Operating and assembly instructions Heat pump with air duct for service water heating WPA 302 E-LF

Size: px
Start display at page:

Download "Operating and assembly instructions Heat pump with air duct for service water heating WPA 302 E-LF"

Transcription

1 Operating and assembly instructions Heat pump with air duct for service water heating WPA 302 E-LF To be passed on to the user!

2 Table of contents... Page 1. Introduction Customer service Intended use Technical data Functional description Refrigerant circuit (functional principle of the HP) Water heater (boiler) Additional electric heating rod Safety elements of the heat pump Operating conditions Storage tank connection Filling the system with water Condensate drainage Electrical installation Circuit diagram Commissioning of the heat pump Operating procedure of the heat pump Brief operating instructions Operating programs Parameter display Installation site of the heat pump Duct pipe system Connection of the duct pipe system Advantages of the heat pump with air duct Various combinations of service water heating Notes on safety Instructions for secure up-keep Transport and storage Disassembly and decommissioning Notes on safety Elimination of technical defects Guarantee, warrantee and product liability

3 1. Introduction We would like to thank you for the trust you put in us by purchasing our heat pump. We are convinced that the device will render good services, so that both you and we are satisfied. This small brochure will provide you with any important information for correct assembly and operation. However, still have your dealer explain the function of the device and demonstrate its operation to you. Of course you may also consult our customer service and sales department. Please read any information contained in these instructions carefully prior to commissioning the device. Safely store these instructions and pass them on to subsequent owners, if applicable. Upon reading the operating instructions, particularly observe chapters marked with this warning sign. This sign refers to particularly important text passages in certain chapters. Furthermore, this sign is located next to all other symbols and labels, which refer to possible risks. 2. Customer service Services and elimination of defects during the guarantee period will be rendered by Austria AG. When ordering spare-parts for the device, please always state the following: Product Product type Serial number Year of construction Any data required for ordering spare-parts are provided on a label or sticker at the device. 3. Intended use This heat pump is intended for water heating in residential or other buildings, where the daily demand for hot water does not exceed 700 liters. During service water heating, the heat pump simultaneously cools the room, where it is installed. The intended use of the heat pump, beside high energy savings during water heating, thus also is the cooling of a selected room (e.g. basement, storeroom, etc.). In case of any modifications at the device, unauthorized interference or exchange of the original components, the manufacturer no longer accepts any liability for the safety and functionality of the device. In case of inappropriate and incorrect use, any guarantee and liability is rejected on the part of the manufacturer in the event of damage. 3

4 4. Technical data Product: Heat pump with air duct for service water heating Type: WPA 302 E-LF Maximum power input: 520 W / 2020 W* Maximum heat output: 1660 W / 3120 W* Maximum performance: 680 W (60 C) Heating rod*: 1500 W Voltage: 230 V ~ 50 Hz Fuse protection: 16 A (230 V / 50 Hz) COPt (EN255/3): 3,2 Refrigerant: R134a Heat exchanger performance: 15 kw Maximum hot water temperature: 55 C / additional heating to ~ 60 C Required air throughput: 500 m 3 (8-35 C) Protection class: IPX1 Maximum pressure in the storage tank: 6 bar (0,6 Mpa) Maximum temperature in the storage tank: 75 C (heating rod limiter) Ambient temperature: 7-35 C Sound pressure level: 52 db(a) Maximum pipe duct length: 10 m Connecting piece: ø 150 mm (d1) Connection: R1 (circulation: R3/4 ) Minimum room height: 2200 mm 5. Functional description Water heating using a heat pump is an environment-friendly and efficient way of hot water supply in buildings. The model WPA 302 E-LF is a compact unit with an aggregate (compressor, evaporator, ventilator, ) and a water heater. The hood of the heat pump consists of polyethylene and has two pipe sockets for connection to a duct pipe system. The heat pump likewise offers the possibility of ventilation of a selected room. The aggregate of the heat pump consists of: compressor, evaporator, centrifugal ventilator, dry filter, copper and electrical installation. In the aggregate of the heat pump, the entire thermo-dynamic process for water heating in the storage tank takes place. 4

5 1. HP CW Cold water connection 2. Storage tank HW Hot water connection 3. Air connection CL Circulation 4. Air connection HEI Pipe register supply 5. Boiler circulation pump HEO Pipe register return el. connection 6. Magnesium anode 7. Ext. sensor duct 8. Heating rod d1 9. Pipe register 10. External heat exchanger HW 6 CL 7 8 HEI H e d c b HEO CW 9 10 a Adjustable feet D k Dimensions in mm Contents Overall weight Tip dimension H ød A B C D E 300 liters kg

6 5.1 Refrigerant circuit (functional principle of the HP) The refrigerant circuit is a closed system, wherein the refrigerant R134a circulates as the energy carrier. In the lamellar heat exchanger, the heat is extracted from the sucked in air at a low evaporation temperature and transferred to the refrigerant. The vaporous refrigerant is sucked into a compressor, compressed to a higher pressure and temperature level, and transported to the condenser, where the heat taken up in the evaporator and part of the absorbed compressor energy are passed on to the water. Subsequently, the high condensation pressure is relieved using a throttle element (expansion valve) down to the evaporation pressure, and in the evaporator, the refrigerant can take up heat from the sucked in air again. 5.2 Water heater The water heater is double-vacuum-enameled on the inside, polyurethane-foamed on the outside, and encased with steel sheet. For bivalent heat-pump operation, a heat exchanger is installed in series in connection with the boiler. Additionally, an installed protective anode prevents corrosion damage in case of a possible damage to the enamel coating on the inside of the boiler. 5.3 Additional electric heating rod The installed electric heating rod EH with outputs of 1.5 kw or 2.0 kw serves for: Fast water heating For that, heat pump and heating rod work simultaneously. Protective function of the evaporator In case of the temperature being too low, the electric heating rod is automatically switched on, if the heat pump is set to summer operation. Alternative heating For example, in case of an operating failure of the aggregate. 5.4 Safety elements of the heat pump Frost protection sensor The heat pump has an air temperature sensor installed, which measures the air flowing through the evaporator, and at 7 C switches off the heat pump for 30 minutes. For heat pumps with an electric heating rod, this is switched on in summer operation, as soon as the air temperature drops to below 7 C. In winter operation, at this air temperature, the circulation pump of the connected boiler is switched on. Operating and safety thermostat of the electric heating rod The electric heating rod has an operating and safety thermostat installed, which is set to a temperature of 65 C. Attention! With the electric heating rod in operation, the water is always heated to approx. 65 C, since only the upper area of the hot water tank is heated. In this case, the controller does not indicate the actual water temperature, because its sensor is inserted in the lower area of the hot water tank, and in this case measures a lower water temperature. The safety thermostat switches off at 75 C and must be reset manually. Control of the hot water temperature in the hot water tank The OPTITRONIC controller serves controlling and heating the water to the desired temperature. Depending on the desired water temperature, the controller switches the compressor and ventilator off or on. In certain cases, the controller also switches the electric heating rod or the circulation pump of the heating boiler on or off. The maximum water temperature to be set is 55 C; upon actuating the shortcut button HT, the water temperature is 60 C. 6

7 High-pressure pressure control (HD) The high-pressure pressure control protects the heat pump against inadmissibly high operating pressures in the refrigerant circuit. In case of an incident, the pressure control switches off the heat pump. The heat pump is automatically restarted following pressure reduction in the refrigerant circuit. For that, the following is displayed: >E7<. 5.5 Operating conditions The ambient temperature for normal use is to be between +7 C and +35 C. The air must be clean and the relative air-humidity should not exceed 50 % at +40 C air temperature. In case of lower ambient temperatures, a higher relative air-humidity is permitted, too. Assembly must not take place at an altitude of more than 2000 m. For systems used at an altitude of more than 1000 m, heating as well as air cooling performance are reduced due to the air pressure. Under no circumstances may the heat pump be installed in places in which the air could contain pollutants or toxins (stables, storage rooms for hazardous materials, in the open air etc.). 5.6 Storage tank connection The connection to the water line must be executed according to the regulations applicable to the connection of water heaters. The following figure shows how the water line is connected. The maximum pressure in the water line must not exceed 6.0 bars. 1. Pressure reduction valve 2. Return valve 3. Shut-off valve 4. Safety valve 5. Expansion tank 6. Drain valve Connection of the HP to the water line 7 Adjustable feet

8 The bare-tube heat exchanger has to be professionally flushed prior to execution of the initial installation (we furthermore recommend the installation of a dirt filter). If the bare-tube heat exchanger is not used upon operation of the storage tank (e.g. heat pump only), then it has to be completely filled with a respective glycol mixture in order to avoid corrosion caused by the resulting condensation water. In that, following filling, the filled bare-tube heat exchanger must not be closed at both ends (pressure expansion with temperature). 5.7 Filling the system with water Following connection of the heat pump to the water line, the system has to be completely filled with water. Only when the water exits at the extraction point without forming bubbles, the system has been filled and completely vented. The heat pump must never be commissioned without water in the boiler there is the risk of damage to the compressor! 5.8 Condensate drainage Due to moisture in the air, condensation water is formed in the heat pump. Depending on season and hot water demand, this is about 1 to 5 liters per day. This condensation water may, e.g., be used for a steam iron or for watering plants. In order to drain the condensation water, a discharge hose is attached to the device, which is located at the right-hand rear of the device. Attention: There is a check valve installed in the end of the hosepipe, which may only be removed if a siphon is fitted. If in the installation room, free discharge of the condensation water is not possible, a collection tank with a capacity of at least 10 liters must be provided for this reason. Attention: In case longer air ducts are used, it is absolutely indispensable to install a non-return valve at the lower end of the condensate pipe for correct condensate drainage and non-transmission of the tap odor. 1. Drainage hose; 2. Collection container or drain pipe; 3. Ceck valve 5.9 Electrical installation Once the heat pump has been connected to the water line and properly filled and vented, electrical connection may be undertaken. The connecting cable must only be plugged into an earth contact-type socket (16 A, 230 V / 50 Hz). 8

9 5.10 Circuit diagrams Circulation pump Heating rod 230 V AC 50 Hz Compressor Ventilator S1: Pressure control T1: Hot water temperature sensor T1: Ambient air temperature sensor Electrical circuit diagram L - brown N - blue Earthing L N Circulation pump of auxiliary heating (boiler) Terminals for the circulation pump (boiler) in the terminal box (max. 300 W). 9

10 5.11 Commissioning of the heat pump Modern and visually simple representation of the information about the operating condition via display and control lamp Shortcut buttons for water temperature setting (+, -) Shortcut button for switchover of the operating mode (P) Shortcut button HT for one-time water heating to 60 C (anti-legionella protection) Possibility for fast water heating (heat pump and additional heat source) Automatic switchover to the spare heat source upon cooling of the ambient temperature (boiler or electric heating element) Anti-Legionella program with automatic water heating to 60 C at intervals of 14 days Self-diagnosis Identification and display of operating errors Operating procedure of the heat pump With the heat pump properly connected to the power and water supply, the controller version of the set operating program or >P1<, respectively, is displayed on the screen after 2 seconds, as well as all parameters and their values. 30 seconds following electrical connection, the system starts up and starts heating the water. The heat pump is switched on. Once the pre-set switch-off temperature of 52 C has been reached, the heat pump switches off automatically. As soon as the water has cooled by 5 C, i.e. to 47 C, the heat pump is switched on again. The switch-off temperature may be chosen by the user, however, is limited to a maximum of 55 C (temperature controller blockage). Water heating to 60 C is restricted to this value and is not adjustable. The ambient air temperature, at which switch-over to the spare heat source takes place, has already been set to 7 C. This temperature can be randomly set by the user (instructions in the following) Brief operating instructions Display of the selected mode of operation/program Water temperature display Switch-over to summer/winter mode of operation Shortcut button for one-time water heating to 60 C (anti-legionella protection) Setting of the water temperature and parameter display The display on the operating panel in the basic menu shows the current water temperature in the storage tank. 10

11 Functional description Flashing display: Flashing display not illuminated not illuminated illuminated not illuminated not illuminated illuminated not illuminated flashing illuminated illuminated illuminated flashing Particularities flashing flashing or illuminated Selected program P0 P1 P2 P3 (WPK 301 LF) P4 P5 (WPK 301 LF) P4, P5 Description The heat pump is switched off and only the water temperature display in the storage tank is active. The heat pump is heating the water to the set temperature with the compressor only. The heat pump heats up the water. With the air temperature being too low, the compressor is switched off for reasons of safety. Attention: In case of a defective air sensor, this error is indicated, but the water is still heated further. The hot water temperature set is only heated with the heating boiler. Comment: The air temperature has no influence on the function. The hot water temperature set is heated using an electric heating rod. Comment: The air temperature has no influence on the function. The heat pump is heating the water to the set temperature with the compressor (automatic mode of operation). The heat pump is heating the water depending on the air temperature. If the switchover temperature is undercut, the heat pump automatically switches over to heating with the heating boiler. The heat pump is heating the water to the set temperature with the compressor (automatic mode of operation). The heat pump is heating the water depending on the air temperature. If the switchover temperature is undercut, the heat pump automatically switches over to heating with the electric heating rod. In case of switchover to the spare heat source (P4 and P5 only). If the air temperature is too low or if the switchover temperature was undercut, for program P4, the water is heated with the heating boiler, for program P5, with the electric heating rod. For that, the compressor is switched off for reasons of safety. Comment: Upon actuating the >P< button, the selected program is displayed (the selected program can also be controlled via the flashing display see table above). With each further pressing of the >P< button, various available programs can be selected within 8 seconds. Attention: With each selected program, the heat generator is selected, too, which takes over water heating. 11

12 1. Setting of the hot water temperature: Upon pressing the >+< or >-< buttons, the currently set water temperature is displayed. With each subsequent actuation (within 8 seconds), this, however, may be changed. 5 seconds after the flashing has stopped, the new setting is saved. 2. Switchover between various modes of operation: Switchover between the modes of operation is performed using the >P< button. The selected mode of operation is displayed with illumination of the mode of operation indicator and the inscription with the first pressing of the >P< button (see table above). With each subsequent actuation of the >P< button within 8 seconds, the available modes of operation may be changed. Recommendation: If the ambient temperature is above 7 C, it is reasonable to heat the water with the heat pump only (P1, P4, P5). 3. One-time thermal disinfection: The one-time water heating to 60 C is switched on with the HT button. The indicator on the button illuminates until the end of the water being heated. Pressing the HT button again, the heating process can be stopped early. We recommend an interval of 14 days, which should not be undercut, since the energy consumption is higher by approx. 1/3 than with normal operation of the heat pump. Water heating is performed using the heat source, which was set and selected with the mode of operation (e.g. P1 compressor, P2 boiler). Should the heating not take place within 12 hours, the function is switched off and over to normal water heating. 4. Faster water heating: With programs P4 or P5, the function of fast (simultaneous) water heating is available, for which both heat sources are operated (heat pump and electric heating element in program P5, heat pump and boiler in program P4). This function is switched on with the HT button by keeping it pressed for 20 seconds. The indicator of the HT button flashes until the set water temperature has been reached. The function can be stopped early by pressing the HT button again Operating programs 1. Water heating with the compressor only (P1): The water is heated until either the set temperature is reached or the ambient temperature drops below the set value. If the hot water is cooling down by 5 C, the compressor starts the heating process again. If the ambient temperature is cooling to below the set value, the compressor is switched off for 30 minutes or until a higher ambient temperature is reached, respectively, for safety reasons. 2. Water heating with the boiler only (P2): The water is heated by the circulation pump of the boiler until the set temperature is reached. If the water is cooling down by 5 C, the circulation pump is switched on again automatically. 3. Water heating with the electric heating element only (P3): The operating and safety thermostat of the electric heating element is set to 65 C, switches off upon reaching the water temperature of the heating element, and independently switches on again when the water temperature is dropping. Since the sensor is located underneath the electric heating element, the temperature displayed for a heating element installed at the top may deviate from the set temperature. 4. Water heating with the compressor and automatic switchover to the spare heat source upon undercutting of the air temperature (P4 and P5): The heat pump automatically works in compressor operation until the set water temperature has been reached or the ambient temperature has been undercut, respectively. If the ambient temperature drops below the set value, the controller automatically switches over to heating with the spare heat source (P4 heating with boiler, P5 heating with electric heating element). During heating with the spare heat source, the indicator is flashing. After 30 minutes, at the latest, or when the ambient temperature is increasing again, the controller switches back to heating using the compressor. 12

13 Parameter display Pressing the >+< and >-< buttons simultaneously, the parameter menu is displayed. These two buttons also serve scrolling in the menu. 8 seconds after the desired parameter has been selected, its value is displayed for 10 seconds, then the display returns to the main menu, which shows the current water temperature in the storage tank. Parameter Designation Range Factory setting L0 Display of the ambient air temperature in C - 9 to + 95 L1 Switch-off air temperature in C 5 to 30 7 L2 Time interval of automatic water heating in days 1 to Setting of the time interval of automatic thermal disinfection/safety heating (60 C): In order to enter the menu of parameter display, press the >+< and >-< buttons simultaneously. These buttons subsequently also serve scrolling in the menu. Select parameter L2; after a few seconds, the pre-set heating interval (14 days) is displayed. During the display of the set value, this can be changed at random (from 1 to 99 days) using the >+< and >-< buttons. 5 seconds after the desired setting, the flashing stops and the settings are saved. It is recommended to perform the water heating once within 14 days. Heating the water too often is not recommended due to the increased energy demand (1/3 higher). 2. Temperature setting of switchover to the spare heat source (>P4< and >P5< only): In order to enter the menu of parameter display, simultaneously press the >+< and >-< buttons. Subsequently, these buttons also serve scrolling in the menu. Select parameter L1; after a few seconds, the switch-off temperature (set to 7 C) is displayed. During the display of the set temperature, it can be changed at random (from 5 to 25 C) using the >+< and >-< buttons. 5 seconds after the desired setting, the flashing stops and the settings are saved. A temperature setting of below 7 C is not recommended due to icing of the evaporator. 13

14 6. Installation site of the heat pump The heat pump may be installed in any room, except for the living space. The room may have any size, but it must at least be large enough for the installation of the heat pump (approx. 20 m³). The minimum room height must be 2200 mm. Under no circumstances may the heat pump be installed in places in which the air could contain pollutants or toxins (stables, storage rooms for hazardous materials, in the open air etc.). The heat pump is designed such that it sucks in the air for ventilation via the duct pipe system from the room or from the environment. The air sucked in passes on its heat to the heat pump and is then, depending on requirements, wishes and demand, returned to the selected room or the environment. The heat pump enables the following types of ventilation, which depend on the design of the duct pipe system: Suction from the room blowing out into the same or a remote room Suction from the adjoining room blowing out into the same adjoining room (cooling of the adjoining room) 14

15 Suction from the adjoining room blowing out into the same adjoining room (laundry drying) Suction from the room blowing out into the environment Suction from the environment blowing out into the environment Suction from the environment blowing out into the same or a remote room The most frequent duct pipe system design is the one where air from rooms with high waste heat is sucked in and transferred into the heat pump, which usually is installed in the basement. From this air, part of the heat is extracted, and the air is subsequently blown out to the environment. Air from bathroom, kitchen, toilet, etc. frequently contains odors and is therefore blown out to the environment. 6.1 Duct pipe system The duct pipe system should be designed such that the air does not change its direction of flow on its way, if possible. The duct length between the suction connection and the blow-out connection should not exceed 10 m. If the direction of flow is changed frequently, this has to be considered as additional air resistance, and the duct length should be respectively shortened. Thus, a 90 bend means a pipe duct shortened by 0.5 m. In the same manner, all closure elements (flaps, filters, ventilation valves) must also be considered in the duct pipe system. The pressure drop in the pipe duct being too high reduces the air flow. If the air temperature is below +10 C, this may cause slow icing of the evaporator and thus worse ventilation, wherein something like that is hardly noticed. 15

16 It is necessary to install at least one 90 pipe bend in order to avoid air mixture between the air ducts respectively sucking in and blowing out. Min. 0,6 m Max. 10 m Min. 1,2 m Min. 0,6 m Min. 0,8 m Min. 1,2 m 6.2 Connection of the duct pipe system The figure shows the cover of the heat pump. The cover has two supports, which are 40 mm high and have an outer diameter of Ø 150 or Ø 160 mm. The access to the interior parts of the heat pump is covered with a safety guard, which must not be removed. Suction Blowing out Deckel der WPA 302 E-LF mit ø 150 mm Rohrstutzen 16

17 6.3 Advantages of the heat pump with air duct The heat pump with air duct has a number of advantages over the standard compact version and also over the design with a separate evaporator. The heat pump may be installed in any room, which is sufficiently large for it. The heat pump enables ventilation of a selected room. The heat pump enables discharge of the room air as well as supply of fresh air from the environment. When selecting the room, consider the diameter and the height of the heat pump. Above the device, there must be sufficient space for the pipe duct connections. The minimum distance to the walls is 0.5 m. 6.4 Various combinations of service water heating The service water can be heated in various ways. The combination of heat pump and boiler is called bivalent operation, for which during the coldest days of winter, beside the living space, the water, too, is heated with the boiler. Alternated heating of the service water with the heat pump in summer and with the boiler in winter. 17

18 Post-heating of the service water with the boiler in the HP boiler Post-heating of the service water with the solar plant 18

19 7. Notes on safety The device must only be operated by the specialist company and respectively instructed persons, who via these operating instructions guarantee safe operation and maintenance. It is prohibited to move or relocate the device as well as to clean or repair it during operation. Prior to installation and any later access to the interior of the device, make yourself familiar with the contents of the operating instructions for safe operation and maintenance in any case. The electrical installation of the device must be performed by an authorized person (certified electrician) with the device in a completely discharged state. It is prohibited to relocate the heat pump and to lean any objects against the heat pump. Around the heat pump, there must be sufficient space for fast and easy access for repair and maintenance. If during heat pump operation the water temperature in the boiler rises to above 75 C, the customer service must be informed in any case. Disconnect the device from the power supply prior to any work at the heat pump. The heat pump must be installed such that the power plug is freely accessible at any time. The device must be erected on a stable, level and non-slippery floor. An area of at least 2 m² must be ensured for operation. During installation, operation and maintenance, sufficient illumination of the heat pump should be given, which should be at least 150 luces. It must be ensured that the device poses no risk for anybody, and that children as well as unauthorized persons cannot gain access during operation. 8. Instructions for secure up-keep Upon compliance with these instructions for use for safe operation and up-keep, the heat pump will work without additional servicing and maintenance. Recommended inspections: An inspection of the magnesium anode for protection of the water heater should be undertaken every two years. Inspection of the safety valve at the cold water connection unscrew the valve a little until the water is flowing. Inspection of the evaporator lamellas the lamellas must not be covered in dust, since this gradually reduces the performance of the heat pump. Should the lamellas be covered in dust, switch off the heat pump, unscrew the screws, remove the upper plastic cover, and clean the lamellas with a vacuum cleaner or blow air through the lamellas. In that, observe that the lamellas or other parts of the heat pump are not damaged. Following commissioning, the heat pump should not be decommissioned for longer than 1 month, as this can result in the failure of the lubrication for the compressor piston, which can render the heat pump inoperable. If this results in damage then the manufacturer shall exclude any claims against the guarantee. 19

20 Inspections prior to a damage report to the customer service: Check, whether everything is fine with the electrical connection lines. Check, whether the air outlet from the evaporator is obstructed by the grids. Measure the temperature in the room where the heat pump is installed and check, whether it lies within the range of specified temperatures. The device must be connected in compliance with the national regulations. 9. Transport and storage During transport, the heat pump is protected with a protective film and cardboard packaging in order to prevent damages like impressions and scratches. Following transport, the device must stand upright for at least 2 hours, so that the distributed refrigerant flows back to the compressor. The device must only be relocated or moved when it is not in operation. The admissible temperature during transport and storage lies between 10 and 45 C, wherein in the short term up to 24 hours, up to 55 C are admissible, too. The heat pump must not be positioned horizontally under any circumstances. 10. Disassembly and decommissioning The device as a whole, according to its technical concept design, has a lifetime of several years. Individual components, however, may also be exchanged in case of possible interferences, wear and mechanical damage. In case of repair, only original spare-parts must be used. Following decommissioning, the device must be disposed of at a landfill for industrial waste according to its waste classification. Components hazardous to the environment must be disposed of at a respectively specified collection point. 11. Notes on safety The device was produced based on technical standards, which enable the manufacturer to attach the CE marking on the device. As a warning against possible risks upon operating the heat pump, the device has been equipped with respective signs and symbols (pictograms). The meaning of the signs and symbols (pictograms) can be retrieved from the following figures. 20

21 Carefully read the operating instructions Risk of an electric shock The device must not be positioned horizontally. Transport and use in an upright position. Besides symbols (pictograms) and signs, a further label or sticker is attached to the device, containing the technical data of the device. 12. Elimination of technical defects Warning display Aerate the room so that it warms up to the correct temperature A1 A3 Switch-off of the HP due to the ambient temperature being too low Switch-off of the HP, because the ambient temperature exceeding the highest limit value of 37 C Set the switch-over temperature of the spare heat source to a lower value In case of connection to a boiler, switch over operation to P2 or P3. Heating takes place automatically by the boiler or heating rod. Aerate the room so that the temperature drops below this value If the temperature in this room is constantly above this value, another installation site should be chosen Error indication Cause Solution E7 Alternating E8 and -- Alternating E8 and -- Pressure in the system too high Water temperature sensor not connected Water temperature sensor damaged Check, whether there is enough water in the storage tank Using the >+< button, the error is deleted. If the error occurs again, call customer services Check, whether the sensor is connected or call customer services, respectively First reset the HP. Check sensor connection or sensor cable, respectively. If the error occurs again, call customer services. 21

22 Alternating E9 and -- Air temperature sensor not connected correctly Check, whether the sensor is connected or call customer services, respectively Alternating E9 and -- Description of the problem Water is not heated up to the set temperature HP constantly running / not switching off HP causes a lot of noise Heating rod not effective Evaporator freezing Air temperature sensor damaged Cause Boiler heating circuit for service water heating not closed Circulation looses too much heat There is a gas leak somewhere in the system Evaporator damage due to careless cleaning Too little gas in the system Circulation looses too much heat Uncontrolled heat loss from the boiler (hot water consumption too high) The ventilator touches the housing or the safety guard Compressor damage (fixing spring damage) The condenser touches the boiler exchanger Controller shows temperature below the heating rod, therefore the display temperature is lower Temperature in the storage tank exceeding 75 C, safety thermostat switched off Air flow too small Ventilator damage Temperature in the room of air recording too low First reset the HP. Check sensor connection or sensor cable, respectively. If the error occurs again, call customer services Solution Close the valve for the boiler heating circuit Switch off the pump and close the valve of circulation Call customer services Call customer services Call customer services Switch off the pump, close the valve for the circulation Check any possible discharges from the boiler Call customer services Check, whether the tapping water is warm Reset safety thermostat Air inlet and outlet must be free Call customer services Set the switchover temperature to the higher value 22

23 Warranty, Guarantee and Product Liability The warranty is granted in accordance with the statutory provisions of the Republic of Austria, as well as of the EU. 1. Prerequisite for the provision of warranty services by Austria AG (hereinafter referred to as AE AG) shall be the presentation of the paid invoice for the purchase of the device for which the warranty service is claimed, whereby the identity of the device with regard to the model and the manufacturing number must be evident from the invoice and must be documented by the claimant. The General Terms and Conditions, Terms and Conditions of Sale and Delivery of AE AG shall apply exclusively. 2. To the extent required by the law, respectively in the Operator s Manual and Installation Instructions, the assembly, erection, connection and commissioning of the unit for which the claim is presented must have been carried out by a licensed electrician or installation firm, duly observing all applicable rules. The tank (without outer shell and plastic outer shell) must be protected from sunshine to avoid discolouring of the PU foam and potential warping of plastic components. 3. The room in which the device is operated must be free of frost. The unit must be mounted in a location that may reasonably be expected, i.e. it must be possible to access and replace the unit without difficulty for the purpose of necessary maintenance, repairs and possible replacement. The costs for any necessary changes to the structural conditions (e.g. doors and passages too narrow) are not governed by the guarantee and warranty declaration and therefore shall be rejected on the part of AE AG. If the water boiler is set up and operated in uncommon locations (e.g. attics, living rooms with water-sensitive floors, store rooms, etc.), the possibility of water leakage must be taken into account and provisions made for collecting and discharging the water leakage in order to prevent secondary damage within the meaning of product liability. 4. The following is not covered by the warranty and guarantee: inappropriate transport, normal wear and tear, intentional or negligent damage, use of force of any kind or description, mechanical damage or damage caused by frost or also by exceeding the operating pressure stated on the rating plate, even if only once, use of connection fittings that do not comply with the standard, use of defective tank connection fittings and unsuitable and defective service fittings. Breaking of glass and plastic components, possible colour differences, damage due to improper use, in particular non-observance of the mounting and operating instructions (Operating and Mounting Instructions), damage by external influence, connecting to incorrect voltage, corrosion damage as a consequence of aggressive waters (water not suitable for drinking) in accordance with the national regulations (e.g. Austrian ordinance on drinking water, TWV Fed. Law Gazette II No. 304/2001), deviations between the actual drinking water temperature at the tank fitting and the specified hot water temperature of up to 10 K (hysteresis of the controller and possible cooling due to pipelines), Insufficient water conductivity (min. 150 µs/cm), operational wear of the magnesium anode (wearing part), natural formation of boiler scale, lack of water, fire, flood, lightning, overvoltage, power failure or other types of force majeure. Use of non-original and company-external components such as e.g. heating elements, reactive anode, thermostat, thermometer, ribbed tube heat exchanger, etc., ingress of foreign particles or electrochemical influences (e.g. mixed installations), failure to observe the design documents, unpunctual and undocumented renewal of the installed protective anode, no or improper cleaning and operation, as well as any deviations from the standard that reduce the value or functionality of the device only slightly. Fundamental compliance with all regulations in ÖNORM B 2531, DIN 1988 (EN 806), DIN 1717, VDI 2035 or the corresponding national regulations and laws must be ensured. 5. In the case of an authorised complaint, this must be reported to the next available customer service location of AE AG. The same reserves the right to decide whether a defect component shall be replaced or repaired or whether a defect device shall be replaced by an equivalent fault-free device. Furthermore, AE AG explicitly reserves the right to request that the rejected device be returned by the buyer. 6. Repairs under warranty must be performed exclusively by persons authorised to do so by AE AG. Replaced parts shall remain the property of AE AG. If a repair of the hot water heater should be required in connection with necessary service work, the Manufacturer shall invoice these as repair and prorated material costs. 7. Any intervention by third parties without our express instruction, even if performed by a licensed electrician, shall have the effect of voiding the warranty. Costs for repairs carried out by third parties shall be replaced only if AE AG has previously been requested to remove the defect and if AE AG shall have failed to satisfy its obligation to replace the defective item or repair the defect or if it shall have failed to do so within a reasonable period of time. 8. Neither the performance of works under warranty or guarantee, nor the performance of service and maintenance works shall renew or extend the term of warranty. 9. Transport damage shall be investigated and possibly accepted only if it is reported to AE AG in writing on the next following workday after delivery at the latest. 10. Claims over and above the warranty, if legally permissible, in particular claims with respect to compensation of damages and consequential damages, shall be excluded. Prorated labour time for repairs as well as the costs of restoring the original condition of the unit must be paid in full by the buyer. In accordance with this warranty declaration, the warranty shall apply only to repair or replacement of the unit. The provisions of the Terms and Conditions of Sale and Delivery of AE AG shall, unless amended by these Terms and Conditions of Warranty, remain fully in place. 11. Services that are not performed within the scope of these Terms and Conditions of Warranty shall be charged. 12. No claims under warranty shall be considered by AE AG unless full payment for the device has been made to AE AG and unless the claimant has fully satisfied all obligations arising to him vis-à-vis the seller. 13. The enamelled internal boiler for water heaters is warranted for the specified period from the delivery date provided all warranty terms described under Points 1 to 12 are observed with in full. If the warranty terms have not been met, the legal warranty requirements of the respective country from which the appliance was shipped shall prevail. 14.With regard to the assertion of claims pursuant to the Austrian Product Liability Act it must be noted: Potential claims under the title of product liability relating to the regulation of damages due to a defective product (e.g. a human s body is injured, his health is damaged or any corporeal property differing from the product is damaged) shall only be justified if all the prescribed measures and requirements for flawless and normal operation of the unit have been fulfilled. These include e.g. the mandatory and documented anode replacement, the connection to the correct operating voltage, any damage due to improper use must be avoided, etc. These standards are based on the assumption that if all the regulations (standards, assembly and operating instructions, general guidelines, etc.) are observed, the defect in the unit or product causal for occurrence of the secondary damage would not have occurred. It is further imperative that all the documentation necessary for handling of a claim, such as e.g. the type and fabrication number of the unit, the vendor s invoice and the invoice of the licensed electrician or installation firm, as well as a description of the malfunction be provided, as well as the defective unit itself for examination in the lab (absolutely necessary, as the unit will be investigated by an expert and the cause of the defect analysed). In order to exclude any possibility of mistaken identity of the unit during transportation, the unit must be labelled with a clearly legible label (ideally with the end customer s address and signature). Appropriate photographic documentation of the extent of damage, the installation (cold water inflow, hot water outflow, heating inflow and outflow, safety fittings, expansion vessel if applicable), as well as the defective part of the tank is required. AE AG further expressly reserves the right to demand the submission of documentation and units or unit components by the buyer for the purpose of clarification. The damaged party s full burden of proof that the damage was caused by the product of AE AG is prerequisite for the payment of any benefits under the title of product liability. Claims for damages pursuant to the Austrian Product Liability Act are moreover justified only for any amount exceeding the amount of 500 euros (deductible amount). Until all the facts and circumstances as well as the problem causally underlying the defect have been ascertained, any possible fault on the part of AE AG shall be ruled out explicitly. Any non-observance of the operating and assembly instructions as well as the relevant standards shall be deemed negligence and shall result in an exclusion of any liability for damages. The figures and data are not binding and may be amended without notice in the interest of technical improvement. Misprints and technical changes reserved. 23

24 Headquarters and plant: Austria AG A-8720 Knittelfeld, Austriastraße 6 Tel.: (03512) 700-0, Fax: (03512) Internet: office@austria- .at Addresses of the sales branches: Vienna, Lower Austria, Burgenland A-1230 Wien, Zetschegasse 17 Tel.: (01) Fax: (01) bhrastnik@austria- .at Styria, Carinthia, East Tyrol A-8053 Graz, Am Wagrain 62 Tel.: (0316) Fax: (0316) gbretterklieber@austria- .at Upper Austria, Salzburg A-4600 Wels, Gärtnerstraße 17 Tel.: (07242) Fax: (07242) akweton@austria- .at Tyrol, Vorarlberg A-6020 Innsbruck, Etrichgasse 24 Tel.: (0512) Fax: (0512) hruepp@austria- .at

Operating and Installation Instructions

Operating and Installation Instructions Operating and Installation Instructions Ribbed pipe heat exchanger RWT Please forward this on to the user! Technology that makes you feel good Id.No.: 179390-3 The heating coils are suitable for the heating

More information

Following your decision to purchase a hot water heater with an electric storage tank produced by our company,

Following your decision to purchase a hot water heater with an electric storage tank produced by our company, General connection and warranty conditions Layer-buffer storage tanks PZ - PZR - PZRR 500-800 - 1000-1500 litres Please pass on to the end user Dear Customer, Following your decision to purchase a hot

More information

Operating and Mounting Instructions

Operating and Mounting Instructions Operating and Mounting Instructions EBH-KDW EBH-TDW Please pass on to the user! Dear customer! The built-in electric heaters are manufactured in accordance with the applicable regulations. The installation

More information

General Terms and Conditions of Connection and Warranty

General Terms and Conditions of Connection and Warranty General Terms and Conditions of Connection and Warranty Buffer tank PSRPSRR PSM PSF Please pass on to the user. Dear customer! You have chosen a buffer tank produced by our company for water heating. We

More information

General Terms and Conditions of Connection and Warranty

General Terms and Conditions of Connection and Warranty General Terms and Conditions of Connection and Warranty Buffer Tank Please pass on to the user. Dear customer! You have chosen a buffer tank produced by our company for water heating. We thank you for

More information

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 USER S MANUAL VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125 VKMz 150 VKMz 160 VKMz 200 Q VKMz 200 VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 Centrifugal inline fan VKMz CONTENTS Contents... 2 Safety requirements...

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Operating manual List of contents, Operating manual Page 1. General information... 02 2. Device description... 03 3. Adjustment

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

FHA 1100 A1 Domestic Water Pump

FHA 1100 A1 Domestic Water Pump FHA 1100 A1 Domestic Water Pump Translation of original operation manual 6 Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. / Translation

More information

EN Z Subject to change due to technical improvements! Operating instructions

EN Z Subject to change due to technical improvements! Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature differential controller 3 inputs, 1 output These operating instructions are part of the product. Read

More information

USER S MANUAL DN-2. Drain pump

USER S MANUAL DN-2. Drain pump USER S MANUAL DN-2 CONTENTS Safety requirements... 2 Purpose... 3 Delivery set... 3 Technical data... 3 Design... 4 Installation and set-up... 5 Connection to power mains... 8 Storage and transportation

More information

Decentralised ventilation units

Decentralised ventilation units Notes on installation Decentralised ventilation units FSL / SCHOOLAIR GB/en TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de

More information

Operating instructions

Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Differential Controller inputs, 1 output These operating instructions are part of the product. US Read

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT C-250 - C-400 - C-600 INSTRUCTION MANUAL ICE CUBES MACHINE (including: exploded views, part list & diagrams) Art.no.: *706.025 / *706.040 / *706.060 1 CONTENTS PRECAUTIONS... 2 INSTALLATION... 3-4 OPERATION...

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL ELECTRIC WATER HEATER TO - 20 Družstevní závody Dražice-strojírna s.r.o. (Works Cooperative - Dražice - Machine Plant, Ltd.) Dražice 69, 294 71 Benátky nad Jizerou tel.:

More information

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3 GUARANTEE CERTIFICATE Date of assembly Stamp and signature of the fitter GUARANTEE VOUCHER 1 GUARANTEE VOUCHER 2 GUARANTEE VOUCHER 3 GUARANTEE VOUCHER 4 GUARANTEE VOUCHER 5 Cat. no. Factory no. Date of

More information

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002 Operation Manual for Drying Storage Cabinet with Drying Unit U-5002 (software version 4-09 and above) Aplicable to the following cabinets: MSD-601-52, MSD-1202-52, MSD-1222-52 HSD-241-52, HSD-351-52, HSD-472-52,

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

Installation manual Operating instructions

Installation manual Operating instructions WIKORA GmbH Friedrichstr. 9 89568 Hermaringen Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Operating instructions DHW storage tank UNO/DUO/H/WPSOL Installation

More information

ENAMELED INDIRECT WATER HEATERS

ENAMELED INDIRECT WATER HEATERS INSTRUCTIONS ENAMELED INDIRECT WATER HEATERS ST-300DE HEAT PUMPS Please read this manual carefully before installing the heater! Dear Customer, Sinclair Corporationt Ltd. thanks you for your decision

More information

Operating instructions

Operating instructions Operating instructions for Winterhalter Gastronom dishwasher GS 502 and GS 515 Contents Page 1 Intended use... 1 2 Installation and commissioning... 1 3 Safety instructions... 2 4 Operating panel... 3

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY User Manual EN DECLARATION OF CONFORMITY 2 TABLE OF CONTENTS 1. USAGE...5 2. UNPACKING AND HANDLING...5 3. INSTALLATION...5 4. ELECTRICAL CONNECTION...6 5. START-UP AND OPERATION...7 6. MAINTENANCE AND

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

Installation manual Mini Comfort 50 S/L 07/ V EN

Installation manual Mini Comfort 50 S/L 07/ V EN Installation manual Mini Comfort 50 S/L 07/2015 - V 1.1 - EN www.veneco-ventilation.be Veneco ventilation by Elek Trends Productions nv Blauwfazantjesstraat 4 B - 7700 Moeskroen Tel. +32 (0)56 48 15 90

More information

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL FIRE CONTROL PANEL MAG2/4 USER MANUAL AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 READ THIS MANUAL BEFORE CONNECTING THE EQUIPMENT AND KEEP IT SAFE FOR FUTURE REFERENCE. To call our technical support

More information

OPERATING INSTRUCTIONS FOR:

OPERATING INSTRUCTIONS FOR: OPERATING INSTRUCTIONS FOR: MODEL: BL-30 & BL-130 REFRIGERATED BATH Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill Park DC

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

MeacoDry ABC Range Dehumidifiers

MeacoDry ABC Range Dehumidifiers MeacoDry ABC Range Dehumidifiers Thank you for choosing Meaco, we really do appreciate it INSTRUCTION MANUAL [EN] MeacoDry ABC range SAFETY INFORMATION ATTENTION This dehumidifier must not be used in rooms

More information

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN Table of contents Notes regarding the operating manual... 1 You can download the current version of the operating manual and

More information

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 TEMPERATURE ALTERNATIVES 3 PACK CONTENTS 4 PRE-INSTALLATION INFO 5-6 FAUCET INSTALLATION 7 ADJUSTING

More information

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2 CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2 STUART MANUFACTURING 1 Jayelem Crescent Padstow NSW 2211 Australia Telephone (02) 9773 3711 Fax

More information

Operating Manual. VIENNA Hot Display

Operating Manual. VIENNA Hot Display Operating Manual VIENNA Hot Display Operating and Maintenance instructions Please read this manual carefully before you start to operate your heated display case. Following these instructions helps you

More information

MODULAR AUTOMATIC GRANULAR ICE FLAKER

MODULAR AUTOMATIC GRANULAR ICE FLAKER MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! A120407 V4/0713 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about

More information

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Mobile Air Conditioner Instruction Manual Model TC-N9KM Mobile Air Conditioner Instruction Manual Model TC-N9KM Please read and retain these instructions for future reference SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air

More information

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT 145x210mm 单黑 君 2017.5.4 OWNER S MANUAL THERMOSTAT WHOLE ROOM RADIATOR HEATER Model: HO-0221 PLEASE READ AND SAVE THESE INSTRUCTIONS 1 IMPORTANT INSTRUCTIONS WARNING! When using electrical appliances, basic

More information

AUTOMATIC GRANULAR ICE FLAKER

AUTOMATIC GRANULAR ICE FLAKER AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a

More information

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty OWNER'S GUIDE Gas Continuous Flow Water Heaters Owner's Information Warranty Models 16NG50-6/16LP50-6 16NG60-6/16LP60-6 20NG50-6/20LP50-6 20NG60-6/20LP60-6 26NG50-6/26LP50-6 26NG60-6/26LP60-6 Thermann

More information

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTALLATION, COMMISSIONING AND OPERATING MANUAL INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical

More information

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6 AE PV Heating Element Screwing in Heating Unit Installation Manual Version 01.6 Title Type of Documentation Purpose of the Documentation Publisher Legal Reservation Copyrights AE PV Heating Element Warm

More information

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6 List of contents 1.0 Uses 2.0 Technical data 2.1 Operating data 2.2 Construction and installation 2.3 Climatic load 2.4 Power supply 3.0 Function and design 3.1 General comments 3.2 Design 3.3 Performance

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A Installation Manual Add-on Controller Installation Kit NPE-180A/210A/240A This device is designed to work with NPE-180A/210A/240A water heaters ONLY. WARNING All Installations should be done only by a

More information

Ventilation and air conditioning QUALITY FOR LIFE. Refrigerating systems and heat pumps. Operating manual

Ventilation and air conditioning QUALITY FOR LIFE. Refrigerating systems and heat pumps. Operating manual Ventilation and air conditioning QUALITY FOR LIFE GB Refrigerating systems and heat pumps Operating manual Refrigerating systems and heat pumps 3052967 I 07/2010 Refrigerating systems and heat pumps Table

More information

INSTANT WATER HEATER INSTANO 1L / 3L (Litre)

INSTANT WATER HEATER INSTANO 1L / 3L (Litre) Plot No. 15, Institutional Area, Sector 32, Gurugram - 122 001 Haryana, Tel: +91-124-4583100, Fax: +91-124-4583200, E-mail: usha_care@ushainternational.com, Website: www.usha.com Registered Office: Surya

More information

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is

More information

Instruction Manual. Chest Freezer MODEL: KI130CF2

Instruction Manual. Chest Freezer MODEL: KI130CF2 Instruction Manual Chest Freezer MODEL: KI130CF2 INSTALLATION INSTRUCTIONS Before Using Your Freezer Remove the exterior and interior packing. Check to be sure you have all of the following parts: Storage

More information

Operation regulations must be strictly obeyed.

Operation regulations must be strictly obeyed. General This manual will help the user to operate this equipment safely and correctly. Correct operation of this air drier will reduce maintenance costs and extend the working life of all systems and parts

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport braces Water connection depending on model The washing machine is heavy

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual Suggestions for the hydraulic integration of chillers and heat pumps Table of Contents From practical experience, for your practical needs...

More information

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0 Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL Manual v1.0 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE And neither are we. Always at the forefront of our industry, our

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! Rimi 700220 V3/0214 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 18 1.1 Information

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL STATIONARY ELECTRICAL HOT WATER TANKS OKCE 100 NTR/2,2 kw OKCE 125 NTR/2,2 kw Družstevní závody Dražice - strojírna s.r.o. Dražice 69, 294 71 Benátky nad Jizerou Phone.:

More information

User Manual WMF Cup&Cool WMF Cup

User Manual WMF Cup&Cool WMF Cup coffee wakes up the world User Manual WMF Cup&Cool WMF Cup Add-on Equipment English bistro! 2000S presto! 1400 prestolino! 1300 Model Series 9018 / 9019 Order Nr. 33 0916 1000 Edition 04.2010 General Information

More information

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. CONTROL PANEL... 9 5.1

More information

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased

More information

AUTOMATIC MODULAR ICE FLAKER

AUTOMATIC MODULAR ICE FLAKER AUTOMATIC MODULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 08 It is strictly forbidden to reproduce this instruction manual or any part thereof. 1 5 3 4 Mod. N. V. W 2 2 M8 18 8 18 M8 M8 3 ~ 200

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! 200065 V2/0614 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about

More information

4 liter Solo and 8 liter Combi

4 liter Solo and 8 liter Combi 4 liter Solo and 8 liter Combi User and installation guide for the water heater 2 ENGLISH The HotSpot boiling water tap With the purchase of the HotSpot boiling water tap you can be sure that you have

More information

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Silent TS. Nr / Ideas for dental technology / A. Made in Germany Silent TS Nr. 2921-0050 / 2921-1050 21-9191 30102012 / A Made in Germany Ideas for dental technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Silent TS Nr. 2921-0050

More information

ThermoSaver TM Hot Gas Defrost System

ThermoSaver TM Hot Gas Defrost System PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin B40-THERM-PDI-14 1069132 ThermoSaver TM Hot Gas Defrost System For use on select

More information

User instructions DHP-AT

User instructions DHP-AT User instructions DHP-AT VUGFC202 If these instructions are not followed during installation and service, Danfoss A/S liability according to the applicable warranty is not binding. Danfoss A/S retains

More information

EHA Hoffmann International GmbH

EHA Hoffmann International GmbH EHA Hoffmann International GmbH User manual EHA-TRANSPRINT HP 2020 Machine-No.: Year: EHA Hoffmann International GmbH Michelsbergstraße 24 D-57080 Siegen/Germany Telephone: +49 271 39 32-0 Telefax: +49

More information

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty OWNER'S GUIDE Gas Continuous Flow Water Heaters Owner's Information Warranty Models 16NG50/16LP50 16NG60/16LP60 20NG50/20LP50 20NG60/20LP60 26NG50/26LP50 26NG60/26LP60 Thermann Owner s Guide Gas Continuous

More information

Sunleaves Air Conditioner

Sunleaves Air Conditioner Sunleaves Air Conditioner Thank you for purchasing this quality Sunleaves Air Conditioner! Please read through this manual completely, and keep it in case you need to reference the information in the future.

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

INSTALLATION GUIDE NZ AU C

INSTALLATION GUIDE NZ AU C DISHWASHER DW60 models INSTALLATION GUIDE NZ AU 591217C 12.17 1 SAFETY AND WARNINGS! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker.

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 BACRF14 Blue Air reserves

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

17 OPERATING AND INSTALLATION MANUAL - EN

17 OPERATING AND INSTALLATION MANUAL - EN 17 OPERATING AND INSTALLATION MANUAL - READ CAREFULLY THE BELOW INSTRUCTIONS PRIOR TO THE INSTALLATION THE HEATER! Dear Customer, The Works Cooperative of Dražice Machine Plant, Ltd., would like to thank

More information

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage. Dehumidifier 2in1: Dehumidifying & air purifying CA-707 Manual Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage. Copyright : Clean Air Optima

More information

Operating Instructions UniTech Perfect

Operating Instructions UniTech Perfect Operating Instructions UniTech Perfect Technische Daten Rated Voltage Power Consumption Max. flow rate Max. head height Cable Protection Dimensions Weight Perfect 5000 49W 5100 l/h 1,85m Perfect 7000 78W

More information

Settings and Maintenance of the CombinAir

Settings and Maintenance of the CombinAir Atmos CombinAir Settings and Maintenance of the CombinAir Issue 13.8.10 Operation and commissioning: The control unit on the front of the CombinAir is used to adjust the settings during commissioning.

More information

REFRIGERATED RECIRCULATORY COOLER

REFRIGERATED RECIRCULATORY COOLER REFRIGERATED RECIRCULATORY COOLER MODEL INCLUDES: TRC-3000 Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline Scientific ABN 80 000 859 129 10-12 Ross Place. Wetherill Park N.S.W. 2164. Australia.

More information

Unvented Electric Water Heater 10/15 litre Undersink

Unvented Electric Water Heater 10/15 litre Undersink Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9

More information

Important Notes: Please read carefully before installing your refrigerator.

Important Notes: Please read carefully before installing your refrigerator. Model: Important Notes: Please read carefully before installing your refrigerator. This Labcold product has been made with great care, tested thoroughly before being sent to you, and is expected to give

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL PORTABLE ICE MAKER Model: IM-124S INSTRUCTION MANUAL It is important that you read these instructions before using your portable ice maker and we strongly recommend that you keep them in a safe place for

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION REV. 8.xx 04.07.2005 Installation and Operation Instructions for Models of AMX / AUX Series Content Page 1 Installation... 3 2 Connections...

More information

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit Installation Manual Add-on Controller Installation Kit NPE-180A/240A This device is designed to work with NPE-180A/240A models ONLY. WARNING All Installations should be done only by a qualified expert

More information

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron. User Manual Warranty Oliso, Inc. warrants that for a period of one year from the date of the original purchase, this product will be free from defects in material and workmanship, when utilized for normal

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

UFM-T100H US ES CA Power Alarm Test TM

UFM-T100H US ES CA Power Alarm Test TM Alarm Power TM UFM-T100H US ES CA A E F I J K G B C D H L M N O P Q R S T U V W X US 1 3 2 Power Alarm 4 6 5 Power Alarm 7 9 8 Po we Ala r rm Power Alarm 10 11 Po we Po we Ala rm r 12 Pow Ala Ala rm r

More information

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11 OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES F88EN-02.indd 1 04.09.2015 8:07:11 2 VKM ЕС CONTENT Introduction Use Structural designation key Delivery set Main

More information

Vacuum Cleaner User's manual

Vacuum Cleaner User's manual User's manual SVC 52BK / SVC 52GR / SVC 52WH Before first use, please read all instructions contained in this user's manual carefully, even if you are already familiar with using similar products. Only

More information

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT 200 300 500 INSTALLATION AND OPERATION MANUAL WARRANTY CARD Contents: 1. Structure and Intended Use... 3 2. Safety devices and conditions for safe

More information

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN TTK 75 E EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport... 05 Operation...

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

GEYSERWISE INSTRUCTION MANUAL

GEYSERWISE INSTRUCTION MANUAL GEYSERWISE INSTRUCTION MANUAL GEYSERWISE MAX DELTA T ALL IN ONE HOT WATER MANAGEMENT Before operating and installation, carefully read all instructions. Do not discard this manual. INDEX 1. Package Contents

More information

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements

More information