TEST REPORT: CHM14-07-CHY
|
|
- Augustine Copeland
- 5 years ago
- Views:
Transcription
1 A TEST REPORT: CHM14-07-CHY Date: Tel: Fax: Client s Ref: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the terms set out within this report. SUBJECT Test of Naturion Ioniser NA50 for Its Performance of Clean Air Delivery Rate (PM2.5, PM10) CLIENT Serumi International Private Limited 36 Armenian Street #02-02 Singapore Attn: Mr Sean Gan PY TEST DATE 23 March 2015 DESCRIPTION OF VACCUM CLEANER The photograph and specifications of Naturion Ioniser NA50 were listed in Annex A. METHOD OF TEST The Naturion Ioniser NA50 was tested in a chamber of 200 L (Annex B); Initial particular matter concentrations were adjusted to around 400 µg/m 3 to 450 µg/m 3 for PM2.5 and PM 10; Fan was powered on during ioniser operation; The PM2.5 and PM10 concentrations were monitored under conditions with and without Naturion Ioniser NA50 operation. AHAM AC Method for Measuring Performance of Portable Household Electric Room Air Cleaners was used as a reference (Annex C). Laboratory: TÜV SÜD PSB Pte. Ltd. No.1 Science Park Drive Singapore Phone : Fax : testing@tuv-sud-psb.sg Co. Reg : R Regional Head Office: TÜV SÜD Asia Pacific Pte. Ltd. 3 Science Park Drive, #04-01/05 The Franklin, Singapore
2 RESULTS 1. PM 2.5 Removal Performance The results of PM2.5 removal performance were listed in Table 1 and plotted in Figure 1. Table 1 PM2.5 removal performance of Naturion Ioniser NA50 (unit: µg/m 3 ) Time, Minutes PM 2.5- without Naturion Ioniser NA50 Operation (Natural Decay) PM2.5- with Naturion Ioniser NA50 Operation Figure 1 Schematic diagram of PM2.5 removal performance by Naturion Ioniser NA50 Page 2 of 10
3 RESULTS (Continued) 2. PM 10 Removal Performance The results of PM10 removal performance were listed in Table 2 and plotted in Figure 2. Table 2 PM10 removal performance of Naturion Ioniser NA50 (unit: µg/m 3 ) Time, Minutes PM10- without Naturion Ioniser NA50 Operation (Natural Decay) PM10- with Naturion Ioniser NA50 Operation Figure 2 Schematic diagram of PM10 removal performance by Naturion Ioniser NA50 Page 3 of 10
4 RESULTS (Continued) 3. Calculation of Clean Air Delivery Rate (CADR) By referring to AHAM AC Method for Measuring Performance of Portable Household Electric Room Air Cleaners, the Clean Air Delivery Rate (CADR) in terms of PM2.5 and PM10 removal was calculated by: CADR = V chamber (K ioniser K natural decay ) (Annex C) Where V chamber = 200 litres K ioniser = linear regression of Ln (PM2.5/PM10- Naturion Ioniser NA50 Operation) Vs Time K natural decay = linear regression of Ln (PM2.5/PM10- Natural decay) Vs Time The CADR calculation result were listed in Table 3 and Table 4 Table 3 CADR of Naturion Ioniser NA50 in terms of PM 2.5 removal Values V chamber, litres 200 K ioniser, 1/minute (R 2 = 0.97) K natural decay, 1/minute (R 2 = 0.99) CADR (in terms of PM 2.5 removal), litres/minute CADR (in terms of PM 2.5 removal), litres/hour 2,470 Table 4 CADR of Naturion Ioniser NA50 in terms of PM 10 removal Values V chamber, litres 200 K ioniser, 1/minute (R 2 = 1.00) K natural decay, 1/minute (R 2 = 0.99) CADR (in terms of PM10 removal), litres/minute CADR (in terms of PM10 removal), litres/hour 3,611 Page 4 of 10
5 DISCUSSION The PM2.5 concentrations decreased from 418 µg/m 3 to 7 µg/m 3 in a 200 litre chamber after 15 minutes operation of Naturion Ioniser NA50 or decreased by 98.3%. The PM10 concentrations decreased from 445 µg/m 3 to 2 µg/m 3 in a 200 litre chamber after 15 minutes operation of Naturion Ioniser NA50 or decreased by 99.6%. The Clean Air Delivery Rate (CADR) of Naturion Ioniser NA50 in terms of PM2.5 removal was calculated to be litres/minute or 2,470 litres/hour. The Clean Air Delivery Rate (CADR) of Naturion Ioniser NA50 in terms of PM10 removal was calculated to be litres/minute or 3,611 litres/hour. DR. YANG LEI EXECUTIVE CONSULTANT DR CHEN HUAYI ASSISTANT VICE PRESIDENT CHEMICAL CENTRE Page 5 of 10
6 Annex A: Naturion Ioniser NA50 Specifications (Provided by Serumi International Private Limited) Name Naturion Ioniser NA50 Photograph Negative ions count Power supply Net Weight Unit dimensions Unit with clip dimensions Packaging dimensions Max pcs/cm 3 (at 100 cm distance) DC 12V 43 g mm mm mm Page 6 of 10
7 Annex B: Schematic of test chamber Particulate analyzer NA50 Wind direction Figure 3 Schematic layout of the test chamber (200 litres) Page 7 of 10
8 Annex C: CADR Calculation method (by referring to AHAM AC Section 8: Method for measuring performance of portable household electric room air cleaners) Page 8 of 10
9 Page 9 of 10
10 Please note that this Report is issued under the following terms : 1. This report applies to the sample of the specific product/equipment given at the time of its testing/calibration. The results are not used to indicate or imply that they are applicable to other similar items. In addition, such results must not be used to indicate or imply that TÜV SÜD PSB approves, recommends or endorses the manufacturer, supplier or user of such product/equipment, or that TÜV SÜD PSB in any way guarantees the later performance of the product/equipment. Unless otherwise stated in this report, no tests were conducted to determine long term effects of using the specific product/equipment. 2. The sample/s mentioned in this report is/are submitted/supplied/manufactured by the Client. TÜV SÜD PSB therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture, consignment or any information supplied. 3. Nothing in this report shall be interpreted to mean that TÜV SÜD PSB has verified or ascertained any endorsement or marks from any other testing authority or bodies that may be found on that sample. 4. This report shall not be reproduced wholly or in parts and no reference shall be made by the Client to TÜV SÜD PSB or to the report or results furnished by TÜV SÜD PSB in any advertisements or sales promotion. 5. Unless otherwise stated, the tests were carried out in TÜV SÜD PSB Pte Ltd, No.1 Science Park Drive Singapore July 2011 Page 10 of 10
TEST REPORT: CHM14-05-CHY
A TEST REPORT: 7191100863-CHM14-05-CHY Date: Tel: +65 68851291 Fax: +65 67784301 Client s Ref: Email: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations
More informationASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES
ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,
More informationJanuary 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:
January 26, 2005 Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT 06824 Dear Mr. Sunshine: We appreciate the opportunity to be of service to you. Please find enclosed one bound copy of Intertek
More informationTest Report No EEC12/08 dated 18 Jun 2012
Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is
More informationTechnical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization
Client: IZEN Co., Ltd. 242, Aegibong-ro, Wolgot-myeon Gimpo-si, Gyeonggi-do 415-873 REPUBLIC OF KOREA Contact Person: ISA AC Kim Tel.: +82-31-999-7300, 070-4705-1878 Fax.: +82-31-997-3147 Manufacturing
More informationOur Ref: CD/FSSD/12/02/03/01 DID: FAX:
Our Ref: CD/FSSD/12/02/03/01 DID: 68481407 FAX: 68481493 14 Jan 2010 Registrar, Board of Architects (BOA) Registrar, Professional Engineers Board (PEB) President, Singapore Institute of Architects (SIA)
More informationCountry Report for Solomon Islands
IIEC International Institute for Energy Conservation Country Report for Solomon Islands Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon
More informationSmartSensor 105 & Advance NEMA External Ice
SmartSensor 105 & Advance NEMA External Ice Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA external
More informationThe smart handling of liquid chemicals: quickly connected safely dispensed.
The smart handling of liquid chemicals: quickly connected safely dispensed. Now you can bid farewell to the hazards of conventional drum emptying. ESCAPING GAS! Escaping gases, vapours and particulates
More informationAugust 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:
August 3, 2010 Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2 Dear Mr. Sterio: RTI is pleased to submit this letter report to Surgically Clean Air, Inc on our project
More informationWRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7
WRc Evaluation & Testing Centre Ltd Test Code Sheet Number 1 2 1 1 17 WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October 1999 Sheet 1 of 7 TEST CODE SHEET 1. TYPE OF TEST(S) Performance
More informationTest Report. Appliance EMF Testing
Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is
More informationHPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION
Particle Sensor 550 Issue D FEATURES Laser-based light scattering particle sensing Datasheet Concentration range: 0 µg/m to,000 g/m Fully calibrated EMC: Heavy industrial level IEC6000 Response time:
More informationThe smart handling of liquid chemicals: quickly connected safely dispensed.
The smart handling of liquid chemicals: quickly connected safely dispensed. Now you can bid farewell to the hazards of conventional drum emptying. ESCAPING GAS! Escaping gases, vapours and particulates
More informationSUPPLEMENT REPORT No.: XPL/13600/
(Pty) Ltd Certex Appointed Ex Laboratory Reg No: 1999/027771/07 Government Approved Test Laboratory (Previously AIA) T0104 7 Spanner rd, PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11)
More informationCountry Report for Tonga
IIEC International Institute for Energy Conservation Country Report for Tonga Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands
More informationInstallation Instructions for the
Installation Instructions for the Particle Sensors General Information The Honeywell Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the
More informationA three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism
Object A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism 2153-16 Type TCB 145-40-31 Serial No. 16000702, 16000703
More informationMeasurement of Safety Integrity of E/E/PES according to IEC61508
Measurement of Safety Integrity of E/E/PES according to IEC61508 Mr. Chen Zhenkang TUV Rheinland Singapore 18. May. 2018 Singapore World Metrology Day 2018 1 Agenda 1. TÜV Rheinland: a Certification Body
More informationThis FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094.
This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094. They are not intended to replace the regulations nor to provide
More informationCountry Report for Kiribati
IIEC International Institute for Energy Conservation Country Report for Kiribati Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands
More informationAir Purifier Test Report (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001
PLASMA AIR INTERNATIONAL 36 Connecticut Ave Suite 13 Norwalk, CT 6954 Attn: Larry Sunshine (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 12C) Our Reference No.: Prepared by: LAWN ENVIRONMENTAL
More informationQuality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points
Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements
More informationCOA-2010-F Electronic CO 2
COA-2010-F Electronic Analyzer New electronic analyzer specifically designed to monitor and temperature for the verification of in research and pharmaceutical markets. This unit has been developed to incorporate
More informationSemiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.
Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Will Yahr Site: Big Bend NP - (BIBE-KB) Service Date(s): 7/26/217
More informationComponent Description Quantity Storage. Glass Slide 75 mm x 25 mm glass slide C. Storage Case Storage case for the glass slide C
Package Insert QuantiGene View Temperature Validation Kit Cat. No. QV0523 Product Overview The QuantiGene View Temperature Validation Kit uses a National Institute of Standards and Technology (NIST) calibrated
More informationHPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION
HPM Series Particle Sensor DESCRIPTION The Honeywell HPM Series Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the concentration range of
More informationSemiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.
Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Mike Slate Site: Canyonlands National Park (CANY-IS) Service Date(s):
More informationTEMPORARY IMMERSION AND DUST TEST REPORT
Report No. :DH1510130042A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company Address :GradConn Ltd. :No. 139 Wuhan Rd., Longtan Township, Taoyuan County, Taiwan Sample Name :Refer to see page 2
More informationSemiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.
Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Jake Zaragoza Site: Big Bend NP (BIBE-KB) Service Date(s): 2/21/217
More informationCountry Report for Niue
IIEC International Institute for Energy Conservation Country Report for Niue Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands
More informationOur Ref: SCDF/HAZ/14/03/02/01 DID: FAX: REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE
Our Ref: SCDF/HAZ/14/03/02/01 DID: 68483312 FAX: 68483318 6 th December 2011 See Distribution Dear Sir/Madam, REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE Since September 2009, a multi-agencies
More informationRotary Screw Compressors UP5 Series kw
Rotary Screw Compressors UP5 Series 11-37 kw Rotary Screw Compressors UP5 Series 11-37 kw Boost Your Profitability Boosting your company s profits was the main goal that Ingersoll-Rand had in mind when
More informationFIRE TESTING SERVICES FIRE TESTING SER
FIRE TESTING SERVICES At TUV SUD PSB, we have a fire testing laboratory that was established since the late 70 s. We provide fire tests and inspection services for various industries, both locally and
More informationWe Identify and S.T.O.P. Your Noise Problems
ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October
More informationHPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION
Particle Sensor 32322550 Issue C FEATURES Laser-based light scattering particle sensing Datasheet Concentration range: 0 µg/m 3 to 1,000 µg/m 3 Fully calibrated EMC: Heavy industrial level IEC61000 Response
More informationTest Report issued under the responsibility of:
Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen d.c. or a.c.
More informationCountry Report for Fiji
I I E C International Institute for Energy Conservation Northern Marianas Country Report for Fiji Palau Guam Federated States of Micronesia Marshall Islands Kiribati Papua New Guinea Nauru Solomon Islands
More informationENGINEERING EVALUATION
ENGINEERING EVALUATION REPORT NUMBER: 100378137MID-002 ORIGINAL ISSUE DATE: April 26 th, 2011 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett
More informationFIRESTOP INSPECTION. Dr. Selina LIN. Technical Manager August 01, FS Inspection 1
FIRESTOP INSPECTION Dr. Selina LIN Technical Manager August 01, 2017 FS Inspection 1 HILTI IN FIGURES Operations in more than 120 countries 23,385 employees (at the end of 2015) 120 nationalities in the
More informationRefrigerating Appliance ErP Test Report
Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)
More informationA Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator
A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator R. Jagan 1, R. GokulaKrishnan 2, S. Ramar 3, S. Manikandan 4, D.R.P. Rajarathnam 5 1,2,3 Student, Department
More informationAcoustic Verification Report
Acoustic Verification Report Invacare XPO 2 Portable Oxygen Concentrator Type XPO100B-EU for Date: 2013-12-10 Our reference: IS-ATC2-MUC/js Document: Report Invacare VR.600010074.002.12 - Revision 2.docx
More informationGuidelines for the Evaluation of Direct Reading Monitors
Guidelines for the Evaluation of Direct Reading Monitors ER Kennedy, ML Woebkenberg, PC Schlecht, DL Bartley, S Shulman, HA Feng, R Song NIOSH C Cowherd, Jr., MA Grelinger, and KM Bauer Midwest Research
More informationExperimental Investigation of Purification Function of Air Conditioner
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 10 Experimental Investigation of Purification Function of Air Conditioner Qi
More informationTESTS OF ADSIL COATING
TESTS OF ADSIL COATING Test B - Long Term Test FSEC-CR-1259-01 July 11, 2001 Prepared for: Bob Suggs Florida Power & Light Company 9250 W. Flagler Street Miami, Florida 33174 Principal Investigator Dr.
More informationBUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW
& e. INDUSTRIAL LOSS CONTROL & eng Analisi e Controllo dei Rischi Industriali HUGHES ASSOCIATES EUROPE, srl FIRE SCIENCE & ENGINEERING BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT
More informationTEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1
REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.
More informationTechnical-Report for SL Lamp 5 W
Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S
More informationRadon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationMETZIN Bearing Induction Heater. Operating Instructions
METZIN Bearing Induction Heater Operating Instructions Model: MIH-8.0/ S Specifications and chassis color subject to change without notice. METZIN Technologies & Consulting Pte Ltd. Tel: +65 6898 2957
More informationRadon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationGuidelines accompanying:
EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR ENERGY Directorate C - Renewables, Research and Innovation, Energy Efficiency C.3 - Energy efficiency Guidelines accompanying: Commission Delegated Regulation
More informationUVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units
UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units Part 3: Recirculation UVGI Systems, Zonal Protection Factor, In-place testing Protocols Dr. Wladyslaw Jan Kowalski, PE, Immune Building
More informationAUDITORY SYSTEMS LABORATORY HEARING PROTECTION DEVICE ATTENUATION TEST REPORT
AUDITORY SYSTEMS LABORATORY HEARING PROTECTION DEVICE ATTENUATION TEST REPORT! AUDITORY SYSTEMS LABORATORY GRADO DEPT. OF INDUSTRIAL & SYSTEMS ENGINEERING Dr. John G. Casali, Professor and Director COLLEGE
More informationReview Fire Test Report
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of
More information- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement
RN53 Radon Detector RN53 - For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement Description The RN53 Radon Detector operates on the method of electrostatic collecting of the radon
More informationLAC52 Smart Car Air Purifier
IB-00-LAC0-0 V. Designed in Finland International Limited Manufactured by Dongguan LIFAair Technology Ltd. Address: No., East Industry Road, Songshan Lake Science & Technology Industrial Park, Dongguan,
More informationClean Air Optima HEPA UV ionizer air purifier CA-508
Clean Air Optima HEPA UV ionizer air purifier CA-508 Manual Read these instructions carefully before you start using the air purifier and keep the manual for later usage. Copyright : Clean Air Optima 1
More informationCERTIFICATE of Product Conformity (QAL1)
JÄ TÜVF=heinland`:.ä;' Preci ely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000038506 02 AMs designation: lvlanufacturer: Test Laboratory: Modell 6888Afor02 Rosemount l nc. 8200
More informationRadon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,
More informationRadon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationMr. Corrado Maltese, B.Sc., C.R.S.P Senior Manager, Occupational Health and Safety Department
Toronto Catholic District School Board Catholic Education Centre 80 Sheppard Avenue East North York, Ontario M2N 6E8 Attention: Mr. Corrado Maltese, B.Sc., C.R.S.P Senior Manager, Occupational Health and
More informationInfrastructure Technology
Registered Testing Authority - CSIRO 26 June 2014 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7086.4s Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 24 June 2014 Manufacturer:
More information- Full test except clause (IPX1 IPX2) (Oxygen bomb test) and annex ต
Laboratory name Japan Electrical Testing Laboratory (Thailand) Co., Ltd. Address 46/173 Nuanchan Road, Nuanchan, Bueng Kum, Bangkok 1. A.C. electric fans - TIS 934-2533 (1990) - TIS 934-2558 (2015) 2.
More informationSTT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.
STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart
More informationRF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07
RF TEST REPORT Applicant FCC ID Brand Product ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS Model VFD 511 Multi-Mode Digital Mobile Phone Report No. RXC1703-0087RF07 Issue Date May 24,2017 TA Technology
More informationRadon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 56 Jackson Street Aurora, Illinois 60505 Survey Dates: May 8, 2018 thru May 10, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationFoam Extinguisher AB - composite Portable foam extinguishers
Foam Extinguisher AB - composite Portable foam extinguishers The revolution in portable fire extinguishers: composite extinguishers are durable ccorrosion resistant and low maintenance extinguishers. The
More informationTEMPORARY IMMERSION AND DUST TEST REPORT
Report No. :HS1007140060A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company :Gold Apollo Co., Ltd Address :3F.-1, No.77, Sec. 1, Xintai 5th Rd., Xizhi City, Taipei County 221, Taiwan (R.O.C.)
More informationHousehold and similar electrical appliances Safety
AS/NZS 60335.2.69:2012 (IEC 60335-2-69 Ed 4, MOD) Australian/New Zealand Standard Household and similar electrical appliances Safety Part 2.69: Particular requirements for wet and dry vacuum cleaners,
More informationPowder Extinguisher ABC - composite Portable powder extinguishers
Powder Extinguisher ABC - composite Portable powder extinguishers The revolution in portable fire extinguishers: composite extinguishers are the latest development in the quest for durable ccorrosion resistant
More informationRadon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 501 College Avenue Aurora, Illinois 60505 Survey Dates: May 16, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationOPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationLAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR
More informationFINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,
FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A
More informationTitle 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD)
Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD) Title 24, Part 6 Section 120.2(i) requires that economizer FDD functions be installed on air cooled unitary air conditioning
More informationASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES
ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,
More informationWorking Document on a possible COMMISSION DELEGATED REGULATION
Working Document on a possible COMMISSION DELEGATED REGULATION Implementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of vacuum cleaners EN EN Working
More informationTuvalu. Tokelau. Samoa. Wallis and Futuna Fiji
IIEC International Institute for Energy Conservation Country Report for Papua New Guinea Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon
More information5 dock doors, 2 grade doors. Sprinklers throughout
VIEW ONLINE collierscanada.com/22011 FOR LEASE: $5.75 PSF NET FOR SALE: $5,400,000 FOR LEASE / SALE 300 Sovereign Road, London ON Excellent Manufacturing Facility with Heavy Power 56,254 SF including 8,000
More informationCLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment
CLASSIFICATION NOTES Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment July 2016 Contents Sections 1. Scope, Application 2. Recognized Standards for Tests 3. Purpose 4. Test facilities
More informationASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES
ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,
More informationLABORATORY REPORT GEOTECHNICAL / ENVIRONMEAL / MATERIALS ENGINEERS 3331 EAST WOOD STREET, PHOENIX, ARIZONA 85040 Physical Properties of Soils and Aggregates Client: Pace Pacific Corp. ATTN: Sean Moore
More informationLABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS
Journal of GeoEngineering, Vol. 6, No. 1, pp. Chew 41-45, et al.: April Laboratory 2011 Study on the Consolidation Settlement of Clay-Filled Geotextile Tube and Bags 41 LABORATORY STUDY ON THE CONSOLIDATION
More informationCapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan
News Release For Immediate Release 8 August 2012 CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan Targets launch of new residential development, The
More informationEMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player
EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD Car DVD/Navigation Player Model No.: DT-063F, DT-0637, DT-0635, DT-0633, DT-0632, DT-0663, DT-063H, NAV-CF 8000 Prepared for : HUIZHOU FREEWAY ELECTRONIC
More informationINSPECTION REPORT Nr IDD/S-09/922
Page: 1/7 PROJECT: TPI For Sheet Pile BV Client: Manufacturer: Nanjing Grand Steel Piling Co., Ltd. Inspection requested by: Ref: P/o nr: (client to BV) P/o nr: GP09111101 (client to Manufacturer) SUPPLY
More informationElectric radiator test
Electric radiator test Final Report 56161/1 Carried out for Cornwall Heating Solutions Ltd & Bright Heating By Calum Maclean 27 June 2012 Electric radiator test Carried out for: Cornwall Heating Solutions
More informationCalculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors
Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors ET Project Number: Product Manager: Sachin Andhare Pacific Gas and Electric Company` Prepared By: Danielle Geers
More informationFUNDERMAX GMBH FIRE TEST REPORT
FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT
More informationCERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02
Umwelt Bundes Amt For our Environment /;;;!. TÜVRheinland Precisely Right. CERTIFICATE about Product Conformity {QAL 1) Number of Certificate: 0000026912_02 Certified AMS: Manufacturer: Test Institute:
More informationIMO Resolution MSC 61(67): Annex 1: Part 2
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IMO Resolution MSC 61(67): Annex 1: Part
More informationProduct Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013
Product Testing Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013 On July the 13 th, 2013, the EU 665/2013 & EU 666/2013 directives were officially published on the Official
More informationThe development of a plastic scintillator for radiotherapy dosimetry
University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2008 The development of a plastic scintillator for radiotherapy
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12158-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2018-09-19 to 2019-09-03 Date of issue: 2018-09-19
More informationSemiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.
Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Mike Farinacci Site: Island in the Sky (CANY-IS) Service Date(s):
More informationand Refrigerant Identifier
Contaminated Refrigerant and Refrigerant Identifier What is contaminated refrigerant? Two or many type of refrigerants mixed in the cylinder or Refrigeration and air-conditioning system knowingly or unknowingly
More informationPerformance Rating of Unit Ventilators
AHRI Standard 840 (I-P) 1 2015 Standard for Performance Rating of Unit Ventilators Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Office Copyright 2009, by Air-Conditioning and Refrigeration Institute
More informationPERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product
PERFORMANCE TEST REPORT Rendered to: EVERBLOCK SYSTEMS, LLC PRODUCT: Modular Block Product Report No.: G1320.01-106-31 Report Date: 08/04/16 Test Record Retention Date: 07/29/20 130 Derry Court York, PA
More information