AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY

Size: px
Start display at page:

Download "AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY"

Transcription

1 AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY

2 ANTALYA FACTORY 2

3 INTRODUCTION INTRODUCTION We are honored to introduce our firm ANTALYA AIR TECHNOLOGY FACTORY W.L.L." as a one of the leading Manufacture of HVAC products in middle east with a proven successful experience record in this field. ANTALYA are well equipped with the latest advanced technology in manufacturing systems to provide support facilities to stuff,including design,projects managements, start up through close monitoring of extensive quality control procedures, Tendering and reporting. ANTALYA is a manufacturing facility utilizing latest high technology in sheet metal fabrication machinery fleet with highly skilled team members to assure high precision and quality product that serve HVAC industry end users. We deals with a broad range of products predominantly air terminal devices such as grilles, diffusers and duct accessories. Our state of the art manufacturing facility located in BAHRAIN is equipped and employed with latest machineries and people having skill set in their respective field to quickly address the fluctuating yet large demand in HVAC field. If you are a consultant, designer, architect, contractor or an owner ANTALYA will make you sure to be your destination that you can rely on to make your building safer, more energy efficient and comfortable. We are always prepared to serve you and we will be highly honored if you provide us the occasion to render our service. General Manager 3

4 INDEX INDEX CONTENTS Introduction Chapter 1- Ceiling diffuser Chapter 2 - Linear slot diffuser Chapter 3 - Linear bar grille Chapter 4 - Air grille & register Chapter 5 - Round diffuser Chapter 6 - Jet diffuser Chapter 7 - Jet Nozzle diffuser Chapter 8 - Disc valve Chapter 9 - louvers Chapter 10 - Gravity chatter Chapter 11 - Perforated diffusers Chapter 12 - Volume damper Chapter 13 - Fire damper Chapter 14 - Sound attenuators Location & contact details PAGES

5 CEILING DIFFUSER CEILING DIFFUSER CHAPTER 1 ANTALYA AIR TECHNOLOGY

6 CEILING DIFFUSER CEILING DIFFUSERS Model AS-S1-01 AS-R1-01 AS-S2-01 AS-R2-01 AS-S3-01 AS-R3-01 AS-S4-01 AS-R4-01 Description Supply ceiling diffuser 1 way Return ceiling diffuser 1 way Supply ceiling diffuser 2 way Return ceiling diffuser 2 way Supply ceiling diffuser 3 way Return ceiling diffuser 3 way Supply ceiling diffuser 4 way Return ceiling diffuser 4 way Description: The square ceiling diffusers are available with multidirectional air flow pattern. The frame and cores are high quality extruded aluminum, the inner core of diffuser is fully removable for easy installation. The unit size for square ceiling diffuser increases in 3 increments beginning with 6 x6 as the smallest available. The opposite blade damper (O.B.D) fixed in diffuser frame is lever operated from the face of the unit. Suitable in ceiling with multi directional throws as required. Equalizing grid provided as option for proper air stream throw. Diffuser are also available with T-bar lay-in prefabricated panel of required sizes to meet with ceiling and installation. Standard finish for diffuser is white color. Damper in black color. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. NC RANGE: < 20 To < 40 SIZE CFM RANGE 6 X X X X X X X

7 CEILING DIFFUSER CEILING DIFFUSERS FOUR WAY THROW MODEL: AS-S4-01 Description: The frame and blades are of high quality extruded aluminum profiled construction with the advantages of corrosion resistance and rigidity. Diffusers shall be coned type with each cone manufactured by extruded aluminum louvered profiles or one piece die formed aluminum construction arranged in concentric cones to deflect air equally in four directions. Louvered type core is fixed to the frame with aluminum pins loaded with steel springs. Core can be easily removable and interchangeable to allow for maximum flexibility in installation, maintenance and damper adjustment. Damper is fixed rigidly to the frame by aluminum rivets. Fixing by spring clips as option. Damper blades are separated from its frame by nylon bushes Opposed blade damper is screw operated from the face opening of the diffuser after removing the internal core. Lever operated damper as option. Discharge air equally in four horizontal directions. Foam gasket is sealed around the back of the frame as option to avoid air leakage. Available in rectangular sizes as option. Suitable for flush mounting in lay in type ceiling. 7

8 CEILING DIFFUSER CEILING DIFFUSERS THREE WAY THROW AIR FLOW DATA 10

9 CEILING DIFFUSER CEILING DIFFUSERS FOUR WAY THROW AIR FLOW DATA 8

10 CEILING DIFFUSER CEILING DIFFUSERS THREE WAY THROW MODEL: AS-S3-01 Description: The frame and blades are of high quality extruded aluminum profiled construction with the advantages of corrosion resistance and rigidity. Diffusers shall be coned type with each cone manufactured by extruded aluminum louvered profiles or one piece die formed aluminum construction arranged in concentric cones to deflect air equally in three directions. Louvered type core is fixed to the frame with aluminum pins loaded with steel springs. Core can be easily removable and interchangeable to allow for maximum flexibility in installation, maintenance and damper adjustment. Damper is fixed rigidly to the frame by clips. Fixing by spring clips as option. Damper blades are separated from its frame by nylon bushes Opposed blade damper is screw operated from the face opening of the diffuser after removing the internal core. Lever operated damper as option. Discharge air equally in three horizontal directions. Foam gasket is sealed around the back of the frame as option to avoid air leakage. Available in rectangular sizes as option. Suitable for flush mounting in lay in type ceiling. 9

11 CEILING DIFFUSER CEILING DIFFUSERS TWO WAY THROW MODEL:AS-S2-01 Description: The frame and blades are of high quality extruded aluminum profiled construction with the advantages of corrosion resistance and rigidity. Diffusers shall be coned type with each cone manufactured by extruded aluminum louvered profiles or one piece die formed aluminum construction arranged in concentric cones to deflect air equally in two directions. Louvered type core is fixed to the frame with aluminum pins loaded with steel springs. Core can be easily removable and interchangeable to allow for maximum flexibility in installation, maintenance and damper adjustment. Damper is fixed rigidly to the frame by spring clips. Damper blades are separated from its frame by nylon bushes Opposed blade damper is screw operated from the face opening of the diffuser after removing the internal core. Lever operated damper as option. Discharge air equally in two horizontal directions. Foam gasket is sealed around the back of the frame as option to avoid air leakage. Available in rectangular sizes as option. Suitable for flush mounting in lay in type ceiling. 11

12 CEILING DIFFUSER CEILING DIFFUSERS TWO WAY THROW AIR FLOW DATA 12

13 CEILING DIFFUSER CEILING DIFFUSERS ONE WAY THROW MODEL:AS-S1-01 Description: The frame and blades are of high quality extruded aluminum profiled construction with the advantages of corrosion resistance and rigidity. Diffusers shall be coned type with each cone manufactured by extruded aluminum louvered profiles or one piece die formed aluminum construction arranged in concentric cones to deflect air equally in one direction. Louvered type core is fixed to the frame with aluminum pins loaded with steel springs. Core can be easily removable and interchangeable to allow for maximum flexibility in installation, maintenance and damper adjustment. Damper is fixed rigidly to the frame by spring clips. Damper blades are separated from its frame by nylon bushes Opposed blade damper is screw operated from the face opening of the diffuser after removing the internal core. Lever operated damper as option. Discharge air equally in one horizontal direction. Foam gasket is sealed around the back of the frame as option to avoid air leakage. Available in rectangular sizes as option. Suitable for flush mounting in lay in type ceiling. 13

14 CEILING DIFFUSER CEILING DIFFUSERS ONE WAY THROW AIR FLOW DATA 14

15 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER CHAPTER 2 ANTALYA AIR TECHNOLOGY

16 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER Model AS-SLD-02 AS-RLD-02 AS-SLD1-02 AS-RLD1-02 Description Supply Linear Slot Diffuser WITH 3/4 slot width Return Linear Slot Diffuser WITH 3/4 slot width Supply Linear Slot Diffuser WITH 1 slot width Return Linear Slot Diffuser WITH 1 slot width Product Description: The linear slot diffuser with deflection blades and control damper ( Hit and Miss type) is fabricated from high quality extruded aluminum. The fully adjustable deflection blades allow for the air pattern to be control along the ceiling straight down or at some intermediate settings, The deflection blades are designed so that when in close position air pressure tends to form a tight seal. The standard slot widths are ¾ and 1. The volume control damper consists of two strips one fixed and another movable, which also act as an equalizing grid.. The airflow rate can be varied without changing the air pattern by use of volume control damper attached to rear side of the diffuser. The airflow rate can be reducing by off setting the holes in hit and miss damper. Linear slot diffusers are also available in curved shapes but with out damper. Suitable in ceiling for horizontal and vertical discharge. Standard color is white for frame and blades. Hit and miss damper and deflection blades are in black color. Other colors available in request. NC RANGE: < 20 To < 40 No. of Slots CFM RANGE/FT

17 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER End Cap Arrangements. 17

18 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER Linear Slot Supply Diffuser Featuring Fully Adjustable Deflection Blades. ONE - WAY TWO - WAY VIRTICAL AND HORIZONTAL 18

19 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER * Engineering Data 19

20 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER - Performance Data for supply linear slot diffuser 3/4 slot width Model: AS-SLD-02 20

21 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER - Performance Data for supply linear slot diffuser 1 slot width Model: AS-SLD

22 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER - Performance Data for return linear slot diffuser 3/4 slot width Model: AS-RLD-02 22

23 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER - Performance Data for return linear slot diffuser 1 slot width Model: AS-RLD

24 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER DIMENTIONS NO OF SLOT SLOT WIDTH MM NECK DIM. MM FACE DIM. MM

25 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER Curve Linear Slot Diffuser engineering data 25

26 LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER Metered corners: 26

27 LINEAR BAR GRILLE LINEAR BAR GRILLE CHAPTER 3 ANTALYA AIR TECHNOLOGY

28 LINEAR BAR GRILLE LINEAR BAR GRILL Model AS-SBG0-03 AS-RBG0-03 AS-SBG1-03 AS-RBG1-03 Description Supply Linear Bar Grille 0-1/4 Return Linear Bar Grille 0-1/4 Supply Linear Bar Grille 0-1/8 Return Linear Bar Grille 0-1/8 Product Description: The frame and blades are fabricated from high quality extruded aluminum. The blades available with 0 deflection with a uniform distance of 1/2 in between. The standard depth of blade for 0 is ¾ resulting in uniform and non turbulent air stream throws. The mullion bars across the blades provide additional strength to prevent grill from bending. The opposed blade damper attached to the grill frame is lever operated through the face of the unit. Linear bar grilles are also available in curved shapes with damper for wall mountings. The grilles are suitable for ceiling, wall and console mounting for heating, ventilating and cooling applications. Standard finish is white color for frame and blades. Damper in black color. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. NC RANGE: < 20 To < 40 Nominal Width CFM RANGE/FT

29 LINEAR BAR GRILLE LINEAR BAR GRILL PERFORMANCE DATA FOR AS-SBG0-03 1/4 BARS - 1/2 SPACING - 0 DEG 29

30 LINEAR BAR GRILLE LINEAR BAR GRILL PERFORMANCE DATA FOR AS-SBG1-03 1/8 BARS - 1/2 SPACING - 0 DEG 30

31 LINEAR BAR GRILLE LINEAR BAR GRILL SUPPLY AND RETURN LINEAR BAR GRILL METERD CORNERS 31

32 LINEAR BAR GRILLE LINEAR BAR GRILL CURVE LINEAR BAR GRILL ENGINEERING DATA 32

33 AIR REGISTERS & GRILLES CHAPTER 4 ANTALYA AIR TECHNOLOGY

34 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Model AS-SRH4-ID AS-SGH4-ID AS-SRH4-IID AS-SGH4-IID AS-SRV4-ID AS-SGV4-ID AS-SRV4-IID AS-SGV4-IID AS-RGH4 AS-RRH4 AS-RGV4 AS-RRV4 Description Supply H Register Single Deflection Supply H Grille Single Deflection Supply HF Register Double Deflection Supply HF Grille Double Deflection Supply V Register Single Deflection Supply V Grille Single Deflection Supply VF Register Double Deflection Supply VF Register Double Deflection Return H grille 45 fixed blade Return H register 45 fixed blade Return V grille 45 fixed blade Return V register 45 fixed blade H: Horizontal face, V: Vertical Product Description: Fabrication of frame and blades are from high quality extruded aluminum, the frames are equipped with PVC bushings to assemble the blades, hence eliminating corrosion and vibration. The blades are airfoil in design. The opposite blade damper (O.B.D) attached to the supply & Return register can be easily adjusted by operating through the face of the unit. Suitable for high side wall, soffit or duct mounting for heating, ventilating and cooling applications. Standard finish is white color for frame and blades. Damper in black color. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. 34

35 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SRH4-ID- SINGLE DIFFLECTION SUPPLY REGISTER WITH HORIZOTAL ADJUSTABLE BLADES AND DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with pvc bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. 35

36 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SGH4-ID- SINGLE DIFFLECTION SUPPLY GRILLE WITH HORI- ZOTAL ADJUSTABLE BLADES WITH OUT DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with PVC bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Painted under electrostatic polyester powder coated system. Other colors available in request. 36

37 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SRH4-IID DOUBLE DIFFLECTION SUPPLY REGISTER WITH HORIZO- TAL FACE AND VERTICAL REAR ADJUSTABLE BLADES WITH DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with pvc bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. 37

38 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SGH4-IID DOUBLE DIFFLECTION SUPPLY GRILL WITH HORIZOTAL FACE AND VERTICAL REAR ADJUSTABLE BLADES WITH OUT DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with pvc bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. 38

39 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SRV4-ID- SINGLE DIFFLECTION SUPPLY REGISTER WITH VERTICAL ADJUSTABLE BLADES AND DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with pvc bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. 39

40 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SGV4-ID- SINGLE DIFFLECTION SUPPLY GRILLE WITH HORIZOTAL ADJUSTABLE BLADES WITH OUT DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with PVC bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Painted under electrostatic polyester powder coated system. Other colors available in request. Suitable for high sidewall, soffit or duct mounting, for heating, ventilating and cooling applications. 40

41 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SRV4-IID DOUBLE DIFFLECTION SUPPLY REGISTER WITH VERTICAL FACE AND HORIZOTAL REAR ADJUSTABLE BLADES WITH DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with pvc bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. 41

42 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-SRGV4-IID DOUBLE DIFFLECTION SUPPLY GRILLE WITH VERTICAL FACE AND HORIZOTAL REAR ADJUSTABLE BLADES WITH OUT DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. Frame has a typical wall thickness of 1/16 and is separated from the blades with pvc bushings. This method of assembly eliminate corrosion & vibration. The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced 3/4 on center. Deflection of blades are easily set without use special tools. The unit achieves an effective area of 80% with the blades set at 0 pattern thus eliminating high velocity and pressure drop at grille face. Wider deflection with reduced throw may be achieved at the 22 ½ and 45 blade sitting with only slightly increased noise levels. Standard finish white color for frame and blades,. Painted under electrostatic polyester powder coated system. Other colors available in request. 42

43 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers engineering data 43

44 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers performance data 44

45 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers performance data 45

46 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers performance data 46

47 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers performance data 47

48 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers performance data 48

49 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers performance data 49

50 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES Supply air grilles and registers installation data 50

51 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-RGH4 SINGLE DIFFLECTION RETURN GRILLE WITH HORIZONTAL BLADES WITH OUT DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. The Frame has a typical wall thickness of 1/16 The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, set in a fixed position at an angle of 45 and spaced 3/4 on center. Standard finish white color for frame and blades. Painted under electrostatic polyester powder coated system. Other colors available in request. Suitable for high sidewall, soffit or duct mounting, for heating, ventilating and cooling applications. 51

52 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-RRH4 SINGLE DIFFLECTION RETURN REGISTER WITH HORIZON- TAL BLADES AND DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. The Frame has a typical wall thickness of 1/16 The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, set in a fixed position at an angle of 45 and spaced 3/4 on center. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. Suitable for high sidewall, soffit or duct mounting, for heating, ventilating and cooling applications. 52

53 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-RGV4 SINGLE DIFFLECTION RETURN GRILLE WITH VERTICAL BLADES WITH OUT DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. The Frame has a typical wall thickness of 1/16 The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, set in a fixed position at an angle of 45 and spaced 3/4 on center. Standard finish white color for frame and blades. Painted under electrostatic polyester powder coated system. Other colors available in request. Suitable for high sidewall, soffit or duct mounting, for heating, ventilating and cooling applications. 53

54 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES AS-RRH4 SINGLE DIFFLECTION RETURN REGISTER WITH VERTICAL BLADES AND DAMPER Product Description: The frame & blades are extruded aluminum alloy and are polyester coated with a white finish. The Frame has a typical wall thickness of 1/16 The frame mounting holes are dimpled, allowing for counter-sunk fastener head appearance. All blades are airfoil in design, set in a fixed position at an angle of 45 and spaced 3/4 on center. Opposed blade damper (OBD) operator is easily adjusted through face with a screw driver. Standard finish white color for frame and blades, Damper in black color. Painted under electrostatic polyester powder coated system. Other colors available in request. Suitable for high sidewall, soffit or duct mounting, for heating, ventilating and cooling applications. 54

55 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES RETURN AIR GRILLES AND REGISTERS PERFORMANCE DATA 55

56 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES RETURN AIR GRILLES AND REGISTERS PERFORMANCE DATA 56

57 AIR REGISTERS & GRILLES AIR REGISTERS & GRILLES INSTALLATION DETAILES 57

58 AIR REGISTERS & GRILLES NOTES

59 ROUND DIFFUSER ROUND DIFFUSER CHAPTER 5 ANTALYA AIR TECHNOLOGY

60 ROUND DIFFUSER ROUND DIFFUSER AS-RD-5 Model AS-SRD-5 AS-RRD-5 Description Supply Round Ceiling Diffuser Return Round Ceiling Diffuser Description: Frame and inner cones of round ceiling diffuser is made of high quality aluminum sheet construction with the advantages of corrosion resistance and rigidity. Inner cones fixed centrally to the frame. Cones can be taken out by pushing inward, turn around and pull down. This provides easy installation, maintenance and access to the duct. Radial, opposed blade damper is fixed to the frame by rivets. Damper can be operated by screw through diffuser face. Foam gasket is sealed around the back of the frame as option to avoid air leakage. Can be used for ceiling or exposed duct mounting. Standard finishes: Aluminum construction with white powder coated color finish (RAL 9010). Steel construction with white powder coated finish (RAL9010) Powder coated color finish as per other RAL color codes available as option. Same as ARD, but with steel construction. 60

61 ROUND DIFFUSER ROUND DIFFUSER PERFORMANCE DATA 61

62 ROUND DIFFUSER NOTES

63 JET DIFFUSER JET DIFFUSER CHAPTER 6 ANTALYA AIR TECHNOLOGY

64 JET DIFFUSER JET DIFFUSER AS-JD-6 Model AS-JD6 AS-JDS6 AS-JDS6-M Description Jet diffuser std. construction Jet diffuser Single element Jet diffuser Multi Elements NC RANGE: < 20 To < 40 SIZE CFM RANGE 8 DIA DIA DIA Jet diffuser are air terminal outlets best suitable for high volume and long throw applications. The turbo nozzle and inner concentric rings the turbo nozzle and inner concentric rings (cores) are aluminum alloy with high quality construction and the mounting panel of jet Diffusers is 20 gauge high quality G.I Steel the inner concentric ring s of jet can be adjusted in both vertical and horizontal positions, which makes it suitable for both sidewall and ceiling installation. The control of inner concentric rings by means of a smooth pivot linkage bolt also known as universal ball joint mounted in a three leg bracket connected to the turbo nozzle one tow three or four jet diffuser elements per panel can be selected standard finish is white, painted under electrostatic polyester powder coated system. Other available on request. The polyester of highest quality is used to enhance the appearance of the units. Suitable for place such as a airport, auditorium, long entrance walk ways ( Horizontal discharge) gymnasium and swimming pools ( vertical discharge) etc. 64

65 JET DIFFUSER JET DIFFUSER STANDARD AS-JD6 MODEL AS-JD6-8 AS-JD6-10 AS-JD6-12 AS-JD6-14 AS-JD6-16 AS-JD6-18 SIZE (INCHES) 8" Ø 10" Ø 12" Ø 14" Ø 16" Ø 18" Ø A B C D NO. OF RINGS 1 to 2 1 to 3 1 to 4 1 to 5 1 to 6 1 to 7 65

66 JET DIFFUSER JET DIFFUSER STANDARD AS-JD6 MODEL AS-JDS6-8 AS-JDS6-10 AS-JDS6-12 AS-JDS6-14 AS-JDS6-16 AS-JDS6-18 DCUT SIZE SQUARE WXH ROUND Ø 10"X10" 10" Ø 12"X12" 12" Ø 14"X14" 14" Ø 16"X16" 16" Ø 18"X18" 18" Ø 20"X20" 20" Ø A B Ø E

67 JET DIFFUSER JET DIFFUSER STANDARD AS-JD6 MODEL AS-JDS6-8-2M AS-JDS6-8-3M AS-JDS6-8-4M SIZE X QTY 8" X 2 8" X 3 8" X 4 A B C AS-JDS6-10-2M AS-JDS6-10-3M AS-JDS6-10-4M 10" X 2 10" X 3 10" X AS-JDS6-12-2M AS-JDS6-12-2M AS-JDS6-12-2M 12" X 2 12" X 3 12" X AS-JDS6-14-2M AS-JDS6-14-3M AS-JDS6-14-4M 14" X 2 14" X 3 14" X AS-JDS6-16-2M AS-JDS6-16-3M AS-JDS6-16-4M 16" X 2 16" X 3 16" X AS-JDS6-18-2M AS-JDS6-18-3M AS-JDS6-18-4M 18" X 2 18" X 3 18" X

68 JET DIFFUSER JET DIFFUSER STANDARD AS-JD6 PERFORMANCE DATA 68

69 JET NOZZLE DIFFUSER JET NOZZLE DIFFUSER CHAPTER 7 ANTALYA AIR TECHNOLOGY

70 JET NOZZLE DIFFUSER JET NOZZLE DIFFUSER AS-JN-7 MODEL AS-JN-7-8 AS-JN-7-10 AS-JN-7-12 AS-JN-7-8A AS-JN-7-10A AS-JN-7-12A SIZE (INCHES) 8" Ø 10" Ø 12" Ø 8" Ø 10" Ø 12" Ø THROW 10M CFM NC CFM M NC AIR VELOCITY M/S Product Description The turbo nozzle and rings (cores) are aluminum alloy with high quality construction. Jet nozzles are designed to supply air for long distance throw application jet nozzles are used in critical areas such as concert halls, theaters, airports, museums, malls, sport halls, etc.. Direction of the air stream can be easily adjusted by hand with in a range of +/-30. intended for installation in a connection box, sidewall areas. Standard finish is white painted under electrostatic polyester powder coated system, other colors are available on request. 70

71 JET NOZZLE DIFFUSER JET NOZZEL DIFFUSER AS-JN-7 PERFORMANCE DATA 71

72 JET NOZZLE DIFFUSER JET NOZZEL DIFFUSER AS-JN-7 INSTALLATION DETAILS 72

73 DISC VALVE DISC VALVE CHAPTER 8 ANTALYA AIR TECHNOLOGY

74 DISC VALVE DISC VALVE Disc valves are used as an alternative to ceiling diffuser. They are most commonly used for the purpose of ventilation. The air flow through the disk valve can be adjusted by rotating the disc clockwise or anticlockwise. The rotation changes the free area between the disc and the frame. Disc valves are preferred by many architects and building owners for toilets, bathrooms and ventilation in damp areas due to its simplistic yet aesthetic appearance. The sizes starts from 80mm up to 200mm Diameter. The fixing is very simple. Description: Frame and disc is made of high quality galvanized steel sheet construction with powder coated to RAL colors. Disc is attached to the frame by threaded rod. Air flow can be adjusted by regulating the cone up or down Foam gasket is sealed around the back of the frame as option to avoid air leakage. These valves can be used for supply, exhaust and ventilation applications. Air master disc valves are best suited to air distribution systems handling relatively low air flow rates within small circular duct work. Can be mounted in wall, ceiling or exposed air ducts with mounting rings. Recommended for exhaust of greasy and damp air in damp areas such as toilets, bathrooms and kitchens. 74

75 DISC VALVE DISC VALVE Model AS-DX8-4 AS-DX8-6 AS-DX8-8 Description DISC VALVE SIZE: 4 Ø DISC VALVE SIZE: DIA. 6 Ø DISC VALVE SIZE: DIA. 8 Ø 75

76 DISC VALVE DISC VALVE DISC VALVE AS-DX8-4 DISC VALVE AS-DX8-6 DISC VALVE AS-DX8-8 CFM: Cubic feet per minutes SP.: Static Pressure inches of water NC: Sound pressure levels 76

77 LOUVERS LOUVERS CHAPTER 9 ANTALYA AIR TECHNOLOGY

78 LOUVERS FRESH AIR LOUVER AS-FAL-9 Model AS-FAL-D-9 AS-FAL-9 Description Fresh air louver with damper Fresh air louver with out damper Product Description: The fresh air louver is device with unique choice and highly recommended for ventilating and transfer of air in any place. The frame and blades of fresh air louver are fabricated from high quality extruded aluminum. The blades are spaced 3 on center and are set at 45 deg. Fixed in horizontal position. An expanded aluminum screen generally known as bird screen is attached to the interior face of the louver. The purpose of this screen is to prohibit birds from going inlets. An optional wire mesh can also be added as insect screen to prohibit insects from interring inside the inlets. Optional aluminum filter 1 thick with handle (fully removable and washable) can be provide to protect the sand particles from going inlet of louver. Bigger sizes of fresh air louver are inserted in between vertically with (T) tee bar to support and strengthen the frame. Standard color is white for frame and blades of the louver. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. 78

79 LOUVERS FRESH AIR LOUVER * Performance Data and selection * To Calculate FREE AREA for any size: the approximate free area in square feet can be calculated by using the formula below: Free Area = (0.5H )*(W-0.10) W= Width in feet, H= Height in feet To calculate the air volume (CFM) multiply the area factor by the velocity. CFM = Free Area x Free Area Velocity. Free Area Velocity can be measured with a rotating vane anemometer. 79

80 LOUVERS FRESH AIR LOUVER INSTALLATION DETAILS 80

81 LOUVERS FRESH AIR LOUVER FRESH AIR LOUVER ASSEMBLY OPTIONS: opposed blade manual volume damper. Opposed blade motorized volume damper through actuator Washable aluminum filter (1 or 2 ) GI duct bend or MS Steel angle as at the end of assembly or (S slip - C clip) or plain duct 81

82 LOUVERS SAND TRAP LOUVER AS-STL-9 Face Area Velocity (fpm) Pressure Drop (in. w.g.) Product Description sand trap louvers are specially designed to separated the sand and dust from the air. It is effective and necessary to apply for ventilations and inlet ducts of air handling units. As the assembly comes with complete aluminum extruded profiles unit, it is corrosion resistant and suitable for different weather conditions. Sand trap louvers can be supplied with filters and dampers as optional. Sand trays with handle for collection of sand can be provided and this sand tray can be subjected for periodical cleaning to make the tray empty.. Louvers in more height from ground level can be provided with sand chute to make the sand particles continues fall. An optional aluminum screen can be provided interior face of the louver to protect birds from going inlet. An optional wire mesh can also be added as insect screen to prohibit insects from interring inside the inlets. Optional aluminum filter 1 thick with handle ( fully removable and washable) with vcd and duct assembly can be provided. Bigger sizes of sand trap louver are inserted in between horizontally and additional frame channel also known as joint connector if required or over request. Standard color is white for frame and blades of the louver. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. 82

83 LOUVERS SAND TRAP LOUVER Product Description: The sand trap louver is device used for sandy areas to separate from intake air The frame and blades are fabricated from high quality extruded aluminum. Provided with self emptying sand drain holes from the base. An optional wire mesh can also be added as insect screen to prohibit insects from interring inside the inlets. Optional aluminum filter 1 thick with handle (fully removable and washable) can be provide to protect the sand particles from going inlet of louver. Standard color is white for frame and blades of the louver. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. 83

84 LOUVERS SAND TRAP LOUVER 84

85 GRAVITY SHUTTER GRAVITY SHUTTERS CHAPTER 10 ANTALYA AIR TECHNOLOGY

86 GRAVITY SHUTTER GRVITY SHUTTER Model: AS-GSH-10 Horizontal operable pressure relief shutter Product Description: The horizontal operable shutter which operates to equalize the pressure across it. The frame and blades are fabricated from high quality extruded aluminum. The frame has typical wall thickness of 1/16 and is separated from the movable blades by extruded rigid PVC track, which is riveted to and becomes an integral part of the frame. A 1/8 thick, 3/8 wide foam tape installed on blade where they overlap to insure a good seal and to reduce noise. Each shutter is carefully designed to equalize the pressure in such areas as a compressor or fan room with the outside. The blades are designed and positioned in sush a way that if the pressure in the room increase the blades automatically lift and open relieving the pressure in the room. When the room pressure is normalized the blades drop to the closed position by gravity. This devices are also employed at the end of the exhaust ducts where they would open when the exhaust fan was turned on and would close when the fan was turned off. Standard color is white for frame and blades of the louver. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the 86

87 GRAVITY SHUTTER GRVITY SHUTTER Model: AS-GSH-D-10 Horizontal operable pressure relief shutter (DUCT MOUNTED) Product Description: The horizontal operable shutter which operates to equalize the pressure across it. The frame and blades are fabricated from high quality extruded aluminum. The frame has typical wall thickness of 1/16 and is separated from the movable blades by extruded rigid PVC track, which is riveted to and becomes an integral part of the frame. A 1/8 thick, 3/8 wide foam tape installed on blade where they overlap to insure a good seal and to reduce noise. Each shutter is carefully designed to equalize the pressure in such areas of the duct, where the pressure in the duct has to be maintained. The blades are designed and positioned in such a way that if the pressure in the duct increases the blades automatically lift and open relieving the pressure in the room. When the duct pressure is normalized, the blades drop to the closed position by gravity. This devices are also employed at the end of the exhaust ducts where they would open when the exhaust fan was turned on and would close when the fan was turned off. In a multi-unit instalation will prevent back draught through a non-operating unit. 87

88 GRAVITY SHUTTER GRVITY SHUTTER Performance data 88

89 PERFORATED DIFFUSER PERFORATED DIFFUSERS CHAPTER 11 ANTALYA AIR TECHNOLOGY

90 PERFORATED DIFFUSER PERFORATED CEILING DIFFUSER AS-PCD-11 Model AS-SPCD-14 Description Perf. Supply Ceiling Diffuser AS-RPCD-14 Perf. Return Ceiling Diffuser NC RANGE: < 20 To < 40 Module Size: 12 x12 Squar e Neck CFM Round Neck CFM Product Description 5 DIA X DIA X DIA NC RANGE: < 20 To < 40 Module Size: 24 X24 Square CFM Round CFM 6 X DIA X DIA X DIA X DIA X DIA X DIA X DIA Perforated face supply ceiling diffusers in adjustable air pattern deflectors in (1, 2. 3 and 4 way), volume control damper and adaptor with square or round neck. The frame and blades round neck. The frame and blades in high quality extruded aluminum and the perforated faceplate is SNAP- IN type, removable faceplate, and gives easy access to control deflectors or damper. Air pattern control is comprised of individually adjustable angle curved deflectors, capable of production fully controlled air direction for grater performance and efficiency. All internal portions of diffuser are non-reflective. Perforated ceiling diffusers are designed for heating, cooling and ventilating applications. Standard finish is white color for frame, blades and perforated face. Damper and adaptor in black color. Other colors available on request. Painted under electrostatic polyester powder coated system. the polyester powders of highest quality are used to enhance the appearance of units. 90

91 PERFORATED DIFFUSER PERFORATED CEILING DIFFUSER PERFORMANCE DATA 91

92 PERFORATED DIFFUSER PERFORATED CEILING DIFFUSER PERFORMANCE DATA 92

93 PERFORATED DIFFUSER PERFORATED CEILING DIFFUSER PERFORMANCE DATA 93

94 PERFORATED DIFFUSER PERFORATED CEILING DIFFUSER INSTALLATION DETAILES 94

95 VOLUME DAMPER CHAPTER 12 ANTALYA AIR TECHNOLOGY

96 VOLUME CONTROL DAMPER Manual Volume Control Dampers Model : AS-VCD-12 AS- Construction: Frame: High quality Galvanized Steel sheet of thickness 1.2mm as standard. Frame Size: 125mm depth and standard flange height of 25mm. Blades: Single skinned 3-V type G.I blade of 1.2mm thickness. Bushings: Self-lubricating nylon bushings. Blade stopper: G.I angle of thickness 0.7mm. Handle: Galvanized Steel locking hand quadrant. Description Volume Control damper is widely used in heating, ventilation and air-conditioning applications (HVAC Damper) in order to maintain or control the air volume inside the duct. These dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type depending on the requirement. Volume control damper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. ANTALYA provides several types of volume control dampers to choose from. ANTALYA G.I volume control damper is a type of HVAC Damper whose frame and blade is made of high quality G.I sheets. 96

97 VOLUME CONTROL DAMPER Manual Volume Control Dampers * RECTANGULAR VOLUME DAMPER MODEL: AS-VCD-12 Model AS-VCDS-12 AS-VCDP-12 AS-VCDO-12 AS-VCDM-12 Description VCD Single Blade VCD Parallel Blade VCD Opposed Blade VCD W/Motor Face Area Velocity (fpm) Pressure Drop (in. wg.) VD - OP VD PB Product Description Volume and control damper are best prime device to control the flow of air in HVAC system ducts. Dampers are available in single and multi blades. Further multi blades are classified in operation for parallel blades and opposed blades volume control dampers. For all types of dampers the frame is fabrication of 4 x1 x16 gauge high quality mill galvanized steel channels with welded corners and blades are of 16 gauge high quality mill galvanized steel reinforced with 3 longitudinal structurally designed Vees. The blades are or (motorized) operated with self-oiling bronze bushings for smooth and noiseless operation. The damper are manual/actuator control (also known as motorized volume control damper) in manual control it is dial regulator for small/ big size of damper and similarly actuator of lower/higher capacities are used for motorized volume control damper. For damper ranging in big sizes frame channels are added in between vertically/horizontally to make the complete assembly rigid and stable. 97

98 VOLUME CONTROL DAMPER Manual Volume Control Dampers * ROUND VOLUME DAMPER MODEL: AS-RVD-12 Model Description AS-RVDL-12 Round VCD - Low pressure AS-RVDH-12 Round VCD - High pressure SIZE CFM RANGE 8 dia dia dia dia dia * Approximate Pressure Drop Product Description Volume and control damper are best prime device to control the flow of air in HVAC system round ducts. Generally the round volume control dampers are classified as low pressure and high pressure volume control depending upon the velocity of flow in the round ducts. The damper round frame and disc ( blade) is fabricated from high quality 16 gauge mill galvanized steel. The Damper blade is operated by adjusting the handle of rapid damper regulator set for low pressure volume control damper and dial regulator/ quadrant regulator for high pressure volume control damper depending upon it size. High pressure volume control damper can also be subjected to actuator control if required. Actuator of higher / lower capacities will be used upon the area of damper. The selection of actuator types of volume control dampers (single blade, parallel blade, opposed blade and round etc.) depends upon their respective areas. For all types of motorized volume control dampers. Generally modulating type ON/OFF (three position) actuators are used. The capacity (Torque) of actuator in Nm (Newton-meter) should be verified from manufacture s data before selection. 98

99 VOLUME CONTROL DAMPER Manual Volume Control Dampers PERFPRMANCE CHART 99

100 VOLUME CONTROL DAMPER Manual Volume Control Dampers HOW TO SELLECT VOLUME DAMPER HOW TO SELECT THE VOLUMM DAMPER Bearing Fixing Operation Size Manual Locking Plain Undrilled Quadrant (Standard) Nylon (Standard) (Standard) Motor Shaft (Specify size in mm) Factory Fitted Motor Brass (Option) Bolt Fixing (Motor Type and Voltage Duct Width x Duct Height to be Confirmed at time OR DIAMETER FOR ROUND VD C-Cleats of Order) 100

101 FIRE DAMPER FIRE DAMPER CHAPTER 13 ANTALYA AIR TECHNOLOGY

102 FIRE DAMPER FIRE Dampers FD-ANT-13 Model FD-ANT-13A FD-ANT-13b FD-ANT-13A/B-S Description Fire Damper with out sleeve And blades in air stream Fire Damper with out sleeve And blades above air stream Fire Damper with sleeve FD-ANT-13A/B-R Fire Damper Round Collar Product Description Fire Dampers are the most commonly used devices in HVAC system duct for protection of fire from further expansion during fire accidents. The frame is roll formed in fabrication from high quality 20 gauge mill galvanized steel and blades are inter locking type 24 gauge mill galvanized steel. The fusing temp of fusible link is 165 F and UL listed. Other fusing temperature are available on request. Operation blades is by means of stainless steel negator closure spring. The damper process 91-95% free area. With blades IN air stream and this type of dampers are generally called as A type. And the dampers fabricated for blade out of air stream to give 100% free area in both square and rectangular duct are called class B types fire damper. The same can be appreciated in round/oval ducts and the above, S type fire dampers can be provided with extended duct with sleeves. B type fire dampers can also be provided with sleeve and access door. All above fire dampers are for 3 hours fire rating standard to specifications from UL 555 std.) and all fire dampers can be subjected to both vertical and horizontal position in duct mountings as per the duct position. 102

103 FIRE DAMPER FIRE Dampers Fire Damper 3 Hrs Rated Without Sleeve Model Construction Blade Fire Rating Max Velocity Max Pressure Airflow Direction Fusible Link Installation : FD-ANT-13A (A- Blades in Air Stream) : Galvanized Steel : Curtain Type : 3 Hrs. as per UL-555 : 2000FPM : 4 w.g : Either : 165 F (74 C) : V/H ANTALYA FD-ANT-10A Series Curtain blades Fire damper is high performance UL-555 classified with 3 Hrs Fire rating. May be installed vertically or horizontally for static application and vertically ( with blades running horizontally) for dynamic application and is rated for fire resistance in either direction. A 103

104 FIRE DAMPER FIRE Dampers Fire Damper 3 Hrs Rated Without Sleeve Model Construction Blade Fire Rating Max Velocity Max Pressure Airflow Direction Fusible Link Installation : FD-ANT-13B (B Blade Above Air Stream) : Galvanized Steel : Curtain Type : 3 Hrs. as per UL-555 : 2000FPM : 4 w.g : Either : 165 F (74 C) : V/H ANTALYA FD-ANT-10B Series Curtain blades Fire damper is high performance UL-555 classified with 3 Hrs Fire rating. May be installed vertically or horizontally for static application and vertically ( with blades running horizontally) for dynamic application and is rated for fire resistance in either direction. B 104

105 FIRE DAMPER FIRE Dampers Fire Damper 3 Hrs Rated With Sleeve Model Construction Blade Fire Rating Max Velocity Max Pressure Airflow Direction Fusible Link Installation : FD-ANT-13A/B-S (B Blade Above Air Stream) : Galvanized Steel : Curtain Type : 3 Hrs. as per UL-555 : 2000FPM : 4 w.g : Either : 165 F (74 C) : V/H ANTALYA FD-ANT-10A/B-S Series Curtain blades Fire damper is high performance UL-555 classified with 3 Hrs Fire rating. May be installed vertically or horizontally for static application and vertically ( with blades running horizontally) for dynamic application and is rated for fire resistance in either direction. 105

106 FIRE DAMPER FIRE Dampers Round Fire Damper 3 Hrs Rated Model : FD-ANT-13A/B -R (A- Blades in Air Stream; B- Above Air Stream) Construction Blade Fire Rating Max Velocity Max Pressure Airflow Direction Fusible Link Installation : Galvanized Steel : Curtain Type : 3 Hrs. as per UL-555 : 2000FPM : 4 w.g : Either : 165 F (74 C) : V/H ANTALYA FD-ANT-10A/B-R Series Curtain blades Fire damper is high performance UL-555 classified with 3 Hrs Fire rating. May be installed vertically or horizontally for static application and vertically ( with blades running horizontally) for dynamic application and is rated for fire resistance in either direction. 106

107 FIRE DAMPER FIRE Dampers Model of Fire Damper FD-A/D-13A-S/B-S/R Module Width x Height SIZE LIMETA- TION Mounting Position A Blades in Air stream Single 4 x4 V/H B Single 36 x 36 V/H F Blades in above Air stream Mounting Frame Multiple 72 x 72 V/H S Sleeve Multiple 144 x 96 V/H R Round Spigot 107

108 FIRE DAMPER NOTES

109 SOUND ATTENUATOR SOUND ATTENUATOR CHAPTER 14 ANTALYA AIR TECHNOLOGY

110 SOUND ATTENUATOR SOUND ATTENUATOR Model AS-SAS-14 AS-SAM-14 AS-SAL-14 Description SA - Std. pressure Drop SA - Medium Pressure drop SA - Low pressure drop SILENCER VELOCITY APPROX AS-SAS-14 <700 25% AS-SAM % AS-SAL-14 > % Product Description Sound attenuator are devices to come over noise problems generated by fans and impellers used in HVAC system noise produced by AHU and package units exhaust units with propellers are equally distributed approximately an all direction causing duct born noise breakout or flanking noise our silencers are reliable answer to these noise problems the selection of our silencer is mainly classified in three types depending upon the velocity of duct system I.e. for standard medium and low pressure drops all types are for reduction of noise by considering the important parameters such as insertion loss airflow regenerator noise and static pressure drop for forward or reverse flow the outer casing and baffles of silencer are fabricated from 20 gauge high quality mill galvanized steel to HVAC standard. The perforated baffles are filled with an odorless incombustible vermin proof and moisture proof inorganic sound absorbing material the baffles are aerodynamic in appearance designed to give 25% 33% and 50% free area for models standard pressure drop respectively. Silencers are equipped with G.I steel angles on the both sides of casing for easy and rigid installation and ducts. 110

111 SOUND ATTENUATOR SOUND ATTENUATOR Product Description Outer casing : lock formed 20 gauge galvanized steel sheet. All fixing by rivets for strength and rigidity. Baffles: they are made of 20 gauge perforated galvanized steel filled with absorbing materials that is resistant to vermin and moisture. Flanges: rolled steel angle flanges securely welded to the attenuator casing. SILENCER VELOCITY RARA RANGE FPM APPROX FREE AREA D S AS-SAS-14 <700 25% 8 3 AS-SAM % 8 4 AS-SAL-14 > %

112 SOUND ATTENUATOR SOUND ATTENUATOR 112

113 SOUND ATTENUATOR SOUND ATTENUATOR 112

114 SOUND ATTENUATOR SOUND ATTENUATOR 114

115 SOUND ATTENUATOR SOUND ATTENUATOR 115

116 SOUND ATTENUATOR SOUND ATTENUATOR 116

117 SOUND ATTENUATOR SOUND ATTENUATOR MODEL AS-SAS-14 AS-SAS-14 AS-SAS-14 AS-SAS-14 AS-SAS-14 AS-SAS-14 AS-SAS-14 AS-SAS-11 LENGTH mm TABLE 13 DYNAMIC INSERTION LOSS IN db Mid-frequency Octave Bands, Hz DYNAMIC INSERTION LOSS IN db AS-SAM-11 Mid-frequency Octave Bands, Hz MODEL LENGTH mm AS-SAM AS-SAM AS-SAM AS-SAM AS-SAM AS-SAM AS-SAM DYNAMIC INSERTION LOSS IN db AS-SAL-11 Mid-frequency Octave Bands, Hz MODEL LENGTH mm AS-SAL AS-SAL AS-SAL AS-SAL AS-SAL AS-SAL AS-SAL

118 SOUND ATTENUATOR SOUND ATTENUATOR PERFORMANCE DATA MODEL: AS-SAS-14 STANDARD PRESSURE DROP 118

119 SOUND ATTENUATOR SOUND ATTENUATOR PERFORMANCE DATA MODEL: AS-SAM-14 MEDIUM PRESSURE DROP 119

120 SOUND ATTENUATOR SOUND ATTENUATOR PERFORMANCE DATA MODEL: AS-SAL-14 LOW PRESSURE DROP 120

121 SOUND ATTENUATOR SOUND ATTENUATOR Model Description D (INCH) S (INCH) AS-SAS-14 SA - Std. pressure Drop 8 3 AS-SAM-14 SA - Medium Pressure drop 8 4 AS-SAL-14 SA - Low pressure drop

122 SOUND ATTENUATOR SOUND ATTENUATOR 122

123 LOCATION & CONTACTS LOCATION & CONTACT DETAILS P.O. BOX : Address : Factory 28/ block 2547/ road 1535 HIDD 115 Telephone : (00973) Fax : (00973) Type Of Firm Commercial Registration No. Membership No in Chamber of Commerce & Ind./MAIN BRANCH Field of Activity HIDD INDUSTERIAL AREA, KINGDOM OF BAHRAIN : W,L,L. : : : info@antalya-airtech.com : HVAC INDUSTRIES FACTORY AIR OUTLETS AIR DUCT ACCESSORIES Air Duct Fabrication. Service & Preventive Maintenance. SAUDI AGANT VISSION TRADING EST. EGYPT AGENTS VISSION TRADING EST. 123

124

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns.

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

SECTION AIR OUTLETS AND INLETS

SECTION AIR OUTLETS AND INLETS SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15820) - AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

AIR DUCT ACCESSORIES

AIR DUCT ACCESSORIES SECTION 233300 - PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS *s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT

More information

SECTION DUCTWORK

SECTION DUCTWORK PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating. SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser. SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

SECTION DUCTWORK

SECTION DUCTWORK SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).

More information

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today. FIRE & SMOKE DAMPERS Meeting tomorrow's requirements for fire and smoke protection today. LATEST TECHNOLOGY For more than 40 years Ruskin has led the HVAC industry in the manufacture of dampers and louvers.

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE

More information

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential

More information

Convectors Steam / Hot Water November, 2009

Convectors Steam / Hot Water November, 2009 Convectors Steam / Hot Water 13-111.3 November, 2009 TABLE OF CONTENTS I. Model Nomenclature...3 II. Design Benefits... 4-5 III. Typical Piping Arrangements....6 IV. Correction Factors A. Steam...7 B.

More information

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

Linear Floor Heaters

Linear Floor Heaters Linear Floor Heaters The Price Linear Floor Heater family provides ultimate flexibility in terms of style, performance, and ease of installation. Using room-side heat virtually eliminates the requirement

More information

Smoke extraction duct of sheet steel

Smoke extraction duct of sheet steel Smoke extraction duct of sheet steel The accessories that are available, as for example inspection openings, steel grilles, plenum boxes, ceiling diffusers, splitter attenuators, bends, tees and connecting

More information

Life Safety Dampers Selection and Application Manual

Life Safety Dampers Selection and Application Manual Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers August 2016 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED

More information

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION Experience the external venetian blind 80 S in action! www.warema.com/80s The new WAREMA external venetian blind 80 S PROVEN THINGS

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems 233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section

More information

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers elevent ceiling diffusers Technical Selection Swirl, Jet, Louvred and Curved ceiling diffusers Paltech elevent Ceiling Diffusers are protected by: Australian Patent 0179430 + other patents pending Australian

More information

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS Louvers & Dampers April 2008 P.O. Box 606 7435 Industrial Road Florence, Kentucky, 41042 Phone: (859) 647-2299 Fax: (859) 647-7810 Web Site: www.louvers-dampers.com Product Guide Specification SECTION

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

Contents INDEX. TDM Series Indirect Fired Heaters

Contents INDEX. TDM Series Indirect Fired Heaters Contents Typical Indoor Installations................... 000 Indoor Unit Dimensions (Vertical).............. 000 Indoor Unit Dimensions (Horizontal)............ 000 Outdoor Unit Dimensions.....................

More information

AIR HANDLER SPECIFICATION

AIR HANDLER SPECIFICATION AIR HANDLER SPECIFICATION Air Handlers AH-1 through 5 The following air handlers will be supplied: AH-1 FX15-4842 Series 5700 CFM AH-2 FX15-4236 Series 3990 CFM AH-3 FX15-3633 Series 2570 CFM AH-4 FX15-3330

More information

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional

More information

FIRE RATED PRODUCTS GENERAL PRODUCT OVERVIEW. Fire Rated Products

FIRE RATED PRODUCTS GENERAL PRODUCT OVERVIEW. Fire Rated Products IRE RATED PRODUCTS GENERAL PRODUCT OVERVIEW ire Rated Products Nailor offers a wide variety of fire rated products that are designed to provide the unobtrusive appearance required for architectural excellence

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

DACC Health Sciences Building Air Handler Assessment/Study

DACC Health Sciences Building Air Handler Assessment/Study DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.

More information

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2011 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,

More information

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2017 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,

More information

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

Residential Fans & Air Purifiers

Residential Fans & Air Purifiers Residential Fans & ir Purifiers ESSORIES Fan ccessories Mounting lamps for Rigid Duct M mounting clamps are designed for use with rigid duct. The foam neoprene layer creates an air tight and solid installation

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX010 November 2005 AXIAL POWER ROOF VENTILATORS Power Roof Ventilators Twin City Fan & Blower offers a wide variety of Power Roof Ventilators (PRVs). The PRVs have been

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015 Peter McDonnell, PE, LEED AP BD+C McClure Engineering UL DAMPER TEST STANDARDS UL 555 - FIRE DAMPERS UL555S SMOKE DAMPERS UL555C CEILING

More information

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products Fans s for f Life! CA-TD0708 The World s Leading Producer of Air Movement Products TD In-line Mixed Flow Duct Fans Soler & Palau (S&P) USA and Canada are the most recent additions to, and are wholly owned

More information

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening

More information

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork. SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Closed Circuit Cooling Towers

Closed Circuit Cooling Towers VFL - C 35 Closed Circuit Cooling Towers Product Detail VFL Closed Circuit Cooling Tower... C36 Benefits... C38 Construction Details... C40 Custom Features and Options... C41 Accessories... C43 Engineering

More information

SEPARATED COMBUSTION. General WARNING

SEPARATED COMBUSTION. General WARNING Form I-UD-V-SC (09-17) Obsoletes Form I-UD-V-SC (Version 05-17) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Combustion Air Inlet / Vent Terminal Options CC6 and

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

Part # Page Dampers Supported Directly From Structure 5. Dampers Supported From Ductwork Above 4

Part # Page Dampers Supported Directly From Structure 5. Dampers Supported From Ductwork Above 4 Part #453343 INSTALLATION INSTRUCTIONS DAMPERS AND LOUVERS CRD Series s These installation instructions apply to 3 hour rated ceiling radiation dampers mounted in a ceiling with supports from 1) a ceiling

More information

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is

More information

SECTION AIR DOORS

SECTION AIR DOORS SECTION 23 34 33 AIR DOORS Berner Series VSA air doors are designed for openings up to 12 ft for environmental separation and up to 10 ft for insect control. Berner Series VSB air doors are designed for

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 73 00_AIR HANDLING UNITS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular custom & semi-custom built indoor air handling

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV) Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

Displacement Ventilation

Displacement Ventilation Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser Therma-Fuser Systems Models: TLW-C VAV cooling only TLW-CW VAV cooling with constant volume warm up TLW-D Manually adjustable blades TLW-RAD

More information

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements. SECTION 15855 AIR HANDLING UNITS WITH COILS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Central Station Air Handling Units. B. Related Sections: 1.02 REFERENCES 1. Section 15010 - Basic Mechanical

More information

THREE-WAY HEAT SAVER/VENTILATOR

THREE-WAY HEAT SAVER/VENTILATOR BULLETIN 673 December 2009 THREE-WAY HEAT SAVER/VENTILATOR Modulated Damper Control System Operates in Supply, Exhaust, Heat Saver and Mixed-Air Modes Models RREH & RRES Three-Way Heat Saver/Ventilator

More information

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONSTANT VOLUME LINEAR CEILING DIFFUSER 12 CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL

More information

Smoke and Fire Curtains

Smoke and Fire Curtains Smoke and Fire Curtains NFPA UL Datasheet firecurtaintech.com SMOKE AND FIRE CURTAINS Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building

More information

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS Active chilled beam with cooling, heating and ventilation QUICK FACTS The ADRIATIC VF is a chilled beam with integrated recirculated air opening in the face plate. Air is discharged into the room along

More information

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage. LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal

More information

Therma-Fuser Square Thermally Powered VAV Diffuser

Therma-Fuser Square Thermally Powered VAV Diffuser ST Therma-Fuser Square Thermally Powered VAV Diffuser Therma-Fuser Systems Models: ST-HC Separate set points for VAV heating and VAV cooling ST-C One set point for VAV cooling only ST: Product Overview

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals

More information

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SO TOUGH, WE GUARANTEE IT. SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SSL SBS www.superiorrex.com SSL / SBS Series: BIG ON FEATURES; SMALL IN SIZE Contractors All SSL/SBS model blower-coil

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division AMERICAN COOLAIR CORPORATION Greenhouse Ventilation Systems Farm Products Division AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion

More information

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide 1.0 INTRODUCTION NTD-125-*, NTD-204-* & NTD-220-* Nuaire Installation Guide Nuaire Ductmaster Ducting (NTD) is a range of ing and ancillaries intended for installation in domestic properties. Nuaire Ducting

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR- HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR- HANDLING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

5 year fan housing and motor warranty

5 year fan housing and motor warranty MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box

More information

KSSS42QDW05, KSSS42QDX05

KSSS42QDW05, KSSS42QDX05 CABINET PARTS 42" BUILT IN REFRIGERATOR 4 97 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 Cabinet (Not A Serviceable Part) 3 2005004 Grommet, Tube Crossover 4 1112023 Roller, Front & Rear (4) 5 Support,

More information

Installation Instructions

Installation Instructions 53DS --- 900 --- --- --- 092 Duct---Free Systems Accessory Power Ventilation Kit for In --- Ceiling Cassette Fan Coil Units Size 018 --- 036 Installation Instructions NOTE: Read and become familiar with

More information