE
CONSTANT VOLUME CEILING DIFFUSER 8 CCD/CSD/CRD3 EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW LOW NOISE NO MAINTENANCE WIDE RANGE HEATING AND COOLING TERMINAL REHEAT AVAILABLE RICKARD
More informationSECTION AIR COILS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 82 16 AIR COILS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in the section
More informationiq Star LYRA II chilled beam cassette
iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationTechnical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil
MDL SOLUTIONS Technical Catalogue NA Version PDWL AECM LSTAT Series Hydronic EC Ducted Fan Coil Hydronic Fan Coil Platform Introduction Company Introduction HVAC Solutions Sonkor Global MDL SOLUTIONS Technical
More informationSEQUENCE OF OPERATIONS
SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,
More informationEASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE
CONSTANT VOLUME CEILING DIFFUSER 8 CCD/CSD/CRD3 EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW LOW NOISE NO MAINTENANCE WIDE RANGE HEATING AND COOLING TERMINAL REHEAT AVAILABLE RICKARD
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationWater-Cooled Self-Contained Units
CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A
More informationInstallation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015
Installation and Maintenance Manual IM 1093-1 Single Duct VAV Terminals Group: Controls Part Number: IM 1093 Date: February 2015 Table of Contents Introduction.... 3 Revision History...3 Reference Documents...3
More information4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available
The Neptronic electric heater is manufactured using the most advanced technologies available. Total automation from design to production using integrated CAD/CAM systems not only assures maximum efficiency,
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationFAN POWERED VAV TERMINALS
FAN POWERED VAV TERMINALS Models VFR, CFR and CFRQ INSTALLATION, OPERATION AND MAINTENANCE MANUAL All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog data
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationCONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER
ELECTRONIC VARIABLE VOLUME LINEAR DIFFUSER 4 VLN 1 CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER ENERGY
More informationDESIGNING MODULAR VAV SYSTEMS
FORM 5.2 REV 0905 THERMA-FUSER THERMALLY POWERED VAV DIFFUSER DESIGNING MODULAR VAV SYSTEMS MODULAR VAV SYSTEMS The Therma-Fuser diffuser is a simple stand alone device that provides VAV control when supplied
More informationFCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual
FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FAN POWERED TERMINALS Receiving Inspection Prior to removing the shipping material, visually inspect the packing materials. There
More informationDACC Health Sciences Building Air Handler Assessment/Study
DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.
More informationInstallation and Maintenance Manual IM 1102
Installation and Maintenance Manual IM 1102 Parallel Fan Powered Variable Air Volume (VAV) Terminal Box Group: Applied Air Systems Part Number: IM 1102 Date: October 2010 Model MQFVI5 Table of Contents
More informationHOTEL CHILLED BEAM IQ STAR SILENCIA
HOTEL CHILLED BEAM IQ STAR SILENCIA TECHNICAL CATALOGUE 2 IQ Star Silencia Hotel Chilled beam - Technical catalogue IQ STAR SILENCIA HOTEL CHILLED BEAM Silencia unit is designed for use in hotel bedrooms,
More informationT-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS
PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity
More informationTechnical Report #3 Mechanical Systems Existing Conditions Evaluation
Mechanical Option Technical Report #3 Technical Report #3 Mechanical Systems Existing Conditions Evaluation Instructor: Dr. Bahnfleth 11.15.04 Building Sponsor: CCG Facilities Integration Table of Contents
More informationTLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser
TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser Therma-Fuser Systems Models: TLW-C VAV cooling only TLW-CW VAV cooling with constant volume warm up TLW-D Manually adjustable blades TLW-RAD
More informationTHERMA FUSER SIDEWALL LINEAR VAV DIFFUSER
THE ELW INTEROPERABLE THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER FORM 56.1 REV 0707 SPECIFICALLY DESIGNED FOR INTEROPERABILITY The ELW provides more information about what s happening in the space than
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationVEX100 series Air handling units with cross-flow heat exchanger
Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationCatalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration
Destiny Indoor Air Handler Models 002 030 Catalog 580-8 Horizontal Configuration Vertical Configuration Table of Contents Introduction.... 2 Certification...2 Smoke Control and Management Systems...2 Features
More informationT6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES
T7A, T7A,B, TA,B, TB Digital Fan-Coil Thermostats XE/XE00 SERES FEATURES PRODUCT DATA Attractive modern styling with digital display makes the thermostat ideal for offices or hotels. Hotel card key input
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More informationCustom Duct Heaters. Special Applications
Special Applications Air Conditioning & Air Handling Units For more than 55 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 49). A wide
More informationSEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT
SEQUENCE OF OPERATION GUIDELINE AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT Document: VAV-HTG rev1 Revision: 1.0 Rev. Date: July 22, 2011 NOTES: 1. THIS SEQUENCE
More informationFAN POWERED VAV TERMINALS
FAN POWERED VAV TERMINALS Models VFR, CFR and CFRQ INSTALLATION, OPERATION AND MAINTENANCE MANUAL All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog data
More informationTO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
Tech Sheet Do not discard AI Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock. PECAUTIOS
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationCatalog ThinLine Vertical Unit Heaters. Type FHVC, FHVH, FHVS, FHWC Vertical Design. Model FHVC. Model FHVS
ThinLine Vertical Unit Heaters Type FHVC, FHVH, FHVS, FHWC Vertical Design Catalog 723-3 Model FHVC Model FHVS Nomenclature and Certification... 3 ThinLine Vertical Unit Heaters...3 AHRI Certification...3
More informationProduct Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling
Product Data 28CB, Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Direct-expansion evaporator coils easily accommodate upflow or horizontal light-commercial applications Features/Benefits
More informationGreensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com
Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and
More informationADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM
ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT February 29, 2012 RFP NO: 17 PROJECT: Josephine County Justice Center HVAC Upgrades BID CLOSING DATE: NO CHANGE: March 8, 2012 / NOT LATER
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationCommercial Heating Products. Our products do more in a wide range of applications. Expect More.
Commercial Heating Products Our products do more in a wide range of applications. Expect More. Indeeco pioneered the application of duct heaters in commmercial construction applications. Today, Indeeco
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationGLOBAL FINISHING SOLUTIONS
GLOBAL FINISHING SOLUTIONS > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > Create balanced building pressure and maintain proper comfort levels > Introduce
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationFDCLP2 Low Profile, Series Flow Fan Powered Terminal Unit
ow Profile, Series Flow Fan Powered Terminal Unit Typical Applications The is an ideal solution for areas that require constant volume air delivery when ceiling space is limited or restricted. ow sound
More informationHorizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9
ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery
More informationProduct Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling
Product Data 28CB, 28LA Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Copyright 2001 Carrier Corporation 28LA Direct-expansion evaporator coils that easily accommodate upflow
More informationVIFB Coil Technical Guide
TGVIFB-3 VIFB Coil Technical Guide VERTICAL TUBE INTEGRAL FACE AND BY-PASS HEATING COILS FOR PREHEATING Since 1875, the L.J. Wing Company has been a leader in providing innovative solutions for diffi cult
More information15900 HVAC INSTRUMENTATION AND CONTROLS
15900 HVAC INSTRUMENTATION AND CONTROLS PART 1 GENERAL - Andover Controls BAS system is the standard for the University, and may be specified as a proprietary item. 1.0 RELATED DOCUMENTS A. Drawings and
More informationEnergy. The Energy ducted units have been designed. Heat Recovery Unit
Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc.,
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationiq Star LYRA II chilled beam cassette
Key features The LYRA II cassette is an active chilled beam for ventilation, cooling and heating. This diffusion system offers high flexibility thanks to the combination of Flow Pattern Control, Coanda
More informationFan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10
Fan Laws Keith Miller Samuel Tepp Associates Paul Cenci, P. E.-Principal Brian England-Principal Basic Terms CFM - Cubic Feet per Minute, volume (amount) of air being moved SP - Static Pressure, resistance
More informationB24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)
ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400
More informationZoning System Design Manual
Zoning Made Effortless 70-2321-03 Introduction The Concept of Zoning The basic principle of forced air zoning is to allow one HVAC system to be controlled by multiple thermostats, heating and cooling a
More informationScholar III Unit Ventilator
Scholar III Unit Ventilator 800 to 2000 CFM Models SVI 1000-2000 General Description The Scholar III unit ventilator is designed to provide comfortable, quiet and efficient heating and cooling for school
More informationBESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4
Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...
More information15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING
SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant
More informationJP380BVBB - GE 30" Patio Grill with Downdraft Venting System
Built-In Downdraft Modular Cooktop Dimensions (in inches) 3 6" Dia. 2-9/6 20-/2 29-7/8 9 6æ, ææ æ 2-/4 Built-In Downdraft Modular Cooktop Cabinet Dimensions (in inches) 6 9 20 C L 4 0-/2 eceptacle Location:
More informationSeries HF custom designed flange and insert heaters.
Page 1 - GENERAL INFORMATION A - INTRODUCTION 1 - GENERAL DESCRIPTION A Duct Heater is a self contained heater designed to be installed in the field in an air stream of a duct system, external to the air
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More information