OIL-FIRED INSTANT 25 CPR, SP AND SP/A MODELS

Size: px
Start display at page:

Download "OIL-FIRED INSTANT 25 CPR, SP AND SP/A MODELS"

Transcription

1 Energy-saving technology Wall-mounted fan-assisted boilers OIL-FIRED INSAN 25 CR, S AND S/A MODELS USERS' INSRUCIONS LB762o - 08/07/1999

2 Energy-saving technology CONENS: - echnical data pag. 3 - General points pag 3 - Hydraulic diagrams pag. 4 - Notes on boiler installation pag. 6 - Overall dimensions pag. 6 - Connection set pag. 6 - Connection to system and main pag. 6 - Installing the boiler pag. 7 - Electrical connection pag. 7 - Available head with standard pump pag. 7 - Checking rotation of the circulation pump pag. 8 - Control panel pag. 9 - Operation of the boiler pag. 9 - Fuel supply pag Conversion of the pumps for single pipe systems pag Boiler supplied by lift pump pag Room ventilation pag Snorkel connection for combustion air pag Connection of flue duct pag Regulating combustion pag Standard jets fitted to installed burners pag Operating cycle of the installed burner pag INSAN 25 electrical diagram and installed burners pag Access to the boiler pag Dismantling the burner pag Replacing the jet and position of the electrodes pag Maintaining and cleaning the boiler pag Exploded drawing of the heating control panel pag Exploded drawing of the INSAN 25 heater pag Exploded drawing of the boiler jacket pag Explosion of the burner pag. 29

3 Energy-saving technology INSAN 1F GASOLIO 25 Oil-fired instant 25 CR + S + S/ACE type approval number Rated heat output min/max kcal/h min/max kw 17,4 25 Rated heat output min/max kcal/h min/max kw 20 27,6 Max operating temperature C 90 Max circuit pressure bar 4 Max hot water pressure (*) bar 6 Boiler capacity l 30 Quantity of hot water produced ( t= 35 C) l/min 10,2 at maximum input ( t= 25 C) l/min 14,3 Expansion tank l 10 Expansion tank precharge pressure bar 1 Electrical power supply ~V/Hz 230 / 50 Max rated power W 240 Gross weight kg 112 Diameter of air/flue ducts mm (*) = refers to model CR CR = heating and instantaneous production of domestic hot water S = heating only S/A = heating and connection to external hot water storage cylinder GENERAL OINS he high-efficiency INSAN CR boiler is designed to meet all heating and domestic hot water heating needs. he unit is of unparalleled reliability and ensures safe operation, thanks to the extremely robust construction and use of fan-assisted burner technology.articular attention has been paid to safety and quiet operation since this unit is designed mainly for domestic use.he creation of an adequate draft through the combustion chamber and flue circuit by the burner fan prior to ignition, as well as the room-sealed construction of the combustion chamber, guarantees the maximum possible level of safety.domestic hot water is produced using a highly efficient braze-welded plate exchanger made from self-cleaning stainless steel: the self-cleaning action is obtained by virtue of the special shape of the plates. he INSAN S model (S = no domestic hot water) is designed for domestic heating only, while the S/A model provides central heating and also has an outlet for connection to a hot water storage cylinder. INSAN units can be connected to a room thermostat enabling automatic temperature control. Warning: his boiler is designed to raise water to a temperature below boiling point at atmospheric pressure; it must be connected to a heating system and/or domestic hot water production and distribution unit, within the limits of its output and performance specifications. Every other use of this equipment should be regarded as improper and therefore dangerous. he boiler must be installed by qualified professional fitters, in accordance with current standards and regulations on safety. Faulty installation can cause damage to persons and property for which the manufacturer cannot be held responsible. pag. 3

4 OIL-FIRED INSAN 1F 25 Energy-saving technology HYDRAULIC DIAGRAMS INSAN 25 CR A 2B ,, boiler unit2 2 - burner 2a - fuel solenoid-valve 2b - fuel pump 3 - fuel filter 4 - expansion tank 5 - circulation pump 6 - boiler drain valve 7 - automatic air vent valve 8 - sensor housing 9 - hot water exchanger 10 - three-way flow assembly 11 - enable microswitch 12 - return assembly 13 - filler valve 14 - system safety valve 13 heating system flow hot water outlet cold water inlet heating system return fuel inlet fuel return INSAN 25 S A 2B 1 - boiler unit 2 - burner 2a - fuel solenoid-valve 2b - fuel pump 3 - fuel filter 4 - expansion tank 5 - circulation pump 6 - boiler drain valve,, automatic air vent valve 8 - sensor housing 9 - safety valve 10 - filler valve heating system flow system return water supply fuel inlet fuel return pag. 4

5 Energy-saving technology OIL-FIRED INSAN 1F INSAN 25 S/A boiler unit 2 - burner 2a - fuel solenoid-valve 2b - fuel pump 3 - fuel filter 4 - expansion tank 5 - circulation pump 6 - boiler drain valve 7 - sensor housing 8 - automatic air vent valve 9 - safety valve 10 - hot water cylinder 11 - three-way solenoid valve 12 - boiler thermostat 13 - fuel shut-off valve 14 - fuel shut-off valve 15 - filler valve 6 1,, A 4 2B HO WAER OULE Heating system flow B A Fuel inlet Fuel return Boiler water inlet Heating system return M 11 COLD WAER INLE o be carried out by the installer pag. 5

6 OIL-FIRED INSAN 1F 25 Energy-saving technology NOES ON BOILER INSALLAION he boiler must be installed by professionally qualified fitters, observing UNI and CEI standards and following safety regulation procedures. Incorrect installation can cause damage to both persons and property, for which the manufacturer will not be held responsible. OVERALL DIMENSIONS Figure A details the dimensions of the boiler. Warning: a 400 mm. free space above the boiler should be allowed for maintenance. CONNECION SE (supplied with unit) A wall-mounted galvanised steel backplate-template is provided to facilitate water connections and boiler positioning. flue outlet air inlet 600 (boiler width) ø 100 ø , , (boiler height) = = a b c d e f fig. A a - Heating system flow G 3/4 b - Hot domestic water G 1/2 c - Fuel inlet ø 17 d - Fuel return ø 17 e - Cold domestic water G 1/2 f - Heating system return G 3/4 fig. B N.B. It is advisable to install a drain outlet (with special 1/2" funnel) for boiler safety valves. Connection kit for INSAN 25 CR Connection kit for INSAN 25 S and S/A a b c d e f a c d e f Fig. C connections referred to figure B. pag. 6

7 Energy-saving technology OIL-FIRED INSAN 1F INSALLING HE BOILER A A X X - position the bracket (supplied) in the selected location; - using a spirit level, check that the bracket is horizontal; - drill the backplate fixture holes at location A: use plugs of suitable size and strength when fixing the bracket to the wall; - position pipes and following the indications on the lower bracket; the template can be removed by breaking along the perforated line (axis x-x). Fig. 1 Fig. 2 lift from here After mounting the template to the wall (fig. 1), hook boiler unit to backplate as shown in figure 2. Before connecting up the boiler, clean carefully, removing any encrustations and eliminating any foreign bodies which might detract from the efficiency of the unit. he unit should be installed in an accessible position for ease of cleaning. Suitable stopcocks should be fitted on all inlet and outlet pipes. Once the boiler has been mounted on the wall, the water connections can be completed (fig. C page 6). Unit safety valves must be connected up to a suitable outlet. MANUAL FILLER he INSAN 25 boiler unit is equipped with a manual valve for filling the heating system. he INSAN 25 S and S/A boiler (no domestic hot water) is provided with an attachment (on the backplate) including a heating system filler valve for connection to the water supply,. he filling operation should be done slowly so that the air can escape through the series-mounted automatic air-vent valve, as well as through any other valves installed in the heating system. he filling pressure for the boiler when cold is indicated on the boiler pressure gauge on the boiler control panel and must be between 1 and 1.2 bar. his should be checked periodically. If the boiler pressure falls below the minimum value described above, the user must restore pressure by opening the valve. ELECRICAL CONNECION he boiler is connected up using the plug (ref. A) located at the bottom of the unit. IMORAN: he boiler unit must be connected to the electrical power supply following the existing legal safety standards. he supply cable must have a minimum section of 1mm2 for lengths of up to 2 metres, or 1.5mm2 for greater lengths. A Electrical connection must include a section switch with a gap between contacts of at least 3 mm. so as to guarantee unit isolation from the power supply. Lock out Return pag. 7 (room thermostat) 230V 50 Hz Output Negative Earth ositive S3 2 1 N L1 Boiler connection plug S3 2 1 N L1

8 OIL-FIRED INSAN 1F 25 Energy-saving technology AVAILABLE HEAD WIH SANDARD UM 6 5 Head (m c.a.) 4 3 V1 V2 V ,0 0,5 1,0 1,5 2,0 2,5 Flow rate (m 3 /h) CHECKING ROAION OF HE CIRCULAION UM IMORAN: Check before proceeding that neither the pump nor the water are boiling and take necessary precautions to prevent possibility of injury from scalding or damage in the event of leaks. he pump is interlocked to the minimum temperature thermostat and will be shut off temporarily whenever the boiler water temperature falls below a minimum. Bleeding the circulation pump: - loosen the plug A and bleed out any air; - expect water to drip from the cap opening after air bleeding and take precautions to prevent any ensuing damage to ot pump components; - retighten the plug A. Freeing a seized pump: - remove plug A - try to rotate the impeller using a screwdriver inserted into the slot on the shaft, taking care not to damage the slot; - replace plug A, checking that there is no leak. SARING U HE CIRCULAION UM Before turning the appliance and pump on, make certain that the system is filled with water and has been properly bled. Circulation pumps may be noisy when starting up for the first time; this can be caused by a small quantity of air trapped in the circuit. Follow bleeding procedure as above. N.B. After a long period of inactivity, for example the summer period, the pump may seize. o free it, follow the procedure described above. pag. 8

9 Energy-saving technology OIL-FIRED INSAN 1F 25 CONROL ANEL 10 9.A.S. MINIMA 8 1 INSAN 0 I RESEING HE SAFEY HERMOSA 3 Unscrew and remove hood. LEGEND 1 emperature and pressure gauge 2 ush button for resetting the flame failure device. In the event of the burner being stopped by the flame detector safety device, the push button will light up; to restart the burner, depress the button. 3 Safety thermostat with manual reset; this cuts in to stop the burner when the water temperature in the boiler exceeds the set value. hermostat is reset manually by depressing the button located beneath the protective cover. 4 Circulation pump indicator. 5 Boiler on/off switch. 6 Summer-winter selector (CR and S/A models only). 7 Boiler thermostat: regulates the temperature of the water in the boiler with the burner in operation or on standby. 8 Fuse 9 Minimum-temperature thermostat: maintains boiler water temperature above set value. When the boiler temperature falls below minimum unit circulation pumps are switched off. 10 Domestic water thermostat (models CR and S/A): controls the boiler temperature when domestic water is in use. his is diffe rent to the temperature of the boiler during heating or standby phases. OERAION OF HE BOILER Use of 0-I switch (all models) and - selector (CR ed S/A) In the 0 position the switch isolates the boiler from the power supply; in position I the control panel is connected to the power supply. In the position the - selector ensures that the boiler produces only domestic hot water; in the position the boiler can deliver central heating and domestic hot water, with hot water taking priority. 0 I CR AND S/A MODELS WINER OERAION (production of domestic hot water and central heating water, hot water taking priority). Set the selector to the symbol (winter operation). In the CR model, the boiler switches on and starts up in central heating mode, raising and maintaining the water temperature in the boiler to the temperature set with the boiler thermostat; the pump starts up whenever the temperature reaches the value set on the minimum temperature thermostat. When the room thermostat contacts open, the heating cycle is completed. If hot water is drawn off, the boiler will automatically switch to hot water production when there is a demand for hot water (e.g. if a tap is turned on); the temperature of the hot water in the boiler is controlled by the domestic hot water thermostat. pag. 9

10 OIL-FIRED INSAN 1F 25 Energy-saving technology In the S/A model the boiler will start up in hot water mode to meet the temperature set with the cylinder thermostat; the boiler temperature is regulated by the hot water thermostat. When the set temperature has been reached, the three-way valve will switch to heating and the boiler temperature is regulated by the boiler thermostat. When the room thermostat contacts open, the heating cycle is completed. SIMULANEOUS DEMAND FOR HEAING AND HO WAER (CR MODELS) If there is a demand for hot water while the heating is on, the boiler will automatically switch to hot water production (hot water has priority over heating). WARNING: in order to ensure the availability of hot water at any time, as well as safe and trouble-free operation of the equipment, it is advisable not to switch off the unit completely using the 0-I switch (for example at night) but to adjust the room thermostat (or timer/thermostat) or position the season selector to (Summer). SUMMER OERAION (DOMESIC HO WAER RODUCION ONLY) Selector set to In the CR model, the boiler switches on and starts up by raising and maintaining the water temperature set with the boiler thermostat. It will relight automatically if the water temperature falls below the temperature set with the thermostat. In the S/A model, the boiler starts up in response to the temperature set with the boiler thermostat. LEASE NOE: in order to ensure the availability of hot water at all times, a well as safe and troublefree operation of the boiler, it is advisable not to switch off the unit completely using the 0-I switch. S MODELS WINER OERAION (heating only) Switch on the boiler (0-I switch in the I position). he boiler is switched on and, after performing a self-test routine, immediately starts to raise the water temperature to the value set on the boiler thermostat, guaranteeing that the temperature remains at the set value. he circulation pump starts up whenever the minimum set value is reached. Once the room thermostat contacts open, the heating cycle is completed. Use the boiler thermostat to raise or lower the water temperature. pag. 10

11 Energy-saving technology OIL-FIRED INSAN 1F 25 FUEL ALIMENAZIONE SULY DEL COMBUSIBILE H pipe length in metres metres copper pipe bore = 8mm gravity feed, supplied from the 0,5 38 top of the tank , , H H suction feed H pipe length in metres metres copper pipe ø int. 8 mm ø int.10 mm 0, , , , OIL UM DANFOSS BF 11 R3 SUNEC AS 47 S R V Inlet 2 - ressure gauge and breather port 3 - Vacuum gauge port 4 - ressure set screw 5 - Outlet (pressure flow to nozzle) 6 - Return flow SUNEC CONVERSION OF HE UM FOR SINGLE IE SYSEMS DANFOSS UM o convert the DANFOSS pump: 1) Remove the pump cover and the internal filter 2) Remove the screw located inside the return port as shown in the figure on the left. 3) Replace the pump filter and cover. 4) Blank off the return port with a metal plug and seal. SUNEC UM o convert the SUNEC pump: 1) Remove the socket screw A located inside the return port. 2) Blank off the return port with a metal plug and seal. ertire la pompa SUNEC: Warning: unlike double pipe systems, air is not automatically bled out in a single pipe system. It is therefore essential to bleed the line on first operation as even a minimal infiltration of air in the fuel line will cause the burner to shut down. pag. 11

12 OIL-FIRED INSAN 1F 25 Energy-saving technology WARNING: o guarantee smooth and efficient operation of the appliance, the difference in height between fuel tank and burner should be no more than 3.5 metres. For greater differences it is essential to install a fuel lift pump (see diagram). Also, the condition and cleanliness of the fuel line filter should also be checked periodically, and the filter replaced where necessary. BURNER SULIED BY LIF UM Hydraulic diagram When it is impossible for the pump to draw fuel from the tank atmospherically, due to the boiler being sited on an upper storey, an auxiliary electric pump will need to be installed. he figure shows a possible arrangement, with two separate appliances supplied from a single tank. he electrical connection is made such that the auxiliary pump will switch off when all burners are shut down. N.B. Maximum fuel supply circuit pressure MUS NO exceed 2 bar; the preferred operating pressure is 0.5 bar. H 230 V 50 Hz M M Electrical diagram he auxiliary pump control must not be connected directly in parallel with the burner pump, as this would lead to excess current demand. A relay should therefore be installed, connected as shown in the diagram. pag. 12

13 Energy-saving technology OIL-FIRED INSAN 1F 25 ROOM VENILAION IMORAN: In case the INSAN GASOLIO thermal unit is mounted without the Snorkel duct for outdoor combustion air suction, it is necessary to make a hole toward outside of, at least, 180 cm 2. SNORKEL CONNECION FOR COMBUSION AIR SUCION FROM HE OUSIDE. he serial Snorkel arrangement of the INSAN GASOLIO thermal unit, allows to connect the burners air intake to the outside through an independent air duct, for the suction of the needed combustion air. Such an air duct must be sealed toward the inside room and respect the following specifications: 90 bend + 5m max of ø80mm duct length. AIR CONNECION OF GAS FLUE Combustion gases must be ducted to a chimney or to an anti-refouler equipped flue, connected to the outside, made in such a way so as to ensure a proper combustion and to avoid the gases to get in contact with walls, peoples, animals etc. Said duct must be designed so as to be in depression and/or sealed, and made of suitable, smoke-corrosion proof materials. In every point, no matter the outdoor conditions, gas temperature must not be higher than the one of dew point. he max. length of gas flue is of 5 m + a 90 bend. NOE: Flue ends must be located in such a way that exhaust gases might not cause damages in case of bad combustion. Sealed air box, soundproof, with serial SNORKEL connection. REGULAING COMBUSION WARNING: Regulation of combustion must be performed by a professionally qualified and authorised technician. INSAN 25 boiler are factory regulated by the manufacturer. In the event of further regulation being required, read the following instructions carefully Vite Locking di serraggio screw 2 - -serranda Air damper aria 3 - -manopola Knob 1 - Light the boiler ("winter" setting) and set the thermostat to maximum temperature. 2 - osition the air regulator slide according to flow rate (approximate). 3 - Set the pump pressure to the desired value (or replace the oil nozzle, see table below). 4 - Analyse combustion and regulate air flow rate accordingly by adjusting air regulator slide on the burner (having loosened the securing screw) as shown in the figure. min max 1 he sample point must be close to the boiler and the flue connection (no farther than 3-5 times the flue diameter from the boiler connection). DANFOSS oil nozzles fitted as standard on installed burners nozzle type angle atomizer type pump pressure No preheater GH 0,55 60 S 12 bar reheater GH 0,65 60 S 10 bar No preheater NOZZLE ABLE reheater GH ump pressure (bar) ,9 2 2,08 2,17 2, ,1 2,2 2,3 2,4 2,5 Oil flow rate (kg/h) GH ump pressure (bar) ,1 2,2 2,3 2, ,2 2,3 2, Oil flow rate (kg/h) pag. 13

14 OIL-FIRED INSAN 1F 25 Energy-saving technology OERAING CYCLE OF HE INSALLED BURNER MINOR INSAN burner Normal No flame hermostats hermostats Motor Motor ransformer ransformer Solenoid valve Solenoid valve Flame Flame Cutout Cutout a s a s b p b a = re-ventilation time b = re-ignition time s = Safety time p = ost-ignition time MINOR INSAN burner with preheater Normal No flame hermostats hermostats reheater Enable operation contact Motor reheater Enable operation contact Motor ransformer ransformer Solenoid valve Flame Cutout Solenoid valve Flame Cutout reheating time a s reheating time a s b p b a = re-ventilation time b = re-ignition time s = Safety time p = ost-ignition time pag. 14

15 Energy-saving technology OIL-FIRED INSAN 1F 25 YVg V ELECRICAL DIAGRAM - INSAN 25/CR boiler with oil-fired burner, no preheater Burner electrical diagram MV M 1 ~ B Yvg - Fuel solenoid valve B - Flame detector MV - Fan motor V - Burner ignition transformer BEM L1 N 1 2 S3 L1 N L2 pag. 15 CEM01.007

16 OIL-FIRED INSAN 1F 25 Energy-saving technology ELECRICAL DIAGRAM - INSAN 25/CR boiler with oil-fired burner and preheater Burner electrical diagram SCA Yvg Fuel solenoid valve B Flame detector MV MV Fan motor R Resistor SCA Ignition enable thermostat V Burner ignition transformer R YVg B V M 1 ~ BEM L1 N 1 2 S3 L1 N L2 pag. 16 CEM01.008

17 Energy-saving technology OIL-FIRED INSAN 1F 25 ELECRICAL DIAGRAM - INSAN 25/S boiler with oil-fired burner, no preheater Burner electrical diagram YVg MV V M 1 ~ ~50Hz 230V E Yvg - Fuel solenoid valve B - Flame detector MV - Fan motor V - Burner ignition transformer B L N Q BEM L1 N 1 2 S3 L1 N L2 HLB SA CONNECIONS O BE MADE BY INSALLER Q main switch (fused) Z suppressor CC circulation pump FU fuse hour meter HLB flame failure indicator SAL line switch SA room thermostat SL boiler thermostat SS safety thermostat HLCC circulation pump indicator Smin minimum temperature thermostat L1 N 1 2 S3 LANDIS LOA Z L1 N 1 2 S3 pag. 17 L1 N 1 2 S3 L1 N L2 L N CEM CC SAL BURNER ELECRICAL OWER INU h SU HLCC SS Smin SL

18 OIL-FIRED INSAN 1F 25 Energy-saving technology ELECRICAL DIAGRAM - INSAN 25/S boiler with oil-fired burner and preheater Burner electrical diagram SCA Yvg Fuel solenoid valve B Flame detector MV ~50Hz 230V E MV Fan motor R Resistor SCA Ignition enable thermostat V Burner ignition transformer R YVg B V M 1 ~ L N Q BEM L1 N 1 2 S3 L1 N L2 HLB SA CONNECIONS O BE MADE BY INSALLER Q main switch (fused) Z suppressor CC circulation pump FU fuse hour meter HLB flame failure indicator SAL line switch SA room thermostat SL boiler thermostat SS safety thermostat HLCC circulation pump indicator Smin minimum temperature thermostat L1 N 1 2 S3 LANDIS LOA Z L1 N 1 2 S3 pag. 18 L1 N 1 2 S3 L1 N L2 L N CEM CEM CC SAL BURNER ELECRICAL OWER INU h SU HLCC SS Smin SL

19 Energy-saving technology OIL-FIRED INSAN 1F 25 ~50Hz 230V E L N HLB Q SA SB B4 B ELECRICAL DIAGRAM - INSAN 25 S/A boiler with oil-fired burner, no preheater Burner electrical diagram YVg MV V M 1 ~ Yvg - Fuel solenoid valve B - Flame detector MV - Fan motor V - Burner ignition transformer B BEM I L1 N 1 2 S3 L1 N L2 JE3V M 1 ~ CONNECIONS O BE MADE BY INSALLER Q main switch (fused) Z suppressor CC circulation pump FU fuse KA KA relay contact KA relay hour meter HLB flame failure indicator SAL line switch SF flow indicator pressure switch SA room thermostat SB cylinder thermostat SL boiler thermostat SS safety thermostat JE3V 3-way motorized valve HLCC circulation pump indicator SAEI summer-winter selector SAS domestic hot water thermostat Smin minimum temperature thermostat L1 N 1 2 S3 LANDIS LOA Z pag. 19 B L1 1 2 S3 B4 N L1 N 1 2 S3 L1 N L2 L N CC SAL BURNER ELECRICAL OWER INU h SU SAS SS KA KA CEM CEM HLCC E SL Smin SAEI

20 OIL-FIRED INSAN 1F 25 Energy-saving technology ~50Hz 230V E L N HLB Q SA I ELECRICAL DIAGRAM - INSAN 25 S/A boiler with oil-fired burner and preheater Burner electrical diagram SCA Yvg Fuel solenoid valve B Flame detector MV MV Fan motor R Resistor SCA Ignition enable thermostat V Burner ignition transformer R YVg B V M 1 ~ BEM L1 N 1 2 S3 L1 N L2 JE3V M 1 ~ SB CONNECIONS O BE MADE BY INSALLER Q main switch (fused) Z suppressor CC circulation pump FU fuse KA KA relay contact KA relay hour meter HLB flame failure indicator SAL line switch SF flow indicator pressure switch SA room thermostat SB cylinder thermostat SL boiler thermostat SS safety thermostat JE3V 3-way motorized valve HLCC circulation pump indicator SAEI summer-winter selector SAS domestic hot water thermostat Smin minimum temperature thermostat B3 L1 N L2 L1 N 1 2 S3 LANDIS LOA Z pag. 20 L1 N 1 2 S3 B3 L1 N L2 L1 N 1 2 S3 L1 N L2 L N CC SAL BURNER ELECRICAL OWER INU h SU SAS SS KA KA CEM HLCC E SL Smin SAEI

21 .A.S. MINIMA 0 I.A.S. MINIMA 0 I Energy-saving technology OIL-FIRED INSAN 1F 25 ACCESS O HE BOILER H V F,,,, F V1 I INSAN INSAN V V2 S S o gain access to the inside of the boiler, proceed as follows: - Isolate the appliance from the electrical power supply and shut off the fuel valves - Detach the front panel F - Rotate the flap S downwards - Remove the screws V - Rotate the control panel downwards - For cleaning purposes, remove the fixing screws and detach the top panel H - o access electrical parts, remove screws V1 and detach the protective housing I DISMANLING HE BURNER A C C A B fig. 1 fig. 2 o dismantle the burner from the boiler, proceed as follows: - Isolate the appliance from the electrical power supply and shut off the fuel valves - Expose the interior as described above - Remove nut A and long nut B (fig. 1) using a spanner - ake out the burner (rotating in anticlockwise direction to facilitate removal) - he burner is provided with a rear bracket on which it can be supported once removed from the boiler, for ease of servicing. Attach the bracket to the flange stud, securing temporarily with nut A. When reassembling, check the burner insulating flange and replace if worn or damaged. pag. 21

22 OIL-FIRED INSAN 1F 25 Energy-saving technology WARNING: before each heating season it is advisable to have the appliance cleaned and checked by an ECOFLAM authorised technician. RELACING HE NOZZLE AND VERIYING HE OSIION OF HE ELECRODES Use a suitable wrench when replacing the nozzle, taking care not to damage the electrodes (fig. A). After fitting the new nozzle, check the position of the electrodes; the dimensions must be as indicated in figure B in order for the burner to function correctly. 2 3 mm 3 mm Fig. A Fig. B 5/6 mm MAINAINING AND CLEANING HE BOILER o keep the boiler unit in good working order, clean as instructed below. D D A B C D1 D1 F E F - Isolate the appliance from the electrical power supply and shut off the fuel valves - Expose the interior as described above - Remove the nuts D, detach the boiler top A and burner C from the boiler, and remove the baffles B - Using an appropriate brush and vacuum cleaner, clean the pipes as indicated and vacuum the dirt through the burner aperture. If necessary, detach the bottom E by loosening internal nuts D1 and removing the external bolts F. Make sure parts are reassembled in the correct order. Inspect all seals removed, and replace if damaged or worn. Make certain the baffles fit snugly in the pipes when reinstated. pag. 22

23 Energy-saving technology OIL-FIRED INSAN 1F 25 EXLODED DRAWING OF HE CONROL ANEL INSAN.A.S. MINIMA I /A mod. S ref. description code 1 emperature and pressure gauge G Circulation pump indicator E15.09/1 3 Winter/Summer selector * R /A lastic cap (S Model) R10.13/1 4 Main 0/I switch R Fuse holder E8.02/2 Fuse E Boiler thermostat G8.15/1 7 Safety thermostat, manual reset G8.08/2 8 Control unit A1.17/1 9 Control unit housing A Control unit bracket CFA19.105/ Minimum temperature thermostat G Domestic hot water thermostat* G8.02 * CR and S/A models only pag. 23

24 , OIL-FIRED INSAN 1F 25 Energy-saving technology EXLODED DRAWING OF INSAN 25 CR /D 6 22/C /A 22/B 22/F art. A A 22/A /E 2 12/A /A 18 17/A /A 27 pag. 24

25 Energy-saving technology OIL-FIRED INSAN 1F 25 ref. description code 1 Boiler unit CFA Boiler insulation CFA Bottom boiler top seal J7.18/4 4 Bottom boiler top insulation CFA Bottom boiler top CFA04.303/001 6 op boiler top insulation support net CFA op boiler top insulation CFA op boiler top CFA04.304/001 9 Baffles CF Automatic air vent valve G2.07/1 11 Sensor holder CFA hermostats: boiler safety domestic hot water minimum temperature 12A hermometer 13 Drain valve S System flow pipe CF01.102/ hree way valve assembly GR.RUB.02 15A Microswitch assembly V1.39/2 16 Return valve assembly GR.RUB High-pressure pipe CF A Low-pressure pipe CF late heat exchanger G13.25/2 18/A O ring Y6.01/29 19 Circulation pump 1.42/3 20 System return pipe CF01.101/ Expansion tank G Burner of Kerosene /830 22/A Clip E22.06/1 22/B Flexible tube S9.51/2 22/C Collar CFA /D Stainless steel terminal O /E 22/F KI.INS 23 Burner insulation flange BFG Sight glass seal CFG01.027/1 25 Sight glass CFA Sight glass nut CFA Safety valve G ressure sensor pag. 25

26 , OIL-FIRED INSAN 1F 25 Energy-saving technology EXLODED DRAWING OF INSAN 25 S - S/A /D 6 20/C 9 20/A /B 20/F art. A A 20/A 20/E /A pag. 26

27 Energy-saving technology OIL-FIRED INSAN 1F 25 ref. description code 1 Boiler unit CFA Boiler insulation CFA Bottom smoke hood seal J7.18/4 4 Bottom smoke hood insulation CFA Bottom smoke hood CFA04.303/001 6 op smoke hood insulation support net CFA op smoke hood insulation CFA op smoke hood CFA04.304/001 9 Baffles CF Automatic air vent valve G2.07/1 11 Sensor holder CFA hermostats: Boiler safety minimum 12A hermometer 13 Drain valve S System flow pipe CF01.104/ ump/boiler connecting pipe CF01.106/ Circulation pump 1.42/3 17 System return pipe CF01.105/ Safety valve G Expansion tank G Burner of Kerosene /830 20/A Clip E22.06/1 20/B Flexible tube S9.51/2 20/C Collar CFA /D Stainless steel terminal O /E 20/F 21 Burner insulation flange BFG Sight glass seal CFG01.027/1 23 Sight glass CFA Sight glass nut CFA ressure sensor 26 Ring nut 3/4' BF01.108/1 27 Ring nut 1/2' BF pag. 27

28 0 I OIL-FIRED INSAN 1F 25 Energy-saving technology EXLODED DRAWING OF INSAN 25 CR, S AND S/A CASING INSAN.A.S. MINIMA ref. description code 1 Boiler frame CFA09.103/012 2 op panel CFA12.050/018 3 Side panel CFA12.028/018 4 Upper cross member CFA19.107/001 5 Bottom panel CFA19.104/012 6 Lower cross member CFA19.101/001 7 Control panel protective housing CFA Control panel CFA Front panel CFA12.026/ Flap CFA12.048/018 pag. 28

29 Energy-saving technology OIL-FIRED INSAN 1F MINOR INSAN pag. 29

30 OIL-FIRED INSAN 1F 25 Energy-saving technology MINOR R INSAN pag. 30

31 Energy-saving technology OIL-FIRED INSAN 1F 25 MINOR INSAN 25 MINOR R INSAN 25 ref. description code code 1 Cast burner casing BFF04.318/011 BFF04.318/011 2 Burner casing cover BFC09.002/11 BFC09.002/11 3 Ignition transformer 1.23/ Fan rotor BFV10.001/001 BFV10.001/001 5 Motor flange BFF03.005/001 BFF03.005/001 6 Capacitor C1.07/8 C1.07/8 7 Electric motor M1.10/3 M SUNEC fuel oil pump DANFOSS fuel oil pump 1.21/3 1.21/3 9 SUNEC core DANFOSS core V4.12/1 V4.12/1 10 SUNEC coil DANFOSS coil V5.10/3 V5.10/2 11 ump connector BFR01.103/001 BFR01.103/ Flexible tube S9.52/11 S9.52/2 13 Fuel oil filter S1.06/1 S Duct BFC BFC Air intake BFC BFC Nozzle assembly GR.0101/ Diffuser BFB01.005/002 BFB01.005/ Ignition cable BFE01.301/1 BFE01.301/1 19 Nozzle assembly support rod BFA05.109/001 BFA05.005/ reheater assembly - GR.CR.009/5 21 Ignition electrodes BFE BFE Nozzle U1.0.75/60S U1.0.65/60S 23 Flame detector A2.07/1 A2.07/1 24 Flame detector mounting A2.08/1 A2.08/1 25 Nozzle holder GR.CR.009/2 BFC10.002/1 26 Seal - BF04.013/1 27 hermostat - E Fuel preheater element - R1.05/1 29 Air shutter BFS01.002/001 BFS01.002/ External regulation plate BFS BFS Internal regulation plate BFS BFS pag. 31

32 ECOFLAM S.p.A. reserves the right to make such modifications to products as are deemed necessary or useful without significantly altering the broad specifications. Ecoflam S.p.A. via Roma, RESANA (V) - Italy - tel. 0423/ r.a. - telex ECOFLA I - telefax 0423/715444

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder TRIANCO Oil TRIANCO - OIL BURNER BURNER DETAILS EuroStar Range To be retained by householder TECHNICAL DATA NOZZLE OUTPUT MODEL Output Burner Nozzle Pump Model pressure CO 2 (%) EUROSTAR UTILITY 50/65

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head

More information

Single stage operation oil burner

Single stage operation oil burner Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

15 20 kw kw kw

15 20 kw kw kw Burner Set-up Details 15 20 kw 20 26 kw 29 36 kw Riello RDB2 Please read these instructions carefully before commissioning and using this appliance. To be retained by the householder HEALTH AND SAFETY

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded

More information

Single stage operation oil burner

Single stage operation oil burner Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow

More information

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual. Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual. The package of the 2R GT OF boiler contains instructions for installation, operation and

More information

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its diesel-burning boilers are produced in accordance with the requirements of article 3 paragraph 3 of Directive PED 97/23/EEC

More information

Columbia Boiler Company

Columbia Boiler Company EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

More information

Utility and Utility System Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

Utility and Utility System Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION! Grant Vortex Eco Utility and Utility System Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION! LOW Nox yellow flame (riello rdb 2.2 bx) burner fitted The Grant

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150 Wall Mounted Fan Flue System boiler Appr. nr. B 94.04 A - CE 0063 AQ 2150 Phone numbers: Installer Service Engineer Serial N Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS Please read

More information

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A 178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

More information

External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION! Grant Vortex Pro External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION! LOW Nox yellow flame (riello rdb 2.2 bx) burner fitted The Grant Vortex

More information

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) FOR USE WITH MODEL: OH6FX072DV4 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Corn Flame Energy Corn Stove Model 3000

Corn Flame Energy Corn Stove Model 3000 Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,

More information

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 NOT FOR DOMESTIC USE SPACE HEATING ONLY Made By: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia

More information

User's Instructions. Alpha CB50

User's Instructions. Alpha CB50 User's Instructions Alpha CB50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler with Unvented Hot Water Storage (From Boiler Serial No. 27B32500001) For Technical help or for Service

More information

Wall hung combination boilers. This is a CAT II2H3+ appliance USER, INSTALLATION AND SERVICING INSTRUCTIONS SUPPORTED BY

Wall hung combination boilers. This is a CAT II2H3+ appliance USER, INSTALLATION AND SERVICING INSTRUCTIONS SUPPORTED BY Wall hung combination boilers This is a CAT II2H3+ appliance SUPPORTED BY USER, INSTALLATION AND SERVICING INSTRUCTIONS Index Introduction... 3 User instructions...3 Introduction... 4 Controls and lighting...

More information

REMKO CLK Mobile automatic heater

REMKO CLK Mobile automatic heater REMKO CLK Mobile automatic heater Operation Technology Spare Parts Edition GB M04 REMKO - powerful like a bear. Operating Instructions Read these instructions carefully before setting up/operating the

More information

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) www.windsterhood.com User s Manual LINER SERIES WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00 Ca 6s and BCa 6s 33-64 kw INSTALLATION AND OPERATING INSTRUCTIONS Page 1 CONTENTS: General specification Dimensions for Ca6s and BCa6s boilers. Boiler room clearance requirements Boiler block assembly

More information

A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFI A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of

More information

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS G 2000-S 25-35 - 45-55 60-70 - 100 (V13) 1 Index WARNINGS GAS FLOW RATE DIMSIONS SETTINGS PARAMETERS SERVICING THE URNER 3 8 13 OPERATING DESCRIPTION

More information

Alpha CombiMax 350 and 600

Alpha CombiMax 350 and 600 Installation and Servicing Instructions Alpha CombiMax 350 and 600 Unvented Hot Water Store for use with the Alpha 240/280 Range of Gas Fired Combination Boilers For Technical help or for Service call...

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Servicing Instructions Type C Boilers G.C.N: 4-6-0 47-6-08 47-6-09 47-6-3 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of Parts 3.2

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

Synergy Grill User & Engineer Installation & Conversion Guide

Synergy Grill User & Engineer Installation & Conversion Guide Synergy Grill 1300 User & Engineer Installation & Conversion Guide 1 Index: Description Page Number/Section Important Information 3 Installation 4-6 / Section 1 Commissioning 6 / Section 2 Converting Gas

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

POWER SHOWERS Models 4500M 5002M 4500T 5002T

POWER SHOWERS Models 4500M 5002M 4500T 5002T II POWER SHOWERS Models 4500M 5002M 4500T 5002T Performance Shower Products CUSTOMER SERVICE HELPLINE: 01883 730339 CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY: This booklet covers all models in

More information

User Manual for model

User Manual for model User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO

More information

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB / GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

Waste/Multi Oil Boilers from Flexiheat

Waste/Multi Oil Boilers from Flexiheat Waste/Multi Oil Boilers from Flexiheat At a time of rising fuel costs, the Flexiheat FMOB universal/waste oil boiler range, which can burn nearly all vegetable, animal, conventional and waste oil, will

More information

SECTION AUXILIARY HEATER

SECTION AUXILIARY HEATER 14-301.03/ 1 2010MR12 SECTION 14-301.03 GENERAL DESCRIPTION The Thermo 300 auxiliary heating system is used in conjunction with the vehicle s heating system, in order to heat the passenger compartment

More information

AUS. Format 34I-34E BF

AUS. Format 34I-34E BF AUS Format 34I-34E BF Installation and servicing instructions CONTENTS 1 TECHNICAL FEATURES AND DIMENSIONS..................................................... 2 2 GENERAL REQUIREMENTS FOR INSTALLATION.................................................

More information

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only. www.windsterhood.com User s Manual UNDER CABINET SERIES RA-3030SS RA-3036SS NOTE: This unit was designed for indoor residential use and DUCTED operation only. DO NOT USE OVER A WOOD GRILL OR MOUNT OUTDOOR

More information

TAHITI CONDENSING KR 55 - KR 85

TAHITI CONDENSING KR 55 - KR 85 IST 03 C 351-01 TAHITI CONDENSING KR 55 - KR 85 GB INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully. They will

More information

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual UNDER CABINET SERIES WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45 U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Opus 800 Gas Boiling Tops OG8003, OG8004 & OG8009 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:

More information

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by

More information

User s Manual WS-5830SS WS-5836SS WS-5842SS

User s Manual WS-5830SS WS-5836SS WS-5842SS www.windsterhoocom UNDER CABINET SERIES User s Manual WS-5830SS WS-5836SS WS-5842SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit

More information

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS. TABLE OF CONTENTS 1 Table of Contents www.windsterhood.com Safety Information... 2 3 WALL MOUNT SERIES User s Manual RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS NOTE: PLEASE

More information

MAINTENANCE AND SERVICE GUIDE

MAINTENANCE AND SERVICE GUIDE c Dimensions MAINTENANCE AND SERVICE GUIDE System II 80 and 100 Central Heating Fanned Flue Boiler Sizes in mm Flue types: C 12 or 42: horizontal C 32 xx: vertical concentric C 32 xy: Twin flue Boiler

More information

ST 40 Oil Burner. Installation & Maintenance Manual

ST 40 Oil Burner. Installation & Maintenance Manual ST 40 Oil Burner Installation & Maintenance Manual 178 093 13 Thank you for choosing a Nu-way burner. As you would expect from a Company who has a pedigree of more than 75 years in the heating industry,

More information

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers User's Instructions Alpha CD5X/8X Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21 Part No. DOC 38 Rev. 02 January 2007 SUPPLEMENTARY INSTALLATION and SERVICING INSTRUCTIONS Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21 For use with Kerosene only

More information

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R 178 013 03-2 2016-05-26 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 10 E R DESCRIPTION Components 1. Scale, nozzle assembly 2. Nozzle assembly adjustment

More information

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler Wall hung, fanflue, roomsealed, high efficiency gas boiler Service manual Riva Plus HE Models G.C. ppl. No. M296.24SR/C 41-583-18 System boiler M296.28SR/C 41-583-19 System boiler Leave this manual adjacent

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

HEATING AND VENTILATION

HEATING AND VENTILATION SECTION 14-102.04 14-102.04/ 1 2007OC19 DESCRIPTION The heating, ventilation and air conditioning (HVAC) system is designed to optimize passenger comfort. The system regulates interior vehicle atmosphere,

More information

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

WHU WATER HEATING UNITS.  GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS WHU WATER HEATING UNITS GENERAL MANUAL MODEL KEY WHU Water Heating Unit Maximum heating power, kw Max. water inflow pressure, bar Voltage options GENERAL INFORMATION WHU water heater, producing hot water

More information

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents

More information

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents

More information

Universal fuel unit for oil burners

Universal fuel unit for oil burners Universal fuel unit for oil burners Type U www.deltapumps.com European patent Certified Quality System rinted in Italy - DE115/0404 Universal Fuel Unit for oil burners Type U The DETA Universal Fuel Unit

More information

Proline GAS HOB Model TCG40IX Instruction Book

Proline GAS HOB Model TCG40IX Instruction Book Proline GAS HOB Model TCG40IX Instruction Book GB Operating and Installation Instructions Index Technical data and specifications...... 3 Installation...................... 3-6 Ventilation........................

More information

Rif Cod i220-0

Rif Cod i220-0 15 52 50 6 13 53 51 2 9 8 3 20 19 18 5 1 7 14 10 4 17 Rif Cod 1 0010060 2 0060287 3 0060310 4 0080003 5 0080004 6 0080051 7 0080053 8 0080410 9 0080413 10 0080430 11 0080432 12 0080434 13 0080435 14 0080436

More information

Infrared Diesel Heater

Infrared Diesel Heater Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the

More information

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A 178 017 55-1 2016-05-19 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 45A DESCRIPTION Components 1. Flame cone 2. Ignition electrodes 3. Nozzle assembly

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National

More information

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No 53 416 06 Publication No. ZZ 180/17 May 2000 These appliances are tested and certified by B G Technology for

More information

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE IST 03 C 202-01 ELBA DUAL INSTALLATION, USE AND MAINTENANCE GB Thank you for choosing our boilers. Please read these installation and maintenance instructions with care. Please note that the boiler must

More information

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH. 178 024 63-2 2016-11-22 Providing sustainable energy solutions worldwide Installation- and maintenance instruction MOL1650 T3N 323 2FH No control DISCRIPTION Components 2 3 4 5 6 7 8 9 18, 19 13 10 17

More information

Sorrento & Flamevector Fireplace Boilers

Sorrento & Flamevector Fireplace Boilers orrento & Flamevector Fireplace Boilers ection 10. Fitting Instructions 10.1 Positioning the Boiler 10.2 Ventilation 10.3 lectrical 10.4 Combustion Air (Conventional Flue Models) 10.5 Water Connections

More information

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhoocom UNDER CABINET SERIES User s Manual WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS CGM-04/392 ER-0170/1996 Thank you for choosing a DOMUSA TEKNIK heating boiler. You have chosen a boiler which will provide the ideal level of comfort

More information

Chapter 3 Cooling, heating and ventilation systems

Chapter 3 Cooling, heating and ventilation systems 3 1 Chapter 3 Cooling, heating and ventilation systems Contents Antifreeze mixture..............................see Chapter 1 Cooling fan assembly - testing, removal and refitting.............8 Cooling

More information

Integrated Ventilation System

Integrated Ventilation System Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

RETROFIT APPLICATIONS ONLY

RETROFIT APPLICATIONS ONLY Installation & Operating Manual WARNING RETROFIT APPLICATIONS ONLY If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow the installation and set-up instructions

More information

OIL FIRED COOKERS & BOILERS

OIL FIRED COOKERS & BOILERS REPLACEMENT PARTS 1. BOILER BURNER ECOFLAM PART NO A. COMMON PARTS Mounting Gasket 18.04.001 Oil Pump Danfoss BFP 11R3 0.0.000 Flexible Oil Line 740mm 1 /4 BSP Braided 01.0.300 Control Box Landis and GYR

More information