NORDYNE has received reports of malfunctioning TXV valves in ton split systems and package units.
|
|
- Theodore Merritt
- 5 years ago
- Views:
Transcription
1 To: Residential Distributors and Dealers Aftermarket Distributors and Dealers From: Technical Service Department Date: September 9, 2014 RE: POE Oil Contamination Ton Split Systems and Package Units (Revised) NORDYNE has received reports of malfunctioning TXV valves in ton split systems and package units. As reported in earlier bulletins, a sticky substance has been found in the TXV that has been identified as coagulated ester based lubricant (POE Oil). This issue has been wide-ranging and has affected our entire industry. NORDYNE has worked closely with Emerson Climate Technologies to identify a date range of suspect product. The targeted date range (of the compressor bearing unit) is between October 1, 2013 September 1, Serial Number date code XXX XXX1409 NORDYNE has worked with a limited number of Distributor TSA s in testing an oil additive (NuCalgon AC Re-New / Zerol Ice) in systems demonstrating contaminated TXV s. In our sample units the malfunctioning event was corrected. NORDYNE is allowing in systems that are demonstrating contaminated TXV operation (as evidenced by high or fluctuating superheat after a successful start-up) the application of NuCalgon AC Re-New / Zerol Ice. This will eliminate the need to replace the TXV and drier. Please see attached AC Re-New instructions or follow this link: HVAC best practice system testing must be done to confirm the malfunction is not system charge related or a failed TXV for other mechanical reasons such as control bulb charge loss. NORDYNE Bulletins are not for public display, web posting, or dissemination to non-nordyne partners. NORDYNE distributors may post the bulletin ONLY behind a secure fire wall that requires password access, and where the folder cannot be crawled by web search engines Phoenix Parkway O Fallon, Missouri NORDYNE. All Rights Reserved.
2 NORDYNE will cover the application of this additive through warranty. The coverage includes reimbursement for the additive NORDYNE SKU (4 oz. liquid) or SKU (6 oz. pressurized) and 2 hours standard labor ($150.00). When entering the claim please reference this bulletin number in the work performed. All claims must include the compressor bearing unit serial number. SKU numbers for NuCalgon AC Re-New oz AC Re-New (unpressurized) oz AC Re-New (pressurized) Ac Re-New Injector Tool (not covered by warranty, any oil or dye injector tool can be used). Should it be necessary to replace the TXV and drier due to POE Oil contamination, normal warranty applies including 4 hours standard labor ($300.00) for units in the above identified date range. This bulletin must be referenced in the work performed, and the failed TXV must be returned to: NORDYNE 2800 Hoff Road Dyersburg, TN The returned TXV must be clearly marked with the unit serial number, claim number and this bulletin number. If you have any questions please contact NORDYNE Technical Service at Thank You NORDYNE Technical Service NORDYNE Bulletins are not for public display, web posting, or dissemination to non-nordyne partners. NORDYNE distributors may post the bulletin ONLY behind a secure fire wall that requires password access, and where the folder cannot be crawled by web search engines Phoenix Parkway O Fallon, Missouri NORDYNE. All Rights Reserved.
3 Nu-Calgon Product Bulletin 3-80 REVITALIZES AND ENERGIZES AIR CONDITIONING SYSTEMS UNIVERSAL PACAKAGE PERMITS USE WITH ALL REFRIGERANTS. Refrigeration Oil A/C Re~New Quiets noisy compressors. Reduces energy consumption. Improves heat transfer in the evaporator and condenser. Great for new and old systems. Description A/C Re~New has been used successfully for many years to improve the performance of air conditioning and refrigeration systems. A/C Re~New provides significant saving in energy use. It also quiets noisy systems and extends the life of the system. It is a lubricant that blends with the system s oil, lasting for the life of the equipment. A/C Re~New in the Compressor PP PP PP Improved lubricity through reduced friction drag Cleaner system Quieter Operation Application A/C Re~New can be used in air conditioning and refrigeration applications. The pressurized package, , is formulated for use in R-22, R-410A as well as other refrigerants in systems up to 5 tons. Multiple cans should be used to treat larger commercial systems such as packaged units or larger refrigeration systems. Additionally, the product is available in unpressurized 4 oz. bottles and 32 oz. quarts. Install with the A/C Re~New Injector. Packaging Pressurized can start-up kit quart (32 fl. oz.) fluid ounce can A/C Re~New Injector Tool Injection Valve Altom Ct. St. Louis, MO Calgon is a licensed trade name (714) 3-80
4 A/C Re~New Technology Testing Results Residential air conditioning systems account for up to 70% of the home s energy consumption. And when the outdoor temperature rises the system works longer and harder. Through tests on actual installations, the A/C Re~New technology has demonstrated its ability to reduce the air conditioning systems energy use on average by 11% It has also been found to improve the system s cooling performance and quiet noisy systems. Energy Savings Number of units tested Outdoor Temperature Average Running amps Before A/C Re~New Average Running amps After A/C Re~New % Savings ºF 56.4ºF % 5.2% Noise Reduction Average Decibel Before A/C Re~New Average Decibel After A/C Re~New Decibel Drop Cooling Performance Average Air Duct Temp. Before A/C Re~New Average Air Duct Temp. After A/C Re~New Temperature Drop 57.4ºF 54.2ºF 3.2ºF Falex Pin Test This test is used to evaluate wear and tear, friction and extreme pressure properties of materials and lubricants. A rotating pin, also referred to as a journal, is lubricated with the test product and is compressed between two V-shaped blocks. Pressure (depicted by the red arrows) is added at increasing levels until the pin fails. The goal is to determine how much load or force the lubricant can withstand before it fails. Therefore, the higher the load, the better the lubricant. Three typical industry oils (Mineral Oil, Alkylbenzene and POE) were tested, both alone and then mixed appropriately with A/C Re~New. A/C Re~New significantly improved the oil s load-to-failure points. BRASS LOCKING PIN JOURNAL V-BLOCKS Compressor Wear Test This test evaluated how well A/C Re~New reduced metal wear in operating compressors. Six reciprocating compressors were tested with R-22 refrigerant and mineral oil for a period of 500 hours. A/C Re~New was applied to half of the compressors. As shown in the pictures to the right, the bearing wear on the compressors was significantly reduced in those compressors containing A/C Re~New. Less wear means the equipment will last longer and reduced friction results in lower energy consumption. Similar results were achieved in scroll compressors (photos available). Reciprocating - Upper Journal Without A/C Re~New With A/C Re~New Fewer Scars
5 Directions for Use For R-22 systems and other systems where the low side pressure is below 65 psi: One can will treat systems up to 5 tons Multiple cans should be used to treat larger commercial systems such as packaged units, split systems, etc 1. Confirm that you have all the required items for the application. 2. Use one can of A/C Re~New for up to 5 tons of system capacity. For larger systems, multiple cans should be used. And for system capacities that fall between multiples of 5 tons (3 tons, 7 1/2 tons, etc.), round up to the next multiple of 5 tons to determine the required charge of A/C Re~New. For example, use two cans to treat 7 1/2 tons. The slightly higher dose of A/C Re~New is nominal and considered acceptable. 3. Oil removal. For systems over 10 tons, it is recommended that 4 fluid ounces of system oil be removed for every 5 tons of capacity. For example, remove 12 fluid ounces of oil from a 15 ton system, and install three cans of A/C Re~New. 4. Be sure to exercise and use good air conditioning, refrigeration service practices at all times. 5. Close Injection Valve, and attach it to the can of A/C Re~New. 6. Connect one end of the charging hose to the Injection Valve, and then connect the other end of the hose to an access port on the low pressure side. 7. Slightly crack the hose fitting connected to the Injection Valve in order to purge air from the hose. Then, quickly re-tighten fitting. 8. With can upright, open the Injection Valve and allow the A/C Re~New mixture to charge into the system. The A/C Re~New is pressurized sufficiently to overcome low side system pressures below 65 psi. Charging will take 2-3 minutes. 9. If additional cans are to be added, leave hose connected but close Injection Valve. With Injection Valve closed, remove it from the spent can. (Be careful as can will be under some pressure.) Attach new can of A/C Re~New and open Injection Valve to inject product. Repeat for all additional cans. 10. Close Injection Valve, then follow by disconnecting both ends of hose. Remove Injection Valve. 11. Retain hose and Injection Valve for future A/C Re~New applications. 12. Properly discard the empty A/C Re~New can. For R-410A systems and other systems where the low side pressure is ABOVE 65 psi while running: IMPORTANT: System must be pumped down to lower the low side pressure to psi. Since low side pressures in a R-410A system are higher than the pressure in the A/C Re~New can, you must first pump down the system to inject the product. To do so, follow the below instructions. 1. Secure electric power to the unit and connect the refrigerant manifold, as shown in Figure Close the liquid line valve and turn the compressor on to start pumping refrigerant into the condenser. 3. Operate the compressor until the suction gauge on the manifold shows a pressure of 40 to 50 psi (lower pressure than what is in the can). CAUTION: Do not pump completely down as low pressure cut-off or high pressure relief could engage. 4. When the pressure on the suction gauge is between 40 and 50 psi, turn the compressor off and immediately close the suction line valve. This procedure traps most of the refrigerant in the condenser allowing you to inject the A/C Re~New. (Be sure the pressure in the low side is between 40 and 50 psi) 5. Shake can well. Be sure piercing valve handle is turned fully counter clockwise and then attach piercing valve to can. Be sure not to cross thread or over tighten. 6. Attach other end of charging hose to low side service port. As this is done, there will be a very small release of system charge that will purge air from the hose. Additionally, where permissible by law, the hose can be purged by slightly unscrewing the piercing valve from the can allowing the system s charge to enter and purge the hose. CLOSED LOW METERING VALVE EVAPORATOR HIGH CLOSED SUCTION LINE VALVE DISCHARGE SERVICE VALVE FIGURE 2 CONDENSER LIQUID LINE VALVE
6 7. Turn piercing valve handle fully clockwise to pierce can then, turn piercing valve handle counter clockwise to open valve and install A/C Re~New. Allow approximately 2-3 minutes for product to completely enter the system. 8. Once product is dispensed, close piercing valve and remove hose from low side service port. 9. After the charging hose is disconnected from the system, open the valves to allow the refrigerant back into the rest of the system. Run the system continuously for 1 hour or more to allow product to fully circulate through system. 2 Open Briefly to Purge Hose Open Briefly to Purge Hose 1 Instructions for Using the A/C Re~New Injector Tool A/C Re-New A/C Re-New If desired, the unpressurized packages may be used. This includes the 4 fluid ounce bottle ( ) and the quart A/C ( ). Re-New Use of the A/C Re~New Injector Tool ( ) is recommended for installation. Secure hose-end A/C LOW to Re-New SIDE suction side fitting, with valve in closed position. Once attached, crack valve quickly to purge. 3 Installing A/C Re~New 4 b) Open Slightly to Pressure Canister a. Attach a vacuum pump to the other end, as shown, using another short hose with a shut-off valve. Draw vacuum on extra hose, then close its valve. Proceed to step 4. b. b) As Open an alternative method Slightly without to the vacuum pump, use a clean manifold hose set and Pressure proper service techniques Canister to push the A/C Re~New into the low side with high side pressure. Be sure to purge or burp LOW all SIDElines. b) Open Slightly to Pressure Canister a. Attach to high side and then briefly open valve on second hose to pressurize the cylinder of product. Close valve. b. Slightly open valve on cylinder to push product into system low side. SIDE to cylinder and the close cylinder lid to seal. b) Open Slightly to 5 Once installed, close this valve and disconnect from low side fitting. Pressure Canister 6 Close up cylinder to prevent any contamination from entering it. Read and understand the product s label and Material Safety Data Sheet ( MSDS ) for precautionary and first aid information. The MSDS is available on the Nu-Calgon website at Altom Ct. St. Louis, MO Calgon is a licensed trade name (714) 3-80
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationThe complete approach to the care and management of A/C & refrigeration systems
The complete approach to the care and management of A/C & refrigeration systems Testing oil with the Phase III Refrigeration Oil Acid Test Kit Flushing with OEM endorsed R x 11-flush Acid removal with
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationTechnical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:
Technical Review of a Remote Condenser Cuber with Enhanced Refrigeration and Water Systems using CM 3 Technology models included are: CME1356 shown on BH900 CME456, CME1056, CME1356, CME1656 and CME2006
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationOperation and Maintenance Manual
Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which
More informationRecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual
RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4
More informationA/C-HEATER SYSTEM - MANUAL
A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,
More informationSERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume
More informationOtherwise, you can continue reading the file on the following pages.
If you d like to be able to print this file out to study off-line or use on the job, a printable version is available for an administrative fee of $3.97 USD. To download the unlocked file, click here.
More informationPRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56
INSTALLATION Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56 INSTALLATION Table of content Introduction...4 Preparation before installation...5 Vehicle partition... 6 Box preparation...7
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20
More informationA/C SYSTEM GENERAL SERVICING
A/C SYSTEM GENERAL SERVICING 1988 Jeep Cherokee 1988 AIR CONDITIONING & HEAT A/C General Servicing Diagnostic Procedures Eagle & Jeep * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning
More informationENSPECO Recovery/ Recycle/ Evacuate/ Recharge
ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover
More informationRefrigerant changeover guidelines
Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC
More informationXC13. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R410A.
Service Literature Corp. 0521 L9 Revised 09 2007 XC13 SERIES UNITS XC13 The XC13 is a high efficiency residential split system condensing unit, which features a scroll compressor and R 410A refrigerant.
More informationInstallation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Cased Coil Conversion 4 System Start-Up 17 TXV CCS-410-KIT
More informationR100 Oil-Less Refrigerant Recovery Unit
R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines
More informationINSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA
TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,
More informationSHOWCASE. Spring Maintenance FREE PRODUCTS 2% OFF $1,500 WITH CASE QTY PURCHASE OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS ANY ORDER OF OR MORE!
Spring Maintenance SHOWCASE NO MINIMUM ORDER EFFECTIVE 3/15-5/31 2% OFF ANY ORDER OF $1,500 OR MORE! WITH CASE QTY PURCHASE FREE PRODUCTS OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS MOTORS 2 CHEMICALS
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL RLV-700 REFRIGERANT RECOVERY / RECYCLING UNIT (PATENTED) NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 (215) 638-8909 FAX (215) 638-9270 REVISED 03-21-2018
More informationRecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual
RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual (English) Table of Contents Page General Safety Instructions...2 System Overview...3 RecoverX-CAR Operation
More informationPublication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration
More informationReference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.
GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant
More informationMYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationAPPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)
4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationModel K / K. Modelo K / K. Modèle K / K. Operating Manual
Operating Manual Model 34800-2K / 34801-2K Recovery/Recycling/Recharging Unit for R-12 and R-134a Refrigerants... English Modelo 34800-2K / 34801-2K Unidad de recuperación/reciclaje/recarga para refrigerantes
More informationInstallation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT
EarthLinked TXV Kit Installation Manual for Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT CONTENTS PAGE Pre-Installation 3 Hydronic Water Module Conversion
More informationSERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS
Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE
More informationXSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationBulletin , March Electric Hot Gas Bypass Valves
Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital
More informationOwner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit
Owner s Manual Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Model AC375C Recover, Recycle, and Recharge Unit for R-12 or R-134a Refrigerant Voltage: 220 230; 50 60 Hz SAFETY DEFINITIONS:
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Self-Contained Flaker Model F-330BAH(-C) A Superior Degree of Reliability INSTRUCTION MANUAL www.hoshizaki.com Issued: 5-4-2007 Revised: 1-15-2013 WARNING Only qualified service
More informationHEATING AND AIR CONDITIONING
WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT
More informationInstallation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Air Handler Conversion 4 System
More informationMASS. MARITIME ACADEMY
MASS. MARITIME ACADEMY REFRIGERATION LAB OUTLINE Rev.3 Fall 2015 Table of Content Page Lab #1: Introduction to refrigeration system components, tools and procedures 1 Lab #2: Familiarization, operation,
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC
AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act
More informationSERVICE BULLETIN A
1. PLANNING INFORMATION A. Effectivity: Dassault Falcon 10 aircraft which have installed R-134a Upgrade Kit SZ59K-R134 before August 8, 2002. B. Reason: Upgrade kits before August 8, 2002 did not include
More informationUser information. Cleaning/descaling and sanitizing
User information How the dispenser works Follett s 110 series automatic-load ice and water dispensers are equipped with Follett s 425 lb (193 kg)/day ice machine. In the continuous icemaking process, water
More informationSEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS
148 OLD CONCORD TURNPIKE BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH
TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationCondensing Unit Installation and Operating Instructions
Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.
More informationFrigi Tech International, Inc Prairie Wind Lane,. Houston, Texas T: F:
Education at your fingertips There is the misconception that t an air conditioner blows cold air when actually it removes the heat from the conditioned space. Let s start trtwithwhtwe re what we re all
More informationNovember 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES
November 2006 / BULLETIN -60 ELECTRIC DISCHARGE BYPASS VALVES PAGE 2 / Bulletin -60 10 FEATURES AND BENEFITS Direct temperature control Tight shutoff when closed Can be interfaced with direct digital controls
More informationINSTALLATION INSTRUCTIONS
2016 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Elite Series XC16 Units AIR CONDITIONER 507161-01 8/2016 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE General This
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Modular Crescent Cuber Models KM-900MAH50 KM-900MRH50 A Superior Degree of Reliability INSTRUCTION MANUAL www.hoshizaki.com Issued: 6-25-2008 IMPORTANT Only qualified service technicians
More informationRejuvenation Instructions
Rejuvenation Instructions #402 Air Systems iupr & SPR Trademarks: http://www.novinium.com/trademarks/ Patents: http://www.novinium.com/patents/ This NRI covers the following: Novinium, Inc. engineering@novinium.com
More informationM1200 Series Limited Warranty Dependability Promise
M1200 Series Limited Warranty Dependability Promise Warranty effective for equipment manufactured after January 1, 2011 Dear Customer, Congratulations on your decision to purchase the most reliable heating
More informationEnspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS
Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Merit Series 13ACX Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service
More informationG Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton
G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1
More informationMortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS
Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph
More informationResidential Piping and Long Line Guideline
AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC
AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More information13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.
Service Literature Corp. 0612 L2 Revised 07 2006 13ACX SERIES UNITS 13ACX The 13ACX is a high efficiency residential split system condensing unit, which features a scroll compressor and designed for R
More informationOperating Manual for. Model Recovery, Recycling, Recharging Unit
Operating Manual for Model 34988 Recovery, Recycling, Recharging Unit Model 34988 Recovery, Recycling, & Recharging Unit SAFETY DEFINITIONS: Follow all WARNING, CAUTION, IMPORTANT, and NOTE messages in
More information13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.
Service Literature Corp. 0612 L2 Revised 06 2007 13ACX SERIES UNITS 13ACX The 13ACX is a high efficiency residential split system condensing unit, which features a scroll compressor and designed for R
More informationariazone 601HD Refrigerant Recovery & Recycling Unit User's manual
ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual Model: Ariazone 601 HD Serial No: 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before operating
More informationOPERATION & MAINTENANCE MANUAL AC860
OPERATION & MAINTENANCE MANUAL AC860 Refrigerant Handling System Manual P/N 035-80913-00 TABLE OF CONTENTS Startup & Safe Operation... 1 Introduction to the AC860... 2 Control Panel... 3 Keypad Functions...
More informationThe Essentials Of Working With R-410A
The Essentials Of Working With R-410A By Norm Christopherson Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of 410A continues
More informationSECTION 50 - CAB CLIMATE CONTROL
AIR CONDITIONING SYSTEM DYNAMIC DESCRIPTION The refrigerant circuit of the air conditioning system contains five major components: Compressor, Condenser, Receiver/Drier, Expansion Valve, and Evaporator.
More informationInstallation Instructions
Split System Indoor Coils Installation Instructions! CAUTION: Read the Installation Instructions supplied with furnace/air handler and observe all safety requirements outlined in instructions and/or furnace/air
More informationAIR CONDITIONING. Carrier Corporation 2002 Cat. No
AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)
More informationInstallation Instructions
Split System Indoor Coils Installation Instructions CAUTION: Read the Installation Instructions supplied with furnace/air handler and observe all safety requirements outlined in instructions and/or furnace/air
More informationPRO 2000i LOW LEVEL DEPOSITOR
DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)
More informationTC-720 RECYCLING BALER
OPERATING AND MAINTENANCE INSTRUCTIONS TC-720 RECYCLING BALER READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING Sept. 06, 2013 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com
More informationOperating Manual, Model K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1
Operating Manual, Model 348002K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1 Refrigerant Recovery, Recycling and Recharging Station Series: 348002K/348012K Refrigerants:
More information1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below:
SUPER SEAL HISTORY Work on Super Seal leak sealants for residential and commercial systems began in August 1999, after the successful introduction of Cliplight's Super Seal Pro, for automotive systems.
More informationRefrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate
More informationINSTRUCTIONS! DO NOT DISCARD!
INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION
More informationAutomotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD
Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD - Automotive A/C Service Station 1 Contents Page 1. Introduction... 3 2. Safety firts... 4 3. Technical Features...
More informationMulti zone Two, Three, Four and Five Zones
MULTI SPLIT SYSTEM OUTDOOR UNITS SERVICE MANUAL Multi zone Two, Three, Four and Five Zones DC INVERTER MULTI ZONE OUTDOOR UNITS Revision A: ODMI E 1601 PDB55/2016 Model Numbers: YN020GMFI22M2D YN030GMFI22M3D
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationHP13 WARNING WARNING. Service Literature HP13 SERIES UNITS
Service Literature Corp. 0610 L1 Revised 07 2006 HP13 SERIES UNITS HP13 The HP13 is a high efficiency residential split system heat pump unit, which features a scroll compressor. HP13 units are available
More informationINSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA
TXV Coils EDM, EDD, EDA These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system to
More informationOPERATION & MAINTENANCE MANUAL TX600
OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page
More informationBLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.
OWNER S MANUAL BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC. PROPER FREON USAGE The below list shows the correct Freon usage for each Sno-Block B-220-SB MP-220-SB 409-220-SB 414-08-SPB 404-08-SPB B-440-SB
More informationTo accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.
Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs the unwanted heat, this raises the refrigerant
More informationOperating Letter. Operating Letter #730 January 1, 2014 WARRANTY AND TECHNICAL SERVICE
Operating Letter #730 January 1, 2014 WARRANTY AND TECHNICAL SERVICE NO HASSLE REPLACEMENT LIMITED WARRANTY PROGRAM PURPOSE Establish procedures for filing warranty claim when a unit is replaced under
More informationLiebert Prop Fan Condensing Unit
Liebert Prop Fan Condensing Unit 50 Hz and 60 Hz Installer/User Guide Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section of this
More informationSTERI-VAC CENTRAL SUCTION SYSTEM
STERI-VAC CENTRAL SUCTION SYSTEM INSTALLATION MANUAL This is a general installation manual for Steri-Vac Central Suction Systems. For detailed information see specific technical sheet. These are high-volume
More informationOwner s Manual. Terpene Trap CF 1000
Owner s Manual Terpene Trap CF 1000 IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to use your Terpene Trap. For your safety, comply with all safety instructions and
More informationTSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton
Service Literature Corp. 0903 L1 Revised: March 2011 TSA SERIES UNITS TSA 6, 7.5, 10, 12.5, 15 & 20 ton The TSA units are designed for light commercial applications, with a remotely located blower coil
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationInstallation Instructions
24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationCME256, 506, 656, 806: AutoIQ Cubers
Introduction: CME256, 506, 656, 806: AutoIQ Cubers This product manual contains the information needed for the setup, installation, initial start up, sanitation and maintenance of this ice machine. Keep
More informationWARRANTY LABOR CLAIM
True Manufacturing 2001 East Terra Lane O Fallon, MO 63366-4434 Phone#636-240-2400 855-878-9277 Fax#636-980-8510 warrantyclaims@truemfg.com WARRANTY LABOR CLAIM INSTRUCTIONS FOR COMPLETING FORM: 1. Model
More informationSECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING
SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING UNIT OBJECTIVES After studying this unit, the reader should be able to Select the correct instruments for checking an air conditioning unit
More informationHS25 SERVICE UNIT INFORMATION
SERVICE UNIT INFORMATION HS25 Corp. 9327-L3 Litho U.S.A. HS25 SERIES UNITS The HS25 is a high efficiency residential split system condensing unit which features a scroll compressor. It operates much like
More informationRLD-H10G Refrigerant Leak Detectors
FANs 125, 121 Product/Technical Bulletin RLD-H10G Issue Date 0396 RLD-H10G Refrigerant Leak Detectors The RLD-H10G is a professional grade leak detector for use by refrigeration and air conditioning technicians.
More informationUSING R-134A REFRIGERANT
USING R-134A REFRIGERANT HANDLING/SAFETY PRECAUTIONS 1998 GENERAL SERVICING General Servicing Procedures 1. Always work in a well-ventilated, clean area. Refrigerant is colorless and invisible as a gas.
More informationThomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.
Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration
More informationPERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE
PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1966-67 PLYMOUTH BELVEDERE CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect Fit system. Offers complete comfort capabilities in virtually every
More informationInstallation Instructions
Split System Indoor Coils Installation Instructions CAUTION: Read the Installation Instructions supplied with furnace/air handler and observe all safety requirements outlined in instructions and/or furnace/air
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationSymphony Plus Pressurized Water Sanitizing Kit P/N
For use with systems with no filter Symphony Plus Pressurized Water Sanitizing Kit P/N 01089580 Installation Instructions ATTENTION! These instructions are for Symphony Plus dispensers only. Instructions
More informationEarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions
EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 10 Antifreeze Protection 14 Electrical
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD
TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More information