Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE MODEL DFRC-0400-E SERIAL Nº: /07

Size: px
Start display at page:

Download "Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE MODEL DFRC-0400-E SERIAL Nº: /07"

Transcription

1 Air Humidity Control Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE MODEL DFRC-0400-E SERIAL Nº: /07 According to the current European Union Rules on Machinery Safety, the reading of these instructions is Imperative before installing the unit. FISAIR, S.L. Uranio,20 - P.I. AIMAYR San Martin de la Vega MADRID (SPAIN) DISTRIBUTOR : info@fisair.com

2 INDEX. Introduction...2. Operating instructions Typographic distinctions Safety notes General Operational safety notes Transport General Packing Interim storage Check for complete and correct delivery of goods General description Background The desiccant wheel. Operating principle Dehumidif ier main com ponents identification Options and ancillary components Regulation and control Installation Locating the unit Service areas Air duct connections Electric mains connections Thermal f luids connections Control equipment locations and connections Start up Unit start up Stopping the unit Electrical safety components Maintenance Preventative maintenance Correctiv e maintenance Desiccant wheel service Fault finding General technical data sheet Overall dimensions... 3 Addenda A Delivered unit specification and ancillary components (when applicable). B Overall Dimensions. C Wiring diagram. D Spare parts list. E Fan operating curv es. F Non electrical reactiv ation heater installation scheme (when applicable). G PRE- or POST- cooling coil technical data (when applicable). H Filters certifications (when applicable). F Technical Data Subject to alterations

3 . Introduction Dear customer, The FISAIR dehumidifier is our answer to today's technical requirements. It satisfies them by means of its operational safety, its operational comfort and its economic efficiency. To be sure of operating your FISAIR Dehumidifier efficiently please read these Operation and Maintenance Instructions. Use the steam humidifier only in proper and safe conditions, paying attention to all notes in these instructions. If you have any questions...please contact us: Fisair S.L. Tel.: (34) Fax: (34) Or your local dealer. Operating instructions The correct use of the steam humidifier also includes adherence to our installation, dismantling, refitting, commissioning, operation and maintenance instruction as well as taking correct disposal steps. Only qualified and authorised personnel may operate the unit. Persons transporting or working on the unit, must have read and understood the corresponding parts of the Operation and Maintenance Instruction and especially the chapter Safety Notes. Additionally, operating personnel must be informed of any possible dangers. You should place a copy of the Operation and Maintenance Instruction at the unit's operational location (or near the unit)..2 Typographic distinctions Enumeration with preceding heading: General enumeration.» Enumeration with preceding double chevron: Work or maintenance steps that must be folllowed sequentially. Sequential step to be checked. 2. Safety notes 2. General These safety notes are required by law. They are for your protection and to prevent accidents. Warning notes and safety symbols: The following safety symbols shown in the text will warn about dangers and danger sources. Get familiar with these symbols. Attention: Not observing this warning can lead to injury or danger to your life and/or damage to the unit. Attention,Voltage: Dangerous electrical current. Not observing this warning can lead to injury or danger to your life. Note: Materials/operational equipment; must be handled and/or disposed of according to the law. Note: Further explanation or cross-references to other sections of the text in the Operation and Maintenance Instructions. 2.2 Operational safety notes. In general: Observe all safety and warning notices. If there should be malfunctions, shut down the unit immediately and secure against being restarted. Faults should be rectified immediately. During repair work, guarantee operational safety of the unit by using qualified personnel. Only use original FISAIR spare-parts. For the effective operation of this unit refer to any national regulations restricting or governing its use. Accident prevention regulations Observe the accident prevention regulations: "Electrical Installation and Electrical Equipment" or equivalent national codes. In this way you can prevent injury to yourself or others. F Technical Data Subject to alterations

4 Operation of the unit. 3.3 Interim storage. Do not impair the safety of the unit. Periodically check all protection and warning devices for proper functioning. Safety equipment is not to be removed or put out of operation. Installation, dismantling, maintenance and repair of the Unit. Turn off power, when doing maintenance work or repairs to the unit. Extensions to the unit or installation of additional equipment is only allowed after obtaining written approval from the manufacturer. During storage, keep the unit dry and protected from frost. 3.4 Check for complete and correct delivery of goods. Upon receipt of the unit, make sure that: Type and serial number on the name plate correspond to the order and supply information, Equipment is complete and in perfect condition. Note: Immediately file a written claim with your shipping agent in case of transport damage or missing parts. Electrical parts. Work on electrical parts must be carried out by qualified electricians. Turn off the power and secure against restart when working on electrical parts. Immediately turn the unit off when faults occur in the electrical energy supply. Only use original type fuses of correct rating. Make periodical checks of the electrical equipment. Defects, like loose connections or burned cables must be repaired immediately. Test all installed protective devices after installation or repairs (e.g. grounding). 3. Transport. 3. General. Note: Transport the air dehumidifier carefully. Prevent damage from careless loading and unloading and avoid the use of unnecessary force 3.2 Packing. Note: Observe the pictograms displayed on the carton. F Technical Data Subject to alterations

5 WET AIR PROCESS AIR HEATER REACTIVATION (90º) DRYING (270º) REACTIVATION AIR DRY AIR 4. General description. 4. Background. Modern standards concerning human comfort and the environmental requirements for manufacturing, storage & preservation of products and materials, make increasing demands on the control of moisture content in the working environment. Where the natural or treated environment have an ambient condition holding more water vapour than the specified or desirable conditions, it is necessary to integrate equipment which can reduce humidity to the desired level. FISAIR ROTARY DESICCANT DEHUMIDIFIER provide the solution. The FISAIR dehumidifier is simple to install, reliable in operation and will provide long lasting humidity control at a reasonable running cost. 4.2 The desiccant wheel. Operating principle. FISAIR series DFRA dehumidifiers operate on the adsorption property of a desiccant synthesised activated silica gel manufactured into a cylindrical wheel shape with multiple axial channels. The face of the cylinder is divided in two zones, one is for the process air and the other for a heated auxiliary air stream to reactivate the desiccant. Thus a large surface area is presented to the air streams ensuring that a rapid drying process takes place. The process air section occupies 75% or 270 degrees of the face. In this section the desiccant removes moisture from the process air passing through the rotating desiccant cylinder. The reactivation air, using a pre-heater, passes counterflow through the remaining 90 degrees section of the rotating cylinder, removing moisture from the desiccant to prepare it for the drying cycle once again. A gear motor via a pulley and driving belt rotates the cylinder at low speed to provide a continuous and uniform operation. Air seals separate the two sections and prevent air loss at the perimeter of the rotor to ensure maximum performance. F Technical Data Subject to alterations

6 b.a Figura 3. DFRA-E series explode. 4.3 Dehumidifier main components identification (fig. 3). The FISAIR series DFRA dehumidifiers consist of the following main components..- Housing module, manufactured in galvanised steel sheet with a phosphate primer coat and an enamel finish. Internally the casing is arranged to provide two separate air streams for process/dry air and regeneration/wet air with tight seals. The module is easily accessed to ensure simple inspections and maintenance of the unit. Inside is:.a. A desiccant rotor on a horizontal axis, the shaft is fixed and the wheel rotates on its hub..b. The driving geared motor with a pulley and a peripheral belt driving the rotor. 2.- Dry/Process air fan, centrifugal single entry with forward curved blades. Direct motor driven. 3.- Process air filter G4 standard. 4.- Aluminium process air flow control damper located at the air intake. 5.- Wet air/regeneration fan, centrifugal, single entry with forward curved blades, direct motor driven. 6.- Regeneration air filter G4 standard. 7.- Aluminium regeneration air flow control damper located at the air intake. 8.-Reactivation air heater (inside of main module for electrically regenerated models up to 63 kw. power). 9.-Electric control and protection box. F Technical Data Subject to alterations

7 4.4 Options and ancillary components. On demand, DFRA series of FISAIR Dehumidifiers can be provided with: Stainless steel casings. High pressure Fans (up to 600 mm WC available). Backwards curved blades fans. Fans with stainless steel impellers/casings. Pulley/Belt driven fans. More efficient air filters (up to F9). Cold water or direct expansion pre-cooling coil, with or without droplets separator. Post-cooling coil. Dry air indirect evaporative cooler. Wet air heat recovering. Wet air condenser to operate in closed circuit. Double coil (electric/steam or other thermal fluid) for the reactivation air. Integral regulating and control systems. 4.5 Regulation and control. Desiccant rotor dehumidifier drying capacity can be regulated by acting on: Reactivation heater power (lower power = lower drying capacity). Reactivation air flow (lower air flow = lower drying capacity). Process air flow, by-passing part of it over the rotor (higher by-pass = lower drying capacity). When you select the unit you have to define regulation, so that it is not a matter of this manual to extend in this aspect, but only to give an idea about possible alternatives. Note: As standard, FISAIR dehumidifiers are supplied with a hygrostat connection for On/Off operation. For electrically regenerated models, control of heater and the total unit is s u p p l i e d (bridges H,H2 or H3 of wiring diagram). F Technical Data Subject to alterations

8 5. Installation. 5. Locating the unit. Before installing FISAIR dehumidifiers the following points should be considered.» If the dehumidifier has to be stored for a significant period prior to installation it should be protected from external damage and dust and construction material. In the case of outdoor storage, weatherproof covers should be employed.» The FISAIR DFRA dehumidifier is designed for internal installation, for outdoor use please apply to your local representative for special construction details.» Once final location is defined ensure that there is enough space for servicing to be carried out. Take care to ensure that ducting connections are made without stressing the unit. 5.2 Service areas. Using the attached dimensioned drawings of the relevant model, consider periodically:» Air filters must be cleaned or changed.» The desiccant wheel faces should be inspected and cleaned and the air seals adjusted as necessary.» Driving belt should be checked for fatigue and its tightness checked. Note: In the case of the motor or belt failure they should be replaced. To do this dismount the front door which will provide space for dismounting the desiccant wheel driving device. F Technical Data Subject to alterations

9 IN HORIZONTAL DUCTS: DESCENDING DUCTS IN HORIZONTAL TRACTS TO EVACUATE CONDENSATIONS. IN VERTICAL DUCTS: IN VERTICAL TRACTS, DRILL A HOLE AT THE LOWEST PART OF THE DUCT TO DRAIN. WET AIR ISOLATING DUCTS PREVENTS CONDENSATING AIR TO PROCESS SEPARATION > 3m AIR FROM PROCESS OR OUTSIDE GRILL + MESH REACTIVATION AIR 5.3 Air duct connections.» Check the operation of fans and motors and the reactivation heater. In case of failure, repair or replace.» Check the components in the control box, service or change as necessary. Duct connections should be made using normal industry standards for air transmission systems. However, the following particular items should considered:» Make sure that available external pressures stated in the unit data-sheet have been considered when designing the ducts sizes and layout, allowing that the dehumidifier will operate with the nominal air flows.» The FISAIR dehumidifier is normally delivered with air dampers in both air streams, in order to adjust the flows to the nominal values.» The outdoor air intakes must be designed with grilles/wire meshes to avoid the involuntary carryover of raindrops, leaves, insects, etc. that could affect the correct unit operation.» The wet air outlet (normally saturated air) must be placed as far as possible from the air intakes, to avoid losses of performance.» Also, the wet air duct must facilitate the draining of the condensing water produced when this air becomes cooler due to heat transmission. To achieve this the duct must slope downstream and, if possible, be insulated. When this duct runs vertically upwards, a small drilled hole ( 5 mm. aprox.) should be arranged at the lowest part of the duct to drain the condensate that could go back to the unit or block the air duct. F Technical Data Subject to alterations

10 5.4 Electric mains connections. Attention: The dehumidifier works with medium electrical power and voltage and its connection to the mains must be done by qualified personnel and according to the applicable local electrical regulations. The unit must be connected to the electrical network of the installation through a short circuiting and ground leakage protection line, with wires section/sensitivity as corresponds to the dehumidifier power. The unit has a terminal block into the electric box sized according to the electrical standards, to connect the supply wires. 5.5 Thermal fluids connections. Dehumidifier models with steam, hot/superheated water or thermal oil reactivation coils as well as the ones with pre-or after cooling coils should be connected to the supply/return line according to good practice and local regulations. The piping layout must incorporate air vents, traps, filters, shut-off or modulating valves, and measuring devices that are demanded by the coil type of the dehumidifier. As the most usual thermal fluid is steam, this manual includes at the annex a suitable guide for steam. 5.6 Control equipment locations and connections. The location and mounting instruction for the control equipment are normally specified by the corresponding supplier. If the dehumidifier is designed to work on-off by using the H/H2 terminals of the electric control box, make sure that it operated by switching the whole unit of the heaters only. (See paragraph 4.5 of this manual) 6. Start up. Once the ductwork has been completed and the equipment is connected to the electrical mains (and to thermal fluids supply when applicable), as well as to the control equipment, proceed in this way: 6. Unit start up. Attention: Before using the control panel, verify that all mechanical elements can work freely and the unit has no installation debris inside.» Check that hygrostat set point is demanding the equipment operation (this figure should be at least 0% - 5% lower than environmental humidity), or its terminals have a bridge.» Check that the air flow regulation dampers are at least 50% opened.» Make sure that all screwed electrical terminals into the electric control box are rightly tightened to avoid faulty connections. Then, turn on the isolator switch and check that the power lamp is on. (REMARK: Do not use the isolator switch to operate the unit).» Check that the phases are connected in the correct order = fan motors and gear-motor are rotating in the right direction. To do it, switch on the equipment for a few seconds by the control switch. Note: The electrically regenerated models include a temporal relay RT, wiring diag. that keeps the fans and gear-motor working for a few minutes to dissipate the resistance heat and to avoid that the manually resetable over temperature cut out be activated.» If fans/gear-motor do not rotate in the correct direction, change the phases order at the equipment supply.» Start the unit again. Note: It is advisable to check the electric consumption of the main elements and to verify that they correspond to the nominal values. F Technical Data Subject to alterations

11 » Adjust the air flows if necessary. Note: The nominal reactivation air flow with standard heater will heat this air stream 00ºC (aprox.) above the inlet temperature. So, you can use the thermometer reading to roughly adjust the reactivation air flow.» After working for enough time to reach its standard operation (at least 30 minutes), make suitable thermohygrometric measurements. 6.2 Stopping the unit. The equipment can be stopped manually or automatically. Manual mode:» Just operate the control switch to its "OFF" position. As indicated in 6., electrically reactivated models include a timer that keeps running the fans and gearmotor for a few minutes to cool the unit. Attention: Do not stop the equipment by the isolating switch because then the timer operation will be eliminated. Automatic mode:» In case of On-Off control, the hygrostat will automatically shut-off the unit when the selected set point is reached. The electrically reactivated units can be totally stopped (after motors temporisation) or the heater only, by choosing the corresponding terminals on the wiring diagram. 6.3 Security and control components Apart from the usual electrical components protections (against shortcuts and overload at the motors, with manual reset) the electrical panel of the dehumidifier is counting with the following security and control components:» An operating thermostat (double in larger models) regulated at 50ºC (35/45ºC) to protect the heaters in case of lack of a reactivation air flow. Note: This is an automatically resetable thermostat and switches-off the heaters only.» A safety thermostat set at 60ºC (aprox.). It switches off the units completely and turns on the fault lamp. The serviceman will have them to inspect personally what was the fault at the unit.» A timer relay operating as described before. All these components are of course included into the electrically reactivated models only. The steam/thermal oil units have a simple thermometer. 7. Maintenance 7. Preventative maintenance. The following service schedule can be used. OPERATION FREQUENCY Filters cleaning Weekly Rotor driving check Weekly Fan impellers inspection Monthly Inner inspection (desiccant rotor Every second surfaces) driving belt tension month and absence of unexpected materials. Electrical consumption and Every second terminals tightening month General cleaning Yearly 7.2 Corrective maintenance The (desiccant rotor type) FISAIR dehumidifiers series DFRA have a very simple design and their components should have very few problems. The fans/motors are of standard manufacture and in case of electrical or mechanical damages any skilled serviceman may do the repairing. The heaters can be easily changed or serviced when necessary (normally after a very long working period) like any other conventional air heater element. Also, minor components like filters, dampers, driving belt and electric box components could be replaced after their useful life and the user will have to define the necessity of storing these parts, depending on their availability through local dealers. F Technical Data Subject to alterations

12 Also, minor components like filters, dampers, driving belt and electric box components could be replaced after their useful life and the user will have to define the necessity of storing these parts, depending on their availability through local dealers. 7.3 Desiccant wheel service. This is the only dehumidifier component that needs any special attention. Concerning the mechanical operation, the rotor should not require attention for a very long time. Its rotation speed is so low (20-24 r.p.h.) that the bearings and desiccant material housing cannot suffer any mechanical damage normally. However, it is very important to verify periodically the correct operation of the driving device because it directly affects the drying process. Regarding the water vapour adsorption process, the main rotor component, activated silica gel, works by fixing the water vapour molecules in its micro pores in the process air stream, leaving them when the heated reactivation air stream passes through the rotor channels. This process is not affected by the normal environmental air conditions, nor by accidents of the installation that can be expected (for example, water direct action on the rotor does not affect the material, which is also fireproof). Usual dust deposits on rotor surfaces can be removed by vacuum or blowing as well as by washing (please contact your dealer for written method when needed). F Technical Data Subject to alterations

13 8. Fault finding Inmediately switch off the dehumidifier if a fault occurs. Faults are only to be remedied by qualified personnel following the proper safety instructions. Fault The unit has stopped Check the following points Measures Electric mains are powered and the pilot lights on. If not, reset the mains protections. The fault lamp is off. If it is on, check what thermal protection (motors and heaters) switched on the lamp and stopped the unit. When you have re-set the faulty one, check and carry out corrective actions - find the reason for the failure. If fault lamp is off, check that the hygrostat set point or other signal control is demanding the equipment operation. If after these verifications the equipment does not work, please, ask the dehumidifier supplier for technical assistance. The unit works, but it does not perform as expected. Check the following points: The desiccant rotor rotates evenly at r.p.h. and if not, do the necessary service; shortening the drive belt, fixing the pulley, repairing/replacing the gear motor or adjusting the air seals, whatever is applicable. The radial and peripheral air sealings are maintaining a seal between both air streams and the outside. If not, carry out required action. The reactivation air flow, which could be reduced by clogging on the filter, damper or inlet/outlet duct. The reactivation air temperature, if this is lower than 00ºC above the inlet air temperature. In this case, check the heaters operation and the regeneration air flow. If this flow is excessive, dehumidification capacity may decrease. The process air flow could be much larger than the nominal flow. Then the specific dehumidification capacity will be lower. Regulate it by the damper. The front rotor surfaces, that could be partially blocked. F Technical Data Subject to alterations

14 9. General technical data sheet. FISAIR dehumidifier technical data Model Dry Air m3/h Nominal Capacity Kg/h(*) Reactivation Power KW (**) DFRA ,5 DFRA ,8 DFRA ,2 9,0 DFRA ,,3 DFRA ,3 3,5 DFRA ,4 5,8 DFRA ,5 8,0 DFRA ,5 22,5 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 DFRA ,0 * Nominal capacity for 20ºC and 60% R.H conditions. Other conditions call us. ** Carried out by electric heaters, steam thermal oil, gas or superheated water according to especifications. Note: Technical data are subjected to change without prior notice. F Technical Data Subject to alterations

15 0. Overall dimensions. FISAIR 4 3 ) Process Air. 2) Dry Air. 3) Reactivation Air. 4) Wet Air. 2 REFERENCIA DEL EQUIPO DIMENSIONES GENERALES MEDIDAS DE CONEXIONES A CONDUCTOS PESO A B C L H L2 H2 L3 H3 L4 H4 DFRA-0065-E DFRA-000-E DFRA-030-E DFRA-060-E DFRA-075-E DFRA-0200-E DFRA-0230-E DFRA-0300-E DFRA-0400-E DFRA-0500-E DFRA-0650-E DFRA-0900-E DFRA-00-E DFRA-300-E DFRA-700-E DFRA-200-E DFRA-2900-E DFRA-3500-E (Kg) Note : Data show correspond to electrical reactivation models. Units with other type of reactivation heater have different data. F Technical Data Subject to alterations

16 Air Dehumidifier DFRC-0400-E FISAIR TECHNICAL DATA - SHEET TECHNICAL DATA CAPACITY DIAGRAM.(*) PROCESS/DRY AIR FLOW AVAILABLE PRESSURE FOR DUCTING REACTIVATION AIR FLOW AVAILABLE PRESSURE FOR DUCTING NOMINAL DRYING CAPACITY(*) TOTAL POWER SUPPLY m/h Pa 3 m/h Pa kg/h kw DRY AIR MOISTURE CONTENT (Xs) SPECIFIC CAPACITY DIAGRAM. FISAIR DEHUMIDIFIERS. (g/kg). (ºC) Xe/Xs Xe/Ts (g/kg). PROCESS AIR MOISTURE CONTENT (Xe) DRY AIR TEMPERATURE (Ts) MOTORS POWER 3 kw SETTLED PARAMETERS : 04/04 F /B REACTIVATION HEATER POWER ELECTRICAL SUPPLY 27 kw 400V/III/50 Hz PROCESS/REACTIVATION AIR TEMPERATURE : 20 ºC ÄT REACTIVATION HEATER ACCORDING TO NOMINAL POWER EQUAL PROCESS/REACTIVATION AIR MOISTURE CONTENT (*) Nominal capacity: 20ºC and 60% R.H. (*) At other operating conditions.pls.ask for the corresponding performances. F Technical Data Subject to alterations

17 B. Overall Dimensions F Technical Data Subject to alterations

18

19 D. Spare part list for the dehumidifier DFRC-0400-E Item Main component Description Part nº Quant. Main module Dessicant rotor. Set of seals. Drive motor Transmission belt with connector Belt Connector Pulley ,4 m,2 m 2, 75m 2 Dry air fan Complete Dry air filter Filter 400X60X Dry air damper Complete Wet air fan Complete Wet air filter Filter 343x460x Wet air damper Complete Reactivation air heater Electrical heater Electric control box Pressure differential switch Temperature sensor JUMBO Microstat. Over tem perature thermostat. Motors time relay Pre-cooling coil Complete F-2832 Technical Data Subject to alterations

20 Manual de Instalación y Mantenimiento Deshumidificador de Aire por Rotor Desecante DFRA VENTILADOR DE PROCESO DEL DFRC-0400-E CMP-922-2T en mm A 388,5 B 455 H 280 C 430,5 C 357 C2 73,5 D 224 DE 278 DE 256 DE2 M8 E 80 H 34 I 204 J 282,5 J 28 K 40 K2 80 L 25 O 9,5 O 0,5 V 290 VE 220 X 4 X 50 DATOS TÉCNICOS: 400V/III/50Hz. 3 3 Qnominal ( m/h)= 2700 m/h. 3 3 QMáximo ( m /h) = 2900 m /h. 3 Pt a 2700m /h (Pa)= 373 Pa. S (rpm)= 2860 rpm. Imax. 230V= 7,8 A. Imax. 400V= 4,5 A. P (kw)= 2,2 kw. NPS= 74 db(a). ESPECTRO SONORO: Hz. Lw (dba) F-2832 El fabricante se reserva el derecho de cambiar las especificaciones sin previo aviso

21 Manual de Instalación y Mantenimiento Deshumidificador de Aire por Rotor Desecante DFRA VENTILADOR DE REACTIVACIÓN DEL DFRC-0400-E CMP-78-2T en mm A 322 B 377 B2 223 C 335,5 C 267 C2 68,5 D 200 DE 247 DE 230 DE2 M6 E 37,5 H 37 I 84 J 23 J 94,5 J2 89 K 30 K2 60 L 56 O 9 DATOS TÉCNICOS: 400V/III/50Hz. 3 3 Qnominal ( m/h)= 80 m/h. 3 3 QMáximo ( m /h) = 350 m /h. 3 Pt a 80 m /h (Pa)= 96 Pa. S (rpm)= 2850 rpm. Imax. 230V= 2,94 A. Imax. 400V=,7 A. P (kw)= 0,75 kw. NPS= 70 db(a). ESPECTRO SONORO: Hz. Lw (dba) F-2832 El fabricante se reserva el derecho de cambiar las especificaciones sin previo aviso

22 POLITEX A40 Code Name Description SF350AR4 A40 SYNTHETIC FILTER MEDIA Ventilation and industrial or civil conditioning plants. Pre-filtration and separation of particulates with medium low granulometry. dimensions roll 2x20 m composition regeneration polyester fiber yes thickness 4-6 mm max. working temperature 00 C max. working R.H. 00 % product density 350 g/m² advisable cross speed,5 m/s initial pressure drop 34 Pa final pressure drop 250 Pa avarage gravimetric efficiency 90,8 % dust holding capacity classification ( EN 779:2002) flame resistance 575 g/m² G4 F - DIN rev. 00_05 Sede - Headquarter Via S.Luca, Paese (TV) Italy Tel Fax info@generalfilter.com Div. Commerciale - Trade Office Via Caracciolo, Barbaiana di Lainate (MI) Italy Tel Fax sales.ita@generalfilter.com General Filter Italia spa si riserva il diritto di cambiare i dati della presente scheda senza alcun preavviso.

23 CONTROL DE HUMEDAD AMBIENTAL FISAIR, S.L. Departamento Dirección Técnica Abteilung Technische Leitug Department of Technical Management Départment de Direction Technique C/. Uranio, 20 - Pol. Ind. Aimayr SAN MARTIN DE LA VEGA (Madrid España) Tfº Fax DECLARACION CE DE CONFORMIDAD - EC CONFORMITY DECLARATION EG KONFORMITATSERLARüNG - DECLARATION CE DE CONFORMITÉ DECLARAMOS Bajo nuestra única responsabilidad que el deshumidificador de aire: WE DECLARE, under our sole responsability that the air dehumidifier: UNTER AUSSCHLIEßLICHER, verantwortung wird hiermit Erklärt, daß der luftentfeuchter: NOUS DECLARONS, sous notre unique responsabilité que le deshydrateur d'air: MARCA/MAKE/MARKE/MARQUE MODELO/MODEL/MODELL/MODELE FISAIR DFRC-0400-E Nº SERIE/SERIAL NUMBER/ AÑO DE FABRICACION/YEAR OF MANUFACTURE/ SERIENNUMMER/Nº DE SERIE: BAUJAHR/ANNÉE DE FABRICATION: / Se adapta a las normas: Den Normen entspricht: Meets the regulations: S'adapte aux normes:. UNE EN ISO :2004. UNE EN ISO :2004. UNE EN :999. UNE EN 294:993 Y es conforme a los requisitos esenciales de las Directivas: And conforms to the essential requirements of the Directives: Und den von den Richtlinien aufgestellten Grundvoraussetzungen Rechnung trägt: Et est conforme aux conditions essentielles des Directives:. D98/37/CEE. D73/23/CEE (Modificada por 93/68/CEE). D89/336/CEE (Modificada por 92/3/CEE y la 93/68/CEE) Con exclusión de responsabilidades sobre las partes o componentes adicionados o montados por el cliente. With no liability for the parts or components added or assembled by the customer. Unter Ausschluß der Verantwortung über die vom Kunden bereitgestellten und/oder angebauten Teile. Avec exclusion des responsabilités concernant les parties ou les composants ajoutés ou assemblés par le client. Departamento Dirección Técnica/Department of Technical Management/Départment de Direction Technique Juan Boeta Tejera. San Martin de la Vega, Septiembre 2006

Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE MODEL DFRB-090-E SERIAL Nº:

Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE MODEL DFRB-090-E SERIAL Nº: Air Humidity Control Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE MODEL DFRB-090-E SERIAL Nº: 1092910 According to the current European Union Rules on Machinery

More information

Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE DFRD SERIES

Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE DFRD SERIES Air Humidity Control Installation, Operation and Maintenance Manual AIR DEHUMIDIFIER DESICCANT ROTOR TYPE DFRD SERIES According to the current European Union Rules on Machinery Safety, the reading of these

More information

HEF7. Adiabatic Cooling System for Air-condensed Water Chillers. Installation and maintenance manual

HEF7. Adiabatic Cooling System for Air-condensed Water Chillers. Installation and maintenance manual Installation and maintenance manual HEF7 Adiabatic Cooling System for Air-condensed Water Chillers In compliance with European Union standards for machinery safety, it is essential to read this manual

More information

MULTISTAGE ELECTRIC PUMPS

MULTISTAGE ELECTRIC PUMPS MULTISTAGE ELECTRIC PUMPS Introduction: BOMBA ELIAS has developed various series of multistage pumps to cover different needs, from those of an individual house to those of large installations such as

More information

USER MANUAL DFRA SERIES

USER MANUAL DFRA SERIES USER MANUAL DFRA SERIES MUSA-EN-17-2 In compliance with the Rules and Standards of the European Union on Machine Safety, it is essential to read this protocol carefully before installing any equipment

More information

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 11 UNPACKING Carefully remove the DD200 dehumidifier unit from its transit box and visually check for signs of transit damage. If there

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models: INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank

More information

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 15 DD200 PACKAGE CONTENTS Item Description Quantity 10502SS-US Dehumidifier 1 3033807 Free plug 1 TPC356 Manual 1 Page 2 of 15 UNPACKING

More information

ECV SP GUE ALO CAT ICAL TECHN

ECV SP GUE ALO CAT ICAL TECHN TECHNICAL CATALOGUE ECV SP TAILOR MADE FOR UNITS FITTED WITH VRF SYSTEMS Models: 1001 1502 1602 2003 2303 10.16 Ref. 207609 Rev.105 CONTENT INTRODUCTION... 3 GENERAL DESCRIPTION... 3 CABINET... 3 HEAT

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL CENTRAL FANS COLASIT LTD Unit 12A, Palmers Road, East Moons Moat, Redditch. Worcs. B98 0RF Tel: 01527-517200 Fax: 01527-517195 Edition 04_13 INSTALLATION, OPERATION & MAINTENANCE MANUAL CIV Fan Range Valid

More information

EU declaration of conformity Cotes A/S Industrivej 31A DK-4230 Skaelskoer VAT no. DK CE Declares at its own l

EU declaration of conformity Cotes A/S Industrivej 31A DK-4230 Skaelskoer  VAT no. DK CE Declares at its own l COTES CROUK DEHUMIDIFIER. PRODUCTION NO. : STOCK NO. : 10100347 DOCUMENT NO. 01LK-01E INSTALLATION AND INSTRUCTION MANUAL PAGE CONTENT 1 1. Principle of operation, capacity 3 2. Applications 4 3. Dimensions

More information

Hardware User s Manual

Hardware User s Manual Hardware User s Manual Behavioral chambers References: LE26M (76-0566) Version: 1.0 Panlab, s.l.u C/Energía, 112 08940 Cornellà de Ll.(Barcelona) Spain www.panlab.com International Calls: +34 934 750 697

More information

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS TSEK VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE Tel: +90 (236) 332

More information

DanVex AD-200 Adsorption air dehumidifier. Operation manual

DanVex AD-200 Adsorption air dehumidifier. Operation manual DanVex AD-200 Adsorption air dehumidifier Operation manual CONTENT Safety instructions...3 Introduction...4 Purpose...4 Design...4 Operation principle...5 Dimensions and weight...5 Installation...6 Technical

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall

More information

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA Operating Instruction Centrifugal fans without scroll (Translation of the Original) EN RLE RLA Content 1. Important information 2. Safety notes 3.Technical description 4. Transport 5. Mounting / Installation

More information

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer MANUAL INSTALLATION OPERATION MAINTENANCE Regenerative Type Heatless Desiccant Dryer Dryspell Contents 1. Introduction 2 1.1 Design 1.2 Relevant Units 1.3 Statement of Conformity 1.4 Description 1.5 Adsorbant

More information

OIL COOLER INSTRUCTION HANDBOOK

OIL COOLER INSTRUCTION HANDBOOK OIL COOLER INSTRUCTION HANDBOOK INDEX 1. GENERALITY 2 1.1 OPERATING RANGE 1.2 IMPORTANT 2. INSTALLATION 3 2.1 TRANSPORTATION 2.2 INSTALLATION LOCATION 2.3 PIPING 2.4 WIRING (see the electrical diagram

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

DanVex AD-550 Adsorption air dehumidifier. Operation manual

DanVex AD-550 Adsorption air dehumidifier. Operation manual DanVex AD-550 Adsorption air dehumidifier Operation manual CONTENT Safety instructions...3 Introduction...4 Purpose...4 Design...4 Control board (introduction)...5 Operation principle...6 Dimensions and

More information

Hardware User s Manual

Hardware User s Manual Hardware User s Manual Isolation box Behavioral chambers References: LE26 (76-0157) Publication: PB-MF-MAN-005-REV1.0 Panlab, s.l.u C/Energía, 112 08940 Cornellà de Ll.(Barcelona) Spain www.panlab.com

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 65. Dehumidification and Drying

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 65. Dehumidification and Drying XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 65 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN TFV 900 EN OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 3 Transport and storage... 4 Start-up...

More information

COTES ALL ROUND C35E-C35D

COTES ALL ROUND C35E-C35D COTES C35E/C35D OPERATING AND SERVICE HANDBOOK page 1/101 Cotes dehumidifier C35E C35D Manual number: 140712 Revision: B COTES ALL ROUND C35E-C35D How to install, set up, operate and service your Cotes

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings 0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric

More information

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 30. Dehumidification and Drying

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 30. Dehumidification and Drying XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 30 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

Technical Catalogue. DFLEX series. Desiccant rotor air dehumidifiers

Technical Catalogue. DFLEX series. Desiccant rotor air dehumidifiers Technical Catalogue series Desiccant rotor air dehumidifiers series Desiccant rotor air dehumidifiers Index 03 General description 04 Operating principles of desiccant rotors 05 Coding product 08 Specification

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING

More information

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 35. Dehumidification and Drying

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 35. Dehumidification and Drying XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 35 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE Installation instructions For the heating engineer Installation instructions timeswitch VTS 160 GB, IE Table of contents Table of contents 1 Notes on the installation instructions...4 1.1 Observing other

More information

Service Step by Step Trouble-Shooting Check-List

Service Step by Step Trouble-Shooting Check-List WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:

More information

Desiccant Dehumidifier MDC

Desiccant Dehumidifier MDC Supplies June Page / Desiccant Dehumidifier MDC Desiccant Dehumidifier MDC Desiccant Dehumidifier MDC June Page / Dehumidifiers are intended to meet industrial and commercial needs for dry air. The heart

More information

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT Carrier International Sdn. Bhd. Malaysia INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT 40LM 120-200 50Hz CONTENTS: Physical Data & Dimension 1-3 Safety Considerations 4 Rigging

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS XXXXXXX-0 EN 1903 READ AND SAVE THESE INSTRUCTIONS INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 6000-27000 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY):

More information

ML/MLT. User s Manual 17E-30E. Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation

ML/MLT. User s Manual 17E-30E. Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation User s Manual ML/MLT 17E-30E Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation Applies to all units manufactured from week 37, 2005 190TEN-1041revC Munters Europe AB 2005 Table

More information

Manual. Atomizer Air Humidifiers. Type DG4 / DG8

Manual. Atomizer Air Humidifiers. Type DG4 / DG8 Manual Atomizer Air Humidifiers Type DG4 / DG8 1.. Instructions... 2 1.1. Operational Safety notes... 2 1.2. Transport... 2 1.3. Technical data... 3 1.4. Schematic diagram... 4 1.5. Description of Operation...

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

TECHNICAL NOTICE GH/GHO/GAE V

TECHNICAL NOTICE GH/GHO/GAE V TECHNICAL NOTICE GH/GHO/GAE V1.0-02.14 INDUSTRIAL COOLING UNITS Identification Marksa SA Industrial cooling 39, avenue du Technicum CH-2400 Le Locle Version Date Modifications 1.0 14.02.14 First edition

More information

Whole Room Dryer WRD, WRD/110

Whole Room Dryer WRD, WRD/110 Whole Room Dryer WRD, WRD/110 User Instructions Whole Room Dryers CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8117-0000 Iss.1 12/06 Fig 1 Fig 2 Fig 3 Fig 4 CONTENTS Page 1 Product information...................4

More information

Hardware User s Manual

Hardware User s Manual Hardware User s Manual References: LE760 (76-0227), LE762 (76-0228) Version: V05/11/2014 Panlab, s.l.u C/Energía, 112 08940 Cornellà de Ll.(Barcelona) Spain www.panlab.com International Calls: +34 934

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250 MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap Operation & Maintenance Manual MDX MODELS 18 THRU 250 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY

More information

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS TSEK VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE Tel: +90 (236) 332

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Waste water ejection unit

Waste water ejection unit Waste water ejection unit Over ground box SWH 500/50-80 SWH 500/50-80 Operation manual Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders...

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a

More information

IDEAL IDEAL Modular conveyor belt system. Operating Instructions

IDEAL IDEAL Modular conveyor belt system. Operating Instructions IDEAL 5009-1 IDEAL 5009-2 Modular conveyor belt system Operating Instructions 1 IDEAL 5009-1 IDEAL 5009-2 2 Table of contents 1. General... 4 1.1 Safety Instructions... 4 1.2 Application... 4 2. Installation...

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

CLIMASTER ZCF AIR HANDLING UNITS

CLIMASTER ZCF AIR HANDLING UNITS CLIMASTER ZCF AIR HANDLING UNITS From 1 September 2013, EXHAUSTO has taken over Novenco s activities within sales and production of land-based climate control systems. Inquiries relating to the products

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Operating Instructions

Operating Instructions Operating Instructions VCE2600D«««INDEX 001 TYROLIT No. 1099105912345678 de / dd.mm.yyyy19.04.2011 Congratulations! You have decided to purchase a tried and tested TYROLIT-Hydrostress unit and have thus

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air Curtains RUND Please, read these instructions carefully before attempting installation SECURITY ADVISE SYMBOLS Attention, Danger, Safety Advice! Danger

More information

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T50 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-203 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Operation & Maintenance Manual MODELS MDX 800 1000 1200 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY 2 1.0

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

EDD61 & EDD91 Extractors

EDD61 & EDD91 Extractors EDD61 & EDD91 Extractors Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

INSTALLATION AND OPERATING MANUAL OF THE BASIC CONTROL PANEL (CCB) FOR THE FISAIR EVAPORATIVE HUMIDIFIERS

INSTALLATION AND OPERATING MANUAL OF THE BASIC CONTROL PANEL (CCB) FOR THE FISAIR EVAPORATIVE HUMIDIFIERS 0 0 I INSTALLATI AND OPERATING MANUAL OF THE BASIC CTROL PANEL (CCB) FOR THE FISAIR EVAPORATIVE HUMIDIFIERS Software Version 8.0 MCCB-EN-17-1 In fulfilment of the Regulations of the European Union on Machine

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original

More information

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK BARTELL MORRISON INC. 375 Annagem Blvd., Mississauga, ON L5T 3A7 Telephone: 1-647-953-4100 Fax: 1-647-953-4101 BCF1080 FORWARD PLATE COMPACTORS Doc. # PB-B19017 Orig. Rel. 10/2013 Curr Rev. - 06 Bartell

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR HRV H 00 ERV H 00 HRV H 300 ERV H 300 EN OPERATION MANUAL HRV /ERV H 00(300) www.blaubergventilatoren.de CONTENTS Application... Delivery set...3 Unit designation key...3 Basic

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

The CE Marking Access to the European Market

The CE Marking Access to the European Market The CE Marking Access to the European Market The EU dictates the compliance of guidance and a CE marking for many industrial products, so that these products may attain to the market. The experts of Eurofins

More information

NEWGATE TECHNOLOGIES, INC.

NEWGATE TECHNOLOGIES, INC. www W.newgatetechnologies.com NEWGATE TECHNOLOGIES, INC. Installation & Operations Manual SYNERGY Series High Inlet Temperature Refrigerated Air Dryers Models SYNERGY 025 ~ SYNERGY 125 Includes Safety

More information

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Air curtain SMART

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Air curtain SMART INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air curtain SMART Read instructions carefully before attempting installation. Deliver this manual to end user. SECURITY ADVISE SYMBOLS Attention, Danger,

More information

Use and maintenance Manual Longitudinal profile welding Model: LRW-130

Use and maintenance Manual Longitudinal profile welding Model: LRW-130 LRW-130 1300 mm. IMPORTANT: Read this user manual and follow the instructions and warnings before operating this device. Any modification or transformation performed on this machine may cause loss of the

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

INSTRUCTION MANUAL FOR USE AND MAINTENANCE

INSTRUCTION MANUAL FOR USE AND MAINTENANCE R.ESPINAR, S.L. INSTRUCTION MANUAL FOR USE AND MAINTENANCE BACTERIOLOGICAL AND CULTURE INCUBATORS INCUTERM Models: ID-20 ID-40 ID-50 ID-90 ID-150 ID-288 1 / 13 It is very important to keep these instructions

More information

OPERATION AND MAINTENANCE BOOK. Glycol Deck 250 PREAMBLE

OPERATION AND MAINTENANCE BOOK. Glycol Deck 250 PREAMBLE OPERATION AND MAINTENANCE BOOK Glycol Deck 250 Document Code: 0150GLDECEN.000 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties without our authorization.

More information

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR Elite-Silent Elite-Silent READ CAREFULLY BEFORE USING THE MACHINE Version 08/02 Generalities The body of the

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel. DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the

More information

AFD Industrial Dehumidifier Series

AFD Industrial Dehumidifier Series Dryomatic HUMIDITY CONTROL A MEMBER OF MARDUK HOLDING COMPANY LLC AFD Industrial Dehumidifier Series DRYOMATIC is a Leader in the Dehumidification Industry with Over 5 Years Experience and Thousands of

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

Owner s Manual Phoenix 1200 Desiccant Dehumidifier PO Box 8680 Madison, WI 53708 Owner s Manual Phoenix 1200 Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 1200 Portable Desiccant Dehumidifier

More information

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance EST-X Figure 1. EST-X unit. Removable top panel D Control module located internally External Commissioning box Table 1. EST-X Dimensions (mm) Weight Code A B C D dia. (kg) EST1-X 705 505 355 125 22 EST2-X

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information