1 Dometic Environmental Corporation Air Handler Wiring Diagrams L-2295B Revised:
2
3 Air Handler Wiring Diagrams - Table of Contents Page Drawing No. Description 4 H D NO-VALVE Air Handler Operation Instructions 5 H A AH-Passport II to generic elec box 6 H B AH-Passport I/O to generic elec box 7 H Elite-Passport I/O to AT wiring hookup schematic 8 H Elite-Passport I/O to AT-DC wiring hookup schematic 9 H E 2-Knob AH control to generic elec box (MCP-AH) 10 H D 3-Knob AH control to generic elec box (MCP-AH) 11 H A FX/FX-Maxx to generic elec box 12 H D AT4F(Z) Wiring Diagram 13 H D AT6-18F(Z) Wiring Diagram 14 H F AT6-36HV(Z) Wiring Diagram 15 H D AT6-36HV(Z) with Shielded Cable Wiring Diagram 16 H AT6-36DCZ Label, Wiring Diagram 17 H B AT6-36DCZ 415V Heat, Label, Wiring Diagram 18 H ATL 16K(Z) 115V-230 V, Label, Wiriing Diagram 19 H K AT18/24/36MU - 115, 208,230VAC/50-60HZ/ 1Ø Fresh Air Makeup 20 H A AT18/24/36MU 208,230VAC/50-60Hz/1Ø Fresh Air Makeup 21 H B AH Passport I/O to DC Blower 22 H C AH6-36K-SLL Wiring Diagram Sticker 23 H C AH6-24K-BT(Z) Wiring Diagram Sticker 24 H B AH24-32FBZCH3 to AH-Passport I/O 25 H E AH24/32FBZ3 Wiring Diagram Sticker 26 H L Slim Line/BlowThru - Remote Box 27 C A Slim Line/BlowThru - Remote Box with COS (CA) AT Air Handler with PLTX-HVSTAT (after Sept. 2005) DC AT-DC Air Handler with PLTX-HVSTAT SMXII AT Air Handler with PLTX-HVSTAT (before Sept. 2005) AT-COS Air Handler with PLTX-HV AT FAMU with PLTX-HVSTAT AT-COS Air Handler with TS3-ZCB AT Air Handler with PLTX-HVSTAT and VSD AT-COS Air Handler with NPLTX - SMX Net 36 C A AT6-36HV(Z) with COS Air Handler diagram 37 C AT4F(Z) with COS Air Handler diagram 38 C AT6-18F(Z) with COS Air Handler diagram
4 4
5 5
6 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 12/22/04 UPDATE FOR AT AIR HANDLER,CAD DRR JES B 11/14/05 UPDATED FOR EH RELAY REMOVAL, CAD DRR MFG ELECTRICAL BOX J-4 ALT. AIR TRANS J-3 OAT L1 L2 L1 L2 TERMINAL BLOCK LABEL AH-PASSPORT I/O #H JP3 LOW HIGH PRESSURE SWITCHES JP1* J-5 SERVICE/H2O COMP FAN PUMP PUMP L 2 L 2 L 2 L 1 HEATER *SEE NOTE #1 NC NO L2 FAN L2 HEATER RELAY (SEE NOTE #2) COMP L 1 COM PASSPORT I/O VALVE L2 NOT USED HEATER VALVE FAN L 1 L 1 L1 VALVE L1 FAN L1 J-2 DISPLAY DISPLAY PANEL OPTIONAL ALT. AIR SENSOR OPTIONAL OUTSIDE AIR SENSOR WATER INLET SENSOR NOTE #1: JUMPER #1 (JP1) MUST BE CUT WHEN USING AS A CHILLED WATER AIR HANDLER CONTROLLER. NOTE #2: ON BOARDS WITHOUT A HEATER RELAY INSTALLED, CONNECT HEATER L1 TO TERMINAL STRIP LOCATION MARKED AS "HEATER L1" L1 N/L2 GND /50-60/1 POWER SUPPLY #12 SEE NOTE #2 AIR HANDLER JUNCTION BOX REFER TO THE DIAGRAM INDICATED ON THE AIR HANDLER'S LABEL. A COPY IS INSIDE THE JUNCTION BOX. NOTE: "AT" AIRHANDLERS ONLY NEED ONE OF THESE WIRES. HOWEVER, IT MUST BE AT LEAST #12 IF THE UNIT HAS ELECTRIC HEAT. Dometic Corporation DATE: SCALE: 7/30/03 NTS BY: APR BY: AH PASSPORT I/O GENERIC WIRING DIAGRAM DRR JES PART NUMBER: CREATED BY CAD H B 6
7 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Corporation Marine Air WIRING SCHEMATIC DATE: SCALE: Elite or Passport I/O to AT/other Air Handlers(NOT DC) 4/17/07 NTS BY: APR BY: DRR JES PART NUMBER: H O.I. 7
8 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Corporation Marine Air WIRING SCHEMATIC DATE: SCALE: 4/17/07 NTS Elite or Passport I/O to AT-DC Air Handlers BY: APR BY: DRR JES PART NUMBER: H O.I. 8
9 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 7/6/00 MOVED WIRES AND CHANGED COLORS,CAD MJS JES B 6/24/03 SHOW GENERIC JUNCTION BOX,CAD DRR JES C 12/22/04 UPDATED FOR AT AIR HANDLERS,CAD DRR JES D 1/6/05 REMOVED DUPLICATE NOTE,CAD DRR JES E 5/26/05 UPDATE TO LATEST WIRE COLOR STANDARDS,CAD DRR JES Dometic Corporation Marine Air AH 2-KNOB CONTROL NO WATER VALVE DATE: SCALE: OR HEATER OPTION, VAC/50-60HZ/1Ø 3/20/00 NTS BY: APR BY: MJS JES PART NUMBER: H E 9
10 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 12/22/04 UPDATED FOR AT AIR HANDLERS, CAD DRR JES B 5/26/05 UPDATE TO LATEST WIRE COLOR STANDARDS,CAD DRR JES C 8/16/05 ADDED NOTE AND REFERENCES,CAD DRR JES D 8/23/05 ISED WIRE SIZES FOR CHANGE-OVER SW,CAD DRR JES Dometic Corporation Marine Air 3-KNOB AIRHANDLER CONTROL W/COS DATE: SCALE: 7/30/03 NTS BY: APR BY: DRR JES PART NUMBER: H D 10
11 11
12 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 12/22/04 UPDATE FOR CRUISAIR NOMENCLATURE,CAD DRR JES B 1/6/05 ADDED NOTE FOR COMMONIZATION OF MODELS,CAD DRR JES C 2/15/05 ADDED OPTIONAL POLARIZED PLUG & NOTE 2,CAD DRR JES D 3/11/05 ADDED JUMPER TO TERM BLOCK,CAD DRR JES (2) O B G W L1 POWER L2/N L2/N (1) BLOWER BLK VALVE ORG BROWN CHANGE-OVER THERMOSTAT RED BLACK (1) DO NOT REMOVE BLOWER L2/N JUMPER UNLESS A VSD FAN SPEED CONTROL IS INSTALLED. (2) OPTIONAL POLARIZED PLUGS GREEN#16 ORG#18 BLACK#16 GREEN#16 BLACK#16 GREEN#18 YEL/GRN#16 BLACK BLACK#16 BLACK BLACK#16 ORG#18 BROWN#18 RED#18 BLACK#18 FAN MOTOR 4K FASCO NOTE: CHANGE-OVER THERMOSTAT TYPICALLY CONNECTS DIRECTLY TO THE POWER LOGIC CONTROL BOX WHEN INSTALLED BY CUSTOMER. HOWEVER, IT WILL BE CONNECTED AS SHOWN IF CONNECTED AT DOMETIC FACTORY AND INDICATED BY "COS" IN THE MODEL NUMBER. CHANGE-OVER THERMOSTAT VALVE MOTOR ORANGE ORANGE RED#18 BLACK#18 BROWN#18 GREEN#18 ORG#18 ORG#18 CREATED BY CAD Dometic Corporation DATE: SCALE: 4/19/04 NTS BY: APR BY: LABEL, WIRING DIAGRAM AT4F(Z) DRR JES PART NUMBER: H D 12
13 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 12/22/04 UPDATE TITLE TO INCLUDE CRUISAIR,CAD DRR JES B 1/6/05 ADDED NOTE FOR COMMONIZATION OF MODELS,CAD DRR JES C 2/15/05 ADDED OPT POLARIZED PLUGS & NOTE 2,CAD DRR JES D 3/11/05 ADDED JUMPER TO TERM BLOCK,CAD DRR JES (2) O B G W W B (2) L1 POWER L2/N L2/N (1) BLOWER BLK VALVE ORG BROWN CHANGE-OVER THERMOSTAT RED BLACK AUX HEAT (1) DO NOT REMOVE BLOWER L2/N JUMPER UNLESS A VSD FAN SPEED CONTROL IS INSTALLED. (2) OPTIONAL POLARIZED PLUGS GREEN#18 GREEN#16 HR YEL#12 ORG#18 WHITE#16 RED#16 ORG#18 BROWN#18 RED#18 BLACK#18 HR YEL#12 GREEN#16 WHITE#16 YEL/GRN#16 WHITE RED#16 RED FAN MOTOR 6-18K FASCO NOTE: CHANGE-OVER THERMOSTAT TYPICALLY CONNECTS DIRECTLY TO THE POWER LOGIC CONTROL BOX WHEN INSTALLED BY CUSTOMER. HOWEVER, IT WILL BE CONNECTED AS SHOWN IF CONNECTED AT DOMETIC FACTORY AND INDICATED BY "COS" IN THE MODEL NUMBER. CHANGE-OVER THERMOSTAT (IF APPLICABLE) VALVE MOTOR (IF APPLICABLE) OVERLOAD HR YEL#12 ORANGE ORANGE OVERLOAD RED#18 BLACK#18 BROWN#18 GREEN#18 ORG#18 ORG#18 HR YEL#12 HEATERS (IF APPLICABLE) CREATED BY CAD Dometic Corporation DATE: SCALE: 4/19/04 NTS BY: APR BY: LABEL, WIRING DIAGRAM AT6-18F(Z) DRR JES PART NUMBER: H D 13
14 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. (2) O G B W DATE ISION DESCRIPTION APR A 2/26/04 ISED WIRE COLORS FOR VALVE,CAD DRR JES B 4/16/04 ISED WIRING & WIRE COLORS,CAD DRR JES C 12/22/04 ISED TITLE,CAPS FROM LEADS TO SPADES,CAD DRR JES D 1/6/05 ADDED NOTE FOR COMMONIZATION OF MODELS,CAD DRR JES E 2/15/05 ADDED OPTIONAL POLARIZED PLUGS & NOTE 2,CAD DRR JES F 3/11/05 ADDED JUMPER TO TERM BLOCK,CAD DRR JES W B (2) POWER L1 L2/N BLOWER L2/N (1) BLK VALVE ORG BROWN CHANGE-OVER THERMOSTAT RED BLACK AUX HEAT (1) DO NOT REMOVE BLOWER L2/N JUMPER UNLESS A VSD FAN SPEED CONTROL IS INSTALLED. (2) OPTIONAL POLARIZED PLUGS GREEN#18 GREEN#16 HR YEL#12 ORG#18 BLUE#16 BLACK/BLUE BLACK#16 ORG#18 BROWN#18 RED#18 BLACK#18 HR YEL#12 BLACK OR BLUE BROWN OR RED CAP GREEN#16 BLUE#16 YEL/GRN#16 BLUE HEATERS (IF APPLICABLE) BLACK#16 BLACK BROWN#16 BROWN NOTE: CHANGE-OVER THERMOSTAT TYPICALLY CONNECTS DIRECTLY TO THE POWER LOGIC CONTROL BOX WHEN INSTALLED BY CUSTOMER. HOWEVER, IT WILL BE CONNECTED AS SHOWN IF CONNECTED AT DOMETIC FACTORY AND INDICATED BY "COS" IN THE MODEL NUMBER. CHANGE-OVER THERMOSTAT (IF APPLICABLE) FAN MOTOR 6-24K EBM VALVE MOTOR (IF APPLICABLE) HR YEL#12 OVERLOAD ORANGE ORANGE OVERLOAD RED#18 BLACK#18 BROWN#18 GREEN#18 ORG#18 ORG#18 HR YEL#12 CREATED BY CAD Dometic Corporation DATE: SCALE: 1/8/04 NTS BY: APR BY: LABEL, WIRING DIAGRAM AT6-36HV(Z) DRR JES PART NUMBER: H F 14
15 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 1/7/04 CORRECT BLOWER WIRING,CAD DRR JES B 12/22/04 ALLOW CRUISAIR,AT,ISED WIRE COLORS,CAD DRR JES C 1/6/05 ADDED NOTE FOR COMMONIZATION OF MODELS,CAD DRR JES D 5/25/05 ISED WIRE COLORS,CAD DRR JES Dometic Corporation DATE: SCALE: AT6-36HV(Z), AH6-18DT2(Z), AH6-18FD(Z)EBM SHIELDED BLOWER 1/2/04 NTS BY: APR BY: DRR JES PART NUMBER: H D 15
16 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR YEL/GRN#16 BLACK(L1) BLUE(L2) WHITE(ALARM) WHITE(ALARM) L1 L2 (L2) L3 VALVE HEAT DC GND 10VDC 0-10VDC GREEN#16 GREEN#18 BLACK#16 BLUE#16 HR YEL#12 ORG#18 ORG#18 HR YEL#12 WHITE/BLUE#18 RED#18 YELLOW#18 BLUE(DC GND) RED(10VDC) YELLOW(0-10VDC) VALVE GREEN#18 ORANGE#18 ORANGE#18 DC BLOWER HEATER HR YEL#12 OVERLOAD OVERLOAD HR YEL#12 CREATED BY CAD Dometic Corporation DATE: SCALE: 9/13/05 NTS BY: APR BY: 16 LABEL, WIRING DIAGRAM AT6-36DCZ DRR JES PART NUMBER: H O.I.
17 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 6/22/06 MOVED RESISTOR FROM CONT. TO TERM BLOCK,CAD DRR JES B 7/11/06 CHANGED BLUE #18 TO WHT/BLUE #18 PER CAD CDF JES L1 L2 L3 13 A1 T1 T2 T3 14 A2 Dometic Corporation DATE: SCALE: 4/10/06 NTS BY: APR BY: LABEL, WIRING DIAGRAM AT6-36DCZ, 415V HEAT DRR JES PART NUMBER: H B 17
18 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Corporation DATE: SCALE: 4/12/06 NTS BY: APR BY: LABEL,WIRING DIAGRAM ATL16K(Z) 115V-230V DRR RAP PART NUMBER: H O.I. 18
19 19
20 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 1/13/06 REPRESENTATION OF FAN SPEED CONTROL,CAD DRR MFG Dometic Corporation DATE: SCALE: 10/20/05 NTS AT18,24,36MU FRESH AIR HANDLER DC 208,230VAC/50-60Hz/1Ø BY: APR BY: DRR JES PART NUMBER: H A 20
21 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 2/8/06 SHOW ISIONS TO BOARDS,CAD DRR MFG B 2/10/06 ELIMINATED EXTRA L2 WIRES,CAD DRR MFG Dometic Corporation DATE: SCALE: 1/2/06 NTS AH PASSPORT I/O W/ DC BLOWER GENERIC WIRING DIAGRAM BY: APR BY: DRR MFG PART NUMBER: H B 21
22 22
23 23
24 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 2/12/03 ISED TERM BLOCK WIRING,CAD DRR JES B 5/26/05 ISED WIRE COLORS TO NEW STANDARDS,CAD DRR JES Dometic Corporation Marine Air AH24-32FBZCH3 FLY BRIDGE W/EBM BLOWERS DATE: SCALE: 1/24/03 NTS 230VAC/60HZ/1Ø OPTIONAL 3.0KW HEAT BY: APR BY: DRR JES PART NUMBER: H B 24
25 25
26 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR J 8/19/05 PREP FOR AT BOX,CAD DRR JES K 10/5/05 ISED FOR DUAL HEAT,CAD DRR JES L 11/14/05 ADDED POLARIZED PLUGS,CAD DRR MFG F 5/26/05 UPDATE TO LATEST WIRE COLOR STANDARDS,CAD DRR JES G 7/6/05 CHANGE TO CRUISAIR BRAND & WIRE COLORS, CAD DRR MFG H 8/10/05 GND WIRES FROM #16 TO #18,CAD DRR MFG (2) O B G W B W POWER BLOWER VALVE (1) DO NOT REMOVE BLOWER L2/N JUMPER UNLESS A VSD FAN SPEED CONTROL IS INSTALLED. L1 L2/N(1) BLWR L2 BLWR L1 AUX HEAT (2) ONLY AH BT'S WITH DUAL HEATERS USE THE SECOND PAIR OF OVERLOADS AND SECOND HEATER ELEMENT GREEN #18 GREEN #18 HR YELLOW #12 ORANGE #18 WHITE #16 BLACK #16 ORANGE #18 HR YELLOW#12 FAN MOTOR GREEN #18 WHITE BLACK BLUE RED BROWN BROWN/WHITE CAP VALVE MOTOR GREEN #18 ORANGE #18 ORANGE #18 MANUAL OVERLOAD(2) AUTOMATIC OVERLOAD(2) MANUAL OVERLOAD AUTOMATIC OVERLOAD HEATER(2) HEATER CREATED BY CAD Dometic Corporation DATE: SCALE: 8/21/02 NTS BY: APR BY: PART NUMBER: Marine Air LABEL,WIRING DIAGRAM,SL/BT-AT BOX HIGH FAN SPEED CONFIGURATION DRR PJM H L 26
27 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 10/11/05 ISED FOR DUAL HEAT,CAD DRR JES L1 POWER L2/N(1) BLOWER L2/N(1) ORANGE VALVE BLUE CHANGE-OVER THERMOSTAT BROWN RED BLACK AUX HEAT (1) DO NOT REMOVE BLOWER L2/N JUMPER UNLESS A VSD FAN SPEED CONTROL IS INSTALLED. (2) ONLY AH BT'S WITH DUAL HEATERS USE THE SECOND PAIR OF OVERLOADS AND SECOND HEATER ELEMENT GREEN #18 GREEN #18 HR YELLOW #12 WHT/RED #18 BLK/RED #16 ORANGE #16 BLUE #18 BROWN #18 RED #18 BLACK #18 HR YELLOW#12 FAN MOTOR GREEN #18 WHITE BLACK BLUE RED BROWN BROWN/WHITE CAP CHANGE-OVER THERMOSTAT VALVE MOTOR ORANGE ORANGE RED #18 BLACK #18 BROWN #18 GREEN #18 WHT/RED #18 BLUE #18 MANUAL OVERLOAD(2) AUTOMATIC MANUAL AUTOMATIC OVERLOAD(2) OVERLOAD OVERLOAD HEATER(2) HEATER CREATED BY CAD Dometic Corporation DATE: SCALE: BY: APR BY: PART NUMBER: Cruisair LABEL,WIRING DIAGRAM,SL/BT-AT BOX W/COS HIGH FAN SPEED CONFIGURATION 8/19/05 NTS DRR JES C A 27
28 PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Environmental CRUISAIR Wiring Diagram - AT Air Handler with PLTX-HVSTAT SMXII 115/230VAC, with or without elect. heat 8/8/05 BY: CE
29 PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Environmental CRUISAIR Wiring Diagram - AT-DC Air Handler with PLTX-HVSTAT SMXII 115/230VAC, and DC converter with or without elect. heat 3/1/05 BY: CE DC 29
30 DATE ISION DESCRIPTION APR Dometic Environmental CRUISAIR Wiring Diagram - AT Air Handler with PLTX-HVSTAT SMXII 115/230VAC, with or without elect. heat 8/8/05 BY: CE PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. 30
31 DATE ISION DESCRIPTION APR Dometic Environmental CRUISAIR Wiring Diagram - AT-COS Air Handler with PLTX-HV SMXII 115/230VAC, with or without elect. heat 8/8/05 BY: CE PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. 31
32 DATE ISION DESCRIPTION APR Dometic Environmental CRUISAIR Wiring Diagram - AT FAMU Air Handler with PLTX-HVSTAT SMXII 115/20VAC, with electric reheat 8/9/05 BY: CE PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. 32
33 DATE ISION DESCRIPTION APR Dometic Environmental BY: CE PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. CRUISAIR Wiring Diagram - AT-COS Air Handler with TS3 3-Knob Swith 115/230VAC 8/9/05 33
34 DATE ISION DESCRIPTION APR Dometic Environmental CRUISAIR Wiring Diagram - AT Air Handler with PLTX-HV SMXII and VSD 115/230VAC, with or without elect. heat 8/9/05 BY: CE PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. 34
35 NPLTX Wire Colors BLK - L1 Power WHT/RED - L2/N ORG - Blower L1 BLUE - Valve L1 PUR - Heat L1 GRN - Ground L1 L2/N POWER PROPRIETARY NOTE: THE INFORMATION CONTAINED ENVIRONMENTAL. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC ENVIRONMENTAL SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. Note: NPLTX wire colors may not match the wire colors on the air handler. Follow the label on the air handler term. strip. BLWR2 * BLWR1 Air Handler #2 Junction Box (If Applicable) Plug CXP cable into SMXIR keypad/display mounted in cabin the OUT socket of the before this unit From board VALVE using SMXIIBB keypad (with 4-pin plug) use adapter # with CX cable, or use adapter #A-913 with CXP Cable. If CNP network cables must be daisy chained to each NPLTX box: the OUT cable to the IN of the next board BRN RED BLK the IN socket of the board after this unit To next CHANGE-OVER HEAT Outside TSEP Inside TSEP GND VLV1 BLWR1 L2/N (Purchased Separately) CXP## Connecting Cable HEAT1 (if installed) L2/N OUT Netwrk Netwrk IN L1 Power Input (115VAC or 230VAC) { Keypad CXP TSEP## Temperature Sensors (Purchased separately) Inside TSEP (.9m) wire harness 3' Outside TSEP HUMIDITY CONTROL Remove jumper and connect humidistat to HI PRESS tabs on P/L board GRN AUX WHT GND ACTION: Damp = Open Dry = Closed WHT LOW PUR (HEAT1) WHT/RD (L2) Wiring Instructions: WHT (COS) WHT (COS) BLUE (VLV1) ORG (BLWR1) HI Connect wire harness from P/L box to #1 air handler junction box 1. GND BLK (L1) WHT/RED Connect AC power and ground from electrical panel to #1 AH junct. box 2. N/L2 GRN BLK L1 POWER INPUT Plug inside TSEP cable to P/L box, and install sensor bulb in the return air path to the air handler 3. GATE EXT BLUE TER2 Plug outside TSEP cable to P/L box, and install sensor bulb in a shaded location (only 1 outside TSEP is needed if all units are networked together) 4. ORG V Plug in CXP cable at P/L box and the keypad/display 4. L1 L2/N BLWR2 BLWR1 VALVE HEAT BRN RED BLK POWER * CHANGE-OVER PUR BLK FAN P/L Board (A-282NT) YEL GATE Handler #1 Junction Box Air Up to 3 units can be installed on one control. additional units are installed, wire the valve, blower, and heat (if applicable) in parallel as shown. Maximum blower current is 6 amps. Maximum elect. heat current is 26 amps (3kW at 115V, 6kW at 230V) 5. PUR If TER2 Triac (A-548) F2 Do NOT remove L2/N jumper UNLESS a VSD fan speed control is installed * SMX Net Power/Logic Box NPLTX Field Wiring CRUISAIR Dometic Environmental DATE ISION DESCRIPTION APR Wiring Diagram - AT-COS Air Handler with NPLTX - SMX Net 115/230VAC, with or without elect. heat 8/26/05 BY: CE
36 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR A 8/11/05 ISED WIRE COLOR ON TERM#2,CAD DRR JES Dometic Environmental Corporation - Cruisair DATE: SCALE: 8/8/05 NTS BY: APR BY: LABEL, WIRING DIAGRAM AT6-36HV(Z) COS DRR JES PART NUMBER: C A 36
37 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORATION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Environmental Corporation - Cruisair DATE: SCALE: 8/8/05 NTS BY: APR BY: 37 LABEL, WIRING DIAGRAM AT4F(Z) COS DRR JES PART NUMBER: C O.I.
38 PROPRIETARY NOTE: THE INFORMATION CONTAINED CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE WITHOUT WRITTEN CONSENT FROM DOMETIC CORPORA- TION SHALL BE CONSIDERED UNLAWFUL AND CAN BE CONTESTED IN A COURT OF LAW. DATE ISION DESCRIPTION APR Dometic Environmental Corporation - Cruisair DATE: SCALE: 8/8/05 NTS BY: APR BY: 38 LABEL, WIRING DIAGRAM AT6-18F(Z) COS DRR JES PART NUMBER: C O.I.
39
40 Dometic Environmental Corporation 2000 N. Andrews Ave. Ext. Pompano Beach, FL USA Phone: Facsimile: Website: P.O. Box Richmond, VA USA Phone: Facsimile: Website: For Sales and Service Calls within Europe and the Middle East, please contact +44 (0) L-2295B
Air Handler Wiring Diagrams Abridged Version
Dometic Environmental Corporation Air Handler Wiring Diagrams Abridged Version L-2295A Revised: 5-24-07 Air Handler Wiring Diagrams - Table of Contents Page Drawing No. Description 4 H3010116 Elite-Passport
More informationUnity Board Micro Air Corporation Phone (609) Route Allentown NJ Fax (609)
Unity Board Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 January 11, 2016 1 Revision 1.02 Introduction The Unity board is a next generation
More informationHOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher
Micro Control Systems APPLICATION NOTE APP-006 5400-1 Division Drive Ft. Myers, FL 33905 USA (941)-694-0089 Fax (941) 694-0031 HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher Revision
More informationAH-Passport I/O (for CW systems)
AH-Passport I/O (for CW systems) OPERATIONS MANUAL AH-Passport I/O Compact AH-Passport I/O (legacy model) Dometic Marine Rev. 20090710 L-2232 English COPYRIGHT 2007-2009 Dometic Marine. All Rights Reserved.
More informationOTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems
OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:
More informationACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS
ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS For 13 SEER SJ, PAC R-22 Packaged Air Conditioners JP, PHP R-22 Packaged Heat Pumps NM, NL R-410A Packaged
More informationOT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems
OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:
More informationAH-Elite Control (for CW systems)
AH-Elite Control (for CW systems) OPERATIONS MANUAL Dometic Marine Rev. 20091102 L-2229 English COPYRIGHT 2007-2009 Dometic Marine. All Rights Reserved. No part of this publication may be reproduced, translated,
More informationmn Dometic Chilled Water Air Conditioning Marine Components Price List Manufacturer's Suggested Retail Prices (USD)
Chilled Water Air Conditioning mn Dometic 2175 NW 34th Ave Miami, FL 33142 USA Phone: 786-621-3010 Fax: 786-621-3046 Website: Email: info@yachtaidmarine.com Marine Components Price List Manufacturer's
More informationR-2000 HEADLINER Air Conditioner Unit
RED DOT UNITS ON ROAD R-2000 HEADLINER Air Conditioner Unit TRUCKS MOTOR HOMES VANS REFUSE The compact, low profile design of the R-2000 allows an out of the way ceiling mount in virtually any vehicle.
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More informationWiring Diagrams DIAGRAM INDEX
50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component
More informationDWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.1 December 2014
DWA2000 WAAS Annunciator Installation and Operations Manual Rev 1.1 December 2014 Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027 Tel: (615) 819-0800 Fax: (615) 819-0801 www.deklintech.com
More information10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual
INSTALLATION 10-175UL Power Supply 10-175UL Access Control Power Supply/Charger Installation and Specifications Manual Overview The 10-175UL is a power limited power supply/charger that will convert 115VAC
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK
More informationYour safety and the safety of others are very important.
VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3
More informationTSC & TSC-M Proofer/Oven
Illustrated Parts List BAKING CENTER BAKING CENTER TSC & TSC-M Proofer/Oven MODELS: TSC-6/8 TSC-6/8M TSC-/9 (Introduced February/009) TSC-/9M (Introduced January/0) This manual is Copyright 07 Duke Manufacturing
More informationPRODUCT GUIDE FOR LEISURE BOATS, WORKBOATS, AND COMMERCIAL AND MILITARY VESSELS
INSPIRED BY COMFORT MarineAir PRODUCT GUIDE FOR LEISURE BOATS, WORKBOATS, AND COMMERCIAL AND MILITARY VESSELS Includes Specification Sheets for: Direct Expansion and Chilled Water Air Conditioning, Controls,
More informationDSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE
DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1
More informationDH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil
DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED
More informationSchneider Electric Erie T155 Series
Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More informationParts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110
Parts Manual Gas Floor Type Convection Steamer Series: SteamCraft Model 24CGA10 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com
More informationMarine Components Price List Prices noted are US list prices.
Direct Expansion Chilled Water Air Conditioning Battery Chargers Refrigerator & Freezers Origo Stoves Refrigeration Grunert KRA Adler Barbour Eskimo Ice Marine Components Price List Prices noted are US
More informationImage Key Part Number Description Substitution Qty.
Model Number: BOM/Serial #: Graphic Title: XRSR465BW PXRSR465BW0 SUPPLEMENTAL INFORMATION Image Key Part Number Description Substitution Qty. 1 1 67002385 HARNESS-CONTROL 1 1 1 67002384 HARNESS, ICE MAKER
More informationTECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series
Fan Coils FVM4X B Series DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used
More informationShip-Wide Ventilation Systems
INSPIRED BY COMFORT Ship-Wide Ventilation Systems Protecting & Cooling Machinery Spaces for Leisure, Commercial & Military Vessels Specification Sheets for: Mist Eliminators, Blowers & Fans, Fire & Smoke
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationSINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES
wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5
More informationTECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS
TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents
More informationFactory Packaged Controls. MHGRV-X Controller Field Technical Guide
Factory Packaged Controls MHGRV-X Controller Field Technical Guide TABLE OF CONTENTS CONTROLLER OVERVIEW... 3 Features...3 INSTALLATION & WIRING... 4 Important Wiring Considerations...5 MHGRV-X Controller
More informationPDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual
INSTALLATION PDD-8PCI PDD-8PCI Power Distribution Board With Supervised Interface Installation and Specifications Manual Details The PDD-8PCI board is a power distribution/control interface. This board
More informationCAUTION! Before putting the boiler into operation read this manual carefully. WARNING!
CAUION! Before putting the boiler into operation read this manual carefully. WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss of life or property damage.
More informationDAP III Zone Master User s Guide
DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationFast Track Troubleshooting
Fast Track Troubleshooting Publication # tsrs265td Revision Date 03/30/2011 Models Covered: RS265TDBP/XAA RS265TDPN/XAA RS265TDRS/XAA RS265TDWP/XAA IMPORTANT SAFETY NOTICE For Technicians Only This service
More informationAVPTC. Air Handler 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in
More informationFast Track Troubleshooting
Fast Track Troubleshooting Models Covered: RS267TDBP/XAA RS267TDPN/XAA RS267TDRS/XAA RS267TDWP/XAA Publication # tsrs267td Revision Date 03/30/2011 IMPORTANT SAFETY NOTICE For Technicians Only This service
More informationvector compact Installation & Operation Direct Expansion Systems Revised: L-2254
vector compact Installation & Operation Direct Expansion Systems Revised: 20140321 L-2254 Table of Contents Table of Contents IF YOU HAVE A DIGITAL CONTROL...3 Introduction How It Works...4 Installation
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET:
-961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationEVO192 v3.0 Fire and Burglary What s New
EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION I - Ship ping and Pack ing List Pack age 1 of 1 con tains: INSTALLATION INSTRUCTIONS FOR ECONOMIZER USED WITH (B4,B5)SM 090/120 SERIES AIR HANDLER OUTDOOR FRESH AIR FORM # 572D-1210
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp
More informationD9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels
D9412GV2/D7412GV2 EN Approved Applications Compliance Guide Control Panels D9412GV2/D7412GV2 Approved Applications Compliance Guide Listings and Approvals Listings and Approvals Fire UL Underwriters Laboratories
More informationSeries. Access Power Controllers. Installation Guide
Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)
-961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect
More informationFast Track Troubleshooting
Models: DV431AEP DV431AEW DV431AGP DV431AGW NOTICE: 8/1/11 Parts changes see bulletins for serial breaks: motor, motor relay, wiring harness, & main PCB All Dryers Parts Change 6/2010: Motor Pulley, page
More informationGoodman Air Handler Wiring Diagram
GOODMAN AIR HANDLER WIRING DIAGRAM PDF - Are you looking for goodman air handler wiring diagram Books? Now, you will be happy that at this time goodman air handler wiring diagram PDF is available at our
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357
More informationParts Manual. Counter Type Gas Convection Steamer. Series: SteamCraft Model 21CGA East 179 th Street Cleveland, Ohio 44110
Parts Manual Counter Type Gas Convection Steamer Series: SteamCraft Model 21CGA5 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com
More informationINSTALLATION, OPERATION & QUICK START GUIDE
INSTALLATION, OPERATION & QUICK START GUIDE Controller CS9B-THOA CS9B-THOCA Models: CS9BE-THOA CS9BE-THOCA Bard Manufacturing Company, Inc. Bryan, Ohio 4506 www.bardhvac.com Manual: 00-684 Supersedes:
More informationTB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat
CD-TB200-01 TB-200 Product Battery Powered Thermostat Description The Evolve Wireless Digital Thermostat/Temperature Sensor is designed to control the majority of HVAC systems when used in conjunction
More informationWiring Diagrams Units Produced After April 20, 2009
UNIT 38AH 0-034 Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, 460-3-60 575-3-60 380-3-60-3-50, 380/415-3-50
More informationGSI Competitor & EMCS Portable Dryer Models
GSI Competitor & EMCS Portable Dryer Models Troubleshooting and Reference Manual 2004 Revised Edition PNEG-630 Competitor Series 2000 Dryer Table Of Contents Safety... 3 Safety Sign Off Sheet... 8 EMCS
More informationMcQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012
Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationNEW PRODUCTS SECTION P. 3-12
Specification Sheets for: Direct Expansion Air Conditioning Chilled Water Air Conditioning Controls & Accessories Eskimo Ice Fishbox Ice Systems NEW PRODUCTS SECTION P. 3-12 L-0002 LB-02 Rev. 20110930
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features
Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement
More informationSlow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.)
Tumbler turns ignition sparks no flame Gas supplymake sure gas supplyis working Gas pressure Make manometer check of gas pressure for 3.5" W.C. or more at supply side Spark electrode Gas valve Check electrode
More informationGreentrol Automation, Inc.
Model GA-100 Technical Manual GreenAlert 100 Series Greentrol Automation, Inc. Installation, Operation and Maintenance Technical Manual GA-100 Document Name: TM_GA-100_R1C TM_GA-100_R1C Part Number: 960--0000
More informationRPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev
RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationAVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...
More information/ How To Order
84-800 / 85-800 How To Order SERIES 84 = 1.0A continuous (powers and controls 1 EExER device with signal output for 1 operator) 85 = 2.0A continuous (powers and controls EExER device for 1 pair of doors
More informationModel 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions
Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8140 FRESH AIR ILATOR MODEL 8140NC FRESH AIR ILATOR FILTER COVER ILATION CONTROLLER FILTER COVER ILATION TERMINALS
More informationDVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV
DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationAllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax
AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The
More informationQuick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features
Installation Instructions E14QRG Issue Date June 28, 2018 Quick Reference Guide The Direct Spark Gas Ignition control module is designed for direct burner ignition and supervision. It can be used in new
More informationService and Maintenance Instructions
FB4, FE4, FF1E, FFM,FH4,FV4, FX4, FZ4, PF4 Residential Fan Coil Units Service and Maintenance Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE
More informationStatement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationpassport I/O controls
passport I/O controls Operation Manual DIRECT EXPANSION SYSTEMS Revised: 11-7-05 L-2231 Table of Contents 1.0 Passport I/O Controls Introduction 4 1.01 Standard Features... 4 1.02 Optional Features...
More informationFor a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.
Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight
More informationAVPTC Multi-Position, Internal Txv
Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration
More informationDirect Expansion & Tempered Water Air Conditioning
Direct Expansion & Tempered Water Air Conditioning mn Dometic 2175 NW 34th Ave Miami, FL 33142 USA Phone: 786-621-3010 Fax: 786-621-3046 Website: https://yachtaidmarine.com/product-category/marine-air-conditioners/
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationFor a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.
Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS CONTROLLER INSTALLATION, OPERATION & QUICK START GUIDE Bard CompleteStat TM CS9B-THO CS9B-THOC Models: CS9BE-THO CS9BE-THOC Bard Manufacturing Company, Inc. Bryan, Ohio 43506
More informationCompool. Cp3600 POOL-SPA CONTROL SYSTEM. Installation & Operating Instructions 02/10/
Compool Cp3600 POOL-SPA CONTROL SYSTEM Installation & Operating Instructions 02/10/98 941-1096 Compool Cp3600 1 Table of Contents Safety Notice............................................................
More informationGéothermal
Géothermal 2008-04-23 1375 Frank-Carrel, Local 14 Table of contents 1. General layout... 4 1.1. GÉOTHERMAL-IO Board... 4 1.2. Thermostat... 5 1.3. General Layout Zoning Board... 6 2. Connections... 7 3.
More informationRC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions
RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions DESCRIPTION The RC-90 is a precision digital thermostat designed for 24 VAC single stage heating and
More informationWater Source Heat Pump Module Technical Guide
Factory Packaged Controls Tulsa Water Source Heat Pump Module WSHP WSHP Protection Module Module Orion No.: OE334-23-WPM-A NON-DIGITAL COMPRESSORS #1 THRU #4 +5V SUCT. +5V SUCTION PR. SENSOR PRES PRES
More informationARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor
Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND
More informationModel 4880 Status Output Display Module Manual
Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical
More informationInstallation Instructions
Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationInstallation Instructions
Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More informationECM Blower, All Hookups, WarmFlo ST/OT CFM Selection
Assumptions Electro-HELPS VIII ECM Blower, All Hookups, WarmFlo ST/OT CFM Selection 1. Typically the furnace will be setup for a top (Y2) speed relating to cooling requirement. Installer must determine
More informationAIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.
wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC
More informationLX-100EZ EASYTOUCH POOL/SPA CONTROL SYSTEM INSTALLATION AND OWNERS MANUAL
LX-100EZ EASYTOUCH POOL/SPA CONTROL SYSTEM INSTALLATION AND OWNERS MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Important Notice Attention Installer. This
More informationMulti-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.
M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @
More informationSHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE
The Door Switch 11772 Westline Industrial Drive St. Louis, Mo 63146 (877) 998-5625 www.thedoorswitch.com Patent No. RE42,991 and RE44,039 CONTROL PANEL TRANSFORMER (SUPPLIED WITH CONTROL PANEL) NOTIFICATION
More informationLED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.
LED Driver Module Installation Guide 1.0 Notice These instructions are for installing Radionics LED Driver Module in a fire alarm system controlled by Radionics D8024 or D10024 Fire Alarm Control Panels