IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Size: px
Start display at page:

Download "IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS."

Transcription

1 INSTALLATION/OPERATING INSTRUCTIONS FOR C100 & C100T Thank you for purchasing a quality Extractor fan from Greenbrook. Please read these instructions fully prior to initial use. Every effort has been made to ensure that the guidance information on this sheet will enable the installation of the fan to be carried out safely and correctly. IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS. WHEN INSTALLING FANS, SWITCH OFF MAINS SUPPLY BEFORE MAKING ELECTRICAL CONNECTIONS. IMPORTANT 1. All fans may be fitted to a wall or ceiling. 2. These fans are double insulated and do not require an earth connection. 3. The fans electrical supply, must be connected via a double pole switched fuse connection unit, having a contact separation of at least 3mm in all poles fitted with a 3 amp fuse. This must be sited outside of a room containing a fixed bath or shower. 4. For best performance, fans should be mounted on a wall as high as possible. 5. Wall mounted fans are not intended for use with ducting beyond 2 metres in length. 6. Extraction fans should not be located in rooms containing open flued appliances. 7. Do not install 230V fans in a shower or bathroom application where the fan may be within reach of someone using a bath or shower, or subjected to water spray (zones 0,1 and 2).

2 INSTALLATION Select a suitable mounting position for the fan ensuring there are no hidden obstructions and work out the cable runs. Please Note: Using long lengths of ducting will reduce the efficiency of the fan, whenever possible keep the ducting straight and the distanced as short a possible. Warning: Ensure that the mains supply is isolated before making any electrical connections. Dia 1 - Wall Kit Installing The in an External Wall Dia 2 - Installation in an External Wall External Grille External Wall Cavity Possible Cable Position Fixed Grill or Cavity Shutter Flexible Ducting 100mm Inside Diameter Ducting Interior Wall 1. Cut a hole through the wall, sized to give a small clearance on 100mm inside diameter ducting. 2. Remove the front cover from the fan by removing the two screws behind the grille, then carefully twist the grille off. 3. Pierce the cable entry seal. 4. Hold the fan body assembly (terminal block to the top) centrally in the hole and mark two fixing positions and the cable entry. 5. Drill and plug the two fixing positions and chase a groove for the cable. Fix the cable in position,ensuring sufficient length is left for the connections. 6. Bridge the wall cavity using a length of rigid or flexible 100mm inside diameter ducting and make good the wall surfaces where necessary. 7. Fix the fan body assembly to the wall using pan head screws of a suitable length. 8. Make the correct electrical connections (see wiring diagrams) to the terminal block and clamp the cable securely to the fan body.

3 IMPORTANT Ensure that the fan blades rotates freely. Refit the front cover and tighten the locking screws. Fit a suitable external grille or gravity shutter models G425/G400, Shown in Dia 2. Dia 3 - Installation in a ceiling Installing The in a Ceiling Dia 4 - Venting through a roof 100mm Inside Diameter Ducting Roof cowl and weathering slate Joist Possible Cable Position Roof cowl and weathering slate Plastic pipe 100mm inside dia flexible ducting Fixed Grille Support 100mm inside dia flexible ducting sloping away from fan Trap with water run off for major condensation Trap for major condensation 1. If fitting the slimline fan in a ceiling first remove backdraft shutter. 2. Fit a firm support between the joists. 3. Cut a hole through the ceiling and support sized to give a small clearance on 100mm inside diameter ducting. 3. Remove the front cover from the fan by removing the two screws behind the grille, then carefully twist the grille off. 5. Pierce the cable entry knockout. 6. Hold the fan body assembly centrally in the hole and mark two fixing positions and the cable entry. 7. Drill pilot holes for the fixing positions and a clearance hole for the cable. 8. Fix the supply cable in position ensuring sufficient length is left for the electrical connections. 9. Fix the fan body assembly to the ceiling using pan head screws of a suitable length. 10.Install ducting from the fan spigot either through the roof using a weatherproof slate and roof cowl, or under the eaves using an external fixed grille model G Make the correct electrical connections (see wiring diagrams 6 & 7) to the terminal block and clamp the cable securely to the fan body.

4 WARNING If installing any ducting which will be positioned higher than the fan itself, a condensation trap must be used, this should be fitted as close to the fan as possible. ducting outlet must be positioned well away from any existing flue gas outlets such as central heating exhausts IMPORTANT Ensure that the fan blades rotate freely. Refit the front cover and tighten the locking screws. Installation for Timer Version Only 1. Install as for wall or ceiling above. 2. Connect the supply wires to the fan referring to (Dia.7). 3. To adjust the timer, turn timer control (Dia.5) anticlockwise to reduce time on, (2 mins approx), clockwise to increase time on (30 mins approx) 4. Re-fit the front grille onto the motor housing with two screws removed previously. Dia 5- Timer Control n t l NOTE: 1. The fan will automatically start up 20 seconds after it is switched on, and will continue to operate for the pre-set time after it is switched off. 2. The Max load of timer is 11 Watt.

5 WIRING DIAGRAMS Dia 6 - Standard Models Terminal L - Live Supply Terminal N - Neutral Supply Extractor Double Pole Switched Fused Connection Unit 3Amp Fuse Fitted Dia 7 - Overrun Timer Model Terminal L - Terminal T - Terminal N - Extractor Permanent Live Supply Switched Live Supply Neutral Supply Double Pole Switched Fused Connection Unit 3Amp Fuse Fitted Ceiling Junction Box Pullcord Switch Pullcord Switch MAINTENANCE Disconnect the electrical supply. 1. Remove the front grille and clean with a damp cloth and neutral detergent. The interior parts of the appliance can be cleaned with a damp cloth. 2. Take care not to wet the motor, the timer or other electrical components. 3. Thoroughly dry all parts of the appliance before reassembly. 4. Reconnect the appliance to the electrical supply. IMPORTANT NOTE All electrical work must conform to BS7671 the current IEE wiring regulations and part P of building regulations. You are advised to check with your local authority s Building Control Department, or an Authorised Competent Person, before starting. If in any doubt about electrical work, contact a qualified electrician. A direct replacement, without a wiring change, need not be notified to your Building Control Department.

6 TECHNICAL DATA Rated Voltage: 230V, AC 50Hz Load: 11W Maximum IP Rating: IPX4 Air movement: Up to 80 Cubic Metres/Hour (22.2 Litres/Sec) Insulated: Class II Double Is a Brand Name of GreenBrook Electrical PLC PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE GreenBrook Helpline : WEST ROAD. HARLOW ESSEX. CM20 2BG. UK s a l e g r e e n b r o o k. c o. u k Issue no:

Installation & Operating Instructions

Installation & Operating Instructions Installation & Operating Instructions For 4 / 100mm Centrifugal s Models: K612 & K612T Thank you for purchasing a quality Centrifugal from GreenBrook. Please read these instructions fully prior to initial

More information

Installation & Operating Instructions

Installation & Operating Instructions Installation & Operating Instructions For 12V Extractor s Models: (4 ) G510SELV, (6 ) G242SELV For 12V Controllers Models: 12VFC, 12VFCT & 12VFCHS Thank you for purchasing a quality 12V Extractor & Controller

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

irconcentre.co.uk airooncentre.co.uk

irconcentre.co.uk airooncentre.co.uk Installation and maintenance instructions DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet/Bathroom

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use Internal/External Wall/Window Fan Range GX6 Installation and maintenance instructions Retain for future use A GLASS WINDOW B C D ( 6 see F ) 13 E1 E2 E3 G1 G2 G3 G4 H I GB Xpelair GX6, GXC6, GXC6T, GX6HT

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 16 24-100B 44 16 25-100T 44 16 26-100HT 44 16 28-150B 44 16 29-150T 44 16 30-150HT 220-240V~50Hz

More information

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR Installation and operating instructions LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord Safety extra low voltage toilet/bathroom 100mm fan range Integral

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ

More information

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T EN Trimbox Mixed Flow Fans TP220T TP221T TP222T TP223T Product Manual ventilation systems Safety Information Important Information Important: read these instructions fully before the installation of this

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

Lo-Carbon T-series Window & Roof Models

Lo-Carbon T-series Window & Roof Models Lo-Carbon T-series Window & Roof Models Installation & User Instructions WIRED 456165A (9 WW) 456168A (9 RF) 456173A (12 WW) 456176A (12 RF) WIRELESS 456169A (9 WW) 456172A (9 RF) 456177A (12 WW) 456180A

More information

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or Domestic AC Fans 230V Installation and Operating Guide 230V AC Base Models: ico15 72683501 ico15c 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Window & Roof Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456165A (9" WW) 456168A (9" RF) 456173A (12" WW) 456176A (12" RF) WIRELESS 456169A (9" WW) 456172A (9"

More information

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan Simply Silent Contour 4 (100mm) Axial Extraction Fan Suitable for bathrooms, toilets, shower and utility rooms Controls humidity, odours and mould growth Sleek low-profile design, wall or ceiling mounting

More information

Turbo Inline Fan, White - Non Illuminated Art no.33500

Turbo Inline Fan, White - Non Illuminated Art no.33500 Quality Bathroom Products Turbo Inline Fan, White - Non Illuminated Art no.33500 Turbo Inline Fan, White - Cool White LED Art no.300 Turbo Inline Fan, White - Warm White LED Art no.34000 Turbo Inline Fan,

More information

EVG Extractors. Manual for Installation, Use and Maintenance

EVG Extractors. Manual for Installation, Use and Maintenance EVG Extractors Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W :

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

100cm Chimney Hood GB IE

100cm Chimney Hood GB IE 100cm Chimney Hood GB IE [01] x 1 [02] x 2 [03] x 2 [04] x 2 [05] x 3 [06] x 1 [07] x 1 1 : 1 [09] x 8 (3.9 x 32mm) [08] x 8 [10] x 4 (4 x 12mm) 100cm Chimney Hood GB IE Cooker Hood 04 FR Hotte Aspirante

More information

White - Non Illuminated Art no White - Cool White LED Art no.32600

White - Non Illuminated Art no White - Cool White LED Art no.32600 Cyclone Inline Fans White - Non Illuminated Art no.33300 White - Cool White LED Art no.32600 White - Warm White LED Art no.33800 Chrome - Non Illuminated Art no.33400 Chrome - Cool White LED Art no.32700

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Lo-Carbon SELV Tempra

Lo-Carbon SELV Tempra Lo-Carbon SELV Tempra THROUGH THE WALL HEAT RECOVERY FAN Installation and Wiring Instructions DRAFT Stock Ref. N 444368 Pullcord. (SVP) 444369 Timer. (SVT) 444370 Humidistat -Timer Pullcord. (SVHTP) 220-240V~50Hz

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

ART cm Island Curved Glass

ART cm Island Curved Glass ART28101 90cm Island Curved Glass [01] x 1 [02] x 1 [03] x 1 [04] x 1 [05] x 4 [06] x 1 [07] x 1 [08] x 1 [09] x 4 [10] x 4 [11] x 1 [12] x 4 (6x70mm) [13] x 4 (6.3x17x2mm) [14] x 8 (4x12x1mm) [15] x 4

More information

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Installation and Maintenance Instructions Retain for future reference 3. To remove the impeller, unscrew the central screw with a 7mm nut runner

More information

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz abc EXTRACTOR HOOD Please read all the instructions carefully before starting the installation Model Stock Ref Napoli 120812 Napoli Plus (white) 436083 Napoli Plus (Silver) 436084 230 / 240V 50Hz PLEASE

More information

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models: ico eco15 72683501 ico15 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. VA100 Lo-Carbon RANGE 100mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 31 59 - LP 44 31 60 - XP 44 31 61 - LT 44 31 62 - XT 44 31 63 - LHTP 44 31 64 - XHTP 220-240V~50Hz PLEASE

More information

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent TM Contour Fan Xpelair Simply Silent TM Contour Fan Installation and Maintenance Instructions C4S (92960AW) / C4R (92961AW) C4TS (92962AW) / C4TR (92963AW) C4PS (92964AW) / C4PR (92965AW) C4HTS (92966AW) / C4HTR (92967AW)

More information

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

USER MANUAL. ICON60H Version 00. Vertical Glass Hood USER MANUAL ICON60H Version 00 Vertical Glass Hood [02] x 1 [01] x 1 [03] x 1 [04] x 1 [07] x 1 [05] x 1 [08] x 9 [06] x 1 [09] x 9 (4 x 30mm) [10] x 2 (3 x 10mm) Cooker hood Let's get started... These

More information

D100, D125 & D150. Installation Instructions

D100, D125 & D150. Installation Instructions D100, D125 & D150 Installation Instructions 100mm 125mm 150mm 34 l/s (124 m 3 /h) 50 l/s (180 m 3 /h) 61 l/s (277 m 3 /h) IP22/IP24 IP22 IP22 40W 60W 20W 23W 25W 40 C 40 C 40 C kg 1.3 kg 1.4 kg 1.5 kg

More information

User Manual for your GEH6017 & GEH9017 Cooker Hood

User Manual for your GEH6017 & GEH9017 Cooker Hood User Manual for your GEH6017 & GEH9017 Cooker Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of

More information

60cm Chimney Extractor

60cm Chimney Extractor 60cm Chimney Extractor LAM2401 HJA2480 User & Installation Guide Contents Page Environmental note 3 IMPORTANT SAFETY INFORMATION 4 6 Specifications of your extractor 7 8 Dimensions 7 Specifications 7-8

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

GEH9026G Cooker Hood

GEH9026G Cooker Hood User Manual for your GEH9026G Cooker Hood 90 cm Chimney Hood in Stainless Steel NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

A GUIDE TO SELECTING THE RIGHT FAN

A GUIDE TO SELECTING THE RIGHT FAN A GUIDE TO SELECTING THE RIGHT FAN BATHROOM EXTRACTOR FAN: SELECTION GUIDE FAN REGULATIONS WHAT THE LAW STATES New Zealand Building Code G4 Ventilation (summarised): Buildings shall have a means of collecting

More information

360 Surface Mount Ceiling PIR Light Controller

360 Surface Mount Ceiling PIR Light Controller 360 Surface Mount Ceiling PIR Light Controller Model: SLW360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS 360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER Cat No. SLFM360 INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The SLFM360 utilises passive infrared technology to detect heat radiation of moving human

More information

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien AMCHD36SS/ AMCHD44SS/ INDEX WARNINGS AND REQUIREMENTS... 3 RECOMMENDATIONS AND SUGGESTIONS... 6 DIMENSIONS

More information

Xpelair Simply Silent DX150

Xpelair Simply Silent DX150 English Xpelair Simply Silent DX150 Installation and Maintenance Instructions DX150S (93070AW) DX150R (93071AW) DX150TS (93072AW) DX150TR (93073AW) DX150PS (93074AW) DX150PR (93075AW) DX150HTS (93076AW)

More information

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers Ventilation xial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible ucting Fixing Kits xternal Grilles Hand ryers Telesales Hotline 01582 544 544 9 Ventilation T extractor fans

More information

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Installation and Wiring Instructions Stock Ref. N 427485B (P) 427486B (T) 427487B (HT) 427488B (TM) FAN UNITS 12V DC SELV (CLASS III) CONTROLLERS

More information

CG60/ 70/ 80/ 90/ 100 SS/BK

CG60/ 70/ 80/ 90/ 100 SS/BK CG60/ 70/ 80/ 90/ 100 SS/BK GB IE [01] x 1 [02] x 1 [03] x 1 [04] x 2 [05] x 1 [06] x 1 [07] x 1 [08] x 4 [09] x 4 [10] x 1 [11] x 6 1 : 1 [12] x 4 [13] x 6 (3.9 x 32mm) [14] x 4 (3.4 x 10mm) CG60/ 70/

More information

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER CARVER - CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER 1:0 SPECIFICATIONS Water capacity Water connections Water supply 9 litres (2 gallons)

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz VA 150 A, VA 150 P WINDOW EXTRACT FAN Installation and Wiring Instructions VA150 P STOCK Ref: 152110B VA150 A STOCK Ref: 153110B 220-240V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE

More information

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent TM DX100 Fan Xpelair Simply Silent TM DX100 Fan Installation and Maintenance Instructions DX100R (93005AW) / DX100S (93025AW) DX100TR (93006AW) / DX100TS (93026AW) DX100PR (93007AW) / DX100PS (93027AW) DX100HTR (93008AW)

More information

Xpelair Simply Silent DX100

Xpelair Simply Silent DX100 Xpelair Simply Silent DX100 English Nederlands Installation n and Maintenance Instructions Installa en Onderho ru DX100R (93005AW) DX100S (93025AW) DX100TR (93006AW) DX100TS (93026AW) DX100HPTR (93009AW)

More information

Installation and Operating Manual Drying Cabinet

Installation and Operating Manual Drying Cabinet Drying Cabinet TS-4175 WW CONTENTS THIS USER MANUAL & DATA PLATE DETAILS Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS Page 8 MAINTENANCE INSTRUCTIONS

More information

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use. 9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use. Contents: Section 1: Options. Page 2 Section 5: Wiring instructions Page 2 & 3

More information

Silhouette Installation and Wiring Instructions

Silhouette Installation and Wiring Instructions Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

Lucci Designer Hi Flow Exhaust Fan

Lucci Designer Hi Flow Exhaust Fan USE AND CARE INSTRUCTION INSTALLATION INSTRUCTION Lucci Designer Hi Flow Exhaust Fan SKU# 200265&200267 MXSQ8PW(200mm) SKU# 200266&200268 MXSQ10PW(250mm) Dear Customers, Thank you for selecting a LUCCI

More information

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction

More information

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 EKF EC kitchen extract fan range Installation and Wiring Instructions Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS.

More information

CLASSIC-100. Instruction leaflet. Instruction leaflet

CLASSIC-100. Instruction leaflet. Instruction leaflet CASSIC-100 Instruction leaflet Instruction leaflet CASSIC-100 AXIA EXTRACTOR FAS Suitable for bathroom applications Thank you for placing your confidence in EnviroVent by buying this product. It has been

More information

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

TEMPAIR 3 IN 1 EXHAUST FAN SKU# & TEMPAIR 3 IN 1 EXHAUST FAN SKU# 200290 & 200291 CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. WARRANTY - This product is covered by a 3 year warranty. The warranty is from

More information

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

BWT6.3GL Cooker Hood 60 cm Glass chimney hood User Manual for your BWT6.3GL Cooker Hood 60 cm Glass chimney hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get

More information

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h User Guide Model: 10324 (200mm) - Extraction Rate: 340m 3 /h Model: 10326 (250mm) - Extraction Rate: 490m 3 /h Electrical Rating: 230~240 V. 50 Hz. Welcome Safety Thank you for buying this Fan. Even if

More information

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit CYFA-C EXTRACT FAS 230V/24V DC SEV Surface and Semi-Recessed Mounted Domestic Fans ISTAATIO AD MAITEACE The EMC Directive 2014/30/EU The ow Voltage directive 2014/35/EU * IPX4 SECTIO 1.0 ITRODUCTIO CYFA-C

More information

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact: For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2

More information

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12 Vent-Axia Svara Multifunctional app controlled fan Important Information 2 Installation and Wiring Instructions 3- Accessories 2 Pin Code 2 6 2 Ø99 Ø77 Important: READ THESE INSTRUCTIONS BEFORE COMMENCING

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components. 1.0 Introduction The dmev 2 speed axial extract fan has been designed for continuous ventilation for kitchens or wet rooms and should be installed using 100mm dia. ducting. The unit can be installed in

More information

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. 01 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall, ceiling, inline or window mounted You must ensure that any emissions

More information

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models: ELEGANCE Low Carbon Fan with EC Motor Installation and Operating Instructions 6 models: - SAP Appendix Q Eligible 3 speed continuous running - timer - humidity control - SELV - low voltage for all domestic

More information

ECOLEC PANEL HEATERS GENERAL NOTES.

ECOLEC PANEL HEATERS GENERAL NOTES. GENERAL NOTES. ECOLEC heating products are specifically designed to give you comfortable, controllable warmth when and where you need it. PLEASE READ THESE NOTES BEFORE INSTALLATION AND RETAIN FOR FUTURE

More information

FF3 INDUSTRIAL ELECTRIC FAN HEATER PRODUCT MANUAL GENERAL SAFETY. Models Covered: FF3 ~ FF3T ~ FF3R 230v 13A Plug ~ 110v 16A / 32A Plug

FF3 INDUSTRIAL ELECTRIC FAN HEATER PRODUCT MANUAL GENERAL SAFETY. Models Covered: FF3 ~ FF3T ~ FF3R 230v 13A Plug ~ 110v 16A / 32A Plug Also available:- Ductable 3 Phase Fan Heaters:- FF13 415v - 16A 415v 3PH + Earth Supply (No Neutral required.) FF29 415v - 32A 415v 3PH + Earth Supply (No Neutral required.) FF42 415v - 63A 415v 3PH +

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7 VA100 SEV 12 RAGE Installation and Wiring Instructions Stock Ref. VA100SV12 VA100SVX12 VA100SVXT12 VA100SVH12 VA100SVXH12 VA100SVXHT12 25 81 10D 25 83 10D 25 84 10D 25 81 12E 25 83 12E 25 85 12B FA UITS

More information

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX Green Line CMX Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions Model: CMX These instructions must be given to the householder DO NOT SWITCH OFF THE UNIT

More information

ISCG90SS _03 ISCG90SS

ISCG90SS _03 ISCG90SS ISCG90SS 60900355_03 ISCG90SS GB IE [01] x 1 [02] x 1 [03] x 1 [04] x 8 [05] x 1 [06] x 4 [07] x 1 [08] x 1 [09] x 1 [10] x 4 [11] x 4 [12] x 1 [13] x 4 (6x70mm) [14] x 8 (6.3x17x2mm) 1 : 1 [15] x 4 (3.9x18mm)

More information

User and maintenance manual

User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS HIGHLY IMPORTANT. This manual and

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

200W Frostwatch Radiant Heater Operation Manual

200W Frostwatch Radiant Heater Operation Manual LEVFW200 200W Frostwatch Radiant Heater Operation Manual REMOVE ALL PACKAGING MATERIALS FROM THIS PRODUCT BEFORE USING IT LEVFW200 200W Frostwatch Radiant Heater IMPORTANT: Read these instructions fully

More information

BT16.4SS-HK BT19.4SS-HK Cooker Hood

BT16.4SS-HK BT19.4SS-HK Cooker Hood BT16.4SS-HK BT19.4SS-HK Cooker Hood User Manual for your Baumatic User Manual for your Baumatic BT16.4SS-HK 60 cm Chimney Hood BT19.4SS-HK 90 cm Chimney Hood NOTE: This User Instruction Manual contains

More information

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Titon CME1 Q Plus Mechanical Extract Ventilation Unit Titon CME1 Q Plus Mechanical Extract Ventilation Unit Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents This is the Product Manual for the Titon CME1 Q Plus Introduction...................................

More information

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance. CAN60 / CAN60SV 60901870_01 CAN60_CAN60SV GB IE WARNING: Read the instructions before using the appliance. [01] x 1 [02] x 1 [03] x 2 [04] x 1 1 : 1 [05] x 4 (4x 32mm) [6] x 2 (3x 12mm) Cooker hood GB

More information

EVP61/91/101/121. Extractor. Installation, use and maintenance.

EVP61/91/101/121. Extractor. Installation, use and maintenance. EVP61/91/101/121 Extractor Installation, use and maintenance www.cda.eu Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER Thank you for choosing a quality Redring product manufactured by

More information

18W Round LED Wall/Ceiling Light with Microwave Sensor

18W Round LED Wall/Ceiling Light with Microwave Sensor 18W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDMR18WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

USER INSTRUCTIONS PRE- PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODELS: K240 90CM

USER INSTRUCTIONS PRE- PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODELS: K240 90CM USER INSTRUCTIONS PRE- PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODELS: K240 90CM and 100CM Britannia Living, Glen Dimplex Home Appliances, Eastern Rise, Trentham Lakes, Stoke-on-Trent

More information

KADO LUX LED EXHAUST FAN 200

KADO LUX LED EXHAUST FAN 200 page 1 of 5 272mm 240mm 170mm 272mm 221mm 98mm Dimensions are nominal measurements only. SPECIFICATIONS Recommended use Material Colour availability Fascia Size Weight Domestic, Hotel and Commercial ABS

More information

EZT90BL Extractor. Installation, Use and Maintenance.

EZT90BL Extractor. Installation, Use and Maintenance. EZT90BL Extractor Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.eu

More information

Centrifugal extract and condensation control fans

Centrifugal extract and condensation control fans Approvals: BEAB CE 3yr Guarantee Zone 1 Zone 2 The Premier range of pressure developing fans is designed specifically for domestic applications, where longer duct runs are required. Key features Type:

More information

Xcell 270 Longlife DC wholehouse heat recovery unit

Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270 Longlife DC wholehouse heat recovery unit Installation and maintenance instructions Xpelair Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270, Xcell 270BP Please leave this leaflet

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent Contents 01 Introduction 2 02 Technical Specification 3-4 03 Wiring Diagrams 5-6 04 Safety 7-8 05 Controls 8 06 Box Contents 9 07 Tools Checklist 10 08 Installation Steps 11 09 Installation 12-22 10 RF

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150 Wall Mounted Fan Flue System boiler Appr. nr. B 94.04 A - CE 0063 AQ 2150 Phone numbers: Installer Service Engineer Serial N Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS Please read

More information

HW3 Handwash Installation and Operating Instructions

HW3 Handwash Installation and Operating Instructions HW3[16]instructions 10/12/15 14:05 Page 1 HW3 Handwash Installation and Operating Instructions IMPORTANT SAFEGUARDS SPECIFICATION: HW3 RATING: 230-240V, 3000W, ~50Hz; DIMENSIONS: 170w x 190h x 80d mm;

More information

Drying Cabinet Installation and Operating Manual

Drying Cabinet Installation and Operating Manual Drying Cabinet Models:- ETS-1900H ETS-1900TR CONTENTS ABOUT THE USER MANUAL Page 2 IDENTIFICATION DATA PLATE Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS

More information

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

CMX-S. Company name: Contact: Tel:   Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions V EN T IL AT ION V EN T IL AT ION CMX-S Installer contact details: Company name: Contact: Tel: Email: Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions These

More information

Xpelair Simply Silent DX100B

Xpelair Simply Silent DX100B Xpelair Simply Silent DX100B Installation and Maintenance Instructions English DX100BR (92997AW) DX100BS (93017AW) DX100BTR (92998AW) DX100BTS (93018AW) DX100BHTR (92999AW) DX100BHTS (93019AW) DX100BHPTR

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST LUX 3-IN-1 HEAT LIGHT EXHAUST page 1 of 5 505mm 360mm 330mm 148mm 195mm 10mm 530mm Dimensions are nominal measurements only. SPECIFICATIONS Recommended use Fascia Material Colour availability Weight Domestic,

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information