1 Outdoor Units Part 3 Outdoor Units 1. Dimensions Service Space Piping Diagrams Wiring Diagrams Electric Characteristics Operation Limits Sound Levels Outdoor Units

2 Dimensions 1. Dimensions Model Unit mm A B C D E F H MOU-12HDN1-Q MOU-18HDN1-Q MOU-24HDN1-Q MOU-30HDN1-Q MOU-36HDN1-Q MOU-36HDN1-R Outdoor Units 119

3 Dimensions Model MOU-48HDN1-Q MOU-48HDN1-R MOU-60HDN1-R A B C D E F H Unit mm Outdoor Units

4 Dimensions New MOU-48HDN1-Q MOU-48HDN1-R MOU-60HDN1-R Outdoor Units 121

5 Service Space 2. Service Space (Wall or obstacle) Air inlet More than 30cm Air inlet Air outlet More than 30cm Maintain channel More than 60cm More than 200cm More than 60cm 122 Outdoor Units

6 Piping Diagrams 3. Piping Diagrams MOU-12HDN1-Q INDOOR OUTDOOR LIQUID SIDE CHECK VALVE (Heating Model only) 2-WAY VALVE CAPILIARY TUBE T3 Condenser (EVAPORATOR) T1 Room temp. sensor T4 Ambient (CONDENSER) T2 Evaporator GAS SIDE 4-WAY VALVE 3-WAY VALVE Accumulator Compressor T5 Discharge COOLING ING MOU-24HDN1-Q( ) INDOOR OUTDOOR LIQUID SIDE CHECK VALVE (Heating Model only) 2-WAY VALVE CAPILIARY TUBE T3 Condenser (EVAPORATOR) T2 Evaporator middle T1 Room temp. sensor T4 Ambient (CONDENSER) T2B Evaporator outlet GAS SIDE 4-WAY VALVE 3-WAY VALVE Accumulator Compressor T5 Discharge COOLING ING For MOU-24HDN1-Q, the accumulator is not included. Outdoor Units 123

7 Piping Diagrams MOU-18HDN1-Q MOU-24HDN1-Q( ) INDOOR OUTDOOR LIQUID SIDE CAPILIARY TUBE Electronic expansion valve 2-WAY VALVE T3 Condenser (EVAPORATOR) T2 Evaporator middle T1 Room temp. sensor T4 Ambient (CONDENSER) T2B Evaporator outlet GAS SIDE 4-WAY VALVE 3-WAY VALVE Accumulator Compressor T5 Discharge COOLING ING For MOU-24HDN1-Q, the accumulator is not included. MOU-30HDN1-Q INDOOR OUTDOOR LIQUID SIDE CAPILIARY TUBE Electronic expansion valve 2-WAY VALVE T3 Condenser (EVAPORATOR) T2 Evaporator middle T1 Room temp. sensor T4 Ambient (CONDENSER) T2B Evaporator outlet GAS SIDE 4-WAY VALVE 3-WAY VALVE Accumulator Low pressure switch Compressor High pressure switch T5 Discharge COOLING ING 124 Outdoor Units

8 Piping Diagrams MOU-36HDN1-Q MOU-36HDN1-R MOU-48HDN1-Q MOU-48HDN1-R MOU-60HDN1-R INDOOR OUTDOOR LIQUID SIDE CAPILIARY TUBE Electronic expansion valve 2-WAY VALVE T3 Condenser (EVAPORATOR) T2 Evaporator middle T1 Room temp. sensor T4 Ambient (CONDENSER) T2B Evaporator outlet GAS SIDE 4-WAY VALVE 3-WAY VALVE Accumulator Low pressure switch Compressor High pressure switch T5 Discharge Oil separator COOLING Oil return Capillary ING For MOU-48HDN1-Q, MOU-48HDN1-R and MOU-60HDN1-R, the accumulator is not included. Outdoor Units 125

9 Wiring Diagrams 4. Wiring Diagrams MOU-12HDN1-Q MOU-18HDN1-Q 126 Outdoor Units

10 Wiring Diagrams MOU-24HDN1-Q ( ) MOU-24HDN1-Q ( ) Outdoor Units 127

11 Wiring Diagrams MOU-30HDN1-Q MOU-36HDN1-Q( ) 128 Outdoor Units

12 Wiring Diagrams MOU-36HDN1-Q( ) Outdoor Units 129

13 Wiring Diagrams MOU-48HDN1-Q MOU-48HDN1-Q (New Body) 130 Outdoor Units

14 Wiring Diagrams MOU-36HDN1-R MOU-48HDN1-R MOU-60HDN1-R Outdoor Units 131

15 Wiring Diagrams MOU-48HDN1-R MOU-60HDN1-R (New Body) 132 Outdoor Units

16 5. Electric Characteristics Model Electric Characteristics Outdoor Unit Hz Voltage Min. Max. MOU-12HDN1-Q MOU-18HDN1-Q MOU-24HDN1-Q MOU-30HDN1-Q MOU-36HDN1-Q MOU-36HDN1-R MOU-48HDN1-Q MOU-48HDN1-R MOU-60HDN1-R Outdoor Units 133

17 Operation Limits 6. Operation Limits Temperature Mode Cooling operation Heating operation Room temperature Outdoor temperature For the models with low temperature cooling system CAUTION: 1. If the air conditioner is used beyond the above conditions, certain safety protection features may come into operation and cause the unit to operate abnormally. 2. The room relative humidity should be less than 80%. If the air conditioner operates beyond this figure, the surface of the air conditioner may attract condensation. Please set the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode. 3. The optimum performance will be achieved during this operating temperature zone. 134 Outdoor Units

18 Sound Levels 7. Sound Levels Outdoor Unit Microphone H 1.0m Note: H= 0.5 height of outdoor unit Model Noise level db(a) H MOU-12HDN1-Q 48 MOU-18HDN1-Q 51 MOU-24HDN1-Q ( ) 54 MOU-24HDN1-Q ( ) 59 MOU-24HDN1-Q ( ) 55 MOU-30HDN1-Q 55 MOU-36HDN1-Q 55 MOU-36HDN1-R 63 MOU-48HDN1-Q 59/54 MOU-48HDN1-Q(New Body) 62 MOU-48HDN1-R 62 MOU-48HDN1-R (New Body) 62.5 MOU-60HDN1-R 63 MOU-60HDN1-R (New Body) 62 Outdoor Units 135

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit. SERVICE MANUAL Indoor unit Outdoor unit 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* INDEX PART1 GENERAL INFORMATION PART2 ELECTRICAL DIAGRAM PART3 TROUBLE

More information

SERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER

SERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER SERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER i Contents CONTENTS Part 1 General Information... 1 Part 2 Indoor Units... 5 Part 3 Outdoor Units... 32 Part 4 Installation...

More information

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING TROUBLESHOOTING AIR CONDITIONER KTIR SERIES Thank you very much for purchasing our air conditioner, please read this owner's manual carefully before using your air conditioner TROUBLES AND CAUSES Before

More information

DC INVERTER SERIES. Service Manual 2013 LIS-E-1312

DC INVERTER SERIES. Service Manual 2013 LIS-E-1312 DC INVERTER SERIES Service Manual 2013 LIS-E-1312 Contents Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 65 Part 4 Installation... 74 Part 5 Electrical Control System...

More information

Energy Related Products SUPER DC INVERTER SERIES

Energy Related Products SUPER DC INVERTER SERIES Energy Related Products SUPER DC INVERTER SERIES Service Manual 2013 LFIS-B-1309 Contents i Contents Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 65 Part 4 Installation...

More information

Multi Splits Series. DKH Indoor Units DBC Indoor Units DAQ Indoor Units DCD Indoor Units Outdoor Units JOSI-DKH009-N11

Multi Splits Series. DKH Indoor Units DBC Indoor Units DAQ Indoor Units DCD Indoor Units Outdoor Units JOSI-DKH009-N11 Multi Splits Series DKH Indoor Units DBC Indoor Units DAQ Indoor Units DCD Indoor Units Outdoor Units JOSI-DKH009-N11 JOAU-ZCY218-H11 JOSI-DKH012-N11 JOSI-DBC012-N11 JOSI-DAQ012-N11 JOSI-DCD012-N11 JOAU-ZCY327-H11

More information

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual Super-Slim Four-Way Cassette CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing

More information

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W Energy- Saving Mode Window AC 12000BTU MODEL: 12000BTU 11.2 Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

KSD-35 DR11 KUE-35 DVN11

KSD-35 DR11 KUE-35 DVN11 FLOOR-STANDING TYPE AIR CONDITIONER Owner s Manual Floor-Standing Type KSD-35 DR11 KUE-35 DVN11 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

SUPER DC INVERTER SERIES

SUPER DC INVERTER SERIES Energy Related Products SUPER DC INVERTER SERIES Service Manual 2016 LFIS-C1-1601 Contents i Contents Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 94 Part 4 Installation...

More information

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES Middle Static Pressure Duct Type KDIR SERIES Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.

More information

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES CONTENTS 1. Precaution... 1 1.1 Safety Precaution...1 1.2 Warning...1

More information

Multi zone. MULTI OUTDOOR UNITsS. CONDENsSING UNITsS. Revision V1.0: Table of Contents

Multi zone. MULTI OUTDOOR UNITsS. CONDENsSING UNITsS. Revision V1.0: Table of Contents MULTI OUTDOOR UNITsS sservice MANUAL Multi zone CONDENsSING UNITsS Revision V1.0: 20160616 Table of Contents 1. Indoor Unit Combination 2. Suggested Indoor Unit Model Numbers 3. Dimension Of Outdoor Unit

More information

F SERIES ON-OFF SERIES. Service Manual 2016

F SERIES ON-OFF SERIES. Service Manual 2016 F SERIES ON-OFF SERIES Service Manual 2016 CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Function... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 9 4. Refrigerant

More information

SERVICE MANUAL. Spilt Air Conditioner unit Ceiling & Floor Type FSPI-180AE1 / FSOIF-180AE1 FSPI-240AE1 / FSOIF-240AE1

SERVICE MANUAL. Spilt Air Conditioner unit Ceiling & Floor Type FSPI-180AE1 / FSOIF-180AE1 FSPI-240AE1 / FSOIF-240AE1 SERVICE MANUAL Spilt Air Conditioner unit Ceiling & Floor Type FSPI-180AE1 / FSOIF-180AE1 FSPI-240AE1 / FSOIF-240AE1 FI_SM_FSPI-180-240-AE1_20131010 1 Part 1 Indoor units 1. Features... 3 2. Dimensions...

More information

Buttons on remote controller

Buttons on remote controller Buttons on remote controller 1 2 3 4 5 2 1 6 7 3 8 5 6 4 7 10 8 10 15 15 ON/OFF button button MODE button SWING button FAN button Introduction for icons on display screen button TIMER OFF button CLOCK

More information

MULTI INVERTER SERIE H6M

MULTI INVERTER SERIE H6M MULTI INVERTER SERIE H6M Service manual www.mundoclima.com Thank you very much for purchasing our products. Please read this manual carefully before installing and using the unit. ODMFI-B1-1606 CL20440

More information

Remote Controller Manual

Remote Controller Manual Wall Mounted AIR CONDITIONER Remote Controller Manual KS Series KS09 KS12 KS18 KS24 KS28 + Mode Fan - J3498_Kaden_Controller Manual_280817.indd 1 J3498_Kaden_Controller Manual_280817.indd 2 Table of Contents

More information

KMIR218-H221 / KMIR327-H217 / KMIR436-H217 / KMIR545-H219

KMIR218-H221 / KMIR327-H217 / KMIR436-H217 / KMIR545-H219 Multi outdoor units SERVICE MANUAL Multi - Zone heat pump units Model Numbers: KMIR218-H221 / KMIR327-H217 / KMIR436-H217 / KMIR545-H219 Table of Contents 1. Indoor Unit Combination 2. Suggested Indoor

More information

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON. Trip of breaker or The breaker trips at once when it is set to O. Measure insulation resistance to ground to see if there is any leakage. Air conditioner can not start up blow of fuse The air conditioner

More information

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W WALL MOUNTED UNITS Technical Dossier WALL MOUNTED UNITS SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W 2010 1- CONTENTS 1- Contents... 2 2- Technical specifications... 3 3- Temperature by capacities...

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SERVICE MANUAL K LIGHT COMMERCIAL

SERVICE MANUAL K LIGHT COMMERCIAL SERVICE MANUAL 36 48 60K LIGHT COMMERCIAL Cassette indoor unit Under-ceiling indoor unit Ducted indoor unit 42QTD036DS* 42QTD048DS* 42QTD060DS* 42QZL036DS* 42QZL048DS* 42QZL060DS* 42QSM036DS* 42QSM048DS*

More information

Installation, Operation & Maintenance

Installation, Operation & Maintenance Installation, Operation & Maintenance Contura 5G Series R410a High Ambient & High Efficiency MS-SVX041A-EN 1 Contents 1. Precaution 1.1 Safety Precuation 03 1.2 Warning 03 2. Product Specifications 06

More information

Mobile Type Air Conditioner

Mobile Type Air Conditioner Mobile Type Air Conditioner 1. Features 2. Specification 3. Wiring diagram 4. Trouble shooting 5. Electronic function 36 1. Features 1.1The currently manufactured mobile air conditioners include the following

More information

Operating Functions Temperature Parameters

Operating Functions Temperature Parameters Operating Functions Temperature Parameters Room set temperature (T set) Room ambient temperature (T amb) Fundamental Functions After powered on, no matter when the compressor is started, the time interval

More information

Floor-Standing Type(E Series)

Floor-Standing Type(E Series) Floor-Standing Type(E Series) Model: MFE-60CE, MFE-60AE Part 1. Product Features With a spiral shape, the computer-aided simulation designed air passage system can efficiently reduce noise. The Soft touch

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz IDETECH R NE IDETECH SERVICE MANUAL PORTABLE AIR CONDITIONER AP-237EB Important points on service, and flow chart for inspecting and repairing the unit... 1 Appearance(out ward)... 2 Troubleshooting...

More information

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

KTIR AIR CONDITIONER SERIES OWNER S MANUAL

KTIR AIR CONDITIONER SERIES OWNER S MANUAL , OWNER S MANUAL AIR CONDITIONER KTIR SERIES Thank you very much for purchasing our air conditioner, please read this owner's manual carefully before using your air conditioner CONTENT IMPORTANT SAFETY

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

Service Manual AIR CONDITIONER

Service Manual AIR CONDITIONER Service Manual AIR CONDITIONER DC INVERTER MULTI TYPE This manual applies to models: High Wall Duct Cassette Console Universal CDU 42QHF009DS 42QHF012DS 42QHF018DS 42QSM009DS 42QSM012DS 42QSM018DS 42QTD009DS

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR C18 GE AIR C24 GE AIR C34 GE AIR C41 1 Introduction and Features Model Remarks

More information

Light Commercial SUPER INVERTER SERIES MULTI TYPE

Light Commercial SUPER INVERTER SERIES MULTI TYPE Light Commercial SUPER INVERTER SERIES MULTI TYPE Service Manual 2017 CONTENTS 1. General information of Indoor Units... 1 2. Features... 2 3. Dimensions... 12 4. Service Space (unit: mm)... 19 5. Wiring

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

Westinghouse. Split System Inverter Series. Service Manual

Westinghouse. Split System Inverter Series. Service Manual Westinghouse Split System Inverter Series Service Manual Model: WIWPK/WCHPK Range: 2.6kw 7.6kw CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 5 3. Dimension... 6

More information

Service Manual. Procedure. 4. Remove top cover. Top cover sub-assy. Remove the screws fixing top cover and then remove the top cover.

Service Manual. Procedure. 4. Remove top cover. Top cover sub-assy. Remove the screws fixing top cover and then remove the top cover. 4. Remove top cover Top cover sub-assy Remove the screws fixing top cover and then remove the top cover. 5. Remove electric box 1 Twist off screws fixing the electric box, pull out compressor wires and

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

NORTH AMERICAN HVAC PRODUCTS LTD 3208 BETA AVE, BURNABY BC V5G 4K4 CSNA-1305-A SERVICE MANUAL AIR CONDITIONER SPLIT WALL-MOUNTED TYPE.

NORTH AMERICAN HVAC PRODUCTS LTD 3208 BETA AVE, BURNABY BC V5G 4K4 CSNA-1305-A SERVICE MANUAL AIR CONDITIONER SPLIT WALL-MOUNTED TYPE. NORTH AMERICAN HVAC PRODUCTS LTD 3208 BETA AVE, BURNABY BC V5G 4K4 CSNA-1305-A SERVICE MANUAL AIR CONDITIONER SPLIT WALL-MOUNTED TYPE Corona Series CONTENTS 1. Precaution... 1 1.1 Safety Precaution...

More information

COOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER MANUAL. 10,000 BTU to 60,000 BTU Capacities IS T E D ISO 9001, ISO 14001

COOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER MANUAL. 10,000 BTU to 60,000 BTU Capacities IS T E D ISO 9001, ISO 14001 CM COOLING SOLUTIONS A Division Of CAG Purification Inc. SPOT COOLER MANUAL 10,000 BTU to 60,000 BTU Capacities C L IS T E D US ISO 9001, ISO 14001 1 Preface Based on our policy of continuous Research

More information

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

POLICY BULLETIN Tecumseh Compressor Company Compressor Group PAGE: 1 of 4 A rotary compressor is a precision piece of equipment, designed and manufactured to very close tolerances. For superior performance and long term reliability the following parameters must

More information

[U] Serie MOV. Manual de Ingeniería

[U] Serie MOV. Manual de Ingeniería [U] Serie MOV Uniidades Condensadoras (Fllujjo Verttiicall) 6..3,, 8 y 12..5 Ton Manual de Ingeniería - 112- Outdoor Units_MOV 1. Specifications.... 2. Dimension... 3. Service Space. 4. Piping Diagrams

More information

C&H NORDIC Commercial 4 SERVICE MANUAL

C&H NORDIC Commercial 4 SERVICE MANUAL C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...

More information

YC ON-OFF SERIES. Service Manual

YC ON-OFF SERIES. Service Manual YC ON-OFF SERIES Service Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Model Lists... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 11 4. Refrigerant

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

FROZEN SERIE SERVICE MANUAL. DC Inverter R32. Sistemi per la climatizzazione

FROZEN SERIE SERVICE MANUAL. DC Inverter R32. Sistemi per la climatizzazione DC Inverter R32 Sistemi per la climatizzazione SERVICE MANUAL FROZEN SERIE CONTENTS 1. General information of Outdoor Units... 3 2. Features... 4 3. Dimensions... 5 4. Refrigeration Cycle Diagram... 6

More information

Table 1. Serie of Digital Room Thermostats.

Table 1. Serie of Digital Room Thermostats. Digital Room Thermostats INSTALLATION MANUAL APPLICATION DR is a serie of Digital Room Thermostats, provides a single stage, temperature control. Table 1 shows all the available models. All models can

More information

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Bosch Split-Type Ductless Air Conditioner / Heat Pump Bosch Split-Type Ductless Air Conditioner / Heat Pump Climate 5000 AA Series Service Manual 2 Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner / Heat Pump Service Manual Data subject to

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR

More information

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS... AC100-R CONTENTS 1 SAFETY INSTRUCTIONS.. 2 2 FEATURES AND OPERATION.... 3 3 PARTS LIST AND INSTALLATION. 4 4 CONTROL PANEL AND SETTINGS... 5 6 MAINTENANCE 6 7 TROUBLE SHOOTING.. 7 8 APPENDIX. 8 1 SAFETY

More information

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A No. :WXXS-000-GGSY-12 APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR MODEL C-SBR180H16A NO. DATE PAGE REVISION DETAILS SANYO SIGNED CLIENT SIGNED REVISION RECORD USER: MANUFACTURER: DALIAN

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

SPLIT-TYPE ROOM AIR CONDITIONER

SPLIT-TYPE ROOM AIR CONDITIONER Residential & Light Commerical Unit User s Manual New Released Form: U-Remote RG94-600 SPLIT-TYPE ROOM AIR CONDITIONER Remote Controller RG94 06 Johnson Controls, Inc. www.johnsoncontrols.com Doc. No.:

More information

DVC/DVH 09/12/18/24 Series

DVC/DVH 09/12/18/24 Series Remote Controller Manual DVC/DVH 09/1/18/4 Series Inverter Single Zone Ductless Mini-Split www.marsdelivers.com CONTENTS Remote controller Specifications... Operation of buttons...... Indicators on LCD...

More information

CASSETTE TYPE AIR CONDITIONER

CASSETTE TYPE AIR CONDITIONER CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

SUPER DC INVERTER MULTI TYPE INSTRUKCJA SERWISOWA

SUPER DC INVERTER MULTI TYPE INSTRUKCJA SERWISOWA ODMFI-B-1211 INSTRUKCJA SERWISOWA SUPER DC INVERTER MULTI TYPE K2OD-14HFN1-Q, K2OD-18HFN1-Q, K3OD-21HFN1-Q K3OD-27HFN1-Q, K4OD-28HFN1-Q, K4OA-36HFN1-Q K5OC-36HFN1-Q DC MULTI OUTDOOR UNITS CONTENTS 1. General

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 7 3.1 Indoor

More information

OWNER S MANUAL VMH 09/12/18/24

OWNER S MANUAL VMH 09/12/18/24 OWNER S MANUAL VMH 09/12/18/24 Version C Inverter Single Zone Ductless Mini-Split Heat Pump Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com VMH Inverter

More information

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units FS2MIF-140AE2 FS2MIF-180AE2 FS3MIF-210AE2 FS3MIF-270AE2 FS4MIF-280AE2 FS4MIF-360AE2 FS5MIF-360AE2 NOTE: Before servicing the unit,

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures

More information

SEMTIC HEATING

SEMTIC HEATING SEMTIC HEATING www.ttshop.se Luxury Air Source Heat Pump - Touch Screen Operation Manual - AXAO-06 AXAO-08 AXAO-11 AXAO-14 AXAO-14/3 AXAO-16/3 AXAO-21/3 0 Operation instruction 1. Main page 1.1. It shows

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

KSIM20912-H216 KSIM30912-H216 KSIM40912-H216

KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 SERVICE MANUAL KLIMAIRE AIRCONDITIONER KSIM DC INVERTER MULTI TYPE KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 DC MULTI OUTDOOR UNITS CONTENTS 1. General information of Outdoor Units...3 2 Features...4

More information

Multi zone Two, Three, Four and Five Zones

Multi zone Two, Three, Four and Five Zones MULTI SPLIT SYSTEM OUTDOOR UNITS SERVICE MANUAL Multi zone Two, Three, Four and Five Zones DC INVERTER MULTI ZONE OUTDOOR UNITS Revision A: ODMI E 1601 PDB55/2016 Model Numbers: YN020GMFI22M2D YN030GMFI22M3D

More information

Mono DC. VERTU MONO Split DC Inverter Air Conditioner SERVICE MANUAL MSV1-18HRDN1-MQ0W. Revision A: , Content updated.

Mono DC. VERTU MONO Split DC Inverter Air Conditioner SERVICE MANUAL MSV1-18HRDN1-MQ0W. Revision A: , Content updated. VERTU MONO Split DC Inverter Air Conditioner SERVICE MANUAL Mono DC Revision A: 1305080001, Content updated. Model Numbers: 0 MSV1-09HRFN1-MT0W MSV1-12HRDN1-MQ0W MSV1-24HRDN1-MQ0W MSV1-12HRFN1- MT0W MSV1-18HRDN1-MQ0W

More information

SEER 15 DC INVERTER SERIES

SEER 15 DC INVERTER SERIES NORTH AMERICAN HVAC PRODUCTS LTD Address: 3208 Beta Ave, Burnaby BC Canada V5G 4K4 Tel: 604-4308496 Fax: 1-866-9034371 WWW.NORTHAMERICANHVAC.COM SEER 15 DC INVERTER SERIES Service Manual 2013 SINGLE ZONE

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

High Wall Split Air Conditioners 53QHCT KHCT

High Wall Split Air Conditioners 53QHCT KHCT Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. R22 220-240V ~ 50Hz 1Ph High Wall Split Air Conditioners 53QHCT 12-18-24 53KHCT 12-18-24 Heat Pump Cool Only OWNER S MANUAL Carrier is committed to

More information

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference. OPERATING MANUAL SENSOR ON/OFF AUTO COOL TEMP HIGH MED LOW DRY HEAT MODE TIMER SWING SLEEP Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

REPAIR PARTS LIST For Parts or Service: Call MY-HOME ( ) Or Visit

REPAIR PARTS LIST For Parts or Service: Call MY-HOME ( ) Or Visit REPAIR PARTS LIST 253.76250410 253.76250411 ROOM AIR CONDITIONER In all orders or correspondence, avoid delays and misunderstandings by always giving the complete model number shown on the front of the

More information

KSIN INVERTER SERIES Service Manual 2013

KSIN INVERTER SERIES Service Manual 2013 KSIN INVERTER SERIES Service Manual 2013 CONTENTS 1. Precaution............ 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function............ 6 3. Dimension............ 8 3.1 Indoor Units... 8 3.2

More information

HABITAT USER MANUAL TIN310**V33 TIN414**V33 TIN520**V33 TIN625**V33 TIN1036H2V02 TIN1939H2V02 INVERTER MINI SPLIT

HABITAT USER MANUAL TIN310**V33 TIN414**V33 TIN520**V33 TIN625**V33 TIN1036H2V02 TIN1939H2V02 INVERTER MINI SPLIT HABITAT INVERTER MINI SPLIT USER MANUAL TIN310**V33 TIN414**V33 TIN520**V33 TIN625**V33 TIN1036H2V02 TIN1939H2V02 WARNING The information contained in the manual is intended for use by a qualified service

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE031229 Models TAC-07CS/K TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CSC/K TAC-09CSC/K TAC-12CSC/K TAC-18CSC/K TAC-24CSC/K TAC-07CHS/K

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Accessories Weather and Sound Enclosures Applicable to the following: 30-125RZG 25/30//1RZGB Kohler enclosures protect stationary generator sets from the elements, animal intrusion, and unwanted

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners 763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000

More information

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use. English Table of Contents 1. Accessories ------------------------------------------------------------------------1 2. Introduction--------------------------------------------------------------------------2

More information

Air Conditioners. Technical Data FTXS-G

Air Conditioners. Technical Data FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE

More information