Pumps Motors ISO 9001 Company

Size: px
Start display at page:

Download "Pumps Motors ISO 9001 Company"

Transcription

1 DT OOKLET Hz Pumps Motors ISO ompany Pumping Solution

2 ontents Product data Introduction pplications Features and benefits Type key Operating conditions Other versions on request Function LE ontroller for to pumps LE V ontroller for to pumps Pump Motor Shaft seal Performance range onstruction onstruction Dimensions and weights Flange dimensions System components Materials LR, LRI, LRN,,,, and Materials LR, LRN,, and Installation Mechanical installation Electrical installation Performance curves LR LR LR LR LR LR LR LR LR LR Dimensions and weights ooster set with pump ooster set with pump ooster set with pump Diaphragm tank Diaphragm tank selection

3 Product data Introduction Lubi booster sets consist of to identical vertical multistage (LR) pumps mounted in parallel on a common base frame, control cabinet with motor protection and integrated LE series controller. These pumps are automatically operated according to system requirement by means of pressure switches (one for each pump). The setting of the pressure switches have to be within the optimal performance area of each pump model. utomatic operation of one or more pumps with VFD control is optional. booster sets are supplied as complete, preassembled and tested systems including suction and discharge manifolds, isolating valves, nonreturn valves, pressure gauge and pressure switches. To ensure stable operation the booster set must be fitted with a suitable diaphragm tank. To select the size of the diaphragm tank see section Diaphragm tank selection at page. pplications Lubi booster sets are designed for the transfer and pressure boosting of clean water for community water supply, apartment complex, hotels, hospitals, industries, commercial buildings, schools, etc. Features and benefits The stateoftheart features introduced into this new vertical multistage pump generation offer the following benefits: High efficiency Low NPSH ir handling Spacer coupling Sleeve sealing Minimized energy cost Improves suction capability Reduces risk of dryrunning llows easy disassembly of motor from pump (for kw motor onwards) Provides high resistance to pressure pulses and withstands temperature fluctuations as well as external forces nd/or Tungsten carbide bearings Reinforced shaft lock ring Wear resistance, improved dryrunning capability and handling of thermal shocks enable longer operating time Strong axial locking force and high torque lock system enable robust and reliable operation of rotating assembly LE Type key Example Type G SS LR x V /G : See System components /L : See System components /N : See System components Pump Pressure switch NonReturn valve Pressure gauge Isolating valve SS: Onoff control VF : VFD control for pump VF : VFD control for pumps VF : VFD control for pumps VF : VFD control for pumps Number of pumps Pump type Fig. pressure boosting system Voltage/frequency Nonreturn valves can be fitted on the suction side on request.

4 Product data Operating conditions The maximum suction lift (H) can be calculated as follows: H =. m NPSH of the pump other suction losses a safety margin of. metres. Maximum inlet pressure Power range DOL starting SD starting Power supply : : : : Flow range Operating pressure Liquid temperature mbient temperature Maximum suction lift (H): Other versions on request The following versions are available on request: ooster set with jokey pump ooster set with LRI,,,,, pumps Different material combination see chapter System components Singlephase power supply: x V, Hz Threephase power supply: x V, Hz Starting configuration other than standard Hz. Function When a tap is opened, water is taken from the diaphragm tank. Then the pressure drops to the first cutin pressure, and the first pump is cut in. s the consumption rises, more pumps will be cut in until the performance of the pumps in operation corresponds to the requirement. When the water consumption falls, the discharge pressure rises to the cutout pressure and the LE ontroller cuts out one pump. s the consumption falls, more pumps will be cut out. Please see fig. which explains how the pumps will operate based on consumption of water. Example: with pumps utin utout H Pr Pr Pr Pr Pr Pr One pump in operation : : : : : Up to m³/h max. bar to + to +. bar Up to kw per pump Up to. kw to kw x V, Hz. Two pumps in operation Three pumps in operation Fig. Operation with cutin and cutout ascade Step ΔPressure Q LE ontroller for to pumps The Lubi LE ontroller supervises a given number of mainsoperated pumps. The LE ontroller offers the following features/functions: ttractive control box with a dust proof & water proof IP protection & lockable key. ascade control, only the required number of pumps are in operation at any time. Highly reliable magnetic motor contactors. Single phase prevention & overload motor protection. Dry run protection & low pressure protection. Delay & minimum run timers to eliminate unnecessary pump cycle. Manual operation. Pump ON & pump Fault indication. utomatic alternation (changeover) of lead pump to ensure equal run time of all pumps. t the heart of the controller is a PL controller with. olour Touch Screen Display (HMI) to programme the system as per the customer site requirement. LE V ontroller for to pumps LE V ontroller is a premium series state of the art controller which offers all the features mentioned above of LE ontroller. This controller is additionally equipped with a Variable Frequency Drive (VFD) for customer required quantity of pumps. Following are the additional features with VFD ontroller. pressure transducer connected on the discharge manifold, provides a continuous feedback to the VFD to either increase or decrease the speed of the pump, to provide constant pressure during varying flow condition. These means that when demand for water reduces, the pump speed reduces which in turn reduces energy consumption. These feature provides the benefit of lower energy consumption to the customer. The Variable Frequency Drive also provides a smooth, ramp up of speed when the pump motor is started. These drastically reduces the starting current requirement for the pump motor. It also reduces wear and tear on motor bearings & pump rotating components. LE V ontroller also provides a special feature which is called Zero Flow/Demand to avoid unnecessary running of pump motor at very low speeds. Whenever there is no demand of water there is a small leakage loss thru faucets which is detected by the controller and it shuts down the pump motor to save energy. When the pump motor is shut down the leakage losses as mentioned above are supplied by the water from the hydro pneumatic tank. Once the pressure in hydro pneumatic tank falls below a preset condition, the controller will start one of the pump shortly to boost up the pressure in the hydro pneumatic tank. When the usage of water increases, again the controller will detect this and will start operating in a normal condition.

5 Product data Motor Pump head Outer sleeve Tiebolts ase Impellers Fig. LE V ontroller display for to pumps Protection pressure switch or a level switch at the suction side can be used as dryrunning protection. When the water level or pressure has been restored, automatic or manual resetting is possible. Time control To adapt the booster set operation to the actual conditions, the following settings can be made with the touch screen display: Startup delay : Prevents simultaneous startup of all pumps. Stop delay : Prevents simultaneous stop of all pumps. fterrun delay: Keeps pumps in operation for few seconds, after cutout pressure is reached. Time control is particularly convenient to reduce the number of starts and stops per hour, to prevent water hammer and negative pressure in the suction manifold as well as other problems that can arise under certain conditions. Pump The LR pumps are nonselfpriming, vertical multistage centrifugal pumps. The pump consists of a base and a pump head. The chamber stack and the outer sleeve are secured between the pump head and the base by means of tiebolts. The base has suction and discharge connections on the same level (inline). ll pumps are equipped with a maintenancefree mechanical shaft seal. Fig. LR pump Motor These pumps are fitted with a totally enclosed, fancooled, pole motor with principal dimensions in accordance with the EN/IE and DIN standards. Electrical tolerances according to EN /IE. Electrical data Mounting designation Insulation class Efficiency class Enclosure class Supply voltage (Tolerance: ±%) Supply frequency Up to kw: V From. kw: V F EFF IP For P :. to kw x / V For P : to kw x V Hz Motor protection ll motors are protected by the control panel of the booster set. Threephase motors from kw upwards have a builtin thermistor (PT) according to DIN. Singlephase motors have a built in thermal overload switch. Shaft seal s standard the LR pump is fitted with a QV shaft seal (ellow type). Shaft seal QV Description Oring (ellow), arbon/si, FKM Max. Temperature range [ ] to +

6 Product data Performance range Q (USgpm) Hz ISO nnex LR LR LR LR LR LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

7 DELT onstruction onstruction is built up on a common base frame. The pumps are fixed to the base frame by means of bolts. The control cabinets are divided into three groups based on construction. Systems with the control cabinet mounted on the pump base frame. Systems with the control cabinet mounted on a separate base frame. Systems with the control cabinet without a base frame, therefore suitable for floor mounting. For further information, see the paragraph Dimensions. discharge manifold is mounted on the discharge side of the pumps. n isolating valve and nonreturn valve are mounted between the discharge manifold and the individual pumps. The nonreturn valve may be mounted on the suction side on request. suction manifold is mounted on the suction side of the pumps. n isolating valve is mounted between the suction manifold and the individual pumps. Dimensions and weights Dimensions and weights for are stated on pages to. Please note that the dimensions stated may very ± mm and that all systems are supplied without vibration dampers. The dimensions may vary according to the technological improvements of the components and/or materials used. Flange dimensions PN flanges D D D S Standard: EN PN (. Mpa) Nominal diameter (DN) DN D D D S x x x x xx System components Fig. System components Pos. Description Qty. Versions G L N ontrol panel Metal, painted Metal, painted Metal, painted Panel stand Galvanized steel Galvanized steel. (ISI ) Suction manifold Galvanized steel. (ISI ). (ISI ) Isolating valve per rass Nir plated rass Nir plated. (ISI ) pump or cast iron or cast iron and cast iron ase frame Galvanized steel/painted Galvanized steel/painted. (ISI ) Nonreturn valve per rass Nir plated rass Nir plated. (ISI ) pump or cast iron or cast iron Discharge manifold Galvanized steel. (ISI ). (ISI ) Pump LR LRI LRN Diaphragm tank s per customer requirement

8 onstruction Materials LR, LRI, LRN,,,, and LR LRI, LRN Designation Materials EN/DIN ISI/STM EN/DIN ISI/STM Pump head ast iron ENGJL ENJL STM ENJL STM Pump head cover Stainless steel. F M eq. to ISI Shaft Stainless steel. ISI ISI.. ISI ISI Impeller Stainless steel. ISI. (LRI). (LRN) ISI (LRI) ISI (LRN) hamber Stainless steel. ISI. (LRI). (LRN) ISI (LRI) ISI (LRN) Outer sleeve Stainless steel. ISI. (LRI). (LRN) ISI (LRI) ISI (LRN) Oring for outer sleeve EPDM or FKM ase ast iron ENGJL (LR)/ Stainless steel (LRI/LRN) ENJL STM. F M eq. to ISI Neck ring PTFE Rubber parts EPDM or FKM Materials LR, LRN,, and Designation Materials EN/DIN LR ISI/STM EN/DIN LRN ISI/STM Pump head ast iron ENGJS (LR)/ Stainless steel (LRN) ENJS STM. F M eq. to ISI Motor stool ast iron ENGJL ENJL STM ENJL STM Shaft Stainless steel. ISI. Impeller Stainless steel. ISI. ISI hamber Stainless steel. ISI. ISI Outer sleeve Stainless steel. ISI. ISI Oring for outer sleeve EPDM or FKM ase ast iron ENGJS (LR)/ Stainless steel (LRN) ENJS STM. F M eq. to ISI Neck ring arbongraphite filled PTFE earing ring ronze ottom bearing ring T/T Rubber parts EPDM or FKM

9 Installation Mechanical installation Location The booster system must be installed in a wellventilated room to ensure sufficient cooling of the control cabinet and pumps. Note: is not designed for outdoor installation and must not be exposed to direct sunlight. The booster system should be placed with a metre clearance in front and on the two sides for inspection and removal. Pipework rrows on the pump base show the direction of flow of water through the pump. The pipework connected to the booster system must be of adequate size. The pipes are connected to the manifolds of the booster system. To optimize operation and minimize noise and vibration, it may be necessary to consider vibration dampening of the booster system. Noise and vibration are generated by the rotations in the motor and pump and by the flow in pipework and fittings. The effect on the environment is subjective and depends on correct installation and the state of the remaining system. If booster systems are installed in blocks of flats or the first consumer on the line is close to the booster system, it is advisable to fit expansion joints on the suction and discharge pipes to prevent vibration being transmitted through the pipework. Pos. Description Expansion joint Pipe support Vibration damper Note: Expansion joints, pipe supports and vibration dampers shown in the fig. are not supplied with a standard booster system. ll nuts should be tightened prior to startup. The pipes must be fastened to parts of the building to ensure that they cannot move or be twisted. Foundation The booster system should be positioned on an even and solid surface, such as a concrete floor or foundation. If the booster system is not fitted with vibration dampers, it must be bolted to the floor or foundation. Note: s a rule of thumb, the weight of a concrete foundation should be. x the weight of the booster system. Dampening To prevent the transmission of vibrations to building, it is advisable to isolate the booster system foundation from building parts by mean of vibration dampers. Which is the right damper varies from installation to installation, and a wrong damper may increase the vibration level. Vibration dampers should therefore be sized by the supplier. If the booster system is installed on a base frame with vibration dampers, expansion joints should always be fitted on the manifolds. This is important to prevent the booster system from hanging in the pipework. Electrical installation The electrical installation should be carried out by an authorized person in accordance with local regulations. The electrical installation of the booster set must be carried out in accordance with enclosure class IP. Make sure that the booster set is suitable for the electricity supply to which it is connected. Make sure that the wire crosssection corresponds to the specifications in the wiring diagram. Note: The mains connection should be carried out as shown in the wiring diagram. Fig. Schematic view of hydraulic installation

10 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

11 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

12 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

13 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

14 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

15 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR Q (m /h) Q (l/sec) Q ( l/min )

16 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

17 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

18 Performance curves Q (USgpm) with LR LR Hz ISO nnex LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

19 Performance curves with LR Q (USgpm) LR Hz ISO nnex LR LR LR LR LR Q (m /h) Q (l/sec) Q (l/min)

20 Dimensions & weights pumps ooster set with pump H HQ DELT L Fig. Dimensional sketch of a booster set with a control cabinet centred the base plate H HQ DELT L Fig. booster set with a control cabinet mounted on the same base plate as the pumps H HQ DELT L LQ Fig. booster set with a control cabinet mounted on a separate base plate

21 Dimensions & weights ooster set with pump Pump type LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR Supply voltage [V] xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv Motor [kw] Manifold connection R R R R R R R R R R R R R R R R R R R R R R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN L LQ Design : booster set with a control cabinet mounted on the same base plate as the pumps. Design : booster set with a control cabinet centred on the base plate. Design : booster set with a floormounted control cabinet. Design D: booster set with a control cabinet mounted on a separate base plate. Dimensions may vary by ± mm. pumps H HQ Weight [kg] Design

22 Dimensions & weights pumps ooster set with pump H HQ DELT L Fig. booster set with a control cabinet mounted on the same base plate as the pumps H HQ DELT L Fig. booster set with a control cabinet mounted on the same base plate as the pumps H HQ DELT L LQ Fig. booster set with a control cabinet mounted on a separate base plate

23 Dimensions & weights pumps ooster set with pump Pump type Supply voltage [V] Motor [kw] Manifold connection L LQ H HQ Weight [kg] Design LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv R R R R R R R R R R R R R R R R R R R R R R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN Design : booster set with a control cabinet mounted on the same base plate as the pumps. Design : booster set with a control cabinet centred on the base plate. Design : booster set with a floormounted control cabinet. Design D: booster set with a control cabinet mounted on a separate base plate. Dimensions may vary by ± mm.

24 Dimensions & weights pumps ooster set with pump H HQ DELT L Fig. booster set with a control cabinet mounted on the same base plate as the pumps H HQ DELT L LQ Fig. booster set with a control cabinet mounted on a separate base plate H HQ DELT L LQ Fig. booster set with a floormounted control cabinet

25 Dimensions & weights ooster set with pump Pump type LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR LR Supply voltage [V] xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv xv Motor [kw] Manifold connection R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" R ½" DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN L LQ Design : booster set with a control cabinet mounted on the same base plate as the pumps. Design : booster set with a control cabinet centred on the base plate. Design : booster set with a floormounted control cabinet. Design D: booster set with a control cabinet mounted on a separate base plate. Dimensions may vary by ± mm. pumps H HQ Weight [kg] Design

26 Diaphragm tank Diaphragm tank selection To ensure stable operation, the booster set must be installed in combination with an adequate diaphragm tank. The size of the obligatory diaphragm tank can be calculated by means of the following formula: Q x x ( + (utin) + Δp) V = x x n max x Δp V = Tank volume [litres] Q = Mean flow [m³/h] Δp = Difference between cutin and cutout pressure utin = utin pressure (lowest) [bar] k = onstant for diaphragm tank precharge pressure: k =. nmax = Max. numbers of starts/stops per hour The diaphragm tank precharge pressure is set to. times the lowest cutin pressure. k The diaphragm tank may also be selected on the basis of the below tables in which the following values have been used: Motors up to and including. kw: Motors above. kw: Diff. between cutin and cutout: n = to n = to Δp =. [bar] Lubi pumps and motors are not subject to any particular limitations as they are tested up to start/stops per hour. However when dimensioning the diaphragm tank volume the following parameters may also be considered: Maximum number of start/stops per hour allowed by local regulations Maximum number of start/stops per hour described by the system designer Temperature and ventilation conditions vailable space for diaphragm tank installation. Minimum diaphragm tank volume [litres] at Δp =. [bar] and n max = : Pump type utin [bar] utin [bar] Minimum diaphragm tank volume [litres] utin [bar] utin [bar] utin [bar] utin [bar] utin [bar] utin [bar] LR LR LR LR LR LR LR LR LR LR Minimum diaphragm tank volume [litres] at Δp =. [bar] and n max = : Pump type utin [bar] utin [bar] Minimum diaphragm tank volume [litres] utin [bar] utin [bar] utin [bar] utin [bar] utin [bar] utin [bar] LR LR LR LR LR LR LR LR LR LR Note: Refer to the cutin pressure closest to the lowest setting of the selected booster set.

27 NOTE

28 Lubi Submersibles Limited. +, +, + Joppa House next to lma Hotel, Kitengela along NamangaNairobi Sales Enquiries: info@damwotechengineering.com, sales@damwotechengineering.com Product Improvement is a continuous process at LUI. The data given in this publication is therefore subject to revision.

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html

More information

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html

More information

TP /4-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html

More information

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html

More information

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html

More information

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html

More information

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html

More information

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html

More information

CR20-07 A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html

More information

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html

More information

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz GRUNDFOS DATA BOOKLET Centrifugal machine tool pumps 5/6 Hz Contents General description Introduction 3 Applications 3 Special features 3 Identification Type key Codes Pump types and data Construction

More information

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800 KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal

More information

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Introduction Wash & Clean systems for the food processing industry is an utility application that sets high requirements

More information

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution Submersible Pumps Motors 50Hz 2 Submersible Pump Pumping Solution 65 Product data 2 Submersible bore well pumps Construction Submersible motor & pumps for deep wells of 2 (DN 300 mm). Sized for connection

More information

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

6800 Design Envelope Booster. Technical overview

6800 Design Envelope Booster. Technical overview 6800 Design Envelope Technical File No: 100.30in Date: may 26, 2014 Supersedes: 100.30in Date: march 17, 2014 contents 1. Product introduction 4 Summary 4 Background 4 Benefits 4 2. Product data 5 Nomenclature

More information

CombiBloc Close-coupled centrifugal pumps

CombiBloc Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide 1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5 5 . Manual Contents Warranty Details page 2 Pump Description & Technical page 3 Specifications Transportation, Storage & Installation page 4 Pump Maintenance page 5 Wet end Dismantling page 6 Wet end Assembly

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Company name: Created by: Phone:

Company name: Created by: Phone: Position Qty. Description 1 SL1..1.55..6G.C Product o.: 9655 ote! Product picture may differ from actual product on-self-priming, single-stage, centrifugal pump designed for handling wastewater, process

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy

More information

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED DNJ SERIES PUMPS END SUCTION CLOSE COUPLED DNJ SERIES PUMPS These are close coupled with standard JM solids shaft ball bearing motors specially designed for pump applications in accordance with standards

More information

MARLOW PUMPS RECIRCULATION

MARLOW PUMPS RECIRCULATION End suction centrifugal pump line available in both close coupled and frame mounted configurations allow users to meet exactly most flow conditions on commercial pool and waterpark applications. Features

More information

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 Combi Modular System Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 SPX FLOW Johnson Pump brand water, chemical and petrochemical standardised pumps represent a range of centrifugal pumps

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

ECONOBOOST EB II & EB III Compact Water Booster

ECONOBOOST EB II & EB III Compact Water Booster ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest

More information

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s PAPANTONATOS P u m p s s e r v ic e & e n g i nee r in g We supply clean water and remove waste water s e w a g e p u m p s submersible pumps The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45

More information

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256) CombiChem Centrifugal pumps according to ISO 5199 and ISO 2858 / EN 22858 (DIN 225) CombiChem No limits to reliability! CombiChem is Johnson Pump s solution for liquid transport in the chemical industry.

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION pumps are Hi-Tech single stage, horizontal centrifugal pumps with magnetic driven coupling. In compact and silent close-coupled execution, they can be mounted on to B5 frame motors.

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

dualarm Vertical In-Line Pumps

dualarm Vertical In-Line Pumps Series 430 & 438 dualarm Vertical In-Line Pumps FILE NO: 43d.1 DATE: Jan. 0, 010 SUPERSEDES: 43d.1 DATE: Sept., 008 Series 430 & 438 Smart pumps for the commercial HVAC market. Armstrong Vertical In-Line

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

Lenntech. Tel Fax bar. Multistage Pumps.

Lenntech. Tel Fax bar. Multistage Pumps. Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 100 bar Multistage Pumps Vogel Series MPE Technical Data Performance Range: m Capacity up to 300m 3 /h (1320USgpm)

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although

More information

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256) CombiChem Centrifugal pumps according to ISO 199 and ISO 88 / EN 88 (DIN 46) The SPX Johnson Pump Combi system is a modular programme of single stage CombiChem No limits to reliability! centrifugal pumps

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Other languages www.grundfos.com/cu300-manual

More information

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm HEGA Horizontal Multistage Pump Brief Introduction HEGAHorizontal Multistage Pump is the new multistage product series, the excellent hydraulic performance and structure of which have enabled low cost

More information

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1 Centrifugal Pump Single Shaft Seal 2 Freephone lines are open between 8.00am and 5.30pm Monday to Friday FREEFAX: 0800 801404 TETRA PAK PUMPS Centrifugal Pump Single Shaft Seal Motors: 3000 r/min, 3-phase

More information

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps Series 0 & FILE NO: d. DATE: June, 00 SUPERSEDES: d. DATE: July, 00 dualarm Vertical In-Line Pumps dualarm Smart pumps for the commercial HVAC market Vertical In-Line pump, the best design for HVAC systems,

More information

Vertical Multistage. HP Phase Voltage Amps

Vertical Multistage. HP Phase Voltage Amps Models UWH thru UWH, UWJ0 thru UWJ and UWK0 Stainless Steel Models UWK thru UWK and UWL0 thru UWL Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions

More information

Chemical Pumps Vertical Chemical Pump Type TNP

Chemical Pumps Vertical Chemical Pump Type TNP Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis

More information

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified

More information

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM Vogel Pumpen Vogel - Blockpumps Design LMN / LM 1 Materials: Design LMN, Sizes DN 32-80 Design LM, Sizes DN 100-150 Performance: Capacity up to 500 m 3 /h (2200 USgpm) Head up to 95 m (312 feet) Speed

More information

GRUNDFOS PRODUCT GUIDE. Domestic Water Supply Family

GRUNDFOS PRODUCT GUIDE. Domestic Water Supply Family GRUNDFOS PRODUCT GUIDE Domestic Water Supply Family DWS Product Guide 8-09.indd 1 8/18/2009 2:32:25 PM Domestic Water Supply Family Table of Contents Handbook Applications Page No. Constant pressure...

More information

KUBOTA Double suction volute pump

KUBOTA Double suction volute pump PUMPS CATALOGUE KUBOTA Double suction volute pump DV-L type J series KUBOTA Corporation DOMESTIC OFFICES AND OVERSEAS OFFICE E-Mail:pump@kubota.co.jp http://www.kubota.co.jp/english KUBOTA Double suction

More information

CombiBloc. Close-coupled centrifugal pumps

CombiBloc. Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of SPX FLOW 's Johnson Pump brand Combi-system,

More information

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Grinder Pumps KGP(X) 7.5-15HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) (PENDING) The KEEN PUMP KGP(X) series centrifugal grinder pumps are designed for municipal, commercial

More information

INSTRUCTION AND REPAIR MANUAL

INSTRUCTION AND REPAIR MANUAL SECTION 6 ITEM 390 DATED JANUARY 2003 SUPERSEDES SECTION 6 ITEM 390 DATED OCTOBER 2000 INSTRUCTION AND REPAIR MANUAL SERIES 390 6 The 390 Series is a superior commercial Multi-Stage Vertical In-Line Centrifugal

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

Wilo IL Vertical Split-Coupled Inline Pumps

Wilo IL Vertical Split-Coupled Inline Pumps Wilo IL Vertical Split-Coupled Inline Pumps Vertical Inline Split-Coupled, Single Stage Pumps March, 2013 Marcos D. Roimicher, Product Manager BS Market Segment, Product Management Department 120-08-002-0313

More information

Pumpco Sdn. Bhd. Solar Water Heater. 1 of 8 MAIN FEATURES OF SOLARMATE

Pumpco Sdn. Bhd. Solar Water Heater. 1 of 8 MAIN FEATURES OF SOLARMATE Pumpco Sdn. Bhd. Solar Water Heater Solar Water SOLARMATE MAIN FEATURES OF SOLARMATE SOLAR WATER TANKFlat base shaped storage tank ideal for inclined roof with 0.5mm thick aluminium base plate.1.2mm thick

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

KTZ KTD DEWATERING PUMPS

KTZ KTD DEWATERING PUMPS www.tsurumi-global.com KTZ KT EWTERING PUMPS Submersible eavy-duty ewatering Pumps The KTZ-series is Tsurumi s flagship line of submersible pumps. Made with a cast iron body and high chromium cast iron

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges TM High Performance in Wastewater Pumping HOMA submersible water and wastewater pumps operate worldwide in numerous domestic, municipal

More information

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials The SSA series is an All-in-One self-priming silent booster pump, the compact design combined pressure tank, pressure switch, flow switch and full protection controller, moreover, the evolutional flow

More information

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091 A Series ISO-9 orizontal Multistage Centrifugal Pumps AC/AI, ABI/ABS z APEC Pump ENTERPRISE CORP. 3F.,No.39,Sec. Mingzhi Rd., Taishan Dist.,New Taipei City 3,Taiwan. Tel : +--937 Fax: +--97 www.apecpump.com

More information

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd 1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk

More information

GRUNDFOS PRODUCT GUIDE. Domestic Water Supply Family

GRUNDFOS PRODUCT GUIDE. Domestic Water Supply Family GRUNDFOS PRODUCT GUIDE Domestic Water Supply Family Domestic Water Supply Family Table of Contents Handbook Applications Page No. Constant pressure... 5 Flow based pressure boosting... 5 Suction lift...6

More information

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Design LR, LMR Technical Data Performance: m Capacity up to 350m 3 /h (1540USgpm)

More information

Pumps SELECTION OF A PUMP

Pumps SELECTION OF A PUMP Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION The renewed ETN-Lined pumps are singlestage, magnetic driven, centrifugal pumps in closecoupled execution. ETN-Lined pumps are available both inpp+gf and ETFE. The pump casing is

More information

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve seal Bearing Enclosed Gland packing Sleeve bearing (Lubricant oil) Water cooling jacket Bearing, Stuffing box (81-120 C) seal: External flushing PUMP Suction side JIS10K normal type Discharge side JIS10K

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

EVMSU - Vertical Multistage Pumps. Product Catalog

EVMSU - Vertical Multistage Pumps. Product Catalog EVMSU - Vertical Multistage Pumps Product Catalog www.pumpsebara.com Built like a Kata a A Katana is a traditional Japanese sword made with distinctive, longstanding expertise started in 300 A.D. Katana

More information

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

MCV - MCH - MCHZ Multistage pumps

MCV - MCH - MCHZ Multistage pumps MCV - MCH - MCHZ Multistage pumps You can put pressure on them! We offer you a range of reliable high-pressure multistage pumps. It includes a series of horizontal pumps, MCH and a series of vertical pumps,

More information

HOMA Pump, Ansonia Connecticut

HOMA Pump, Ansonia Connecticut TM High Performance in HOMA began as a submersible motor manufacturer more than fifty years ago. We expanded into full pump production in the 1960s. Every product we design and manufacture has always exceeded

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

HAL Hercules Horizontal Pumping System STRONG. VERSATILE. EFFICIENT.

HAL Hercules Horizontal Pumping System STRONG. VERSATILE. EFFICIENT. HAL122140 Hercules Horizontal Pumping System STRONG. VERSATILE. EFFICIENT. Hercules Horizontal Pumping System VERSATILE HORIZONTAL SURFACE PUMPING SYSTEM FOR CONVENTIONAL OR UNCONVENTIONAL PLAYS Summit

More information

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System DualPak Series 6900 FILE NO: 62.11 DATE: Feb. 15, 1999 SUPERSEDES: 62.11 DATE: Sept. 28, 1995 DualPak 6900 Series Booster System D U A L P A K 6 9 0 0 Armstrong proudly presents the Series 6900 DualPak

More information

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage. LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal

More information

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0) Volute Casing Pumps Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0)31 721 52 24 FR: +41 (0)21 905 10 80 Technical Data Performance: m Capacity up to 600m 3 /h (2640USgpm) m Head up to 100m (330feet)

More information

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C MADE IN ITALY DATA SHEET Horizontal Two Stage Centrifugal Pumps 2CP 20 2CP 32/20A 00 2CP 32/20B 80 2CP 32/200B HEAD [m] 60 2CP 32/200C 40 20 0 2 4 6 8 0 2 4 6 3 FLOW [m /hr] Linz Electric is a brand of

More information

PENGUIN SERIES HSC PUMPS INTRODUCTION

PENGUIN SERIES HSC PUMPS INTRODUCTION PENGUIN Installation & Maintenance SERIES HSC PUMPS MODELS HSC-1/4 HSC-1/2 HSC-3/4 HSC-1 HSC-2 HSC-3 SEALS S - Single D - Double M - Single/Multi-Stage INTRODUCTION Penguin 316 stainless steel centrifugal

More information

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CAP SERIES SEWAGE AND WASTE WATER PUMPS Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and

More information

KTZ KTD DEWATERING PUMPS

KTZ KTD DEWATERING PUMPS www.tsurumi-global.com KTZ KT EWTERING PUMPS Submersible eavy-duty ewatering Pumps The KTZ-series is Tsurumi s flagship line of submersible pumps. Made with a cast iron body and high chromium cast iron

More information

This label warns for risk of electrical shock when failing to observe.

This label warns for risk of electrical shock when failing to observe. MANUAL horizontal centrifugal pumps MB series ic drive SB series mechanical seal 1. Introduction 2. Safety precautions 3. Receipt 4. Installation / Operation and Maintenance 4.1 Installation 4.2 Operation

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

W+ Series SANITARY CENTRIFUGAL PUMPS

W+ Series SANITARY CENTRIFUGAL PUMPS W+ Series SANITARY CENTRIFUGAL PUMPS SPX FLOW is a leading innovator of solutions with decades of experience in centrifugal pump design, covering premium brands such as APV and Waukesha Cherry- Burrell.

More information

Pressure Boosting Solutions

Pressure Boosting Solutions GRUNDFOS Water Pressure Boosting Pressure Boosting Solutions 1 GRUNDFOS Water Pressure Boosting WHAT CAN CAUSE LOW WATER PRESSURE? Poor mains pressure Generally due to water companies reducing the supply

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps Water Circulation Pumps & Circulators GT Series Single-Stage, Double Suction Horizontal Split Case Pumps GT Series Pumps provide the ultimate in reliability and ease of installation for heating, air conditioning,

More information