Catalog RoofPak Singlezone, Heating and Cooling Systems with Evaporative Condensers

Size: px
Start display at page:

Download "Catalog RoofPak Singlezone, Heating and Cooling Systems with Evaporative Condensers"

Transcription

1 Catalog RoofPak Singlezone, Heating and Cooling Systems with Evaporative Condensers Models: RDE/RPE Tons RDE SWSI Airfoil (Plenum); SAF Draw-Through Cooling Coil; Filters; Steam or Hot Water Heat RPE DWDI Airfoil; SAF Blow-Through or Draw-Through Cooling Coil; Filters; Electric, Gas, Steam or Hot Water Heat

2 Table of Contents Introduction A New Standard in Rooftop Systems with Evaporative Condensers...3 Agency Listed...3 Nomenclature....3 Features and Options Energy Savings Evaporative Condenser Energy Savings...6 Features Refrigeration Circuit...8 Evaporative Condenser...8 Walk In Service Compartment...9 Cabinet Air Handling Section...10 Electrical and Controls...10 Factory Installed and Wired Options Condensing Section Air Handling Section...11 Intelligent Equipment...12 Daikin MictroTech III Rooftop Remote User Interface Electrical and Controls...13 Multiple Unit Applications...13 Field-Installed Roof Curbs...13 Optional Water Treatment...14 Application Considerations General...17 Location and Curb/Rail Support Filters...17 Acoustics...18 Economizer, Return Fan and Exhaust Fan Application...19 Variable Air Volume (VAV) MicroTech III Control...20 Unit Operating Range...21 Fan Operating Range...21 Indoor Fan and Motor Heat, Blow-Through vs. Draw-Through Cooling Table of Contents Recommended Clearances Service Clearance...23 Cooling Coil, Heat, and Supply Fan Service Clearance Overhead Clearance...23 Ventilation Clearance...24 Control and Power Wiring...25 Altitude Adjustments...25 Furnace Performance...26 Freezing Concerns Spray System Hot Water and Steam Coils...26 Water Treatment...26 Condenser Water Connections...27 Selection Instructions...28 Physical Data Cooling Capacity Data Heating Capacity Data Gas Piping Schematic Component Pressure Drops Fan Performance Data Return Fans & Exhaust Fans...44 DWDI Supply Fans...45 SWSI Plenum Supply Fans Dimensional Data Section Options and Locations...48 Typical Dimensions...51 Electrical Knockout Locations...53 Piping Entrance Locations...54 Roof Curbs Electrical Data Supply Power Wiring Unit Weights Fan Motor Weights...63 Roof Curb Weights...63 Engineering Guide Specification CAT ROOFPAK PACKAGED SYSTEMS 2

3 Introduction A New Standard in Rooftop Systems with Evaporative Condensers Introduction 76 through 150 tons Full factory operation test 100% make-up air, dehumidification, VAV or CV operation Modular construction and customized application flexibility Multiple fan, coil, filter and heat selections. High efficiency compressor and coil combinations Factory integrated and commissioned MicroTech III advanced DDC control system Daikin s Open Choices feature provides building automation system integration using BACnet MS/TP, BACnet IP, BACnet Ethernet, or LonTalk communication protocol options Durable, double-wall construction with access doors on both sides of each section Heavy-duty evaporative condenser designed for easy maintenance with a walk-in service compartment Blow-Through configuration for high sensible cooling and quieter operation Draw-Through configuration for high latent cooling or high humidity applications Agency Listed MEA N Manufactured in an ISO-Certified Facility Nomenclature R P E C S E RoofPak Unit Configuration P = Blow-Through Cooling D = Draw-Through Cooling Heat Medium A = Natural Gas E = Electric S = Steam W = Hot Water Y = None (Cooling Only) Evaporative Condensers Nominal Capacity (Tons) RPE, RDE: 076, 089, 100, 110, 130, 140, 150 Cooling Coil Size S = Standard (Low Airflow) L = Large (High Airflow) Design Vintage 3 CAT ROOFPAK PACKAGED SYSTEMS

4 Features and Options Features and Options MicroTech III Control System Factory-installed and tested to minimize costly field commissioning Open Choice feature provides building automation system integration using BACnet MS/TP, BACnet IP, BACnet Ethernet, or LonTalk communication protocol options State-of-the-art keypad interface allows easy adjustment of Direct Digital Control functions, bi-directional communications, stand-alone or network operation* Optionally: add the Intelligent Equipment control solution, which provides real-time data streams for benchmarking performance, monitoring system operations and implementing remote diagnostics and control 2 Airfoil Fans More energy efficient and quieter than forward curved fans. Double width, double inlet (DWDI) or single width, single inlet (SWSI) plenum fans 3 Durable Construction Pre-painted exterior cabinet panels pass 750 hour ASTM B117 Salt Spray Test for durability Heavy-duty R-6.5 insulation minimizes heat loss for reduced energy costs Double-wall construction protects insulation and provides a wipe clean surface to inhibit microbial growth Stainless steel, sloped drain pans eliminate standing water and provide long service life Full unit base rail with heavy-duty lifting lugs provide single piece rigging of units up to 150 tons 4 SuperMod High Turndown Gas Burner Full 20:1 turndown and multiple sizes enable precise temperature control at reduced design, installation, and life-cycle costs Maintain comfortable tenant environment in VAV, 100% make-up air, and dehumidification applications 5 Hinged Access Doors On both sides of every section for easy access to all components. Single lever latch and door holders provide easy entry and support routine maintenance. Double-wall construction protects insulation during maintenance. 6 Blank Sections Available throughout the unit to factory-mount air blenders, carbon or charcoal filters, sound attenuators, humidifiers, or other specialty equipment. Allow customization for maximum system performance and efficiency. 7 Walk-in Service Compartment Ventilation fan with a manual shutter allows conditioned air into the service compartment for comfortable servicing in hot weather Lights, electrical outlet, main control panel, spray pump, water connections, and optional water treatment system Drain pan under the water piping and a raised floor grate in the pan keeps the walking area dry. Single field connections to makeup water and drain lines CAT ROOFPAK PACKAGED SYSTEMS 4

5 Features and Options Modular Flexibility Allows you to specify the unit you want, optimized for high energy efficiency, good IAQ, and quiet operation 100% make-up air, dehumidification, CV, and VAV operation Blow-Through cooling coil configuration (shown) provides higher sensible cooling, a quiet tenant environment, and energy savings Draw-through cooling coil configuration provides higher latent cooling for make-up air systems or systems with high humidity loads Multiple filter, fan, coil, and heating options and sizes to match system requirements. Extended face area filters and coils reduce system pressure drops and improve efficiency Multiple high efficiency compressor and coil combinations match 9 Return or Exhaust Fans Return fans can provide better building pressure and ventilation control as return duct pressure drop increases. Exhaust fans can save energy as return duct pressure drop requirements decrease. 10 Factory-Mounted Variable Frequency Drives Control fan motor speed for lower fan operating costs and sound levels in VAV systems. 11 Economizer Outside air enters from both sides, improving mixing for better temperature control. DesignFlow Precision Outdoor Air Measurement and Control System accurately measures and maintains outdoor air quantity. Patented UltraSeal low leak dampers minimize air leakage, reducing energy costs. Generous face area intakes/ outlets and control dampers reduce system pressure drops, improving efficiency. 12 Evaporative Condensing Section Open design allows easy access to compressors and refrigerant piping Unique rail support system allows the roof deck and insulation to help block compressor noise from entering the building Condenser tube bundles. Replaceable, slide out, sectional, sloped stainless steel sump. Heaviest piece weighs less than 175 pounds Entire spray chamber is enclosed in stainless steel Replaceable mist eliminators Replaceable air inlet screens Vertical discharge propeller condenser fans with service guards reduce noise PVC spray system with spray pump, water treatment connections and float control automatically maintains acceptable water levels 5 CAT ROOFPAK PACKAGED SYSTEMS

6 Energy Savings Evaporative Condenser Energy Savings Energy Savings Air cooled condensers can only reject heat to the ambient dry bulb as the condenser air passes over the condenser surface. Typical design dry bulb temperature is often considered to be 95 F. However, actual rooftop dry bulb conditions are usually much greater due to solar heat on a dark roof. See Figure 1. Evaporative condensers use a cooling spray of water that evaporates and cools the condenser air down toward the typical ambient wet bulb temperature of 75 F. SeeFigure 2. Evaporative condensers, therefore, reject heat to colder temperatures and operate at lower condensing temperatures. Therefore less compressor work and energy are required. This allows compressors in an evaporative condensing unit to operate at lower condensing temperatures and consume 25 40% less electricity than comparable air cooled units, especially at design conditions. Refer to Table 1. Figure 1: Air-Cooled Condenser Figure 2: Evaporative Condenser Table 1: Air-Cooled vs. Evaporative-Cooled Condensers Design Conditions ARI Design Conditions Ambient Temperature Condensing Unit kw per ton Condensing Temperatures Air Cooled 95 /75 F F Evaporative Cooled 95/75 F F Desert Design Conditions Air Cooled 110 /72 F F Evaporative Cooled 110 /72 F F Rooftops with Evaporative Condensers Save Money 1. Savings in Electrical Consumption Costs Both consumption and demand usually drive the electrical costs for large, non-residential customers. Electrical consumption is the total energy consumed and is usually measured in kw Hours. Several factors influence consumption, including unit efficiency, operating hours, and load profile. Daikin s Energy Analyzer computer program is the ideal tool for estimating energy consumption for a given building. 2. Savings in Electrical Demand Costs Electrical demand is the peak energy consumed in a billing cycle and is usually measured in kw. Demand costs associated with air-cooled and evaporative-cooled rooftops are relatively easy to compare. a. The 25 40% reduction in peak design condensing unit kw translates into a 25 40% savings in condensing unit demand costs. Based on utility rate structures, this can be a substantial savings. b. In addition, Daikin offers airfoil supply and return fans that reduce design bhp and air handler demand costs by up to 20%. 3. Savings in Installation Cost Rooftop ampacity and electrical service costs are proportional to design kw. A 25 40% reduction in condensing unit design kw translates into smaller and less expensive wires, disconnects and transformers that feed the rooftop units. Daikin s airfoil supply and return fans often save one or two motor sizes and further reduce the required electrical service. Typical Savings vs. Air-Cooled Rooftop Systems To illustrate the savings generated by evaporative condensing, consider a two-story shopping mall using several 125-ton VAV rooftop units and occupied 365 days a year. Assume external static pressures of 2.5" for each supply duct and 0.5" for return ducts. Table 2 through Table 4 show the Daikin RPE evaporative condenser rooftop if this mall is located in the Los Angeles, New York and Las Vegas. CAT ROOFPAK PACKAGED SYSTEMS 6

7 Energy Savings Table 2: Comparison of Evaporative and Air-Cooled Condensing for the Los Angeles Area Mall Figure 3: Comparable Energy Performance to Water- Cooled Chillers Conditions Air-Cooled Daikin RPE Design Ambient Dry Bulb/Wet Bulb 95 F/72 F 95 F/72 F Electrical Consumption Rate (per kw Hour) $0.15 $0.15 Electrical Demand Rate (per kw) $24 $24 Condensing Unit Efficiency (kw/ton) Electrical Cost $30,200 $22,100 Percent Savings 27% All shopping mall energy analysis and comparison charts provided in this document have been generated using Daikin Energy Analyzer software. Table 3: Comparison of Evaporative and Air-Cooled Condensing for the New York Area Mall Conditions Air-Cooled Daikin RPE Design Ambient Dry Bulb/Wet Bulb 95 F/75 F 95 F/75 F Electrical Consumption Rate (per kw Hour) $0.11 $0.11 Electrical Demand Rate (per kw) $18 $18 Condensing Unit Efficiency (kw/ton) Electrical Cost $17,860 $12,375 Percent Savings 31% All shopping mall energy analysis and comparison charts provided in this document have been generated using Daikin Energy Analyzer software. Table 4: Comparison of Evaporative and Air-Cooled Condensing for the Las Vegas Area Conditions Air-Cooled Daikin RPE Design Ambient Dry Bulb/Wet Bulb 110 F/72 F 110 F/72 F Electrical Consumption Rate (per kw Hour) $0.07 $0.07 Electrical Demand Rate (per kw) $8 $8 Condensing Unit Efficiency (kw/ton) Electrical Cost $19,042 $11,351 Percent Savings 40% All shopping mall energy analysis and comparison charts provided in this document have been generated using Daikin Energy Analyzer software. Daikin Energy Analyzer Software Program Daikin Energy Analyzer is the perfect tool for quantifying the savings that can be generated by evaporative condensing. Energy Analyzer software can model energy consumption for almost any type of building based on local climate and utility costs. Using Energy Analyzer to Quantify Savings Go To The Primary System Screen (Figure 4) 1. Click On The Condensing Unit 2. Click On Air Cooled or Evap Cooled 3. Check The Defaults For access to Daikin Energy Analyzer Software, contact your local Daikin representative for a copy. To locate your Daikin representative, visit DaikinApplied.com or call (800) Figure 4: Energy Analyzer - Primary System Screen RPE Energy Costs are Competitive Using the 0.85 kw/ton condensing unit efficiency from the previous example, Figure 3 shows a comparison of a Daikin RPE evaporative condenser rooftop system with a 0.55 kw/ ton water-cooled chiller system. In this case, we assumed that the chiller system would have constant flow pumps and that it unloads to 0.46 kw/ton. As shown in Figure 3, the energy performance of the two systems is very comparable, with the RPE offering a significant part load advantage and the chiller offering a small full load advantage. Given that most air-conditioning systems operate at 60% load or less over the great majority of a typical year, the Daikin RPE may be the best energy savings investment. 7 CAT ROOFPAK PACKAGED SYSTEMS

8 Features Daikin RPE and RDE units contain the same air handler construction and controls as Daikin RPS and RDT applied rooftop units. For more detail, refer to RPS Catalog 214 and RDT Catalog 217. For a copy of these catalogs, contact your local Daikin representative or visit DaikinApplied.com. Refrigeration Circuit Open condenser design allows easy service access to compressors and refrigerant piping Multiple high efficiency Copeland Discus compressors mounted on isolators with crankcase heaters, positive displacement oil pump, low oil pressure protection control, 3-leg internal motor protection and cylinder unloaders for up to 8 steps of capacity control Dual refrigerant circuits include manual shut off valves on the suction, discharge and liquid lines, accessible sight glass, filter drier and solenoid valves (expansion valves are included in the air handler section). The controls include high and low refrigerant pressure protection control switches, manual control switch, and manual pump down switch Compressors are allowed to operate down to 45 F ambient, where economizer free cooling operation takes over Evaporative Condenser Unique rail support system allows the roof deck and insulation to help block compressor noise from entering the building Condenser tube bundles are constructed of corrosionresistant copper tubes, stainless steel casing, and polymer tube sheets The sloped, stainless steel sump is divided into multiple sections that slide out for easy replacement. The heaviest section weighs less than 174 pounds The entire spray chamber is constructed of corrosionresistant stainless steel Replaceable mist eliminators between the tube bundle and condenser fans minimize water consumption Replaceable air inlet screens keep sunlight out of the sump and help prevent microbial growth Direct drive condenser fans eliminate the service expense associated with belts and sheaves Vertical discharge, propeller condenser fans with service guards reduce horizontal-radiated noise 3-phase, severe duty, totally enclosed condenser fan motors with current sensing overload protection and permanently lubricated bearings support extended product life PVC spray system includes spray pump, water treatment connections and float control that automatically maintains acceptable water levels. Replaceable, clog resistant nozzles spray water across a 150 arc and completely wet the coil surface for improved performance. Single field connections to make-up water and drain lines can reduce installed cost Features Figure 5: Standard RPE and RDE Spray System Optional Cyclone Separator Optional Water Treatment System Hand Valve See Figure 15 on page 16 for Water Treatment Enhancements NOTE: The cyclone separator is on a side stream. A hand valve controls water flow. The hand valve should be opened until the inlet pressure to the separator is about psi as determined by the factory-installed gauge. This will yield about gpm of blowdown whenever the blowdown solenoid opens. Hose Bib with Manual Shut Off Valve Automatic Float Controlled Intake Valve Drain Optional Bleed-Off Solenoid Valve Spray Intake Water Sump Removable Screen Pump CAT ROOFPAK PACKAGED SYSTEMS 8

9 Features Figure 6: Corrosion Resistant Stainless Steel Fan Decks with Severe Duty Motors and Corrosion-Resistant Fans PVC Spray Tubes Stainless Steel Spray Enclosure Figure 7: Easy Service Access Stainless Steel Sump Polymer Tube Sheets Copper Tube Bundles Walk In Service Compartment All routine refrigerant service can be performed inside the walk-in service compartment away from compressor noise and outdoor conditions Contains marine lights, electrical outlet, main control panel, spray pump, water connections, and optional water treatment system A thermostat-controlled ventilation fan turns on at 75 F and a manual shutter draws conditioned air into the service compartment for comfort. These features provide more comfort for service even in hot weather A hose bib is provided as standard in the make up water line to aid in condenser cleaning A drain pan under the water piping and a raised floor grate in the pan help keep the walking area dry Optional unit heater for cold climate use No compressor noise is generated in the work area Sight glass, filter driers, solenoid valves and charging valves are in the service compartment Figure 8: Walk-In Service Compartment Marine Lights Exhaust Fan Access Doors on Both Sides Walk In Service Compartment Replaceable Sump Easy Compressor Access Replaceable Nozzles with 150 Spray Arc Main Control Panel Charging, Suction, Discharge & Liquid Schrader Connections Optional Unit Heater Hot Gas Bypass Valves Solenoid, Sight Glass & Filter Drier Raised Floor Grate and Drain Pan Space for Water Treatment 9 CAT ROOFPAK PACKAGED SYSTEMS

10 Features Cabinet Weather resistant skin is made of pre-painted, galvanized steel that successfully withstands a 750 hour salt spray test. The service compartment walls are double wall with R6.5 insulation sandwiched between the outer skin and inner liner. The air handler cabinet is also available with double-wall construction with R6.5 insulation Full-sized, double-wall, hinged access doors are provided on each side of the section, complete with a single lever latch Heavy gauge galvanized steel base with a formed recess sits on the gasketed curb and provides a weather-tight seal. The base also includes strategically placed lifting brackets to allow balanced cable or chain hook lifting Air Handling Section Factory piped, charged and tested refrigeration system comes complete with an aluminum fin, copper tube, DX coil with expansion valves and distributors. Each distributor tube is wrapped in plastic to help prevent refrigerant leaks DX coils feature interlaced circuiting to keep the entire coil face active during all capacity steps and eliminate the air bypass associated with face split coil designs. An intermediate drain pan collects condensate from the top half of the coil. Drain tubes run from the intermediate drain pan to the sloped, galvanized [optional stainless] steel drain pan High efficiency airfoil supply fans require less bhp and generate less noise than forward curved fans at the medium static pressures typical of large VAV units. Fans are available in both DWDI (housed) and SWSI (plenum) fan arrangements. For more information, refer to page 19 Insulated supply and return air plenums with bottom [optional horizontal] openings reduce ducted noise levels. A double wall option is available with perforated liners in these sections Figure 9: Airfoil Fans Electrical and Controls Single source power with optional, non-fused disconnect switch with control panel door interlock Individual short circuit protection for each compressor, supply fan and return fan motor. Condenser fan and exhaust fan motors are also provided with short circuit protection All control panel wiring is labeled per the wiring diagram and all volt wiring is housed in conduit or metal raceways Daikin s Open Choices feature provides building automation system integration using BACnet MS/TP, BACnet IP, BACnet Ethernet, or LonTalk communication protocol options. This allows any building automation system (BAS) to communicate with MicroTech III over an industry standard network and obtain access to the operating status, all set points, and alarms LONMARK certified discharge air control (DAC) or space comfort control (SCC) communication options BACnet compliant communication options MicroTech III is available in several temperature control modes LONMARK certified Space Comfort Control [SCC] for single zone, constant volume applications; including 100% make-up air application LONMARK certified Discharge air temperature control [DAC] for VAV or constant volume applications. Static pressure control of the supply fan and return/exhaust fan can also be included Time clock, lead lag, morning warm up, night set back, economizer pre-cool and flexible reset are all standard Published integration instructions for both forms of communication Unit mounted keypad and 4-line by 20-character display provide an enhanced user interface Compressor head pressure control that reliably cycles the condenser fans from sump temperature down to 45 F ambient Duct high pressure safety on all VAV units Figure 10: MicroTech III Keyboard CAT ROOFPAK PACKAGED SYSTEMS 10

11 Factory Installed and Wired Options The RPE and RDE contain the same air handler construction and controls as the RPS and RDT units. For complete detail refer to RPS Catalog 214 and RDT Catalog 217. For a copy of these catalogs, contact your local Daikin representative or visit DaikinApplied.com. Condensing Section Compressor spring isolation with suction and discharge line vibration absorbers Extra compressor unloaders that provide 6 stages (size ) or 8 stages (size ) of capacity control Compressor part winding start to reduce inrush current Replaceable core filter driers Hot gas bypass on one or both refrigerant circuits Electric sump heater that helps prevent the sump from freezing in cold weather. Heat tape is also included for the sump drain and supply water lines 1.5 kw electric unit heater and ambient ON-OFF thermostat for the service compartment Air Handling Section Multiple fan and coil options optimize reliability, efficiency, sound performance and first cost for varying cfm per ton operation. Units can be selected for make-up air applications Economizer systems come standard with outdoor and return air damper leakage rates of less than 1.5 cfm/ft 2 at 1" static pressure. Economizers are available with the following value add options Patented DesignFlow minimum outdoor air measurement and control system that is independently certified to control ventilation air within +/- 5% of set point from 1,594 to 37,126 cfm of outdoor air Static air mixers that provide optimum uniformity in mixed air temperature and reduce the chances of freezestat trips and localized coil freezing Economizers are available with return or exhaust fans SWSI airfoil return fans provide better building pressure and ventilation control on ducted returns Multiple propeller exhaust fans may save energy on low-pressure drop, ceiling plenum returns (see Economizer, Return Fan and Exhaust Fan Application on page 19) Variable frequency RAF and SAF drives for VAV control (exhaust fans always include a variable frequency drive) Supply and return fan belt guards Spring isolation (with optional seismic construction) Cooling coils are available in blow-through and drawthrough arrangements to optimize the use of fan and motor heat. See Figure 21 on page 22. Factory Installed and Wired Options In blow-through arrangements (RPE only), fan energy pre-heats the mixed air temperature before entering the cooling coil, providing greater sensible capacity and colder supply air temperature for a given compressor capacity In draw-through units, fan energy re-heats the air leaving the cooling coil. Draw-through systems provide greater latent cooling capacity, lower sensible heat ratios Gas and electric heat are available on RPE units with the following options Two-pass drum and tube heat exchanger with, fully modulating, FM approved burners for 3-to-1 or 20- to-1 (patented SuperMod ) turn down and optional IRI approval. Drum and tube heat exchangers feature all stainless steel construction. Selections are available to handle up to 100 F temperature rise Low watt density, nickel chromium electric heaters with branch short circuit, automatic reset and manual reset safety 1 or 2-row hot water or jet distributing steam coils with optional valve control and optional freezestats Supply fan sound attenuators with or without mylar coating of the acoustic insulation (RPE only) Generous face area, 2" pleated, 30% efficient panel filters and/or 65 or 95% cartridge filters are available Cartridge filters can be in the final, last in air flow position for hospital or laboratory applications (RPE only) Blank sections can be added for field-installed devices such as humidifiers and integral face and bypass coils Ultraviolet Germicidal Irradiation (UVGI) lamps are available factory installed in all RDE/RPE units to cleanse cooling coils and drain pans. The UVGI lamps irradiate the cooling coil and drain pan surfaces with light in the 254-nanometer wavelength of the light spectrum (UV-C). UV-C light has been proved effective in killing most bacteria, molds and viruses in both laboratory and practical application. In addition, the continuous cleansing action of the UV-C light also serves to continuously clean the coil and drain pan, improving long-term performance and reducing coil/drain pan maintenance. Daikin equipment and UVGI lights include (ETL) safety agency certification Figure 11: DesignFlow 11 CAT ROOFPAK PACKAGED SYSTEMS

12 Factory Installed and Wired Options Intelligent Equipment Intelligent Equipment (IE) from Daikin Applied is a secure, cloud-based controls solution that enables delivery of equipment and/or system information to customers via web or mobile devices. A power measurement module and communications gateway installed on Daikin equipment enables the unit to be directly connected to the Internet via wireless (cellular, WI-FI) or local area network (LAN), providing management, monitoring control analysis and decision-making functionality for Daikin rooftop systems and the facility. Features Remote monitoring and control of Daikin rooftop units Remote servicing capabilities Integration to the Energy Star Portfolio Manager Advanced data analytics including equipment performance, financial performance and building Comfort Index metrix based on ASHRAE Standard Dynamic user dashboards with photo-realistic graphics and responsive-design interface optimized for users mobile devices, tablets or PCs Secure, role-based user access Benefits Informed decision-making Increased equipment efficiency 24/7 monitoring capability Real-time equipment information Accelerated equipment payback Historical performance data Can be used with, or without, an existing building automation system (BAS) Figure 12: Intelligent Equipment Dashboards Customer Dashboard Technician Dashboard CAT ROOFPAK PACKAGED SYSTEMS 12

13 Factory Installed and Wired Options Daikin MictroTech III Rooftop Remote User Interface Each remote user interface is identical to its unit-mounted counterpart and offers the same functionality, including: Touch sensitive key pad with a 4 line by 20 character display format Digital display of messages in English language All operating conditions, system alarms, control parameters and schedules are monitored Features Can be wired up to 1,200 feet from unit for flexibility in placing each remote user interface within your building Unit-mounted switch enables the remote user interface during normal operation or the unit user interface for maintenance and service Benefits Allows you to access the user interface for each unit from one location, inside the building. Users need to learn one format because the remote user interface is identical to the unit-mounted version. Multiple Unit Applications For applications in which multiple units are connected in a common duct system, it is important to control all units from a common duct static pressure sensor and to control all operating units in unison. Centralized duct static pressure control can be accomplished through communication with the BAS network. Field-Installed Roof Curbs Constructed in accordance with NRCA guidelines using 12-gauge galvanized steel Fits inside the unit base around the perimeter of the air handling section and service compartment Duct frames are provided to allow duct connections to be made to the curb before the unit is placed. The unit seals to the duct frames Ship loose gasket seals between the unit and curb Separate condensing unit support rail allows an open condensing unit design and minimizes compressor noise and vibration transmission through the roof Figure 13: Remote User Interface Electrical and Controls Factory-powered service outlets complete with its own disconnect, short circuit protection and ground fault protection Smoke detectors in the supply and/or return air openings Marine lights in the supply and/or return/exhaust fan sections 13 CAT ROOFPAK PACKAGED SYSTEMS

14 Factory Installed and Wired Options Optional Water Treatment All evaporative condensing products require water treatment systems for proper operation. The water treatment system serves the following purposes: Controls organic contamination Reduces condenser fouling and corrosion Reduces cleaning frequency and water usage Overview Daikin RPE/RDE units come with a spray system, pump, sump strainer, automatic float controlled intake, and manual blowdown as standard. Daikin evaporative condenser rooftop systems can provide as much as 44% in compressor energy savings compared to competitive air-cooled rooftop units. Until now, chemical water treatment was required to prevent scale build-up and microbial growth in the moisture laden condenser section of these units. Daikin now offers an alternative: a chemical-free water treatment system that can substantially lower the cost of water treatment, eliminate the use of hazardous chemicals and simplify the water treatment process. Figure 14: Water Treatment System Eliminates Chemical Costs This system eliminates the use of hazardous chemicals, including scale inhibitors, biocides and corrosion inhibitors. Typical yearly savings range from $1,800 to $2,700 per year for a 150 ton evaporative condenser rooftop unit. Minimizes Corrosion Daikin uses only stainless steel, copper and PVC in its evaporative condenser plumbing. Clean, chemical-free water, saturated with precipitates by this system, does not attack these materials. Blowdown and Water Consumption Controlled blowdown is required on Daikin RPE/RDE units as it should be with all evaporative condensing products. It involves draining off a portion of the highly concentrated water from the bottom of the sump and replacing it with lower concentration make-up water to prevent scale. Scale protection is required because the evaporation process leaves behind solids (scale) that will coat the heat exchanger surfaces and sump. This reduces the capacity, efficiency, and life expectancy of the equipment. Manual blowdown occurs whenever the spray pump operates and a manual valve adjusts flow. This inevitably bleeds off too much [increased water costs] or too little [risking scale build up] water. Controlled bleed off is included with the Daikin water treatment controller. The concentration of scale forming solids is measured by water conductivity and the control opens or closes a solenoid to allow the proper amount of bleed off. The conductivity set point should be adjusted based on water analysis to maintain a desired cycles of concentration. Theoretical water consumption required for proper heat rejection is 1.8 gallons per ton hour. All of this water evaporates and none goes into the sewer. An additional 0.6 to 0.9 gallons per ton hour is also required for make up and blowdown. The exact amount should be determined by water analysis. The RPE/RDE includes a float valve and solenoid that automatically refills the sump as required. Blowdown must be handled in accordance with local codes and normal procedures are as follows: Daikin non-chemical water treatment system - used blowdown water often can be drained to the storm sewer (check local codes) Field installed chemical water treatment system - used blowdown must not be drained to the storm sewer and is usually drained to the sanitary sewer (check local codes) Because most water utilities charge for both intake and sanitary sewer water flows based on intake meter readings, sanitary sewer charges may be reduced if sewer flow is proven to be less than water intake. Daikin offers both intake and blowdown water meters to document reduced sewer flow [confirm details with your local utility]. These meters are not included in the basic water treatment option. Reduces Water Consumption Costs With this system, supply water typically can be cycled through the evaporative system six times before it must be drained off to prevent scale. With chemical treatment systems, only three to four cycles are possible. This represents a water consumption savings of about 10%. CAT ROOFPAK PACKAGED SYSTEMS 14

15 Factory Installed and Wired Options A Cleaner Environment Daikin evaporative condenser rooftop units equipped with a chemical-free water treatment system contribute to a cleaner environment by reducing energy usage and by eliminating the introduction of hazardous chemicals into the waste stream. Reduces Sanitary Sewer Costs Savings in sanitary sewer costs can be even more dramatic. That s because this system requires no sanitary sewer usage all condenser water, including blow-down, usually can be drained to the storm sewer or used for irrigation (check local codes). This represents a 10 to 15% water cost savings if sewer flow is measured (i.e., credit is given for the water that evaporates during the cooling process) and even more if it is not. Chemical-Free Benefits As a scale inhibitor, the Daikin chemical-free system uses pulsed electromagnetic fields to neutralize the charge on particles suspended in water, causing them to attract to each other rather than to form scale on plumbing and heat transfer surfaces. The particles grow, encapsulate any microorganisms, and precipitate out of solution as a powder. A cyclone separator removes the powder from the system during the blow-down process. For microbial control, the system uses pulsed electromagnetic fields to attack the cell walls of any microorganisms that are not encapsulated. As a result, TBC is typically 75% less than with chemical treatment systems. In fact, total bacterial count (TBC) is so low that biofilms are normally prevented. Easy Maintenance The Daikin chemical-free water treatment system has no moving parts and is easy to maintain. Inspection and monitoring are only required once or twice per quarter, as follows: Check the water conductivity (and clean conductivity sensor if necessary) Check total bacteria count (TBC) Inspect general operation and controller settings LEED Point Available Chemical-free water treatment systems qualify for a LEED point under the Innovation heading, per a Credit Interpretation Request posted on the USGBC website. 12 to 18 Month Payback The superior performance of the Daikin chemical-free system costs a little more up front than a chemical feed system, tanks, and pumps. However, the water and chemical savings generally provide a month payback, in addition to the financial benefit of cleaner water and heat transfer surfaces. Table 6 below shows typical yearly water treatment cost savings when using this system on a Daikin 150-ton evaporative condenser rooftop unit. Table 7 points out that, while there are water treatment costs associated with evaporative condensers, they are typically small compared to the total energy savings provided by a Daikin evaporative condenser unit. Table 5: Yearly Cost Savings Typical Chemical Treatment System Los Angeles New York City Water Cost $1,067 $628 Chemical Cost $2,000 $2,000 Total $3,067 $2,628 Daikin Chemical Free Treatment System Water Cost $923 $539 Chemical Cost $0 $0 Total $923 $539 Chemical-Free Savings $2,144 $2,089 Percent Savings 70% 79% Table 6: Yearly Cost Savings with Rooftop Unit Competitive Air Cooled Unit Los Angeles New York City Energy Cost $30,200 $17,860 Water Treatment $0 $0 Total $30,200 $17,860 Daikin RPE Unit with Chemical Free Treatment System Energy Cost $22,100 $12,375 Water Treatment $923 $539 Total $23,023 $12,914 RPE Cost Savings $7,177 $4,469 Percent Savings 24% 28% NOTE: All energy analysis and comparison charts provided above are estimates and have been generated using Daikin Energy Analyzer software. Actual customer results may vary. For access to the Daikin Energy Analyzer software, contact your local Daikin sales representative CAT ROOFPAK PACKAGED SYSTEMS

16 Factory Installed and Wired Options Figure 15: Daikin Water Treatment Option Sump water coil-pipe treatment module Makeup water transformer To Spraybar Sump water transformer To Spraybar Flowmeter Cyclone seperator hand valve (hidden) Cyclone seperator Sump overflow Conductivity sensor Conductivity controller Makeup water control valve Auto purge controller Heat-tape all components from customer connection point to makeup water control valve Makeup water coil-pipe treatment module Ball valve actuators for blowdown Makeup water connection point to sump tank. Side stream connection to sump tank Cleanout Customer makeup water connection point Manual shutoff Sump Pump Blow down and drain System drain valve and actuator CAT ROOFPAK PACKAGED SYSTEMS 16

17 Application Considerations The RPE and RDE require many of the same application considerations as Daikin RPS and RDT units. More detail is provided in RPS Catalog 214 and RDT Catalog 217. For a copy of these catalogs, contact your local Daikin representative or visit DaikinApplied.com General Intended for normal HVAC use. Consult factory if cataloged operating range is exceeded, such as make up air. Compressor cooling below 45 F is not allowed Rig the unit in accordance with the instructions provided in the Installation Manual IM 791. Split units are available to reduce rigging weight and may be required if the total length exceeds 52 ft. For a copy of IM 791, contact your local Daikin representative or visit DaikinApplied.com Fire dampers may be required by code. They are not included Qualified Start-up of the unit in accordance with the IM 791 is required Clean off any road chemicals, such as winter salt, when the unit is received Proper water treatment must be provided before unit start-up Filters Application Considerations Filters should be replaced on a regular basis to avoid excessive pressure drop increases, especially on high efficiency cartridge filters Fan selection must consider dirty filter losses. Using a filter pressure drop midway between clean and dirty values is recommended unless maintaining minimum cfm is critical Daikin RPE units offer last in air stream final filters. They require special consideration The Daikin design uses full double-wall construction down stream of the final filters Cooling coils must be in the draw-through position. Final filters down stream of gas and electric heaters must be rated for 500 F temperatures. Maintenance personnel must use properly-rated replacement filters Location and Curb/Rail Support The structural engineer must verify that sufficient roof strength is provided Maximum unit pitch is 1/16 in. per foot. Curbs or supporting rails must be rigidly supported along the entire length of the unit to prevent deflection that results in door interference Gaskets must be installed between the curb and the unit, per IM 791 Curbs must be installed per NRCA guidelines See Roof Curbs on page 55 Avoid locating the unit near any heat source, exhaust, smoke stack, or any source of air-borne particles or chemicals Local codes must be followed regarding fastening the unit to the curb/rail and the curb/rail to the building. This is especially critical in higher risk, hurricane or seismic zones Refer to the Acoustics on page 18 to avoid noise and vibration problems Daikin curbs include supply and return opening support frames and perimeter channels that seal to the unit as it is placed on the curb. Therefore, duct connections can be made to the curb before the unit is placed 17 CAT ROOFPAK PACKAGED SYSTEMS

18 Application Considerations Acoustics Ducted and radiated sound power ratings are available from your local Daikin sales representative. The designer is responsible for addressing these sound levels. The following guidelines will help to achieve the desired sound levels in the occupied space. Locate the unit as far away from sound sensitive areas as possible. Refer to the Location and Curb/Rail Support on page 17 Minimize supply and return fan TSP and select the fan as close to peak efficiency as possible. Avoid the do not select areas on the fan curve. Daikin offers several different fans per model size to allow for various design conditions. Refer to Fan Performance Data on page 44 Three different sound paths from the unit to occupants and/or neighbors must be considered: 1. Radiated path Use a concrete deck or pad when the unit must be located over sound sensitive areas. If this isn t possible, provide extra acoustical insulation under the condensing unit Only the supply and return ducts, and the essential plumbing and electrical connections should penetrate the acoustical insulation or roofing below the unit. The outside perimeter of the ducts must be sealed after they are installed If a built-up roof with metal decking is used, then the area inside the curb perimeter requires special attention: Provide an inverted 6" channel around the inside perimeter of the curb and seal to the curb Acoustical insulation must be installed above the decking and the 6" channel 2. Vibration path Locate the unit s center of gravity close to a main support beam to minimize roof deflection and vibration transmission into the building Daikin offers 2" deflection, supply and return fan spring isolation or rubber in shear isolators. The rubber in shear isolators should only be used when vibration isolation is clearly not required in the rooftop, such as when the unit is mounted on spring isolated curbs, spring isolated rails or the ground Daikin offers compressor spring isolation, including the necessary refrigerant line vibration eliminators Internal spring isolation options may be insufficient for some applications. Spring isolation of the entire unit may be required 3. Air-borne path through the supply and return openings Use 2003 ASHRAE Fundamentals Chapter 43 to help reduce ducted noise and minimize duct turbulence. Maintain straight ducts to and from the unit and avoid abrupt changes in duct size and direction. Avoid turns opposed to the fan wheel rotation. If 90 elbows are required, use turning vanes Use as much insulated return duct as possible and include at least one elbow and 15' of length. Maximum recommended velocities are fpm Allow for duct break out and use oval or round duct whenever possible Insulate the first 20' of supply duct. The first 20' of rectangular duct should be routed over non-sensitive areas and avoid large aspect ratios. Maximum recommended velocities are fpm Daikin offers factory-installed discharge plenums with optional perforated liners. The plenum provides several db of attenuation and discharges the air at a more uniform, relatively low velocity. Ducted supply noise can be further reduced by adding optional sound attenuators between the supply fan and the unit discharge Route the return air path through the length of the curb to add distance between the unit return opening and the building return opening CAT ROOFPAK PACKAGED SYSTEMS 18

19 Application Considerations Economizer, Return Fan and Exhaust Fan Application Rooftop economizer applications usually require return or exhaust fans to properly control building pressure and maintain minimum ventilation. Daikin offers both exhaust and return fan capability. They are not generally interchangeable for a given design. In general: Return air fans (RAF) should be used on ducted return systems (return ESP exceeds in.) Properly selected propeller exhaust air fans (EAF) can successfully operate and save energy on open return systems (return ESP is less than in.) Supply air fan (SAF) selection depends on whether a return or exhaust fan is used RAF system-saf handles only the supply ESP at design EAF system-saf handles both the supply and return ESP at design (EAF is OFF) Figure 16 illustrates why supply fan only units have problems, especially as return ESP increases. No exhaust will occur from the rooftop because the economizer section must be at a negative pressure The air balancer must adjust the outdoor air damper to generate large pressure drops at minimum ventilation settings (about 0.9" in Figure 16) Figure 17 illustrates how the addition of a return fan corrects these problems. The return fan is responsible for return system ESP and maintains a slightly positive pressure in the economizer section (about +0.1 in. in Figure 17) to allow for exhaust air control and a more suitable outside air intake pressure. Exhaust fans are very different than return fans and can not maintain proper building pressure and ventilation control as return ESP increases. The EAF is normally off during non-economizer operation. During these minimum outdoor air conditions, the system essentially acts like a supply fan only system When the exhaust fan cycles OFF, there is no device available to maintain a positive pressure for relief, the mixed air plenum pressure dramatically changes and minimum ventilation air control and space pressure control are lost An exhaust fan s performance weaknesses diminish as return ESP decreases. Properly selected and controlled propeller exhaust fans can successfully operate and save energy at reduced return ESP designs. At system operating conditions where a single fan can be used successfully, it generally will be more efficient than operating series fans under the same total load. When the exhaust fan turns off, the supply fan can more efficiently handle both the supply and return duct loads At the relatively high cfm, low static pressure conditions of exhaust/return application, exhaust fans can be selected closer to their peak design efficiency than can full return fans. This allows them to run more efficiently throughout their operating range. Therefore, when return duct losses don t dictate the use of a return air fan, exhaust fans are an efficient alternate. Figure 16: AF Only System Static Pressures with 1" Return Duct ESP $) J5). K J AJ # 5 K F FO - 52 ') J5).1 AJ 1 JA H = 5 2 ) 4 )?? K F A 5 F=?A)J 5 J= JE? 2 HA IIKHA ' 1 4 BJ F -? E A H 5 A? JE - ) 4 AJKH - 52 Figure 17: RAF System Allows Proper Exhaust and Outdoor Air Control ') J5).1 AJ ) J ) 1 AJ )J IF D AHE?2 HA IIKHA ) J4). KJ A J $) J5). K J AJ ') J4).1 AJ 19 CAT ROOFPAK PACKAGED SYSTEMS

20 Application Considerations Variable Air Volume (VAV) Daikin Rooftop VAV options include everything required to provide the full advantages of true shut-off VAV. Bypass VAV systems do not offer any fan energy savings at light load. Variable Frequency Drives for all indoor fans maximize part load fan efficiency and minimize fan sound generation Indoor fan volume control based on supply static pressure and building pressure Up to 2 supply duct sensors to properly respond to building diversity (such as east-west variation) Constant discharge temperature control. Shut-off VAV offers the following advantages Reduces first cost and energy due to building diversity Reduces indoor fan energy requirements at light load Provides the opportunity for efficient multiple zone control from a single unit and to match changing occupancy demands VFDs turn down in accordance with Figure 18 The benefits of Daikin airfoil fans are particularly applicable to VAV applications. Better efficiency and less noise at the medium static pressures associated with VAV Airfoil fans are much more forgiving than forward curved fans if unexpected variations in ESP occur They are non-overloading (bhp is fairly constant for a given RPM) and require less safety factor in motor selection They have steeper RPM lines (less variation in cfm for a given variation in ESP) Multiple forward curved fans are often used and they risk unstable fan paralleling at light load MicroTech III Control Supply fans are controlled to maintain constant supply duct static pressure. Run pressure-sensing tubes to the desired location (generally at the end of the main trunk) Use a second sensor when there is more than one main trunk, multiple floors, or significantly varying zones (such as east and west sides of a building) Return/exhaust fans are controlled to maintain building pressure in one of two ways. Daikin s exclusive Vanetrol supply/return fan tracking is generally preferred. Vanetrol is adjusted at system air balance to maintain proper building pressure throughout the expected loading conditions. This reduces the effect of wind, climate variation and doors opening and closing Direct building sensing control is available for exhaust fans or any return fan application that cannot predictably track the supply fan Daikin generally offers more steps of compressor capacity control than the industry norm, as well as HGBP, and these capabilities should be included on VAV applications to minimize variations in duct temperature. Figure 18: VFD Turndown CAT ROOFPAK PACKAGED SYSTEMS 20

21 Application Considerations Unit Operating Range Fan Operating Range The acceptable system operating range of the Daikin rooftop unit is determined by all of the following characteristics. Each of these limiting factors must be considered for proper performance and component design life. 1. Unstable fan operation 2. Maximum fan rpm 3. Maximum cabinet static pressure 4. Maximum face velocity (cooling coil is most important) 5. Minimum furnace or electric heater velocity 6. Turndown capability on VAV applications 7. Compressor operating pressures Figure 19 illustrates these limiting factors with the exception of items 6 and 7 above. The shaded area indicates the design operating range of the fan. For optimal efficiency, select fans as close to the fan s peak static efficiency line as possible. This line is the first system curve to the right of the unstable line illustrated. VAV fan selections must also allow for keeping the fan away from the do not select area at minimum design cfm. Cooling coil maximum face velocity is based on moisture blow off limitations and laboratory testing. 650 feet per minute maximum face velocity for 8 and 10 fin per inch coils. 600 feet per minute maximum face velocity for 12 fin per inch coils. Cooling coil minimum face velocity is 200 feet per minute for any coil selection. VAV systems must be designed such that this velocity is maintained at minimum airflow. Maximum design ambient wet bulb temperature varies per unit, but is at least 85 F. Evaporative condenser units are an excellent choice for high ambient applications. The minimum ambient temperature for compressor operation is 45 F. The MicroTech III Controller is set to prevent compressor operation below that temperature and use the economizer only when cooling is required at a lower ambient. Figure 19: Fan Selection Boundary Do Not Select 21 CAT ROOFPAK PACKAGED SYSTEMS

22 Application Considerations Indoor Fan and Motor Heat, Blow-Through vs. Draw-Through Cooling Indoor Fan and Motor Heat The indoor fan and motor electrical consumption is a sensible cooling load approximately equal to 2.8 MBh per bhp (depending slightly on motor efficiency). This occurs at the fan. See Figure 20 and Figure 21. The fan and motor preheat the mixed air before it enters a blowthrough cooling coil. The fan and motor reheat the air leaving a draw-through cooling coil. Refer also to 2001 ASHRAE Fundamentals Handbook, Chapter 31 Figure 20: Blow-Through vs. Draw-Through Concept Fan and motor temperature rise is equal to Btuh / (1.08 cfm) and is typically about 3 F Due to fan and motor heat placement (Figure 20), blowthrough coils provide a high sensible heat ratio while draw-through coils provide more latent cooling per total ton. Blow-through coils achieve a higher sensible heat ratio because they operate with a higher coil approach temperature and a lower entering relative humidity. Conversely, draw-through coils cool air at a lower approach temperature and a higher relative humidity, increasing latent cooling Blow-through coils effectively provide colder supply air temperatures per ton of air conditioning and greater sensible heat ratio. This potentially allows a significant reduction in design cfm for buildings with high sensible heat ratios and a resulting reduction in building energy use Figure 21: Blow-Through and Draw-Through Performance Comparison MAT 3 B.T. Preheat 3 D.T. Reheat Coil EAT Is Different Coil LAT Is Different CAT ROOFPAK PACKAGED SYSTEMS 22

23 Application Considerations Recommended Clearances Service Clearance Allow the recommended service clearances shown in Figure 22. Provide a roof walkway along two sides of the unit for service and access to most controls. Cooling Coil, Heat, and Supply Fan Service Clearance An additional clearance of 24" is recommended adjacent to the cooling coil, heat, and supply fan sections. Outdoor Air Intakes Do not locate outside air intakes near exhaust vents or other sources of contaminated air. If the unit is installed where windy conditions are common, install wind screens around the unit, maintaining the clearances specified. This is particularly important to prevent blowing snow from entering outside air intakes. Overhead Clearance 1. Unit(s) surrounded by screens or solid walls must have no overhead obstructions over any part of the unit. 2. The area above the condenser must be unobstructed in all installations to allow vertical air discharge. 3. The following restrictions must be observed for overhead obstructions above the air handler section: a. There must be no overhead obstructions above the furnace flue or within 9 inches of the flue box. b. Any overhead obstruction shall not be within 2 inches of the top of the unit. c. A service canopy must not protrude more than 24 inches beyond the unit in the area of the outside air and exhaust dampers. d. Flue box outlet must extend above any obstructions. Figure 22: Service Clearances 72" Service Clearance on 4 sides except as indicated 24" 72" Clearance to end of unit or end of outside hood Roof Walkway Adjacent to Cooling Coil, Heat, and Supply Fan Sections CAT ROOFPAK PACKAGED SYSTEMS

24 Application Considerations Ventilation Clearance Unit(s) surrounded by a screen or a 50% open area fence: 1. The bottom of the screen should be a minimum of 1 ft. above the roof surface. 2. Minimum distance from the unit to screen is the same as the recommended service clearance. 3. Minimum distance, unit-to-unit = 120 in. Figure 23: Ventilation Clearances Unit(s) surrounded by solid walls: 1. Minimum distance from the unit to the wall is 96 inches for all sizes. 2. Minimum distance from the unit to another unit is 120 inches. 3. Wall height restrictions: a. No restrictions if there is a wall on one side only, or on two adjacent sides. b. The wall height is restricted to no more than the unit height with walls on more than two adjacent sides. Maximum Allowable Overhead Canopy Area 24" Max 24" Max Flue Box 9" Min to Flue Box Typical All Sides 2" Topof Unit To Overhead Obstruction CAT ROOFPAK PACKAGED SYSTEMS 24

25 Application Considerations Control and Power Wiring Wiring must be done in accordance with the NEC and local code. For wire sizing instructions, see Supply Power Wiring on page 60. All units require , , , or power. Size wire in accordance with tables or of the National Electric Code. Wires should be sized for a maximum 3% voltage drop. Copper conductors must be used. Actual voltage at the unit connection must be within +/- 10% of nameplate voltage at all times. Daikin offers several power connection options. Single power connection with a terminal block or nonfused disconnect are normally the most economical. Systems served by emergency generators often require two power connections (with terminal blocks or non-fused disconnects). The generator normally serves only the air handler and controls portion so the condensing unit must be powered separately. Each unit is provided with a separate 115 volt convenience outlet that requires a separate power connection per the NEC. A second, 115 volt power supply is required to power the optional unit heater for the service compartment. Most units require a zone temperature sensor for night heat and other functions. The sensor must be properly placed so that its temperature reflects the zone requirements. Avoid outside walls, sunlight and close proximity to supply air or heat generating equipment. A return air sensor can be substituted for the space sensor if necessary. Altitude Adjustments Fan curve performance is based on 70 F air temperature and sea level elevation. Selections at any other conditions require the following adjustment for air densities listed in Table 7. Higher elevations generally require more RPM to provide a given static pressure but less bhp due to the decrease in air density. 1. Assume 32,000 cfm is required at 3.11" TSP. The elevation is 5000 ft. and 70 F average air temperature is selected. A 40" DWDI airfoil fan is selected. 2. The density adjustment factor for 5000 ft. and 70 F is TSP must be adjusted as follows; 3.11" / 0.83 = 3.75" 4. Locate 32,000 cfm and 3.75 on the fan curve. RPM = 900 and bhp = The required fan speed is 900 RPM. 5. The consumed fan power at design = 27.5 bhp 0.83 = 22.8 bhp. Figure 24: RPE 105C - 135C 40 in. DWDI Airfoil Table 7: Temperature and Altitude Conversion Factors Air Temp ( F) Altitude (Feet) CAT ROOFPAK PACKAGED SYSTEMS

26 Application Considerations Furnace Performance Gas heat performance data is based on standard 70 F combustion air temperature and zero feet altitude (sea level). Furnace altitude derate may be 4% per 1000 feet above 2000 feet due to lesser combustion air density. However, if design ambient is cold enough, then the combined affect of colder temperature and altitude may have an offsetting impact on combustion air density. Example: A 1000 MBh furnace at 70 F ambient and at an altitude of 5000 feet is derated ( = 0.12). At 1000 MBh input ( MBh), the actual input is ( = 880 MBh) at 5000 feet. Above 6000 feet, consult factory. Freezing Concerns Freeze protection measures must be taken for any rooftop exposed to freezing conditions. The owner and building designer must take primary responsibility based on the exact climate and installation conditions. Drain all condenser water as soon as the climate allows the economizer to provide all required cooling. The optional sump heater is recommended to protect the sump if ambient temperatures can drop to freezing conditions (even at night). Spray System The spray tree and nozzles are not vulnerable to freezing because water drains out of them when the spray pump is OFF. Remove the sump drain plug whenever the unit is not in operation to prevent precipitation from building up in the sump and drain. Two freeze protection options are required to prevent the rest of the spray system from freezing. 1. An optional service vestibule heater provides primary freeze protection of the spray system enclosed in the vestibule. A thermostat turns the unit heater on when vestibule temperature drops to 40 F. 2. A sump heater is a recommended option that includes the following: An ambient thermostat-controlled insertion heater for the sump. Heat tape, insulation and thermostat for the sump drain. Heat tape, thermostat and insulation is included on the high pressure, factory water inlet piping upstream of the float control valve. An additional 10 feet of heat tape is provided to protect field connections. The installer must provide additional heat tape as required and insulate all field piping. An emergency drain solenoid opens up whenever the sump temperature drops near freezing and the spray system drains onto the roof. Hot Water and Steam Coils The RPE/RDE economizer offers better mixing capability than competitive rooftops but it cannot protect a hydronic coil from localized freezing. Optional air mixers are available to reduce air stratification and freezing concerns. Glycol is strongly recommended for hot water coils. It is the only reliable protection in the event of a power failure. Glycol s impact on coil and pump performance must be considered. An optional, non-averaging coil freezestat is offered on the downstream face of the heating coil. The outdoor dampers are shut, the fan is shut off, and the heating valve is fully opened, if freezing temperatures are experienced. The freezestat must be set somewhat above freezing temperatures to improve protection and may experience nuisance trips. It can not protect the coils during a power outage. Freeze protection strategies must not cause the cabinet temperature to exceed 150 F or motors and electrical equipment may be damaged. The field installed supply and bleed off water lines can enter the unit through the floor, inside the curb perimeter. This may provide sufficient protection depending on the temperature inside the curb. Use freeze protection if there is any concern the temperature inside the curb may fall below freezing. If no curb is provided, or field water piping enters the side of the unit, then additional measures are required such as heat tape and proper pipe insulation. Hot water and steam coil piping can enter the floor of the unit in the heat section and requires similar consideration. Water Treatment All evaporative condensers require proper water treatment. See Optional Water Treatment on page 14. The purpose of the water treatment system is to: Control organic contamination. Reduce condenser and sump scaling, fouling and corrosion. Reduce the required cleaning frequency. Proper water treatment involves two mandatory components (treatment and bleed off) and may also require a solid separator system depending on water quality. CAT ROOFPAK PACKAGED SYSTEMS 26

27 Application Considerations Condenser Water Connections Supply and return condenser water piping, plus field connections for chemical water treatment, are shown in Figure 25. Supply water can enter the floor of the service vestibule. Space is allowed in the vestibule for chemical tanks. Condenser bleed off (or return) connections allow easy drainage to a sanitary sewer through the floor of the vestibule. The spray operation washes particles out of the condenser air and condenser heat rejection evaporates water. This process leaves behind minerals and particles that were contained in the water. Water bleed off and water treatment are required to prevent the build up of scale, sludge and micro-organisms on the tube bundles and in the sump. These must be installed prior to unit start-up. See Optional Water Treatment on page 14. The theoretical water consumption required for proper heat rejection is 1.8 gallons per cooling ton hour. A nominal 100- ton unit, running at 50% capacity or 50 tons, evaporates 90 gallons of water per hour while rejecting condenser heat. Additional water must be added to the sump and bled off to the sanitary sewer to remove particles and minerals that accumulate in the water during operation. The required amount of bleed off varies with the water quality and is generally 0.6 to 0.9 gallons per ton hour or 33-50% of the theoretical evaporation water. Bleed off can be controlled in two ways. The RPE/RDE is provided with a manual shut off valve that can be used to adjust for a constant flow rate of bleed off water. This standard bleed off system can easily bleed off too much or too little water. Controlling bleed off with a solenoid valve, based on water conductivity or some other measure of particle concentration should be used. It is included in the RPE/ RDE water treatment option. The RPE sump also has a float control that automatically opens the supply water solenoid and replaces water lost in evaporation and bleed off. Water utility costs are usually based on the combination of water usage and sewer discharge. Only the bleed off portion of the water used by an evaporative condenser drains to the sewer (about 25-33% of total water used). Therefore, the sewer component of the cost of water may be reduced significantly if approved water meters are installed in the intake and bleed lines. The difference in meter rates reflects evaporation (water that will not go to the sewer) and this can be applied as a credit to the total water bill. Consult your local water utility for details. Figure 25: Condenser Water Piping and Connections Water Consumption To Spray System Optional Water Treatment Controller Spray Pump Manual Shut off Valves From Optional Separator Automatic Supply Water Valve (Float Controlled) Manual Drain Valve Supply to Sump Optional Freeze Protection Drain Valve Field Bleedoff or Drain Connection Hose Bib and Manual Shut off Valve Field Supply Water Connection To Spray System Recommended Water Piping Entrance Through the Curb From Sump Removable Sump Screen Sump Drain Left Open for Shipment 27 CAT ROOFPAK PACKAGED SYSTEMS

28 Application Considerations Selection Instructions Building design and unit selection must allow for code compliance and installation limitations. The Daikin Rooftop unit offers excellent flexibility to meet diverse application requirements. This catalog includes summary performance tables at several operating conditions. Performance at other conditions can be estimated by interpolation but accuracy may suffer. Extrapolation often results in unreliable or damaging operating conditions and should not be used without factory guidance that is available through your local sales representative. Contact your Daikin representative for custom selections at specific design conditions. Selection Example Selection based on design criteria: 38,000 supply cfm at 2.00" ESP 36,000 return cfm at 0.75" ESP Sea level location using 60 Hertz power 95/75 F cooling ambient temperature 80/67 F cooling mixed air temperature [MAT] Total cooling loads requirements: 115 total tons 87 sensible tons Total sensible loads allow for: 50 hp SAF motor 25 hp RAF motor Gas furnace requirements: 1520 MBh of design heating 9" gas pressure available at the unit Furnace to only be used at design cfm for morning warm up and night heat An RPE unit must be used since a furnace, or electric heat, or final filters are required. Unit includes: Economizer plus return fan 65% filters plus pre-filters Cooling Selection Gross and net cooling The tables within the section Cooling Capacity Data on page 32 provide gross cooling or DX coil capacity based on DX coil entering air temperature (EAT). Net unit cooling capacity = [Gross cooling capacity] - [fan/motor heat] Fan/motor heat is critical. Refer to Indoor Fan and Motor Heat, Blow-Through vs. Draw-Through Cooling on page 22. Fan/motor heat = 2800 Btuh per bhp Fan/motor temperature rise (TR) = Btuh / (1.08 cfm) Mixed air vs. entering air temperature [MAT vs. EAT] Draw-through coil EAT = MAT Blow-through coil EAT = MAT + TR Blow-through EDB = mixed air EDB + TR Use a psychometric chart to find blow-through EWB. Selection From Capacity Tables Blow-through vs. draw-through. Refer to Indoor Fan and Motor Heat, Blow-Through vs. Draw-Through Cooling on page 22. Required sensible heat ratio < 80% [87 / 115 = 76%] An RPE is required due to the gas heat requirement. Therefore a draw-through RPE will be considered first. The RPE unit is available with both a low and high airflow DX coil. Refer to Table 8: Physical Data, RPE/RDE 076C - 150C on page 31. First select a high and low airflow coil with sufficient capacity. The RPE 110 with high airflow coil has sufficient capacity. No low airflow coil has sufficient capacity. Check coil velocity on all possible selections. High airflow face area = 76.0 square feet face velocity = 526 feet per minute. Low airflow face area = 60.8 square feet face velocity = 658 feet per minute The low airflow velocity is too much per Unit Operating Range on page 21. The RPE 110 [with high airflow coil] is sufficient per Table 16 on page 35. RPE 110 provides total tons. RPE 110 provides 90.8 tons of sensible capacity. RPE 110 power consumption compressor kw (see Table 16 on page 35). 4.0 condenser fan and pump kw (see Table 20 on page 37). RPE 110 fan and motor heat must still be verified to be less than 50 = 25 bhp [per fan selection ] to be sure that net cooling capacity is sufficient. CAT ROOFPAK PACKAGED SYSTEMS 28

29 Application Considerations Heat Selection See Catalog 214 or 217 for hot water, steam and electric heat selection instructions. Furnace Selection See Table 24 on page 40 and Table 25 and Table 26 on page 41. Table 24 and Table 25 indicate all of the furnace output capacities available. Output capacity is the true measure of furnace capacity Output capacity = Input capacity furnace efficiency Furnace efficiency = 80% for Daikin furnaces [similar to most direct fired furnaces] Net unit heating capacity = Furnace heating capacity + fan/motor heat = Furnace heating capacity + ( ) 2800 = Furnace heating capacity + 210,000 Btuh Net heating capacity must satisfy the heating load of 1520 MBh. A 1400 MBh furnace is the correct choice. 1,400,000 Btuh + 210,000 Btuh exceeds the 1,520 MBh requirement. Assuming actual bhp exceeds (1,520,000-1,400,000) / 2800 = 42.9 bhp Baffle selection is based on design airflow and Table 22 on page 38. Baffle A has the greatest air pressure drop. Use baffle A from 21,000 to 37,999 cfm. Baffle B has the next greatest air pressure drop. Use baffle B from 38,000 to 38,999 cfm. Furnace air pressure drop at design air flow Refer to Table 24 for a 1400 MBh furnace with B baffle. 0.86" = furnace air pressure drop. Minimum inlet gas pressure Refer to Table 25 for a 1400 MBh furnace. Minimum inlet gas pressure = 8.8" for the standard modulating burner. 5.0" for the 20:1 high turndown, modulating burner. Furnace air temperature rise = Output Btuh 1,400,000 / 1.08 cfm = 32.4 F Filter Selection Refer to Table 8: Physical Data, RPE/RDE 076C - 150C on page 31 and Table 29: Component Pressure Drops on page 43. Table 8 shows the filter face area options. Table 29 shows performance data for each filter option: Clean filter air pressure drop Maximum airflow Selection for 65% filter at 38,000 cfm per Table 29. The medium airflow option is required Clean air pressure drop = 0.65" 30% prefilter clean air pressure drop = 0.36" Maximum recommended, dirty filter pressure drop [PD] for these filters: 0.7" for the 30% prefilter 1.0" for the 65% filters Please note that 95% filters are not part of this selection. 95% filter, maximum recommended, dirty PD = 1.20". Average filter PD = ( ) / 2 = 1.35" Daikin generally recommends selecting the supply fan based on average filter PD. This allows airflow to best match specifications. Adjustments can be made to maintain critical, minimum airflow CAT ROOFPAK PACKAGED SYSTEMS

30 Application Considerations Fan Selection Refer to the following: Table 8: Physical Data, RPE/RDE 076C - 150C on page 31 and Table 29: Component Pressure Drops on page 43. Fan Operating Range on page 21. Fan Performance Data on page 44. Return Air Fan and Exhaust Air Fan Selection Refer to Return Fans & Exhaust Fans on page 44 for 36,000 cfm at 0.75" ESP. The 44" SWSI return fan performance requires 19.5 bhp at 810 RPM bhp satisfies the RAF bhp specification. Supply Fan Selection The unit is specified to have a return fan. Therefore the supply fan must only handle internal APD and supply duct ESP. See Economizer, Return Fan and Exhaust Fan Application on page 19. Internal APD per Table 28 on page 42 and Table 29 on page 43. Economizer with return fan = 0.52" High airflow, 12 fpi, DX coil air pressure drop = 0.80" Gas furnace = 0.86" Average filter air PD = 1.35" TSP = ESP = 5.54" SWSI Plenum vs. DWDI Supply Fan Selection Each type should be considered based on maximum efficiency and customer preference. DWDI fans are available on RPE, blow-through or draw-through units and must be used due to the furnace requirement. SWSI fans are only available on RDE, draw-though units. No blow-through coils or filters No furnaces or electric heat They offer advantages with side discharge Pick the optimum SAF for 38,000 cfm and 5.54" TSP 40" DWDI = 47.8 bhp and 1085 RPM (Figure 37 on page 46) 36" DWDI = 50.1 bhp and 1288 RPM (Figure 36 on page 46) 33" DWDI = do not select The 40" fan is superior. 5% more efficient and, therefore, quieter Saves a motor size Meets the 50 hp supply fan allowance We can now verify acceptable net heating and cooling capacities. Actual supply and return fan bhp = = 67.3 Acceptable for cooling (67.3 < ) Acceptable for heating (67.3 > 42.9) CAT ROOFPAK PACKAGED SYSTEMS 30

31 Physical Data Table 8: Physical Data, RPE/RDE 076C - 150C Physical Data Data Unit Size 076C 089C 100C 110C 130C 140C 150C Nominal Capacity (tons) Nominal Airflow (cfm) Type Reciprocating Quantity - hp , Compressor Std. capacity control Opt. capacity control Condenser Fans No. - Dia. (In.) Condenser Fan Motors No. - Hp Type SWSI Airfoil No. - Dia. (In.) 1-44, 49 Supply Fans Motor hp range 5-75 Type DWDI Airfoil No. - Dia. (In.) 1-33, , , , , , , 40 Motor hp range Type SWSI Airfoil Return Fans No. - Dia. (In.) Motor hp range Type Propeller Exhaust Fans Diameter (In.) Quantity 2-3 per unit 2-3 per unit 2-3 per unit 2-3 per unit 2-3 per unit 2-3 per unit 2-3 per unit Motor hp 5 each 5 each 5 each 5 each 5 each 5 each 5 each Rows 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 Evaporator Coils FPI 8, 10, 12 8, 10, 12 8, 10, 12 8, 10, 12 8, 10, 12 8, 10, 12 8, 10, 12 F.A., small (sq. ft.) F.A., large (sq. ft.) Type - Rows 5WH-1 5WH-1 5WH-1 5WH-1 5WH-1 5WH-1 5WH-1 Hot Water Coils Type - Rows 5WS-2 5WS-2 5WS-2 5WS-2 5WS-2 5WS-2 5WS-2 FPI Face area (sq. ft.) Type - Rows 5JA-1, 2 5JA-1, 2 5JA-1, 2 5JA-1, 2 5JA-1, 2 5JA-1, 2 5JA-1, 2 Steam Coils FPI 6, 12 6, 12 6, 12 6, 12 6, 12 6, 12 6, 12 Face area (sq. ft.) Input (MBh) 625, 800, 812, 988, 1000, 1250, 1375, 1750, 1875, 2500 Gas Furnace 2 Nom. Output (MBh) 500, 640, 650, 790, 800, 1000, 1100, 1400, 1500, 2000 Electric Heat 3 Nom. Output (kw) 80, 100, 120, 160, 200, 240, 280, 320 Type 30% Pleated Panel Filters Area (sq. ft.) No. - size (in.) Type Prefilter, Standard Flow Prefilter, Medium Flow Area (sq. ft.) No. - size (in.) Prefilters (for Cartridge Filters) Type Prefilter, Medium Flow Prefilter, High Flow Area (sq. ft.) No. - size (in.) Type 65% or 95% Standard Flow 65% or 95% Medium Flow Area (sq. ft.) Cartridge Filters No. - size (in.) Type 65% or 95% Medium Flow 65% or 95% High Flow Area (sq. ft.) No. - size (in.) Rated in accordance with ARI Standard Gas furnace size availability is limited by minimum airflow. See Table 24 on page Electric heat availability is limited by minimum airflow, See through. See Table 23 on page CAT ROOFPAK PACKAGED SYSTEMS

32 Cooling Capacity Data Table 9: RPE/RDE 076C Low Airflow Coil Cooling Capacity Data Unit Data Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW cfm row 12 fpi cfm row 12 fpi cfm row 12 fpi DO NOT SELECT NOMINAL CAPACITY Table 10: RPE/RDE 076C High Airflow Coil Unit Data Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW cfm row 12 fpi cfm row 12 fpi cfm row 12 fpi DO NOT SELECT NOMINAL CAPACITY CAT ROOFPAK PACKAGED SYSTEMS 32

33 Cooling Capacity Data Table 11: RPE/RDE 089C Low Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY Table 12: RPE/RDE 089C High Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY 33 CAT ROOFPAK PACKAGED SYSTEMS

34 Cooling Capacity Data Table 13: RPE/RDE 100C Low Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY Table 14: RPE/RDE 100C High Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY CAT ROOFPAK PACKAGED SYSTEMS 34

35 Cooling Capacity Data Table 15: RPE/RDE 110C Low Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY Table 16: RPE/RDE 110C High Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY 35 CAT ROOFPAK PACKAGED SYSTEMS

36 Cooling Capacity Data Table 17: RPE/RDE 130C High Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 12 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY Table 18: RPE/RDE 140C High Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 10 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY CAT ROOFPAK PACKAGED SYSTEMS 36

37 Cooling Capacity Data Table 19: RPE/RDE 150C High Airflow Coil Unit Data cfm 5 row 12 fpi cfm 5 row 10 fpi cfm 5 row 10 fpi Entering Air Ambient Wet Bulb Temperature DB WB TH SH KW TH SH KW TH SH KW DO NOT SELECT NOMINAL CAPACITY Table 20: RPE/RDE Condenser Fan and Spray Pump Power Consumption 1.5 hp Spray Pump on all units 1.8 kw per condenser fan motor Unit Size Number of Condenser Fans Spray Pump & Condenser Fan Total kw RPE 076C-100C RPE 110C-150C CAT ROOFPAK PACKAGED SYSTEMS

38 Heating Capacity Data Heating Capacity Data Figure 26: Steam Coil, Low Capacity Figure 28: Steam Coil, High Capacity Figure 27: Steam Coil, Medium Capacity Table 21: Saturated Steam Properties Pressure (psig) Temperature ( F) Latent Heat (Btu/lb.) Table 22: Steam Valve Selection Chart Valve Size (inches) Condensate Rate, lb./hr. Steam Supply Pressurea 5 psig 10 psig 15 psig 25 psig / / / Based on valve pressure drop of 80% of saturated steam supply pressure. CAT ROOFPAK PACKAGED SYSTEMS 38

39 Heating Capacity Data Figure 29: Hot Water Valve Pressure Drop RPE/RDE 076C - 150C Figure 30: Hot Water Valve Piping Pressure Drop RPE/RDE 076C - 150C 39 CAT ROOFPAK PACKAGED SYSTEMS

40 Heating Capacity Data Electric Heat Minimum cfm must satisfy two issues: 1. Maximum temperature rise is 60 F, therefore (minimum cfm = (MBh) (1000) / (1.085) (60). 2. Airflow must not be less than 22,000 cfm regardless of temperature rise. Table 23: Electric Heat Options Model Volt MBh , 575 Volt MBh Table 24: Gas Furnace Design Maximum Air Temperature Rise ( F) and Minimum Air Flow Baffle Position A B C Maximum Temperature Rise ( F) Minimum Airflow (cfm) Furnace Size (MBh) Maximum Temperature Rise Minimum cfm Column Number* Maximum Temperature Rise Minimum cfm Column Number* Maximum Temperature Rise Minimum cfm Column Number* *Column Number for Pressure Drop (See Table 26 on page 41) Table 25: Gas Burner Connection Size (inches) and Gas Inlet Pressure (in. W.C.) Description Minimum Gas Inlet Pressure (In. W.C.) Gas Pipe Connection Size Inches (N.P.T.) Furnace Size (MBh Output) Natural Gas (CFH) Standard Burner :1 Burner Through 0.5 psi psi psi CAT ROOFPAK PACKAGED SYSTEMS 40

41 Heating Capacity Data Table 26: Furnace Pressure Drop (in. W.C.) Airflow (cfm) Column Number (See Table 25 on page 38) *Column Number for Pressure Drop (See Table 24 on page 40) 41 CAT ROOFPAK PACKAGED SYSTEMS

42 Gas Piping Schematic Figure 31: Gas Piping Schematic Vent to atmosphere Gas Piping Schematic *Minimum inlet pressure required varies with model and arrangement, from 5 to 9 inches wc *Low Pressure 9" 14" wc standard 6 20 Modulation option 2 5 Natural gas shown. For LP gas, delete *High Pressure High pressure option required for inlet gas pressure over 0.5 psig Table 27: Gas Piping Descriptions Item Description FM/ETL/UL FM/ETL-C IRI Thru 400 MBh Over 400 MBh Thru 400 MBh Over 400 MBh MBh 1 Forced draft blower Standard Standard Standard Standard Standard 2 Combination air switch Standard Standard Standard Standard Standard 3 Pilot cock Standard Standard Standard Standard Standard 4 Pilot pressure regulator Standard Standard Standard Standard Standard 5 Pilot gas valve Standard Standard Standard Standard Standard 6 Pilot orifice Standard Standard Standard Standard Standard 7 Main gas orifice Standard Standard Standard Standard Standard 8 Manifold pressure tap Standard Standard Standard Standard Standard 9 High pressure switch Standard 10 Test cock Standard Standard Standard Standard Standard 11 Leak test tap cock Standard 12 Safety shutoff valve 13 Vent to atmosphere valve, N/O 14 Safety shutoff valve Combination redundant valve and pressure regulator Standard Combination redundant valve and pressure regulator Standard Standard Combination redundant valve and pressure regulator Standard Combination redundant valve and pressure regulator Safety shut off valve Safety shut off valve with proof of closure switch 15 Low pressure switch Standard 16 Main pressure regulator Combination redundant valve and pressure regulator Standard Combination redundant valve and pressure regulator Standard Standard 17 Main gas shutoff cock Standard Standard Standard Standard Standard High pressure regulator Lubricated shutoff cock Combustion air butterfly valve Main gas butterfly valve Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional 22 Modulating operator Optional Optional Optional Optional Optional Table 28: Gravity Relief Damper Air Pressure Drop 0-100% Economizer Exhaust cfm Size 076C-150C Note: If all exhaust must occur through the economizer gravity relief damper, and no return or exhaust fan is provided, then the building may be pressurized by the sum of the return duct pressure drop plus the gravity relief pressure. CAT ROOFPAK PACKAGED SYSTEMS 42

43 Component Pressure Drops Table 29: Component Pressure Drops Component Pressure Drops Outdoor/Return Air Options 1, 2 Filter Options Plenum Options Component Airflow (cfm) 26,000 30,000 34,000 38,000 42,000 46,000 50, % outside air hood w/damper % outside air hood w/damper Economizer, w/o RAF Economizer, w/raf % pleated Prefilter, standard flow Prefilter, medium flow Prefilter, high flow % cartridge, standard flow % cartridge, medium flow % cartridge, high flow % cartridge, standard flow % cartridge, medium flow % cartridge, high flow Return, isolation damper Discharge, isolation damper Cooling Cooling diffuser Options 3 Cooling coils See Table 30: Cooling Coil Air Pressure Drop Heating Options Hot water, 1-row Hot water, 2-row Steam, 1-row, 6 fpi Steam, 1-row, 12 fpi Steam, 2-row, 6 fpi Electric heat Gas heat See Table 26: Furnace Pressure Drop (in. W.C.) on page Pressure drop through hood and damper is based on 30% of listed airflow. 2. Pressure drop through the economizer assumes that the majority of air will be passing through the return air dampers. If large quantities of outside air are required, pressure drops will increase causing airflow to decrease. 3. A diffuser is provided on units with blow-through cooling coils, final filters or hydronic heating. Table 30: Cooling Coil Air Pressure Drop Unit Size 076C 100C 110C 150C Cooling Coil Airflow (cfm) DX, low airflow, 5-row, 10fpi DX, low airflow, 5-row, 12fpi DX, high airflow, 5-row, 10fpi DX, high airflow, 5-row, 12fpi DX, low airflow, 5-row, 10fpi DX, low airflow, 5-row, 12fpi DX, high airflow, 5-row, 10fpi DX, high airflow, 5-row, 12fpi NOTE: DX coil pressure drops are based on wet coils. Pressure drop of cooling coils not shown can be found in the Daikin selection program output CAT ROOFPAK PACKAGED SYSTEMS

44 Fan Performance Data Return Fans & Exhaust Fans Fan Performance Data Figure 32: All Sizes (2) 36 Propeller Exhaust Fans DO NOT SELECT CLASS II FAN REQUIRED Figure 33: All Sizes (3) 36 Propeller Exhaust Fans DO NOT SELECT CLASS II FAN REQUIRED CAT ROOFPAK PACKAGED SYSTEMS 44

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

Catalog C: RoofPak Singlezone Heating and Cooling Units. Type RPS/RFS/RCS 18 to 135 Tons MEA N. See page 3

Catalog C: RoofPak Singlezone Heating and Cooling Units. Type RPS/RFS/RCS 18 to 135 Tons MEA N. See page 3 Catalog C: 214-5 RoofPak Singlezone Heating and Cooling Units Type RPS/RFS/RCS 18 to 135 Tons MEA 368-93-N See page 3 A New Standard in Rooftop Systems 15 through 135 tons with the flexibility to provide

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

THE ULTIMATE ROOFTOP SOLUTION

THE ULTIMATE ROOFTOP SOLUTION Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Catalog RoofPak Applied Rooftop Systems with Energy Recovery Wheels

Catalog RoofPak Applied Rooftop Systems with Energy Recovery Wheels RoofPak Applied Rooftop Systems with Energy Recovery Wheels Catalog 220-1 Packaged Heating and Cooling Units Type RFS/RPS 15 to Tons Type RDT 45 to Tons Rooftop Air Handlers Type RAH/RDS 4,000 to 30,000

More information

Maverick II Commercial Rooftop Systems 15 to 75 tons

Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems System performance and reliability make Maverick II commercial packaged rooftop systems the ideal solution for

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Catalog 218-2 RoofPak Applied Rooftop Systems Air Handler Type RAH 047C and 077C 12,000 to 50,000 cfm Type RDS 708B, 800C, 802C 2,000 to 20,000 cfm MEA 28-91E, Vol II MEA 147-96E Contents A New Standard

More information

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features: RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Catalog Maverick II Commercial Packaged Rooftop Systems. Engineered for flexibility and performance

Catalog Maverick II Commercial Packaged Rooftop Systems. Engineered for flexibility and performance Maverick II Commercial Packaged Rooftop Systems Catalog 250-6 Heating & Cooling Models MPS015F 075F 15 to 75 Tons R-410A Refrigerant Engineered for flexibility and performance Introduction.................................

More information

Vision and Skyline Semi-custom Air Handlers

Vision and Skyline Semi-custom Air Handlers Vision and Skyline Semi-custom Air Handlers Flexible design solutions to match building applications Skyline Outdoor Air Handler 900 to 65,000 cfm Vision Indoor Air Handler 900 to 100,000 cfm Custom solutions

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM SECTION 23 81 06 - PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes equipment types that contain all the components of the refrigeration process within

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Catalog Rebel Commercial Packaged Rooftop Systems

Catalog Rebel Commercial Packaged Rooftop Systems Catalog 256-11 Rebel Commercial Packaged Rooftop Systems Heating & Cooling Models DPS 003 015 3 to 15 Tons R-410A Refrigerant Energy Recovery Wheel 3 6 tons 7 15 tons with Energy Recovery Table of Contents

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

Technical Development Program

Technical Development Program Technical Development Program PRESENTED BY: James Parker Insert your logo here AIR HANDLERS Coils: Direct Expansion Chilled Water and Heating Menu Section 1 Introduction Section 2 Typical Coil Applications

More information

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters 237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices

More information

Catalog Rebel Outdoor Chilled Water Air Handling Systems

Catalog Rebel Outdoor Chilled Water Air Handling Systems Rebel Outdoor Chilled Water Air Handling Systems Packaged Heating & Cooling Models DAH A03 A21 500 to 11,500 cfm (3 to 21 ft 2 ) Energy Recovery Wheel, Energy Recovery CORE Catalog 571-2 A03 A05 A07 A11

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

ALL PRODUCTS BROCHURE

ALL PRODUCTS BROCHURE ALL PRODUCTS BROCHURE www.aaon.com d e d i c at i o n t o cust o m e r service since the founding of aaon in 1988, we have maintained our commitment to design, develop, manufacture and deliver heating

More information

Cultivator & Hybrid Cultivator

Cultivator & Hybrid Cultivator Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models T-Class Performance and rugged durability Commercial Split Systems Up to 20-Ton TSA/TPA Models Up to.7 EER Lennox units deliver comfort and control you can depend on Lennox proven design in air conditioners

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and

More information

Catalog Rebel Commercial Packaged Rooftop Systems

Catalog Rebel Commercial Packaged Rooftop Systems Catalog 256-13 Rebel Commercial Packaged Rooftop Systems Heating & Cooling Models DPS 003 028 3 to 28 Tons R-410A Refrigerant Energy Recovery Wheel 3 6 tons 7 15 tons Shown with Energy Recovery 16 28 tons

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable

More information

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Commercial Packaged Rooftop Systems

Commercial Packaged Rooftop Systems Competitively priced rooftop systems for one to three story buildings Commercial Packaged Rooftop Systems Engineered for flexibility and performance McQuay Commercial Rooftop Systems System performance

More information

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models UP TO.7 EER Lennox units deliver comfort and control that you can depend on The latest offerings from Lennox represent a new design in air conditioners

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum

More information

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant. Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers Models RCS 015D to 140D R-410A Refrigerant Catalog 222-5 Introduction.... 3 The Condensing Unit for Applied Rooftop and Air

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Direct Gas-Fired Make-Up Air Models DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons Your Chiller Solution For Efficiency And Reliability McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons McQuay Dual Compressor Centrifugal Chillers Superior part load efficiency, reliability

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects VariCool VAV (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water Unique Solutions for All-Indoor HVAC Projects Water Source Heat Pump Water-Cooled Chilled Water Modular

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

RHEEM PACKAGE GAS/ELECTRIC

RHEEM PACKAGE GAS/ELECTRIC INDEX ACCESSORIES... 4-2 SAMPLE SPECIFICATIONS... 4-2 RKNL (3-5 TON) SERIES... 4-6 RKNL-B (6-12.5 TON) SERIES... 4-7 RKNL-B (15-25 TON) SERIES... 4-8 RKNL-C (6-12.5 TON CLEAR CONTROL ) SERIES... 4-9 RKNL-C

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals

More information

RT-OA TM Rooftop Outdoor-Air (DOAS)

RT-OA TM Rooftop Outdoor-Air (DOAS) RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...!

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS 48/50HG HIGH-EFFICIENCY SERIES The Centurion Rooftop GAS/ELECTRIC, 12.5 25 TONS ELECTRIC/ELECTRIC, 12.5 25 TONS INDUSTRY-LEADING EFFICIENCY PLUS ADVANCED COMFORTLINK CONTROLS Advanced IAQ features that

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

Mission Critical Air Conditioning Systems

Mission Critical Air Conditioning Systems Mission Critical Air Conditioning Systems wall & ceiling mount Series 7 & 11 1-5 Ton Units Single Circuit Units Designed for Superior Space Utilization Series 7 1.5-2.5 tons Compact wall mounted split

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1: 4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This

More information

C-Series. Unique Solutions for All-Indoor HVAC Projects

C-Series. Unique Solutions for All-Indoor HVAC Projects C-Series 1 to 15 tons Horizontal Self-Contained or Split Systems Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Unique Solutions for All-Indoor HVAC Projects

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components. Page 238126-1 SECTION 238126 - This Section includes requirements for the LEED Rating System. However, equipment specified in this Section may not qualify for LEED Rating System prerequisites and credits.

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information