GeoFurnace GEOTHERMAL HEAT PUMPS. July 1, Residential Product Catalog

Size: px
Start display at page:

Download "GeoFurnace GEOTHERMAL HEAT PUMPS. July 1, Residential Product Catalog"

Transcription

1 GeoFurnace GEOTHERMAL HEAT PUMPS July 1, 2009 Residential Product Catalog GeoFurnace Mfg. Inc th St. SE De Smet, SD Phone: Fax:

2 Blank 7/22/2009 2

3 Table of Contents Introduction 5 Design Standards 9 Product Information Nomenclature & Legend Dimensional Data - Forced Air 38 Dimensional Data - Water-to-Water 43 Dimensional Data - Combo 45 Dimensional Data - HydroCoil 47 Dimensional Data- Split Unit, Condenser & Evaporator 53 Equipment Specifications Forced Air, Forced Air Special, Combo H 2 0 Water-to-Water, H 2 0 Special 57 HydroCoil 61 Split System 67 Pricing Order Form Forced Air Pricing 75 Forced Air Special Pricing 77 Water-to-Water Pricing 79 Water-to-Water Special Pricing 81 Combination Unit Pricing 83 HydroCoil Pricing 85 Split Unit & Evaporator Pricing 87 Accessories Order Form Flow Centers 93 Multi Zone Flow Center 95 Buffer Tanks & Boiler Buddy s 98 PVC Loop Manifolds & PE Headers 100 Heat Pump Accessories 103 Replacement Parts 104 Warranty

4 Blank 7/22/2009 4

5 Introduction What is a GeoFurnace Heat Pump? The GeoFurnace heat pump is the central component of a highly efficient geothermal heating and cooling system capable of providing year-round environmental conditioning of your home or business. The heat pump system runs entirely on electrical power, the most flexible and available form of energy available today. The GeoFurnace heat pump can produce three to five units of energy for every unit it consumes ( COP ), without producing environmentally harmful emissions. A GeoFurnace heat pump system pumps or moves energy from one location to another. In the winter it pumps heat from the warm earth into your home or business. In the summer it removes the heat from your home or business and pumps it into the much cooler earth. Since it takes less energy to move heat than to create it, geothermal heat pump systems are far more efficient than any type of conventional heating or cooling system. Since geothermal heat pump systems do not use a combustion source or a noisy outdoor unit, they are very quiet and clean compared to conventional heating and cooling systems. Geothermal heat pump systems are the safest and most environmentally friendly HVAC system one can buy. Construction Quality GeoFurnace heat pumps are designed and built for long life, and ease of trouble free service. Cabinets are constructed with stainless steel and high quality fasteners. Easy to remove service panels are constructed with galvanized steel. Rubber mounted scroll compressors and blower motor, and sound deadening insulation within the heat pump cabinet ensure extremely quiet operation. The cupronickel heat exchangers are standard equipment on all models. The coaxial heat exchangers are insulated to reduce energy loss and corrosion. In addition, the insulation keeps the coil from forming condensation in low temperatures. Oversized refrigerant-to-air heat exchangers provide high efficiencies at low face air velocity. GeoFurnace heat pumps are designed and built to perform as specified over a very long service life in the extreme Northern and Southern climates. Economics GeoFurnace geothermal heat pump systems save money in ether heating or cooling mode and will produce domestic hot water when ever there is a need when the system is heating or cooling. GeoFurnace heat pump systems are significantly more energy efficient than most other heating or cooling systems on the market today. It has been documented that Geothermal Heat Pump systems can reduce heating costs by 50% to 70% and reduce your air conditioning costs 20% to 30%. The optional de-super heater can save you even more by providing up to 80% of typical residential domestic hot water needs. 5

6 Introduction GeoFurnace Manufacturing SALES POLICIES United States Orders All orders must be presented by a signed order acknowledgement form (to ensure order accuracy) before GeoFurnace Manufacturing Inc. will proceed. All orders are subject to acceptance by GeoFurnace Manufacturing Inc. No liability shall be incurred by GeoFurnace Manufacturing if manufacture or delivery is prevented or delayed by strikes, fires, delays or carriers or other unavoidable delays beyond its reasonable control, or by inability to obtain materials. Prices quoted supersede all prior price lists and are subject to change without notice. Prices do not include any Federal, Provincial, State and local taxes that may be payable on the manufacture, sale or delivery of the merchandise covered by this product catalog. In cases where we are obliged to collect taxes, the same will be billed to the buyer. Credit Terms All accounts will be given a credit limit and terms of 15 days from invoicing, once a customer has set up an account with GeoFurnace Manufacturing Inc. and credit checks have been performed. Interest at the rate of 2% per month will be charged on all past due accounts. GeoFurnace Manufacturing Inc. reserves the right to place customer accounts on credit hold if a customer reaches or exceeds their credit limit. Customers will automatically be placed on credit hold if open invoices reach or exceed past due. Any further product orders will be shipped on Prepaid basis until overdue balance is paid. Freight Terms Prices quoted herein are F.O.B. GeoFurnace Manufacturing Inc. Shipping weights supplied in the product catalog are approximate, for buyer s convenience only, and are not guaranteed. Please provide your choice of transportation facilities and shipping point. Delivery Delivery to the initial carrier shall constitute delivery to the buyer. The seller s responsibility ceases upon delivery in good order to such carrier, and all merchandise is shipped at the buyer s risk. The buyer is urged to examine all deliveries before signing transportation receipts. If merchandise is visibly damaged, the buyer should insist that written confirmation of the damage be noted on the freight bill by the agent of the carrier. If damage is discovered after unpacking, their carrier should be notified at once so that inspection can be made and the claimed damage substantiated by the carrier. Return Material Policy No material may be returned without prior written authorization from the Company. Material arriving at GeoFurnace Manufacturing Inc. without prior authorization will be refused. New material of current manufacture normally stocked, in saleable condition, in original sealed carton may be returned, freight prepaid, after written authorization has been received. In such cases credit will be allowed, less 15% or $35.00 restocking charge, whichever is greater, provided that the product is received free of shipping or other damage. Goods not received in the original sealed carton will be refused. Customer must request a Return of Goods Authorization request form to be completed prior to issuance of a return of goods number. A Return of Goods Authorization Number will subsequently be issued. Warranty Claims All warranty claims will be subject to inspection for defect(s) in material and workmanship. If necessary it may be required to return items to Geo- Furnace Manufacturing Inc. for final determination. In such cases additional time for processing a claim will be incurred. Manufacturer s warranties generally provide for repair or replacement of components found to be defective. Any advance warranty replacement component will require a bona-fide purchase order which may be subject to credit pending warranty inspection. If the manufacturer elects to repair a deemed defective item, such item will be returned to the customer and no further allowance will be made. Order Confirmation and Price Change Upon placing your order, an Order Acknowledgement is automatically ed/faxed to you. This is to ensure that the following are accurate: -Shipping Address -Unit Cost -Part # and quantities -Ship date -Shipping cost, terms and carrier -Your order number When receiving GeoFurnace Manufacturing Inc. s Order Acknowledgement it is your responsibility to inform GeoFurnace Manufacturing Inc. immediately of any discrepancy. The order will be shipped as described on your confirmation. GeoFurnace Manufacturing Inc. reserves the right to extend the shipping delivery according to the quantity ordered. In that case, the shipping date will be modified and be shown on the Order Acknowledgement. Non-Stock Policy Non-stocking units require a signed confirmation form or signed company purchase order (to ensure order accuracy) before GeoFurnace Manufacturing Inc. will proceed. Call for availability of non-stocking units. GeoFurnace Manufacturing Inc. reserves the right to change prices and specifications without notice. 6

7 Introduction Special Notice This manual contains drawings and written material for the sole purpose of providing guidelines for installing GeoFurnace equipment in various configurations on various open and closed loop systems. This manual and the information herein is not to be construed as construction drawings or construction specifications. GeoFurnace shall not be responsible in any way for anything other than providing equipment and materials ordered. Diagrams and schematics shown in this manual may not meet or be in accordance with local, state or federal regulations in effect at time of installation. It is the sole responsibility of the dealer/installer or designer to familiarize themselves with all pertinent regulations and codes. By using guidelines or suggestions of GeoFurnace, be they written, verbal or published the dealer/installer agrees to defend and hold harmless GeoFurnace, it s employees or it s designated agents or representatives in any action resulting from the use of said guidelines and/or suggestions. It is the responsibility of the dealer/installer or designer to determine building loads, soil conditions, water quality and other relevant factors prior to and in conjunction with selecting the appropriate GeoFurnace products. Accurate determination of these factors is a prerequisite for achieving a successful installation of Geo- Furnace products. GeoFurnace Mfg. designs and builds geothermal heat pumps of all sizes and configurations, in addition to accessories and related equipment. GeoFurnace does not performing the functions of a dealer, contractor, installer, designer or engineer. GeoFurnace is not responsible for the performance or function of systems that are designed by a mechanical engineers, contractors, installers, designers or dealers. 7

8 Blank 7/22/2009 8

9 Design Standards

10 Blank 7/22/

11 Design Standards The GeoFurnace heat pump is an extended range, earth coupled energy extraction system that provides heating and cooling as well as domestic hot water heating. Engineering and quality controls are built into every GeoFurnace heat pump, so expected performance depends on proper application and correct installation. Open Loop Systems: are installed using a water well as the energy source to inject or extract heat from the water. Once the water passes through the GeoFurnace, the water is discharged from the system. The water well pump is used to transport the fluid from the well through the GeoFurnace. A solenoid valve controls the water demand while a flow controller controls the volume of water through the GeoFurnace. Closed Loop Systems: are installed in a horizontal or vertical configuration, or submerged in a pond or lake. The closed loop system consists of an underground heat exchanger constructed from high quality polyethylene or pex type A pipe. Pond or lake loops can be constructed of either stainless steel constructed heat exchangers or polyethylene. Horizontal Loops: are often considered when adequate land area is available. There are two types of Horizontal earth loop options when adequate ground moisture is available. A slinky pipe configuration of 800 feet of pipe is placed in an excavated trench, three feet wide, a minimum depth of eight feet, and minimum length of one hundred fifty feet for northern climates. When ground moisture is questioned, a configuration using 800 feet of pipe is placed in a single trench of four hundred feet in length at a minimum depth of eight feet, and a minimum width of six inches. One length of pipe and trench is required for each nominal ton of heat pump. Trenches must be spaced ten to twenty feet apart. (length and spacing of loops do depend on local soil conditions). Vertical Loops: are used if land surface is limited. Drilling equipment is used to bore 3 to 6 holes at depths of 175 feet to 275 feet per nominal ton of heat pump. Two or four high density polyethylene pipes, joined together with a U-bend fitting are inserted in the vertical bore hole. This is standard practice for residential installation. For commercial installation, to conserve on drilling costs and maximize loop field performance, a conductivity test is suggested for loop field design. Bore holes must be spaced 10 to 20 feet apart. Pond or Lake Loops: are very economical to install when a body of water is available. Stainless steel plate exchangers, coils of copper, or polyethylene pipe are placed on the bottom of pond or lake. From the popularity of pond and lake loops, the Slim Jim has become a favorite. The Slim Jim is a stainless steel heat exchanger that is ready to use. In most cases 1/4 to 1/2 acre of water surface, with a minimum depth of 8 feet is required per ton of heat pump. Dealer/Installer Requirements: Dealers and installers are responsible for the technical competence and qualification of their installers, and service technicians. All dealers, installers, and service technicians are required to attend a GeoFurnace training program before installing GeoFurnace equipment. It is strongly suggested that GeoFurnace dealers, installers, and technicians become an accredited International Ground Source Heat Pump Association (IGSHPA) installer, to provide competency in the geothermal industry. Other training or experience may be approved by, and accepted by GeoFurnace Manufacturing at their discretion. In any case, the dealer, installer, or technician shall be responsible for the qualifications of themselves and any employees or subcontractors involved in the installation or service of any GeoFurnace equipment. In addition, it is the sole responsibility of the selling dealer to provide the owner with an Owners Manual and shall make the owner thoroughly familiar with all aspects of the operation and owner responsibility required maintenance, including the importance of filter changing, etc. Dealer shall also fully explain all aspects of the warranty. GeoFurnace Manufacturing, at their discretion, may from time to time require the dealer, installer, and technicians to undergo additional factory training and testing. Equipment Installation: Special care should be taken in locating GeoFurnace equipment. All units should be placed on a vibration absorbing pad, slightly larger than the base of the unit. All units should be placed in an indoor area where ambient temperatures will remain above 45 F and should be located in a way so piping, and ductwork or other permanently installed fixtures do not have to be removed for service and filter replacement. Special Note: All GeoFurnace equipment is designed for indoor installation only. Equipment is not CSA, UL, or ARI certified for outdoor applications. Such installation will void all warranties. 11

12 Design Standards NOTE: Always turn off main power before servicing or removing any panels. CAUTION: Before drilling any screws into cabinet, check that screws will not hit or penetrate internal parts or refrigeration lines. Loop Field Manifold: GeoFurnace recommends the use of a manifold that is located in a vault or the structure being conditioned for all closed earth loop field heat exchangers, in residential applications. Each loop pipe should have its own valve. This practice allows the installing contractor the ability to control all aspects of the installation. Purge the earth loop with the system pump. In addition, it allows technical diagnostics of the earth loop field if an issue may arise. Earth Loop Flow Center: GeoFurnace recommends the installation of a non-pressurized earth loop flow center in the installation of a closed earth loop system. The flow center allows the technician/installer to purge the earth loop pipes individually at any time, when the manifold is in the structure close to the flow center. The flow center must be wired to the heat pump s contactor. A special entrance hole is provided for the thermostat entrance hole. Wire should be connected to the terminals on the compressor side of the contactor. In the application of a combination unit, wire should be connected to labeled terminals (See wiring diagram on electric box cover). Electrical: all wiring, line and low voltage, should comply with the manufacture s recommendations, The National Electric Code, and all local codes and ordinances. Thermostat: make sure that the thermostat is a Geothermal Heat Pump thermostat with a reversing valve energized in the cooling mode. The thermostat should be located and installed according to the manufacture s instructions and recommendations. Thermostats most generally are installed 54 inches off the floor on an inside wall where they are not in the sun at anytime. De-Super Heater Package: The optional de-super heater package provides considerable operating cost savings by utilizing excess heat from the heat pump to help satisfy domestic hot water needs. The de-super heater is active whenever the heat pump is operating in either the heating or cooling mode. A thermostat monitors the incoming water temp, turning the pump off at 128 F. The de-super heater will provide domestic hot water at a very low cost in winter, no cost in the summer. De-super heater output is approximately 900 to 1000 Btu/hr per Nominal Ton of heat pump. De-Super Heater Piping: GeoFurnace recommends 5/8 or 3/4 copper pipe for the first 10 feet from the heat pump s inlet and outlet. Type A PEX pipe can be used from that point on to the water heater. A maximum separation between heat pump and water heater of 50 feet should be observed. All pipes to and from the heat pump should be insulated with 3/8 wall closed cell insulation. On Demand Domestic Hot Water: GeoFurnace offers this option on all heat pumps, and will produce hot water at any time the water heater calls for hot water. The installing contractor is responsible for pump and controls for this system. Electric Auxiliary Heat: allows for cost effective sizing of the heat pump, and provides emergency back-up heating. Electrical service is supplied separately from the main electrical panel. ECM Blower Motor: Electronically Commutated Motors substantially reduces operating cost and provides greater comfort in most applications. The ECM motor will ramp up and down as the restriction of air flow changes. If for any reason, the motor is unplugged, disconnect the power to the heat pump before re-plugging. 12

13 Design Standards The Geothermal heat pump system and the earth loop system shall be one system and include all interconnecting piping and controls to provide an efficient, harmoniously balanced package. Earth Loop: the earth loop field shall be constructed of high-density polyethylene piping. It s layout shall be parallel circuits terminated at a reducing header reverse return design. All underground components shall be fusion welded. The earth loop field shall be designed to provide a minimum of 30 degrees Fahrenheit water/antifreeze mixture to the heat pump during the coldest periods. The antifreeze shall be Propylene Glycol heat transfer fluid mixed 20% by weight with water of 100-PPM grain hardness or less. The piping shall consist of sufficient pump capacity with suction and discharge pressure ports or a flow meter. Air shall be purged from the system. All backfilling and grouting shall be done in accordance with IGSHPA guidelines. Refrigerant Circuit: the compressor shall be a hermetically sealed high efficient scroll, mounted on vibration isolators. The air heat exchanger shall use high-density technology and incorporate enhanced aluminum fins bonded to copper tubing not less than three rows deep. The water heat exchanger shall be a coaxial type; cupro-nickel with enhanced heat exchanger surface. An optional domestic water de-super heater coil of vented double wall copper construction for potable water with a high limit control shall be employed. The expansion device shall be a bi-directional mechanical control. The reversing valve shall be a copper construction with a 24 volt AC solenoid valve with a fail-to-heating position. Cabinet: the heat pump cabinet shall be made from heavy gauge stainless steel with removable galvanized steel panels. It shall incorporate a condensate pan and be installed with 1/2 high-density insulation. It shall be oriented to allow complete component service access from all sides. The electric box shall be of heavy gauge stainless steel located on the access panel side of the cabinet. Controls and Blower Motor: all GeoFurnace units incorporate both high and low pressure switches and freeze protection with total refrigerant circuit lockout with manual reset upon request. The blower motor shall be a high efficient PSC or optional ECM motor with direct driven or belt driven blowers that can be easily removed from the heat pump without duct disconnection. Testing and Warranty: all units shall be tested by and rated in accordance with UL ST 1995 STD. C22.2 NO.236 test laboratory safety and performance standard. Warranties. All heat pumps shall be factory run-tested with ASHRAE test lab standards at simulated design conditions for a minimum of two hours to assure component and system integrity. 13

14 Design Standards Head Loss (ft. of H20) Per 100 of Tubing Pipe ID (in) FLOW RATE GPM HD LS /100 FT ¾ HD LS /100 FT HD LS /100 FT 1-1/ HD LS /100 FT 1-1/ HD LS /100 FT HD LS /100 FT 3.86 HD LS /100 FT Pressure Drop = Head Loss x.4335 Table Calculated Assuming Water at 40 F. Water Volume Per 100 of Pipe Geo-Black Polyethylene Pipe Temperature Limits Geo-Black is recommended for continuous use below 100 F but can be exposed for limited periods to temperature up to 120 F. For design purposes, de-rating pressure factors for higher temperature installations are shown below. Operating Pressure Temperature ( F) Correction Factor Nominal Pipe Size Gallons Liters ¾ SDR-11 1 SDR /4 SDR /2 SDR-11 2 SDR-11 3 SDR-11 4 SDR /4 SCH /2 SCH-40 2 SCH Antifreeze Percentages TYPE Propylene Glycol GS4 Methanol Minimum Temp. for Freeze Protection. 10 F 15 F 20 F 25 F 26% 22% 25% 23% 17% 21% 19% 13% 16% 9% 9% 10% All percentages are by volume (gal/gal), not weight. 14

15 Design Standards Shown below is a typical installation of a water heater connected to a de-super heater package using a concentric fitting. This installation type is used on conventional glass lined water heaters but will not work on all water heaters. The concentric fitting is a tube in a tube configuration and lets the water flow in the water heater in the inner tube and out in the outer tube. When installing the concentric fitting, the water valve at the bottom of the water heater has to be removed and installed in a different location in order to be able to install the concentric fitting. GeoFurnace MA with De-Super Heater Connected to a Metal Water Heater Installation with Concentric Fitting Return Air Supply Air Hot (Out) Cold (In) Flex Connector Flex Connector Water Heater (or Storage Tank) GeoFurnace Neutral Unit Concentric Water Fitting Power Fault Concentric Water Fitting Drain Valve Domestic Hot Water In Domestic Hot Water Out Shut off valves 15

16 Design Standards GeoFurnace MA with De-Super Heater Connected to a Marathon Water Heater Installation R e tu rn A ir C o ld W a te r S u p p ly S u p p ly A ir H o t W a te r S h u to ff V a lv e s F le x C o n n e c to r F le x C o n n e c to r G e o F u rn a c e N e u tra l U n it W a te r H e a te r N o. 1 (o r S to ra g e T a n k ) P o w e r F a u lt D o m e s tic H o t W a te r In D o m e s tic H o t W a te r O u t D ra in V a lv e S h u to ff V a lv e s Additional information on Marathon water heater connection to Heat Pump application can be found at 16

17 Design Standards GeoFurnace MA with De-Super Heater Option Water Heater & Preheat Storage Tank Installation with Concentric Fitting storage tank Return Air Domestic Cold Water Supply Domestic Hot Water Supply Supply Air Hot (Out) Cold (In) Hot (Out) Cold (In) Flex Connector Water Heater (or Storage Tank) Water Heater GeoFurnace Neutral Unit Concentric Water Fitting Power Air Vent Fault Drain Valve Domestic Hot Water In Domestic Hot Water Out Shut off valves 17

18 Design Standards GeoFurnace MA with De-Super Heater Connected to Marathon Preheat Storage Tank and Water Heater Hot Water Cold Water Supply Supply Air Cold Water Supply Hot Water Shutoff Valves Flex Connector GeoFurnace Neutral Unit Water Heater No. 2 (or Storage Tank) Water Heater No. 1 (or Storage Tank) Power Fault Domestic Hot Water In Domestic Hot Water Out Drain Valve Drain Valve Shutoff Valves Additional information on Marathon water heater connection to Heat Pump application can be found at 18

19 Design Standards Piping for Two GeoFurnace MA, Duct Work, GeoFurnace Flow Center, De-Super Heater to Water Heater and Vertical Loop Installation Hot (Out) Cold (In) Water Heater (or Storage Tank) Concentric Water Fitting Concentric Water Fitting Return Air Flex Connector Check Valve Drain Valve Shut off valves Supply Air Return Air Flex Connector GeoFurnace GeoFurnace Loop In Loop Out Power Fault Check Valve Loop In Loop Out Power Fault Supply Air Flex Connector Pt Plugs (Optional) CV CV Flow Center 3/4" loop pipe size parallel configuration. Pt Plugs (Optional) Loop Manifolds Ground Level 160 to 240 feet 12 to 20 feet 19

20 Design Standards GeoFurnace MC, Hot Water Combination, Duct Work, Flow Center, MF Hydronic Fan Coil, SST Storage tank and Vertical Loop Installation Radiant Infloor Zone 1 Heating Hydronic Fan Coil Water in Power Fault Water Out Check Valves are in Pumps SST BUFFER TANK Return Air Supply Air GeoFurnace Power Fault Out (Load Loop) In Loop Out Loop In (load loop) Flow Center Wall Loop Manifolds Ground Level 6 Foot Minimum Recommended 180 to 240 feet 12 to 20 feet 3/4" loop pipe size parallel configuration. 20

21 Design Standards Dual Compressor GeoFurnace MA, Duct Work, Dual Circuit Flow Center with Vertical Shared Loop Installation Return Air Flex Connector Supply Air Return Air Flex Connector GeoFurnace GeoFurnace Power Fault Loop In Loop Out Loop In Loop Out Power Fault Supply Air Flex Connector Pt Plugs (Optional) CV CV Flow Center 3/4" loop pipe size parallel configuration. Pt Plugs (Optional) Loop Manifolds Ground Level 160 to 240 feet 12 to 20 feet 21

22 Design Standards GeoFurnace MW with Flow Center, GeoFurnace Hydronic Fan Coil and SST Buffer Tank 22

23 Design Standards GeoFurnace MW, Dual Compressor, Four Pump Flow Center, GeoFurnace Hydronic Fan Coil and SST Buffer Tank Hydrocoil GeoFurnace Hydrocoil Power Fault Water in SST BUFFER TANK Shutoff Valves GeoFurnace Water to Water DHW out DHW in Loop in #1 Loop #2 in Hydronic #2 in Hydronic #1 in Hydronic #1 out Hydronic #2 out Loop #2 out Loop #1 out Power Fault To Earth Loop Manifold Flow Center Water Out Radiant Infloor Heating Check Valve are in Pumps 23

24 Design Standards GeoFurnace MC, SST Buffer Tank, Pipe Size and Pump Chart, No De-Super Heater Return Air Flex Joint Supply Air Flex Joint Accessible Filter/Rack GeoFurnace 3 1 Power 2 Out (Load Loop) In Loop Out Loop In (load loop) Fault 4 Flow Center HSS BUFFER TANK Shutoff Valves 5 Suggested Pipe & Pumping Sizing Item No. 2 & 3 Ton 4 & 5 Ton 6 Ton Note: Storage tanks must have proper sized ports for adequate flow /4 1 1/ /4 1 1/ /4 1 1/ /4 1 1/4 5 1 Grundfos Grundfos UP Grundfos UP

25 Design Standards Two or more GeoFurnace MW, Pipe Size and Pump Chart Note: Storage tank must have proper sized ports for adequate flow. Suggested Pipe and Pump Sizing Item # Description MW024 thru W036 MW048 thru W072 1 Ground Loop In 1 min 1 1/4 min 2 Ground Loop Out 1 min 1 1/4 min 3 To Loop Manifold 1 1/4 min 2 min 4 Load In 1 min 1 1/4 min 5 Load Out 1 min 1 1/4 min 6 Manifold Piping 1 1/4 min 2 min 7 Load Pump Grundfos UP26-99 Grundfos UP

26 Design Standards GeoFurnace Pipe Size and Pump Chart For MW096 thru MW144 Units, Field Manifold Installation Note: Storage tank must have proper sized ports for adequate flow. Suggested Pipe and Pump Sizing Item # Description W072 thru W096 W120 thru W144 1 Ground Loop In 1 1/4 min 1 1/4 min 2 Ground Loop Out 1 1/2 min 1 1/2 min 3 To Loop Field 3 min 3 min 4 To Manifold 2 min 2 min 5 Load Out 1 1/4 min 1 1/4 min 6 Manifold Piping 2 min 2 min 7 Load Pump Grundfos UP Grundfos UP Flow Center Multizone Multizone 9 Loop Pipe Grundfos UP Grundfos UP

27 Design Standards GeoFurnace MA Neutral Vertical Loop Installation 27

28 Design Standards GeoFurnace MA Neutral Duct Work, Flow Center and Horizontal Loop 28

29 Design Standards GeoFurnace MA Neutral Duct Work, Flow Center and Horizontal Slinky 29

30 Design Standards GeoFurnace MA Neutral Duct Work, Open Loop Well-to-Well System 30

31 Design Standards GeoFurnace MA Neutral Duct Work and Open Loop Well to Dump ( Pump & Dump ) System 31

32 Design Standards GeoFurnace MA Neutral Duct Work, Flow Center, Lake or Pond Loop 32

33 Product Information 7/22/

34 Blank 7/22/

35 Product Information The GeoFurnace MTEX Series Logic Controlled System (ICM222) is a microprocessor-based printed circuit board. It is located in the unit control box for convenient accessibility. This control board is specially designed for the M series units. The board provides control of the unit as well as outputs for status modes, faults and diagnostics. Startup The unit will not operate until all inputs and safety controls are checked for normal conditions. Fault Retry & Diagnostics All faults are retried three times, with 5 minute delay between each attempt, before finally locking the unit out. 1. Blinks for high pressure switch 2. Blinks for low pressure switch 3. Blinks for flow switch Safety Controls The GeoFurnace MTEX Series control receives separate signals for a high pressure switch for safety, a low pressure switch to prevent loss/low refrigerant charge damage & a flow switch for freeze protection. Testing The GeoFurnace MTEX Series control allows service personnel to shorten timing delays for fast diagnostics. If jumper is set to no positions, timing is set to standard, if jumper is set to yes, position timing is reduced for service and startup. Flow Switch (Freeze Protection) Operation When the 24vac is applied to the y terminal, the control board monitors the flow switch input. When the flow switch senses water flow, the control board will energize the compressor contactor, and start the compressor, after the random start is over. If the flow switch is open, at start up, the control board will energize the compressor contactor for a minimum time period of 30 seconds, after 30 seconds, the control board will de-energize the compressor contactor and go into a lockout. The control board will not energize the compressor contactor unless the flow switch closes and the anti-short cycle time has expired. If the flow switch opens three times while the heat pump is operating within 1 hour, the control board will go into lockout and the fault indicator LED will energize. When the flow switch is open, or if in lockout mode, the status LED on the control board will blink three times. Condensation Overflow Protection GeoFurnace MTEX Series units come standard with a condensation sensor. If sensor is sensing condensation liquid the compressor will shut down until the water level reseeds. GeoFurnace MTEX Series Logic Control Board LP1 LP2 Y Test N Y Lockout Board Blinks 1 = HPC P/N: ICM222 2 = LPC 3 = Flow C L R CC Status FS FS HP1 HP2 LP1 Low Pressure HP1 High Pressure LP2 Low Pressure HP2 High Pressure Y H/C Call C Common FS Flow Switch L Fault FS Flow Switch R Power SS Contractor Anti-Short Cycle Operation If all safety controls are satisfactory, the compressor contactor will energize when the control board receives 24vac on the thermostat input y terminal. If the 24vac on the y terminal is removed, the control board will de-energize the compressor contactor and go into a 5 minute lockout. If the 24vac is reapplied to the y terminal again, the control board will not energize the compressor contactor until after the 5 minute lockout is over. High & Low Pressure Safety Operation When the 24vac is applied to the y terminal, the control board is monitoring the high & low pressure switch input to make sure that they are closed. The control board won t start the sequence unless the high & low pressure switch are closed. If the high & low pressure switch opens while the compressor contractor is energized, the control will deenergize the compressor contractor and go into a short lockout. The control board will not energize the compressor contractor unless the high or low pressure switch closes and the anti-short cycle time has expired. If the high or low pressure switch opens three times within 1 hour, the control board will go into manual lockout and the fault contact will energize. When the high or low pressure switch opens or if in lockout mode, the status LED on the control board will blink, one for high and two for low pressure switch. 35

36 Blank

37 Nomenclature 37

38 Vertical Dimensional Data Sheet MA Forced Air Neutral Top Discharge Neutral 2 & 3 Ton Neutral 4, 5 & 6 Ton Model Dimension Data Supply Air Return Air Earth Loop Weight Filter A B C D E F In Out Lbs. MA /2 4 1/2 10 1/4 11 5/8 24 1/4 14 1/ MA /2 4 1/2 10 1/4 11 5/8 24 1/4 14 1/ MA /2 4 1/2 10 1/4 11 5/8 24 1/4 28 1/ MA /2 4 1/2 11 1/ /4 28 1/ MA /2 4 1/2 11 1/ / x x x x30 26 x 30 Note: Down Flow units have the same dimensional data that is inverted. All De-super heaters connections are ¾ FPT. 38

39 Vertical Dimensional Data Sheet MA Forced Air Neutral Pass Through Loop in DMW in DMW out Loop out Condenstion drain Power Fault Loop 1" MPT DMW and Condensation drain 1 2 " MPT Model Dimension Data Bottom Supply Air Top Return Air Earth Loop Weight Filter A B C D E F In Out Lbs. MA / /4 11 5/8 27 1/2 21 1/ MA / /4 11 5/8 27 1/2 21 1/ MA / /4 11 5/8 27 1/2 21 1/ MA / / /2 21 1/ MA / / /2 21 1/ x x x x30 26 x 30 Note: Down Flow units have the same dimensional data that is inverted. All De-super heaters connections are ¾ FPT. 39

40 Horizontal Dimensional Data Sheet Forced Air Vertical End Discharge Horizontal End Discharge Left Hand Side Return Model Dimensional Data Supply Air Return Air Earth Loop Weight Filter A B C D E In Out Lbs. MA /4 31 1/ / /4 11 1/2 24 1/4 14 1/ x 16 MA /4 31 1/ / /4 11 1/2 24 1/4 14 1/ x 16 MA /4 31 1/ / / /4 28 1/ x 30 MA /4 31 1/ / / /4 28 1/ x 30 MA /4 31 1/ / / /4 28 1/ x 30 All De-super heater connections are ¾ FPT. 40

41 Vertical Dimensional Data Sheet MA Forced Air 2 & 3 Ton Neutral Down Flow Side Return Model Dimensional Data Return Air Earth Loop Weight Filter A B C L K M In Out Lbs. MA /2 14 1/2 10 1/2 10 1/2 24 1/4 4 1/ x 16 MA /2 14 1/2 10 1/2 10 1/2 24 1/4 4 1/ x 16 All De-super heater connections are ¾ FPT. 41

42 Vertical Dimensional Data Sheet MA Forced Air Dual Compressor Forced Air Top Discharge Side Return Piping configuration may change, please verify labels on unit each time. Model Dimensional Data Supply Air Return Air Earth Loop Weight Filter A B C D E F G H In Out Lbs. MA072D /2 11 1/ /2 24 1/4 28 1/ x 30 42

43 Dimensional Data Sheet MW H 2 O, Water to Water Single Compressor Piping configuration may change, please verify labels on unit each time. Model Dimensional Data Earth Loop Hydronic Loop Weight A B C D In Out In Out Lbs. MW MW MW MW MW

44 Dimensional Data Sheet MW H 2 O, Water-to-Water Dual Compressor Piping configuration may change, please verify labels on unit each time. Model Dimensional Data Earth Loop Hydronic Loop Weight A B C D E F G In Out In Out Lbs. MW /4 31 1/ /4 2 1/ / MW /4 31 1/ /4 2 1/ / MW /4 31 1/ /4 2 1/ /

45 Vertical Dimensional Data Sheet MC, Combo Vertical Combo 2 & 3 Ton Piping configuration may change, please verify labels on unit each time. Model Dimensional Data Supply Air Return Air Earth Loop MC02 4 A B C D E F G H J In Ou t /2 10 1/4 11 5/ /2 19 1/2 Hydronic Loop In Ou t Weight Lbs. Filter 24 1/4 14 1/ x 16 MC /2 10 1/4 11 5/ /2 19 1/2 24 1/4 14 1/ x 16 45

46 Vertical Dimensional Data Sheet MC Combo Vertical Combo 4, 5, & 6 Ton Piping configuration may change, please verify labels on unit each time. Model Dimensional Data Supply Air Return Air Earth Loop Hydronic Loop Weight Filter MC04 8 MC06 0 MC07 2 A B C D E F G H J In Ou t /2 10 1/4 11 5/ /2 19 1/2 26 1/4 28 1/ x /2 11 1/ /2 19 1/2 26 1/4 28 1/ x /2 11 1/ /2 19 1/2 26 1/4 28 1/ x 30 In Ou t Lbs. 46

47 Dimensional Data Sheet HydroCoil HydroCoil 3 Ton Model Dimensional Data Return Air Earth Loop A B C D E F G H I J K In Ou t MF /2 10 1/4 11 5/8 7 1/2 9 1/2 1 1/ /4 26 1/4 20 1/4 Hydronic Loop In Ou t Weight Lbs. Filter x 22 47

48 Dimensional Data Sheet HydroCoil HydroCoil 5 Ton Model Dimensional Data Return Air Earth Loop A B C D E F G H I J K In Ou t MF /2 11 1/ /2 7 1/2 1 1/ /4 26 1/4 24 1/4 Hydronic Loop In Ou t Weight Lbs. Filter x 26 48

49 Dimensional Data Sheet MS Split Model Dimensional Data Earth Loop Freon Weight A B C D E F In Out In Out Lbs. MS /2 2 1/ /2 7/8 240 MS /2 2 1/ /2 7/8 250 MS /2 2 1/ /2 7/8 260 MS /2 2 1/ /2 7/

50 Dimensional Data Sheet ME Evaporator Evaporator 2, & 3 Ton Model Dimensional Data Return Air Freon Weight Filter A B C D E F G H J In Out In Out Lbs. ME /4 10 1/4 11 5/ /4 14 1/4 1/2 7/ x 16 ME /4 10 1/4 11 5/ /4 14 1/4 1/2 7/ x 16 50

51 Dimensional Data Sheet ME Evaporator Evaporator 4, 5, & 6 Ton Model Dimensional Data Return Air Freon Weight Filter A B C D E F G H J In Out In Out Lbs. ME /2 10 1/4 11 5/8 2 3/4 28 1/2 2 1/2 24 1/4 28 1/4 1/2 7/ x 30 ME /4 10 1/4 11 5/8 2 3/4 28 1/2 2 1/2 24 1/4 28 1/4 1/2 7/ x 30 51

52 Blank 7/22/

53 Specifications MA, Forced Air, Forced Air Special, & Combo

54 Blank 7/22/

55 MA Specifications Forced Air Refrigerant Charge MA Models Model No S 090S 240S Ref. oz Refrigerant Charge MAD Models Model No. 072D 096D MW120D MW144D MW188D MW360D MW480D MW600D Ref. oz each each each each each each each each Electrical Data 60 HZ Power Per Compressor Fan Motor Total Min Circuit Model No. Volts Phase RLA LRA FLA FLA Ampacity MA009S / MA012S / MA018S 208/ MA024S 208/ MA024T 208/ MA036S 208/ MA036T 208/ MA048S 208/ MA048T 208/ MA060S 208/ MA060T 208/ MA072S 208/ MA090S 208/ MA096D 208/ MA120D 208/ MA144D 208/ S= Single Speed Compressor T= Two Speed Compressor D= Dual Compressor 55

56 Blank 7/22/

57 Specifications MW H 2 O, Water to Water, & H 2 O Special

58 Blank 7/22/

59 MW Specifications Water-to to-water Refrigerant Charge MW Models Model No. MW024 MW036 MW048 MW060 MW072S MW090S MW240S Ref. oz Refrigerant Charge MWD Models Model No. MW072D MW096D MW120D MW144D MW188D MW360D MW480D MW600D Ref. oz each each each each each each each each Electrical Data 60 HZ Power Per Compressor Total Min Circuit Max Fuse Model No. Volts Phase RLA LRA FLA Ampacity Size MW024S 208/ MW024T 208/ MW036S 208/ MW036T 208/ MW048S 208/ MW048T 208/ MW060S 208/ MW060T 208/ MW072S 208/ MW090S 208/ MW096D 208/ MW120D 208/ MW144D 208/ MW180D 208/ MW240S 208/ MW360D 208/ MW480D 208/ MW600D 208/ S= Single Speed Compressor T= Two Speed Compressor D= Dual Compressor 59

60 Blank 7/22/

61 Engineering Specifications Hydro Coil

62 Blank 7/22/

63 MF Specifications HydroCoil Special Note The GeoFurnace MTex Series HydroCoil is designed for providing Forced Air heating and cooling from a buffer tank that is maintained by a Water-to-Water heat pump application. The HydroCoil allows more variables and versatility when controlling the environment of a specific area. For cooling ability from a HydroCoil, one must have a reversible Water-to-Water heat pump. The HydroCoil is designed for water temperatures 115 degrees Fahrenheit for heating and 48 degrees Fahrenheit for cooling. One will accomplish proper dehumidification with the HydroCoil at water temperatures of 48 degrees Fahrenheit and below. Please refer to the HydroCoil installation manual for any additional information for proper installation. 63

64 MF Specifications HydroCoil Electrical Data Model No. Fan Motor kw Volts Amps Minimum Maximum Minimum CFM Circuit Circuit MF036 1/2 HP 560 Watts MF060 3/4 HP 860 Watts MF036-3 Ton HydroCoil - CFM 1200 Heating WPD Cooling Coil Specification Model GPM EWT Btu/Hr Ft/Hd EWT Btu/Hr Height Width Rows Fins/In Sq/Ft In/Out ( i n ) ( i n ) ( i n ) MF MF MF MF MF048-4 Ton HydroCoil - CFM 1600 Heating WPD Cooling Coil Specification Model GPM EWT Btu/Hr Ft/Hd EWT Btu/Hr Height Width Rows Fins/In Sq/Ft In/Out ( i n ) ( i n ) ( i n ) MF MF MF MF

65 Manual HydroCoil MF060-5 Ton HydroCoil - CFM 2000 Heating WPD Cooling Coil Specification Model GPM EWT Btu/Hr Ft/Hd EWT Btu/Hr Height Width Rows Fins/In Sq/Ft In/Out ( i n ) ( i n ) ( i n ) MF MF MF MF MF072-6 Ton HydroCoil - CFM 2400 Heating WPD Cooling Coil Specification Model GPM EWT Btu/Hr Ft/Hd EWT Btu/Hr Height Width Rows Fins/In Sq/Ft In/Out ( i n ) ( i n ) ( i n ) MF MF MF MF Hydronic A Coils A Coils to be placed on Gas Furnaces Heating Base Dimension Size GPM EWT Btu/Hr Depth Width CFM In/Out ( in )

66 Blank 7/22/

67 Specifications Split System

68 Blank 7/22/

69 MS Specifications Split Systems Special Note The GeoFurnace MTex Series Split System is a ground coupled heat pump designed for a remote evaporator application. The installing contractor must provide and install a line set between the two units and a bi-directional expansion valve. The Split can be purchased as a complete package including the condenser and evaporator less line set, or the condenser unit separately. When the condenser unit is purchased separately, an A coil is used with an existing fan source. When selecting the correct sizing for an A coil for a split application, one needs to select a size larger than the rated size of the Split Condensing Unit. As a standard feature, the Split comes with a de-super heater. The de-super heater heats domestic water while the heat pump is operating in heating or cooling. This function is designed to remove 900 to 1000 Btu/ hr, per ton of heat pump, of super heated refrigerant directly from the compressor and direct it to the domestic hot water heater needs when there is a call for domestic hot water. The Split comes equipped with a circulating pump and built in thermostat to monitor the call for domestic hot water. Do not use pex pipe for plumbing the de-super heater to the water heater. Please refer to the Split installation manual for any additional information for proper installation. 69

70 Blank

71 Pricing Prices Subject to Change Without Notice

72 Blank 7/22/

73 7/22/

74 MA Forced Air Standard Features: R410A Scroll Compressors Return Air Filter Rack with Filter Insulated Cabinet All Panels Removable for Easy Service Stainless Steel Frame with Galvanized Doors Stainless Steel Condensate Pan ECM Blower Motor High & Low Pressure Protection Water Flow Protection LED Diagnostics Built in Condensate Trap 10 Year Limited Warranty Optional: De-super heater with Integral Circulating Pump Right or Left Hand Air Return Top, Side or Bottom Discharge Single Phase 220 Volt or Three Phase 208, 230, 460 or 575 Volt Built in Resistance Heat Strip 5, 10 or 15 kw Dual Stage Compressor Recommended Accessories: Make-up Heater Base Pad Thermostat Flow Center Manifold Earth Loop Tubing Glycol 74

75 MA Forced Air Pricing Single Stage R410A Model Heating & Cooling Heating Cooling List Price Vertical Horizontal Deduct for No De-super heater Btu/hr * Btu/hr * MA024S11..2CT 19,632 23,590 $6, $6, $320 MA036S11..2CT 27,757 35,916 $8, $8, $320 MA048S11..2CT 40,122 48,996 $9, $9, $320 MA060S11..2CT 52,644 59,941 $10, $10, $320 MA072S11..2CT 61,935 73,912 $12, $12, $320 * Listed capacities at ISO conditions for a Closed Earth Loop System. Dual Compressor R410A Model Heating & Cooling Heating Cooling List Price Vertical Horizontal Deduct for No De-super heater Btu/hr * Btu/hr * MA072D11..2CT 55,514 71,832 $16, $16, $640 MA096D11..2CT 80,244 97,992 $17, $17, $640 MA0120D11..2CT 105, ,882 $20, $20, $640 MA144D11..2CT 123, ,824 $22, $22, $640 * Listed capacities at ISO conditions for a Closed Earth Loop System. Add On Internal Slide in Strip Heat List WT-DM0525H 5 kw Strip Heat $ WT-DM1035H 10kW Strip Heat w/ Breaker $ WT-DM1535H 15kW Strip Heat w/ Breaker $ Voltage Table Add MA***I1 ***1 208/230 VAC, 1 Phase, 60hz NC MA***I2 ***2 208/230 VAC, 3 Phase, 60hz $ MA***I3 ***3 460/480VAC. 3 Phase, 60HZ $ MA***I4 ***4 575 VAC, 3 Phase, 60hz $

76 MA Forced Air Special Features Standard Features: R410A Copeland Two Speed Scroll Compressor Return Air Filter Rack with Filter Insulated Cabinet All Panels Removable for Easy Service Stainless Steel Frame with Galvanized Doors Stainless Steel Condensate Pan ECM Blower Motor High & Low Pressure Protection Water Flow Protection LED Diagnostics Built in Condensate Trap 10 Year Limited Warranty Optional: De-super heater with Integral Circulating Pump Right or Left Hand Air Return Top, Side or Bottom Discharge Single Phase 220 Volt or Three Phase 208, 230, 460 or 575 Volt Built in Resistance Heat Strip 5, 10 or 15 kw Recommended Accessories: Back-up Heater Base Pad Thermostat Flow Center Manifold Earth Loop Tubing Glycol 76

77 MA Forced Air Special Pricing Two Stage R410A Model 1st Stage Heating Heating & Cooling 1st Stage 2nd Stage Cooling Heating Btu/ 2nd Stage Cooling List Price Vertical Horizontal Deduct for NO De-super super-heater Btu/hr * Btu/hr * hr * Btu/hr * MA024T11..2CT 16,518 18,877 25,917 26,165 $9, $9, $320 MA036T11..2CT 20,744 22,323 33,772 37,284 $10, $10, $320 MA048T11..2CT 24,129 26,994 41,103 44,801 $11, $11, $320 MA060T11..2CT 31,974 34,121 52,963 56,665 $12, $12, $320 * Listed capacities at ISO conditions for a Closed Earth Loop System. Add On Internal Slide in Strip Heat List WT-DM0525H 5 kw Strip Heat $ WT-DM1035H 10kW Strip Heat w/ Breaker $ WT-DM1535H 15kW Strip Heat w/ Breaker $ Voltage Table Add MA***I1 ***1 208/230 VAC, 1 Phase, 60hz NC MA***I2 ***2 208/230 VAC, 3 Phase, 60hz $ MA***I3 ***3 460/480VAC. 3 Phase, 60HZ $ MA***I4 ***4 575 VAC, 3 Phase, 60hz $

78 MW H 2 O Water-to-Water Design Features Standard Features: R410A Scroll Compressor Insulated Cabinet All Panels Removable for Easy Service Stainless Steel Frame with Galvanized Doors High & Low Pressure Protection LED Diagnostics Water Flow Protection 10 Year Limited Warranty Optional: De-super heater with Built-In Circulating Pump Single Phase 220 Volt or Three Phase 208, 230, 460 or 575 Volt Single Stage Compressor Dual Stage Compressor Two Speed Compressor On Demand Domestic Hot Water Recommended Accessories: Buffer Tank Base Pad Thermostat Flow Center Manifold Earth Loop Tubing Glycol NOTE: All Water-to-Water units must be installed with a buffer tank of 5 to 8 gallons per nominal size with a recommended minimum of 1 1/4 porting and proper piping. 78

79 MW Water-to-Water Pricing Single Stage R410A Partial Domestic Hot Water Full Time Domestic Hot Water Model Heating Cooling List Price Deduct For No Add For Double Wall Btu/hr * Btu/hr * De-Super Heater Heat Exchanger MW024S11002CT 19,800 26,200 $ $ $1, MW036S11002CT 30,290 35,970 $7, $ $1, MW048S11002CT 40,100 49,000 $8, $ NA MW060S11002CT 52,210 60,340 $9, $ NA MW072S11002CT 64,700 70,910 $9, $ NA * Listed capacities at ISO conditions for a Closed Earth Loop System. Dual Single Stage R410A Partial Domestic Hot Water Full Time Domestic Hot Water Model Heating Cooling List Price Deduct For No Add For Double Wall Btu/hr * Btu/hr * De-Super Heater Heat Exchanger MW072D11002CT 60,580 71,940 $14, $ $1, MW096D11002CT 80,200 98,000 $15, $ NA MW120D11002CT 104, ,680 $17, $ NA MW144D11002CT 129, ,820 $19, $ NA * Listed capacities at ISO conditions for a Closed Earth Loop System. Add On: if substituting double wall Coaxial Heat exchanger for a standard single wall, please add the following. Double Wall Coaxial Heat Exchanger add $1,000. Voltage Table Add MA***I1 ***1 208/230 VAC, 1 Phase, 60hz NC MA***I2 ***2 208/230 VAC, 3 Phase, 60hz $ MA***I3 ***3 460/480VAC. 3 Phase, 60HZ $ MA***I4 ***4 575 VAC, 3 Phase, 60hz $

80 MW Water-to-Water Special Design Features Standard Features: R410A Copeland Ultra Two-Speed Compressor Insulated Cabinet All Panels Removable for Easy Service Stainless Steel Frame with Galvanized Doors High & Low Pressure Protection LED Diagnostics Water Flow Protection 10 Year Limited Warranty Optional: Desuperheater with Integral Circulating Pump Single Phase 220 Volt Single Stage Compressor Dual Stage Compressor On Demand Domestic Hot Water Recommended Accessories: Buffer Tank Base Pad Thermostat Flow Center Manifold Earth Loop Tubing Glycol NOTE: All Water-to-Water units must be installed with a buffer tank of 5 to 8 gallons per nominal size with a recommended minimum of 1 1/4 porting and proper piping. 80

81 MW H 2 O Water-to-Water Special Pricing R410A Partial Domestic Hot Water Full Time Domestic Hot Water Model 1st Stage Heating Btu/hr * 1st Stage Cooling Btu/hr * 2nd Stage Heating Btu/hr * 2nd Stage Cooling Btu/hr * List Price Deduct For No De-Super Heater Add For Double Wall Heat Exchanger Copeland Ultra Tech Dual Stage MW024T1100..CT 16,306 18,400 25,187 26,900 $7, $ $1, MW036T1100..CT 20,553 22,700 33,196 36,200 $9, $ $1, MW048T1100..CT 25,106 29,000 43,310 47,310 $9, $ $1, MW060T1100..CT 33,955 36,560 55,309 60,130 $10, $ $1, Add On: if substituting double wall Coaxial Heat exchanger for a standard single wall, please add the following. Double Wall Coaxial Heat Exchanger $1,

82 MC Combo Design Features Vertical Multi-Function Water-to to-air & Water-to to-water - Optional O n Demand Domestic Hot Water Standard Features: R410A Scroll Compressors Return Air Filter Rack with Filter Insulated Cabinet All Panels Removable for Easy Service Stainless Steel Frame with Galvanized Doors ECM Blower Motor High & Low Pressure Protection LED Diagnostics Water Flow Protection Built in Condensate Trap 10 Year Limited Warranty Optional: Desuperheater with Integral Circulating Pump Right or Left Hand Air Return Top, Side or Bottom Discharge Single Phase 220 Volt or Three Phase 208, 230, 460 or 575 Volt Built in Resistance Heat Strip 5, 10 or 15 kw Single Stage Compressor Dual Stage Compressor On Demand Domestic Hot Water Recommended Accessories: Buffer Tank Back-up Heater Base Pad Thermostat Flow Center Manifold Earth Loop Tubing Glycol NOTE: All Combo units must be installed with a buffer tank of 5 to 8 gallons per nominal size with a recommended minimum of 1 1/4 porting and proper piping. 82

83 MC Combo Pricing Single Stage R410A Model Heating & Cooling Heating Cooling Btu/hr * Btu/hr * Hydronic Heating Output List Price Vertical Horizontal Deduct for NO De-Super Heater MC024S11..2CT 19,632 23,590 19,800 $9, $9, $320 MC036S11..2CT 27,757 35,916 30,290 $10, $10, $320 MC048S11..2CT 40,122 48,996 40,100 $11, $11, $320 MC060S11..2CT 52,644 59,941 52,210 $13, $13, $320 MC072S11..2CT 61,935 73,912 64,700 $14, $14, $320 * Listed capacities at ISO and ISO conditions for a Closed Earth Loop System. Model Two Stage R410A Heating & Cooling 1st Stage 1st Stage Heating Cooling 2nd Stage 2nd Stage Heating Cooling 1st Stage Heating Hydronic 2nd Stage Heating List Price Vertical Horizontal Deduct for NO De-Super Heater Btu/hr * Btu/hr * Btu/hr * Btu/hr * Output Output MC024T11..2CT 16,518 18,877 25,917 26,165 16,306 25,187 $11, $11, $320 MC036T11..2CT 20,744 22,323 33,772 37,284 20,553 33,169 $12, $12, $320 MC048T11..2CT 24,129 26,994 41,103 44,801 25,106 43,310 $12, $12, $320 MC060T11..2CT 31,974 34,121 52,963 56,665 33,955 55,309 $14, $14, $320 * Listed capacities at ISO and ISO conditions for a Closed Earth Loop System. Add On: If substituting double wall Coaxial Heat exchanger for a standard single wall, please add the following. Double Wall Coaxial Heat Exchanger $1,100. Secondary Coaxial Hydronic Heat Exchanger ( double wall ) $2,200. Add On Internal Slide in Strip Heat List WT-DM0525H 5 kw Strip Heat $ WT-DM1035H 10kW Strip Heat w/ Breaker $ WT-DM1535H 15kW Strip Heat w/ Breaker $ Voltage Table Add MA***I1 ***1 208/230 VAC, 1 Phase, 60hz NC MA***I2 ***2 208/230 VAC, 3 Phase, 60hz $ MA***I3 ***3 460/480VAC. 3 Phase, 60HZ $ MA***I4 ***4 575 VAC, 3 Phase, 60hz $

84 MF HydroCoil Design Features Standard Features: Return Air Filter Rack with Filter Insulated Cabinet All Panels Removable for Easy Service ECM Blower Motor Built in Condensate Trap 5 Year Limited Warranty Optional: Right or Left Hand Air Return Top, Side or Bottom Discharge Single Phase 220 Volt Built in Resistance Heat Strip 5, 10 or 15 kw 84

85 MF HydroCoil Pricing Model List Price MF036 $3, MF048 $3, MF060 $3, MF072 $3, Note: MF048 comes in the MF036 Cabinet and MF072 comes in a MF060 Cabinet. MF048 and MF072 can be special ordered with a six week delivery time. Add On Internal Slide in Strip Heat List WT-DM0525H 5 kw Strip Heat $ WT-DM1035H 10kW Strip Heat w/ Breaker $ WT-DM1535H 15kW Strip Heat w/ Breaker $

86 MS Split Design Features Standard Features: Optional: R410A De-super heater with Integral Circulating Pump Scroll Compressors Single Phase 220 Volt or Three Phase 208, Insulated Cabinet 230, 460 or 575 Volt All Panels Removable for Easy Service Single Stage Compressor Stainless Steel Frame with Galvanized Doors Dual Stage Compressor High & Low Pressure Protection Water Flow Protection Recommended Accessories: LED Diagnostics Line Set 10 Year Limited Warranty Base Pad Flow Center MS Split Evaporator Design Features Standard Features: R410A Return Air Filter Rack with Filter Insulated Cabinet Stainless Steel Frame with Galvanized Doors ECM Blower Motor Built in Condensate Trap Optional: Right or Left Hand Air Return Top, Side or Bottom Discharge Single Phase 220 Volt Built in Resistance Heat Strip 5, 10 or 15 kw Single Stage Compressor 86

87 MS Split System Pricing Condensing Unit Only Single Speed Compressor R410A Partial Hot Water Model List Price Deduct for NO De-Super Heater MS024S11000CS $5, $ MS036S11000CS $5, $ MS048S11000CS $6, $ MS060S11000CS $6, $ Two Speed Compressor R410A Partial Hot Water Model List Price Deduct for NO De-Super Heater MS024T11000CS $7, $ MS036T11000CS $7, $ MS048T11000CS $8, $ MS060T11000CS $8, $ Size DX A Coils 1 ton Larger than Condensing Unit Evaporator Unit Only Model List Price ME024N10..2CT $3, ME036N10..2CT $3, ME048N10..2CT $4, ME060N10..2CT $4, Line Set Sizing Refrigerant Connections Model Liquid Suction MS CS 3/8 5/8 MS CS 3/8 3/4 MS CS 3/8 3/4 MS CS 1/2 7/8 87

88 Blank 7/22/

89 Parts & Accessories Prices Subject to Change Without Notice.

90 Blank 7/22/

91

92 Flow Centers Sealable Lid - provides for a non-pressurized system while allowing for ease of access to sample fluid and measure the flow rate. Inlet Connection - 1 1/4 stainless steel. MPT connection provided as standard, with various transition available upon request. Size based on canister size. Check Valves - check valves are provided in each pump circuit assuring proper flow and reliable pump operation. Canister - provides a standing column of water on the suction side of the pump ( s ) to ensure a flooded volute and reliable pump operation. Size required is based on max load design flow rate ( see chart ). Optional Ball Valve - butterfly valve is available as an option to isolate canister from pump manifold. Pump Circuits - individual pump circuits consisting of one, two or three 1/6 hp circulating pumps. Capable of delivering up to ft of H20. Grundfos 116F is standard with others available upon request. For flow rates greater then 25 gpm larger end suction pumps are available. Voltage ph. Pump Isolation - 1 1/4 brass isolation ball valves provided above and below each pump ( or set of pumps) allowing for service of one circulator while the rest of the system is functional. Insulation - 3/8 Armaflex insulation factory installed to prevent condensation. Pump Manifold - factory assembled manifold, including check valves, one isolation valve per circuit and drain valve at the end of the manifold 4 circuits and larger. Pump Connection - 1 1/4 FPT brass with isolation ball valve. Pump Control - pumps can be directly controlled with a branch circuit from the heat pump or controlled with a relay box. Manifold Connection - flange provided to field assemble the pump manifold to the canister and allowing for installation of optional butterfly valve. 92

93 Flow Centers Designed for Non-pressurized Systems Eliminate the Hassles of Air in Pressurized Systems Constructed of Open Cell Insulation with Stainless Steel Tank E-Coated Grundfos Pumps, Brass Ball Valves on both sides of the Pump. Flow Center for One Heat Pump Overall Size ( inches ) Model Description List Price Inlet/Outlet Volts Amps Height Width Depth SST Single Pump $ /4 MPT/FPT SST Double Pumps $ /4 MPT/FPT SST Double Pumps $ /4 MPT/FPT Constructed of Open Cell Insulation with Stainless Steel Tank E-Coated Grundfos Pumps, Brass Ball Valves on both sides of the Pump. Flow Center for Two Heat Pumps Overall Size ( inches ) Model Description List Price Inlet/Outlet Volts Amps Height Width Depth SST Set of ( 2 ) Pumps $ /4 MPT/FPT SST Set of ( 2 ) Pumps $ /4 MPT/FPT SST Sets of ( 2 ) Pumps $ /4 MPT/FPT SST sets of ( 2 ) Pumps $ /4" MPT/FPT Single Flow Center for One or Two Heat Pumps Nomenclature SST Size No. of Heat Pump No. of No. of ( g allon ) Circuits 230 V Pumps 230V Pumps Sample SST

94 Single Heat Pump Flow Centers Dimensional Data A B C D /8 4 11/ /4 94

95 Multi-zone Flow Centers Estimated Dimensional Data Size A B C D E F / /2 27 1/ / /4 Size ( g allon ) Tank Price Heat Pump Circuit V Pump V Pump 6 $ $ $ $ $ $ $ $ Multizone Flow Center Nomenclature SST Size No. of Heat Pump No. of No. of ( g allon ) Circuits 230 V Pumps 230V Pumps Sample SST Note: A 6 gallon buffer tank is only used with up to 2 circuits. 95

96 SST Hydronic Buffer Tanks A Non-Pressurized Stainless Steel Buffer Tank for Hydronic Heat Hydronic Zone Return CUSTOM SIZES MADE Ranco Controller B&G Zone Troll Control Box Hydronic Return to Heat Pump Zone Hook-up Available Sizes: SST /4 or 2 inlet & 3/4 or 1 Ball Valve outlets Water Temp not to exceed 150 degree max. Designed for 6 to 10 gallons per ton of storage. 115V Pump on Hydronic Heat Side & 230V Pump w/ Water Side. Hydronic Pump Relay Standard Sensor for One Stage Heat, Two Stage Heat, or Heating & Cooling built in. For pricing and design please call your distributor or GeoFurnace Manufacturing Inc

97 SST Hydronic Buffer Tank Specifications See next page for Buffer Tank Nomenclature. Thermostat Hook-ups LED Zone Calling Lights Relay Switches 115V Power Supply for Zone Pumps Power Supply for Control Board Buffer Tank Physical Dimensions ( in.) * Gallon Size Manifold Arm Height (A) Tank Body Height (B) Total Tank Height (C) Tank Width (D) Pipe Size (E) Header Outlet Size (F) Tank Weight Lbs /2 1 1/4 IPT 1 1/4 U 60 * Dimensions are approxi- 97

98 SST Buffer Tank Nomenclature GeoFurnace SST Hydronic Buffer Tank Pricing Size Tank Heat Pump 26-99, 230V , 1st Stage 2nd Stage Hydronic Price Circuits Pump 230V Pump Heat Only Heat & Cool Zone 115V Cir. 120V Cir. Aquastat Aquastat Circuits Pump Pump 40 $3, $ $ $ $1, $1, $ $ $ Boiler Buddy Tank Pricing Size Tank Heat Pump 26-99, , 1st Stage 2nd Stage Hydronic Price Circuits 230V Pump 230V Pump Heat Only Heat & Cool Zone 115V Cir. 120V Cir. Aquastat Aquastat Circuits Pump Pump 30 $ $ $ $ $1, $1, $ $ $ $ $ $ $ $1, $1, $ $ $

99 Boiler Buddy 30 Gallon 80 Gallon Model Dimensions Capacity Max Drain Air Weight Pressure Connections Vent A B C D E F G Gallons PSI NH ( M ) NPT Lbs. BB /2 BB /4 65 1/2 54 7/8 14 1/4 8 3/8 3 7/8 66 1/4 55 1/8 23 1/8 8 3/8 3 7/8 1 1/ /4 1/ / /4 1/

100 Loop Manifolds PVC Manifolds Part # INDOOR EARTH LOOP MANIFOLDS - PVC Manifolds Description GeoFurnace List GFM - MI232PA 2 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI232PS 2 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI232PA & PS-INS 2 CIRCUIT 3/4" X 1-1/4" HEADER INSULATED $ per set GFM - MI332PA 3 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI332PS 3 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI332PA & PS-INS 3 CIRCUIT 3/4" X 1-1/4" HEADER INSULATED $ per set GFM - MI432PA 4 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI432PS 4 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI432PA & PS-INS 4 CIRCUIT 3/4" X 1-1/4" HEADER INSULATED $ per set GFM - MI532PA 5 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI532PS 5 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI532PA & PS-INS 5 CIRCUIT 3/4" X 1-1/4" HEADER INSULATED $ per set GFM - MI632PA 6 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI632PS 6 CIRCUIT 3/4" X 1-1/4" HEADER $ per set GFM - MI632PA & PS-INS 6 CIRCUIT 3/4" X 1-1/4" HEADER INSULATED $ per set GFM - MI882PA-INS INS 8 CIRCUIT 3/4" X 2" HEADER INSULATED $ per set GFM - MI882PS-INS INS 8 CIRCUIT 3/4" X 2" HEADER INSULATED $ per set GFM - MI1082PA-INS INS 10 CIRCUIT 3/4" X 2" HEADER INSULATED $ per set GFM - MI1082PS-INS INS 10 CIRCUIT 3/4" X 2" HEADER INSULATED $1, per set GFM - MI1282PA-INS INS 12 CIRCUIT 3/4" X 2" HEADER INSULATED $1, per set GFM - MI1282PS-INS INS 12 CIRCUIT 3/4" X 2" HEADER INSULATED $1, per set HEADER/LOOP MANIFOLD A = Angled 100

101 Loop PE Headers POLYETHYLENE UNDEREGROUND EARTH LOOP HEADERS - PARALLEL Part # Description GeoFurnace List GFM - MP /4" INLET X ( 3 ) 3/4" OUTLETS $35.24 each GFM - MP /4" INLET X ( 4 ) 3/4" OUTLETS $43.46 each GFM - MP /4" INLET X ( 5 ) 3/4" OUTLETS $59.82 each GFM - MP /4" INLET X ( 6 ) 3/4" OUTLETS $76.24 each GFM - MP /4" INLET X ( 7 ) 3/4" OUTLETS $92.60 each GFM - MP /2" INLET X ( 4 ) 3/4" OUTLETS $ each GFM - MP /2" INLET X ( 5 ) 3/4" OUTLETS $ each GFM - MP /2"INLET X ( 6 ) 3/4" OUTLETS $ each GFM - MP /2"INLET X ( 7 ) 3/4" OUTLETS $ each GFM - MP /2"INLET X ( 8 ) 3/4" OUTLETS $ each GFM - MP /2"INLET X ( 3 ) 1" OUTLETS $72.42 each GFM - MP /2"INLET X ( 4 ) 1" OUTLETS $93.54 each GFM - MP /2"INLET X ( 5 ) 1" OUTLETS $ each GFM - MP /2"INLET X ( 6 ) 1" OUTLETS $ each GFM - MP /2"INLET X ( 7 ) 1" OUTLETS $ each GFM - MP " INLET X ( 8 ) 3/4" OUTLETS $ each GFM - MP " INLET X ( 9 ) 3/4" OUTLETS $ each GFM - MP " INLET X ( 10 ) 3/4" OUTLETS $ each GFM - MP " INLET X ( 11 ) 3/4" OUTLETS $ each GFM - MP " INLET X ( 12 ) 3/4" OUTLETS $ each GFM - MP /4" INLET X ( 3 ) 1" OUTLETS $49.08 each GFM - MP /4" INLET X ( 4 ) 1" OUTLETS $68.89 each GFM - MP /4" INLET X ( 5 ) 1" OUTLETS $92.21 each GFM - MP /4" INLET X ( 6 ) 1" OUTLETS $ each GFM - MP /4" INLET X ( 7 ) 1" OUTLETS $ each GFM - MP21-8 2" INLET X ( 8 ) 1" OUTLETS $ each GFM - MP21-9 2" INLET X ( 9 ) 1" OUTLETS $ each GFM - MP " INLET X ( 10 ) 1" OUTLETS $ each 101

102 Loop PE Headers POLYETHYLENE UNDERGROUND EARTH LOOP HEADERS OFFSET ALT-180 DEGREES Part # Description List Price GFM - MO /4" INLET X ( 3 ) 3/4" OUTLETS $35.24 each GFM - MO /4" INLET X ( 4 ) 3/4" OUTLETS $43.46 each GFM - MO /4" INLET X ( 5 ) 3/4" OUTLETS $59.82 each GFM - MO /4" INLET X ( 6 ) 3/4" OUTLETS $76.24 each GFM - MO /4" INLET X ( 7 ) 3/4" OUTLETS $92.60 each GFM - MO " INLET X ( 8 ) 3/4" OUTLETS $ each GFM - MO " INLET X ( 9 ) 3/4" OUTLETS $ each GFM - MO " INLET X ( 10 ) 3/4" OUTLETS $ each GFM - MO " INLET X ( 11 ) 3/4" OUTLETS $ each GFM - MO " INLET X ( 12 ) 3/4" OUTLETS $ each GFM - MO /4" INLET X ( 3 ) 1" OUTLETS $49.08 each GFM - MO /4" INLET X ( 4 ) 1" OUTLETS $68.82 each GFM - MO /4" INLET X ( 5 ) 1" OUTLETS $90.99 each GFM - MO /4" INLET X ( 6 ) 1" OUTLETS $ each GFM - MO /4" INLET X ( 7 ) 1" OUTLETS $ each GFM - MO21-8 2" INLET X ( 8 ) 1" OUTLETS $ each GFM - MO21-9 2" INLET X ( 9 ) 1" OUTLETS $ each GFM - MO " INLET X ( 10 ) 1" OUTLETS $ each 102

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

*20D082-05NN* 20D082-05NN

*20D082-05NN* 20D082-05NN 2506 South Elm Street Greenville, IL 62246 www.enertechgeo.com info@enertechmfg.com HT Models Packaged Water-to-Air Horizontal Heat Pumps Engineering Data and Installation Manual Rev.: 25 May 2012D P/N:

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T62 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-239 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING THE AIR CONDITIONER... 3 INSTALLATION INSTRUCTIONS...

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

HEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps

HEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps HEAT CONTROLLER, INC. ENGINEERING DESIGN GUIDE HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Richard Hiles ClimateMaster

Richard Hiles ClimateMaster Minnesota Geothermal Heat Pump Association 2012 Properly Sizing Ground Source Heat Pump Systems Richard Hiles ClimateMaster Objective Properly Size and Select GSHP System for Low Operating Costs And Proper

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

AFFORDABLE RENEWABLE CLEAN

AFFORDABLE RENEWABLE CLEAN AFFORDABLE RENEWABLE CLEAN P R O D U C T L I N E HE ATING CO O LING HOT WATE R w w w. g e o s t a r - g e o. c o m A F F O R DA B L E R E N E WA B L E CLEAN GEOTHERMAL HEAT PUMPS WHAT IS GEOTHERMAL? Geothermal

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

Installation & Operation Manual Hydronic

Installation & Operation Manual Hydronic Installation & Operation Manual Hydronic Installation & Operation Manual Engineering Specifications GeoSource Hydronic Models RGS-W036 RGS-W120 This Page Intentionally Left Blank Table of Contents I. Key

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Installation and Service Manual

Installation and Service Manual Installation and Service Manual W-Series Liquid to Water Geothermal Heat Pump Two-Stage R410a Model Sizes 25-80 Maritime Geothermal Ltd. P.O. Box 2555 Petitcodiac, NB E4Z 6H4 (506) 756-8135 Email: info@nordicghp.com

More information

3 TON Heating Performance Data TON Cooling Performance Data TON Heating Performance Data TON Cooling Performance Data...

3 TON Heating Performance Data TON Cooling Performance Data TON Heating Performance Data TON Cooling Performance Data... Table of Contents I. Key & Legend... 4 Key to Model Numbers... 4 Legend for Tables... 4 II. Warnings & Cautions... 5 III. General Information... 5 Inspection... 5 Storage 5 Protection... 5 Pre- Installation

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR AQUECOIL HYDRONIC HEATING UNITS GENERAL INFORMATION The AQUECOIL Hydronic Heating Unit is offered in many different capacities and physical configurations in order to match

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

Water to Water Geothermal Heat Pump

Water to Water Geothermal Heat Pump Water to Water Geothermal Heat Pump Installation & Operating Instructions Model: THA/THT-*** Application Geo source closed loop or ground water Hydronic water heat/cool output Air handler, water coil,

More information

Installation and Maintenance Manual TA Series

Installation and Maintenance Manual TA Series Installation and Maintenance Manual TA Series Copyright 2012 Bosch, Inc All rights reserved Table of Contents TA Series 3 Table of Contents Model Nomenclature...3 Initial Inspection...4 General Description...4

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 10 Antifreeze Protection 14 Electrical

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

Specifications and Performance

Specifications and Performance R45C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh The Right Fit for Comfort 2.6 3.5 4.4 5.3 kw Heat

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Combo Geothermal Heat Pump

Combo Geothermal Heat Pump Combo Geothermal Heat Pump Installation & Operating Instructions Model: RU-VE* Application Geo source, loop or ground water fluid Forced air vertical cabinet output Standard left ducting return, easily

More information

Specifications and Performance

Specifications and Performance R35C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh 2.6 3.5 4.4 5.3 kw Heat Pump Nominal Capacities 9,000

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

SWVP - SWHP COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS "SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS Belt Driven Self-Contained Packages Vertical and Horizontal Configuration Size 6-8-10 Ton Capacities Spinnaker Industries Inc. SWHP /

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 6 System Application Options 12 Antifreeze Protection 13 Electrical

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS W-75-HACW-P-1T-** Liquid to Water Geothermal Heat Pump Two-Stage R410a 208/230-1-60 Maritime Geothermal Ltd. P.O. Box 2555 Petitcodiac, NB E4Z 6H4 (506)756-8135 Email: info@nordicghp.com

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

FORCED AIR + HYDRONIC

FORCED AIR + HYDRONIC FORCED AIR + HYDRONIC The WaterFurnace Synergy3D series provides forced air heating & cooling and hydronic heat for radiant floors in one convenient package. It was engineered with leading edge components,

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WT MODELS WATER-TO-WATER HEAT PUMPS REVISION C 20D218-09NN 20D218-09NN Section 1: WT Water-To-Water Unit Model Nomenclature Unit Model Nomenclature... 3 Section 2: Installation

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities R21C Packaged Terminal Air Conditioner (PTAC) The Right Fit for Comfort Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 kw 2.6 3.5 4.4 5.3 Model R21C Specifications and Performance

More information

Geothermal HIGH EFFICIENCY HEATING & COOLING. the logical choice for energy efficient residential heating and cooling

Geothermal HIGH EFFICIENCY HEATING & COOLING. the logical choice for energy efficient residential heating and cooling Geothermal HIGH EFFICIENCY HEATING & COOLING the logical choice for energy efficient residential heating and cooling Geothermal the logical choice for energy efficient residential heating and cooling When

More information

Geothermal Heat Pump Systems

Geothermal Heat Pump Systems Geothermal Heat Pump Systems 1 Earth is a Vast Solar Collector 2 U.S. Underground Temperatures 3 The Earth is a Source of Heat in Winter Outdoor air temperature: 5 F 72 F Geothermal heat pumps transfer

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Antifreeze Protection 14 Electrical

More information

EC SERIES MODEL NOMENCLATURE

EC SERIES MODEL NOMENCLATURE EC SERIES Table of Contents Model Nomenclature...1 Introduction...2 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2 Location...2 Installation...2 Condensate

More information

AP SERIES VOLTAGE DESIGNATION: 1-208/1/60 & 230/1/60 CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW

AP SERIES VOLTAGE DESIGNATION: 1-208/1/60 & 230/1/60 CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW Table of Contents Model Nomenclature...1 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2 Location...2 Installation...2 Condensate Drain...3 Duct System...3

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions 4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents

More information

SPECTRACOOL Air Conditioner

SPECTRACOOL Air Conditioner INSTRUCTION MANUAL SPECTRACOOL Air Conditioner G28 1-Phase Model Protecting Electronics. Exceeding Expectations. Pentair Technical Products 2100 Hoffman Way Anoka, MN 55303 +1-763-323-8200 +1-763-576-3200

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

Reinventing Energy Efficiency

Reinventing Energy Efficiency Commercial WATER2AIR EC LARGE SERIES Reinventing Energy Efficiency www.fhp-mfg.com Environmental stewardship is a core philosophy for FHP Manufacturing from design to production to the reduction in our

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

GS SERIES. Table of Contents CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW

GS SERIES. Table of Contents CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW Table of Contents Model Nomenclature...1 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2 Location...2 Installation...2 Condensate Drain...3 Duct System...3

More information

ES Series. Installation and Maintenance Manual

ES Series. Installation and Maintenance Manual ES Series Installation and Maintenance Manual 8733922027 (2014/01) Table of Contents Model Nomenclature...1 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2

More information

Reinventing Energy Efficiency WARMNESS.

Reinventing Energy Efficiency WARMNESS. Residential WATER2WATER WT SERIES Reinventing Energy Efficiency WARMNESS www.fhp-mfg.com Environmental stewardship is a core philosophy for FHP Manufacturing from design to production to the reduction

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

COMMON WATERSIDE ECONOMIZER APPLICATIONS: APPLICATION MANUAL WATERSIDE ECONOMIZER TABLE OF CONTENTS Safety Approvals...1 Common Waterside Economizer Applications...1 Sequence of Operation (Single)...1 Cooling Mode...2 Heating Mode...2 Sequence

More information

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R22C/H Packaged Terminal Air Conditioner (PTAC) Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 The Right Fit for Comfort kw 2.6 3.5 4.4 5.3 Model R22C Packaged Terminal Heat Pump (PTHP)

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

HYDRO-TEMP. Earth Coupled Heat Pumps HYDRO-TEMP CORPORATION P.O. BOX HWY 67 S POCAHONTAS, AR 72455

HYDRO-TEMP. Earth Coupled Heat Pumps HYDRO-TEMP CORPORATION P.O. BOX HWY 67 S POCAHONTAS, AR 72455 HYDRO-TEMP Earth Coupled Heat Pumps HYDRO-TEMP CORPORATION P.O. BOX 566 3636 HWY 67 S POCAHONTAS, AR 72455 VOICE: 1-800-382-3113 FAX: 1-8-892-8323 EMAIL: info@hydro-temp.com PRINTING THIS CATALOG THIS

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Single and Two-Stage Packaged Geothermal Heat Pump

Single and Two-Stage Packaged Geothermal Heat Pump Single and Two-Stage Packaged Geothermal Heat Pump Installation & Operating Instructions Models: TVA/TVT-*** Application Forced air Geo source installation Equipped for optional AUX EL strip heat (controller

More information

Residential Geothermal Technology. Eco-$mart, Inc. Distributed by: TOLL FREE:(888) FAX:(941)

Residential Geothermal Technology. Eco-$mart, Inc. Distributed by: TOLL FREE:(888) FAX:(941) Residential Geothermal Technology Geothermal Heating and Cooling Distributed by: Eco-$mart, Inc. TOLL FREE:(888)329-2705 FAX:(941)377-9460 info@eco-smart.com www.eco-smart.com 1 Residential Geothermal

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

Heat Pumps COMFORT NEED IT. When You

Heat Pumps COMFORT NEED IT. When You Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

Installation & Operation Manual Forced Air

Installation & Operation Manual Forced Air Installation & Operation Manual Forced Air Installation & Operation Manual Engineering Specifications ECONAR ColdClimate Series Forced Air Models REC-V036 REC-V060 Table of Contents I. Key & Legend...

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N SPECTRACOOL Air Conditioner N17 Model INSTRUCTION MANUAL Rev. G 2015 Pentair Equipment Protection P/N 89117329 89117329 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models FORM NO. A22-188 REV. 3 Supersedes Form No. A22-188 Rev. 2 CONDENSING UNITS JEZ 16 Two- Models Efficiencies up to 17.10 Nominal Sizes 2 to 5 Tons [7.03 kw] to [17.06 kw] Four Models Cooling Capacities

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3

More information

Engineering Specification

Engineering Specification Engineering Specification W-75-HACW-P-1T-** Liquid to Water Geothermal Heat Pump 60 Hz Maritime Geothermal Ltd. P.O. Box 2555, 170 Plantation Road Petitcodiac, NB E4Z 6H4 (506) 756-8135 info@nordicghp.com

More information

INSTALLATION NORTHERN HEAT PUMP. XTERRA SERIES Horizontal and Vertical, Single and Dual Stage Geothermal Heat Pumps: FORCAIR AQUA2 SOURC3 TERRA SERIES

INSTALLATION NORTHERN HEAT PUMP. XTERRA SERIES Horizontal and Vertical, Single and Dual Stage Geothermal Heat Pumps: FORCAIR AQUA2 SOURC3 TERRA SERIES NORTHERN HEAT PUMP TERRA SERIES ENERGY EXTRACTION SYSTEM INSTALLATION And Maintenance Manual XTERRA SERIES Horizontal and Vertical, Single and Dual Stage Geothermal Heat Pumps: FORCAIR AQUA2 SOURC3 TABLE

More information