These instructions are updated on a regular basis. Please visit our web site at

Size: px
Start display at page:

Download "These instructions are updated on a regular basis. Please visit our web site at"

Transcription

1 H ULTIMA XT These instructions are updated on a regular basis. Please visit our web site at Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 1 of 15

2 Packing List QTY ITEM 1 APOGEE XT water-block, including socket 1366, socket 1156 and socket 775 hold-down plates for all Intel Core desktop microprocessors. Important note: Free Upgrade available (see terms and conditions) for AMD socket 754, 939, and AM2, as well as Intel socket 771 (Xeon series) Server form factor 1 MCP655-B pump, including mounting hardware and (2) ½ hose clamps 1 MCRES-Micro Rev. 2, including ½ hose-barb fittings, and hose clamps, bracketry & hardware for various installation: 1 L bracket, 2 U brackets 1 MCR220 Radiator assembly, including (2) pre-installed 120mm fans with fan guards, mounting hardware, ½ black nylon hose barb fittings, (2) 12v to 7v adapters, (2) 12v to 5v 3-pin to 4-pin Molex adapters, and (2) hose clamps And Pre-installed MCB-120 Radbox, with mounting hardware 6 Feet 1/2 ID (3/4 OD) Clearflex tubing 1 2 Oz. Bottle of HydrX concentrated coolant 1 Syringe of Arctic Céramique thermal compound Warning! The Apogee XT water-block included with your kit is compatible with all the most popular processors available on the market. In an effort to cut on waste however, some of the less popular mounting mechanisms have not been physically included in the kit and are available for free on demand. They are: Hold-down plate for Intel legacy server platforms (socket 771, Xeon) Hold-down plate for AMD socket 754, 939, F and AM2 If you own one of the above platforms, all you have to do is contact customer support and the part will be shipped to you at no charge by express mail or equivalent. The following terms and conditions apply: Worldwide except Europe: Please within 90 days of your date of purchase (proof of purchase required), call, write or Fax to Swiftech customer service at: TOLL FREE (Continental US only) SWIFT ( ) Mailing Address Swiftech 151 West Victoria St. Long beach, CA USA Telephone Fax Europe: Please rma@bacata.net within 90 days of your date of purchase (proof of purchase required) Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 2 of 15

3 TABLE OF CONTENTS I. PLANNING General Guidelines Tube Routing... 4 II. INSTALLATION OF THE COOLING COMPONENTS MCR220 Radiator installation... 6 General concept schematic... 6 Installation APOGEE XT Water-block installation Re-installing the motherboard Pump installation... 9 General Use... 9 Physical installation... 9 Pump operating precautions: MCRES-Micro reservoir Installation Installation Preparing the coolant Installing the tubing Completing the installation Re-installing your power-supply Filling-up the circuit Troubleshooting Draining the system Periodic Maintenance Optional Components Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 3 of 15

4 INTRODUCTION Congratulations on your purchase of a Swiftech H20-APEX liquid cooling system! This kit has been designed to facilitate the installation of the components with a minimum of case modifications. While all attempts have been made to make the installation of this system user friendly, please note that this system is intended for users that are well versed in installing computer components. DISCLAIMER While all efforts have been made to provide the most comprehensive tutorial possible, Swiftech assumes no liability expressed or implied for any damage(s) occurring to your components as a result of using Swiftech cooling products, either due to mistake or omission on our part in the above instructions, or due to failure or defect in the Swiftech cooling products. In addition, Swiftech assumes no liability, expressed or implied, for the use of this product, and more specifically for any, and all damages caused by the use of this product to any other device in a personal computer, whether due to product failure, leak, electrical short, and or electro-magnetic emissions. WARRANTY Our products are guaranteed for 12 months from the date of delivery to the final user against defects in materials or workmanship. During this period, they will be repaired or have parts replaced provided that: (I) the product is returned to the agent from which it was purchased; (II) the product has been purchased by the end user and not used for hire purposes; (III) the product has not been misused, handled carelessly, or other than in accordance with any instructions provided with respect to its use. This guarantee does not confer rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an extra benefit and does not affect your statutory rights as a consumer. I. Planning 1. GENERAL GUIDELINES Please read this guide carefully and entirely before you start this installation. Plan your installation ahead. Observe the relative position of the components for possible interference with other components. Never work with electricity connected to the computer while work is in progress. Because some work is necessary that will require cutting holes in the case, it is strongly recommended to remove all the components from the case prior to begin with this installation. After the metal work has been completed, carefully clean the case to remove all metal debris. Once the time has come to re-install the motherboard and complete the liquid-cooling circuit, the motherboard should be disconnected from the power-supply at all times during the entire mock-up phase of the installation. In case of a spill or leak on the motherboard, do not panic! As long as the motherboard is not electrically connected, no harm is done. You must however thoroughly dry the exposed area, using a hair dryer for example, and wait a minimum of 6 to 8 hours prior to reconnecting the motherboard to its power source. The reservoir should preferably be installed at the highest point of the cooling circuit (top 5 ¼ tray), although this is not absolutely necessary if all the other components are self-purging. Think about the airflow inside your chassis. In liquid-cooling environments, it is always better to draw fresh air from the outside through the radiator, as opposed to using the warm air from inside the computer. Make sure to dry-fit all components before making final connections and filling the water-cooling system. 2. TUBE ROUTING The tubing for the water-cooling system must be routed to form a complete loop that includes all elements of the system. When daisy-chaining components, the simplest and most natural route is usually the best. Always avoid sharp bends that would kink the tubing! The following table contains examples on how to establish connections between the different elements of a cooling circuit based on multiple possible configurations. These are guidelines only, and may change depending on the relative position of the components inside your chassis. Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 4 of 15

5 From a performance standpoint there is very little performance to be gained from strictly controlling the component sequence: the maximum difference in temperature between any two points of the liquid cooling circuit does not exceed 1ºC. Whenever possible, performance oriented users will typically want to route the radiator discharge(s) tube(s) to the inlet of the CPU cooler, since the fluid exiting the radiators is always the coolest. Devices: (1) CPU cooler + (1) Radiator + Pump-reservoir assembly Connect: Pump discharge to radiator inlet Radiator discharge to CPU cooler inlet CPU cooler discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! Alternatively, Connect Pump discharge to CPU cooler inlet CPU cooler discharge to radiator inlet Radiator discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! Devices (1) CPU cooler + (1) VGA cooler + (1) Radiator + Pump-reservoir assembly Connect: Pump discharge to VGA Cooler inlet VGA cooler discharge to radiator inlet Radiator discharge to CPU cooler inlet CPU cooler discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! Alternatively, Connect: Pump discharge to CPU cooler inlet CPU cooler discharge to VGA cooler inlet VGA cooler discharge to radiator inlet Radiator discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! Devices: (1) CPU cooler + (1) VGA Cooler + (1) chipset Cooler + (1) Radiator + Pump-reservoir assembly Connect: Pump discharge to chipset cooler inlet Chipset cooler discharge to VGA cooler inlet VGA cooler discharge to radiator inlet Radiator discharge to CPU cooler inlet CPU cooler discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! Alternatively, Connect: Pump discharge to CPU cooler inlet CPU cooler discharge to chipset cooler inlet Chipset cooler discharge to VGA cooler inlet VGA cooler discharge to radiator inlet Radiator discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! Devices: Dual CPU cooler and VGA cooler (SLI) configurations Connect: CPU coolers in series: CPU cooler (1) discharge to CPU cooler (2) inlet VGA coolers in series: VGA cooler (1) discharge to VGA cooler (2) inlet Devices: Dual Radiators: A second radiator can be added anywhere in the loop in series with the other components, for example Connect Pump discharge to radiator (1) inlet Radiator (1) discharge to VGA cooler inlet VGA Cooler discharge to chipset cooler inlet Chipset cooler discharge to radiator (2) inlet Radiator (2) discharge to CPU cooler inlet CPU cooler discharge to reservoir inlet Reservoir discharge to pump inlet MANDATORY! II. Installation of the cooling components Warning! Placement of the cooling components may vary depending on your chassis and motherboard configurations. A mock-up installation is thus necessary to estimate the length of the different sections of tubing that will be required between each component. The following is the recommended sequence of components installation. 1. Radiator and fan 2. Water-block(s) 3. Pump 4. Reservoir Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 5 of 15

6 1. MCR220 RADIATOR INSTALLATION Preamble: The MCR220 dual 120mm radiator ships with the fans and the Radbox chassis already pre-assembled to the radiator. It is assumed in effect that users will take advantage of our Radbox concept (external radiator installation) due to the benefits it provides and ease of installation. In such context, the following installation guide describes this type of installation. We also recognize that due to various considerations (cosmetics, space, or simply user preference) a number of users will wish to install the MR220 radiator internally. Because of the large size of the radiator, it is most likely that an internal installation will require extensive modifications in most computer cases. Because these modifications depend on the structure and dimensions of each individual chassis, we simply cannot provide precise installation instructions to this effect. Here are some general guidelines that advanced case-modders should take into consideration: Radiator installation, general considerations: For optimum performance, radiators require an unobstructed source of cool air. From a performance standpoint, the most effective solution is to draw cool air from the exterior. A second but equally important consideration is maintenance: air accumulates in any liquid cooling loop over time, and always tends to be trapped at the highest point of the loop. Swiftech radiators are self purging as long as they are oriented vertically, with the fittings positioned right-side-up. So, installing the radiator in it s intended orientation (shown below) is the most desirable solution: External Installation: An external mounting of the radiator is advantageous from both a performance and maintenance stand-points. This can be easily effectuated by means of the provided Radbox. The Radbox is affixed to the backside of the case and the tubing is routed through pre-existing or drilled holes in the case. This place the connections at the top of the radiator and will prevent the accumulation of air in the radiator. Because of tube-routing considerations, it is not always possible to install the radiator vertically right-side-up; installing the radiator upside down also works, but users are cautioned about the accumulation of air at the top of the radiator over time which will require periodic purging of the system. Internal installation: Mounting a dual 120mm radiator internally often results in placing the radiator horizontally at the top of the case, with the fittings looking down or at the bottom of the case, with the fittings looking up. Placing the radiator at the top of the case will allow air to accumulate over time and requires periodic purging maintenance. Placing the radiator at the bottom of the case will make the radiator self-purging, but it may also gather dust VERY quickly if adjacent to the floor. In many situations, mounting a dual 120mm radiator inside a case may also require extensive modifications for the air inlet and mounting of the radiator; it should be noted however that case manufacturer growing awareness for watercooling fosters the release of liquid-cooling ready solutions that will greatly facilitate the installation of this kit. There is no standard in this respect, and therefore no formula for installation; as a result users will simply need to exercise common sense and good judgment. Using the Radbox: exploded view Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 6 of 15

7 Installation Place the radiator assembly to the back panel of the computer in order to roughly estimate where it will fit best. You need to consider the following clearance issues: Exit cables and connectors from various PCI devices: the Radbox base plate can be moved in both vertical and horizontal directions to allow clearance for the cables. Opening the side panel once the Radbox is installed: the Radbox is supplied with various nylon spacers to separate the base plate from the surface of the back-panel and to provide clearance for opening of the side-panel. Note that a chassis with 80mm fan opening(s) is likely to provide a very good range of adjustments. Conversely, a chassis featuring a single 120mm fan opening the base-plate is a direct bolt-on, but offers no adjustments, which may or may not suit our installation for the purpose of positioning the radiator. In that case, it will be become necessary to drill (4) mounting holes of (~3.5mm) in diameter to install the base plate at the desired location. Securing the base plate at the desired location. Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 7 of 15

8 Once satisfied with the position, bolt down the Radbox back-plate with the provided nylon nuts. Routing of the tubes thru the chassis: Many of the current chassis offered on the market now come with pre-drilled holes to route the tubing thru the chassis. If your chassis does not have this feature, it will be necessary to drill the holes yourself. Since the OD of the tubing that comes with your kit is ¾, we recommend using a 1 bi-metal hole saw (shown below) to open up these holes. Once done, make sure to properly deburr the edges of the hole to prevent damage to the tubing. Once the two holes are cut, de-burr the edges, and optionally install grommets (not provided) Install your radiator assembly onto the back plate and fasten with the 4 provided short screws. Finally, you need to route the fan wires through the backpanel. This can be done easily with the provided PCI adapter plate featuring a hole and grommet for protection of the wire as shown below. Fan speed adapters: please note that your kit includes fan speed adapters that will allow you to tune the fan speed down if desired. 2 types of adapters are provided: 12 to 7 v, or 12 to 5v. The 12 to 7 volt adapters connect first to the fan connector, then to a motherboard 3 pin header; the 12 to 5v adapter connect first to the fan connectors, then to a 4 pin molex connector from the power supply. For full speed operations, simply connect the fans directly to your motherboard 3 pin connectors. Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 8 of 15

9 2. APOGEE XT WATERBLOCK INSTALLATION Please refer to the separate installation guide included inside of the waterblock box. Re-installing the motherboard Once the APOGEE waterblock securely fastened to the motherboard, go-ahead and install the motherboard into the chassis, following the instructions provided in your motherboard installation guide. 3. PUMP INSTALLATION General Use The MCP655-B pump is a magnetically driven centrifugal pump featuring a 12 V DC motor. It requires no maintenance when used with de-mineralized water and the appropriate anti-fungal additives. We recommend using 5% Swiftech s HydrX as an additive. The pump is designed to be connected to your computer power supply using the standard Molex 4 pin connectors. A second 3-pin connector (single blue wire) is an RPM sensor designed to be connected to the motherboard in lieu of the CPU fan connector and the motherboard to read the pump speed. The MCP655-B pump is neither submersible, nor self- priming. The inlet needs to be continuously supplied with fluid for the pump to operate properly. Physical installation Determine the best location for your pump by observing how the tubing will be routed to the rest of the circuit. Sharp bends in the tubing should always be avoided to prevent kinks, which will reduce or cmpletely prevent flow of the cooling fluid. Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 9 of 15

10 In general, we recommend installation of the pump at the bottom of the chassis. The base of the pump features a soft neoprene pad coated with strong adhesive material. Once the final location for the pump has been determined, simply peel-off the pad s protective paper, and press the pump against the chassis surface. The surface should be clean, and non greasy. Thru-bolts are also provided for permanent installation, and require drilling holes in the chassis. Pump operating precautions: The MCP655-B pump should never be run dry, even for a quick test. You should always prime the pump with fluid before you start operating it (see warranty note *). Use of coloring die or fluorescent additives containing particulate fillers will cause excessive wear to the pump s impeller bearing (see warranty note **). Note 1: Always make sure to directly connect the RESERVOIR DISCHARGE to the PUMP INLET. Permanent installation to the chassis, and exploded view Nominal voltage / Connector 12 V DC / Molex 4 pin Maximum pressure 50 PSI (3.5 BAR) Operating voltage range 8 to 24 VDC Maximum head 10 ft (3.1 m) Nominal current (@ 12 V) 2 amps Maximum discharge ~ 317 GPH (1200 LPH) Nominal power (@ 12 V) 24 W Temperature range 32 F to 140 F (0 C to 60 C) Motor type Brushless, microprocessor controlled Weight 1.4 LB (650 gr.) Impeller Housing material Noryl Connection size ½" barbs 4. MCRES-MICRO RESERVOIR INSTALLATION Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 10 of 15

11 Figure 1 Port Usage definition Upper side port: Inlet as shown in figure 1 is the return line from the system Lower side port: Outlet (to pump) shown in figure 1 should always be connected to the pump inlet (directly if possible to facilitate filling of the system) The fill-port located on top of the unit is used to fill it up with coolant, and sealed with a chrome plated brass plug. The alternate port is also sealed with a chrome plated brass plug, and can be used as: An alternate outlet providing a straight tube routing to a pump located underneath To feed a second pump To plug-in a temperature sensor A drain Installation The MCRES-MICRO can be installed in any suitable location meeting its form factor requirements. For filling purposes, it is preferable to install the MCRES-MICRO at the highest point of the liquid cooling loop. However, once filled and hermetically closed, the reservoir can be installed practically anywhere as long as it is kept upright as shown in figure 1. Also, to facilitate the filling and bleeding operations, you might want to wait until the circuit has been filled-up before you fasten the reservoir permanently to the chassis. Fastening the device to the case: two mounting methods can be used Various permanent mounts thru the reservoir ears or with the provided mounting hardware as shown page 3. Easy mount, with the provided Velcro strips. Please note that a permanent mount is recommended for a reliable fastening of the device over time. Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 11 of 15

12 MCRes Micro Bracketry installation and examples ITEM NO. PART NUMBER DESCRIPTION QTY 1 BCKT1 "L" bracket. 1 2 BCKT2 "U" bracket A x3-8-philips 6-32 x 3/8 Philips screw A X x 1 3/4" Philips screw A Nut w/teeth washer FW150X437X092 Rubber Washer 437X150X A041-WASHER zinc plated washer Note 1: rubber washer 6 should be inserted between either side of the reservoir ear and the U bracket Panel 6 DRILL ONE.150" (3.8MM) HOLE UPRIGHT MOUNT Reservoir ear 5 4 HANGING MOUNT BACK-PANEL MOUNT Panel Panel DRILL TWO 0.150" HOLES 2.00 " (50.8mm) APART Note 2: the 6-32 x 1 3/4 screw #4 & nut # 5 assembly is designed to protrude as little as possible in order to reduce overall clearance necessary for the Micro Res assembly. It is thus necessary to slightly push the nut in order to engage it on the screw thread. Preparing the coolant Your kit comes with a 2 Oz (60ml) bottle of Swiftech s specially formulated HydrX concentrated coolant. The product should be mixed with distilled water only. Simply empty the concentrated coolant into a 33 fl oz (1 liter) plastic bottle, and complete filling with distilled water. Your coolant is now ready. Note: a 5% mix might still allow some algae formation over prolonged usage if your system is continuously exposed to daylight (such as a clear acrylic case for example). Under such circumstances, we would suggest using a 10% mix. Use of alcohols (Alcohol Allyl, Amyl, Benzyl, Ethyl (Ethanol), Isopropyl, Methyl (Methanol), n-butyl) or antifreeze products containing the listed alcohols is prohibited as it will result in deterioration of the reservoir over-time, and will void your warranty. Resistance to Ethylene and Methylene glycol used in antifreeze products is excellent. Minimum Operating Level is situated at the Swiftech Logo (approximately ½ of the reservoir). The reservoir should not be operated below this level, which could result in degradation of the system cooling. Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 12 of 15

13 5. INSTALLING THE TUBING With one end of a tube connected to a startup component such as the water-block for example, roughly estimate the length that you will need to the next component, and cut the tube squarely with a pair of scissors. Work your way through the entire circuit in the same fashion, until you are satisfied with the tube routing. Always avoid sharp bends to prevent the tube from kinking. Connect all the components together, and secure the connections with the provided hose-clamps as shown below. ALWAYS MAKE SURE THAT THE CLAMPS ARE TIGHT, AS THIS IS ONE OF THE PRIMARY SOURCES FOR LEAKS. 6. COMPLETING THE INSTALLATION Re-installing your power-supply Prior to fill-up the circuit, you will need to re-install your power-supply in order to start-up the pump during the fill procedure. You must be able to start the PSU without it being connected to the motherboard. While the Internet contains numerous references on how to use a paper-clip to short-out pin 13 and 14 of the 20 pin ATX connector as shown below, we nonetheless recommend instead using a power-supply tester. A wide variety of these common devices are available on the Internet (Google key word: PSU tester ), and among Swiftech resellers ( etc.) Filling-up the circuit Simply pour the coolant that you prepared into the reservoir carefully to avoid spills, allowing the circuit to fill-up by simple gravity. Note: for the gravity to take effect the reservoir should be placed or held at the highest point of the cooling circuit. Once the reservoir is full, seal the fill port back with its cap in order to avoid any spills, and start-up the pump. The reservoir will quickly (within 1 second) empty itself. Immediately turn off the pump, top-off the fluid to the maximum level, and restart the pump. You need to repeat this operation 2 to 3 times, until the circuit is finally full of coolant. Then, allow the system to run 10 minutes uninterrupted to clear all the micro-bubbles and foam, and finally top-off the level one last time. Your liquid cooling circuit is now ready, and you may permanently install the reservoir. Allow the system to run for (3) hours and frequently inspect all your connections for possible leaks before you reconnect and re-install all your components (motherboard, hard drives, etc.) CONGRATULATIONS, YOUR INSTALLATION IS NOW COMPLETE! Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 13 of 15

14 Example of installation 7. TROUBLESHOOTING Air keeps circulating into the circuit, long after the pump has primed: o There is a significant pocket of air trapped into the circuit. In most cases this will be due to the fact that the radiator and or the water-block where installed upside down. Temporarily dismount the device and re-orient right side-up until all the air has escaped back into the circuit. o The fluid level is too low: top-off the reservoir to the appropriate level. o One of the components connections is loose, or improperly tightened: Inspect each connection for traces of moisture, and tighten all worm-drive clamps, and various connections in the circuit. The pump does not prime. It is likely that the circuit is not installed correctly. Please check that the reservoir discharge is duly connected to the pump inlet. Reminder: do not let the pump run dry. The Coolant is filled with debris of some sort: Despite our best efforts, such as lengthy ultrasonic cleaning of the radiator, and careful inspection and cleaning of all the parts we manufacture, it is always possible that debris or some sort may be contaminating your circuit. When this happens it will significantly affect the performance of the APOGEE water-block, which mini-jets can be easily obstructed due to their small size. The circuit should then be completely flushed (see draining procedure below), and the APOGEE water-block should be disassembled for inspection and cleaning. 8. DRAINING THE SYSTEM Open up the fill-cap from the MCRES-Micro Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 14 of 15

15 Then, you will need to disconnect a line from one of the lowermost components. Typically, this would be the pump. You need to procure a bucket large enough to receive approximately 1 liter of fluid, and place the bucket underneath the connection that you intend to break. Disconnect the line, and place both ends into the bucket, until all the liquid is drained from the system. 9. PERIODIC MAINTENANCE Every 6 months: dust off the radiator fins and fan. You can use a can of compressed air for example, available in most electronic supply stores. If you live in a very dusty area, you should perform this task at closer intervals. It is essential to maintain the optimum performance of your cooling system. Inspect the liquid level inside the reservoir, and refill if necessary (no refills are normally necessary for 18 months of continuous usage). Evaporation in this closed circuit is extremely limited, but still present due to some permeability in the vinyl lines. 10. OPTIONAL COMPONENTS Please visit our web site at on a regular basis, as we continuously release new products that could enhance the use of your H Apex Ultima liquid cooling kit! Thank you for trusting Swiftech for your computer-cooling needs! Rouchon Industries, Inc., dba Swiftech 151 West Victoria Street, Long Beach, CA Tel Fax E Mail: help@swiftech.com 15 of 15

These instructions are updated on a regular basis. Please visit our web site at

These instructions are updated on a regular basis. Please visit our web site at These instructions are updated on a regular basis. Please visit our web site at www.swiftech.com Rouchon Industries, Inc., dba Swiftech 3700 Industry Avenue, Suite 104, CA 90712 Tel. 562-595-8009 Fax 562-595-8769

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODEL: CFF-500 Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: May 10, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015 SCD SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER 21-11-1042 Issued March 2015 Copyright 2015, Galiso, Inc. 22 Ponderosa Ct., Montrose, CO 81401 (970) 249-0233 (800)

More information

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17) Installation Manual V-220 / V-320 Heater Kits Installation Instructions TK 56340-18-IM (Rev. 0, 06/17) Installation Manual V-220 / V-320 Heater Kits Installation Instructions TK 56340-18-IM (Rev. 0, 06/17)

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS VIKING 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 IMPORTANT - PLEASE READ AND FOLLOW Before beginning - please read these instructions

More information

P/N CC-100. Coolant Circulator. Operation manual

P/N CC-100. Coolant Circulator. Operation manual P/N 4411-0019 CC-100 Coolant Circulator Operation manual Manual Version 1 Revision B July 1, 1998 Table of Contents Chapter 1 Introduction... 5 Description...5 Specifications...5 Chapter 2 Warnings...

More information

BMW E36 Thermostat Removal And Coolant Flush

BMW E36 Thermostat Removal And Coolant Flush BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could

More information

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D. A-11978 HEATER KIT Figure 1 (General Layout and Parts I.D.) Read these instructions and identify all components. Please retain these instructions for future reference and parts ordering information. Refer

More information

Installation Instructions for. DairyFount Series Fountains

Installation Instructions for. DairyFount Series Fountains Installation Instructions for DairyFount Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains Installation Instructions for WaterMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J Transmission Cooling System J-45096 Operation Manual TRANSFLOW Transmission Cooling System Service Tool J-45096 1 Safety Precautions WARNING: TO PREVENT PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT: ALLOW

More information

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES PumpAgents.com - Click here for Pricing/Ordering Model 36950-2 Series ELECTRIC WATER SYSTEM PUMP Automatic Multi-Outlet FEATURES Self-Priming Diaphragm Design Allows Dry Running Built-in Discharge Check

More information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE. Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower Installation, Care and Use of Your Lynx Beverage Tower Kits MOM FRIENDLY. DAD READY. L24TWS Beverage Tower Kit Components L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower Introduction:

More information

STEAM WALLPAPER STRIPPER MODEL HTW5

STEAM WALLPAPER STRIPPER MODEL HTW5 STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,

More information

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains Installation Instructions for WaterMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw Exceeding Military Standards without the Cost Electric Radiator A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw Description An engine s belt driven or direct driven

More information

DURANGO 12V Heater HF

DURANGO 12V Heater HF DURANGO 12V Heater HF-100012 1 Product description 2 Operating principle 3 Mounting recommendations 4 Troubleshooting 3 Safety instructions Page 1 of 5 1 Product description The DURANGO heater consists

More information

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses SAAB 99 Series 1981 1984 H Type Engine Installation Guide Silicone Cooling System Hoses Classic Silicone Hoses http://www.classicsiliconehoses.com/ Disclaimer This document is for reference purposes only.

More information

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation

More information

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions OPERATOR S MANUAL & PARTS LIST HYBRID DRYER PDH - PDH Series Save These Instructions Tacony, Inc., All rights reserved WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING

More information

CHILLERS. Operator s & Installation Manual

CHILLERS. Operator s & Installation Manual CHILLERS MODELS: CH750, CH751 & CH951 Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: May 5, 2010 Revision: D Visit the IMI Cornelius web site at

More information

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391 Harbor Breeze Harb or Breeze ITEM #0915543 BUILDER S SERIES CEILING FAN MODEL #41391 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 18 ATTACH YOUR RECEIPT HERE Purchase

More information

Model 6021 Electrically Heated Rain and Snow Gauge

Model 6021 Electrically Heated Rain and Snow Gauge Model 6021 Electrically Heated Rain and Snow Gauge User s Manual 1165 National Drive Sacramento, California 95834 USA www.allweatherinc.com Table of Contents General Information... 1 Introduction... 1

More information

A HEATER KIT With Diesel Engine Connection Fittings

A HEATER KIT With Diesel Engine Connection Fittings A-12142 HEATER KIT With Diesel Engine Connection Fittings Figure 1 (General Layout and Parts I.D.) Page 1 of 6 Read these instructions and identify all components. Please retain these instructions for

More information

Engine Cooling Pulsator

Engine Cooling Pulsator Engine Cooling Pulsator ENGINE COOLING SYSTEM FLUSHER U.S. Patent No. 5615695 Perfect for Blasting Clean Heater Cores, Radiators, Heads, Intakes, & Blocks. WARNING: THIS IS A VERY POWERFUL BLASTING DEVICE

More information

AUC Cell Washer. User Manual

AUC Cell Washer. User Manual AUC Cell Washer User Manual WARRANTY Spin Analytical Inc., warrants this product to be defect free in both material and workmanship for 90 days from the date of shipment. Labor services are guaranteed

More information

POWER PACK SERVICE MANUAL

POWER PACK SERVICE MANUAL POWER PACK SERVICE MANUAL MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

CL & CLG Clamp Mount Mixers

CL & CLG Clamp Mount Mixers CL & CLG Clamp Mount Mixers CL / CLG Series OWNERS MANUAL Warranty Our products are guaranteed against defective materials and workmanship, we will repair or replace such items as may prove defective at

More information

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual Owner s Manual Model: Can Am Commander Heater for BRP Commander Caution: Before using this product, read this manual and follow all safety instructions. Safety Instructions Kit Contents Tool Requirement

More information

BlueHeat AirTop 2000 Heater

BlueHeat AirTop 2000 Heater BlueHeat AirTop 000 Heater Air Heater Installation Manual Ford E-Series 6.0L Diesel Beginning Model Year: 006 Special instructions for these models Part locations may differ slightly dependent on the vehicle

More information

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050 INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050 1 2 TECHNICAL DATA Recommended Water Pressure 35-75PSI Max. Water Pressure 145 PSI Recommended

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

Model Series Series

Model Series Series PumpAgents.com - Click here for Pricing/Ordering Model 36800-Series 36900-Series ELECTRIC WATER SYSTEM PUMPS Automatic Multi-Outlet FEATURES Self-Priming Diaphragm Design Allows Dry Running Built-in Discharge

More information

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. all the comforts of home FEATURES SPECIFICATIONS INSTALLATION The Marine Throne "all the comforts of home" Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual

More information

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. OPERATOR S MANUAL & PARTS LIST HYBRID DRYER PDH - PDH Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. Tacony, Inc., All rights reserved Save These

More information

WA A Aqua Sub Bottom-load Water Cooler

WA A Aqua Sub Bottom-load Water Cooler WA1-02-21A Aqua Sub Bottom-load Water Cooler 4002638 Thank you for choosing a Soleus Air Water Cooler. This owner s manual will provide you with valuable information necessary for the proper care and maintenance

More information

EXC-450 User s Manual

EXC-450 User s Manual Superior Liquid Cooling Systems www.koolance.com EXC-450 User s Manual English v1.0 ISO 9001 Printed in Korea A newer version of this User Manual may exist. Please be sure to check our support page for

More information

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL S-SCORT II Model 15006 SSCOR, INC. 11064 Randall Street Sun Valley, CA 91352 USA Telephone +1-818-504-4054 800-434-5211 Fax +1-818-504-6032 www.sscor.com Email:

More information

INSTALLATION INSTRUCTIONS WARRANTY

INSTALLATION INSTRUCTIONS WARRANTY QT FLOW CENTER INSTALLATION INSTRUCTIONS Fig. 1. Low Head Pump Center Flow Chart Fig. 2. High Head Pump Center Flow Chart NOTE: Read the entire instruction manual before starting the installation. WARRANTY

More information

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION PumpAgents.com - Click here for Pricing/Ordering Model 37045-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual function

More information

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. 6. Cooling System XCITING 400i Cooling System This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. Coolant... 6-3~6-11 Radiator... 6-12~6-23 Thermostat...

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES INSTALLATION GUIDE KT-CDR2 & KT-CDR3 Including Mounting & Sealing of Housing & Electrical Details For COOLDOME ENCLOSURE SERIES KT-CDR2 For D2 COOLDOME KT-CDR3 For D3 COOLDOME PRODUCT INSTALLATION PRECAUTIONS

More information

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482

More information

WARMING AND MERCHANDISING CABINET

WARMING AND MERCHANDISING CABINET WARMING AND MERCHANDISING CABINET Above red graphics now replace green graphics shown in photo. MODEL 695 (Single door unit shown) MODEL 695-S (Single door unit shown) Snack foods have to be hot and moist

More information

Thermalright. Macho 120 Rev.A

Thermalright. Macho 120 Rev.A Thermalright Macho 20 Rev.A Macho 20 Rev.A Assembly package 7 5 Chill Factor 2g 2 8 Macho 20 Rev.A Intel 775/50/55/56/66 Exploded View Important! Before proceeding with installation, please check for

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump

More information

CH750, CH751 & CH951 CHILLERS

CH750, CH751 & CH951 CHILLERS CH750, CH751 & CH951 CHILLERS Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com

More information

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date ITEM #0807426 ARMITAGE CEILING FAN MODEL #CC52WW5L Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 17 ATTACH YOUR RECEIPT HERE Purchase Date 4009654 Questions, problems,

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch SW-38 Solar Panel(s) Hot Water Cold Water PV panel Glycol RV Water Heater WITH built in Heat Exchanger Water Ports ` Glycol Fill Valve 1 Pump Solar Powered Expansion Tank Glycol

More information

EXT-440 User s Manual

EXT-440 User s Manual Superior Liquid Cooling Systems www.koolance.com EXT-440 User s Manual English v1.0 ISO 9001 Printed in Korea Protected by U.S. Patents 6,313,990; 6,664,627; 7,167,366; 7,295,436 Other Technology Pending

More information

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 Owner s Manual Keep with machine for reference GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895- 2141 www.cmadishmachines.com

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

Alphacool Eisbaer LT

Alphacool Eisbaer LT Alphacool Eisbaer LT What is it? The Alphacool Eisbaer LT is an expandable and compact water cooling system for CPUs. The quickconnectors make it expandable and compatible with all other Eisbaer Ready

More information

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE Ambassador 20 Automatic Carpet Scrubber Model: C8420-115 C8420-240 OPERATION SERVICE PARTS CARE This manual is furnished with each new Minuteman Ambassador 20. This provides the necessary operating and

More information

BC BRONCOS AIR CONDITIONING UNIT

BC BRONCOS AIR CONDITIONING UNIT BC BRONCOS AIR CONDITIONING UNIT CAUTION If you are not familiar with the principals of air conditioning, have an authorized air conditioning technician evacuate and charge the system. Serious damage to

More information

Oahu Showerspa Model #1035 Owner's Manual

Oahu Showerspa Model #1035 Owner's Manual O A H U Oahu Showerspa Model #1035 Owner's Manual Oahu ShowerSpa Model #1034 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation goes smoothly and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER DBRTGK72SS-GRILLE KIT (FOR designer SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662)

More information

CalMag Filter Installation Instructions

CalMag Filter Installation Instructions Calming troubled waters CalMag Filter Installation Instructions Please note: This filter is unique and does not have or need a messy top mounted air bleed valve. Air is channelled via a snorkel arrangement

More information

MTC-Series Manual Trash Compactors Instruction Manual

MTC-Series Manual Trash Compactors Instruction Manual Vestil Manufacturing Co. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 Website: www.vestilmfg.com e-mail: info@vestil.com

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08 EFFECTIVE: MAY, 2014 American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 The American Dish Service part numbers contained in this

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Please read carefully and retain for future reference. CONTENTS 1. Important Information 2. Included Parts 3. Filter Head Assembly Instructions 4. Installation Instructions 4.1. Auxiliary Tap Connection

More information

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X Installation Truck Refrigeration & Commissioning Manual: INSTALLATION AND COMMISSIONING MANUAL for Neos 100S Integra 20X, 30S, 35X, 40X, 50X Direct Drive Refrigeration Units 2017 Carrier Corporation Printed

More information

ELSTON 52 CEILING FAN

ELSTON 52 CEILING FAN ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -

More information

Cool IR. Model C104 - Cooling System. Instruction Manual

Cool IR. Model C104 - Cooling System. Instruction Manual Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...

More information

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5 Section V COOLING SYSTEM CONTENTS Fluid Fan Drive (Silent Flite) 3 Water Pump 4 Radiator 5 Water Temperature Gauge 6 Thermostat 7 Radiator Pressure Cap 7 Service Diagnosis 7 DATA AND SPECIFICATIONS COOLING

More information

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 Owner s Manual Keep with machine for reference PKC24 INSTALLATION & OPERATION REV.11.09 Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 800-558- 5592 FAX 414-353- 7069 perlick.com TABLE OF

More information

52 CEILING FAN. Owner s Manual Models #50336, 50337

52 CEILING FAN. Owner s Manual Models #50336, 50337 52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.

More information

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM 148 OLD CONCORD TURNPIKE BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM CONDENSING

More information

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

CABS/BLADES/ SPREADERS/ACCESSORIES

CABS/BLADES/ SPREADERS/ACCESSORIES JOHN DEERE 3000 SERIES (4200/4300/4400) (4210/4310/4410) (3120/3320/3520/3720) JOHN DEERE 4000 SERIES (4500/4600/4700) (4510/4610/4710) (4120/4320/4520/4720) OPTIONAL AUXILIARY HEATER INSTALLATION (p/n

More information

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg. The Extraordinaire Orbital Fan WARNING: Support Directly From Building Structure Net Weight 14.5 lbs. or 6.59 kg. Model No. OF110** OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Important Safety Instructions

More information

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Troubleshooting the MPH 24FP Series Pedestal Hydrant MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F CFF-500 CHILLER Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com for

More information

Model K 5800 G Part No

Model K 5800 G Part No K5800G Manual 11/30/01 5:02 PM Page 1 Model K 5800 G Part No. 1.194-103.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2

More information

OWNER S MANUAL ADVENTURER SERIES. Electric Grill A10-603E

OWNER S MANUAL ADVENTURER SERIES. Electric Grill A10-603E OWNER S MANUAL ADVENTURER SERIES Electric Grill A10-603E For questions regarding performance, assembly, operation, parts, or returns, contact the experts at MAGMA by calling (562) 627-0500 7:00 a.m. -

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

Heater with Air Conditioning. E-Series Ford Aeromaster

Heater with Air Conditioning. E-Series Ford Aeromaster Service Guide Heater with Air Conditioning E-Series Ford Aeromaster Contents Blower Motor...2 Plenum Removal...3 Control Module...6 Servo Motors...8 Coolant Valve and Servo Motor...8 Evaporator Recirculation

More information

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL Ideal for ponic System Reservoirs 1/2 HP 53-317 GALLONS (200 TO 1200L) AACH50 INSTRUCTION MANUAL Before operating this appliance, please read the instruction manual thoroughly and keep on file for future

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS 4400 Series Power Paks MODEL NOS. 4400 Series 4404 4420 4410 4404W 4414 4410W 4414-230 4414W c IMPORTANT INFORMATION To register your product, visit our web site

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.75 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

17 U.S. gallon portable low profile drain with electric pump

17 U.S. gallon portable low profile drain with electric pump Assembly and operation instructions 17 U.S. gallon portable low profile drain with electric pump Model 3669 Date of issue February 2018 Form number 404513 Version 2 Contents Safety...........................

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.35 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION OPERATION INSTALLATION PARTS MANUAL www.fostoriaindustries.com Made in U.S.A. ELECTRIC PORTABLE HEATER FES-1024-1CA 08860010 YES-1024-1CA 08861510 FES-1520-3A 08860110 YES-1520-3A 08860810 FES-1524-1A

More information

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find

More information

Kawasaki Teryx Firestorm Heater Kit Instructions.

Kawasaki Teryx Firestorm Heater Kit Instructions. Please read all instructions before beginning installation. When working on cooling systems always allow vehicles to cool to avoid being burned or scalded by hot coolant. Always disconnect vehicle s negative

More information

60 Liter Infinity Storage Reservoir

60 Liter Infinity Storage Reservoir BARNSTEAD THERMOLYNE CORPORATION 60 Liter Infinity Storage Reservoir OPERATION MANUAL AND PARTS LIST Series 902 Model D9021 LT902X1 7/30/97 Serial Number 1 Table of Contents Safety Information... 3 Warnings...

More information

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL) INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL) Publication No. 01553 Revision 8 Printed in Canada 1.1 INTRODUCTION This manual

More information

Operator s Manual. Stripping Solution Applicator

Operator s Manual. Stripping Solution Applicator Operator s Manual Stripping Solution Applicator Record this Important Information Date of Purchase Purchased From Address City State Zip Phone Contact Serial Number Emergency Contacts Medical Emergency

More information