1 SmartSensor 105 & Advance NEMA External Ice Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA external ice test on the SmartSensor 105 on April 7, Since the SmartSensor 105 and SmartSensor Advance use the same hardware platform, this report applies to both products. The following report documents the results of the test and is unedited by Wavetronix. Environ Laboratories LLC 9725 Girard Avenue South Minneapolis, Minnesota WX

2 "EXTERNAL ICING TEST" for WAVETRONIX, LLC 5314 NORTH 250 WEST PROVO, UT PREPARED BY: Daniel J. Larson Senior Test Technician APPROVED BY: David M. Gillen Vice President This document shall not be reproduced except in full, without the written authorization of Environ Laboratories LLC. ENVIRON LABORATORIES LLC Page 1 of FAX

3 REVISION HISTORY Revision Total Number Date Description of Pages May 2003 Original ENVIRON LABORATORIES LLC Page 2 of 8

4 PREPARED FOR: WAVETRONIX, LLC 5314 NORTH 250 WEST PROVO, UT ATTN: Mr. Don Christensen TEST DATES: Start: 4/7/2003 Completion: 4/7/2003 ENVIRON TEST NO.: PURCHASE ORDER NO.: 4435 PURCHASE DATE: 3/19/2003 EXTERNAL ICING TEST 1.0 ABSTRACT 1.1 Object Subject one (1) Enclosure to an External Icing Test in accordance with NEMA 250, Section 5.6, dated Conclusions Upon completion of the exposure the test unit showed no signs of damage or degradation. The test unit met the passing requirements of NEMA 250 for Type 6P Enclosures. 2.0 UNIT(S) TESTED MANUFACTURER: DEVICE: MODEL/PART NO.: WAVETRONIX, LLC Enclosure Smart Sensor Housing SERIAL NO.: The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number. ENVIRON LABORATORIES LLC Page 3 of 8

5 3.0 TEST REQUESTED Subject the test unit to the following Icing Test: NEMA 250, Section The enclosure shall to be mounted in a room that can be cooled to 20 F (minus 6.7 C). A metal test bar, which is 25.4 mm in diameter and 600 mm long, shall be mounted in a horizontal position in a location where it will receive the same general water spray as the enclosure under test. Provisions are to be made for spraying the entire enclosure from above with water at an angle of approximately 45 degrees from the vertical. The water shall be F. Spraying facilities that provide 1 2 gallons per hour per square foot of area to be sprayed have been found effective. The room temperature is to be lowered to 35 F. The water spray shall be started and continued for 1 hour, maintaining the room temperature between 33 F and 37 F. At the end of this time the room temperature shall be lowered to between 20 F and 27 F while continuing the water spray. The water spray is to be controlled as to cause ice to build up on the bar at a rate of approximately ¼ inch per hour and is to be continued until ¾ inch of ice has formed on the top surface of the bar. The spray is then to be discontinued, but the room temperature is to be maintained at F for 3 additional hours so that all parts of the enclosure and ice coating have reached the same temperature. ENVIRON LABORATORIES LLC Page 4 of 8

6 4.0 INSTRUMENTATION, PROCEDURE AND RESULTS 4.1 Instrumentation All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z and ISO/IEC 17025:1999. Equipment Number Description Manufacturer Model No. Last Calibration Due Calibration Range Temperature Chart Recorder Honeywell Truline DR45AT 1/22/2003 7/22/ to +300 F; 0 to 100% RH Temperature Controller Watlow 922 4/27/2001 4/27/ to F Stopwatch Radio Shack /16/2002 5/16/ to 10 Hours Temperature/ Humidity Chamber Thermotron WD N/A N/A -100 to +350 F; 20 to 99% RH 4.2 Procedure The test unit was mounted onto a post and placed into a temperature chamber in a manner to simulate actual installation. A 1-inch metal bar 2 feet long was then mounted near the test unit. A spraying system was then placed above the test unit and bar at an angle of 45. The internal chamber temperature was lowered to 35 F and the test unit was sprayed with water for a period of 1 hour. With the water still spraying the chamber temperature was lowered to 20 F and ice was allowed to start forming on the test unit and bar. The ice buildup was allowed to continue at a rate of ¼ inch per hour for 3 hours for a total of ¾ inch of ice buildup. The water spray was then discontinued and the test unit was held at 20 F for an additional 3 hours before a visual inspection was conducted. The chamber was then returned to ambient conditions and the test unit was again inspected. ENVIRON LABORATORIES LLC Page 5 of 8

7 4.3 Results Upon completion of the exposure the test unit showed no signs of damage or degradation. The test unit met the passing requirements of NEMA 250 for Type 6P Enclosures. ENVIRON LABORATORIES LLC Page 6 of 8

8 Photograph No. 1 - Test unit with ice buildup Photograph No. 2 - Test unit with ice buildup ENVIRON LABORATORIES LLC Page 7 of 8

9 Chart showing chamber temperature during exposure ( F) ENVIRON LABORATORIES LLC Page 8 of 8

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431 Engineering Report 47566-1 Vibration Test for Intertek Testing Services Prepared by Michael J. Caron, Test Engineer Lee R. Senne, Test Technician Approved by Kent L. Erickson, Dynamics Division Manager

More information

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager Engineering Report 49820-1 Vibration Test for Crystal Group Inc. Prepared by Michael J. Caron, Test Engineer Lee R. Senne, Test Technician Approved by Kent L. Erickson, Dynamics Division Manager This document

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1 Page No. TOC-i TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 1 1.1 Scope 1 1.2 References 1 1.3 Test Specimen Description 1 1.4 Summary 1 2.0 TEST PROCEDURES AND RESULTS 2 2.1 High Temperature Test 2 2.2

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3 Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Wall-Mount Pull-Out Test 4 2.2

More information

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA 1.0 INTRODUCTION This report presents the results of an investigation of the external fire resistance characteristics of the VELUX FCM Deck Mounted Skylight roof covering system in general accordance with

More information

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008 Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,

More information

ENVIRONMENTAL TEST REPORT

ENVIRONMENTAL TEST REPORT ENVIRONMENTAL TEST REPORT PO #: 0000025127 Quote #: 090206BH Test #: IDAH-090052 REV000 Idaho Technology February 23, 2009 PROPRIETARY Page 1 of 13 Idaho Technology 11 day Temp/Humidity Test APPROVALS

More information

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device

More information

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

23 PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT 23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT Model No. HIS-ML23- _ C Table of Contents Test Report Overview... 3 Testing Rationale...3 Test Plan...4 Test 1 Cold (Steady

More information

NATIONAL TECHNICAL SYSTEMS

NATIONAL TECHNICAL SYSTEMS Test Report Number PR034844.CRW Testing of Test Samples PREPARED FOR: PREPARED BY: Crownduit 214 William Street Red Bank, NJ 07701 National Technical Systems 36 Gilbert Street South Tinton Falls, NJ 07701

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

17 UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT 17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT Model No. HIS-UM17- _ E, HIS-UM17- _ F and HIS-UM17- _ G Table of Contents Test Report Overview... 3 Testing Rationale...3

More information

for Drinking Water Systems

for Drinking Water Systems Water Quality Measurement Solutions Instrument Overview Online UV%Transmission Analyzer for Drinking Water Systems HF scientific developed the AccUView UV%Transmission Analyzer specif ically to f ill the

More information

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product PERFORMANCE TEST REPORT Rendered to: EVERBLOCK SYSTEMS, LLC PRODUCT: Modular Block Product Report No.: G1320.01-106-31 Report Date: 08/04/16 Test Record Retention Date: 07/29/20 130 Derry Court York, PA

More information

WYLE LABORATORIES, INC. Huntsville Facility

WYLE LABORATORIES, INC. Huntsville Facility Page No. TOC 1 of 1 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION... 1 1.1 Scope... 1 1.2 Product Description... 1 1.3 References... 1 1.4 Compliance Summary... 2 2.0 SYSTEM TEST CONFIGURATION... 2 2.1 Details

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE ENGINEERING PTY LTD 90 Indian Drive Keysborough, Victoria 3173, AUSTRALIA Mr. Simon Grilj Phone: 61 3 9763 3079 Email: simon@compeng.com.au ELECTRICAL

More information

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures ON THE BUTTON A reference guide to environmental ratings used for push button enclosures A REFERENCE GUIDE TO KEY TOPICS IN PUSH BUTTON SELECTION AND SAFETY CONTENTS I. INTRODUCTION...............................

More information

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL ATTAR TEST REPORT NO: 10/4302 26 August 2010 Total Pages: 2 SLIP RESISTANCE Job No: M10/4302 Subject: Introduction: SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL You supplied us with two (2) samples of

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Product verification protocol: E06/TR04VP Applies to specification ref(s):

More information

DHR Accessories Requirements. Site Preparation Guide

DHR Accessories Requirements. Site Preparation Guide DHR Accessories Requirements Site Preparation Guide Revision C Issued May 2018 Table of Contents Table of Contents... 2 Smart Swap Requirements... 3 Air Chiller System (ACS)... 7-9 ETC Chiller Panel...

More information

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio PERFORMANCE TEST REPORT Report No.: F6398.01-121-24 Test Date: March 9 th & 10th, 2016 Rendered to: Metal Building Manufacturers Association Cleveland, Ohio ASSEMBLIES: Metal Roof Panels and Clay Roof

More information

Detailed Roof Report

Detailed Roof Report PRECISION ROOF CONSULTING, LLC WWW.PRECISIONROOFCONSULTING.COM PO BOX 520868 LONGWOOD, FL 32752 Detailed Roof Report Provided by: www.precisionroofconsulting.com Precision Roof Consulting Page 1 of 5 PRECISION

More information

TEST REPORT: CHM14-05-CHY

TEST REPORT: CHM14-05-CHY A TEST REPORT: 7191100863-CHM14-05-CHY Date: Tel: +65 68851291 Fax: +65 67784301 Client s Ref: Email: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations

More information

Test report no.: Plug and key - Damp heat test

Test report no.: Plug and key - Damp heat test r Yebotech 14405.docx Test report no.: 14405 Plug and key - Damp heat test EDITION 1 PAGE 1 OF 4 Tel: +27 (0)12 371 2000 Fax: +27 (0)12 371 2001 www.gerotek.co.za WF Nkomo Street Pretoria West P O Box

More information

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement

More information

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112

More information

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly ASTM E119-98: Standard Test Methods for Fire Tests of Building Construction and Materials* *Research-scale horizontal

More information

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006 Report No.:RA-S9504-0992 Reliability Engineering Division Page: 1 of 5 1F, No.22, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C. http://www.isti.com.tw Company Model Name :A27 DUST TEST REPORT :Gold Apollo

More information

Blow Ice Detection and Advanced Warning System

Blow Ice Detection and Advanced Warning System Blow Ice Detection and Advanced Warning System Requirements Final MnDOT OTST MnDOT District 8 September 2013 SRF No. 8221 Table of Contents Glossary... 1 Purpose and Scope... 2 Document Purpose... 2 Project

More information

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Kolay 5mm 20mil Wear Layer LVT with Fiberglass Core Project

More information

TEST REPORT: CHM14-07-CHY

TEST REPORT: CHM14-07-CHY A TEST REPORT: 7191100863-CHM14-07-CHY Date: Tel: +65 68851291 Fax: +65 67784301 Client s Ref: Email: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations

More information

Contact person Date Reference Page Henrik Andersson F (4) Electronics

Contact person Date Reference Page Henrik Andersson F (4) Electronics issued by an Accredited Testing Laboratory Contact person Henrik Andersson 2016-05-19 6F009034 1 (4) Electronics +46 10 516 55 74 henrik.andersson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 ENOC SYSTEM

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E06/TR04.1 Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Specification reference: E06/TR04.1 Product verification protocol:

More information

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate PERFORMANCE TEST REPORT Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate Report No: C7626.1-16-31 Report Date: 5/8/13 Test Record Retention Date: 5/8/17 PERFORMANCE TEST REPORT

More information

WASTEWATER Online UV%Transmission Analyzer

WASTEWATER Online UV%Transmission Analyzer Water Quality Measurement Solutions Online UV%Transmission Analyzer Detailed Specifications Instrument Overview With over 30 years of optical design technology expertise HF scientific has developed it's

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70067850 Date Issued: July 28, 2017 Issued to: Otis Instruments, Incorporated 301 S. Texas Ave. Bryan, Texas, 77803 USA Attention: Nicholas Sandera The products listed

More information

WH-1404, Rev. Feb 97

WH-1404, Rev. Feb 97 WH-1404, Rev. Feb 97 Page No. i REVISIONS REPORT NO. T56737 DATE December 20, 2011 REV DATE PAGE OR PARAGRAPH AFFECTED BY APP'L DESCRIPTION OF CHANGES A 12/16/11 Cover Page Changed total of pages and title.

More information

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details Test Report Report No 288/7387780 Part 1 of 2 This report consists of 22 pages Licence/Certificate No KM 532936 Client GLT Exports Limited 72-78 Morfa Road Hafod Swansea SA1 2EN United Kingdom Authority

More information

Field Study of An Intelligent, Networked, Retrofittable Water Heater Controller

Field Study of An Intelligent, Networked, Retrofittable Water Heater Controller Field Study of An Intelligent, Networked, Retrofittable Water Heater Controller ACEEE Hot Water Forum - Portland, OR Ben Schoenbauer CEE & David Kalensky, GTI February 2017 Acknowledgements This project

More information

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor Page 1 DOE/NV/XXXXX--XX Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor Robert B. Hayes, Ph.D., CHP, PE Senior Scientist Remote Sensing Laboratory PO Box 98521, Mail Stop RSL-47

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that LabTest Certification, Inc. 3128 20800 Westminster

More information

Performance Report 2009 Chimfex

Performance Report 2009 Chimfex Performance Report 29 Chimfex May, 29 Prepared for: Terry Jones, Operations Mgr Orion Safety Products 2832 Saint Michaels Rd Easton, MD 2161 P: 41-822-318 E: terry@orionsignals.com Terry, OMNI Environmental

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

CR7075 Two-Stage Lighting Controller

CR7075 Two-Stage Lighting Controller CR707 Two-Stage Lighting Controller FEATURES PRODUCT DATA Light intensity threshold levels field-adjustable by user. Independent Time of Day (TOD) override inputs. Optimum start/stop of lighting loads.

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015 Supertron Sensing Pte Ltd Certificate No. : LA-2011-0485-C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore 339156 Date : 04 February 2015 Page : 1 of 5 FIELD OF TESTING : Calibration and Measurement

More information

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number:

More information

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015 REPORT NUMBER: 101960325MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 TEST REPORT

More information

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air. Cover Sheet Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air. PURPOSE: Some earlier generation air purifiers, have been shown to release ozone or secondary

More information

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer JAN 0 ::0 AM SERVOLOCK APPLICATION NOTE 0_0_ Rev Using the Deluxe Dew Point/ Humidity Hygrometer The Model is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously measure

More information

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM LABORATORY FREE ZERS LABORATORY FREEZERS -30 O C i.series TM Horizon Series TM introduction LABORATORY FREEZERS -30 O C helmer laboratory freezers provide the following benefits: Programmable Defrost Times

More information

CO 2 Incubators: 7401, 7402 & 7403 Series

CO 2 Incubators: 7401, 7402 & 7403 Series CO 2 Incubators: 7401, 7402 & 7403 Series optimized FOR applications WITH SHAKERS AND CELL ROLLERS Product line overview & Standard features Caron s Reach-in Shaker Ready and Cell Roller Ready CO 2 Incubators

More information

Fire Smoke Damper Actuator Replacements SECTION COMMISSIONING OF HVAC

Fire Smoke Damper Actuator Replacements SECTION COMMISSIONING OF HVAC PART 1 GENERAL 1.01 SUMMARY SECTION 23 08 00 COMMISSIONING OF HVAC A. This section covers the Contractor's and Commissioning Authority (CA) responsibilities for commissioning; each subcontractor or installer

More information

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing Temperature Sensors & Compression Seal Fittings for Semiconductor Processing The Quality and Performance Leader Email: semisales@conaxtechnologies.com Website: www.conaxsemiconductor.com 1 Conax Semiconductor

More information

MATERIAL EVALUATION REPORT STATIC DECAY, RESISTANCE AND TRIBOELECTRIC CHARGE GENERATION TESTING OF MERINO ESD LAMINATE SAMPLES MERINO INDUSTRIES, INC.

MATERIAL EVALUATION REPORT STATIC DECAY, RESISTANCE AND TRIBOELECTRIC CHARGE GENERATION TESTING OF MERINO ESD LAMINATE SAMPLES MERINO INDUSTRIES, INC. MATERIAL EVALUATION REPORT STATIC DECAY, RESISTANCE AND TRIBOELECTRIC CHARGE GENERATION TESTING OF MERINO ESD LAMINATE SAMPLES MERINO INDUSTRIES, INC. JUNE 6, 2011 1 MATERIAL EVALUATION REPORT Static Decay,

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Kaba Mas X-10/CDX-10/DKX-10. Type 1F High Security Electronic Locks FF-L-2740B/ FF-L-2890B

Kaba Mas X-10/CDX-10/DKX-10. Type 1F High Security Electronic Locks FF-L-2740B/ FF-L-2890B Kaba Mas X-10/CDX-10/DKX-10 Type 1F High Security Electronic Locks FF-L-2740B/ FF-L-2890B X-10 features a Backlit LCD Display! Poorly lit areas make it difficult to see a lock s visual control, and temporary

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE CERTIFICATION SERVICES INC. 1 Kunshan Laboratory No. 10 Wei ye Road Innovation Park Eco & Tec. Development Zone Kunshan City, Jiangsu, People s Republic

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1 ARES-G2 Rheometer Site Preparation Guide A Issued June 2016 1 1 A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility

More information

1022 R/T Remote Monitor

1022 R/T Remote Monitor 1022 R/T Remote Monitor INSTRUCTIONS AMC-1022R/T WITH REMOTE SENSOR OR TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS FOR THE AMC-1022R/T UNIT IMPORTANT: Please read these installation and operating

More information

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL BURNING BRAND PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR 022 0000 (Acrylic Dome) VELUX SUN TUNNEL ACCESSORY PRODUCTS: Tubular Skylight with ZTA 022 000090 9" Turrets

More information

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014 Test Report Report No Client Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK Authority & date SMO 8149837 07/04/2014 Items tested CDA/CO/1 - RESitech-

More information

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota Architectural Testing TEST REPORT Report No.: D7913.05-121-24 Rendered to: 3M COMPANY St. Paul, Minnesota PRODUCT TYPE: Window Film SERIES/MODEL: 3M Scotchshield Ultra 800 TEST METHOD: ASTM E 84-11a, Standard

More information

Equipment specifications (D6)

Equipment specifications (D6) Equipment specifications (D6) This report has been produced for the Cyprus Research Promotion Foundation in fulfilment of deliverable number D6 of the project Advanced Photovoltaics Research and Testing

More information

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output Model LFS108B Copyright 2018 - LLC. All rights reserved. Table of Contents Quick Start... 3 1- Introduction... 4 2-

More information

Slip Resistance Tests on Coated Panels. Duram. for. Date: 4th August Your Reference Number: Document Reference Number:

Slip Resistance Tests on Coated Panels. Duram. for. Date: 4th August Your Reference Number: Document Reference Number: Slip Resistance Tests on Coated Panels for Date: 4th August 2006 File Reference Number: Your Reference Number: Document Reference Number: M0568R1 Slip Resistance Tests on Coated Panels for Prepared and

More information

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES TITLE OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) TYPE STANDARD OPERATING PROCEDURE NUMBER 4700 DATE JANUARY 1995 AUTHORIZATIONS

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101786356 Date: August 19, 2014 REPORT NO. 101786356LAX-001 TEST OF

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 260923 - LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008 Reliability Laboratory Page: 1 of 5 Date: December 23, 2008 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT No. 588 West Jindu Road, Songjiang District, Shanghai, China Telephone: +86 (0) 21 61915666 Fax: +86 (0) 21 61915678 ee.shanghai@sgs.com Page 1 of 8 1 Cover Page Application No.: Applicant: FCC MPE REPORT

More information

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Process Control PIP PCEA001 Fixed Gas Detection Guidelines November 2015 Process Control PIP PCEA001 PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical

More information

Infrared Moisture Balance (FD-800)

Infrared Moisture Balance (FD-800) Dual Temperature Control Moisture Analyzer (FD-800) FD-800 is premium infrared moisture determination balance which employs a revolutionary dual temperature sensor method to enable high precision moisture

More information

Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet

Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet 1 Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet Figure 1 Ice*Meister Model 9734-SYSTEM optical ice sensing detector system is easy to install and completely

More information

Air Resource Specialists, Inc.

Air Resource Specialists, Inc. Air Resource Specialists, Inc. Optec NGN-2A Nephelometer Support Systems Price List July 2006 FULLY INTEGRATED OPTEC NGN-2A MONITORING AND DATA LOGGING SUPPORT SYSTEMS (costs do not include the Optec NGN-2A

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS. TOWER DRYERS TOTAL VALUE. TOTAL SYSTEMS. 1 GSI FEATURES 1 Gravity inlet does not require leveling auger, reducing the number of moving parts. 2 3 2 Self cleaning cushion box on plenum roof reduces grain

More information

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewTrak II Dew Point/ Humidity Transmitter APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.

More information

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests For Innovative Textiles Fabric system Outer Layer: 5.5 oz/yd² IUS Twill, 88% Cotton 12% Nylon, Style 341, Khaki. 6.6 oz/yd² Inner Layer: 6.5 oz/yd²

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

TESTS OF ADSIL COATING

TESTS OF ADSIL COATING TESTS OF ADSIL COATING Test B - Long Term Test FSEC-CR-1259-01 July 11, 2001 Prepared for: Bob Suggs Florida Power & Light Company 9250 W. Flagler Street Miami, Florida 33174 Principal Investigator Dr.

More information

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology. NRRPT Exam Review Class - an intensive 5-day class designed to prepare the candidate to successfully pass the NRRPT Exam. The course concentrates on the basic tools the candidate needs to successfully

More information

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria TEST REPORT Report No.: E6736.01-121-24 Test Date: May 6, 2015 Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria PRODUCT TYPE: Max Exterior F-Quality SERIES/MODEL: Décor. 0085 TEST METHOD:

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E006/TH06.2 Original: English Distribution: General TITLE: Integrated electronic thermometer, with or without alarm function, for vaccine refrigerators and freezers

More information

- TECHNICAL NOTES SUPPLEMENT TO PROJECT WORKSHEET -

- TECHNICAL NOTES SUPPLEMENT TO PROJECT WORKSHEET - Bahnson Environmental Specialties, LLC. 4412 Tryon Road Raleigh, NC 27606-4218 919.829.9300 Fax: 919.829.7357 Sales/Project Fax: 919.833.9476 www.eschambers.com - TECHNICAL NOTES SUPPLEMENT TO PROJECT

More information

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY Page: 1 of 5 1. Risk Assessment: Operation of Centrifuge TASK PERFORMED HAZARDS 1. Severe machine imbalance leading to machine destruction and possible injury to those in the vicinity 2. Exposure to biohazards/hazardous

More information

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3 REPORT NUMBER: 101207560COQ-001b ORIGINAL ISSUE DATE: June 12, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Vipco Industries

More information

Applications Engineering Notes

Applications Engineering Notes Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective

More information

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR OF TEST PROGRAM DEVELOPMENT CONTECH RESEARCH, INC. ATTLEBORO,

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

ENVIRONMENTAL TEST REPORT

ENVIRONMENTAL TEST REPORT MECHANICAL TESTING 0839.04 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com ENVIRONMENTAL TEST REPORT ACCORDING

More information

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors by The Leading Enterprise Internet of Things Solution DUCT TEMPERATURE Wireless Duct Temperature Sensors General Description The ALTA Wireless Duct Temperature Sensor uses an NTC thermistor with 8 ft.

More information

EC S 040 A. Installation Instructions 1-1. General Information. Model Numbers. Model Numbers Identification. This manual covers the following models:

EC S 040 A. Installation Instructions 1-1. General Information. Model Numbers. Model Numbers Identification. This manual covers the following models: Section 1 General Information It is recommended that this ice machine be inspected and installed by a qualified service technician. Installation Instructions Follow all recommendations and instructions

More information

Application Notes For LED Displays

Application Notes For LED Displays Through Hole Display Mounting Method Lead Forming Do not bend the component leads by hand without proper tools. The leads should be bent by clinching the upper part of the lead firmly such that the bending

More information

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems Your Presenter: Merton Bunker, PE Inspections and tests are intended to reduce or limit: Loss of life

More information

DMFPM-2R MULTIFUNCTIONAL

DMFPM-2R MULTIFUNCTIONAL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information