9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

Size: px
Start display at page:

Download "9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use."

Transcription

1 9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use. Contents: Section 1: Options. Page 2 Section 5: Wiring instructions Page 2 & 3 Section 2: First steps Page 2 Section 6: Installation Page 3 & 4 Section 3: Warnings Page 2 Section 7: Testing Page 5 Section 4: General Information Page 2 Section 8: User Information Page 5 Note to installer: Please leave these instructions with the occupier of the premises.

2 Options: Model Application Features Extract Capacity MV230p Pullcord operation. Air extraction only. MV230AR MV300AR For domestic or commercial purposes Wall, window or ceiling mounted. Automatic, with slow moving, delayed action shutters. Reversible air flow (intake/extraction) Variable speed control. Supply 750 m 3 /hr 208 l/sec 230v 50Hz 42W 1400 m 3 /hr 389 l/sec 230v 50HZ 102W 2. FIRST STEPS: Unpack the fan and check that the unit is correct and has not been damaged in transit. If any item is damaged, do not use but report the damage to your supplier. 3. WARNINGS: 3.1 The fan must not be used in an ambient temperature higher than 40 O C (104 O F). 3.2 An adequate supply of fresh air must be provided if the fan is to be fitted in a room 3.3 All electrical connections must comply with BS7671: It is a requirement in this standard that all appliances shall be installed via a double pole switched, fused connection unit having switch contact openings of at least 3mm and fitted with a 3amp fuse. It is recommended that the installation is carried out by a qualified electrician. 4. GENERAL INFORMATION: 4.1 Fans (except the MV230P) incorporate a neon indicator to show when the fans are operating. 4.2 The fans are suitable for installation into a window, wall, veiling, panel and sealed double glazing units (with relevant accessories). 4.3 The fans comply with BS3456 and BS EN The fans are CE marked and comply with the EC Directive EMC 89/ In case of failure, disconnect the supply and contact Airflow Service Department on It is recommended that the fan is disconnected from the supply when not in use. 5. WIRING INSTRUCTIONS: 5.1 Disconnect the mains electricity supply before making any wiring connections. 5.2 Refer to the wiring diagrams and work out a suitable wiring scheme, taking into account existing wiring, junction boxes and cable entry to the fan. 5.3 The fan is double insulated and does not require earthing. 5.4 The fans are wired using a plug/socket arrangement located in a terminal box mounted on motor/fan assembly (item 3a in Fig.3). Remove the terminal block cover by removing the single screw and hinging the cover aside. Remove the female section of the terminal block and wire as shown in the wiring diagram. Replace the female section of the terminal block and terminal cover before replacing the front cover.

3 5.5. Fig.1 Wiring diagram for Model MV230P (Pullcord operation) Fig.2 Wiring diagram for Models MV230AR and MV300AR (With speed controller). 6. INSTALLATION: Refer to Fig Cut a hole for the fan exhaust outlet in the required position, sized as follows: - Models MV230/MV230AR: 254mm to 258mm diameter Models MV300AR: 324mm to 329mm diameter. 6.2 Remove the front cover (item 1 Fig.3) by pressing the black buttons on each side of the fan (or unscrewing the buttons on the Model MV300AR fan). 6.3 Unscrew the four screws (item 2) and remove the motor/fan assembly (item 3). 6.4 Remove outside grille (item 15) by unscrewing the brass slotheaded nuts (item 4) recessed in the main casing (item 5) 6.5 WINDOW INSTALLATION: Suitable for window thicknesses up to 20mm Position the outside grille (item 15) on the outside of the window, line up the main casing (item 5) and tighten into position by means of screwing back the slotheaded nuts (item 4). WALL INSTALLATION: 1) Fix wall rods (item 10) to the outside grille (item 15) using M5 brass nuts (item 12: 4 off for MV230P/MV230AR fans and 6 off for MV300AR fan). 2) Insert the wall plate (item 7) over the extension rods (using holes closest to the spigot) ensuring that the spigot is protruding into the hole. 3) Fix a wall sleeve (of 250mm dia. For MV230P/MV230AR fans and 315mm dia. For MV300AR fan not supplied) over the wall rods to mate with the spigots on the outside grille (item 15) and the wall plate (item 7)

4 4) Line up the main casing (item 5) with the wall rods and tighten into position with the brass slotheaded nuts (item 4). CEILING INSTALLATION: A ceiling kit consisting of an additional wall plate and ducting is required for this installation. 1) Cut a hole (as detailed in section 6.1) in both the ceiling and outside all. 2) Position the outside grille (item 15) on the outside of the wall, line up the additional wall plate on the inside wall with its spigot facing inwards and fix into position with M5 brass nuts. 3) Use the wall plate (item 7) as a template to mark four fixing holes (those closest to the spigot) and drill M5 clearance. 4) With the wall plate (item 7) on the other (loft) side of the ceiling, and with its spigot pointing away from the ceiling, fix the main casing of the fan (item 5) to the wall plate with the fan casing inside the room. 5) Fix ducting between the wall plate spigot attached to the outer wall and the wall plate spigot attached to the ceiling. 6.6 After installation, manually check that the fan impeller rotates easily. 6.7 Feed in wire (2-core for MV230/P fan and 4-core for MV230AR?MV300AR fans with speed controller) through the black grommet on the top of the fan. 6.8 Remove the screw which keeps the terminal block cover (item 3a) in position on the motor/fan assembly (item 3). 6.9 Connect the fan as per the appropriate wiring diagram in section Re-position the motor/fan assembly (item 3), tightening into position with 4-off screws (item 2) 6.11 Ensure that the front cover louvers are in their open position before replacing the front cover.

5 7. TESTING: 7.1 When the installation is complete, switch on the electricity supply 7.2 Model MV230P (pullcord operation) Check that operating the pullcord will alternately start and stop the fan. With the fan operating, check that an adequate amount of air is being exhausted (i.e. no blockages are present) and fan noise is not excessive. 7.3 Models MV230AR/MV300AR (with speed controller: refer to Fig.4). 1) With speed controller rotary switch S3 set to position 1 (slowest speed), set switch S1 (on/off switch) to position 1. Check the following: - Switch A1 illuminates The neon on top of the fan illuminates The front cover shutters open slowly after a delay (taking approximately 30 to 45 seconds to fully open) 2) Turn switch S3 clockwise to position 2 and note that the fan speed increases. Repeat for positions 3, 4 and 5. With S3 in position 5 (highest fan speed) check that the fan noise is not excessive. 3) With S3 in position 5, select other position on switch S2 and note that the direction of the fan impeller reverses. 4) Select position 0 on switch S3 and check that fan becomes stationary, but the shutters remain open. 5) Switch S1 to position 0 (off) and note that the front cover shutters slowly close (taking approximately 1-2 minutes to fully close). 8. USER INFORMATION: 8.1 Operation. To operate the fan follow the procedure in section 7. If your Airflow fan fails to work correctly, contact the installer or failing that, contact Airflow Service Department on High Wycombe (01494) Safety. When installed and used according to these instructions, your Airflow fan is completely safe. The materials employed do not constitute a hazard. 8.3 Cleaning. The exterior of the fan may be cleaned with a dry cloth The interior of the fan should also be cleaned occasionally. First, disconnect from the mains electrical supply, remove the front cover and then the motor/fan assembly as described in sections 6.2 & 6.3. The front cover may be washed with a mild detergent but the fan body must be wiped with a clean dry cloth. On no account must the motor be immersed in water or strong solvents used. The statements and opinions contained in this document are made and expressed in good faith. Whilst every effort has been made to provide reliable information, Airflow Developments Ltd do not hold themselves responsible for possible errors of an editorial or other nature, however caused. Should you require a more detailed specification for a product described herein, please contact our Sales Department. We reserve the right to change the specification for any model or item described in this publication. Airflow Lufttechnik GmbH Postfach 1208, D Rheinbach, Germany. Telefon:02226/ , Telefax: 02226/ Airflow Developments Limited Lancaster Road, Cressex Business Park, High Wycombe, Bucks. HP12 3QP. England. Tel: +44 (0) Fax: +44 (0) infor@airflow.co.uk. Web: airflow.com Airflow Lufttechnik GmbH o.s. Praha, Hostynska 520, Praha 10 Maleoice, Czech Republic Telefon: , Telefax: Airflow Developments Limited Airflow developments Limited reserve the right, in the interest of continuous development, to alter specifications without prior notice. All orders are accepted subject to our conditions of sale which are available on request.

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections Now includes a Pressure Safety Switch and easier Electrical Connections Flue Dilution Fans VISIT US AT www.airflow.com UK SALESLINE 0845 330 1047 Specialists in Air Movement Technology SAFETY - NEW Differential

More information

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models: ico eco15 72683501 ico15 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico

More information

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW 90411215-Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW DESTINATION The in-line mixed flow fans with channels' diameters ranging from 100 to 150 mm are designed for installation in the ventilating systems

More information

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Installation and Maintenance Instructions Retain for future reference 3. To remove the impeller, unscrew the central screw with a 7mm nut runner

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ

More information

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS. INSTALLATION/OPERATING INSTRUCTIONS FOR C100 & C100T Thank you for purchasing a quality Extractor fan from Greenbrook. Please read these instructions fully prior to initial use. Every effort has been made

More information

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models: ELEGANCE Low Carbon Fan with EC Motor Installation and Operating Instructions 6 models: - SAP Appendix Q Eligible 3 speed continuous running - timer - humidity control - SELV - low voltage for all domestic

More information

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use Internal/External Wall/Window Fan Range GX6 Installation and maintenance instructions Retain for future use A GLASS WINDOW B C D ( 6 see F ) 13 E1 E2 E3 G1 G2 G3 G4 H I GB Xpelair GX6, GXC6, GXC6T, GX6HT

More information

Installation & Operating Instructions

Installation & Operating Instructions Installation & Operating Instructions For 4 / 100mm Centrifugal s Models: K612 & K612T Thank you for purchasing a quality Centrifugal from GreenBrook. Please read these instructions fully prior to initial

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

EVG Extractors. Manual for Installation, Use and Maintenance

EVG Extractors. Manual for Installation, Use and Maintenance EVG Extractors Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W :

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz VA 150 A, VA 150 P WINDOW EXTRACT FAN Installation and Wiring Instructions VA150 P STOCK Ref: 152110B VA150 A STOCK Ref: 153110B 220-240V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Window & Roof Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456165A (9" WW) 456168A (9" RF) 456173A (12" WW) 456176A (12" RF) WIRELESS 456169A (9" WW) 456172A (9"

More information

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Microbox DC Models MBOX 125/2DC MBOX 125/2DC204 "Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204 Continuous Mechanical Extract Ventilation Unit with Low Energy DC Motor - for domestic and commercial use Installation, Operating and Maintenance Instructions

More information

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan Simply Silent Contour 4 (100mm) Axial Extraction Fan Suitable for bathrooms, toilets, shower and utility rooms Controls humidity, odours and mould growth Sleek low-profile design, wall or ceiling mounting

More information

Lo-Carbon T-series Window & Roof Models

Lo-Carbon T-series Window & Roof Models Lo-Carbon T-series Window & Roof Models Installation & User Instructions WIRED 456165A (9 WW) 456168A (9 RF) 456173A (12 WW) 456176A (12 RF) WIRELESS 456169A (9 WW) 456172A (9 RF) 456177A (12 WW) 456180A

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 16 24-100B 44 16 25-100T 44 16 26-100HT 44 16 28-150B 44 16 29-150T 44 16 30-150HT 220-240V~50Hz

More information

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING! Installation and Maintenance Opus OK / Genie KF Kitchen Extract Unit uaire imited Western Industrial Estate Caerphilly, Mid Glamorgan CF8 XH Telephone: 09 088 59 Facsimile: 09 088 70 Email: info@nuaire.co.uk

More information

Installation & Operating Instructions

Installation & Operating Instructions Installation & Operating Instructions For 12V Extractor s Models: (4 ) G510SELV, (6 ) G242SELV For 12V Controllers Models: 12VFC, 12VFCT & 12VFCHS Thank you for purchasing a quality 12V Extractor & Controller

More information

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or Domestic AC Fans 230V Installation and Operating Guide 230V AC Base Models: ico15 72683501 ico15c 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components. 1.0 Introduction The dmev 2 speed axial extract fan has been designed for continuous ventilation for kitchens or wet rooms and should be installed using 100mm dia. ducting. The unit can be installed in

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. VA100 Lo-Carbon RANGE 100mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 31 59 - LP 44 31 60 - XP 44 31 61 - LT 44 31 62 - XT 44 31 63 - LHTP 44 31 64 - XHTP 220-240V~50Hz PLEASE

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

EH0533 Indoor Climate Control

EH0533 Indoor Climate Control EH0533 Indoor Climate Control 2.8 kw of cooling, 2.9 kw of heating Air Conditioning Efficient heating (air-source heat-pump) Cooling Remote control Suitable for low-wall installation No external unit required

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent TM Contour Fan Xpelair Simply Silent TM Contour Fan Installation and Maintenance Instructions C4S (92960AW) / C4R (92961AW) C4TS (92962AW) / C4TR (92963AW) C4PS (92964AW) / C4PR (92965AW) C4HTS (92966AW) / C4HTR (92967AW)

More information

Xpelair Simply Silent DX150

Xpelair Simply Silent DX150 English Xpelair Simply Silent DX150 Installation and Maintenance Instructions DX150S (93070AW) DX150R (93071AW) DX150TS (93072AW) DX150TR (93073AW) DX150PS (93074AW) DX150PR (93075AW) DX150HTS (93076AW)

More information

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1 Instruction Manual M6627 / Version 7.4 Slide Drying Bench MH6616 MH6616X1 Please take your time to read this Instruction Manual in order to understand the safe and correct use of your new Electrothermal

More information

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Titon CME1 Q Plus Mechanical Extract Ventilation Unit Titon CME1 Q Plus Mechanical Extract Ventilation Unit Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents This is the Product Manual for the Titon CME1 Q Plus Introduction...................................

More information

OP40R 40cm Remote Control Pedestal Fan

OP40R 40cm Remote Control Pedestal Fan OP40R 40cm Remote Control Pedestal Fan Instruction Manual Important Safety Instructions 1. Read all instructions. 2. Disconnect the power plug before dismantling, assembling or before cleaning. 3. Avoid

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

Microbox Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions "Microbox" Continuous Mechanical Extract Ventilation Units Installation, Operating and Maintenance Instructions 5 models rectangular and/or round spigots domestic and commercial use Page 2 "MICROBOX" -

More information

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz abc EXTRACTOR HOOD Please read all the instructions carefully before starting the installation Model Stock Ref Napoli 120812 Napoli Plus (white) 436083 Napoli Plus (Silver) 436084 230 / 240V 50Hz PLEASE

More information

Drying Cabinet Installation and Operating Manual

Drying Cabinet Installation and Operating Manual Drying Cabinet Models:- ETS-1900H ETS-1900TR CONTENTS ABOUT THE USER MANUAL Page 2 IDENTIFICATION DATA PLATE Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. 01 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall, ceiling, inline or window mounted You must ensure that any emissions

More information

CLASSIC-100. Instruction leaflet. Instruction leaflet

CLASSIC-100. Instruction leaflet. Instruction leaflet CASSIC-100 Instruction leaflet Instruction leaflet CASSIC-100 AXIA EXTRACTOR FAS Suitable for bathroom applications Thank you for placing your confidence in EnviroVent by buying this product. It has been

More information

Lo-Carbon SELV Tempra

Lo-Carbon SELV Tempra Lo-Carbon SELV Tempra THROUGH THE WALL HEAT RECOVERY FAN Installation and Wiring Instructions DRAFT Stock Ref. N 444368 Pullcord. (SVP) 444369 Timer. (SVT) 444370 Humidistat -Timer Pullcord. (SVHTP) 220-240V~50Hz

More information

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent TM DX100 Fan Xpelair Simply Silent TM DX100 Fan Installation and Maintenance Instructions DX100R (93005AW) / DX100S (93025AW) DX100TR (93006AW) / DX100TS (93026AW) DX100PR (93007AW) / DX100PS (93027AW) DX100HTR (93008AW)

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

irconcentre.co.uk airooncentre.co.uk

irconcentre.co.uk airooncentre.co.uk Installation and maintenance instructions DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet/Bathroom

More information

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user Copperad QA/IOM/58 Issue 2 1 GENERAL 1.1 GENERAL DESCRIPTION This manual

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR Installation and operating instructions LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord Safety extra low voltage toilet/bathroom 100mm fan range Integral

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

FLUEBOOST. flueboost 350 gas fire model

FLUEBOOST. flueboost 350 gas fire model 350 FLUEBOOST flueboost 350 gas fire model The flueboost is a box shaped unit with in line spigots for the flue connection, a pressure switch to ensure safe operation and plug-in electrical fittings for

More information

HR200WK Through the wall Heat Recovery Ventilator

HR200WK Through the wall Heat Recovery Ventilator HR200WK Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions Stock Ref No:- HR200WK 14120020 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Wall & Panel Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456166A (9" WL) 456167A (9" PL) 456174A (12" WL) 456175A (12" PL) WIRELESS 456170A (9" WL) 456171A (9"

More information

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 Your new Cooker Hood Using your new Cooker Hood is very simple. Nevertheless, to get the best results it is important that you read

More information

Xpelair Simply Silent DX100

Xpelair Simply Silent DX100 Xpelair Simply Silent DX100 English Nederlands Installation n and Maintenance Instructions Installa en Onderho ru DX100R (93005AW) DX100S (93025AW) DX100TR (93006AW) DX100TS (93026AW) DX100HPTR (93009AW)

More information

SAX. Window & Wall Fans

SAX. Window & Wall Fans SAX Window & Wall Fans features & benefits The SAX is a stylish, high performance range of axial flow fans which provides powerful extract of air through windows, walls, ceilings and panels for a variety

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5 230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall,

More information

Turbo Inline Fan, White - Non Illuminated Art no.33500

Turbo Inline Fan, White - Non Illuminated Art no.33500 Quality Bathroom Products Turbo Inline Fan, White - Non Illuminated Art no.33500 Turbo Inline Fan, White - Cool White LED Art no.300 Turbo Inline Fan, White - Warm White LED Art no.34000 Turbo Inline Fan,

More information

EVP61/91/101/121. Extractor. Installation, use and maintenance.

EVP61/91/101/121. Extractor. Installation, use and maintenance. EVP61/91/101/121 Extractor Installation, use and maintenance www.cda.eu Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 EN OPERATION MANUAL CONTENTS Introduction 3 General 3 Safety rules 3 Transportation and storage rules 3 Manufacturer's warranty 3

More information

KUDOS. Instruction leaflet

KUDOS. Instruction leaflet KUDOS Instruction leaflet KUDOS RAGE CETRIFUGA EXTRACTOR FAS Suitable for bathroom, kitchen and utility room applications Thank you for placing your confidence in EnviroVent by buying this product. It

More information

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts. FAT2000/R ow Energy Positive Input Ventilation Unit Installation and Maintenance The EMC Directive 204/0/EU The ow Voltage Directive 204/5/EU.0 ITRODUCTIO The uaire Drimaster/Flatmaster range has been

More information

Xpelair Simply Silent DX100B

Xpelair Simply Silent DX100B Xpelair Simply Silent DX100B Installation and Maintenance Instructions English DX100BR (92997AW) DX100BS (93017AW) DX100BTR (92998AW) DX100BTS (93018AW) DX100BHTR (92999AW) DX100BHTS (93019AW) DX100BHPTR

More information

200W Frostwatch Radiant Heater Operation Manual

200W Frostwatch Radiant Heater Operation Manual LEVFW200 200W Frostwatch Radiant Heater Operation Manual REMOVE ALL PACKAGING MATERIALS FROM THIS PRODUCT BEFORE USING IT LEVFW200 200W Frostwatch Radiant Heater IMPORTANT: Read these instructions fully

More information

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents Introduction...................................

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Dyna-Form Air. Alternating Pressure Relief Overlay System

Dyna-Form Air. Alternating Pressure Relief Overlay System Dyna-Form Air Alternating Pressure Relief Overlay System 1 Contents Introduction 3 Cleaning 10 General Warnings 4 Control Unit 10 Unpacking / Setting Up 5 Air Filter 10 Setting Up 6 Mattress Cover 11 Connect

More information

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised Natural Ventilation e-stack A-Series Ventilation System for Buildings with Atria Installation and Maintenance The EMC Directive 004/108/EC The Low Voltage directive 006/95/EC Important Notes to Designers

More information

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881 User, Installation and Servicing Instructions Panther Static Hot Cupboards G1, G2 and G3 Panther Static Hot Cupboard User Instructions Installation Remove all packaging and protective coatings from both

More information

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers Ventilation xial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible ucting Fixing Kits xternal Grilles Hand ryers Telesales Hotline 01582 544 544 9 Ventilation T extractor fans

More information

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide .0 Introduction The dmevh is a speed axial extract fan has been designed for continuous ventilation for kitchens or wet rooms and should be installed using 00mm dia. ducting. Speed settings are fixed at

More information

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12 Vent-Axia Svara Multifunctional app controlled fan Important Information 2 Installation and Wiring Instructions 3- Accessories 2 Pin Code 2 6 2 Ø99 Ø77 Important: READ THESE INSTRUCTIONS BEFORE COMMENCING

More information

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80 Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried

More information

EVX101 Extractor Installation, Use and Maintenance

EVX101 Extractor Installation, Use and Maintenance EVX101 Extractor Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.eu

More information

Installation and Wiring Instructions

Installation and Wiring Instructions Powerline (TDF) Installation and Wiring Instructions TDF32014 TDF38014 TDF42014 TDF48014 TDF38034 TDF42034 TDF48034 TDF52034 TDF52036 TDF60034 TDF60036 PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR UK-PR ISS-B

PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR UK-PR ISS-B PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR PROZONE 80MG MODEL ONLY UK-PR80-061107-ISS-B INTRODUCTION Thank you for purchasing PROZONE. Please read these instructions before attempting installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Through the Wall Fan "Whisper Wall" Ventilating Fan FV-08WQ READ AND SAVE THESE INSTRUCTIONS Please read instructions carefully before attempting to install, operate or service

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

Manual for installation, use and maintenance MEH & MEP. Chimney Extractors. year. parts + 1 year labour guarantee.

Manual for installation, use and maintenance MEH & MEP. Chimney Extractors. year. parts + 1 year labour guarantee. Manual for installation, use and maintenance MEH & MEP Chimney Extractors year parts + 1 year labour guarantee www.matrixappliances.co.uk Important The CDA Group Ltd cannot be held responsible for injuries

More information

Adjustable Electric Heater

Adjustable Electric Heater Adjustable Electric Heater User instructions - please keep for future reference GS11 V1.0 Technical information Power Supply: 220-240V ~ 50Hz Wattage: 900W/1200W/20W Element Type: Halogen Life of Lamp:

More information

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL SWP (Models SWP08 through SWP20) OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

DUKA S7. Bathroom fan and Heat mover 8-11 User and Installation instructions. 2 Mounting illustrations 3 Parts. dukaventilation.dk

DUKA S7. Bathroom fan and Heat mover 8-11 User and Installation instructions. 2 Mounting illustrations 3 Parts. dukaventilation.dk DUKA S7 2 Mounting illustrations 3 Parts Bathroom fan and Heat mover 8-11 User and Installation instructions DUKA00001 45 Serie nr.: DUKA00001 Model: S7 230V AC 50Hz, 3W, Class II, IP44 45 Serie nr.: DUKA00001

More information

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T EN Trimbox Mixed Flow Fans TP220T TP221T TP222T TP223T Product Manual ventilation systems Safety Information Important Information Important: read these instructions fully before the installation of this

More information

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Warnings, Safety Information and Guidance

Warnings, Safety Information and Guidance EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,

More information

MEH600/900 MEP600/900 Extractors. Manual for Installation, Use and Maintenance

MEH600/900 MEP600/900 Extractors. Manual for Installation, Use and Maintenance MEH600/900 MEP600/900 Extractors Manual for Installation, Use and Maintenance Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this

More information

White - Non Illuminated Art no White - Cool White LED Art no.32600

White - Non Illuminated Art no White - Cool White LED Art no.32600 Cyclone Inline Fans White - Non Illuminated Art no.33300 White - Cool White LED Art no.32600 White - Warm White LED Art no.33800 Chrome - Non Illuminated Art no.33400 Chrome - Cool White LED Art no.32700

More information

DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061

DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061 DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061 Page 1 of 8 Introduction This instruction manual covers the operation of versions of the Domestic Ice Machine Model TS-061 manufactured after April

More information

360º Surface Mount Ceiling PIR Light Controller

360º Surface Mount Ceiling PIR Light Controller 360º Surface Mount Ceiling PIR Light Controller Model: PDRS1500 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information