Maintenance Strategy for High Pressure Piping Systems. by Ewert Snyman

Size: px
Start display at page:

Download "Maintenance Strategy for High Pressure Piping Systems. by Ewert Snyman"

Transcription

1 Maintenance Strategy for High Pressure Piping Systems by Ewert Snyman

2

3 Introduction Basic Design Principles Piping Inspections Maintenance Strategy Maintenance Methods Conclusion and Questions Content

4 Steinmüller Engineering Services specialise in High Energy Piping Systems High Temperatures normally between 500 C and 560 C but systems as high as 800 C has been analysed High Pressures normally between 5MPa and 30MPa Introduction

5 Introduction A specialized maintenance strategy is required on these piping systems due to the following: Limited system life Severe impact in case of failure Specialised testing requirements and methods Extraordinary long lead times on replacement material Specialised replacement or refurbishment methods

6 Basic Design Principles To understand the maintenance strategy the basic design principles must be understood: Material selection Piping layout Support system The implementation of these principles must first of all meet the design code requirements, but also have a direct impact on the long term health of the plant.

7 Basic Design Principles Before any maintenance activity can start, detailed information on the piping system must be available: The relevant piping design code The design conditions, i.e. design pressure and design temperature The operating conditions, i.e. originally anticipated operating pressure and operating temperature The piping material and the code to which it was ordered The piping dimensions, i.e. the outer diameter or inner diameter and wall thickness the piping was ordered to The piping layout, i.e. an isometric drawing showing the basic layout of the piping The cold pull dimensions A schedule indicating the support types, loads and travels, as well as clear indications on the isometric drawings where the supports are The isometric drawing must also indicate the locations of the piping welds The insulation specification, i.e. the thickness, density and conductive properties of the insulation

8 Piping Condition Evaluation To determine the maintenance strategy and maintenance activities the following information must be available: Material Condition Life Usage Factor As-built Flexibility Model Results Support System Condition Sloping and Drainage Thermal Insulation Condition

9 Piping Inspections and Testing The purpose of the inspection and testing of a piping system is two fold: Firstly to verify the integrity of the piping system, which is aimed at its short term operation and mostly consists of non destructive testing NDT to determine integrity of welds Pressure testing Replica taking to determine creep degradation Secondly to determine the condition of the system, which is aimed at its long term health Record operational data Perform dimensional tests Perform elevation surveys Survey support system Test and calibrate supports Perform infrared scanning Replica taking to determine creep degradation

10 Maintenance Strategy The maintenance strategy of the piping is thus forced into pure condition based maintenance.

11 Maintenance Activities Due to the inherent complexity in the configuration of the piping system, specialised methods are required for the replacement of components. With the replacement of piping components the originally installed cold pull must be retained: Re-instate the original cold pull as per the original installation method Restrain the piping movement local to the section to be replaced

12 Maintenance Activities Restraining the piping only maintains the cold pull for the sections not influenced by the refurbishment work - the installed cold pull influence the shape of the entire piping system, and thus the larger the portion being replaced the more cold pull will be lost. The restraining of the piping is achieved by the installation of the blocking frames. The loading on the blocking frames and the amount of cold pull that will be lost must be calculated.

13 Maintenance Activities Without restraining the piping or due to partial loss of cold pull, the piping must be balanced (balanced erection) during installation such that the piping is in it s neutral position when the piping is aligned for welding. The alignment for the final weld must be such that the piping ends are the required cold pull distances apart. This requires detailed planning upfront to take place since the last and second last weld locations must be specifically selected to achieve the required cold pull successfully.

14 Conclusion and Questions Thus to ensure the short and long term health of a high pressure and high temperature piping system, a specialized maintenance strategy is required. Questions?

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com A Geothermal Energy Generation Facility Embraces Infrared Polymer Window Inspections By Dominique Capili, Spectrum Scientific Corporation (An IRISS Distributor) Overview: A prominent geothermal energy

More information

INCREASED RELIABILITY / REDUCED RISK BY APPLYING INTELLIGENT PIGGING TECHNOLOGY TO INSPECT COILS IN PROCESS HEATERS

INCREASED RELIABILITY / REDUCED RISK BY APPLYING INTELLIGENT PIGGING TECHNOLOGY TO INSPECT COILS IN PROCESS HEATERS 4th Middle East NDT Conference and Exhibition, Kingdom of Bahrain, Dec 2007 For all papers of this publication click: www.ndt.net/search/docs.php3?mainsource=57 INCREASED RELIABILITY / REDUCED RISK BY

More information

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL RENEWABLE ENERGY TECHNOLOGIES IN ASIA: A Regional Research and Dissemination Programme Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL Energy Field of Study School of Environment, Resources

More information

POWERENERGY

POWERENERGY Proceedings of the ASME 2015 Power & Energy Conversion Conference POWER2015 June 28-July 2, 2015, San Diego, CA, USA POWERENERGY2015-49418 IMPROVEMENTS IN THE PERFORMANCE OF A SUBCOOLING ZONE IN A FEEDWATER

More information

SUMMARY. On completion of all of the five tests, general body concentrations of ozone gas within the room monitored were less than 0.01 ppm.

SUMMARY. On completion of all of the five tests, general body concentrations of ozone gas within the room monitored were less than 0.01 ppm. SUMMARY The results indicated that the maximum general body concentration of ozone gas during trial operations of the Ozone Clean Limited OC1500 Ozone Generator-Destructor Machine was 2.65 ppm. On completion

More information

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax: Code of Practice // For the installation, inspection and testing of electrical installations tel/fax: 0870 241 7687 email: mpba@mpba.biz Introduction // This code of practice provides guidance for manufacturers,

More information

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland Available on CMS information server CMS CR -2016/298 The Compact Muon Solenoid Experiment Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland 28 October 2016 (v2, 25 November 2016)

More information

October 7, 2016 Meeting Landfill Liner Regulations with Conductive Backed Geomembranes by Doyin Adesokan B.Eng Msc. Technical Manager - Solmax

October 7, 2016 Meeting Landfill Liner Regulations with Conductive Backed Geomembranes by Doyin Adesokan B.Eng Msc. Technical Manager - Solmax Covering the world. Protecting the earth. October 7, 2016 Meeting Landfill Liner Regulations with Conductive Backed Geomembranes by Doyin Adesokan B.Eng Msc. Technical Manager - Solmax Outline Quote What

More information

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT # INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #236477-001 Specifications... 1 Overview Silent Dial Thermostat Art. 236477-001... 1 Mounting Location... 3 DIP Switch Configuration... 3 Calibration... 5 Setting

More information

Fundamental of Heating

Fundamental of Heating Address:4F-3, No.46,Sec.2, Zhong Shan N. Rd., 10448 Taipei,Taiwan 台北市中山北路二段 46 號 4F-3 Tel:886-2-25113207 Fax:886-2-25113201 Fundamental of Heating (1)Understanding of Heating Element Heating element is

More information

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE Authors: Stefan Glaser Senior Manager Customer Engineering VWA Waldemar Stabroth Director Technical Marketing Contact:

More information

Ognjen Čaldarović, PhD, professor of sociology, Zagreb University Urban Renewal and Transitional Society

Ognjen Čaldarović, PhD, professor of sociology, Zagreb University Urban Renewal and Transitional Society Ognjen Čaldarović, PhD, professor of sociology, Zagreb University ognjen.caldarovic@ffzg.hr Urban Renewal and Transitional Society 1 content 1. Introduction 2. The Most important processes in urban renewal

More information

The development of seat fire testing for EN Richard Nowell

The development of seat fire testing for EN Richard Nowell The development of seat fire 2017 Introduction Introduction This presentation will examine the development of a new standard for complete seat fire testing that will plug into EN 45545-2 to replace Annexes

More information

Cotswolds AONB Landscape Strategy and Guidelines. June 2016

Cotswolds AONB Landscape Strategy and Guidelines. June 2016 Cotswolds AONB Landscape Strategy and Guidelines June 2016 Cotswolds AONB Landscape Strategy and Guidelines Introduction The evolution of the landscape of the Cotswolds AONB is a result of the interaction

More information

Lightweight aggregates in Civil Engineering applications. Arnstein Watn Senior Scientist, SINTEF

Lightweight aggregates in Civil Engineering applications. Arnstein Watn Senior Scientist, SINTEF Lightweight aggregates in Civil Engineering applications Arnstein Watn Senior Scientist, SINTEF SINTEF Independent Multiscience Research Institute About 1800 employees Closely linked to the Universities

More information

Construction of BIOECODS for a Government Complex: A Case Study

Construction of BIOECODS for a Government Complex: A Case Study Construction of BIOECODS for a Government Complex: A Case Study MOHD FAZLY YUSOF, Sceince Officer, River Eingineering and Urban Drainage Centre (REDAC), Universiti Sains Malaysia, Engineering Campus, Seri

More information

Laser Registration Requirements: EH&S must be notified after the purchase any class 3B or 4 lasers through the online Laser Registration Form.

Laser Registration Requirements: EH&S must be notified after the purchase any class 3B or 4 lasers through the online Laser Registration Form. Permit Holder: Laser Class: Class 3B Class 4 Manufacturer Model LASER SAFETY CONTACT FOR YOUR LAB Name Phone Email 1. LASER SAFETY GENERAL CAMPUS POLICIES Responsibilities of the laser operator(s): Operator

More information

Technical Guidance CE Marking of Metal Chimneys and Flues

Technical Guidance CE Marking of Metal Chimneys and Flues CE Marking of Metal Chimneys and Flues Steel Chimney Programme Schiedel is the leading producer of ceramic chimney systems in Europe, and are now regarded as the market leaders in prefabricated stainless

More information

FLEXIBLE CORRUGATED TUBE

FLEXIBLE CORRUGATED TUBE Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated

More information

PIR Occupancy & Motion Sensor

PIR Occupancy & Motion Sensor PIR Occupancy & Motion Sensor MOS-17C energy conservation - home and office Overview The MOS-17C is a wireless, energy harvesting, ceiling mount, Passive InfraRed (PIR) occupancy sensor. Used for indoor

More information

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

A CASE STUDY ON BOILER TUBE FAILURE AT JPL A CASE STUDY ON BOILER TUBE FAILURE AT JPL Introduction: JPL has two no of super critical Boilers (Make: Harbin Boiler Company Limited). This boiler adopts low NOx burners with offset tangential combustion,

More information

The Role of Market Surveillance

The Role of Market Surveillance Certification and Marking for Europe The Role of Market Surveillance Jan Deconinck, M.Sc. PROSAFE Chairman 1. Marks 1. Marks 1. Marks - It is prohibited to affix other markings or marks which might be

More information

9 January 2012 Satmohini Ray Senior Research Fellow

9 January 2012 Satmohini Ray Senior Research Fellow SUSTAINABLE URBAN FORM FOR INDIAN CITIES 9 January 2012 Satmohini Ray Senior Research Fellow RESEARCH STUDY Sustainable City Form in India Aim : The study aims at achieving sustainable development in rapidly

More information

Activity Residential Site Planning

Activity Residential Site Planning Activity 2.3.7 Residential Site Planning Introduction When a building is designed apart from a specific site, an opportunity is lost to match the design to the strengths and weaknesses of the site. To

More information

Marcus Schütte (Product Management) Sebastian Prühl (R&D) Competitive Analysis Sterisart Universal Pump Symbio

Marcus Schütte (Product Management) Sebastian Prühl (R&D) Competitive Analysis Sterisart Universal Pump Symbio Marcus Schütte (Product Management) Sebastian Prühl (R&D) Competitive Analysis Sterisart Universal Pump Symbio 20.05.2016 09.10.2014 Short Overview (1) Feature Sterisart Universal Pump Symbio Merck Millipore

More information

INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS

INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS Prepared by TenCate Geosynthetics North America 365 South Holland Drive Pendergrass, GA 30567 Tel: (706) 693-2226 Fax:

More information

Instructions for use HYDROMETER Hydrometer GM-200 #071054

Instructions for use HYDROMETER Hydrometer GM-200 #071054 Instructions for use HYDROMETER Hydrometer GM-200 #071054 1.Introduction The hydrometer is used to measure the moisture content of concrete, plaster, cement and EPS. It is also possible to analyse of the

More information

Nondestructive Testing of Geomembranes

Nondestructive Testing of Geomembranes From NDT Technician, Vol. 11, No. 2, pp: 1 5. Copyright 2012 The American Society for Nondestructive Testing, Inc. The American Society for Nondestructive Testing www.asnt.org FOCUS Nondestructive Testing

More information

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low voltage power panelboards 1.02 RELATED SECTIONS 1.03 REFERENCES

More information

Wireless Alarm System. User Manual

Wireless Alarm System. User Manual Wireless Alarm System User Manual 1. Configuration List Wireless Alarm Receiver Solar& Wireless Photoelectric Beam Sensor English Manual 1 piece (includes 1 set installation accessories) 1 pairs (includes

More information

Development Brief Ursuline Convent, Blackrock, Cork

Development Brief Ursuline Convent, Blackrock, Cork Development Brief Ursuline Convent, Blackrock, Cork Comhairle Cathrach Chorcaí Cork City Council 2002 URSULINE CONVENT DEVELOPMENT BRIEF 1 INTRODUCTION AND MAIN OBJECTIVES... 3 1.1 The convent estate is

More information

6 th Pipeline Technology Conference 2011

6 th Pipeline Technology Conference 2011 6 th Pipeline Technology Conference 2011 Pipeline Leak Detection and Theft Detection Using Rarefaction Waves Authors: Dr Alex Souza de Joode, VP International Operations; ATMOS International, UK. Andrew

More information

Create Streets We can help you make better places

Create Streets We can help you make better places Create Streets We can help you make better places contact@createstreets.com www.createstreets.com Green wedges - are there alternatives to greenbelts? Mingfei Ma asks if there is a half-way house between

More information

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES Generalities HPLC - PELTIER COLUMN-THERMOSTATS GENERALITIES This manual has been updated to the actual standard. It now covers all the features of the actual Jetstream series models. All rights concerning

More information

Local pilot fact sheet: Via Rizzoli

Local pilot fact sheet: Via Rizzoli Local pilot fact sheet: Via Rizzoli Project partner organisation name: Comune di Milano Name of contact person: Marco Parolin E-Mail of contact person: marco.parolin@comune.milano.it, marco.parolin@tiscali.it

More information

BEVERIDGE ASSOCIATES PARTNERSHIP LIMITED CAPABILITY STATEMENT CATERING AND RETAIL

BEVERIDGE ASSOCIATES PARTNERSHIP LIMITED CAPABILITY STATEMENT CATERING AND RETAIL BEVERIDGE ASSOCIATES PARTNERSHIP LIMITED CAPABILITY STATEMENT CATERING AND RETAIL 1.0 PRACTICE DETAILS 1.01 Name: Beveridge Associates Partnership Limited 1.02 Address: Regency House Station Road Harold

More information

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( ) SERVICE MANUAL Ecoboiler Model range: T20 (1000662) T30 (1000663) Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland

More information

1 2 3 Licence No:

1 2 3 Licence No: TRICS 2007(a) 06/05/07 Page 1 of 6 List of TRICS Research Publications TRICS Report 89/1 Traffic Generation Study of Offices & High Tech Sites London Borough of Hillingdon The report contains detailed

More information

Optical Techniques for Industrial Inspection

Optical Techniques for Industrial Inspection Optical Techniques for Industrial Inspection P. Cielo National Research Council of Canada Industrial Materials Research Institute Boucherville, Quebec, Canada ACADEMIC PRESS, INC. Harcourt Brace Jovanovich,

More information

Local Growth Planning in North Central Green Line Communities

Local Growth Planning in North Central Green Line Communities 2018 April 30 Page 1 of 6 EXECUTIVE SUMMARY This report outlines a high-level scope for local growth planning for north central Green Line communities. The catalyst for this review is the significant investments

More information

TECHNICAL. Design Guide. Retaining walls made easy with this beautiful solution EARTH RETAINING WALLS

TECHNICAL. Design Guide. Retaining walls made easy with this beautiful solution EARTH RETAINING WALLS TECHNICAL Design Guide EARTH RETAINING WALLS Retaining walls made easy with this beautiful solution qro.com.au sales@qsolutionsco.com.au (07) 3881 0208 TDG-ERW-01 Sept 2017 1 RETAINING WALL SELECTION PROCEDURE

More information

COMMISSIONING AND START-UP TESTS OF ALPHA-CONTAMINATED SOLID WASTE SORTING, CEMENTING, AND INTERIM STORAGE FACILITIES AT BELGOPROCESS (BELGIUM)

COMMISSIONING AND START-UP TESTS OF ALPHA-CONTAMINATED SOLID WASTE SORTING, CEMENTING, AND INTERIM STORAGE FACILITIES AT BELGOPROCESS (BELGIUM) COMMISSIONING AND START-UP TESTS OF ALPHA-CONTAMINATED SOLID WASTE SORTING, CEMENTING, AND INTERIM STORAGE FACILITIES AT BELGOPROCESS (BELGIUM) R.C. GLIBERT G. NUYT G. LAMOTTE BELGONUCLEAIRE, 4 avenue

More information

Threats to the environment from high-efficiency condensing devices

Threats to the environment from high-efficiency condensing devices Threats to the environment from high-efficiency condensing devices Authors: Sridhar Deivasigamani, Nithyanandhi Duraisamy www.intellihot.com 2900 W. Main Street, Galesburg IL 61401 309.473.8040 main 309.296.8984

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

A new fully digital system for RT inspection of metal tube to tube sheet joints of heat exchangers

A new fully digital system for RT inspection of metal tube to tube sheet joints of heat exchangers 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China A new fully digital system for RT inspection of metal tube to tube sheet joints of heat exchangers Uwe ZSCHERPEL 1, Oleksandr

More information

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com Reducing Arc Flash Risks with Electrical Maintenance By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: Electrical accidents, such as arc flashes, happen daily; however, there

More information

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to

More information

Progress in modern catering also owes a great deal to the Zanussi Professional System. Professionals in this sector identify the system as the

Progress in modern catering also owes a great deal to the Zanussi Professional System. Professionals in this sector identify the system as the static preparation The System Progress in modern catering also owes a great deal to the Zanussi Professional System. Professionals in this sector identify the system as the driving force behind development

More information

South Seas Inspection (S) Pte Ltd

South Seas Inspection (S) Pte Ltd PRESENTATION October 2009 SSI, your essential business partner for comprehensive & professional Derrick Building, Inspection, Maintenance, Repair & Operational Services to the Oil & Gas, Marine & General

More information

Applicant Name Phone / Fax / Address City State Zip Code . Property Owner Phone / Fax / Address City State Zip Code

Applicant Name Phone / Fax / Address City State Zip Code  . Property Owner Phone / Fax / Address City State Zip Code Master Development Plan Application Community Development Department City of Redmond 411 SW 9 th Street Redmond, Oregon 97756 541-923-7721 541-548-0706 FAX Master Development Plan Fee $38,862.52 File Number

More information

Monitoring of Penetration System Performance due to ISO by using Test Panels due to ISO

Monitoring of Penetration System Performance due to ISO by using Test Panels due to ISO 19 th World Conference on Non-Destructive Testing 2016 Monitoring of Penetration System Performance due to ISO 3452-1 by using Test Panels due to ISO 3452-3 Andreas KINZEL 1, Wolfgang KÖNIG 1, Heide KÜHN

More information

Vision Based Wheel Condition Monitoring

Vision Based Wheel Condition Monitoring Vision Based Wheel Condition Monitoring Kambiz Nayebi Beena Vision Systems, Inc. 1 Beena Vision Systems Inc. YOUR LOGO Condition Based Maintenance Benefits for the Industry High Availability of Rolling

More information

the perfect space guide to workspace fitouts and refurbishments

the perfect space guide to workspace fitouts and refurbishments the perfect space guide to workspace fitouts and refurbishments Outline Design is a leading commercial interior design firm, specialising in designs and fitouts for workspaces within the corporate, hospitality,

More information

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS HHS-WWH PRODUCT SPECIfICATIONS Power density Standard wattages up to 4650 W/m² (3.0 W/in²) Voltage range (nominal) 120 to 600 VAC

More information

State-of-the-art Developments to Save Energy in Coating Drying

State-of-the-art Developments to Save Energy in Coating Drying State-of-the-art Developments to Save Energy in Coating Drying Executive Summary Coating drying is expensive. A great deal of energy is needed to effectively evaporate sufficient water to dry the coating.

More information

SECTION ONE North East Industrial Zone Design Guide Palmerston North City Council June 2004

SECTION ONE North East Industrial Zone Design Guide Palmerston North City Council June 2004 SECTION ONE North East Industrial Zone Design Guide Palmerston North City Council June 2004 young heart easy living 1 Preface Industrial areas are a very important component of the economic well-being

More information

Air Entrainment Meter Type A CN025. Impact Test Equipment Ltd & User Guide. User Guide

Air Entrainment Meter Type A CN025. Impact Test Equipment Ltd   &   User Guide. User Guide Air Entrainment Meter Type A CN025 Impact Test Equipment Ltd www.impact-test.co.uk & www.impact-test.com User Guide User Guide Impact Test Equipment Ltd. Building 21 Stevenston Ind. Est. Stevenston Ayrshire

More information

Motion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat

Motion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat Motion Detector Installation and Usage Guide The Motion Detector guards against intruders moving through your home, providing an additional layer of protection that is especially suited to guarding wide

More information

PLANNED UNIT DEVELOPMENT Date: April 5, 2018

PLANNED UNIT DEVELOPMENT Date: April 5, 2018 PLANNED UNIT DEVELOPMENT Date: April 5, 2018 DEVELOPMENT NAME SUBDIVISION NAME LOCATION Robert Myers Robert Myers 2955 and 2989 Dauphin Street (Southeast corner of Dauphin Street and Sage Avenue) CITY

More information

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Ryan Mohs, Process Engineer, All Flex. Flexible heaters are commonly utilized in many different heating applications. Generally, these

More information

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-7:2000+A1:2002+A2:2006 EN54-25:2008 0359 Electro Detectors Ltd. Electro

More information

GEOMEMBRANE FIELD INSTALLATION

GEOMEMBRANE FIELD INSTALLATION GEOMEMBRANE FIELD INSTALLATION CONTENTS Introduction Quality Control and Quality Assurance Types of lining systems Basic Lining Design Executive Lining Design Basic Lining Design Specification Executive

More information

Drawer Configuration Installation Guide

Drawer Configuration Installation Guide Configuration Guide IMPORTNT: Please read before you begin your drawer installation. The pages in this guide show you how to assemble the different drawer layouts available for Klëarvue Cabinetry. Look

More information

Plumber A Guide to Course Content

Plumber A Guide to Course Content Plumber A Guide to Course Content Plumbers install, replace and maintain water and sewage systems, and hydronic heating systems in residential, commercial and industrial buildings. They may also be licensed

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

DO YOU KNOW YOUR SOILS? (Rev. 10/11)

DO YOU KNOW YOUR SOILS? (Rev. 10/11) DO YOU KNOW YOUR SOILS? (Rev. 10/11) Circle all the correct answers. 1. What is the layer normally present on the surface of the soil in cropped fields? a. O c. Ap e. B g. R b. A d. E f. C 2. Available

More information

1. Build the inner walls

1. Build the inner walls 3D-Papercraft Buildings of the World Series France Arc de Triomphe (section ) C D. Japan, Inc. Canon R is a registered trademark of Canon Inc.. Build the base 3. Build the arch Canon 3D-Papercraft Mini-book

More information

Urban Design of Historic districts Based on Action Planning

Urban Design of Historic districts Based on Action Planning Urban Design of Historic districts Based on Action Planning College of Urban and Environmental Sciences,Northwest University, Xi'an 710127, China. 974702583@qq.com Abstract:Historical districts are faced

More information

OFFICE FURNITURE Desks & Conference Tables

OFFICE FURNITURE Desks & Conference Tables OFFICE FURNITURE Desks & Conference Tables 01992 709 420 www.gbnofficefurniture.co.uk DESKING Contemporary Design CREATIVE & PRACTICAL DESKING The majority of work-space is still dedicated to independent

More information

FLIR Optical Gas Imaging Camera Helps Improve Environment And Safety At Borealis Stenungsund

FLIR Optical Gas Imaging Camera Helps Improve Environment And Safety At Borealis Stenungsund FLIR Optical Gas Imaging Camera Helps Improve Environment And Safety At Borealis Stenungsund Many petrochemical plants handle invisible gaseous hydrocarbons. Most of these gases pose some sort of safety

More information

LIMITED LIFETIME WARRANTY

LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY To obtain Service, please contact or call Turn of the Century Service Department: 1-800-887-6326, 9 a.m.- 5 p.m. central time. Model No.: # 355-6782 The limited lifetime warranty

More information

Gas & Water Monitor Installation Manual

Gas & Water Monitor Installation Manual Gas & Water Monitor Installation Manual English Version 1.0, as of 7/12/2016 2013-2016 Smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Blow Molding Machines for PC Water Bottles

Blow Molding Machines for PC Water Bottles Blow Molding Machines for PC Water Bottles KPC Series Blow Molding Machines for PC Water Bottles 1 2 Kautex Maschinenbau provides its customers with globally leading solutions in terms of quality, technology

More information

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C I] WHAT IS INFRARED? Infrared (IR) is a part of electromagnetic spectrum and lies just beyond red color of visible light. Infrared is invisible. However it has properties similar to light i.e. it travels

More information

Engineering canopy solutions that are built to last

Engineering canopy solutions that are built to last Engineering canopy solutions that are built to last An inside guide to site-specific calculations www.canopiesuk.co.uk CONTENTS 1 2 3 4 5 Calculating quality - the Canopies UK way. What are site-specific

More information

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation ECNDT 2006 - Poster 73 Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation Francisco J. MADRUGA, Daniel A. GONZÁLEZ, Jesús MIRAPEIX, José-Miguel LÓPEZ HIGUERA, Photonics Engineering

More information

CITY OF VANCOUVER ADMINISTRATIVE REPORT

CITY OF VANCOUVER ADMINISTRATIVE REPORT CITY OF VANCOUVER ADMINISTRATIVE REPORT Date: October 20, 2004 Author: David Desrochers Phone No.: 604.873.7893 RTS No.: 4716 CC File No.: 5802 Meeting Date: December 14, 2004 TO: FROM: SUBJECT: Vancouver

More information

Metal Turbine Exhaust Joints An analysis of metal and fabric GTX expansion joints

Metal Turbine Exhaust Joints An analysis of metal and fabric GTX expansion joints The expansion joints, for a large Westinghouse turbine, are used between a hot turbine diffuser and cold HRSG inlet; the internal gas temperature is 1100ºF average. The two fabrics have thermal monitors

More information

EN l Senking Batch Transfer Drying Tumbler DT Senking Batch Transfer Drying Tumbler DT High performance with less energy

EN l Senking Batch Transfer Drying Tumbler DT Senking Batch Transfer Drying Tumbler DT High performance with less energy EN l Senking Batch Transfer Drying Tumbler DT 60 240 Senking Batch Transfer Drying Tumbler DT 60 240 High performance with less energy Single dryer with loading belt. directly side by side. The dryers

More information

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax: 06-26-00 Page #1 of 6 This guide provides specific information about the material requirements, design criteria, assembly and testing methods recommended to assure a successful steam condensate return

More information

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-5:2000+A1:2002 EN54-25:2008 0359 Electro Detectors Ltd. Electro House Edinburgh

More information

Te c h S p e c 3. Edge Restraints for Interlocking Concrete Pavements

Te c h S p e c 3. Edge Restraints for Interlocking Concrete Pavements Te c h S p e c 3 Edge Restraints for Interlocking Concrete Pavements Introduction Edge restraints are an essential component of interlocking concrete pavements. Restraints hold the pavers tightly together,

More information

COMPARING PLASTIC STAKING TECHNOLOGIES

COMPARING PLASTIC STAKING TECHNOLOGIES COMPARING PLASTIC STAKING TECHNOLOGIES Jason Dornbos, Extol, Inc., Zeeland, MI Abstract Several thermoplastic staking technologies are available in the manufacturing industry. With many options to choose

More information

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings 0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric

More information

HIGH PRESSURE DOUBLE CASE PUMPS

HIGH PRESSURE DOUBLE CASE PUMPS HIGH PRESSURE DOUBLE CASE PUMPS Horizontally Split Inner Casing, Multi Stage For Boiler Feed, Process and Other High Pressure Services CS1860EE Models HSB/HDB API 610 HIGH PRESSURE DOUBLE CASE PUMPS Horizontally

More information

RIGID DC LIQUID CHILLER

RIGID DC LIQUID CHILLER RIGID DC LIQUID CHILLER Phone: +86-579-8837-9768 Email:info@rigidhvac.com Website: www.rigidchill.com 1 1. WHAT S LIQUID CHILLER? Liquid Chiller cooling refers to cooling by means of the convection or

More information

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION No Touch Thermometer Instant INSTRUCTION MANUAL THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION FEATURES 1. The No Touch Thermometer Instant is

More information

Gulfport, Mississippi 21 May 2007

Gulfport, Mississippi 21 May 2007 G PLUMBING GENERAL REQUIREMENTS The D-BC shall design the plumbing system to comply with this criteria and the Plumbing Code. Piping shall be shown on the same plan as the fixtures being served. Pipe size

More information

REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS

REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS CLAUDE DUMAS, CITY OF MONTREAL COSTAS LABOS, CITY OF MONTREAL CONSTANTINE PETROPOULOS, PBA 2 VICTOR SANTANGELO, PBA The information

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

A new age in HEATING. ROTEX Monopex The natural way to save energy! The complete heating system

A new age in HEATING. ROTEX Monopex The natural way to save energy! The complete heating system R A new age in HEATING R eco Systems - ROTEX EcoHybrid Heating for your home all from one source The complete heating system - Regenerative air-water Heating Pump - Modern burning Technique - Solar power

More information

Leakage detection in hydraulic and pneumatic systems through infrared thermography and CO2 as tracer gas

Leakage detection in hydraulic and pneumatic systems through infrared thermography and CO2 as tracer gas Leakage detection in hydraulic and pneumatic systems through infrared thermography and CO2 as tracer gas Borja Rodríguez 1, Rosario Fernández 1, Mario Lahera 2, Fernando Lasagni 1 1 Materials & Processes

More information

Urban regeneration vs. Urban sprawl Problems and prospects in the post-socialistic cities Piotr Lorens

Urban regeneration vs. Urban sprawl Problems and prospects in the post-socialistic cities Piotr Lorens Urban regeneration vs. Urban sprawl Problems and prospects in the post-socialistic cities Piotr Lorens Faculty of Architecture Gdansk University of Technology, Poland plorens@pg.gda.pl Presentation outline

More information

Geothermal ORC Systems Using Large Screw Expanders

Geothermal ORC Systems Using Large Screw Expanders Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Geothermal ORC Systems Using Large Screw Expanders Tim R. Biederman cyrq, United States

More information

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2 Products Solutions Services Food & Beverage industry Slide 2 Why is energy management an important topic? Energy prices influence production costs, End-consumer looks for sustainable products, companies

More information

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Apollo Intelligent Auto Aligning Beam Detector. User Guide Apollo Intelligent Auto Aligning Beam Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES FLAME AND GAS DETECTION FOR LNG FACILITIES Liquefied natural gas (LNG) is a generic name for liquefied hydrocarbon gas composed primarily of methane. When natural gas is cooled to approximately -260 F,

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009. SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for

More information

Welcome to Nola Electrical

Welcome to Nola Electrical PROFILE Welcome to Nola Electrical Nola Electrical has over 25 years experience with jobs ranging from small to multi-storey buildings - including hospitals, offices, universities, schools, hotels, apartments

More information