1 Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns. MODELS: SCD: Supply ceiling diffuser. RCD: Return ceiling diffuser.

2 Linear Slot Diffusers : Frame and Curved deflection blades are made of extruded aluminum alloy 6063 to T6 heat treatment. Available with GI sheet to control air flow patterns. MODELS: SLD: Supply Linear diffuser. RLD: Return Linear diffuser

3 Linear Bar Grills : SAMA Linear bar grille " single deflection " is wall mounted grille, used as supply or return grille in cooling, heating or ventilation applications. The single deflections linear grille is composed of a set of fixed horizontal straight bars attached to frame, both manufactured from extruded aluminum sections. MODELS: SLBG: Supply linear bar grille. RLBG: Return linear bar grille. SLRG: Supply linear Register. RLRG: Return linear Register

4 Supply Air Grille & Registers : The single deflection air grill is composed of a set of deflecting blades mounted on a rectangular shaped frames. The double deflection air grille is composed two sets of deflecting blades mounted in two adjacent planes. The two sets of deflecting blades are mounted in such a way that one set is vertically mounted and the other set is horizontally mounted. The single and double deflection air grille are used for cooling, heating or air ventilation. MODELS: SAG D/D ( With Damper ) SAG S/D ( With Damper ) SAG D/D ( Without Damper ) SAG S/D (Without Damper )

5 Fixed Blade: SAMA fixed blade is composed of a set of horizontally mounted fixed blades that are made of extruded aluminum. MODELS: FBH FBV FBRV

6 Round Diffuser : Fully adjustable air discharge pattern horizontal vertical, for spot cooling, heating and ventilating application. Removable inner core assembly for easy installation. Aluminum construction. Standard color RAL9016. MODELS : SRCD: Supply Round Ceiling diffuser. RRCD: Return Round Ceiling diffuser.

7 Jet Diffuser : Aluminum construction with extruded aluminum frame. Adjustable core provide air discharge up to 30 degree from the mid position in any plane. Single element provide direct connection to round duct system. MODEL : JD: Jet diffuser.

8 Disc Valve : Air flow rate can be controlled by rotating the central disc. Central disc is fixed by locking nut. Face galvanized steel. Spindle and locking nut galvanized steel. MODELS : DV: Disc Valve.

9 Door Grille : SAMA Door grille composed of a set of horizontally V-shape blades mounted with fixed spacing to a frame called the fixed frame. MODELS : DG: Door Grille.

10 Egg Crate : SAMA Egg Crate frame made of extruded aluminum and core of square aluminum sheet standard color white powder coating to ( RAL 9016 or 9010 ). MODELS: EC: Egg Crate.

11 Fresh Air Intake & Exhaust Louvers: Air louvers is composed of a set of horizontal mounted fixed blades and inclined down 45 Spaced 35 mm or 50mm on center, blades and frame are manufactured from extruded aluminum Alloy ( 6063-t6 ) designed for both intake and exhaust opening.

12 Sand Trap Louver: SAMA sand trap louver manufactured for fresh air intake in HVAC systems, which are designed To separated large size sand particles at low air velocities thus avoiding excessive dust Loading performance for air filtration and moderate pressure drops at low air velocities.

13 Access Door Grilles : The frames are made of extorted aluminum alloy, access door grille core can be fabricate from fixed blade, egg crate and perforated sheets. standard color is white powder coating ( RAL 9016).

14 Access Door Duct SAMA manufactures Access Doors Duct that are designed for use in central air conditioning ductwork systems to provide access for resetting of Fire Dampers, Heaters, Filters or other maintenance works. The strong and robust construction of the access door guarantees low leakage of air even with high duct pressures. Double walled door panel with mineral wool insulation will act as better resistance for transfer of heat..

15 Volume Control Damper : Volume control damper is made of multi blades, parallel, and frame is flange type of Galvanized steel construction, hand locking quadrant is provided manual operation, Extended shaft and motor base is provided for motorized operation. the blades are mounted on nylon bushing and operated by external linkage.

16 Fire Dampers : Fire damper are made of 20 gauge galvanized steel blades are curtain type of gravity shutter without negatron closure spring for static operation or with stainless steel negatron spring for dynamic operation

17 Fire & Smoke Dampers : Combination fire & smoke damper meet the requirement of safety in HVAC system. FSD consist of a fire damper and smoke damper together as a single damper. FSD is used in HVAC system where a wall, floor or ceiling is celling is required to have both a fire and smoke damper. FSD close up on the detection of heat ( via duct temperature ) or smoke via ( via smoke detector ). FSD is available with electric heat devices instead of fusible links in regular fire damper.

18 Back Draft Damper : From light operations to heavy-duty industrial applications, SAMA provides the perfect back draft damper. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. The industrial grade back draft dampers offer rugged construction & heavy gage materials to with stand the high velocities & back pressure associated with heavy duty installations. SAMA has developed three types of Back Draft Dampers as following : 1. Light Back Draft Damper. 2. Back Draft Damper. 3. Pressure Relief Damper.

19 Variable Air Volume (VAV) * Variable Air Volume (VAV) is a type of heating, ventilating, and/or air-conditioning (HVAC) system. Unlike constant air volume systems, which supply a constant airflow at a variable temperature, VAV systems vary the airflow at a constant temperature. * Variable Air Volume Systems are the best way to zone especially in large buildings. A VAV system with the proper controls and set-up will help the building owner realize large savings in energy usage.

20 Sound Attenuators : Sound attenuators are constructed to the relevant of HVAC ducting work. Casing is 20 gauge galvanized steel. Baffle are made of 20 gauge galvanized steel perforated galvanized steel filled with sound obsorbing material. Flange from steel angle.

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY

AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY WWW.ANTALYA-AIRTECH.COM ANTALYA FACTORY 2 INTRODUCTION INTRODUCTION We are honored to introduce our firm ANTALYA AIR TECHNOLOGY FACTORY

More information

SECTION AIR OUTLETS AND INLETS

SECTION AIR OUTLETS AND INLETS SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.

More information

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today. FIRE & SMOKE DAMPERS Meeting tomorrow's requirements for fire and smoke protection today. LATEST TECHNOLOGY For more than 40 years Ruskin has led the HVAC industry in the manufacture of dampers and louvers.

More information

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser. SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:

More information

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15820) - AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors

More information

AIR DUCT ACCESSORIES

AIR DUCT ACCESSORIES SECTION 233300 - PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

SECTION DUCTWORK

SECTION DUCTWORK PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to

More information

Life Safety Dampers Selection and Application Manual

Life Safety Dampers Selection and Application Manual Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers August 2016 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER

More information

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions ISSUE A, MAY 2008 Hard Wired Damper Control Panels Systems 10, 11, & 12 Hard-Wired Systems Bespoke Systems Available Value Engineered Solutions Overview The Hard-Wired Control Panels On a number of projects

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems 233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section

More information

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

INSTALLATION DO S AND DON TS

INSTALLATION DO S AND DON TS 4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

SECTION DUCTWORK

SECTION DUCTWORK SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).

More information

Displacement Ventilation

Displacement Ventilation Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork. SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto

More information

Linear Floor Heaters

Linear Floor Heaters Linear Floor Heaters The Price Linear Floor Heater family provides ultimate flexibility in terms of style, performance, and ease of installation. Using room-side heat virtually eliminates the requirement

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED

More information

Ceiling diffusers. Type DLQL

Ceiling diffusers. Type DLQL X X testregistrierung Type Horizontal one-way air discharge Horizontal two-way air discharge Horizontal four-way air discharge Horizontal duct connection For horizontal one-way to four-way air discharge,

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2017 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,

More information

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION) GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION) February, 2017 Contents Clauses Page 1. Basic Concepts 1 2. Design Considerations 1 3. Car Parks Ventilation 2 4. Kitchen

More information

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS BYPASS TERMINAL UNITS DVAC, One Of The Premium Workshops Specialized in Duct Fabrication has Executed Several Projects (Residential, Governmental, Commercial, Industrial & Institutional). 2 BYPASS TERMINAL

More information

PDH & Professional Training

PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 PDH & Professional Training PDH Storm, by Engineers Edge, LLC CONTENTS 1. INTRODUCTION 1.1 GENERAL CRITERIA 1.2 DESIGN PROCEDURE

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers. VAV Diffusers lease refer to the rice Engineer s HVAC Handbook for more information on VAV Diffusers. Diffuser Types Ceiling Diffusers Conventional air distribution systems typically group several rooms

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

Convectors Steam / Hot Water November, 2009

Convectors Steam / Hot Water November, 2009 Convectors Steam / Hot Water 13-111.3 November, 2009 TABLE OF CONTENTS I. Model Nomenclature...3 II. Design Benefits... 4-5 III. Typical Piping Arrangements....6 IV. Correction Factors A. Steam...7 B.

More information

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2011 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

Fire dampers. For diverse applications

Fire dampers. For diverse applications . X X testregistrierung Fire dampers Type with fusible link for 72 C or 95 C CE compliant according to European regulations With TROXNETCOM as an option ATEX certification For diverse applications Rectangular

More information

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story

More information

DACC Health Sciences Building Air Handler Assessment/Study

DACC Health Sciences Building Air Handler Assessment/Study DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.

More information

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015 Peter McDonnell, PE, LEED AP BD+C McClure Engineering UL DAMPER TEST STANDARDS UL 555 - FIRE DAMPERS UL555S SMOKE DAMPERS UL555C CEILING

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers elevent ceiling diffusers Technical Selection Swirl, Jet, Louvred and Curved ceiling diffusers Paltech elevent Ceiling Diffusers are protected by: Australian Patent 0179430 + other patents pending Australian

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

Lenntech. Tel Fax

Lenntech. Tel Fax Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 MC Fluid Cooler Unmatched reliability Heavy-duty construction, high performance design and our five-year mechanical

More information

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small rectangular fire damper for the isolation of duct penetrations

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters 237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices

More information

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment

More information

AIR TERMINALS & DUCT HEATERS.

AIR TERMINALS & DUCT HEATERS. AIR TERMINALS & DUCT HEATERS. TABLE OF CONTENTS. 4 2 CAV AIR TERMINAL UNITS 3 BYPASS AIR TERMINAL UNITS 52 DIGITAL THERMOSTATS FOR AIR TERMINAL UNITS 2 3 VAV AIR TERMINAL UNITS 4 5 SINGLE DUCT PRESSURE

More information

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments, for a variety of installation situations, available in many different sizes

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-23 00 00 (October 2006) ---------------------------- Preparing Activity: USACE Superseding UFGS-23 00 00 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Chore-Time Fan Guide For Tunnel and Other Applications

Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time s Fiberglass and Galvanized Fans Provide Efficiency and Performance Diameters available through 54 Inches (137.2 cm) Chore-Time s TURBO

More information

The Corona air inlet TECHNICAL SPECIFICATIONS

The Corona air inlet TECHNICAL SPECIFICATIONS 710 The Corona air inlet Proper distribution of air in a house for animals can be a challenging task. The ventilation system should be able to maintain a perfect climate throughout the production cycle.

More information

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success. BLOWERS With over 70 years of experience and expertise our fans will ensure your projects are a success. ABOUT OUR PARTNERSHIP has been representing Chicago Blower Corporation (USA) since 2004, offering

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION BES-TECH TECHNOLOGY & SYSTEM INTEGRATION BES-TECH TECHNOLOGY & SYSTEM INTEGRATION DIGI-ACC Digi-ACC is a control kit for air cooled chiller systems, optimizing both chiller and pumps thereby reducing consumption

More information

+91-9582815184 Enviro Tech Industrial Products www.envirotechindustrialproducts.net We are recognized as a leading Manufacturer, Trader, Exporter and Supplier of high quality Clean Room Equipment, Air

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Facilitator Healthcare Systemair - Ventilation World Wide Systemair is a leading ventilation

More information

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments,

More information

CONDOR. Supply air ceiling QUICK FACTS

CONDOR. Supply air ceiling QUICK FACTS Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O

More information

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating. SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX010 November 2005 AXIAL POWER ROOF VENTILATORS Power Roof Ventilators Twin City Fan & Blower offers a wide variety of Power Roof Ventilators (PRVs). The PRVs have been

More information

and SHUTTERS Made to Work. Built to Last.

and SHUTTERS Made to Work. Built to Last. FANS and SHUTTERS Made to Work. Built to Last. VANGUARD PLUS Fan with HYFLO Shutter Chore-Time s VANGUARD PLUS Cone Fan provides a great combination of performance, features and value. Add Chore-Time s

More information

A. This Section includes air-handling units with coils for indoor installations.

A. This Section includes air-handling units with coils for indoor installations. SECTION 237313 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes air-handling units with coils for indoor installations. 1.2 SUBMITTALS A. Product Data: For each type of indoor air-handling unit

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance

More information

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will

More information

ATC Heating Devices. P. 1 ATC Heating Devices

ATC Heating Devices. P. 1 ATC Heating Devices ATC Heating Devices P. 1 ATC Heating Devices ATC Heating Devices Suspended water heater FWW The hot water heater is attached to a wall using brackets. The direction of air flow (upwards or downwards) is

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Agitation and Mixing

Agitation and Mixing Agitation and Mixing Agitation: Agitation refers to the induced motion of a material in a specified way, usually in a circulatory pattern inside some sort of container. Purpose is to make homogeneous phase.

More information

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form PART 1 GRAVITY CHUTES CHUTE DESIGN AND INSTALLATION INTAKE OPENINGS LIMITED ACCESS OFFSETS DIMENSIONS VENTING CONSTRUCTION

More information