Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier.

Size: px
Start display at page:

Download "Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier."

Transcription

1 Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier. Technical Manual VARIHEAT VH3 AA/AW600/900/00A/BVHXF 500BVHXF SD37360 iss /0/5 HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment, ONLY competent persons should carry out any work on this type of machine. (See Guarantee). Page 38 SD37360 SUE

2

3 CONTENTS.0 HOW THE CALOREX SERIES 3 VARIHEAT SYSTEM WORKS OPERATION....0 INSTALLATION PLUMBING DETERMINING WATER FLOW WATER CONNECTIONS.... ELECTROLYTIC CORROSION IN SWIMMING POOLS ELECTRICAL INSTALLATION....6 CIRCUIT DIAGRAMS REGULAR PLANNED MAINTENANCE CONTROLS COMMSIONING CHECKLT TIME CLOCK SETTINGS POOL & AIR TEMPERATURE AND HUMIDITY CONTROLS DATA SHEET DIMENSION DRAWINGS WARRANTY CONDITIONS LOGIC CONTROL CIRCUITS RELAY FUNCTIONS PARAMETER SETTINGS SOUND GRAPH FAN CURVES REFRIGERATION DIAGRAMS SPARE PARTS LTS CONTROL PANELS CONTROL PANEL REMOTE (OPTIONAL) FRIDGE BOX ASSEMBLIES MAIN FRIDGE COMPONENTS ALL MACHINES EXTRA PIPE WORK FITTINGS, AW600/900 MACHINES ( LPHW) EXTRA PIPE WORK FITTINGS, AW00/500 MACHINES EXTRA PIPE WORK FITTINGS, AW6/900 MACHINES WITH LPHW FITTED EXTRA PIPE WORK FITTINGS, AW/500 MACHINES WITH LPHW FITTED FAN BOX ASSEMBLY SPARE PARTS LT FAN LINK SETTINGS FOR 600/900/00 UNITS FINAL ASSEMBLY SPARE PARTS LT TOP OUTLET FINAL ASSEMBLY SPARE PARTS LT DOWN DRAUGHT FRESH AIR BOX SPARE PARTS LT HEATER BOX ASSEMBLY SPARE PARTS LT REMOTE SENSOR BOX DUCT FLANGE KITS FROST PROTECTION KITS PACKING SPECIFICATIONS... Page 39 SD37360 SUE

4

5 Health and Safety This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance..0 HOW THE CALOREX SERIES 3 VARIHEAT SYSTEM WORKS. The Calorex SERIES 3 VARIHEAT range consists of models: 600/900/00/500. The model number increases in relation to the recirculated air flow from model 600 at 000 m³/h to model 500 at 300 m³/h. 600 and 900 models are fitted with constant flow fans and deliver the optimum airflow, self compensating for pressure differentials in the system. All models are fitted with either one or two console fixing service panels These allow for the console to be fixed to the Variheat 3. These service panels can be fitted on any face of the machine. When optional fresh air box is fitted, all models have the facility to exhaust a percentage of the recirculating air and introduce a slightly lesser amount of fresh air (slight differential creates a negative pressure on pool hall to localise pool environment and protect the building fabric). An optional negative pressure box is also available. This exhausts a percentage of the circulating air without introducing fresh air to the pool hall. Optional, factory fitted frost protection kits are available, for use when the fresh air box is fitted. These kits protect the LPHW from freezing by closing the dampers to min when the ambient temperature is below 6ºC. The first kit controls the machine dampers. A second kit controls the machine dampers and also a remote damper fitted by the customer in the installation ductwork. All AW models are fitted with a fully controlled low pressure hot water air heating battery and a pool water heat exchanger. Provision is made for an external heat source to be initiated by the SERIES 3 VARIHEAT controller. All AW models have air and water heat exchangers recovering energy from the refrigerated dehumidification process. These are also fully controlled with priority given to water. Page 3 SD37360 SUE

6 THE CALOREX SERIES 3 VARIHEAT RANGE. FEATURES :- All versions have removable drip trays for easy cleaning. Control panel can be mounted remotely up to a maximum of 0 metre cable length. Models fitted with a fresh air box or a negative pressure box have motor driven louvres on the exhaust and fresh air dampers. Optional electrical resistance air heater boxes ranging from 6kW to 8kW. The power to each model in the range is fed in via din rail mounted terminal blocks located in the electric box of the unit. CONTROL PANEL. (All Models) Note AA Models do not have a water temperature controller, and do not include a time clock unless fitted with LPHW. The panel has the following features,. Relative Humidity Controller, with red light to indicate dehumidification demand.. Air Temperature Controller, with red light to indicate air heating demand. 3. Water Temperature Controller, with red light to indicator water heating demand.. Fresh Air Switch, with MAX, AUTO and MIN positions (for use with fresh air module or negative pressure box). 5. Economy Switch to select between water heating only or full function on AW versions. 6. On/Off Switch. TE with the switch in the OFF position the machine is still live and mains lamp and clock are energised. 7. Air/Water switch, can be set to give priority to either water heating or air heating. 8. Time clock to control occupied/unoccupied timings with battery back up and manual override. 9. Indicator lights :- Power on Fault Defrost Auto Dehumidification Air heating Water heating (if applicable). CONTROL PANEL (AW version shown, see section 3.0) ECOMY SWITCH AIR/WATER SWITCH % RH ºC ºC MAX AUTO MIN HUMIDITY AIR TEMP WATER TEMP = AUTO = = AUTO Page SD37350 SUE

7 . OPERATION When the SERIES 3 VARIHEAT is connected to the mains supply via an isolator and the isolator is energised, the MAINS light on the side of the electric box will illuminate indicating mains ON and time clock will start to run. The time clock has a battery reserve fitted which when charged will run for 00 hours so that isolating the machine for short periods will not affect the time clock settings. The SERIES 3 VARIHEAT unit is switched on to normal operation by an ON (I)/OFF (O) switch on the control panel. When switched on the red indicator light will illuminate and digital controllers will light up. Note digital water controller will be the only controller to light up when in economy mode. Providing that the controls are set to the correct parameters; nominally 60% RH, 8ºC air temperature, 6ºC water temperature and fresh air switch set to AUTO, then the machine will operate automatically. The unoccupied temperature is set on the digital air controller and will be switched at the time set on the time clock. As the unit operates, the indicator lights will show the state of the control conditions, ie dehumidification, heat to air and heat to water. Other indicator lights are :- Yellow for Fault (high or low refrigerant trip or soft start fault if fitted). Yellow for Defrost Green to indicate automatic operation. See section 3.0 for control panel symbols. PARAMETER CONTROLLERS Each parameter, Relative Humidity, Water Temperature and Air Temperature is sensed within the machine and the signal is taken to the relevant digital controller. RH & Water Temperature controllers have two switching channels, also the Air Temperature controller for AA units without room heating: OUT which is set from the front panel, OUT which is factory pre-set. The Air Temperature digital controller for units with room heating has three switching channels, one of which is for setting OCCUPIED/UCCUPIED air temperature. Each channel has a switching differential which is also factory pre-set. None of the factory settings should be tampered with. When the re-settable channel is adjusted all other settings and differentials automatically follow at the correct relationship. Nominal set point values & diffs RH% = 60% diff 3% Air temperature = 8ºC diff 0.5 ºC Water temperature = 6ºC diff 0. ºC Please note: on AA machines with no fresh air box or RCU, in occupied mode dehumidification stops once the Air temperature is.5ºc above set point. TIME CLOCK The time clock setting determines the OCCUPIED/UCCUPIED periods and is set to match the operators requirements regarding opening and closing times for the pool and possible times where the pool is covered. The two settings are OCCUPIED or day time, and UCCUPIED or night time (covered). The most obvious action of this change is to lower the pool hall air temperature to a determined level to conserve air heating energy. This lowering of temperature is allowable because of the quiescent, and ideally covered, condition of the pool. Pool water occupied = (no pool cover) Pool water unoccupied O = (pool covered) Page 5 SD37360 SUE

8 .0 INSTALLATION SITING, MACHINE LOCATION TOP OUTLET RANGE BOTTOM OUTLET RANGE AIR OFF ELECTRICAL ACCESS PANEL (IF T DUCTED) ALTERNATIVE AIR OFF POSN'S ELECTRICAL ACCESS PANEL ELEC BOX ASSY WATER CONNECTIONS AIR FILTER ACCESS PANEL AIR ON ELECTRICAL ACCESS PANEL ELEC BOX ASSY AIR FILTER ACCESS PANEL AIR ON ALTERNATIVE AIR OFF POSN'S (IF T DUCTED) WATER CONNECTIONS SERVICE ACCESS AREA REQD FOR ALL S AIR OFF HORIZONTAL RANGE ALTERNATIVE AIR OFF POSN' ELECTRICAL ACCESS PANEL ELEC BOX ASSY AIR OFF BOILER WATER IN 3/" BSPM AW600/900 " BSPM ON AW00/500 BOILER WATER OUT 3/" BSPM AW600/900 " BSPM ON AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON ALTERNATIVE AIR OFF POSN' If unit is located in a plant room at pool hall air temperatures, any ambient air ducting must be heavily insulated. Recommend fresh air/exhaust spring return dampers to be fitted to ductwork for sub zero ambient applications in case of power failure. IMPORTANT and 900 models are fitted with constant flow fans and deliver the optimum airflow, self compensating for pressure differentials in the system. On 00 and 500 models ensure duct work pressure drop does not exceed resistance given in data sheet. Damper plates fitted on side of fan CAN be removed if ducting is fitted but fan amps MUST be verified to be as per data sheet fan amps with dry coils, clean air filter and all panels fitted. Page 6 SD37350 SUE

9 .0 INSTALLATION WITH OPTIONAL FEATURES TOP OUTLET RANGE AIR OFF BOTTOM OUTLET RANGE SPIGOT DAMPER SERVICE PANEL OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (5mm DIA) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (57mm DIA) BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON OPTIONAL RESTANCE HEATER IN TH POSN' ONLY. BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM SPIGOT DAMPER AIR FILTER ACCESS PANEL AIR ON OPTIONAL RESTANCE HEATER IN TH POSN' ONLY. OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (5mm DIA) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (57mm DIA) SERVICE ACCESS AREA REQD FOR ALL S HORIZONTAL RANGE AIR OFF OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (5mm DIA) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (57mm DIA) SPIGOT ELEC BOX ASSY DAMPER AIR OFF OPTIONAL RESTANCE HEATER IN TH POSN' ONLY. BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON If unit is located in a plant room at pool hall air temperatures, any ambient air ducting must be heavily insulated. Recommend fresh air/exhaust spring return dampers to be fitted to ductwork for sub zero ambient applications in case of power failure. IMPORTANT and 900 models are fitted with constant flow fans and deliver the optimum airflow, self compensating for pressure differentials in the system. On 00 and 500 models ensure duct work pressure drop does not exceed resistance given in data sheet. Damper plates fitted on side of fan CAN be removed if ducting is fitted but fan amps MUST be verified to be as per data sheet fan amps with dry coils, clean air filter and all panels fitted. Page 7 SD37360 SUE

10 MAX AUTO MIN AUTO % RH ºC HUMIDITY AIR TEMP WATER TEMP ºC = AUTO = = MAX AUTO MIN AUTO STAGE = AUTO = =.0 CONSOLE FIXING TOP OUTLET RANGE BOTTOM OUTLET RANGE AIR OFF (IF T DUCTED) ALTERNATIVE AIR OFF POSN'S CONSOLE FIXING PANEL WITH 3 HOLES. ELECTRICAL ACCESS PANEL ELEC BOX ASSY WATER CONNECTIONS AIR FILTER ACCESS PANEL AIR ON ELECTRICAL ACCESS PANEL ELEC BOX ASSY AIR FILTER ACCESS PANEL AIR ON CONSOLE FIXING HOLES (3) ALTERNATIVE AIR OFF POSN'S (IF T DUCTED) WATER CONNECTIONS SERVICE ACCESS AREA REQD FOR ALL S AIR OFF ELECTRICAL ACCESS PANEL ALTERNATIVE AIR OFF POSN' ELEC BOX ASSY HORIZONTAL RANGE AIR OFF CONSOLE FIXING HOLES (3) BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON ALTERNATIVE AIR OFF POSN' REMOVE SCREWS REPLACE SCREWS % RH C C HUMIDITY AIR TEMP WATER TEMP CONNECTING CABLE CONNECTING CABLE POSITION OF CONNECTOR POSITION OF CONNECTOR AFTER ROTATING PANEL NEW POSITION WITH PANEL ROTATED The Variheat 3 is designed with interchangeable service panels. On delivery, a console fixing service panel is fixed in the position shown in the diagrams above. The console for the Variheat 3 will either be attached to the machine above the air filter access panel or located inside the Variheat 3 fan box. The console can be attached to the Variheat 3 as instructed below.. Fix the 3 self tapping screws provided into the 3 holes in the console fixing service panel. (Indicated by a label). Leave a small gap.. The console drops over the screws. Note: It is best to have the console panel close to the electric box, as once the console is fixed to the Variheat 3 the ribbon cable connector supplied with the Variheat 3 needs to be connected between the console and the electric box. The connector on the console is at the bottom. If the console is to sit on a shelf, the back panel on the console can be turned round. Remove the 6 fixings attaching the display to the back panel. Turn the panel round to that the connector points out of the back of the panel and replace the fixings. See sketch above. Page 8 SD37350 SUE

11 MAX AUTO MIN AUTO % RH º C HUMIDITY AIR TEMP WATER TEMP = AUTO ºC = =.0 CONSOLE FIXING, VARIHEAT 3 WITH OPTIONAL FEATURES TOP OUTLET RANGE AIR OFF BOTTOM OUTLET RANGE SPIGOT DAMPER SERVICE PANEL CONSOLE FIXING PANEL WITH 3 HOLES. BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 BOILER WATER OUT 3/" BSPM AW600/900 " BSPM AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON OPTIONAL RESTANCE HEATER SPIGOT DAMPER OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (DIA 5mm) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (DIA 57mm) OPTIONAL RESTANCE HEATER OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT BOILER WATER IN 3/" BSPM AW600/900 " BSPM AW00/500 BOILER WATER OUT 3/" BSPM AW600/900 " BSPM AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON CONSOLE FIXING PANEL WITH 3 HOLES. CONSOLE FIXING PANEL WITH 3 HOLES SERVICE ACCESS AREA REQD FOR ALL S AIR OFF HORIZONTAL RANGE ELEC BOX ASSY SPIGOT DAMPER OPTIONAL FRESH AIR MODULE WITH TWO SPIGOTS (DIA 5mm) OR NEGATIVE PRESSURE BOX WITH ONE SPIGOT (DIA 57mm) AIR OFF CONSOLE FIXING HOLES (3) CONSOLE FIXING HOLES (3) RESTANCE HEATER BOX BOILER WATER IN 3/" BSPM AW600/900 " BSPM ON AW00/500 BOILER WATER OUT 3/" BSPM AW600/900 " BSPM ON AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR ON The Variheat 3 is designed with interchangeable service panels. On delivery, two console fixing service panels are fitted in the positions shown in the diagrams above. The console for the Variheat 3 will be inside the Variheat 3 fan box. Attach the console to the Variheat 3 console fixing panel selected as instructed below.. Fix the 3 self tapping screws provided into the 3 holes in the console fixing service panel. (Indicated by a label). Leave a small gap.. The console drops over the screws. Note: It is best to have the console panel close to the electric box, as once the console is fixed to the Variheat 3 the ribbon cable connector supplied with the Variheat 3 needs to be connected between the console and the electric box. The connector on the console is at the bottom. See the sketch on the previous page for instructions on how to rotate the console back panel. Page 9 SD37360 SUE

12 . PLUMBING POOL WATER The Calorex SERIES 3 VARIHEAT should be connected as shown in section 3.0. If an existing heater is being retained then the VARIHEAT should be connected between the filter and the existing heater. Pool water connections on the machine are BSPM stubs. The unit is supplied with off each of the following PVC fittings - BSPFx M F x ½ M ½ x 50mm F Suitable breakable couplings, isolation, and drain down valves should be installed in the pool water inlet/outlet pipes local to VARIHEAT unit. The heat exchanger in the VARIHEAT unit will, on small pools, take the full flow rate of the recirculation system. On larger pools a bypass or separate auxiliary pump may be necessary. This method can also be used to reduce energy consumption, by the installation of a two speed or auxiliary pump by-passing the main pump/filter to satisfy pool water heating and dehumidification without the need for the main pump to be running. When the pipework installation is complete the circulating pump should be switched on and the system checked for leaks. Also check the filter gauge to see that there is not excessive back pressure. CONDENSATE DRAIN The condensate driptray in the VARIHEAT unit collects the water removed by the dehumidification process, It is therefore necessary to ensure that the VARIHEAT unit is placed on a level plinth so that the condensate can run away and not overflow the edges of the driptray inside the machine. All SERIES 3 VARIHEATS have a 3/ BSPM threaded condensate drain connection. The drain pipe should run away with adequate fall to waste ie / per foot min. and must incorporate a U trap & tun dish. BOILER PLUMBING The boiler connections on the machine are :- 3/ BSPM on AW600/900 BSPM on AW00/500 for connecting the boiler water flow and return. Suitable breakable couplings, isolation, and drain down valves should be installed in the boiler water flow and return pipes local to the VARIHEAT unit. Water and air LPHW circuits internal to Calorex Heat Pump should be bled for air pockets. (Bleed valves fitted to unit). Refer to the boiler manufacturers instructions before designing the pipework system. IMPORTANT GENERAL CONDITIONS. Do not route water pipes across service access panels or air inlet/outlets.. The water circuits to and from the VARIHEAT unit should be capable of maintaining the specified water flow limits required by the machine. 3. All pipe work must be adequately supported with allowance for expansion and contraction especially with regard to the plastic pipe work.. It is recommended that when installing water systems the last connections to be made should be adjacent to the VARIHEAT unit to avoid undue stresses on the unit connections. 5. All pool purifying devices and chemical injection systems must be fitted down stream of the VARIHEAT unit with a non-return valve to prevent concentrated chemicals back feeding into the heat exchangers. 6. The practice of dosing chemicals direct into skimmer basket must not be allowed as this would result in concentrated corrosive liquids passing over vulnerable metal components. 7. Water quality must be maintained not only relating to solids, etc but for ph between , and if pool water is saline at a maximum concentration of 8mg/litre. 8. See Warranty Exclusions section 6.0 for total list of water quality limits. Page 0 SD37350 SUE

13 . DETERMINING WATER FLOW Flow Meter Method (see pool water schematics) Ensure isolation valves A and B and bypass valve C are fully open. Slowly close down bypass valve C until correct flow rate is shown on the flow meter (see section.0). Remove handle and lock off valve C. Differential Pressure Method By simply installing two filter pressure indicating gauges, one on the inlet and one on the outlet of the heat pump, and a locking type gate bypass valve in the bypass line, the flow rate through the heat pump can be accurately determined by the difference in the readings of the gauges. This pressure drop is proportional to flow. Flow rate should be set at the maximum differential with a clean filter fitted, this differential pressure will drop as the filter becomes dirty. Provided the filter is cleaned before the minimum differential is reached then no problems should be encountered (standard system only) Setting up the differential When the installation is complete, the procedure for setting the flow rate through the heat pump using two gauges is as follows :-. With the heat pump switched off, ensure isolation valves A, B and bypass valve C are fully open.. Switch on water circulating pump. 3. Note the water system pressure on both gauges - they should read the same, but because of manufacturing tolerance they may read different. For example :- with a water system pressure of 5mhd the gauge on the inlet may read 5 and the outlet gauge 5.5 therefore there is a static error difference of 0.5mhd.. Gradually close the bypass valve C until there is a difference in pressure between the two gauges that is equal to the required pressure drop (see section.0) observing any static error on the gauges before beginning this process. 5. Lock the bypass valve, or render it tamper proof when correct setting is achieved. 6. See section.0 for correct pool water pressure drop. Page SD37360 SUE

14 POOL WATER SCHEMATIC (STANDARD) ENSURE POOL FILTRATION PUMP SELECTION ALLOWS FOR ALL SYSTEM RESTANCE POOL SANITIZER OR CHEMICAL DOSING POSITION AFTER CALOREX AUX HEATER IF FITTED CALOREX FLOW SETTING FLOW METER METHOD OLATING VALVE A FLOW SETTING PRESSURE GAUGES METHOD OLATING VALVE B PUMP FILTER N RETURN VALVE OR LOOP VALVE C BYPASS VALVE (LOCKING GATE VALVE TYPE) POOL WATER SCHEMATIC (FILTER DOSING) ENSURE POOL FILTRATION PUMP SELECTION ALLOWS FOR ALL SYSTEM RESTANCE AUX HEATER IF FITTED POOL CALOREX FLOW SETTING FLOW METER METHOD N RETURN VALVE OR LOOP FLOW SETTING PRESSURE GAUGES METHOD OLATING N RETURN VALVE VALVE A OR LOOP OLATING VALVE B PUMP BYPASS VALVE C (LOCKING GATE VALVE TYPE) FILTER SANITIZER OR CHEMICAL DOSING POSITION BEFORE FILTER Page SD37350 SUE

15 .3 WATER CONNECTIONS (also see SECTION.) BOILER WATER IN 3/" BSPM AW600/900 " BSPM ON AW00/500 BOILER WATER OUT 3/" BSPM AW600/900 " BSPM ON AW00/500 POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR FILTER ACCESS PANEL POOL WATER OUT " BSPM DRAIN 3/" BSPM POOL WATER IN " BSPM BOILER WATER OUT 3/" BSPM AW600/900 " BSPM ON AW00/500 BOILER WATER IN 3/" BSPM AW600/900 " BSPM ON AW00/500 MAINS IN 5mm DIA MAINS IN 5mm DIA MACHINE WITH STANDARD FITTINGS MACHINE WITH FITTINGS REVERSED COPPER STUB VH3 DRAIN CUSTOMERS "TUN DH" VH3 UNIT DRAIN TO WASTE U TRAP BOILER WATER SCHEMATIC INTERNAL 3 WAY MOTORED VALVE (DIVERTING) CONTROLLED BY VARIHEAT. SERIES 3 VARIHEAT CABINET BOILER FLOW BALANCE VALVE (FACTORY SET) PUMP RADIATORS IF FITTED FLOW METER LPHW CONNECTIONS Page 3 SD37360 SUE

16 . ELECTROLYTIC CORROSION IN SWIMMING POOLS Electrolytic corrosion will occur when dissimilar metals that are in contact with each other create a potential difference between themselves. Sometimes separated by a conductive substance known as an electrolyte, the dissimilar metals will create a small voltage (potential difference) that allows the ions of one material to pass to the other. Just like a battery, ions will pass from the most positive material to the more negative material. Anything more than 0.3 volts can cause the most positive material to degrade. A swimming pool with its associated equipment can create this effect. The pool water being an ideal electrolyte and components of the filtration circuit, heating system, steps, lights etc providing the dissimilar metals needed to complete the circuit. Whilst these small voltages are rarely a safety threat, they can create premature failure through corrosion. Not dissimilar to corrosion through oxidation, electrolytic corrosion can cause complete failure of a metallic material in a very short period of time. In order to prevent this type of corrosion all metallic components in contact with swimming pool water should be bonded together using 0mm² bonding cable. This includes non-electrical items such as metal filters, pump strainer boxes, heat exchangers, steps and handrails. It is highly recommended that bonding be retrofitted to existing pools, which may not be protected by this system. Page SD37350 SUE

17 .5 ELECTRICAL INSTALLATION ELECTRICAL SAFETY It is important to ensure that all aspects of the installation comply with the latest I.E.E. Regulations. It is also important to ensure that any remote devices which terminate within the pool hall are of the type and voltage as specified in the latest I.E.E. Regulations. The machine should be installed in accordance with EMC00/08/EC. PROTECTED SUPPLY Whilst not mandatory, Calorex recommend that an R.C.C.B. is always fitted or that the supply is to local electricity authority recommendations, and that all ducting is bonded in accordance with these regulations. The supply to the machine should incorporate fuses or motor rated circuit breakers (type GU, FAZC) to specified rating (see data sheet) H.R.C. fuses are recommended. An isolator must be fitted within clear view of the machine and not more than metres away. The isolator must have a minimum of 3mm air gap when in the off position. INCONSTENT ELECTRICAL SUPPLY. The following limits of operation must not be exceeded if Calorex machines are to be guaranteed either in performance or warranty terms :- Voltage single phase - 07V min, 53V max Voltage three phase - 360V min, 0V max Frequency - 7.5Hz min, 5.5Hz max. N.B The voltage must be measured at the heat pump mains terminals with all the fans/compressors running at the rated condition. Please note that AW00/500 three phase machines are fitted with a phase rotation relay and will not run if the phases are connected incorrectly or if the voltage is 5% less than 00V (30V) for a three phase 50Hz machine CORRECT CABLE SIZING The cable supplying electricity to a machine with a given load must increase in cross sectional area (CSA) as the length increases in order that the voltage drop within the cable does not exceed recommended limits. Cable sizing should be calculated by an approved electrician with due consideration to I.E.E. and local codes of practice. If resistance heaters are fitted an extra power supply will be required to the terminal blocks inside the heater box, see data sheet for supply amps and fuse size. FOR ACCESS TO MAINS TERMINAL BLOCKS, ETC ELEC BOX ASSY DRAIN 3/" BSPM AIR FILTER ACCESS PANEL MAINS IN 5mm DIA off Page 5 SD37360 SUE

18 .5. MAINS SUPPLY TERMINAL BLOCK LAYOUT SINGLE AND THREE PHASE ( CONNECTION TO TERMINALS AND 5 ON SINGLE PHASE UNITS) LINK WIRES NECESSARY IF TERM'S 6 TO 9 T IN USE E N L L L3 E N L N 3 5 G H I J VOLT FREE MACHINE ON VOLT FREE MAIN FAN RUN BOILER DEMAND POOL PUMP START REMOTE OCC/UCCUPIED REMOTE ON/OFF. (SEE TE 'a' ) RCU (IF FITTED) FAN CONT' FAN CYCLE FAN COMMON SOFT START LINK MIN DAMPER MOTOR, LOCATED ON FRESH AIR BOX COMMON MAX AMBIENT STAT, OPENS ON LOW TEMP (IF FITTED) RESTANCE HEATER ASSY RCU SOL VALVE A RCU SOL VALVE B COMMON RCU CONTROL UNIT RESTANCE HEATER FAN STAT ELECTRIC BOX TERMINAL RAIL LOAD L N OPTIONS IF TH FACILITY USED TIME CLOCK (IF FITTED) MUST BE SET TO UCCUPIED REMOTE OCC/UCCUPIED SEE TE SECTION.5. POOL PUMP START SEE TE SECTION.5. SWITCHED FUSED OLATOR TO BE WITHIN SIGHT OF FRONT OF UNIT & T MORE THAN M AWAY N L L L3 SWITCHED FUSE OLATOR SEE DATA SHEET FOR RATINGS LOAD TE 'a' LINK THESE TERMINALS WHEN REMOTE T REQUIRED REMOVAL OF LINK WILL STOP FAN, COMPRESSOR & DIGITAL CONTROLLERS. L N BOILER DEMAND SEE TE 3 SECTION.5. TERMINALS I & J VOLT FREE MAIN FAN RUN TERMINALS G & H VOLT FREE MACHINE ON TERMINAL BLOCK UNDER FLANGE IN ELECTRIC BOX OPTIONAL REMOTE SENSOR BOX HUMIDITY SENSOR AIR PROBE P5 P6 P7 P3 P TERMINALS IN REMOTE SENSOR BOX SEPARATE MAINS SUPPLY TERMINAL BLOCKS FOR RESTANCE HEATER BOXES LAYOUT SINGLE AND THREE PHASE ( CONNECTION TO TERMINALS L AND L3 ON SINGLE PHASE UNITS) 3 5 EARTH STUD 3 5 E LLL3 MCB CUSTOMER TERMINATIONS TO HEATER BOX SEE TE SECTION.5. Page 6 SD37350 SUE

19 .5. TES ON TERMINAL BLOCK CONNECTIONS TE - Remote occupied/unoccupied These contacts (from terminals 0 & ) are to enable the air temperature set back facility to be remotely overridden. Please note that in unoccupied mode on AW machines, water heating does not take place unless there is a demand for dehumidification. There is a Vac output from these terminals and closing a remote switch will enable the unit to regain the normal operating air temperature for when the pool is in use. This can be done via a voltage free pool cover switch or some other form of voltage free switch. If this facility is used then the time clock (if fitted) on the control panel of the unit should be set to the unoccupied (o) position. (See note on time clock and switch settings, section 3..). If these terminals are fitted on versions without time clocks then they MUST BE LINKED. TE - Pool pump start -AW only (see also section 3..) These are voltage free contacts (from terminals 8 & 9) rated at 3() Amp at 30 Volts. If the pool water pump is to be run via an external time clock then these connections should go across the switching contacts of the external time clock to ensure that, if dehumidification demand occurs the pool water pump will start. The pool water pump will exceed the one amp inductive rated current of these contacts therefore a contactor or relay should be used to switch the load of the pump.the switching action of the external time clock should energise the contactor/relay coil. If the pool water pump is to be run continuously then these contacts can be ignored. TE 3 - Boiler demand -AA+LPHW & AW machines only These are voltage free contacts (from terminals 6 & 7) rated at 3() Amp at 30 Volts. If the low pressure hot water supply to the unit is to be governed by the Calorex unit then these contacts should be utilised to bring water to the unit via the boiler, motorised valve, boiler pump etc. Remember the maximum inductive load is one amp. This is dependant on how the low pressure hot water supply to the unit has been designed. If the supply of low pressure hot water to the unit is not dependant on a signal from the unit then these contacts can be ignored. TE SEPARATE SUPPLY FOR RESTANCE HEATER BOX If resistance heaters are fitted then an extra power supply will be required to the terminal blocks inside the heater box. See section.0 for supply amps & fuse size. CONTROL PANEL 5 WAY CABLE CONNECTION Data signal between control panel and electric box is via a 5 way cable with D connection (plug & socket) both ends. Page 7 SD37360 SUE

20 .6 CIRCUIT DIAGRAMS ELECTRICAL CONTROL & POWER CIRCUIT AW VERSION LINK FOR RMAL RUN (BREAK TO STOP M/C) L3 L L PHASE ROTATION FOR AW00 & 500 SEE BELOW CONTROL MCB REMOTE ON/OFF 3 F.5A F A D D ON/OFF SWITCH ECOMY SWITCH N/C RCU RCU MCB RELAY (if fitted) 6 RCU 9 R 6 MAINS LAMP 7 FUSE A REMOTE DAMPER RELAY FOR USE WITH FROST PROTECTION KIT (IF FITTED) FKR B A COMPRESSOR AUX CONTACTOR N/C 0V HUMIDITY SENSOR P7 P6 v v TRANSFORMER V AC 8 PROBE CONTROL POWER LAMP D6 P P D7 D7 R OUT WATER STAT' OUT RING FALLING AIR AIR/WATER SWITCH D3 H G R D PRIORITY VOLT FREE SWITCH 9 3 R3 M/C ON 7 COMP 0 AUX 3 R8 D N/O WATER HEATING 60min TIMER 3 5 V AC D R 7 COMP AUX 3 N/O R9 TB:L TB:N 58 TO REMOTE TO BOILER DEMAND TERMINALS POOL PUMP R DAMPER IF FITTED. CRANKCASE HEATER 6 7 LPHW MICRO SWITCHES REVERSING VALVE v WATER LPHW VALVE v 6 N 7 N AW00 & 500 ONLY CONTROL PHASE MCB ROTATION L3 L RELAY TO N TRANSFORMER L POWER CIRCUIT SINGLE PHASE L 5 CONTROL CIRCUIT TES BREAKER A COMPRESSOR CONTACTOR Aux NC RCU CIRCUIT BREAKER 5A TO RCU RELAY CONTROL CIRCUIT BREAKER A (A WHEN FRESH AIR BOXFITTED) FAN CIRCUIT BREAKER COMPRESSOR CIRCUIT BREAKER 'R' LETTER RELAY'S ARE v 'RE' LETTER RELAY'S ARE 30v N CONTROL CIRCUIT 6 'P' LETTERS ARE CONNECTOR BLOCK PIN NUMBERS 5 = DIN RAIL MOUNTED TERMINAL BLOCK NUMBERS FAN CONTACTOR A A 3 5 COMP CONTACTOR D5 = 5 WAY 'D' PLUG PIN NUMBERS 6 A 6 IF REMOTE OCC/UCC FEATURE USED a) FORCE TIME CLOCK TO 'UCCUPIED' b) 0/ N/O = 'UCCUPIED c) 0/ N/C = 'OCCUPIED' A TIMER 3 7 RES' HEATER CONTROL IF FITTED TO TB 38 TO RE(A) RUN 9 CAPACITOR 8 W(C) V(S) U(R) COMPRESSOR L N FAN MOTOR 3 N/C N/C N/C VH3 MK II AW CIRCUIT D59850 S N/O N/O N/O COM COM COM 0 COIL MODEL AA/AW600AVHX(F) AA/AW900AVHX(F) AA/AW00AVHX(F) FAN MCB PHASE 0A 0A 6A COMP MCB DEVICE VALUE 6A 0A 3A STANDARD RELAY FORMAT Page 8 SD37350 SUE

21 .6 ELEC CONTROL & POWER CIRCUIT AW VERSION CONTINUED REMOTE OCC/UCC T LINKED FOR RMAL RUN SEE TE LINK IF REMOTE CONTROL FITTED 0 D P5 0-0VDC + D0 P6 P7 SUPPLY V 3 PROBE GRND 0V - D8 P3 P D9 TIME CLOCK RTRONICS <PALADIN> AIR SENSOR R/H TERMINALS VARY WITH MANUFACTURER AIR HEATING OUT 9 FALLING 0 D D5 7 R 3 3 AIR STAT' OUT FALLING 3 OUT3 7 RING 8 D6 8 R 5 <3> 3 M <> <> UCCUPIED D5 0 0 R R3 OCCUPIED OUT HUMIDITY STAT' RING RING 5 6 D8 0 R5 7 D3 OUT 3 MAX AUTO MIN DEHUM LAMP D0 D 9 30 R RCU N/O L H 7 C HP SWITCH H C LP SWITCH L R N/O A RE 30v B 9 FAN CONT' FAN 33 CYCLE 3 FAN COM' 5 6 RESTANCE HEATER ASSY CONTACTOR THERMAL CUTOUTS FAN CONTACTOR 0 7 R 3 D A 6 AIR LPHW VALVE 30v A R (RCU) LPHW FROST PROTECTION STAT OPENS ON LOW TEMP (IF FITTED) () () P() FAN SPEED CONTROLLER 0V 3 0V FAN MOTOR +0V Vsp GND DAMPER EARTH MOTOR N L LINK IF STAT T FITTED L Lo N L Lo N T.B. EARTH 9 R 6 AUTO LAMP MAX 5 MIN 3 3 POSN CHANGEOVER SWITCH CENTRE OFF DAMPER FRESH AIR BOX D 3 RE3 N/C 7 R3 3 0 D5 FAULT LAMP R D R7 7 A 9 7 RE6 3 A DEFROST LAMP SOFT START IF FITTED OR LINK RE min TIMER COMPRESSOR A A FAN CONTACTOR A A 37 0 DF SOLEID DEFROST VALVE STAT RE B A 9 RE 30V 6 3 A 7 B J I VOLT FREE MAIN FAN RUNNING 55 RESTANCE HEATER FAN STAT R FRESH AIR BOX (IF FITTED) 7 N A B POWER CIRCUIT 3 PHASE WITH SINGLE PHASE FAN POWER CIRCUIT 3 PHASE WITH 3 PHASE FAN RCU SOL' VALVES L3 L3 L L L L 3 5 RCU CIRCUIT BREAKER 5A CONTROL CIRCUIT BREAKER A (A WHEN FRESH AIR BOX FITTED) TO RCU RELAY CONTROL CIRCUIT MAIN FAN CIRCUIT BREAKER 6 COMPRESSOR MOTOR STARTER (MCB) 6 RCU CIRCUIT BREAKER 7A CONTROL CIRCUIT BREAKER A (A WHEN FRESH AIR OPTION INSTALL ED) MAIN FAN CIRCUIT BREAKER 3 5 COMPRESSOR MOTOR STARTER (MCB) 6 N TO RCU RELAY CONTROL CIRCUIT 6 N FAN CONTACTOR A A COMP A 3 5 CONTACTOR 6 FAN A A 3 5 COMP CONTACTOR 3 L N FAN MOTOR RES' HEATER CONTROL IF FITTED TO TB 38 TO RE(A) A TIMER S C R COMPRESSOR CONTACTOR 6 FAN MOTOR A TO TB 38 TIMER RES' HEATER CONTROL IF FITTED TO RE(A) C A S R COMPRESSOR U(R) V(S) W(C) COMPRESSOR SANYO COMPRESSOR ONLY MODEL AA/AW600BVHX(F) 0A AA/AW900BVHX(F) 0A FAN MCB PHASE COMP MCB TRIPPING CURRENT SETTING VALUE.6A 3.8A 6.7A 5.6A AA/AW00BVHX(F) 6A 0.5A 8.8A MODEL FAN MCB 'F' N 'F' AA/AW500BVHX(F) 3.0A.A COMP MCB TRIPPING CURRENT SETTING VALUE.A.0A Page 9 SD37360 SUE

22 ELECTRICAL CONTROL CIRCUIT AA+LPHW VERSION See pages AW circuit for power circuits LINK FOR RMAL RUN (BREAK TO STOP M/C) L3 PHASE ROTATION FOR AW00 & 500 SEE BELOW REMOTE ON/OFF 3 F.5A ON/OFF SWITCH L CONTROL MCB D L F A D RCU MCB (if fitted) FUSE A COMPRESSOR AUX CONTACTOR N/C HUMIDITY SENSOR P7 P6 v v CONTROL POWER LAMP R 7 3 REMOTE DAMPER RELAY FOR USE WITH FROST 0 D7 RCU RELAY 9 R 6 7 PRTOTECTION KIT (IF FITTED) FKR B V AC H G VOLT FREE M/C ON 6 RCU 5 MAINS LAMP A 0V V AC 8 D D3 R R TB:L 57 TB:N 58 TO REMOTE DAMPER IF FITTED. CRANKCASE HEATER TRANSFORMER TO BOILER DEMAND TERMINALS 6 7 LPHW MICRO SWITCHES (IF FITTED) 5 RESTANCE HEATER ASSY CONTACTOR THERMAL CUTOUTS FAN CONTACTOR 3 D A A 6 AIR LPHW VALVE 30v N N TES 'R' LETTER RELAY'S ARE V 'RE' LETTER RELAY'S ARE 30V 'P' LETTERS ARE CONNECTOR BLOCK PIN NUMBERS 5 = DIN RAIL MOUNTED TERMINAL BLOCK NUMBERS D5 D = 5 WAY 'D' PLUG PIN NUMBERS = DELAY TIMER IF REMOTE OCC/UCC FEATURE USED a) FORCE TIME CLOCK TO 'UCCUPIED' b) 0/ N/O = 'UCCUPIED c) 0/ N/C = 'OCCUPIED' VH3 MK II AA + LPHW CONTROL CIRCUIT D5985 S 7 Page 0 SD37350 SUE

23 .6 ELEC CONTROL CIRCUIT AA+LPHW CONTINUED REMOTE OCC/UCC T LINKED FOR RMAL RUN SEE TE LINK IF REMOTE CONTROL FITTED 0 D P5 0-0VDC + D0 P6 P7 SUPPLY V 3 PROBE GRND 0V - 5 D AIR HEATING TIME AIR SENSOR R/H CLOCK RTRONICS TERMINALS VARY D8 P3 P D9 <PALADIN> WITH MANUFACTURER DEHUM 5 <3> LAMP R AIR STAT' RCU M <> OUT OUT OUT OUT OUT3 HUMIDITY 7 <> AIR HEATING N/O 9 9 STAT' FALLING RING RING RING ONLY R FALLING UCCUPIED OPTIONS N/O R N/C 6 D0 9 D5 7 C D8 D5 HP A 7 OPTIONS OVER SWITCH RE 7 AIR HEATING H 0 30v R L D6 R5 B 30 C 8 LP 0 7 SWITCH R R D3 D H L SOFT START POSN CHANGEOVER IF FITTED SWITCH CENTRE OFF RE3 OR LINK 0 0 DAMPER FRESH AIR BOX R D N/C RE R (RCU) R AUTO 0 D5 DEFROST LAMP STAT LPHW FROST PROTECTION LINK IF STAT R6 STAT OPENS ON LOW TEMP D 38 T FITTED (IF FITTED) 9 7 TIMER MAX () () 5 RE P() B 0 AIR HEATING ONLY R OPTIONS OCCUPIED FAN SPEED CONTROLLER R7 0V 3 0V 7 FAN MOTOR MAX AUTO MIN FAULT LAMP DEFROST LAMP COMPRESSOR A A FAN CONTACTOR A A 7 A J I FAN CONT' 3 FAN 33 CYCLE 3 FAN COM' 37 DF SOLEID VALVE 3 39 A 9 RE 30V 6 3 B 55 RESTANCE HEATER FAN STAT R V Vsp GND EARTH N L DAMPER MOTOR FRESH AIR BOX (IF FITTED) L Lo N L Lo N T.B. EARTH MIN A RE6 A N A B RCU SOL' VALVES See AW circuits for power circuits Page SD37360 SUE

24 ELECTRICAL CONTROL CIRCUIT AA VERSION See pages AW circuit for power circuits L3 PHASE ROTATION FOR AW00 & 500 SEE BELOW REMOTE ON/OFF LINK FOR RMAL RUN (BREAK TO STOP M/C) ON/OFF 3 SWITCH F.5A L CONTROL MCB D L F A D RCU MCB (if fitted) COMPRESSOR AUX CONTACTOR N/C HUMIDITY SENSOR P7 P6 v v R 0 OPTIONS ONLY CONTROL POWER LAMP R D7 AIR HEATING OUT FALLING 8 9 AIR STAT' PROBE D8 P3 P D9 0 OUT RING RCU RELAY 9 R 6 V AC H G 0 D D5 D6 3 6 RCU 5 MAINS LAMP 0V TRANSFORMER V AC D3 8 D VOLT FREE M/C ON R R 0 R OPTIONS R R (RCU) CRANKCASE HEATER FAN SPEED CONTROLLER 0V 3 0V 5 FAN MOTOR +0V Vsp GND EARTH N L DAMPER MOTOR L Lo N FRESH AIR BOX (IF FITTED) 6 N N TES 'R' LETTER RELAY'S ARE V 'RE' LETTER RELAY'S ARE 30V 'P' LETTERS ARE CONNECTOR BLOCK PIN NUMBERS 5 = DIN RAIL MOUNTED TERMINAL BLOCK NUMBERS D5 D = 5 WAY 'D' PLUG PIN NUMBERS = DELAY TIMER IF REMOTE OCC/UCC FEATURE USED a) FORCE TIME CLOCK TO 'UCCUPIED' b) 0/ N/O = 'UCCUPIED c) 0/ N/C = 'OCCUPIED' VH3 MK 'AA' CONTROL CIRCUIT D5985 iss 6 Page SD37350 SUE

25 .6 ELEC CONTROL CIRCUIT AA CONTINUED LINK IF REMOTE CONTROL FITTED D P5 0-0VDC + D0 P6 P7 SUPPLY V GRND 0V - AIR SENSOR R/H TERMINALS VARY WITH MANUFACTURER OUT RING HUMIDITY STAT' RING OUT DEHUM LAMP R RCU N/O 7 R D8 0 R5 6 7 D3 MAX 3 AUTO MIN OPTIONS R N/C D0 9 7 OPTIONS ONLY L 30 D H C HP SWITCH H C LP SWITCH L N/O A RE 30v B FAN CONT' FAN 33 CYCLE 3 FAN COM' R POSN CHANGEOVER SWITCH CENTRE OFF DAMPER FRESH AIR BOX D FAULT LAMP RE3 N/C 7 3 SOFT START IF FITTED OR LINK RE MAX 5 MIN AUTO LAMP D R7 0 R6 D DEFROST LAMP R3 7 6 D TIMER COMPRESSOR A A 3 FAN CONTACTOR 37 0 DF SOLEID DEFROST VALVE STAT 3 38 RE A B A A 7 RE 30V 39 A B 7 8 R (RCU) 5 L Lo N A RE6 J I T.B. EARTH 3 A 6 N A B RCU SOL' VALVES See AW circuits for power circuits Page 3 SD37360 SUE

26 .7 REGULAR PLANNED MAINTENANCE Operations to be carried out during a regular planned maintenance visit are as follows:. Replace all belts where fitted.. Clean or replace filters as applicable. (This action may be required more frequently than regular servicing. 3. Check operation and condition of all fans and compressors.. Check capacitor tolerances (where fitted). 5. Check condition of all heat exchangers/evaporators. 6. Check refrigeration system parameters. 7. Check operation of control valves. 8. Check for water leaks. 9. Check drip trays and internal drain lines for blockages and clear. 0. Check operation of controls and calibrate as necessary.. Check operation of interlocks in use.. Final check on overall operation of unit. 3. Indicate on report any faults found or causes for concern. Frequencies recommended: Light to medium use Heavy use visits per year. visits per year. Page SD37350 SUE

27 3.0 CONTROLS STANDARD CONTROL PANEL MODULE (V) ECOMY SWITCH AIR/WATER SWITCH see note a below see note a below % RH ºC ºC MAX AUTO MIN HUMIDITY AIR TEMP WATER TEMP = AUTO = = AUTO Power on Power off Power symbol Fresh air flow Switch (for fresh air/negative pressure box options only)- - in AUTO position auto indicator light will be on. - in MAX position dampers fully open, light off. - in MIN position dampers closed, light off. ºC ºC Fault light Defrost light Dehumidification light Air heating light Water heating light Pool hall symbol Check that the pool hall air and water flow through the unit are within specified limits. Check M.C.B. s & pressure switches see note b (also soft start overload if fitted) and push all to reset. Call for a service check if fault light stays on. Unit is temporarily defrosting evaporator machine will automatically reset. Indicates that there is a demand for the unit to dehumidify. Indicates that there is a demand for the unit to heat the pool hall air. Indicates that there is a demand for the unit to heat the pool water. Manual override symbol = Pool water occupied (no pool cover) O = Pool water unoccupied symbol (pool covered) Economy Switch Air to Water Switch (AW versions only). Switches between full function, i.e. dehumidification/air & water heating to water heating only. Note that in economy mode there is a 60 minute time delay before water heating commences. (AW versions only). Can be set to give priority to either water heating or air heating. Note a Water temperature display and Economy switch not fitted on AA or AA+LPHW versions, time clock not fitted on AA version. Note b High & low pressure switches are mounted on a cross bracket fitted inside the fridge box assemblies. Push the red button on each switch to reset. Page 5 SD37360 SUE

28 OPTIONAL REMOTE CONTROL PANEL MODULE (V) AIR/WATER SWITCH ECOMY SWITCH See note a section 3.0 HUMIDITY MAX AUTO % RH MIN AIR TEMP ºC = AUTO = WATER TEMP = AUTO ºC AUTO Note - water sensor lead can be extended up to 0 metres with 0,5mm² cable. Also on sensor lead terminal block ( located in electric box assy) terminals P5 & P7 must be linked for this control panel to operate. OPTIONAL REMOTE SENSOR BOX Disconnect wires to sensors at electric box terminals & run leads to sensor box & connect as shown use 0,5mm² cable up to 0 metres. SENSOR PLUG AND TERMINAL BLOCK DCONNECT LEADS TH SIDE & REPLACE WITH REMOTE SENSOR LEADS B LB GR V 0,5 PU W 0,5 P7 P6 P5 P P3 P P SENSOR BOX TERM 5 SENSOR BOX TERM SENSOR BOX TERM 3 SENSOR BOX TERM SENSOR BOX TERM SENSOR/PROBE TB RE RE RE3 R R R3 R P7 P6 P5 P P3 DELAY TIMER 3 5 HUMIDITY STAT AIR STAT R8 R9 R0 DELAY TIMER ELECTRIC BOX Page 6 SD37350 SUE

29 COMMSIONING CHECKLT a. Is the building finished in accordance with the original plans and specification. b. Is the plenum chamber and all ductwork insulated, special attention should be made to the insulation of the exhaust air ducting and fresh air inlet ducting to prevent condensation problems. c. Are there any significant draughts in the pool hall or plant room (plenum installation) through poorly fitting doors, windows, pipe ducts, etc. This will let in unwanted ambient air raising the heating duty required. d. Is fresh air suction and exhaust air discharge ducting (if fitted) perfectly sealed from plant room. TE: (c) and (d) above should be checked by measuring plant room and pool hall air temperatures.if the plant room is acting as a plenum chamber both temperatures should correspond. If the plant room temperature is lower then ambient air is leaking in, this leak should be located and rectified. e. Are the fresh air inlet and exhaust air outlets free from obstructions ie, undersize grilles, objects in the path of exhaust air deflecting it back to the fresh air inlet, etc. f. Is occupied / unoccupied set correctly, (set with air thermostat) see section g. Is the time clock set correctly. h. Is start up ( fresh air flow switch to min ) feature required and if so is customer aware of when to switch machine back to Auto. i. Has the Calorex Heat Pump been bled for air pockets. (Bleed valves fitted to unit as standard). j. Any sign of abnormal operation such as water dripping should be reported immediately to an installer or Calorex. k. Is airflow sufficient through machine? Remove fan damper plates and check fan amps. l. Check belts and filters are fitted correctly TIME CLOCK SETTINGS The time clock is a quartz hour clock with 00 hours battery reserve used to control the automatic operation or the SERIES 3 VARIHEAT unit per hour time cycles. SETTING ACTUAL TIME Turn the large clock hand clockwise until the correct time of day is set, ensuring that the correct half of the day is chosen ( hour clock). 7 SEGMENTS 8 AUTOMATIC AND MANUAL SETTING LEVER 0 A FIG. SETTING FOR AUTOMATIC OCCUPIED/UCCUPIED OPERATION WITH TIME CLOCK To set for automatic time clock control of occupied/unoccupied, slide the lever to A. Each yellow segment represents a 5 minute time period. Extend outward the segments for a period of time that the pool is occupied (i.e. used or uncovered) per day. If the unoccupied period is more than 0 hours per day, extend one segment at 9:00 or other suitable time that does not coincide with the main occupied period*. Page 7 SD37360 SUE

30 SETTING FOR AUTOMATIC OCCUPIED/UCCUPIED OPERATION WITH REMOTE INTERFACE To set for remote control of occupied/unoccupied, slide lever to O. See section., Note for more information on remote interface. If the unoccupied period is more than 0 hours per day, extend one segment at 9:00 or other suitable time that does not coincide with the main occupied period.* Ensure all other segments are pushed inwards and slide lever to A. SETTING FOR MANUAL OCCUPIED/UCCUPIED OPERATION To set for manual occupied period (or override automatic unoccupied period) slide the lever to I for occupied. If the unoccupied period is more than 0 hour per day, to set for a manual unoccupied period slide the lever to O for unoccupied ; extend outwards one segment at 9:00 or other suitable time that does not coincide with the main occupied period* and ensure all other segments are pushed inwards. *In unoccupied mode, the pool water is not heated unless a demand for dehumidification occurs during this period. If the unoccupied is more than 0 hours per day, it is recommended to allow a brief occupied period to allow the water temperature to be sampled and maintained if necessary. 3.. WIRING TO EXTERNAL SWIMMING POOL PUMP/FILTER TIME CLOCK L 9 8 SERIES 3 VARIHEAT. EXTERNAL COMPONENTS TO BE WIRED TO TERMINAL BLOCK LOCATED INSIDE MACHINE ELECTRIC BOX. SEE SECTION. POOL PUMP STARTER CUSTOMERS EXTERNAL PUMP/FILTER TIME CLOCK N Page 8 SD37350 SUE

31 3..3 POOL & AIR TEMPERATURE AND HUMIDITY CONTROLS POOL WATER TEMPERATURE & HUMIDITY DIGITAL CONTROLLERS AND AIR DIGITAL CONTROLLER ON AA MACHINE WITHOUT AIR HEATING To Program the Set Point. Press down P, SP and Set Point value will be displayed alternately. Press the or key to change the value of SP. Once the desired value is displayed press P to memorise the value. The display will revert to the present reading. TE: If anything else shows on the display leave alone for minute until the display returns to normal. AIR TEMPERATURE DIGITAL CONTROLLER AW AND AA MACHINES WITH AIR HEATING The digital controller for controlling air temperature can be changed as follows:- To program the set point, press P button once and release it. SP (set point) and set point value e.g. 8 will be displayed alternately. Press P again AL (-.5) will show. This is the difference between the set point and AL plus a constant 0.5 e.g = ºC (unoccupied) SP and AL can be changed in the same way as described for humidity and air. TE: AL can only be set - to -0 below SP value. If the reading on the digital controller is not the same as the actual pool hall temperature, water temperature or relative humidity it may be necessary to program an offset into the digital controller. See technical manual. FRESH AIR BOX AUTO MAX MIN TE Opens dampers and switches on fan when demand for dehumidification (OUT ) and/or high temperature OUT 3 (OUT on AA version without time clock). Machine must be in occupied mode to close Relay and to bring on fan and open damper motor. Opens dampers and brings on fresh air fan to provide full fresh air at all times, even in unoccupied mode. Turns off fresh air fan and closes dampers to minimum position. On machines with LPHW, if the optional frost protection stat is fitted, the operation of the dampers will be inhibited when the ambient temperature is below 6ºC. NEGATIVE PRESSURE BOX AUTO MAX MIN TE Opens dampers and switches on fan when demand for dehumidification (OUT ) and/or high temperature OUT 3 (OUT on AA version without time clock). Machine must be in occupied mode to close Relay and to bring on fan and open damper motor. Opens dampers to exhaust air from pool hall at all times, even in unoccupied mode. Turns off fresh air fan and closes dampers to minimum position. On machines with LPHW, if the optional frost protection stat is fitted, the operation of the dampers will be inhibited when the ambient temperature is below 6ºC. Page 9 SD37360 SUE

32 .0 DATA SHEET SERIES 3 VARIHEAT MODEL:- Units AA/AW600 AA/AW900 AA/AW00 AA/AW500 DEHUMIDIFICATION DUTY HEAT TO AIR VIA HEAT PUMP (30ºC/60% rh) litres/hr ºC dewpoint (summer if fresh air option fitted) litres/hr ºC dewpoint (winter if fresh air option fitted) litres/hr VIA HEAT PUMP (MODE A):- kw VIA HEAT PUMP (MODE B):- kw VIA SINGLE 80ºC :- kw TOTAL :- (MODE B) kw VIA DOUBLE 80ºC :- kw 8, VENTILATION HEAT REQ' FOR FRESH -5 º C(IF OPTION *FITTED) kw HEAT TO POOL WATER (AW VERSIONS) RECOMMENDED BOILER CAPACITY (AW VERSIONS) RECOMMENDED BOILER CAPACITY (AA+LPHW) ELECTRICAL MAIN FAN COMPRESSOR GENERAL DATA OPTIONAL FRESH AIR COOLING FEATURE OPTIONAL RESTANCE HEATER MODULE VIA HEAT PUMP (MODE A):- kw VIA HEAT PUMP (MODE B):- kw VIA 80ºC :- kw TOTAL :- kw Flow Rate Pool Water ± 0% l/min Pressure Rated Flow m/hd Max working pressure bar RECOMMENDED BOILER CAPACITY kw FLOW RATE SINGLE CAPACITY LPHW l/min FLOW RATE DOUBLE CAPACITY LPHW l/min Pressure Rated Flow SINGLE CAPACITY LPHW m/hd Pressure Rated Flow DOUBLE CAPACITY LPHW m/hd RECOMMENDED BOILER CAPACITY kw FLOW RATE SINGLE CAPACITY LPHW l/min 0 0 FLOW RATE DOUBLE CAPACITY LPHW l/min Pressure Rated Flow SINGLE CAPACITY LPHW m/hd Pressure Rated Flow DOUBLE CAPACITY LPHW m/hd.6... Max system working pressure bar TOTAL POWER CONSUMED TYPICAL HIGH PRESSURE SYSTEM WITH CONSTANT FLOW FAN kw N/A TYPICAL LOW PRESSURE SYSTEM WITH CONSTANT FLOW FAN kw N/A 'F' & N 'F' kw N/A N/A N/A 5./.66 MIN' SUPPLY CAPACITY (Max F.L.A.) ph N:- amps N/A MIN' SUPPLY CAPACITY (Max F.L.A.) 3 ph N:- ( 'F' & N 'F' FOR 500) amps / MAX' SUPPLY FUSE ph N:- amps 5 3 N/A MAX' SUPPLY FUSE 3 ph N:- ( 'F' & N 'F' FOR 500) amps / 6 AIR FLOW air on filter, wet evaporator) m³/hr 000 ±0% 500 ±0% 3500 ±0% 300 ±0% MAX EXTERNAL STATIC PRESSURE:- (CONSTANT FLOW FAN) SINGLE LPHW mm Wg 33 9 N/A MAX EXTERNAL STATIC PRESSURE:- 'F' & N 'F' SINGLE LPHW mm Wg N/A N/A N/A / MAX EXTERNAL STATIC PRESSURE:- (CONSTANT FLOW FAN) DOUBLE LPHW mm Wg N/A MAX EXTERNAL STATIC PRESSURE:- 'F' & N 'F' DOUBLE LPHW mm Wg N/A N/A N/A.5 / 9.5 DESIGN CONDITION AMPS:- ph N :- amps N/A 3 ph N :- (F & N F FOR 500) amps N/A N/A N/A 3.3 /.3 FLA:- ph N:- amps N/A FLA:- 3 ph N :- (F & N F FOR 500) amps N/A N/A N/A 3.5 /.5 MINAL POWER CONSUMED:- kw LRA:- ph N:- amps N/A RLA:- ph N:- amps N/A SOFT START AMPS ph N:- amps N/A LRA:- 3 ph N:- amps RLA:- 3 ph N:- amps SOFT START AMPS 3 ph N:- amps Hermetic System GAS CHARGE (R07c) AA & AW kg.8 /.8.85 /.0.7 / / 3.0 LPHW battery volume litres WEIGHT approx' (AW un-packed no options):- kg AIR FLOW:- m³/hr MAX EXTERNAL STATIC PRESSURE mm Wg MINAL POWER kw 6 or 6 or or 8 or8 MINIMUM SUPPLY ph N :- amps 30 or or or 80 N/A MINIMUM SUPPLY 3 ph N :- amps 9 or 8 9 or 8 8 or 7 8 or 7 MAX' SUPPLY FUSE (MCB) ph N :- amps 3 or 63 3 or or 00 N/A MAX' SUPPLY FUSE (MCB) 3 ph N :- amps 0 or 0 0 or 0 0 or 30 0 or 30 For accurate application sizing consult CALOREX Heat Pumps Ltd. mm WG = 9.8Pa Boiler not required for AA versions without LPHW. mhd =.psi MODE A = recovered heat biased to pool water (pool water temp not satisfied) L/min=0. gall/min MODE B = recovered heat biased to pool hall air (pool water temp satisfied) R07c Global warming potential (GWP) 77. Page 30 SD37350 SUE

33 AIR LPHW PERFORMANCE This table shows the difference in performance with temperature and waterflow for all LPHWs, single and double capacity. Air LPHW Performance Percentage of performance or temperature difference Standard Duty Point 00% Water On = 8 Celcius Air On 30 Celcius LPHW Water Entering Temperature C 00% Water Flow Page 3 SD37360 SUE

34 5.0 DIMENSION DRAWINGS 600/900 VERTICAL TOP OUTLET VERSIONS TE - FEET (TOP HAT SECTION) CAN BE REMOVED IF REQD ON ALL VERSIONS ( TO REDUCE HEIGHT BY 00mm) ALTERNATIVE AIR OFF POSN'S AIR IN AIR OFF STANDARD MACHINE CONFIGURATION BOILER WATER IN 3/" BSPM BOILER WATER OUT 3/" BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL CONSOLE FIXING 8.00 FIX CONSOLE TO CONSOLE MOUNTING SERVICE PANEL OR MOUNT REMOTELY (SEE SECTION ) 7.00 MAINS IN THRO' DIA 5mm off RESTANCE HEATER (IF FITTED) IN TH POSN' ONLY SPIGOTS SEE ABOVE DAMPER FRESH AIR BOX ELEC BOX ASSY AIR OFF BOILER WATER IN 3/" BSPM BOILER WATER OUT 3/" BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESTANCE HEATER OPTIONS ELEC BOX ASSY AIR OFF NEGATIVE PRESSURE BOX SPIGOT DIAMETER 57mm FRESH AIR BOX SPIGOTS DIAMETER 5mm Page 3 SD37350 SUE

35 RESTANCE HEATER OPTIONS 600/900 VERTICAL BOTTOM OUTLET VERSIONS BOTTOM OUTLET VERSION WITH FRESH AIR AND/OR STANDARD MACHINE CONFIGURATION AIR IN ALTERNATIVE AIR OFF POSN'S SPIGOTS SEE BELOW DAMPER FRESH AIR BOX AIR OFF AIR FILTER ACCESS PANEL POOL WATER OUT " BSPM DRAIN 3/" BSPM POOL WATER IN " BSPM MAINS IN THRO' DIA 5mm off BOILER WATER OUT 3/" BSPM BOILER WATER IN 3/" BSPM ELEC BOX ASSY AIR OFF SEALING DUCT BOILER WATER IN 3/" BSPM BOILER WATER OUT 3/" BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL RESTANCE HEATER (IF FITTED) IN TH POSN' ONLY. MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESTANCE HEATER OPTIONS NEGATIVE PRESSURE BOX SPIGOT DIAMETER 57mm FRESH AIR BOX SPIGOTS DIAMETER 5mm AIR OFF 0.00 ELEC BOX ASSY FIX CONSOLE TO CONSOLE MOUNTING OR MOUNT REMOTELY (SEE SECTION ) Page 33 SD37360 SUE

36 600/900 HORIZONTAL VERSIONS STANDARD MACHINE CONFIGURATION = ELEC BOX ASSY AIR OFF BOILER WATER IN 3/" BSPM BOILER WATER OUT 3/" BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR OFF AIR IN ALTERNATIVE AIR OFF POSN'S ALTERNATIVE AIR OFF POSN' FIX CONSOLE TO CONSOLE MOUNTING OR MOUNT REMOTELY (SEE SECTION ) FRESH AIR BOX BOILER WATER IN 3/" BSPM BOILER WATER OUT 3/" BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL RESTANCE HEATER (IF REQD) IN TH POSN' ONLY FIX CONSOLE TO CONSOLE MOUNTING OR MOUNT REMOTELY (SEE SECTION ) = MAINS IN 3.00 ELEC BOX ASSY SPIGOTS SEE BELOW AIR OFF MACHINE WITH FRESH AIR/NEGATIVE PRESSURE BOX AND/OR RESTANCE HEATER OPTIONS SPIGOT SPIGOT DAMPER FRESH AIR BOX SPIGOT DETAIL (VIEW FROM AIR ON) ( SPIGOTS) DIAMETER 5mm 03 NEGATIVE PRESSURE BOX SPIGOT DIAMETER 57mm Page 3 SD37350 SUE

37 BOTTOM OUTLET VERSIONS SHOWING DUCT TO FLOOR DETAIL 600/900 VERTICAL VERSIONS 600/900 HORIZONTAL VERSIONS CABINET CABINET CABINET FOOT CABINET FOOT CABINET FOOT CABINET FOOT CABINET FOOT CABINET FOOT FLOOR DUCT SPIGOT SUPPLIED FLOOR DUCT SPIGOT SUPPLIED CABINET CABINET CABINET FOOT CABINET FOOT CABINET FOOT CABINET FOOT FLOOR DUCT SPIGOT SUPPLIED FLOOR DUCT SPIGOT SUPPLIED /500 VERTICAL VERSIONS /500 HORIZONTAL VERSIONS Page 35 SD37360 SUE

38 00/500 VERTICAL TOP OUTLET VERSIONS ELEC BOX ASSY BOILER WATER IN " BSPM BOILER WATER OUT " BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR IN AIR FILTER ACCESS PANEL AIR OFF ALTERNATIVE AIR OFF POSN'S RESTANCE HEATER (IF FITTED) IN TH POSN' ONLY. SEE ABOVE SPIGOT DAMPER SERVICE PANEL FRESH AIR BOX STANDARD MACHINE CONFIGURATION ELEC BOX ASSY MAINS IN THRO' DIA 5mm off BOILER WATER IN " BSPM BOILER WATER OUT " BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESTANCE HEATER OPTIONS AIR OFF FIX CONSOLE TO CONSOLE MOUNTING OR MOUNT REMOTELY (SEE SECTION ) NEGATIVE PRESSURE BOX SPIGOT DIAMETER 57mm FRESH AIR BOX SPIGOTS DIAMETER 5mm Page 36 SD37350 SUE

39 00/500 VERTICAL BOTTOM OUTLET VERSIONS AIR IN ALTERNATIVE AIR OFF POSN'S AIR OFF SPIGOT SEE BELOW DAMPER FRESH AIR BOX RESTANCE HEATER OPTIONS ELEC BOX ASSY BOILER WATER IN " BSPM BOILER WATER OUT " BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL STANDARD MACHINE CONFIGURATION RESTANCE HEATER (IF FITTED) IN TH POSN' ONLY. NEGATIVE PRESSURE BOX SPIGOT DIAMETER 57mm SERVICE PANEL MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR 0.00 FIX CONSOLE TO CONSOLE MOUNTING OR MOUNT REMOTELY (SEE SECTION ) FRESH AIR BOX SPIGOTS DIAMETER 5mm ELEC BOX ASSY BOILER WATER IN " BSPM BOILER WATER OUT " BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR OFF SEALING DUCT MAINS IN THRO' DIA 5mm off AIR OFF Page 37 SD37360 SUE

40 00/500 HORIZONTAL VERSIONS FIX CONSOLE TO CONSOLE MOUNTING OR MOUNT REMOTELY (SEE SECTION ) STANDARD MACHINE CONFIGURATION = ELEC BOX ASSY SERVICE PANEL AIR OFF BOILER WATER IN " BSPM BOILER WATER OUT " BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR IN AIR FILTER ACCESS PANEL AIR OFF ALTERNATIVE AIR OFF POSN'S ALTERNATIVE AIR OFF POSN' SPIGOT SPIGOT DAMPER MAINS IN DAMPER SERVICE PANEL FRESH AIR BOX RESTANCE HEATER (IF REQD) IN TH POSN' ONLY. BOILER WATER IN " BSPM BOILER WATER OUT " BSPM POOL WATER IN " BSPM DRAIN 3/" BSPM POOL WATER OUT " BSPM AIR FILTER ACCESS PANEL AIR OFF = 9.00 ELEC BOX ASSY SERVICE PANEL SPIGOT MACHINE WITH FRESH AIR OR NEGATIVE PRESSURE BOX AND/OR RESTANCE HEATER OPTIONS FRESH AIR BOX SPIGOT DETAIL (VIEW FROM AIR ON) ( SPIGOTS) DIAMETER 5mm 03 NEGATIVE PRESSURE BOX SPIGOT DIAMETER 57mm Page 38 SD37350 SUE

41 6.0 WARRANTY CONDITIONS The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be accepted if :-.The heat pump is incorrectly sized for the application..the heat pump is installed in any way that is not in accordance with the current procedures as defined by Calorex Heat Pumps Ltd. 3.The heat pump has been worked upon or is adjusted by anyone other than a person authorised to do so by Calorex Heat Pumps Ltd..The air flow to and from the machine is outside the specified limits. 5.The water flow through the machine is outside the specified limits. 6.The water ph level and/or chemical balance is outside the following limits:- Acidity ph ph Total Alkalinity, as CaCO 3 ppm 80-0 Total Hardness, as CaCO 3 ppm Total Dissolved Solids ppm 000 Maximum Salt Content ppm 8000 Free Chlorine Range ppm - Domestic Free Chlorine Range ppm 3-6 Commercial Superchlorination max 30ppm for hrs Bromine ppm - 5 Baquacil ppm 5-50 Ozone ppm 0.9 Max Maximum Copper Content ppm Aquamatic Ionic Purifier ppm Max 7.The heat pump has suffered frost damage. 8.The electrical supply is insufficient or in any way incorrect. 9.The fan amps and duct pressure are outside the specified limits. 0. The heat pump must be maintained to the service requirements in section.7. For details of extended warranty and maintenance packages please call the service number below. IF IN ANY DOUBT PLEASE ASK Note:- The Reply Paid Warranty Registration Card must be returned, to ensure that the correct warranty is given. If you do not find a Registration Card with your Heat Pump please contact the Calorex Service Department giving your name, address, model & serial number of your heat pump. A card will be sent to you for completion. service@calorex.com Web Site Please give MODEL NUMBER and SERIAL NUMBER of your heat pump when making technical or service enquiries. This will assist in correct diagnosis and ensure service can be provided with the minimum delay. Page 39 SD37360 SUE

42 X Y X 7.0 LOGIC CONTROL CIRCUITS TES ) SIGNAL TO START BOILER PUMP VIA TERMINAL BLOCKS 6 & 7 (VOLTAGE FREE SWITCH). SIGNAL TO START POOL FILTER PUMP VIA TERMINAL 8 & 9 (VOLTAGE FREE SWITCH). MACHINE WILL BRING ON POOL FILTER PUMP (IF IT T ALREADY RUNNING) WHENEVER THE COMPRESSOR RUNS OR WATER HEATING REQUIRED (SEE TE 0). ) SET POINT OF THERMOSTATS REFERRED TO AS THE SWITCHING POINT FOR SIMPLICITY WHEN IN FACT THE RELAY OPERATES AT SET POINT PLUS OR MINUS THE HYSTERES. (SEE GRAPHS BELOW). 3) WHEN MACHINE ON DEFROST THE FAN STOPS (UNLESS FAN ON DUE TO RESTIVE HEATERS BEING WARM) BUT ALL OTHER FUNCTIONS OPERATE AS RMAL. ) IF FRESH AIR SWITCH SET TO 'MIN THE DAMPERS (AIR BOX) ARE FORCED TO CLOSE AND WILL T BE UNDER MACHINE AUTO' CONTROL. 5) AIR STAT NEON (OUT) WILL SHOW DEMAND ON UCCUPIED SETTING BUT THING WILL HAPPEN BECAUSE CONTROL BY OUT STAGE OF AIR STAT (UCCUPIED). 6) TIME CLOCK MUST BE OVERRIDDEN AND UCCUPIED (PIPS IN) SELECTED IN ORDER THAT THE REMOTE V SWITCHING FEATURE CAN OPERATE. MACHINE TERMINALS & ARE VAC OPEN CIRCUIT = UCCUPIED CLOSED CIRCUIT = OCCUPIED 7) AUTO PANEL NEON ONLY WORKS WITH AIR BOX FITTED. 8) DEHUMIDIFICATION/AIR HEATING DOES T HAPPEN WHEN IN ECOMY MODE. 9) IF REMOTE ON/OFF LINK (TERMINAL & 3) REMOVED MACHINE WILL T START. 0) IN ECOMY MODE WHEN WATER HEATING REQUIRED THE POOL PUMP RUNS AND LPHW VALVE OPENS ONCE THE 60 min TIME DELAY HAS TIMED OUT). IN UCCUPIED MODE (AND T ECOMY). POOL PUMP AND LPHW WILL ONLY OPERATE ONCE THE TIME CLOCK HAS PIPPED (OCCUPIED) OR DEHUMIDIFICATION STARTS, THEN KEEPS RUNNING UNTIL THE WATER TEMPERATURE SATFIED. ) RESTANCE HEATER CAN SOMETIMES REPLACE AIR LPHW. (BOILER PUMP WILL T START WITH AIR RESTANCE HEATING). ) RCU ENERGED ON AS3 IN OCCUPIED MODE ONLY. RCU FAN WILL START WITH COMPRESSOR, AND CHANGE RCU SOLEID VALVE FROM A TO B (A CLOSES - B OPENS) UNLESS MACHINE IN DEFROST MODE WHICH WILL THEN KEEP VALVE A ENERGED. 3) TEST SHEETS (CERTIFICATE OF PERFORMANCE) PART NoS A050 to 57. ) WHEN FAN SET TO CYCLE MODE, FAN ONLY RUNS WHEN MACHINE HAS DEHUMIDIFICATION OR AIR HEATING DEMANDS. CYCLE MODE TERMINALS 33 & 3 LINKED (MADE), LINK TERMS 3 & 3 IN CONTINUOUS MODE. TECLOGIC STAT (TLK38) DEHUMIDTAT EXAMPLE ACTUAL RELATIVE HUMIDITY DEHUM COMP ON 63% DAMPERS OPEN TO MAX 65% OUT RH 6% DAMPERS CLOSED TO MIN AL RH = DEHUM STAT STAGE (COMP ON) RH = DEHUM STAT STAGE (DAMPERS OPEN) HSEt OUT RH SET POINT 60%RH 60% COMP OFF ADJUSTABLE SET POINT SET POINT = 60%RH HSEt = +3% X = HAL TECLOGIC STAT (TLK3) AIR THERMOSTAT EXAMPLE ACTUAL AIR TEMPERATURE SET POINT 8ºC RCU ON/DAMPERS OPEN TO MAX 30.5 OUT3 AS RCU OFF/DAMPERS CLOSED TO MIN 8.0 LPHW OFF AL=.5 AS = AIR STAT STAGE (LPHW HEAT AIR) UCCUPIED MODE AS = AIR STAT STAGE (LPHW HEAT AIR) OCCUPIED MODE AS3 = AIR STAT STAGE 3 (A/C COOL AIR. DAMPERS OPEN) AIR HEATING OFF.0 OCCUPIED MODE 7.5 LPHW ON HSEt=0.5 OUT AS AL=-.5 ADJUSTABLE SET POINT 3.5 OUT XUCCUPIED MODE AS AIR HEATING ON LPHW SET POINT = 8ºC X = HAL Y = HAL WATER HEAT OFF (DEHUM) 6.3 TECLOGIC STAT (TLK38) WATER THERMOSTAT EXAMPLE ACTUAL WATER TEMPERATURE SET POINT 6ºC 6. WATER HEAT ON (DEHUM) OUT WS LPHW OFF 6.0 AL WS = WATER STAT STAGE (MAX TEMP). HSEt OUT WS = WATER STAT ADJUSTABLE SET POINT 5.8 LPHW ON WS STAGE (LPHW HEAT WATER). SET POINT = 6ºC HSEt = -0. X = HAL + DPLAY INCREMENT = 0.5ºC (IE 0.+0.) Page 0 SD37360 SUE

43 MAINS LIGHT ON LOCATED NEXT TO WATER CONNECTIONS OCCUPIED MODE:- UCCUPIED MODE:- DRG No. D8050 S 7 SEE TE 6 =TIME CLOCK PIPS OUT, OR TIME CLOCK MANUAL ' I ' OR v TERMINALS 0& CLOSED. SEE TE 6 =TIME CLOCK PIPS IN, OR TIME CLOCK MANUAL '0' OR v TERMINALS 0& OPEN. MACHINE IN OCCUPIED MODE MACHINE IN UCCUPIED MODE CONTROL PANEL SWITCH SET TO 'I' (O=OFF) CONTROL PANEL SWITCH SET TO 'I' (O=OFF) SEE TE 9 (I=ON) SEE TE 9 (I=ON) CONTROL PANEL NEON ON CONTROL PANEL NEON ON LINK TO CONTINUOUS START FAN (ON TERM' BLOCK 3-3) SEE TE SEE TE FRESH AIR FRESH AIR FRESH AIR SWITCH SET TO SWITCH SET TO SWITCH SET TO 'AUTO' 'MIN' 'MAX' SEE TE 7 FRESH AIR BOX IF FITTED DAMPERS CLOSE DAMPERS OPEN TO PANEL AUTO NEON ON TO MINIMUM MAXIMUM FRESH AIR GREEN FAN STARTS AUTO NEON OFF AUTO NEON OFF ECOMY SWITCH ON MACHINE OFF TIME CLOCK & MAINS LIGHT ON COMP', FAN & DPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. LINK TO CONTINUOUS (ON START FAN SEE TE TERM' BLOCK 3-3) SEE TE FRESH AIR FRESH AIR FRESH AIR SWITCH SET TO SWITCH SET TO SWITCH SET TO 'AUTO' 'MIN' 'MAX' SEE TE 7 FRESH AIR BOX IF FITTED DAMPERS CLOSE DAMPERS OPEN TO TO MINIMUM MAXIMUM FRESH AIR FAN STARTS PANEL AUTO NEON ON AUTO NEON OFF AUTO NEON OFF GREEN ECOMY SWITCH ON MACHINE OFF TIME CLOCK & MAINS LIGHT ON COMP', FAN & DPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. SEE TE FRESH AIR SWITCH SET TO MIN. AIR TEMP BELOW AS SET POINT AIR STAT NEON (OUT&) ON PANEL AIR NEON ON SEE TE BOILER PUMP ON DUE TO WS WATER DEMAND SEND SIGNAL TO START BOILER PUMP OPEN LPHW (TO AIR) VALVE TO HEAT AIR SEE TE RH% ABOVE RH SET POINT START COMPRESSOR R/H STAT NEON (OUT) ON PANEL R/H NEON ON SEND SIGNAL TO START POOL PUMP RH% ABOVE RH SET POINT AIR STAT NEON (OUT) OFF PANEL AIR NEON OFF SEE TE BOILER PUMP ON DUE TO WS WATER DEMAND SHUT LPHW (TO AIR) VALVE STOP AIR HEATING SEE TE (IF T RUNNING) R/H STAT NEON (OUT) ON (IF FITTED) DAMPERS TO MAXIMUM FRESH AIR FAN STARTS A SEND SIGNAL TO STOP BOILER PUMP AIR TEMP ABOVE AS3 SET POINT RH STAT NEONS OFF OUT/AND OUT SEE TE AIR STAT NEON (OUT3) OFF R/H STAT NEON (OUT) OFF DAMPERS TO MINIMUM FRESH AIR BOX & FRESH AIR FAN T RUNNING SEE TE STOP COMPRESSOR PANEL D/H NEON OFF AIR STAT NEON (OUT3) ON SEND SIGNAL TO STOP POOL PUMP UNLESS WATER HEATING REQD PANEL AIR NEON OFF FRESH AIR SWITCH SET TO 'AUTO' IF FITTED OPEN DAMPERS TO MAXIMUM FRESH AIR BOX AND FRESH AIR FAN START RCU FITTED SEE TE SEE TE SEE TE 8 SEE TE IF FITTED SEE TE 0 DAMPERS TO MIN UNLESS SWITCH SET TO MAX AND FRESH AIR FAN RUNNING WATER TEMP BELOW WS SET POINT PANEL WATER NEON ON SEND SIGNAL TO START POOL PUMP BOILER PUMP ON DUE TO AS AIR DEMAND A AIR/WATER PRIORITY SWITCH MADE TO AIR WATER STAT NEONS (OUT&OUT) ON SEND SIGNAL TO START BOILER PUMP AIR & HUMIDITY STATS OFF FAN OFF WATER TEMP ABOVE WS & WS WATER STAT NEON (OUT&OUT) OFF REV VALVE OPEN (ENERGED) TO HEAT AIR SEE TE 8 REV VALVE OPEN (ENERGED) TO HEAT AIR (DEHUM) WATER STAT NEON (OUT) OFF PANEL WATER NEON OFF SEND SIGNAL TO STOP POOL PUMP UNLESS DEHUMIDIFICATION REQD SEE TE 8 BOILER PUMP ON DUE TO AS AIR DEMAND SEE TE SHUT LPHW WATER HEATING VALVE SEND SIGNAL TO STOP BOILER PUMP SEE TE SEE TE SEE TE 8 AIR TEMP BELOW AS SET POINT AIR STAT NEON (OUT) ON AIR TEMP BELOW AS SET POINT PANEL AIR NEON ON AIR STAT NEON (OUT) ON BOILER PUMP ON DUE TO WS WATER DEMAND SEND SIGNAL TO START BOILER PUMP OPEN LPHW (TO AIR) VALVE TO HEAT AIR SEE TE SEE TE RH% ABOVE RH SET POINT START COMPRESSOR PANEL R/H NEON ON SEND SIGNAL TO START POOL PUMP R/H STAT NEON (OUT) ON RH% ABOVE RH SET POINT R/H STAT NEON (OUT) ON DAMPERS WILL T OPEN DUE TO UCCUPIED MODE (FRESH AIR BOX) A (IF FITTED) SEE TE 5 AIR STAT NEON (OUT) OFF AIR STAT NEON (OUT) OFF PANEL AIR NEON OFF BOILER PUMP ON DUE TO WS WATER DEMAND SEE TE SEE TE 0 SEND SIGNAL TO STOP BOILER PUMP SHUT LPHW (TO AIR) VALVE STOP AIR HEATING SEE SEE TE TE AIR TEMP ABOVE AS3 SET POINT AIR STAT NEON (OUT3) ON AIR STAT NEON (OUT3) OFF RH STAT NEONS OUT & OUT OFF DAMPERS CLOSED TO MINIMUM (FRESH AIR BOX) STOP COMPRESSOR R/H STAT NEON (OUT) OFF PANEL D/H NEON OFF (IF FITTED) SEND SIGNAL TO STOP POOL PUMP UNLESS WATER HEATING OCCURRING ACTION DUE TO UCCUPIED MODE SEE TE SEE TE 0 WATER TEMP BELOW WS SET POINT WATER STAT NEONS (OUT&OUT) ON PANEL WATER NEON ON SEE TE 8 SEND SIGNAL TO START POOL PUMP OPEN LPHW (TO WATER) VALVE TO HEAT POOL WATER SEE TE 8 AIR/WATER PRIORITY SWITCH MADE TO AIR SEE TE DEHUM REQD BOILER PUMP ON DUE TO AS AIR DEMAND SEND SIGNAL TO START BOILER PUMP AIR & HUMIDITY STATS OFF FAN OFF A HAS TIME CLOCK NIGHT PIP BEEN MADE SEE TE 0 WATER TEMP ABOVE WS & WS WATER STAT NEONS OUT & OUT OFF SEE TE 8 REV VALVE OPEN (ENERGED) TO HEAT AIR (DEHUM) REV VALVE OPEN (ENERGED) TO HEAT AIR WATER STAT NEON (OUT) OFF PANEL WATER NEON OFF SHUT LPHW (TO WATER) VALVE, STOP WATER HEATING SEE TE 8 SEE TE SEND SIGNAL TO STOP POOL PUMP UNLESS DEHUMIDIFICATION REQD BOILER PUMP ON DUE TO AS AIR DEMAND SEE TE 8 SEND SIGNAL TO STOP BOILER PUMP OPEN LPHW (TO WATER) VALVE TO HEAT POOL WATER CHECK DEFROST MODE SEE TES 3 & Page SD37360 SUE

44 TES ) SIGNAL TO START BOILER PUMP VIA TERMINAL BLOCKS 6 & 7 (VOLTAGE FREE SWITCH). ) "SET POINT" OF THERMOSTATS REFERRED TO AS THE SWITCHING POINT FOR SIMPLICITY WHEN IN FACT THE RELAY OPERATES AT SET POINT, PLUS OR MINUS THE HYSTERES. (SEE GRAPHS BELOW). 3) WHEN MACHINE ON DEFROST THE FAN STOPS BUT ALL OTHER FUNCTIONS OPERATE AS RMAL. ) IF FRESH AIR SWITCH SET TO 'MIN' THE DAMPERS (AIR BOX) ARE FORCED TO CLOSE AND WILL T BE UNDER MACHINE 'AUTO' CONTROL. 5) AIR STAT NEON (OUT) WILL SHOW DEMAND ON UCCUPIED SETTING BUT THING WILL HAPPEN BECAUSE CONTROL BY OUT STAGE OF AIR STAT (UCCUPIED) 6) TIME CLOCK MUST BE OVERRIDDEN AND UCCUPIED (PIPS IN) SELECTED IN ORDER THAT THE REMOTE v SWITCHING FEATURE CAN OPERATE. MACHINE TERMINALS 0 & ARE vac, OPEN CIRCUIT = UCCUPIED, CLOSED CIRCUIT = OCCUPIED. 7) PANEL AUTO NEON (GREEN) ONLY WORKS WHEN AIR BOX FITTED. 8) IF REMOTE ON/OFF LINK (TERMINAL & 3) REMOVED MACHINE WILL T START. 9) RESTANCE HEATER CAN SOMETIMES REPLACE AIR LPHW. (BOILER PUMP WILL T START WITH AIR RESTANCE HEATING). 0) R.C.U. ENERGED ON AS3 IN OCCUPIED MODE ONLY. (R.C.U. FAN WILL START) WITH COMPRESSOR, AND CHANGE R.C.U. SOLEID VALVES FROM A TO B (A CLOSES - B OPENS) UNLESS M/C IN DEFROST MODE WHICH WILL THEN KEEP VALVE A ENERGED. ) WHEN FAN SET TO CYCLE MODE, FAN ONLY RUNS WHEN MACHINE HAS DEHUMIDIFICATION OR AIR HEATING DEMANDS. CYCLE MODE TERMINALS 33 & 3 LINKED (MADE). FIT LINK BETWEEN TERMS 3 & 3 TO RUN MACHINE IN CONTINUOUS MODE. OCCUPIED MODE:- UCCUPIED MODE:- =TIME CLOCK PIPS OUT, OR TIME CLOCK MANUAL 'I' OR V TERMINALS 0& CLOSED. =TIME CLOCK PIPS IN, OR TIME CLOCK MANUAL '0' OR V TERMINALS 0& OPEN. RH = DEHUM STAT STAGE (DAMPERS OPEN) AS = AIR STAT STAGE (LPHW HEAT AIR) UCCUPIED MODE AS = AIR STAT STAGE (LPHW HEAT AIR) OCCUPIED MODE AS3 = AIR STAT STAGE 3 (A/C COOL AIR. DAMPERS OPEN) DEHUMIDTAT EXAMPLE TECLOGIC STAT (TLK38) AIR THERMOSTAT EXAMPLE TECLOGIC STAT (TLK3) ACTUAL RELATIVE HUMIDITY SET POINT 60%RH DEHUM COMP ON 63% HSEt 60% COMP OFF OUT RH DAMPERS OPEN TO MAX 65% X OUT RH 6% DAMPERS CLOSED TO MIN ADJUSTABLE SET POINT AL ACTUAL AIR TEMPERATURE SET POINT 8ºC AIR HEATING OFF.0 AS 3.5 AIR HEATING ON LPHW X 8.0 LPHW OFF OCCUPIED MODE OUT RCU ON/DAMPERS OPEN TO MAX STOP COMP IF DAMPERS/RCU 30.5 Y HSEt= LPHW ON UCCUPIED MODE OUT3 AS RCU OFF/DAMPERS CLOSED TO MIN OUT AS AL=-.5 AL=.5 ADJUSTABLE SET POINT SET POINT = 60%RH HSEt = +3% X = HAL SET POINT = 8ºC X = HAL Y = HAL Page SD37360 SUE

45 MAINS LIGHT ON LOCATED NEXT TO WATER CONNECTIONS SEE TE 6 MACHINE IN OCCUPIED MODE (O=OFF) CONTROL PANEL SWITCH SET TO 'I' (I=ON) CONTROL PANEL NEON ON SEE TE 8 SEE TE 6 MACHINE IN UCCUPIED MODE CONTROL PANEL (O=OFF) SWITCH SET TO 'I' (I=ON) CONTROL PANEL NEON ON SEE TE START FAN LINK TO CONTINUOUS (ON TERM' BLOCK LINK TO CONTINUOUS (ON TERM' BLOCK 3-3) SEE TE START FAN 3-3) SEE TE SEE TE FRESH AIR FRESH AIR FRESH AIR SWITCH SET SWITCH SET SWITCH SET TO 'AUTO' TO 'MAX' TO 'MIN' SEE TE 7 FRESH AIR BOX IF FITTED DAMPERS CLOSE DAMPERS OPEN TO TO MINIMUM MAXIMUM FRESH AIR FAN STARTS PANEL AUTO NEON ON GREEN AUTO NEON OFF AUTO NEON OFF MACHINE OFF. TIME CLOCK & MAINS LIGHT ON. COMP', FAN & DPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. FRESH AIR FRESH AIR FRESH AIR SWITCH SET SWITCH SET SWITCH SET TO 'AUTO' TO 'MIN' TO 'MAX' FRESH AIR BOX IF FITTED DAMPERS CLOSE DAMPERS OPEN TO TO MINIMUM MAXIMUM FRESH AIR FAN STARTS PANEL AUTO NEON ON GREEN AUTO NEON OFF AUTO NEON OFF MACHINE OFF. TIME CLOCK & MAINS LIGHT ON. COMP', FAN & DPLAYS OFF. VALVE SHUT. DAMPERS STAY IN POSITION LAST CALLED FOR. SEE TE AIR TEMP BELOW AS SET POINT AIR STAT NEON (OUT&) ON AIR STAT NEON (OUT) OFF PANEL AIR NEON ON PANEL AIR NEON OFF SEE TE 5 AIR TEMP BELOW AS SET POINT AIR STAT NEON (OUT) OFF SEE TE SEE TE SEND SIGNAL TO START BOILER PUMP SEE TE 9 SEND SIGNAL TO STOP BOILER PUMP SEE TE 9 AIR TEMP BELOW AS SET POINT SEE TE 9 SEE TE 9 OPEN LPHW (TO AIR) SHUT LPHW (TO AIR) VALVE VALVE TO HEAT AIR TO STOP AIR HEATING PANEL AIR NEON ON PANEL AIR NEON OFF SEE TE AIR TEMPABOVE AS3 SET POINT AIR STAT NEON (OUT3) ON AIR STAT NEON (OUT) ON SEE TE SEE TE 9 SEND SIGNAL TO START BOILER PUMP AIR STAT NEON (OUT) OFF SEE TE SEND SIGNAL TO SEE TE 9 STOP BOILER PUMP AIR STAT NEON (OUT3) OFF FRESH AIR SWITCH SET TO 'AUTO' FRESH AIR BOX FITTED SEE TE 9 OPEN LPHW (TO AIR) VALVE TO HEAT AIR SEE TE 9 SHUT LPHW (TO AIR) VALVE STOP AIR HEATING RH% ABOVE RH SET POINT RH STAT NEONS OUT AND OUT OFF IF FITTED IF FITTED DAMPERS TO OPEN DAMPERS MIN UNLESS TO MAXIMUM SWITCH AND FRESH AIR BOX FRESH AIR FAN AND FRESH AIR RUNNING FAN STARTS RCU FITTED SEE TE 0 RCU FITTED STOP COMPRESSOR SEE TE RH% ABOVE RH SET POINT SEE TE AIR TEMP ABOVE AS3 SET POINT AIR STAT NEON (OUT3) OFF ACTION DUE TO UCCUPIED MODE RH STAT NEONS OUT & OFF AIR STAT NEON (OUT3) ON FRESH AIR BOX OR RCU FITTED START COMPRESSOR STOP COMPRESSOR R/H STAT NEON (OUT) ON START COMPRESSOR STOP COMPRESSOR PANEL R/H NEON ON PANEL D/H NEON OFF R/H STAT NEON (OUT) ON PANEL R/H NEON ON PANEL D/H NEON OFF FRESH AIR SWITCH SET TO MIN. RH% ABOVE RH SET POINT R/H STAT NEON (OUT) ON IF FITTED IF FITTED DAMPERS TO DAMPERS MAXIMUM FRESH CLOSED TO AIR BOX AND MINIMUM FRESH FRESH AIR FAN AIR BOX AND START FRESH AIR FAN T RUNNING RH% ABOVE RH SET POINT R/H STAT NEON (OUT) ON (IF FITTED) (IF FITTED) DAMPERS WILL DAMPERS T OPEN DUE CLOSED TO TO MINIMUM MINIMUM (FRESH UCCUPIED AIR BOX) MODE (FRESH AIR BOX) CHECK DEFROST MODE SEE TES 3 & 0 Page 3 SD37360 SUE

46 TES ) "SET POINT" OF DIGITAL CONTROLLERS REFERRED TO AS THE SWITCHING POINT FOR SIMPLICITY WHEN IN FACT THE RELAY OPERATES AT SET POINT PLUS OR MINUS THE HYSTERES. (SEE GRAPHS BELOW). ) WHEN MACHINE ON DEFROST, FAN STOPS BUT ALL OTHER FUNCTIONS OPERATE AS RMAL. 3) IF FRESH AIR SWITCH SET TO 'MIN' THE DAMPERS (AIR BOX) ARE FORCED TO CLOSE AND WILL T BE UNDER MACHINE 'AUTO' CONTROL. ) PANEL AUTO NEON (GREEN) ONLY WORKS WHEN AIR BOX FITTED. 5) IF REMOTE ON/OFF LINK (TERMINAL & 3) REMOVED MACHINE WILL T START. 6) RCU ENERGED ON AS, RCU FAN WILL START WITH COMPRESSOR, AND CHANGE RCU SOLEID VALVES FROM A TO B (A CLOSES - B OPENS) UNLESS M/C IN DEFROST MODE WHICH WILL THEN KEEP VALVE A ENERGED. 7) WHEN FAN SET TO CYCLE MODE, FAN ONLY RUNS WHEN MACHINE HAS DEHUMIDIFICATION OR AIR HEATING DEMANDS. CYCLE MODE TERMINALS 33 & 3 (LINKED (MADE) LINK TO TERMS 3 & 3 IN CONTINUOUS MODE.8) IF REMOTE ON/OFF LINK (TERMINAL & 3) REMOVED MACHINE WILL T START. RH = DEHUM STAT STAGE (COMP ON) RH = DEHUM STAT STAGE (DAMPERS OPEN) AS = AIR STAT STAGE (HEAT AIR). AS = AIR STAT STAGE (A/C COOL AIR. DAMPERS OPEN). TECLOGIC STATS (TLK38) ACTUAL RELATIVE HUMIDITY SET POINT 60%RH DEHUMIDTAT EXAMPLE DEHUM COMP ON 63% HSEt 60% COMP OFF =3 OUT RH DAMPERS OPEN TO MAX 65% HAL =3 OUT RH 6% DAMPERS CLOSED TO MIN ADJUSTABLE SET POINT AL AIR THERMOSTAT EXAMPLE ACTUAL AIR TEMPERATURE SET POINT 8ºC LPHW OFF LPHW ON HSEt =0.5 OUT AS RCU ON/DAMPERS OPEN TO MAX STOP COMP IF DAMPERS OR RCU 30.5 HAL =0.5 OUT AS 30.0 RCU OFF/DAMPERS CLOSED TO MIN ADJUSTABLE SET POINT AL SET POINT = 60%RH SET POINT = 8ºC Page SD37360 SUE

47 MAINS LIGHT ON LOCATED NEXT TO WATER CONNECTIONS CONTROL PANEL SWITCH SET TO 'I' (O=OFF) (I=ON) CONTROL PANEL NEON ON SEE TE 5 START FAN LINK TO CONTINUOUS (ON TERM' BLOCK 3-3) SEE TE 7 SEE TE 3 FRESH AIR FRESH AIR SWITCH SET TO SWITCH SET TO 'AUTO' 'MIN' SEE TE FRESH AIR BOX IF FITTED FRESH AIR SWITCH SET TO 'MAX' MACHINE OFF. MAINS LIGHT ON. COMP', FAN & DPLAYS OFF. DAMPERS STAY IN POSITION LAST CALLED FOR. PANEL AUTO NEON ON GREEN DAMPERS CLOSE TO MINIMUM AUTO NEON OFF DAMPERS OPEN TO MAXIMUM FRESH AIR FAN STARTS AUTO NEON OFF SEE TE AIR TEMP BELOW AS SET POINT AIR STAT NEON (OUT) ON PANEL AIR NEON ON AIR STAT NEON (OUT) OFF PANEL AIR NEON OFF SEE TE AIR TEMP ABOVE AS SET POINT AIR STAT NEON (OUT) ON PANEL AIR NEON OFF FRESH AIR BOX FITTED AIR STAT NEON (OUT) OFF FRESH AIR SWITCH SET TO 'AUTO' OPEN TO DAMPERS MAXIMUM FRESH AIR BOX DAMPERS CLOSED TO MINIMUM FRESH AIR BOX RCU FITTED SEE TE 6 RCU FITTED RH% ABOVE RH SET POINT STOP COMP' PANEL R/H NEON ON PANEL D/H NEON OFF R/H STAT NEON (OUT) ON START COMPRESSOR STOP COMPRESSOR RH% ABOVE RH SET POINT R/H STAT NEON (OUT) ON FRESH AIR BOX IF FITTED FRESH AIR SWITCH SET TO MINIMUM OPEN TO DAMPERS MAXIMUM FRESH AIR BOX FRESH AIR FAN STARTS DAMPERS CLOSED TO MINIMUM FRESH AIR BOX CHECK DEFROST MODE SEE TES & 6 Page 5 SD37360 SUE

48 7. RELAY FUNCTIONS R Energised on power on switch being made on AA and AA+LPHW /resistance heating. Energised on power on switch being made and economy switch in the full operation mode on the AW. When not energised and the machine is switched on allows the pool pump & water LPHW to operate in economy mode once 60 min timer on AW machine (if fitted) has timed out, when water temperature is below stage. R Energised when stage (unoccupied) or stage in occupied mode. Air heating is needed bring on the LPHW air valve or resistance heater (used on AA machine to bring on the fan if air is below stage. R has to be made in occupied mode). It will also bring on the fan on all machines if fan is not already running. R3 Energised when dehumidification is needed as long as LP and HP pressure switches are not in fault mode. R Energised when time clock is in occupied mode on AA+LPHW / resistance heating and AW machine. On AA with air box or RCU energised once the power switch is made. R5 Energised on humidity still rising above stage, which in turn will open the dampers (only if air box is fitted and R is energised). R6 Energised when damper switch on control panel is switched from auto mode (only if air box is fitted). R7 Energised to switch the air box to max (if air box is fitted). R8 Energised when water temperature is above stage it energise the reversing valve to send dehumidification heat to air (AW machine only). R9 Energised if LPHW water heating is required to start the pool pump only in the occupied mode and economy mode or if at any time dehumidification is happening (AW machine only). R0 Energised by relay 9 to bring on water LPHW valve. Only if water temperature is below stage in occupied mode only. (AW machine only). R Used on AA / AA+LPHW / resistance heating machine without options to stop dehumidification once air temperature is above stage on AA machine, above stage 3 on AA+LPHW / resistance heating. R Used only if RCU unit is fitted energised if air temperature is above stage on an AA machine with out time clock or stage 3 on all other machines. R3 Used only on AW machine to start LPHW water heating and pool pump if water temperature is below stage in the occupied mode only. R Provides volt free contacts for remote control power indication. RE Energised by R to bring on the fan when the fan is wired to cycle mode when air temperature is low. RE Energised in defrost mode to bring on defrost lamp and if RCU is fitted to change back to valve A if RCU is calling for, valve B when machine is in defrost mode. RE 3 Energised once R is made unless the soft start has a fault or soft start link is broken. Which would cause RE 3 to drop out bring on the fault lamp. RE Provides volt free contacts for fan running. Page 6 SD37360 SUE

49 7. PARAMETER SETTINGS SETTING INSTRUCTIONS (TECLOGIC STATS,TLK 38, TLK 3) TE : These parameter settings are programmed by the supplier to the figures shown below and should not need altering. See Section 3. for description of how to alter customer settings. a. To Program the Set Point (Humidity and Water). Press down P, SP and Set Point value (e.g. 60) will be displayed alternately. Press the or key to change the value of SP. Once the desired value is displayed press P to memorise the value. The display will revert to the present reading. TE : If anything else shows on the display leave alone for minute, until the display returns to normal. b. To Program the Set Point (Air) Press down P, SP and Set Point value (e.g 8) will be displayed alternately. Press P again, AL and AL value (-.5) will be displayed alternately. This is the difference between the Set Point and AL plus HSEt e.g = ºC Night set back or unoccupied temperature. SP and AL can be changed in the same way as described above for all Variheats. To Program the Parameters. Press and hold down the P key for approximately seconds. You will enter the Programme Control Group Menu. Press the key to reach ConF, then press P again. Enter the Password -8 by holding the key. If you pass -8 press the key to go back, then press P again, this will take you into the Programmable Group Menu. Press the or key to get into the relevant group and press P again. You should now be at the first parameter of that group. To read or change the setting press P, then to change the setting (if needed) press the or key. Once the correct setting is reached press P again. To move to the next setting press the or key and repeat above. *TE Some functions are not present, either because they are instrument dependant or because they are disabled. To return to Programmable Group Menu leave keys alone for 0 seconds approx. To return to Normal Mode leave alone for a further 0 seconds approx. PARAMETER FUNCTION SETTING AIR AIR NAME WATER AIR HEATING AIR HEATING HUMIDITY GROUP SPכ (RELATIVE TO SET POINT ) nsp FACTORY SETTING CAN BE SET FROM KEYPAD SP SET POINT SPLL FACTORY SETTING SPHL FACTORY SETTING GROUP InPכ (RELATIVE TO THE MEASURED OUTPUT ) SEnS FACTORY SETTING Ptc Ptc Ptc 0.0 * SSC FACTORY SETTING 0 * FSC FACTORY SETTING 00 dp FACTORY SETTING 0 * Unit FACTORY SETTING º C º C º C FiL FACTORY SETTING OFF Fild FACTORY SETTING OFF OFF OFF OFF OFSt MEASURING OFFSET rot FACTORY SETTING InE FACTORY SETTING Our Our Our Our OPE FACTORY SETTING * Dif FACTORY SETTING nof GROUP Outכ (RELATIVE TO OUTPUTS) 0F FACTORY SETTING.rEG.rEG ALno.rEG 0F FACTORY SETTING Alnc ALno.rEG ALno * 03F FACTORY SETTING ALno * 0F FACTORY SETTING ALno Page 7 SD37360 SUE

50 PARAMETER FUNCTIO N SETTING AIR AIR NAME W ATER AIR HEATING AIR HEATING HUMIDITY GROUP AL כ (RELATIVE TO ALARM AL) OAL OUTPUT, ALARM AL ADDRESSED Out Out Out Out ALT FACTORY SETTING LodE HidE LodE HidE Ab FACTORY SETTING AL ALARM AL THRESHOLD ALL FACTORY SETTING ALH FACTORY SETTING HAL ALARM AL HYSTERES ALd FACTORY SETTING OFF OFF O FF O FF ALi FACTORY SETTING no no no no GROUP AL כ (RELATIVE TO ALARM AL) * 0AL OUTPUT, ALARM AL ADDRESSED Out3 * ALt FACTORY SETTING HidE * Ab FACTORY SETTING 0 * AL ALARM AL THRESHOLD.5 * ALL FACTORY SETTING * * ALH FACTORY SETTING HAL ALARM AL HYSTERES 0.5 * ALd FACTORY SETTING O FF * ALi FACTORY SETTING no GROUP AL3 כ (RELATIVE TO ALARM AL3) * 0AL3 OUTPUT, ALARM AL3 ADDRESSED Out * AL3t FACTORY SETTING HidE * Ab3 FACTORY SETTING 0 * AL3 ALARM AL3 THRESHOLD.5 * AL3L FACTORY SETTING * AL3H FACTORY SETTING * HAL3 ALARM AL3 HYSTERES 0.5 * AL3d FACTORY SETTING OFF * AL3i FACTORY SETTING no GROUP LBaכ (RELATIVE TO LOOP BREAK ALARM) 0LbA FACTORY SETTING OFF OFF OFF OFF LbAt FACTORY SETTING OFF OFF OFF OFF Page 8 SD37360 SUE

51 PARAMETER FUNCTIO N SE TTING AIR AIR NAME W ATER AIR HEATING AIR HEATING HUMIDITY GROUP regכ (RELATIVE TO CONTROL) Cont FACTORY SETTING On.FA On.FA On.FA On.FA Func FACTORY SETTING HEAt HEAt HEAt CooL HSEt FACTORY SETTING SloR FACTORY SETTING nf nf nf nf dur.t FACTORY SETTING nf nf nf nf SLoF FACTORY SETTING nf nf nf nf GROUP PAn (RELATIVE TO USER INTERFACE) USrb FACTORY SETTING nof nof nof nof disp FACTORY SETTING def def def def AdE FACTORY SETTING OFF OFF OFF OFF Edit FACTORY SETTING SAE SAE SAE SAE TE Any group or parameter not shown on list should be left as factory setting. SWITCHING POINTS SET POINT OUT OUT OUT3 ON OFF ON OFF ON OFF RELATIVE HUMIDITY = 60% AIR TEMPERATURE = 8ºC WATER TEMPERATURE = 6ºC ERROR "---" PROBE INTERRUPTED "uuuu" OR "oooo" PROBE LIMIT UNDER/OVER RANGE LbA LOOP CONTROL INTERRUPTED ErEP POSSIBLE AMALY OF EPROM MENU ACTION VERIFY CORRECT CONNECTION BETWEEN PROBE AND STAT, THEN VERIFY CORRECT FUNCTIONING OF PROBE. CHECK WORKING OF PROBE AND ACTUATOR AND SWAP INSTRUMENT TO reg CONTROL PUSH P KEY Programming the offset If the reading on the digital controller is not the same as the actual pool hall air temperature, water temperature or relative humidity, it may be necessary to program the offset. Press and hold the P key for approximately seconds. You will then enter the programme control group menu. Press the up key to reach ConF, then press P again and enter the password -8 by holding the down key. If you pass -8 use the up key to go back, then press P again. This takes you into the programmable group menu. Press the up or down key to get to group InP and then press P again. Press the up key until OFSt is displayed. This parameter can be adjusted by pressing the P key and then the up and down key until the Tecnologic stat reading and the actual reading are the same. Example: If the Pool water is 6.0ºC and the digital controller reads 5.5ºC the offset to be entered is When the correct offset has been inserted, leave the stat alone for 0 seconds and the display will return to normal. Great care should be taken to leave all other parameters at their factory settings. Page 9 SD37360 SUE

52 SETTING INSTRUCTIONS (TECLOGIC STATS,TLZ) TE : These parameter settings are programmed by the supplier ready for use. The parameter tables below should only be needed for reference. See Section 3. for description of how to alter customer settings. a. To Program the Set Point (Air and Water). Press down P, SP and Set Point value (e.g. 60) will be displayed alternately. Press the or key to change the value of SP. Once the desired value is displayed press P to memorise the value. The display will revert to the present reading. TE : If anything else shows on the display leave alone for minute, until the display returns to normal.. To program the parameters.press and hold the P key for approximately seconds, until the display shows 0, the programme control menu. Enter the password 8 by holding the key. If you pass 8 press the key to go back. Then press P again. This will take you into the programmable menu. To read or change the setting press P, then to change the setting (if needed) press the or key. Once the correct setting is reached press P again. To move to the next setting press the or key and repeat above. To return to normal mode leave alone for a further 0 seconds approx. PARAMETER NAME FUNCTION WATER AIR SPLL MINIMUM SET POINT 0 0 SPHL MAXIMUM SET POINT 0 0 SEnS PROBE TYPE Ptc Ptc OFS PROBE CALIBRATION Unit UNIT OF MEASUREMENT OC OC dp DECIMAL POINT ON ON FiL MEASUREMENT FILTER OFF OFF HSEt DIFFERENTIAL tone ACTIVE TIME OUTPUT OUT FOR PROBE BROKEN OFF OFF tofe DEACTIVATION TIME OUTPUT FOR PROBE BROKEN OFF OFF Func FUNCTION MODE OUPUT OUT HEAT HEAT PSC TYPE OF COMPRESSOR PROTECTION: = DELAY AT SWITCH ON = DELAY AFTER SWITCH ON 3 = DELAY BETWEEN STARTS PtC COMPRESSOR PROTECTION TIME OFF OFF od DELAY AT POWER ON OFF OFF HAL RELATIVE HIGH TEMPERATURE ALARM THRESHOLD LAL RELATIVE LOW TEMPERATURE ALARM THRESHOLD OFF OFF dal TEMPERATURE ALARM DIFFERENTIAL Ald TEMPERATURE ALARM DELAY OFF OFF PAL TEMPERATURE ALARM DELAY AT POWER ON OFF OFF dald Usrb FUNCTION MODE KEY U: OFF OFF OFF = FUNCTION = ON/STAND-BY PASS ACCESS PASSWORD TO PARAMETER FUNCTIONS 8/38 8 SP SET POINT 6 8 SET POINT AIR TEMPERATURE 8ºC SWITCHING POINTS OUT OUT ON OFF ON OFF WATER TEMPERATURE 6ºC Page 50 SD37360 SUE

53 SETTING INSTRUCTIONS (STORK STATS) TE: THESE PARAMETER SETTINGS ARE SET BY CALOREX AT THE FACTORY TO THE FIGURES SHOWN BELOW AND SHOULD T NEED ALTERING. SEE SECTION 3. FOR DESCRIPTION OF HOW TO ALTER CUSTOMER SETTINGS.. WITH MAINS LIGHT ON, PRESS DOWN TOGETHER AND HOLD.. WHEN 'P' DPLAYED PRESS AND HOLD UNTIL 'P3' DPLAYED. 3. PRESS AND HOLD,WHEN 'PA' APPEARS PRESS TOGETHER UNTIL 'A' APPEARS.. PRESS AND HOLD 'SET' TO SHOW SETTING AND ALTER USING OR. WHEN REQUIRED SETTING DPLAYED RELEASE 'SET' AND MOVE TO 'A' USING 5. REPEAT ABOVE PROCEDURE TO TABLE BELOW UNTIL ALL 'A' SETTINGS COMPLETED 6. PRESS AND HOLD UNTIL 'P' APPEARS, THEN PRESS 'SET' TO SHOW SETTING. 7. REPEAT 'P' SETTINGS AS 'A' SETTING PROCEDURE. 8. WHEN ALL SETTINGS COMPLETED CONTROL WILL REVERT TO RMAL DPLAY. P P P3 P P5 P6 P9 P30 P3 P3 A A A3 A A5 A6 A8 A9 A0 A A9 A0 A30 A3 A0 A A50 A5 A5 A53 A5 A55 A60 A70 DELTA 'T' IN DEGREES CENTIGRADE BETWEEN THERMOSTAT STAGE & STAGE DIFFERENTIAL OF THERMOSTAT STAGE. DIFFERENTIAL OF THERMOSTAT STAGE. CUSTOMER SETTING LIMIT (LOWER) CUSTOMER SETTING LIMIT (HIGHER) ACTUAL TEMP DPLAY ADJUSTMENT. KEYBOARD LOCK, UNLOCK 0 N/A (LOWER BOUNDARY VALUE K3) N/A (UPPER BOUNDARY VALUE K3) K3 HYSTER SWITCH MODE K 0 = HEATING = COOLING SWITCH MODE K 0 = HEATING = COOLING SENSOR ERROR FUNCTION K 0 = 0N,SWITCH OFF = ON,SWITCH ON 0 = OFF SENSOR ERROR FUNCTION K = ON K TO K SEPARATE OR DELTA T SEP = 0 T = CONTROL MODE K 0 = THERMOSTAT = K RAMP 3 = K RAMP OBSOLETE DPLAY MODE = WITH DECIMAL PLACES,,3 ETC 0 = WITHOUT DECIMAL PLACES WEIGHTING FACTOR % VOLTAGE INPUT Tu VOLTAGE INPUT To PARAMETER 0 = T LOCKED, = 'A' LOCKED SETTINGS = 'A' & 'P' LOCKED KEYPAD BLEEP = ON 0 = OFF N/A N/A 0 = HYSTER SYMETRICAL ABOUT SET POINT = OR ONE SIDE OF SET POINT HEATING = BELOW SET POINT COOLING = ABOVE SET POINT AS ABOVE FOR K MINIMUM ON TIME K MINIMUM OFF TIME K MINIMUM ON TIME K MINIMUM OFF TIME K TIME DELAY K/K AFTER POWER ON TIME DELAY AFTER K BEFORE K ALLOWED TO SWITCH ON. SENSOR TYPE. TERMINALS '0' & '' (FIXED) SOFTWARE TIME CONSTANT. TIME FOR DPLAY/CONTROL TO REACH NEW VALUE N/A N/A A80 = C 0 = F A90 A9 A9 A93 N/A N/A N/A N/A SETTING AIR STAGE ONLY N/A N/A PARAMETER FUNCTION WATER HUMIDITY N/A 0 7 Page 5 SD37360 SUE

54 8.0 SOUND GRAPH K K K 8K 6K CENTRE FREQUENCIES (Hz) D9770 iss BAND SOUND PRESSURE LEVEL (db) CURVES=E RATING NUMBERS (NR) TEST SUBJECT :- VH3 600 DATE :- 30:9:0 MEASURED dba :- AIR ON = 63.5 AIR OFF= 69 SIDE= 6.5 DTANCE FROM E SOURCE :- 3M BACKGROUND = AIR OFF SIDE AIR ON AIR ON BACKGROUND SIDE Page 5 SD37360 SUE

55 BAND SOUND PRESSURE LEVEL (db) CURVES=E RATING NUMBERS (NR) TEST SUBJECT :- VH3 900 DATE :- :0:0 MEASURED dba :- AIR 0N= 66.5 AIR OFF= 68 SIDE= 66.5 DTANCE FROM E SOURCE :- 3M BACKGROUND= K K K 8K 6K CENTRE FREQUENCIES (Hz) AIR OFF AIR OFF SIDE SIDE AIR ON AIR ON AIR ON BACKGROUND SIDE AIR ON AIR OFF SIDE D977 iss Page 53 SD37360 SUE

56 K K K 8K 6K CENTRE FREQUENCIES (Hz) BAND SOUND PRESSURE LEVEL (db) CURVES=E RATING NUMBERS (NR) TEST SUBJECT :- VH3 00 DATE :- :0:0 MEASURED dba :- AIR ON= 70.5 AIR OFF= 76.5 SIDE= 7 DTANCE FROM E SOURCE :-3M BACKGROUND = SIDE SIDE AIR OFF AIR ON BACKGROUND D977 iss Page 5 SD37360 SUE

57 K K K 8K 6K CENTRE FREQUENCIES (Hz) BAND SOUND PRESSURE LEVEL (db) CURVES=E RATING NUMBERS (NR) TEST SUBJECT :- VH3 500 DATE :- :0:0 MEASURED dba :- AIR ON= 76 AIR OFF= 80 SIDE= 7 DTANCE FROM E SOURCE :- 3M BACKGROUND = AIR OFF AIR OFF AIR ON SIDE SIDE SIDE AIR OFF AIR ON BACKGROUND D9773 iss Page 55 SD37360 SUE

58 9.0 FAN CURVES FAN CURVE VH3-600/900 STATIC PRESSURE (Pa) Page 56 SD37360 SUE

59 Page 57 SD37360 SUE

60 FAN CURVE VH3-/500 Pt.kp/m² Page 58 SD37360 SUE

Technical Manual DELTA SYSTEM. (SD Issue 73) 05/09/13

Technical Manual DELTA SYSTEM. (SD Issue 73) 05/09/13 Technical Manual DELTA SYSTEM (SD340460 Issue 73) 05/09/3 HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment,only competent persons should carry out any work on

More information

Owner Installation Manual for PROPAC 30/45/70/90/140 M/MY AIR/WATER HEAT PUMPS (SD ISSUE 28) 18/03/11 CONTENTS

Owner Installation Manual for PROPAC 30/45/70/90/140 M/MY AIR/WATER HEAT PUMPS (SD ISSUE 28) 18/03/11 CONTENTS Owner Installation Manual for PROPAC 0/4/70/90/40 M/MY AIR/WATER HEAT PUMPS (SD66 ISSUE 8) 8/0/ CONTENTS AIR/WATER HEAT PUMPS... THE HEAT PUMP CYCLE... INSTALLATION... 4. SITING... 4. AIR FLOW... 4. PLUMBING...

More information

Installation Manual Compac 6/8

Installation Manual Compac 6/8 OWNER AND INSTALLATION MANUAL FOR COMPAC 6/8 SWIMMING POOL HEAT PUMPS (SD636650 Iss.2 23/12/10) Health and Safety Warning: As the heat pump includes electrical and rotational components it is required

More information

Installation Manual PPT8/12/16/22LX/LY SLIMLINE

Installation Manual PPT8/12/16/22LX/LY SLIMLINE OWNER/INSTALLATION MANUAL FOR (SD638153 Iss.10 08/11/12) Health and Safety Warning: As the heat pump includes electrical and rotational components it is required that only trained and competent persons

More information

Owner/Installation Manual

Owner/Installation Manual Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier. Owner/Installation Manual VARIHEAT VH3 AA/AW600/900/200A/BVHXF

More information

Technical guide Pro-Pac H HY. Air/water heat pumps

Technical guide Pro-Pac H HY. Air/water heat pumps Technical guide Pro-Pac 45 70 90 1 H HY Air/water heat pumps Comprehensive support Comprehensive engineering support is provided by our experienced and well qualified team. Calorex units are designed,

More information

CALOREX TECHNICAL GUIDE PRO-PAC H HY. Air/water heat pumps

CALOREX TECHNICAL GUIDE PRO-PAC H HY. Air/water heat pumps PRO-PAC 30 45 70 90 140 H HY Air/water heat pumps Comprehensive support Comprehensive engineering support is provided by our experienced and well qualified team. Calorex units are designed, tested and

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location

More information

Plant Growth Cabinets

Plant Growth Cabinets Plant Growth Cabinets MODELS INCLUDE: TPG-2400-TH-Co2 TPG-2900-TH-Co2 Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline Scientific ABN 80 000 859 129 9 Tarlington Place, Smithfield. N.S.W. 2164.

More information

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter

More information

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning

More information

TECHNICAL MANUAL PD150/DF150/AX/AJX AND OTW15/TTW15AX

TECHNICAL MANUAL PD150/DF150/AX/AJX AND OTW15/TTW15AX Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier. TECHNICAL MANUAL DH5/ FD5/TTK50/ PD50/DF50/AX/AJX AND OTW5/TTW5AX

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

Plant Growth Cabinets

Plant Growth Cabinets Plant Growth Cabinets MODEL: TPG-1260-TH-Co2 Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline Scientific ABN 80 000 859 129 9 Tarlington Place, Smithfield. N.S.W. 2164. Australia. P.O. Box 6862,

More information

Model 1820 Dehumidifier

Model 1820 Dehumidifier Model 1820 Dehumidifier Installation Instructions SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing.

More information

Digital Precise Air Control - DPAC

Digital Precise Air Control - DPAC Digital Precise Air Control - DPAC Mode Enable Sensor Options The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during Occupied operation. The following options

More information

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate

More information

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Unvented Electric Water Heater 10/15 litre Undersink

Unvented Electric Water Heater 10/15 litre Undersink Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870 Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870 Table of Contents Troubleshooting Diagnostic Codes... 2 E1... 2 E2, E3... 3 E4.4 E5, E6... 7 E7, E8... 8 E9.9 Verifying Capacity...

More information

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017 24 1 2 23 3 4 5 20 6 I 19 7 18 8 9 15 14 11 13 12 i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book i 24 OFF MAX E STATUS BURNER RESET MIN PRE MIN MAX HEAT PREHEAT

More information

Harmo Powerpack Horizontal Units Installation & instruction manual

Harmo Powerpack Horizontal Units Installation & instruction manual Imported by: Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www.harmopool.eu Harmo Powerpack Horizontal Units Installation & instruction manual Table of content Introduction... 3 Characteristics...

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

EH0533 Indoor Climate Control

EH0533 Indoor Climate Control EH0533 Indoor Climate Control 2.8 kw of cooling, 2.9 kw of heating Air Conditioning Efficient heating (air-source heat-pump) Cooling Remote control Suitable for low-wall installation No external unit required

More information

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850 Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850 Table of Contents Troubleshooting Diagnostic Codes... 2 E1, E2... 2 E3, E4... 3 E5, E6 & E7... 7 E8... 8 E9 9 Verifying Capacity... 10 Water

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 483232 Microprocessor Controller for Energy Recovery Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

Operating instructions Page 12

Operating instructions Page 12 Operating instructions Page 12 Refrigerator with explosion-proof interior container Read the operating instructions before switching on for the first time 7082 271-00 LKEXv 910 Disposal notes The appliance

More information

LevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97

LevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97 LevControl LC PLUS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336 OPERATING INSTRUCTIONS Cod. 71503277/0-12/97 WARNING!!! THE OPERATIONS LISTED BELOW AND THOSE MARKED BY THIS SYMBOL ARE STRICTLY

More information

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE MAX SYSTEM USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

Technical Manual Binair Monobloc Heat Pump

Technical Manual Binair Monobloc Heat Pump Technical Manual Binair Monobloc Heat Pump MODEL BINAIR12 Introduction Disassembly of the machine must be carried out by any professional or any special agency assigned by us. All operation and maintenance

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use. Perfectemp Swimming Pool Heat Pump CE OWNER S MANUAL Models PT4, PT6, and PT8 R C LISTE D 9900276 US This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe

More information

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL MODEL AT105 AT115 AT130 with Titanium Heat Exchanger 2213 Andrea Lane Ft. Myers FL 33912 888-297-3826 941-482-0606 www.aquathermheatpumps.com DIGITAL

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ECB ELECTRIC COMBINATION BOILER ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC

More information

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061 Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061 Imported by: Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www.harmopool.eu 0 Table of content Introduction... 2 Safety instructions...

More information

User s Manual

User s Manual 997-060180-4e User s Manual 8403-060 Menu Driven Display 1120-445 I. CONTROLLER OPERATION ADJUSTING TEMPERATURE (Temporary Override when in Programmable mode) 1. Before you can adjust the temperature,

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

Model 1750A/ 1770A Dehumidifier Installation Instructions

Model 1750A/ 1770A Dehumidifier Installation Instructions Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Conventional and Heat Pump Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE READ ALL

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time Operating instructions Page 14 Refrigerator Read the operating instructions before switching on for the first time 7085 039-00 LKv 5710 Content Disposal notes... 14 Description of the appliance... 14 Safety

More information

Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams DIAGRAM INDEX 50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component

More information

B SERIES ELECTRIC FURNACE

B SERIES ELECTRIC FURNACE MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

USER GUIDE LOGIC HEAT H

USER GUIDE LOGIC HEAT H USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

Installation and Maintenance Manual OM

Installation and Maintenance Manual OM Installation and Maintenance Manual OM 1149-3 Group: WSHP Document PN: 910208203 Date: April 2017 MicroTech III SmartSource Unit Controller with I/O Expansion Module for Single and Two Stage Water Source

More information

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time Operating instructions Page 14 Refrigerator Read the operating instructions before switching on for the first time 7084 309-00 LKUv Disposal notes The appliance contains reusable materials and should be

More information

Model 1870 & 1870W Dehumidifier Installation Instructions

Model 1870 & 1870W Dehumidifier Installation Instructions Model 1870 & 1870W Dehumidifier Installation Instructions SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation

More information

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EXH, EZH) Introduction...4 Remote Thermostat Control...5 Wall Mounted Thermostat Control...11

More information

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M Litho U.S.A. 2 L SERIES UNITS 54,52M /2 Supersedes 54,4M M 6 VERSION 4. INTEGRATED MODULAR CONTROL (IMC) GUIDE TO THE M 6 VERSION 4. INTEGRATED MODULAR CONTROL USED IN L SERIES THROUGH TON UNITS TABLE

More information

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s) Electrical Problems Fuse(s) blow or circuit breaker trips Does the unit use circuit breakers or fuses? Fuse(s) Circuit breakers Are the fuses dual element time delay? Is the circuit breaker HACR rated?

More information

INSTANTANEOUS ELECTRIC SHOWER

INSTANTANEOUS ELECTRIC SHOWER GUARANTEE / SERVICE POLICY INSTANTANEOUS ELECTRIC SHOWER GUARANTEE Designa guarantee this DS3000 product for a period of two years, from date of purchase, against mechanical and electrical defects arising

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE

More information

HP50HA ABG Heat Pump

HP50HA ABG Heat Pump HP50HA ABG Heat Pump Troubleshooting Guide Residential TSG-ABGHPa Copyright 2017 Hayward Industries Inc. Safety Precautions Warning! High Voltage Electrocution Hazard Hazardous voltage can shock, burn,

More information

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO. wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC

More information

FWC860 Wine Cooler Installation, Use and Maintenance

FWC860 Wine Cooler Installation, Use and Maintenance FWC860 Wine Cooler Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W :

More information

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...

More information

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER Printed in the USA ADSOOASHPRAE 0117 Orig SEQUENCE OF OPERATION The ALC controller is turned on by a switch located

More information

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

Installation Instructions

Installation Instructions Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...

More information

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH. THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH www.thermomax-group.com CONTENTS SECTION 1 - INTRODUCTION... 2 SECTION 2 - INSTALLATION... 3 2.1 - RCX 100 UNIT... 4 2.2 -

More information

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER System s30 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER When replacing any part on this appliance, use only spare parts that you can be assured conform to the

More information

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

CWS AIR-CONDITIONERS

CWS AIR-CONDITIONERS CWS AIR-CONDITIONERS MODUL & MODUL XL INSTALLATION, OPERATION AND MAINTENANCE MANUAL MODUL_GB_2007.doc page 1 of 28 10/04/07 CWS air-conditioners 1 - Installation CONTENTS 1 Installation 2 Commissioning

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System Hazardous Location N.E.C. and I.E.C. Approved 50 Hertz Models 60 Hertz, High Ambient, & Custom Designs Available

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

instructions FAN HEATER HVF3533 Please retain these instructions for future reference instructions FAN HEATER HVF3533 Please retain these instructions for future reference Description of Appliance The following terms are used throughout the instruction manual Thermostat Function selector

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL Instruction Manual. SMARTELEC 2 SmartElec ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL 0 F1 INDEX Section General information ------------------------------------------------------------ 1 Dimensions

More information

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System CSA Certified for Use in Division 2 Locations 60 Hertz Models 50 Hertz, High Ambient, & Custom Designs Available

More information

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information