Zettler Magnetics, Inc. By Anthon Vermaerke
|
|
- Victor McDaniel
- 5 years ago
- Views:
Transcription
1 By Anthon Vermaerke
2 Orange County, CA Sales, Technical Support and Warehousing
3 Xiamen, China Wholly owned manufacturing facility
4 OEM VS. DISTRIBUTION OEM, 48% Distributon, 52% Design registration program
5 BV Series of encapsulated transformers Smaller about 1/5 th smaller Better UL rating UL class 2 vs General Purpose Neatly Packaged Open frame vs lamination with varnish Competitively priced About 10% less
6 BV Series of encapsulated transformers Ideal for power requirements under 5VA Input 115VAC or 230VAC 50/60Hz Stepping down to 6VAC - 24VAC + dual output options
7 BV Series of encapsulated transformers Existing Applications Electrical smart meters Deep fryers, Refrigeration, Ovens, Coffee Machine. Motorized window blinds Welding equipment LED Lighting ballast Hot tub controls Oxygen Concentrator Test meters Washing Machines Built in vacuumed systems Burglar Alarm systems Medical
8 Ferrite Switching Transformers Also called Flyback or switch mode transformers High Frequency AC DC Wide input range Nearly always custom Easy to sample and quote (IC Manufactures offer design software)
9 Ferrite Switching Transformers
10 BP & ZP series of AC-DC Power Modules 1W, 3W, 5W &10W power options Plug n Play power solution Cost Effective Resale about $2 per watt Universal input voltage VAC 50/60Hz Output Range 3.3V-24VDC Compact Safety Agency Approved
11 BP & ZP series of AC-DC Power Modules BP series specifically aimed at companies that are part of the EnOcean Alliance which aims to formalize a wireless standard for residential & commercial lighting and HVAC controls. Pin out is a drop in replacement to Bias.
12 BP & ZP series of AC-DC Power Modules Existing Applications LED lighting Consumer electronics Smart thermostats Relay boards Energy harvesting applications Cooking controls Industry control board Electric meters Small motor Controls Test and measurement equipment Central vacuum control
13 AHI Series open frame power Transformers 115/230V input 2.5VA, 5VA & 10VA power ratings UL Class 2 recognized Drop in replacement for: Triad / Tamura / Pulse / MCI / Renco / Prem Existing Applications Deep fryers, Refrigeration, Ovens, Coffee Machine. Defrosting equipment Pool and Spa controls Soda Fountains Elevator controls Gas & Oil Burners
14 AH & ADH & AHF Series open frame power Transformers 115 or 115/230V input 1.1VA - 20VA in 5 power ratings Drop in replacement for: Triad / Tamura / Pulse / MCI / Renco / Prem / Vishay Existing Applications Temperature Controls Garage Door Controls Thermostats Coffee Machines Elevator controls
15 ACST Series Current Sense Transformers and Chokes PCB mountable current sense Turns ration 1:50 up to :1500 Zettler can also build tombstone and toroidal transformers Existing Applications Surge suppression device Power supplies Electrical control box shut off Motor speed control
16 AHR / AHRV Series Chassis-mounted Transformers 20VA-100VA power options 120V to 575VAC Input options UL Class 2 recognized Customizable termination: Wire leads, Quick-Connect terminals or a combination Existing Applications Pool & Spa Pumps Lighting Ovens HVAC Tankless water heaters Fire place starters Garage door openers
17 Key transformer questions when crossing an existing part: Current manufacturer's name and p/n, OR spec. OR samples (qty. 2-3 is ideal) EAU Target price Knowing why the customer is asking for a cross helps quantify the opportunity.
18 Key Questions For A New Transformer Design Input voltage. Output Voltage. Output Current. Power (calculate by multiplying output voltage by current) Mounting method (PCB through hole pins OR chassis mount) Termination (PCB through hole pins OR wire leads OR quick connect terminals) Safety agency requirements the transformer must meet? EAU Target Price Customers estimated time frame for testing and approval.
19 AMXC-479 Inductor Surge protection in street and parking lot lighting AMXC /240V 24V 1VA Smoke Alarm AHI /230-10V 10VA Soda dispenser / Industrial Microwave / Deep fryer
20 AH V-16V 1.1VA Bathroom lighting ADH /230-10V 2.4VA AC cycling switch AMXC-296B 50Amp current sense Ground fault circuit interrupter (GFCI)
21 CM09M HVAC control board for hotel air-conditioning systems.
22 Zettlermagnetics.com
23 Thank You
Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK
Installation Manual AQM-20 12vdc/24vdc Series Power Supplies AQM20 Supervised Power Supply/Charger 12vdc 20Amp/24vdc 10Amp Life Time Warranty Quality Manufactured in the USA AQM20 Features: The AQM20 has
More informationControl Panel Checklist
Control Panel Checklist Versatronik -C Panel Checklist Option Selection for Control Panel Quotes Checklist Control Panel Checklist Section 1 General Information Customer name Phone number Fax number Email
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More informationENERGY COSTS GUIDE FOR COMMON HOUSEHOLD APPLIANCES ENERGY SMART
ENERGY COSTS GUIDE FOR COMMON HOUSEHOLD APPLIANCES ENERGY SMART Tampa Electric is committed to helping you use energy wisely. We developed this brochure to provide you with an approximate cost to run various
More information10606 Bloomfield Ave Santa Fe Springs, CA USA
IAS Accreditation Number FEB-103 Company Name eti Conformity Services Address 10606 Bloomfield Ave Santa Fe Springs, CA 90670 USA Contact Name Sam Daye Telephone (562) 236-9555 Effective Date of Scope
More informationModels NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117
Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring
More informationI/O ZONE 560/583 AND OPERATION MANUAL
UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in
More informationGeneral Information. FAST-STAT wiring extenders electronically add more wires to a control cable.
General Information FAST-STAT wiring extenders electronically add more wires to a control cable. Saves significant time and expense as compared to repulling of new cables. Causes no damage to walls or
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationFireNET Plus Wiring Instructions
FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationFOR SERVICE TECHNICIAN S USE ONLY
F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform
More informationElectricity in your home
Electricity in your home Circuits An electrical circuit is a path between two points in which an electrical current flows. Our homes are filled with circuits of varying size and complexity. 2 Your home
More informationPower Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses
BCU Power Supplies Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses Installation, Commissioning and Operating Manual BCU RANGE OF
More informationData driven insights from the nation s deepest ever customer energy research
Pecan Street Research Institute Pike Powers Lab and Center for Commercialization Data driven insights from the nation s deepest ever customer energy research Change in peak load 70,000 by customer class
More informationResidential 2 Zone Control Panel
Zoning Systems 140202 Residential 2 Zone Control Panel 2 Heat / 1 Cool Compact Housing - 6 x 6 Works with Conventional 4 or 5 Wire Thermostats Works with BlueLink TM Wireless Technology* Installs on Conventional,
More informationModel 4880 Status Output Display Module Manual
Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical
More informationH o m e G e n e r a t o r S y s t e m s
WATTAGE WORKSHEET When selecting a Home Generator System, you need to calculate both your watts and starting wattage requirements. Watts, or running wattage, is the amount of electricity necessary to run
More informationCutting Edge Compressor Technology
CHILLER MODULES Cutting Edge Compressor Technology MagLev ; magnetic levitation Oil Free design Quieter than typical background noise Soft start; pulls only 2 amps at 460V Superior part load efficiency
More informationAC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL
AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL October 2003 Revision A Copyright October 2003 VERSITRON, Inc 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com
More informationMS4525DO SPECIFICATIONS FEATURES APPLICATIONS
FEATURES PSI Pressure Ranges PCB Mountable Digital Output Barbed Pressure Ports APPLICATIONS Blocked Filter Detection Altitude and Airspeed Measurements Medical Instruments Fire Suppression System Panel
More informationPOWER VENTER. Model: PVE Series
POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power
More informationInstallation Guide IM 1248
Installation Guide IM 1248 BACnet Thermostat for Heat Pump Units Group: Controls Part Number: IM 1248 Date: August 2015 Table of Contents Installation Guide Heat Pump.... 2 Applicable Models... 2 Mounting
More informationPVE SERIES POWER VENTER SYSTEM MANUAL
PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of
More informationModel 60200FR Gas Primary Control Data Sheet
Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault
More information30.45 Electric Release PDRP-2001
The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)
R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationQuest Dry 105, 155, and 205 Dual
Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More informationTRACENET TM TCM18 CONTROL AND MONITORING SYSTEM
TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationDocking Drawer. ETL Listed in-drawer electrical outlets. a division of JTech Solutions. Rev
Docking Drawer a division of JTech Solutions ETL Listed in-drawer electrical outlets Rev 100114 About JTech Solutions 15+ year old engineering company servicing the semiconductor industry Expertise in
More informationElectric Coils. Blower Coils. Product Information
Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower
More informationPower Supply Display Module PSDM. Installation and Operation Manual
Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious
More informationA WORD ABOUT PORTABLE ELECTRIC GENERATORS
A WORD ABOUT PORTABLE ELECTRIC GENERATORS Portable fuel-burning generators may be used to supply electricity for the operation of small electrical appliances in the event of a power outage. The most common
More informationUnit 3 Machine Composition
Unit 3 Machine Composition Unit Objectives Given a realistic scenario in which the learner has access to the machine s internal components the learner will understand the composition and functions of the
More informationTECHNICAL DATA OBSOLETE
Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationModel 17A00 Expansion Enclosure
HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number
More informationField Application of Advanced Residential Air Conditioning Systems
Field Application of Advanced Residential Air Conditioning Systems Presented By Greg Spencer, Residential Cooling Service Coordinator with Lennox Industries 1 How Ratings Are Established Size of Indoor
More informationThe TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel
12 Clintonville Road Northford, CT. 06472 (203) 484-7161 FAX:(203) 484-7118 The TC-4F Time Control Module For the Sensican 2000 Fire Alarm Control Panel Document # 15972 3/27/95 Revision C P/N 15972:C
More informationIntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide
IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.
More informationPlug-in Base, Long Range Sensor E3B2
Plug-in Base, Long Range Sensor Plug-in Terminal for Easy Maintenance and Installation Universal AC/DC supply voltage Replace sensing head without rewiring Detect shiny objects with polarized retroreflective
More information200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION
GENERAL DESCRIPTION This product is the photo/thermal/ir variant of 2 Series Advanced, the redesigned 2 Series all SMD adopting the new chamber and a new style of covers. It works with the 2 Series extended
More informationMAGNASPHERE L2 HSS Technology
MAGNASPHERE has Created the L2 Series HSS High Security Sensor The Next Generation Sensors That Meet UL 634 Level 2 High Security Standards for IFs, Safes and Vaults and All Other High Level Secure Applications.
More informationAE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors
October 2017 1.5 to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury
More informationRL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.
Page 1 of 8 RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE
More informationABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE
ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that
More informationMake Ready Estimate. Total Tenant Charges $0
Tenant Charges Interior clean flat rate 0 $0 Pricing: $165-$275 Clean carpets flat rate 0 $0 Replace smoke alarm batteries $7 each 0 $0 Replace light bulbs $8 bulb 0 $0 Replace blinds $35 each 0 $0 Trash
More informationMax Load. Max. Load. Red (+) Black (-) Gray Violet. Part number: CV 96 24DC. Solidrive constant voltage 0-10V dimmable LED driver
MAGNITUDE SOLIDRIVE CONSTANT VOLTAGE 0-V DIMMABLE LED DRIVER E465183 CLASS P CLASS 2 IP65 DIMMABLE 120-277V 96W MAX 24V DC P/N: CVD96x24DC W/ JBOX QUICK SPECS W/O JBOX The SoliDrive Series of Constant
More informationElement D Services Electrical
PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.
More informationDS7400Xi Addressable Control/ Communicator
DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems
More informationAppendix A Equipment Used to Monitor Hotels
Appendix A Equipment Used to Monitor Hotels This Appendix describes the data-acquisition equipment that was used in the monitoring phase of the project. Monitoring equipment was used for: Fan-coil and
More informationwww.greenelectricalsupply.com MAGNITUDE LIGHTING SOLIDRIVE CONSTANT VOLTAGE 0-V DIMMABLE LED DRIVER E465183 CLASS P CLASS 2 IP65 DIMMABLE 120-277V 50W MAX 12V DC P/N: CVD50x12DC W/ JBOX QUICK SPECS W/O
More informationFire and burn safety at home
Fire and burn safety at home Safe signals in the home Kitchen safety Bathroom safety Bedroom safety Living area safety Storage or utility safety Smoke and carbon monoxide detectors Doors and windows Fire
More informationM5200 Industrial Pressure Transducer
SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound
More informationMEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors
MEMS Accelerometer ICs AMR Magnetic Sensor ICs Gas Flow Modules Differential Pressure Sensors Tilt Modules Current Sensors MEMSIC s unique thermal technology uses heated gas molecules to detect acceleration
More informationFOR SERVICE TECHNICIAN S USE ONLY
FOR SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform
More informationDIY Smart Home & Energy Save
2011 Catalog Going green DIY Smart Home & Energy Save www.ekonsense.com Simply Smart E K O N Manufacturing Inc. Global Excellence in Affordable Control Systems EKON Manufacturing Inc. is one of the world's
More informationEcoView Energy Management System
EcoView Energy Management System EcoView Energy Management System What is it? Energy Management Systems (EMS) reduce energy usage and save money by improving the efficiency of a facilities highest-energydemand
More informationQuick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features
Installation Instructions E14QRG Issue Date June 28, 2018 Quick Reference Guide The Direct Spark Gas Ignition control module is designed for direct burner ignition and supervision. It can be used in new
More informationSEALED ENCLOSURE COOLING
ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING ABOVE-AMBIENT AND SUB-AMBIENT COOLING PRODUCTS TABLE OF CONTENTS HEAT SINK COOLER (ACT-HSC) HEAT EXCHANGER
More informationQuest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest Dry 150 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationDS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel
DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed
More informationCONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES
CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES 1 Hair Dryers 8516.31 MS IEC 60335-2-23 Household and similar electrical appliances-
More informationMacurco CM-21A Carbon Monoxide
Macurco CM-21A Carbon Monoxide Detector and Controller User Instructions for 3M Macurco CM-21A - Low voltage, dual relay Carbon Monoxide (CO) detector and controller Important: Keep these User Instructions
More informationILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING
ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING THE ILLUMINATOR ILLUMINATOR SERIES IE The Illuminator Series IE is an interruptible lighting inverter. It transfers to inverter mode (battery
More informationONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)
Cheboygan County Department of Building Safety 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 TX: (231) 627-8813 FX: (231) 627-8454 www.cheboygancounty.net Service Entrance ONE- AND TWO-FAMILY
More informationUDC100 Universal Digital Controller Specifications
UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationA. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.
DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets
More informationIGD.CO.UK
APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2016-01-22 Page 1 of 9 Report Reference # E182560-V4-S48 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1
More informationSINGAPORE I. RATIONALE FOR REGULATION. COUNTRY RATIONALE FOR REGULATION Singapore Consumer Protection II. REGULATION BODY
As of June 2016 SINGAPORE I. RATIONALE FOR REGULATION COUNTRY RATIONALE FOR REGULATION Singapore Consumer Protection II. REGULATION BODY COUNTRY REGULATORY BODY Singapore SPRING Singapore III. LEGISLATIVE
More informationKIT IOM
8733 800-259 KIT IOM Replacement Kit: 641-176 641-187 641-225 641-244 1 Table of Contents THE UPM CONTROLLER...3 SPECIFICATIONS...4 KIT INCLUDES...5 INSTALLATION PROCEDURE...5 Remove Old Board...5 Mounting
More informationOEM Sensors for HVAC manufacturers Pool water
OEM Sensors for HVAC manufacturers Pool water 2 Pool water Typical flow switch application Product features Pump monitoring For pool heaters or water disinfection Protection against overheating, dry-running
More informationGROUND FAULT PROTECTION METHODS & 2017 National Electric Code
GROUND FAULT PROTECTION METHODS 2014 & 2017 National Electric Code Ground Fault Protection Methods A Ground Fault Circuit Interrupter, or GFCI, is a device that functions to de-energize a circuit when
More informationCOMMERCIAL Washington Incentives
COMMERCIAL Washington Incentives MAKE IT YOUR BUSINESS TO SAVE. BRING US IN. COMMERCIAL GAS STANDARD INCENTIVES FOR BUSINESS CUSTOMERS OF NW NATURAL IN WASHINGTON EFFECTIVE JANUARY 2019 ENERGY TRUST OF
More informationHow To Apartment Guide
How To Apartment Guide 2011-2012 Dishwasher Open door. Rinse excess food off dishes in the sink. Fill with dirty dishes. Add dishwasher detergent (not dish soap that you use in the sink). Be sure to fill
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect
More informationSECTION LIGHTING CONTROLS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationBE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.
BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B,
More informationMechanical Systems Submittal Guide
5200 Dover Center Road 440-777-8000 North Olmsted, OH 44070 North-Olmsted.com Mechanical Systems Submittal Guide Residential Code of Ohio (RCO) n applicant is free to submit any mechanical systems description
More informationMAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216
16-128 Zone Control Panel PC4020 16 zones on main control panel supports up to 16 hardwired keypads Expandable up to 128 zones using hardwire, wireless modules and addressable zones COMBUS hardwired expansion
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge
More informationQuest 105, Dry155, and 205 Dual
Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More information24 VAC Direct Spark Gas Ignition
Installation Instructions Issue Date March 3, 2017 Quick Reference Guide The Direct Spark Gas Ignition control module is designed for direct burner ignition and supervision. It can be used in new applications
More informationSERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-703 120 VAC Microprocessor-Based Intermittent Pilot Ignition Control F-35-703 July 2016 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationBionics Instrument. Alarm Handling. Gas Alarm Systems
Gas Alarm Systems Controllers and PLC based systems Alarm Handling Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak,
More informationInstructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s
Instructions Rear (size reduced) Easy-wire terminal strip Microprocessor-operated Front (Processor coordinates operation and diagnostic) Easy remote sense (Electronic sensor, wired to control) Self-checking
More informationTRACENET TM TCM18 CONTROL AND MONITORING SYSTEM
TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to
More informationSINGAPORE I. RATIONALE FOR REGULATION. COUNTRY RATIONALE FOR REGULATION Singapore Consumer Protection II. REGULATION BODY
As of October 2017 SINGAPORE I. RATIONALE FOR REGULATION COUNTRY RATIONALE FOR REGULATION Singapore Consumer Protection II. REGULATION BODY COUNTRY REGULATORY BODY Singapore SPRING Singapore III. LEGISLATIVE
More informationFor more information on the MARR program or any questions on the product list, please refer to or contact MARR at
Major Appliance Recycling Roundtable Updated Major Appliance Recycling Roundtable - and s Background: The following document provides a detailed list of products and relevant definitions captured by the
More informationconfigurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of
SLATE Integrated Combustion Equipment Management The revolutionary integration of configurable safety and programmable logic in a single, modular platform Complexity. This is today. Individual components
More informationFOR SERVICE TECHNICIAN S USE ONLY
F SERVICE TECHICIA S USE OY TE: This sheet contains important Technical Service Data. Tech Sheet Do ot Remove Or Destroy DAGER Electrical Shock Hazard Only authorized technicians should perform diagnostic
More informationProduct No. PLMBZ209GCA Market North America Color stainless steel Volts 120 Watts 1200 Wiring Diagram Owner's Guide TINSEB477MRR0
Product No. PLMBZ209GCA Market North America Color stainless steel Volts 120 Watts 1200 Wiring Diagram 5995500872 Owner's Guide TINSEB477MRR0 GLMB209D.tif PLMBZ209GCA Cabinet.eps GLMB209DSC Door.eps GLMB209DSC
More informationEM4 APPLICATIONS EXAMPLES
2017 EM4 APPLICATIONS EXAMPLES Markets Building Systems Access control, parking barrier, door & window control, HVAC, air filtration, lighting, building automation, road & water infrastructures Industrial
More informationWhy Cooltron Fans & Heat Sinks? By Steven Chiang
Why Cooltron Fans & Heat Sinks? By Steven Chiang 1 Table of Contents -Cooltron Worldwide Business Partners -Cooltron Company Profile -Cooltron Focused Fan & Blower Application Markets -Why Cooltron Fan?
More informationCAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING
Amana Technical Information³Refrigerator P1303511W Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. Refer
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationEnvironmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current
LED Optimized Drivers 6 Watt Series Model: Series Environmental 6W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive
More informationPSN-1000 & PSN 1000(E) Installation Manual
PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com
More information