1 Climate from the Ceiling Handbook 2015

2 C O O L I N G S Y S T E M S 2 Table of Contents Approval and registration 3 General surface ing and heating 4 7 Joining technology FiX push connection 8 Joining technology press connection 9 Joining technology protec push connection 10 Joining technology screw connection 11 Assembly instructions Assembly instructions FiX push connection 12 5 seconds of processing for your safety 13 Assembly instructions press connection Assembly instructions protec push connection FiX KC3A FiX KC3A set-up 18 KC3A technical data 19 FiX KC4A set-up 20 KC4A technical data 21 KC3A and KC4A assembly instructions KC3A and KC4A installation instructions FiX KC90B FiX KC90B set-up 26 KC90B technical data 27 KC90B assembly instructions KC90B installation instructions 31 FiX KCLC1 FiX KCLC1 set-up 32 KCLC1 technical data 33 KCLC1 assembly instructions FiX KC75W FiX KC75W set-up 36 KC75W technical data 37 KC75W assembly instructions The ceiling ing FiX sizing 40 Important system components 41 Control for FiX systems 42 Positioning of the dew point sensors 43 Hydraulic connection diagrams for ing ceilings Filling, pressure test and pressure test log Important assembly and installation instructions Product range Representative offices and headquarters 66 67

3 Quality targets of KE KELIT Approval Registration 1. Our quality targets go beyond the quality of the products and encompass all areas that are required in DIN ISO An order-accompanying quality assurance system is already intended to guarantee the prevention of errors by integrating suppliers and customers. 3. Every employee is responsible for the quality of his own work. A high level of motivation forms the basis for constant selfchecking. Fire protection test for KC4A in accordance with: ÖNORM EN Classification according to Fire protection test for KC90B in accordance with: ÖNORM EN and ÖNORM EN Classification according to ÖNORM EN We regard the fulfilment of specific market requirements and customer requirements as a precondition for the utmost customer satisfaction. 5. Responsibility for the environment now and in the future gives us the motivation to manufacture, long-lasting products in environmentally compatible processes. Certified Quality Assurance System ÖNORM EN ISO 9001:2000 Reg. No. 366/0 Senator Karl Egger eh. Managing Director 3

4 C O O L I N G S Y S T E M S Surface ing and heating The long-term prospects for our way of life depend on whether we succeed in reducing energy consumption and increasing the use of renewable energy sources. Heating and ing systems consume the majority of a building's energy. Up to 45% of a family's budget is used for the costs of energy consumption for this purpose. Long-term plans are therefore aimed at: l Saving costs l Energy efficiency l Use of renewable energies General solution approaches Full heat protection for all buildings during the course of construction or renovation Advantage Reduced heat loss, increased energy efficiency Reduced costs Disadvantage Highly insulated, heat-dense rooms can become physiologically uncomfortable Surface ing and heating with a high share of radiation Heat transfer Heat is basically transferred using three different methods l radiation infrared, without any medium l convection natural movement of air, artificial fan l line direct contact Surface cooking and heating systems have the following characteristics Floor heating l mainly radiation l barely any convection l heat transmission to the person Ceiling heating l mainly radiation l barely any convection l no heat transmission to the person Ceiling ing l strong radiation l barely any convection l no ing transmission to the person Wall heating and ing l strong radiation l little convection l no ing transmission to the person Advantage Low-temperature operation, alternative energy source, integration of ing or heating surfaces that are not otherwise used. 4

5 Surface temperature C Advantages When using radiant heating, no fan is required, resulting in the following advantages: l energy saving l no draughts l no noise generation l no servicing l no additional space requirement l no supra-regional air exchange (contamination, dust allergies) too cold too warm Room temperature C Comfort perception Through the addition of internal (computers, people etc.) and external (sun etc.) heat loads, the room temperature becomes higher than the surface temperature of the walls. The state-of-the-art air conditioning technology has the task of ensuring an atmosphere that is perceived by the people working and living in the buildings/rooms as being comfortable and pleasant and NOT keeping buildings and room air at a specific temperature. In detail "Thermal comfort" has a significant influence on well-being and health. Heating l If the human body emits more heat than it can generate, a feeling of cold is created. l The lower the temperature of the components, the higher the room air needs to be heated up in order to attain well-being. l The higher the temperature of the surface components, the lower the air temperature can be held with the same comfort. Cooling l The same effect applies conversely to ing; the air temperature does not need to be ed down as much as with convection ing. General Due to the overriding significance of the radiant share with ceiling ing or heating systems, the desired effect can already be achieved with small temperature differences. Surface temperature Wall surface temperature 20 C Room temperature 26 C 25 C 25 C 5

6 C O O L I N G S Y S T E M S The FiX ing ceiling Many factors, such as thermal radiation, sunlight, room temperature and humidity are necessary for the room climate/a person's comfort Comfort l optimum room climate l fast temperature adaptation l quiet and draught-free operation l optimally adjustable to personal requirements l no uncomfortable hot and cold zones Environmental protection l energy savings compared to conventional systems l use of regenerative energies (low temperature) l reduction of CO 2 emissions l EU Directive: "Energy Performance of Buildings" end: Air temperature SUNLIGHT Thermal radiation Design freedom l no radiators l wall and ceiling ing surfaces are not visible l interior design freedom l flexibility through a combination of heating and ing l area of application in the home, office, schools, hospitals etc. Health l high share of radiant heat, no draughts l no swirling dust l difficult living conditions for bacteria, mould and mites l ideal room climate l balanced temperature gradient in the entire room 6

7 High acceptance with users and investors l increase in performance through optimal temperature conditions l integration into the building Efficiency l lower investment costs compared to separate heating and ing systems l space saved due to the omission of ventilation ducts l low operating costs, l use of "free ing" systems l low servicing costs l quick and easy assembly Comparison of operating costs for buildings with a ing output of 45kW Cooling ceiling with groundwater 45 kw Cooling output for building Primary energy for cold water generation to 16 C Primary energy 0.0 kw 1 kw The soil and groundwater temperatures are approx. 10 C 12 C. These renewable energy sources are excellently suited to geothermal energy generation. With only 1 kw of electric pumping output, up to 45 k" of ing energy can be transferred to the building with the "free ing" operation. Cooling ceiling with chilled water unit kw Cooling output for building Primary energy for cold water generation to 16 C Primary energy 13 kw 1 kw Air conditioning system with fan coil 45 kw Cooling output for building Primary energy for cold water generation to 8 C Primary energy 18 kw 1 kw The flow temperature for ing ceiling is approx.16 C, for fan coils approx. 8 C, so that the primary energy output with fan coil systems increases by up to 35% compared to ing ceiling systems with a chilled water unit. 7

8 C O O L I N G S Y S T E M S The FiX joining technology Requirements for the FiX connection: l connection to the FiX pipe that can be detached with a specialist tool, however the connection to the KELOX module pipe cannot be detached l permanently tight push connection in the FiX area l permanently tight press connection in the KELOX area l easy and quick processing l impervious to oxygen diffusion The solution The push connection for FiX pipe d10mm Implementation For connections of the FiX ing and heating elements The material l high-compression moulded WINDOX-PPSU l WINDOX pressing sleeve made of stainless steel "leak before pressed" l synthetic, ageing-resistant EPDM O-rings. l grab ring made of PP and stainless steel Plastic push-on cap PP holder with integrated stainless steel claws ageing-resistant EPDM O-ring Support sleeve Attention: For all press variants (KELOX or WINDOX-U) 8

9 The KELOX-WINDOX- U joining technology Requirement for the KELOX-WINOX-U pressing l permanently impermeable l sturdy for building site use l compact design l axial connection l halogen-free l impervious to oxygen diffusion l DVGW (W534) approval in the flush-mounted area l "leak before pressed" in the dimensions d16 63mm l pressing U-contour l for sealing the threaded unions, liquid sealants must not be used! The solution The tried-and-tested WINDOX-U press connection for d16-63mm pipes KELOX-FiX press connection for d12mm pipes Implementation For all applications in the surfacemounted and flush-mounted area The material 1 Body made of high-compression moulded WINDOX PPSU 2 One O-ring made of EPDM 3 Special "leak before pressed" profile 4 pressing sleeve made of stainless steel with pressing jaw guide 5 viewing window as insertion control 6 pressing jaw with U-contour use the same U-pressing tools! 6 9

10 C O O L I N G S Y S T E M S The KELOX-protec joining technology: Requirements for the KELOX-protec push connection l permanently impermeable l non-detachable push connection l axial connection l diffusion-tight l DVGW (W534) approval in the flush-mounted area l insertion prevention of noncalibrated pipes The material l stress-free annealed brass with nonporous metal plating or highcompression moulded l push-in sleeve made of polyamide l synthetic, ageing-resistant EPDM O- rings l protector ring made of plastic l protective cap to prevent contamination The solution The tried-and-tested KELOX-PROtec push connection for d16-32 mm pipes Implementation For all applications in the surface-mounted and flushmounted area Set-up 1 Body made of high-quality brass with non-porous metal plating or highcompression moulded PPSU 2 2K-GRAB RING holding components made of glass fibre reinforced polyamide and elastomer 3 Sleeve made of transparent polyamide 4 Two O-rings made of EPDM 5 Protector ring made of highly durable plastic, prevents the insertion of non-calibrated pipes 6 Closed visual inspection window

11 The KELOX joining technology Requirements for the KELOX screw fitting: l axial connection l detachable screw fitting, however, nondetachable pipe connection l prevention of electrochemical dipoles l no contact between medium water and aluminium layer l DVGW (W534) approval in the flushmounted area The solution The multi-sealing KELOX screw fitting for pipes from d14-25mm Implementation For connections to distributors and radiators in the surface-mounted area Set-up 1 Nut made of high-quality brass with non-porous metal plating 2 Metal conical seal 3 Three O-rings made of EPDM 4 Compression sleeve made of high-quality brass with non-porous metal plating 5 Interlocking teeth for the axial connection

12 C O O L I N G S Y S T E M S Easy steps to the tight FiX push connection Only use trained assembly specialists! 1. Cut the FiX pipe to length at right angles with the WZ932 pipe cutter 2. Mark the insertion depth at the end of the pipe using the support sleeve (The insertion depth = the length of the support sleeve up to the flange) 3. Insert support sleeve completely into the end of the pipe, this will ensure that the O-ring is not damaged when being pushed onto the pipe, furthermore, the support sleeve prevents deformation of the pipe. 4. Slide the pipe in straight, as far as it will go into the push connection. The O- rings are lubricated, do NOT use any additional lubricant. A safe and tight connection is achieved if the marking described in Point 2 is still visible on the pipe at the end of the push-on cap. 5. Pull the pipe back slightly to ensure that the clamping ring and thus a correct axial connection has been activated. 12

13 Therefore, invest 5 seconds per pipe connection for your safety 3 sec.: Visual check of each pipe end for a surrounding bevel. This ensures: l The pipe is correctly calibrated l O-rings cannot be moved and damaged. l Pipes can be attached without particularly excessive force. 2 sec.: Visual check of the insertion depth. Marking on the pipe at the screw fitting This ensures: l The subsequent pressing or screw fitting creates the axial connection of the joint to an unlimited extent. l The mount is activated with push fittings, the axial connection is ensured. 0 sec.: Do not allow (wherever possible) any unnecessary time to pass between insertion and pressing/screw fitting. This ensures: l Pressing has not been forgotten l Screw fitting has not been forgotten. l With the push connections, the suitability for use is ensured by complete insertion. Check of the axial connection by pulling back the pipe ends. "inserted = tight"! Pressing grooves visible Marking on the pipe at the push fitting Visual check with the push fitting Visual check with the push fitting 13

14 C O O L I N G S Y S T E M S Assembly instructions KELOX-WINDOX-U KWU - press connection Only use trained assembly specialists! 1.1 Easy steps for a tight KELOX KWU press connection 1. Cut to length Always at right angles - therefore straighten materials supplied in coils beforehand! 1.1 d16 25 with pipe cutter (WZ130) 1.2 d25 63 with pipe cutter (WZ935) 2. Calibrate and chamfer Always turn clockwise, both into and out of the pipe! 2.1 d16 32mm Click the universal handle onto the calibration mandrel (WZ915) and rotate clockwise as far as it will go. This achieves the following: Cutting angle corrected to 90 Inner pipe wall is calibrated Deburred on the outside Surrounding inner bevel at the end of the pipe with a depth of approx. 1 mm visual check! 2.2 d40 63mm Turn in the deburring tool (WZ913) clockwise as far as it will go. This results in: Inside of pipe exactly round Inner bevel at the end of the pipe with a depth of approx. 1mm visual check! 2.3 Slow-running (max. 500 rpm) drills or cordless screwdrivers can alternatively be used. Remove the handle for this The plastic/aluminium chips MUST be removed from the calibration tool/protective cage after each calibration process. 14

15 4. Pushing on the press fitting WITHOUT using excessive force Slide the moulded piece onto the KELOX pipe end. Important: Push the pipe in as far as it will go 4. Check for the correct insertion depth on the viewing windows of the press fittings! Make the press connection immediately after joining the pipe connection! 5. Pressing Fit the KELOX-conform pressing tool with the correctly sized KELOX pressing jaws (U-contour). Press the WINDOX KWU or KC fittings - position pressing jaws in the middle of the pressing sleeve and press. CORRECT! INCORRECT! 5.1 Additional check security "leak before pressed" does not replace the visual check. The design, in conjunction with the special profile geometry, allows the UNpressed fittings to be identified and localised with certainty during the pressure test. - simply press - done! 5.2 The pressing procedure is completed when the pressing jaws are completely closed. After pressing, open the pressing jaws again and lift the pressing tool off of the pressed part. The pressing procedure can only be performed once! 5.3 The same procedure applies if a manual pressing tool (WZ983) is used. For assembly corrections, the joints may be turned by up to one rotation after processing! 5. Unpressed joints are not tight on the basis of the design and can specifically pose a danger with an air pressure test if the pipe and fitting separate. The axial connection will only be created by pressing. Therefore, perform a visual check of ALL joints. 15

16 C O O L I N G S Y S T E M S Our development concept - Your advantages Simple No complex, expensive assembly tools, consistent fitting concept from d16-32 Safe A joint that is NON-detachable, the sealing function takes priority. The fixing takes place with the grab ring on the inside of the pipe Pushing in NON-calibrated pipes is effectively prevented by the protector ring and therefore the O- rings are protected from damage. Correctly processed fittings are non-detachable, permanently sealed joints. The viewing window check makes you certain! Handy Optimised body size for flush-mounted installations without any problems, slim for subsequent insulation. Sturdy Selection of materials in accordance with the latest technology: Brass with non-porous metal plating or high-compression moulded PPSU polyamide, PA- GF, EPDM nano-coated... Suitable for building site use The sealing function is bonded to the calibrated, inspected and clean inside surface of the KELOX pipe. Grease-free EDPM O-rings, no contamination problem, no excessive force required (do not relubricate!) Rotatable and adjustable after assembly. Tested Subjected to extensive testing: pressure surge, temperature change, high pressure, tensile strength... Certified by DVGW and ÖVGW KE KELIT Patent All the relevant components in the fitting are protected by patent. Licences have been granted to renowned European partners 16

17 Assembly instructions for KELOX-protec push fittings 1. Cut to length: Always at right angles - therefore straighten materials supplied in coils beforehand! 1.1 d16 20 with pipe cutter (WZ130) 1.2 d25 63 with pipe cutter (WZ935) 2. Calibrate and chamfer the entire circumference: Always turn clockwise, both into and out of the pipe! d16-32mm Click the universal handle onto the calibration mandrel (WZ915) and rotate clockwise as far as it will go. Alternatively, a slow running drill or power screwdriver can be used (max. 500 rpm). 3. The plastic/aluminium chips MUST be removed from the calibration tool/protective cage after each calibration process. This achieves the following: Cutting angle corrected to 90 Inner pipe wall is calibrated Deburred on the outside Surrounding inner bevel at the end of the pipe with a depth of approx. 1 mm visual check! Ensure that pipes that have already been joined to a fitting at one end do NOT turn when the pipe is being calibrated at the other end! 4. Sliding on the push fitting Push the fitting straight onto the calibrated pipe end, NOT at an angle, as far as it will go. 4.1 A protector ring that is intact prevents pipes that have NOT been calibrated from being pushed into the fitting! This achieves the following: Permanently watertight joint Axial connection made by the patented grab ring Check the insertion depth at the push fitting! For assembly corrections, the joints may be turned by up to one rotation after processing! After the pressure test has been completed and when the system is in operation it should NOT be possible to see the end of the pipe in the viewing window (page 10)! 17

18 C O O L I N G S Y S T E M S FiX KC3A The suspended ceiling The FiX KC3A ceiling heating and ing module for installation in suspended roof structures. The elements are suitable for use in new buildings, as well as for subsequent installation with renovations. Through the customised size adaptation, the modules can be used for all conventional ceiling structures. The use of heat-conducting baffles guarantees an optimum transfer of energy into the ceiling structure, so that even heat/cold distribution within the ceiling is guaranteed and maximum output is reached. FiX KC3A set-up l Module pipe installed in a meandering shape made of PE-RT/Al/PE-RT 12x1.5mm oxygen barrier l Aluminium heat-conducting baffles with omega-shaped beads for holding the module pipe l Special support profiles made of stainless steel, which are connected to the heat-conducting profiles and serve as bracing and for suspending the elements in the sub-structure l The power transfer to the panelling on site is ensured with special pressuremaintaining elements (support profile) l The pipe connection of the heating and ing modules also takes place using radial pressing Advantages l Architectural freedom with ceiling and interior design (seamless plasterboard ceilings, perforated acoustic ceilings, free interior design) l Heating and ing with one system reduces the generation costs l No formation of cracks at the panel joint, as the KC3A heating and ing coils are uncoupled as overlay modules from the plasterboard ceiling/the visible elements of the ceiling l Good heat transfer to the temperature transition plates through extensive heatconducting baffles made of aluminium l Outstanding controllability of the system l Optimal thermal comfort in summer and winter l Clear separation of trades between drywall builder and installer in relation to the assembly and therefore a clear warranty delineation l Good acoustic characteristics through the modular structure Areas of application l Office building facility l Banks l Restaurants l Hotels l Seniors' Centres l Hospitals l New buildings l Renovations l Flat or house construction 18

19 Technical data FiX KC3A Operating conditions of KC3A: t max 48 C Weight incl. water: 6.5 kg/m² Heat-conducting baffles / element: 3 pieces Pipeline length: approx m/m² Pipe dimension: Module pipe d12 mm oxygen barrier Element length: mm in steps of 250 mm freely selectable Grid spacing: 333 mm Test pressure: max. 6 bar Flow rate 0.7 l/m² Calculation example Office space 20.0m² Coverable ceiling surface approx. 70% 14.0m² Room temperature in winter 20 C Room temperature in summer 26 C Supply air (SA) temperature winter 37.5 C Room air (RA) temperature winter 32.5 C SA temperature summer 15 C RA temperature summer 17 C Panelling: 10mm plaster/graphite panel Calculation of the mean temperature in winter: (t SA- Winter + t RA- Winter ) t Over = tspace-winter 2 ( ) t over = 20 = 15 [K] 2 According to the diagram, 15 K of mean overtemperature equates to a specific heating output of approx. 97 W/m² Calculation of the mean temperature in summer: (t SA- Summer + t RA-Summer ) t = t Under 2 space-summer ( ) t over = 26 = 10 [K] 2 According to the diagram, 10 K of mean undertemperature equates to a specific ing output of approx. 84 W/m² For the planned office, this would result in heating output of approx. 97 W/m² x 14m² = 1358 Watts and ing output of approx. 84 W/m² x 14 m² = 1176 Watts. Performance diagram for FiX ceiling ing-heating meander KC3A with various panelling Output according to ÖNORM EN mm plaster/graphite λ 0.52 (ing) mm plaster λ 0.3 (ing) mm plaster perforated 8/18 λ 0.3 (ing) q [W/m 2 ] mm plaster λ 0.25 (ing) 10mm plaster/graphite λ 0.52 (heating 10mm plaster λ 0.3 (heating 50 10mm plaster perforated 8/18 λ 0.3 (heating Over- under-temperature= (T mean T room ) [K] 12.5mm plaster λ 0.25 (heating 19

20 C O O L I N G S Y S T E M S FiX KC4A The suspended ceiling The FiX KC4A ceiling heating and ing module for installation in suspended roof structures. The elements are suitable for use in new buildings, as well as for subsequent installation with renovations. Through the customised size adaptation, the modules can be used for all conventional ceiling structures. The use of heat-conducting baffles guarantees an optimum transfer of energy into the ceiling structure, so that even heat/cold distribution within the ceiling is guaranteed and maximum output is reached. FiX KC4A set-up l Plastic pipe 10 x1.3mm installed in a meandering shape, oxygen barrier l Heat-conducting baffles with omega-shaped beads for holding the plastic pipe l Special support profiles made of galvanised sheet metal, which are connected to the heat-conducting profiles and serve as bracing and for suspending the elements in the sub-structure l On the top of the module, heat insulation made of polystyrene has been applied on site (EPS thickness: 15mm) l The pipe connections of the heating and ing modules take place using radial pressing and push connections l Through a special system structure, an appropriate even contact pressure is ensured on the panelling provided on site Advantages l Architectural freedom with ceiling and interior design (seamless plasterboard ceilings, perforated acoustic ceilings, free interior design) l Heating and ing with one system reduces the generation costs l No formation of cracks at the panel joint, as the KC4A heating and ing coils are uncoupled as overlay modules from the plasterboard ceiling/the visible elements of the ceiling l Good heat transfer to the temperature transition plates through extensive heatconducting baffles l Outstanding controllability of the system l Optimal thermal comfort in summer and winter l Clear separation of trades between drywall builder and installer in relation to the assembly and therefore a clear warranty delineation Areas of application l Office building facility l Banks l Restaurants l Hotels l Seniors' Centres l Hospitals l New buildings l Renovations l Flat or house construction 20

21 Technical data FiX KC4A Operating conditions of KC4A: t max 48 C Weight incl. water: 9 kg/m² Heat-conducting baffles / element: 4 pieces Pipeline length: approx. 24m/m² Pipe dimension: Plastic pipe d10mm oxygen barrier Element length: mm in steps of 200 mm freely selectable Grid spacing: 333mm Test pressure: max. 6 bar Flow rate: 1.0 l/m² Fire protection test in accordance with ÖNORM EN Classification B s1,d0 Calculation example Office space 20.0m² Coverable ceiling surface approx. 70% 14.0m² Room temperature in winter 20 C Room temperature in summer 26 C SA - temperature winter 37.5 C RA - temperature winter 32.5 C SA - temperature summer 15 C RA - temperature summer 17 C Panelling: 10mm plasterboard Calculation of the mean temperature in winter: (t t = SA- Winter + t RA- Winter ) t Over space-winter 2 ( ) t over = 20 = 15 [K] 2 According to the diagram, 15 K of mean overtemperature equates to a specific heating output of approx. 69 W/m² Calculation of the mean temperature in summer: (t t = SA- Summer + t RA-Summer ) t Under 2 space-summer ( ) t over = 26 = 10 [K] 2 According to the diagram, 10 K of mean undertemperature equates to a specific ing output of approx. 62 W/m² For the planned office, this would result in heating output of approx. 69 W/m² x 14m² = 966 Watts and ing output of approx. 62 W/m² x 14 m² = 868 Watts. 125 Performance diagram for FiX ceiling ing-heating module KC4A Output according to ÖNORM EN q [W/m 2 ] KC4A with 10mm plaster λ 0.28 (ing) 10mm plaster λ 0.28 (heating Over- under-temperature= (T mean T room ) [K] 21

22 C O O L I N G S Y S T E M S Assembly instructions KC3A and KC4A Ceiling design: For the assembly of the FiX KC3A or KC4A elements, it is necessary to consult with the drywall builder. He should be integrated into the planning of the assembly procedure as early as possible. All installations in the suspended ceiling must be notified prior to the installation of the ingheating elements (light, fire alarm, sprinkler, ventilation etc.) The production of the ing-heating elements will be started after the approval of the reflected ceiling plan. ceiling slab 130 mm air space Support rail Panelling KC4A incl. insulation 333 C-profile General points that must be provided on site! l The sub-structure must be installed at a minimum distance of 13 cm to the ceiling. (Space requirement for assembly of the connection lines and distributors) l The C-profiles of the drywall builder, which support the KC4A or KC3A elements are preassembled at a distance of 333 mm. l Measure the grid of the ceiling in consultation with the drywall builder and mark the connection points for the KC3A or KC4A elements to the supply line on the ceiling slab. l Various installations, such as ventilation, electric fire alarms etc. must have taken place prior to suspending the KC3A or KC4A elements. l protective tube for the supply line of the dew point sensor must be installed. 22

23 Assembly instructions for the elements and connection lines Assembly of the KC3A or KC4A elements: 1. Install the supply lines below the ceiling slab. Please note that the modules must be connected according to the Tichelmann procedure. 1.1 It is recommended to insulate the connection lines, so that the necessary energy requirement of the KC4A or KC3A elements is ensured. 2. After the ceiling structure has been installed by the ceiling builder, (distance of the C-profiles 333mm), the KC3A or KC4A elements can be suspended in the grid. 2.1 Lift the module into its position and cut one side of the module into the C-profile. 3. Lift the other side of the module, slide the loose C-profile into the correct position below the hook of the element and allow the module to lower. 3.1 The KC4A module is now hanging between two C-profiles, the assembly is completed. 3.2 The KC3A module is affixed to the substructure by additionally locking the holding rail into the C-profile through a barbed hook. 4. The assembly of the modules takes place individually. 3.1 KC4A 3.2 KC3A 23

24 C O O L I N G S Y S T E M S Installation instructions and implementation KC3A and KC4A l The individual KC3A or KC4A elements are connected using the Tichelmann system (shortest return flow and longest flow or installed oppositely and connected hydraulically). l The maximum pipe length of the KC3A or KC4A modules should not exceed 40m. In the factory, the KC4A modules will be produced with a maximum length of 5m and the KC3A modules with a maximum length of 3m. l With serial interconnection of KC3A or KC4A modules, the total d10 or d12 pipe length must not exceed 40m. l Connection lines in d16 or d20 to the KC3A or KC4A modules should be sized according to the output requirement and kept as short as possible. This ensures that the planned pressure loss is not exceeded. To obtain optimum hydraulic balancing, the pipe length deviation of the individual ing and heating circuits elements can be a maximum of 15%! l To connect small modules to a ing or heating circuit with long elements, smaller elements can be switched in series with one another. 24

25 Connection options for KC3A and KC4A Standard option where all modules of a heating circuit have the same length When connecting differently sized element, the deviation from the shorter module to the longer module is permitted to be a maximum of 15%. Integration of shorter modules by connecting several heating circuits into one heating circuit. The length deviation from the shorter module to the longer module is permitted to be a maximum of 15%. Installation example with serial interconnection of KC4A or KC3A element. The length deviation of the elements switched in the series must not exceed 15%. As can be seen from the examples, various module lengths can be connected into one heating circuit. It is important that the length deviation of the partial heating circuits (modules) is a maximum of 15%. 25

26 C O O L I N G S Y S T E M S FiX KC90B The component activation The FiX KC90B system quick-reaction component activation is component tempering that is near to the surface for heating and ing buildings. Through the high efficiency and short reaction time, it is particularly well suited for meeting the present comfort requirements in modern buildings. The pipes, which are set in concrete in a position near the ceiling, guarantee optimum heat, or cold transition to the premises below, so that heating or ing can take place as required, without wasting valuable energy due to storage masses that are difficult to regulate. The use of component tempering must be taken into account for the statistical calculation of the ceilings. The system is tested for fire safety in accordance with EN 1365 and corresponds to a F90 design. FiX KC90B set-up l Large-format modules with pipe registers made of 12 x1.4mm plastic pipe, oxygen barrier l clamping rails for optimum mounting of the plastic pipe guarantee the production of ceiling design that is ready for painting l The structural steel mesh as a top covering that can be walked on serves to protect from mechanical damage to the pipe and to fasten the clamping rails l The connection pipes of the pipe registers are inserted into formwork protectors, so that the individual pipe registered can be connected later without any problem. l The heating and ing modules are produced individually by customer request, on a project basis l The pipe connections of the heating and ing modules take place using radial press connections Advantages l Large-format heating and ing modules are prefabricated in the factory individually by customer request, on a project basis l Architectural freedom with the ceiling and interior design l Quick-reaction controllability with heating and ing mode, regardless of the storage mass l High ing/heating output due to the installation near the surface of the ceiling and to the close distance between pipes l Reduces the system costs heating and ing with one system l Increases comfort and thermal comfort l Optimal for the new of renewable energies for heating and ing Areas of application l Office building l Banks l Shops l Hotels l Seniors' Centres l Hospitals l New buildings l Flat or house construction 26

27 Technical data FiX KC90B Pipe operating conditions of KC90B: t max 70 C at 6 bar Pipe distance: 90mm Pipe dimension: Plastic pipe d12 mm oxygen barrier Module size: freely selectable up to max. 4.5 m 2 with a max. side length of 6 m Module height: approx. 35mm Test pressure: max. 6 bar Flow rate: 0.75 l /m 2 The system is tested for fire safety in accordance with ÖNORM EN and ÖNORM EN Classification according to ÖNORM EN REI 90 Calculation example Office space 20.0 m² Coverable ceiling surface approx. 80% 16.0 m² Room temperature in winter 20 C Room temperature in summer 26 C SA temperature winter 37.5 C RA temperature winter 32.5 C SA temperature summer 15 C RA temperature summer 17 C Plaster thickness: 2 mm Calculation of the mean temperature in winter: (t t = SA- Winter + t RA- Winter ) t Over space-winter 2 ( ) t over = 20 = 15 [K] 2 According to the diagram, 15 K of mean overtemperature equates to a specific heating output of approx. 78 W/m² Calculation of the mean temperature in summer: (t t = SA- Summer + t RA-Summer ) Under t 2 space-summer ( ) t over = 26 = 10 [K] 2 According to the diagram, 10 K of mean undertemperature equates to a specific ing output of approx. 77 W/m² For the planned office, this would result in heating output of approx. 78 W/m² x 16 m² = 1248 Watts and ing output of approx. 77 W/m² x 16 m² = 1232 Watts. Performance diagram for FiX component activation near the surface KC90B Output according to ÖNORM EN q [W/m 2 ] mm plaster (Cooling) 10mm plaster (Cooling) 2mm plaster (Heating) 10mm plaster (Heating) Over- under-temperature= (T mean T room ) [K] 27

28 Assembly instructions KC90B modules For the assembly of the FiX KC90B elements, it is necessary to consult with the construction company. This should be integrated into the planning of the assembly procedure as early as possible. All installations in the concrete ceiling must be notified prior to the installation of the ingheating elements (light, fire alarm, sprinkler, ventilation etc.) The production of the ing-heating elements will be started after the approval of the reflected ceiling plan. Construction process of the individual trades The following work steps are performed by individual professionals: Ceiling formwork Modules for heating and ing ceiling Connection lines Electrical junction boxes Electrical conduits Lower ceiling reinforcement Upper ceiling reinforcement Construction company Installer Installer Electrical company Electrical company Construction company Construction company General points that must be provided on site! l Availability of a storage space of approx. 10 x 6 m in the work area of the building crane for the storage of the heating and ing ceiling modules. l The large-format pallet with the heating and ing modules must be lifted onto the ceiling formwork of the respective storey using a building crane. l Measuring points in the building corner area, or the window axes and support pillars must be drawn onto the ceiling formwork. upper ceiling reinforcement In-situ concrete lower ceiling reinforcement 35 mm mesh mat 90 m m Pipe clamping rail Heating-ing pipe Plaster 1 2 mm 28

29 Assembly of the KC90B modules 1. Positioning of the KC90B elements on the formwork on site. 1.1 Outlets and partition walls must be drawn onto the formwork on site, so that precise positioning of the individual elements can be ensured. 2. Affix the element to the formwork using stainless steel nails, so that the position of the individual elements is fixed. The tips of the nails are removed with pliers after the removal of the formwork. 3. Install the connection lines from the module to the formwork protector in a conduit and check the correct positioning of the protective caps on the pipe ends, so that the penetration of dirt into the pipe ends is prevented. 4. Mount the formwork protectors separately for each of the flow and return lines on the formwork (stainless steel nails). Insert the flow and return lines of the modules separately into the entire length of the formwork protectors. Ensure that the protective pipe is pushed cleanly into the formwork protector, so that no concrete can penetrate into the formwork protector. 29

30 5. With various ceiling installations, such as junction boxes, ventilation outlets or light outlets, the pipes are ducted around them. The clamping rails and structural steel mesh are pinched out in this area. 6. Installation of the 1st reinforcement layer by the construction company 7. Installation of the 2nd reinforcement layer by the construction company 8. Concreting of the ceiling by the construction company 9. After the ceiling concreting work has been concreted and the ceiling has hardened, the formwork can be removed and the protruding nail tips can be removed. 10. On the ceiling, the flow and return supply lines are mainly installed in corridor area for modules and insulated, if necessary. 11. The connection lines of the individual modules are attached to the connection lines using the Tichelmann system. 30

31 Installation instructions and implementation KC90B l The individual KC90B modules are connected using the Tichelmann system (shortest return flow and longest flow or installed oppositely and connected hydraulically) l Connection lines in d20 to the KC90B modules should be sized according to the output requirement and kept as short as possible. This ensures that the planned pressure loss is not exceeded. l To connect small modules to a ing or heating circuit with long elements, smaller elements can be switched in series with one another (total pipe length d12 max. 60 m). To obtain optimum hydraulic balancing, the pipe length deviation of the individual ing and heating circuits elements can be a maximum of 15%! l The maximum pipe length of the KC90B modules should not exceed 60 m. l In the factory, the KC90B modules will be produced with a maximum size of 4.5 m². With a maximum side length of 6 m (pipe length 60 m). l With serial interconnection of KC90B modules, the total d12 pipe length must not exceed 60 m. 31

32 FiX KCLC1 heating and ing system The FiX KCLC1 system is comprised of prefabricated ceiling modules for heating and ing buildings. Through the high efficiency and short reaction time, it is particularly well suited for meeting the present comfort requirements in modern buildings. The elements, which are attached to the ceiling, guarantee optimum heat, or cold transition to the premises below, so that heating or ing can take place as required, without wasting valuable energy due to storage masses that are difficult to regulate. The use of the KCLC1 does not need to be taken into account for the statistical calculation of the ceilings. FiX KCLC1 set-up l Large-format modules with pipe registers mad of KELOX module pipes PE-RT/AL/PE-RT, 16x2mm oxygen barrier l Mesh made of galvanised wire, mesh width 100 x100mm l Standard module 2.7x2.2m, installation distance from pipe: 100mm l Corrosion-resistant materials throughout l The connection pipes for the pipe registers are routed on the ceiling l The heating and ing modules are produced on a project basis l The pipe connections of the heating and ing modules take place using the standard KELOX product range Advantages l Large-format heating and ing modules are prefabricated in the factory. l Short assembly times due to prefabricated registers l Architectural freedom with the ceiling and interior design with open ceilings l Quick-reaction controllability with heating and ing mode, regardless of the storage mass l High ing and heating output by due to installation on the ceiling l Reduces the system costs heating and ing with one system l Increases comfort and thermal comfort l Optimal for the new of renewable energies for heating and ing l Low operating costs due to geothermal energy and solar energy Areas of application l Office building l Shop premises l Warehouse and production halls l New and old buildings l Event centres l Industrial plants 32

33 Technical data FiX KCLC1: Pipe operating conditions of KCLC1: t max 90 C at 10 bar Pipe distance: 100mm Pipe dimension: Module pipe 16/2mm oxygen barrier Module size: 2.7x2.2m Module height: approx. 24mm Test pressure: max. 6 bar Flow rate: 1.15 l/m² Fastening points: approx. 3 pieces/m 2 Joining technology: KELOX standard range Calculation example Office space 20.0m² Coverable ceiling surface approx. 80% 16.0m² Room temperature in winter 20 C Room temperature in summer 26 C SA - temperature winter 37.5 C RA - temperature winter 32.5 C SA - temperature summer 15 C RA - temperature summer 18 C Calculation of the mean temperature in winter: (t t = SA- Winter + t RA- Winter ) t Over space-winter 2 ( ) t over = 20 = 15 [K] 2 According to the diagram, 15 K of mean overtemperature equates to a specific heating output of approx. 57 W/m² Calculation of the mean temperature in summer: (t t = SA- Summer + t RA-Summer ) t Under 2 space-summer ( ) t over = 26 = 9.5 [K] 2 According to the diagram, 9.5 K of mean undertemperature equates to a specific ing output of approx. 50 W/m² For the planned office, this would result in heating output of approx. 57 W/m² x 16m² = 912 Watts and ing output of approx. 50 W/m² x 16 m² = 800 Watts. Performance diagram for FiX KCLC1 ing ceiling system Output according to ÖNORM EN q [W/m 2 ] KCLC1 (ing) KCLC1 (heating)

34 Assembly instructions FiX KCL1: For the assembly of the fix KCLC1 modules, consultation is required with the construction company, as well as the subsequent trades (installer, drywall builder, electrician etc.). The professionals should be integrated into the planning of the assembly procedure as early as possible. All of the system parts and designs for mounting on the ceiling must be clarified in advance. General points that must be provided on site: l availability of a storage space l if possible, the large-format pallets with the KCLC1 should be lifted onto the ceilings of the respective storeys using a construction crane (pay attention to entry portal) l clarification of the type of mounting on the ceiling (concrete, sheet metal, wood etc.) l integration of the assembly into the construction schedule, as the KCLC1 elements must be installed on the ceilings prior to all other ceiling installations. l in the areas fitted with KCLC1, no closed false ceilings are permitted to be planned. Mounting options on the ceiling, e.g. concrete ceiling, trapezoidal sheet metal ceiling Ceiling slab Construction steel 100mm Mesh mat 100x100mm Heating-ing pipe Composite pipe d16 / 2mm Construction steel Mesh mat 100x100mm Insulation 100mm Heating-ing pipe Composite pipe d16 / 2mm 34

35 Assembly process FiX KCL1: Min. 2.5 m For smooth-running mounting of the modules, it is recommended to use an assembly team comprised of several people. 1. Bringing in the modules a sufficient passage width and height must be provided for this. It should be possible to bring these in using an extended forklift truck or two forklift trucks. 2. Measurement of the modules The measurement of the modules can take place individually, for connection lines on the same level as the modules, the space requirement must be planned in. For the measurement of the modules, a string line or laser measuring device should be used. 3. Correct positioning The individual modules are positioned at the planned location on the ceiling using a panel lifting device (lifting height is a minimum of room height) 4. Mounting the modules Depending on the type of ceiling, the modules are mounted using suitable mounting materials (e.g. nail gun nails, wall plugs and screws, self-tapping screws etc.). Mobile mounting frames are usually used for this purpose. 5. Pipework for the connection lines For optical reasons, the installation of the connection lines should take place in parallel with the modules, preferably using KELOX bars. In practice, the KM610 FB clamping rail has been well-proven as a mount for the connection lines on the underside of the ceiling. 35

36 FiX KC75W climate panel element for the wall FiX climate panel element, the wall heating and ing system for drywall, is comprised of 15 mm thick plasterboard with heating or ing pipes integrated in the factory. Simple assembly of the system panels on the drywall structures, the pipes lie on the back in omega-shaped, milled pipe ducts in the panel element. This set-up guarantees quick-reacting temperature control, the surface is ready for painting. The FiX climate panel elements create comfort in new buildings, as well as old building and have a positive effect on the household budget due to low energy consumption. FiX KC75W set-up l System climate panels made of plasterboard material with a 15mm wall thickness and integrated plastic pipes d10x1.3mm, oxygen barrier. l The pipe connections of the heating and ing modules take place using radial pressing and push connections Advantages l Architectural freedom with the interior design l Quick-reaction controllability with heating and ing mode, regardless of the storage mass l High ing and heating output by due to installation near the surface within the wall l Reduction of system costs heating and ing with one system l Increases comfort and thermal comfort l Optimal for the use of renewable energies for heating and ing l Used in both new and old buildings Areas of application l Office building l Banks l Shops l Hotels l Seniors' Centres l Hospitals l New buildings l Renovations l Flat or house construction 36

37 Technical data FiX KC75W Operating conditions of KC75W: t max 48 C Pipe distance: 75mm Pipe dimension: Plastic pipe d10 mm oxygen barrier Module sizes: Module thickness: 15mm Test pressure: max. 6 bar Flow rate: 0.8 l /m 2 Weight: 16 kg/m x 625mm 2000 x 310mm 1000 x 625mm Calculation example: Lounge 20.0m² Coverable ceiling surface approx. 60% 12.0m² Room temperature in winter 20 C Room temperature in summer 26 C Supply air (SA) temperature winter 35 C Room air (RA) temperature winter 30 C SA temperature summer 16 C RA temperature summer 19 C Calculation of the mean temperature in winter: (t t = SA- Winter + t RA- Winter ) t 2 Over space-winter ( ) t Over = 20 = 12.5 [K] 2 According to the diagram, 12.5 K of mean overtemperature equates to a specific heating output of approx. 75 W/m² Calculation of the mean temperature in summer: (t t = SA- Summer + t RA-Summer ) t Under 2 space-summer ( ) t Over = 26 = 8.5 [K] 2 According to the diagram, 8.5 K of mean undertemperature equates to a specific ing output of approx. 55 W/m² For the planned lounge, this would result in heating output of approx. 75W/m² x 12m² = 900 Watts and ing output of approx. 55 W/m² x 12m² = 660 Watts. Performance diagram for FiX KC75W plaster climate panel elements Output according to ÖNORM EN q [W/m 2 ] mm plasterboard (Cooling) 15mm plasterboard (Heating) Over- under-temperature= (T mean T room ) [K] 37

38 Assembly instructions Wall design General points that must be provided on site! l The assembly of the FiX KC75W elements takes place in consultation with the drywall builder. l The consultation should be integrated into the planning of the assembly process as early as possible. Mounting distances for KC75W elements l Prior to bringing in the wall heating system, it must be ensured that the wall surfaces comply with DIN and the electrical and sanitary works have been completed. l The required wall structure must comply with ÖNORM B regarding thermal insulation. l The processing instructions of standard plasterboard manufacturers should be observed for processing. The system panels must be protected from moisture when being stored on the construction site. The FiX KC75W wall ing and heating elements cannot be used for a co-supporting or bracing function. l The elements are mounted onto an appropriate sub-structure, such that the pipes are arranged on the back Wall PE-RT pipe 10 x 1.3 C-profile or wooden structure Plasterboard 38

39 Assembly of the FiX KC75W elements 1. Assembly the first KC75W element on the prefabricated wall structure. 2. The mounting of the modules takes place at a distance of 250mm onto the sub-structure. Pay attention to the space requirement underneath the elements for joining the connecting lines. 3. Various joining techniques are available for connecting two panels on the surface (see installation instructions of the panel/adhesive and putty manufacturers). a. Adhesive joint b. Putty joint (5 7mm) with rightangled edge c. Panels with drywall edge 5. The individual KC75W elements are combined into ing and heating circuits using the Tichelmann system (shortest return flow and longest flow or installed oppositely and connected hydraulically). 6. To obtain optimal hydraulic balancing, half (½) KC75W elements are interconnected in a series into a whole (1) element. 7. With the serial interconnection of several KC75W elements, the total pipe length d10 of 40m must not be exceeded. 8. Connection lines in d20 to the KC75W elements must be sized according to the output requirement and kept as short as possible. The total loss of pressure within the system must be calculated according to the output requirement. Adhesive joint Putty joint Putty joint Drywall edge 3 module sizes with factory-installed PE-RT pipes d 10 x 1.3 mm 2000 x 625 mm pipe length: 16 running metres (1) 2000 x 310 mm pipe length: 8 running metres (½) 1000 x 625 mm pipe length: 8 running metres (½) 39

40 Sizing and loss of pressure For FiX pipe: d10 and 12mm For KELOX module pipe: d16 and 20mm The calculation of the pressure losses takes place according to the Nikuradse formula: R = m di Pipe roughness: mm R = Pipe friction pressure gradient (Pa/m) m = Mass flow (l/sec) di = Inner pipe diameter (mm) ture legend: Water speed m/sec Water volume litres/h Loss of pressure 40

41 Important system components for the connection lines The main pipework and connection lines from the cold and heat generators to the manifolds/shut-off valves rely on a coordinated "system infrastructure of various pipe systems". Nothing is left to chance here. FiX KC590 air distributor 5/4" Operating conditions: PN16: 20 C/16bar; 30 C +40 C/10bar PN10: 20 C/10bar; 30 C +30 C/8bar : PN16 from d20 125mm Polyfusion welding PN10 from d20 160mm 160mm - butt welding Modular pipe system l ing and heating circuit outputs 3/4" Eurocone male thread l distributor connection with detachable nut 6/4" and double nipple 5/4" male thread l compact control, regulating, shut-off and measurement valve in flow l water volume adjustment from l/min presettable l flow rate, differential pressure and pressure loss measurement via measurement nipple on flow valve recordable on measurement computer l standard connection for thermostatic heads M30 x 1.5mm l ball valves 3/4" Eurocone male thread in return flow l bleeding and rinsing connection at the highest point in the flow and return flow l noise-insulated suspension consoles Area of application and classification according to ÖNORM EN ISO Radiator connection class 5 PN10: up to 80 C t max 90 C/10 bar Surface heating class 4 PN10: up to 60 C t max 70 C/10 bar : d16 75mm steel METAL PIPE SYSTEMS steelfix C-steel pressing system Operating conditions: PN16: 20 C to 110 C; t max 120 C/16bar : d15 108mm 41

42 Regulation of the FiX systems Room temperature controllers offer the user the possibility of individually regulating the temperature of each room. l If commercially available room thermostats have dew point sensors input and these are compatible with the dew point sensor, they can be used for controlling FiX systems. l In this case, the KELIT KC562 dew point sensor is required, it must be used as an interface to the commercially available room thermostat of the KC560 dew point sentinel. (see pages 44 and 45) l The temperature perception is different with surface ing than with air conditioning or fan coil systems. l On many days, surface ing systems can be operated with a higher air temperature level than fan coil systems. l Therefore, energy savings can be achieve with at least the same or higher comfort level. Dew point control for the ing mode The dew point control is used in order to prevent the formation of condensation on the pipes and modules. A dew point sensor should basically be installed in every room where ing takes place. These sensors ensure that the ing surfaces are switched off if the dew point limit is exceeded. If the relative humidity reaches a critical point, the KC562 temperature sensor, in combination with the KC560 dew point sentinel, or KC594 climate controller, interrupts the power supply to the ing modules with an actuator. KC V and 24 V KC manifold KC manifold Example: Room air temperature 26 C Relative humidity: 55% Dew point temperature according to the table: 16.3 C ew point temperature in C Relative humidity in % 30% 40% 50% 55% 60% 65% 70% 75% 80% 85% 90% 95% Temperature in C

43 Positioning of the dew point sensors The dew point sensors should be mounted in the est or dampest area of the room, as far as possible. This position is usually in the vicinity of the windows. KC4A / KC3A FiX ceiling ing and heating element With suspended ceilings, the dew point sensor is mounted onto the pipe with a cable tie and the ready-mounted double-sided adhesive tape, so that the sensor tips pierce the ceiling panels and can measure the humidity of the room. The ends of the sensor tips that protrude are closed and must be cut off after the paintwork is completed. KC90B FiX component activation near the surface With concrete ceilings, an electric socket must be installed in the formwork for assembly of the dew point sensor; a pipe of the KC90B module is installed through this. The KC562 dew point sensors are mounted onto the pipe in the same way as with KC4A. The ends of the sensor tips that protrude are closed and must be cut off after the electric socket is uncovered and the paintwork is completed. KC75W FiX climate panel element If a dew point sensor is required, the positioning takes place in the same way as the KC4A fix ceiling ing and heating element. KC562 dew point sensor Insulation PB pipe 10 x 1.3 Plasterboard panel KC562 dew point sensor Concrete ceiling KC90B 43

44 Hydraulic connection diagrams for ing ceilings For the system to function properly, a detailed calculation of the building (ing loads, shade, insulation values, etc.) must be prepared during the planning phase by the developer, architect or building services planner. Furthermore, professional installation and adjustment of the system is essential. The temperature and dew point control takes place by the KC594 climate controller. Connection diagram with cold water generator KELIT FiX supply range CK594 climate controller (ing 1-manifold) Cold water generator Bleeder valve Safety thermostat RT KM 596 thermal motor Water flow adjustment The hydraulic safety and control devices for heating and ing systems must be installed in accordance with the general guidelines and standards TF KC562 dew point sensor Connection diagram with cold water and hot water generator with one manifold KELIT FiX supply range External switching of the KC594 between heating and ing mode Cold water generator Bleeder valve Safety thermostat CK594 climate controller (heating/ing 1- manifold) RT KM 596 thermal motor Hot water generator Water flow adjustment TF KC562 dew point sensor The hydraulic safety and control devices for heating and ing systems must be installed in accordance with the general guidelines and standards 44

45 Connection diagram cold and hot water generator with two manifolds KELIT FiX supply range KC594 climate controller heating/ing with 2-manifold RT Cold water generator Bleeder valve Safety thermostat KM 596 thermal motor Water flow adjustment Hot water generator Cooling ceiling Floor heating TF KC562 dew point sensor The hydraulic safety and control devices for heating and ing systems must be installed in accordance with the general guidelines and standards The controlling of the rooms takes place with a controller provided on site. The interface for the dew point monitoring is the KC560 dew point sentinel. An on/off signal for the dew point sentinel can be switched to any commercially available control unit. Connection diagram with cold water generator KELIT FiX supply range RT Cold water generator Bleeder valve Safety thermostat KC560 dew point sentinel W KM 596 thermal motor Water flow adjustment The hydraulic safety and control devices for heating and ing systems must be installed in accordance with the general guidelines and standards TF KC562 dew point sensor 45

46 Filling the FiX systems: 1. Connect all circuits to the manifold 2. Create a water connection on the flow of the manifold; the return flow is connected to a drain. 3. Ensure that the flow and return flow valves of the circuit to be rinsed are opened completely. 4. Rinse the system with a maximum pressure of 6 bar; use a rinsing pump for this, if necessary, allow the water to circulate at maximum speed until air is no longer escaping from the return flow of the circuit. 5. Connect the rinsed circuit to the flow and return flow and proceed in the same way with the other circuits (Point 3 and 4) Use pressure measurement devices that allow a pressure change of 0.1 bar to be easily read off. The pressure measurement device should preferably be at the lowest position in the system. The result of the leak-tightness test, the testing pressure and testing time must be recorded in a test report. If there is a risk of frost, suitable measured must be taken, e.g. use of anti-freeze, air pressure testing or heating the building. If frost protection is no longer necessary for normal operation, drain the anti-freeze and rinse through the system, changing the water at least three times. If the pressure test is performed with air, it is recommended to carry this out in accordance with ÖNORM B Pressure test KE KELIT recommends testing ing and heating systems on the basis of ÖNORM EN After installation and prior to closing the brickwork slots, wall and ceiling openings, the ing and heating pipelines must be subjected to a pressure test. The ing and heating system must be filled completely with water and bled (protect from frost!). Examine the system for leaks with a water pressure test. The testing pressure must not be less than 4 bar and must not be higher than 6 bar. Remarks: l Temperature fluctuations can influence the testing pressure l Every pressure test is a snapshot of the actual state and cannot be a guarantee against installation errors. l After successful pressure testing, we recommend the preparation of a confirmed test log. 46

47 Pressure test log for ing and heating systems KE KELIT recommends performing the leak-tightness test on the basis of pressure test under ÖNORM EN Every pressure test is a snapshot of the actual state and cannot be a guarantee against installation errors. Attention! Prior to every pressure test, ensure that all points of the assembly instructions (page 12 to 17) have been conscientiously carried out. Pressure test Test the pipeline network with double operating pressure, however at least with 4 bar and up to a maximum of 6 bar, at every point in the system. Only use pressure measurement devices that allow a pressure change of 0.1 bar to be easily read off. The pressure measurement device should preferably be at the lowest position in the system. The temperature equalisation between ambient and filling water temperature must be taken into account after the testing pressure is generated. The testing pressure should be restored after the waiting time, if necessary. All containers, devices and fittings that are not suitable for the testing pressure should be disconnected from the system during the pressure test. The system is filled with filtered water and bled completely. During the test, a visual check of the pipe connectors and screw fittings must be performed. To identify damage to the pipe, testing pressure must be applied to the pipes while the concrete is being inserted. KE KELIT recommends a testing time of 1 hour Calculated testing pressure: Testing time... bar... Hr. During the testing time, NO loss of pressure was determined. The system contains as anti-freeze The system contains NO anti-freeze and has therefore been emptied completely for safety reasons. Place: Object: System pressure:... Confirmation Clerk:... Date:... Time: from... to... Client: Signature/stamp 47

48 Important assembly and installation instructions 1. FiX ing systems are made of plastic and require careful handling in relation to shock, impact, nicks and kinks. 2. Store and transport FiX ing systems (modules) such that they are protected from moisture, dirt and damage. 3. Protect pipes, fittings and conducting parts of the FiX ing system from long-lasting, direct UV exposure. The external protective layer is stabilised against UV influences; however, the pipes must not be exposed to long-lasting, direct sunlight. The conventional storage and processing times are not affected by this. 4. Vitally important! Observe the processing instructions for the screw, press and push connections (page 8-17) l always cut pipes straight, at right angles to the pipe axis l pipe cutter d mm (!) l precisely calibrate KELOX pipe ends l mark the insertion depth for the FiX system using the support sleeve l insert the support sleeve d10 into the end of the pipe l Slide the fittings on completely, without damaging the O-rings l Do not forget pressing with the KELOX system. This is the only way to achieve an axial connection and a permanently tight joint l Push connection: pushed = tight! 5. Avoid using heat to bend pipes; never use open flames! Avoid kinks! Do not install pipes that are damaged or incorrect! 6. Subject each installation to a pressure test in accordance with the standard (page 46). Keep a log of the pressure test (page 47). 7. Water containing glycol for the frost protection is not a problem for FiX. Observe the application instructions of the suppliers. 8. To ensure the warranty services (warranty agreement with the Federal Guild), FiX system components must exclusively be used according to ÖNORM ENV

49 9. Switching/connecting the individual FiX ing elements in the Tichelmann system. (see pages 24 and 25) To obtain optimum hydraulic balancing, the pipe length deviation of the individual ing and heating circuits elements can be a maximum of 15%! 10. Every room with a ing surface should be fitted with a dew point sensor. As the dew point (see table page 42) is not a fixed temperature point, the dew point formation can be minimised by changing the relative humidity downwards. 11. Guideline values for spans of connection lines d16 u. d20 mm of cm. The specified mounting distances prevent waterfilled horizontally installed KELOX pipelines are effectively prevented from buckling. Alternatively, it is possible to apply the distribution line to the substructure of the drywall; insulated connection lines do not require any damping base. If pipes without insulation are used, a damping base is required between the sub-structure and the distribution lines. IN O X 12. Compliance with ÖNORM H Prevention of damage by corrosion and scale formation in closed warm-waterheating systems with operating temperatures of up to 100 C. 13. Use non-corrosive materials for mounting the KC90B modules (e.g. stainless steel nails). 14. Proper calculation, installation and adjustment of the ing and heating surface are required for a feeling comfortable living conditions. 15. Fault-free installation of the FiX system requires a minimum of tools. For your safety, we recommend using the original tools that have been tried and tested many times in practice and their regular servicing. 16. Don't hesitate to consult our application engineers if you are in any doubt. There is no optimal solution for every case, but we can always help. 49

50 Product range overview The FiX ing system constantly adapted to practical requirements and is systematically enhanced. Please see the respective valid FiX ing systems price list for the current status of the supply range. The short symbols (e.g. KC100 = FiX pipe or KC454 = WINDOX-FiX adaptor) significantly simplify ordering and are therefore requested in your order. KC100 KMU100 KM100 FiX pipe FiX pipe system in accordance with DIN 4726 including an oxygen and water vapour EVOH barrier in the middle of the pipe. Operating conditions: t max 70 C/6 bar Colour: d10 PE-RT black d12 PB reddish-brown Supplied in coils KELOX-ULTRAX module pipe KELOX-ULTRAX module pipe conforming to EN ISO 21003, oxygen and water vapour barrier; 5-layered composite pipe made of PE-RT/Al/PE-RT Operating conditions: t max 90 C/10 bar Colour: light grey/transparent or blue Supplied in coils KELOX module pipe KELOX module pipe conforming to EN ISO 21003, oxygen and water vapour barrier; 5-layered composite pipe made of PE-RT/Alu/PE- RT Operating conditions: t max 90 C/10 bar Colour: white/transparent Supplied in coils Flow rate d x s kg/m m 10 x x x x Flow rate d x s kg/m m 12 x x Flow rate d x s kg/m m 16 x x

51 KM110 KELOX module pipe KELOX module pipe conforming to EN ISO 21003, oxygen and water vapour barrier; 5- layered composite pipe made of PE- RT/Alu/PE-RT Operating conditions: t max 90 C/10 bar Colour: white/transparent Straight length: 5m Flow rate d x s kg/m m 16 x x KM134 KELOX Plus pipe 4 mm KELOX-ULTRAX multilayer pipe conforming to EN ISO 21003; oxygen and water vapour barrier; 5-layer multilayer pipe made of PE- RT/Alu/PE-RT; 4mm soft foam insulation; closed cell, protective sleeve made of viscoplastic PE foil Operating conditions: t max 90 C/10 bar Insulation thickness: 4 mm, Colour: blue, Supplied in coils Flow rate d x s kg/m m 16 x x x KC3A FiX ceiling ing heating meander Suspended ceiling ing and heating meander for assembly on substructures prepared on site (grid distance 33.3cm). Comprised of: meandering shaped, bent KELOX-ULTRAX composite pipes d12x 1.5mm, oxygen-tight in accordance with DIN 4726, which are pressed into 3 heatconducting profiles made of aluminium. The power transfer to the panelling on site with plaster climate panels is ensured with special pressuremaintaining elements of the ceiling ing and heating meander. Module width is suitable for substructure on site of 33.3cm. Module length: from 500 to 3000mm available. 3 pieces pipeline length: approx. 11.6m/m² Aluminium heat-conducting baffles: 3 pieces/element Operating conditions - pipe: t max 90 C/10 bar Operating conditions - module: t max 48 C Length Flow rate l/piec e Piec es

52 KC4A FiX ceiling ing and heating module Suspended ceiling ing and heating module for assembly on sub-structures prepared on site (grid distance 333 mm). Comprised of meandering shaped, bent plastic pipes d10x 1.3mm, oxygen-tight in accordance with DIN 4726, which are pressed into 4 corrosion-protected, omega-shaped heat-conducting profiles made of steel plate. Thermal insulation EPS 20, thickness 15 mm is applied above the heating and ing ceiling modules. The overall structure, including 10 mm thermal plasterboard provided on site corresponds to flammability class B1. Module width is suitable for substructure on site of 33.3cm. Module length: from 1000 to 5000 mm available. 3 pieces pipeline length: approx. 24 m/m² Heat-conducting baffles: 4 pieces/element Operating conditions - pipe: t max 70 C/6 bar Operating conditions - module: t max 48 C Length Flow rate l/m Piece s KCLC1 FiX ceiling ing and heating module on structural steel mesh Large-format modules with pipe register made of KELOX module pipes made of PE-RT/AL/PE-RT, 16x2mm oxygen barrier, mesh made of galvanised wire, corrosion-resistant materials throughout h x w pieces 2700mm x 2200mm 1 Pipe distance: 100mm Operating conditions - pipe: t max 90 C/10 bar Operating conditions - module: t max 60 C 52

53 KC90B FiX component activation near the surface 90mm Cooling and heating ceiling module near the surface for assembly on the ceiling formwork. Comprised of prefabricated pipe register, pipe distance 90 mm, made of plastic pipes d12 x 1.5 mm oxygen-tight in accordance with DIN 4726, preassembled on clamping rails on structural steel mesh mats. The fire behaviour of an in-situ concrete ceiling with integrated pipe registers installed near the surface is verified by a fire test in accordance with EN /EN for fire resistance class REI 90. Module size freely selectable up to max. 4,5m² with a max. side length of 6 m Pipeline distance: 90mm 3 pieces pipeline length: approx. 11m/m² Operating conditions - pipe: t max 70 C/6 bar Pipe distance 90 mm KC75W FiX Plasterboard climate panel element including pipe System climate panel made of plasterboard materials with a wall thickness of 15 mm. Comprised of plastic pipes installed in a meandering shape d10 x 1.3 mm, oxygen-tight according to DIN 4726, which are inserted in omega-shaped, milled grooves on the back of the plasterboard panel. h x w x d pieces 1000 x 625 x x 310 x x 625 x 15 1 Pipeline distance: 75mm 3 pieces pipeline length: approx. 13m/m² Operating conditions - pipe: t max 70 C/6 bar Operating conditions - module: t max 48 C 53

54 KC411 FiX push fitting PB pipe Push fitting for FiX pipe made of plastic, including EBDM sealing elements, pull-out barriers and support sleeves for FiX pipe 10 mm 10/10 2 KC444 WINDOX-U-FiX tee on PB pipe Press tee made of Windox-PPSU, including support sleeves with O-rings and stainless steel pressing sleeves, on outlet, push fitting for FiX PB pipe including EPDM sealing elements, pull-out barriers and support sleeves for FiX pipe 10 mm 16/10/16 2 KC444 KC499 WINDOX-U-FiX adaptor to pipe Press adaptor made of Windox-PPSU, including support sleeves with O-rings and stainless steel pressing sleeves, to push fitting for FiX PB pipe including EPDM sealing elements, pull-out barriers and support sleeves for FiX pipe 10 mm FiX support sleeves 16/10 2 Support sleeves for FiX pipe d10 x x KC410 WINDOX-FiX coupling Equal or reducer press coupling made of Windox- PPSU, including support sleeves with O-rings and stainless steel pressing sleeves 12/ /12 10 KC440 WINDOX-FiX tee Equal or reducer press tee made of Windox- PPSU, including support sleeves with O-rings and stainless steel pressing sleeves 20/12/

55 KWU410 KELOX-WINDOX-U coupling Equal or reducer press coupling made of Windox- PPSU, including support sleeves with O-rings and stainless steel pressing sleeves, "leak before pressed" 16/ / /20 10 KMP410 KELOX-PROtec coupling Equal or reducer push coupling made of brass with non-porous metal plating, including support sleeves, O-rings, pull-out barriers and protector ring as locking device 16/ / /20 10 KMP410 KELOX-PROtec-PPSU coupling Equal or reducer push coupling made of PPSU, including support sleeves, O-rings, pull-out barriers and protector ring as locking device 16/ / /20 10 KWU420 KELOX-WINDOX-U elbow 90 Press elbow 90 for changes in direction with a minimal radius; made of Windox- PPSU, including support sleeves with O- rings and stainless steel pressing sleeves, "leak before pressed" KMP420 KELOX-PROtec elbow 90 Push elbow 90 for changes in direction with a minimal radius; made of brass with non-porous metal plating, including support sleeves, O-rings, pull-out barriers and protector ring as locking device KKMP420 KELOX-PROtec-PPSU elbow 90 Push elbow 90 for changes in direction with a minimal radius; made of PPSU, including support sleeves, O- rings, pull-out barriers and protector ring as locking device

56 KWU420 KELOX-WINDOX-U tee Equal or reducer press tee made of Windox- PPSU, including support sleeves with O-rings and stainless steel pressing sleeves, "leak before pressed"- 20/20/20 10 KMP440 KELOX-PROtec tee Equal or reducer push tee made of brass with non-porous metal plating, including support sleeves, O-rings, pull-out barriers and protector ring as locking device 20/20/20 10 KWP440 KELOX-PROtec-PPSU tee Equal or reducer push tee made of PPSU, including support sleeves, O-rings, pull-out barriers and protector ring as locking device 20/20/20 10 KWU450 KELOX-WINDOX-U adaptor with male thread Press adaptor with male thread for sealing, made of Windox-PPSU, including support sleeves with O-rings and stainless steel pressing sleeves, "leak before pressed" DO NOT use any liquid sealants! 16 x 1/2" x 1/2" x 3/4" 10 KMP450 KELOX-PROtec adaptor with male thread Push adaptor with male thread for sealing made of brass with non-porous metal plating, including support sleeves, O-rings, pull-out barriers and protector ring as locking device 16 x 1/2" x 1/2" x 3/4" 10 56

57 KC590E FiX air distributor 1" Flow and return flow bars with 3/4" heating circuit outlets Eurocone male thread, with bleeding and draining at the highest point, distributor ends closed, connections with moulded 1" union nut, flat-sealing, distributor ends with 1" male thread, for screwing together individual distributor bars without additional shaped connectors, double spindle valve on flow - pre-settable, top sections fit KM596 KELOX thermal motor, on return flow, water volume meter (1 5 l/min), brass with nonporous metal plating, including signs that can be labelled for each heating circuit and noiseinsulated plastic consoles. Operating conditions: t max. 80 C/6bar ATTENTION: WITHOUT KM220 Euro screw connection! KC590E FiX air distributor 5/4" Flow and return flow bars (5/4") with ing and heating circuit outlets Eurocone 3/4" female thread, connection option with rotatable valves in screwfitting area, with bleeding/rinsing connection at the highest point, connections with 6/4" moulded union nut, flat-sealing and 5/4" reducing nipple with male thread, distributor ends closed. On flow, compact, control, regulating, shut-off and measurement valve, 3/4" Eurocone male thread, precise regulation pre-settable with adjustment tool from l/min, combines the zone valve and circuit control valve function. Flow and differential pressure measurement recordable using regulating measurement computer, top sections fit KM596 KELOX thermal motor, on return flow ball valve 3/4" Eurocone male thread, brass and non-porous metal plating, including noise-insulated steel consoles for mounting the distributor bars. Operating conditions: t max. 80 C/6bar ATTENTION: WITHOUT KM220 Euro screw connection! Heating circuits 2 L: 175 mm 1 3 L: 225 mm 1 4 L: 275 mm 1 5 L: 325 mm 1 6 L: 375 mm 1 7 L: 425 mm 1 8 L: 475 mm 1 9 L: 525 mm 1 10 L: 575 mm 1 11 L: 625 mm 1 12 L: 675 mm 1 Heating circuits 2 L: 200 mm 1 3 L: 275 mm 1 4 L: 350 mm 1 5 L: 425 mm 1 6 L: 500 mm 1 7 L: 575 mm 1 8 L: 650 mm 1 9 L: 725 mm 1 10 L: 800 mm 1 11 L: 875 mm 1 12 L: 950 mm 1 57

58 KM593A KELOX connection set For manifold connection: reducer or nipple, flat seal brass with non-porous metal plating 1 x 3/4" 1 1 x 1/4" 1 KM593E KELOX Connection ball valve Ball valves in straight or elbow shape for closing the manifold, flat seal male thread for connecting to the manifold, including seal. (RA elbow shape extended) 3/4 1 3/4 elbow " elbow 90 1 KC220 FiX Euro screw connection For connection to installation components with 3/4" EUROCONE (male thread) according to EN215, brass with non-porous metal plating, including nut with female thread, support sleeve with O-rings and clamping ring. Fits KC 100 d12x1.4mm and KMU100 d12x1.5mm O-ring colour: Black 12 x 3/4" 1 KM220 KELOX Euro screw connection For connection to installation components the 3/4" EUROCONE (male thread) according to EN215, brass with nonporous metal plating, including nut with female thread, support sleeve with O- rings and clamping ring. O-ring colour: BLACK 16 x 3/4" x 3/4" 20 KC560 FiX dew point sentinel Dew point sentinel for monitoring the dew point of ing ceiling systems, with use of room thermostats WITHOUT a dew point input, the assembly takes place in a switching or distribution cabinet. Supply voltage: 24V/230V Switching capacity: max. 48V/230V 230V 1 24V 1 58

59 KC562 FiX dew point sensor For measuring and sensing the dew point with ing ceiling systems, the assembly takes place in the ing ceiling on the medium pipe, the sniffer pipes are cut to length after assembly in the ceiling and measure the humidity. incl. 10 m of cable and fastening material for attachment to the pipe for a max. ceiling thickness of 30 mm 1 KC594 FiX climate controller Room temperature controller for direct controlling of the thermal motors KM596 (24V), WITH dew point inlet, for controlling and monitoring the dew point of the ing ceiling WITHOUT using the dew point sentinel KC560 Function - heating and ing with 2 manifolds ( ): 2-circuit control (4-conductor) with one manifold each for heating and ing Function - heating or ing with 1 manifold ( ): 1-circuit control (2-conductor) with one manifold for heating and ing, the switching between heating and ing takes place manually via an external switch Factory-set adjustment range: 21 C +/ 3K The factory-set zero point (21 C) can be adjusted +/ 5K Supply voltage: 24V AC/DC Colour: white H. and C. 1-manifold 1 H. and C. 2-manifold 1 KM596 KELOX thermal motor For assembly on KM590E and KC590E with adaptor for thread M30x1.5 mm (grey) and M28 x 1.5 mm (rot), incl. "first open function" half opened in new condition 230V: Starting current 320mA output 8 ma/2w 24V: Starting current 200 ma output 70mA/2W "closed when currentless" 230V 1 24V 1 59

60 KC610 FiX clamping rail U-profile clamping rail made of plastic with self-clamping pipe fastener for FiX pipes 12mm in 25mm distances L: 1.0m W: 30mm H: 18mm 12mm 20 KM610 KELOX clamping rail Self-adhesive U-profile clamping rail made of plastic with self-clamping pipe fastener in 50mm distances L: 3.9m W: 50mm H: 24mm L: 4.0m W: 50mm H: 24mm 16mm mm 64 KC611 FiX stainless steel nails Stainless steel nails for fastening the FiX component activation elements and formwork protectors to the formwork 2,8 x kg KC613 FiX formwork protector Plastic box for inserting a FiX connection pipe for formwork-protecting installation of the FiX ceiling modules near the surface 300 x 35 x 35 4 KC614 FiX protective pipe Protective pipes for the FiX PB connection pipe between the formwork protector and the individual FiX ceiling modules near the surface

61 KC616 FiX WH pipe clamping rail Profile clamping rail made of plastic with self-clamping pipe fastener for FiX pipes 10mm in 25mm distances L: 800mm W: 15mm H: 13mm KC617 FiX pipe elbow holder Pipe elbow holder for affixing pipe returns with FiX PB pipes d10mm, for clipping in at an angle of 90 into the KC616 WH pipe clamping rail KC699 FiX thermal foil Thermal foil for finding ing or heating lines that are installed underneath plaster or floors 230 x 75mm 1 61

62 WZ916 KELOX calibration mandrel Calibration mandrels for deburring and applying the inner bevel to the KELOX module pipe, mount for slow-running drill or KELOX universal click handle for insertion, suitable for all dimensions. d12 mm incl. handle, not suitable for calibration with drill. Calibration SET 1 comprised of: Calibration mandrel d16, 20, 25 and 1 universal click handle, packaged in case. Calibration SET 2 comprised of: Calibration mandrel d16, 20, 25, 32, 1 universal click handle, bending spring d16, 20, 25, pipe cutter, packaged in case. Calibration SET 3 comprised of: Calibration mandrel d16, 20, 25, 32, 1 universal click handle, bending spring d16, 20, 25, pipe cutter and pipe-holding pliers, packaged in case. Calibration SET 4 comprised of: Calibration mandrel d16, 20, 25, 32, 1 universal click handle, packaged in case. Calibration SET 5 comprised of: Calibration mandrel d16, 20, 25, 32, 1 universal click handle, bending spring d16, 20, 25, pipe cutter, packaged in case. Calibration SET 6 comprised of: Calibration mandrel d16, 20, 25, 32, 1 universal click handle, bending spring d16, 20, 25, pipe cutter, pipe-holding pliers, multi calibration mandrel , packaged in case Click handle 1 Case 1 Set-1 1 Set-2 1 Set-3 1 Set-4 1 Set-5 1 Set-6 1 WZ916 KELOX multi calibration mandrel Multi calibration mandrel for deburring and applying the inner bevel on the KELOX module pipe 16/20/

63 WZ920 KELOX bending spring To form tight bends on KELOX module pipes (smaller than 5d) without reducing the internal diameter L: 610mm d16 and 20 are equipped with a 1.2m extension spring WZ130 KELIT pipe scissors For cutting off KELIT pipes d16 40mm Spare blade 1 Repair set 1 Spare bolt 1 WZ932 KELOX pipe cutter For cutting KELOX module pipes to length up to d Spare blade 1 WZ970 KELIT MINI battery-operated pressing machine Li-ion Electromechanical battery-operated pressing machine - Li-ion 18V 3Ah (Klauke) for pressing KELOX and WINDOX pressing system parts d16 75mm. Steelfix pressing system parts d15-54mm and FiX pressing system parts d12mm including 2 pieces battery 18V and charger 230V for 18V, packaged in case ATTENTION! If used for other brands, please note that a minimum of 30 kn of pressing force is required! KE KELIT recommends that pressing tools are inspected once a year to check that they are functioning correctly and to fulfil the conditions for the warranty. Please contact KE KELIT or the manufacturer of the tools directly! Pressing set 18V 1 Spare battery 18V 1 Charger 18V 1 Blue case 18V 1 63

64 WZ970L KELIT battery-operated pressing machine Li-ion Electromechanical battery-operated pressing machine Li-ion (Rems) for pressing KELOX and WINDOX pressing system parts d16 75 mm, STEELFIX pressing system parts d15 54 mm and FiX pressing system parts d12 mm incl. 2 pieces battery 14.4V Li-ion and charger 230V packaged in steel case without pressing jaws. For retrofitting with electricity-dependent battery power supply WZ971L, 230V Set Basic machine 1 Battery 12V Li-ion 1 Charger 1 Case 1 ATTENTION! If used for other brands, please note that a minimum of 30 kn of pressing force is required! KE KELIT recommends that pressing tools are inspected once a year to check that they are functioning correctly and to fulfil the conditions for the warranty. Please contact KE KELIT or the manufacturer of the tools directly! WZ971L KELIT battery power supply Li-ion Battery power supply 230V Li-ion, for retrofitting for WZ970L 230 V Li-ion 1 WZ980 KELOX pressing jaws U Pressing jaws inserts for pressing the KELOX and WINDOX system parts with a WZ970 or WZ970L KELIT AKKU pressing machine Designation: U-contour KE KELIT recommends that pressing tools are inspected once a year to check that they are functioning correctly and to fulfil the conditions for the warranty. Please contact KE KELIT or the manufacturer of the tools directly!

65 WZ972 KELIT MINI battery-operated pressing machine Li-ion Electromechanical mini battery-operated pressing machine - Li-ion 18V 1.3Ah (Klauke) for pressing KELOX and WINDOX pressing system parts d16-32mm, FiX pressing system parts d12mm incl. battery power supply, reserve battery power supply and charger 230V for 18V charger, identical to WZ970 KELIT battery-operated pressing machine - Li-ion ATTENTION! If used for other brands, please note that a minimum of 30 kn of pressing force is required! KE KELIT recommends that pressing tools are inspected once a year to check that they are functioning correctly and to fulfil the conditions for the warranty. Please contact KE KELIT or the manufacturer of the tools directly! Mini pressing SET 18V 1 Mini battery power supply 18V 1 WZ982 KELOX mini pressing jaws U Pressing jaws inserts (Klauke) for pressing the KELOX and WINDOX system parts with a WZ972 KELIT mini battery-operated pressing machine Designation: U-contour KE KELIT recommends that pressing tools are inspected once a year to check that they are functioning correctly and to fulfil the conditions for the warranty. Please contact KE KELIT or the manufacturer of the tools directly! WZ983 KELOX manual pressing jaws U For manual pressing of the KELOX, WINDOX and FiX pressing system parts Designation: U-contour Manual pressing 1 Inserts 12 1 Inserts 16 1 Inserts

66 Representative offices, production and headquarters The KELOX modular pipe range and CoolFiX ing system is distributed through sanitary and heating wholesale stockists nationwide in accordance with its importance. KE KELIT Headquarters KE KELIT Kunststoffwerk Gesellschaft m.b.h. Ignaz-Mayer-Straße 17 A-4020 Linz, PO Box 36 Tel: +43 (0) Fax: +43 (0) office@kekelit.com The technical contents in this brochure are for your information and consultation. We are not liable for the contents. The application and installation of the products should be adapted to the individual requirements of each project. KE KELIT is constantly improving its products and reserves the right to make technical changes during the course of these improvements. Printing and typographical errors excepted. by KE KELIT FiX Handbook 02/2015 German. 66

67 Representative Office for Upper Austria KE KELIT office Upper Austria Ignaz-Mayer-Straße 17 A-4020 Linz Tel: +43(0) Fax: +43(0) Representative Office for Vienna, Lower Austria and Burgenland KE KELIT office Vienna Campus 21 Liebermannstraße A02405 A-2345 Brunn am Gebirge Tel: +43(0) Fax: +43(0) Representative Office for Styria KE KELIT office Styria Grazer Straße 10 A-8130 Frohnleiten Tel: +43(0) Fax: +43(0) Representative Office for Salzburg KE KELIT office Salzburg Pannzaunweg 1b A-5071 Wals Tel: +43(0) Fax: +43(0) Representative Office for Carinthia KE KELIT office Carinthia Wirtschaftspark 11 A-9130 Poggersdorf Tel: +43(0) Fax: +43(0) Representative Office for Tyrol and Vorarlberg KE KELIT office Tyrol Bahnstraße 14a A-6401 Inzing Tel: +43(0) Fax: +43(0)

68 Certified Quality Assurance System by ÖQS ÖNORM EN ISO 9001:2000 Reg.No. 366/0 MEMBER Member of the Austrian Working Group PLASTIC PIPE RECYCLING ARA Licence No KE KELIT Kunststoffwerk GesmbH. Ignaz-Mayer-Straße 17 A-4020 Linz Austria Europe Tel. +43 (0) Fax +43 (0)

Zehnder ZIP Radiant Ceiling Panels

Zehnder ZIP Radiant Ceiling Panels Zehnder ZIP Radiant Ceiling Panels The Sun a masterpiece! 2 3 The sun radiates warmth and light. Its thermal radiation is only effective when its rays shine on an object. The air is therefore not warmed

More information

Radiant Ceiling. Metawell Klimadecke 1

Radiant Ceiling. Metawell Klimadecke 1 Radiant Ceiling Metawell Klimadecke 1 Grid ceiling and high-gloss sail in a branch of the Sparkasse (Munich) Cooling and heating ceilings Conventional air-conditioning systems barely fulfil the more stringent

More information

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation Cooling and heating systems Static cooling ceiling system SKS-/3 DS 10 E 01.010 Static cooling ceiling system SKS-/3 Main features Preliminary remarks / Applications 3 Main dimensions and materials 3 Construction

More information

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection DS 4094 E 05.2007/1 Technical Selection Main features 2 Preliminary remarks 3 Construction design 3 Main dimensions and materials 3 Design data 3 Layout example 5 Design specifications 8 Installation instructions

More information

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing. b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing. b!klimax is an integrated heating and cooling system that exploits the ability of ceilings and walls to exchange heat and cold with the environment

More information

PRINETO universal system for plumbing and heating

PRINETO universal system for plumbing and heating PRINETO universal system for plumbing and heating Efficient. Simple. Easy to use. The safe plastic pipe system PRINETO Installation quick and easy Cut the PE-X, Nanoflex or Multilayer composite pipe to

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air Heating and cooling ceiling systems Suspended ceiling systems Heating Cooling Fresh Air Clean Air The complete heating and cooling ceiling systems Customers can now order a fully suspended heating and

More information

b!klimax radiant wall/ceiling system

b!klimax radiant wall/ceiling system b!klimax radiant wall/ceiling system by We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and

More information

DUOPEX WATER MANUAL mm

DUOPEX WATER MANUAL mm DUOPEX WATER MANUAL 32-63mm The DUOPEX WATER Pipe and Fitting System is designed for 32mm- 63mm potable hot and cold water applications. This revolutionary alternative for the professional plumber, makes

More information

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: Tank systems Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: NEOPOR AND FLEECE INSULATION SENSOR TERMINAL STRIP ADJUSTABLE FEET www.froeling.com Energy management

More information

aquatherm black Heating and cooling system for ceiling, wall and other applications aquatherm state of the pipe

aquatherm black Heating and cooling system for ceiling, wall and other applications aquatherm state of the pipe aquatherm black Heating and cooling system for ceiling, wall and other applications aquatherm state of the pipe Our sales and delivery conditions (January 2012) and the contacts of our technical sales

More information

TECEflex the universal installation system. Secure connections for the past 20 years

TECEflex the universal installation system. Secure connections for the past 20 years TECEflex the universal installation system Secure connections for the past 20 years Contents TECEflex universal use Page 4 5 TECEflex system advantages Page 6 7 TECEflex processing Page 8 9 TECEflex fittings

More information

Marketing and commercial information of KAN GROUP. Winter novelties in KAN-therm offer!

Marketing and commercial information of KAN GROUP. Winter novelties in KAN-therm offer! Newsletter Marketing and commercial information of KAN GROUP 6/2012 Winter novelties in KAN-therm offer! KAN Company is a manufacturer of modern water and heating systems, which attaches great value to

More information

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold RADIANT PANELS TRENCH PERIMETER GRILLES ELEMENTS PIPER FARM, BROMLEY GREEN ROAD, ASHFORD, KENT. TN26 2EF TEL: 01233 733308 FAX: 01233 733883 E-MAIL: sales@feukltd.com RADIANT PANEL RANGE INTRODUCTION HOW

More information

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems UPONOR Ltd Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems Reference Page(s) UPONOR Q&E PEX 2 Operating Conditions 2 Pipe Properties 2 Fittings Range 3 Radiator Heating Systems 3 H&C Water

More information

HEATING. COOLING. COMFORT. For a cosy home.

HEATING. COOLING. COMFORT. For a cosy home. HEATING. COOLING. COMFORT. For a cosy home. www.variotherm.com VIDEO VIDEO THE VARIOTHERM WORLD AMAZING COMFORT. WITH ATTRACTIVE SAVINGS. Variotherm s floor heating systems, skirting heating systems, trench

More information

C o o l i n g a n d h e a t i n g s y s t e m s

C o o l i n g a n d h e a t i n g s y s t e m s 2 C o o l i n g a n d h e a t i n g s y s t e m s Cooling ceiling system description Preliminary remarks Cooling ceilings Cooling ceilings are room cooling systems for placement in the ceiling zone. Their

More information

DUOPEX WATER MANUAL mm WM WMKA021044

DUOPEX WATER MANUAL mm WM WMKA021044 DUOPEX WATER MANUAL 32-63mm WM-022149 WMKA021044 The DUOPEX WATER Pipe and Fitting System is designed for 32mm- 63mm potable hot and cold water applications. This revolutionary alternative for the professional

More information

Modula Standard Performance

Modula Standard Performance the future of space conditioning Modula Standard Performance heating panel Application Commercial, hospitals, hotels, schools, shops, sports halls, offices, laboratories, food industry etc. Installation

More information

Ceiling office High-performance Radiant Ceiling Systems

Ceiling office High-performance Radiant Ceiling Systems Ceiling office High-performance Radiant Ceiling Systems EN TIEMME, INNOVATION FOR A STEADY GROWTH Tiemme Raccorderie is an international leader in the production and marketing of plumbing and heating

More information

Room heating and cooling for floors, walls and ceilings

Room heating and cooling for floors, walls and ceilings Room heating and cooling for floors, walls and ceilings Contents Index: Page: 1 Index 2 Summary The advantages of surface heating Insulation using insulating material Heat insulation Vapour barrier Edge

More information

Brilliant alternative: Ceiling systems made of metallic mesh

Brilliant alternative: Ceiling systems made of metallic mesh Brilliant alternative: Ceiling systems made of metallic mesh The range of metallic mesh ceiling systems by GKD Gebr. Kufferath AG (GKD) has now been enhanced through the addition of sandwich panels with

More information

Chilled Ceiling Elements

Chilled Ceiling Elements 2/27/EN/2 Chilled Ceiling Elements Type WK-D-WF Convective chilled ceilings providing excellent visual results TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/202-265 Heinrich-Trox-Platz e-mail

More information

Heating and cooling ceiling systems Zehnder ZIP Planning document. Heating Cooling Fresh Air Clean Air

Heating and cooling ceiling systems Zehnder ZIP Planning document. Heating Cooling Fresh Air Clean Air Heating and cooling ceiling systems Zehnder ZIP Planning document Heating Cooling Fresh Air Clean Air Sportforum, Berlin (Germany) Modelled on the sun. The heating effect of the sun's rays a natural principle

More information

Metal Cassette Ceiling with BEKA Heating and Cooling Mats

Metal Cassette Ceiling with BEKA Heating and Cooling Mats TI-K2 Short Description Metal Cassette Ceiling with BEKA Heating and Cooling Mats 1. General Modern office- and business facilities must be cooled mostly throughout the whole year because of the internal

More information

BEKA ceiling heating versus traditional underfloor heating

BEKA ceiling heating versus traditional underfloor heating BEKA ceiling heating BEKA ceiling heating versus traditional underfloor heating 0. Preliminary remark In the future, rooms will be heated and cooled by surfaces providing radiant heating and cooling. The

More information

Technical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe

Technical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe System Insulated Rubber Pipe The 3THERMO radiator (concealed or for drywall installation) is adjusted for serial connections. The recommended system installation is SIRK. The radiator should be covered

More information

A new age in HEATING. ROTEX Monopex The natural way to save energy! The complete heating system

A new age in HEATING. ROTEX Monopex The natural way to save energy! The complete heating system R A new age in HEATING R eco Systems - ROTEX EcoHybrid Heating for your home all from one source The complete heating system - Regenerative air-water Heating Pump - Modern burning Technique - Solar power

More information

experience We carefully design each individual installation to optimise performance Good underfloor heating explained

experience We carefully design each individual installation to optimise performance Good underfloor heating explained 2.7m 23 1.8m Good underfloor heating explained Radiator versus Underfloor Heating 2.7m 1.8m 21 Radiator System Underfloor Heating System Hot air rises. The hotter the air, the quicker it rises. Radiators

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview lindab ventilation Lindab Comfort Product overview Products within the Lindab Waterborne solutions, e.g. chilled beams, facade systems, radiant heating and cooling panels, uses water to regulate the room

More information

Assembly instructions for LK PressPex

Assembly instructions for LK PressPex Assembly instructions for LK PressPex General All water contact parts of LK PressPex are manufactured from dezincification-resistant brass. When installed in radiator systems, fittings are to be protected

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

Thermotech underfloor heating

Thermotech underfloor heating Thermotech underfloor heating Assortment and pricelist 2010 Copyright: Thermotech Scandinavia AB 2009 Cover photo: Michael Engman Graphic design: Ulrika Mattisson Other image material: Michael Engman,

More information

ZIP Radiant Heating and Cooling Ceiling Panels. Catalog

ZIP Radiant Heating and Cooling Ceiling Panels. Catalog ZIP Radiant Heating and Cooling Ceiling Panels Catalog Heating Cooling Fresh Air Clean Air Zehnder everything you need to create a comfortable, healthy and energy-efficient indoor climate Heating, cooling,

More information

The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system

The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system The new standard The advanced solar absorber tube The collector for every budget Efficient modular installation system Intelligent DRC system technology 1 The new standard AMK collectors the new standard

More information

Underfloor heating systems for new build and modernisation

Underfloor heating systems for new build and modernisation Underfloor heating systems for new build and modernisation Regenerative heating in the winter and cooling in the summer. ROTEX underfloor heating systems provide year-round comfort. More cosiness, less

More information

FIRST-CLASS IN TRAINS

FIRST-CLASS IN TRAINS FIRST-CLASS IN TRAINS Powered by TCPDF (www.tcpdf.org) Powered by TCPDF (www.tcpdf.org) Advanced fire protection for railway vehicles: hazard level 2 & 3 according to EN 45545 Effectively prevents moisture

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

The complete energy-saving range.

The complete energy-saving range. The complete energy-saving range. therm-x2 steel panel radiators Heat pumps Heat storage Controls Panel heating/cooling systems Steel panel radiators Domestic ventilation The right time for a new generation

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

INFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump.

INFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump. INFO DUAL Compact GADC Air Cooler for HFC and CO 2 Dual discharge air cooler with and without integrated condensation water pump 2 25 kw As you see, you see nothing Where has the condensation water drain

More information

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8 VARICOOL Velum System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8 All legal and technical information was compiled to the best of our knowledge

More information

Sanpress Inox G. Instructions for Use. Year built: from 02/2004 en_int

Sanpress Inox G. Instructions for Use. Year built: from 02/2004 en_int Sanpress Inox G Instructions for Use Year built: from 02/2004 en_int Sanpress Inox G 2 from 27 Table of contents Table of contents 1 About these instructions for use 4 1.1 Target groups 4 1.2 Labelling

More information

Radical CPD BIM.

Radical CPD BIM. Radical At the forefront of innovation, Stelrad has developed the next generation in energy saving radiators, the Radical. As the first serial feed radiator this ground breaking solution reduces energy

More information

Polaris-I-60. active chilled beam. the future of space conditioning

Polaris-I-60. active chilled beam.   the future of space conditioning the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,

More information

Intelligent Temperature Management. ThermaCool - Say goodbye to inefficient temperature peaks. GeoClima Inclusive Technical Package

Intelligent Temperature Management. ThermaCool - Say goodbye to inefficient temperature peaks. GeoClima Inclusive Technical Package Intelligent Temperature Management ThermaCool - Say goodbye to inefficient temperature peaks GeoClima Inclusive Technical Package ThermaCool incorporating Phase Change Material Phase Change Material Technology

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve

More information

C08. S05. P02 P05 Decorative effects

C08. S05. P02 P05 Decorative effects ! This section includes updated information, added since it was first published in December 2015. Last updated 16/12/2016 C08. S05. P02 P05 Decorative effects Including C08. S01. P02 Finishes introduction

More information

Heating and cooling ceiling systems Zehnder ZBN Planning document. Heating Cooling Fresh Air Clean Air

Heating and cooling ceiling systems Zehnder ZBN Planning document. Heating Cooling Fresh Air Clean Air Heating and cooling ceiling systems Zehnder ZBN Planning document Heating Cooling Fresh Air Clean Air Comfortable, energy-saving, flexible. Zehnder ZBN radiant ceiling panels heat and cool a building

More information

SYSTEM MANUAL Description

SYSTEM MANUAL Description SYSTEM MANUAL Description PUCK is a revolutionary fire suppression system offering discrete protection coupled with industry leading pricing, efficient system design and easy install. PUCK s lightweight

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

Smoke extract fan SMHA HATCH

Smoke extract fan SMHA HATCH 12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection

More information

Decorative radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Zehnder ZBN

Decorative radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Zehnder ZBN Decorative radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Zehnder ZBN Technical document for radiant ceiling panels for heating and cooling Delivering

More information

Fresh air supply systems

Fresh air supply systems Fresh air supply systems Optimum fresh air supply for every type of pig house Fresh air supply systems the right solution for every type of piggery! To ensure an optimum fresh air supply, Big Dutchman

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE Superior 4 in 1 insulation (59) Y November 2008 (K22) FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE Superior 4 in 1 insulation STRAIGHT FROM THE SOURCE S MOUTH... Introducing the most reliable

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Industrial Heaters for Plastic Applications

Industrial Heaters for Plastic Applications Industrial Heaters for Plastic Applications www.nexthermal.com When heat is vital to your application, the right heater configured to your process is the most cost-effective improvement you can initiate.

More information

Secure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil

Secure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil Secure hydraulic system performance Smart solutions for cooling and cleaning hydraulic oil The products and the global support you need How can you ensure that your hydraulic systems achieve their full

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Xpert HD Xpert HD 7140, ,

Xpert HD Xpert HD 7140, , Xpert HD 7140 Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. TECHNICAL

More information

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology HD 5/11 C Plus Compact cold-water high pressure cleaner. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. 1 Automatic

More information

Secondary systems used in Europe.

Secondary systems used in Europe. Secondary systems used in Europe. Production Distribution Consumption Preface Secondary systems are the parts of the heating systems with a lower pressure and temperature level, installed in buildings.

More information

Energy Saving Series RADICAL

Energy Saving Series RADICAL RADICAL The Stelrad Radical Energy Saving Radiator can save up to 10.5% on energy bills, delivering higher comfort levels at a lower thermostat setting. That s radical thinking, from Stelrad. It s the

More information

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning

More information

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22 HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples

More information

Heating and Cooling Panels. Aluline. W a r m l i k e t h e s u n

Heating and Cooling Panels. Aluline. W a r m l i k e t h e s u n Heating and Cooling Panels Aluline W a r m l i k e t h e s u n 2 Contents Introduction 3 Our Goal: Well-being at the workplace 4 Why using Heating and Cooling Panels? 6 Function 7 Advantages of the System

More information

Icopal Screw Fasteners & Accessories

Icopal Screw Fasteners & Accessories CI/SfB January 2015 (47) t6 Uniclass L524

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems NEW Energy systems Thermotank Quadroline The new generation of plastic storage tanks living full of energy Water provides a vital basis for life. It transfers heat in an environmentally friendly way and

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

ACN SMOKE INSTALLATION AND MAINTENANCE

ACN SMOKE INSTALLATION AND MAINTENANCE NovAx ACN SMOKE INSTALLATION AND MAINTENANCE 918149-0 English 918149-0 GB Installation and maintenance NovAx smoke exhaust fan type ACN smoke 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Transport

More information

With the world-renowned SIGMA PROFILE

With the world-renowned SIGMA PROFILE www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor

More information

Build on hygiene with Uponor plumbing systems

Build on hygiene with Uponor plumbing systems Build on hygiene with Uponor plumbing systems Installation worlds from Uponor Composite pipe installation Hygiene flushing stations and monitoring Page 4 Page 8 Page 14 Page 16 Composite pipes Fitting

More information

HDS 801 D. Mobile hot water high-pressure cleaner with comubstion engine for the universal use where no power supply is available.

HDS 801 D. Mobile hot water high-pressure cleaner with comubstion engine for the universal use where no power supply is available. HDS 801 D Mobile hot water high-pressure cleaner with comubstion engine for the universal use where no power supply is available. 1 Maximum independence Efficient four-stroke petrol or diesel engine with

More information

KEMPER ThermoSystem. For further information on KTS use the QR code!

KEMPER ThermoSystem. For further information on KTS use the QR code! KEMPER ThermoSystem Heating water hygienically and energy-efficiently with patented cascade rotation for automated operating change among all heating modules For further information on KTS use the QR code!

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION At a glance: EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION HEDRICH offers a variety of drying technologies for different applications. Only carefully

More information

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS Active chilled beam with cooling, heating and ventilation QUICK FACTS The ADRIATIC VF is a chilled beam with integrated recirculated air opening in the face plate. Air is discharged into the room along

More information

IRRAD - PHASE II RADIANT COOLING - DESIGNING FOR FLEXIBLE PARTITION OF SPACE

IRRAD - PHASE II RADIANT COOLING - DESIGNING FOR FLEXIBLE PARTITION OF SPACE IRRAD - PHASE II RADIANT COOLING - DESIGNING FOR FLEXIBLE PARTITION OF SPACE Cooling System RADIANT COOLING PIPING LAYOUT Proposal for the REHAU core temperature control (CCTC) pipe size: RAUTHERM S 20x2,0mm

More information

HD 7/11-4 Cage Classic

HD 7/11-4 Cage Classic HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure

More information

spc-hvac.co.uk THERMATILE PLUS HEATING & COOLING RADIANT CEILING PANELS INNOVATION WITH STYLE Active

spc-hvac.co.uk THERMATILE PLUS HEATING & COOLING RADIANT CEILING PANELS INNOVATION WITH STYLE Active spc-hvac.co.uk THERMATILE PLUS HEATING & COOLING Active RADIANT CEILING PANELS INNOVATION WITH STYLE ABOUT SPC ABOUT SPC THE COMPANY S & P Coil Products Limited is a UK based specialist manufacturer and

More information

Operating and Maintenance Instructions

Operating and Maintenance Instructions EATON Germany GmbH Werk Lohmar D-53797 Lohmar Operating and Maintenance Instructions WALFORM Machine Electronically controlled - Conforms to CE MEG-WF385X Status: Sept 2011 MEG-WF385X_Stand Sept 2011 SUITABILITY

More information

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke 918149-0 GB Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Transport 3. Storage 4. Installation 4.1 Prior to attachment 4.2 Attachment

More information

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion Socket Heat Fusion Techniques A Guide for Instruction and Training in Vanguard Socket Heat Fusion TABLE OF CONTENTS This brochure has been developed to assist those responsible for socket fusion joining

More information

LINDOFLAMM thermal engineering.

LINDOFLAMM thermal engineering. Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering

More information

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air Heating and Cooling Ceiling Systems Comfortable and energy efficient Heating Cooling Fresh Air Clean Air Comfortable and energy saving. Compromises are often needed when a building needs to be heated or

More information

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation

More information

Always make sure to check the heating film before, during, and after installation of the floor covering.

Always make sure to check the heating film before, during, and after installation of the floor covering. Installation of floor heating film for ceramic tiles, granite and other stone or composite flooring Read through this entire manual before starting installation. All electrical connections must be made

More information

ELSTA MOSDORFER- Energy Distribution with Competence

ELSTA MOSDORFER- Energy Distribution with Competence PRODUCT RANGE ELSTA MOSDORFER- Energy Distribution with Competence Quality and Standards We are your reliable partner for electrical energy distribution, industrial control and automation engineering.

More information

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Smoke Master SMIA Compact pressurisation and smoke exhaust system Smoke Master SMIA Compact pressurisation and smoke exhaust system Fläkt Woods FIFLO EN 2009.09 2 All rights reserved. Contents System overview... 4 Design and operation... 5 Technical specification...

More information