Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Size: px
Start display at page:

Download "Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006"

Transcription

1 Product Data FK4C Direct Expansion Fan Coil Sizes 00 thru 00 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can deliver high-tech performance, application versatility, easy installation, and high efficiency. The FK4C achieves all this by taking full advantage of its programmable integrated controls and motor (ICM2). This versatile motor is completely static independent, meaning the motor will deliver the selected CFM regardless of the duct system, making it the perfect choice for both high and low static applications. Other features homeowners will appreciate are the FK4C s soft ramp up when the unit is turned on, and its soft ramp down after the thermostat is satisfied. These features increase efficiency and eliminate the annoying sounds associated with sudden changes in airflow. The FK4C also features Carrier s patented Easy Select Board. This board streamlines installation and helps the installer to select the correct airflow. The Easy Select Board combined with the ICM2 truly allows dealers to customize the heating and cooling system to each home. The FK4C is also loaded with the most advanced components, so you know it will perform like a premium fan coil should. Inside you will find grooved copper tubing and lanced sine wave aluminum fins, which contribute to the FK4C s high SEER and HSPF ratings. Carrier technology also incorporates boehmited coils, dedicated refrigerant circuitry, and Copyright 995 Carrier Corporation Form FK4C-PD

2 state-of-the-art Thermostatic Expansion Valve (TXV) refrigerant metering. All of this is packed in a rugged, prepainted metal cabinet that is lined with super-thick, high-density insulation. Obviously a unit built to last. In addition to superior quality, the FK4C also offers the ultimate in versatility. Compact and designed for upflow, downflow, and horizontal applications, the FK4C fits right where it is needed. It is equipped with sweat connections and has multiple electric entries for fast, simple installations. Carrier also offers the FK4C with factory- or field-installed electric resistance heat kits in sizes 5kw to 30kw. When the ultimate in efficiency, comfort, and durability is needed, the FK4C is the fan coil to use. Features c Programmable ICM2 blower motor c Easy Select Board c Grooved copper tube c Lanced sine wave aluminum fin c Discreet refrigerant circuits c Prepainted galvanized sheet metal cabinet c Cooling control in every unit c Static independent airflow c Logarithmic spiral blower housings for blower efficiency c High impact thermoplastic condensate pans c All units multipoise c Provision made for suspending from roof or ceiling joists c Modular cabinet design on 00 size c Factory-supplied cleanable, permanent framed filter c Easy access filter no tools required c Field-installed heater packages 5 30 kw, fused, circuit breaker, non-fused (0 kw and down) c Low-voltage terminal block c AMP plug connection provided for accessory heater packages c Connections for humidistat/humidifier c Connections for air cleaner relay c Blower on/off-delay time selections c Extra thick -in., R 4.2 high-density insulation c Tested for condensate disposal at conditions much more severe than those required by ARI c Sweat connections c Bi-flow hard shut-off TXV c Multiple electrical entry c Primary and secondary drain connections with brass inserts c Inspection plate on A-coil models c -/2 5 ton application c HUD approved for manufactured housing c Replaceable 5-amp blade-type auto fuse protects against transformer secondary short c 40 va, 20/230-v transformer c All models listed with UL, cul, ARI and RADCO c Independent fan only selections 2

3 Model number nomenclature F K 4 C N F A A A A Fan Coil Variations ICM Motor, High Efficiency Variations Multipoise Series Series Variations Electrical 20/230/ Heating Size (kw) F High Density, -in. Thick Insulation B Both -in. Thick insulation and Modular Size Designation AN INDEPENDENT LABORATORY ARY AIR CONDITIONING ARY HEAT PUMP CERTIFICATION LISTING TESTING INSPECTION TESTING FOR PUBLIC SAFETY MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 20 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 3

4 Dimensions 7 / 7/ DIA K.O. FOR LOW VOLTAGE CONTROL WIRING NOTES: ALLOW 2.0 FROM FRONT FOR SERVICE. S WITH 20, 24 AND 30 K.W. HEATERS MUST MAINTAIN A MINIMUM OF.0 CLEARANCE FROM DISCHARGE DUCT CLEARANCE TO COMBUSTIBLE MATERIALS. WHEN INSTALLED OVER FINISHED CEILING/LIVING SPACE A FIELD SUPPLIED SECONDARY CONDENSATE PAN MUST BE INSTALLED. 5 / 5/ TOP VIEW 3 / (34.9) 7/, 3 /32 & 2.0 DIA FOR HIGH VOLTAGE POWER WIRING C B DISCONNECT OR CIRCUIT BREAKER LOCATION BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL COIL ACCESS PANEL CONNECTION SIZES SUCTION: 00 & /4 I.D. SWEAT 003, 005 & 00 7 / SWEAT LIQUID: 3 / I.D. SWEAT CONDENSATE PAN CONNECTIONS: 3 /4 FPT UPFLOW/DOWNFLOW HORIZ A-COILS: 3 /4 FEMALE PVC GLUE JOINT VIA FITTINGS PROVIDED. 4 / SUCTION LINE CONNECTION LIQUID LINE CONNECTION LIQUID LINE CONNECTION G OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL S ONLY) INLET AIR ALTERNATE 7/ DIA K.O. FOR LOW VOLTAGE CONTROL WIRING 2 / A 0 3 / 22 / 7/ OUTLET AIR ALTERNATE 7/, 3 /32, 2.0 DIA K.O.'S FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE 3/4 NOTE: MODULAR S WILL HAVE A TWO- PIECE CABINET 2 5 / 0 7 / 5 LIQUID LINE CONNECTION FITTING PANEL SUCTION LINE CONNECTION 3 / 2 3 / 0 3 /4 9 /4 /4 / 9 /2 L MAX K FOR MODULAR S 3/4 OPENING F INLET AIR FILTER ACCESS PANEL FRONT VIEW SHOWN WITH A COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ APPLICATIONS SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN FOR UPFLOW OR HORIZ LEFT APPLICATIONS ACCESS PANEL CONFIG FOR SLOPE COILS DOWNFLOW OR HORIZ RIGHT APPLICATIONS AND A COILS DOWNFLOW APPLICATIONS /4 20 / OPENING RIGHT SIDE VIEW INLET AIR 2 /2 A9530 A B C D E F G SIZE In. In. In. In. In. In. In / 7-5/ 5-3/4 23-3/ 5-3/ / 7-5/ 5-3/4 4-/4-3/ 0-3/4 FK4C / 2-/ 9-/ /2 9-3/ / 2-/ 9-/4 4-5/ 27 9-/2 9-/ / 24-/ 22-3/4 7-3/ 32-/ /4 4

5 Dimensions continued PRIMARY DRAIN AIRFLOW 7 / (4 PLACES) (2 PLACES) AIRFLOW 3 H J 2 3 / (2 PLACES) 7 / PRIMARY DRAIN SECONDARY DRAIN / 2 /2 3 / E 3 / / 2 5 / SECONDARY DRAIN 2 3 / (2 PLACES) / / 3 / / 2 SECONDARY DRAIN PRIMARY DRAIN (2 PLACES) 7 / (4 PLACES) 5 / / / H PRIMARY DRAIN /2 SECONDARY DRAIN /2 3 / 7 / 7 / SECONDARY DRAIN (INSTALL SPECIAL DAM FITTING) PRIMARY DRAIN HORIZ LEFT SLOPE COIL APPLICATION: AS SHIPPED HORIZONTAL MOUNT LOCATIONS DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM, HOLES PROVIDED 0.3 DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. /2 3 / 5 / D HORIZ LEFT A COIL E 3 / APPLICATION: AS SHIPPED SECONDARY DRAIN PRIMARY DRAIN 2 3 / (2 PLACES) UPFLOW SLOPE COIL AIRFLOW 3 / 4 3 / 4 UPFLOW A COIL 7 / (4 PLACES) (2 PLACES) 3 2 / 4 3 / 4 DOWNFLOW SLOPE COIL AIRFLOW H J 3 / PRIMARY DRAIN SECONDARY DRAIN (2 PLACES) 7 / (4 PLACES) DOWNFLOW A COIL APPLICATION: FIELD CONVERTED 2 3 / (2 PLACES) 5 / APPLICATION: FIELD CONVERTED E HORIZ RIGHT SLOPE COIL SECONDARY DRAIN (INSTALL SPECIAL DAM FITTING) 3 / 5 / / 2 3 / 7 D / HORIZ RIGHT A COIL PRIMARY DRAIN A953 SIZE FK4C COIL CONFIGURATION OPERATING WEIGHT H J K L In. In. In. In. SLOPE A Lb /2 7 Yes / -/ Yes / 27-3/ 9 Yes /4 2-5/ Yes / 32-5/ 34-/ Yes 95 5

6 Physical data SIZE * OPERATING WEIGHT (lb) REFRIGERANT R-22 Metering Device TXV TXV SIZE 3 Ton 3 Ton 4 Ton 4 Ton 5 Ton COIL Type Slope A Slope A A Rows Fins/In. 3-4 Face Area (sq ft) FAN Air Discharge Upflow, Downflow, Horizontal 55 / / / / / 225 CFM (Nominal Clg/Htg) 790 / / / / / / / / / / / / / / / 950 MOTOR HP (ECM) /2 /2 /2 /2 3/4 FILTER SIZE 2-/2 x -3/ 2-/2 x -3/ 2-/2 x -7/ 2-/2 x -7/ 2-/2 x 23-5/ * Modular Units Fan coil units with TXV must have a start capacitor and relay for single-phase outdoor units with reciprocating compressor. See outdoor unit presale literature.

7 Performance data FK4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART SIZE OUTDOOR CAPACITY Nominal A/C Cooling Single Speed Application A/C Cooling Dehumidity OPERATING MODE COOLING Nominal A/C Cooling Two-Speed Application High Speed Low Speed A/C Cooling Dehumidify Nominal A/C Cooling NOTE: The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM. Airflow can be adjusted +5% or 0% by selecting HI or LO respectively for all modes except fan only. Dry coil at 230 volts and with 0 kw heater and filter installed. Airflows shown are at standard air conditions. A/C Cooling Dehumidify FAN ONLY Lo/Med/Hi /440/ /455/ /570/ /0/ /440/ /440/ /570/ /0/ /55/ /570/ /0/ /795/ /570/ /0/ /795/ /90/ /745/ /70/ /995/ /240/750 SIZE OUTDOOR CAPACITY FK4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART Heat Pump Comfort Single Speed Application Heat Pump Efficiency NOTE: The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM. Airflow can be adjusted +5% or 0% by selecting HI or LO respectively. Dry coil at 230 volts and with 0 kw heater and filter installed. Airflows shown are at standard air conditions. OPERATING MODE HEAT PUMP ONLY HEATING Heat Pump Comfort Two-Speed Application High Speed Low Speed Heat Pump Efficiency Heat Pump Comfort Heat Pump Efficiency

8 Performance data continued AIRFLOW DELIVERY CHART (cfm) ELECTRIC HEATING MODES SIZE 00, OUTDOOR ELECTRIC HEATER KW RANGE CAPACITY BtuH Lo Nom Hi Lo Nom Hi Lo Nom Hi Lo Nom Hi, * * * * * * * * * 24, * * * * * * 30, , , * * * * * * 30, * * * 3, , SIZE OUTDOOR ELECTRIC HEATER KW RANGE CAPACITY BtuH Lo Nom Hi Lo Nom Hi Lo Nom Hi Lo Nom Hi 30, * * * * * * 3, * * * 42, , , * * * * * * 42, * * * 4, , * Airflow not recommended for heater/system size. NOTE: LO, NOM and HI refer to the AC/HP CFM ADJUST selection. MINIMUM CFM FOR ELECTRIC HEATER APPLICATION SIZE 00, HEAT PUMP SIZE CFM Heater Size KW 5, 9, 0 5, 20 24, 30 Heater Only Heater Only Heater Only Heater Only NOTE: Heater Only Air Conditioner with electric heater application. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per the airflow delivery chart for Electric Heating Modes.

9 The airflow performance charts for the FK4C fan coil depict nominal airflow delivery for heating and cooling mode operation versus duct system static pressure drop. Cooling mode operation is shown as solid vertical lines for all four system size selections. Heating mode operation for the four system size selections are shown as dashed vertical lines. The dotted curved lines are static pressure drop characteristics for several fixed-duct systems. These lines can be used to predict the system static pressure drop at any airflow given the actual drop at one known point. For example, a duct system is designed for.5 inches water gage (iwg) drop at 200 CFM. The FK4CNF005 operating at nominal cooling airflow would deliver 050 CFM with a duct system drop of. iwg (see point ). The FK4CNF005 operating at nominal heating airflow would deliver 945 CFM at a duct system drop of.09 iwg (see point 2). This example is but one of many possible duct system designs. The FK4CNF005 will deliver the above airflows against much higher static pressures. AIRFLOW PERFORMANCE FKACNF005 NOM. CLG EXTERNAL STATIC PRESSURE (iwg).5 DUCT SYSTEMS NOM. HTG SCFM A9539 9

10 AIRFLOW PERFORMANCE FK4CNF00 NOMINAL COOLING NOMINAL HEATING HI COOLING 0.7 EXTERNAL STATIC PRESSURE (iwg) SCFM A

11 AIRFLOW PERFORMANCE FK4CNF002 NOMINAL COOLING NOMINAL HEATING 03 HI COOLING EXTERNAL STATIC PRESSURE (iwg) SCFM A95324

12 .4 AIRFLOW PERFORMANCE FK4CNF003 NOMINAL COOLING NOMINAL HEATING HI COOLING EXTERNAL STATIC PRESSURE (iwg) SCFM A

13 .4.3 AIRFLOW PERFORMANCE FK4CNF005 NOMINAL COOLING NOMINAL HEATING EXTERNAL STATIC PRESSURE (iwg) HI COOLING SCFM A9532 3

14 ..7 AIRFLOW PERFORMANCE FK4CNB00 NOMINAL COOLING NOMINAL HEATING HI COOLING. EXTERNAL STATIC PRESSURE (iwg) SCFM A

15 Performance data continued COOLING CAPACITIES (MBtuh) SIZE EVAPORATOR AIR Cfm BF See notes on pg.. COIL REFRIGERANT TEMPERATURE ( F) Evaporator Air Entering Wet-Bulb Temperature ( F)*

16 * Saturated suction leaving evaporator coil. BF Bypass Factor Sensible Heat Capacity NOTES:. Net capacities shown include a deduction for evaporator fan motor heat. 2. Contact manufacturer for cooling capacities at conditions other than shown in table. 3. Formulas: sensible heat cap. Leaving db = entering db.09 x cfm Leaving wb = wb corresponding to enthalpy of air leaving coil (h lwb ) total capacity (Btuh) h lwb = h ewb 4.5 x cfm where h ewb = enthalpy of air entering coil. 4. Direct interpolation is permissible. Do not extrapolate. 0 F subtract (corr factor x cfm) from SHC. Above 0 F db, add (corr factor x cfm) to SHC. BYPASS FACTOR SHC Correction Factor ENTERING AIR DRY-BULB TEMPERATURE ( F) Under Over 5 Correction Factor Interpolation is permissible. Correction Factor =.09 x ( BF) x (db 0) Use formula shown below 5. SHC is based on 0 F db temperature of air entering coil. Below Performance data continued ESTIMATED SOUND POWER LEVEL* SIZE CONDITIONS OCTAVE BAND CENTER FREQUENCY CFM ESP RPM * Estimated sound power levels have been derived using the method described in the 97 ASHRAE Systems & Applications Handbook, chapter 52, p CFM Cubic Feet Per Minute ESP External Static Pressure RPM Revolutions Per Minute

17 Performance data continued AIRFLOW PERFORMANCE CORRECTION FACTORS The FK4C airflow performance table was developed using fan coils with 0 kw electric heaters (2 elements) in the units. For fan coils with heaters made up of a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use table for this correction. STATIC PRESSURE CORRECTION (in. wc) HEATER KW ELEMENTS Sizes Size , , , 24, * Inches water column FILTER STATIC PRESSURE DROP (In. wc)* CFM SIZE AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY TO WET COIL) CFM SIZE NOTE: Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. CFM

18 Accessories ITEM ACCESSORY P/N* FAN COIL SIZE USED WITH FK4C- Disconnect Kit KFADK00DSC Cooling controls and heaters through 0 kw Coil Brkt Kit (Downflow Slope) KFADC020SLP 00, 003 Coil Brkd Kit (Downflow A) KFADC030ACL 002, 005, 00 Downflow Base Kit KFACB020CFB 00, 002 Downflow Base Kit KFACB030CFB 003, 005 Downflow Base Kit KFACB040CFB 00 Filter Kit (2 Pack) KFAFK022MED 00, 002 Filter Kit (2 Pack) KFAFK032LRG 003, 005 Filter Kit (2 Pack) KFAFK042XXL 00 Single-Point Wiring Kit KFASP00SPK All Air Cleaner Relay Kit KFAIR020ACR All *Factory authorized and listed, field installed. Accessory Description and Usage. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: FK4, FC4, FB4, FA4, and FH4 units for 3 kw through 0 kw electric resistance heaters and cooling controls. 2. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils. REQUIRED USE: This kit must be used whenever FK4, FC4, FB4, and FA4 fan coils are used in downflow applications. 3. Downflow Base Kit This kit is designed to provide a in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap free seal with the floor. REQUIRED USE: This kit must be used whenever FK4, FC4, FB4, FA4, and FH4 fan coils are used in downflow applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between L and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy-gage, high-voltage wires into the fan coil rather than 4 light-gage, high-voltage wires. SUGGESTED USE: FK4, FC4, FB4, FA4, and FH4 fan coils only with 5 kw and 20 kw heaters 5. Air Cleaner Relay The electronic air cleaner relay ensures the FK4C fan coil and electronic air cleaner work as a system. REQUIRED USE: This relay is required whenever an electronic air cleaner is used with an FK4C fan coil.. Fan Coil Filter The kit consists of fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system. SUGGESTED USE: To replace the filters in FK4, FC4, FB4, and FH4 fan coils. REQUIRED USE: All FA4A units unless a filter grille is used.

19 Electrical data S WITHOUT ELECTRICAL HEAT SIZE VOLTS-PHASE FLA MIN CKT AMPS Min Wire Size Awg* BRANCH CIRCUIT Max Wire Length (ft) 00 20/ / / / / * Use copper wire only to connect unit. If other than uncoated (nonplated) 75 F ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used consult applicable tables of the National Electric Code (ANSI/NFPA 70). Length shown is as measured way along wire path between unit and service panel for a maximum 2% voltage drop. FLA Full Load Amps 20v 230v Fuse Amps Accessory electric heaters ELECTRIC HEATERS HEATER P/N 240V VOLTS/PHASE KW/ STAGE INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING 230V KFAEH020N / 5 None** All 5,700 KFAEH030N0 230/ None** All 25,00 KFAEH040N / 0 None** All 3,400 KFAEH20F / 5, 0 Fuses All 47,00 KFAEH00F / 0, 0 Fuses All 2,00 KFAEH250N /* 3, None** All 2,300 KFAEH /3 5, 0 None** All 47,00 KFAEH /3,, None** 003, 005, 00 5,500 KFAEH00F /3,, Fuses 005, 00 7,500 KFAEH0F /3 0, 0, 0 Fuses 005, 00 94,200 KFAEH30C / 5 Ckt Bkr** All 5,700 KFAEH40C0 230/ Ckt Bkr** All 25,00 KFAEH50C / 0 Ckt Bkr** All 3,400 KFAEH20C / 5, 0 Ckt Bkr** All 47,00 KFAEH70C / 0, 0 Ckt Bkr** All 2,00 KFAEH270S / 5, 0 Fused All 47,00 KFAEH90S / 0, 0 Fused All 2,00 * These heaters field convertable to three phase. These heaters field convertable to single phase. Blower motor heat not included. ** cul approved. ELECTRIC HEATER INTERNAL PROTECTION HEATER KW PHASE FUSES QTY/SIZE CKT BKR QTY/SIZE 5 2/0 2/0 0 2/0 5 2/30, 2/0 4/0 20 4/0 4/0 24 3/ /0 30 3/ /0 9

20 Electric heater electrical data ELECTRIC HEATER ELECTRICAL DATA ACCESSORY HEATER P/N KFAEH00N03 KFAEH20C03 KFAEH020N05 KFAEH30C05 KFAEH030N0 KFAEH40N0 KFAEH250N09 KFAEH040N0 KFAEH50C0 KFAEH20F5 KFAEH270S5 KFAEH20C5 KFAEH0035 KFAEH0903 KFAEH00F20 KFAEH90S20 KFAEH70C20 KFAEH00F24 KFAEH0F30 kw 240V 20V PHASE INTERNAL CIRCUIT PROTECTION CB CB CB CB FUSE FUSE CB FUSE FUSE CB FUSE FUSE FUSE FUSE SINGLE CIRCUIT 0.9/ /2.0./20.0./ / /32.0./ / / / / / / / / /55.4.7/ / / 20.0 HEATER AMPS 20/230V DUAL CIRCUIT L, L2 L3, L4 3.2/ / / / / /40.0./20.0./20.0./ / / /40.0 SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4.2/7.5.2/ / / / / / / / /. 74.7/. 4.0/ / / /0. 9.5/7.2.0/ / /57.0 MIN AMPACITY* 20/230V 52.2/ / / / / / / / / / / /50.0 MIN WIRE SIZE (AWG) 20/230V SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L / 3/2 3/2 0/ BRANCH CIRCUIT MIN GND WIRE SIZE 20/230V SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L /0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 FUSE/CKT BKR AMPS 20/230V SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L /30 25/30 45/50 45/ / / /0 94/9 35/35 0/0 0/0 0/90 0/90 50/50 0/0 00/0 00/0 70/0 25/50 90/00 50/75 0/0 0/0 0/0 0/0 0/0 0/0 25/25 25/25 25/25 50/50 50/50 50/50 MAX WIRE LENGTH** FOR 2% VOLTAGE DROP 20/230V (FT) SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4 3/5 3/5 /2 /2 /2 /2 0/ 7/79 7/79 /7 /7 7/2 94/95 4/0 4/0 /7 2/3 20/2 4/45 7/79 7/79 7/79 7/79 7/79 7/79 7/79 7/79 7/79 5/5 5/5 5/5 FIELD MULTIPOINT WIRING OF 24- AND 30-KW SINGLE PHASE HEATER PART NO. KW 240V 20V PHASE HEATER AMPS 20/230V MIN AMPACITY 20/230V* MIN WIRE SIZE (AWG) 20/230V MIN GND WIRE SIZE 20/230V FUSE/CKT BKR AMPS 20/230V MAX WIRE LENGTH** FOR 2% VOLTAGE DROP 20/230V (FT) L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L KFAEH00F / / / /4.9 3./ / /50 40/45 40/45 /2 73/73 73/73 KFAEH0F / / / / / / /0 50/0 50/0 7/79 5/5 5/5 * ** CB Circuit Breaker Includes blower motor amps of largest fan coil is used with heater. CSA fused with single point wiring adapter Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used, consult applicable tables of the National Electronic Code (ANSI/NFPA 70). Length is as measured one way along wire path between unit and service panel for a maximum voltage drop not to exceed 2%. NOTE: The 24- and 30-kw heaters are convertible to -phase, single or multiple supply circuit. The 9-kW heaters are convertable to three phase. Single circuit application of F5 and F20 heaters requires single-point wiring kit accessory. A

21 Matched system HEAT PUMP HUMIDIFIER FAN COIL AIR FLOW ELECTRONIC AIR CLEANER A9202 2

22 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG [ ] Packaged Service Training [ ] Classroom Service Training A9432 Copyright 995 Carrier Corporation Syracuse, New York Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 4 Page 22 Catalog No FK-4CC Printed in U.S.A. PC 0 Form FK4C-PD Tab 3d 2e Replaces: FK4B-PD

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3 DIRECT EXPANSION FAN COIL MODEL FK4C Sizes 001 thru 006 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can

More information

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006 Product Data FK4D Direct Expansion Variable Speed Fan Coil Sizes 001 thru 006 A02332 FK4D Premium Air Handling Technology The FK4D is the latest in air handling technology. It is the perfect unit when

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006 Product Data FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler available.

More information

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler

More information

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal Product Data 40FKA Comfort Heat Pump System Fan Coil Sizes 002 thru 006 THERMIDISTAT CONTROL OUTDOOR TEMPERATURE SENSOR 40FKA FAN COIL Comfort Heat Pump System Fan Coil and Thermidistat Control Revolutionizing

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

FAN UNIT FH4A Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004 FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg) FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating

More information

FCM4X. Product Specifications

FCM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FCM4X Product Specifications FAN COILS WITH OBSERVER COMMUNICATING CONTROL Smart Diagnostics Easier troubleshooting, providing faster service and repair Environmentally

More information

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally

More information

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST Base Series Fan Coil Sizes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST A10082 The fan coil combines the proven technology of Carrier fan coil units with the flexibility to handle both

More information

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 001 thru 004 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The series fan coils are reliable, dependable, and a great value. These fan coils offer air handling for practical,

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006 FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND

More information

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 024, 036, 048 and 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The direct expansion fan coils are designed to cover a wide range of air handling requirements. They are compact

More information

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat

More information

FXM4X. Product Specifications FAN COILS FXM4X

FXM4X. Product Specifications FAN COILS FXM4X ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper

More information

FEM4X. Product Specifications FAN COILS /14/15

FEM4X. Product Specifications FAN COILS /14/15 ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator

More information

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device

More information

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation Product Data 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces 58BLA Low-Boy AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY ama 58BMA 3-Way Multipoise 58BTA Upflow/Horizontal Copyright 1996 Carrier Corporation

More information

Dimensions H x W x D in. (mm)

Dimensions H x W x D in. (mm) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST , Base eries Fan Coil izes 018 Thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The and direct-expansion fan coils are designed to cover a wide range of air handling requirements. They are compact

More information

WAHL A Product Specifications

WAHL A Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price Product Data 58PAV Energy-Efficient Induced-Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80 percent Annual Fuel Utilization Efficiency

More information

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL Product Data CF5A COILS KMABA BLOWERS For Manufactured Homes THE CF5A INDOOR COIL To complete your cooling or heating system, the model CF5A Coil is installed inside your Evcon/Coleman, Nordyne/Miller/Intertherm,

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

REM4P, REM4X. Product Specifications

REM4P, REM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling Product Data 28CB, Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Direct-expansion evaporator coils easily accommodate upflow or horizontal light-commercial applications Features/Benefits

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK

More information

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST PF4MNP FAN COIL IZE 018 THRU 060 Product Data The PF4MNP fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling Product Data 28CB, 28LA Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Copyright 2001 Carrier Corporation 28LA Direct-expansion evaporator coils that easily accommodate upflow

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006 FE4A, FE5A Infinityt eries Communicating Variable---peed Fan Coil Puronr Refrigerant izes 002 thru 006 Product Data PREMIUM ENVIRONMENTALLY -OUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET A10082 The fan coil has the proven technology of Carrier fan coil units with Puron refrigerant as well as vertical

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Product Data. HUM Humidifiers

Product Data. HUM Humidifiers Product Data HUM Humidifiers Model HUMCCLFP1025-A-- Model HUMCCSFP1016-A-- Model HUMCCLBP2018-A-- Model HUMCCWTR2019-A-- Model HUMCCSBP2017-A-- All Carrier humidifiers are designed for easy installation

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3 FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Table of Contents. Page 2

Table of Contents. Page 2 FB4P Fan Coil Units 60Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing Co. Ltd. Country

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

Models 566D 569C,576B with 524A 6to30Tons

Models 566D 569C,576B with 524A 6to30Tons Bryant Air Conditioning COMMERCIAL AIR-COOLED CONDENSING S WITH 524A AIR-HANDLING S Models 566D 569C,576B with 524A 6to30Tons DESCRIPTION Model 569C condensing units are available in nominal 6- to 10-ton

More information

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006 FE4A, FE5A Infinityt eries Communicating Variable---peed Fan Coil Puronr Refrigerant izes 002 thru 006 Product Data PREMIUM ENVIRONMENTALLY -OUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

Product Data MECH. Mechanical Filter Air Cleaner

Product Data MECH. Mechanical Filter Air Cleaner Product Data MECH Mechanical Filter Air Cleaner Carrier s long and successful history of HVAC innovation continues with the introduction of a new air cleaner product line. Now available to distribution

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A-- HUMIDIFIERS MODELS HUM HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A-- All Bryant humidifiers are designed for easy installation and quiet operation with heat pumps

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information