IMC-700 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES

Size: px
Start display at page:

Download "IMC-700 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES"

Transcription

1 IMC-700 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES

2 TALE OF CONTENTS HEATER INSTALLATION Page 8 (Thermosiphon) Page 47 (In-block) HOW TO SPECIFY AN ENGINE HEATER Page 50 CONVERSION CHARTS Page 50 CUSTOM PRODUCTS Call for information on: Wiring Harnesses APUs Forced Circulation Heating Systems Other Specialty Products PAGES 4-5 HOTflow Engine Heaters CTM, CSM Models PAGES 6 - Thermosiphon Engine Heaters Weathertight Design TPS, C, CL, WL, S, SL Models PAGES 4-7 Thermosiphon Engine Heaters Hazardous Location EE Models PAGES Lube Oil Heaters (AC and DC) Industrial Immersion Heaters Thread-in and Threadless Models PAGES 27-2 Remote Thermostats for Lube Oil Heaters Temperature Controls for Thermosiphon Engine Heaters Complete Control Systems PAGES 4-6 attery Warming Pads & Accessories lanket Style attery Warmers Silicone Hot Pads PAGES 8-49 In-block Heaters Electrical Cords for In-block Heaters Thermocords Flush Mount Kits and Accessories

3 SECTION HOTflow and THERMOSIPHON ENGINE HEATERS

4 HOTflow Engine Heaters CTM Model Single Phase Engine Size CID/Liter L Power Supply Volts Ø Hz 20 Model Number kw Amps CTM w/8 (2.4m) cord and NEMA plug* 50/ CTM00-N00 CTM020-N Thermostat Range On Off 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) Watts L 20 50/ CTM50-N00 CTM520-N F (8C) 20 F (49C) 00 F (8C) 20 F (49C) L 20 50/ CTM250-N00 CTM2520-N F (8C) 20 F (49C) 00 F (8C) 20 F (49C) Meets requirements for installation on any UL 2200 listed generator L 20 CTM w/9.8 (m) cord, without plug 50/ CTM00-A00 CTM020-A F (8C) 20 F (49C) 00 F (8C) 20 F (49C) L 20 50/ CTM50-A00 CTM520-A F (8C) 20 F (49C) 00 F (8C) 20 F (49C) L 20 50/ CTM250-A00 CTM2520-A F (8C) 20 F (49C) 00 F (8C) 20 F (49C) CTM w/9.8 (m) cord and Schuko plug (Euro)** Isolation Mounting Kit (optional) CTM-IMK L L L 50/ CTM020-E F (8C) 20 F (49C) 50/ CTM520-E F (8C) 20 F (49C) 50/ CTM2520-E F (8C) 20 F (49C) * - UL/C-US listed Other voltages available. Consult the factory. ** - CE compliant HOTSTART s HOTflow engine heater (CTM Model) features an integrated pump that combines the benefits of forced circulation with a compact design that can mount to a variety of small engine applications. Forced circulation of the coolant delivers uniform heating throughout the entire engine, extends element life and offers a significant reduction in electrical consumption. H W Height (H) Width (W ) Width2 (W 2 ) Weight lbs. 20mm 45mm 6mm.6 kg W 2 4 Customer Service: hotstart.com

5 Engine Size CID/Liter L L L L Power Supply Volts Ø Hz * CE compliant/union pump configuration Other voltages available. Consult the factory. Model Number kw Amps Style CSM CSM CSM * CSM00J-5A0 CSM CSM CSM CSM CSM * CSM0J-5A0 CSM * CSM0A-5A0 * CSM0F-5A CSM CSM CSM CSM CSM * CSM090J-5A0 CSM * CSM090A-5A0 * CSM090F-5A CSM CSM CSM CSM CSM-000 * CSM20J-5A0 CSM * CSM20A-5A0 * CSM20F-5A0 CSM CSM CSM A A A A A A A A A A Thermostat Range On Off 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) HOTflow Engine Heaters CSM Model Single & Three Phase 000- Watts Meets requirements for installation on any UL 2200 listed generator. HOTSTART s HOTflow engine heater (CSM Model) features a thermostat, pump and all required controls. Forced circulation of the coolant delivers uniform heating throughout the entire engine, extends element life and offers a significant reduction in electrical consumption. The HOTflow CSM operates automatically when provided contacts are supplied with a 24 V DC signal from the engine. * * Style A Style H H W D W D Height (H) Width (W) Depth (D) Weight lbs. 8mm 49mm 242mm 6.8 kg Height (H) Width (W) Depth (D) Weight lbs. 44mm 49mm 242mm 24.5 kg * If a union-style pump is installed, the model s height (H) will decrease by approximately.5 (8mm) Customer Service: hotstart.com 5

6 Thermosiphon Engine Heaters Engine Displacement Watts Model Number 20V Amps Model Number V Amps Model Number 277V Amps TPS Model Single Phase 50cid 2.5L 500 TPS05GT8-000 TPS05GT0-000 TPS05GT TPS052GT8-000 TPS052GT0-000 TPS052GT0-0 TPS052GT TPS057GT Watts 50cid 5.7L 000 TPS0GT8-000 TPS0GT0-000 TPS0GT TPS02GT8-000 TPS02GT0-000 TPS02GT0-0 TPS02GT TPS07GT cid L 500 TPS5GT8-000 TPS5GT0-000 TPS5GT TPS52GT8-000 TPS52GT0-000 TPS52GT0-0 TPS52GT TPS57GT Temperature Range ON OFF 80 F (27C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 40 F (C) Numerical Code cid L 800 TPS8GT8-000 TPS8GT0-000 TPS8GT TPS202GT8-000 TPS202GT0-000 TPS202GT0-0 TPS202GT TPS207GT Power cord length on all models 48 (29mm) TPS engine preheaters include a fixed setting thermostat. A single or double digit numeral at the end of the model number prefix designates the temperature range. Example: TPS0GT0-000 (see chart in left column) -0 Engine preheater features 2 meter round cord and Shucko plug - CE compliant Replacement Parts Replacement Tank For TPS Models Model Number TPS05GT8-000 TPS05GT0-000 TPS05GT2-000 TPS052GT8-000 TPS052GT0-000 TPS052GT0-0 TPS052GT2-000 TPS057GT0-000 Sensing Unit LSU-8 LSU-0 LSU-2 LSU-8 LSU-0 LSU-0 LSU-2 LSU-0 Replacement Parts Element Tank ox REPS05T8 REPS05T0 REPS05T2 REPS052T8 REPS052T0 REPS052T0 REPS052T2 REPS057T0 CPS- CPS- CPS- CPS- CPS- CPS-2 CPS- CPS- Power Cord P48UU P48UU P48UU 2P48UU 2P48UU 2SCH8UU 2P48UU 6H48UU Element O-ring Replacement Element Element O-Ring TPS0GT8-000 TPS0GT0-000 TPS0GT2-000 TPS02GT8-000 TPS02GT0-000 TPS02GT0-0 TPS02GT2-000 TPS07GT0-000 LSU-8 LSU-0 LSU-2 LSU-8 LSU-0 LSU-0 LSU-2 LSU-0 REPS0T8 REPS0T0 REPS0T2 REPS02T8 REPS02T0 REPS02T0 REPS02T2 REPS07T0 CPS- CPS- CPS- CPS- CPS- CPS-2 CPS- CPS- P48UU P48UU P48UU 2P48UU 2P48UU 2SCH8UU 2P48UU 6H48UU Sensing Unit Replacement Cord Replacement ox TPS5GT8-000 TPS5GT0-000 TPS5GT2-000 TPS52GT8-000 TPS52GT0-000 TPS52GT0-0 TPS52GT2-000 TPS57GT0-000 TPS8GT8-000 TPS8GT0-000 TPS8GT2-000 LSU-8 LSU-0 LSU-2 LSU-8 LSU-0 LSU-0 LSU-2 LSU-0 LSU-8 LSU-0 LSU-2 REPS5T8 REPS5T0 REPS5T2 REPS52T8 REPS52T0 REPS52T0 REPS52T2 REPS57T0 REPS8T8 REPS8T0 REPS8T2 CPS- CPS- CPS- CPS- CPS- CPS-2 CPS- CPS- CPS- CPS- CPS- P48UU P48UU P48UU 2P48UU 2P48UU 2SCH8UU 2P48UU 6H48UU 2P6H48UU 2P6H48UU 2P6H48UU TPS202GT8-000 TPS202GT0-000 TPS202GT0-0 TPS202GT2-000 TPS207GT0-000 LSU-8 LSU-0 LSU-0 LSU-2 LSU-0 REPS202T8 REPS202T0 REPS202T0 REPS202T2 REPS207T0 CPS- CPS- CPS-2 CPS- CPS- 2P48UU 2P48UU 2SCH8UU 2P48UU 6H48UU 6 Customer Service: hotstart.com

7 Engine Displacement Model Number Volts Watts Phase Amps Thermostat Range On Off Thermosiphon Engine Heaters 50cid 2.5L 50cid 5.7L TPS05GT2-00 TPS05GT2-A00 TPS052GT2-00 TPS052GT2-A00 TPS0GT2-00 TPS0GT2-A00 TPS02GT2-00 TPS02GT2-A F (8C) 20 F (49C) ADJUSTALE 00 F (8C) 20 F (49C) ADJUSTALE 00 F (8C) 20 F (49C) ADJUSTALE 00 F (8C) 20 F (49C) ADJUSTALE TPS Model w/in-line adjustable and remote thread-in fixed thermostat. Single Phase cid L TPS5GT2-00 TPS5GT2-A00 TPS52GT2-00 TPS52GT2-A F (8C) 20 F (49C) ADJUSTALE 00 F (8C) 20 F (49C) ADJUSTALE cid L TPS8GT2-00 TPS8GT2-A00 TPS202GT2-00 TPS202GT2-A Remote thread-in fixed temperature thermostat F (8C) 20 F (49C) ADJUSTALE 00 F (8C) 20 F (49C) ADJUSTALE Adjustable 90-0 F (2-54 C) On differential 20 F (-7 C) Remote Adjustable Thermostat Assembly Part Number TFTA-5/8H In-line thermostat options: Power Y-cord OUTLET HOSEAR I.D (4X) Holes For Mounting rackets.5 8mm Adjustable Thermostat Assembly mm mm mm Thermostat Well In-Line Adjustable Thermostat INLET HOSEAR I.D mm Remote Thread-in Fixed Temperature Thermostat Model Number TPS05GT2-00 TPS05GT2-A00 TPS052GT2-00 TPS052GT2-A00 TPS0GT2-00 TPS0GT2-A00 TPS02GT2-00 TPS02GT2-A00 TPS5GT2-00 TPS5GT2-A00 TPS52GT2-00 TPS52GT2-A00 Volts Watts Sensing Unit LSU-0 RSU90-0 LSU-0 RSU90-0 LSU-0 RSU90-0 LSU-0 RSU90-0 LSU-0 RSU90-0 LSU-0 RSU90-0 Element REPS05T2 REPS05T2 REPS052T2 REPS052T2 REPS0T2 REPS0T2 REPS02T2 REPS02T2 REPS5T2 REPS5T2 REPS52T2 REPS52T2 Replacement Parts Power Y-cord TPS-YC # TPS-YC2 # TPS-YC # TPS-YC2 # TPS-YC # TPS-YC2 # Thermostat Well TW274- # TW274- # TW274- # TW274- # TW274- # TW274- # Replacement Parts For TPS Model w/in-line adjustable and remote thread-in fixed thermostat. Single Phase Common replacement parts for all TPS engine preheaters: Tank ox Element O-ring TPS8GT2-00 TPS8GT2-A00 TPS202GT2-00 TPS202GT2-A LSU-0 RSU90-0 LSU-0 RSU90-0 REPS8T2 REPS8T2 REPS202T2 REPS202T2 2P6H54S54X0UU # TPS-YC2 # TW274- # TW274- # See table on page 6-00 Remote thread-in fixed temperature thermostat # Call Factory Customer Service: hotstart.com 7

8 Thermosiphon Engine Heaters Engine Displacement Model Number without Thermostat Model Number with Thermostat see chart Volts Watts Phase Amps C, CL Model Weathertight Single Phase cid L C C C C C C C5XX-200 C58XX-200 C52XX-200 C57XX-200 C5XX-200 C54XX Watts 500-0cid L C-000 C C C-000 C C20XX-200 CXX-200 C202XX-200 C20XX-200 C204XX cid L C C C C C C C25XX-200 C258XX-200 C252XX-200 C257XX-200 C25XX-200 C254XX cid L CL CL CL CL CL CL CL0XX-200 CL08XX-200 CL02XX-200 CL07XX-200 CL0XX-200 CL04XX C Model without thermostat cid L CL CL CL CL CL CL408XX-200 CL402XX-200 CL407XX-200 CL40XX-200 CL404XX cid L CL CL CL CL CL CL508XX-200 CL502XX-200 CL507XX-200 CL50XX-200 CL504XX C Model assembled with thermostat CL Model without thermostat CL Model assembled with thermostat CHART Heaters with Thermostats To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temp. Range: F Model Number: C5XX-200 Order as: C Temperature Range ON 80 F (27C) 00 F (8C) 20 F (49C) OFF 00 F (8C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Numerical Code A C Model INLET, NPT FEMALE INLET, NPT FEMALE CL Model 6.2 4mm mm mm mm mm ADJUSTALE OUTLET, NPT FEMALE OUTLET, NPT FEMALE OUTLET, NPT FEMALE 4. 09mm 5.2 2mm mm 4. 04mm 5. 29mm 5.25 mm INLET, NPT FEMALE mm ADJUSTALE OUTLET, NPT FEMALE mm mm INLET, NPT FEMALE 8 Customer Service: hotstart.com

9 Model Number without Thermostat Model Number with Thermostat see chart 2 Replacement Parts Element Tank ox Element O-ring Mounting rackets Replacement Parts C C C C C C C5XX-200 C58XX-200 C52XX-200 C57XX-200 C5XX-200 C54XX-200 REC5 REC58 REC52 REC57 REC5 REC54 RT RT RT RT RT RT RTC RTC RTC RTC RTC RTC RTMM RTMM RTMM RTMM RTMM RTMM For thermosiphon engine heaters C, CL Model C-000 C C C-000 C C20XX-200 CXX-200 C202XX-200 C20XX-200 C204XX-200 REC20 REC REC202 REC20 REC204 RT RT RT RT RT RTC RTC RTC RTC RTC RTMM RTMM RTMM RTMM RTMM Common Replacement Parts available on all listed heaters High Limit Control Check Valve C C C C C C C25XX-200 C258XX-200 C252XX-200 C257XX-200 C25XX-200 C254XX-200 REC25 REC258 REC252 REC257 REC25 REC254 RT RT RT RT RT RT RTC RTC RTC RTC RTC RTC RTMM RTMM RTMM RTMM RTMM RTMM HLC-65 CHART 2 RV-M CL CL CL CL CL CL CL0XX-200 CL08XX-200 CL02XX-200 CL07XX-200 CL0XX-200 CL04XX-200 RECL0-00 RECL08-00 RECL02-00 RECL07-00 RECL0-00 RECL04-00 RTL RTL RTL RTL RTL RTL RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK7 FK7 FK7 FK7 FK7 FK7 Heaters with Thermostats Temperature Range ON OFF Sensing Unit CL CL CL CL CL CL CL CL CL CL CL408XX-200 CL402XX-200 CL407XX-200 CL40XX-200 CL404XX-200 CL508XX-200 CL502XX-200 CL507XX-200 CL50XX-200 CL504XX-200 RECL RECL RECL RECL40-00 RECL RECL RECL RECL RECL50-00 RECL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK7 FK7 FK7 FK7 FK7 FK7 FK7 FK7 FK7 FK7 80 F (27C) 00 F (8C) 20 F (49C) 00 F (8C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Example: FSU8 FSU0 FSU2 FSU90-0 Model Number: C T-Stat Replacement: FSU0 C Model with thermostat assembly Element O-Ring Temperature Sensing Unit Mounting rackets Replacement Tank Replacement Element High Limit Control Replacement ox ADAPTER FITTINGS For the use of 0.75 or ID heater hose, hose barb adapters are available. See below. H- NPT to hose barb adapter. Installs in NPT female inlet or outlet of the heater. Check Valve Check Valve Mounting rackets Replacement Tank H-/4 NPT to 0.75 hose barb adapter. Installs in NPT female inlet or outlet of the heater. Element O-Ring Temperature Sensing Unit CL Model with thermostat assembly Customer Service: hotstart.com 9

10 Thermosiphon Engine Heaters Engine Displacement Model Number without Thermostat Model Number with Thermostat see chart Volts Watts Phase Amps S, SL Series With power cord Weathertight Single Phase Watts cid L 500-0cid L S S S S S-000 S S S5XX-200 S58XX-200 S52XX-200 S57XX-200 S20XX-200 SXX-200 S202XX cid L S S S S S22XX-200 S258XX-200 S252XX-200 S257XX cid L SL SL SL SL08XX-200 SL02XX-200 SL07XX cid L SL SL SL SL408XX-200 SL402XX-200 SL407XX Power cord length on all models 72 (829mm) All V and 277 V models come with cord only - no plug. S Model with power cord no thermostat S Model with thermostat and power cord CHART Heaters with Thermostats To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temp. Range: F Model Number: S5XX-200 Order as: S Temperature Range ON 80 F (27C) 00 F (8C) 20 F (49C) OFF 00 F (8C) 20 F (49C) 40 F (C) Numerical Code S Model INLET, NPT FEMALE INLET, NPT FEMALE mm mm mm mm OUTLET, NPT FEMALE OUTLET, NPT FEMALE 4. 09mm 5.2 2mm 4. 04mm 5. 29mm Adjustable 90-0 F (2-54 C) A SL Model SL Model with power cord no thermostat mm ADJUSTALE OUTLET, NPT FEMALE 5.25 mm mm INLET, NPT FEMALE mm ADJUSTALE OUTLET, NPT FEMALE mm SL Model with thermostat and power cord mm INLET, NPT FEMALE 0 Customer Service: hotstart.com

11 Model Number without Thermostat Model Number with Thermostat see chart 2 Element Tank ox Replacement Parts Power Cord Element O-ring Mounting rackets Replacement Parts S S S S S5XX-200 S58XX-200 S52XX-200 S57XX-200 RES5 RES58 RES52 RES57 RT RT RT RT RTS RTS RTS RTS RH--5 RH-WOP RH-2-5 RH-WOP RTMM RTMM RTMM RTMM For thermosiphon engine heaters S, SL Series S-000 S S S20XX-200 SXX-200 S202XX-200 RES20 RES RES202 RT RT RT RTS RTS RTS RH--20 RH-WOP RH-2-5 RTMM RTMM RTMM Common Replacement Parts available on all listed heaters S S S S S22XX-200 S258XX-200 S252XX-200 S257XX-200 RES22 RES258 RES252 RES257 RT RT RT RT RTS RTS RTS RTS RH--20 RH-WOP RH-2-5 RH-WOP RTMM RTMM RTMM RTMM High Limit Control HLC-65 Check Valve RV-M SL SL SL SL SL SL SL08XX-200 SL02XX-200 SL07XX-200 SL408XX-200 SL402XX-200 SL407XX-200 RESL08-00 RESL02-00 RESL07-00 RESL RESL RESL RTL RTL RTL RTL RTL RTL RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RTCL-00 RHL-WOP RHL-2-5 RHL-WOP RHL-WOP RHL-2-20 RHL-WOP TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK7 FK7 FK7 FK7 FK7 FK7 CHART 2 Heaters with Thermostats Temperature Range ON 80 F (27C) 00 F (8C) 20 F (49C) OFF 00 F (8C) 20 F (49C) 40 F (C) Sensing Unit FSU8 FSU0 FSU2 S Model with thermostat assembly Replacement Tank Replacement Element High Limit Control Adjustable 90-0 F (2-54 C) Example: FSU90-0 Model Number: S T-Stat Replacement: FSU0 Temperature Sensing Unit Mounting rackets Element O-Ring Replacement ox ADAPTER FITTINGS For the use of 0.75 or ID heater hose, hose barb adapters are available. See below. Check Valve Replacement Tank Replacement Element High Limit Control H- NPT to hose barb adapter. Installs in NPT female inlet or outlet of the heater. Temperature Sensing Unit Mounting rackets Element O-Ring Replacement ox H-/4 NPT to 0.75 hose barb adapter. Installs in NPT female inlet or outlet of the heater. Check Valve SL Model with thermostat assembly Customer Service: hotstart.com

12 Thermosiphon Engine Heaters Engine Displacement Model Number without Thermostat Model Number with Thermostat see chart Volts Watts Phase Amps WL Series Weathertight Three Phase 0-800cid L WL WL WL25A WL WL WL258XX-200 WL252XX-200 WL25AXX-200 WL254XX-200 WL255XX Watts cid L WL WL WL40A WL WL WL408XX-200 WL402XX-200 WL40AXX-200 WL404XX-200 WL405XX cid L WL WL WL50A WL WL WL508XX-200 WL502XX-200 WL50AXX-200 WL504XX-200 WL505XX CHART WL Model without thermostat Heaters with Thermostats To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temp. Range: F Model Number: WL252XX-200 Order as: WL Temperature Range ON 80 F (27C) 00 F (8C) 20 F (49C) OFF 00 F (8C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Numerical Code A All phase heaters with thermostat must use a control box. See Control Systems page 0. WL Model with thermostat WL Model mm OUTLET, NPT ADJUSTALE FEMALE 5.25 mm mm INLET, NPT FEMALE mm ADJUSTALE OUTLET, NPT FEMALE mm mm INLET, NPT FEMALE 2 Customer Service: hotstart.com

13 Model Number without Thermostat Model Number with Thermostat see chart 2 Element Replacement Common Replacement Parts available for all listed heaters Replacement Parts WL WL WL25A WL WL WL WL WL40A WL WL WL WL WL50A WL WL WL258XX-200 WL252XX-200 WL25AXX-200 WL254XX-200 WL255XX-200 WL408XX-200 WL402XX-200 WL40AXX-200 WL404XX-200 WL405XX-200 WL508XX-200 WL502XX-200 WL50AXX-200 WL504XX-200 WL505XX-200 REWL258 REWL252 REWL25A REWL254 REWL255 REWL408 REWL402 REWL40A REWL404 REWL405 REWL508 REWL502 REWL50A REWL504 REWL505 Tank Element O-ring High Limit Control Mounting rackets Check Valve RTL TML-OR HLC-65 FK7 RV-M For thermosiphon engine heaters WL Series CHART 2 Heaters with Thermostats Temperature Range ON 80 F (27C) 00 F (8C) 20 F (49C) OFF 00 F (8C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Sensing Unit FSU8 FSU0 FSU2 FSU90-0 Example: Model Number: WL T-Stat Replacement: FSU0 WL Model with thermostat assembly High Limit Control Replacement Thermostat Mounting rackets Replacement Tank Replacement Element Element O-Ring ADAPTER FITTINGS For the use of 0.75 or ID heater hose, hose barb adapters are available. See below. H- H-/4 NPT to hose barb adapter. Installs in NPT female inlet or outlet of the heater. NPT to 0.75 hose barb adapter. Installs in NPT female inlet or outlet of the heater. Check Valve Customer Service: hotstart.com

14 Thermosiphon Engine Heaters Engine Displacement Model Number without Thermostat Model Number with Thermostat Volt Watt Phase Amp EE Series Hazardous Location Single Phase 500cid or less 8.2L or less EE EE EE EE EE EE EE EE EE EE Watts 500-0cid L EE-000 EE EE EE-000 EE EE EE EE0-000 EE EE EE EE cid L EE EE EE EE EE EE EE EE EE EE EE Model without thermostat cid L EE EE EE EE EE EE EE EE EE EE cid L EE EE EE EE EE EE EE EE404XX cid L EE EE EE EE EE EE EE Model assembled with thermostat Heaters with Thermostats EE Models are only available with a fixed setting temperature sensor. Temperature Range ON OFF Numerical Code 00 F (8C) 20 F (49C) 0 All heaters over V with a thermostat must use a control box. See Control Systems page 0. EE Model mm ADJUSTALE OUTLET, NPT FEMALE 5. 5mm 5. 5mm INLET, NPT FEMALE mm ADJUSTALE OUTLET, NPT FEMALE mm 5. 5mm 4 Customer Service: hotstart.com

15 Model Number without Thermostat Model Number with Thermostat Element Replacement Common Replacement Parts available for all listed heaters Replacement Parts EE EE EE EE EE EE EE EE EE EE REEE5 REEE58 REEE52 REEE57 E054E-50NA-00 Tank Flange RTL RF-L For thermosiphon engine heaters EE Series EE-000 EE EE EE-000 EE EE EE EE EE EE EE EE EE0-000 EE EE EE EE EE EE EE EE EE REEE20 REEE REEE202 E020E-50NA-00 E0204E-50NA-00 E0205E-50NA-00 REEE258 REEE252 REEE257 E025E-C0NA-00 E0254E-C0NA-00 Flange O-ring Mounting rackets Check Valve TML-OR FK7 RV-M Heaters with Thermostats Temperature Range ON OFF Sensing Unit 00 F (8C) 20 F (49C) RSU0 Example: EE EE EE EE EE EE EE EE EE EE REEE08 REEE02 REEE07 E004E-50NA-00 E005E-50NA-00 Model Number: EE T-Stat Replacement: RSU0 EE EE EE EE EE EE EE EE REEE408 REEE402 REEE407 E0404E-50NA-00 EE EE EE EE EE EE E0507E-C0NA-00 E0504E-C0NA-00 E0505E-C0NA-00 EE Model with thermostat assembly Flange & O-Ring Replacement Element ADAPTER FITTINGS Replacement Tank Mounting rackets For the use of 0.75 or ID heater hose, hose barb adapters are available. See below. Check Valve H- NPT to hose barb adapter. Installs in NPT female inlet or outlet of the heater. Replacement Thermostat MC-HL Cable H-/4 NPT to 0.75 hose barb adapter. Installs in NPT female inlet or outlet of the heater. Customer Service: hotstart.com 5

16 Thermosiphon Engine Heaters Engine Displacement Model Number without Thermostat Model Number with Thermostat Volt Watts Phase Amp EE Series Hazardous Location Three Phase 500cid or less 8.2L or less EE EE EE EE EE EE Watts 500-0cid L EE EE EE-000 EE EE EE0-000 EE EE EE EE cid L EE EE EE EE EE EE EE EE EE EE EE Model without thermostat cid L EE EE EE EE EE EE EE EE EE EE cid L EE EE EE EE EE EE EE EE EE EE EE Model assembled with thermostat cid L EE EE EE EE EE EE EE EE EE EE Heaters with Thermostats EE Models are only available with a fixed setting temperature sensor. Temperature Range ON OFF Numerical Code 00 F (8C) 20 F (49C) 0 All phase heaters with thermostat must use a control box. See Control Systems page 0. EE Model mm ADJUSTALE OUTLET, NPT FEMALE 5. 5mm 5. 5mm INLET, NPT FEMALE mm ADJUSTALE OUTLET, NPT FEMALE mm 5. 5mm 6 Customer Service: hotstart.com

17 Model Number without Thermostat Model Number with Thermostat Element Replacement Common Replacement Parts available for all listed heaters Replacement Parts EE EE EE EE58XX-000 EE52XX-000 EE54XX-000 E058E-5NA-00 E052E-5NA-00 E054E-5NA-00 Tank Flange RTL RF-L For thermosiphon engine heaters EE Series EE EE EE-000 EE EE EEXX-000 EE202XX-000 EE20XX-000 EE204XX-000 EE205XX-000 E0E-25NA-00 E0202E-25NA-00 E020E-25NA-00 E0204E-25NA-00 E0205E-25NA-00 Flange O-ring Mounting rackets TML-OR FK7 Heaters with Thermostats EE EE EE EE EE EE258XX-000 EE252XX-000 EE25XX-000 EE254XX-000 EE255XX-000 E0258E-0NA-00 E0252E-0NA-00 E025E-0NA-00 E0254E-0NA-00 E0255E-0NA-00 Check Valve RV-M Temperature Range ON OFF Sensing Unit 00 F (8C) 20 F (49C) RSU0 EE EE EE EE EE EE08XX-000 EE02XX-000 EE0XX-000 EE04XX-000 EE05XX-000 E008E-0NA-00 E002E-0NA-00 E00E-0NA-00 E004E-0NA-00 E005E-0NA-00 Example: Model Number: EE T-Stat Replacement: RSU0 EE EE EE EE EE EE408XX-000 EE402XX-000 EE40XX-000 EE404XX-000 EE405XX-000 E0408E-50NA-00 E0402E-50NA-00 E040E-50NA-00 E0404E-50NA-00 E0405E-50NA-00 EE EE EE EE EE EE508XX-000 EE502XX-000 EE50XX-000 EE504XX-000 EE505XX-000 E0508E-50NA-00 E0502E-50NA-00 E050E-50NA-00 E0504E-50NA-00 E0505E-50NA-00 EE Model with thermostat assembly Flange & O-Ring Replacement Element ADAPTER FITTINGS For the use of 0.75 or ID heater hose, hose barb adapters are available. See below. Replacement Tank Mounting rackets H- NPT to hose barb adapter. Installs in NPT female inlet or outlet of the heater. Check Valve H-/4 NPT to 0.75 hose barb adapter. Installs in NPT female inlet or outlet of the heater. Replacement Thermostat MC-HL Cable Customer Service: hotstart.com 7

18 Installation Instructions for Thermosiphon Engine Heaters The HOTSTART engine heater uses thermosiphon action the natural expansion and rising action of a heated fluid to circulate heated coolant throughout an engine s water jacket. Installation of the heating system is critical. Please refer to specific instructions that accompany your HOTSTART engine heater or visit hotstart.com and select Installation Instructions, Manuals and Guides from the Resources tab. For V engines larger than eight cylinders or over 000 CID (5L), HOTSTART recommends using a HOTflow heater. Please refer to pages 4-5 for heater selection. Prior to heater installation, inspect the coolant supply. When mixing coolant, only use deionized or distilled water and low-silicate antifreeze. Refer to your engine s manufacturer recommendations. Do not exceed % antifreeze to 40% water ratio. Never add unmixed water and antifreeze to an engine. Do not add anti-leak or other coolant additives. PREPARING Drain and flush cooling system to remove any debris present in the engine s cooling system. Select return port. The return port will allow heated coolant to return to the engine. Select supply port. The supply port will allow coolant to flow from the engine to the heater. Select fittings. Use the following table to determine the proper port fitting size for your heater: C/CL/S/SL watts /2 inch NPT C/CL/S/SL watts /4 inch NPT WL/EE watts /4 inch NPT Select hoses. Use the following table to determine the minimum hose inner diameter for your heater: C/CL/S/SL watts /4 inch NPT C/CL/S/SL watts inch NPT WL/EE watts inch NPT HOTSTART recommends installing valves to isolate the heating system in case of service. To minimize flow restriction, select full-flow ball isolation valves. MOUNTING Select a heater mounting position directly below the return port and at least 6 inches (5 cm) below the lowest point of the engine s water jacket. Mount heater using the supplied mounting brackets and fasteners. PLUMING Install isolation valves to port fittings. Route and install return hose. The return hose should continuously rise from the heater to the return port. Route and install supply hose. The supply hose should continuously descend from the supply port to the heater. Refill cooling system with coolant. To prevent air pockets, refill coolant with return hose removed. Start engine. Allow engine to run until engine thermostat opens, purging air from cooling system. Engine must be run to eliminate air from heating system before energizing heater. WIRING Connect heater to an appropriately rated power source. Ensure power source is grounded and in accordance with local and national electrical codes. If necessary, install control box: If your heater is single-phase and rated up to volts, your heater may be powered directly without the use of a control relay or contactor. If your heater is three-phase or is single-phase and rated for over volts, the heater thermostats must be used in a control circuit with a contactor for switching the main power to the heating elements. RETURN PORT Select a return port away from the engine thermostat. Select a return port high on the engine. Select a return port toward the rear of the engine. Select a return port away from the remote thermostat. NOTE: If an optional remote thermostat is installed Select a return port away from the supply port. SUPPLY PORT Select a supply port low on the engine. Select a supply port toward the front of the engine. Select a supply port away from the return port. HEATER MOUNTING Mount the heater in the proper orientation. Ensure heater outlet faces upward. Mount the heater to a vibration-isolated surface. Mount the heater directly below the return port. Mount the heater at least 6 inches (5 cm) below the lowest point of the water jacket. 8 Customer Service: hotstart.com

19 SECTION 2 LUE OIL AND INDUSTRIAL IMMERSION HEATERS

20 Oil Heaters Oil Heaters up to 277 V AC meet recognized CSA standards for safety or performance. Use a thermostat with all lube oil heaters to protect the oil from overheating. Lube oil heaters must always be installed in the sump with the entire heater submerged below the oil level at all times. See page 2 for remote thermostat part numbers. *NOTE: If heating gear oil (medium weight viscosity), HOTSTART recommends using low watt density heaters Oil Capacity Weathertight Heater Only Weathertight With Thermostat Hazardous Location Heater Only Volts Watts Amps Watts/Sq Inch To specify temperature range of thermostat, insert code from chart in place of the XX in model number. Example: Desired Temp. Range F Model Number: OW22XX-000 Order as: OW2-000 Temperature Range ON F (6C) 80 F (27C) 00 F (8C) OFF 80 F (27C) 00 F (8C) 20 F (49C) Code See p.2 for remote thermostat assembly part numbers. 2 qt. (2L) or Less 2-6 qt L - 5 gal..8-9l 5-5 gal. 9-57L - 5 gal..8-9l 5-5 gal. 9-57L /8 N.P.T. THREAD WITH A 2 /8 (54mm) PROE LENGTH OW OW /2 N.P.T. THREAD WITH A 4 (0mm) PROE LENGTH OW OW OW22XX-000 OW222XX-000 OE OE /4 N.P.T. THREAD WITH A 5 (27mm) PROE LENGTH OW OW OW OW OW OW45XX-000 OW452XX-000 OW40XX-000 OW408XX-000 OW402XX-000 OE OE OE OE OE N.P.T. THREAD WITH A 5 /4 (mm) PROE LENGTH OW OW OW OW OW OW65XX-000 OW652XX-000 OWXX-000 OW8XX-000 OW2XX-000 OE OE OE OE OE OE OE OE *.6 4.6* *.6 0.7* gal L OW OW OW OW OW650XX-000 OW6508XX-000 OW6502XX-000 OW6507XX-000 OE OE OE OE OE OE OE Oil heater with Y-cord and remote thermostat Weathertight models are furnished with a 4 (.2m) oil and heat resistant power cord without plug. Hazardous Location models are furnished with 8 (457mm) of lead wire for connection to the power leads in an approved splice box. DC Oil Heaters 2 V and 24 V When used with a thermostat control, all DC oil heaters must use a DC relay. _ 2 or 24 V DC + DIT C COIL Magnetic Contactors C 2 Vdc/24 Vdc CONTROL OXES C Oil Heater Oil Capacity 2 qt. 2.0L or Less 2-6 qt L -5 gal..8-9l 5-5 gal. 9-57L 5-0 gal. 57-L /2 NPT with Volts Watts 4 (0mm) Probe Length OW /4 NPT with 4 7/8 (24mm) Probe Length OW OW NPT with 5 /8 (6mm) Probe Length Amps 6.. Watts Per Square Inch /2 4.7* WSI /4 7.* WSI OW WSI OW OW OW OW OW OW OW /4 4.6* WSI 0.7* WSI /4 29. WSI 2.4 WSI OW WSI 25 Amps Maximum 2V 24V JMC0DC-2V JMC0DC-24V 2 V DC and 24 V DC oil heaters can be powered directly from the battery, but will drain the battery very rapidly unless charged by an alternator or generator. 20 Customer Service: hotstart.com

21 Weathertight Heater only Hazardous Location Heater only mm 5.25 mm Probe Length.00 NPT.00 Dia. 25mm mm 5.25 mm Probe Length.00 NPT.00 Dia. 25.5mm mm mm Probe Length /4 NPT mm mm mm Probe Length /4 NPT mm mm mm Probe Length /2 NPT 0.50 Dia. mm 8.0 2mm mm Probe Length /2 NPT 0.50 Dia. mm REMOTE THERMOSTATS for OIL HEATERS Switch Capacity Weathertight DIT68 DIT80 DIT02 DIT24 Hazardous Location DIT68EP DIT80EP DIT02EP DIT24EP Temprature Range ON OFF F (6C) 80 F (27C) 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Sensing Unit LSU-6 LSU-8 LSU-0 LSU-2 Thread Size /2 NPT /2 NPT /2 NPT /2 NPT 20 V - 5amp V - 0amp V - 0amp 277 V - 0amp 2 V DC 24 V DC } Pilot Duty Only (m) 6- HPN cord.75 86mm /2 NPT.625 4mm Probe Length 0. Dia. 5mm.25 8mm mm /2 NPT.625 4mm Probe Length 0. Dia. 5mm Weathertight Hazardous Location Customer Service: hotstart.com 2

22 Industrial Immersion Heaters 2 Screw Plug Available with fixed or adjustable thermostat. Models for larger capacities than shown are available. Call factory. Oil Capacity HIGH LIMIT THERMOSTAT CONTROL SETTING On F (6C) Off 80 F (27C) On 80 F (27C) Off 00 F (8C) On 00 F (8C) Off 20 F (49C) SINGLE PHASE 2 N.P.T. WITH A 2 (05mm) PROE LENGTH Volts Watts Amps Watts/ Sq. In Gallons -70L E00W-56A-00 E008W-56A-00 E002W-56A-00 E007W-56A-00 E00W-58A-00 E008W-58A-00 E002W-58A-00 E007W-58A-00 E00W-5A-00 E008W-5A-00 E002W-5A-00 E007W-5A C US 45 - Gallons L E05W-56A-00 E058W-56A-00 E052W-56A-00 E057W-56A-00 E05W-58A-00 E058W-58A-00 E052W-58A-00 E057W-58A-00 E05W-5A-00 E058W-5A-00 E052W-5A-00 E057W-5A THREE PHASE 2 N.P.T. WITH A 2 (05mm) PROE LENGTH Weathertight Model NEMA Gallons -70L E008W-06A-00 E002W-06A-00 E00W-06A-00 E004W-06A-00 E008W-08A-00 E002W-08A-00 E00W-08A-00 E004W-08A-00 E008W-0A-00 E002W-0A-00 E00W-0A-00 E004W-0A Gallons L E058W-56A-00 E052W-56A-00 E05W-56A-00 E054W-56A-00 E058W-58A-00 E052W-58A-00 E05W-58A-00 E054W-58A-00 E058W-5A-00 E052W-5A-00 E05W-5A-00 E054W-5A C US SINGLE PHASE 2 N.P.T. WITH A 8 (457mm) PROE LENGTH (LVD only) Hazardous Location Model NEMA 4 & 7-90 Gallons 227-4L E020W-56A-00 E0W-56A-00 E0202W-56A-00 E0207W-56A-00 E020W-56A-00 E0204W-56A-00 E020W-58A-00 E0W-58A-00 E0202W-58A-00 E0207W-58A-00 E020W-58A-00 E0204W-58A-00 E020W-5A-00 E0W-5A-00 E0202W-5A-00 E0207W-5A-00 E020W-5A-00 E0204W-5A THREE PHASE 2 N.P.T. WITH A 8 (457mm) PROE LENGTH - 90 Gallons 227-4L E0W-56A-00 E0202W-56A-00 E020W-56A-00 E0204W-56A-00 E0W-58A-00 E0202W-58A-00 E020W-58A-00 E0204W-58A-00 E0W-5A-00 E0202W-5A-00 E020W-5A-00 E0204W-5A Hazardous Location models with thermostat also available. Substitute the letter W in part number with the letter E to specify Hazardous Location models. Industrial Immersion Heaters are also available for coolants and other process heating. Call factory. Call HOTSTART for complete model number featuring adjustable thermostat. 22 Customer Service: hotstart.com

23 HOTSTART immersion heaters include a fixed-setting, built-in thermostat and are available with an adjustable thermostat. Weathertight Model NEMA 4 Hazardous Location Model NEMA 4 & 7 Industrial Immersion Heaters 2 Screw Plug 4. 09mm 2 or 8 05mm or 457mm mm 2 or 8 05mm or 457mm.6 9mm 4.4 2mm Fixed Thermostat Assembly TEMPERATURE RANGE ON OFF F (6C) 80 F (27C) 00 F (8C) 80 F (27C) 00 F (8C) 20 F (49C) ELECTRICAL RATING 5 Amps at 20 Vac 0 Amps at Vac 0 Amps at 277 Vac Thermostat Sensor Control CONTROL HLC-6 HLC-8 HLC-0 Adjustable Thermostat Assembly Adjustable Thermostat Control TEMPERATURE RANGE OFF 70 F - 20 F (2-99 C) CONTROL AMT70-20 Nominal thermal differential is 8 F (- C) ELECTRICAL RATING 0 Amps at 25 Vac 0 Amps at Vac 0 Amps at 277 Vac 20 Amps at Vac NOTES: On applications where level of fluid is subject to change, a liquid level switch mounted a minimum of -4 (76-02mm) above element is recommended. Liquid level switch is not included with heater. All 80 Volt and Volt heaters must be used in conjunction with contactor and control transformer. All three phase models must be used with a contactor. See page 0. Higher or lower temperature ranges are available. Consult HOTSTART. Customer Service: hotstart.com 2

24 V-Clamp Immersion Heaters Threadless Design Available with fixed or adjustable thermostat. Models for larger capacities than shown are available. Call factory. Oil Capacity HIGH LIMIT THERMOSTAT CONTROL SETTING On F (6C) Off 80 F (27C) On 80 F (27C) Off 00 F (8C) On 00 F (8C) Off 20 F (49C) SINGLE PHASE WITH A 2 (05mm) PROE LENGTH Volts Watts Amps Watts/ Sq. In Gallons -70L E00W-56V-00 E008W-56V-00 E002W-56V-00 E007W-56V-00 E00W-58V-00 E008W-58V-00 E002W-58V-00 E007W-58V-00 E00W-5V-00 E008W-5V-00 E002W-5V-00 E007W-5V C US 45 - Gallons L E05W-56V-00 E058W-56V-00 E052W-56V-00 E057W-56V-00 E05W-58V-00 E058W-58V-00 E052W-58V-00 E057W-58V-00 E05W-5V-00 E058W-5V-00 E052W-5V-00 E057W-5V Weathertight Model NEMA Gallons -70L E008W-06V-00 E002W-06V-00 E00W-06V-00 E004W-06V-00 THREE PHASE WITH A 2 (05mm) PROE LENGTH E008W-08V-00 E002W-08V-00 E00W-08V-00 E004W-08V-00 E008W-0V-00 E002W-0V-00 E00W-0V-00 E004W-0V Gallons L E058W-56V-00 E052W-56V-00 E05W-56V-00 E054W-56V-00 E058W-58V-00 E052W-58V-00 E05W-58V-00 E054W-58V-00 E058W-5V-00 E052W-5V-00 E05W-5V-00 E054W-5V C US SINGLE PHASE WITH A 8 (457mm) PROE LENGTH (LVD only) Hazardous Location Model NEMA 4 & 7-90 Gallons 227-4L E020W-56V-00 E0W-56V-00 E0202W-56V-00 E0207W-56V-00 E020W-56V-00 E0204W-56V-00 E020W-58V-00 E0W-58V-00 E0202W-58V-00 E0207W-58V-00 E020W-58V-00 E0204W-58V-00 E020W-5V-00 E0W-5V-00 E0202W-5V-00 E0207W-5V-00 E020W-5V-00 E0204W-5V THREE PHASE WITH A 8 (457mm) PROE LENGTH - 90 Gallons 227-4L E0W-56V-00 E0202W-56V-00 E020W-56V-00 E0204W-56V-00 E0W-58V-00 E0202W-58V-00 E020W-58V-00 E0204W-58V-00 E0W-5V-00 E0202W-5V-00 E020W-5V-00 E0204W-5V Hazardous Location models with thermostat also available. Substitute the letter W in part number with the letter E to specify Hazardous Location models. Industrial Immersion Heaters are also available for coolants and other process heating. Call factory. Call HOTSTART for complete model number featuring adjustable thermostat. 24 Customer Service: hotstart.com

25 HOTSTART immersion heaters include a fixed-setting, built-in thermostat and are available with an adjustable thermostat. Weathertight Model NEMA 4 Hazardous Location Model NEMA 4 & 7 V-Clamp Immersion Heaters Threadless Design 2 or 8 05mm or 457mm.8 97mm 5. 76mm 2 or 8 05mm or 457mm Element assembly includes O- Ring only. Installation kit sold separately. V-CLAMP INSTALL KIT O-ring Weldable Adapter V-Clamp O-ring Weldable Adapter V-Clamp Part Number VC-SK Parts Included Steel weldable adapter V-Clamp O-ring.6 9mm 4.4 2mm Fixed Thermostat Assembly TEMPERATURE RANGE ON OFF F (6C) 80 F (27C) 00 F (8C) 80 F (27C) 00 F (8C) 20 F (49C) ELECTRICAL RATING 5 Amps at 20 Vac 0 Amps at Vac 0 Amps at 277 Vac Thermostat Sensor Control CONTROL HLC-6 HLC-8 HLC-0 Adjustable Thermostat Assembly Adjustable Thermostat Control TEMPERATURE RANGE OFF 70 F - 20 F (2-99 C) CONTROL AMT70-20 Nominal thermal differential is 8 F (- C) ELECTRICAL RATING 0 Amps at 25 Vac 0 Amps at Vac 0 Amps at 277 Vac 20 Amps at Vac NOTES: On applications where level of fluid is subject to change, a liquid level switch mounted a minimum of -4 (76-02mm) above element is recommended. Liquid level switch is not included with heater. All 80 Volt and Volt heaters must be used in conjunction with contactor and control transformer. All three phase heaters must be used with a contactor. See page 0. Higher or lower temperature ranges are available. Consult HOTSTART. Customer Service: hotstart.com 25

26 SECTION TEMPERATURE CONTROLS and CONTROL SYSTEMS

27 Temperature Controls Remote Thermostats for Weathertight and Hazardous Location Oil Heaters (see p.20 for model numbers) REMOTE THERMOSTATS for OIL HEATERS Switch Capacity Weathertight DIT68 DIT80 DIT02 DIT24 Hazardous Location DIT68EP DIT80EP DIT02EP DIT24EP Temprature Range ON OFF F (6C) 80 F (27C) 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Sensing Unit LSU-6 LSU-8 LSU-0 LSU-2 Thread Size /2 NPT /2 NPT /2 NPT /2 NPT 20 V - 5amp V - 0amp V - 0amp 277 V - 0amp 2 V DC 24 V DC } Pilot Duty Only.75 86mm.625 4mm Probe Length 0. Dia. 5mm.25 8mm mm.625 4mm Probe Length 0. Dia. 5mm (m) 6- HPN cord /2 NPT /2 NPT Weathertight Hazardous Location Remote Adjustable Thermostat for TPS Thermosiphon Engine Heater (see p.7 for model numbers) 5/8 H x 5/8 H mm 4- HPN 4 (.2m) Part Number Adjustable Range Temperature Setting Sensing Unit TFTA-5/8H Adjustable 90-0 F (2-54 C) FSU mm mm Part number does not include Y cord Power Y-cord OUTLET HOSEAR I.D HOSEAR Adjustable Thermostat Assembly mm mm In-Line Adjustable Thermostat INLET HOSEAR I.D. Customer Support: hotstart.com 27

28 Temperature Controls When using a thermostat above rated capacity or on phase applications, select the proper control box with transformer and contactor as shown on page 0. NPT female x NPT male CONDUIT TYPE ENCLOSURE Part Number TFTC8-200 TFTC0-200 TFTC2-200 TFTCA-200 Temperature Setting On Off 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Maximum Capacity Ratings 20/ V 277V V 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp NPT male x NPT male CONDUIT TYPE ENCLOSURE Part Number TFTC8-220 TFTC0-220 TFTC2-220 TFTCA-220 Temperature Setting On Off 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Maximum Capacity Ratings 20/ V 277V V 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp hose barb x NPT male CONDUIT TYPE ENCLOSURE Part Number TFTC8- TFTC0- TFTC2- TFTCA- Temperature Setting On Off 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Maximum Capacity Ratings 20/ V 277V V 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp.0 76mm mm /2" NPT Conduit Opening Part Number HAZARDOUS LOCATION CONDUIT TYPE ENCLOSURE Temperature Setting On Off Maximum Capacity Ratings 20/ 277V V V.0 " NPT Inlet TFT0ER 00 F (8C) 20 F (49C) 25amp 22amp 22amp.25 2mm mm 28 Customer Service: hotstart.com

29 When using a thermostat above rated capacity or on phase applications, select the proper control box with transformer and contactor as shown on page 0. Temperature Controls NPT female x NPT male CORD CONNECTED Part Number TFT8-200 TFT0-200 TFT2-200 TFTA-200 Temperature Setting On Off 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Maximum Capacity Ratings 20/ V 277V V 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp NPT male x NPT male CORD CONNECTED Part Number TFT8-220 TFT0-220 TFT2-220 TFTA-220 Temperature Setting On Off 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Maximum Capacity Ratings 20/ V 277V V 25amp 22amp 25amp 22amp 25amp 22amp 22amp 22amp 22amp 25amp 22amp 22amp hose barb x NPT male CORD CONNECTED Part Number TFT8- TFT0- TFT2- TFTA- Temperature Setting On Off 80 F (27C) 00 F (8C) 00 F (8C) 20 F (49C) 20 F (49C) 40 F (C) Adjustable 90-0 F (2-54 C) Maximum Capacity Ratings 20/ V 277V V 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp 25amp 22amp 22amp Part Number REMOTE ADJUSTALE With 5 (.5m) Capillary Probe Adjustable Range Temperature Setting Maximum Capacity Ratings 20// V 277V V.0 76mm.9 48mm.4 86mm AT F (8-2 C) (Open or Off Setting) Differential 7 F (-4 C) (Close or On Setting) 25amp 22amp 5amp 6.4 6mm mm LO mm Dia. ATW Aluminum Well for AT6525 /2 NPT Customer Service: hotstart.com 29

30 Control Systems Control systems allow for quick electrical installation of all HOTSTART engine heaters. They are designed as a time and labor saving component. Control systems are especially useful on installations that require two coolant heaters or combinations of a coolant heater and oil heater/hydraulic heater etc. All control boxes on this page are NEMA 4, 2 & IP66. CONTROL SYSTEMS CONTROL SYSTEMS featuring AUTOMATIC SHUTDOWN DEVICES With 24 V DC Relay Amps Volts Heater, Thermostat per application 2 Heaters, 2 Thermostats per application 0A Max 0A Max 0A Max 0A Max 0A Max 0A Max JC-00 JC8-00 JC2-00 JCA-00 JC4-00 JC5-00 JC2-00 JC28-00 JC22-00 JC2A-00 JC24-00 JC25-00 Model JC4-00 See wiring schematic page Model JC24-00 See wiring schematic page All HOTSTART heaters with thermostat, operating on three phase current (at any voltage), require the use of a control system with a -pole contactor. All HOTSTART heaters with thermostat, operating over V (single or three phase) require a control system to reduce the primary voltage to 20 V for the control circuit. For increased thermostat life, use a control system on all heaters above 277 V either single or three phase. All control boxes can be used with either single or three phase heaters. Control boxes are available in Hazardous Location models - contact factory for part number. For heater protection and power savings, HOTSTART recommends de-energizing the heater when engine is running. Control boxes are supplied with a 24 V relay to de-energize the heater upon engine start-up. 0 Customer Service: hotstart.com

31 Wiring Schematic for JC4-00 USER SUPPLIED CIRCUIT REAKER L MAIN L2 POWER IN L Control Systems EQUIPMENT GROUND MUST E GROUNDED H4 CONTROL TRANSFORMER V PRIMARY C H MAGNETIC CONTACTORS K X 20V 50VA X2 C2 HEATING ELEMENT A USER SUPPLIED 24VDC SIGNAL A2 K2 2 N/C Model JC4-00 CONTACTOR COIL K 4 2 USER SUPPLIED THERMOSTAT To control one V heater at maximum 0 amps on manual start engine. Wiring Schematic for JC24-00 MAIN POWER IN USER SUPPLIED CIRCUIT REAKER L L2 L EQUIPMENT GROUND MUST E GROUNDED H4 X CONTROL TRANSFORMER V PRIMARY 20V 50VA C H X2 MAGNETIC CONTACTORS C2 K C K2 A USER SUPPLIED 24VDC SIGNAL A2 C4 K 2 N/C HEATING ELEMENT HEATING ELEMENT Model JC24-00 CONTACTOR COIL 4 K 2 5 K2 2 USER SUPPLIED THERMOSTAT CONTACTOR COIL To control two V heaters at maximum 0 amps on automatic start engines. Customer Service: hotstart.com

32 Power Distribution ox POWER DISTRIUTION OX Use to simplify wiring on equipment when a variety of heaters and controls are required. All models have ten, 25 Amp terminal blocks. Power Distribution oxes are rated NEMA 4 and IP66/67 PD-000 Part Number Number of Openings *ox comes assembled with 4 strain relief connectors. For additional connectors, order part# A PD-000 8* 4.5 4mm.0 76mm 0 AMP MAX A mm OIL PRESSURE SWITCH For automatic cut-off of heaters when engine starts. Maximum Current Capacity: 20 V/ V/ V/277 V 25 Amps 80 V/ V/575 V 5 Amps Two pole single throw To prevent overheating of the heating element on standby equipment and automatic start engines, HOTSTART recommends turning the coolant heater off when the engine is running. A pressure switch that senses engine oil pressure is utilized to shut the heater off on increase of oil pressure and to turn the heater on when engine oil pressure drops. Part Number Enclosure Type NEMA PS252 PS252R PS252WT PS252EP Dry Locations Dry Locations (Reverse Action) Wet Locations Hazardous Locations 2 Customer Service: hotstart.com

33 SECTION 4 ATTERY PADS/WRAPS

34 attery Heating Pads Model Number Volts Watts Amps Nominal Dimensions A attery Size Style K505 K505-S K505-D (24mm) 2.75 (24mm) 2.75 (24mm) 8.25 (20mm) 8.25 (20mm) 8.25 (20mm) 4D 4D 4D A C K755 K755-S K755-D (495mm) 9.5 (495mm) 9.5 (495mm) 0.5 (267mm) 0.5 (267mm) 0.5 (267mm) 8D 8D 8D A C attery heater not recommended for nickel cadmium batteries. When batteries are placed in an insulated battery box, a thermostat is recommended to sense battery box temperature to prevent overheating the battery. Standard Pad for Single attery K752 K752-S K752-D Typical Connection - 2 atteries on Each Side of Vehicle Left Side attery ox K755-D K755-D (495mm) 9.5 (495mm) 9.5 (495mm) Right Side attery ox K755-D 0.5 (267mm) 0.5 (267mm) 0.5 (267mm) K755-S 8D 8D 8D A C A Style A EC-6 Ground Y-T68 PC-6 6 HPN.8m Accessories For Multiple attery Heating Special Pads for Multiple atteries mm 6- HPN mm Style Style C 6- HPN A A Part Number EC-2 EC-4 EC-6 EC-8 EXTENSION CORDS 2 (0.7m) 4 (.2m) 6 (.8m) 8 (2.4m) Length 2 (0.7m) 4 (.2m) 6 (.8m) 8 (2.4m) POWER SUPPLY CORDS Part Number Length Volts PC- (m) 20 PC-2 (m) PC-6 6 (.8m) 20 PC-62 6 (.8m) (m) 6 (.8m) 6- HPN THERMOSTAT & Y CORD ASSEMLY Part Number Temperature Control On Off Y-T68 F (6 C) 80 F (27 C).2 5mm CORD 6- HPN.5 4mm mm 4 Customer Service: hotstart.com

35 ATTERY THERMAL WRAP NO THERMOSTAT Model Number Volts Watts Length attery Thermal Wrap KW (7mm) KW (94mm) KW (829mm) Prolong the life of your battery with HOTSTART thermal battery wraps with or without thermostat. Durable, fire-retardant vinyl cover that resists oils and acids. All standard battery pads and battery wraps come with 6 (.8m) grounded cord and plug. Fast, easy installation. oosts battery cranking power as much as 75%. ATTERY THERMAL WRAP WITH THERMOSTAT Thermostat range: 65 F - 80 F (8 C - 27 C) Model Number Volts Watts Length KW505T-000 KW5024T (7mm) 28 (7mm) KW805T-000 KW8024T (8mm) 44 (8mm) KW005T-000 KW0024T (422mm) 56 (422mm) Thermostatically controlled battery thermal wraps provide optimum heating regardless of ambient temperature. At 80 F (27 C), the battery will achieve maximum cold cranking amps. attery is constantly maintained at 80 F (27 C). Provides greater heat rise than plates or pads. Thermostat will eliminate battery damage caused by overheating and acid spill. Customer Service: hotstart.com 5

36 Silicone Pad Heaters Versatile and Easy to Install HOTSTART adhesive pad heaters can be used on oil pans, hydraulic reservoirs, engine blocks, hydraulic cylinders and diesel fuel tanks. Easy peel and stick application. Etched foil heating element for optimal heat transfer and long life. Durable silicone/fiberglass cover resists abrasion. 20 V models are assembled with a standard 6 (.8m) HPN cord and plug. V models include 6 (.8m) HPN cord without plug. Model Number Dimensions Volts Watts Not for use on batteries AF005 AF x 5 (02mm x 27mm) AF505 AF x 5 (02mm x 27mm)) AF2505 AF x 6 (27mm x 52mm) AF4005 AF x 8 (52mm x 20mm) Application Guidline 00 Watt 50 Watt 250 Watt 400 Watt Engine oil pan 2-5 quarts.9-4.7l 5-8 quarts L 2-5 gallons L 5-8 gallons L Diesel Tank 5-7 gallons L 7-0 gallons L 0-20 gallons L 20-0 gallons L Hydraulic Tank - 5 gallons L 5-0 gallons L 0-20 gallons L 20-0 gallons L Water Tank up - 2 gallons up - 7.5L 2-4 gallons L 4-7 gallons L 7-0 gallons L CAUTION: Do not use pads with higher than recommended wattage for specific oil capacities. For use on metal surfaces only. 6 Customer Service: hotstart.com

37 SECTION 5 IN-LOCK HEATERS and ACCESSORIES 7

38 In-block Heaters In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required 670T & I 685T & I 68LT, T & I (844 CID) AC-0 CATV-5 AC-02 CATV Allis Chalmers Replaces thread-in plug on the oil cooler at rear of the engine on right side. Not all of the engines have this opening. Case/IH Agricultural ALL 4 CYL 90 ALL 6 CYL 590 CU-75FP CU-0FP CU-5FP CU-752FP CU-02FP CU-52FP Inserts in any of the core plugs on right side of engine. ALL 6 CYL 80 CUC-5FP CUC-52FP 500 Inserts in the core plug at right rear of engine block. Caterpillar C-0 C-2 TF2-000 TF Replaces the threaded plug in the oil cooler bonnet on the right side of engine. YES C-9 Non ACERT C-5 Non ACERT C-6 Non ACERT CATV-5 CATV C-9: Replaces NPT plug in the right rear of engine block. C-5, C-6: Replaces the threaded plug in the back of the oil cooler. C7 ACERT 26 FP0-00 FP5-00 FP02-00 FP Replaces the 44mm core plug on right side of engine just below the turbo charger. YES C7 ACERT rear port TL0-000 TL Replaces the threaded -/6 (.0625 ) plug in the rear of engine block. C9 ACERT CATV-5 CATV Replace NPT plug in the right rear of engine block. C ACERT C ACERT TF5-008 TF Replace any -5/6 (.25 ) plug in the rear of the oil cooler on right side of engine. Check Exhaust Routing C5 ACERT w/o breaksaver TF5-009 TF Replace -/6 (.875 ) plug in rear of oil cooler on right side of engine. C5 ACERT with breaksaver TF5-008 TF Replace any -5/6 (.25 ) plug in the oil cooler on right side of engine. C ACERT C 2007 ACERT C ACERT TF5-02 TF Replace any -/6 (.875 ) plug in rear of oil cooler on right side of engine. 674 CAT-5 CAT Replace the -/2 (.5 ) plug on right side of engine. 69 & D4 CATC-5 CATC Replaces the water jacket access plate on left side of engine. 69T & 69TA CATC-5-S CATC-52-S 500 Replaces the water jacket access plate on left side of engine. 0.5L L FP5-00 FP Replaces 40mm core plug on the front left side of engine. 8 Customer Service: hotstart.com

39 In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. In-block Heaters C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required Caterpillar Continued L FP5-00 FP Replaces 40mm core plug on the front left side of the engine L FP5-00 FP Replaces 50mm core plug located at rear of head. 044.L PF5-00 PF Replaces the plate in oil cooler case on left side of engine L PF5-000 PF Replaces 5mm core plug located at rear of engine, left side L L PER-75FP PER-0FP PER-752FP PER-02FP Mounts in the -/4 (.25 ) core plug opening on left side of engine. 054C PER-75FP PER-752FP 750 Mounts in -/4 (.25 ) core plug at right rear of engine with element oriented in the 2 O clock position L PER-5FP PER-52FP 500 Mounts in the -/2 (.5 ) core plug on right side of engine. 4 6 FP0-00 FP5-00 FP02-00 FP Replaces the 44mm core plug on right side of engine just below the turbocharger. YES 76 0.L through 995 DD8L-0 CAT-205 TF5-00 DD8L-02 CAT-202 TF Replaces the /4 (0.75 ) threaded plug on the right side of engine just below the head L 996 and later TF2-000 TF Replaces the threaded plug in the oil cooler bonnet on right side of engine. YES L TF2-000 TF Replaces the threaded plug in oil cooler bonnet on right side of engine. YES 204 all 00 series CATX-75 CATX-0 CATX-752 CATX Replaces 44mm core plug on right rear side of engine. 2 heaters with a single cord CATX-2-75-Y CATX Y 500 total Use on industrial engines when clear access is available. Replaces any core plug - one on each side of engine. Recommended aftermarket installation JD/4-0IN JD-0IN JD/4-5IN JD-5IN JD/4-02IN JD-02IN JD/4-52IN JD-52IN Replaces any of the /4 (0.75 ) or plugs on the water transfer casting (right front of engine). /4 use JD/4 use JD DD8L-0 CAT-205 TF5-00 DD8L-02 CAT-202 TF Replaces the /4 (0.75 ) plug on left side of engine. 406C/E 4.6L AC-0 CATV-5 AC-02 CATV Replaces threaded plug in the rear of the oil cooler bonnet on right side of engine. Customer Service: hotstart.com 9

40 In-block Heaters In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required Caterpillar Continued 406 & 408 except 998 ADEM 2 AC-0 CATV-5 AC-02 CATV Replaces threaded plug in the rear of the oil cooler bonnet on right side of engine. 406E 998 ADEM 2 engines only TF5-002 TF Replaces the threaded plug that points downward on the top of the rear of the oil cooler bonnet. YES 406E ADEM and ADEM engines AC-0 CATV-5 AC-02 CATV Replaces threaded plug in the rear of the oil cooler bonnet on right side of engine L AC-0 CATV-5 AC-02 CATV Replaces threaded plug in the rear of the oil cooler bonnet on right side of engine. Cummins 6 Cylinder Engines: H, NT, NH, N Family 74 CID, 855 CID, 927 CID, N4. Cummins engines are often referred to by their horsepower rating i.e. 50 Cummins 2. Cummins engines are often referred to as ig Cam, ig Cam2,, 4, full flow cooling, etc. All refer to engines of 855 CID Size listed below Group I Flat plate design CUN-5 CUN Flat plate design when the /2 NPT opening is used CUN-5H CUN-52H bolt flat plate on the right side of the engine. May use either the forward or rear opening depending on clearance. When an external oil cooler is used.. Group II Note: When a 4 bolt flat plate element design is encountered, remove the next two bolts on the casting, remove the whole casting, and replace the casting and element with either CNT-5/CNT-52 OR CNT590/CNT5290 When connection is /2 rubber hose Engines produced Aug. 975 thru June 982 CNT-5-90 CNT bolt, flat plate design with an elbow that will rotate degrees to connect with any hose or casting. Uses an O ring for the /4 water tube connection Engines produced prior to August 75 CNT-5 CNT bolt, flat plate design with an elbow that will rotate degrees to connect with any hose or casting. Group III For industrial engines with hole pattern reversed CUN-5REV CUN-52REV 500 Six bolt flat plate on the right side of engine block. Group IV 998 and later N4 Industrial PF5-002 PF Six bolt flat plate on the right side of engine block. 40 Customer Service: hotstart.com

41 In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. In-block Heaters C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required Cummins Continued Cummins A 4 cyl & 6 cyl CUA-0F CUA-02F 000 Inserts in any of the core plugs on right side of engine. Element points down. ISC/QSC 8.L ISL/QSL 9.0L DD8L-0 TF DD8L-02 TF Replaces /4 (0.75 ) NPT plug in right front side of engine. L0, M ISM 2007 CUL-5 CUL Inserts in the forward opening of the heater casting on the right rear of engine block. QS.9L, 5.9L IS 5.9 TF TF Replaces /4 (0.75 ) NPT plug in the front of the oil cooler casting. ISM/QSM.0L Flat Plate Design PF5-00 PF Right rear. Replaces plate. ISX, QSX Signature 0 Pre 2007 PF5-004 PF Mounts in the oval shaped plate on the right side of engine block. 4T.9L CU-75FP CU-0FP CU-752FP CU-02FP Replaces 57.8mm core plug on right side of engine. Check Exhaust Routing 6T 5.9L CU-75FP CU-0FP CU-5FP CU-752FP CU-02FP CU-52FP Replaces 57.8mm core plug on right side of engine. Check Exhaust Routing 6CT 8.L CUC-5FP CUC-52FP 500 Replaces 57.8mm core plug on right rear side of engine. Detroit Diesel SERIES 0 4 cylinder Phaser engines PER-75FP PER-0FP PER-752FP PER-02FP Mounts in the -/4 (.25 ) core plug opening on either side of engine. SERIES 0 6 cylinder Phaser engines PER-5FP PER-52FP 500 Mounts in the -/4 (.25 ) core plug on right side of engine. SERIES 0 DD8L-0 TF DD8L-02 TF Mounts in the /4 (0.75 ) NPT opening in engine block. SERIES 40 all versions PER-75FP INTA-2 FR5-00 PER-752FP INTA-22 FR Mounts in the core plug opening on right side of engine. Customer Service: hotstart.com 4

42 In-block Heaters In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required Detroit Diesel continued SERIES 50 SERIES Pre 2007 AC-0 CATV-5 AC-02 CATV Mounts in the NPT opening in either water pick up pipe (up to 99) or in the NPT opening on the oil cooler housing after 99. Yes on 99 and later SERIES 55 PF5-000 PF Mounts in the triangle plate on the side of engine block. -5, 4-5, -7, 4-7 with water cooled air compressor DD-75-S DD-752-S 750 Mounts in the oval shaped plate on engine block. Check clearance. -5, 4-5, -7, 4-7 without water cooled air compressor DD-75 DD Mounts in the oval shaped plate on engine block. Check clearance. 6-7 with water cooled air compressor DD-5-S DD-52-S 500 Mounts in the oval shaped plate on engine block. Check clearance. 6-7 without water cooled air compressor DD-5 DD Mounts in the oval shaped plate on engine block. Check clearance. 8.2 L V-8 Diesel DD8L-0 TF DD8L-02 TF Threads into the /4 (0.75 ) NPT opening on engine block. 6V-5 with water cooled air compressor DD6V-75-S DD6V-752-S 750 Mounts in the oval shaped plate on engine block. Check clearance. 6V-5 without water cooled air compressor DD6V-75 DD6V Mounts in the oval shaped plate on engine block. Check clearance. 6V7 & 8V7 Alternate location AC-0 CATV-5 AC-02 CATV Threads into NPT plug in the front face of engine block. 6V-7 & 8V-7 6V-92 & 8V-92 except GMC General models DDV-5 DDV Mounts in the square plate on engine block. 6V92 & 8V92 alternate location - threads into oil cooler DD8L-0 TF DD8L-02 TF Threads into the /4 (0.75 ) NPT opening in the oil cooler housing. Note - not all engines have this opening. Deutz F4L9 F6L9 FL92 FL9 F6L9 0 SERIES oil cooled engines OLT2255 and A22M48M (adapter) n/a 50 Use adapter kit to mount the 22mm heater in the 48mm opening. 42 Customer Service: hotstart.com

43 In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. In-block Heaters C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required Deutz continued 02 4 & 6 cyl 0 4 cyl PF PF2-00 PF PF Mounts in the oval shaped plate opening on the oil cooler casting. 0 6 cyl PF2-00 PF PF22-00 PF Mounts in the oval shaped plate opening on the top of the oil cooler & 8 cyl TL5-004 TL Replaces 0mm plug in water elbow on front of engine & 6 cyl without electric fuel injection PF PF Replace oval shaped plate on the top of the oil cooler. Ford 7.L V-8 diesels from 994 on TF DD8L-0 TF DD8L Mounts in the /4 (0.75 ) NPT plug in the engine's block. Hino.8L, 5.8L, 6.0L, 6.4L, 6.7L, H06C-T, H07C-, W04C-T, W06E DD8L-0 TF DD8L-02 TF Threads into /4 (0.75 ) NPT opening in engine block. YES Isuzu 4D 6D 6G 6HE 6SA TF40-00 NONE 400 Replaces NPT plug on left rear of engine. Iveco NEF 4cyl NEF 6 cyl PF75-00 PF Mount in front opening on right side of engine block. John Deere With /4 plug in the back of the block JD/4-0IN JD/4-5IN JD/4-02IN JD/4-52IN /4 (0.75 ) NPT opening in the rear face of engine block. Check Exhaust Routing With plug in the back of the block JD-0IN JD-5IN JD-02IN JD-52IN NPT opening in the rear face of engine block. With -5/8 opening on the side of the water jacket JDS-0 JDS-5 JDS-02 JDS /8 (.625 ) threaded opening on the side of the block in the water distribution channel. Customer Service: hotstart.com 4

44 In-block Heaters In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required John Deere continued 5 (0.5L) 625 (2.5L) AC-0 CATV-5 AC-02 CATV NPT opening in the oil cooler casting. Komatsu L0 (0L) M(L) CUL-5 CUL Inserts in the forward opening of the heater casting on the right rear of engine block. SA6D25 MA-5 MA Threads into the core plug opening in engine block., L, M Series D905 V205 D005 V05 D05 V505 D000 V4000 D200 V400 DH905 VH205 DH005 VH05 TF40-00 NONE 400 Kubota Replaces NPT plug on left front of engine. Mack Mid liner E MS200 & MS250 MAM-0 MAM Mounts in rear face of block. Mid liner E5 MS00 MAM-5 MAM Mounts in the oil cooler bonnet. E6 engines smooth bore 98 and later MAS-5 MAS Replaces -/4 (.75 ) core plug on side of engine. E6 engines threaded core plug opening Pre-98 END 465, 7, EN48, 504, 707, 67, 675, 676 (957 through 98) MA-5 MA Mounts in any threaded core plug opening. E7 Engines Except E-Tech water pump mount PF5-00 PF0-000 PF52-00 PF Mounts in the plate in either the front or rear face of the block in the water jacket passage. For 2002 engine mounts in rear face of block. E9, ENDT865, 866 and 000 series V8 engines Use two heaters DD8L-0 DD8L-02 total Threads into the /4 (0.75 ) NPT opening on each side of engine block. 44 Customer Service: hotstart.com

45 In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. In-block Heaters C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required MAN D2840 D2842 D2848 PF2-00 PF Replace oval shaped plate in lower water pipe on right side of engine. D2866 D2876 PF5-006 PF Replace bolt plate on left side of engine. May require adapter if bolt opening is not available on engine. Consult customer service. Massey Ferguson cylinder 4 cylinder 6 cylinder PER-75FP PER-0FP PER-752FP PER-02FP Mounts in any of the -/4 (.25 ) core plug openings in the engine. YES Mercedes enz ME904 ME906 ME924 ME925 PF0-00 PF Replaces mm core plug on right rear of engine. Navistar/International V800 (796 CID) AC-0 CATV-5 AC-02 CATV Threads into a NPT opening in the oil cooler bonnet. INLINE 6 CYLINDER all series 2,, 44, 46, 466 & 50 INTA-2 INTA-0 INTA-22 INTA Replaces third or fourth core plug on left side of engine. Element should point toward O clock position. 7.L & T and later TF DD8L-0 TF DD8L Mounts in the /4 (0.75 ) NPT plug in the engine s block. 9.0L V8 diesel INT9-0F INT9-02F 000 Mounts in a core plug. Oliver ALL EXCEPT 265, 65 & 900 TF DD8L-0 TF DD8L Threads into a /4 (0.75 ) NPT opening in the block. Onan See Cummins A Series Perkins PER-75FP PER-0FP PER-752FP PER-02FP Mounts in the -/4 (.25 ) core plug opening on right side of engine FP5-00 FP Replaces core plug on left front of engine. Customer Service: hotstart.com 45

46 In-block Heaters In-block heaters are complete with 2-wire w/ground 6 (.8m) HPN cord and plug. For cord replacements or Y Thermocord energy saver, please reference page 48. C US Engine Model Part Number Part Number Watts Application Information Heat Shield Photo 20V V Required Perkins continued 700 Series FP5-00 FP Replaces 50mm core plug located at rear of head. 800 Series PF5-00 PF Mounts in oval shaped plate on the left front of the block. 004 (right side) FR FR0-000 PER-5FP FR FR PER-52FP Mounts in the -/2 (.5 ) core plug opening on right side of engine. 004 (left side) PER-75FP PER-0FP PER-752FP PER-02FP Mounts in the -/4 (.25 ) core plug opening on left side of engine. 006 (6 Cyl) A & PER-5FP PER-52FP 500 Mounts in the -/2 (.5 ) core plug on right side of engine. 0C FR WOC FR WOC 50 Replaces -/4 (.25 ) core plug on right rear of engine. Element should point towards O clock position. 04 (4 Cyl) C & D PER-75FP PER-0FP PER-752FP PER-02FP Mounts in -/4 (.25 ) core plug opening on right side of engine. Volvo D9 PF5-007 PF Replaces oval shaped plate on right side of engine. D2C Prior to Serial # PF5-005 PF Replaces oval shaped plate on right side of engine. YES D2C After Serial # PF2-002 PF Replaces oval shaped plate on right side of engine. YES TD, TD6, TD70, TD7, TD00, TD0, VE0, TD20, TD2 VT6-0 VT Mounts into threaded opening on left side of engine. Yanmar T72HLE 4TN82E D4T YYDXL4.4 TF40-00 NONE 400 NPT No replacement cord available. NOTE: The only replacement part for in-block heaters is the power cord. Please see the power cord section on page 48 for the proper replacement cord set. For thermostat control of in-block heaters, see page 48. The energy saver Thermocord is available in various temperature ranges. Supplemental heat for engines using in-block heaters can be achieved by the installation of lube-oil heaters in the oil pan. Reference pages 20 and 2 of this catalog or consult factory. 46 Customer Service: hotstart.com

47 Instructions for: In-block heaters Please refer to specific instructions that accompany heater. In-block Heater Installation THREADED PLUG TYPE HEATERS A. Drain the cooling system.. Remove the recommended core plug. (See instructions with heater) C. Apply teflon tape to pipe threads or grease to O-ring. D. Thread heater into engine. Please follow these steps to ensure proper operation of your HOTSTART in-block heater.. Align cord with pins on the heater and press the cord into the heater. Place clamp around cord & heater. DO NOT PLUG IN HEATER YET! 2. Route the cord, keeping away from hot or moving surfaces.. Re-fill the cooling system. Run engine until engine thermostat opens and continue running for another 20 minutes to eliminate air. 4. Stop engine and let cool. Check for leaks. Check coolant level. 5. Plug heater into power supply and test for proper operation. lock should feel warm near heater. PLATE TYPE HEATERS A. Drain the cooling system.. Remove the recommended plate. (See instructions with heater) C. Clean the gasket area. D. Apply gasket sealant to plate and engine surfaces. E. Insert heater into engine. Tighten bolts. Please follow these steps to ensure proper operation of your HOTSTART in-block heater.. Align cord with pins on the heater and press the cord into the heater. Place clamp around cord & heater. DO NOT PLUG IN HEATER YET! 2. Route the cord, keeping away from hot or moving surfaces.. Re-fill the cooling system. Run engine until engine thermostat opens and continue running for another 20 minutes to eliminate air. 4. Stop engine and let cool. Check for leaks. Check coolant level. 5. Plug heater into power supply and test for proper operation. lock should feel warm near heater. FREEZE (CORE) PLUG TYPE HEATERS A. Drain the cooling system.. Remove the recommended core plug. (See instructions with heater) C. Clean, smooth and dry core plug opening. D. If retaining ring style, apply a light coat of grease to the O- ring and core plug opening. If press-in style, apply a light coat of high-temperature, highstrength retaining compound (Loctite 640 recommended). E. Insert heater into engine and position properly. Push the heater into the engine by hand, then tap in using a suitable tool until flange is even with engine block. Please follow these steps to ensure proper operation of your HOTSTART in-block heater.. Align cord with pins on the heater and press the cord into the heater. Place clamp around cord & heater. DO NOT PLUG IN HEATER YET! 2. Route the cord, keeping away from hot or moving surfaces.. Re-fill the cooling system. Run engine until engine thermostat opens and continue running for another 20 minutes to eliminate air. 4. Stop engine and let cool. Check for leaks. Check coolant level. 5. Plug heater into power supply and test for proper operation. lock should feel warm near heater. Customer Service: hotstart.com 47

48 Replacement Cords & Thermostats For use with In-block Heaters Cord Length Plug Style 20 Volt Volt STYLE C US 6.8m IM6-IN IM6-2IN 5amp, 20V.4m IM-IN IM-2IN Heat Shield 6 4.8m Cord Length IM6-IN IM6-2IN Plug Style 20 Volt Volt 5amp, V Fits most competitor's applications. STYLE 2 C US HS 6.8m 2 PR72T 2PR72T 5amp, 20V.4m 2 PR2T 2PR2T Use when exhaust manifold or turbo come close to heater termination m 2 PR92T 2PR92T 5amp, V IM6-IN PR72T Thermocord for In-block Heaters C US NOTE: When ordering in-block heater and thermocord, place suffix WOC (which stands for without cord) after the heater model number to save cost as the standard 6 (.8m) heater cord is replaced by the Thermocord harness. Part No. Volts Thread Size Temp Range TC /2" F (8-49C) TC /2" F (49-C) TC /2" F (8-49C) TC /2" F (49-C) 4.2m ft. m ft. m TC /2" F (27-8C) TC0-866 /2" F (27-8C) Heater shown for illustration purposes only 48 Customer Service: hotstart.com

49 Model Number 20 Volt Model Number Volt Flush Mount Kits for In-block Heaters Cord Length Plug Style IM6-IN-FM IM6-2IN-FM 6 (.8.m) 2 IM-IN-FM IM-2IN-FM (.4m) 2 IM6-IN-FM IM6-2IN-FM 6 (4.8m) 2 Kits include: PR- style cord (shown on page 48), recessed male receptacle and hinged flip cover. C US Flush Mount Kits & Accessories. 79mm.0 76mm Flush Mount Kits for Thermosiphon Engine Heaters Model Number Volts Amps For Heater with Wattage of: FM to 800 FM to 000 FM to 2250 Kits include: Recessed male receptacle with 6 (.8m) cord (no female connectors), hinged flip cover and female connector. C US. 79mm.0 76mm Other Accessories Recessed Male Receptacle with 6 (.8m) cord (no female connectors) Model Number Volts Amps RM5-5 RM6-5 RM5-2Ø RM6-2Ø Model Number Volts Amps Female Connector - for extension cords FMG2ØA FM2G2ØA 20 5/20 5/20 Hinged Cover Model Number Description.25 82mm. 79mm *FC-KH FC-KH-C lack/hotstart Logo Chrome/HOTSTART Logo.0 76mm *Standard with kit Model Number Plug Housing A-222-PH Customer Service: hotstart.com 49

50 Specifying an Engine Heater. Determine the best type of heater to be used for the application. In-block or Thermosiphon Engine Heater? Weathertight model for all indoor or outdoor applications (hospital, communications building, shopping mall, pump station, off-road equipment). Hazardous Location model (off-shore platform, oil rig, gas compression station). 2. Determine engine size. Cubic inch or litre displacement.. Determine wattage required by using this general formula: watts x cubic inch displacement = watts required. Example: Engine is 855 C.I.D. 855 x = Requirement is 2500 watt heater. This formula is a very good rule of thumb to use down to 0 F (-8 C) ambient temperature. This formula will generally hold engine temperature at approximately 00 F (8 C) above ambient. Engines over 250 CID (20L) and V engines require forced circulation preheating systems (CTM, CSM models see pages 4-5). 4. Now that you have the required wattage, you need to determine: Voltage available that will power the heater (20,, 277,, 80, ). Is the power source Single Phase or Three Phase? 5. For thermostat selection, determine the desired engine temperature to be maintained. 00 F (8 C) to 20 F (49 C) applies 95% of the time. However, specifications vary with respect to the user and a higher or lower range may be required. You now have the specifications needed to select the required engine preheater from the many products listed in this catalog. For other technical information and installation tips, see pages 8 and 47. If you have other questions or need additional assistance, please contact our customer service department. Conversion Factors Litres x.0567 = Quarts Quarts x = Litres Litres x = Gallons Gallons x.7854 = Litres Cubic Inches - Litres Conversion Chart Cubic Inches Litres Cubic Inches Litres Cubic Inches Litres Cubic Inches x = Liters Liters x = Cubic Inches Temperature Fahrenheit Celsius -40 F -40 C -0 F -4 C -20 F -29 C -0 F -2 C 0 F -8 C 0 F -2 C 20 F - 7 C 0 F - C 40 F 4.5 C 50 F 0.0 C F 5.5 C 70 F 2.0 C 80 F 27.0 C 90 F 2.0 C 00 F 8.0 C 0 F 4.0 C 20 F 49.0 C 0 F 54.0 C 40 F.0 C 50 F 65.5 C F 7.0 C 70 F 77.0 C 80 F 82.0 C 90 F 88.0 C 200 F 9.0 C 20 F 99.0 C C x = F (F - 2) x 0.55 = C 50 Customer Service: hotstart.com

51 HOTSTART forced circulation preheating systems are ideal for engines ranging in size from 0L to the largest displacement currently in production. These systems are designed specifically for installation on a generator, compressor package, marine engine or locomotive. HOTSTART offers forced circulation heating systems for coolant heating, lube oil heating and diesel fuel heating. Combination systems are also available that heat and circulate coolant and oil in one pre-assembled unit. Complete with all necessary components and controls, these automated systems are available in various wattage, voltage and phase combinations to accommodate most large industrial preheating needs. Forced Circulation Heating Systems For additional information regarding HOTSTART s forced circulation heating systems, please visit or contact HOTSTART and have all your questions answered by one of our engine heating product specialists. CMM/CLM Models Coolant-only Heating Systems Voltage Range: V Heat Power: 6-44 kw CLA/CLE Models Coolant heating systems are designed to heat and circulate coolant throughout the engine's cooling system to efficiently maintain an engine at optimum starting temperatures. Maintaining jacket water temperatures ensures easy starting, reduces harmful emissions at start-up and allows engines to go to full power without needless idling. OSM Model Oil-only Heating Systems Voltage Range: V Heat Power: - 2 kw OLA/OLE Models Oil heating systems provide uniform heating to the oil throughout the engine oil sump and external piping, enhancing engine or compressor availability and decreasing wear and tear from cold startups. Coolant and Oil Heating Systems OCLA/OCLE Models Auxiliary Power Unit for Locomotive Engines Voltage Range: 20 V, 400 V Heat Power: Oil kw Heat Power: Coolant kw The HOTSTART APU allows an idling locomotive to be shut down in cold weather at any location. This self-contained system runs off the locomotive s fuel supply. It will maintain water temperature at 00 F (8 C) above ambient and provides cab heat. Customer Service: hotstart.com 5

52 Corporate and Manufacturing Headquarters 572 E Alki Ave Spokane, WA 9922 USA sales@hotstart.com Oil & Gas Office 272 Provincial lvd Suite 70 Katy, TX USA oil.gas@hotstart.com Europe Office HOTSTART GmbH Am Turm Siegburg Germany europe@hotstart.com Asia Pacific Office HOTSTART Asia Pacific Ltd F, Honkomagome unkyo-ku, Tokyo -002, Japan apac@hotstart.com Customer Services Warranty Information To better serve you, HOTSTART provides a customer service department to answer all your engine heating concerns and questions or to take your sales order. Customer Service Department: Sales orders and requests for quotes can also be faxed to our toll-free FAX line. Toll-free FAX line: The warranty below has been drafted to comply with the Federal Law applicable to products manufactured after December, 976. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. HOTSTART products are warranted against defects in workmanship and materials. No other express warranty, written or oral, applies. No person is authorized to give any other warranty or assume any liability except by written statement from an officer of HOTSTART, Inc. The warranty extends for twelve months from date of shipment from factory or authorized distributor. Products must be installed and maintained in accordance with HOTSTART, Inc. instructions. Users are responsible for the suitability of the products to their application. There is no warranty against damage resulting from corrosion, misapplication, improper specification or other operating conditions beyond our control. Claims against carriers for damage in transit must be filed by the buyer. Absolutely no material can be returned to HOTSTART, Inc. without prior factory authorization. Upon factory authorization, return the defective part or product, freight prepaid, to: HOTSTART, 572 E Alki Ave, Spokane, WA Defective items will be repaired or replaced, at our option, at no charge. Such repair or replacements is the exclusive right of HOTSTART, Inc. HOTSTART, Inc. is not liable for labor costs incurred in removal, reinstallation, or unauthorized repair of the product or for damage of any type whatsoever including incidental or consequential damage. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the preceding limitation or exclusion may not apply to you. HOTSTART, Inc. Distributor

IMC-700 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES

IMC-700 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES IMC-700 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES TALE OF CONTENTS HEATER INSTALLATION Page 22 (Thermosiphon) Page 5 (In-block) HOW TO SPECIFY AN ENGINE HEATER Page 54 CONVERSION

More information

IMC-800 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES

IMC-800 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES IMC-800 PRODUCT CATALOG ENGINE HEATERS OIL HEATERS CONTROLS ACCESSORIES TALE OF CONTENTS HOTflow ONLINE TECHNICIAN CERTIFICATION TRAINING Page 7 HEATER INSTALLATION Page 8 (Thermosiphon) Page 47 (In-block)

More information

P R O D U C T S C A T A L O G IMC-700 ENGINE HEATERS CONTROLS OIL HEATERS ACCESSORIES

P R O D U C T S C A T A L O G IMC-700 ENGINE HEATERS CONTROLS OIL HEATERS ACCESSORIES P R O D U T S A T A L O G IM-700 ENGINE HEATERS ONTROLS OIL HEATERS AESSORIES SETION HEATER INSTALLATION Page 9 Part number matrix for tankstyle heaters Page 0 Tank-style Page 5 In-block Page 56 How to

More information

IMC-600. Product Catalog. Engine Heaters Oil Heaters Controls Accessories

IMC-600. Product Catalog. Engine Heaters Oil Heaters Controls Accessories IMC-600 Product Catalog Engine Heaters Oil Heaters Controls Accessories HOTSTART... YOUR ENGINE HEATING EXPERTS! HOTSTART was established in 94 with the original patent for engine coolant heating. We design

More information

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories IM-400 Product atalog Engine Heaters Oil Heaters ontrols ccessories Section Three Kim-Stat ontrols Pressure Switch Magnetic ontactors Junction oxes omplete ontrol Systems for manual and automatic start

More information

HDT-400. Product Catalog. Engine Heaters Battery Pads & Wraps Oil Heaters Replacement Parts

HDT-400. Product Catalog. Engine Heaters Battery Pads & Wraps Oil Heaters Replacement Parts HDT-400 Product Catalog Engine Heaters Battery Pads & Wraps Oil Heaters Parts KIM HOTSTART... YOUR ENGINE HEATING SOLUTION! Kim Hotstart was established in 1942 with the original patent for engine coolant

More information

Tubular Industrial Process

Tubular Industrial Process consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug

More information

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call  2-1/2 Pipe Thread Heaters Pipe Thread Heaters Construction Features " -/" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging hex, thread and riser assures reliability.

More information

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company. www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6

More information

TM Series. Induced Draft, Counter Flow Optional Accessories

TM Series. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

WATER HEATER PARTS CTN. QTY.

WATER HEATER PARTS CTN. QTY. WATER HEATER PARTS Drip Pans & Accessories 40-0050 1 Bottom or side drain drip pan 30 & 40 gal. Capacity Styrene 40-0100 1 Bottom drain drip pan 30 & 40 gal. Capacity Aluminum 40-0110 1 Side drain drip

More information

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number: Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,

More information

Tubular Industrial Process

Tubular Industrial Process Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round

More information

Immersion Heaters. Screw Plug Immersion Heater

Immersion Heaters. Screw Plug Immersion Heater Screw plug immersion heaters are ideal for direct immersion heating of liquids, including all types of oils and heat transfer solutions. Available in a variety of sizes, screw plug immersion heaters feature

More information

Indirect Fired Water Heater

Indirect Fired Water Heater Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite

More information

Paragon. Induced Draft, Counter Flow Optional Accessories

Paragon. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane

More information

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. 1 2-1/2 Pipe Thread Heaters Construction Features 1" 2-1/2" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging of hex, thread and riser assures reliability. Element

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

A HEATER KIT With Diesel Engine Connection Fittings

A HEATER KIT With Diesel Engine Connection Fittings A-12142 HEATER KIT With Diesel Engine Connection Fittings Figure 1 (General Layout and Parts I.D.) Page 1 of 6 Read these instructions and identify all components. Please retain these instructions for

More information

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...

More information

MOUNTING INSTRUCTIONS

MOUNTING INSTRUCTIONS A-12093 JDX 2014 HEATER KIT With Gas Engine Connection Fittings 2014 and Newer ROPS Cabs A-12098 (Kit A-12092, Diesel Engine Connection Fittings are sold separately for diesel models) 12VDC, 2-Speed, 15,000

More information

AccuBrine automated brine maker Technical Specifications

AccuBrine automated brine maker Technical Specifications Cargill Deicing Technology AccuBrine automated brine maker Technical Specifications All 4 models included Automated Blending System Model (ABM) Automated Blending Remote Truck Fill Model (ABRTF) Automated

More information

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D. A-11978 HEATER KIT Figure 1 (General Layout and Parts I.D.) Read these instructions and identify all components. Please retain these instructions for future reference and parts ordering information. Refer

More information

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories IMC-400 Product Catalog Engine Heaters Oil Heaters Controls ccessories Section Four attery Pads attery Wraps Single or Multiple pplications Silicone Hot Pads 35 attery Heating Pads fully charged battery

More information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Band Heaters W A T L O W. Special Mica Barrel and Nozzle W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge

More information

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION E L E CT R I C DUCT HEATER FLIPPABLE SHOWN RENEWAIRE ERV + ELECTRIC DUCT HEATER: A SINGLE-SOURCE SOLUTION RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

More information

Heater Inspection Guidelines

Heater Inspection Guidelines www.hotstart.com Heater Inspection Guidelines INSTRUCTIONAL VIDEO PROVIDING ADDITIONAL SUPPORT CAN BE FOUND AT http://hotstart.com/home/resources/installation-instructions/ HOTSTART heaters utilize a standard

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR SPECIFICATIONS MODEL E859C MINI DEHYDRATOR 1 DEHYDRATION TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (dehydrating, de-aerating, purifying

More information

Cool IR. Model C104 - Cooling System. Instruction Manual

Cool IR. Model C104 - Cooling System. Instruction Manual Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model MSE Shipboard Electric Water Heater 6-119 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining

More information

PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com

PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL franklinwater.com PACKAGED SYSTEMS Inline Controls... 2 FLW...3 SWC & SWP...4 ADJ...5 CTL 6 Inline Pressure Boosting... 7 Inline 400...7 Inline

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

Easy Installation & Service

Easy Installation & Service Water Commercial Electric Heavy Duty Water Heaters Heavy Duty Electric commercial water heaters are available in 50 through 175 gallon capacities. All models quick ship from Rheem warehouses no deposit

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

Thermostats and Accessories

Thermostats and Accessories Thermostats and Accessories SERIES EHG...641 SERIES EHG SL10...643 ST10 and ST207...647 Bulb and Capillary...649 Low Liquid Level Sensors...653 Protective Wells...654 639 640 WATLOW SERIES EHG Many applications

More information

Life insurance for your electronics

Life insurance for your electronics ELECTRO-TECHNOLOG FOR INDUSTR Life insurance for your electronics The formation of condensation is one of the biggest dangers for electrical enclosures. As long as they are working under load, their own

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Overview consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. are screwed directly through a threaded opening in

More information

INSTRUCTION MANUAL with ILLUSTRATED PARTS LIST for BLOCK HEATER Part Number (120 VAC) and (240 VAC)

INSTRUCTION MANUAL with ILLUSTRATED PARTS LIST for BLOCK HEATER Part Number (120 VAC) and (240 VAC) 090898 INSTRUCTION MANUAL with ILLUSTRATED PARTS LIST for BLOCK HEATER Part Number 287632-1 (120 VAC) and 287632-2 (240 VAC) Hobart Brothers Company Ground Power Division Troy, Ohio 45373 U.S.A. This page

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model MSE Shipboard Electric Water Heater 6-120 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining

More information

Thermostat KPU. Data sheet

Thermostat KPU. Data sheet Data sheet Thermostat KPU The KPU Thermostats are temperature controlled electrical switches, which are applied for regulation and safety monitoring of refrigeration and air conditioning systems. KPU sensors

More information

"ER" Series Electric Humidifier

ER Series Electric Humidifier ER-1 Standard Water "ER" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODEL: CFF-500 Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: May 10, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Powers Controls ET 134 Low Temperature Detection Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SN Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing

More information

HWD-2110 Hot Water Dispenser

HWD-2110 Hot Water Dispenser User s Guide t f Touch Function Selector Technology HWD-2110 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine. Temperature On Demand US design patent applied for. Other

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage NEMA 4 enclosure standard

More information

MARATHON HEATER. File # E Made in USA

MARATHON HEATER. File # E Made in USA MARATHON HEATER S I L I C O N E R U B B E R H E A T E R S File # E202904 Made in USA Wire wound Silicone Rubber Heaters Marathon Heater flexible heaters provide outstanding performance in applications

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic Spec-00698 APH FX ( Protective Cooling Air Conditioners N28 Narrow Indoor/Outdoor Base Models Features R407c and R134a earth-friendly refrigerants and RoHS compliant Models for 115, 230 AC volt power input

More information

Tubular Industrial Process

Tubular Industrial Process Alternate NEMA 1 Housing Type 3N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters Screw Plug Immersion Heaters TYPE 4N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters

More information

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

Agency Certifications, Recognition and Approvals

Agency Certifications, Recognition and Approvals Agency Certifications, Recognition and Approvals WATROD and FIREBAR Element...563 Agency Certifications, Recognition and Approvals WATLOW 561 562 WATLOW WATROD and FIREBAR Element Agency Recognition UL

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump

More information

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508 Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional

More information

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for T-333 Manual INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for Rooftop Energy Storage Systems (ESS) AIR COOLING UNIT 77-62186-00 THRU -04 & 77-62203-00 T-333 REV. 03/2012 2012 Mobile Climate Control

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model ME Shipboard Electric Water Heater 6-119 Gallon Capacity, Up To 12 KW, Single Phase Marine Approvals United States Coast Guard (USCG) conformance and American Bureau of Shipping

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018 Installation and Operation Instructions Versa TM Screw Plug Oil & Water Immersion Heater 1 PD449-2 161-306451-003 January 2018 B 6" 1-13/16 Cold (Ref.) 9-1/8" 2-3/4 Min. Hole Size 6" 7-7/8" Thermowell

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL 216300-000 rev2 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OSE OSX (this page intentionally left blank) IDENTIFYING YOUR SYSTEM IOM216300-000 The HOTSTART

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.18

MODEL CMA-180UC PARTS MANUAL Rev 1.18 MODEL CMA-180UC PARTS MANUAL Rev 1.18 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

Technical Specification VFD

Technical Specification VFD Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.16

MODEL CMA-180UC PARTS MANUAL Rev 1.16 MODEL CMA-180UC PARTS MANUAL Rev 1.16 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification

More information

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR ELECTRIC ON-DEMAND TANKLESS WATER HEATERS: SpecAdvantage with PhD Technology SafeAdvantage with PhD Technology 208 and 480 VAC three phase 32 144 kw 600

More information

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure 3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure Diecast aluminium enclosure with explosion proof (Ex-e) and flame proof (Ex-d) protection suitable for use in hazardous areas,

More information

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to

More information

Electric Duct Heaters

Electric Duct Heaters Electric Duct Heaters 12541_Tutco_Catalog.indd 1 3/4/11 8:46:01 AM TYPICAL HEATER CONSTRUCTION TUTCO, the world s largest supplier of open coil heating elements, produces the highest quality products in

More information

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

PROVIDES TEPID WATER FOR EMERGENCY SHOWER PROVIDES TEPID WATER FOR EMERGENCY SHOWER Model EMV FEATURES Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop

More information

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual

More information

Machine Tool Coolant Units

Machine Tool Coolant Units Machine Tool Coolant Units Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes /5 HP fan-cooled motor Vertical machine coolant VMC- Capacity: GPH @ ' 9 LPH @. m Liquid Temperature:

More information

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions Heavy duty industrial cart options simplify moving heater to various locations 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design

More information

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers HEATING & COOLING Product Data 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers Model 49FH Model 49WS Model 49BF Model 49FP Model 49BG All Carrier humidifiers are designed for easy installation and quiet operation

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

water source / fan coils

water source / fan coils MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without

More information

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models) Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine.

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine. User s Guide t f Touch Function Selector Technology HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine. Temperature On Demand US design patent applied for. Other

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information