AIR-CONDITIONER SERVICE MANUAL SPLIT WALL TYPE RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR

Size: px
Start display at page:

Download "AIR-CONDITIONER SERVICE MANUAL SPLIT WALL TYPE RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR"

Transcription

1 FILE. SVM SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR 18 Class 24 Class Dec., 2001

2 CONTENT FILE. SVM SPECIFICATIONS 2. CONSTRUCTION VIEWS 2-1 Indoor Unit (RAS-24UKX, RAS-24UK-AR) 2-2 Indoor Unit (RAS-18UKX, RAS-18UK-AR) 2-3 Outdoor Unit (RAS-24UAX, RAS-24UA-AR) 2-4 Outdoor Unit (RAS-18UAX, RAS-18UA-AR) 3. WIRING DIAGRAM 3-1 RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR 3-2 RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR 4. SPECIFICATION OF ELECTRICAL PARTS 4-1 Indoor Unit 4-2 Outdoor Unit (RAS-24UAX, RAS-24UA-AR) 4-3 Outdoor Unit (RAS-18UAX, RAS-18UA-AR) 5. REFRIGERATION CYCLE DIAGRAM 5-1 RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR 5-2 RAS-18UKX / RAS-18UAX 5-3 RAS-18UK-AR / RAS-18UA-AR 6. CONTROL BLOCK DIAGRAM 7. OPERATION DESCRIPTION 7-1 Outline of Air Conditioner Control 7-2 Description of Operation Circuit 7-3 ECO. Mode 7-4 High-Temperature Limit Control 7-5 Low-Temperature Limit Control 7-6 Auto Restart Function 7-7 Filter Check Lamp 1

3 FILE. SVM INSTALLATION PROCEDURE 8-1 Safety Cautions 8-2 Installation Diagram of Indoor and Outdoor Units 8-3 Installation 8-4 Indoor Unit 8-5 Outdoor Unit 8-6 Others 9. TROUBLESHOOTING CHART 9-1 Troubleshooting Procedure 9-2 Basic Check Items 9-3 Primary Judgement 9-4 Self-Diagnosis by Remote Control (Check Code) 9-5 How to Diagnose Faulty Parts 9-6 Troubleshooting for Indoor Unit 9-7 Troubleshooting for Wiring (Interconnect Cable and Serial Signal Wire) 9-8 Troubleshooting for P.C. Board 9-9 Troubleshooting for Remote Control 10. PART REPLACEMENT 10-1 Indoor Unit 10-2 Outdoor Unit (RAS-24UAX, RAS-24UA-AR) 10-3 Outdoor Unit (RAS-18UAX, RAS-18UA-AR) 11. EXPLODED VIEWS AND PARTS LIST 11-1 Indoor Unit (1) 11-2 Indoor Unit (2) 11-3 Outdoor Unit (RAS-24UAX, RAS-24UA-AR) 11-4 Outdoor Unit (RAS-18UAX) 11-5 Outdoor Unit (RAS-18UA-AR) 2

4 1. SPECIFICATIONS FILE. SVM ITEM MODEL RAS-24UKX/24UAX RAS-24UK-AR/24UA-AR RAS-18UKX/18UAX RAS-18UK-AR/18UA-AR Cooling Cooling Cooling Cooling 220V 240V 220V 240V 220V 240V 220V 240V Capacity kw Phase 1Ø Power source V Hz 50 Power consumption W Power factor % Running 220V 240V 220V 240V 220V 240V 220V 240V current Indoor /Outdoor A 0.3/ / / / / / / /9.5 Starting current A Moisture removal lit/h Indoor (H/M/L) db 45/41/37 42/39/35 Noise Outdoor ( V) db Name of refrigerant R22 Refrigerant Rated amount kg Refrigerant control Capillary tube Gas side size mm Ø Ø 12.7 Connection type Flare connection Liquid side size mm Ø 6.35 Interconnection Connection type Flare connection pipe Maximum length 15* 1 m (One way) 25* 2 20* 2 Maximum height m 10 8 difference INDOOR UNIT RAS-24UKX RAS-24UK-AR RAS-18UKX RAS-18UK-AR Height mm 298 Dimensions Width mm 998 Depth mm 208 Net weight kg 12 Evaporator type Finned tube Indoor fan type Cross flow fan High fan m 3 /h Air volume Medium fan m 3 /h Low fan m 3 /h Fan motor output W 30 Air filter Honeycomb woven filter with PP frame OUTDOOR UNIT RAS-24UAX RAS-24UA-AR RAS-18UAX RAS-18UA-AR Height mm Dimensions Width mm Depth mm Net weight kg Condenser type Finned tube Outdoor fan type Propeller fan Airflow volume m 3 /h Fan motor output W Compressor Model PH280X3-4MS PH250X3-4LM Output W Safety device IOL Louver type Automatic louver Usable outdoor temperature range C 15 ~ ~ ~ ~ 52 3

5 Note : 1 Capacity is based on the following temperature conditions. FILE. SVM Condition JIS C Temperature Indoor unit inlet air temperature Outdoor unit inlet air temperature Cooling (DB) 27 C (WB) 19 C (DB) 35 C (WB) 24 C Note : 2 Charge refrigerant according to the table below. Refrigerant *1 No need to charge refrigerant *2 Need to charge refrigerant RAS-24UKX/24UAX RAS-24UK-AR/24UA-AR 15m or less Over 15m up to 25m (20g/m) RAS-18UKX/18UAX RAS-18UK-AR/18UA-AR 15m or less Over 15m up to 20m (20g/m) 4

6 2. CONSTRUCTION VIEWS FILE. SVM Indoor Unit (RAS-24UKX, RAS-24UK-AR) Back body Front panel Grille inlet or more Knock out system 50 Knock out system Outline of indoor unit 298 Minimum distance to ceiling Connecting pipe (0.39m) (Flare ø15.88) Drain hose (0.54m) Connecting pipe (0.49m) (Flare ø6.35) For stud bolt (ø6) For stud bolt (ø8 ø10) Installation Plate outline

7 2-2. Indoor Unit (RAS-18UKX, RAS-18UK-AR) FILE. SVM Back body Front panel Grille inlet or more Knock out system 50 Knock out system Outline of indoor unit 298 Minimum distance to ceiling Connecting pipe (0.39m) (Flare ø12.7) Drain hose (0.54m) Connecting pipe (0.49m) (Flare ø6.35) For stud bolt (ø6) For stud bolt (ø8 ø10) Installation Plate outline

8 2-3. Outdoor Unit (RAS-24UAX, RAS-24UA-AR) FILE. SVM Detail Drawing 600 ø12x18 hole A ø25 Drain outlet Service Port (pitch) A Handle 4-ø12x18 holes (for ø8 ø10 anchor bolt) Handle Mounting dimension of anchor bolt or more 600 or more Air inlet 100 or more Air outlet 600 or more 4-ø12x18 for ø8 ø10 anchor bolt 23 Electric Parts cover Liquid side (Flare ø6.35) Gas side (Flare ø15.88)

9 2-4. Outdoor Unit (RAS-18UAX, RAS-18UA-AR) FILE. SVM A Detail Drawing 600 R10 ø11x14 hole ø6 hole Handle ø420 A Fan guard ø25 Drain outlet 100 or more Installation dimension 600 Air inlet 600 or more Air inlet ø6 holes (for fixing outdoor unit) 6-ø11x14 holes (for ø8 ø10 anchor bolt) 100 or more Air outlet 600 or more 4xø11x14 for ø8-ø10 anchor bolt Service Port Electric Parts cover Liquid side (Flare ø6.35) Gas side (Flare ø12.7)

10 3. WIRING DIAGRAM FILE. SVM RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR BLK WHI RED BLK P04 CN30 CN31 CN COLOR IDENTIFICATION BRW : BROWN RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE GRN&YEL : GREEN & YELLOW GRN : GREEN R22 SG01 VARISTOR DSA T6.3A 250V F01 FUSE RY04 R09 R21 LOUVER MOTOR IC04 C15 L01 R01 C01 BLU PNK YEL ORN RED BRW CN 07 CN 10 DB01 MAIN P.C. BOARD (MCC-821) C02 FAN MOTOR DC MOTOR C06 T IC02 DC15V DC0V DC12V DC7V DC0V GRN&YEL CN IC IC01 CN CN BLU BLU BLU BLU BLU BLU BLU BLU BLU WHI BLK BLK CN INFRARED RAYS RECEIVE AND INDICATION PARTS THERMO SENSOR (TA) BLK BLK HEAT EXCHANGER SENSOR (TC) POWER TERMINAL BLOCK POWER SUPPLY V ~ 50Hz. L N BLK RED GRN&YEL INDOOR TERMINAL BLOCK OUTDOOR TERMINAL BLOCK FERRITE CORE INDOOR UNIT OUTDOOR UNIT GRN&YEL CHASSIS BLK BLK SPARK KILLER GRY BLK RED RED A1 52C A2 R U RED RED CAPACITOR WHI RED BLK S V CAPACITOR WHI PNK S R C BLK FAN MOTOR T W COMPRESSOR MAGNETIC SWITCH 9

11 3-2. RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR FILE. SVM BLK WHI RED CN30 CN31 CN COLOR IDENTIFICATION BRW : BROWN RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE GRN&YEL GREEN & YELLOW GRN : GREEN BLK R22 P04 SG01 VARISTOR DSA T6.3A 250V F01 FUSE RY04 R09 R21 LOUVER MOTOR IC04 C15 L01 R01 C01 BLU PNK YEL ORN RED BRW CN 07 CN 10 DB01 MAIN P.C. BOARD (MCC-821) + C02 FAN MOTOR DC MOTOR C06 T IC02 DC15V DC0V DC12V DC7V DC0V GRN&YEL CN IC IC01 CN CN BLU BLU BLU BLU BLU BLU BLU BLU BLU WHI BLK BLK CN INFRARED RAYS RECEIVE AND INDICATION PARTS THERMO SENSOR (TA) BLK BLK HEAT EXCHANGER SENSOR (TC) POWER SUPPLY V~ 50Hz POWER TERMINAL BLOCK L N BLK RED GRN&YEL RED INDOOR TERMINAL BLOCK OUTDOOR TERMINAL BLOCK BLK INDOOR UNIT OUTDOOR UNIT GRN&YEL CHASSIS BLK BLK SPARK KILLER RED BLK MAGNETIC RELAY A GRY B RED CAPACITOR RED CAPACITOR WHI PNK S R C BLK WHI RED BLK COMPRESSOR FAN MOTOR 10

12 FILE. SVM SPECIFICATION OF ELECTRICAL PARTS 4-1. Indoor Unit No. Parts name Type Specifications 1 Fan motor (for indoor) ICF Output (Rated) 30W, V 2 Thermo sensor (TA-sensor) 10k at 25 C 3 DC-DC transformer (T01) SWT-58A DC 390V, Secondary DC 15V, 12V, 7V 4 Microcomputer TMP87CM40AN 5 Heat exchanger sensor (TC-sensor) 10k at 25 C 6 Line filter (L01) SS11V-R mH, AC 0.7A 7 Diode (DB01) D3SBA60 4A, 600V 8 Capacitor (C02) KMH450VNSN120M25C 120µF, 450V 9 Fuse (F01) TSCR T6.3A, 250V 10 Relay (for outdoor fan motor, solenoid coil) (RY04) AJQ1341 Coil DC 12V, 33mA, Rated 1A, AC 250V 11 Power supply IC (IC01) MA8920 5A, 900V 12 Varistor (R21, R22) 15G561K 560V 13 Resistor (R01) RF-5TK4R7 4.7, 5W 14 Louver motor MP35EA12 Output (Rated) 2W,10poles, 1phase, DC 12V 4-2. Outdoor Unit (RAS-24UAX, RAS-24UA-AR) No. Parts name Type Specifications Output (Rated) 2200W, 2poles, 1phase, V, 50Hz 1 Compressor PA290X3F-4MS Winding resistance (Ω) Red-Black White-Black (at 20 C) Output (Rated) 65W, 6poles,1phase, V, 50Hz 2 Fan motor (for outdoor) MMF C Winding resistance (Ω) Red-Black White-Black (at 20 C) Running capacitor (for fan motor) Running capacitor (for compressor) 5 Bimetal thermostat 6 Magnetic switch SK45FMP SK42CMP45U1 CS-7C CLK-35J AC 450V, 3.5µF AC 420V, 45µF Open 130 ± 5 C, Close 70 ± 10 C V, 50Hz 11

13 4-3. Outdoor Unit (RAS-18UAX, RAS-18UA-AR) FILE. SVM No. Parts name Type Specifications Output (Rated) 1500W, 2poles, 1phase, V, 50Hz 1 Compressor PA225X3F-4L Winding resistance (Ω) Red-Black White-Black (at 20 C) Output (Rated) 65W, 6poles,1phase, V, 50Hz 2 Fan motor (for outdoor) HF A Winding resistance (Ω) Red-Black White-Black (at 20 C) Running capacitor (for fan motor) Running capacitor (for compressor) 5 Bimetal thermostat 6 Magnetic switch SK45FMP02U2 SK42CMP45U1 CS-7C VC20FA AC 450V, 2µF AC 420V, 45µF Open 130 ± 5 C, Close 70 ± 10 C V, 50Hz, 1P1a 12

14 5-1. RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR FILE. SVM REFRIGERATION CYCLE DIAGRAM Cooling Indoor unit Evaporator T 0.39m (Connecting pipe) Cross flow fan 0.49m (Connecting pipe) 6.35 O.D.:15.88mm P O.D.:6.35mm Packed valve ( ) Gas container connection (Reinstall etc.) Packed valve ( 6.35) Cooling Capillary tube 0.8x400S Cooling Compressor PH280X3-4MS Capillary tube 2.4x1400S Accumulator Condenser Liquid tank 25x140S Cooling Propeller fan Outdoor unit Mark ( Refrigerant R kg ) means check points of Gas Leak Cooling 50Hz Standard Pressure P (MPaG) Surface temp. of heat exchanger interchanging pipe T ( C) Fan Speed (indoor) Ambient temp. conditions DB/WB ( C) Indoor Outdoor Standard High 27/19 35/24 High temperature High 32/23 52/31* Low temperature Low 21/15 21/15 * SASO Standard s condition Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.) 13

15 FILE. SVM RAS-18UKX / RAS-18UAX Indoor unit Evaporator T 0.39m (Connecting pipe) 12.7 Cross flow fan 0.49m (Connecting pipe) 6.35 O.D.:12.7mm P O.D.:6.35mm Packed valve ( 12.7) Packed valve ( 6.35) Capillary tube 2.4x1000S Compressor PH250X3-4LM Condenser Muffler Propeller fan Refrigerant R kg Outdoor unit Mark ( ) means check points of Gas Leak Cooling 50Hz Standard Pressure P (MPaG) Surface temp. of heat exchanger interchanging pipe T ( C) Fan Speed (indoor) Ambient temp. conditions DB/WB ( C) Indoor Outdoor Standard High 27/19 35/24 High temperature High 32/23 43/26 Low temperature Low 21/15 21/15 Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.) 14

16 FILE. SVM RAS-18UK-AR / RAS-18UA-AR Indoor unit Evaporator T 0.39m (Connecting pipe) 12.7 Cross flow fan 0.49m (Connecting pipe) 6.35 O.D.:12.7mm P O.D.:6.35mm Packed valve ( 12.7) Packed valve ( 6.35) Capillary tube 2.0x1000S Compressor PH250X3-4LM Capillary tube 0.8x900S Condenser Propeller fan Refrigerant R kg Outdoor unit Mark ( ) means check points of Gas Leak Cooling 50Hz Standard Pressure P (MPaG) Surface temp. of heat exchanger interchanging pipe T ( C) Fan Speed (indoor) Ambient temp. conditions DB/WB ( C) Indoor Outdoor Standard High 27/19 35/24 High temperature High 32/23 52/31 Low temperature Low 21/15 21/15 Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.) 15

17 6. CONTROL BLOCK DIAGRAM FILE. SVM Heat Exchanger Sensor Indoor Unit Control Panel Functions Louver Control M.C.U. Operation Display Temperature Sensor Infrared Rays Signal Receiver Infrared Rays Initiallizing Circuit Clock Frequency Oscillator Circuit 3-minute Delay at Restart for Compressor Motor Revolution Control Processing (Temperature Processing) Timer Timer Display Filter Sign Display Fan Only Sign Display Indoor Fan Motor Remote Control Power Supply Circuit Outdoor unit ON/OFF Signal Louver ON/OFF Signal Noise Filter Relay Driver Louver Driver Louver Motor Relay RY04 From Outdoor Unit Outdoor Unit REMOTE CONTROL Remote Control Operation (START/STOP) Operation Mode Selection AUTO, COOL, DRY, FAN ONLY Temperature Setting Fan Speed Selection ON TIMER Setting OFF TIMER Setting Louver Auto Swing Louver Direction Setting ECO. Infrared Rays 16

18 7. OPERATION DESCRIPTION FILE. SVM Outline of Air Conditioner Control This is a fixed capacity type air conditioner, which uses a DC motor for an indoor fan. The DC motor drive circuit is mounted in the indoor unit. And electrical parts which operate the compressor and the outdoor fan motor, are mounted in the outdoor unit. The air conditioner is mainly controlled by the indoor unit controller. The controller operates the indoor fan motor based upon commands transmitted by the remote control and transfers the operation commands to the outdoor unit controller. The outdoor unit controller receives operation com mands from the indoor unit, and operates the outdoor fan motor and the compressor. (1) Role of indoor unit controller The indoor unit controller receives the operation commands from the remote control and executes them. Temperature measurement at the air inlet of the indoor heat exchanger by the indoor temperature sensor Temperature setting of the indoor heat exchanger by the heat exchanger sensor Louver motor control Indoor fan motor operation control LED display control Transferring of operation commands to the outdoor unit Receiving of information of the operation status and judging of the information or indication of error (2) Role of outdoor unit controller The outdoor unit controller receives the operation commands from the indoor controller and executes them. Compressor operation control Operation control of outdoor fan motor Operations according to the commands from the indoor unit Turning off the compressor and outdoor fan when the outdoor unit receives the shutdown command Louver control (1) Vertical air flow louver Position of veritcal air flow louver is automatically controlled according to the operation mode. Besides, position of vertical air flow louver can be arbitrarily set by pressing [SET] button. The louver position which is set by [SET] button is stored in the microcomputer, and the louver is automatically set at the stored position for the next operation. (2) Swing If [AUTO] button is pressed when the indoor unit is in operation, the vertical air flow louver starts swinging. When [AUTO] button is pressed again, it stops swinging Indoor fan control (DC Fan motor) (1) The indoor fan is operated by the stepless speed change DC motor. (2) For air flow level, speed of the indoor fan motor is controlled in five steps (LOW, MED and HIGH). If AUTO mode is selected, the fan motor speed is automatically controlled by the difference between the preset temperature and the room temperature. Table RAS-24UKX RAS-18UKX MODEL RAS-24UK-AR RAS-18UK-AR Motor speed Air flow level Motor speed Air flow level (rpm) (m 3 /h) (rpm) (m 3 /h) Cooling HIGH and MED Fan only LOW

19 7-2. Description of Operation Circuit (1) When turning on the breaker, the operation lamp blinks. This means that the power is on (or the power supply is cut off.) (2) When pressing [START / STOP] button on the remote control, receiving beep sounds from the indoor unit, and the next operation is performed together with opening the vertical air flow louver. (3) Once the operation mode is set, it is memorized in the microcomputer so that the previous operation can be effected thereafter simply by pressing [START / STOP] button Fan only operation ([MODE] button on the remote control is set to the fan only operation.) (1) When [FAN] button is set to AUTO, the indoor fan motor operates as shown in Fig When [FAN] button is set to LOW, MED or HIGH, the motor operates with a constant air flow. (Room temp.) (Preset temp.) Preset temp (Preset temp.: 24 C TE : *1: The values marked with *1 are calculated and controlled by the difference in motor speed between M+ and L. Fig Setting of air flow [FAN:AUTO] (2) ECO. operation cannot be set. M+ *1 *1 *1 L FILE. SVM Cooling operation ([MODE] button on the remote control is set to the cooling operation.) (1) The compressor, outdoor fan and operation display on the remote control are controlled as shown in Fig (Room temp.) (Preset temp.) Preset temp Fig ON ON OFF ON OFF ON (2) When [FAN] button is set to AUTO, the indoor fan motor operates as shown in Fig When [FAN] button is set to LOW, MED or HIGH, the motor operates with a constant air flow. (Room temp.) (Preset temp.) Preset temp TE : *1: The values marked with *1 are calculated and controlled by the difference in motor speed between M+ and L. Compressor Common relay M+ *1 *1 *1 L Outdoor fan OPERATION display Fig Setting of air flow [FAN:AUTO] 18

20 Dry operation ([MODE] button on the remote control is set to the dry operation.) (1) The compressor, outdoor fan and operation display on the remote control are controlled as shown in Fig (Room temp.) (Preset temp.) Preset temp Fig (2) The microprocessor turns the compressor on and off at the regular intervals (4 to 6 minutes). While the compressor is turning off, the indoor fan motor operates in the SUPER LOW position. The pattern of operation depending on the relation between room temperature and preset temperatures is shown in Fig Room temp. ON:6min. OFF:4min. ON:5min. OFF:5min. OFF Compressor ON Common relay ON:6min. OFF:4min. OFF:5min. ON:5min. OFF ON Outdoor fan display OPERATION FILE. SVM Automatic operation ([MODE] button on the remote control is set to the automatic operation.) (1) One of 2 operations (Cooling or Fan only) is selected according to difference between the preset temperature and the room temperature at which the automatic operation has started, as shown in Fig The Fan only operation continues until the room temperature reaches a level at which another mode is selected. (2) Temporary Auto When the TEMPORARY button on the indoor unit is pushed, the preset temperature is fixed at 24 C and the indoor unit is controlled as shown in Fig (Room temp.) (Preset temp.) C Cooling operation The louver moves to the position same as Hi Power operation Cooling operation Fan only operation RAS-24UKX, RAS-24UK-AR RAS-18UKX,RAS-18UK-AR Fig Preset temp.+1 Preset temp. Compressor Outdoor fan ON ON ON ON OFF OFF OFF Indoor fan L. *S.L. L. S.L. L. S.L. L. *Super Low Fig (3) [FAN] button on the remote control is set to AUTO only. (4) The ECO. operations can not be set. 19

21 7-3. ECO. Mode ([ECO.] button on the remote control is pressed.) When [ECO.] button is pressed while the indoor unit is in Cooling or Auto operation, ( ) mark is indicated on the display of the remote control and the unit operates quietly and mildly controlling air flow. (1) Cooling operation The preset temperature is changed automatically as shown in Fig (The value of the preset temperature on the remote control does not change.) Fan speed LOW FILE. SVM High-Temperature Limit Control The microprocessor detects the indoor heat exchanger temperature to prevent pressure of a refrigerating cycle from increasing excessively. The compressor and outdoor fan motor are controlled as shown in Fig Compressor OFF ON ON Outdoor fan OFF OFF ON Heat exchanger temp. ( C) ( C) Preset temp. is changed Preset temp. is changed Fig Low-Temperature Limit Control The microprocessor detects the indoor heat exchanger temperature to prevent the indoor heat exchanger from freezing. The compressor and outdoor fan motor are controlled as shown in Fig Preset temp. 0H 1H 2H TIME ECO. button is pressed Fig Heat exchanger temperature ( C) 6 2 Compressor ON Outdoor fan Less than 2 C continues for 5 minutes OFF Fig

22 7-6. Auto Restart Function The indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with the set operating conditions in the event of power supply being accidentally shut down. The operation will resume without warning three minutes after power is restored. This function is not set to work when shipped from the factory. Therefore it is necessary to set it to work How to set auto restart function FILE. SVM To set the auto restart function, proceed as follows: The power supply to the unit must be on; the function will not set if the power is off. Push the [TEMPORARY] button located in the center of the front panel continuously for three seconds. The unit receives the signal and beeps three times. The unit then restarts operating automatically in the event of power supply being accidentally shut down. When the unit is on standby (Not operating) Operation Push [TEMPORARY] button for more than three seconds. TEMPORARY button 0 3S The unit is on standby. Motions The unit starts to operate. The green lamp is on. After approx. three seconds, The unit beeps three times The lamp changes from and continues to operate. green to orange. If the unit is not required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it off. When the unit is in operation Operation Push [TEMPORARY] button for more than three seconds. Motions The unit is in operation. The green lamp is on. The unit stops operating. The green lamp is turned off. After approx. three seconds, The unit beeps three times. TEMPORARY button 0 3S If the unit is required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it on. While this function is being set, if the unit is in operation, the orange lamp is on. This function can not be set if the timer operation has been selected. When the unit is turned on by this function, the louver will not swing even though it was swinging automatically before shutting down. While the filter check lamp is on, the TEMPORARY button has the function of filter reset button. 21

23 How to cancel auto restart function To cancel automatic restart function, proceed as follows: Repeat the setting prodedure: the unit receives the signal and beeps three times. The unit will be required to be turned on with the remote control after the main power supply is turned off. FILE. SVM When the unit is on standby (Not operating) Operation Push [TEMPORARY] button for more than three seconds. TEMPORARY button 0 3S The unit is on standby. Motions The unit starts to operate. The orange lamp is on. After approx. three seconds, The unit beeps three times The lamp changes from and continues to operate. orange to green. If the unit is not required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it off. When the unit is in operation Operation Push [TEMPORARY] button for more than three seconds. Motions The unit is in operation. The orange lamp is on. The unit stops operating. The orange lamp is turned off. After approx. three seconds, The unit beeps three times. TEMPORARY button 0 3S If the unit is required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it on. While this function is being set, if the unit is in operation, the orange lamp is on Power Failure During Timer Operation When the unit is in Timer operation, if it is turned off because of power failure, the timer operation is cancelled. Therefore, set the timer operation again Filter Check Lamp When the elapsed time reaches 1000 hours, the filter check lamp indicates. After cleaning the filters, turn off the filter check lamp How To Turn Off Filter Check Lamp Push [TEMPORARY] button on the indoor unit. Note: If [TEMPORARY] button is pushed while the filter check lamp is not indicating, the indoor unit will start the Automatic Operation. 22

24 8. INSTALLATION PROCEDURE FILE. SVM Safety Cautions For general public use Power supply cord of Outdoor unit shall be more than 4 mm 2 (H07RN-F or 245 IEC66 : polychloroprene sheathed flexible cord) or 3.5 mm 2 (AWG-12). CAUTION DANGER To Disconnect the Appliance from the Main Power Supply. This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm. If this is not possible, a power supply plug with earth must be used. This plug must be easily accessible after installation. The plug must be disconnected from the power supply socket in order to disconnect the appliance completely from the mains. FOR USE BY QUALIFIED PERSONS ONLY. TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK. CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED BY WRONG WAY, ELECTRIC PARTS MAY BE DAMAGED. CHECK THE EARTH WIRE IS T BROKEN OR DISCONNECTED BEFORE INSTALLATION. DO T INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS. FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION. TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M.) FROM HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTORS, FURNACE, STOVES, ETC. WHEN MOVING THE AIR-CONDITIONER FOR INSTALLING IT IN ATHER PLACE AGAIN, BE VERY CAREFUL T TO GET THE SPECIFIED REFRIGERANT WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABRMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS. IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISOUS GAS. WARNING Never modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches. Do not install in a place which cannot bear the weight of the unit. Personal injury and property damage can result if the unit falls. Before doing the electrical work, attach an approved plug to the power supply cord. And make sure the equipment to be earthed. Appliance shall be installed in accordance with national wiring regulations. If you detect any damage, do not install the unit. Contact your Toshiba dealer immediately. CAUTION Exposure of unit to water or other moisture before installation may cause a short circuit. Do not store it in a wet basement or expose to rain or water. After unpacking the unit, examine it carefully for possible damage. Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and discharged air might disturb user s neighbors. To avoid personal injury, be careful when handling parts with sharp edges. Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation. 23

25 REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER FILE. SVM Please make sure certainly that the installation of this air conditioner will be reported to the local power supplier before installation. If you have any obscure problems (or if the power supplier does not accept the installation) of this appliance, service agency will take adequate countermeasures. Remark per EMC Directive 89/336/EEC To prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply. 1. The power connection for the air conditioner has to be done at the main power supply. This distribution has to be of an impedance. Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max.! 2. No other equipment has to be connected to this power line. 3. For detailed installation acceptance please contact with your power supplier, it restriction do apply for products like washing machines, air conditioners or electrical ovens. 4. For power details of the air conditioner, refer to the rating plate of the product. 24

26 8-2. Installation Diagram of Indoor and Outdoor Units For installation of the indoor unit, use the paper pattern on the back of the installation manual. FILE. SVM mm or more 65 mm or more Hook 1 Installation plate For the rear left and left piping Wall Hook 170 mm or more Insert the cushion between the indoor unit and wall, and lift indoor unit to make work easier. Air filter Shield pipe Do not allow the drain hose to get slack. Before install the wireless remote control With the remote control cover open, load the batteries supplied correctly, observing their polarity. 2 Wireless remote control Cover 3 Batteries 2 Wireless remote control 6 Pan head wood screw 4 Remote control holder Vinyl tape Apply after carrying out a drainage test. Cut the piping hole sloped slightly Make sure to run the drain hose sloped downward. The auxiliary piping can be connected the left, rear left, rear, right or bottom. Saddle Right 100 mm or more 600 mm or more 600 mm or more 100 mm or more Extension drain hose (Option:RB 821SW) Electric parts cover 600 mm or more 100 mm or more 600 mm or more 600 mm or more 100 mm or more Extension drain hose (Option:RB 821SW) Electric parts cover 600 mm or more Rear Rear left Bottom Insulate the refrigerant pipes separately with insulation, not together. Left 18 Class 24 Class 6 mm thick heat resisting polyethylene foam Loop the connective cable (about 100 mm in diameter and mm long). Loop the connective cable (about 100 mm in diameter and mm long). 25

27 8-3. Installation Optional installation parts FILE. SVM Part Code A B C Parts name Refrigerant piping Liquid side : 6.35 mm Gas side : mm (RAS-18UK) : mm (RAS-24UK) Pipe insulating material (polyethylene foam, 6 mm thick) Putty, PVC tapes Q'ty One each 1 One each <Fixing bolt arrangement of outdoor unit> RAS-18UAX / RAS-18UA-AR 600 mm Air inlet 120 mm RAS-24UAX / RAS-24UA-AR 600 mm 120 mm 340 mm 64 mm 325 mm 52 mm Air outlet Fig Air inlet Air outlet Fig Secure the outdoor unit with the fixing bolts and nuts if the unit is likely to be exposed to a strong wind. Use Ø8 mm or Ø10 mm anchor bolts and nuts. 26

28 FILE. SVM Accessory and installation parts Part No. Part name (Q'ty) Part No. Part name (Q'ty) Part No. Part name (Q'ty) Installation plate x 1 Battery x 2 Mounting screw 4 x 25 s x 8 2 Wireless remote control x 1 4 Remote control holder x 1 6 Pan head wood screw 3.1 x 16 s x 2 Others Name Owner's manual Installation manual This model is not equipped with an extention drain hose. Option : For the extention drain hose, use an optionally available RB-821SW or commercially available one. 27

29 8-4. Indoor Unit Installation place A place which provides the spaces around the indoor unit as shown in the above diagram. A place where there is no obstacle near the air inlet and outlet. A place which allows an easy installation of the piping to the outdoor unit. A place which allows the front panel to be opened. FILE. SVM Cutting a hole and mounting installation plate <Cutting a hole> When install the refrigerant pipes from the rear. Indoor unit CAUTION Direct sunlight to the indoor unit wireless receiver should be avoided. The microprocessor in the indoor unit should not be too close to r-f noise sources. (For details, see the owner's manual.) <Remote control> A place where there are no obstacles such as a curtain that may block the signal from the indoor unit. Do not install the remote control in a place exposed to direct sunlight or close to a heating source, such as a stove. Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference.) The location of the remote control should be determined as shown below. (Side view) 75 7 m (Top view) Indoor unit 5 m m * 7 m The center of the pipe hole is above the arrow. Fig After determining the pipe hole position on the mounting plate (100 mm A), drill the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side. TE: When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. <Mounting the installation plate> For installation of the indoor unit, use the paper pattern on the back of installation manual (English). Hook Pipe hole mm 65 Reception range Remote control Reception range Remote control * : Axial distance Fig Pipe hole Hook Indoor unit Thread Weight Fig Hook Pipe hole 8 Mounting screw 1 Installation plate 28

30 <When the installation plate is directly mounted on the wall> 1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. 2. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated above. 3. Install the installation plate horizontally in the wall. CAUTION When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage. Installation plate (Keep horizontal direction) Anchor bolt Electrical work FILE. SVM The supply voltage must be the same as the rated voltage of the air conditioner. 2. Prepare the power source for exclusive use with the air conditioner. TE: Wire type: More than 1.5 mm 2 (H07RN-F or 245 IEC66) or 1.3 mm 2 (AWG-16) CAUTION Use power specified above table. This appliance can be connected to the mains in the following way. Connection to fixed wiring : A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring. An approved circuit breaker or switches must used. 5 mm dia. hole Projection 15 mm or less TE: Perform wiring works so as to allow a generous wiring capacity. 5Mounting screw ø4 x 25 s Clip anchor (local parts) Fig CAUTION Failure to firmly install the unit may result in personal injury and property damage if the unit falls. In case of block, brick, concrete or similar type walls, make 5 mm dia. holes in the wall. Insert clip anchors for appropriate 5 mounting screws. TE: Secure four corners and lower parts of the installation plate with 6 to 8 mounting screws to install it. 29

31 Wiring connection Air Inlet grille Front panel CAUTION FILE. SVM Be sure to refer to the wiring system diagram labeled inside the front panel. Check local electrical cords and also any specific wiring instructions or limitation. 2 1 Connecting cable about 15 cm Terminal block Terminal cover Screw Cord clamp Screw Fig Earth line Connecting cable <How to connect the connecting cable> Wiring of the connecting cable can be carried out without removing of the front panel. 1. Remove the air inlet grille. Open the air inlet grille upward and pull it toward you. 2. Remove the terminal cover and cord clamp. 3. Insert the connecting cable (according to local cords) into pipe hole on the wall. 4. Take out the connecting cable through the cable slot on the rear panel so that it is exploded by about 15 cm long in the front side. 5. Insert the connecting cable fully into the terminal block and secure it by screw tightly. 6. Tightening torque : 1.2 N m (0.12 kgf m) 7. Secure the connecting cable with the cord clamp. 8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor unit. 40 mm 10 mm 10 mm Fig <Stripping length of connecting cable> Fig Fig mm Earth line TE: Use strand wire only. Wire type : More than 1.5 mm 2 (H07RN-F or 245 IEC66) or 1.3 mm 2 (AWG-16) TE: Connect the earth line to the metallic part (i mark) located at the side of 3P terminal. <How to install the air inlet grille on the indoor unit> When attaching the air inlet grille, the contrary of removed operation is performed. Fig

32 Piping and drain hose installation FILE. SVM To connect pipe after installation of unit (figure) <In case of rightward piping> After scribing slits of the body-right by a knife or a making-off pin, cut them by a pair of nippers or the like. 400 mm 300 mm (To the forefront of flare) Liquid side Gas side Outward form of indoor unit 43 mm R 30 mm (Use polisin (polyethylene core or the like for bending pipe.) Slit (Body-right) 80 Use the handle of screwdriver, etc. Fig Fig <In case of downward piping> After scribing slits of the body-right by a knife or a making-off pin, cut them by a pair of nippers or the like. TE: If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxillary pipes and wrap the facing tape around them. Slit (Body-right) CAUTION Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape. Fig <Left-hand connection with piping> Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use spring bender so as not to crush the pipe. Bend the connection pipe within a radius of 30 mm. Auxiliary pipes Installation plate Indoor unit Connecting cable Drain hose Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit. Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc. Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material.) When bending a pipe, carefully do it not to crush it. 31

33 Indoor unit fixing 1. Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. 2. Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate. 3. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked up on the installation plate. Hook 2 1 Hook here 1 Installation plate Fig Press (unhook) For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up at the specified parts. FILE. SVM Drainage 1. Run the drain hose sloping downwards. TE: Hole should be made at a slight downward slant on the outdoor side. Do not rise the drain hose. 50 mm or more Do not put the drain hose end into water. Fig Do not form the drain hose into a wavy shape. Do not put the drain hose end in the drainage ditch. 2. Put water in the drain pan and make sure that the water is drained out of doors. 3. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. Shield pipe Drain hose Inside the room Extension drain hose Push Push Fig CAUTION Fig Arrange the drain pipe for proper drainage from the unit. Improper drainage can result in dew-dropping. This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan. Therefore, do not store the power cord and other parts at a height above the drain guide. Wall Drain guide Space for pipes Fig

34 8-5. Outdoor Unit Installation place A place which provides the spaces around the outdoor unit as shown in the left diagram. A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. A place where the operation noise and discharged air do not disturb your neighbors. A place which is not exposed to a strong wind. A place free of a leakage of combustible gases. A place which does not block a passage. When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. An allowable length of the connecting pipe is up 15 m. (Refer to the table of TO CHARGE REFRIGERANT for detail.) An allowable height level is up to 8 m. (RAS-18UA) or 10 m. (RAS-24UA). A place where the drain water does not raise any problem. CAUTION 1. Install the outdoor unit without anything blocking the air discharging. 2. When the outdoor unit is installed in a place exposed always to a strong wind like a coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield. 3. Specially in windy area, install the unit to prevent the admission of wind. 4. Installation in the following places may result in trouble. Do not install the unit such places. A place full of machine oil. A saline-place such as coast. A place full of sulfide gas. A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment Refrigerant piping connection 1. Cut the pipe with a pipe cutter. Fig FILE. SVM Obliquity Roughness Warp 2. Insert a flare nut into the pipe, and flare the pipe. Projection margin in flaring : A (Unit : mm) Outer dia. of copper pipe Die Fig Pipe <Tightening connection> Align the centers of the connecting pipes and tighten the flare nut as far as possible with your fingers. Then tighten the nut with a spanner and torque wrench as shown in the figure. CAUTION Rigid 1.0 to to to 1.5 Imperial 1.5 to to to 2.5 Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. A A Strong wind Fig

35 Outer dia. of copper pipe 6.35 mm mm mm Tightening torque of flare pipe connections Externally threaded side Half union Use a wrench to secure. CAUTION Flare at indoor unit side Flare at outdoor unit side Fig Fig Flare nut (Unit : N m) Tightening torque 16 to 18 (1.6 to 1.8 kgf m) 50 to 62 (5.0 to 6.2 kgf m) 65 to 80 (6.5 to 8.0 kgf m) Internally threaded side Use a torque wrench to tighten. KEEP IMPORTANT 4 POINTS FOR PIPING WORK (1) Take away dust and moisture (Inside of the connecting pipes.) (2) Tight connection (between pipes and unit) (3) Evacuate the air in the connecting pipes using VACUUM PUMP. (4) Check gas leak (connected points) Evacuating FILE. SVM After the piping has been connected to the indoor unit, you can perform the air purge together at once. AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the manual of vacuum pump. <Use a vacuum pump> Be sure to use a vacuum pump with counter-flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops. 1. Connect the charge hose from the manifold valve to the service port of the gas side packed valve. 2. Connect the charge hose to the port of vacuum pump. 3. Open fully the low pressure side handle of the gauge manifold valve. 4. Operate the vacuum pump to start for evacuating. Perform evacuating for about 15 minutes if the piping length is 20 meters. (15 minutes for 20 meters) (assuming a pump capacity of 27 liters per minute.) Then confirm that the compound pressure gauge reading is 101 kpa ( 76 cmhg). 5. Close the low pressure side valve handle of gauge manifold. 6. Open fully the valve stem of the packed valves (both side of Gas and Liquid). 7. Remove the charging hose from the service port. 8. Securely tighten the caps on the packed valves. Compound pressure gauge -101kPa (-76cmHg) Handle Lo Charge hose Connecting pipe Pressure gauge Manifold valve Handle Hi (Keep full closed) Charge hose Vacuum pump adapter for counter-flow prevention Vacuum pump Packed valve at gas side Service port (Valve core (Setting pin)) Packed valve at liquid side Fig

36 FILE. SVM No need to charge refrigerant Need to charge refrigerant TO CHARGE REFRIGERANT RAS-18UKX / 18UAX RAS-18UK-AR / 18UA-AR 15 m or less Over 15 m up to 20 m (20g/m) RAS-24UKX / 24UAX RAS-24UK-AR / 24UA-AR 15 m or less Over 15 m up to 25 m (20g/m) <Packed valve handling precautions> Open the valve stem all the way out; but do not try to open it beyond the stopper. Securely tighten the valve stem cap with torque in the following table: Wiring connection 1. Remove the electric parts cover from the outdoor unit. 2. Connect the connecting cable to the terminal as identified with their respective matched numbers on the terminal block of indoor and outdoor unit. 3. When connecting the connecting cable to the outdoor unit terminal, make a loop as shown installation diagram of indoor and outdoor unit, to prevent water coming in the outdoor unit. 4. Insulate the unused cords (conductors) with water coming in the outdoor unit. Process them so that they do not touch any electrical or metal parts. Gas side Gas side (Ø15.88 mm) Gas side (Ø12.7 mm) Liquid side (Ø6.35 mm) Service port Tightening torque 65 to 80 N m (6.5 to 8.0 kgf m) 60 to 62 N m (6.0 to 6.2 kgf m) 16 to 18 N m (1.6 to 1.8 kgf m) 9 to 10 N m (0.9 to 1.0 kgf m) Hexagonel wrench : A (Unit : mm) Hexagonal wrench is required. A 5 mm 4 mm Same as Gas side <Stripping length of connection cable> Earth line Cord clamp 10 L N L N Terminal block Screw Power supply cord 10 Terminal block Earth line Screw Cord clamp Connecting cable A Power supply cord Earth line Connecting cable Fig Fig Model Power source Maximum running current Plug socket & fuse rating Power cord RAS-18UKX/ RAS-18UK-AR RAS-24UKX/ RAS-24UK-AR 50 Hz, V Single phase 16A 20A 18A 20A 4 mm 2 (H07RN-F or 245 IEC 66) or 3.5 mm 2 (AWG-12) CAUTION Wrong wiring connection may cause some electrical parts burn out. Be sure to comply with local codes on running the wire from outdoor unit to indoor unit (size of wire and wiring method etc.) Every wire must be connected firmly. TE: Connecting cable Wire type : More than 1.5 mm 2 (H07RN-F or 245 IEC66) or 1.3 mm 2 (AWG-16) 35

37 FILE. SVM Others Auto restart setting Gas leak test Electric parts cover D C This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure. Flare nut connections (Outdoor unit) Fig Flare nut connections (indoor unit) Valve stem cap connection Service cap B connection Valve stem cap connection Check the flare nut connections, valve stem cap connections and service port cap connections for gas leak with a leak detector or soap water. A Information The product was shipped with Auto Restart function in the off position. Turn it on as required. <How to set the auto restart> Press and hold down the TEMPORARY button for about 3 seconds. After 3 seconds, the electronic beeper makes three short beeps to tell you the Auto Restart has been selected. To cancel the Auto Restart, follow the steps described in the section Auto Restart Function of the Owner s Manual Test operation To switch the TEST RUN (COOL) mode, press TEMPORARY button for 10 sec. (The beeper will make a short beep.) TEMPORARY button Fig

38 9. TROUBLESHOOTING CHART FILE. SVM Troubleshooting Procedure: Follow the details of 9-2. Basic Check Items. If there is no trouble corresponding to 9-2, check whether or not there are faulty parts following 9-4. Self- Diagnosis by Remote Control Basic Check Items Power supply voltage The line voltage must be AC V. If it is not within this rage, the air conditioner may not operate normally Incorrect cable connection between indoor and outdoor units The indoor unit is connected to the outdoor unit with 4 cables. Check that the indoor and outdoor units have been properly connected with terminals assigned the same numbers. If the connectors are not properly connected, the outdoor unit will not operate normally, or OPERATION lamp and TIMER lamp will blink (5Hz) Program control The microcomputer operates as shown in Table to control the air conditioner. If there are any operational problems, check whether or not the problems correspond to Table If they correspond to the Table, they are not problems with the air conditioner, but they are indispensable operations to control and maintain the air conditioner properly. Table No. Operation of Air Conditioner Descriptions 1 When the main power supply is turned on, the OPERATION lamp on the indoor unit blinks. 2 The indoor fan motor speed does not change in the Dry operation. 3 The compressor is not turned off even though the room temperature is in the range that the compressor is turned off. 4 The compressor is not turned on and off even though the thermo control is operated in the Dry operation. 5 The compressor is not turned on even though the room temperature is in the range that the compressor is turned on. 6 The operation mode changes in the Automatic operation. 7 The Fan only operation continues in the Automatic operation. 8 The ECO. operation operation does not work. The OPERATION lamp blinks to indicate that power is turned on. If the [START/STOP] button is pressed, the lamp stops blinking. The lamp also blinks when the power supply is turned off. The indoor fan motor speed is automatically controlled in the Dry operation. The compressor has a function that it is not turned off for 3 minutes after it is turned on even though the room temperature is in the range that the compressor is turned off. In the Dry operation, the compressor is turned on and off automatically at the regular intervals, independent of the thermo control. The compressor is not turned on in the restart delay timer (3-minutes timer) operation. It is also not turned on after the power supply is turned on because of this timer operation. In Automatic operation, the room temperature is detacted every 15 minutes and the operation mode is changed according to difference between the room temperature and the preset temperature. When the room temperature is in the range (Preset temperature ± 1 C), the Fan only operation is selected. These operations do not work when the unit is in the Dry operation or Fan only operation. 37

39 9-3. Primary Judgement Role of indoor unit controller The indoor unit controller receives the operation commands from the remote control and executes them. Temperature measurement at the air outlet of the indoor heat exchanger by the indoor temperature sensor Temperature setting of the indoor heat exchanger by the heat exchanger sensor Louver motor control Indoor fan motor operation control LED display control Transferring of operation commands to the outdoor unit Failure diagnosis FILE. SVM The indoor unit diagnoses the operation condition and indicates the information of the self-diagnosis with the lamps on the display panel of the indoor unit. Table A B C D E F G H Lamps OPERATION lamp is blinking. (1Hz) OPERATION lamp is blinking. (5Hz) OPERATION lamp is blinking. (5Hz) OPERATION lamp is blinking. (5Hz) OPERATION lamp is blinking. (5Hz) OPERATION and TIMER lamps are blinking. (5Hz) OPERATION, TIMER and FAN ONLY lamps are blinking. OPERATION, TIMER and FAN ONLY lamps are blinking. Self-diagnosis Power failure (when the power supply is turning on) Thermo sensor (TA) short or break Heat exchanger sensor (TC) short or break Indoor fan motor lock or failure Indoor P.C. board failure Wrong wiring of connecting cable Gas shortage or other refrigerant cycle trouble Heat exchanger sensor open, break or short Overload relay or thermostat trouble of compressor Cycle failure The remote control does not work. The outdoor fan does not rotate. Table Diagnosis by detective operation Symptom Check Primary judgement Turn off the power supply once, then turn it on. Try to operate the remote control. The compressor operates. The compressor does not operate. The remote control still does not work. The remote control works. The indoor unit (and/or remote control) is/are defective. OK. The outdoor unit (Outdoor fan motor) is defective. An internal part of the compressor is defective. 38

40 9-4. Self-Diagnosis by Remote Control (Check Code) (1) If the lamps are indicated as shown B to H in Table 9-3-1, execute the self-diagnosis by the remote control How to use remote control in service mode FILE. SVM (2) When the remote control is set to the service mode, the indoor controller diagnoses the operation condition and indicate the information of the selfdiagnosis on the display of the remote control with the check codes. If a fault is detected, all lamps on the indoor unit will blink at 5Hz and it will beep for 10 seconds (Pi, Pi, Pi...). The timer lamp usually blinks (5Hz) during the self-diagnosis. MODE AUTO COOL DRY HEAT FAN ONLY TEMP. C Hr. ON OFF TIMER TEMP. FAN AUTO LOW MED. HIGH (1) Press [CHK] button with a tip of pencil to set the remote control to the service mode. 00 is indicated on the display of the remote control. The timer lamp on the indoor unit blinks continuously. (5 times per 1 sec.) AUTO MODE ACL CHK ECO. ON WC-E1BE START/STOP Alphanumeric characters are used for the check code. SET TIMER FAN OFF RSV CNL is 5. is 6. is A. is B. is C. is D. (2) Press [TEMP. 8] button. If there is no fault with a code, the indoor unit will beep once (Pi) and the display of the remote control will change as follows: ; 00 ; 01 ; 02 1d ; 1E 22 Check the unit with all 35 check codes (00 to 22). as shown in Table Press [TEMP. 9] button to change the check code backwards. If there is a fault, the indoor unit will beep for 10 seconds (Pi, Pi, Pi...). Note the check code on the display of the remote control. 2-digits alphanumeric will be indicated on the display. All lamps on the indoor unit will blink. (5 times per 1 sec.) (3) Press [START/STOP] button to release the service mode. The display of the remote control returns to as it was before service mode was engaged. 39

41 Block level Table Diagnosis function Check Check Unit Block Symptom code code status Indoor P.C. board The block is unidentifiable Cable connection Other parts (including compressor) The indoor thermo sensor (TA) is defective. Disconnection or short-circuit The indoor heat exchanger sensor (TC) is defective. Disconnection or short-circuit The indoor fan motor or its circuit is defective. The part other than the above parts on the indoor P.C. board is defective. EEPROM access error IOL operation The variation of TC, 5 minutes after starting the compressor, is 2K or less. The serial signals can not be transmitted and received between indoor and outdoor units. The crossover wire is connected wrongly. The serial signal transmitting circuit on the outdoor P.C. board is defective. The serial signal receiving circuit on the indoor P.C. board is defective. The operation command signals are not transmitted from the indoor unit to the outdoor unit. The reply serial signal has been transmitted when starting the unit, but stops being transmitted shortly after. 1. Compressor thermo operation Gas shortage Gas leak 2. Instantaneous power failure The discharge temperature is over 120 C. The IOL operation is defective. Operation continues. Operation continues. All off Operation continues. All off Operation continues. Operation continues. Operation continues. Operation continues. All off All off Condition The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is defected. And it returns to the normal condition when recovering from errors. The lamp on the indoor unit blinks when error is defected. And it returns to the normal condition when recovering from errors. The lamp on the indoor unit blinks when error is defected. The lamp on the indoor unit blinks when error is detected. FILE. SVM Judgement and action 1. Check the indoor thermo sensor (TA). 2. Check the indoor P.C. board. 1. Check the indoor heat exchanger sensor (TC). 2. Check the indoor P.C. board. 1. Check the connector circuit of the indoor fan motor (CN10). 2. Check the indoor fan motor. 3. Check the indoor P.C. board. 1. Check the indoor P.C. board. (EEPROM and peripheral circuits) Overload operation of refrigerating cycle 1. Check whether or not the TC sensor comes off. 2. Check whether or not it is possible to operate the compressor and the outdoor fan motor. 3. Check gas leak. 1. In the case of the outdoor unit not operating at all; Check the crossover cable and connect it properly. Check the outdoor P.C. board. 2. In the case of the outdoor unit operating normally; Check whether or not both of serial LED (Green) and serial LED (Orange) is blinking. If the serial LED (Green) is not blinking, check the outdoor P.C. board. If the serial LED (Orange) is not blinking, check the indoor P.C. board. If the operation command signals continue to be transmitted between 2 and 3 of the indoor terminal block, replace the outdoor P.C. board. 1. Repeatedly turn the indoor unit on and off with the interval of approx. 10 to 40 minutes. (The check code is not indicated during operation.) And supply gas. (Check gas leak.) 2. The indoor unit operates normally during the check. If the reply serial signal continues to be transmitted between 2 and 3 of the indoor terminal block, replace the outdoor P.C. board. If the signal stops between them, replace the indoor P.C. board. 1. Check the heat exchanger sensor (TD). 2. Gas purging When turning on the unit, the normal phase (RST) is detected but T-R waveform has not been detected for 120 seconds or more. 40

42 9-5. How to Diagnose Faulty Parts [09 Other cycle error] (1) FILE. SVM Operation Check item Conceivable principle cause Measure Does compressor operate? Item by symptoms Is compressor turned off shortly? Is TC sensor resistance value (10k at 25 C) normal? Does inner overload relay (in compressor) operate? Check charged amount of refrigerant. Check defective overload. Check compressor. Failure Replace compressor. Replace TC sensor. Is circuit wiring normal? Wiring check/modification Is TC sensor disconnected from the sensing element? Connect TC sensor properly. Indoor P.C. board is defective. Replace P.C. board. [09 Other cycle error] (2) Does indoor fan operate? Is connector connected properly? Are filters clogged? Clean filters. Connect connector properly. Replace condenser. Replace fan motor. Is condenser normal? Is indoor fan motor normal? Is TC sensor resistance value (10kΩ at 25 C) normal? Is charged amount of refrigerant normal? Is outside air low load? Anti-freezing operation Anti-freezing operation Replace TC sensor. Charge refrigerant. Indoor P.C. board is defective. Replacd P.C. board. 41

43 [0C Indoor TA sensor error] FILE. SVM Is CN04 (TA sensor connector) connected properly? Connect CN04 properly. Is TA sensor resistance value (10 kω at 25 C) normal? Replace TA sensor. Indoor P.C. board is defective. Replace P.C. board. [0d Indoor TC sensor error] Is CN05 (TC sensor connector) connected properly? Connect CN05 properly. Is TC sensor resistance value (10 kω at 25 C) normal? Replace TC sensor. Indoor P.C. board is defective. Replace P.C. board. 42

44 9-6. Troubleshooting for Indoor Unit Power can not be turned on. (The unit does not operate at all.) <Primary check> (1) Is the supply voltage normal? (2) Is the connection to the AC output OK? (3) Are the connection of the primary side and the secondary side of the power transformer inserted into the P.C. board? (4) Is the fuse (F01) blown? FILE. SVM Operation Check item Conceivable principle cause Measure Item by symptoms Turn off power supply once, and 5 second later, turn it on again. Is OPERATION lamp blinking? Is DC V suppalied to primary side of transfer switch? Is fuse (F01) of indoor control board blown? Is voltage (DC 12V or 5V) indicated on rear of indoor control board normal? Refer to <Primary check> or this praoblem is one step short of power P.C. board block. Is it possible to turn on power supply by pressing [START/STOP] button on remote control? Parts (R21, R22, SG01, C15, C01, DB01, C02, IC01 and T01) are defective. Does transmission mark on remote control flash normally, and is its signal transmitted properly? Does the fan motor connector between 1 and 2 short-circuit? Microcomputer is defective. Remote control is defective. Refer to 9-9 Troubleshooting for Remote Control. Replace main P.C. board. Unit operates normally. Are DC 15V, DC 12V and DC 7V supplied to secondary side of transfer switch? Turn off breaker once and turn it on againa after removing motor. Are DC 15V, DC 12V and DC 7V supplied to secondary side of transfer switch? Transfer switch, IC (IC01) for power supply or fan motor is defective. Replace motor. 43

45 Only indoor fan motor does not operate. FILE. SVM <Primary check> (1) Is it possible to detect the power supply voltage ( V) between 1 and 2 on the terminal block? (2) Does the indoor fan motor operate in cooling operation? Turn off power supply once, and turn it on again. Does compressor continue to operate? Is it possible to detect DC 1V or more between 5e and 3dof motor connector (CN10). Replace indoor fan motor. Start to operate indoor unit in cooling operation at airflow level LOW. Does indoor fan operate? Change airflow level to High. Is it possible to detect DC V between 1e and 3d of motor connector (CN10). (Motor connection condition) Is it possible to detect DC 15V between 4e and 3d of motor connector (CN10). Turn off indoor unit and remove connector from motor. Then press START/STOP button on remote control to stop blinking lamp on indoor unit. Start to operate the indoor unit. At this time, is it possible to detect DC 1V or more between 5e and 3d of motor connector (CN10)? Is it possible to detect DC 15V between 4e and 3d of motor connector (CN10). Replace main P.C. board. Is it possible to change airflow level to High? Is it possible to rotate crossflow fan by hand properly? Turn off indoor unit and remove connector from motor. Then start to operate indoor unit with remote control. Fan motor aoperates normally. Turn off indoor unit and rotate cross-flow fan by hand when the unit is on standby. At this time, is it possible to detect DC 1V or more between 5e and 3d of motor connector (CN10). Start to operate the indoor unit in except heating operation. At this time, is it possible to detect DC 1V or more between 5e and 3d of motor connector (CN10)? (Check this condition within 15 seconds after starting unit.) Replace bearing. 44

46 FILE. SVM Indoor fan motor automatically starts to rotate by turning on power supply. <Cause> The IC is built in the indoor fan motor. Therefore the P.C. board is also mounted to the inside of the motor. If the P.C. board is soldered imperfectly or the IC is defective, the fan motor may automatically rotate by turning on power supply. <Inspection procedure> (1) Remove the front panel. (Remove 4 screws.) (2) Remove the cover of the fan motor lead wires. (3) Check DC voltage with CN10 connector while the fan motor is rotating. TE: Do not disconnect the connector while the fan motor is rotating. Use a thin test rod. Indoor fan starts rotating when power supply is turned on. (Check output DC voltage of fan motor on P.C. board.) P.C. board CN10 Measure voltage between 2 (GND:BLACK) and 3 (V line:yellow) of motor connector (CN10) while indoor fan motor is rotating. Yellow Black 6 (Blue) 5 (Yellow) 4 (White) 3 (Black) 2 1 (Red) DC 1.0V or more Under DC 1.0V DC P.C. board is defective. Motor is defective. Replace P.C. board. Replace motor. 45

47 Compressor does not operate. <Primary check> (1) Is the preset temperature higher than the room temperature in cooling operation? (2) Is the crossover cable connected properly? <Inspection procedure> FILE. SVM Turn on power supply. Does OPERATION lamp blink? Refer to Power can not be turned on. Does miniature relay RY04 switch on and off due to temperature changes? Is resistance value of thermo sensor (TA) and heat exchanger sensor (TC) normal? Thermo sensor or heat exchanger sensor is defective. Is it possible to detect AC V between 2 and 3 on terminal block? Microcomputer is defective. Miniature relay RY04 is defective. Replace thermo sensor or heat exchanger sensor. Replace P.C. board. Are all of compressor cords normal? Rewire or replace defective cords. Is compressor motor winding normal? (Check winding resistor.) Compressor is defective. Replace compressor. Is capacitor for compressor normal? Capacitor is defective. Replace capacitor. Is overload relay normal? Overload relay is defective. Replace overload relay. Does compressor start? Compressor is defective. Replace compressor. Does compressor stop after a while? Is gas quantity normal? (Check gas pressure.) Gas shortage (Gas leak) Supply gas. Compressor is defective. Replace P.C. board. 46

48 <Inspection procedure> FILE. SVM Turn on power supply. Does OPERATION lamp blink? Refer to item Power can not be turned on. Is it possible to start unit by remote control? Refer to 9-9 Troubleshooting for Remote Control. Is it possible to detect DC 15 60V between 2 and 3 on terminal block? Is crossover cable normal? Is it possible to detect AC 12V on secondary side (CN06) of transfer? Check TA and TC sensors or refer to in Table Connect crossover cable properly. Replace transfer. Are all of compressor cords normal? Rewire or replace defective cords. Is compressor motor winding normal? (Check winding resistor.) Compressor is defective. Replace compressor. Is capacitor for compressor normal? Capacitor is defective. Replace capacitor. Is overload relay normal? Overload relay is defective. Replace overload relay. Does compressor start? Compressor is defective. Replace compressor. Does compressor stop after a while? Is gas quantity normal? (Check gas pressure.) Gas shortage (Gas leak) Supply gas. Compressor is defective. Replace P.C. board. 47

49 9-7. Troubleshooting for Wiring (Interconnect Cable and Serial Signal Wire) Outdoor unit does not operate. FILE. SVM <Inspection procedure> (1) Is the voltage between 2 and 3 of the indoor terminal block varied? (2) Are signals from the indoor unit to the outdoor unit transmitted correctly based upon the following diagram? TE: Measure the voltage for 2 minutes and 30 seconds after starting the unit. Prepare a diode for checking. Terminal block on indoor side Red 3 White 2 1 Terminal block Tester Fig Normal condition : After start operated about 2 minutes and 30 seconds. Voltage between 2 and 3 of the indoor s Terminal block should be equal AC 220 V. Abnormal condition : Don t found voltage AC 220V from terminal block (0V) Outdoor unit stops a while after starting the unit. <Confirmation procedure> Select one of 3 cases below and follow the procedure. (1) The outdoor unit stops between 10 and 20 minutes passed after starting and it takes 10 minutes or more to restart the unit. Gas has a low circulation. Measure gas pressure. Gas shortage Gas leak Pipe clogging Compressor is turned off and on automatically by thermo sensor or thermostat. (2) The outdoor unit stops once, it would not operate until the power is turned on again. Refer to Compressor does not operate. (3) The outdoor unit stops between 10 minutes to 1 hour after starting and a check code is indicated on the remote control. (Check code 03-1E : Refer to Table ) 48

50 9-8. Troubleshooting for P.C. Board How to check indoor P.C. board <Cautions for handling P.C. board> (1) When removing the front panel and the P.C. board, be sure to turn off the power supply. (2) When removing the P.C. board, hold the edge of the P.C. board and do not apply force to the parts. (3) When connecting or disconnecting the connectors on the P.C. board, hold the housing. Do not pull at lead wires. <Inspection procedure> FILE. SVM (1) If the P.C. board is detective, check for disconnection, burn or discoloration of the copper foil pattern of the P.C. board. (2) The P.C. board consists of the following 2 parts: a. Main P.C. board parts: Power relay, indoor fan motor drive circuit and control circuit, C.P.U. and peripheral circuits, buzzer drive circuit and buzzer. b. Infrared rays parts: Infrared rays receiving circuit Check the defects of the P.C. board with Table Turn off the power supply and remove the P.C. board assembly from electric parts base. Remove the connecting cables from the terminal block. 2 Remove the connector of the motor and turn on the power supply. If OPERATION lamp blinks (once per second), it is not neccessary to check steps (1 to 3) in the right next column. 3 Press [START/STOP] button once to start the unit. (Do not set the mode to Fan Only or On-Timer operation). 4 Shorten the line of the restart delay timer and start unit. Table Inspection procedure No. Procedure Check points Causes Check whenther or not the fuse (F01) is blown. Check power supply voltage; 1. Between TP2 and TP3 of CN12 ( V AC) 2. Between + and of CN02 (DC V) 3. Between C04 and output side of IC09 (DC15V) 4. Between 12V and GND 5. Between 5V and GND Check power supply voltage; 1. Between connector of Q33 and GND (for relay coil (DC12V)) 2. Between 1 and 2 of terminal block for connecting cable Check whether or not all lamps (OPERATION, TIMER, FAN ONLY, ECO. and AUTO) are indicated for 3 seconds and they return to normal 3 seconds later. Impluse voltage was applied or the indoor fan motor short-circuited. 1. The terminal block or the crossover cable is connected wrongly. 2. The capacitor (C01 and C15), line filter (L01), resistor (R01), or the diode (DB01) is defective. 3. IC01, IC02 and T1 are defective. 4. IC01, IC02, and T1 are defective. 5. IC01, IC02, IC07 and T01 are defective. 1. The wire of the relay coil (RY04) comes down or the relay drive (Q33) is defective. 2. CN27 or RY04 is connected wrongly. The lamps are defective or the housing assembly (CN13) is defective. 49

51 No. Procedure Check points Causes FILE. SVM Press [START/STOP] button once to start the unit. Shorten the time of the restart delay timer. Set the operation mode to COOL. Set the fan speed level to AUTO. Set the preset temperature much lower than the room temperature. (The unit (compressor) operates continuously in the above condition.) 6 Connect the motor connector to the motor and turn on the power supply. Start the unit in the following condition. Set the operation mode to FAN. Set the fan speed level to HIGH. (The unit (compressor) operates continuously in the above condition.) 1. Check whether or not the compressor operates. 2. Check whether or not the OPERA- TION lamp blinks. 1. Check it is impossible to detect the voltage (DC 15V) between 3 and 4 of the motor terminals. 2. The motor does not operate. (But it is possible to receive the signal from the remote control.) 3. The motor rotates but vibrates strongly. 1. The temperature of the indoor heat exchanger is extremely low. 2. The connection of the heat exchanger sensor is loose. (The connector is disconnected.) (CN01) 3. The heat exchanger sensor and the P.C. board are defective. (Refer to Table ) 4. The main P.C. board is defective. 1. The indoor fan motor is defective. (Protected operation of P.C. board) 2. The connection of the motor connector is loose. 3. The P.C. board is defective. Table Approximate resistance value of thermo sensor Temperature 0 C 10 C 20 C 25 C 30 C Resistance value (kω) How to reduce the operation time of the anti-restart timer (1) Set the operation mode, temperature, and air flow rate to be applied with the timer short mode. (2) Push the [CNL] button while keeping [CHK] button pushed. in this case, the check mode is released, and the timer short mode is waited. (The status is kept even if [CHK] and [CNL] buttons are released.) (3) Pushing [START/STOP] buttons sends operation code + timer short code. (4) The timer short mode is released by only a transmission. Therefore, repeat steps from (2) to perform the timer short mode again. TEMP. START/STOP AUTO SET FAN MODE ACL CHK ECO TIMER ON WC-E1BE OFF RSV CNL [CHK] botton [CNL] botton 50

52 FILE. SVM P.C. board layout Top View Bottom View 51

53 10-3. Outdoor Unit (RAS-18UAX, RAS-18UA-AR) FILE. SVM No. Part name Procedures Remarks 1 Common procedure 1) Stop the operation of the air conditioner and turn off its main power supply or remove the power supply wires. 2) Remove the electrical parts cover. (4 screws) 3) Remove the cord clamps. (4 screws) 4) Remove the connecting cables after removing 7 screws on the terminal block. 5) Remove the front cabinet. (8 screws) Pull the front lower portion toward you and pull out it upward to remove it. 6) Remove the back cabinet and side cabinet. (12 screws) Electrical parts cover Front cabinet Side cabinet 2 Running capacitor for compressor 1) Remove the capacitor band. (1 screw) 2) Disconnect the lead wires from the capacitor terminal. 3 Running capacitor for fan motor 1) Remove the capacitor band. (1 screw) 2) Disconnect the lead wires from the capacitor terminal. 4 Relay 1) Unlatch the relay and pull it upward. 2) Disconnect the lead wires from the relay terminal. 5 Spark killer 1) Remove the spark killer. (1 screw) 2) Disconnect the lead wire from the terminal block. Running capacitor for compressor Running capacitor for Fan motor P.C. board Relay Transformer 56

54 10. PART REPLACEMENT FILE. SVM Indoor Unit No. Part name Procedures Remarks 1 Front panel How to remove the front panel (2) 1) Stop the operation of the air conditioner and turn off its main power supply. 2) Pull the inlet grille toward you to open it and remove 4 screws fixing the front panel. 3) Remove upper 3 hooks of the front panel (2) from the back body. 4) Open the horizontal grille right below by 4-screws (3) hand. 5) Pull the lower side of the front panel toward you until it touches the horizontal grille to remove it. (2) How to mount the front panel 1) Mount the front panel with the inverse procedure of How to remove the front panel. 2) Push 3 places (right, left and center) of the air outlet. 3) Check the gap between the front panel and the back body. If you operate the air conditioner in cooling or dry operation without pushing the 3 places, the surface of the front panel may be covered with frost and have dewdrops. 2 Electrical part assembly 1) Remove the front panel with the procedure 1. 2) Remove the screw fixing the electrical part box. 3) Remove the drain guide. 4) Remove the connector (5P) for the fan motor and the connector (6P) for the louver motor from the microcomputer assembly. 5) Remove the screw for the earth, and pull the electrical part base toward you to remove it from the main unit. 6) Pull out the TC sensor from the sensor holder. (4) (3) Drain guide (5) Screw (2) Screw (6) TC sensor 5P 6P When assembling the electrical parts assembly, make the connecting cable U-shaped and put it in the drain pan. 53

55 FILE. SVM No. Part name Procedures Remarks 3 Horizontal grille 1) Remove center 2 shafts of the horizontal grille from the back body. 2) Remove left shaft of the horizontal grille from the back body. 3) Remove the horizontal grille from the back body. (1) Center shafts (2) Left shafts 4 Heat exchanger 1) Remove the front panel, electrical parts assembly and the horizontal grille with procedure 2 and 3. 2) Remove the screw on the rear side of the main unit to remove the pipe holder. 3) Remove 2 screws fixing the heat exchanger and the bearing base. 4) Remove 2 screws fixing the heat exchanger fixtures (upper and lower) and the back body then pull out the upper side of the heat exchanger slowly. (2) Screw Bearing base Pipe holder (3) 2 screws (4) 2 screws 5 Cross flow fan 1) Remove the front panel, electrical parts assembly, horizontal grille and the heat exchanger with procedure 4. 2) Loosen the set screw of the cross flow fan. 3) Remove 2 screws fixing the bearing base and the back body. 4) Pull the cross flow fan toward you. (3) Screws (2) Set screw When assembling the cross flow fan, fix it with the set screw at the position where the gap between the back body and the right surface of the cross flow fan is 4 mm. 6 Bearing base 1) Remove the front panel, electrical parts assembly, horizontal grille, heat exchanger and the cross flow fan with procedure 5. 2) Remove the bearing from the bearing base. If the housing protrudes from the base bearing, put the housing in position and assemble the bearing to the bearing base. 7 Fan motor 1) Remove the front panel, electrical parts assembly, horizontal grille, and the heat exchanger with procedure 4. 2) Loosen the set screw of the cross flow fan. 3) Remove 2 screws of the motor fixture. 4) Remove the lower side of the body (R) and move it right to remove it. 5) Remove the motor from the motor fixture. Bearing base Bearing (4) (3) 2 screws (4) BODY (R) Motor fixture 54

56 10-2. Outdoor Unit (RAS-24UAX, RAS-24UA-AR) FILE. SVM No. Part name Procedures Remarks 1 Common procedure 1) Stop the operation of the air conditioner and turn off its main power supply or remove the power supply wires. 2) Remove the electrical parts cover. (4 screws 4 x 10) 3) Remove the side cabinet (front). (2 screws 4 x 10) 4) Disconnect the connecting cables after removing 7 screws on the terminal block. 5) Remove the side cabinet (back). (10 screws 4 x 10) Side cabinet (Front) Top cabinet Electrical parts cover Side cabinet (Back) 2 Running capacitor for compressor 1) Remove the capacitor band. (1 screw) 2) Disconnect the lead wires from the capacitor terminal. 3 Running capacitor for fan motor 1) Remove the capacitor band. (1 screw) 2) Disconnect the lead wires from the capacitor terminal. 4 Magnet switch 1) Remove the relay. (2 screws) 2) Disconnect the lead wire from the terminal. 5 Spark killer 1) Remove the spark killer. (1 screw) 2) Disconnect the lead wire from the terminal block. Spark killer Running capacitor for compressor Running capacitor for Fan motor Megnet switch 55

57 10-3. Outdoor Unit (RAS-18UAX, RAS-18UA-AR) FILE. SVM No. Part name Procedures Remarks 1 Common procedure 1) Stop the operation of the air conditioner and turn off its main power supply or remove the power supply wires. 2) Remove the electrical parts cover. (4 screws) 3) Remove the cord clamps. (4 screws) 4) Remove the connecting cables after removing 7 screws on the terminal block. 5) Remove the front cabinet. (8 screws) Pull the front lower portion toward you and pull out it upward to remove it. 6) Remove the back cabinet and side cabinet. (12 screws) Electrical parts cover Front cabinet Side cabinet 2 Running capacitor for compressor 1) Remove the capacitor band. (1 screw) 2) Disconnect the lead wires from the capacitor terminal. 3 Running capacitor for fan motor 1) Remove the capacitor band. (1 screw) 2) Disconnect the lead wires from the capacitor terminal. 4 Relay 1) Unlatch the relay and pull it upward. 2) Disconnect the lead wires from the relay terminal. 5 Spark killer 1) Remove the spark killer. (1 screw) 2) Disconnect the lead wire from the terminal block. Running capacitor for compressor Running capacitor for Fan motor P.C. board Relay Transformer 56

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE -(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-04004-3 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKHP-E3 / RAS-13UAH-E3 RAS-10UKHP-E3 / RAS-10UAH-E3 RAS-07UKHP-E3 / RAS-07UAH-E3 RAS-13UKP-E3 / RAS-13UA-E3 RAS-10UKP-E3 / RAS-10UA-E3

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-05009-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E4 / RAS-24UAH-E4 RAS-18UKHP-E4 / RAS-18UAH-E4 RAS-24UKP-E4 / RAS-24UA-E4 RAS-18UKP-E4 / RAS-18UA-E4 RAS-24UKP-AR4 / RAS-24UA-AR4

More information

RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2

RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2 FILE. SVM-03009 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2 18 Class (Heat

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-05010-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE 42CJR024-723 / 38CJR024-723 42CJR018-723 / 38CJR018-723 42TAR024X-723 / 38TAR024X-723 42TAR018-723 / 38TAR018-723 42HNR024-713 / 38HNR024-713

More information

AIR-CONDITIONER SERVICE MANUAL UNDER CEILING / CONSOLE TYPE

AIR-CONDITIONER SERVICE MANUAL UNDER CEILING / CONSOLE TYPE FILE. SVM-02009 SERVICE MANUAL AIR-CONDITIONER UNDER CEILING / CONSOLE TYPE RAS-18UFHP-ES / RAS-18UAH-ES RAS-18UFP-ES / RAS-18UA-ES RAS-24UFHP-ES / RAS-24UAH-ES RAS-24UFP-ES / RAS-24UA-ES 18 Class 24 Class

More information

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T FILE. SVM-06009 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T June, 2006 CONTENTS FILE. SVM-06009 1. SPECIFICATIONS 2.

More information

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E R32 INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) ENGLISH Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E Outdoor unit RAS-10PAVPG-E RAS-13PAVPG-E RAS-16PAVPG-E 1121451198 EN CONTENTS PRES FOR

More information

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-07SKSX-1 / RAS-07S2AX-1 RAS-09SKSX-1 / RAS-09SASX-1

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-07SKSX-1 / RAS-07S2AX-1 RAS-09SKSX-1 / RAS-09SASX-1 FILE. SVM-08028 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-07SKSX-1 / RAS-07S2AX-1 RAS-09SKSX-1 / RAS-09SASX-1 April, 2008 CONTENTS FILE. SVM-08028 1. SPECIFICATIONS 2. CONSTRUCTION VIEWS 2-1 Indoor

More information

CONTENTS 1. SPECIFICATIONS CONSTRUCTION VIEWS Indoor Unit Outdoor Unit... 7

CONTENTS 1. SPECIFICATIONS CONSTRUCTION VIEWS Indoor Unit Outdoor Unit... 7 6 5 0 1 * ).1 - ) '$' 5-4 8 1 + - ) 7 ) ) 1 4 +, 1 6 1 5 2 1 6 9 ) 6 4 ) 5 5 04 ) - 5 5 ) 0 4 ) 5 5 40 ): 5 5 ) 0 2 4 1 6 -, 1 ) 2 ) L ' ' $ CONTENTS 1. SPECIFICATIONS... 4 2. CONSTRUCTION VIEWS... 6 2-1.

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-06005 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-18NKHD-E5 / RAS-18NAH-E RAS-18NKD-E5 / RAS-18NA-E RAS-24NKD-E5 / RAS-24NA-E RAS-18NKDX5 / RAS-18N2AX RAS-24NKDX5 / RAS-24N2AX 18 Class

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-06004 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-18NKHP-E / RAS-18NAH-E RAS-18NKP-E / RAS-18NA-E RAS-24NKP-E / RAS-24NA-E RAS-B18NKPX / RAS-18N2AX RAS-24NKPX / RAS-24N2AX 18 Class 24

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

RAS-24SKP-ES2 / RAS-24SA-ES2 RAS-24SKHP-ES2 / RAS-24S2AH-ES2

RAS-24SKP-ES2 / RAS-24SA-ES2 RAS-24SKHP-ES2 / RAS-24S2AH-ES2 FILE. SVM-10049 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24SKP-ES2 / RAS-24SA-ES2 RAS-24SKHP-ES2 / RAS-24S2AH-ES2 April, 2010 CONTENTS FILE. SVM-10049 1. SPECIFICATIONS 2. CONSTRUCTION VIEWS

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

INSTALLATION MANUAL ENGLISH FRANÇAIS AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-30, 32SK Series. Outdoor unit RAS-30, 32S Series

INSTALLATION MANUAL ENGLISH FRANÇAIS AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-30, 32SK Series. Outdoor unit RAS-30, 32S Series INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) ENGLISH FRANÇAIS Indoor unit RAS-30, 32SK Series Outdoor unit RAS-30, 32S Series 1110651147 Toshiba 1110651147 (COVER_F) EN CONTENTS FR SOMMAIRE PRES FOR

More information

INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-05, 07, 10, 13, 16BKV-E. Outdoor unit RAS-05, 07, 10, 13, 16BAV-E

INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-05, 07, 10, 13, 16BKV-E. Outdoor unit RAS-05, 07, 10, 13, 16BAV-E INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) ENGLISH Indoor unit RAS-05, 07, 10, 13, 16BKV-E Outdoor unit RAS-05, 07, 10, 13, 16BAV-E 1118350197 EN CONTENTS PRES FOR SAFETY...1 ACCESSORY PARTS...2

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

Choosing the installation site. Installation. 07 Choosing the installation site

Choosing the installation site. Installation. 07 Choosing the installation site Installation Installation warnings: 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state, and national electrical codes and by qualified,

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the

More information

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump COMFORT...BUILT TO LAST 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump INSTALLATION MANUAL INDOOR UNIT: 1PAMSH09-SZW-14.5 1PAMSH09-SZW-15 1PAMSH12-SZW-15 1PAMSH18-SZW-15

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL (Inverter Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

RAS-07EKH/RAS-07EAH RAS-09EKH/RAS-09EAH

RAS-07EKH/RAS-07EAH RAS-09EKH/RAS-09EAH FILE NO. A10-9508 SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-07EKH/RAS-07EAH RAS-09EKH/RAS-09EAH PRINTED IN JAPAN, Dec., 1995 S CONTENTS 1. SPECIFICATIONS... 3 ~ 5 2. CONSTRUCTION VIEWS... 6 ~

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL MSZ-D30/36NA MSY-D30/36NA JG79A061H01 Phillips screwdriver Level Scale Utility knife or scissors 3 in. (75 mm) hole saw Torque wrench Wrench (or

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL Model names are indicated in 1-3. JG79A145H05 Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench Wrench (or

More information

38VYX025-R, 38VYX035-R

38VYX025-R, 38VYX035-R 38VYX025-R, 38VYX035-R GB OUTDOOR INSTALLATION MANUAL NL BUITENMODULE MONTAGE-INSTRUCTIES I ESTERNA MANUALE D INSTALLAZIONE GR ÏÄÇÃÉÅÓ ÅÃÊÁÔÁÓÔÁÓÇÓ X F EXTERIEURE MANUAL D INSTALLATION P EXTERIOR MANUAL

More information

RAV-SM566KRT-E RAV-SM806KRT-E

RAV-SM566KRT-E RAV-SM806KRT-E AIR CONDITIONER (SPLIT TYPE) Installation Manual Unit Model name: High Wall Type RAV-SM566KRT-E RAV-SM806KRT-E For commercial use Installation Manual English xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx

More information

SPLIT-TYPE ROOM AIR CONDITIONER

SPLIT-TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT-TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing the

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL JG79A191H07 MSZ-GE06/09/12/15/18NA MSY-GE09/12/15/18NA When installing multi units, refer to the installation manual of the multi unit for outdoor

More information

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1 Order No: MAC0512115C1 CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU Air Conditioner CONTENTS Page Page 1 Safety Precautions 3 2 Specification 5 2.1. CS-E18EKU CU-E18EKU 5 2.2. CS-E21EKU CU-E21EKU 7 3 Location

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL MSZ-D30/36NA MSY-D30/36NA JG79A061H09 Phillips screwdriver Level Scale Utility knife or scissors 3 in. (75 mm) hole saw Torque wrench Wrench (or

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS

More information

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL Duct Type Series MH FECA INSTALLATION MANUAL Duct Type Series MH FECA ENGLISH FRANÇAIS ESPAÑOL Free Joint Multi Air Conditioner (Cooling and Heating) E S F DB98-960A() Safety Precautions The following safety precautions must be

More information

38VYX110/38VYX130 I S O INSTALLATION MANUAL

38VYX110/38VYX130 I S O INSTALLATION MANUAL LLOYD'S REGISTER QUALITY ASSURANCE 38VYX110/38VYX130 I S O 9 00 1 INSTALLATION MANUAL Heat pump split system outdoor units For operation and maintenance instructions of this unit as well as installation

More information

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents. All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567 2020323B2335 (June

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B P/N: 52FS2B54070-R CONTENTS PRECAUTIONS Important Safety Information Hints For Economical Operation Standard Safety Instructions

More information

Installation Manual. Indoor Unit MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL

Installation Manual. Indoor Unit MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL AIR CONDITIONER (MULTI TYPE) Indoor Unit Model name: High Wall Type MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL 1 English Manuel d installation 32 Français

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL MSZ-FH09/12/15NA JG79A805H01 When installing multi units, refer to the installation manual of the multi unit for outdoor unit installation. Phillips

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating) INSTALLATION MANUAL MANUAL DE LA INSTALACIÓN MANUEL D INSTALLATION MANUALE INSTALLAZIONE MANUAL DE INSTALAÇÃO INSTALLATIONSHANDBUCH INSTALLATION MANUAL Indoor unit AS09HPAN AS12HPAN Outdoor unit AS09HPAX

More information

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed) OPERA TION & I NSTALLAT I O N FDT11 FDT15 FDT18 MANUAL DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed) Read this operating & installation instruction carefully and keep it for future reference DUCTED

More information

Installation manual for room air conditioner

Installation manual for room air conditioner Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O

More information

AIR CONDITIONER (MULTI-SPLIT TYPE)

AIR CONDITIONER (MULTI-SPLIT TYPE) OUTDOOR UNIT INSTALLATION MANUAL AIR CONDITIONER (MULTI-SPLIT TYPE) For general public use Outdoor Unit RAS-M14GAV-E RAS-M18UAV-E RAS-M14GACV-E RAS-M18GACV-E ENGLISH EN CONTENTS 1 PRECAUTIONS FOR SAFETY...

More information

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL SG79Y427H02 INSTALLATION MANUAL SPLIT-TYPE AIR CONDITIONERS Models MSZ-GA22/GA25/GA35VA Series MUZ-GA25/GA35VA [FLARE CONNECTION TYPE] HFC utilized R410A When installing an MXZ series outdoor unit, refer

More information

Air Conditioner. user installation & manual manual. imagine the possibilities

Air Conditioner. user installation & manual manual. imagine the possibilities ARFSSSBWK Series ARFSSSCUR AJ JNADCH Series Air Conditioner user installation & manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung

More information

FLOOR TYPE AIR CONDITIONERS

FLOOR TYPE AIR CONDITIONERS FLOOR TYPE AIR CONDITIONERS MFZ-KJ25VE MFZ-KJ35VE MFZ-KJ50VE MFZ-KJ60VE Installation Manual For INSTALLER When installing multi units, refer to the installation manual of the multi unit for outdoor unit

More information

FILE NO. SVM SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-10UKV-E / RAS-10UAV-E

FILE NO. SVM SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-10UKV-E / RAS-10UAV-E SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-10UKV-E / RAS-10UAV-E Apr., 2002 CONTENTS 1. SPECIFICATIONS 1-1. Specifications 2. REFRIGERANT R-410A 2-1. Safety During Installation/Servicing 2-2. Refrigerant

More information

R410A SPLIT SERIES DC INVERTER

R410A SPLIT SERIES DC INVERTER R410A SPLIT SERIES DC INVERTER Models ECO906SD ECO908SD ECO1206SD ECO1208SD ECO1806SD Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2D52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

HEAT PUMP INSTALLATION MANUAL

HEAT PUMP INSTALLATION MANUAL DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL Models: TERRA09HP230V1A TERRA12HP230V1A TERRA18HP230V1B TERRA24HP230V1B Thank you for choosing a Gree Terra Ductless Heat Pump for your customer. Please

More information

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English EH99862001-2 AIR CONDITIONER (SPLIT TYPE) Installation manual Branch kit 1:3 Model name: RBC-TRP100E Installation manual Air conditioner (Split type) 1 English Please read this Installation Manual carefully

More information

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 SPLIT-TYPE AIR CONDITIONER CONTENTS INSTALLATION MANUAL 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 Model MXZ-A26/32WV HFC utilized R410A 2. INSTALLATION DIAGRAM & ACCESSORIES... 2 3. SELECTING

More information

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Split-type Air-Conditioner MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Deutsch Français Nederlands Español Italiano

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual Presents SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual 9k,12k 18k 24k, 30k, 36k ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 Phone: 800.325.5479

More information

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11 MWM36Y3J MRM36Y3J 11 Content Operation Notices Precautions...1 Parts name...2 Screen Operation Guide Buttons on remote controller...3 Introduction for icons on display screen...3 Introduction for buttons

More information

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E. For OUTDOOR USE only.

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E. For OUTDOOR USE only. AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit For OUTDOOR USE only Model name: RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E *NOTE: Descriptions about operations for the E unit in this manual are not applicable

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS - Wall-mount indoor unit - OPERATING LIMITS Cooling Maximum conditions Heating Maximum conditions Outdoor temperature : 122 F (50 C) D.B. Outdoor temperature : 75 F (24 C) D.B.

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 Service Manual Room Air Conditioner Split Wall-Mounted Type Applies to: HSG-09CRN1 HSG-12CRN1 HSG-18CRN1 HSG-24CRN1 HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 NOTE: Please read this first before servicing

More information

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units Installation and Operation Manual CMA12SB-0 Series Horizontal/Side Discharge Condensing Units 517.787.2100 www.marsdelivers.com www.heatcontroller.com Heat Controller CONTENTS PAGE 1. PRES... 1 2. INSTALLATION

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

YC ON-OFF SERIES. Service Manual

YC ON-OFF SERIES. Service Manual YC ON-OFF SERIES Service Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Model Lists... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 11 4. Refrigerant

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR

More information

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION English SG79Y367H0 SG79Y367H3 INSTALLATION MANUAL SPLIT-TYPE AIR CONDITIONERS Models MS-GA50/60VB MSH-GA50VB Series MSH-CA50VB [FLARE CONNECTION TYPE] HFC utilized R40A When installing an MXZ series outdoor

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2C52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79B528H01 Model names are indicated in 1-3. Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench

More information

Installation Manual. Indoor Unit

Installation Manual. Indoor Unit SUPER MODULAR MULTI SYSTEM AIR CONDITIONER Indoor Unit Model name: For commercial use Pour usage commercial Nur für gewerbliche Nutzung Per uso commerciale Para uso comercial Para uso comercial Voor commercieel

More information

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKV-E2 / RAS-13UAV-E2

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKV-E2 / RAS-13UAV-E2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKV-E2 / RAS-13UAV-E2 Jun., 2003 CONTENTS 1. SPECIFICATIONS 1-1 Specifications 1-2 Operation Characteristic Curve 1-2 Capacity Variation Ratio According

More information

TABLE OF CONTENTS. Air Conditioner CS-E24GKES CU-E24GKE CS-E28GKE CU-E28GKE

TABLE OF CONTENTS. Air Conditioner CS-E24GKES CU-E24GKE CS-E28GKE CU-E28GKE Order No. MAC0701008C2 CS-E24GKES CU-E24GKE CS-E28GKE CU-E28GKE Air Conditioner TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 2 2 Specifications -----------------------------------------------------

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79B530H01 Model names are indicated in 1-3. Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench

More information

TABLE OF CONTENTS. Air Conditioner CS-NE7GKE CU-NE7GKE CS-NE9GKE CU-NE9GKE CS-NE12GKE CU-NE12GKE

TABLE OF CONTENTS. Air Conditioner CS-NE7GKE CU-NE7GKE CS-NE9GKE CU-NE9GKE CS-NE12GKE CU-NE12GKE Order No. MAC0705021C2 Air Conditioner CS-NE7GKE CU-NE7GKE CS-NE9GKE CU-NE9GKE CS-NE12GKE CU-NE12GKE TABLE OF CONTENTS PAGE 1 Safety Precaution ------------------------------------------------ 2 2 Specifications

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2E52VAD MXZ-3E54VAD MXZ-4E71VAD Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the

More information

Service Manual. Air Conditional

Service Manual. Air Conditional Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30CM -3 - CONTENTS SPECIFICATION...

More information

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1 Wall Mounted AIR CONDITIONER Installation Manual KS Series KS09 KS12 KS18 KS24 KS28 J3387_Kaden_Installer_Manual_050917.indd 1 5/09/2017 9:07 AM J3387_Kaden_Installer_Manual_050917.indd 2 5/09/2017 9:07

More information

RAS-13UKV-E RAS-13UAV-E

RAS-13UKV-E RAS-13UAV-E FILE NO. A0-00 SPLIT TYPE RAS-3UKV-E RAS-3UAV-E PRINTED IN JAPAN, Mar.,00 ToMo CONTENTS. SPECIFICATIONS... 3. REFRIGERANT R40A... 5 3. CONSTRUCTION VIEWS... 3 4. WIRING DIAGRAM... 5 5. SPECIFICATIONS OF

More information

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79Y335H01 Model names are indicated in 1-3. When installing multi units, refer to the installation manual of the multi unit for outdoor

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE Order No. PHAAM1103074C8 Indoor Unit CS-MRE7MKE CS-MRE9MKE CS-MRE12MKE Air Conditioner Outdoor Unit CU-2RE15MBE CU-2RE18MBE TABLE OF CONTENTS PAGE 1 Safety Precautions-----------------------------------------------

More information

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S Split Air Conditioner Model: WMI09MH16S WMI12MH16S WMI18MH16S Thank you for choosing our product. For proper operation, please read and keep this manual carefully. Content Operation Notices Precautions...1

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Please read this user manual first! Dear Customer, Thank you for preferring a Beko product.

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE RAS-13NKV-E / RAS-13NAV-E RAS-13NKV-A / RAS-13NAV-A RAS-16NKV-E / RAS-16NAV-E RAS-16NKV-A / RAS-16NAV-A

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE RAS-13NKV-E / RAS-13NAV-E RAS-13NKV-A / RAS-13NAV-A RAS-16NKV-E / RAS-16NAV-E RAS-16NKV-A / RAS-16NAV-A -1 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13NKV-E / RAS-13NAV-E RAS-13NKV-A / RAS-13NAV-A RAS-16NKV-E / RAS-16NAV-E RAS-16NKV-A / RAS-16NAV-A June, 2005 CONTENTS 1. SPECIFICATIONS 1-1 Specifications

More information