Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Size: px
Start display at page:

Download "Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc."

Transcription

1 Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Mike Slate Site: Canyonlands National Park (CANY-IS) Service Date(s): 12/15/215 to 12/16/215 Site Operator: Joe Carlson Subject: Semi-Annual Maintenance All site visit and calibration forms are attached, detailing the pre- and post-maintenance calibrations and test results. SUMMARY OF FINDINGS GASEOUS POLLUTANT SUPPORT EQUIPMENT Zero-Air System (Werther / Panther Compressor PC7/4E): Maintenance - No maintenance for the pump or compressor was required at this time. The media for the zero-air system was replaced. Station Temperature: Pre-Maintenance Testing - The sensor was compared against a certified temperature transfer standard. The sensor was found to be responding within calibration acceptance criteria. GASEOUS POLLUTANT ANALYZERS Ozone Analyzer (Thermo 49c): Pre-Maintenance Testing - The ozone analyzer was compared against a Level 2 ozone transfer standard. The ozone analyzer was found to be responding within calibration acceptance criteria. Maintenance - This analyzer was removed and replaced with 49i to match the onsite transfer standard which is a 49i. Post-Maintenance Testing - The ozone analyzer was compared against a Level 2 ozone transfer standard. The ozone analyzer was found to be responding within calibration acceptance criteria. Ozone Station Reference (Thermo 49i): Pre-Maintenance Testing - The ozone station reference was compared against a Level 2 ozone transfer standard. The ozone station reference was found to be responding within calibration acceptance criteria. Maintenance - The photometer lamp intensity was increased, the tubes were cleaned, and the cooling fan filter was replaced. Post-Maintenance Testing - The ozone station reference was compared against a Level 2 ozone transfer standard. The ozone station reference was found to be responding within calibration acceptance criteria.

2 METEOROLOGICAL SENSORS Ambient Temperature and Vertical Temperature Difference (Climatronics 193): Pre-Maintenance Testing - The sensor was compared against a certified temperature transfer standard in three water baths controlled at temperatures between and 5 degrees Celsius. The sensor was confirmed to be responding within calibration acceptance criteria. Relative Humidity (Rotronic MP61): Pre-Maintenance Testing - The sensor was collocated with a certified relative humidity transfer standard. The sensor was confirmed to be responding within calibration acceptance criteria. The aspirator fan was functioning correctly. Maintenance - The sensor was replaced with a recently refurbished unit. Post-Maintenance Testing - The sensor was collocated with a certified relative humidity transfer standard. The sensor was confirmed to be responding within calibration acceptance criteria. Wind Speed (Climatronics 175): Pre-Maintenance Testing - The sensor was challenged with a certified anemometer drive. The sensor was confirmed to be responding within calibration acceptance criteria. The starting threshold test for the sensor was within acceptance criteria. The heater for the sensor was found to be functioning incorrectly. Maintenance - The sensor was replaced with a recently refurbished unit. Post-Maintenance Testing - The sensor was challenged with a certified anemometer drive. The sensor was confirmed to be responding within calibration acceptance criteria. The starting threshold test for the sensor was within acceptance criteria. The heater for the sensor was functioning correctly. Wind Direction (Climatronics 176): Pre-Maintenance Testing - The reference alignment for the sensor was checked using a compass. The reference alignment for the sensor was confirmed to be within acceptable limits. The accuracy of the sensor was tested by comparison to a reference. The sensor was confirmed to be responding within calibration acceptance criteria. The linearity of the sensor was within acceptable limits. The starting threshold test results were within acceptance criteria. The heater for the sensor was confirmed to be functioning incorrectly. Maintenance - The sensor was replaced with a recently refurbished unit. Post-Maintenance Testing - The reference alignment for the sensor was checked using a compass. The reference alignment for the sensor was confirmed to be within acceptable limits. The accuracy of the sensor was tested by comparison to a reference. The sensor was confirmed to be responding within calibration acceptance criteria. The linearity of the sensor was within acceptable limits. The starting threshold test for the sensor was within acceptance criteria. The heater for the sensor was functioning correctly. Solar Radiation (Li-Cor Pyranometer): Pre-Maintenance Testing - The sensor was collocated with a certified solar radiation transfer standard. The sensor was confirmed to be responding within calibration acceptance criteria. The sensor was found to be level and clean. Maintenance - No maintenance was required.

3 Post-Maintenance Testing - The sensor was collocated with a certified solar radiation transfer standard. The sensor was confirmed to be responding within calibration acceptance criteria. Precipitation (Climatronics 158): Pre-Maintenance Testing - The sensor was challenged using a known volume of water. The sensor was found responding within calibration acceptance criteria. The sensor was found to be level and clean. The heater was found to be functional. PARTICULATE MONITORS AND SAMPLERS CASTNET Filter Pack Flow: Pre-Maintenance Testing - A leak check on the system was performed and results were within acceptable limits. The flow was checked using a certified flow standard measuring flow in standard conditions. The measured flow was found to be within calibration acceptance criteria. Maintenance - The pump was rebuilt, the fittings were cleaned, and the inline filter was replaced. Post-Maintenance Testing - The flow was checked using a certified flow standard measuring flow in standard conditions. The measured flow was confirmed to be within calibration acceptance criteria. ADDITIONAL COMMENTS The shelter is showing its age. This shelter is an old custom wooden shelter. A park electrician recently added some additional outlets to minimize and electrical safety issues in the shelter.

4 SITE INFORMATION ABBR. CANY SITE NAME NETWORK TYPE CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 Boneyard DATE OF LAST VISIT 6/8/215 NPS LATITUDE LONGITUDE North West Deg Min Sec --CALCULATE-> Decimal Decimal CALCULATE-> Deg Min Sec ELEVATION Meters --CALCULATE-> Feet Feet CALCULATE-> Meters 1789 DAY TIME IN TIME OUT 12/15/ /16/ SITE STANDARDS PM Flow Reference Please verify site standards used by the site operator MANUFACTURER MODEL SERIAL # NA Calibration Expiration Date NOTES:

5 TEMPERATURE / VERTICAL TEMPERATURE DIFFERENCE SYSTEM VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS MANUFACTURER MODEL SERIAL NUMBER EXPIRATION DATE Temperature Reference Eutechnics /23/216 Serial Number Climatronics List sensors according to height on tower, from highest to lowest. Serial Number Temp. Deltas CALIBRATION ACCEPTANCE CRITERIA (<=) Ambient Temperature Difference ( o C).2 Vertical Temperature Difference ( o C).1 Bath Temp ( o C) MAX ABS Difference.22 MAX ABS Difference Yes No N/A Yes No N/A Yes No N/A Yes No N/A Each sensor was verified against its data channel? Yes No N/A Each Temperature Difference = Upper - Lower? Yes No N/A Bath Temp ( o C) MAX ABS Difference MAX ABS Difference NOTES:

6 STATION TEMPERATURE SENSOR VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE SITE NAME Boneyard DATE OF LAST VISIT Network type NPS 12/15/215 6/8/215 Temperature Reference MANUFACTURER Eutechnics MODEL SERIAL NUMBER EXPIRATION DATE 2/23/216 CALIBRATION ACCEPTANCE CRITERIA (<=) Temperature Difference ( o C) 2. Temperature Reference ( o C) DAS ( o C) Difference Reference ( o C) DAS ( o C) Temperature Difference NOTES:

7 RELATIVE HUMIDITY SENSOR VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE SITE NAME Boneyard DATE OF LAST VISIT Network type NPS 12/15/215 6/8/215 RH SENSOR REFERENCE MANUFACTURER Rotronic MODEL Hygroclip SERIAL NUMBER EXPIRATION DATE 7/13/216 Serial Number Rotronic MP61A 5264 Serial Number Rotronic MP61A 526 FIELD CALIBRATION ACCEPT. CRITERIA (<=) Relative Humidity Difference (%) 5% Hour Relative Humidity (%) Relative Humidity (%) STD DAS Difference V Hour STD DAS Difference 7.1% 65.9% -4.2% % 57.1% 4.6% 66.9% 65.4% -1.5% % 58.4% 5.% 66.5% 66.2% -.3% 68.4% 68.1% -.3% V Average -1.6% Average 4.8% Aspirator fan functional? Yes No N/A NOTES: RH replaced at 93 logger time on 12/16/15.

8 WIND SPEED SENSOR VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS MANUFACTURER MODEL SERIAL NUMBER EXPIRATION DATE Wind Speed Reference RM Young 1882 CA 387 2/26/216 Wind Speed Torque Gauge RM Young 1831 NA and Climatronics / and Climatronics / Heavy Duty Aluminum Heavy Duty Aluminum Sensor Serial # 152 Sensor Serial # 1478 / NPS 985 Cups Serial # 1144 Cups Serial # 1144 CALIBRATION ACCEPTANCE CRITERIA (<=) Wind Speed Difference (m/s) Wind Speed Difference (%).2 5.% if wind speed <= 5 m/s if wind speed > 2 m/s Wind Speed Threshold (m/s vs % Diff.) Select UNITS m/s Motor Speed (rpm) Target Speed Wind Speed DAS Difference.23 N/A N/A N/A % % % % % Starting Threshold Torque <=.3 g-cm TORQUE.1 NO ACTION REQUIRED Heater sleeve functional? Yes No N/A Wind Speed Motor Speed (rpm) Target Speed DAS Difference..25 N/A N/A N/A % % % % % Starting Threshold Torque <=.3 g-cm TORQUE.1 NO ACTION REQUIRED NOTES: Heaters were not plugged in upon arrival.

9 WIND DIRECTION SENSOR VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS Direction Alignment Reference Direction Linearity Reference Direction Torque Gauge MANUFACTURER MODEL SERIAL NUMBER Brunton 56LM RM Young NA RM Young NA EXPIRATION DATE & Sensor Serial # Vane Serial # Climatronics & Climatronics / NPS 9833 Sensor Serial # 2228 / NPS Vane Serial # 351 Local Magnetic Declination (degrees) 1.5 Method Sun Azimuth CALIBRATION ACCEPTANCE CRITERIA (<=) Cross-arm Alignment Error (degrees) N/A Total Align. Diff (degrees) 5 Sensor Linearity (degrees) 3 Mag. Dec. from NOAA (deg/min/sec) Landmarks Degrees From the North From the South 18 From the East 9 From the West 27 Is the Reference Alignment intended to be N-S? YES Is the Reference Alignment intended to be N-S? YES Reference Alignment (degrees). Reference Alignment (degrees). SENSOR ALIGNMENT N-S Reference Degrees DAS From the North 359. From the South From the East From the West Total Alignment MAX ABS Diff OR SENSOR ALIGNMENT Landmark Degrees DAS Difference Landmark Degrees DAS Difference OR Difference SENSOR ALIGNMENT N-S Reference Degrees DAS From the North From the South From the East From the West Total Alignment MAX ABS Diff SENSOR ALIGNMENT SENSOR ALIGNMENT X Reference Degrees DAS Difference X Reference Degrees DAS Align with Ref (N) 18 Align with Ref (S) 18 9 Perp with Ref (E) 9 27 Perp with Ref (W) 27 Total Alignment MAX ABS Diff Total Alignment MAX ABS Diff OR SENSOR ALIGNMENT From the North From the North From the South 18 From the South 18 From the East 9 From the East 9 From the West 27 From the West 27 Total Alignment MAX ABS Diff Total Alignment MAX ABS Diff OR Difference Difference SENSOR LINEARITY Point DAS MAX Difference Difference N/A SENSOR LINEARITY Point DAS Difference N/A MAX Difference 2 NO ACTION REQUIRED NO ACTION REQUIRED Starting Threshold TORQUE Starting Threshold Torque <= 6. g-cm 5. Torque <= 6. g-cm NO ACTION REQUIRED TORQUE 5. NO ACTION REQUIRED Heater sleeve functional? Yes No N/A NOTES:

10 SOLAR RADIATION SENSOR VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT Network type NPS 6/8/215 Solar Radiation Reference MANUFACTURER MODEL SERIAL NUMBER EXPIRATION DATE LICOR Li-2 PY /19/216 MULTIPLIER Serial Number Translator Logger Type ESC Climatonics PY High Input (V) 5. Low Input (V). High Output Low Output. Climatonics Serial Number PY Translator 65 Logger Type High Input (V) 5. ESC Low Input (V). High Output Low Output. CALIBRATION ACCEPTANCE CRITERIA (<=) Difference from CTS (%) 5% Solar Radiation Hour CTS (W/m 2 ) DAS (W/m 2 ) Difference % % % V DARK RESPONSE DAS (W/m 2 ) 1 MEAN ABS % DIFF 4.4% Sensor found clean? Yes No Sensor found level? Yes No Solar Radiation Hour CTS (W/m 2 ) DAS (W/m 2 ) Difference % % % % % MEAN ABS % DIFF 2.8% V DAS (W/m 2 ) DARK RESPONSE 1 NOTES:

11 PRECIPITATION SENSOR VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS MANUFACTURER MODEL SERIAL NUMBER Precipitation Reference Novalynx drip bottle NA EXPIRATION DATE Serial Number Climatonics 158 NPS 987 Serial Number Climatonics 158 CALIBRATION ACCEPTANCE CRITERIA (<=) Difference from Input Volume (%) 5% X Reference Chart Input Volume (ml) Climatronics Climatronics Met One G-H Diameter (in.) mm/tip ml/tip Met One RM Young Texas Electronics TR-525I-HT DAS target Conversions Value Units Value 1. inch mm 1. Units mm inch Reference (ml) Target (mm) Precipitation DAS (mm) Difference % Heater functional? Yes No N/A Sensor found level? Yes No Sensor found clean? Yes No Precipitation Reference (ml) Target (mm) DAS (mm) Difference 946 NOTES:

12 CASTNET FLOW SYSTEM VERIFICATION & CALIBRATION ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS MFC High Flow Reference MANUFACTURER MODEL SERIAL NUMBER BIOS Definer EXPIRATION DATE 1/19/216 MFC Serial Number Tylan FC-28 AW94322 MFC Serial Number Tylan FC-28 AW94322 Pump Thomas 17CAB18A Serial Number Flow Target 3. ENTER FLOWS IN SLPM Pump Thomas 17CAB18A Serial Number MFC Display Linear Regression Date Setpoint Slope Intercept 6/8/ MFC VDC Linear Regression Setpoint 2.8 Slope 1.84 Intercept -.7 ESC Logger Scaling High Input (V) Low Input (V) High Output (LPM) Low Output (LPM) Operational Checks Vacuum DAS Flow MFC Flow Flow Standard Target Flow Standard Rotometer MFC Display MFC Volts DC DAS Display Difference Value % Pump Off. SLPM Leak Test. SLPM SLPM % 2 (low) 2.5 SLPM % 3 (target) 3. SLPM % 4 (high) 3.5 SLPM % 5 4. SLPM % MAX > 4. SLPM % Leak Test Results Flow (SLPM).2 *Note: A leak is present if the difference between the zero and leak test value is greater than.1 lpm Recalibration Not Required *Note: A calibration is required if the difference between the transfer standard and the DAS value is greater than +/- 2.% at the target setting or greater than +/- 2.5% at either the low or high point NEW CALIBRATION FACTORS MFC Display Linear MFC VDC Linear Regression Regression ESC Logger Scaling Setpoint Setpoint High Input (V) 5. Slope Slope 1.96 Low Input (V). Intercept -.51 Intercept -.29 High Output (LPM) Correlation.999 Correlation.999 Low Output (LPM) -.29 Target Flow Standard Rotometer MFC Display MFC Volts DC DAS Display Value % Pump Off. SLPM Leak Test. SLPM SLPM % 2 (low) 2.5 SLPM % 3 (target) 3. SLPM % 4 (high) 3.5 SLPM % 5 4. SLPM % MAX > 4. SLPM % Leak Test Results Flow (SLPM) -.1 *Note: A leak is present if the difference between the zero and leak test value is greater than.1 lpm Operational Checks Vacuum -19. DAS Flow 3. MFC Flow 2.8 Flow Standard 3. NOTES: Rebuilt pump, cleaned fittings, adjusted scaling, replaced filter. Difference

13 OZONE ANALYZER VERIFICATION & CALIBRATION () ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS Logger Slope Correction.9928 Logger Intercept Correction.1382 TRANSFER STANDARD AMBIENT ANALYZER STATION REFERENCE Thermo Thermo Thermo 49i 49C 49i DATA ACCEPTANCE CRITERIA (<=) Serial Number Serial Number Serial Number Mean Absolute Difference (%) 1% Coefficient 1. Coefficient 1.28 Coefficient 1. Maximum Absolute Difference (%) 1% Background. Background -2.7 Background. Linearity % of Fullscale 2% Cell A Intensity (Hz) 1264 Cell A Intensity (Hz) Cell B Intensity (Hz) Cell B Intensity (Hz) Cell B Intensity (Hz) 8256 Flow A (lpm).64 Flow A (lpm).623 Flow A (lpm).671 Flow B (lpm).64 Flow B (lpm).687 Flow B (lpm).664 Pressure (mmhg) 69.5 Pressure (mmhg) 62.5 Pressure (mmhg) CALIBRATION ACCEPTANCE CRITERIA (<=) Mean Absolute Difference (%) 3% Maximum Absolute Difference (%) 3% Linearity % of Fullscale 1% Cell A Intensity (Hz) SLOPE INT Transfer Standard Correction Factors Full Scale (ppb) 25 Linear Regression Plot Bench Temp ( C) 27.9 Bench Temp ( C) 34.3 Bench Temp ( C) 31.6 Bench Lamp Temp ( C) 53.8 Bench Lamp Temp ( C) 56.4 Bench Lamp Temp ( C) 53.9 Ozone Lamp Temp ( C) 68.8 Ozone Lamp Temp ( C) 71 Ozone Lamp Temp ( C) NA Ozone Source Yes Ozone Source No Transfer Standard Level LEVEL 2 Transfer Standard Level LEVEL 3 Analyzer DAS (ppb) ZERO % % % %.2% % %.3% %.3% ZERO N/A.% N/A.1% Analog Test Analyzer DAS Zero Full Scale Line Loss Test Span (site tubing) % Analyzer Display Span (bypass tubing) 2 O3 LAMP TRANSFER STANDARD AMBIENT ANALYZER STATION REFERENCE POINT TARGET % or mv Display Corrected DAS Reference DAS % P/F -1.3% Diff %Diff Linearity % DAS Diff %Diff % -.1% % % N/A -.3% -.1% 15.5.%..7 N/A % 1.4%.1%.8%.2% Mean ABS % Diff 2.2% Mean ABS % Diff 1.2% Y-Intercept.36 Y-Intercept -.18 Correlation 1. Correlation 1. Linearity % -.4%.% 3. 2.% -.3% Max ABS % Difference 2.6% Max ABS % Difference 2.% Slope 1.21 Slope y = 1.216x Transfer Standard (ppb) R² =.9999 Residuals Plot 15 1 Residual (ppb) Regression Concentration Value (ppb) NOTES:

14 OZONE ANALYZER VERIFICATION & CALIBRATION () ABBR. CANY CLIENT NPS FIELD SPECIALIST M. Slate DATE 12/15/215 SITE NAME Boneyard DATE OF LAST VISIT 6/8/215 Network type NPS Logger Slope Correction.9966 Logger Intercept Correction.1848 CALIBRATION ACCEPTANCE CRITERIA (<=) TRANSFER STANDARD AMBIENT ANALYZER STATION REFERENCE Mean Absolute Difference (%) 3% Thermo Thermo Thermo Maximum Absolute Difference (%) 3% Linearity % of Fullscale 1% 49i 49i 49i DATA ACCEPTANCE CRITERIA (<=) Serial Number Serial Number Serial Number Mean Absolute Difference (%) 1% Coefficient 1. Coefficient 1.16 Coefficient 1. Maximum Absolute Difference (%) 1% Background. Background -.2 Background. Linearity % of Fullscale 2% Cell A Intensity (Hz) Cell A Intensity (Hz) 9193 Cell A Intensity (Hz) Cell B Intensity (Hz) Cell B Intensity (Hz) Cell B Intensity (Hz) 1268 Transfer Standard Correction Factors 1.53 Flow A (lpm).638 Flow A (lpm).77 Flow A (lpm).667 Flow B (lpm).639 Flow B (lpm).72 Flow B (lpm).664 Full Scale (ppb) 25 Pressure (mmhg) 69.2 Pressure (mmhg) Pressure (mmhg) Linear Regression Plot Bench Temp ( C) 32.3 Bench Temp ( C) 29.3 Bench Temp ( C) 33.5 Bench Lamp Temp ( C) 53.8 Bench Lamp Temp ( C) 53.8 Bench Lamp Temp ( C) 53.9 Ozone Lamp Temp ( C) 68.6 Ozone Lamp Temp ( C) 67.2 Ozone Lamp Temp ( C) NA Ozone Source Yes Ozone Source No Transfer Standard Level LEVEL 2 Transfer Standard Level LEVEL 3 POINT TARGET O3 LAMP TRANSFER STANDARD AMBIENT ANALYZER STATION REFERENCE % or mv Display Corrected DAS Diff %Diff Linearity % DAS Diff %Diff Linearity % ZERO N/A -.3%.3.1 N/A -.1% % %.% %.2% % %.1% %.% % % -.4% % -.4% % % -.1% %.1% % %.3% %.% ZERO N/A.3% N/A.3% Mean ABS % Diff.6% Mean ABS % Diff.8% Max ABS % Difference 1.9% Max ABS % Difference 1.7% Analog Test Analyzer DAS Reference DAS Slope 1.6 Slope 1.1 Zero -.6 Full Scale Y-Intercept -.8 Y-Intercept -.29 Correlation 1. Correlation Residuals Plot Residual (ppb) Analyzer DAS (ppb) SLOPE INT y =.8655x Transfer Standard (ppb) R² = Regression Concentration Value (ppb) NOTES: Replaced analyzer with a 49i. Increased lamp setting in 3rd level. Cleaned tubes. Cleaned fan filters.

15 CALIBRATION AND VERIFICATION STANDARDS ABBR. CANY SITE NAME Network type CLIENT NPS Boneyard NPS FIELD SPECIALIST M. Slate DATE DATE OF LAST VISIT 12/15/215 6/8/215 MANUFACTURER MODEL SERIAL # Calibration Expiration Date Ozone Transfer Standard Thermo 49i /26/216 MFC High Flow Reference BIOS Definer /19/216 MFC Low Flow Reference Temperature Reference Eutechnics /23/216 AT/RH Sensor Reference Rotronic Hygroclip /13/216 Barometric Pressure Reference Wind Speed Reference (high rpm) RM Young 1882 CA 387 2/26/216 Wind Speed Reference (low rpm) Wind Speed Torque Gauge RM Young 1831 NA Wind Direction Alignment Reference Brunton 56LM Wind Direction Linearity Reference RM Young NA Wind Direction Torque Gauge RM Young NA Solar Radiation Reference Multiplier W/m2 / mv LICOR Li-2 PY /19/216 UV Radiation Reference Multiplier W/m2 / mv Precipitation Reference Volume 946 ml Novalynx drip bottle NA Voltage Measurement Reference Voltage Source PM Flow Standard #1 PM Flow Standard #2 PM Flow Standard #3 PM Flow Standard #4 PM Temperature Standard #1 PM Temperature Standard #2 PM Temperature Standard #3 PM Temperature Standard #4 PM Barometric Pressure Standard #1 PM Barometric Pressure Standard #2 PM Barometric Pressure Standard #3 PM Barometric Pressure Standard #4 TEOM MTV Standard

16 REPORT OF VERIFICATION U. S. Environmental Protection Agency Office of Research and Development Air Pollution Prevention and Control Division Technical Services Branch 19 T.W. Alexander Drive RTP, NC Primary Standard Guest Information U.S. EPA Agency: EPA RTP Agency: Air Resource Specialists Scott Moore Contact: Scott Moore Contact: Christian Kirk 493 Old Page Rd. Make: NIST Make: Thermo Scientific RTP, NC 2779 : SRP : 49i (919) S/N: 1 S/N: moore.scott@epa.gov NIST Ver. May 8, 215 Offset: Level 2 Status: m %RSD.17% Slope Intercept R 2 b STDEV.7 Averages: Upper Limit: NA Lower Limit NA Date Time Date Time Start Start End End File Slope Intercept R 2 1/16/15 21:31 1/17/15 :16 c1161.xls DAY 1 1/17/15 :16 1/17/15 3:4 c1162.xls DAY 2 1/17/15 3:4 1/17/15 5:55 c1163.xls DAY 2 1/17/15 5:55 1/17/15 8:4 c1164.xls DAY 2 1/17/15 8:41 1/17/15 11:26 c1165.xls DAY 2 1/17/15 11:26 1/17/15 14:25 c1166.xls DAY 2 1/17/15 14:25 1/17/15 17:24 c1167.xls DAY 2 1/17/15 17:24 1/17/15 2:13 c1168.xls DAY 2 1/17/15 2:13 1/17/15 23:3 c1169.xls DAY 2 1/17/15 23:4 1/18/15 1:58 c1161.xls DAY 2 1/18/15 1:58 1/18/15 4:57 c11611.xls DAY 3 1/18/15 4:57 1/18/15 7:45 c11612.xls DAY 3 1/18/15 7:46 1/18/15 1:38 c11613.xls DAY 3 1/18/15 1:38 1/18/15 13:35 c11614.xls DAY 3 1/18/15 13:35 1/18/15 16:29 c11615.xls DAY 3 1/18/15 16:29 1/18/15 19:22 c11616.xls DAY 3 1/18/15 19:22 1/18/15 22:1 c11617.xls DAY 3 1/18/15 22:1 1/19/15 1:2 c11618.xls DAY 3 1/19/15 1:2 1/19/15 3:52 c11619.xls DAY 4 1/19/15 3:52 1/19/15 6:46 c1162.xls DAY 4 1/19/15 6:46 1/19/15 9:39 c11621.xls DAY 4 1/19/15 9:39 1/19/15 12:27 c11622.xls DAY 4 1/19/15 12:27 1/19/15 15:2 c11623.xls DAY 4 1/19/15 15:21 1/19/15 18:9 c11624.xls DAY 4 1/19/15 18:9 1/19/15 2:57 c11625.xls DAY 4 1/19/15 2:58 1/19/15 23:45 c11626.xls DAY 4 1/19/15 23:46 1/2/15 2:4 c11627.xls DAY 4 1/2/15 2:4 1/2/15 5:28 c11628.xls DAY 5 1/2/15 5:28 1/2/15 8:16 c11629.xls DAY 5 1/2/15 8:16 1/2/15 11:5 c1163.xls DAY 5 1/2/15 14:55 1/2/15 17:41 c121.xls DAY 5 1/2/15 17:41 1/2/15 2:34 c122.xls DAY 5 1/2/15 2:34 1/2/15 23:24 c123.xls DAY 5 1/2/15 23:24 1/21/15 2:17 c124.xls DAY 5

17 1/21/15 2:17 1/21/15 5:13 c125.xls DAY 6 1/21/15 5:13 1/21/15 8:5 c126.xls DAY 6 1/21/15 8:5 1/21/15 1:58 c127.xls DAY 6 1/21/15 1:58 1/21/15 13:46 c128.xls DAY 6 1/21/15 13:46 1/21/15 16:36 c129.xls DAY 6 1/21/15 16:36 1/21/15 19:28 c121.xls DAY 6 1/21/15 19:28 1/21/15 22:16 c1211.xls DAY 6 1/21/15 22:16 1/22/15 1:6 c1212.xls DAY 6 1/22/15 1:6 1/22/15 3:55 c1213.xls DAY 7 1/22/15 3:55 1/22/15 6:55 c1214.xls DAY 7 1/22/15 6:55 1/22/15 9:49 c1215.xls DAY 7 Comments: The verification was run for 7 days due to an extended holiday weekend. A total of 45 complete cycles were run, whereas only six (one per day) are required. The Ozone Concentrations were run, on an average, at 959, 883, 89, 735, 663, 59, 515, 438, 364, 31, 231, 152, 74 and 22 ppb with a Zero at the start and at the end of each cycle. The instrument Slope was set at Y = 1.X +. and was not altered. The %RSD of all the Slopes should not exceed 3.7% and the Standard Deviation for all the Intercepts should be less than 1.5. (Transfer Standard for Calibration of Air Monitoring Analyzers for Ozone Technical Assistance Document, October 213, see Table 3 1) The next Re Verification will be due by 1/22/16. Scott A. Moore DATE: January 26, 215

18

19

20

21

22

23

24

25

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Jake Zaragoza Site: Big Bend NP (BIBE-KB) Service Date(s): 2/21/217

More information

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Will Yahr Site: Big Bend NP - (BIBE-KB) Service Date(s): 7/26/217

More information

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc. Client: National Park Service Field Personnel: Mike Farinacci Site: Island in the Sky (CANY-IS) Service Date(s):

More information

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to

More information

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF 2015 SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF FINAL APPROVAL REVISION #: 0 ISSUE DATE: December 4, 2015 PAGE: 1 of 13 This Methods

More information

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST AHRI CERTIFICATION PROGRAM FOR AIR-COOLED WATER-CHILLING PACKAGES USING THE VAPOR COMPRESSION CYCLE ACCL Participant: Date of Test: Witness Test

More information

CMT MANUAL 6. NMC SENSORS

CMT MANUAL 6. NMC SENSORS CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7

More information

Air Resource Specialists, Inc.

Air Resource Specialists, Inc. Air Resource Specialists, Inc. Optec NGN-2A Nephelometer Support Systems Price List July 2006 FULLY INTEGRATED OPTEC NGN-2A MONITORING AND DATA LOGGING SUPPORT SYSTEMS (costs do not include the Optec NGN-2A

More information

MP 601A Humidity Probe INSTRUCTION MANUAL

MP 601A Humidity Probe INSTRUCTION MANUAL MP 601A Humidity Probe INSTRUCTION MANUAL CONTENTS DESCRIPTION... 3 OPERATION... 3 WIRING... 5 INSTALLATION... 7 MAINTENANCE...7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 9 SPECIFICATIONS... 11

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTICAL DATA REDUCTION AND VALIDATION (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTICAL DATA REDUCTION AND VALIDATION (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES TITLE OPTICAL DATA REDUCTION AND VALIDATION (IMPROVE PROTOCOL) TYPE STANDARD OPERATING PROCEDURE NUMBER 4400 DATE NOVEMBER 2004 AUTHORIZATIONS TITLE

More information

Smoke Particulate Monitors: 2006 Update

Smoke Particulate Monitors: 2006 Update United States Department of Agriculture Forest Service Technology & Development Program Smoke Particulate Monitors: 2006 Update 2500 Watershed, Soil, and Air December 2006 0625 2842 MTDC Smoke Particulate

More information

Integrating Nephelometer - Visibility and Particulate Monitoring. Summary

Integrating Nephelometer - Visibility and Particulate Monitoring. Summary Summary This paper investigate the correlation between the Aurora 1000 integrating Nephelometer single wavelength green source 525 nm and the Thermo Fisher 1400A/B TEOM, Met-One 1020 BAM, and FRM sampler.

More information

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B For Vantage Pro and Vantage Pro Plus The Vantage Pro Integrated Sensor Suite (ISS) with the Fan-Aspirated Radiation Shield

More information

Audit/Twinning Report

Audit/Twinning Report Audit/Twinning Report Station name: Danum Valley Date: November 26 302017 Auditor: Dr. Thomas Tuch (WMO GAW WCCAP, TROPOS) Responsible station staff: Maznorizan Bt Mohamad, Mohan Kumar A/L Sammathuria

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

HOBO U30 Remote Monitoring Systems

HOBO U30 Remote Monitoring Systems onset HOBO U30 Remote Monitoring Systems Web-based environmental monitoring All electronics housed within a research-grade, tamperproof enclosure Setup is quick and easy with plug-and-play sensors GSM

More information

Three categories of instruments

Three categories of instruments Instrument Descriptions Part 2 of 2 Three categories of instruments are discussed in this report: optical real-time, continuous particulate monitors, mass quantifying real-time continuous particulate monitors,

More information

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications LI-830 and LI-850 Gas Analyzers For Continuous Monitoring Applications Easy Operation The LI-830 CO2 and LI-850 CO2/H2O Analyzers are high-performance monitoring solutions that give accurate, stable readings.

More information

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications LI-830 and LI-850 Gas Analyzers For Continuous Monitoring Applications Easy Operation The LI-830 CO2 and LI-850 CO2/H2O Analyzers are high-performance monitoring solutions that give accurate, stable readings.

More information

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

SENTRY-MS Mono-static Multi-gas Open Path Analyzer SENTRY-MS Mono-static Multi-gas Open Path Analyzer Air Monitoring Where You Need it... The Cerex Sentry-MS Multi-gas Open Path Analyzer is specifically designed for rapid deployment for a variety of indoor

More information

LIQUIDATOR Electronic Ionization System

LIQUIDATOR Electronic Ionization System LIQUIDATOR Electronic Ionization System Operation and Installation Manual LIQUITECH LIQUIDATOR Series Electronic Controller Unit LIQUITECH Model QLTF Flow Cell LiquiTech, Inc. 421 Eisenhower Lane South

More information

Model 1062 Environment Monitor

Model 1062 Environment Monitor Model 1062 Environment Monitor Continuously Monitors Environment Temperature Humidity Barometric Pressure Line Voltage Line Frequency Applications Manufacturing The 1062A Environment Monitor will ensure

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:

More information

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point

More information

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES AUTHORIZATIONS TITLE NAME SIGNATURE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES AUTHORIZATIONS TITLE NAME SIGNATURE QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES TITLE SITE SELECTION FOR OPTICAL MONITORING EQUIPMENT (IMPROVE PROTOCOL) TYPE STANDARD OPERATING PROCEDURE NUMBER 4050 DATE FEBRUARY 1994 AUTHORIZATIONS

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES TITLE OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) TYPE STANDARD OPERATING PROCEDURE NUMBER 4700 DATE JANUARY 1995 AUTHORIZATIONS

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca. Monitoring Parameter: Methane and Non-Methane Hydrocarbons Revision No: Draft Revision Date: 09 April, 2018 Title: Standard Operating Procedure for the Non-Continuous Measurement of Ambient Methane and

More information

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION...3 OPERATION...3 INSTALLATION (Tips for fixed probe installation)...4 MAINTENANCE...6 CALIBRATION...6 SPECIFICATIONS...8 PLEASE,

More information

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support. AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution

More information

ST Wiring diagram. Product description. Four-stage controller. Order number

ST Wiring diagram. Product description. Four-stage controller. Order number ST96-35.16 Four-stage controller Order number 99.2 Wiring diagram Product description The four-stage controller with 4-digit setpoint and actual value display, 3 keys and 4 relays was developed for the

More information

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9. Humidity sensors Behavior in different environments Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.29 CZECH TECHNICAL UNIVERSITY IN PRAGUE CERN Content Content...

More information

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer Model 6650SP Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer 6650SP - OVERVIEW The Model 6650SP is the next generation in-water Analyzer. The 6650SP incorporates the most advanced, state-of-the-art

More information

Understanding total measurement uncertainty in power meters and detectors

Understanding total measurement uncertainty in power meters and detectors Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and

More information

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 SAE Alternate Refrigerant Cooperative Research Program Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 To: Alternate Refrigerant Task Force Members From: Ward Atkinson

More information

Standard SPECIFICATIONS FEATURES APPLICATIONS

Standard SPECIFICATIONS FEATURES APPLICATIONS SPECIFICATIONS PC Board Mountable Pressure Sensor 0-50 mv Output Voltage Excitation Gage, Absolute, and Differential Temperature Compensated FEATURES Dual-in-Line Package 0ºC to 50ºC Compensated Temperature

More information

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost SPECIFICATIONS PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost The MS1471 is a piezoresistive silicon pressure sensor packaged in a surface mount configuration. It is intended

More information

UV Sentry. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific Fugitive Emissions Quantification

UV Sentry. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific Fugitive Emissions Quantification UV Sentry Open Path Multi-gas UVDOAS Analyzer Ammonia Benzene Carbon Disulfide Chlorine Cost Effective Perimeter & LDAR Monitoring The UV Sentry offers perimeter monitoring with among the lowest cost per

More information

2-wire Passive Intelligent Loop (LED) Display Meter

2-wire Passive Intelligent Loop (LED) Display Meter Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter

More information

Ammonia Leak Detector Manual

Ammonia Leak Detector Manual Ammonia Leak Detector Manual Document No. 70-PHW-1023-R2.5 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,

More information

SimpleVIS Viscometer Reference Guide P

SimpleVIS Viscometer Reference Guide P SimpleVIS Viscometer Reference Guide P82.0090 Run Status Indicator Lamps Sample/Solvent Port Waste Bottle Dust Cover Temperature Calibration Port Touch Screen Display RS-232 Serial Port Exhaust Muffler

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD. metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD. Product brocure 1 is reliable, fast and easiest to use tool designed for routine

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

300/400 UNITS - MODULAR CONFIGURATION

300/400 UNITS - MODULAR CONFIGURATION 300/400 UNITS - MODULAR CONFIGURATION 300/400 UNITS - MODULAR CONFIGURATION TRITIUM MONITORS ESSENTIAL CHARACTERISTICS, FEATURES AND OPTIONS These are line powered tritium monitors for continuous unattended

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

Heating controller with optimisation functions

Heating controller with optimisation functions TAC 2112 C-10-42 Heating controller with optimisation functions 1999.12 The TAC 2112 offers for control of hot water systems. The radiator circuit is controlled according to an outdoor -compensated reset

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors ET Project Number: Product Manager: Sachin Andhare Pacific Gas and Electric Company` Prepared By: Danielle Geers

More information

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses SELECTION GUIDE SELECTION GUIDE Pressure, Flow & Liquid Level Products for Aerospace & Military Uses P R E C I S I O N S E N S O R S Altitude Switches PRECISION SENSORS 50 Seemans Lane Milford, CT 06460

More information

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...

More information

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight Features Representative photograph, actual product appearance may

More information

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 PRODUCT DATA FEATURES Solid or split core loop-powered current transmitters Fast response time Integral DIN rail mounting flange

More information

OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM

OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM Design & Engineering Services OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison December 2012 Acknowledgements

More information

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11 Table of Contents INTRODUCTION 1 THEORY OR OPERATION 2 DESCRIPTION 5 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 SPECIFICATIONS 10 OPTIONS

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 96 Project No. G85 Date: April 6, 5 REPORT NO. 85LAX- TEST OF ONE WALL BRACKET JELLY JAR MODEL NO. H-CGU--B LED MODEL NO. BRIDGELUX BXRC-E-C-X DRIVER MODEL

More information

10. Water Dispensers

10. Water Dispensers 0. Water Dispensers 402. General features 404. 44. stainless steal 4. Accessories 422. Sanitation Cooler clean 423. Ozone disinfection 42. Sanitizing protocol 42. Filters guide 400 40 General features

More information

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual Automatic Humidity Controller Model 512 (Revision C) Operating Manual 6/5/03 1 TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 GENERAL DESCRIPTION 3 3 2.1 Humidity Sensor 3 2.2 Control Unit 4 2.3 System Operation

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

Refrigerator/Freezer Thermometer

Refrigerator/Freezer Thermometer The McKesson triple display digital thermometer simultaneously shows the current, minimum and maximum temperatures and updates continuously. An audible and visual alarm will trigger when the temperatures

More information

2-wire Passive Intelligent Loop (LED) Display Meter

2-wire Passive Intelligent Loop (LED) Display Meter Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter

More information

2017 Company Overview

2017 Company Overview 2017 Company Overview WHO IS SERVOFLO SERVOFLO IS A STOCKING DISTRIBUTOR PROVIDING TECHNICAL AND LOGISTICAL SERVICES FOR: Pressure sensors Mass Flow sensors Humidity sensors Temperature Sensors Micropumps

More information

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS SPECIFICATIONS Mountable with O-ring seal Stainless Steel wetted surfaces Amplified ASIC calibrated Absolute, sealed gage Cable option Analog output SENT Output Optional (contact factory for details) FEATURES

More information

HSD Dry Cabinet

HSD Dry Cabinet HSD 1106-52 Dry Cabinet Outstanding performance fast recovery time The HSD cabinet series has an outstanding performance for drying moisture sensitive components and pcb s as a result of a high performance

More information

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial

More information

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors 19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors DESCRIPTION Honeywell s stainless steel 19C, 19U, and 19 Vacuum Gage Series sensors were developed for pressure applications that involve

More information

DE20 INSTRUCTION MANUAL

DE20 INSTRUCTION MANUAL DE20 INSTRUCTION MANUAL Now UL Listed! SET POINT DE20 SET YOUR DISTRIBUTOR: Chemical Distributors, Inc. 80 Metcalfe Street - Buffalo, NY 14206 Phone: 800-777-2436 716-856-2300 Fax: 716-856-7115 sales@cdibuffalo.com

More information

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10 Fan Laws Keith Miller Samuel Tepp Associates Paul Cenci, P. E.-Principal Brian England-Principal Basic Terms CFM - Cubic Feet per Minute, volume (amount) of air being moved SP - Static Pressure, resistance

More information

0-10 V Wall & Duct Humidistat Installation Instructions

0-10 V Wall & Duct Humidistat Installation Instructions 0-10 V Wall & Duct Humidistat Installation Instructions This document covers the operation and installation instructions for the following Nortec Digital Humidistats: Part #: Description: 1510142 0-10

More information

Refrigerator/Freezer Thermometer

Refrigerator/Freezer Thermometer The McKesson triple display digital thermometer simultaneously shows the current, minimum and maximum temperatures and updates continuously. An audible and visual alarm will trigger when the temperatures

More information

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control FEATURES Low cost Rugged, isolated stainless steel package Small size Reliable semiconductor technology Calibrated and temperature compensated Absolute and gage pressures Vacuum compatible, isolated sensors

More information

SITE REPORT FOR CARE (CANADA) (Submitted by Rodica Nitu) Summary and purpose of document

SITE REPORT FOR CARE (CANADA) (Submitted by Rodica Nitu) Summary and purpose of document WORLD METEOROLOGICAL ORGANIZATION COMMISSION FOR INSTRUMENTS AND METHODS OF OBSERVATION INTERNATIONAL ORGANIZING COMMITTEE (IOC) FOR THE WMO SOLID PRECIPITATION INTERCOMPARISON EXPERIMENT (SPICE) Fourth

More information

SOP SF SOP for LN2 Freezers

SOP SF SOP for LN2 Freezers Page 2 of 9 4. SCOPE 4.1. The SOP applies to personnel operating and maintaining the liquid nitrogen freezers owned or contracted for storage in the SSF. This SOP is applicable to all vapor phase and liquid

More information

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES PROCESS ANALYZERS DF-340E The DF-340E is a Coulometric sensor based oxygen analyzer suitable for outdoor installation and designed to measure trace oxygen and percent level in pure and multigas backgrounds.

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Modus Model DA General Eastern Low Differential Pressure Alarm Controller GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam CM1107 Specification Working temperature -10 ~+50, 5~95%RH Introduction Dual beam (single light source, dual wavelength) CM1107 CO2 gas sensor module

More information

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy Contact person Björn Folkeson 2016-06-27 6P04381 1 (15) Energy and bioeconomy +46 10 516 54 46 bjorn.folkeson@sp.se Thermal Integration Ltd 8 Curzon Road Sudbury Suffolk CO10 2XW Great Britain Testing

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface Multi Parameter flow meters provide accurate data on three different fluid parameters: flow pressure temperature The flow rate can be displayed in volumetric flow or mass flow engineering units for standard

More information

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements IP TRONIK EICHSTÄTT GMBH Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements Christian Schwegler 17. October 2016 Table

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

MODEL GFC7000EU CO 2 ANALYZER

MODEL GFC7000EU CO 2 ANALYZER MODEL GFC7000EU CO 2 ANALYZER Teledyne Analytical Instruments 16830 Chestnut St. City of Industry, Ca. 91748 TEL: 626-961-9221 FAX: 626-961-2538 TEL: 626-934-1500 E-MAIL: ai-customerservice@teledyne.com

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FEATURES AND SPECIFICATIONS MOLYTEK 2702 AND 3702 RECORDERS 2702 3702 REV: 03302004 Standard Specifications for Model

More information

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features: GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,

More information

Dryer Master Inc. Dryer Master AM 3. Product Manual

Dryer Master Inc. Dryer Master AM 3. Product Manual Dryer Master Inc. Dryer Master AM 3 Revision 1.0 July, 2008 Revision 1.2 February, 2009 Revision 1.3 March, 2009 Revision 1.4 September, 2013 Prepared by: Dryer Master Inc. Dryer Master Inc 2008, 2009,

More information

RPM1600 Series Room Pressure Monitors

RPM1600 Series Room Pressure Monitors RPM1600 Series Room Pressure Monitors Technical Bulletin LB-RPM1611-0, LB--0 Code No. LIT-12012228 Issued October 2017 Refer to the QuickLIT website for the most up-to-date version of this document. How

More information

HYGROMER - MP 400 A Meteorology probe

HYGROMER - MP 400 A Meteorology probe HYGROMER - MP 400 A Meteorology probe Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 400A for measuring humidity and temperature, you have purchased a precision measuring

More information

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation. ACCL Participant: Date of Inspection: Test Stand Inspection Report Number: Approval Results: FORM ACCL-PC4 ACCL FACILITY APPROVAL PROCEDURE AND CHECKLIST AHRI CERTIFICATION PROGRAM FOR AIR-COOLED (ACCL)

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

Inductive Conductivity

Inductive Conductivity Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays

More information

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL REVISION DATE: JAN 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

ER52 - Evaporator Controller

ER52 - Evaporator Controller ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They

More information