Referens projects. Powerpoint Templates

Size: px
Start display at page:

Download "Referens projects. Powerpoint Templates"

Transcription

1 Referens projects Powerpoint Templates

2 Teknoware Ltd Lightning factory New building, 2016

3 Passive preheating & cooling from gound and heat recovery from exhaust air to supply air

4 TK152 Monitoring system

5 TK152 Monitoring system

6 TK152: Preheating & cooling coils & Heat Recovery coils l/s

7 Need for 1300 mm service space above the Retermia housing coils

8 View from the roof 6 pcs HR- fans, 2 pcs RETCARE OUT E

9 ATEX- exhaust fans RETCARE OUT E

10 RETCARE OUT E

11 RETCARE OUT E

12 TK152 Heat recovery Retermia hydraulic unit

13 TK154 Hall for metal works, l/s & l/s

14 TK154 Monitoring system

15 TK154 Heat recovery Retermia hydraulic unit

16 KUOPIO UNIVERSITY HOSPITAL Kuopio, Finland. Retrofit installation 2010.

17 KUOPIO UNIVERSITY HOSPITAL Kuopio, Finland. Retrofit installation 2010.

18 Heat recovery & RETCOOL for 5 AHU s piping diagram

19 Outdoor air intake: Before installation

20 Air intake after installation: Retermia heat recovery and cooling system for five existing supply and exhaust AHU s. Air flow 22 m 3 /s

21 Air intake after installation: Retermia heat recovery and cooling system for five existing supply and exhaust AHU s. Air flow 22 m 3 /s Service hatch Service platform

22 Air intake after installation: Retermia heat recovery and cooling system for five existing supply and exhaust AHU s. Air flow 22 m 3 /s Air side pressure loss of Retermia coils 48 Pa with maximal airflow rate 22 m 3 /s.

23 Exhaust air side after installation: Retermia needle heat exchangers installed instead old exhaust air louvres serving five existing exahust AHU s.

24 Heat recovery & cooling: Chiller & buffert tank

25 KUOPIO UNIVERSITY HOSPITAL Kuopio, Finland. Retrofit installation ε = 0 (0,4 + 22,5) C 0 (23,9 + 22,5) C *100% = 49%

26 CASE: Mc Donald s Järvenpää, Finland. New building 2009

27 Heat recovery & RETCOOL for 2 AHU s piping diagram

28 Supply side: Needle heat exchanger installed at the outdoor air intake

29 Supply side: Needle heat exchanger installed at the outdoor air intake

30 Exhaust side: 2 heat recovery fans: kitchen & dining hall

31 Exhaust side: 2 heat recovery fans: kitchen & dining hall

32 Kitchen HR- fan: the needle coil surface

33 Annual service of kitchen HR- fan

34 Pump, expansion vessel, filling station for brine

35 Monitoring system: Kitchen supply AHU

36 Monitoring system: Dining hall AHU

37 VAASAN & VAASAN OY BAKERY New production 2007

38 VAASAN & VAASAN OY New production 2007

39 VAASAN & VAASAN OY New production 2007

40 VAASAN & VAASAN OY New production 2007

41 VAASAN & VAASAN OY Technical room for supply & extract AHU:

42 VAASAN & VAASAN OY Supply side: 2 Retermia housing coils. Installed at the air intake.

43 VAASAN & VAASAN OY Exhaust side: 2 section Retermia housing coil in the RETCARE air handling unit. 3-row deep Retermia coil 1-row deep Blygoldcoated Retermia coil

44 VAASAN & VAASAN OY Monitoring system Note! There is 23 % more supply air that exhaust air

45 Arlanda Airport, Sweden

46 Arlanda Airport, Sweden Terminal 5, Southern air intake Air flow rate 40 m3/s. Heat recovery system from exhaust air to supply air. Renovation project, 2007.

47 Air intake from the roof

48 A wall of Retermia coils installed in intake chamber. Air flow rate 40 m3/s

49 A wall of Retermia coils installed in intake chamber. Air flow rate 40 m3/s

50 Arlanda Airport, Sweden Piping system Pump station Monitoring of recovered energy

51 Arlanda Airport, Sweden

52 Arlanda Airport, Sweden Akvifär system

53 Arlanda Airport, Akvifär system Akvifär is the biggest thermal energy storage in the world. The storage of thermal energy is based on ground water wells. The system saves electricity approximately 4 GWh per year. The system saves heat energy GWh per year. HVAC design: Sweco Theorells Ab

54 Arlanda Airport, Akvifär system Passive heating of supply air during winter time. The system uses energy from energy wells and from cooling systems return pipe to preheat the supply air. Passive cooling of supply air. The system uses cooling energy from the ground to cool the supply air. Arlanda Norra Intaget (2007): SkyCity (2011): 50 m 3 /s supply air 2 x 50 m 3 /s supply air Air volume flow rate varies between 30 and 50 m 3 /s per air intake. Brine flow rate for needle coils varies between 9 and 55 l/s per air intake. Small air and brine side pressure losses at wide opeation range were reasons why the designer selected Retermia coils.

55 Wall of needle coils in air intake chamber. Air flow rate m 3 /s

56 Akrifär, use during winter Thermal energy from the return cooling system is used for preheating of supply air. Heat from Akvifär is used for preheating supply air and melting aeroplane parkings slots. The return water from airport to Akvifär is cooled with Halmsjölake water below +5 C temperature before it returns to Akvifär. The cooled water in the akvifer system is transferred to another part of the energy storage where the cooling energy is stored for the summer use.

57 Arlanda Airport, Akvifär system

58 Akrifär, use during winter

59 Akrifär, use during summer The return water of cooling system is used for pre- cooling the supply air. with needle coils. Cooling of supply air with Akvifär energy storages cooling energy. The warmed water in the akvifer system is transferred to another part of the energy storage where the heat energy is stored for the winter

60 Akrifär, use during summer

61 Thank you for your interest!

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST THE TRADITIONAL HEAT RECOVERY COIL SYSTEM SHALL BE UPDATED TO COME UP TO REQUIREMENTS OF THE ECODIRECTIVE. HIGH EFFICIENCY UNDER LOW OPERATING TEMPERATURE DEMANDS A NEW IMPROVED CONCEPT TO PREVENT FREEZING

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox Oy manufactures ventilation units Vallox TSK Multi 80 MC Certificate No VTT-C-11032-14 Translation 1 (2) Vallox TSK Multi 80 MC is intended to be used

More information

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb Kalle Kuusk 1, Jaanus Hallik 2, Targo Kalamees 3, Tõnu Mauring 4, 1,3

More information

nzeb office building

nzeb office building nzeb office building Ympäristötalo in Helsinki, Finland City of Helsinki has taken the exemplary role of the public sector seriously. The latest proof is the Environment Centre building Ympäristötalo completed

More information

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and

More information

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden Efficient energy recovery in AHU DOHA, Qatar 11.04.2010 Timo Schreck Enventus AB, Sweden Main principles for cooling and dehumidification process in AHU 1. With cooling coil and reheater 2. Energy recovery

More information

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit.

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit. ECONET PREMIUM TROUBLE-SHOOTING: Start by checking all indata for the air handling unit. 2 Air temperatures/humidity Outdoor air temperature C Thermometer or AHU/Econet Supply air temperature C Thermometer

More information

Flexomix A versatile range of modular air handling units

Flexomix A versatile range of modular air handling units Flexomix A versatile range of modular air handling units We've been saving the Earth's resources for over forty years Copenhagen Airport, Harpa Concert Hall in Reykjavik, sports arena's, schools, offices,

More information

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Smoke Master SMIA Compact pressurisation and smoke exhaust system Smoke Master SMIA Compact pressurisation and smoke exhaust system Fläkt Woods FIFLO EN 2009.09 2 All rights reserved. Contents System overview... 4 Design and operation... 5 Technical specification...

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical Vallox 150 Effect SE MLV Vallox 150 Effect SE MLV Vallox Oy manufactures Certificate No VTT-C-3514-08 Translation 1 (2) ventilation units Vallox 150 Effect SE MLV (preheating with ground heat) Vallox 150

More information

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W:   T: Eco Active Heat Recovery Penthouse Turret W: www.gdl.co.uk T: 01457 861538 Heat Recovery Penthouse Turret The HRPT provides ventilation into spaces all year round. The unit provides 100% fresh air whilst

More information

Smoke extract fan SMHA HATCH

Smoke extract fan SMHA HATCH 12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10

More information

HEAT RECOVERY & POWERED VENTS

HEAT RECOVERY & POWERED VENTS HEAT RECOVERY & POWERED VENTS HEAT RECOVERY VENTING TOPICS HEAT RECOVERY DEFINITION HOW HEAT IS LOST WHILE DRYING HOW IS THE KILN BEING VENTED WHERE IS ENERGY CONSUMED WAYS TO PREVENT ENERGY LOSS POWER

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

Munters DesiCool removes excess heat in server room

Munters DesiCool removes excess heat in server room Munters DesiCool removes excess heat in server room DesiCool Corporate IT in Copenhagen University is bringing all their servers into two large server rooms located respectively in Copenhagen University

More information

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available

More information

The Clivet Enhanced Hydronic System March 20th Inserire immagine

The Clivet Enhanced Hydronic System March 20th Inserire immagine The Clivet Enhanced March 2th 215 Inserire immagine WHAT S THE ENHANCED HYDRONIC SYSTEM The Hydronic System is a pre-configured modular system which is composed of three basic equipments: - ZEPHIR 3 stand-alone

More information

GreenMaster HP Exhaust air heat pump for residential properties

GreenMaster HP Exhaust air heat pump for residential properties GreenMaster HP Exhaust air heat pump for residential properties Air-Site We are a Swedish company that likes air and energy recovery. That's why we develop products that use air to heat, cool and provide

More information

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit 28 May 2013 Agenda Introduction to Fläkt Woods Our Product Solution Technical Features Benefits Fläkt Woods Index We save energy!

More information

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure COMPACT AIR HANDLING UNIT CompAir RW Technical Brochure Version 1.4 January 2013 INDEX: 1 GENERAL... 4 2 COMPAIR RW 2000... 8 2.1 Technical specification... 8 2.2 External static pressure/air volume diagram...

More information

Smoke Master SMPA Compact pressurisation system

Smoke Master SMPA Compact pressurisation system Smoke Master SMPA Compact pressurisation system Fläkt Woods FILO E 2009.07 2 All rights reserved. Contents System overview...4 Design and operation...5 Technical specification...6 Electric and control

More information

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder HVAC DISTRIBUTION and DELIVERY SYSTEMS (Part 2) Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1 Contextual Reminder All-air systems Single zone Terminal reheat Multi-zone Dual-duct VAV Combinations

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart! NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart! WWW.SALDA.LT 2016 Ver. A SECTION OF THE ROTARY HEAT EXCHANGER WITH THE HEAT PUMP: ideal solution targeting multiple goals In conventional

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

Koja Oy. manufactures ventilation units Fair 80 ec

Koja Oy. manufactures ventilation units Fair 80 ec Koja Fair 80 ec Koja Fair 80 ec Koja Oy manufactures ventilation units Fair 80 ec Certificate No VTT-C-8424-12 Translation 1 (2) Fair 80 ec is intended to be used as a ventilation unit of a dwelling. Efficiency

More information

Modular prefab integrated HVAC units: description and development of demonstration units (D2.3)

Modular prefab integrated HVAC units: description and development of demonstration units (D2.3) Modular prefab integrated HVAC units: description and development of demonstration units (D2.3) Development and advanced prefabrication of innovative, multifunctional building envelope elements for MOdular

More information

Solutions for a WORRY FREE HATCHERY. HatchVAC. No one knows HVAC like

Solutions for a WORRY FREE HATCHERY. HatchVAC. No one knows HVAC like Solutions for a WORRY FREE HATCHERY No one knows HVAC like Jamesway has long been the gold standard for incubators. Since 1915 we have been implementing the best machines and equipment to ensure that you

More information

PFS Single stage axial fan The axial fan for modern boiler plants

PFS Single stage axial fan The axial fan for modern boiler plants PFS Single stage axial fan The axial fan for modern boiler plants This large axial fan, type PFS- 400-236, was installed in 1987 at the Salmisaari coal-fired power station in Helsinki, Finland. The photo

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

Heat Recovery Ventilation: Fresh Healthy Indoor Air with all the Savings

Heat Recovery Ventilation: Fresh Healthy Indoor Air with all the Savings : Fresh Healthy Indoor Air with all the Savings Oliver Joss September 2017 Introduction Oliver Joss Born in Aarau, Switzerland on 28 April 1972 Married & two boys Currently living in Melbourne Professional

More information

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one GOLD RX/HC The air handling unit with a reversible heat pump Ventilation, heating and cooling all in one All in one Ventilation, heating and cooling in a single package There are many different solutions

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Overview Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Demand-controlled ventilation offers great comfort and low operating costs When the room is in use, ventilation

More information

Zehnder Comfosystems. ComfoAir 180 Datasheet

Zehnder Comfosystems. ComfoAir 180 Datasheet Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an

More information

HVAC product labelling and certification

HVAC product labelling and certification 1/ 2011 HVAC product labelling and certification Sylvain COURTEY s.courtey@eurovent-certification.com Eurovent Certification Company (ECC) www.eurovent-certification.com Summary 2/ 2011 1. Labelling directives

More information

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment.

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment. s Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel s LIVING For heat recovery in multi-occupancy buildings with extract air ventilation.

More information

Air heater/cooler in combination with ground source heat pump

Air heater/cooler in combination with ground source heat pump Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN

More information

Technical Report Three

Technical Report Three Technical Report Three Existing Conditions for Mechanical Systems Contents Executive Summary...2 Building Overview...2 Mechanical Systems Overview...2 Mechanical System...3 Outdoor & Indoor Design Conditions...3

More information

Quality Products AHU Repair, Refurbishment and Replacement

Quality Products AHU Repair, Refurbishment and Replacement Quality Products AHU Repair, Refurbishment and Replacement We are engineers specialising in the repair, refurbishment and replacement of ventilation systems. We have considerable experience in solving

More information

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney Frenger Radiant chilled beam performance at 3D Model Creation Daylight Analysis Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled

More information

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2

More information

Building Regulations Approved Document F1 Means of Ventilation April 2006

Building Regulations Approved Document F1 Means of Ventilation April 2006 Building Regulations Approved Document F1 Means of Ventilation April 2006 BPD Structure BUILDING PRODUCT DESIGN LTD 4 trading divisions.. Natural ventilation products and systems Roofing products, flat

More information

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story

More information

Enervent HP. Technical Data and additional information to Enervent eair Installation Instructions

Enervent HP. Technical Data and additional information to Enervent eair Installation Instructions 27.12.2016 Enervent HP EN Technical Data and additional information to Enervent eair Installation Instructions 2 Contents READ ME FIRST...4 GENERAL...4 MAINTENANCE......................................................................................................4

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING ASHRAE s BEST This article was published in ASHRAE Journal, November 2010. Copyright 2010 American Society of Heating, Refrigerating and -Conditioning Engineers, Inc. Reprinted here by permission from

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

Chilled Ceilings / Beams Working Principles & Applications

Chilled Ceilings / Beams Working Principles & Applications 5 th International Conference on Energy Sustainable Energy Polices and Technologies 15-17 October 2014 Chilled Ceilings / Beams Working Principles & Applications Francis W H Yik ATAL Building Services

More information

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2 AIR HANDLING UNITS DESIGN System INFORMATION No off Access Handing Viewed in direction of supply air Finish / Colour Duct Connections Height: Width Velocity: Design Airflow (m3/s) Supply Fan Ability Supply

More information

Daikin Blueprint: Delivering Hot Water with a Chiller

Daikin Blueprint: Delivering Hot Water with a Chiller Daikin Blueprint: Delivering Hot Water with a Chiller Analyzing the design of heat recovery on air-cooled chillers and the effect it has on building energy consumption By Paul Crisman Daikin Chiller Applications

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces

More information

2009 IECC Commercial Mechanical Requirements

2009 IECC Commercial Mechanical Requirements BUILDING ENERGY CODES UNIVERSITY 2009 IECC Commercial Mechanical Requirements Ken Baker PNNL-SA-66171 Learning(Objec-ves(( ( 1. Find(minimum(equipment(efficiency(requirements( and(recite(at(least(3(common(terms(for(measuring(

More information

Implementation of the Laboratory Air Handling Unit Systems (LAHU)

Implementation of the Laboratory Air Handling Unit Systems (LAHU) University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Architectural Engineering -- Faculty Publications Architectural Engineering 2003 Implementation of the Laboratory Air Handling

More information

HVAC Mandatory Provisions Part II, Page 1

HVAC Mandatory Provisions Part II, Page 1 HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency

More information

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Temperature. In the HVAC area, we talk about two kinds of temperatures. HEATING and COOLING HEATING and COOLING PSYCHROMETRIC CHART Temperature In the HVAC area, we talk about two kinds of temperatures. One is called dry bulb (DB) temperature, a fancy name for the reading

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1

More information

Planning guide. (2010/09) en

Planning guide. (2010/09) en Planning guide (2010/09) en 1 Planning guide for Greenline HE E 21, 28 and HE D 36, 43 Page Contents 3 Documentation and VPW2100 4 Technical data of heatpump 5 Dimensioning of DHW systems 6 Symbol explanations

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

ACCUBLOC high performance Heat Recovery

ACCUBLOC high performance Heat Recovery 2013-3.1 Accubloc ACCUBLOC high performance Heat Recovery Contents Page 2 3 5 6 7 Contents Accubloc description Accubloc principle Engineering information Control using the control unit Engineering Specifications

More information

Energy Recovery Ventilators

Energy Recovery Ventilators Energy Recovery Ventilators Models ERM, MiniVent, ERV and ERVe Untempered Preconditioners September 2016 Energy Recovery Ventilators Greenheck offers a complete line of energy recovery ventilators to reduce

More information

NATURAL VENTIL ATION. commercial louvres solar shading design consultancy sales and installation natural ventilation

NATURAL VENTIL ATION.  commercial louvres solar shading design consultancy sales and installation natural ventilation NATURAL VENTIL ATION commercial louvres solar shading design consultancy sales and installation natural ventilation 3/109 Ledger Road Beverley SA 5009 enquires@ecsystems.com.au phone 08 8243 0011 fax 08

More information

Gas Heat Pump (GHP) Presented for Panasonic Heating & Cooling Systems by Lee Howes Consultant Sales Engineer

Gas Heat Pump (GHP) Presented for Panasonic Heating & Cooling Systems by Lee Howes Consultant Sales Engineer Gas Heat Pump (GHP) Presented for Panasonic Heating & Cooling Systems by Lee Howes Consultant Sales Engineer lee.howes@eu.panasonic.com Overview GHP Introduction Applications Features, benefits and advantages

More information

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MEETING THE HIGHEST DEMANDS - EFFICIENT HVAC SOLUTIONS FOR ARCTICAL TO TROPICAL CONDITIONS AT FLÄKTGROUP WE WANT TO EXCEED the

More information

Mold/Moisture Control Case Study

Mold/Moisture Control Case Study Mold/Moisture Control Case Study Presented by Boggarm S. Setty, P.E., FASHRAE Setty & Associates, Ltd. www.clima2005.ch Clima 2005 Lausanne Solothurnstrasse 13 CH-3322 Schönbühl Switzerland th 8 REHVA

More information

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID AIR DIFFUSION CHILLED BEAMS A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY iq Star Wega II iq Star Nova II iq Star Lyra II iq Star Stella Flexicool IQID 2 CHILLED BEAMS by FLÄKTGROUP TOP

More information

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+ INSTALLATION AND OPERATING INSTRUCTIONS Ariterm 60+ CONTENTS General.... 2 Installation.... 4-5 Installation of temperature limit valve... 6 Measurements and connections... 7 Technical specifications and

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

Challenges and Methods of Estimating a Conceptual HVAC Design

Challenges and Methods of Estimating a Conceptual HVAC Design Challenges and Methods of Estimating a Conceptual HVAC Design ABSTRACT In any conceptual HVAC design, estimators are faced with the challenge of trying to capture all of the pieces that complete a system.

More information

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for PERFORMANCE The new generation of MVHR units - ComfoAir Q Introduction

More information

Presentation On Industrial Boiler Operation And Maintenance

Presentation On Industrial Boiler Operation And Maintenance Presentation On Industrial Boiler Operation And Maintenance Supervised By: Engr. Poresh Kanti Das GM-MAL RIP, Mulgoan, Kaligonj, Gajipur Boiler fundamental. Assessment On Heat recovery Boiler. Boiler Operation.

More information

Zehnder ComfoAir 550. Ventilation unit

Zehnder ComfoAir 550. Ventilation unit Use The ventilation unit was specially developed for use in residential and commercial buildings with high ventilation demand. It combines maximum comfort, simple operation and high efficiency with flexible

More information

THE NEW DIMENSION OF AIR CONDITIONING

THE NEW DIMENSION OF AIR CONDITIONING THE NEW DIMENSION OF AIR CONDITIONING Ceiling products controlled by Vari PRO TM NETWORK SERVER CHILLER CEILING PRODUCTS A PLEASANT INDOOR CLIMATE; ENERGY EFFICIENCY AND WITH LOW SOUND LEVEL Chiller Oy

More information

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development INTRODUCTION Heat Pipe Technology, Inc. Heat Pipe Technology, Inc. (HPT) was founded in 1983. With funding from private investors, and a grant from the Department of Energy. HPT began research on a new

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Saving Energy and the Environment with the latest developments in Heat Pipe Technology

Saving Energy and the Environment with the latest developments in Heat Pipe Technology Continuing Professional Development (CPD) Saving Energy and the Environment with the latest developments in Heat Pipe Technology CIBSE Approved CONTENTS What is a Heat Pipe Heat Pipes for Energy Recovery

More information

High Efficiency Dehumidification System (HEDS)

High Efficiency Dehumidification System (HEDS) Advanced HVAC Technologies High Efficiency Dehumidification System (HEDS) Scot Duncan, P.E., Jim Meacham, P.E. Conservant Systems, Inc. August 16, 2017 Tampa Convention Center Tampa, Florida Why Was HEDS

More information

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS Super Radiator Coils Super Radiator Coils is a company where employees are valued, heat transfer problems are solved, and exceptional customer service

More information

Technical Information HXV - HRV Ventilation

Technical Information HXV - HRV Ventilation Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General

More information

Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W: T:

Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W:   T: Eco Active H Y B R I D U N I T W: www.gdl.co.uk T: 01457 861538 Eco Active Hybrid Unit The Eco Active Hybrid unit is designed to provide ventilation in both summer and winter seasons. Ventilation is achieved

More information

SAVE VTC 700. Heat Recovery Ventilation Unit

SAVE VTC 700. Heat Recovery Ventilation Unit Heat Recovery Ventilation Unit 207581-EN_GB 23-08-2011V.A001 Contents 1 Warnings... 1 2 Introduction... 2 3 Interface description... 3 3.1 Control panel... 3 3.2 Display symbols... 4 4 Menu settings...

More information

AIR HANDLING THERMAL CONDITIONS

AIR HANDLING THERMAL CONDITIONS AIR HANDLING THERMAL CONDITIONS Parts of air handling unit (=AHU): Outdoor air grille Air chamber Outdoor air damper Filter Heat recovery unit Heating coil Fan Sound absorber Mixing chamber Per-heating

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

Oilon Ground Source Heat Pumps

Oilon Ground Source Heat Pumps Oilon Ground Source Heat Pumps Homes - Large properties - Industry Ground source heat pump Oilon CUBE For properties 90-400 m² Extremely high domestic hot water production The Oilon CUBE ground source

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information