Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com
|
|
- Donald Reynolds
- 5 years ago
- Views:
Transcription
1 A Geothermal Energy Generation Facility Embraces Infrared Polymer Window Inspections By Dominique Capili, Spectrum Scientific Corporation (An IRISS Distributor) Overview: A prominent geothermal energy producer in the Philippines has become a leader through the successful development and operation of numerous energy projects. Since 1983, the company has successfully developed, financed, built and operated seven geothermal steam fields for both wet and dry steam and also owns and operates eleven geothermal power plants. Using the company s expertise, they seek continual improvements to ensure the safe and efficient construction and operation of current and future power plants.
2 Temperature plays a key role in the everyday maintenance and condition monitoring processes of a power plant. Temperature is the first parameter that is monitored to measure the health of the equipment. Maintenance professionals have been integrating thermography in their maintenance programs to increase efficiency and determine if the equipment is still within the allowable temperatures set by its OEM during operation. For an effective thermographic survey, one must have a direct line of site exposing the surface to be measured. Previously, for an electrical inspection of a 4160-volt metal clad switchgear, the inspector had to remove eight bolts, carefully lift and removed the heavy steel back cover away from the panel and then later inspect it with an infrared camera. This procedure is time consuming, troublesome and most of all, dangerous due to the increased risk of producing an arc flash. Thermography is used in maintenance programs because of three unique characteristics: 1. It can be performed at a safe distance away from the hazards surrounding the equipment without compromising the safety of the plant personnel 2. Two-dimensional inspections enable the visualization of the changes in heat patterns on the surface of the equipment. This assists in the interpretation of what or where a fault may occur. 3. Real-time visualization of thermal patterns helps analyze the equipment in its fully energized state Infrared polymer windows, when mounted on fully energized equipment, allow infrared energy to pass through making thermography inspections safe and in compliance with NFPA/CSA/OSHA or any other local safety regulations. Inspections are completed without equipment shut-down providing real-time data assessments of a facility s critical assets. Installation Over a period of 3 weeks, twenty-seven (27) IRISS Infrared Windows were recently installed with no lost time or accidents. Due to safety concerns, the previous site survey and visual inspection was limited to external surface temperature measurement and visual inspection of panels with the absence of opening any doors or covers. The preliminary installation design was based on shop drawings that determined the quantity, size and specifications of the infrared windows needed. During the scheduled shutdown, actual visual inspections and de-energized opening of panels was conducted to identify and verify which components would be a main priority for the infrared inspections. Several windows sizes and exact locations were changed once the open panel inspections were performed. In total, twenty-two (22) CAP-C-6 and five (5) CAP-C-4 windows were installed on twelve (12) 4.16kV panels and fifteen (15) 13.8kV panels, generators and transformers.
3 Installation Photos Pre-Installation Step 1: Lay Out Post Installation Step 2: Cutting & Drilling
4 Step 3: Touchup Painting Equipment Testing Step 4: Mounting The last few days were allocated for bench testing, simulation of readings using multiple OEM IR camera types and training of personnel. The simulation of readings using the various camera types and a Black Body temperature source through the IRISS infrared polymer windows measured distance corrected ambient temperature, emissivity usage values and parameter setting on the respective devices. Bench Testing:
5 Black Body Simulation: Where possible, connections were taped with known emissivity insulating tape. In this way, more accurate temperature readings can be taken of the target potential hot spots. Emissivity Tape Mounting: As an opaque polymer optic was used on this project, digital photos were taken and laminated and then placed adjacent to the respective inspection window. Target locations for IR inspection were included on the digital image as well as the proper transmission rate for each camera type that might be used by the inspector. In this way, the future IR inspector will have a better idea of what they are looking at with the IR image and it will ensure consistent and accurate temperature data collection methods.
6 Labelling: Conclusion Since the initial IR Window installation, the program has helped the inspection team decrease the time required to conduct inspections as it does not require a hot work permit and can be done by a single person with no need for special personal protective equipment (PPE). As of publication of this document, they have not found any serious faults but have observed some slight temperature rise on some assets that are being trended and monitored for future change. Plans are being made to expand the use of IR windows on other equipment at this site as well as other power plants owned by the power producer.
Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com
Custom Solutions for High Arc Flash Incident Energy and Interlocked Electrical Enclosures By Mark Bowling, Level II Thermographer, IRISS Inc. & Rick Miner, Level III Thermographer, Thermal Techniques Overview:
More informationWhite Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com
Reducing Arc Flash Risks with Electrical Maintenance By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: Electrical accidents, such as arc flashes, happen daily; however, there
More informationReducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2
Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2 By: Martin Robinson, CEO of IRISS Group and Level III Thermographer Abstract Every year thousands electrical workers are injured
More informationA Powerful Case for Infrared Windows
ROI A Powerful Case for Infrared Windows By Martin Robinson, CMRP Level III Thermographer CEO, IRISS, Inc. Overview: A regional Facility had been tasked by their insurance carrier to perform regular preventive
More informationCAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:
CAP Series Who Says Infrared Windows Have to be Round? The durability and proven transmission stability o our patented reinforced polymer is the cornerstor of the CAP Series. Traditional round infrared
More informationPredictive Maintenance Training
Predictive Maintenance Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq This predictive maintenance
More informationAre Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography?
Are Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography? Gregory R. Stockton, President Stockton Infrared Thermographic Services, Inc. & United Infrared, Inc. 8472 Adams
More informationNFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?
NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In? Adrian Messer, Manager of US Operations UE Systems, Inc. Ph: 864-224-4517 Cell: 914-282-3504 Web: www.uesystems.com
More informationFluke IR Windows Easier NFPA 70E compliance without compromising on product performance.
ndustr Proce Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Electric Why open enclosures and expose yourself to arc flash hazards when you don t have to? Infrared
More informationFluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com
ndustr Proce Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Electric Outdoor/indoor any voltage, arc-tested Indoor medium voltage Indoor low voltage info@ Available
More informationWhite Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com
OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010 By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: The National Fire Protection
More informationinfrared inspections efficient solutions. focused results.
infrared inspections efficient solutions. focused results. efficient solutions. focused results. Infratech is a Canadian company incorporated in 1987 that is focused on providing industry leading products
More informationEnhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08
2 Table of Contents Enhancing Current Maintenance Practices 04 Managing the Risk 06 Constant Monitoring of Electrical Enclosures 08 Delta T Alert A Simple Device with Staggering Results 10 An Easy Way
More informationNFPA 70B and the Importance of Electrical Predictive Maintenance
NFPA 70B and the Importance of Electrical Predictive Maintenance PRESENTED BY Bhanu Srilla Director of Product Marke0ng Grace Engineered Products, Inc. Learning Objectives 1. Review NFPA 70B Maintenance
More informationCommon Misconceptions Relating to Infrared Inspection Ports
Common Misconceptions Relating to Infrared Inspection Ports Martin Robinson, Managing Director Global Maintenance Technologies Chelford Court, Robjohns Road Chelmsford, Essex CM1 3AG United Kingdom Ph:
More informationWhite Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.
NFPA 70E 2018 Edition Changes and Implications for Personnel Performing Condition Based Maintenance By Rudy Wodrich, P.Eng., MBA, CRL, L1 Thermographer, VP Engineering Services, IRISS Inc. Abstract: The
More informationVPFR. cma. Product Brochure. Industrial-Grade Infrared Inspection Viewing Panes
VPFR Industrial-Grade Infrared Inspection Viewing Panes m n issi g u ve been o y See what Product Brochure cma VPFR The adoption of infrared (IR) inspection windows in industrial applications grows exponentially
More informationWhite paper. OSHA and NFPA 70 Safer by Design The History of IRISS. Infrared Windows. Abstract: iriss.com
OSHA and NFPA 70 Safer by Design The History of IRISS By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: As CEO and Founder of IRISS, Inc., I am often asked how and why I
More informationThermography Report. For: (Client) at: (location)
Thermography Report A SAMPLE INFRARED REPORT INFRARED BUILDING EVALUATION For: (Client) at: (location) Thermography date: 01-01-2013 Thermographer: Dave Sawyer, ITC Level III TIR Outdoor temperature: (Temp)
More informationBroadening IR applications through using spectral filters
Broadening IR applications through using spectral filters Inframetrics-Europe, Meche/sesteenweg 277, B-1800 Vilvoorde, Belgium Tel. (32) 2 257 90 30, Fax. (32) 2 257 90 39, e-mail: guy.pas@inframetrics.be
More informationCertification of Thermographers
CFPA-E No 3:2011 F Certification of Thermographers CFPA-E -GUIDELINES FOREWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation
More informationInfrared Business Tips & Insight
Infrared Business Tips & Insight 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only Infrared Business Tips & Insight Presenter:
More informationMonitoring of Electrical Equipment Failure Indicators and Alarming
Past, Present and Future Maintenance Practices: Monitoring of Electrical Equipment Failure Indicators and Alarming Author: Gabe Paoletti, P.E. Eaton Corporation Senior Member, IEEE gabrieljpaoletti@eaton.com
More informationArc Flash Protection Training - NFPA 70e Electrical Safety
Arc Flash Protection Training - NFPA 70e Electrical Safety Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq
More informationINFRARED WINDOW SERIES
XDV SERIES IR & VISUAL INSPECTION WINDOW INFRARED WINDOW SERIES TURTLE TOUGH IR WINDOWS RANGE offers you a more EFFICIENT & SAFE PROCESS to perform visual & INFRARED INSPECTIONS Our products: LARGE-FORMAT
More informationIR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows
IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows Abstract There exists a dangerous misconception regarding the Arc Rating of IR viewing windows or viewing panes.
More informationDelta T Alert: Wireless Temperature Monitoring of Electrical Enclosures
Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures Fred Baier, Level III Certified Infrared Thermographer Delta T Engineering, LLC 136 Main Street Metuchen, NJ 08840 Ph: 877-321-0576
More informationCoal Pile Fire Monitoring System
Coal Pile Fire Monitoring System Land Instruments International Over 60 years experience Specialists in Infrared Temperature Measurement Combustion Efficiency & Environmental Emissions Monitoring Joined
More informationInfrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows
Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows Tim Rohrer, VP of Sales & Marketing Martin Robinson, President and IRISS, Inc. 4914 Lena Road, Suite 105 Bradenton, FL
More informationProperty risk solutions
Property risk solutions Inside this issue Welcome to this edition of the Property risk solutions newsletter. This quarterly publication focuses on fixed fire protection and human element safety solutions
More informationElectrical Safety Compliance: NFPA 70E
Electrical Safety Compliance: NFPA 70E From Graybar and Schneider Electric Risks associated with shock and electrocution from inadvertent contact with energized parts have long been recognized as a threat
More informationNFEC FIRE SAFETY SEMINAR Krish Mysore
NFEC FIRE SAFETY SEMINAR 2018 Krish Mysore krish.mysore@schneider-electric.com Agenda 1 Electrical Fire Stats 2 Types of Electrical Fires 3 Electrical Risk Management 4 Electrical Health Check Assessment
More informationTHERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR
THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR Christian PETIT Anticipation manager Schneider Electric - Network protection and control unit -Marketing
More informationWhite Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com
Maintenance Inspection Windows on Transformers By Rudy Wodrich, P.Eng., MBA, CRL, VP Engineering Services, IRISS Inc. Abstract: Everyone knows that Thomas Alva Edison invented the lightbulb but who invented
More informationA WORLD WITHOUT DOWNTIME
ELECTRICAL INFRARED INSPECTION High temperatures may indicate excessive electrical resistance, failing components, ground faults, short circuits or other common problems in equipment that can lead to expensive
More information17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee
17 TH APRIL Switch Board Monitoring Protecting Switchboard Courtesy of ABB. www.fengshengelectric.com.sg Paul Lee Agenda 1. Introduction 2. IEC 61439 3. Why Switchboard Monitoring 4. Switchboard Monitoring
More informationSurface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes
Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes Summary Safety is a big concern when it comes to managing power distribution systems. High
More informationNECA S System Approach to Electrical Safety for NFPA 70E
NECA S System Approach to Electrical Safety for NFPA 70E NECA s Systems Approach to NFPA 70E Easy to understand NFPA 70E employer requirements, Provides Supervisors with key on the job information, De-energize
More informationImplementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation
Implementing an Energized Electrical Work Program SESHA Hill Country Chapter May 22, 2009 Brett Jay Davis, PE Zephyr Environmental Corporation bdavis@zephyrenv.com, 512 879-6628 Presentation Outline 1.
More informationBasic Vehicle Fire Protection Manual
Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual TABLE OF CONTENTS Introduction... 3 System Operation...... 5 Component Overview.... 7 Operator Controls Control Panel.........
More informationCONTINUOUS MONITORING IS ON THE RISE:
CONTINUOUS MONITORING IS ON THE RISE: CAN YOU ADAPT? BY WILLIAM HIGINBOTHAM, EA Technology LLC Electrical testing companies have traditionally built their businesses by periodically running tests on electrical
More informationPROTECTING AGAINST ARC FLASH HAZARDS
PROTECTING AGAINST ARC FLASH HAZARDS Presented by: Andrew J. Fitzpatrick, P.E. Electricity Simply stated electricity is the flow of electrons Electricity is governed by laws: Ohms Law : V=IR Kirchoff s
More informationSAFETY MANUAL. Multispectrum IR Flame Detector X3301
SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper
More informationMeasuring Couch Motion Accuracy with X-ray Beam Fluence
Measuring Couch Motion Accuracy with X-ray Beam Fluence Rudi Labarbe, M.S. and Brett Nelson, M.S. IBA Particle Therapy, Belgium and Logos Systems, Scotts Valley, CA Introduction The accuracy of radiosurgery
More informationTIAMA recognizing critical defects immediately at the hot-end thanks to the Tiama HOT eye
TIAMA recognizing critical defects immediately at the hot-end thanks to the Tiama HOT eye Tiama HOT eye Tiama is continuing to expand and develop its hot-end sensor equipment to ensure the best return-on-investments
More informationUtilizing Finite Element Analysis (FEA) for Flexible Heater Designs
Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Ryan Mohs, Process Engineer, All Flex. Flexible heaters are commonly utilized in many different heating applications. Generally, these
More informationUSING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES. James L. Park Energy Conservation Specialist I-Star Energy Solutions
USING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES James L. Park Energy Conservation Specialist I-Star Energy Solutions Facilities are inundated with people selling devices and technology
More informationOctober Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance
Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance Christopher Hallum, CMRP Regional Manager UK & Ireland UE Systems UK & Ireland ULTRASOUND TECHNOLOGY HOW DOES IT WORK?
More informationEmerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT
October 25, 2016 Media contact: Grace Capwell O 1 (512) 834-7214 M 1 (512) 840-8209 Grace.Capwell@Emerson.com Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial
More informationHow to spot and address potential process problems using thermal imaging
How to spot and address potential process problems using thermal imaging Application Note By John Pratten, Fluke Thermography In the past several years, thermal cameras have transformed from a specialist-only
More informationCOMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER
COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise
More informationNECA S System Approach to Electrical Safety for NFPA 70E
NECA S System Approach to Electrical Safety for NFPA 70E NECA s Systems Approach to NFPA 70E Easy to understand NFPA 70E employer requirements, Provides Supervisors with key on the job information, De
More informationUsing Infrared for Residential Energy Surveys
Using Infrared for Residential Energy Surveys Dave McCullen Sumter Electric Cooperative Inc. ABSTRACT In the electric industry today, advising consumers on energy conservation has replaced selling energy
More informationDevelopment of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1
Development of standards for MV Switchgear for Arc Flash protection May 20, 2013 Slide 1 Development of standards for MV Switchgear for Arc Flash protection Bryan Johnson ABB South Africa Shaping the world
More informationGuidance on Video Smoke Detection Technology (VSD)
Guidance Note Guidance on Video Smoke Detection Technology (VSD) Guidance on Video Smoke Detection Technology (VSD) SCOPE... 3 INTRODUCTION... 4 WHAT IS VSD?... 5 STANDARDS... 7 GENERAL GUIDANCE ON THE
More informationDomestic Infrared Thermography Class 1 Operators Qualification Specification
Level 3 Certificate in Domestic Infrared Thermography Class 1 Operators Qualification Specification Qualification Recognition Number: 601/2687/5 ABBE Qualification Code: CertDITL314 December 2017 Why this
More informationBlack Body Calibration Source User Manual
Black Body Calibration Source Surface Plate Type with External Controller Model CBB18GC- 2 WD1069 Rev B 10/23/17 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853
More informationSAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors
SAFETY MANUAL X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY-CERTIFIED Flame DETECTORs This manual addresses the specific requirements and recommendations applicable to the proper
More informationFS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com
Model Infrared Food Thermometer FS-200 Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Display Description... 5 Operating
More informationPulse Firing Doubles Capacity and Cuts Fuel Costs
Honeywell Combustion Safety 11699 Brookpark Road Cleveland, Ohio 44130 www.combustionsafety.com Pulse Firing Doubles Capacity and Cuts Fuel Costs Why Pulse Fire? Many industrial manufacturing leaders are
More informationCompliance without compromise Safety without sacrifice
Compliance without compromise Safety without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise
More informationSOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY
SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY 6/12/2010 Recent IR Thermography Developments Can Help Agenda: Infrared Cameras for Solar Cell Inspection Survey of current solar cell test methods New
More informationTollgrade Lighthouse Sensor Pilot at CenterPoint Energy. Presented at SWEDE 2011
Tollgrade Lighthouse Sensor Pilot at CenterPoint Energy Presented at SWEDE 2011 Outline History Objectives of Pilot Current Pilot Status Summary 2 History CNP has tried sensors/detectors before Too many
More informationWHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE
WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE AGENDA SCRWA 14 SEPTEMBER 2016 Definition Why EDPM is essential to productivity Fiscal sustainability Why EDPM is essential
More informationPerformance Based Gas Detection System Design For
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with performance based gas
More informationWagner Meters has been an industry leader for over 40 years, creating innovative top-of-theline moisture measurement equipment.
Home Inspection Tools: Why a Moisture Meter Is Essential Not all home inspectors have identical industry knowledge. Credentials and licensing may vary depending on which state you live in, but the recommended
More informationMethane to Markets Oil and Natural Gas Technology Transfer Workshop
Methane to Markets Oil and Natural Gas Technology Transfer Workshop Detection and Measurement of Fugitive Emissions Using Airborne Differential Absorption Lidar (DIAL) Daniel Brake ANGEL Service ITT Space
More informationSEL Arc-Flash Solutions
SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment
More informationAPPLICATION NOTE INFRARED SCANNING FOR ENERGY EFFICIENCY
APPLICATION NOTE INFRARED SCANNING FOR ENERGY EFFICIENCY ASSESSMENT Paul De Potter May 2017 ECI Publication No Cu0192 Available from www.leonardo-energy.org Document Issue Control Sheet Document Title:
More informationInfrared Inspection Reference Letters Commercial & Residential
Infrared Inspection Reference Letters Commercial & Residential Cascade Thermal Imaging, Inc. P.O. Box 2131 Redmond, WA 98073-2131 425-861-3887 www.cascadethermal.com ~ Infrared Inspection The Non-Invasive
More informationMulti-Technology Fault Identification
Multi-Technology Fault Identification By: Reggie Fett, MCA/IR Analyst Industry: Food and Beverage Component: Motor Technology: On-line MCA (Initially) Part: Electrical Connections Time Context Tuesday,
More informationSEL Arc-Flash Solutions
SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment. Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment
More informationContinuous, real-time detection, alarming and analysis of partial discharge events
DMS PDMG-R Partial discharge monitor for EHV GIS Continuous, real-time detection, alarming and analysis of partial discharge events Automatic PD fault classification Robust design allows for reliable operation
More informationEC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM
EC100 PROCESS IMAGING SYSTEM ENGLISH EC100 Thermal Imaging System for Quality Control in Extrusion Processes The EC100 provides real time temperature analysis for extrusion coating processes. (Photo: Courtesy
More informationPD alarm system brings peace of mind in Malta
(173 words) CASE STUDY - Enemalta How effective is continuous monitoring of Partial Discharge (PD) activity in MV substations? This case study is based on a paper presented jointly by state utility Enemalta
More informationPIPELINE LEAKAGE DETECTION
PIPELINE LEAKAGE DETECTION Fiber-Optic Leakage Detection System AP Sensing: Your trusted partner for fire detection AP Sensing is your global DTS solution provider for your pipeline monitoring needs. We
More informationCCTV, HOW DOES IT WORK?
August 25, 2005 CCTV FLAME DETECTION Video flame detection is an attractive concept. We ve all heard the adage, seeing is believing. In short, we trust our eyes to deliver accurate information. New designs
More informationTi Thermal Imaging LTD
Ti Thermal Imaging LTD Unit 8, Weybridge Business entre, 66 York Road, Weybridge, Surrey, KT13 9DY Tel: 0845 458 6315 Fax: 0871 9004978 E-mail: info@thermalimaging.co.uk Web: www.thermalimaging.co.uk THERMOGRAPHI
More informationAn ASSA ABLOY Group brand. ABLOY Safety and Security Systems for Petroleum
An ASSA ABLOY Group brand ABLOY Safety and Security Systems for Petroleum safety and Security in any environment The world is challenged by mounting security threats in every conceivable sector. The need
More informationManual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80
Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80 isplay Anzeige Affichage Pantalla isplay C/ F Switch C/ F-Schalter Commutateur C/ F Interruptor de C/ F Chave C/ F Laser Laser Laser Láser
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Supplement Manual Title: 4180, 4181 Technical Guide Supplement Issue: 3 Part Number: Web-Only Issue Date: 4/18 Print Date: March 2013 Page Count: 4 Revision/Date: This supplement contains information
More informationPGR-8800 TECHNICAL FAQ
PGR-8800 SOLAR ARC-FLASH PRODUCTS RELAY CATALOG TECHNICAL FAQ What are the typical applications / system voltages? The PGR-8800 can be used on electrical systems operating at any voltage (AC or DC) since
More informationEffective Alarm Management for Dynamic and Vessel Control Systems
DYNAMIC POSITIONING CONFERENCE October 12-13, 2010 OPERATIONS SESSION Effective Alarm Management for Dynamic and Vessel Control Systems By Steve Savoy Ensco Offshore Company 1. Introduction Marine control
More informationWhy are infrared cameras indispensable for building inspections?
Why are infrared cameras indispensable for building inspections? What is infrared thermography? Thermography, also called thermal imaging, is the production of non-contact infrared or heat pictures from
More informationRESNET Infrared Inspection Standard and Certification
RESNET Infrared Inspection Standard and Certification Rogge Miller Guaranteed Watt Savers John Snell Snell Infrared RESNET 2009 Slide #1 Infrared Standard & certification Why create a new standard? I don
More informationClassifying Forced Outages Transmission Maintenance Procedure No. 5
Classifying Forced s Transmission Maintenance Procedure No. 5 Version 4 Effective Date 10/17/2017 Approved by: Transmission Maintenance Coordination Committee 10/17/2017 CAISO Public Classifying Forced
More informationMining Automation: Sensing Technologies
Mining Automation: Sensing Technologies Jonathon Ralston CSIRO Exploration & Mining 2008 Narrow Vein Mining Conference PRESENTATION OVERVIEW Why Mining Automation? Smart Sensors for Automation Case Study:
More informationDeveloping ambient lighting products for the next generation of vehicles
Developing ambient lighting products for the next generation of vehicles Ralf Meyer-Wendt Global R&D Technology Manager May 17, 2012 Agenda Company overview Interior lighting research and trends Lighting
More informationMaintenance Strategy for High Pressure Piping Systems. by Ewert Snyman
Maintenance Strategy for High Pressure Piping Systems by Ewert Snyman Introduction Basic Design Principles Piping Inspections Maintenance Strategy Maintenance Methods Conclusion and Questions Content
More informationHigh Temperature InfraRed Thermometer with Laser Pointer
User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42545A Introduction Congratulations on your purchase of the Model 42545A IR Thermometer. The 42545A is capable of non-contact
More informationI/R Thermometer Gun 12:1
I/R Thermometer Gun 12:1 800103 INSTRUCTION MANUAL SPER SCIENTIFIC Contents Page 1. Introduction... 2 2. Safety Information... 3 3. Display And Button Locations... 4-5 4. Distance to Spot... 5 5. Measuring
More informationProducts Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2
Products Solutions Services Food & Beverage industry Slide 2 Why is energy management an important topic? Energy prices influence production costs, End-consumer looks for sustainable products, companies
More informationOil Burner Controls LMO24... LMO44...
7 130 Oil Burner Controls LMO14... LMO24... LMO44... Microcontroller-based oil burner controls for the startup, supervision and control of forced draft oil burners in intermittent operation. Standard versions
More informationArc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the
GROUP Arc Flash Analysis Arc Flash Hazard Analysis : Arc flash hazard analysis is required to determine the risk to personnel, warn them of the hazards, and to instruct working personals as to what kind
More informationPIDS Sensor Installation & Maintenance. 15/03/13/Rev1/PIDS Sensor Installation & Maintenance 1
PIDS Sensor Installation & Maintenance 15/03/13/Rev1/PIDS Sensor Installation & Maintenance 1 The information contained herein contains proprietary information of ST Electronics (Satcom& Sensor Systems)
More informationChanges to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC
Changes to NFPA 70E - The Role of PdM &Safe PdM Work Practices Tim Rohrer Exiscan LLC Tim@Exiscan.com 585-705-7775 Joe Gierlach ABM Joseph.Gierlach@ABM.com 412-394-4678 Preview Electrical Safety Risk Management
More information.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.
Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code
More informationStandard for Infrared Inspection of Building Envelopes
Standard for Infrared Inspection of Building Envelopes 2016 Edition Infraspection Institute 425 Ellis Street Burlington, NJ 08016 www.infraspection.com Standard for Infrared Inspection of Building Envelopes
More informationNORTH TECHNICAL UNIVERSITY ENGINEERING SCHOOL OF APPLIED SCIENCE. Maintenance Electric Engineering TECHNICAL REPORT
NORTH TECHNICAL UNIVERSITY ENGINEERING SCHOOL OF APPLIED SCIENCE Maintenance Electric Engineering TECHNICAL REPORT THERMOGRAPHIC ANALISYS AS APPLIED TECHNIQUE OF PREDICTIVE MAINTENANCE IN THE ELECTRICAL
More informationELECTRICAL/MECHANICAL INFRARED INSPECTION REPORT. The Corporate Facility 2001 Freedom Way United City, USA
ELECTRICAL/MECHANICAL INFRARED INSPECTION REPORT for The Corporate Facility 2001 Freedom Way United City, USA January 01, 2012 Job Number: 1111-12 TABLE OF CONTENTS I - Introduction to the Report Explains
More information