MULTI. MPS Variable Multi System(50Hz, R22) Tropical, Free Joint LM F4. P/No.: 3828A20428P. Replaces: LM F3

Size: px
Start display at page:

Download "MULTI. MPS Variable Multi System(50Hz, R22) Tropical, Free Joint LM F4. P/No.: 3828A20428P. Replaces: LM F3"

Transcription

1 MULTI MPS Variable Multi System(50Hz, R22) Tropical, Free Joint Approvals: ST IR M EN ISO 9001 F S O E R E D A8 For continual product development, LG reserves the right to change specifications without notice LG Electronics INC. Printed in Korea. November/2004 BS EN ISO 9001 ANSI/ASQC Q TYPE APPROVED ctronics Ele In I REG I P/No.: 3828A20428P TÜV Rheinland Product Safety G c. BAUART GEPRÜFT L 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul , Korea Phone : Fax: /8 KS A 9001 LM F4 Replaces: LM F3

2 General Description Thank you very much for your special patronage of LG products. A high-grade, high-quality, advanced individual air-conditioning system that is able to respond to expanding, more sophisticated housing environment needs. Large size indoor units are required for coping with the large space like the condominiums or the big houses where systems are used at present. Besides, there are needs to provide the room air conditioners owing to the sophisticated interior and small rooms. On the background of these needs, the new multi outdoor unit, which can connect both the residential indoor units and the light commercial indoor units, has been developed. LG Electronics Inc., has developed "MPS(Multi Power System) Variable Multi" system that can efficiently control air-conditioning ensuring a better environment. A lot of information regarding the design and the installation of "MPS Variable Multi" system is included in this publication. We hope that with this information you would become an expert of the "MPS Variable Multi" system and be more comprehensive to the system. LG Electronics Inc. Air Conditioning Division 2004 Product Data 1

3 2 MPS(Multi Power System) Variable Multi

4 LG Airconditioners Product Data TABLE OF CONTENTS Table of contents Page Part 1 General Information Model Names Model Number Nomenclature Outline of System Features Control System...24 Part 2 Indoor Units Wall Mounted Ceiling Cassette 4-way Ceiling Concealed Duct - High Static Pressure Ceiling Concealed Duct - Low Static Pressure...79 Part 3 Outdoor Units...93 Part 4 Control Basic Control Devices and Function Central Control Part 5 Installation Refrigerant piping System Electrical Wiring Drain Pipe Work Product Data 3

5 4 MPS(Multi Power System) Variable Multi

6 Part 1 General Information 1. Models Name Indoor Units Outdoor Units Model Number Nomenclature Indoor Unit Outdoor Unit Outline of System Example of System Connectability Matrix for Indoor and Outdoor units External Apperance Features Outdoor Units BD Units Indoor Units Control System Various Central Control Control Device Product Data 5

7 1. Models Name 1.1 Indoor Units Wall Mounted Ceiling Cassette Ceiling Concealed Duct Category General 4Way High Static Low Static Chasiss SR ST TE TF TD BH BG BE BT 3.5 (12000) LMNH/C 126LRL0 - LMNH/C 126TEC0 Model Name Capacity, kw(btu/h) LMNH/C 186LTL0 LMNH/C 186TEC0 - - LMNH/C 246LTL LMNH/C 246TFC0 LMNH/C 306TFC LMNH/C 186BHA0 LMNH/C 246BHA LMNH/C 366TDC0 LMNH/C 486TDC LMNH/C 306BGA0 LMNH/C 366BGA LMNH/C 126BTG0 5.3 (18000) LMNH/C 186BTG0 7.0 (24000) 8.8 (30000) 10.6 (36000) 14.1 (48000) - LMNH/C 486BEA Outdoor Units MPS Variable Multi Cooling Only Heat Pump Model Name L4UC608FA0 L5UC728FA0 L8UC1008FA0 L8UH1008FA0 Rated Capacity Cooling Btu/h Heating Btu/h Number of Indoor Units to be Connected Max.4 Units Max.5 Units Max.8 Units Max.8 Units Total Capacity of Indoor Units Connected Btu/h 12,000~60,000 12,000~78,000 12,000~108,000 12,000~108,000 Power Supply 3Ø, V, 50Hz BD(Branch Distributon) Unit PMBD5420L PMBD5430L PMBD5440L Number of Indoor Units to be Connected Max. 2 Units Max. 3 Units Max. 4 Units Combination (Min. ~Max.) 12,000~54,000 Btu/h Capacity of Connectable kw 3.5/5.3/7.0/8.8/10.6 Indoor units Btu/h 12k/18k/24k/30k/36k 6 MPS(Multi Power System) Variable Multi

8 2. Model Number Nomenclature 2.1 Indoor Unit LMN H 12 6 L R L 0 Serial Number Function A : Basic, L : Nano Plasma (Wall Mounted) C: Plasma(Ceiling Cassette) G: Low Static ART COOL(Mirror) Type Front Panel Color B: Blue, D: Wood, M: Metal, R: Mirror, W: White Chassis Name Indoor Unit Type L : Wall Mounted T : Ceiling Cassette A : ART COOL B : Ceiling Concealed Duct D : ART COOL Mirror Electrical Rating 6 : 1Ø, V, 50Hz Nominal Cooling Capacity in Btu/h Ex) 12,000 Btu/h '12', 48,000 Btu/h '48' Model Type H : Heat Pump C : Cooling Only 2.2 Outdoor Unit MPS Variable Multi System Indoor Unit L8U H F A 0 Serial Number Function A : Basic Multi Type F : Free Joint Multi Type Electrical Ratings 8 : 3Ø, V, 50Hz Nominal Cooling Capacity in Btu/h Ex) 100,000 Btu/h '100' Model Type H : Heat Pump C : Cooling Only R22 MPS Variable Multi System Outdoor Unit. And No. of Connectable Indoor Units Ex) L8U : Connectable max. 8 Indoor Units 2004 Product Data 7

9 3. Outline of System Unlike traditional multi-type units, it is a next-generation multi type air-conditioner designed to be installed under any circumstrance, combining with wall-mounted, ceiling-mounted units. 3.1 Example of System L4UC608FA0 Multi System Circuit 1 can be connected up to max. 3 indoor units. When installing single 36,000 Btu/h indoor unit for circuit 1, use the short tube connector(not branch distributor unit). Circuit 2 can be only connected up single 24,000 Btu/h indoor unit. Case 1 [Indoor Unit] BD(Branch Distributor) Unit [12,000 Btu/h] [12,000 Btu/h] [Outdoor Unit] Circuit 1 [12,000 Btu/h] [24,000 Btu/h] Circuit 2 Case 2 [Indoor Unit] Short tube connector (Accessory) [36,000 Btu/h] [Outdoor Unit] Circuit 1 [24,000 Btu/h] Circuit 2 8 MPS(Multi Power System) Variable Multi

10 3. Outline of System L5UC728FA0 Multi System Circuit 1 can be connected up to max. 4 indoor units. When installing single 48,000 Btu/h indoor unit for circuit 1, use the short tube connector(not branch distributor unit). Circuit 2 can be only connected up single 24,000 Btu/h indoor unit. Case 1 [Indoor Unit] BD(Branch Distributor) Unit [12,000 Btu/h] [12,000 Btu/h] [12,000 Btu/h] [Outdoor Unit] Circuit 1 [12,000 Btu/h] [24,000 Btu/h] Circuit 2 Case 2 [Indoor Unit] Short tube connector (Accessory) [48,000 Btu/h] [Outdoor Unit] Circuit 1 [24,000 Btu/h] Circuit Product Data 9

11 3. Outline of System L8UC/H1008FA0 Multi System Both circuit 1 and circuit 2 can be connected up to max. 4 indoor units. When installing single 48,000 Btu/h indoor unit for each circuit, use the short tube connector(not branch distributor unit). Case 1 [Indoor Unit] Short tube connector (Accessory) Circuit 1 [48,000 Btu/h] [Outdoor Unit] [48,000 Btu/h] Circuit 2 Case 2 [Indoor Unit] BD(Branch Distributor) Unit [12,000 Btu/h] [12,000 Btu/h] [12,000 Btu/h] Circuit 1 [12,000 Btu/h] [Outdoor Unit] [12,000 Btu/h] [12,000 Btu/h] [12,000 Btu/h] Circuit 2 [12,000 Btu/h] 10 MPS(Multi Power System) Variable Multi

12 3. Outline of System 3.2 Connectability Matrix for Indoor and Outdoor units Indoor Units Outdoor Units L4UC608FA0 L5UC728FA0 L8UC1008FA0 L8UH1008FA0 Model Type Capacity Number of connectible Indoor Units Index Btu/h kw up to 4 up to 5 up to 8 up to O O O O Wall Mounted O O O O O O O O O O O O 4 Way O O O O O O O O O O O O O O O O High Static O O O O O O O O O O Low O O Static O O Ceiling Cassette Ceiling Concealed Duct Note : 1. See the chapter 3 combination table of "Part 3 Outdoor Units" for possible combinations of indoor units. 2. The total capacity index of indoor units is the sum of capacity index of each units and should be within the maximum capacity index of the outdoor unit Product Data 11

13 3. Outline of System 3.3 External Apperance Outdoor Units BD Unit (Branch Distributor Unit) -Accessory L4UC608FA0 L5UC728FA0 L8UC1008FA0 L8UH1008FA0 PMBD5420L PMBD5430L PMBD5440L Indoor Units Wall Mounted Ceiling Mounted Cassette 4 way LMNH/C126LRL0 LMNH/C186LTL0 LMNH/C246LTL0 LMNH/C126TEC0 LMNH/C186TEC0 LMNH/C246TFC0 LMNH/C306TFC0 LMNH/C366TDC0 LMNH/C486TDC0 Ceiling Concealed Duct High Static Ceiling Concealed Duct - Low Static LMNH/C186BHA0 LMNH/C246BHA0 LMNH/C306BGA0 LMNH/C366BGA0 LMNH/C486BEA0 LMNH/C126BTG0 LMNH/C186BTG0 12 MPS(Multi Power System) Variable Multi

14 4. Features 4.1 Outdoor Unit L4UC608FA0 L5UC728FA0 L8UC1008FA0 L8UH1008FA0 MPS Variable System - High Efficiency - Low Noise - High Reliability Can be Combined with Various Indoor Units Max. Total 120 meters Piping Length(100k model) Available to Max.8 Indoor Units by Simple Piping Powerful Cooling & Heating Capacity Low Operation Sound Central Control Easy Installation Low Electric Fee MPS(Multi Power System) Variable Control : Big Energy Saving with MPS Control Basic Principle of MPS Control MPS control provides comfortable and convenient environment as there are two compressors with 60&40% load sharing with on compressor of small capacity always working to maintain the set temperature conditions & meanwhile other compressor is at rest if the load is low whereas in conventional system the only compressor is working with ON/OFF cycles. Conventional (On/Off Operation) MPS Control 100% 40% 60% Power Consumption Comparison MPS Variable Multi system opeates in one cycle with two compressors. Only one compressor or two compressors run together, according to the load conditions. With small load. only one compressor completes the cycle. It saves power consumption at low operation. This concept is explained in the picture below. Conventional (On/Off Operation) MPS 100% Cooling Capacity Power Loss Zone Cooling Load Max. 35% Energy Saving 100% Cooling Capacity Saving Zone 40% 60% 100% Cooling Load Operating Ratio Operating Ratio 2004 Product Data 13

15 4. Features Various Multi Connecting : (100k size shown) 2Room Type Both 1Room Type and Distributor Type Distributor Type Flexible Design and Simple Piping - Distributor Type For 2 Indoor Units For 3 Indoor Units For 4 Indoor Units Various BD unit for flexible design Available up to max.8 indoor units by simple piping Connecting to the BD unit without Brazing Indoor unit tubing Flare nut Pipes Open-end wrench (fixed) Flare nut Wrench Connection pipe Central Control : Centralized Controller First, We have a simple central controller that can operate up to 16 units simultaneously. PC Based Controller And especially, with an intuitively designed GUI and a user-friendly touch panel, you can simultaneously control up to 256 indoor units, and the system can be linked to the building management system. Indoor unit tubing Deluxe Central Controller And especially, with an intuitively designed GUI and a user-friendly touch panel, you can simultaneously control up to 256 indoor units, and the system can be linked to the building management system. - Indoor unit max TFT LCD (800*600) - Touch screen panel - Available Ethernet protocol - Time schedule function - Error display and lock function - Length max 1km CNU IP I-Gateway 14 MPS(Multi Power System) Variable Multi

16 4. Features Long and High Elevation Piping(100k Btu/h models shown) It's an MPS Variable multi system with simple connecting refrigerant pipe, which is composed of one outdoor unit and some indoor units in series, so it saves energy greatly and makes the installation easy. ( Refer to "Part 5 Installation" for other models) Direct Piping [Outdoor Unit] Installation of the outdoor unit in an upper position A [Indoor Unit] B 30m Piping length : 50m( A ), 50m( B ) Total system piping length : 100m(50+50) [Indoor Unit] Installation of the outdoor unit in a lower position B [Outdoor Unit] 30m A 2004 Product Data 15

17 4. Features Distributor Piping [Outdoor Unit] Installation of the outdoor unit in an upper position A BD Unit L 1 [Indoor Unit] L 2 B L 3 BD Unit L 4 30m L 5 L 6 Total main piping length : 30m( A ), 30m( B ) Total branch piping length : 30m(L 1 +L 2 + L 3 ), 30m(L 4 +L 5 + L 6 ) Each branch piping length : 15m(L 1,L 2,L 3,L 4,L 5,L 6 ) Total system piping length : 60m(30+30), 60m(30+30) [Indoor Unit] BD Unit Installation of the outdoor unit in a lower position [Outdoor Unit] BD Unit 30m 16 MPS(Multi Power System) Variable Multi

18 4. Features 4.2 BD Unit Branch Distributor Unit - For Distributor piping - Unit for Variable Refrigerant Volume System PMBD5420L(For 2 indoor units) PMBD5430L(For 3 indoor units) PMBD5440L(For 4 indoor units) Compact Size Various models Quiet Operation (reduced refrigerant running noise of indoor unit) Flare Connection - No Brazing No need of drainage Installation Pattern Installation Pattern Ceiling-suspended type Wall-mounted type Screws(M5) (locally procude) Connection of Piping(Flare Work) - No Brazing & Easy Installation While connecting indoor units, make sure to connect refrigerant pipes and connection wires to the appropriate connection ports maked with matching alphabets. (A, B, C, D) NOTICE : Be sure to mark all the local refrigerant piping(liquid pipes, gas pipes, etc.) for each indoor unit designating clearly which room it belongs in.(a, B, C, D) Indoor unit tubing Flare nut Pipes Open-end wrench (fixed) Flare nut A B C D Wrench Indoor unit tubing Connection pipe E F G H [PMBD5440L] 2004 Product Data 17

19 4. Features 4.3 Indoor Unit Wall Mounted Type Innovative Quiet Operation CHAOS Swing JET Cool Healthy Dehumidification Triple Deodorizing Filter Nano Plasma Air Purifying System Auto Restart Wireless Remote Control Innovative Quiet Operation To provide a comfortable, pleasant and well balanced environment, LG air conditioners utilize a streamlined air fan and a unique design which create smooth air flow from the air conditioner so that it operates under the lowest noise level. The cross flow fan, stabilizer, and rear guide which are the causes of noise, have been redesigned by hydraulic engineering. The number of revolutions have been decreased or increased while the amount of friction has been decreased providing the most quiet air conditioners in the world. CHAOS Swing The most pleasant air flow for the human body can be found within nature. Countless data and verification resulted in the application of the new CHAOS theory to LG Air conditioners. Wind-up effect is controlled by vane angle and speed to evenly distribute nature-like air throughout the room. This function analyzes the characteristic of air flow distribution and creates the pleasant feeling of natural wind. Up Speed :Slow Down Speed :Fast Angle of vane movement JET Cool Jet Cooling function is for quick cooling. In this mode, strong and cool air is blown at high speeds for 30 minutes until the room temperature reaches to 18 C. Normal Jet Cool 3.8 M 5.8 M 18 MPS(Multi Power System) Variable Multi

20 4. Features Healthy Dehumidification The hot and humid air has a tendency to rise by convection. Healthy Dehumidification optimizes this algorithm to keep an optimum humidity without feeling cold in indoor place. Triple Deodorizing Filter - Triple Deodorizing Filter is adopted for absorbing VOC Ingredient, Structural material ingredient, Common Odor - Deodorizing efficiency : 10% up compared to normal Deodorization Filter Composition of Triple Deodorizing Filter Nasty smell Deodorizing Formaldehyde Deodorizing V.O.C. Deodorizing Dust particles Pre-filter Ionizer Dust electrode discharge Dusts Collection Air Purifying System - It not only removes microscopic contaminants & dust, but it also removes house mites, pollen, and pet fur to help prevent allergic diseases like asthma.it provides odor free, dust free and allergy free air. Polluted Air Odour (ppm) KV discharge Generating plasma Normal Filter + + Purified fresh Air dusts aluminum coated Odor molecule electrode(-) (3.25KV discharge) Effect of carbon Nano Ball Deodorizing efficieny: 8~10times compared to conventional carbon filter Nano Filter (Min) What is Carbon Nano Ball? Nano(1/1 Bil) ball structure, (200~500nm) consisted of carbon, is adopted as deodorizing material at first in the world Product Data 19

21 4. Features Ceiling Cassette 4 way Compact Design and Easy Installation Low noise Hygienic and Easy-to-Clean Filter 2-Thermistor; Unit Body and Remote Control Jet Cool Plasma Air Purifying System High Head Drain Pump(700mm) High-Ceiling Corresponding Operation LCD Wired Remote Control Wireless Remote Control(Accessory:LCD/Button) Group Control Group Control 1) Operation Summary - Where several products are linked, one specific control device can control a specific number of products. 2) Specific Operation - Connecting line is linked to each of the indoor equipments for communication. A specific control device is connected to each of them and this control device can control the same function. - Group control function is enabled by cutting an optional jump wire in the wired remote control. At this time, the main system will not respond in order to prevent data collision. - While executing group control command, use the random data (0-3minutes) in the main body of indoor equipment for limiting starting current. - Control device can control up to 16 indoor equipments Remote Controller Low Noise The most advanced low-noise design. The adoption of turbo-fan and round type heat exchanger provides the quietest operation. Hygienic and Easy-to-Clean Filter Washable and anti bacteria filter is adopted. It is easy to open grille and replace clean filter. 20 MPS(Multi Power System) Variable Multi

22 4. Features Plasma Air Purifying System The PLASMA Air Purifying Function not only removes microscopic contaminants and dust, but also removes house mites, pollen, and pet fur helps to prevent allergic diseases like asthma. Dust particles Polluted Air Dust electrode discharge Ionizer Photo-Catalyst Coated Mesh +4.8KV discharge Purified fresh Air + Odour Odour molecule Generating plasma High Head Drain Pump(700mm) Built-in Drain Pump drains out water automatically. A standard drain-head height of up to 700 mm is possible, creating the ideal solution for perfect water drainage. Pipe fixture Maximum 700mm Slope 1/50~1/100 Flexible drain hose Drain Pump Hard Tube(ex.PVC) Drain Pan Ceiling Board High-Ceiling Corresponding Operation According to the height of the installation, it provides variability of indoor fan motor rpm. If the height of installation is low then you can adjust low rpm of indoor fan motor. On the other hand if the height of the installation is high you can adjust high rpm of indoor fan motor. Selection of speed can be done by slide switch at the back of the LCD wired remote Product Data 21

23 4. Features Ceiling Concealed Duct High Static Pressure Compact Design and Easy Installation (Phase Control Motor) 2-Thermistor Control; Unit Body & Remote Control LCD Wired Remote Control Wireless Remote Control(Accessory) Plasma Air Purifying Kit(Accessory) High Head Drain Pump(Accessory:700mm) Zone Control(Accessory) Electric Heater(Accessory) Ceiling Concealed Duct Low Static Pressure Compact and Light design and Easy Installation (Phase Control Motor) 2-Thermistor Control; Unit Body & Remote Control LCD Wired Remote Control Wireless Remote Control(Accessory) High Head Drain Pump(Accessory) Easy Installation Flexible Duct is easy to install, regardless of room size or heater position. Canvas Duct Indoor Unit Ceiling It can be installed even in a limited space and saves construction cost with slim thickness Intake Duct Discharge Flexible Duct Air Intake Port Innovative Design of Fan and Housing System Ceiling Board Inspection Port Ceiling Board Air Discharge Port Low Noise! Easy Serviceability! Plastic Fan and Housing Assembly - Designed for low noise - Designed to reduce weight - Designed for easy service This product guarantees lower sound level and gives lesser service expenses. 22 MPS(Multi Power System) Variable Multi

24 4. Features LG s High Technology provide Easy and Low cost Design of Duct work Generally, when External Static Pressure increases air volume decreases. But by controlling the phase of motor while installing the product E.S.P. is controlled from 8~10 mmaq linearly. E.S.P. control provides required constant air volume irrespective of ESP change. Desired ESP can also be set through LCD wired remote control. Setting of the desired ESP gives required combination of ESP and airflow. Plasma Air Purifying Kit (Accessory) The PLASMA Air Purifying Function not only removes microscopic contaminants and dust, but also removes house mites, pollen, and pet fur helps to prevent allergic diseases like asthma. High Head Drain Pump(Accessory:700mm) In some of the places natural drainage is not possible. For such places drain pump is very useful. It removes condensed water from the unit. Zone Control(Accessory) It controls the temperature of each zone. Opening or closing of the damper is controlled by sensing the temperature of each zone. In the cooling mode, if the temperature of a particular zone is lower than set temperature then the damper is closed. On the other hand if the temperature of a particular zone is higher than the set temperature, damper is opened to provide cooling to the zone and vice versa in the heating mode Product Data 23

25 5. Control System 5.1 Various central control Unit name Image Function Remarks Simple Central Control Basic Model No.: PQCSA101S0 Control & Monitoring of 16 Indoor Units. It is possible to use max. 128 indoor units by connecting 8 Simple Centrol Controller. PQCSA101S0 : 16 indoor units, Simple central control, IEEE 485 transmission Central control Deluxe Central Control Basic Model No.: PQCSW501A0 Control & Monitoring of 256 Indoor Units. Schedule funcion(option) PQCSW501A0 : Control / Monitoring PQCSW502A0 : Control / Monitoring / Schedule PC Central Control Software Basic Model No.: PQCSS501A0 Control & Monitoring of 256 Indoor Units. Schedule funcion(option) PQCSS501A0 : Control / Monitoring PQCSS502A0 : Control / Monitoring / Schedule Interface Device CNU 1) Basic Model No.: PQNFG00A0 Gate-Way for Deluxe/PC Centrol Controller It is possible to use max. 16 outdoor units. Gate-Way for Simple/Deluxe/PC Centrol Controller PI485 2) It is used 1 unit per I outdoor unit. Basic Model No.: PMNFP00A0 1) CNU: Central contral Network intertace unit. 2) PI485: Product Interface unit for IEEE 485 transmission. Note: All the central control devices listed above are optional accessory, so these should be purchased separately when needed. 24 MPS(Multi Power System) Variable Multi

26 5. Control System 5.2 Control device Unit name Simple Central Control Basic Model No. : PQCSA101S0 Interface Gateway PI485 1 Outdoor unit : 1 Gateway Functions Simple On/Off control for 16 indoor units Individual / simultaneous operation control Set lock for each indoor unit Group control Monitoring operating state Error display Deluxe Central Control Basic Model No. : PQCSW501A0 CNU PI485 Connection: Webpad CNU PI485(Outdoor) Central control and monitoring for 256 indoor units 8.0 TFT LCD Touch screen panel Individual room temperature setting Group control Set lock for each indoor unit Error display PC Central Control Software Basic Model No. : PQCSS501A0 CNU PI485 Connection: Webpad CNU PI485(Outdoor) Central control and monitoring for 256 indoor units Easy installation and operation using LAN cable and user friendly simple GUI Individual room temperature setting Group control Set lock for each indoor unit Error display Scheduling(option) Peak power control(option) 2004 Product Data 25

27 26 MPS(Multi Power System) Variable Multi

28 Part 2 Indoor Units 1. Wall Mounted Ceiling Cassette 4-way Ceiling Concealed Duct - High Static Pressure Ceiling Concealed Duct - Low Static Pressure Product Data 27

29 LMNC-LR, LT LMNH-LR, LT 1. Wall Mounted 1. List of Functions Specifications Dimensional Drawings Wiring Diagrams Piping Diagrams Air Velocity and Temperature Distribution Sound Levels Installation Accessories MPS(Multi Power System) Variable Multi

30 1. List of Functions Features Model LMNC-LR/ LT, LMNH-LR/LT Airflow Direction Control(Left & Right) Manual Airflow Direction Control(Up & Down) Automatic Airflow Outlet 1 Airflow Steps(Fan / Cool / Heat) 3/4/3 Auto Changeover(Operation) - Auto Cleaning - Auto Restart Operation O Central Control Accessory CHAOS Wind(Auto Wind) O Child Lock Function - Cooling & Heating Fan Operation - Deice Control O(Only Heat Pump) Deodorizing Filter O(Triple) Drain Pump - E.S.P Control - Forced Operation O Group Control - High Ceiling Operation - Hot Start Function O(Only Heat Pump) Jet Cool O Plasma Air Purifying Filter O(NANO) Plasma Heat Exchanger - Prefilter(Washable / Anti-fungus) O Self Diagnosis Function O Sleep Mode Operation O Soft Dry Operation O Soft Start Function - Test Function O Time Delay Safety Function O Timer(24 Hour, On/Off) O Timer(Weekly, On/Off) - Two Thermistor Control - Wired LCD Remote Control - Wireless LCD Remote Control O Zero Stanby Power - Zone Control - Notes : O : Basic Optional : Factory-Installed Accessory : Field-Installed - : Not available on this system 2004 Product Data 29

31 2. Specification Heat Pump Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) inch(mm) Net Weight kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) Stuffing Quantity Without S/Parts 20/40ft Wall Mounted LMNH126LRL0 LMNH186LTL0 LMNH246LTL0 3024(3515) 4536(5275) 5796(6740) 12,000 18,000 23, (3515) 4536(5275) 5796(6740) 12,000 18,000 23, (318) 13(459) 14(494) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~ IC-8420LG48A AMR-023E2 AMR-023E / / / 370 Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.43(87) 1/3.74(95) 1/3.74(95) 38 / 36 / / 38 / / 42 / 38 Thermistor Thermistor Thermistor 0.197(5.0) 0.276(7.0) 0.276(7.0) R,12C 2R,13C 2R,13C *11.2*6.1(900*285*156) 42.9*12.4*6.8(1090*314*172) 42.9*12.4*6.8(1090*314*172) 9(19.8) 12(26.5) 12(26.5) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7) 1/2 (12.7) 5/8(15.88) *9.2*14.6(976*233*372) 45.9*10.0*15.3 (1165*255*388) 45.9*10.0*15.3 (1165*255*388) 340/ / /540 Cooling Only Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) inch(mm) Net Weight kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) Stuffing Quantity Without S/Parts 20/40ft Wall Mounted LMNC126LRL0 LMNC186LTL0 LMNC246LTL0 3024(3515) 4536(5275) 5796(6740) 12,000 18,000 23, (318) 13(459) 14(494) 18~30 / - 18~30 / - 18~30 / IC-8420LG48A AMR-023E2 AMR-023E / / / 370 Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.43(87) 1/3.74(95) 1/3.74(95) 38 / 36 / / 38 / / 42 / 38 Thermistor Thermistor Thermistor 0.197(5.0) 0.276(7.0) 0.276(7.0) R,12C 2R,13C 2R,13C *11.2*6.1(900*285*156) 42.9*12.4*6.8(1090*314*172) 42.9*12.4*6.8(1090*314*172) 9(19.8) 12(26.5) 12(26.5) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7) 1/2 (12.7) 5/8(15.88) *9.2*14.6(976*233*372) 45.9*10.0*15.3 (1165*255*388) 45.9*10.0*15.3 (1165*255*388) 340/ / /540 Notes:- 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. Heating: - Indoor Temperature 20 C(68 F) DB / 15 C(59 F) WB - Outdoor Temperature 7 C(44.6 F) DB / 6 C(42.8 F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. : See the page "Combination Table" Conversion Formula kcal/h = kw x 860 Btu/h = kw x 3412 cfm = m 3 /min x MPS(Multi Power System) Variable Multi

32 3. Dimensional Drawings LMNC-LR/LT, LMNH-LR/LT H More than 5cm More than 5cm W D More than 2.3m More than 5cm Installation plate Note: 1. Pipe Specification(mm) Model Liquid Gas 12k/18k Ø 6.35 Ø k Ø 6.35 Ø C D Installation plate B CHASSIS (Grade) SR(12k) A 0 Distance(mm) B C D 40 Ø70mm A Ø70mm ST(18/24k) Left rear piping Right rear piping (unit : mm) Model LMNC126LRL0 LMNH126LRL0 LMNC186LTL0 LMNH186LTL0 LMNC246LTL0 LMNH246LTL0 W H D Product Data 31

33 4. Wiring Diagrams CN-MOTOR AC PCB ASM DC PCB ASM CN-TH1 CN-TH2 THERMISTOR(OUT-PIPE) THERMISTOR(IN-PIPE) THERMISTOR(ROOM) ZNR CN-U/D FUSE 250V 2A CN-POWER 3854A20135W CONNECTOR NUMBER CN-POWER CN-MOTOR CN-ACDC CN-DISP CN-UD CN-LR CN-TH1 CN-TH2 LOCATION AC POWER SUPPLY AC FAN MOTOR OUTPUT AC/DC CONNECTION DISPLAY STEP MOTOR STEP MOTOR ROOM/PIPE SENSOR DISCHARGE PIPE SENSOR 32 MPS(Multi Power System) Variable Multi

34 5. Piping Diagrams Heat Exchanger :Cooling :Heating C.F.F lndoor unit : Thermistor Refrigerant pipe connection port diameter [unit:mm(inch)] Model LMNC126LRL0 LMNH126LRL0 LMNC186LTL0 LMNH186LTL0 LMNC246LTL0 LMNH246LTL0 Gas Ø12.7(1/2) Ø15.88(5/8) Liquid Ø6.35(1/4) 2004 Product Data 33

35 6. Air Velocity and Temperature Distributions(Reference Data) 12k Btu/h Model Cooling Heating Air velocity [m/s] 2.7m Air velocity [m/s] 2.7m 2m 2m m 1.0 1m 5m 4m 3m 2m 0.5 1m 0m 0m 5m 4m 3m 2m 1m 0m 0m Temperature [ßC] 2.7m Temperature [ßC] 2.7m 18 2m m 20 1m m 5m 4m 3m 24 2m 22 1m 0m 0m 5m 4m 3m 2m 1m 0m 0m 18k Btu/h Model Cooling Heating Air velocity [m/s] 2.7m Air velocity [m/s] 2.7m 2m 2m 8m 7m 6m 5m 4m 0.5 3m 1.0 2m 1.5 1m 2.5 1m 0m 0m 8m 7m 6m 0.5 5m 4m 3m 1.0 2m m 1m 0m 0m Temperature [ßC] 2.7m Temperature [ßC] 2.7m 18 2m 33 2m 8m 7m 6m 5m m 3m 2m 1m 20 1m 0m 0m 8m 7m 6m 21 5m 4m 3m 24 2m 27 1m 30 1m 0m 0m 34 MPS(Multi Power System) Variable Multi

36 7. Sound Levels Overall 1m 0.8m Microphone Notes: - Sound measured at 1m away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20µPa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(ks conditions). Model LMNC126LRL0 LMNH126LRL0 LMNC186LTL0 LMNH186LTL0 LMNC246LTL0 LMNH246LTL0 Sound Levels(dBA) H M L Sound Pressure Level LMNC126LRL0 LMNH126LRL0 LMNC186LTL0 LMNH186LTL0 LMNC246LTL0 LMNH246LTL Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 NC NC-25 NC NC-25 NC-20 NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) 2004 Product Data 35

37 8. Installation Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Installation Parts Provided 1. Type "A" screw 2. Installation Plate 3. Type "B" screw 4. Holder Remote Control Cooling & Heating Model has included Drain Elbow. Required Parts Installation plate Four type "A" screws Connecting cable Required Tools Level gauge Screw driver Electric drill Hole core drill(ø70mm) Pipes: Gas side...ø12.7, Ø15.88mm Liquid side...ø6.35 mm Insulation materials Additional drain pipe (Inner Diameter...20mm) Flaring tool set Specified torque wrenches 1.8kg.m, 4.2kg.m, 5.5kg.m, 6.6kg.m (different depending on model No.) Spanner...Half union A glass of water Screw driver Two type "B" screws Owner's manual Thermometer Holder Remote Control 36 MPS(Multi Power System) Variable Multi

38 8. Installation 8.1 Selection of the best location There should not be any heat source or steam near the unit. There should not be any obstacles to prevent the air circulation. There should be easy provision of condensate drain. Taking into account the noise prevention criteria, spot the installation location. Do not install the unit near the door way. Keep proper distance, of the unit, from ceiling fence, floor, walls & other obstacles as shown in figure. The mounting wall should be strong and solid enough to protect it from the vibration. 1) Mount the installation plate on the wall with four Type "A" screws. (If mounting the unit on the concrete wall, consider using anchor bolts.) Always mount the Installation plate horizontally by aligning the marking-off line by means of the thread and a level. Right More than 5 cm Front Rear right Higher than eye-level Down right Lower than 2.3m More than 5 cm Left Rear left More than 5 cm Installation Plate Type "A" screw marking-off line Thread Weight The lower left and the right side of Installation Plate C D Installation plate B CHASSIS (Grade) SR(12k) A 0 Distance(mm) B C D 40 Ø70mm A Ø70mm ST(18/24k) Left rear piping Right rear piping 2004 Product Data 37

39 8. Installation 8.2 Connection of pipings Preparing the indoor unit's piping and drain hose for installation through the wall. Remove the plastic tubing retainer(see illustration below) and pull the tubing and drain hose away from chassis. Replace the plastic tubing holder in the original position. 3. Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Loop To remove the holder, press the bottom of chassis near the holder upward and pull the tab out of its hole. For left rear piping Tubing holder CAUTION When install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable. 2 Pull 1 Press 1. Route the indoor tubing and the drain hose in the direction of rear left. Connecting cable Drain hose Gas side piping Liquid side piping NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended. 4. Indoor unit installation Hook the indoor unit onto the upper portion of the installation plate.(engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right. Connecting cable Drain hose Drain hose 2. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole. Do not connect the cable to the indoor unit. Make a small loop with the cable for easy connection later. Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). 5. Connecting the pipings to the indoor unit and drain hose to drain pipe. Align the center of the pipings and sufficiently tighten the flare nut by hand. Indoor unit tubing Flare nut Pipings 38 MPS(Multi Power System) Variable Multi

40 8. Installation Tighten the flare nut with a wrench. Torque wrench Indoor unit tubing Spanner (fixed) Flare nut Connection pipe Wrap the area which accommodates the rear piping housing section with vinyl tape. Connection pipe Vinyl tape (wide) Connecting cable Indoor unit pipe Wrap with vinyl tape Pipe Vinyl tape(narrow) When extending the drain hose at the indoor unit, install the drain pipe. Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section. Wrap with vinyl tape Pipe Drain pipe Drain hose Vinyl tape(wide) Indoor unit drain hose Vinyl tape(narrow) Adhesive 6. Wrap the insulation material around the connecting portion. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap. 1. Route the indoor tubing and the drain hose to the required piping hole position. Plastic bands Insulation material 2. Insert the piping, drain hose and the connecting cable into the piping hole. Connecting cable Drain pipe 2004 Product Data 39

41 8. Installation 3. Insert the connecting cable into the indoor unit. Don't connect the cable to the indoor unit. Make a small loop with the cable for easy connection later. 4. Tape the drain hose and the connecting cable. Connecting cable GAS Ø12.7[5.5kg.m] Ø15.88[6.6kg.m] Pipe Size[Torque] LIQUID Ø6.35[1.8kg.m] Ø9.52[4.2kg.m] When extending the drain hose at the indoor unit, install the drain pipe. Drain hose 5. Indoor unit installation Hang the indoor unit from the hooks at the top of the installation plate. Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall. Indoor unit Spacer Indoor unit drain hose Vinyl tape(narrow) Adhesive 7. Wrap the insulation material around the connecting portion. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap. Plastic bands Insulation material Installation plate 8cm 6. Connecting the pipings to the indoor unit and the drain hose to drain pipe. Align the center of the pipings and sufficiently tighten the flare nut by hand. Wrap the area which accommodates the rear piping housing section with vinyl tape. Connection pipe Vinyl tape (wide) Indoor unit piping Wrap with vinyl tape Indoor unit tubing Flare nut Pipings Tighten the flare nut with a wrench. Connecting cable Pipe Vinyl tape (narrow) Spanner (fixed) Torque wrench Indoor unit tubing Flare nut Connection pipe 40 MPS(Multi Power System) Variable Multi

42 8. Installation Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. 10. Indoor unit installation Remove the spacer. Ensure that the hooks are properly seated on the installation plate by moving it left and right. Drain hose Pipe Vinyl tape (narrow) Connecting cable Wrap with vinyl tape(wide) Drain hose 8. Adjust the pipings and the drain hose across the back of the chassis. Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). Piping for passage through piping hole 9. Set the pipings and the drain hose to the back of the chassis with the tubing holder. Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis. Tubing holder 1 Hook 2 Push 2004 Product Data 41

43 8. Installation 8.3 Checking the drainage 1. To remove the front panel from the indoor unit, remove the front panel from the indoor unit cabinet. Set the air direction louvers up-and-down to the position(horizontally) by hand. Remove the securing screws that retain the front panel. Pull the lower left and right sides of the grille toward you and lift it off. (2.1/7, 2.6/9, 3.5/12 kw/btu models: 2EA, 3.5/18 kw/btu models: 3EA) 2. To check the drainage. Pour a glass of water on the evaporator. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. Pull the right and the left side. Screw 8.4 Connecting the cable 1) Connect the wires to the terminals on the control board individually according to the outdoor unit connection. Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively. Connecting cable 42 MPS(Multi Power System) Variable Multi

44 8. Installation Terminal Block in Indoor 1(L) 2(N) 3 4 Connected to Outdoor Unit(or BD Unit) 2) Attach the Grille onto the cabinet. Grasp lower the left and right side of the Grille and engage four tabs on the top inside edge of the chassis. Press the Grille toward the chassis until it will be back into place. CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3) Specification of power source. 4) Confirm that electrical capacity is sufficient. 5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6) Confirm that the cable thickness is as specified in the power source specification. (Particularly note the relation between cable length and thickness.) 7) In a wet or moist area, always install an earth leakage circuit breaker. 8) The following would be caused by voltage drop. Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload. 9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors Product Data 43

45 9. Accessories Standard Accessories Name Installation panel Insulating tape Clamp Securing screws Insulation for fitting Quantity 1 set 1 EA 4 EA 2 EA 1 set Shape for gas pipe M4 x 12L for liquid pipe Name (Other) Quantity Owner's manual Installation manual Shape 44 MPS(Multi Power System) Variable Multi

46 LMNC-TE, TF, TD LMNH-TE, TF, TD 2. Ceiling Cassette 4-way 1. List of Functions Specifications Dimensional Drawings Wiring Diagrams Piping Diagrams Air Velocity and Temperature Distribution Sound Levels Installation Accessories Product Data 45

47 1. List of Functions Features Model LMNC-TE/TF/TD, LMNH-TE/TF/ TD Airflow Direction Control(Left & Right) Manual Airflow Direction Control(Up & Down) Automatic Airflow Outlet 4 Airflow Steps(Fan / Cool / Heat) 3/4/3 Auto Changeover(Operation) - Auto Cleaning - Auto Restart Operation O Central Control Accessory CHAOS Wind(Auto Wind) - Child Lock Function O Cooling & Heating Fan Operation O Deice Control O(Only Heat Pump) Deodorizing Filter O Drain Pump O E.S.P Control - Forced Operation O Group Control O High Ceiling Operation O Hot Start Function O(Only Heat Pump) Jet Cool O Plasma Air Purifying Filter O Plasma Heat Exchanger - Prefilter(Washable / Anti-fungus) O Self Diagnosis Function O Sleep Mode Operation - Soft Dry Operation O Soft Start Function - Test Function O Time Delay Safety Function O Timer(24 Hour, On/Off) O Timer(Weekly, On/Off) O Two Thermistor Control O Wired LCD Remote Control O Wireless LCD Remote Control Accessory Zero Stanby Power - Zone Control - Notes : O : Basic Optional : Factory-Installed Accessory : Field-Installed - : Not available on this system 46 MPS(Multi Power System) Variable Multi

48 2. Specification Heat Pump Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Decorative panel inch(mm) Net Weight Body kg(lbs) Panel kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (OD Ø) mm Packing Dimension Body inch(mm) (W*H*D) Panel inch(mm) Stuffing Quantity With(without) S/Parts 20/40ft Ceilling Cassette - 4way LMNH126TEC0 LMNH186TEC0 LMNH246TFC0 3024(3515) 4536(5275) 6048(7033) (3515) 4536(5275) 6048(7033) /8/7(336/283/247) 13/12/11(459/424/388) 15/14/13(530/494/459) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~ IC-9630LGAE IC-9630LGAC OBM / /440 4/450 Turbo Fan Turbo Fan Turbo Fan 1/13.0(330) 1/13.0(330) 1/15.0(382) 38/35/32 41/39/37 43/41/39 Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) R11C 2R11C 2R12C *10.5*22.4 (570*269*570) 22.4*10.5*22.4 (570*269*570) 29.3*11.5*29.4 (744*292*744) 26.4*1.2*26.4 (670*30*670) 26.4*1.2 *26.4(670*30*670) 33.5*1.2 *33.5(850*30*850) 19(41.9) 19(41.9) 24(52.9) 3(6.6) 3(6.6) 3(6.6) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7) 1/2 (12.7) 5/8 (15.88) 1.26(32) 1.26(32) 1.26(32) 25.2*13.0*25.2(640*330*640) 25.2*13.0*25.2(640*330*640) 32.6*14.4*32.6(828*365*828) 29.5*3.1*29.5(750*80*750) 29.5*3.1*29.5(750*80*750) 36.8*3.5*36.8(935*90*935) 189/ /378 84/168 Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Decorative panel inch(mm) Net Weight Body kg(lbs) Panel kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (OD Ø) mm Packing Dimension Body inch(mm) (W*H*D) Panel inch(mm) Stuffing Quantity With(without) S/Parts 20/40ft Notes:- 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. Heating: - Indoor Temperature 20 C(68 F) DB / 15 C(59 F) WB - Outdoor Temperature 7 C(44.6 F) DB / 6 C(42.8 F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. Ceilling Cassette - 4way LMNH306TFC0 LMNH366TDC0 LMNH486TDC0 7055(8204) 9072(10549) 12095(14065) (8204) 9072(10549) 12095(14065) /17/15(671/600/530) 25/23/21(883/812/742) 33/30/27(1164/1059/953) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~ IC-1630LGPJ IC-1630LGPJ IC-1630LGPH /450 4/450 6/450 Turbo Fan Turbo Fan Turbo Fan 1/18.1(460) 1/18.1(460) 1/18.1(460) 40/38/36 40/38/36 43/41/39 Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) R12C 2R12C 2R12C *11.5*29.4 (744*292*744) 33.1*11.3*33.1 (840*288*840) 33.1*11.3*33.1 (840*288*840) 33.5*1.2 *33.5(850*30*850) 37.4*1.2 *37.4(950*30*950) 37.4*1.2 *37.4(950*30*950) 33(72.7) 33(72.7) 33(72.7) 5(11) 5(11) 5(11) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 3/4 (19.05) 1.26(32) 1.26(32) 1.26(32) 32.6*14.4*32.6(828*365*828) 36.4*13.8*36.4(925*350*925) 36.4*13.8*36.4(925*350*925) 36.8*3.5*36.8(935*90*935) 40.6*3.5*40.6(1,030*90*1,030) 40.6*3.5*40.6(1,030*90*1,030) 84/168 71/144 71/ Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. : See the page "Combination Table" 2004 Product Data 47

49 2. Specification Cooling Only Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Decorative panel inch(mm) Net Weight Body kg(lbs) Panel kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (OD Ø) mm Packing Dimension Body inch(mm) (W*H*D) Panel inch(mm) Stuffing Quantity With(without) S/Parts 20/40ft Ceilling Cassette - 4way LMNC126TEC0 LMNC186TEC0 LMNC246TFC0 3024(3515) 4536(5275) 6048(7033) /8/7(336/283/247) 13/12/11(459/424/388) 15/14/13(530/494/459) 18~30 / - 18~30 / - 18~30 / IC-9630LGAE IC-9630LGAC OBM / /440 4/450 Turbo Fan Turbo Fan Turbo Fan 1/13.0(330) 1/13.0(330) 1/15.0(382) 38/35/32 41/39/37 43/41/39 Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) R11C 2R11C 2R12C *10.5*22.4 (570*269*570) 22.4*10.5*22.4 (570*269*570) 29.3*11.5*29.4 (744*292*744) 26.4*1.2*26.4 (670*30*670) 26.4*1.2 *26.4(670*30*670) 33.5*1.2 *33.5(850*30*850) 19(41.9) 19(41.9) 24(52.9) 3(6.6) 3(6.6) 3(6.6) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7) 1/2 (12.7) 5/8 (15.88) 1.26(32) 1.26(32) 1.26(32) 25.2*13.0*25.2(640*330*640) 25.2*13.0*25.2(640*330*640) 32.6*14.4*32.6(828*365*828) 29.5*3.1*29.5(750*80*750) 29.5*3.1*29.5(750*80*750) 36.8*3.5*36.8(935*90*935) 189/ /378 84/168 Indoor Unit Type Ceilling Cassette - 4way Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Decorative panel inch(mm) Net Weight Body kg(lbs) Panel kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (OD Ø) mm Packing Dimension Body inch(mm) (W*H*D) Panel inch(mm) Stuffing Quantity With(without) S/Parts 20/40ft Notes:- 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. : See the page "Combination Table" LMNC306TFC0 LMNC366TDC0 LMNC486TDC0 7055(8204) 9072(10549) 12095(14065) /17/15(671/600/530) 25/23/21(883/812/742) 33/30/27(1164/1059/953) 18~30 / - 18~30 / - 18~30 / IC-1630LGPJ IC-1630LGPJ IC-1630LGPH /450 4/450 6/450 Turbo Fan Turbo Fan Turbo Fan 1/18.1(460) 1/18.1(460) 1/18.1(460) 40/38/36 40/38/36 43/41/39 Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) R12C 2R12C 2R12C *11.5*29.4 (744*292*744) 33.1*11.3*33.1 (840*288*840) 33.1*11.3*33.1 (840*288*840) 33.5*1.2 *33.5(850*30*850) 37.4*1.2 *37.4(950*30*950) 37.4*1.2 *37.4(950*30*950) 33(72.7) 33(72.7) 33(72.7) 5(11) 5(11) 5(11) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 3/4 (19.05) 1.26(32) 1.26(32) 1.26(32) 32.6*14.4*32.6(828*365*828) 36.4*13.8*36.4 (925*350*925) 36.4*13.8*36.4 (925*350*925) 36.8*3.5*36.8(935*90*935) 40.6*3.5*40.6(1,030*90*1,030) 40.6*3.5*40.6(1,030*90*1,030) 84/168 71/144 71/ MPS(Multi Power System) Variable Multi

50 3. Dimensional Drawings LMNC-TE, LMNH-TE 600 (Ceiling opening) (Hanging bolt) Unit size 570 Unit size 450 (Hanging bolt) (Ceiling opening) Unit:mm (unit : mm) Number Name Descripition 1 Liquid pipe connection ø6.35 flare 2 Gas pipe connection ø12.7 flare 3 Drain pipe connection 4 Power supply connection 5 Air discharge grill 6 Air suction grill 2004 Product Data 49

51 3. Dimensional Drawings LMNC-TF, LMNH-TF 790 (Ceiling opening) (Hanging bolt) Unit size 744 Unit size 658 (Hanging bolt) (Ceiling opening) 66 Unit:mm (unit : mm) Number Name Descripition 1 Liquid pipe connection ø6.35 flare 2 Gas pipe connection ø15.88 flare 3 Drain pipe connection 4 Power supply connection 5 Air discharge grill 6 Air suction grill 50 MPS(Multi Power System) Variable Multi

52 3. Dimensional Drawings LMNC-TD, LMNH-TD 875 (Ceiling opening) (Hanging bolt) Unit size 840 Unit size (Hanging bolt) (Ceiling opening) Unit:mm (unit : mm) Number Name Descripition 1 Liquid pipe connection 36k: Ø6.35flare, 48k: Ø9.52flare 2 Gas pipe connection 36k: Ø15.88flare, 48k: Ø19.05flare 3 Drain pipe connection 4 Power supply connection 5 Air discharge grill 6 Air suction grill 2004 Product Data 51

53 4. Wiring Diagrams WIRING DIAGRAM OUT-PIPE THERMISTOR ROOM THERMISTOR IN-PIPE THERMISTOR DOOR S/W HVB A/CL UNIT STEP MOTOR STEP MOTOR STEP MOTOR STEP MOTOR CENTRAL CONTROL TELE CONTROL GRILL CONTROL CN-PIPE2 CN-REMO REMOTE CONTROL CN-ROOM CN-PTC PTC HEATER CN-PIPE1 CN-HVB CN-FLOATCN-DISP FLOAT S/W DISPLAY PCB ASSY CN- MOTOR CAPACITOR CN-UD1 CN-UD2 CN-LR1 CN-LR2 INDOOR MOTOR DRAIN PUMP CN- DPUMP VENTIL UNIT GN/YL FUSE CN- VENTIL 2(N) 3 1(L) OPTION RD GN/YL BL BR TO OUTDOOR UNIT 3854A20419C CONNECTOR NUMBER CN-POWER CN-MOTOR CN-D/PUMP CN-DISP CN-FLOAT CN-PTC CN-REMO CN-GRILL CN-CC CN-PIPE2 CN-ROOM CN-PIPE1 CN-HVB CN-UD1 CN-UD2 CN-LR1 CN-LR2 LOCATION AC POWER SUPPLY BLDC FAN MOTOR OUTPUT DRAIN PUMP OUTPUT DISPLAY FLOAT SWITCH INPUT PTC HEATER INUT REMOTE CONTROL GRILL CONTROL CENTRAL CONTROL DISCHARGE PIPE SENSOR ROOM SENSOR PIPE SENSOR AIR CLEANER STEP MOTOR STEP MOTOR STEP MOTOR STEP MOTOR 52 MPS(Multi Power System) Variable Multi

54 5. Piping Diagrams Heat Exchanger :Cooling :Heating Turbo Fan lndoor unit : Thermistor Refrigerant pipe connection port diameter [unit: mm(inch)] Model Gas Liquid LMNC126TEC0 LMNH126TEC0 LMNC186TEC0 12.7(1/2) LMNH186TEC0 LMNC246TFC0 LMNH246TFC0 6.35(1/4) LMNC306TFC0 LMNH306TFC (5/8) LMNC366TDC0 LMNH366TDC0 LMNC486TDC0 LMNH486TDC (3/4) 9.52(3/8) 2004 Product Data 53

55 6. Air Velocity and Temperature Distributions(Reference Data) 18k Btu/h Model Cooling Discharge angle:45 Heating Discharge angle:50 Air velocity [m/s] Air velocity [m/s] m 2m m 2m m m 4m 3m 2m 1m 0m 1m 2m 3m 0m 4m 4m 3m 2m 1m 0m 1m 2m 3m 0m 4m Temperature [ C] Temperature [ C] 4m 3m 2m 1m m 1m 2m 3m 2.7m 2m 1m 0m 4m 4m 3m 2m 1m m 1m 2m 3m 2.7m 2m 1m 0m 4m 36k Btu/h Model Air velocity [m/s] 2.7m Air velocity [m/s] 2.7m 4m 3m 2m m 0m 1m 2m 3m 2m 1m 0m 4m 4m 3m 2m 1m m 1m 2m 3m 2m 1m 0m 4m Temperature [ C] m 2m Temperature [ C] m 2m 4m m 2m 1m 0m 1m 2m 3m 1m 0m 4m 4m 3m m 1m 0m 1m 2m 3m 1m 0m 4m 54 MPS(Multi Power System) Variable Multi

56 7. Sound Levels Overall 1.5m Ceiling Notes: - Sound measured at 1.5m below the center of the unit. - Data is valid at free field condition - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20µPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(ks conditions) Model Sound Levels(dBA) H M L Model Sound Levels(dBA) H M L LMNC/H126TEC LMNC/H306TFC LMNC/H186TEC0 LMNC/H246TFC LMNC/H366TDC0 LMNC/H486TDC Sound Pressure Level LMNC/H126TEC0 LMNC/H186TEC0 LMNC/H246TFC Sound Pressure Level (db re 20uPa) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20uPa) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20uPa) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC NC NC-25 NC-20 NC-20 NC-20 NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) LMNC/H306TFC0 LMNC/H366TDC0 LMNC/H486TDC Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 NC NC-25 NC NC-25 NC-20 NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) 2004 Product Data 55

57 8. Installation Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Anti-bacteria filter Air Outlet Air Intake Required Parts Connecting cable Pipes: Gas side Liquid side Hanging Bolt (W 3/8 or M10 length 650mm) Insulated drain hose Additional Drain hose (Outer Diameter...32mm) Required Tools Level Screw driver Electric drill Hole core drill (ø70mm) Flaring Tools set Torque Wrenches Hexagonal Wrench (4mm, 5mm) Gas-leak detector Owner s Manual Thermometer 8.1 Selection of the best location There should not be any heat source or steam near the unit. There should not be any obstacles to the air circulation. There should be provision of easy condensate drain. Taking into accounting the noise prevention criteria, spot the installation location. Do not install the unit near the door way. Keep proper distances, of the unit, from ceiling, fence, floor, walls and other obstacles as shown in figure. The indoor unit must have the maintenance space. Ceiling Ceiling Board 50 or more 100 or more Above or less Floor 30 or more Ceiling Board 50 or more Unit:cm 30 or less 56 MPS(Multi Power System) Variable Multi

58 8. Installation 8.2 Ceiling opening dimensions and hanging bolt location The dimensions of the paper pattern for installation are the same as those of the ceiling opening dimensions. Ceiling Level gauge Ceiling board TE Model TF Model TD Model (Ceiling opening) 521(Hanging bolt) (Ceiling opening) 572(Hanging bolt) (Ceiling opening) 785(Hanging bolt) Unit size 570 Unit size 672 (Hanging bolt) (Ceiling opening) 744 Unit size 744 Unit size (Hanging bolt) (Ceiling opening) 840 Unit size 840 Unit size (Hanging bolt) (Ceiling opening) 75 Unit:mm Unit:mm Unit:mm CAUTION This air-conditioner uses a drain pump. Install the unit horizontally using a level gauge. During the installation, care should be taken not to damage electric wires. Select and mark the position for fixing bolts and piping hole. Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. Drill the hole for anchor bolt on the wall. NOTE: Avoid the following installation location. 1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions; Make sure that ventilation fan is enough to cover all noxious gases from this place. Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam. Air conditioner Take enough distance Cooking table Use the ventilation fan for smoke-collecting hood with sufficient capacity. 2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. 3. Avoid places where inflammable gas is generated. 4. Avoid place where noxious gas is generated. 5. Avoid places near high frequency generators Product Data 57

59 8. Installation Ceiling Hanging bolt (W3/8 or M10) Nut (W3/8 or M10) Spring washer (M10) Keep the length of the bolt from the bracket to 40mm Flat washer for M10 (accessory) Ceiling board Air Conditioner body 150mm Ceiling board Flat washer for M10 (accessory) Nut (W3/8 or M10) Paper pattern for installation Adjust the same height Set screw of paper pattern (4 pieces) Open the ceiling board along the outer edge of the paper pattern. The following parts are local purchasing. Hanging Bolt - W 3/8 or M10 Nut - W 3/8 or M10 Spring Washer - M10 Plate Washer - M10 CAUTION Tighten the nut and bolt to prevent unit from falling off. 8.3 Wiring Connection Open the control box cover and connect the remote control cord and Indoor power wires. Indoor power cord Remote controller cord Control box cover Control box cover fitting screw(2 units) [Air inlet side view] Terminal Block in Indoor 1(L) 2(N) 3 4 Connected to Outdoor Unit(or BD Unit) WARNING Make sure that the screws of the terminal are free from looseness. 58 MPS(Multi Power System) Variable Multi

60 8. Installation 8.4 Installation of Decoration Panel The decoration panel has its installation direction. Before installing the decoration panel, always remove the paper template. 1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by amount 10mm in length.) The fixing screws (hexagon M5 screw) are included the indoor unit box. 2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.) 3. Hook the decoration panel key hole ( ) on the screws fixed in step above, and slide the panel so that the screws reach the key hole edge. 4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws) 5. Connect the louver motor connector and display connector. 6. After tightening these screws, install the air inlet grille (including the air filter). Air conditioner unit Piping side Decoration panel fixing screws (hexagon M5 screws) Temporally fitting at 2 places (Tightening about 10mm) Inlet Louver Grille motor Control box cover Decoration panel Key holes Display Lead wire for louver motor and display Decoration panel fixing screws (Hexagon M5 screw) Inlet Grille CAUTION Install certainly the decoration panel. Cool air leakage causes sweating. Water drops fall. Good example Air conditioner unit Bad example Air Air conditioner unit Cool air leakage (no good) Ceiling board Decoration panel Fit the insulator (this part) and be careful for cool air leakage Ceiling board Decoration panel 2004 Product Data 59

61 8. Installation 8.5 Indoor Unit Drain Piping Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow. During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit. The outside diameter of the drain connection on the indoor unit is 32mm. Piping material: Polyvinyl chloride pipe VP-25 and pipe fittings Be sure to install heat insulation on the drain piping. Heat insulation material: Polyethylene foam with thickness more than 8 mm. Drain test Pipe clamp Indoor unit Maintenance drain port Upward routing not allowed 1/50~1/100 MAX 700mm The air conditioner uses a drain pump to drain water. Use the following procedure to test the drain pump operation: Feed water Drain Pump Drain pan CAUTION Flexible drain hose (accessory) Main drain pipe Drain port Glue the joint Drain hose connection Use the clip (accessory) The supplied flexible drain hose should not be curved, neither screwed. The curved or screwed hose may cause a leakage of water. Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end. Feed water to the flexible drain hose and check the piping for leakage. Be sure to check the drain pump for normal operating and noise when electrical wiring is complete. When the test is complete, connect the flexible drain hose to the drain port on the indoor unit. Flexible drain hose 1/50~1/100 MAX 700mm CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guided by the circuit diagram pasted on the inside of control box cover. 2) Provide a circuit breaker switch between power source and the unit. 3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.) 4) Specification of power source 5) Confirm that electrical capacity is sufficient. 6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 7) Confirm that the cable thickness is as specified in the power sources specification. (Particularly note the relation between cable length and thickness.) 8) Never fail to equip a leakage breaker where it is wet or moist. 9) The following troubles would be caused by voltage drop-down. Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protection device. Proper starting power is not given to the compressor. 60 MPS(Multi Power System) Variable Multi

62 9. Accessories Standard Accessories Name Drain hose Clamp metal Washer for hanging backet Clamp Insulation for fitting (Other) Quantity 1 EA 1 EA 8 EA 8 EA 1 SET Shape for gas pipe Paper pattern for installation Owner's manual Installation manual for liquid pipe Optional Accessories(For Unit) No. Item Type Model No. Component Parts 1 Wireless remote control With air purifying function AHWRHD Wireless remote control : 1EA Holder : 1EA Battery : 2EA Screw : 2EA 2004 Product Data 61

63 LMNC-BH, BG, BE LMNH-BH, BG, BE 3. Ceiling Concealed Duct - High Static Pressure 1. List of Functions Specifications Dimensional Drawings Wiring Diagrams Piping Diagrams External Static Pressure & Air Flow E.S.P. Setting for Phase Control Motor Sound Levels Installation Accessories MPS(Multi Power System) Variable Multi

64 1. List of Functions Features Model LMNC-BH/BG LMNH-BH/BG Airflow Direction Control(Left & Right) - Airflow Direction Control(Up & Down) - Airflow Outlet 1 Airflow Steps(Fan / Cool / Heat) 3/3/3 Auto Changeover(Operation) - Auto Cleaning - Auto Restart Operation O Central Control Accessory CHAOS Wind(Auto Wind) - Child Lock Function O Cooling & Heating Fan Operation O Deice Control O(Only Heat Pump) Deodorizing Filter - Drain Pump Accessory E.S.P Control O Forced Operation O Group Control O High Ceiling Operation - Hot Start Function O(Only Heat Pump) Jet Cool - Plasma Air Purifying Filter Accessory Plasma Heat Exchanger - Prefilter(Washable / Anti-fungus) O Self Diagnosis Function O Sleep Mode Operation - Soft Dry Operation O Soft Start Function - Test Function O Time Delay Safety Function O Timer(24 Hour, On/Off) O Timer(Weekly, On/Off) O Two Thermistor Control O Wired LCD Remote Control O Wireless LCD Remote Control Accessory Zero Stanby Power - Zone Control Accessory LMNC-BE LMNH-BE /3/3 - - O Accessory - O O O(Only Heat Pump) - Accessory - O O - O(Only Heat Pump) - Accessory - O O - O - O O O O O O Accessory - Accessory Notes : O : Basic Optional : Factory-Installed Accessory : Field-Installed - : Not available on this system 2004 Product Data 63

65 2. Specification Heat Pump Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) External Static Pressure mmaq Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Net Weight kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) Stuffing Quantity With(Without) S/Parts 20/40ft Cooling Only Indoor Unit Type Ceilling Concealed Duct - High Static LMNH186BHA0 LMNH246BHA0 LMNH306BGA0 LMNH366BGA0 LMNH486BEA0 4536(5275) 6048(7034) 7560(8792) 9072(10551) 12096(14064) 18,000 24, (5275) 6048(7034) 7560(8792) 9072(10551) 12096(14064) 18,000 24, /14.5/13(583/512/459) 18/16.5/14(636/583/494) 26.5/23/20(936/812/706) 32/29/26.5(1130/1024/936) 40/36/30(1412/1270/1059) ~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~ IC-13450LG13C IC-13450LG13C IC-13450LG13E IC-13450LG13E AVA-A12EX /370 6/370 6/370 6/370 12/450 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan 2/6.97(177) 2/6.97(177) 2/6.97(177) 2/6.97(177) - 36 / 34 / 32 38/36/34 40/38/35 42/39/36 43/41/39 Thermistor Thermistor Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) 0.275(7) 0.275(7) R10C 3R10C 3R,12C 3R,12C 3R,14C *10.2*17.7(880*260*450) 34.6*10.2*17.7 (880*260*450) 46.4*11.7 *17.7 (1180*298*450) 46.4*11.7 *17.7(1180*298*450) 48.43*41.57*26.77(1230*370*680) 35(77.2) 35(77.2) 38(83.8) 38(83.8) 70(154.3) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8(9.52) 1/2 (12.7) 5/8(15.88) 5/8(15.88) 5/8(15.88) 3/4(19.05) *13.4*23.0 (1135*340*585) 44.7*13.4*23.0 (1135*340*585) 56.5*14.8*23.0(1435*375*585) 56.5*14.8*23.0 (1435*375*585) 58.3*18.1*31.9(1480*460*810) 120/ /252 95/191 95/191 50/110 Ceilling Concealed Duct - High Static Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) External Static Pressure mmaq Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Net Weight kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) Stuffing Quantity With(Without) S/Parts 20/40ft Notes:- 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. Heating: - Indoor Temperature 20 C(68 F) DB / 15 C(59 F) WB - Outdoor Temperature 7 C(44.6 F) DB / 6 C(42.8 F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. : See the page "Combination Table" 64 MPS(Multi Power System) Variable Multi LMNC186BHA0 LMNC246BHA0 LMNC306BGA0 LMNC366BGA0 LMNC486BEA0 4536(5275) 6048(7034) 7560(8792) 9072(10551) 12096(14064) 18,000 24, /14.5/13(583/512/459) 18/16.5/14(636/583/494) 26.5/23/20(936/812/706) 32/29/26.5(1130/1024/936) 40/36/30(1412/1270/1059) ~30 / - 18~30 / - 18~30 / - 18~30 / - 18~30 / IC-13450LG13C IC-13450LG13C IC-13450LG13E IC-13450LG13E AVA-A12EX /370 6/370 6/370 6/370 12/450 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan 2/6.97(177) 2/6.97(177) 2/6.97(177) 2/6.97(177) - 36 / 34 / 32 38/36/34 40/38/35 42/39/36 43/41/39 Thermistor Thermistor Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) 0.275(7) 0.275(7) R10C 3R10C 3R,12C 3R,12C 3R,14C *10.2*17.7(880*260*450)" 34.6*10.2*17.7 (880*260*450) 46.4*11.7 *17.7 (1180*298*450) 46.4*11.7 *17.7 (1180*298*450) 48.43*41.57*26.77(1230*370*680) 35(77.2) 35(77.2) 38(83.8) 38(83.8) 70(154.3) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8(9.52) 1/2 (12.7) 5/8(15.88) 5/8(15.88) 5/8(15.88) 3/4(19.05) *13.4*23.0 (1135*340*585) 44.7*13.4*23.0 (1135*340*585) 56.5*14.8*23.0(1435*375*585) 56.5*14.8*23.0(1435*375*585) 58.3*18.1*31.9(1480*460*810) 120/ /252 95/191 95/191 50/110 Conversion Formula kcal/h = kw x 860 Btu/h = kw x 3412 cfm = m 3 /min x 35.3

66 3. Dimensional Drawings LMNC-BH/BG/BE, LMNH-BH/BG/BE A k B h i l j C E K J e f (G) a b c d H D F Note: 1. Pipe Specification(mm) Model 18k 24k, 30k, 36k 48k Liquid Ø 6.35 Ø 9.52 Gas Ø12.7 Ø15.88 Ø19.05 (Unit: mm) Model A B C D E F (G) H J K a b c d e f h i j k l LMNC18/246BHA0 LMNH18/246BHA LMNC30/366BGA0 LMNH30/366BGA LMNC486BEA0 LMNH486BEA Top view (unit: mm) Inspection hole (600X600) Control box Front view H Front 600 Suitable dimension "H" is necessary to get a slope to drain as figure Product Data 65

67 4. Wiring Diagrams 4.1 LMNC-BH/BG, LMNH-BH/BG CENTRAL CONTROL TELE CONTROL DRY CONTACT IN-PIPE. THERMISTOR REMOTE CONTROL OUT-PIPE. ROOM. THERMISTOR THERMISTOR A/CL UNIT PTC HEATER FLOAT S/W ZONE CONTROL CN-FLOAT CN-ZONE CN-CC CN-DISP CN-PIPE1 CN-REMO CN-PIPE2 CN-MOTOR CN-ROOM CN-AIRC CN-PTC CN-OUT FUSE CN-POWER CN-DPUMP VENTILATION E/HEATER RD GN/YL BL BR 1(L) 2(N) TO OUTDOOR UNIT RF-REMOTE CONTROL OPTION 3854A20419B 4.2 LMNC-BE, LMNH-BE TO OUTDOOR UNIT 1(L) 2(N) GN/YL BR BL RD COMP BR YL FUSE 250V10A INDOOR MOTOR OR RD BL BK GN/YL DRAIN PUMP BL BL ROOM SENSOR PIPE SENSOR FLOAT S/W TERMINAL BLOCK REMOTE CONTROL A/CL UNIT TELECONTROL/ CENTRAL CONTROL ZONE CONTROL CONNECTOR NUMBER CN-POWER CN-MOTOR CN-D/PUMP CN-DISP CN-FLOAT CN-ZONE CN-CC LOCATION AC POWER SUPPLY BLDC FAN MOTOR OUTPUT DRAIN PUMP OUTPUT RF-REMOTE CONTROL FLOAT SWITCH INUT ZONE CONTROL OUTPUT CENTRAL CONTROL OUTPUT CONNECTOR NUMBER CN-PIPE1 CN-PIPE2 CN-REMO CN-ROOM CN-AIRC CN-PTC CN-OUT LOCATION PIPE SENSOR DISCHAGE PIPE SENSOR REMOTE CONTROL ROOM SENSOR AIR CLEAN PTC HEATER VENTILATION /ELECTRIC HEATER 66 MPS(Multi Power System) Variable Multi

68 5. Piping Diagrams Heat Exchanger :Cooling :Heating Sirocco Fan lndoor unit : Thermistor Refrigerant pipe connection port diameter Model Gas Liquid [unit: mm(inch)] LMNC186BHA0 LMNH186BHA0 LMNC246BHA0 LMNH246BHA0 LMNC30/366BGA0 LMNH30/366BGA0 LMNC486BEA0 LMNH486BEA0 12.7(1/2) 15.88(5/8) 19.05(3/4) 6.35 (1/4) 9.52(3/8) 2004 Product Data 67

69 6. External Static Pressure & Air Flow 6.1 LMNC-BE, LMNH-BE Models Static Pressure(mmAq) Model Name Step CMM(CFM) CMM(CFM) CMM(CFM) CMM(CFM) CMM(CFM) CMM(CFM) CCMM(CFM) LMNC486BEA0 LMNH486BEA0 High 48.5(1,722) 46.5(1,642) 45(1,598) 43.5(1,544) 42(1,491) 40(1,420) *40(1,420) Med 43(1,527) 41.5(1,466) 39.5(1,402) 38(1,349) 36.5(1,296) 35(1,243) *35(1,243) Low 39(1,385) 37.5(1,324) 36(1,278) 34.5(1,225) 33(1,172) 31(1,101) *31(1,101) External static pressure given after substracting coil losses motor step factory installed. External static pressure can be higher than the maximum given in the table, but the unit faces the problem of freezing the coil. The assured range of air-conditioner is in the only shady part and in the other part, the specification of air-conditioner may differ with the above table. If the static pressure of air-conditioner is out of the shady part, please adjust the static pressure. * Change the connection of the indoor fan motor connector to increase the motor speed to obtain similar CFM at 15 mmaq Static Pressure as at 10 mmaq Static pressure. 68 MPS(Multi Power System) Variable Multi

70 7. E.S.P. Setting for Phase Control Motor 7.1 Ceiling Concealed Duct(LMNC-BH/BG, LMNH-BH/BG Model) (1) Open the rear cover of the wired remote-controller to set the mode. (2) Select one of three selectable modes as follows. Without Zone System 1. Position V-H, F-H: This position sets the maximum E.S.P as a default set. 2. Position V-L: This position sets the minimum E.S.P as a default set. With Zone System 1. Position V-H: Maximum E.S.P setting & Fan speed is varied according to the state of dampers by micom. 2. Position F-H: Maximum E.S.P setting & Fan speed doesn't vary according to the opening & Closing of dampers. 3. Position V-L: Minimum E.S.P setting & Fan speed is varied according to the state of dampers by micom. *Maximum: 18K/24K - 8mmAq, 30K/36K - 10mmAq Minimum: All-0mmAq (3) Move the slide switch to set position. TH R13H R12H OP5R16H OP4 CO1H V-H F-H V-L R14H OP3 OP2 OP1 R19H SW TH R11H REMO MAIN 2TH OP7 R18H R17H OP6 LO STAND HI R03S C070 R04S R01S R15H Slide switch for ceiling height SW HIGH R02S (4) Close the rear cover and check if it works normally. CAUTION Select the position after checking duct work and E.S.P of the unit. Maunfactured in the position F-H Product Data 69

71 7. E.S.P. Setting for Phase Control Motor How to Set E.S.P? Procedure of RPM change: Ex) External Static pressure is 4mmAq for Model Name LMNH246BHA0. To protect the unit, compressor is designed to be off during E.S.P. setting. 1 Push the "On/Off" button. The unit will start. AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Push the "Timer" and "Wind" button simultaneously for more then 3 seconds. Timer AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Push the "Up" of "Down" button for E.S.P adjustment. And, adjust the number which you want.(in this example, the number is "190". Refer to the table 7-1 on the next page.) AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Note: The range of selection is from 1~254. Since, the display is two Digit only. If the range selection is above 100 then the third digit will appear in the screen as shown. 4 Shift the fan speed mode by pressing the fan speed button. And then, Adjust numbers of next steps by repeating the stage 3. (In this example, the numbers are "220" and "235" respectively. 5 Push the "Timer" and "Wind" button simultaneously for more than 3 seconds. Then, Wind Data is memorized by the EEPROM of the main PCB. Timer AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time MPS(Multi Power System) Variable Multi

72 7. E.S.P. Setting for Phase Control Motor Table-7-1 Static Pressure(mmAq) Model Name LMNC186BHA0 LMNH186BHA0 LMNC246BHA0 LMNH246BHA0 LMNC306BGA0 LMNH306BGA0 LMNC366BGA0 LMNH366BGA0 Table-7-2 Static Pressure(mmAq) Model Name Step CMM(CFM) Step Setting Value Setting Value High 16.5 (583) Med 14.5 (512) Low 13.0 (459) High 18.0 (636) Med 16.5 (583) Low 14.0 (494) High 26.5(936) Med 23(812) Low 20(706) High 32.0(1130) Med 29.0(1024) Low 26.5(936) Note: 1. To get the desired Airflow & E.S.P combination from the table set the matching value from the table. Value other than that in table will not give the combinations of airflow & ESP which are mentioned in the table. 2. Table 7-1 is based at 230V. According to the fluctuation of voltage, air flow rate varies. LMNC186BHA0 LMNH186BHA0 LMNC246BHA0 LMNH246BHA0 LMNC306BGA0 LMNH306BGA0 LMNC366BGA0 LMNH366BGA CMM(CFM) CMM(CFM) CMM(CFM) CMM(CFM) CMM(CFM) CMM(CFM) High (777) 21.0 (742) 19.8 (699) 18.3 (646) 16.5 (583) Med (653) 17.8 (629) 17.1 (604) 16.2 (572) 14.5 (512) Low (569) 15.6 (551) 15.1 (533) 14.2 (501) 13.0 (459) High (848) 22.5 (795) 20.8 (735) 19.0 (671) 18.0 (636) Med (752) 19.9 (703) 18.7 (660) 17.2 (607) 16.5 (583) Low (600) 16.1 (569) (551) 14.7 (519) 14.0 (494) High (1208) 33.1(1169) 31.7(1119) 29.9(1056) 27.7( (936) Med (954) 26.3(929) 26.1(922) 25.8(911) 24.8(876) 23(812) Low (742) 20.8(735) 20.6(727) 20.4(720) 20.4(720) 20(706) High 1 42(1483) 40(1413) 38(1342) 35.5(1254) 33.5(1183) 32(1130) Med (1377) 37(1307) 35(1236) 33(1165) 31(1095) 29(1024) Low (1201) 32.5(1148) 31(1095) 29.5(1042) 27(954) 26.5(936) Note: 1. The above table shows the correlation of External Static Pressure & Air Flow. 2. Duct work must be desined within the shaded range of on installing the table. 3. If duct work is designed under External Static Pressure adjust the External Static Pressure applying air damper Product Data 71

73 8. Sound Levels Overall DISCHARGE DUCT 2m 1.5m SUCTION DUCT 1m 1m Notes: - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20µPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(ks conditions) Model LMNC/H186BHA0 LMNC/H246BHA0 Sound Levels(dBA) H M L Sound Pressure Level LMNC/H186BHA0 LMNC/H246BHA0 LMNC/H306BGA0 Model LMNC/H306BGA0 LMNC/H366BGA0 LMNC/H486BEA0 Sound Levels(dBA) H M L Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 NC NC-25 NC NC-25 NC NC Octave Band Center Frequency (Hz) LMNC/H366BGA NC Octave Band Center Frequency (Hz) 90 LMNC/H486BEA0 NC Octave Band Center Frequency (Hz) NC NC-70 Sound Pressure Level (db re 20µPa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 NC NC-25 NC-20 NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) 72 MPS(Multi Power System) Variable Multi

74 9. Installation Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Air outlet vents Air filters Air intake vents Wired LCD Remote Control Required Parts Required Tools Connecting cable Pipes: Gas side Liquid side Hanging Bolt (W 3/8 or M10 length 650mm) Insulated drain hose Additional Drain hose (Inner Dia mm) 9.1 Selection of the best location Install the air conditioner in the location that satisfies the following conditions. The place shall easily bear a load exceeding four times the indoor unit s weight. The place should have enough area for inspection as shown in figure. The place where the unit shall be leveled. The place shall allow easy water drainage.(suitable dimension H is necessary to get a slope to drain as figure.) The place shall easily connect with the outdoor unit. The place where the unit is not affected by an electrical noise. The place where air circulation in the room will be good. There should not be any heat source or steam near the unit. Level Screw driver Electric drill Hole core drill (ø70mm) Flaring Tools set Torque Wrenches Hexagonal Wrench (4mm, 5mm) Gas-leak detector Owner s Manual Thermometer Top view (unit: mm) 600 Front view Inspection hole (600X600) Control box 1000 Front H Product Data 73

75 9. Installation 9.2 Ceiling dimension and hanging bolt location Installation of Unit Install the unit above the ceiling correctly. A B CASE 1 C E POSITION OF SUSPENSION BOLT Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. Apply a filter Accessory at air return hole. Refer todimensinal Drawings. I H (G) 1-3 mm D F Drainage hole Install the unit leaning to a drainage hole side as a figure for easy water drainage. M10 Nut X 4 M10 SP. washer X 4 M10 washer X 4 (Local supply) CASE 2 M10 washer X 4 M10 SP. washer X 4 M10 Nut X 4 (Local supply) POSITION OF CONSOLE BOLT A place where the unit will be leveled and that can support the weight of the unit. A place where the unit can withstand its vibration. A place where service can be easily performed. NOTE: Throughly study the following installation locations: 1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc. In these cases, take the following actions: Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily steam which should not flow into the suction of the air conditioner. Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam. 2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc. 3. Avoid places where inflammable gas is generated, flows in, is stored or vented. 4. Avoid places where sulfurous acid gas or corrosive gas is generated. 5. Avoid places near high frequency generators. 74 MPS(Multi Power System) Variable Multi

76 9. Installation Select and mark the position for fixing bolts. Drill the hole for set anchor on the face of ceiling. Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. Mount the suspension bolts to the set anchor firmly. Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers. Old building New building CAUTION Tighten the nut and bolt to prevent unit falling. 1 Set anchor 2 Plate washer 3 Spring washer 4 Nut 5 Suspension bolts 9.3 Connecting Cables Connect the wires to the terminals on the control board individually according to the outdoor unit connection. Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively Terminal Block in Indoor 1(L) 2(N) 3 4 Connected to Outdoor Unit( or BD Unit) WARNING Make sure that the screws of the terminal are free from looseness. Clamping of cables 1) Arrange 2 power cables on the control panel. 2) First, fasten the steel clamp with a screw to the inner boss of control panel. 3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the 0.75mm 2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel. 4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin on the power plug should be over 1.8m Product Data 75

77 9. Installation 9.4 Insulation THERMAL INSULATION All thermal insulation must comply with local requirement. INDOOR UNIT Union for liquid pipe Refrigerant pipe and thermal insulator(local supply) Thermal insulator for refrigerant pipe (Local supply) Thermal insulator for piping(local supply) Union for gas pipe Hose crip for thermal insulator (Local supply) Thermal insulator for refrigerant pipe (Local supply) Overlap with thermal insulator for piping. Hose crip for thermal insulator(local supply) Make sure that there is no clearance here. 9.5 Checking the Drainage 1) Checking the Drainage 1. Remove the Air Filter. 2. Check the drainage. Spray one or two glasses of water on the evaporator. Ensure that water flows to drain hose from indoor unit without any leakage. 76 MPS(Multi Power System) Variable Multi

78 9. Installation CAUTION 1. Decline Installation of indoor unit is very important for the drain of the duct type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe should be 5mm. Front of view The unit must be or declined to wards drain hose while installation. Ceiling 1~3mm CORRECT Drainage hole INCORRECT Drainage hole CAUTION FOR GRADIENT OF UNIT AND DRAIN PIPING Alway lay the drain with downward inclination (1/50 to 1/100). Prevent any upward flow or reverse flow in any part. 5mm or thicker formed thermal insulator shall always be provided for the drain pipe. Lay the drain hose with a downware inclination so water will drain out. Unit Thermal insulator (Local supply) Drainage pipe (Local supply) Make sure to be closed. Drainage hole CORRECT Install the P-Trap (or U-Trap) to prevent a water leakage caused by the blocking of intake air filter. Drain Pipe MAX 700mm 1/50~1/100 INCORRECT Applied U-Trap Dimension A 70mm B 2C C 2 x SP SP = External Pressure (mmaq) Ex) External Pressure = 10mmAq A 70mm B 40mm C 20mm C A B U-Trap Drain Pump 2004 Product Data 77

79 10. Accessories Standard Accessories Name Clamp metal Drain hose Insulation for fitting Clamp Screws for duct flanges (Other) Quantity 1 EA 1 EA 1 set 6 EA 1 set Shape for gas pipe Owner's manual Installation manual Washers(8 pcs.) Optional Accessories(For Unit) for liquid pipe No. Item Type Model No. Component Parts 1 Wireless remote control With air purifying function AHWRHS AHWRHD(LCD) Wireless remote control : 1EA Holder : 1EA Battery : 2EA Screw : 2EA 2 Plasma air puirifying filter - ABPAHH Plasm Air Purifier Kit: 1EA Wired Remote Control: 1EA 3 Zone Control - ABZCA Factory sypplied-zone control PCB Durchased Locally-Damper, Damper Moter, thermostat 4 Drain Pump - ABDPG Drain Pump Assembly: 1EA HAND OVER Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature control, etc.). 78 MPS(Multi Power System) Variable Multi

80 LMNC-BT LMNH-BT 4. Ceiling Concealed Duct - Low Static Pressure 1. List of Functions Specifications Dimensional Drawings Wiring Diagrams Piping Diagrams E.S.P. Setting for Phase Control Motor Sound Levels Installation Accessories Product Data 79

81 1. List of Functions Features Model LMNC-BT, LMNH-BT Airflow Direction Control(Left & Right) - Airflow Direction Control(Up & Down) - Airflow Outlet 1 Airflow Steps(Fan / Cool / Heat) 3/3/3 Auto Changeover(Operation) - Auto Cleaning - Auto Restart Operation O Central Control Accessory CHAOS Wind(Auto Wind) - Child Lock Function O Cooling & Heating Fan Operation O Deice Control O Deodorizing Filter - Drain Pump Accessory E.S.P Control O Forced Operation O Group Control O High Ceiling Operation - Hot Start Function O Jet Cool - Plasma Air Purifying Filter - Plasma Heat Exchanger - Prefilter(Washable / Anti-fungus) O Self Diagnosis Function O Sleep Mode Operation - Soft Dry Operation O Soft Start Function - Test Function O Time Delay Safety Function O Timer(24 Hour, On/Off) O Timer(Weekly, On/Off) O Two Thermistor Control O Wired LCD Remote Control O Wireless LCD Remote Control Accessory Zero Stanby Power - Zone Control - Notes : O : Basic Optional : Factory-Installed Accessory : Field-Installed - : Not available on this system 80 TPS Inverter Multi

82 2. Specification Heat Pump Indoor Unit Type Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) External Static Pressure mmaq Setting temperature range (cool/heat) C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µf/vac Fan Type No. Used / Diameter EA/inch(mm) Noise Level(Sound Press,1m) H/M/L dba Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) Net Weight kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) Stuffing Quantity Without S/Parts 20/40ft Ceiling Concealed Duct - Low Static LMNH126BTG0 LMNH186BTG0 3024(3516) 4536(5274) (3516) 4536(5274) /9/8(352/317/282) 13.5/12/10(477/424/353) ~30 / 16~30 18~30 / 16~ YDK L YSK L / /370 Sirocco Fan Sirocco Fan 1/7.8(197) 2/7.8(197) 37/34/31 38/36/34 Thermistor Thermistor 0.276(7.0) 0.276(7.0) R,12C 2R, 12C *9.0*21.1(650*230*535) 39.4*9.0*21.1(1000*230*535) 22(48.5) 29(63.9) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7) 1/2 (12.7) *24.6*11.8(760*625*300) 29.9*24.6*11.8(760*625*300) 172/ /251 Cooling Only Indoor Unit Type Ceiling Concealed Duct - Low Static Model Nominal Cooling Capacity kcal/hr(w) Btu/hr Nominal Heating Capacity kcal/hr(w) Btu/hr Air Circulation H/M/L CMM(CFM) External Static Pressure mmaq Setting temperature range (cool/heat) C Fan motor Output W Model YDK L YSK L No. of Poles 4 4 Input W Running Current A Capacitor µf/vac 2.5/ /370 Fan Type Sirocco Fan Sirocco Fan No. Used / Diameter EA/inch(mm) 1/7.8(197) 2/7.8(197) Noise Level(Sound Press,1m) H/M/L dba 37/34/31 38/36/34 Temperature controller Thermistor Thermistor Coil Tube Size (OD) inch(mm) 0.276(7.0) 0.276(7.0) Fins per inch No. of Rows & Column 3R,12C 2R, 12C Dehumidification Rate l/h Dimensions (W*H*D) Indoor Unit inch(mm) 25.6*9.0*21.1(650*230*535) 39.4*9.0*21.1(1000*230*535) Net Weight kg(lbs) 22(48.5) 29(63.9) Piping Liquid inch(mm) 1/4 (6.35) 1/4 (6.35) Connection Gas inch(mm) 1/2 (12.7) 1/2 (12.7) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) 29.9*24.6*11.8(760*625*300) 29.9*24.6*11.8(760*625*300) Stuffing Quantity Without S/Parts 20/40ft 172/ /251 Notes:- 1. Capacities are based on the following conditions: Conversion Formula Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. kcal/h = kw x 860 Btu/h = kw x 3412 cfm = m 3 /min x 35.3 Heating: - Indoor Temperature 20 C(68 F) DB / 15 C(59 F) WB - Outdoor Temperature 7 C(44.6 F) DB / 6 C(42.8 F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. : See the page "Combination Table" LMNC126BTG0 LMNC186BTG0 3024(3516) 4536(5274) /9/8(352/317/282) 13.5/12/10(477/424/353) ~30 / 16~30 18~30 / 16~ Product Data 81

83 3. Dimensional Drawings LMNC-BT, LMNH-BT A B G H C E F D Dimension Capacity A B C D E F G H 12k k Note: 1. Pipe Specification(mm) Model 12k, 18k Liquid Ø 6.35 Gas Ø 12.7 (unit: mm) Top view (unit: mm) Inspection hole (600X600) Control box Front view Suitable dimension "H" is necessary to get a slope to drain as figure H 82 TPS Inverter Multi

84 4. Wiring Diagrams CENTRAL CONTROL TELE CONTROL DRY CONTACT IN-PIPE. THERMISTOR REMOTE CONTROL OUT-PIPE. THERMISTOR ROOM. THERMISTOR A/CL UNIT PTC HEATER FLOAT S/W ZONE CONTROL CN-FLOAT CN-ZONE CN-CC CN-DISP CN-PIPE1 CN-REMO CN-MOTOR CN-PIPE2 CN-ROOM CN-AIRC CN-PTC CN-OUT FUSE CN-POWER CN-DPUMP VENTILATION E/HEATER RD GN/YL BL BR 1(L) 2(N) TO OUTDOOR UNIT RF-REMOTE CONTROL OPTION 3854A20419A CONNECTOR NUMBER CN-POWER CN-MOTOR CN-D/PUMP CN-DISP CN-FLOAT CN-ZONE CN-CC CN-PIPE1 CN-PIPE2 CN-ROOM CN-REMO CN-AIRC CN-PTC CN-OUT LOCATION AC POWER SUPPLY BLDC FAN MOTOR OUTPUT DRAIN PUMP OUTPUT RF-REMOTE CONTROL FLOAT SWITCH INUT ZONE CONTROL OUTPUT CENTRAL CONTROL OUTPUT PIPE SENSOR DISCHAGE PIPE SENSOR ROOM SENSOR REMOTE CONTROL AIR CLEAN PTC HEATER VENTILATION/ELECTRIC HEATER 2004 Product Data 83

85 5. Piping Diagrams Heat Exchanger :Cooling :Heating Sirocco Fan lndoor unit : Thermistor Refrigerant pipe connection port diameter [unit: mm(inch)] Model Gas Liquid LMNC126BTG0 LMNH126BTG0 Ø12.7 (1/2) 6.35 (1/4) LMNC186BTG0 LMNH186BTG0 84 TPS Inverter Multi

86 6. E.S.P. Setting for Phase Control Motor 6.1 Ceiling Concealed Duct(LMNC-BT, LMNH-BT Model) (1) Open the rear cover of the wired remote-controller to set the mode. (2) Select one of three selectable modes as follows. Without Zone System 1. Position V-H, F-H: This position sets the maximum E.S.P as a default set. 2. Position V-L: This position sets the minimum E.S.P as a default set. With Zone System 1. Position V-H: Maximum E.S.P setting & Fan speed is varied according to the state of dampers by micom. 2. Position F-H: Maximum E.S.P setting & Fan speed doesn't vary according to the opening & Closing of dampers. 3. Position V-L: Minimum E.S.P setting & Fan speed is varied according to the state of dampers by micom. *Maximum: 12k/18k - 3mmAq Minimum: All-0mmAq (3) Move the slide switch to set position. TH R13H R12H OP5R16H OP4 CO1H V-H F-H V-L R14H OP3 OP2 OP1 R19H SW TH R11H REMO MAIN 2TH OP7 R18H R17H OP6 LO STAND HI R03S C070 R04S R01S R15H Slide switch for ceiling height SW HIGH R02S (4) Close the rear cover and check if it works normally. CAUTION Select the position after checking duct work and E.S.P of the unit. Maunfactured in the position F-H Product Data 85

87 6. E.S.P. Setting for Phase Control Motor How to Set E.S.P? Procedure of RPM change: Ex) External Static pressure is 1mmAq for Model Name "LMNH186BTG0". To protect the unit, compressor is designed to be off during E.S.P. setting. 1 Push the "On/Off" button. The unit will start. AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Push the "Timer" and "Wind" button simultaneously for more then 3 seconds. Timer AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Push the "Up" of "Down" button for E.S.P adjustment. And, adjust the number which you want.(in this example, the number is "150". Refer to the table 6-1) AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Note: The range of selection is from 1~254. Since, the display is two Digit only. If the range selection is above 100 then the third digit will appear in the screen as shown. 4 Shift the fan speed mode by pressing the fan speed button. And then, Adjust numbers of next steps by repeating the stage 3. (In this example, the numbers are "165" and "180" respectively. 5 Push the "Timer" and "Wind" button simultaneously for more than 3 seconds. Then, Wind Data is memorized by the EEPROM of the main PCB. Timer AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer On Off Operation unit Program set Set no. Time Table-6-1 Static Pressure(mmAq) Model Name Step(Hi/Med/Lo) Setting Value 10 CMM LMNC126BTG0 9 CMM LMNH126BTG0 8 CMM CMM LMNC186BTG0 13 CMM LMNH186BTG0 12 CMM TPS Inverter Multi

88 7. Sound Levels Overall 2.0m 1.5m Ceiling Notes: - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20µPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(ks conditions) Microphone Model Sound Levels(dBA) H M L LMNC/H126BTG LMNC/H186BTG Sound Pressure Level LMNC/H126BTG0 LMNC/H186BTG NC-70 NC-70 Sound Pressure Level (db re 20µPa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Sound Pressure Level (db re 20µPa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC NC-25 NC-20 NC-20 NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) 2004 Product Data 87

89 8. Installation Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Air intake vents Remote Controller Air intake vents Air filters Required Parts Required Tools Connecting cable Pipes: Gas side Liquid side Hanging Bolt (W 3/8 or M10 length 650mm) Insulated drain hose Additional Drain hose (Inner Dia mm) 8.1 Selection of the best location Install the air conditioner in the location that satisfies the following conditions. The place shall easily bear a load exceeding four times the indoor unit s weight. The place shall be able to inspect the unit as the figure. The place where the unit shall be leveled. The place shall allow easy water drainage.(suitable dimension H is necessary to get a slope to drain as figure.) The place shall easily connect with the outdoor unit. The place where the unit is not affected by an electrical noise. The place where air circulation in the room will be good. There should not be any heat source or steam near the unit. Level Screw driver Electric drill Hole core drill (ø70mm) Flaring Tools set Torque Wrenches Hexagonal Wrench (4mm, 5mm) Gas-leak detector Owner s Manual Thermometer Top view (unit: mm) Front view 600 Inspection hole (600X600) Control box H TPS Inverter Multi

90 8. Installation 8.2 Ceiling dimension and hanging bolt location Installation of Unit Install the unit above the ceiling correctly. A B CASE 1 POSITION OF SUSPENSION BOLT C E D Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. (Unit:mm) Dimension Capacity A B C D E F G H (Btu/h) 12k k G H F Drainage hole 1-3 mm M10 Nut X 4 M10 SP. washer X 4 M10 washer X 4 (Local supply) Install the unit leaning to a drainage hole side as a figure for easy water drainage. CASE 2 M10 washer X 4 M10 SP. washer X 4 M10 Nut X 4 (Local supply) POSITION OF CONSOLE BOLT A place where the unit will be leveled and that can support the weight of the unit. A place where the unit can withstand its vibration. A place where service can be easily performed. NOTE: Throughly study the following installation locations: 1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc. In these cases, take the following actions: Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily steam which should not flow into the suction of the air conditioner. Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam. 2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc. 3. Avoid places where inflammable gas is generated, flows in, is stored or vented. 4. Avoid places where sulfurous acid gas or corrosive gas is generated. 5. Avoid places near high frequency generators Product Data 89

91 8. Installation Select and mark the position for fixing bolts. Drill the hole for set anchor on the face of ceiling. Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. Mount the suspension bolts to the set anchor firmly. Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers. Old building New building CAUTION Tighten the nut and bolt to prevent unit falling. 1 Set anchor 2 Plate washer 3 Spring washer 4 Nut 5 Suspension bolts 8.3 Connecting Cables Connect the wires to the terminals on the control board individually according to the outdoor unit connection. Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively Terminal Block in Indoor 1(L) 2(N) 3 4 Connected to Outdoor Unit( or BD Unit) Clamping of cables 1) Arrange 2 power cables on the control panel. 2) First, fasten the steel clamp with a screw to the inner boss of control panel. 3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the 0.75mm 2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel. 4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin on the power plug should be over 1.8m. 8.4 Insulation Union for liquid pipe Refrigerant pipe and thermal insulator(local supply) Thermal insulator for refrigerant pipe (Local supply) Thermal insulator for piping(local supply) Hose clip for thermal insulator (Local supply) Thermal insulator for refrigerant pipe (Local supply) Union for gas pipe Overlap with thermal insulator for piping. Hose clip for thermal insulator(local supply) Make sure that there is no clearance here. 90 TPS Inverter Multi

92 8. Installation 8.5 Checking the Drainage Spray one or two glasses of water upon the evaporator. Ensure that water flows drain hose of indoor unit without any leakage. CAUTION 1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe shall be 5mm. Front of view The unit must be horizontal or declined to the drain hose connected when finished installation. Ceiling 1~3mm CORRECT Drainage hole INCORRECT Drainage hole CAUTION FOR GRADIENT OF UNIT AND DRAIN PIPING Always lay the drain with downward inclination (1/50 to 1/100). Prevent any upward flow or reverse flow in any part. 5mm or thicker formed thermal insulator shall always be provided for the drain pipe. Lay the drain hose with a downward inclination so water will drain out. Unit Make sure to be closed. Thermal insulator (Local supply) Drainage pipe (Local supply) Drainage hole Upward routing not allowed INCORRECT CORRECT Install the P-Trap (or U-Trap) to prevent a water leakage caused by the blocking of intake air filter. Applied U-Trap Dimension A 70mm B 2C C 2 x SP SP = External Pressure (mmaq) Ex) External Pressure = 10mmAq A 70mm B 40mm C 20mm C A B U-Trap 2004 Product Data 91

93 9. Accessories Standard Accessories Name Clamp metal Insulation for fitting Screws for duct flanges Clamp (Other) Quantity 1 EA 1 set 1 set 8 EA Owner's manual Installation manual Shape for gas pipe for liquid pipe Optional Accessories(For Unit) No. Item Type Model No. Component Parts 1 Wireless remote control With air purifying function AHWRHD Wireless remote control : 1EA Holder : 1EA Battery : 2EA Screw : 2EA 2 Drain Pump ABDPG Drain Pump assembly: 1EA 92 TPS Inverter Multi

94 Part 3 Outdoor Units MPS Variable Multi 1. Power Supply Specifications Combination Table Dimensional Drawings Wiring Diagrams Piping Diagrams Capacity Tables Capacity Coefficient Factor Operation Limit Sound Levels Installation Accessories Product Data 93

95 1. Power Supply Type Outdoor Unit Power Supply Heat Pump L8UH1008FA0 L4UC608FA0 3Ø, V, 50Hz Cooling Only L5UC728FA0 L8UC1008FA0 Note : Power Supply Intake ; Outdoor Unit Only External wiring procedure - The power supply work is needed only to the outdoor unit. The power supply to the BD unit and the indoor unit is conducted through the transmission wiring. Therefore, the power supply work can be carried out at just one place of the outdoor unit. It will contribute to simplify the work procedure and to save cost. Power Supply Intake ; 3Ø, V, 50Hz 1) Direct Piping Type (100k Btu/h model shown) Power source [Indoor Unit] Circuit Breaker 60k: 25A 72k, 100k : 30A [Outdoor Unit] Earth Wire 2) Distributor Piping Type (100k Btu/h model shown) [Indoor Unit] BD Unit Power source Circuit Breaker 60k: 25A 72k, 100k : 30A [Outdoor Unit] BD Unit Earth Wire 94 MPS(Multi Power System) Variable Multi

96 2. Specifications 2.1 Outdoor Unit Model Btu/h Cooling Capacity W kcal/h Btu/h Heating Capacity W kcal/h Input Cooling/Heating W Running Current Cooling/Heating A Starting Current Cooling/Heating A Power Supply Ø,V,Hz Power Factor % Locked Rotor Amp. A Type Quantity No Model Compressor A+B Maker (MPS Cycle 1) Capacity kcal/h(btu/h) Motor Type Motor Input W Oil Type Oil Charge cc O.L.P Type(model name) Locked Rotor Amp. A Type Quantity No Model Compressor C Maker (MPS Cycle 2) Capacity kcal/h(btu/h) Motor Type Motor Input W Oil Type Oil Charge cc O.L.P Type(model name) Charge g(oz) Refrigerant charge Type Control Tube Size (OD) inch(mm) Coil Fins per inch No. of Rows & Column/No. Output W Model Fan Motor No. of Poles Input Running Current A Capacitor µf/vac Type Fan No. Used / Diameter EA/inch(mm) Discharge Side / Top Speed rpm Air Circulation Outdoor CMM(CFM) Noise Level(Sound Press,1m) db(a)±1 Liquid(Circuit 1) inch(mm) SVC Valve Gas(Circuit 1) inch(mm) Liquid(Circuit 2) inch(mm) Gas(Circuit 2) inch(mm) Drain(ID Ø) mm Dimensions W*H*D inch(mm) Net Weight Outdoor kg(lbs) Power Supply Cable No.* mm 2 Interunit Cable No.* mm 2 Total Piping m Max. Interunit Total Main Piping m Piping Length Total Branch Piping m For One Room m Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Packing Dimension W*H*D inch(mm) Stuffing Quantity With(Without) S/Parts 20/40ft L4UC608FA0 L5UC728FA ~ ~ ~ ~ ~ ~ ~6100 /- 1300~6600 /- 3.4~10.0/3.4~ ~11.0/3.4~ ,380~415,50 3,380~415,50 90~91 90~ Rotary Rotary Rotary QP325Y QP425Y QP425Y LG LG LG 4776(18950) 6212(24650) 6212(24650) Three Phase Induction Motor Three Phase Induction Motor ATMOS M60/SUNISO 4GSI ATMOS M60/SUNISO 4GSI Internal Internal Rotary Rotary 1 1 QP425Y QP425Y LG LG 6212(24650) 6212(24650) Three Phase Induction Motor Three Phase Induction Motor ATMOS M60/SUNISO 4GSI ATMOS M60/SUNISO 4GSI Internal Internal Cycle 1: 2100(74.1), Cycle 2: 1900(67.0) Cycle 1: 3800(134.0), Cycle 2: 1900(67.0) R22 R22 L.E.V & Short Tube L.E.V & Short Tube 0.276(Ø7.0) 0.276(Ø7.0) R,36C 2R,17C/2 : 2R,36C/ AMR250E** ARE676E /400 10/370 Axial FAN Axial FAN 1/Ø526 1/Ø526 Top Discharge Top Discharge (3002) 90(3179) /4(6.35) 3/8(9.52) 5/8(15.88) 3/4(19.05) 1/4(6.35) 1/4(6.35) 5/8(15.88) 5/8(15.88) *32.6*27.1(711*828*686) 31.7*59.5*28.7 (806*1512*730) 130(287) 160(353) 5*3.5(Includes earth) 5*3.5(Includes earth) 4*0.75(Includes earth) 4*0.75(Includes earth) 30(Direct piping) / 50(Distributor piping) 30(Direct piping) / 60(Distributor piping) 25(Distributor piping) 30(Distributor piping) 25(Distributor piping) 30(Distributor piping) *35.0*30.1(850*890*765) 33.9*61.0*28.7 (860*1550*730) 40/84 20/42 Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB Heating: - Indoor Temperature 20 C(68 F) DB / 15 C(59 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Outdoor Temperature 7 C(44.6 F) DB / 6 C(42.8 F) WB Piping Length - Main Piping Length 5m(Distributor piping) - Branch Piping Length 5m(Distributor piping) - Interconnecting Piping Length 7.5 m(direct piping) - Level Difference of Zero. 2. Capacities are Net Capacities. 3. : See Page "Combination Table" 4. Due to our policy of innovation some specifications may be changed without notification Product Data 95

97 2. Specifications Model Btu/h Cooling Capacity W kcal/h Btu/h Heating Capacity W kcal/h Input Cooling/Heating W Running Current Cooling/Heating A Starting Current Cooling/Heating A Power Supply Ø,V,Hz Power Factor % Locked Rotor Amp. A Type Quantity No Model Compressor A+B Maker (MPS Cycle 1) Capacity kcal/h(btu/h) Motor Type Motor Input W Oil Type Oil Charge cc O.L.P Type(model name) Locked Rotor Amp. A Type Quantity No Model Compressor C+D Maker (MPS Cycle 2) Capacity kcal/h(btu/h) Motor Type Motor Input W Oil Type Oil Charge cc O.L.P Type(model name) Charge g(oz) Refrigerant charge Type Control Tube Size (OD) inch(mm) Coil Fins per inch No. of Rows & Column/No. Output W Model Fan Motor No. of Poles Input Running Current A Capacitor µf/vac Type Fan No. Used / Diameter EA/inch(mm) Discharge Side / Top Speed rpm Air Circulation Outdoor CMM(CFM) Noise Level(Sound Press,1m) db(a)±1 SVC Valve Liquid inch(mm) Gas inch(mm) Drain(ID Ø) mm Dimensions W*H*D inch(mm) Net Weight Outdoor kg(lbs) Power Supply Cable No.* mm 2 Interunit Cable No.* mm 2 Total Piping m Max. Interunit Total Main Piping m Piping Length Total Branch Piping m For One Room m Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Packing Dimension W*H*D inch(mm) Stuffing Quantity With(Without) S/Parts 20/40ft L8UC1008FA0 L8UH1008FA ~ ~ ~ ~ ~ ~ ~ ~ ~ ~9500 /- 1300~9500 /1300~ ~15.2/- 3.4~15.2/3.4~ ,380~415,50 3,380~415,50 90~92 90~ Rotary Rotary 2 2 QP425Y QP425Y LG LG 6212(24650) 6212(24650) Three Phase Induction Motor Three Phase Induction Motor ATMOS M60/SUNISO 4GSI ATMOS M60/SUNISO 4GSI Internal Internal Rotary Rotary 2 2 QP425Y QP425Y LG LG 6212(24650) 6212(24650) Three Phase Induction Motor Three Phase Induction Motor ATMOS M60/SUNISO 4GSI ATMOS M60/SUNISO 4GSI Internal Internal 4000(141.1) / Circuit(Standard piping length) 4000(141.1) / Circuit(Standard piping length) R22 R22 L.E.V & Short Tube L.E.V & Short Tube 0.375(Ø9.52) 0.375(Ø9.52) R,14C/2 : 1R,30C/2 2R,14C/2 : 1R,30C/2 400*2 400*2 ARE676E01 ARE676E *2 270*2 1.8*2 1.8*2 10/370 10/370 Axial FAN Axial FAN 2/Ø526 2/Ø526 Top Discharge Top Discharge (6357) 180(6357) /8(9.52)*2EA 3/8(9.52)*2EA 3/4(19.05)*2EA 3/4(19.05)*2EA *59.8*28.7(1280*1520*730) 50.4*59.8*28.7(1280*1520*730) 250(551) 250(551) 4*3.5 4*5.5 4*0.75(Includes earth) 4*0.75(Includes earth) 50(Direct piping) / 60(Distributor piping) 50(Direct piping) / 60(Distributor piping) 30(Distributor piping) 30(Distributor piping) 30(Distributor piping) 30(Distributor piping) *61.0*29.3(1320*1550*745) 52.0*61.0*29.3(1320*1550*745) 12/27 12/27 Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27 C(80.6 F) DB /19 C(66.2 F) WB Heating: - Indoor Temperature 20 C(68 F) DB / 15 C(59 F) WB - Outdoor Temperature 35 C(95 F) DB /24 C(75.2 F) WB - Outdoor Temperature 7 C(44.6 F) DB / 6 C(42.8 F) WB Piping Length - Main Piping Length 5m(Distributor piping) - Branch Piping Length 5m(Distributor piping) - Interconnecting Piping Length 7.5 m(direct piping) - Level Difference of Zero. 2. Capacities are Net Capacities. 3. : See Page "Combination Table" 4. Due to our policy of innovation some specifications may be changed without notification. 96 MPS(Multi Power System) Variable Multi

98 2. Specifications 2.2 BD Unit Model Connectable Indoor Units Combination(Min~Max.) Btu/h Casing color Powre Source Power Consumption W Runing Current A Dimensions W*H*D inch(mm) Packing Dimension W*H*D inch(mm) Net Weight kg Connecting Cable Direction Indoor Unit No. * mm 2 Direction Outdoor Unit No. * mm 2 Piping Conntcion Liquid inch(mm) (To Outdoor Unit) Gas inch(mm) Piping Conntcion Liquid inch(mm) (To Indoor Unit) Gas inch(mm) Piping Length m Piping Elevation m Drain hose Heat Insulation Accessories Hanger EA Screw EA Connector EA Manual EA PMBD5440L PMBD5430L PMBD5420L 1~4 1~3 1~ ~ ~ ~54000 Paintingless Paintingless Paintingless Ø1, 50/60Hz,220~240/220V Ø1, 50/60Hz,220~240/220V Ø1, 50/60Hz,220~240/220V *5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) *0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/4(19.05) 3/4(19.05) 3/4(19.05) 1/4 (6.35)*4 1/4 (6.35)*3 1/4 (6.35)*2 1/2 (12.7)*4 1/2 (12.7)*3 1/2 (12.7)* Unusable Both Liquid and Gas pipes Note : 1. BD unit BD unit, Indoor Unit Indoor Unit : Max. Height - 10m Set up the BD unit and Indoor Unit in 15m. 2. The piping connection must be suit the piping sizes of the indoor unit which will be connected. (If need, use the connector which is included in the indoor unit) 3. The BD unit should be installed inside the building Product Data 97

99 3. Combination Table 3.1 L4UC608FA0 Cooling Combination of Indoor unit Cooling Operation (k Btu/h) Each Capacity Circuit Unit Unit-A Unit-B Unit-C Unit-D Total Unit-A Unit-B Unit-C Unit-D Total 1 2 1Unit Unit Unit Unit Notes: 1. Cooling Capacity is based on : indoor temp.27 C(80.6 F) DB, 19 C(66.2 F) WB; outdoor temp. 35 C(95 F) DB 2. The total capacity of indoor unit of "Circuit 1" is up to Btu/h (10.6kW). The total capacity of indoor unit of "Circuit 2" is up to Btu/h (7.1kW). 3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 5m (16.4ft)] Input (W) Current (A) 3.2 L5UC728FA0 Cooling Combination of Indoor unit Cooling Operation (k Btu/h) Each Capacity Circuit Unit Unit-A Unit-B Unit-C Unit-D Total Unit-A Unit-B Unit-C Unit-D Total 1 2 1Unit Unit Unit Unit Unit Notes: 1. Cooling Capacity is based on : indoor temp.27 C(80.6 F) DB, 19 C(66.2 F) WB; outdoor temp. 35 C(95 F) DB 2. The total capacity of indoor unit of "Circuit 1" is up to Btu/h (15.8kW). The total capacity of indoor unit of "Circuit 2" is up to Btu/h (7.1kW). 3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 5m (16.4ft)] Input (W) Current (A) 98 MPS(Multi Power System) Variable Multi

100 3. Combination Table 3.3 L8UC1008FA0/L8UH1008FA0 Cooling Combination of Indoor unit Cooling Operation (k Btu/h) Each Capacity Circuit Unit Unit-A Unit-B Unit-C Unit-D Total Unit-A Unit-B Unit-C Unit-D Total 1 or 2 1 Unit Unit Unit Unit Input (W) Current (A) Heating Combination of Indoor unit Heating Operation (k Btu/h) Each Capacity Circuit Unit Unit-A Unit-B Unit-C Unit-D Total Unit-A Unit-B Unit-C Unit-D Total 1 or 2 1 Unit Unit Unit Unit Notes: 1. Cooling Capacity is based on : indoor temp.27 C(80.6 F) DB, 19 C(66.2 F) WB; outdoor temp. 35 C(95 F) DB 2. Heating Capacity is based on : indoor temp.20 C(60 F) DB; outdoor temp. 7 C(44.6 F) DB, 6 C(42.8 F) WB 3. The total capacity of indoor unit is up to Btu/h (15.8kW) per circuit. 4. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 5m (16.4ft)] Input (W) Current (A) 2004 Product Data 99

101 4. Dimensional Drawings 4.1 Outdoor Unit L4UC608FA0 H W D (unit : mm) Model L4UC608FA0 Dimension W 711 H 828 D 687 Number Name Descripition 1 Liquid side service valve(mm) Ø6.35 x 2EA 2 Gas side service valve(mm) Ø15.88 x 2EA 3 Control Cover 4 Air discharge grill 5 Air inlet 100 MPS(Multi Power System) Variable Multi

102 4. Dimensional Drawings L5UC728FA (bolt hole) (bolt hole) Air outlet Air inlet Air inlet Service Panel Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe) 220 Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe) 28 (Unit : mm) 2004 Product Data 101

103 4. Dimensional Drawings L8UC1008FA0/L8UH1008FA0 L4 L6 H L1 L 7 D L2 L3 W L8 D Model Dimensions L8UC1008FA0, L8UH1008FA0 W mm 1,280 H mm 1,520 D mm 730 L1 mm 1,444 L2 mm 700 L3 mm 690 L4 mm 900 L5 mm 10 L6 mm 670 L7 mm 48 L8 mm MPS(Multi Power System) Variable Multi

104 4. Dimensional Drawings 4.2 BD Unit PMBD5420L, PMBD5430L, PMBD5440L Ø12.7 flare Ø6.35 flare (Unit: mm) (298) 250 Ø9.52 flare (337) Ø19.05 flare Suspension bolt pitch. 245 Main Pipe (36) (38) (56) (150) (111) Branch Pipe Cover Control Min 400 Min 30 (Servicing space) Min 400 Min 300 Inspection opening 2004 Product Data 103

105 5.1 Outdoor Unit L4UC608FA0 5. Wiring Diagrams OUTDOOR WIRING DIAGRAM MAGNETIC CONTACTOR BK U WH V W RD COMP(A) LEV RD WH BK MAGNETIC CONTACTOR BK U WH V W RD COMP(B) RD WH BK CN-LEV-SINGLE (BL) MAIN PCB ASSY 1 3 (RD) CN-COMP BL RD BR (COMP-S)CN-FAN1(4WAY-S) (WH) MAGNETIC CONTACTOR BK U V W COMP(C) WH RD CN-FAN2 (WH) BK BL BR YL OR FMo (WH) CN_POWER CN_COM (WH) FUSE 250V T3.15A (WH) CN_TH1 CN_TH2 (YL) (RD) (PIPE S,DISCHARGE) (OUT(AIR)) BK BR BL OR RD WH RD BK BL BK GN/YL GN/YL OR BR BR BR BL OR TB1 HP LP R S T N 1(L) 2(N) 3(A) 1(L) 2(N) 3(B) GN/YL Main Power V3N~50Hz TO INDOOR UNIT-A (DISTRIBUTOR) TO INDOOR UNIT-B NOTE LEV FMo COMP BK BR BL LINEAR EXPANSION VALVE FAN MOTOR COMPRESSOR BLACK BROWN BLUE CN/YL OR RD WH YL GREEN & YELLOW ORANGE RED WHITE YELLOW 3854A20392H 104 MPS(Multi Power System) Variable Multi

106 5. Wiring Diagrams L5UC728FA0 OUTDOOR WIRING DIAGRAM BK WH RD CN_COMP CN_3PHASE RD U V W COMP (C) U V W COMP (B) MAGNETIC CONTACTOR BK WH RD MAGNETIC CONTACTOR BK WH RD MAIN PCB CN_FAN1 CN_4,S YL RD BL TB2 BL BL BK BK BK BK OR BL BK BR YL OR BL BK BR YL FAN1 SV Solenoid Valve2 SV Solenoid Valve1 WH RD WH BK RD WH BK BK U V W COMP (A) MAGNETIC CONTACTOR BK WH RD BL CN_COM CN_POWER CN_TH1 CN_PRESS CN_TH2 CN_TH3 BK WH BK BR BL WH (AIR/PIPE A,B) (PIPE C,D/COMP A,B) (COMP C,D) RD BL BL BR BL BR BR R S T N 3(L) 4(N) 5(A) 3(L) 4(N) 5(B) GN/YL Main Power A ROOM B ROOM TO INDOOR UNIT (DISTRIBUTOR) NOTE LEV FMo COMP BK BR BL LINEAR EXPANSION VALVE FAN MOTOR COMPRESSOR BLACK BROWN BLUE CN/YL OR RD WH YL GREEN & YELLOW ORANGE RED WHITE YELLOW 2004 Product Data 105

107 5. Wiring Diagrams L8UH1008FA0 OUTDOOR WIRING DIAGRAM U V W COMP (D) MAGNETIC CONTACTOR BK WH RD BL BK WH RD BL RELAY BR WH RD U V W COMP (C) U V W COMP (B) MAGNETIC CONTACTOR BK WH RD MAGNETIC CONTACTOR BK WH RD RD WH BK CN_COMP CN_3PHASE MAIN PCB CN_FAN2 CN_FAN1 CN_4,S BK YL RD WH BK BL TB1 TB2 BL BL BL BL BK BK BK BK OR BL BK BR YL OR BL BK BR YL OR BL BK BR YL OR BL BK BR YL FAN2 FAN1 SV Solenoid Valve2 SV Solenoid Valve1 BK BK 4WV 4Way Valve2 BK BK 4WV 4Way Valve1 RD WH BK RD WH BK CN_PRESS BK U V W COMP (A) MAGNETIC CONTACTOR BK WH RD BL CN_COM CN_POWER CN_TH1 CN_TH2 CN_TH3 BK WH BK BR BL WH (AIR/PIPE A,B) (PIPE C,D/COMP A,B) (COMP C,D) RD BL BL BR BL BR BR R S T N 3(L) 4(N) 5(A) 3(L) 4(N) 5(B) GN/YL Main Power A ROOM B ROOM TO INDOOR UNIT (DISTRIBUTOR) 3854A20354S 106 MPS(Multi Power System) Variable Multi

108 5. Wiring Diagrams L8UC1008FA0 OUTDOOR WIRING DIAGRAM U V W COMP (D) MAGNETIC CONTACTOR BK WH RD BL BK WH RD BL RELAY BR RD MAGNETIC CONTACTOR BK U WH V W RD COMP (C) MAGNETIC CONTACTOR BK U WH V W RD COMP (B) RD WH BK CN_COMP CN_3PHASE MAIN PCB CN_FAN2 CN_FAN1 CN_4,S BK YL RD BL TB1 TB2 BL BK BK OR BL BK BR YL OR BL BK BR YL OR BL BK BR YL OR BL BK BR YL FAN2 FAN1 SV Solenoid Valve2 BK BL BK SV Solenoid Valve1 WH RD WH BK RD WH BK CN_PRESS BK U V W COMP (A) MAGNETIC CONTACTOR BK WH RD BL CN_COM CN_POWER CN_TH1 CN_TH2 CN_TH3 BK WH BK BR BL WH (AIR/PIPE A,B) (PIPE C,D/COMP A,B) (COMP C,D) RD BL BL BR BL BR BR R S T N 3(L) 4(N) 5(A) 3(L) 4(N) 5(B) GN/YL Main Power V3N~50Hz A ROOM B ROOM TO INDOOR UNIT (DISTRIBUTOR) 3854A20354V 2004 Product Data 107

109 5. Wiring Diagrams 5.2 BD Unit PMBD5420L, PMBD5430L, PMBD5440L WIRING DIAGRAM CN_JIG3 CN_JIG2 LED1 LED2 LED3 LED4 PCB PARTS LAYOUT CN_JIG1 FUSE_2 FUSE_3 FUSE_4 FUSE_5 FUSE_1 CN_LEV_A CN_LEV_B CN_LEV_C CN_LEV_D CN_ROOM_A CN_ROOM_B CN_ROOM_C CN_ROOM_D CN_PWR S N L S N L S N L S N L S N L LEV A LEV B LEV C LEV D A B C D OUTDOOR TROUBLE DIAGNOSIS TO INDOOR UNIT FROM OUTDOOR UNIT LED DIAGNOSIS NORMAL ABNORMALITY -->CHECK BRANCH DISTRIBUTOR UNIT ABNORMALITY -->CHECK INDOOR OR OUTDOOR UNIT CHECK CONNECTING CABLE 3854A22003A Notes; 1. 'PMBD5420L' unit : "A,B" parts available. 2. 'PMBD5430L' unit : "A,B,C" parts available. 3. 'PMBD5440L' unit : "A, B, C, D" parts available. 108 MPS(Multi Power System) Variable Multi

110 6. Piping Diagrams 6.1 Outdoor Unit L4UC608FA0 OUTDOOR UNIT Field Piping Gas (Ø15.88) Field Piping Liquid (Ø6.35) Check Valve Check Valve Heat Exchanger Accumulator Compressor A Compressor B Field Piping Gas (Ø15.88) Field Piping Liquid (Ø6.35) LEV Heat Exchanger Compressor C Refrigerant Flow Cooling 2004 Product Data 109

111 6. Piping Diagrams L5UC728FA0 OUTDOOR UNIT Field Piping Gas (Ø19.05) Field Piping Liquid (Ø9.52) Check Valve Check Valve Heat Exchanger Accumulator Compressor A Compressor B Field Piping Gas (Ø15.88) Field Piping Liquid (Ø6.35) LEV Heat Exchanger Compressor C Refrigerant Flow Cooling 110 MPS(Multi Power System) Variable Multi

112 6. Piping Diagrams L8UC1008FA0 OUTDOOR UNIT Field Piping Gas (Ø19.05) Field Piping Liquid (Ø9.52) Check Valve Check Valve Heat Exchanger Accumulator Compressor A Compressor B Field Piping Gas (Ø19.05) Field Piping Liquid (Ø9.52) Check Valve Check Valve Heat Exchanger Accumulator Compressor C Compressor D Refrigerant Flow Cooling 2004 Product Data 111

113 6. Piping Diagrams L8UH1008FA0 OUTDOOR UNIT Reversing Valve Field Piping Gas (Ø19.05) Field Piping Liquid (Ø9.52) LEV Check Valve Check Valve Heat Exchanger Accumulator Compressor A Compressor B Field Piping Gas (Ø19.05) Field Piping Liquid (Ø9.52) LEV Check Valve Check Valve Heat Exchanger Accumulator Compressor C Compressor D Refrigerant Flow Cooling Heating 112 MPS(Multi Power System) Variable Multi

114 6. Piping Diagrams 6.2 BD Unit Refrigerant Flow Cooling Heating Ø19.05 Main Gas Piping Outdoor Unit D Gas C Gas Ø12.7 Ø12.7 LEV-A Ø9.52 Main Liquid Piping B Gas A Gas Ø12.7 Ø12.7 LEV-B LEV-C Indoor Unit LEV-D D Liquid C Liquid B Liquid A Liquid Ø6.35 Ø6.35 Ø6.35 Ø6.35 (Unit : mm) Notes; 1. Flare connection for the field piping connection 2. Adjust to indoor unit and outdoor unit piping size. Use the connector if the pipe size is not matched when connecting indoor unit. 3. L.E.V.: Linear Expansion Valve 4. PMBD5420L : A, B PMBD5430L : A, B, C PMBD5440L : A, B, C, D 2004 Product Data 113

115 7. Capacity Table 7.1 L4UC608FA0 [Cooling Capacity(English Unit)] Circuit 1 2 Combination Capacity Index (kbtu/h) Outdoor Air Temp.: FDB Indoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Notes: 1. All capacities are net, indoor fan motor heat is deducted. 2. Capacities are based on the following conditions. Corresponding refrigerant piping length : Direct piping - 25ft Distributor piping ft(Main) + 25ft(Branch) Level difference : 0 ft 3. TC : Total Cooling Capacity(1,000 Btu/h) 4. PI : Power Input(kW) 114 MPS(Multi Power System) Variable Multi

116 7. Capacity Table 7.2 L5UC728FA0 [Cooling Capacity(English Unit)] Circuit 1 Combination Capacity Index (kbtu/h) Outdoor Air Temp.: FDB Indoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Product Data 115

117 7. Capacity Table Circuit 1 2 Combination Capacity Index (kbtu/h) Outdoor Air Temp.: FDB Indoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Notes: 1. All capacities are net, indoor fan motor heat is deducted. 2. Capacities are based on the following conditions. Corresponding refrigerant piping length : Direct piping - 25ft Distributor piping -16.4ft(Main) + 25ft(Branch) Level difference : 0 ft 3. TC : Total Cooling Capacity(1,000 Btu/h) 4. PI : Power Input(kW) 116 MPS(Multi Power System) Variable Multi

118 7. Capacity Table 7.3 L8UC1008FA0/L8UH1008FA0 [Cooling Capacity(English Unit)] Combination Capacity Index (kbtu/h) Outdoor Air Temp.: FDB Indoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Product Data 117

119 7. Capacity Table Combination Capacity Index (kbtu/h) Outdoor Air Temp.: FDB Indoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Notes: 1. All capacities are net, indoor fan motor heat is deducted. 2. Capacities are based on the following conditions. Corresponding refrigerant piping length : Direct piping - 25ft Distributor piping -16.4ft(Main) + 25ft(Branch) Level difference : 0 ft 3. TC : Total Cooling Capacity(1,000 Btu/h) 4. PI : Power Input(kW) 5. This table is the capacity of circuit 1. Circut 2 is same. 118 MPS(Multi Power System) Variable Multi

120 7. Capacity Table [Heating Capacity(English Unit)] Combination Capacity Index (kbtu/h) Indoor Air Temp.: FDB Outdoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Product Data 119

121 7. Capacity Table Combination Capacity Index (kbtu/h) Indoor Air Temp.: FDB Outdoor Air Temp.: FWB TC PI TC PI TC PI TC PI TC PI TC PI Notes : 1. All capacities are net, indoor fan motor heat is deducted. 2. Capacities are based on the following conditions. Outdoor air : 85%RH. However, the condition on nominal capacity is 7 CDB/6 CWB(44.6 FDB/42.8 FWB) Corresponding refrigerant piping length : Direct piping - 25ft Distributor piping -16.4ft(Main) + 25ft(Branch) Level difference : 0 ft 3. TC=Total heating capacity(unit:1,000 Btu/h) 4. PI=Power Input(Comp.+indoor fan motor+outdoor fan motor) (kw) 5. This table is the capacity of circuit 1. Circut 2 is same. Correction Factor for Heating Capacity due to Frost on Heat Exchanger and Defrosting Operation. The heating capacity in the "Heating Capacity" Table above indicates the actual heating capacity excluding the effect of frost on the heat exchanger and the defrosting operation. Therefore, use the following factor to calculate the average heating capacity including capacity reduction by frost on the exchanger and defrosting operation. Correction Factor Outdoor Air Temperature ( FWB, RH=85%) Correction Factor MPS(Multi Power System) Variable Multi

122 8. Capacity Coefficient Factor 8.1 Rate of Change in Capacity by the Main Piping(Distributor) Length and the Direct Piping Length L4UC608FA0 Rate of Change in Cooling Capacity(%) 100.0% 95.0% 90.0% 85.0% 80.0% 75.0% 70.0% Rate of Cooling Change in Capacity by Main Piping Length & Direct Piping Length Main Piping Piping Length(m) 36k L5UC728FA0 Rate of Change in Cooling Capacity(%) 100.0% 95.0% 90.0% 85.0% 80.0% 75.0% 70.0% Rate of Cooling Change in Capacity by Main Piping Length & Direct Piping Length Main Piping Piping Length(m) 48k 2004 Product Data 121

123 8. Capacity Coefficient Factor L8UC1008FA0/L8UH1008FA0 Rate of Change in Cooling Capacity Main Piping Length(m) Rate of Change in Cooling Capacity % 98.8% 97.3% 95.8% 94.3% 92.8% 91.3% 89.8% 88.3% 86.8% Rate of Change in Heating Capacity Main Piping Length(m) Rate of Change in Cooling Capacity % 99.6% 99.2% 98.7% 98.3% 97.8% 97.4% 96.9% 96.5% 96.0% Rate of Change in Cooling Capacity(%) 100.0% 95.0% 90.0% 85.0% 80.0% 75.0% 70.0% Rate of Change in Capacity by Main Piping Length & Direct Piping Length Piping Length(m) : Rate of Change in Cooling Capacity : Rate of Change in Heating Capacity 122 MPS(Multi Power System) Variable Multi

124 8. Capacity Coefficient Factor 8.2 Rate of Change in Capacity by the Branch(Distributor) Piping Length 12k Btu/h(3.5 kw) models Piping Length (m) Rate of Change in Capacity Cooling Heating % 100.0% % 98.3% % 96.5% 24k Btu/h(7.0 kw) models Piping Length (m) Rate of Change in Capacity Cooling Heating % 100.0% % 99.2% % 98.4% 18k Btu/h(5.3 kw) models Piping Length (m) Rate of Change in Capacity Cooling Heating % 100.0% % 99.5% % 99.0% 30k Btu/h(8.8 kw) models Piping Length (m) Rate of Change in Capacity Cooling Heating % 100.0% % 99.1% % 98.2% 36k Btu/h(10.6 kw) models Piping Length (m) Rate of Change in Capacity Cooling Heating % 100.0% % 98.8% % 97.6% Rate of Change in Cooling Capacity(%) 12k Btu/h(3.5 kw) Models Rate of Change by Branch Piping Length 100.0% 99.0% 98.0% 97.0% 96.0% 95.0% 94.0% Branch Piping Length(m) : Cooling : Heating 2004 Product Data 123

125 8. Capacity Coefficient Factor Rate of Change in Cooling Capacity(%) 18k Btu/h(5.3 kw) Models Rate of Change by Branch Piping Length 100.0% 99.5% 99.0% 98.5% 98.0% 97.5% 97.0% 96.5% 96.0% 95.5% 95.0% Branch Piping Length(m) : Cooling : Heating Rate of Change in Capacity(%) 24k Btu/h(7.0 kw) Models Rate of Change by Branch Piping Length 100.0% 99.5% 99.0% 98.5% 98.0% 97.5% 97.0% 96.5% 96.0% 95.5% 95.0% Branch Piping Length(m) : Cooling : Heating 30k Btu/h(8.8 kw) Models Rate of Change by Branch Piping Length Rate of Change in Capacity(%) 100.0% 99.5% 99.0% 98.5% 98.0% 97.5% 97.0% 96.5% 96.0% 95.5% 95.0% Branch Piping Length(m) : Cooling : Heating 124 MPS(Multi Power System) Variable Multi

126 8. Capacity Coefficient Factor 36k Btu/h(10.6 kw) Models Rate of Change by Branch Piping Length Rate of Change in Capacity(%) 100.0% 99.5% 99.0% 98.5% 98.0% 97.5% 97.0% 96.5% 96.0% 95.5% 95.0% Branch Piping Length(m) : Cooling : Heating Method of calculating cooling / heating capacity : Total capacity from capacity tables x (Rate of Change in capacity by main piping length x Rate of Change in capacity by branch piping length) 2004 Product Data 125

127 9. Operation Limits Item Range Inlet air temperature (Cooling) Outdoor air temperature C D.B.( F) 54(129.2) 21(69.8) Standard operation 14(57.2) 24(75.2) Indoor air temperature C W.B.( F) Inlet air temperature (Heating) Outdoor air temperature C W.B.( F) 15.5(59.9) 0(32) Standard operation 14(57.2) 28(82.4) Indoor air temperature C D.B.( F) Power source voltage Voltage at starting Rating ±10% Min. 85% of rating 126 MPS(Multi Power System) Variable Multi

128 10. Sound Levels Overall D 1m Center of Outdoor Unit Notes: - Sound measured at 1m away from the center of the unit. - Data is valid at free field condition - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20µPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard (KS conditions) 1m Model L4UC608FA0 L5UC728FA0 L8UC1008FA0 L8UH1008FA0 50Hz, V Sound Levels(dBA) Sound Pressure Level L4UC608FA0 L5UC728FA0 L8UC1008FA0 L8UH1008FA Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Sound Pressure Level (db re 20µPa ) NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) NC Octave Band Center Frequency (Hz) 2004 Product Data 127

129 11. Installation 11.1 Select the best location If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted. Do not place animals and plants in the path of the warm air. Take the air conditioner weight into account and select a place where noise and vibration are minimum. Select a place so that the warm air and noise from the air conditioner do not disturb neighbors. Rooftop Installations : If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting. Model : L4UC608FA0 Ensure that the space around the back is more than 90cm and sides is more than 90cm. The front of the unit should have more than 90cm of space. Fence or obstacles More than 120cm More than 90cm Fence or obstacles More than 90cm More than 90cm More than 90cm Model : L5UC728FA0 (1) Individual installation Basic Space required A space of at least 250 mm is nessary at the back for inlet air. Tacking servicing, a space of about 750 mm should be provided at the front. C Rear B Front service space A D E A : 750 mm or more B : 250 mm or more C : Top discharge(open in principle) D : Front inlet(open in principle) E : Rear inlet(open in principle) <Side View> <Top View> 128 MPS(Multi Power System) Variable Multi

130 11. Installation When inlet air enters from right and left sides of unit A : 750 mm or more B : 250 mm or more C : 150 mm or more A B Rear B C C Front A <Top View> <Side View> When unit is surrounded by walls A : 750 mm or more B : 250 mm or more B B B A When there is an obstructure above the unit A : 45 or more B : 200 mm or more C : 250 mm or more D : 1000 mm or more E : Air outlet guide (procured at the site) F : 250 mm or more A B D C E F 2004 Product Data 129

131 11. Installation (2) Collective installation and continuous installation Space required for collective installation and continuous installation : When installing several units, leave the space between each block as show below considering passage for air and people. A : Open state B : 750 mm or more C : 250 mm or more D : 250 mm or more Rear Front Rear Front Model : L8UC1008FA0/L8UH1008FA0 (1) Individual installation Basic Space required A space of at least 250 mm is nessary at the back for inlet air. Tacking servicing, a space of about 750 mm should be provided at the front. C Rear B Front service space A D E A : 750 mm or more B : 250 mm or more C : Top discharge(open in principle) D : Front inlet(open in principle) E : Rear inlet(open in principle) <Side View> <Top View> 130 MPS(Multi Power System) Variable Multi

132 11. Installation When inlet air enters from right and left sides of unit A : 750 mm or more B : 250 mm or more C : 150 mm or more A B Rear B C C Front A <Top View> <Side View> When unit is surrounded by walls A : 750 mm or more B : 250 mm or more B B B A When there is an obstructure above the unit A : 45 or more B : 200 mm or more C : 250 mm or more D : 1000 mm or more E : Air outlet guide (procured at the site) F : 250 mm or more A D B C E F 2004 Product Data 131

133 11. Installation (2) Collective installation and continuous installation Space required for collective installation and continuous installation : When installing several units, leave the space between each block as show below considering passage for air and people. A : Open state B : 750 mm or more C : 250 mm or more D : 250 mm or more Front Rear Rear Front 132 MPS(Multi Power System) Variable Multi

134 11. Installation 11.2 Settlement of outdoor unit Anchor the outdoor unit with a bolt and nut(ø10mm) tightly and horizontally on a concrete or rigid mount. When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. In the case when the vibration of the unit is conveyed to the hose, secure the unit with an anti-vibration rubber. L5UC728FA0 Individual installation Installation foot 700± ±2 Example of collective installation 500± ± ±2 L8UC1008FA0/L8UH1008FA0 Individual installation Installation foot 700± ±2 Example of collective installation 900± ± ± Product Data 133

135 11. Installation 11.3 Lifting Method When carrying the unit suspended, pass the ropes under the unit and use the two suspension points each at the front and rear. Always lift the unit with ropes attached at four points so that impact is not applied to the unit. Attach the ropes to the unit at an angle of 40 or less. Use two ropes at least 7 m long. A 40 or less B Rope suspension part A 40 or less B Rope suspension part Caution: Be very careful to carry product. Do not have only one person carry product if it is more than 20 kg. PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous. Do not touch heat exchanger fins with your bare hands. Otherwise you may get a cut in your hands. Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death. When carrying in outdoor unit, be sure to support it at four points. Carrying in and lifting with 3-point support may make outdoor unit unstable, resulting in a fall of it. 134 MPS(Multi Power System) Variable Multi

136 12. Accessories Standard accessories Installation manual Optional accessories No. Name Model No. PMBD5420L(For 2 Indoor Units) 1 BD Unit PMBD5430L(For 3 Indoor Units) PMBD5440L(For 4 Indoor Units) 2004 Product Data 135

137 Memo 136 MPS(Multi Power System) Variable Multi

138 Part 4 Control 1. Basic Control Devices and Function Wired Remote Control Wireless Remote Control Central Control Simple Central Control(PQCSA101S0) Deluxe Central Control(PQCSW501A0, PQCSW502A0) PC Central Control(PQCSS501A0, PQCSS502A0)) Product Data 137

139 1. Basic Control Devices and Function 1.1 Wired Remote Control Appearance and Functions Appearance Functions (Button Descriptions) Ceiling Mounted Cassette Type: No. Name Function 1 Operation display Displays the operation conditions AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer Operation unit Program set On Off Set no. Time Timer Program Hour Cancel Week Min Holiday Set/Clr Plasma RESET On/Off Operation starts when this button is pressed, and stops when the button is pressed again. 3 Set Temperature Used to set the temperature when the desired temperature is obtained. 4 FAN Operation Used to circulate room air without cooling or heating. 5 Fan Speed Used to set the desired fan speed 6 Operation Mode Selection Used to select the operation mode. 7 Auto Swing Used to swing up and down. 8 Room Temperature Checking Used to check the room temperature. 9 Timer Cancel Used to cancel the timer. 10 Timer Set Used to set the timer when the desired time is obtained. 11 Week Used to set a day of the week 12 Program Used to set the weekly timer. 13 Holiday Used to set a holiday of the week. 14 Time Set Used to set the time of the day and change the time in weekly timer Function. 15 Set and Clear Used to set and clear the weekly timer. 16 Jet Cool Used to select jet cool mode. 17 Reset Used to set the current time and clear the setting time. Ceiling Concealed Duct Type: No. Name Function 1 Operation display Displays the operation conditions AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer Operation unit Program set On Off Set no. Time Timer Cancel Program Week Holiday SET/CLR Hour Min RESET On/Off 3 Set Temperature Operation starts when this button is pressed, and stops when the button is pressed again. Used to set the temperature when the desired temperature is obtained. 4 FAN Operation Used to circulate room air without cooling or heating. 5 Fan Speed Used to set the desired fan speed Operation Mode Selection Timer Set Timer Cancel Week Program Holiday Time Set Set and Clear Room Temperature Checking Reset 16 Signal Receptor Used to select the operation mode. Used to set the timer when the desired time is obtained. Used to cancel the timer. Used to set a day of the week Used to set the weekly timer. Used to set a holiday of the week. Used to set the time of the day and change the time in weekly timer Function. Used to set and clear the weekly timer. Used to check the room temperature. Used to set the current time and clear the setting time. Used to take the signal from wireless remote control 138 MPS(Multi Power System) Variable Multi

140 1. Basic Control Devices and Function 1.2 Wireless Remote Control Appearance and Functions Appearance Wall Mounted Type Art Cool Type Art Cool Mirror Type Functions (Button Descriptions) No. Name Function 1 START/STOP Operation starts when this button is pressed and stops when the button is pressed again. Signal transmitter 2 3 OPERATION MODE SELECTION ROOM TEMPERATURE SETTING Used to select the operation mode. Used to select the room temperature. 4 FAN SPEED SELECTOR Used to select fan speed in four steps (low, medium, high, or CHAOS.) ON OFF CANCEL SET AUTO CLEAN JET COOL 6 CHAOS SWING 7 ON/OFF TIMER Used to start or stop the speed cooling/heating. (Speedcooling/heating operates super high fan speed in cooling mode.) Used to stop or start louver movement and set the desired up/down airflow direction. Used to set the time of starting and stopping operation. 8 TIME SETTING Used to adjust the time. 9 TIMER SET/CANCEL Used to set the timer when the desired time is obtained and to cancel the Timer operation. 10 SLEEP MODE AUTO Used to set Sleep Mode Auto operation AIR CIRCULATION Used to circulate the room air without cooling or heating (turns indoor fan on/off). Flip-up door (opened) 12 ROOM TEMPERATURE CHECKING Used to check the room temperature. 13 PLASMA(OPTIONAL) Used to start or stop the plasma-purification function RESET BUTTON 2nd F Button AUTO CLEAN Used prior to resetting time or after replacing batteries. Used prior to using modes printed in blue at the bottom of buttons. Used to set Auto Clean mode Product Data 139

141 2. Central Control 2.1 Simple Central Control(PQCSA101S0) Features Easy operation button. Independent operation for 16 indoor units each. Simultaneous turn ON/OFF for all of indoor units connected. Easy change operation mode to cooling or heating Set and clear lock-mode for each indoor unit Simultaneously set and clear lock-mode for all of indoor units connected. Display function for all of indoor units connected Term of Each part and Function On/Off display LED (TOTAL 16EA) On pressing individual on/off button, display the present operation state. -Operation : green. -Stop : off -Error mode : blinking Individual On/Off button Control ON/OFF of a unit. Power display LED Indicate the state of DC Power supply in central control unit. - On : red(heating), green(cooling) - Off : no signal - Error mode : blinking with red color TOTAL Off button Stop all linked units sequentially. TOTAL On button Operate all linked units sequentially. 140 MPS(Multi Power System) Variable Multi

142 2. Central Control Electrical wiring PICTORIAL VIEW OF THE CONNECTION Outdoor unit MAIN PCB PI485 : PMNFP14A0 L PI485 MAIN PCB Control Box CN_CENTRAL MAIN PCB CN_CENTRAL N L PI G A B CN OUT VCC GND C D CENTRAL CONTROL UNIT Special purchase: Central control, PI485(PMNFP14A0) ONE SIMPLE CENTRAL CONTROL CONNECTION OUTDOOR MAIN PCB INDOOR UNIT 1 INDOOR UNIT 2 INDOOR UNIT 3 INDOOR UNIT 4 INDOOR UNIT 5 INDOOR UNIT SET The Address(Group No. & Indoor No.) * Refer to The Following sheet (1.3.5 Indoor unit Address setting method) Vcc GND C D BUS B BUS A GND +10V INDOOR UNIT 6 IC1P + S1 S5 CN-POWER LED2 + S2 S6 L LED3 CN-POWER GND LED4 + + CN-COM A S4 S3 CN-COM B Outdoor unit D C GND VCC + LED5 + LED9 + S9 + LED10 + S10 S14 LED7 + LED11 S11 LED8 LED12 + S15 + S12 S16 TX1 Group Number 0 LED13 + LED14 LED15 PWB:6870A10001A ASM:6711A20005E S15 LED16 S18 Master Mode LED17 ON KSDO4H L S19 All the connections are to be done as shown above. A and B are the communication lines for the indoor and C and D are the communication lines for the Central Control. Use two shield lines for C/D connecting line.(earth the shield line) VCC GND C D CENTRAL CONTROL UNIT 2004 Product Data 141

143 IC1P IC1P + LED5 + LED9 + LED13 + LED17 + LED5 + LED9 + LED13 + LED17 S1 S5 S9 ON KSDO4H L S1 S5 S9 S19 ON KSDO4H L S19 CN-POWER LED2 + + LED10 + LED14 CN-POWER LED2 + + LED10 + LED14 S2 S6 S10 S14 S2 S6 S10 S14 L LED3 LED7 LED11 LED15 PWB:6870A10001A ASM:6711A20005E S15 CN-POWER GND LED S11 LED8 LED12 + S15 + L LED3 LED11 LED16 S18 CN-POWER GND LED4 + + LED7 + S11 LED15 PWB:6870A10001A ASM:6711A20005E S15 LED8 LED12 + S15 + LED16 S18 CN-COM A S4 S3 S12 S16 CN-COM A S4 S3 S12 S16 TX1 TX1 CN-COM B CN-COM B 2. Central Control 2 OR MORE SIMPLE CENTRAL CONTROL CONNECTION INDOOR UNIT 1 INDOOR UNIT 2 OUTDOOR MAIN PCB BUS B BUS A GND +10V Outdoor unit 1 INDOOR UNIT 3 INDOOR UNIT 4 INDOOR UNIT 5 INDOOR UNIT 6 D C GND VCC INDOOR UNIT 1 INDOOR UNIT 2 Vcc GND C D Master Mode Group Number 0 <Group Number 0> Master DIP SWITCH 1. Adhere the PI485 Module(For connecting central control) to the Control Box. 2. Connect the PI485 Module to central control. 3. In the case of connecting two more than central control, set the Master/Slave mode and then connect each communication lines(c,d) <Refer to above fig>. *Special purcharse: Central control(pqcsa101s0), PI485 Module(PMNFP14A0) * It can be added to 15 Central controls for the slave control. OUTDOOR MAIN PCB BUS B BUS A GND INDOOR UNIT 3 INDOOR UNIT 4 INDOOR UNIT 5 INDOOR UNIT 6 Vcc GND C D <Group Number 1> Slave DIP SWITCH Note 001 Group No. +10V Indoor No. Outdoor unit 2 D C GND VCC Master Mode Group Number PI485 setting method(lg Air-conditioner Network unit, PMNFP14A0) Selection of product unit type Selection of network type ON KS DO 4H L Settings method of MPS Variable Multi Type ON KS DO 4H L ON KS DO 4H L ON + All OFF : Connection of "MPS Variable Multi Connection + General Central Controller" Case. 1,4 ON + All OFF : Connection of "MPS Variable Multi Connection + Central Controller applied LGAP " Case. * LGAP : LG Air conditioners Protocol Function of LG Network - It is possible to connect the network of LG air conditioners and to connect various contents of the network system, which is simple, deluxe and PC central control. - Please refer to "LG Control System Manual" about the detail functions and the products possible to network. - As the Interface for networking, PMNFP14A0 is applied. 142 MPS(Multi Power System) Variable Multi

144 2. Central Control Indoor Unit Address setting Method Using Wired Remote Control AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp HI AUTO Heater Preheat MED JET Defrost Humidify LO Filter Out door Time ZONE Timer Operation unit Program set On Off Set no. Time Timer Program Hour Cancel Week Min Holiday Set/Clr Plasma RESET Heat Pump Model Using Wireless Remote Control Press 13(program) and 16(set and clear) key more than 3 second then "Address Setting Mode" starts. 2. Set the address of indoor unit by using "Temperature setting" key. Range of address : 00 ~ FF Ex) 3 A Group Room(Indoor Unit) No. No. 3. After setting address, press 13(program) and 16(set and clear) key more than 3 second then "Address Setting Mode" is finished. 1. Address setting Method 5 6 Signal transmitter 1 3 1) Press 5(Jet Cool) & 13(Reset) key at the same time more than 3 seconds then "Address Setting Mode" starts. 2) Set the address of indoor unit by using "Temperature setting" key. Range of address : 00 ~ FF Ex) 3 A ON OFF CANCEL AUTO CLEAN 2. Address Monitoring SET Flip-up door (opened) Group Room(Indoor Unit) No. No. 3) After address setting, pressing 1(On/Off) key, address setting is finished. The address that is set is displayed on a display window of indoor unit. * notice : The mothod of display and time is different according to indoor unit type. 4) If the remote control is reset, normal mode starts. 1) Press 6(Chaos Swing) & 13(Reset) key at the same time then "Address Monitoring Mode" starts. 2) At the address monitoring mode, pressing 1(On/Off) key, The address that is set is displayed on a display window of indoor unit. * notice : The mothod of display and time is different according to indoor unit type. 3) If the remote control is reset, normal mode starts. * Notice : Confirm that wired and wireless remote control are able to select the address or not Product Data 143

145 2. Central Control Test run method 1. Set the wiring of system and indoor unit. 2. Apply power to the setting. 3. Do auto addressing to the outdoor unit. 4. After addressing, initialize the central controller(manual initialize: Total on + total off + 16 key). Cooling: Setting basically(total On + Total Off + 4 key) Heating: Total On + Total Off + 8 key Red power lamp 'On' 6. Check up On/Off with a related indoor key pressing Installation CAUTIONS Do not install in this area Don t install near elevator, computer, automatic door. (High noise area). Keep in mind Don t operate with wet hands. Don t install near high moisture & high oscillation area. Don t pull the connected wire. Don t install near direct sunlight or heat source. 144 MPS(Multi Power System) Variable Multi

146 2. Central Control INSTALLATION ORDER 1. Remove upper & lower case. 2. Fixate screw in the holes of the case bottom. 3. For Dip switch, and Rotary switch setting, refer to the page How to Install. 4. For wiring connection, refer page Installation Procedure 5. Adjust the upper case in accordance with back case while assembling as shown in the figure. 6. Check the operation by supplying the power. LINK OF CONNECTING WIRE 1. First, separate the front case from rear case of controller, connect terminal C, D,Vcc, GND on PCB referring to the following table. Maximum length of connecting wire Vcc GND C D Between controller and outdoor unit : 220m(25Ω ) Between controllers : 220m(25Ω ) Out door unit Terminal Block Wire Color Central Control Terminal GND BLUE GND Vcc Red Vcc C Brown C D Yellow D 2. After attaching the supplied wire to terminal, link the connecting wire. If necessary, Cut the indicated part of front case to draw the lead wire Product Data 145

147 2. Central Control. ROTARY SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL) The setting of Group Number in the Central Control is done by the rotary switch as shown in the figure below. It is possible to set 0~15 Group(Total 16 Groups). All the numbers on the rotary switch represent the different Group Numbers. By changing the knob we can set rotary switch to the group number we want to control. The above fig. Shows the control of group number 0. Similarly we can control all the 16 Groups.. DIP SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL) CAUTION Dip switch is now used only for the setting of master or slave mode.( In the case of two more than central controls.) Set one to Master, the others to slave. Rotary Switch Master Mode Dip Switch ON OFF Slave Mode. ACCEASSORY PARTS Central control and sub PI485(with wire assembly) should be purchased as optional. Central Control (PQCSA101S0) PI485(PQNFP14A0) Wire Assembly 1 Screw(4EA) Wire Assembly MPS(Multi Power System) Variable Multi

148 2. Central Control 2.2. Deluxe Central Control(PQCSW501A0, PQCSW502A0) Introduction SUMMARY Deluxe Central control is a product available for individual and integrated monitoring and control of maximum 256 of MPS Variable Multi air conditioner systems. Specially, operation status of the individual air conditioner can be particularly checked. Individual or simultaneous operation of the air conditioner, operation mode, wind quantity, user locking and temperature setup are also available. Specially for this system, installation is simple and user's environment is excellent. Central control is available by a simple manipulation. In addition, this system have the self-battery built-in and can stably operate in spite of outside disturbance such as temporary power failure. This system has no need of additional peripheral equipment like UPS (Undisturbed Power System) and AVR to be purchased for stability when composing the existing PC central control system, and has so attractive advantage in installation costs. Using the Deluxe Central control enables the management room to setup lock of each air conditioner and prevent indoor control of the individual air conditioner and restrain the necessary use. In case of releasing the lock, you may control the system by using the wire/wireless remote control at the place where the individual air conditioner is installed. Setup of a weekly schedule is available and detailed schedule of the individual air conditioner can be easily setup through the GUI. Details of schedule setup can be immediately checked with a graph. This system is a product to meet energy saving and convenience at the same time at a place like a school by using this schedule function. Depending on installation environment, location and conditions of use, you can setup groups. With this setup, more efficient operation at the center is available. Setup without requiring other equipment is available by using the GUI and change by the consumer is also available after installation. You can reduce development time to configure special system upon the request by the consumer and conveniently this system by using the touch panel. Where needs from a new customer occur or where purchase of additional air conditioner is done, the Deluxe Central control can be smoothly installed. Deluxe Central control CNU PI485 PI Product Data 147

149 2. Central Control Major Characteristics Figure 2) Deluxe Central control 1. Individual/Integrated Operation/Monitoring You can identify operation status of the air conditioner, operation mode, wind quantity, wind direction, locking, temperature setting and error, etc by selecting the installed air conditioner through individual selection, group selection or all selection. Individual setup and operation of the detailed functions are available. Therefore, managing with Deluxe Central control installed at the control room at a building where a number of air conditioners are installed, is a convenient way. 2. Group Management Group management for the installed air conditioners is available. Group can be seperated by their nature, location and size of each air conditioner which enables convenient use. In addition, allotment of respective name to the setup group allows further intuitive management. 3. Self-diagnosis Function The air conditioner installed can self-diagnosed its error status and then transmits the result to the central control. Therefore, a rapid countermeasure against failure of the air conditioner allows easy management and increases the usage life of air conditioner. 4. Semi-permanent Life / Convenient Maintenance Since the Deluxe Central control is designed for the semi-permanent use, this system can be used semipermanently after installation, different from the existing PC or a large central control system requiring a continuous management due to the life of peripheral and other PC. 5. Management Costs Down In absence of the Central Control System, the manager controls a number of air conditioners. In addition, even if management was done at the center, there is only function of on/off management at best and thus 2 or 3 building managers were actually required. However, manipulation of all functions can be now done at a control room for the Deluxe Central control and so a manager can easily control all air conditioners. Automatic operation is also allowed without a manager, by using schedule function. 148 MPS(Multi Power System) Variable Multi

150 2. Central Control 6. Convenient GUI / Touch Screen Not requires special education for using the Deluxe Central control, conveniently used only by pressing the buttons on the screen, and its function can be understood with intuitive pictogram. Especially schedule setting is done by simply by dragging, different from the existing system requiring to press the button by more than average 30 times to enter a schedule. 7. Schedule Automatic Operation Management / Energy Saving For the Schedule Automatic Operation, weekly setting is available. Enlisting of the schedule exception processing schedule (national holiday) is done for a year prevents the air conditioner from an unnecessary operation of air conditioner, allowing the system to be controlled at the center so that it can be only used for a necessary case and enabling to obtain excellent energy saving effect. Fixed schedule places like elementary school, middle school, high school and college or university will get its excellent working effect. 8. Power Failure Backup Function / Powerful Stability For the existing Central Control System, additional purchase of expensive UPS equipment in provision for a temporary power failure must be done in the past but for the Deluxe Central control, since the self-power failure compensation battery is built-in, power is automatically converted by maximum 2 hours. Therefore, there is almost no malfunction due to a temporary power failure because stable operation is available. 9. Mobility A wireless radio system may be installed at the Deluxe Central control, it will control the Airconditioners directly while going around the building with the wireless radio system and its self-battery function (100 m where there is no obstacle). 10. Convenient Installation This system can be freely fixed to the wall surface because of its small size, light weight and thin thickness. It can also stood up on the desk by using, its dedicated cradle. It is not subjected to spatial restriction in installation space and location since this system communicates on the basis of the I-GW and the Ethernet. 11. Stable Date Storage/Backup Setup information is saved as it is, even if no power is supplied then also all data is saved in the built-in flash memory. 12. Scalability Scalability of the system is easy in case of additionally purchasing equipment since scalable slot such as USB, Serial (RS-232c), PCMCIA, CF Type is prepared. This system is designed considering sufficient scalability in provision for special request by the customer. 13. Upgrade Additional installation of a new program is available via the CF memory card and the existing program can be upgraded to a new program. Using such upgrade function always enables to construct a modern type of Central Control System Product Data 149

151 2. Central Control Figure 3) Deluxe Central control Table 1) Comparison Between Central control Characteristics Dedicate PC Configuration Position of program Max. installation set numbers Remote control Control & monitoring Schedule management System setup PC Central control Required User S/W, Engine S/W Installation 256 sets1) - Available Available Available Deluxe Central control Non-required Main Body of Web Pad Deluxe Central control Built-in 256 sets - Available Available Available System monitoring(overview) User s lock Upgrade Touch screen Built-in Flash DB (backup) Wireless LAN (movable) Non-interruption device Requirements Life Available Available Available Separately add JVM (provided by MS) 2) Peripheral devices & PC life Available Available Available Built-in Built-in Available (option) Built-in - Semi-permanent 1) For the PC central control, installation set numbers may respond up to 1024 sets upon user s request. 2) JVM (Java Virtual Machine) is basically installed at the Windows but some versions of Window XP may be manually installed. 150 MPS(Multi Power System) Variable Multi

152 2. Central Control Major Function of Deluxe Central Control [ System Control ] To check general monitor function of the air con central control system such as selection of group and air conditioner, air conditioner control monitor function etc. PQCSW501A0, PQCSW502A0 [ System Monitor ] To check the ctual time status of all air conditioners. PQCSW501A0, PQCSW502A0 [ System Set-up ] To manage the air conditioner through grouping and record setup of group and installation position, etc. PQCSW501A0, PQCSW502A0 [ Time Schedule ] Setup of a weekly schedule for all, group and individual air conditioner enabled operation of the system. Processing through enlist of extra schedule for a year is available. PQCSW502A Product Data 151

153 2. Central Control System Configuration Scenario 1 : In case of not using Internet access function Control System B part Interface A part Product Delux Central Control CNU PI485 PI485 Cross UTP Cable (Cross LAN Cable) RS-485 Cable PI485 PI485 Main Specifications * CNU: Central control Network interface Unit PI485: Product Interface unit for IEEE485 transmission. 1. Control System(PQCSW501A0, PQCSW502A0) - Centralized control of maximum 256 indoor units - Simple Touch PAD method - GUI setting considering convenience of use - Power failure compensation with independent Battery Built-in (Max. 2 hours) 2. CNU (PQNFG00A0) - Combination of maximum 8 outdoor units to Ethernet Converter Built-in 3. PI485(PMNFP14A0) - 1 pcs per outdoor units (Control of 8 outdoor units per bridge) Note: - GUI(Graphic User Interface) may be changed without any notice, for improvement or options. - Deluxe central control, CNU and sub PI485(with wire assembly) should be purchased as optional. 152 MPS(Multi Power System) Variable Multi

154 2. Central Control 2.3 PC Central Control (PQCSS501A0, PQCSS502A0) MajorFunction of PC Central Control [ System Control ] To check general monitor function of the air con central control system such as selection of group and air conditioner, air conditioner control monitor function etc. PQCSS501A0, PQCSS502A0 [ System Monitor ] To check the current actual time status of the whole of air conditioner. PQCSS501A0, PQCSS502A0 [ System Set-up ] To manage the air conditioner through grouping and record setup of group and installation position, etc. PQCSS501A0, PQCSS502A0 [ Time Schedule ] Setup of a weekly schedule for all, group and individual air conditioner enables operation of the system. Processing through enlist of extra schedule for a year is available. PQCSS502A Product Data 153

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS MULTI TYPE ROOM IR CONDITIONERS INSTLLTION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed

More information

Universal System Air Conditioner

Universal System Air Conditioner website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG LG Universal System Air Conditioner SERVICE MANUAL CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS

More information

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) (60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) (60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) CONTENTS Part 1 General information Part 2 Product data Part 3 Design and installation Part 4 Special parts 2 Introduction

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GQAA2 ARNU09GQAA2 ARNU12GQAA2 ARNU15GQAA2 CAUTIN Before Servicing the unit, read the safety precautions

More information

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View) Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL: MD12Y3JM 960-920-06

More information

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type KSWT SERIES INSTALLATION INSTRUCTION Wall-mounted Split Type INSTALLATION 1. Characteristics of refrigerant 1.1 Temperature-pressure relationships in saturated condition Pressure (kg/cm2 G) 35 30 25 20

More information

Functions. Indoor Unit. Operation ON/OFF by Remote controller. Sensing the Room Temperature Room temperature sensor. (THERMISTOR)

Functions. Indoor Unit. Operation ON/OFF by Remote controller. Sensing the Room Temperature Room temperature sensor. (THERMISTOR) Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature sensor. (THERMISTOR) Room temperature control Maintains the room temperature in accordance with

More information

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View) Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL: MD18Y3JM 960-920-07

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU05GSB*4 ARNU07GSB*4 ARNU09GSB*4 ARNU12GSB*4 ARNU15GSB*4 ARNU18GSC*4 ARNU24GSC*4 CAUTIN Before Servicing

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU09GTL*4 ARNU12GTL*4 ARNU18GTL*4 ARNU24GTL*4 CAUTIN Before Servicing the unit, read the safety precautions

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU05GL1G4 ARNU15GL2G4 ARNU07GL1G4 ARNU18GL2G4 ARNU09GL1G4 ARNU21GL3G4 ARNU12GL2G4 ARNU24GL3G4 CAUTIN

More information

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Wall Mounted Air Conditioner SVC MANUAL(Exploded View) MODEL : AMNW07GDBL1 [LMN077HVT] AMNW09GDBL1 [LMN097HVT] AMNW12GDBL1 [LMN127HVT] AMNW15GDBL1 [LMN157HVT]

More information

Room Air Conditioner SERVICE MANUAL

Room Air Conditioner SERVICE MANUAL WEBSITE E-MAIL http://biz.lgservice.com http://www.lgeservice.com/techsup.html Room Air Conditioner SERVICE MANUAL CAUTION -BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. -ONLY

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU183TL*2 ARNU243TL*2 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU18GTL*2 ARNU24GTL*2 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GTU*4 ARNU09GTU*4 ARNU12GTU*4 ARNU18GTT*4 ARNU24GTT*4 CAUTIN Before Servicing the unit, read the

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

(Non-Inverter & Inverter) R410A

(Non-Inverter & Inverter) R410A LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU183NJA2 ARNU243NJA2 ARNU303NJA2 ARNU363NJA2 ARNU423NKA2 ARNU483NKA2 ARNU543NKA2 CAUTIN Before Servicing

More information

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU18GS5*2 ARNU24GS5*2 CAUTIN Before Servicing the unit,

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

Multi Type Room Air Conditioner

Multi Type Room Air Conditioner Multi Type Room Air Conditioner SERVICE MANUAL INDOOR UNIT: AMNN076L/M/NQA0 AMNN096L/M/NQA0 AMNN6L/M/NRA0 AMNN86L/M/NTA0 AMNN46L/M/NTA0 AMNN096APA0 AMNN6APA0 AMNN6TEA0 AMNN86TEA0 AMNN86VBA0 OUTDOOR UNIT:

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

SVC Manual(Exploded View)

SVC Manual(Exploded View) SVC Manual(Exploded View) Model : M18YJ M18CJ M24CJ Product Specifications System 18k 18k 24k System M18YJ M18CJ M24CJ FAC Model Name Outdoor Unit MR18Y3J MR18C3J MR24C3J Indoor Unit MW18Y3J MW18C3J MW24C3J

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

INSTALLER S GUIDE ART COOL SERIES FLOOR STANDING SERIES DUCT-FREE SPLIT AIR CONDITIONING SYSTEMS

INSTALLER S GUIDE ART COOL SERIES FLOOR STANDING SERIES DUCT-FREE SPLIT AIR CONDITIONING SYSTEMS DUT-FREE SPLIT AIR ONDITIONING SYSTEMS ART OOL SERIES FLOOR STANDING SERIES INSTALLER S GUIDE Art ool Display Rack Item # ASRK LG Electronics, HVA Division 1000 Sylvan Avenue Englewood liffs, NJ 07632

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) Internal Use Only http://biz.lgservice.com LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) MODEL : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L

More information

Energy Related Products SUPER DC INVERTER SERIES

Energy Related Products SUPER DC INVERTER SERIES Energy Related Products SUPER DC INVERTER SERIES Service Manual 2013 LFIS-B-1309 Contents i Contents Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 65 Part 4 Installation...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

2018 / 2019 RESIDENTIAL AIR CONDITIONERS

2018 / 2019 RESIDENTIAL AIR CONDITIONERS 2018 / 2019 RESIDENTIAL AIR CONDITIONERS UNIQUE FEATURES 2 Embedded Wi-Fi 10-Year Inverter Compressor Warranty 9 Smart Diagnosis Plasmaster IonizadorPLUS 3M Micro Dust Filter Low Heating Mode Lock Low

More information

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL Duct Type Series MH FECA INSTALLATION MANUAL Duct Type Series MH FECA ENGLISH FRANÇAIS ESPAÑOL Free Joint Multi Air Conditioner (Cooling and Heating) E S F DB98-960A() Safety Precautions The following safety precautions must be

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR C18 GE AIR C24 GE AIR C34 GE AIR C41 1 Introduction and Features Model Remarks

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1 Order No: MAC0512115C1 CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU Air Conditioner CONTENTS Page Page 1 Safety Precautions 3 2 Specification 5 2.1. CS-E18EKU CU-E18EKU 5 2.2. CS-E21EKU CU-E21EKU 7 3 Location

More information

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S Split Air Conditioner Model: WMI09MH16S WMI12MH16S WMI18MH16S Thank you for choosing our product. For proper operation, please read and keep this manual carefully. Content Operation Notices Precautions...1

More information

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

Wall Mounted Split Systems G-Series AP - MWM - G - 06A Wall Mounted Split Systems G-Series AP - MWM - G - 06A Air Purifying System Negative Ion Generator (Standard) The Ion Generator releases negative ion shower to create a refreshing and clean environment

More information

Choosing the installation site. Installation. 07 Choosing the installation site

Choosing the installation site. Installation. 07 Choosing the installation site Installation Installation warnings: 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state, and national electrical codes and by qualified,

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

2017 / 2018 RESIDENTIAL AIR CONDITIONERS

2017 / 2018 RESIDENTIAL AIR CONDITIONERS 2017 / 2018 RESIDENTIAL AIR CONDITIONERS SMART Embedded Wi-Fi Control your air conditioners via using the smart internet devices as Android or ios based smartphones. This advanced technology provides you

More information

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View) MDEL : ARNH10GK2A2 / ARNH04GK2A2 CAUTIN Before Servicing the unit, read the safety precautions in

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

LG Room Air Conditioner

LG Room Air Conditioner website http://www.lgservice.com LG Room Air Conditioner SERVICE MANUAL MODELS: AS-H0764DM0 AS-H0964DM0 AS-H1264DM0 AS-H1865DM0 AS-H2465DM0 LS-C1865DM0 LS-C2665DM0 LS-H1865DM0 LS-H2665DM0 AS-C0764DM0 AS-C0964DM0

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LSN090HYV / LSU090HYV LSN120HYV / LSU120HYV CAUTION Before Servicing the unit, read the safety precautions

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

DELUXE HIGH WALL MINI SPLIT

DELUXE HIGH WALL MINI SPLIT DELUXE HIGH WALL MINI SPLIT SERVICE MANUAL MODEL : HMC030KD1 HMH030KD1 CAUTION -BEFORE SERVICING THE UNIT, READ THE "SAFETY PRECAUTIONS" IN THIS MANUAL. -ONLY FOR AUTHORIZED SERVICE PERSONNEL. International

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can be made up

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 2010 Air Conditioning System 2010 Air Conditioning System Enjoy a clean

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com FREE JOINT MULTI Multi-Zone Mini Split Air Conditioner *Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰ quietside.com Ver 1-7.13 F DB, 43⁰F WB. FREE JOINT MULTI - Features and

More information

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW22AL 387030005 AW28AL 387030006 AW38AL 387030007 AW42AL 387030094 0.8180.467.0

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

INDOOR UNIT PRODUCT OVERVIEW

INDOOR UNIT PRODUCT OVERVIEW PI_MultiV_IDU_ProductOverview 6 INDOOR UNIT PRODUCT OVERVIEW Ducted 7,500 to 95,900 Btu/h Ceiling Cassettes 5,500 to 8,00 Btu/h Ceiling Suspended 9,00 and,00 Btu/h Wall-Mounted 5,500 to 5,500 Btu/h Floor

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

Installation manual for room air conditioner

Installation manual for room air conditioner Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O

More information

M-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

M-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP M-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca M-SERIES PRODUCT CATALOGUE The Attraction of Being Untraditional Mr. Slim M-Series is the ideal solution for homes and light

More information

Installation Instructions

Installation Instructions 40MBCQ Cassette Ductless System Sizes 09 to 8 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS INDOOR... 5 CLEARANCES INDOOR...

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. R COOL EER 0V ~ 50Hz 1Ph HEAT COP Heat Pump High Wall Split Systems 1K - 18K - 4K 0K - 6K Plasma Green Plasma Green Technology 1K-18K-4K Tropical Compressor

More information

FLEX MULTI SPLIT DUAL ZONE & TRI-ZONE INSTALLATION INSTRUCTIONS

FLEX MULTI SPLIT DUAL ZONE & TRI-ZONE INSTALLATION INSTRUCTIONS FLEX MULTI SPLIT DUAL ZONE & TRI-ZONE INSTALLATION INSTRUCTIONS IMPORTANT! Please read this instruction sheet completely before installing the product. This air conditioning system meets strict safety

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

FAN COIL USER MANUAL TC18C2DWB1 TC24C2DWB1 TC37C2DWB1 TC48C2DWB1 TC60C2DWB Innovair Corporation. All Rights Reserved.

FAN COIL USER MANUAL TC18C2DWB1 TC24C2DWB1 TC37C2DWB1 TC48C2DWB1 TC60C2DWB Innovair Corporation. All Rights Reserved. FAN COIL USER MANUAL TC18C2DWB1 TC24C2DWB1 TC37C2DWB1 TC48C2DWB1 TC60C2DWB1 Duct Type 1. Features...7 2. Dimensions...8 3. Service Space...9 4. Wiring Diagrams...10 5. Capacity Tables...11 6. Capacity

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Ductless Split Systems Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Technology IAQ Catechin Plus Air Purifying System 13 to 17 SEER

More information

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information