TEST REPORT: CHM14-07-CHY

Size: px
Start display at page:

Download "TEST REPORT: CHM14-07-CHY"

Transcription

1 A TEST REPORT: CHM14-07-CHY Date: Tel: Fax: Client s Ref: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the terms set out within this report. SUBJECT Test of Naturion Ioniser NA50 for Its Performance of Clean Air Delivery Rate (PM2.5, PM10) CLIENT Serumi International Private Limited 36 Armenian Street #02-02 Singapore Attn: Mr Sean Gan PY TEST DATE 23 March 2015 DESCRIPTION OF VACCUM CLEANER The photograph and specifications of Naturion Ioniser NA50 were listed in Annex A. METHOD OF TEST The Naturion Ioniser NA50 was tested in a chamber of 200 L (Annex B); Initial particular matter concentrations were adjusted to around 400 µg/m 3 to 450 µg/m 3 for PM2.5 and PM 10; Fan was powered on during ioniser operation; The PM2.5 and PM10 concentrations were monitored under conditions with and without Naturion Ioniser NA50 operation. AHAM AC Method for Measuring Performance of Portable Household Electric Room Air Cleaners was used as a reference (Annex C). Laboratory: TÜV SÜD PSB Pte. Ltd. No.1 Science Park Drive Singapore Phone : Fax : testing@tuv-sud-psb.sg Co. Reg : R Regional Head Office: TÜV SÜD Asia Pacific Pte. Ltd. 3 Science Park Drive, #04-01/05 The Franklin, Singapore

2 RESULTS 1. PM 2.5 Removal Performance The results of PM2.5 removal performance were listed in Table 1 and plotted in Figure 1. Table 1 PM2.5 removal performance of Naturion Ioniser NA50 (unit: µg/m 3 ) Time, Minutes PM 2.5- without Naturion Ioniser NA50 Operation (Natural Decay) PM2.5- with Naturion Ioniser NA50 Operation Figure 1 Schematic diagram of PM2.5 removal performance by Naturion Ioniser NA50 Page 2 of 10

3 RESULTS (Continued) 2. PM 10 Removal Performance The results of PM10 removal performance were listed in Table 2 and plotted in Figure 2. Table 2 PM10 removal performance of Naturion Ioniser NA50 (unit: µg/m 3 ) Time, Minutes PM10- without Naturion Ioniser NA50 Operation (Natural Decay) PM10- with Naturion Ioniser NA50 Operation Figure 2 Schematic diagram of PM10 removal performance by Naturion Ioniser NA50 Page 3 of 10

4 RESULTS (Continued) 3. Calculation of Clean Air Delivery Rate (CADR) By referring to AHAM AC Method for Measuring Performance of Portable Household Electric Room Air Cleaners, the Clean Air Delivery Rate (CADR) in terms of PM2.5 and PM10 removal was calculated by: CADR = V chamber (K ioniser K natural decay ) (Annex C) Where V chamber = 200 litres K ioniser = linear regression of Ln (PM2.5/PM10- Naturion Ioniser NA50 Operation) Vs Time K natural decay = linear regression of Ln (PM2.5/PM10- Natural decay) Vs Time The CADR calculation result were listed in Table 3 and Table 4 Table 3 CADR of Naturion Ioniser NA50 in terms of PM 2.5 removal Values V chamber, litres 200 K ioniser, 1/minute (R 2 = 0.97) K natural decay, 1/minute (R 2 = 0.99) CADR (in terms of PM 2.5 removal), litres/minute CADR (in terms of PM 2.5 removal), litres/hour 2,470 Table 4 CADR of Naturion Ioniser NA50 in terms of PM 10 removal Values V chamber, litres 200 K ioniser, 1/minute (R 2 = 1.00) K natural decay, 1/minute (R 2 = 0.99) CADR (in terms of PM10 removal), litres/minute CADR (in terms of PM10 removal), litres/hour 3,611 Page 4 of 10

5 DISCUSSION The PM2.5 concentrations decreased from 418 µg/m 3 to 7 µg/m 3 in a 200 litre chamber after 15 minutes operation of Naturion Ioniser NA50 or decreased by 98.3%. The PM10 concentrations decreased from 445 µg/m 3 to 2 µg/m 3 in a 200 litre chamber after 15 minutes operation of Naturion Ioniser NA50 or decreased by 99.6%. The Clean Air Delivery Rate (CADR) of Naturion Ioniser NA50 in terms of PM2.5 removal was calculated to be litres/minute or 2,470 litres/hour. The Clean Air Delivery Rate (CADR) of Naturion Ioniser NA50 in terms of PM10 removal was calculated to be litres/minute or 3,611 litres/hour. DR. YANG LEI EXECUTIVE CONSULTANT DR CHEN HUAYI ASSISTANT VICE PRESIDENT CHEMICAL CENTRE Page 5 of 10

6 Annex A: Naturion Ioniser NA50 Specifications (Provided by Serumi International Private Limited) Name Naturion Ioniser NA50 Photograph Negative ions count Power supply Net Weight Unit dimensions Unit with clip dimensions Packaging dimensions Max pcs/cm 3 (at 100 cm distance) DC 12V 43 g mm mm mm Page 6 of 10

7 Annex B: Schematic of test chamber Particulate analyzer NA50 Wind direction Figure 3 Schematic layout of the test chamber (200 litres) Page 7 of 10

8 Annex C: CADR Calculation method (by referring to AHAM AC Section 8: Method for measuring performance of portable household electric room air cleaners) Page 8 of 10

9 Page 9 of 10

10 Please note that this Report is issued under the following terms : 1. This report applies to the sample of the specific product/equipment given at the time of its testing/calibration. The results are not used to indicate or imply that they are applicable to other similar items. In addition, such results must not be used to indicate or imply that TÜV SÜD PSB approves, recommends or endorses the manufacturer, supplier or user of such product/equipment, or that TÜV SÜD PSB in any way guarantees the later performance of the product/equipment. Unless otherwise stated in this report, no tests were conducted to determine long term effects of using the specific product/equipment. 2. The sample/s mentioned in this report is/are submitted/supplied/manufactured by the Client. TÜV SÜD PSB therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture, consignment or any information supplied. 3. Nothing in this report shall be interpreted to mean that TÜV SÜD PSB has verified or ascertained any endorsement or marks from any other testing authority or bodies that may be found on that sample. 4. This report shall not be reproduced wholly or in parts and no reference shall be made by the Client to TÜV SÜD PSB or to the report or results furnished by TÜV SÜD PSB in any advertisements or sales promotion. 5. Unless otherwise stated, the tests were carried out in TÜV SÜD PSB Pte Ltd, No.1 Science Park Drive Singapore July 2011 Page 10 of 10

TEST REPORT: CHM14-05-CHY

TEST REPORT: CHM14-05-CHY A TEST REPORT: 7191100863-CHM14-05-CHY Date: Tel: +65 68851291 Fax: +65 67784301 Client s Ref: Email: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations

More information

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,

More information

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine: January 26, 2005 Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT 06824 Dear Mr. Sunshine: We appreciate the opportunity to be of service to you. Please find enclosed one bound copy of Intertek

More information

Test Report No EEC12/08 dated 18 Jun 2012

Test Report No EEC12/08 dated 18 Jun 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is

More information

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization Client: IZEN Co., Ltd. 242, Aegibong-ro, Wolgot-myeon Gimpo-si, Gyeonggi-do 415-873 REPUBLIC OF KOREA Contact Person: ISA AC Kim Tel.: +82-31-999-7300, 070-4705-1878 Fax.: +82-31-997-3147 Manufacturing

More information

Our Ref: CD/FSSD/12/02/03/01 DID: FAX:

Our Ref: CD/FSSD/12/02/03/01 DID: FAX: Our Ref: CD/FSSD/12/02/03/01 DID: 68481407 FAX: 68481493 14 Jan 2010 Registrar, Board of Architects (BOA) Registrar, Professional Engineers Board (PEB) President, Singapore Institute of Architects (SIA)

More information

Country Report for Solomon Islands

Country Report for Solomon Islands IIEC International Institute for Energy Conservation Country Report for Solomon Islands Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon

More information

SmartSensor 105 & Advance NEMA External Ice

SmartSensor 105 & Advance NEMA External Ice SmartSensor 105 & Advance NEMA External Ice Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA external

More information

The smart handling of liquid chemicals: quickly connected safely dispensed.

The smart handling of liquid chemicals: quickly connected safely dispensed. The smart handling of liquid chemicals: quickly connected safely dispensed. Now you can bid farewell to the hazards of conventional drum emptying. ESCAPING GAS! Escaping gases, vapours and particulates

More information

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio: August 3, 2010 Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2 Dear Mr. Sterio: RTI is pleased to submit this letter report to Surgically Clean Air, Inc on our project

More information

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7 WRc Evaluation & Testing Centre Ltd Test Code Sheet Number 1 2 1 1 17 WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October 1999 Sheet 1 of 7 TEST CODE SHEET 1. TYPE OF TEST(S) Performance

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION Particle Sensor 550 Issue D FEATURES Laser-based light scattering particle sensing Datasheet Concentration range: 0 µg/m to,000 g/m Fully calibrated EMC: Heavy industrial level IEC6000 Response time:

More information

The smart handling of liquid chemicals: quickly connected safely dispensed.

The smart handling of liquid chemicals: quickly connected safely dispensed. The smart handling of liquid chemicals: quickly connected safely dispensed. Now you can bid farewell to the hazards of conventional drum emptying. ESCAPING GAS! Escaping gases, vapours and particulates

More information

SUPPLEMENT REPORT No.: XPL/13600/

SUPPLEMENT REPORT No.: XPL/13600/ (Pty) Ltd Certex Appointed Ex Laboratory Reg No: 1999/027771/07 Government Approved Test Laboratory (Previously AIA) T0104 7 Spanner rd, PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11)

More information

Country Report for Tonga

Country Report for Tonga IIEC International Institute for Energy Conservation Country Report for Tonga Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands

More information

Installation Instructions for the

Installation Instructions for the Installation Instructions for the Particle Sensors General Information The Honeywell Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the

More information

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism Object A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism 2153-16 Type TCB 145-40-31 Serial No. 16000702, 16000703

More information

Measurement of Safety Integrity of E/E/PES according to IEC61508

Measurement of Safety Integrity of E/E/PES according to IEC61508 Measurement of Safety Integrity of E/E/PES according to IEC61508 Mr. Chen Zhenkang TUV Rheinland Singapore 18. May. 2018 Singapore World Metrology Day 2018 1 Agenda 1. TÜV Rheinland: a Certification Body

More information

This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094.

This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094. This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094. They are not intended to replace the regulations nor to provide

More information

Country Report for Kiribati

Country Report for Kiribati IIEC International Institute for Energy Conservation Country Report for Kiribati Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands

More information

Air Purifier Test Report (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001

Air Purifier Test Report (Brand: Plasma Air Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001 PLASMA AIR INTERNATIONAL 36 Connecticut Ave Suite 13 Norwalk, CT 6954 Attn: Larry Sunshine (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 12C) Our Reference No.: Prepared by: LAWN ENVIRONMENTAL

More information

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements

More information

COA-2010-F Electronic CO 2

COA-2010-F Electronic CO 2 COA-2010-F Electronic Analyzer New electronic analyzer specifically designed to monitor and temperature for the verification of in research and pharmaceutical markets. This unit has been developed to incorporate

More information

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Will Yahr Site: Big Bend NP - (BIBE-KB) Service Date(s): 7/26/217

More information

Component Description Quantity Storage. Glass Slide 75 mm x 25 mm glass slide C. Storage Case Storage case for the glass slide C

Component Description Quantity Storage. Glass Slide 75 mm x 25 mm glass slide C. Storage Case Storage case for the glass slide C Package Insert QuantiGene View Temperature Validation Kit Cat. No. QV0523 Product Overview The QuantiGene View Temperature Validation Kit uses a National Institute of Standards and Technology (NIST) calibrated

More information

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION HPM Series Particle Sensor DESCRIPTION The Honeywell HPM Series Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the concentration range of

More information

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Mike Slate Site: Canyonlands National Park (CANY-IS) Service Date(s):

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :DH1510130042A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company Address :GradConn Ltd. :No. 139 Wuhan Rd., Longtan Township, Taoyuan County, Taiwan Sample Name :Refer to see page 2

More information

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Jake Zaragoza Site: Big Bend NP (BIBE-KB) Service Date(s): 2/21/217

More information

Country Report for Niue

Country Report for Niue IIEC International Institute for Energy Conservation Country Report for Niue Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands

More information

Our Ref: SCDF/HAZ/14/03/02/01 DID: FAX: REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE

Our Ref: SCDF/HAZ/14/03/02/01 DID: FAX: REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE Our Ref: SCDF/HAZ/14/03/02/01 DID: 68483312 FAX: 68483318 6 th December 2011 See Distribution Dear Sir/Madam, REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE Since September 2009, a multi-agencies

More information

Rotary Screw Compressors UP5 Series kw

Rotary Screw Compressors UP5 Series kw Rotary Screw Compressors UP5 Series 11-37 kw Rotary Screw Compressors UP5 Series 11-37 kw Boost Your Profitability Boosting your company s profits was the main goal that Ingersoll-Rand had in mind when

More information

FIRE TESTING SERVICES FIRE TESTING SER

FIRE TESTING SERVICES FIRE TESTING SER FIRE TESTING SERVICES At TUV SUD PSB, we have a fire testing laboratory that was established since the late 70 s. We provide fire tests and inspection services for various industries, both locally and

More information

We Identify and S.T.O.P. Your Noise Problems

We Identify and S.T.O.P. Your Noise Problems ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October

More information

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION Particle Sensor 32322550 Issue C FEATURES Laser-based light scattering particle sensing Datasheet Concentration range: 0 µg/m 3 to 1,000 µg/m 3 Fully calibrated EMC: Heavy industrial level IEC61000 Response

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen d.c. or a.c.

More information

Country Report for Fiji

Country Report for Fiji I I E C International Institute for Energy Conservation Northern Marianas Country Report for Fiji Palau Guam Federated States of Micronesia Marshall Islands Kiribati Papua New Guinea Nauru Solomon Islands

More information

ENGINEERING EVALUATION

ENGINEERING EVALUATION ENGINEERING EVALUATION REPORT NUMBER: 100378137MID-002 ORIGINAL ISSUE DATE: April 26 th, 2011 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett

More information

FIRESTOP INSPECTION. Dr. Selina LIN. Technical Manager August 01, FS Inspection 1

FIRESTOP INSPECTION. Dr. Selina LIN. Technical Manager August 01, FS Inspection 1 FIRESTOP INSPECTION Dr. Selina LIN Technical Manager August 01, 2017 FS Inspection 1 HILTI IN FIGURES Operations in more than 120 countries 23,385 employees (at the end of 2015) 120 nationalities in the

More information

Refrigerating Appliance ErP Test Report

Refrigerating Appliance ErP Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)

More information

A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator

A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator R. Jagan 1, R. GokulaKrishnan 2, S. Ramar 3, S. Manikandan 4, D.R.P. Rajarathnam 5 1,2,3 Student, Department

More information

Acoustic Verification Report

Acoustic Verification Report Acoustic Verification Report Invacare XPO 2 Portable Oxygen Concentrator Type XPO100B-EU for Date: 2013-12-10 Our reference: IS-ATC2-MUC/js Document: Report Invacare VR.600010074.002.12 - Revision 2.docx

More information

Guidelines for the Evaluation of Direct Reading Monitors

Guidelines for the Evaluation of Direct Reading Monitors Guidelines for the Evaluation of Direct Reading Monitors ER Kennedy, ML Woebkenberg, PC Schlecht, DL Bartley, S Shulman, HA Feng, R Song NIOSH C Cowherd, Jr., MA Grelinger, and KM Bauer Midwest Research

More information

Experimental Investigation of Purification Function of Air Conditioner

Experimental Investigation of Purification Function of Air Conditioner Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 10 Experimental Investigation of Purification Function of Air Conditioner Qi

More information

TESTS OF ADSIL COATING

TESTS OF ADSIL COATING TESTS OF ADSIL COATING Test B - Long Term Test FSEC-CR-1259-01 July 11, 2001 Prepared for: Bob Suggs Florida Power & Light Company 9250 W. Flagler Street Miami, Florida 33174 Principal Investigator Dr.

More information

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW & e. INDUSTRIAL LOSS CONTROL & eng Analisi e Controllo dei Rischi Industriali HUGHES ASSOCIATES EUROPE, srl FIRE SCIENCE & ENGINEERING BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT

More information

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1 REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.

More information

Technical-Report for SL Lamp 5 W

Technical-Report for SL Lamp 5 W Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S

More information

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

METZIN Bearing Induction Heater. Operating Instructions

METZIN Bearing Induction Heater. Operating Instructions METZIN Bearing Induction Heater Operating Instructions Model: MIH-8.0/ S Specifications and chassis color subject to change without notice. METZIN Technologies & Consulting Pte Ltd. Tel: +65 6898 2957

More information

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Guidelines accompanying:

Guidelines accompanying: EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR ENERGY Directorate C - Renewables, Research and Innovation, Energy Efficiency C.3 - Energy efficiency Guidelines accompanying: Commission Delegated Regulation

More information

UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units

UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units Part 3: Recirculation UVGI Systems, Zonal Protection Factor, In-place testing Protocols Dr. Wladyslaw Jan Kowalski, PE, Immune Building

More information

AUDITORY SYSTEMS LABORATORY HEARING PROTECTION DEVICE ATTENUATION TEST REPORT

AUDITORY SYSTEMS LABORATORY HEARING PROTECTION DEVICE ATTENUATION TEST REPORT AUDITORY SYSTEMS LABORATORY HEARING PROTECTION DEVICE ATTENUATION TEST REPORT! AUDITORY SYSTEMS LABORATORY GRADO DEPT. OF INDUSTRIAL & SYSTEMS ENGINEERING Dr. John G. Casali, Professor and Director COLLEGE

More information

Review Fire Test Report

Review Fire Test Report Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of

More information

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement RN53 Radon Detector RN53 - For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement Description The RN53 Radon Detector operates on the method of electrostatic collecting of the radon

More information

LAC52 Smart Car Air Purifier

LAC52 Smart Car Air Purifier IB-00-LAC0-0 V. Designed in Finland International Limited Manufactured by Dongguan LIFAair Technology Ltd. Address: No., East Industry Road, Songshan Lake Science & Technology Industrial Park, Dongguan,

More information

Clean Air Optima HEPA UV ionizer air purifier CA-508

Clean Air Optima HEPA UV ionizer air purifier CA-508 Clean Air Optima HEPA UV ionizer air purifier CA-508 Manual Read these instructions carefully before you start using the air purifier and keep the manual for later usage. Copyright : Clean Air Optima 1

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) JÄ TÜVF=heinland`:.ä;' Preci ely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000038506 02 AMs designation: lvlanufacturer: Test Laboratory: Modell 6888Afor02 Rosemount l nc. 8200

More information

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,

More information

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Mr. Corrado Maltese, B.Sc., C.R.S.P Senior Manager, Occupational Health and Safety Department

Mr. Corrado Maltese, B.Sc., C.R.S.P Senior Manager, Occupational Health and Safety Department Toronto Catholic District School Board Catholic Education Centre 80 Sheppard Avenue East North York, Ontario M2N 6E8 Attention: Mr. Corrado Maltese, B.Sc., C.R.S.P Senior Manager, Occupational Health and

More information

Infrastructure Technology

Infrastructure Technology Registered Testing Authority - CSIRO 26 June 2014 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7086.4s Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 24 June 2014 Manufacturer:

More information

- Full test except clause (IPX1 IPX2) (Oxygen bomb test) and annex ต

- Full test except clause (IPX1 IPX2) (Oxygen bomb test) and annex ต Laboratory name Japan Electrical Testing Laboratory (Thailand) Co., Ltd. Address 46/173 Nuanchan Road, Nuanchan, Bueng Kum, Bangkok 1. A.C. electric fans - TIS 934-2533 (1990) - TIS 934-2558 (2015) 2.

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev. STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart

More information

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07 RF TEST REPORT Applicant FCC ID Brand Product ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS Model VFD 511 Multi-Mode Digital Mobile Phone Report No. RXC1703-0087RF07 Issue Date May 24,2017 TA Technology

More information

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 56 Jackson Street Aurora, Illinois 60505 Survey Dates: May 8, 2018 thru May 10, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Foam Extinguisher AB - composite Portable foam extinguishers

Foam Extinguisher AB - composite Portable foam extinguishers Foam Extinguisher AB - composite Portable foam extinguishers The revolution in portable fire extinguishers: composite extinguishers are durable ccorrosion resistant and low maintenance extinguishers. The

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :HS1007140060A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company :Gold Apollo Co., Ltd Address :3F.-1, No.77, Sec. 1, Xintai 5th Rd., Xizhi City, Taipei County 221, Taiwan (R.O.C.)

More information

Household and similar electrical appliances Safety

Household and similar electrical appliances Safety AS/NZS 60335.2.69:2012 (IEC 60335-2-69 Ed 4, MOD) Australian/New Zealand Standard Household and similar electrical appliances Safety Part 2.69: Particular requirements for wet and dry vacuum cleaners,

More information

Powder Extinguisher ABC - composite Portable powder extinguishers

Powder Extinguisher ABC - composite Portable powder extinguishers Powder Extinguisher ABC - composite Portable powder extinguishers The revolution in portable fire extinguishers: composite extinguishers are the latest development in the quest for durable ccorrosion resistant

More information

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 501 College Avenue Aurora, Illinois 60505 Survey Dates: May 16, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES, FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A

More information

Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD)

Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD) Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD) Title 24, Part 6 Section 120.2(i) requires that economizer FDD functions be installed on air cooled unitary air conditioning

More information

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,

More information

Working Document on a possible COMMISSION DELEGATED REGULATION

Working Document on a possible COMMISSION DELEGATED REGULATION Working Document on a possible COMMISSION DELEGATED REGULATION Implementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of vacuum cleaners EN EN Working

More information

Tuvalu. Tokelau. Samoa. Wallis and Futuna Fiji

Tuvalu. Tokelau. Samoa. Wallis and Futuna Fiji IIEC International Institute for Energy Conservation Country Report for Papua New Guinea Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon

More information

5 dock doors, 2 grade doors. Sprinklers throughout

5 dock doors, 2 grade doors. Sprinklers throughout VIEW ONLINE collierscanada.com/22011 FOR LEASE: $5.75 PSF NET FOR SALE: $5,400,000 FOR LEASE / SALE 300 Sovereign Road, London ON Excellent Manufacturing Facility with Heavy Power 56,254 SF including 8,000

More information

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment CLASSIFICATION NOTES Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment July 2016 Contents Sections 1. Scope, Application 2. Recognized Standards for Tests 3. Purpose 4. Test facilities

More information

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,

More information

LABORATORY REPORT GEOTECHNICAL / ENVIRONMEAL / MATERIALS ENGINEERS 3331 EAST WOOD STREET, PHOENIX, ARIZONA 85040 Physical Properties of Soils and Aggregates Client: Pace Pacific Corp. ATTN: Sean Moore

More information

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS Journal of GeoEngineering, Vol. 6, No. 1, pp. Chew 41-45, et al.: April Laboratory 2011 Study on the Consolidation Settlement of Clay-Filled Geotextile Tube and Bags 41 LABORATORY STUDY ON THE CONSOLIDATION

More information

CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan

CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan News Release For Immediate Release 8 August 2012 CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan Targets launch of new residential development, The

More information

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD Car DVD/Navigation Player Model No.: DT-063F, DT-0637, DT-0635, DT-0633, DT-0632, DT-0663, DT-063H, NAV-CF 8000 Prepared for : HUIZHOU FREEWAY ELECTRONIC

More information

INSPECTION REPORT Nr IDD/S-09/922

INSPECTION REPORT Nr IDD/S-09/922 Page: 1/7 PROJECT: TPI For Sheet Pile BV Client: Manufacturer: Nanjing Grand Steel Piling Co., Ltd. Inspection requested by: Ref: P/o nr: (client to BV) P/o nr: GP09111101 (client to Manufacturer) SUPPLY

More information

Electric radiator test

Electric radiator test Electric radiator test Final Report 56161/1 Carried out for Cornwall Heating Solutions Ltd & Bright Heating By Calum Maclean 27 June 2012 Electric radiator test Carried out for: Cornwall Heating Solutions

More information

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors ET Project Number: Product Manager: Sachin Andhare Pacific Gas and Electric Company` Prepared By: Danielle Geers

More information

FUNDERMAX GMBH FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT

More information

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02 Umwelt Bundes Amt For our Environment /;;;!. TÜVRheinland Precisely Right. CERTIFICATE about Product Conformity {QAL 1) Number of Certificate: 0000026912_02 Certified AMS: Manufacturer: Test Institute:

More information

IMO Resolution MSC 61(67): Annex 1: Part 2

IMO Resolution MSC 61(67): Annex 1: Part 2 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IMO Resolution MSC 61(67): Annex 1: Part

More information

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013 Product Testing Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013 On July the 13 th, 2013, the EU 665/2013 & EU 666/2013 directives were officially published on the Official

More information

The development of a plastic scintillator for radiotherapy dosimetry

The development of a plastic scintillator for radiotherapy dosimetry University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2008 The development of a plastic scintillator for radiotherapy

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12158-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2018-09-19 to 2019-09-03 Date of issue: 2018-09-19

More information

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Mike Farinacci Site: Island in the Sky (CANY-IS) Service Date(s):

More information

and Refrigerant Identifier

and Refrigerant Identifier Contaminated Refrigerant and Refrigerant Identifier What is contaminated refrigerant? Two or many type of refrigerants mixed in the cylinder or Refrigeration and air-conditioning system knowingly or unknowingly

More information

Performance Rating of Unit Ventilators

Performance Rating of Unit Ventilators AHRI Standard 840 (I-P) 1 2015 Standard for Performance Rating of Unit Ventilators Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Office Copyright 2009, by Air-Conditioning and Refrigeration Institute

More information

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product PERFORMANCE TEST REPORT Rendered to: EVERBLOCK SYSTEMS, LLC PRODUCT: Modular Block Product Report No.: G1320.01-106-31 Report Date: 08/04/16 Test Record Retention Date: 07/29/20 130 Derry Court York, PA

More information