Vogt Tube - Ice machines P34AL

Size: px
Start display at page:

Download "Vogt Tube - Ice machines P34AL"

Transcription

1 Vogt Tube - Ice machines P34AL In 1938, Vogt Ice revolutionized the ice making industry by introducing the world s st automatic sized icemaker. Today, Vogt Tube-Ice machines enjoy as well-earned reputation as the most energy, dependable ice machines on the market. Heavy-duty industrial construction, automatic operation, and the best warranty in the business make the Vogt ice machines the only clear choice for your ice making needs. Three Ice Sizes Available: Cylinder (Tube-Ice) 7/8 Diameter X 1 long 1 1/8 Diameter X 1 long 1 3/8 Diameter X 1 long P34AL Features: 25 Year Life expectancy Up to 50 tons per day 25 Year evaporator warranty Manufactured in accordance with the A.S.M.E. code Ammonia Refrigerant Controls U.L. Approved Options: All Stainless Steel Construction PLC Controls Crushed Ice

2 10/1/2010 Tube-Ice Machines 6'-1" 6'-7" 3" FPT TANK OVERFLOW 4" SUCTION 3/4" FPT FLUSH 1" LIQUID 16'-0" 1" MAKE-UP 2" FPT TANK DRAIN 2 1/2" THAWING GAS ICE DISCHARGE 13" 24" 18" 25" 5'-6" LEFT VIEW 4'-6" FRONT VIEW 6'-10" RIGHT VIEW SPECIFICATIONS MODEL P34AL (Ammonia Refrigerant) TEMP. 80 o F 70 o F 60 o F 50 o F WEIGHT (LBS) STANDARD ELECTRICAL STANDARD CAPACITY, TONS PER 24 HOURS 7/8" DIA. ICE 1 1/8" DIA. ICE 1 3/8" DIA. ICE OPERATING: 11,070 OPERATING: 11,670 OPERATING: 11,670 SHIPPING: 9,400 SHIPPING: 10,000 SHIPPING: 10, V, 3P, 60 Hz - 460V, 3P, 60 Hz - 400V, 3P, 50 Hz (OPTIONAL ELECTRICAL ARRANGEMENTS ON REQUEST) CAPACITY TABLE, TONS PER 24 HOURS (AT SUCTION TEMPERATURE O F) TEMPERATURE 7/8" 1 1/8" 1 3/8" 7/8" 1 1/8" 1 3/8" 7/8" 1 1/8" 1 3/8" 7/8" 1 1/8" 1 3/8" 80 o F o F o F o F NOTE: STANDARD CAPACITY BASED ON SUCTION TEMPERATURE OF 10 O F AND AN AMBIENT (AIR) TEMPERATURE OF 90 O F Vogt reserves the right to change designs and specifications without notice. Operating Conditions: The ice machine shall not be subjected to an atmospheric temperature lower than 50 o F nor higher than 90 o F without effect on performance. Water for condensing and for ice making purposes shall be noncorrosive. The water shall be at a constant pressure not less than 30 lbs. at the ice machine location. The condition of the water to make satisfactory ice shall be the sesponsibility of the purchaser. Engineered to Endure Vogt Ice, LLC 1000 West Ormsby Ave., Louisville KY Phone: info@vogtice.com Revision 10/2010 (Printed in U.S.A.)

3 Vogt Tube - Ice machines P34AXL In 1938, Vogt Ice revolutionized the ice making industry by introducing the world s first automatic sized icemaker. Today, Vogt Tube-Ice machines enjoy as well-earned reputation as the most energy efficient, dependable ice machines on the market. Heavy-duty industrial construction, automatic operation, and the best warranty in the business make the Vogt ice machines the only clear choice for your ice making needs. Three Ice Sizes Available: Cylinder (Tube-Ice) 7/8 Diameter X 1 long 1 1/8 Diameter X 1 long 1 3/8 Diameter X 1 long P34XL Features: 25 Year Life expectancy Up to 110 tons per day 25 Year evaporator warranty Stainless Steel Water Pump with TEFC Motor Standard Stainless Steel Shell (on 1 and 1 1/4 Tube Units) Manufactured in accordance with the A.S.M.E. code Ammonia or R404a Refrigerant Controls U.L. Approved Factory Tested and Certified High Energy Efficiency Options: All Stainless Steel Construction PLC Controls Crushed Ice Available as Liquid Overfeed Remote Control Panel

4 u e- ce ac ne 10/1/2010 6'-9" MAX 4" SUCTION 1" LIQUID 19'-1"" MAX 3" FPT TANK OVERFLOW 2 1/2" THAWING GAS 3/4" FPT FLUSH 1 1/2" MAKE-UP ICE DISCHARGE 13" 24 1/4" 18" 25" 5'-6" LEFT VIEW 4'-6" FRONT VIEW RIGHT VIEW SPECIFICATIONS MODEL P34AL-15 (Ammonia Refrigerant) TEMP. 80 o F 70 o F 60 o F 50 o F WEIGHT (LBS) STANDARD ELECTRICAL CAPACITY TABLE, TONS PER 24 HOURS (AT SUCTION TEMPERATURE O F) TEMPERATURE 7/8" 1 1/8" 1 3/8" 7/8" 1 1/8" 1 3/8" 7/8" 1 1/8" 1 3/8" 7/8" 1 1/8" 1 3/8" 80 o F o F o F o F NOTE: STANDARD CAPACITY BASED ON SUCTION TEMPERATURE OF 10 O F AND AN AMBIENT (AIR) TEMPERATURE OF 90 O F Vogt reserves the right to change designs and specifications without notice. Operating Conditions: The ice machine shall not be subjected to an atmospheric temperature lower than 50 o F nor higher than 90 o F without effect on performance. Water for condensing and for ice making purposes shall be noncorrosive. The water shall be at a constant pressure not less than 30 lbs. at the ice machine location. The condition of the water to make satisfactory ice shall be the sesponsibility of the purchaser. 7/8" DIA. ICE OPERATING: 15,400 SHIPPING: 11,700 STANDARD CAPACITY, TONS PER 24 HOURS 1 1/8" DIA. ICE OPERATING: 16,200 SHIPPING: 12, V, 3P, 60 Hz - 460V, 3P, 60 Hz - 400V, 3P, 50 Hz (OPTIONAL ELECTRICAL ARRANGEMENTS ON REQUEST) Engineered to Endure Vogt Ice, LLC 1000 West Ormsby Ave., Louisville KY Phone: info@vogtice.com 1 3/8" DIA. ICE OPERATING: 16,100 SHIPPING: 12,000 Revision 10/2010 (Printed in U.S.A.)

5 Vogt Tube - Ice machines P34A-P34F In 1938, Vogt Ice revolutionized the ice making industry by introducing the world s first automatic sized icemaker. Today, Vogt Tube-Ice machines enjoy as well-earned reputation as the most energy efficient, dependable ice machines on the market. Heavy-duty industrial construction, automatic operation, and the best warranty in the business make the Vogt ice machines the only clear choice for your ice making needs. Three Ice Sizes Available: Cylinder (Tube-Ice) 7/8 Diameter X 1 long 1 1/8 Diameter X 1 long 1 3/8 Diameter X 1 long P34 Features: 25 Year Life expectancy Up to 50 tons per day Self Contained Packaged Unit 25 Year evaporator warranty Stainless Steel Water Pump with TEFC Motor Manufactured in accordance with the A.S.M.E. code R404a or Ammonia Refrigerant Controls U.L. Approved Factory Tested and Certified High Energy Efficiency Options: All Stainless Steel Construction PLC Controls Crushed Ice

6 Tube-Ice Machines 10/1/2010 9'-1" 5" CONDENSER OUTLET 5" CONDENSER INLET 16'-0" 3" TANK OVERFLOW 3/4" FLUSH ICE DISCHARGE 13" 1" MAKE-UP 2" DRAIN 25 18" 8'-6" 7'-9" LEFT VIEW FRONT VIEW RIGHT VIEW SPECIFICATIONS MODEL P34A (Ammonia Refrigerant) MODEL P34F (R-404a Refrigerant) TEMPERATURE 80 o F 70 o F 60 o F 50 o F STANDARD CAPACITY, TONS PER 24 HOURS 7/8" DIA. ICE 1 1/8" DIA. ICE 1 3/8" DIA. ICE 7/8" DIA. ICE 1 1/8" DIA. ICE 1 3/8" DIA. ICE OPERATING: 24,000 SHIPPING: 20,500 OPERATING: 24,500 SHIPPING: 21,000 OPERATING: 24,500 SHIPPING: 21,000 OPERATING: 25,500 SHIPPING: 22,000 OPERATING: 26,000 SHIPPING: 22,500 WEIGHT (LBS) STANDARD POWER: 460V, 3P, 60 Hz CONTROLS: 230 V, 1P, 60 Hz ELECTRICAL (OPTIONAL ELECTRICAL ARRANGEMENTS ON REQUEST) Vogt reserves the right to change designs and specifications without notice. OPERATING: 26,000 SHIPPING: 22,500 Operating Conditions: The ice machine shall not be subjected to an atmospheric temperature lower than 50 o F nor higher than 90 o F without effect on performance. Water for condensing and for ice making purposes shall be noncorrosive. The water shall be at a constant pressure not less than 30 lbs. at the ice machine location. The condition of the water to make satisfactory ice shall be the sesponsibility of the purchaser. Engineered to Endure Vogt Ice, LLC 1000 West Ormsby Ave., Louisville KY Phone: info@vogtice.com Revision 10/2010 (Printed in U.S.A.)

Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube-Ice Machines

Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube-Ice Machines Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube- Machines Standard Construction: All surfaces in contact with water or ice are of stainless steel or other rust resistant material. External

More information

Turbo Chiller Now in Stock "Click Here" for details. (1 of 2)8/12/ :01:18 AM

Turbo Chiller Now in Stock Click Here for details.  (1 of 2)8/12/ :01:18 AM http://vogtice.com/ Turbo Chiller Now in Stock "Click Here" for details. http://vogtice.com/ (1 of 2)8/12/2003 11:01:18 AM Vogt History Vogt revolutionized the commercial ice-making industry in 1937 when

More information

FIRST IN RELIABILITY FIRST IN CHOICE

FIRST IN RELIABILITY FIRST IN CHOICE FIRST IN RELIABILITY FIRST IN CHOICE PISTON COMPRESSOR TUBE ICE MACHINE VALVES SPARE PARTS AMMONIA PUMP TURNKEY PROJECTS A HISTORY OF EXCELLENCE Established in 21, Metalex has grown to become a leading

More information

Installation Instructions

Installation Instructions Installation Instructions B-Series VT40, VT60, VT100 Important Safety Notice. This information is intended for use by individuals possessing adequate backgrounds of electrical, refrigeration and mechanical

More information

P-24A & P-34A TUBE-ICE MACHINE

P-24A & P-34A TUBE-ICE MACHINE P-24A & P-34A TUBE-ICE MACHINE Service Manual $50 00 12/20/12 NOTICE This manual is the property of the owner of this particular Tube-Ice machine. Model # Serial #. It is to be left on the premises with

More information

MHG-LR MODULAR TURBO REFRIGERATING ICE MACHINE

MHG-LR MODULAR TURBO REFRIGERATING ICE MACHINE MHG-LR MODULAR TURBO REFRIGERATING ICE MACHINE Manual Part Number 12A4171M12 Service Manual $50 00 8/28/00 NOTICE This manual is the property of the owner of this particular Tube-Ice machine. Model # Serial

More information

Compressors, Chillers & Condensers

Compressors, Chillers & Condensers Totaline s water-cooled condensers are designed for a wide range of applications and are available in many models ranging from 5 to 400 nominal tons. Small and large condensers are available for fresh

More information

MHG A FL MODULAR. Manual Part Number 12A4171M11. Service Manual $50.00 USD

MHG A FL MODULAR. Manual Part Number 12A4171M11. Service Manual $50.00 USD MHG A FL MODULAR Manual Part Number 12A4171M11 Service Manual $50.00 USD This page intentionally left blank well sort of. NOTICE This manual is the property of the owner of this particular Tube-Ice machine.

More information

05TA TUBE-ICE MACHINE

05TA TUBE-ICE MACHINE 05TA TUBE-ICE MACHINE (Includes model P118F/HE100) Manual Part Number 12A4171M06 Revision 3 Service Manual $50 00 NOTICE This manual is the property of the owner of this particular Tube-Ice machine. Model

More information

10TA TUBE-ICE MACHINE

10TA TUBE-ICE MACHINE 10TA TUBE-ICE MACHINE (Includes model P18FXT) Manual Part Number 12A4171M08 Revision 3 Service Manual $50 00 NOTICE This manual is the property of the owner of this particular Tube-Ice machine. Model #

More information

TURBO Refrigerating HTD and HF Chillers

TURBO Refrigerating HTD and HF Chillers TURBO Refrigerating HTD and HF Chillers Manual Part Number 12A4171M15 Service Manual $50 00 USD NOTICE This manual is the property of the owner of this particular Vogt Ice, LLC machine. Model # Serial

More information

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants Phillips REFRIGERATION MECHANICAL PUMP RECIRCULATORS BULLETIN MPR-03E Engineering Data VALVES VESSELS SYSTEMS CONTROLS HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

More information

P-34F TUBE-ICE MACHINE

P-34F TUBE-ICE MACHINE P-34F TUBE-ICE MACHINE Service Manual $50 00 1/11/06 P34F Service Manual 1-1 INTRODUCTION 1. Introduction Tube-Ice LLC A Brief History Of Our Company. In 1938, Vogt built the first Tube-Ice machine and

More information

HE S Series TUBE-ICE MACHINE INSTALLATION & START-UP INSTRUCTIONS. Part Number: 12A4171S0702

HE S Series TUBE-ICE MACHINE INSTALLATION & START-UP INSTRUCTIONS. Part Number: 12A4171S0702 HE S Series TUBE-ICE MACHINE INSTALLATION & START-UP INSTRUCTIONS Part Number: 12A4171S0702 5/2/2011 Blank Page 2 Revision Date: April 2011 Table of Contents Bin Installation -----------------------------------------------------------

More information

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice

More information

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Coil-In-Tank Design: Refrigeration System: Cabinet Construction: Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key

More information

HE S Series TUBE-ICE MACHINE. Service Manual $50 00

HE S Series TUBE-ICE MACHINE. Service Manual $50 00 HE S Series TUBE-ICE MACHINE Service Manual $50 00 NOTICE This manual is the property of the owner of this particular Tube-Ice machine. Model # Serial #. It is to be left on the premises with this machine

More information

SELF-CONTAINED FLAKER

SELF-CONTAINED FLAKER Reliability is a beautiful thing TM SELF-CONTAINED FLAKER F-500BAF(-C) INSTRUCTION MANUAL ISSUED: April 13, 1998 REVISED: December 30, 2004 IMPORTANT Only qualified service technicians should attempt to

More information

Refrigeration System Overview. ASTI 32 Hour Managing Ammonia Course September 27 30, 2016

Refrigeration System Overview. ASTI 32 Hour Managing Ammonia Course September 27 30, 2016 Refrigeration System Overview ASTI 32 Hour Managing Ammonia Course September 27 30, 2016 A refrigeration system is a mechanical heat transport system. The system absorbs heat energy from an area it is

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

Glass Doors, Hinged Bottom Mounts

Glass Doors, Hinged Bottom Mounts Product Specification Sheets Construction Standard Features Interior and exterior constructed of heavyduty white coated steel CFC free foamed-in-place polyurethane insulation Stainless steel floor Externally

More information

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98 Air-Cooled Condenser Installation Instructions Revision Date: 12/21/98 ! WARNING! These installation guidelines must be followed to obtain reliable operation from air-cooled ice machines. If these guidelines

More information

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost. LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

Falling Film Chiller. water down to 0,5 C

Falling Film Chiller. water down to 0,5 C Falling Film Chiller BUCOdelot water down to 0,5 C Application fields Industrial chilling of food fish, meet, poultryl fruit, vegetables milk, milk products softdrink production production of baked goods

More information

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice

More information

Air-Cooled Condensers

Air-Cooled Condensers CH-RACCTB APR 2015 Replaces CH-RACCTB April 2011 Air-Cooled Condensers Technical Guide Models WSS Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional Data...5

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C)

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C) NO: 73099 ISSUED: AUG. 29, 2001 REVISED: DEC. 16, 2003 HOSHIZAKI MODULAR FLAKER MODEL F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C) SERVICE MANUAL IMPORTANT Only qualified service technicians

More information

Fan speed controller Type Saginomiya XGE

Fan speed controller Type Saginomiya XGE Data sheet Fan speed controller Type Saginomiya Fan speed controller stabilizes condensing pressure by changing condenser s fan speed. The controller reduces fan noise and saves energy in low ambient conditions.

More information

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online.

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online. Order parts online www.follettice.com D400A/W Ice Machine Installation Manual D400A ice machine D400W ice machine 801 Church Lane Easton, PA 18040, USA Toll free (877) 612-5086 (610) 252-7301 www.follettice.com

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Modular Flaker Models F-2000MWH(-C) F-2000MRH(-C) F-2000MRH3(-C) F-2000MLH(-C) A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73116 Issued: 7-16-2004

More information

(2) 325 tpd York Chlorine Liquefier Systems

(2) 325 tpd York Chlorine Liquefier Systems (2) 325 tpd York Chlorine Liquefier Systems The liquefier is a split bundle and serves as both the primary liquefier and the secondary liquefier. The total for each York system is 325 tons liquid Cl2,

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

Reach In Refrigerators Bottom Mount

Reach In Refrigerators Bottom Mount Reach In Refrigerators Bottom Mount Product Specification Sheets Construction Standard Features Stainless Steel Doors Heavy duty hinge with self closing mechanism Exterior galvanized pre-painted steel

More information

Installation Instructions. Revision Date: 05/16/12

Installation Instructions. Revision Date: 05/16/12 Air-Cooled Condenser Installation Instructions Revision Date: 05/16/12 ! WARNING! These installation guidelines must be followed to obtain reliable operation from air-cooled ice machines. If these guidelines

More information

Maestro Plus. Features. self-contained 425 series Chewblet RIDE ice machine

Maestro Plus. Features. self-contained 425 series Chewblet RIDE ice machine Maestro Plus self-contained 425 series Chewblet RIDE ice machine Maestro Plus 425 series ice machine, 115V/60 Hz Install/ For use with 1 mount Condenser V/Hz/Ph Item number ice storage bin Follett Vision

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm Refrigerated Dryers Cycling; Non-Cycling; High Pressure; High Temperature 20 30,000 scfm The Importance of Clean, Dry Compressed Air How much water is too much? Any amount of water is too much. Water jeopardizes

More information

Global Series Screw Air Compressors Life source of industries

Global Series Screw Air Compressors Life source of industries Global Series Screw Air Compressors Life source of industries 125-200 HP series Global Series Elgi, established in 1960, designs and manufactures a wide range of compressors. The company has gained its

More information

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer Here shown with Tetra Pak Volumetric Bottom Filler Highlights Increased efficiency with servo controlled mould table index, extractor functions

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1601SAH/3 KM-1601SWH/3 KM-1601SRH/3 A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73145 Issued: 10-31-2006 Revised:

More information

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer Here shown with Tetra Pak Volumetric Bottom Filler Highlights Operating principle Increased efficiency with servo controlled mould table index,

More information

INSTANT CHILLER. Chester-Jensen Co., Inc. Unit Construction and Short Gas Flow

INSTANT CHILLER. Chester-Jensen Co., Inc. Unit Construction and Short Gas Flow Chester-Jensen Co., Inc. INSTANT CHILLER COOLANT RETURN FROM PROCESS Chilling water instantly and continuously to 33ºF presents no problem to the user of a Chester-Jensen Chiller. Other liquids, brine,

More information

pdfmachine trial version

pdfmachine trial version HVAC PROBLEM SHEET # 02(REVERSED BRAYTON CYCLE) 1. 500 kg of atmospheric air is circulated per hour in an open type of refrigeration installation. The air is drawn from the cold chamber at temperature

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the

More information

investment in R&D, the commitment to - name.

investment in R&D, the commitment to - name. The Hillphoenix name is synonymous with innovative, sustainable and extremely efficient refrigeration systems in a variety of business segments. While much of the company s reputation has been built as

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

PIONEERS OF TRAILER REFRIGERATION IN THE UNITED STATES

PIONEERS OF TRAILER REFRIGERATION IN THE UNITED STATES PIONEERS OF TRAILER REFRIGERATION IN THE UNITED STATES A COOL IDEA GOES AROUND THE WORLD 2 Sometimes a simple but cool idea can make its way from a small town in Germany to the biggest cities of the United

More information

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors. LK-TSSTB July 2009 FPO 5-30 HP Two Stage Condensing Units and Systems Technical Guide with Bitzer s www.larkinproducts.com Table of Contents Standard Features... 2 Nomenclature... 2 Condensing Unit Capacity...

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Fast Track Troubleshooting Models Covered: RF197ACPN French Door Refrigeration IMPORTANT SAFETY NOTICE For Technicians Only This service data sheet is intended for use by persons having electrical, electronic,

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Air cooled industrial chillers

Air cooled industrial chillers Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage

More information

SELF-CONTAINED CRESCENT CUBER

SELF-CONTAINED CRESCENT CUBER Reliability is a beautiful thing TM SELF-CONTAINED CRESCENT CUBER KM-250BAF KM-250BWF INSTRUCTION MANUAL ISSUED: March 14, 2000 REVISED: December 22, 2004 IMPORTANT Only qualified service technicians should

More information

Deaerator. Specifications

Deaerator. Specifications ESI, INC. OF TENNESSEE RENTAL EQUIPMENT Deaerator Description The deaerator, built in 1996, is a spray-type deaerating feedwater heater and storage tank with stainless steel internals. The deaerator is

More information

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Evaporators. Direct Expansion Flooded Recirculated Over Feed Evaporators Purpose: Liquid Refrigerant is Boiled from a Low Pressure Liquid to a Low Pressure Gas by Absorbing Heat from the Medium that is being Cooled Types: Direct Expansion Flooded Recirculated Over

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

OACS Outdoor Air-Cooled Central Chillers

OACS Outdoor Air-Cooled Central Chillers OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single

More information

RSG16**S1M. Split System Air Conditioner 16 SEER

RSG16**S1M. Split System Air Conditioner 16 SEER RSG16**S1M Split System Air Conditioner 16 SEER COMPRESSOR High-efficiency 2 stage Copeland UltraTechTM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG: Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1900SAH/3 KM-1900SWH/3 KM-1900SRH/3 A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73171 Issued: 2-9-2009 Revised:

More information

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL NO.: 73067 ISSUED: JUNE 23, 1998 REVISED: DEC. 15, 2003 HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service or maintain

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

DROP-IN + PLUG-IN UNITS

DROP-IN + PLUG-IN UNITS DROP-IN + PLUG-IN UNITS Suppliers to the air-conditioning, heating and refrigeration trade. www.totaline.com.au 111 EIDIS Refrigeration Drop-in Packaged Refrigeration Units Drop-In Units Slide-In Units

More information

Air-Cooled Condensers

Air-Cooled Condensers BN-RACCTB Sept. 2016 Replaces BN-RACCTB April 2015 Air-Cooled Condensers Technical Guide Models DVT Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

MODULAR CRESCENT CUBER

MODULAR CRESCENT CUBER Reliability is a beautiful thing TM MODULAR CRESCENT CUBER KMD-700MAH KMD-700MWH KMD-700MRH KMD-900MAH KMD-900MWH KMD-900MRH INSTRUCTION MANUAL ISSUED: APRIL 24, 2003 REVISED: JAN. 3, 2008 IMPORTANT Only

More information

Freezer Catalog. Shop Online: Sure Marine Service, Inc th Ave. N.W. Seattle, WA (800) (206)

Freezer Catalog. Shop Online:   Sure Marine Service, Inc th Ave. N.W. Seattle, WA (800) (206) Freezer Catalog Sure Marine Service, Inc. 5320 28th Ave. N.W. Seattle, WA 98107 (800) 562-7797 (206) 784-9903 Shop Online: www.suremarineservice.com CRUISE Classic and Stainless Steel Marine Freezers New

More information

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor... This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM9 SERVICE PARTS TABLE OF CONTENTS

More information

Suction Accumulators. Introduction. Suction Accumulators

Suction Accumulators. Introduction. Suction Accumulators Introduction The purpose of the Suction Accumulator is to provide temporary storage for any liquid refrigerant and oil that is returning to the compressor from the evaporator. The accumulator s internal

More information

FLAKER/DCM SEQUENCE OF OPERATION

FLAKER/DCM SEQUENCE OF OPERATION FLAKER/DCM SEQUENCE OF OPERATION H O S H I Z A K I A M E R I C A The Flaker and DCM series of ice machines use a completely different ice making process than the cuber style of icemaker. The Flaker has

More information

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...

More information

Refrigeration Supplies

Refrigeration Supplies Section 11 Refrigeration Supplies INDEX Refrigerant.. 11-2 R-410A. 11-2 HOT-SHOT by ICOR.. 11-2 NU-22b by ICOR. 11-2 Recovery Service 11-2 Recovery Tanks. 11-2 608 Certification. 11-2 Supplies Filter Driers.

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Self-Contained Cubelet Models C-100BAF C-100BAF-DS C-100BAF-AD C-100BAF-ADDS A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73180 Issued: 10-6-2010 Revised:

More information

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL ISSUED: FEB. 28, 2001 REVISED: DEC. 11, 2003 IMPORTANT Only qualified service technicians should attempt

More information

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants Unit Objectives After studying this chapter, you should be able to: Discuss applications for high-, medium-, and low temperature refrigeration.

More information

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual 1 of 5 4/7/2008 8:32 AM Home Account Contact ALLDATA Log Out Help Select Vehicle New TSBs Technician's Reference Component Search: METRO TOYOTA OK 1999 Ford Truck F 450 2WD Super Duty V10-6.8L VIN S Vehicle

More information

Refrigerant Valves/Accessories

Refrigerant Valves/Accessories Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating

More information

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C) ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C) INSTRUCTION MANUAL FOREWORD IMPORTANT Only qualified service technicians should attempt to install, service or maintain

More information

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division Introduction of Panasonic CO2 refrigeration system Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division Compressor New Model Outdoor Small Size CO2 Refrigeration Unit CO2

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1800SAH/3 KM-1800SWH/3 KM-1800SRH/3 A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73131 Issued: 11-11-2005 Revised:

More information

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL SPECIFICATIONS B6VMMX TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers

More information

Technical Bulletin (TB )

Technical Bulletin (TB ) This document serves as a guideline when using refrigerants R407A and R407F in low temperature application with BITZER ECOLINE semi-hermetic reciprocating compressors. Topics covered: 1. Overview 2. CIC

More information

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank A C P S C STACT Model Designations Model Number: STACT8S6 ST AC T ST = Portable Scroll Chiller AC = Air Cooled WC = Water Cooled T = With Process Tank 8 8 = Model Size* S 6 XP / LT S = Single Refrigeration

More information

KM-630MAH KM-630MWH KM-630MRH

KM-630MAH KM-630MWH KM-630MRH NO.: ISSUED: 73114 JUNE 23, 2004 HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-630MAH KM-630MWH KM-630MRH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service or maintain this

More information