Technical Data Manual

Size: px
Start display at page:

Download "Technical Data Manual"

Transcription

1 Technical Data Manual Mini Tower ENVIRONMENTAL CONTROL Liebert Keeping Business in Business LPN: SLE MT TDM E.3_r1 (10/99) HPN:

2

3 Table of Contents System nomenclature 1 Introduction 2 Standard features - all models 3 Optional features - all models 10 Technical data - all models 14 Electrical data - all models 16 Sound data - all models 17 Dimensional drawings 18

4

5 System nomenclature The nomenclature for Mini Tower packaged (compressor in the indoor unit) and split (compressor located in a condensing unit) systems is as follows: TS/TSF 06 A U X Humidifier: M = Humidifier X = No humidifier Air pattern: U = Upflow D = Downflow System type: A = Air cooled W = Water cooled G = Glycol cooled C = Chilled water Model size: Capacity in kw (Nominal) TS = Mini Tower Packaged TSF = Mini Tower Split (Air Cooled only) TS/TSF 06 A U M Model size System type Air pattern Humidification Mini Tower 04 4kW nom. cap. A Air cooled D Downflow M Humidifier 06 6kW nom. cap. W Water cooled U Upflow X No humidifier 07 7kW nom. cap. G Glycol cooled 09 9kW nom. cap. C Chilled water 11 11kW nom. cap. AIR (Packaged) AIR (Split) WATER GLYCOL CHILLED WATER TS04AUX/ADX TSF6AUX/ADX TS04WUX/WDX TS04GUX/GDX TS07CUX/CDX TS04AUM/ADM TSF6AUM/ADM TS04WUM/WDM TS04GUM/GDM TS07CUM/CDM TS06AUX/ADX TSF9AUX/ADX TS06WUX/WDX TS06GUX/GDX TS11CUX/CDX TS06AUM/ADM TSF9AUM/ADM TS06WUM/WDM TS06GUM/GDM TS11CUM/CDM TS09AUX/ADX TS09WUX/WDX TS09GUX/GDX TS09AUM/ADM TS09WUM/WDM TS09GUM/GDM SLE MT TDM E.3_r1 (10/99) 1

6 Introduction Precision environmental control may be defined as the simultaneous control of air temperature, humidity, distribution and cleanliness on a continual, around-the-clock basis. Conventional building or comfort systems, as they are called, are not designed for this 24-hour, year-round usage; they lack the ability to provide the precision and reliability or close control that is so critical to many applications. All units are built in accordance with European directives 98/37/CE (89/392/CEE; 91/368/CEE; 93/68/CEE), 89/336/CEE; 73/23/CEE. The Liebert Air Conditioning Quality System is approved by LRQA in accordance with the standards UNI EN ISO 9001: Each unit is supplied complete with a Test Certificate and Declaration of Conformity. All Mini Tower units carry the CE mark and fully comply with European Directives concerning mechanical, electrical and electromagnetic safety. Liebert technology and energy efficiency Liebert has become a world leader in precision environmental control systems by providing maximum energy efficiency without compromising precision and reliability. Liebert takes a no-compromise approach to environmental control system design. All enhancements to energy efficiency are designed to reduce operating time of key components. This is accomplished by taking advantage of alternate sources of cooling when available or, by reducing compressor work load when the heat load in the critical space is lower. Applications The Mini Tower unit is ideally suited for precision close control of the following types of environment: Data centres Telecommunications Industrial applications Office environments System types The Mini Tower is available in a number of configurations: Air cooled Two system types are available: Packaged This comprises an indoor unit (consisting of an evaporator coil, scroll compressor, direct driven fan, electric reheat and filter section) and an outdoor air cooled condenser. Indoor Unit TS04A TS06A TS09A Matching Condenser* HCA07 HCA10 HCA14 *: Quoted at 32 o C outside ambient temperature. For other ambients, consult the Condenser Technical Data Manual (P/N SLE CD TDM). Split This comprises an indoor unit (consisting of an evaporator coil, direct driven fan, electric reheat and filter section) and an outdoor condensing unit (complete with scroll compressor). Indoor Unit TSF6A TSF9A *: 32 o C outside ambient temperature. Water/Glycol cooled Matching Condensing Unit* MMC08 MMC10 This comprises of an indoor unit (consisting of an evaporator coil, scroll compressor, plate condenser, direct driven fan, electric reheat and filter section) and an outdoor drycooler. Note: This product may not be suitable for all open water tower applications as good quality water is essential for correct operation. Consult Liebert Hiross Applications Engineering for further details. Chilled Water This comprises of an indoor unit only (consisting of a chilled water coil, 3-way valve, direct driven fan, electric reheat and filter section). The unit is supplied with chilled water from a central building chiller or other chilled water source. 2 SLE MT TDM E.3_r1 (10/99)

7 Standard features - all models General The Mini Tower series comprises both direct expansion units and chilled water units. Cooling capacities range from 4 to 11 kw. Direct expansion units are equipped with compliant scroll compressors. The design of the scroll compressor, ensures a constant refrigerant pressure, thus improving reliability, energy consumption and sound emission. The Mini Towers compact design, facilitates a minimum unit footprint, allowing the unit to be installed in very confined areas, the unit is fully serviceable from the front. Access/maintenance Routine maintenance access to refrigerant circuit components, the compressor, liquid reservoir, thermal expansion valve, sight glass, filter dryer etc. is available through the front panel of the unit. Service access to the air filter is also through the unit front panel. All other components of the machine, the fan, humidifier, electric panel, electronic controller PCB, electric reheats etc. are accessible through the front and grille panels. Customer connections to the refrigerant circuit (hot gas and liquid line), mains power supply, humidifier water supply and condensate drain lines are located in the lower right-hand-side of the unit. Cabinet The cabinet is manufactured from primed and treated steel, it is then degreased and painted in RAL 9018 using dry powder epoxy resin paint (the return air grille is finished in NCS 3502 coloured paint). The paint finish is easily cleaned and is hard wearing to give maximum protection. The unit has removable panels which give access to all internal components from the front of the unit. The panels are insulated with 12mm, 30 kg/m 3 density foam which reduces noise emission and heat loss. The foam is a self-extinguishing material in compliance with the following standards: ASTM D 1992, MVSS302, UL94 Class 0. A safety microswitch is fitted to the front panel of the unit. The microswitch deactivates the unit if the front panel is removed. The edges of the panels are fitted with seals to prevent air loss and to keep noise levels to an absolute minimum. Filter section The guaranteed efficiency is EU3, (Eurovent EU4/5 (30% efficiency), equivalent to G3 - CEN Standard). An optional EU4 filter (G4) is available on request. The air filter is mounted on the face of the evaporator coil and is easily accessed/replaced by removing the front panel. The filter is made of open-cell foam and is designed to minimise the air pressure drop while maintaining maximum filter efficiency. Fan and motor assembly The unit is fitted with a direct-drive, double-inlet forwardcurved, galvanized-steel, centrifugal fan. The fan impeller is statically and dynamically balanced and equipped with sealed-for-life bearings. The fan is mounted on vibration-absorbing rubber supports to reduce vibration transmission between the fan and the unit frame. This vibration attenuation helps to keep noise emission to a minimum. The fan motor is a single-phase, 5-speed motor complete with thermal overload protection. Each speed of the motor produces a different airflow through the unit, refer to the Technical Data section for specific model/airflow data. Each unit is wired for two different airflows, a cooling airflow and a lower, dehumidification airflow. The controller will switch the unit to the lower airflow during the dehumidification cycle. Electric reheat The single-stage, three element reheats are of rigid, fin-tubular design that have extended operational life. The reheat has ample capacity to maintain room dry-bulb conditions during a system call for dehumidification. The low-watt density, phase balanced, electrically enclosed elements are surrounded by the tube and fins, reducing sheath temperatures and eliminating ionisation. Reheat control is of the ON-OFF type. The reheat is provided with a manual reset, reheat safety thermostat, to disable the reheat in the event of high temperature. SLE MT TDM E.3_r1 (10/99) 3

8 Standard features - all models (continued) Microprocessor controls The Microface environmental control system is microprocessor based and can be programmed to match the unique needs of any application. The processor integrates the separate mechanical and electrical components into a state-of-the-art conditioned space support system that controls and monitors temperature, humidity, air flow and air cleanliness. The control system offers a tailored and well proven advance in reliability and control flexibility allowing the unit to modify its performance in response to changing critical space conditions. The controller allows local monitoring and programming of the following room conditions: Temperature ( o C) Temperature setpoint (5.0 o C 40.0 o C in steps of 0.1 o C) Temperature sensitivity (1.0 o C-10 o C in steps of 0.1 o C) Humidity (%RH) Humidity setpoint (20%RH - 80%RH in steps of 1%) Humidity sensitivity (5%RH - 20%RH in steps of 1%) The parameters are enunciated using symbols and text on an LCD display. Normal operating modes are indicated by symbols on the display. Alarm conditions activate a visual indicator. The following alarms are standard: High temperature Low temperature Fan failure High pressure alarm (compressorised systems only) Low pressure alarm - (compressorised systems only) Electrical reheat high temperature Memory failure Common alarm Other alarms are also available when the relevant option is ordered with the unit (e.g. if a humidifier is ordered with the unit, the High Humidity, Low Humidity etc. alarms are enabled). For a full list of all the options and alarms available with the Microface controller, refer to the Microface Controller Operation Manual (P/N SLE MF OM). The controller also incorporates a sequential auto-restart timer, allowing field adjustable time delays to be applied to unit restart after a power loss (or other shutdown). The timers allow multiple units to be restarted while limiting instantaneous inrush current. Electrical panel The electric panel is located at the top-front of the unit in an airtight compartment. The electrical panel contains the MCB s, contactors, transformer, controller PCB and overload relays etc. Each high voltage system component is provided with a separate over-current protective device. All high-voltage components are touch protected by means of a plastic cover. Electrical design is in accordance with UNI / EN All models are supplied as standard for operation at 400V/3ph/50 Hz. Models TS04A, TS06A, TSF6A, TS07C and TS11C can be supplied for 230 V/1ph/50 Hz operation to special order. Packaging As standard, the units are wrapped in plastic film to protect painted surfaces, enclosed in a cardboard box and mounted on a wooden pallet. On request, for sea transport etc., the units can be packed in wooden crates or cases complete with silicon desiccant. Warranty clauses The warranty does not cover any damage or malfunction of the unit which may occur during or as a result of operating the unit outside of the specified application limits. Liebert does not accept responsibility for any damage caused by improper use of the product. 4 SLE MT TDM E.3_r1 (10/99)

9 Standard features - all models (continued) Refrigerant circuit - dx models Each unit in the range has a single refrigerant circuit. The circuit consists of a compressor, a thermal expansion valve, a liquid line sight glass, a filter dryer, an evaporator coil and high and low pressure switches. Liebert recommends the installation of a non-return valve (supplied as an option, on request) on the liquid line from the condenser, to protect the compressor from unexpected refrigerant migration. All low temperature parts of the refrigerant circuit are insulated as standard. Compressors The fully hermetic compliant scroll compressor incorporates several safety features for protection during normal and the occasional abnormal operating conditions. They are: Self resetting overloads to sense excessive currents and temperatures. An internal pressure relief valve which limits discharge pressure to protect mechanical parts. Motor insulation that is resistant to chemical attack. Rubber mounting to ensure reduced compressor noise and vibration. Schraeder connections are fitted to the unit for service access. Refrigerant R22 HCFC is the standard refrigerant used in the Mini Tower range. An optional Green refrigerant, R407C is available to special order. In this case the compressor is supplied with ester oil instead of mineral oil. Air cooled units are shipped with a nitrogen holding charge. Evaporator coil The evaporator coil is constructed from copper tubes with aluminium fins to ensure maximum heat transfer. It is designed to maximise the available surface area resulting in low face velocities, low internal air pressure drops and the high sensible heat ratios. A corrosion resistant drain pan is provided on all models. Air Cooled Condenser Condensing Unit Outdoor Indoor Outdoor Indoor Packaged air cooled systems Split air cooled systems SLE MT TDM E.3_r1 (10/99) 5

10 Standard features - all models (continued) Sight glass Refrigerant line sight glasses serve as a means of quick visual inspection to determine if there is moisture in the system and if the system is properly charged. Filter-dryer Liquid line filter-dryers ensure a clean, moisture-free refrigerant system for extended component life. The filter drier is suitable for use with standard R22 and optional Zero ODP refrigerant R407C. Expansion valve The externally equalised, adjustable, thermostatic expansion valve smoothly controls refrigerant flow during varying indoor heat loads and outdoor ambient temperatures by controlling evaporator superheat. Safety controls Each compressor has a manual-reset high pressure switch for high pressure protection and a high pressure alarm circuit to warn of high system pressures, allowing corrective action to be taken before a significant loss of temperature control occurs. The low pressure switch is auto-resetting and detects low pressure conditions such as loss of refrigerant charge. The pressure switch calibration values are shown in the Installation, Operation & Maintenance Manual supplied with the machine. Packaged air-cooled models Air cooled condensers A matching Liebert air cooled condenser with fan speed control should be ordered with the unit. The range includes condensers with axial fans and centrifugal fans. Details of standard condenser selections for 32 o C ambient are provided in this manual, full technical details of all condensers for all outdoor ambients are available in the Condenser Technical Data Manual, (P/N SLE CD TDM). Note: Condenser selections/performances for each outdoor ambient are based on calculated data. The actual selection of a condenser should always be verified on the basis of the specific working conditions on each site. Water/glycol cooled models Water/glycol-cooled Mini Tower units are fitted with a high pressure plate heat exchanger and a 2-way water regulating valve (rated at 1030kPa (150psi)) to maintain head pressure. Plate heat exchanger The compact brazed plate heat exchanger consists of a number of parallel stainless steel pressed plates, the pressing pattern being inverted on alternate plates. In this way, the ridges on adjoining plates form contact points and the refrigerant and fluid move in contra-flow through alternate channels. The plate heat exchanger is designed to operate at a maximum working pressure of 30 bar (3000 kpa) (factory-tested to 40 bar (4000 kpa)). The units operate with mains water, cooling tower water or water in a closed circuit with an external drycooler. When operating in a closed circuit, it may be necessary (depending on outside temperatures) to add mono-ethylene glycol to prevent the water freezing in winter, refer to the unit Installation Manual for applicable percentages. A pump is used to circulate water (water/glycol) through the unit (not supplied by Liebert). If mains water or tower water is used, it is recommended to fit a mechanical filter on the water line to protect the plate heat exchanger against possible impurities contained in the water (for plate heat exchanger cleaning, refer to the Installation Manual). Note: Water cooled units may not be suitable for some open cooling tower applications as good water quality is essential. Contact Liebert Applications Engineering for details. Water regulating valve A 2-way water regulating valve is fitted as standard and is designed to operate with fluid working pressures of 10.1 bar (1010 kpa). The valve operates with a maximum fluid temperature of 77 o C. Drycooler A matched Liebert drycooler should be ordered with the unit. The range includes condensers with axial fans and centrifugal fans. Details of standard drycooler selections for 32 o C ambient are provided in this manual, full technical details of all drycoolers for all outdoor ambients are available in the Drycooler Technical Data Manual, (P/N SLE DC TDM). Note: Drycooler selections/performances for each outdoor ambient are based on calculated data. The actual selection of a drycooler should always be verified on the basis of the specific working conditions on each site. 6 SLE MT TDM E.3_r1 (10/99)

11 Standard features - all models (continued) Split air-cooled models Condensing unit Cabinet The cabinet is manufactured from zinc coated steel, it is then de-greased and painted in Pearl White (RAL7032) dry powder epoxy resin paint. The paint finish is easily cleaned and is hard wearing. The cabinet has been designed specifically for outdoor applications, all materials, fittings and components have been selected to provide maximum weather protection, durability and security (vandal-proof cabinet). The unit has removable panels (a special key is required) which give access to all internal components. The condenser air inlet is through the rear of the unit and discharges through the front. A metal safety grid prevents accidental contact with the fan and the coil. The compressor is located in the side of the Condensing unit, separated from the airstream. Condenser coil The condenser coil is manufactured from refrigeration quality copper tubes with mechanically bonded aluminium fins, and is vertically mounted. Fan/motor assembly The condensing unit is equipped with a single axial fan with integral motor, it is statically and dynamically balanced. The fan impeller and casing are made from zinc-coated steel to protect against corrosion. The direct drive motor includes sealed-for-life bearings. The fan motor is IP54 rated and complete with internal thermal protection. The fan motor is controlled by a pressure switch to maintain a steady condensing temperature. Fan speed control A factory fitted solid state fan speed controller is installed to maintain the refrigerant condensing pressure. The controller varies airflow through the condenser to maintain a constant pressure. The advantages of fan speed control are two-fold. Higher reliability of the system due to less starts/stops of the compressor and a lower noise level because the fan is running at a lower speed, mainly during night-time. Compressor The fully hermetic compliant scroll compressor incorporates several safety features for protection during normal and the occasional abnormal operating conditions. They are: Self resetting overloads to sense excessive currents and temperatures. An internal pressure relief valve which limits discharge pressure to protect mechanical parts. Motor insulation that is resistant to chemical attack. Rubber mounting to ensure reduced compressor noise and vibration. The compressor is fitted with a crankcase heater as standard. They maintain minimum refrigerant temperature and are energised while the unit is powered and the compressor is off. Schraeder valves are fitted to the compressor for service access. Refrigerant R22 HCFC is the standard refrigerant used in this range. Condensing units suitable for use with an optional Zero ODP refrigerant, R407C are available to special order. Controls Pre-wired, factory installed electrical and control components include: Mains and low voltage terminals. Compressor and fan contactor. Factory pre-wired high pressure switch. Electrical design is in accordance with UNI / EN Sight glass Refrigerant line sight glasses serve as a means of quick visual inspection to determine if there is moisture in the system and/or if the system is properly charged. Filter-dryer Liquid line filter-dryers ensure a clean, moisture-free refrigerant system for extended component life. The filter drier is suitable for use with standard R22 and optional Zero ODP refrigerant R407C. Liquid receiver in indoor unit In split air-cooled models, a welded steel liquid receiver is provided to maintain constant and even refrigerant flow to the expansion valve, under all circumstances. It is installed in the indoor unit. Shut-off valves are fitted as standard on the inlet and outlet of the receiver to assist maintenance of the circuit, if required. A suitably rated pressure relief valve is installed on the liquid receiver. The valve is equipped with a threaded connection to allow the refrigerant to be discharged outside of the conditioned space, if required. SLE MT TDM E.3_r1 (10/99) 7

12 Standard features - all models (continued) Chilled water systems Cooling coil The chilled water coil is manufactured from refrigeration quality copper tubes with mechanically bonded aluminium fins. Coils are circuited from a header to ensure low water pressure drops. It is designed to maximise the available surface area resulting in low face velocities, low internal air pressure drops and the high sensible heat ratios. A corrosion resistant drain pan is provided on all models. 3-way control valve The chilled water valve provides on/off control action in response to room temperature and humidity as sensed by the microprocessor. This is a slow acting, motorised ball-valve offering on/off control without water-hammer. The valve is rated to 862 kpa (125 psi). Operating limits - dx models Mini Tower dx units are designed for operation within the following working limits (the limits are applicable to newly commissioned machines which have been correctly installed and maintained). Indoor operating range TS04A/W/G from 18.0 C, 45% R.H. to 30.0 C, 55% R.H. TS06A/W/G from 18.0 C, 35% R.H. to 30.0 C, 70% R.H. TS09A/W/G from 18.0 C, 35% R.H. to 27.0 C, 70% R.H. To minimise the possibility of water carry-over, (i.e. too much condensate on the evaporator coil leading to the formation of water droplets), it is critical to ensure that the latent load (difference between total and sensible load) does not exceed the following values: TS04A/W/G 1.4 kw TS06A/W/G 2.0 kw TS09A/W/G 2.8 kw Air flow The minimum and maximum air flows and available external static pressure are given in the Technical Data section of this manual. The fan motor thermal overload protects the unit from any damage which could result from operating outside the specified values. Voltage tolerance All models: 400 V 10% Frequency tolerance All models: 50 Hz 2 Hz. Condenser installation (packaged air cooled) Condenser above indoor unit Maximum distance between indoor unit and external air condenser: 30 meters equivalent length. Condenser below indoor unit Maximum geodetic height difference between condenser and unit: 3 meters. Condensing unit installation (split air cooled) Maximum distance between indoor unit and condensing unit: 15 meters equivalent length. Refer to the unit Installation, Operation and Maintenance for further details. Outdoor operating range Lower limit -25 C (with fan speed control in the condenser). Upper limit This is determined by the capacity of the condenser coupled to the unit (at the relevant outdoor ambient). If the limit is exceeded, the High Pressure Switch will shut the compressor down. The switch must then be manually reset after the problem has been rectified. 8 SLE MT TDM E.3_r1 (10/99)

13 Standard features - all models (continued) Operating limits - chilled water models Mini Tower chilled water units are designed for operation within the following working limits (the limits are applicable to newly commissioned machines which have been correctly installed and maintained). Indoor operating range TS07C from 18.0 C, 45% R.H. to 27.0 C, 55% R.H. TS11C from 18.0 C, 35% R.H. to 30.0 C, 70% R.H. Note: Consult Liebert Applications Engineers for use of the units outside this range. To minimise the possibility of water carry-over, (i.e. too much condensate on the evaporator coil leading to the formation of water droplets), it is critical to ensure that the latent load (difference between total and sensible load) does not exceed the following values: TS07C 1.4 kw TS11C 2.0 kw Outdoor operating range The entering chilled water temperature to the cooling coil should normally be at least 5 o C lower than the return air temperature to the cooling coil. Chilled water temperatures below 6 o C require careful unit selections. Maximum recommended water pressure: 16 bar Air flow The minimum and maximum air flows and available external static pressure are given in the Technical Data Section of this manual. The fan motor thermal overload protects the unit from any damage which could result from operating outside the specified values. Voltage tolerance All models: 400 V 10% Frequency tolerance All models: 50 Hz 2 Hz. SLE MT TDM E.3_r1 (10/99) 9

14 Optional features - all models Electrode boiler steam humidifier Provides humidification control and consists of a steam generator, steam distribution tube, fill valve, drain pump and electronic controls, located within the evaporator module. The 2.4 kw (at 380V) humidifier produces a maximum steam output of 3 kg/hr (adjustable). Note: These humidifiers should only be used where the supply water has a conductivity between 80 and 1000 S/cm and a water pressure of 0.3 to 8 bar (Max. supply water temperature 30 o C). Modulating chilled water valve Optional fully modulating (2 or 3-way) chilled water valve for close control applications. The valve body is rated for 27.5 bar (2750 kpa) operating pressure for closed systems. For high pressure open systems, consult Applications Engineering for valve and actuator selections. Plenum A 400mm high top discharge plenum, with insulated side panels and painted to match the unit colour, is available for applications where the supply air side of the unit is to be connected to a ceiling void. Plenums with discharge grilles (both fixed and adjustable) are available to special order. Fresh air kit They maintain minimum refrigerant temperature and are energised while the unit is powered and the compressor is off. Condensate pump ( units with humidifier) The condensate pump is provided for mounting either under the raised floor or local to the unit and is complete with sump, motor, pump and automatic control. The pump has a capacity of 548 l/hr at a head of 6 meters of water. (max. water temperature 82 o C). Condensate pump (units without humidifier) The condensate pump is provided for mounting within the unit and is complete with an internal sump which will switch the pump motor on when water is detected. When water has been removed from the sump, the pump will automatically stop A fresh air supply kit is available comprising a spigot connection for 100mm I.D. duct hose (hose not supplied by Liebert) and a cylindrical intake filter. 3-way water regulating valve Flow Rate Ltrs/Hour Lift in metres A 3-way water regulating valve can be fitted and is designed to operate with fluid working pressures of 10.1 bar (1010 kpa). The valve is rated for a maximum fluid temperature of 77 o C. Note: This valve is supplied loose for fitting externally to the machine and comes complete a 1m capillary line Horizontal Distance Pumped in metres Crankcase heaters Crankcase heaters are available as an option with all compressorised models (standard on split air-cooled models). Figure 1 - Condensate pump capacity chart (units without humidifier) 10 SLE MT TDM E.3_r1 (10/99)

15 Optional features - all models (continued) Refrigerant non-return valves Refrigerant non-return valves for air-cooled units are available as an option. The valve is installed on the liquid line, close to the condenser and mounted vertically. High efficiency filters Optional high efficiency filters are available for all models. The high efficiency filters are interchangeable with the standard filters. The filters are EU4 (Eurovent 4/5), filtration class G4 (CEN standards). Filter clog switch An adjustable diaphragm-type, differential pressure switch can be fitted to initiate a change filter alarm when a pre-selected pressure drop across the filter bank is exceeded. Hot water reheat The economical hot water reheaters have the capacity to maintain dry bulb conditions when the system is calling for dehumidification. The reheats are controlled by a 3-way (on/off) valve from the microprocessor control panel. The system is completely pre-piped and includes an air bleed valve. The reheat coil is single row, constructed of copper tubes with aluminium fins. The coil is tested to a pressure of 30 bar. A hot water thermostat (provided by the customer) is used in the valve control sequence to determine the availability of reheat capacity. Water detection options The water detection sensor LT410 contains an isolated switch that closes when water (or other conductive liquid) is detected by the sensor probes. The sensor is hermetically sealed, robust and should be fitted in the location where water problems might occur. The LT460 is a water detection cable. The cable is placed on the floor around the base of the unit. It will generate an alarm (via contact closure) if water (or other conductive liquid) comes in contact with the cable. Full details are available from your Liebert representative. Smoke alarm The smoke detector will activate an audible alarm and stop the unit if smoke is detected in the return air. The sensor is an optic smoke detector (Tyndall effect) which is insensitive to light or air movement. Firestat The firestat deactivates the unit when the return air temperature is too high. The firestat can be mounted in the unit or remotely, consult Liebert Applications Engineers for further details. Environmental Alarm Package The Electronic Environmental Alarm Package (EEAP) is a remote temperature and relative humidity sensor (additional to the internal sensor) connected to the unit controller. The sensor can be installed up to 20m from the unit and generates an alarm if the temperature or the relative humidity exceeds one of the 4 user-set limits: High Temperature Limit (Adjustable from 10 C to 50 C) Low Temperature Limit (Adjustable from 0 C to 30 C) High Humidity Limit (Adjustable from 30% to 99%) Low Humidity Limit (Adjustable from 10% to 70%). Floorstand Floorstands are available in a range of heights: 230mm, 305mm, 380mm, 460mm, 530mm and 610mm. Each height of floorstand is adjustable over a 38mm range. The floorstands permit installation and connection of the unit prior to installation of the raised floor. Turning vane A factory installed turning vane may be specified to direct the air as required within the floorstand. SLE MT TDM E.3_r1 (10/99) 11

16 Optional features - all systems (continued) Hiromatic graphic* The Hiromatic Graphic sets even higher standards in purpose-designed control systems for precision air-conditioning. It simultaneously monitors the critical space and signals alarms either locally or remotely. The graphics screen displays all the major parameters, including symbolic representation of unit functions, such as heating, cooling etc.; in addition temperature and humidity variations with time can be presented graphically on the screen. All diagnostic procedures, including the checking and calibration of input and output signals, and of the microprocessor itself, can be run from the front panel Features Backlit LCD graphics display User interface via pushkeys Battery-backed clock for date/time and real time functions Password control for setpoints, unit/control setup and service functions Graphics display of temperature and humidity over a 24 hour period The Hiromatic Graphic is specifically designed for group management of a number of individual units although it can be used in stand-alone applications. Due to its large graphical display area, combined with exceptional contrast, it allows the user to move around easily within the network of connected unit controllers (up to max. 16). It is possible to control/adjust each connected units operations from a single point. The controller is menu-driven and user menu s are available in 10 languages. The controller records the last 120 events (Alarms, Warnings etc.) occurring in the system along with a Graphic Data Record for each connected unit. The Graphic Data Record displays the temperature and humidity readings from each unit for the last 24 hours (stored since the last start-up of the unit). The Hiromatic Graphic controls date and time functions using them as operating information for the customer and as a reference whenever a status change occurs, logging the status change in the Status Report. Details of the event which occurred, the date and time at which the event occurred are also stored. Using buffered RAM, the Hiromatic also stores the operating hours of each component (compressor, fan, electric heaters, humidifier etc.) for each connected unit. A feature uniquely available with the Hiromatic controller is Sleep Mode Sleep Mode allows units to be programmed to switch on and off at different times of the day, and on different days of the week. *: The Hiromatic Graphic is supplied in a wall-mounted box for remote installation. BEMS Interface The Hiromatic Graphic allows units on a network to be integrated with the Hirolink Communications Bus when an RS422 card is installed at the back of Hiromatic. Hiromatic can control up to 8 Microface units in this configuration and communicate the relevant data to Hirolink. Hirolink works as a communications manager between the Hiromatic Graphic and Microface units and industry standard field busses and protocols used in Building Management Systems such as Mod-Bus, J-Bus, Satchwell, etc. Note: For full details of the controller, refer to the Hiromatic Graphics Controller Manual, (P/N SLE HG OM). Special packaging Where the unit is to be transported by sea or in other cases where heavy duty packaging is required, special crating is available. This can consist of either a wooden crate over the standard carboard/bubble wrap packaging or the entire unit can be encased in a wooden box. Alternative refrigerant R407C An optional green refrigerant, R407C can be supplied with all compressorised models. The compressor is filled with a special ester oil required for R407C. Air cooled units are filled ex-factory with a holding charge of dry nitrogen. Water and glycol units are charged with R407C. 12 SLE MT TDM E.3_r1 (10/99)

17 Optional features - all systems (continued) Special colour Where required by the installation, the unit can be supplied in any RAL colour. Minimum order quantities may apply, consult Liebert Applications Engineering. Extended warranty The standard, parts-only, warranty is 15 months from the unit ship date. This can be extended to 21, 27 or 39 months as an option. Flow switch The flow switch is available as an option with chilled water units. It is fitted as standard on the chilled water inlet line but can be fitted on the bypass-leg (3-way valves) or between the valve and the coil, if required by the application. The switch is of the paddle type and is complete with volt-free contacts. It can be wired to activate an alarm and/or shut down the unit should the chilled water supply be interrupted. Epoxy coated fins - condensing unit If the condensing unit is to be installed in a potentially corrosive environment or close to salt water, epoxy/acrylic coated fins are available to maximise the operating life of the condenser coil. Capacity will be derated, contact Liebert Applications Engineering for specific details. SLE MT TDM E.3_r1 (10/99) 13

18 Technical data - all models Gross Cooling 1 Capacities Data in kw MODEL 26 ºC DB, 50% RH 24 ºC DB, 50% RH 24 ºC DB, 45% RH 22 ºC DB, 50% RH TS04 Air Cooled TS06/ TSF6 TS09/ TSF9 Water 2 Cooled Glycol Cooled Chilled 3 Water TS04 TS06 TS09 TS04 TS06 TS09 TS07 TS11 Total Sensible Total Sensible Total Sensible Total Sensible : Capacity data is based on gross cooling capacity. To obtain nett figures, deduct the fan motor kw. 2 :24 o C Entering Water Temperature and 43 o C Condensing Temperature 3: 7.2 o C Entering Water Temperature and 5.5 o C Temperature Rise 4 : Air cooled capacities, packaged/split, are stated at 32 o C outside ambient. Fan Section - Single Fan, Direct Drive Air Flow m 3 /h (m 3 /s) 1600 (0.44) 1800 (0.5) 2300 (0.64) 1600 (0.44) 1800 (0.5) 2300 (0.64) 1600 (0.44) 1800 (0.5) 2300 (0.64) 1800 (0.5) 2300 (0.64) Ext. Static Press. Pa Evaporator Coil - Copper Tube/Aluminium Fin Chilled Water Coil Face Area m Rows of Coil Face Velocity m/s Flowrate/Pressure Drop Water Cooled Condensers Chilled Water Coil Flowrate (l/s) Pressure Drop (kpa) SLE MT TDM E.3_r1 (10/99)

19 Technical data - all models (continued) Pipe Connections Model Chilled Water Return Chilled Water Supply Hot Gas Line Liquid Line Water Connections Humidifier Supply Steam Distributor Drain Humidifier & Coil Drain TS04 A in in. 3 - TS06 /TSF6 A in in. 3 - TS09 /TSF9 A in in.3 - TS 04 W/G in. BSP 2 TS 06 W/G in. BSP 2 TS 09 W/G in. BSP 2 TS 07 C 3 4 in. BSP in. BSP TS 11 C 3 4 in. BSP in. BSP BSP = British Standard Pipe; 1 : Male Thread Connections; 2 : Female Thread Connections; 3 : Male flare connector, 4 : O.D. Copper Condensing Unit Section 1 4 in. OD 1 4 in. Male Flared MMC mm 4 18mm MMC mm 4 18mm " Female BSP MMC08 MMC10 Air Volume m 3 /h (m 3 /s) 5510 (1.53) 5510 (1.53) Face Area m Face Velocity m/s Rows of Coil 4 4 Weight kg Weight (unpacked) - indoor unit Model TS04/6/9A 1 TSF6/9A TS04/6/9W & G TS07/11C Weight kg : For air cooled condenser weights and pipe sizes, refer to the Condenser Technical Data Manual P/N SLE CD TDM. Reheat/Humidifier section - all models Electric Reheat - Single Stage, Fin Tubular Total reheat capacity at 400V 3kW (3 number 1kW (400V) elements) Electrode Boiler Steam Humidifier Max. Capacity 3.0 kg/h Filter - all models Cleanable, open cell foam EU3 Filter 1 no. SLE MT TDM E.3_r1 (10/99) 15

20 Electrical data - all models Mini Tower Electrical Ratings Model Compressor* Fan Motor Electric Reheat Steam Humidifier FLA kw OA FLA kw FLA kw FLA 230/1/50 400/3/50 Nom. 230/1/50 230/1/50 400/3/50 Nom. 400/3/50 Nom. 400/3/50 TS04A/W/G TS06A/W/G TS09A/W/G TS07C TS11C TSF6A TSF9A MMC MMC Electrical Ratings - Other Matching Equipment Air Cooled Condenser Drycooler Indoor Model Model FLA Model FLA 230/1/50 230/1/50 TS04A HCA TS06A HCA TS09A HCA TS04G DSL TS06G DSL TS09G DSL *: Quoted for R22 Note 1 : FLA = Full Load Amps Note 2: OA = Operating Amps Note 3 : Nom. = Nominal Note 4 : All units require a Neutral. Note 5: Condenser/Drycooler selection based on an ambient temperature of 32 o C. For other ambient temperatures, consult the Drycooler or Condenser Technical Data Manuals (P/N s SLE DC TDM & SLE CD TDM). 16 SLE MT TDM E.3_r1 (10/99)

21 Sound data - all models Sound Pressure Levels db(a) TS04/6/9 A/W/G Standard Air Volumes TS/04A/W/G TS06A/W/G TS09A/W/G TSF6/9 A&TS07/11C Standard Air Volumes TSF6A & TS07C TSF9A & TS11C Sound Pressure Level db(a) At 1.5m Free Field Sound Pressure Level db(a) At 1.5m Free Field 3 Air Volume m /h ( thousands) 3 Air Volume m /h (t housands) Notes: 1. Sound pressure levels (at 1.5m) were measured in a room with a reverberation time of seconds and a net volume of 270m For unit standard air volumes and capacities, refer to the unit capacity section of this manual. 3. For more information on air volumes other than standard, consult the Liebert Applications Engineering Department. 4. The above graphs are for a constant 25 Pascals external static pressure, all figures are quoted at standard operating conditions. 5. Free field sound pressure levels are calculated from the dbx & dby/ dbz Sound Power components. 6. General Tolerance 1.5 db(a) Sound Power Levels db (re: 1 pw) Model Hz k 2k 4k TS04A/W/G TS06A/W/G TS09A/W/G TSF6A & TS07C TSF9A & TS11C dbx dby dbz dbx dby dbz dbx dby dbz dbx dby dbz dbx dby dbz Figure 3 - Measurement directions for noise data Condensing units - MMC08/10 Sound Pressure level at 2m in the Free Field: MMC08: 56dB(A). MMC10: 57 db(a). Note: For condenser sound data - refer to the Condenser Technical Data Manual. SLE MT TDM E.3_r1 (10/99) 17

22 Dimensional data - air, water/glycol cooled (packaged) CONTROL DISPLAY ELECTRIC PANEL RETURN AIR RETURN AIR REMOVABLE AIR FILTER FRONT PANELS REMOVABLE REAR PANEL HUMIDIFIER (OPTIONAL) COMPRESSOR CONDENSER (WATER, GLYCOL) DIRECT DRIVE BLOWER MAINS SUPPLY INPUT & ALARM TERMINALS A A ALTERNATIVE ALTERNATIVE PIPING ENTRIES CABLE ENTRIES (REFER TO DETAIL 'A') (REFER TO DETAIL 'B') 690 END VIEW FRONT ELEVATION END VIEW FRONT VIEW LEFT RIGHT (PANELS REMOVED) SHOWING MAJOR COMPONENTS FAN DISCHARGE OPE. (DOWNFLOW UNITS ONLY) LIQUID LINE / WATER OUTLET HOT GAS / WATER INLET GRILLE DIM DISCHARGE GRILLE (UPFLOW UNITS ONLY) HUMIDIFIER SUPPLY DETAIL 'A' PIPING ENTRIES CABLE ENTRIES & (SEE DETAIL 'A') DETAIL 'B' SECTION A-A (SEE DETAIL 'B') (DIM'NS INCLUDE PANELS) DX AIR HOT GAS LIQUID LINE HUMIDIFIER SUPPLY DRAIN 1/2" 3/8" FLARE FLARE 1/4" OD 3/4" ID DX WATER WATER INLET FEMALE WATER OUTLET 3/4" BSP 3/4" BSP FEMALE HUMIDIFIER SUPPLY 1/4" OD DRAIN 3/4" ID 18 SLE MT TDM E.3_r1 (10/99)

23 Dimensional data - chilled water CONTROL DISPLAY ELECTRIC PANEL RETURN AIR RETURN AIR REMOVABLE AIR FILTER FRONT PANELS REMOVABLE REAR PANEL CHILLED WATER HUMIDIFIER VALVE (OPTIONAL) HOT WATER VALVE (OPTIONAL) DIRECT DRIVE BLOWER MAINS SUPPLY INPUT & ALARM TERMINALS A A ALTERNATIVE ALTERNATIVE PIPING ENTRIES CABLE ENTRIES (REFER TO DETAIL 'A') (REFER TO DETAIL 'B') 690 END VIEW FRONT ELEVATION END VIEW FRONT VIEW LEFT RIGHT (PANELS REMOVED) SHOWING MAJOR COMPONENTS FAN DISCHARGE OPE. (DOWNFLOW UNITS ONLY) CONDENSATE DRAIN CHILLED WATER INLET GRILLE DIM DISCHARGE GRILLE (UPFLOW UNITS ONLY) CHILLED WATER OUTLET HUMIDIFIER SUPPLY DETAIL 'A' PIPING ENTRIES CABLE ENTRIES & (SEE DETAIL 'A') HUMIDIFIER STEAM DRAIN (SEE DETAIL 'B') SECTION A-A DETAIL 'B' (DIM'NS INCLUDE PANELS) CW WATER WATER HUMIDIFIER HUMIDIFIER DRAIN OUTLET INLET SUPPLY STEAM DRAIN 3/4" BSPT 3/4" BSPT 1/4" SAE MALE MALE 1/4" OD 3/4" ID FLARE CONN SLE MT TDM E.3_r1 (10/99) 19

24 Dimensional data - air cooled (split) 20 SLE MT TDM E.3_r1 (10/99)

25 Dimensional data - air cooled condensing unit (split) FRONT VIEW SIDE VIEW REAR VIEW AIR FLOW 4 no. ø8 mm Mounting Holes AIR FLOW AIR FLOW = 887 = AIR FLOW TOP VIEW SLE MT TDM E.3_r1 (10/99) 21

26

27

28 A World Leader in Computer Support Systems. Environmental Control Power Protection Site Monitoring Liebert Corporation designs, manufactures and markets complete systems for improved uptime and performance of electronic equipment, including computer rooms, networks, medical, industrial, and other critical systems. The result is improved business operations, increased productivity and higher return on the customer's electronic equipment investment. Liebert Systems provide dependable environmental control and electrical power protection, combined with centralised monitoring. This approach represents a single-source integrated support network. Based on over two decades of experience and over 100,000 installations worldwide, Liebert is committed to offering the highest quality products and services for critical electronics. While every precaution has been taken to ensure accuracy and completeness in this manual, Liebert assumes no responsibility and disclaims all liability for damages resulting from the use of the information contained herein or any errors or omissions. Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert and the logo, are registered trademarks of Liebert Corporation. Liebert European Headquarters Liebert Europe Zona Industriale Tognana, Via Leonardo da Vinci, 8, Piove di Sacco (PD), Italy. Tel: Fax: Internet: International Headquarters Liebert Corporation 1050 Dearborn Drive, P.O. Box Columbus, Ohio USA Tel: Fax: Internet: LPN: SLE MT TDM E.3_r1 (10/99) HPN:

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons Liebert Mini-Mate2 1 To Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment

More information

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial

More information

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons Liebert Mini-Mate2 1 To Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment

More information

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity Liebert CW 26-181kW Chilled Water Cooled Precision Air Conditioning For Data Centers Precision Cooling For Business-Critical Continuity A Chilled Water Precision Cooling System That Handles The Most Demanding

More information

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons Liebert Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity The Solution For Your Cooling Needs May Be Right Above You When the need

More information

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) with refrigerant Product Description Performance and Electrical Data Dimensional Data Guide

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most

More information

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 6 Guide Specification 60 Hz S6-GS-602017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 6 Guide Specification-60

More information

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 8 Guide Specification 60 Hz S8-GS-602017.doc 2014 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 8 Guide Specification-60

More information

Condensing Units CUS 15-60

Condensing Units CUS 15-60 Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....

More information

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified Shelf Units 2, 3, and 4 ton R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

Data Aire Series Chilled Water 7 through 50 ton

Data Aire Series Chilled Water 7 through 50 ton Data Aire Series Chilled Water 7 through 50 ton ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system

More information

Liebert OVERHEAD COOLING IN A VARIETY OF CAPACITIES AND CONFIGURATIONS. Mini-Mate2. 1 to 8 Tons. Provides Precision Cooling And Humidity Control

Liebert OVERHEAD COOLING IN A VARIETY OF CAPACITIES AND CONFIGURATIONS. Mini-Mate2. 1 to 8 Tons. Provides Precision Cooling And Humidity Control GFGDFDFGFGFYUIUIYUITUYIUIUOG GFGDFDFGFGFYUIUIYUITUYIUIUOG GFGDFDFGFGFYUIUIYUITUYIUIUOG GFGDFDFGFGFG Liebert Mini-Mate2 1 to 8 Tons H e a t R e m o v a l OVERHEAD COOLING IN A VARIETY OF CAPACITIES AND

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in the late

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

Series PS6, Vertical Floor-Mount Units

Series PS6, Vertical Floor-Mount Units Series PS6, Vertical Floor-Mount Units Technical Data 60 Hz sps6em6ea.doc Dec-12 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Table of Contents Table of Contents...

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

Mission Critical Air Conditioning Systems

Mission Critical Air Conditioning Systems Mission Critical Air Conditioning Systems wall & ceiling mount Series 7 & 11 1-5 Ton Units Single Circuit Units Designed for Superior Space Utilization Series 7 1.5-2.5 tons Compact wall mounted split

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Guide Specifications for InRow Direct Expansion

Guide Specifications for InRow Direct Expansion Guide Specifications Guide Specifications for InRow Direct Expansion THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT. THIS SECTION MUST

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control

Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control Liebert Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control LIEBERT MINI-MATE2 1 TO 8 TONS Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment needs precision

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms SKY-COM HI-CAP SERIES Precise Environmental Control SKY-COM 15 & 20 TON Series Suited for Telecommunications, Laboratories and Computer Rooms GENERAL MECHANICAL SPECIFICATIONS AIRFLOW CONFIGURATION Units

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Chilled Water 7 to 211 kw

Chilled Water 7 to 211 kw Chilled Water 7 to 211 kw Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing facility

More information

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Engineering Manual ABOUT STULZ STULZ is a privately owned, global manufacturer of highly efficient temperature and humidity management

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

Close Control Air Cooled Twin Circuit Range

Close Control Air Cooled Twin Circuit Range Close Control Air Cooled Twin Circuit Range Engineering Data Manual 50/60Hz ENGINEERING DATA MANUAL 50/60Hz Index Description Page YORK Company Profile 3 This Product Range 3 Other YORK Close Control Product

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Chilled Water 7 to 211 kw

Chilled Water 7 to 211 kw Chilled Water 7 to 211 kw Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing facility

More information

Blower-YEFB-020-3R-1maxVel

Blower-YEFB-020-3R-1maxVel YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers Liebert CW 26-181kW Chilled Water Cooled Precision Air Conditioning For Data Centers LIEBERT CW A Chilled Water Precision System That Handles The Most Demanding Conditions Based on the historically reliable

More information

IPAC Air Handling Units

IPAC Air Handling Units Eaton-Williams IPAC IPAC Air Handling Units Short-form version - extracted from Section 2 of the Installation, Operation and Maintenance Manual Technical Product Guide IPAC (Invicta Precision Air Control)

More information

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

Guide Specifications PART 1 GENERAL 1.01 SUMMARY Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB 6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual Indoor Cooling Perimeter STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol Self-contained Precision Air Conditioner Utilizing EC Fan Technology

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

gforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits

gforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits gforce - R-407C Air Cooled, Water/Glycol Cooled 21-106 kw Dual Circuits 1 2 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling

More information

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

RTU. Roof Top Units 8 30 Ton. Maxi-Kool. Maxi-Kool RTU Roof Top Units 8 30 Ton www.compu-aire.com MK A-3 034 -RTU Maxi-Kool Type Air Cooled - A Chilled Water Cooled - C Glycol Cooled - G Water Cooled - W Nominal Tonnage 8 30 Ton Voltage 2-208

More information

Superchiller Water Chillers. English

Superchiller Water Chillers. English Superchiller 2000 Water Chillers English Superchiller 2000 Aircooled free cooling waterchiller The HIROSS Superchiller 2000 products are a compact air cooled chillers line with additional built-in free

More information

PRODUCT DOCUMENTATION

PRODUCT DOCUMENTATION Precision Cooling for Business Critical Continuity Liebert Hiross HPM 4 99 kw Indoor Room Cooling Units AWFDH Versions Liebert Hiross HPM PD 273147 14.07.200 PRODUCT DOCUMENTATION Introduction Liebert

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data â NetworkAIR TM CM Series Precision Air-Conditioning Units 60 Hz Technical Data Contents Available Models................................. 1 Spot-cooled 1 Ducted 1 System Configurations.............................

More information

EDPAC International Close Control Air Conditioning Products E

EDPAC International Close Control Air Conditioning Products E EDPAC International Close Control Air Conditioning Products E4.19-04-04-04 The Ranges of Close Control Products comprise of : Close Control Modular Range : Modular units, using R407C/R410A & Chilled Water

More information

Liebert PDX and PCW Thermal Management Systems

Liebert PDX and PCW Thermal Management Systems Liebert PDX and PCW Thermal Management Systems 3 to 8 Ton (11 to 29 kw) Nominal Capacity, Upflow and Downflow, 60 Hz, Air-, Water-, Glycoland Chilled-water-cooled Models System Design Catalog Technical

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data NetworkAIR Precision Air-Conditioning Units 60 Hz TM AFX Series Technical Data Contents Available Models................................. 1 Downflow 1 Upflow front-return 1 Upflow rear-return 1 Indoor

More information

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered

More information

Liebert Datamate: R-407C Parts Manual

Liebert Datamate: R-407C Parts Manual Liebert Datamate: R-407C Parts Manual While every precaution has been taken to ensure accuracy and completeness in this manual, Vertiv Co. asssumes no responsibility, and disclaims all liability for damages

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

Liebert HIROSS for Telecom

Liebert HIROSS for Telecom Liebert HIROSS for Telecom HIGH PERFORMANCE AIR CONDITIONING Thermal Management for BTS & Remote Nodes GB H I W A L L The Hiwall PO series (Packaged Outdoor unit), matches its compact structure with plain

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

Computer Room Air-Conditioning 60 Hz. Technical Data

Computer Room Air-Conditioning 60 Hz. Technical Data TM Computer Room Air-Conditioning 60 Hz 35 150 kw (10 45 tons) Technical Data Contents Overview.............................................................. 1 Scalable Solution for Critical Environments.................................

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information