RapidDome Dome Owners Operating & Installation Guide

Size: px
Start display at page:

Download "RapidDome Dome Owners Operating & Installation Guide"

Transcription

1 RapidDome Dome Owners Operating & Installation Guide Document Code number Draft

2 Table of Contents Safety Instructions ii Setting up the RapidDome Dome 1 Wiring Details 1 Settings on the RapidDome Dome Top Board 3 Address Settings 4 Coax Telemetry 4 LED on the RapidDome Dome Bottom Board 5 Alarm Settings 5 Alarm / Relay Connections 6 Installing the RapidDome Dome 8 Installing the RapidDome Dome 8 Sample Configurations and Notes for Twisted Pair Installations 11 Technical Specification 13

3 Safety Instructions WARNING! Read these notes before attempting to operate the RapidDome Dome Refer all servicing to qualified personnel. These products are for internal use only. These products contain static electricity sensitive devices. Please take appropriate precautions when handling. Handle the RapidDome Dome with care, as improper handling may cause irreparable damage to the precision or sensitive parts within this unit. Never point the camera directly towards a bright light source (for example sunlight), or expose the camera to intensive light situations as this may damage the camera pick-up device. This information and our technical advice - whether verbal, in writing, or by way of trials - is given in good faith but without warranty and this also applies where proprietary rights of third parties are involved. Our advice does not release you from your obligation to check its validity and to test our products suitability for the intended purpose(s) and use(s). The application, use and installation of our products either in isolation or in conjunction with other products used, provided and/or installed by you on the basis of our technical advice are beyond our control and therefore remain entirely your own responsibility. Ademco Video products are sold in accordance with our General Conditions of Sale and Delivery. ALL DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Ademco Video 2000

4 Wiring Details Setting up the RapidDome Dome Mounting The RapidDome Dome is designed for speed of installation and set up and so the wall and ceiling mount brackets are supplied pre-wired. Customer wiring is via an internal terminal block PCB that is located inside the base plastic cover. (See for the location of the terminal block and for the wiring details.) The false ceiling versions of the RapidDome Dome are supplied with a 3m cable. Wall & Ceiling Mount WALL MOUNT BRACKET VC5S-WB CEILING MOUNT BRACKETS 54mm 12mm WIDE SLOT FOR CABLES ON R30 80mm * * 161mm 42mm 80mm 142mm 82mm 100mm SQ

5 SG SYN D- D+ CON3 CON2 VC 408 CON1 VID VG +V 0V Mounting Options for RapidDome Dome (including detail of the terminal block) TWISTED PAIR UP-THE-COAX CONTROL SG (Not Used) SG (Not Used) SYN (Not Used) SYN (Not Used) D+ Twisted D+ (Not Used) Pair D- Control D- (Not Used) VID Video Signal VID Video Signal VG Video Ground VG Video Ground +V (AC) 24V AC +V (AC) 24V AC 0V (AC) 24V AC 0V (AC) 24V AC False Ceiling Mount Wiring Details for the RapidDome Dome (False Ceiling Mount) Solder side view of connector fitted on 3 meter supplied cable TWISTED PAIR DATA IN COAX Pin 1 Green 24V AC Pin 1 Green 24V AC Pin 2 Red 24V AC Pin 2 Red 24V AC Pin 3 Blue Data + Pin 3 (Not Used) Pin 4 Yellow Data - Pin 4 (Not Used) Pin 5 Coax Screen Video Ground Pin 5 Coax Screen Video Ground Pin 6 Coax Core Video Signal Pin 6 Coax Core Video Signal Pin 7 (Not Used) Pin 7 (Not Used)

6 Settings on the RapidDome Dome Top Board In the following section, please refer to below, for the locations on the board. TERMINATION OFF ON LK1 DILSW1 - Jupiter Microsphere protocol, address setting DIL Switch. 1 8 VC 445V3 VC L D2 - Sys OK LED This LED is illuminated if the receiver is being controlled by Coax telemetry and is selected by the transmitter. If the receiver is being controlled by twisted pair, it will flash whenever a valid telemetry command is received. The RapidDome Dome Board LED D2 will illuminate if the receiver that is being controlled by Coax Control is selected by the transmitter and the coax control code is satisfactory. If the receiver is being controlled by twisted pair control, LED D2 will flash whenever a valid command is received.

7 Address Settings The addresses for each Dome are set as shown in the table below. Set the Poles on DILSW 1 to the desired position for each address. DIL SW ITC H SE TTING S DIL SW ITC H SE TTING S DIL SW ITC H SE TTING S DIL SW ITC H SE TTING S Cam No Denotes the sw itc h p o sition, where = O N & = O F F Cam No Denotes the sw itc h p o sition, where = O N & = O F F Cam No Denotes the sw itc h p o sition, where = O N & = O F F Cam No Denotes the sw itc h p o sition, where = O N & = O F F

8 Coax Control Up-the-Coax RapidDome Domes do not require an address setting; therefore the settings of positions 1-7 on DILSW1 are ignored. Position 8 controls the alarm feature as described in Section 7. LED on the RapidDome Dome Bottom Board In the following section please refer to below for the locations on the board. D19 DATA D19 - Data Received LED Flashes whenever a valid telemetry command is received The RapidDome Dome Bottom Board LED D19 will flash each time a valid control command for this receiver is received. Alarm Settings Switch 8 of the 8 way DIL switch (DILSW1: see on page 3) is used to toggle the RapidDome Domes alarm setting. When the switch is ON the RapidDome Domes alarm inputs are enabled and set to the default settings as shown in the table below. If switch 8 is OFF then the alarms are not automatically enabled, but can be enabled and adjusted using a MaxCom with local alarm menus. (See the MaxCom instructions for details of alarm setting menus.)

9 Default Alarm Settings ALARM INPUT-TYPE PRESET TIME OUT 1 Normally Open 1 10 Seconds 2 Normally Open 2 10 Seconds 3 Normally Open 3 10 Seconds 4 Normally Open 4 10 Seconds 5 Normally Open 5 10 Seconds 6 Normally Open 6 10 Seconds 7 Normally Open 7 10 Seconds 8 Normally Open 8 10 Seconds When an alarm input becomes active, the RapidDome Dome will move to the corresponding preset and Relay 1 will close its contacts. When the alarm time-out has expired the RapidDome Dome will return to its pre-alarm state and Relay 1 will open its contacts (provided no other alarms have been activated and are still timing out). Alarm / Relay Connections The connections to the alarm inputs and relay output are via 2 RJ45 sockets located at the top of the RapidDome, shown below.

10 Connector 3 Connector 2 Top View of RapidDome with Alarms The connections on the RJ45 plugs are numbered as shown below. A suitable termination tool will be required to connect to the RJ45 plugs. Contacts 8 Cable 1 Contact Side View of RJ45 Plug The 2 RJ45 connectors are wired as shown in the table overleaf. CONNECTOR 2 CONNECTOR 3 PIN SIGNAL PIN SIGNAL 1 Alarm in 1 1 Alarm in 5 2 Alarm in 2 2 Alarm in 6 3 Alarm in 3 3 Alarm in 7 4 Alarm in 4 4 Alarm in 8 5 Alarm Common 5 Alarm Common 6 Relay 1 N/O 6 Relay 2 N/O 7 Relay 1 Common 7 Relay 2 Common 8 Relay 1 N/C 8 Relay 2 N/C (N/O = Normally Open, N/C = Normally Closed.)

11 Relay 2 is controlled by a MaxComs 0 AUX momentary function and can be used to control auxiliary equipment. The maximum current rating for the 2 relays is 24V DC or 120VAC Installing the RapidDome Dome When handling the RapidDome Dome, DO NOT touch the acrylic, or any sensitive or precision parts, as this will cause damage to the unit. Installing the RapidDome Dome Ceiling and Wall Mounted Models Details of the ceiling and wall mount brackets, including dimensions. WALL MOUNT BRACKET VC5S-WB CEILING MOUNT BRACKETS 54mm 12mm WIDE SLOT FOR CABLES ON R30 80mm 161mm 42mm 80mm 142mm 82mm 100mm SQ Mounting Brackets for RapidDome Dome Step 1 Attach the bracket (wall or ceiling type) using fixings which are appropriate for the surface and able to support the weight of the RapidDome Dome (1.1 kg).

12 PUSH UP POLE ALIGN LUG TO SLOT Fitting the RapidDome Dome into the bracket Step 2 Align the lug on the RapidDome Dome with the slot on the bracket. Carefully push the RapidDome Dome into the bracket and twist clockwise. Allow to drop into the retainer. PUSH UP TWIST Fitting the RapidDome Dome into the bracket 3 Fit the M3 CSK safety locking screw into the bracket to lock the RapidDome Dome in place. This is ESSENTIAL for the safe operation of the RapidDome Dome. (The hole for the screw is on the opposite side of the pole to the slot.) 4 Attach the cable cover. This is supplied as two halves that snap together over the neck of the RapidDome as shown below.

13 C able C over 2 havle s sn a p to g e ther Fitting the Cable Covers When the RapidDome Dome is to be fitted to a JD5S80 (80mm) mounting pole, then the hole in the cable cover will need to be aligned with the screw hole in the pole when fitting the M3 CSK safety locking screw as shown below. ALIGN HOLE WITH SCREW HOLE FIT LOCKING SCREW Fitting the M3 CSK locking screw False Ceiling Model The RapidDome Dome is designed to be mounted in a flat ceiling installation. Mounting the RapidDome Dome in an angled ceiling installation will affect the units center of gravity and, consequently, programmed tours will be affected. The false ceiling kit requires a clear area of 270mm diameter for installation. See below for details

14 50mm (2 ) LANYARD RETAINING DISC 145mm (5.8 ) 148mm (5.9 ) 75mm (3 ) 270mm (10.7 ) Dimensions Required for False Ceiling Kit Step 1 Ensure that the false ceiling is able to support the weight of the false ceiling kit. (1.25 kg) 2 Using the retaining ring as a template, cut a 160mm diameter hole in the ceiling using an appropriate tool. 3 Drill three 6mm holes on the 186mm PCD to accept the mounting studs. 4 Follow the installation diagram in to fit the Lanyard. Ensure that the Lanyard is fitted correctly at the point indicated. (Point A.) 5 Insert the RapidDome Dome through the ceiling and fit the retaining disk to the back of the RapidDome Dome. (The rear of the ceiling face). 6 Screw down the three M4 Nyloc nuts to lock the RapidDome Dome into place

15 Lanyard A M3 Screw and washer M4 Nyloc nut and washer DO NOT OVERTIGHTEN M4 Nut Fitting the Lanyard Sample Configurations and Notes for RS485 Twisted Pair Installations Individual Twisted Pair Output If a single RapidDome is to be connected to an individual twisted pair output, then the link should be fitted across pins 1 and 2 on LK1. This sets the termination to ON. See below for a sample Configuration RS485 from Transmitter or ADCD16TP KEY = Data + = Data - Shield Insulate Shield Do NOT connect shield to RapidDome Yellow Blue RapidDome Dome Termination LK1 across pins 1 and 2 (Termination on) Individual Twisted Pair Output Twisted Pair and Daisy Chain connections Twisted pair RS485 RapidDome Domes may be daisy chained up to a maximum of 32 units from a single twisted pair RS485 output. When this option is used, it is imperative

16 that the termination link LK1 is set correctly. In a chain of RapidDome Domes, the link MUST be fitted across pins 2 and 3 (termination OFF), for all domes in the chain except the final one. The link MUST be fitted across pins 1 and 2 of the last RapidDome Dome, (termination ON). Below shows a system using two RapidDome Domes in this way. Star Connections DO NOT connect several twisted pair RS485 telemetry receivers in a Star Connection to one twisted pair output using long cables - use the daisy chain method detailed above instead. If separate cables are brought back from the RapidDome Domes to the transmitter then the ADCD16TP MUST be used to provide individual RS485 output to the cameras. ADCD16TP must also be used in systems that have more than 32 RapidDome Domes.

17 Connect shiel of RS485 cable to transmitter ground. Connect shield to all segments of Daisy Chain Do not connect shield to RapidDome Dome WARNING A fault in the wiring can cause all of the RapidDome Domes in the chain to fail or malfunction This distance is to be as short as possible (less than 3m) RS485 from Transmitter or ADCD16TP Shield KEY = Data + = Data - Use insulated screw terminals or crimps to join cables close to RapidDome Dome Yellow Blue Shield RapidDome Dome Termination LK1 fitted across pins 2 and 3 (termination off) DO NOT connect shield to RapidDome Dome Any intermediate RapidDome Domes would have termination link LK1 set to link pins 2 and 3 (termination off) Maximum of 32 RapidDome Domes in daisy chain Insulate Shield Yellow Blue Last RapidDome Dome in chain - Termination LK1 fitted across pins 1 and 2 (termination on) DO NOT connect shield to RapidDome Dome Daisy Chain Installation

18 The above rules concerning the use of RS485 must be adhered to so that the control data is not corrupted. Failure to adhere to these rules will seriously reduce the performance of the RapidDome Dome

VIDEO CONTROLS LIMITED

VIDEO CONTROLS LIMITED VIDEO CONTROLS LIMITED MAXCOM PRO SERIES TELEMETRY CONTROL SYSTEMS Operation Guide for use with MaxCom 3V, MaxCom 3VE, MaxCom 4V and MaxCom4VE Document Code number - CI431V2 Table of Contents Safety Instructions

More information

Model Number. Installation Manual. Internal Orbiter Microsphere. Publication No. - HMDI May Rev. A

Model Number. Installation Manual. Internal Orbiter Microsphere. Publication No. - HMDI May Rev. A Model Number Internal Orbiter Microsphere Installation Manual ISSUE DATE REVISIONS A May 2004 Initial Release Page i FCC COMPLIANCE STATEMENT INFORMATION TO THE USER: This equipment has been tested and

More information

5 Inch Speed Dome Installation Manual V2.0.0

5 Inch Speed Dome Installation Manual V2.0.0 5 Inch Speed Dome Installation Manual V2.0.0 2010-01 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

Model AD C AD RS-422 Distributor

Model AD C AD RS-422 Distributor Model C AD RS-422 Distributor Installation and Operation Instructions Speed LT, Speed, Speed Ultra, Speed Optima, and Speed Optima LT The C Distributor is used to interface American Dynamics Switching

More information

6 Inch Speed Dome Installation Manual V2.0.0

6 Inch Speed Dome Installation Manual V2.0.0 6 Inch Speed Dome Installation Manual V2.0.0 2010-01 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS PAGE 2 of 24 AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1.0 CONTENTS PAGE Manual introduction 4 System introduction

More information

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents.   What to Expect with. Mounting Options. Tools Needed Table of Contents www.hunterfan.com What to Expect with Your Installation Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Networked Access Control Panel. Installation Guide

Networked Access Control Panel. Installation Guide XP2M Networked Access Control Panel V1.0X Installation Guide X P 2 M A C C E S S C O N T R O L S Y S T E M Installation Guide Document Ref: PLAN XP2M Installation Guide V4(G)2010 Access Control Services

More information

LeakSafe. solutions. WaterSwitch2. Installation Instructions

LeakSafe. solutions. WaterSwitch2. Installation Instructions LeakSafe solutions TM WaterSwitch2 Installation Instructions WATERSWITCH2 COMPONENTS WaterSwitch2 Valve Control Extended Range Valve Driver Valve Water Flow Sensor Leak Detection tape available in 0.3M

More information

LPCMPIRM65 & LPCMPIRDSI65

LPCMPIRM65 & LPCMPIRDSI65 Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL MANUAL NUMBERS 517646-1960 517645-1960 517702-1960 517783-1960 Ultrak, Inc. 4465 Coonpath Road NW Carroll, OH 43112 (740) 756-9222

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2

More information

Outdoor Housing PIH-510 H/L/G & 510 H/L/G IP INSTRUCTION MANUAL

Outdoor Housing PIH-510 H/L/G & 510 H/L/G IP INSTRUCTION MANUAL Outdoor Housing PIH-510 H/L/G & 510 H/L/G IP INSTRUCTION MANUAL IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before the unit is operated. 2. Retain

More information

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225. Gasflag Single Channel Control Panel Alarm Only Apparatus Installation, operating and maintenance instructions, M07225 Issue 2 1/07/05 Crowcon Detection Instruments Ltd 2 Blacklands Way Abingdon Business

More information

Infrared Wall Mount Occupancy Sensor

Infrared Wall Mount Occupancy Sensor LOS-WI LOS-WI-1 02.01.06 Infrared Wall Mount Occupancy Sensor The LOS-WI wall-mounted passive infrared sensor is used in spaces with pendant fixtures, ceiling fans, or high ceilings (more than 12 feet).

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

RCS Residential Control Systems Inc.

RCS Residential Control Systems Inc. RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following

More information

52 CEILING FAN. Owner s Manual Models #50336, 50337

52 CEILING FAN. Owner s Manual Models #50336, 50337 52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

RC-2000 Thermostat Installation Instructions

RC-2000 Thermostat Installation Instructions RC-2000 Thermostat Installation Instructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC heating and cooling systems. The RC-2000 will support the following systems: Single

More information

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed. Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

VPS3 Installation Manual

VPS3 Installation Manual 1-512-756-1678 VPS3 Installation Manual VPS3 Viewer (Local Unit) VPS3 Sender (Remote Unit) Content Introduction...2 Features...2 Packing Checklist...2 Patents...2 Limited Warranty...2 Overall Certificate...3

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

Product Manual SZ1145

Product Manual SZ1145 Product Manual SZ114 General Purpose Monitor Communicating Controls Description The SZ114 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum temperature

More information

D-Tect 2 GJD300 Quad PIR Movement Detector

D-Tect 2 GJD300 Quad PIR Movement Detector D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x

More information

Operating Instructions

Operating Instructions Operating Instructions System 57 Module Kit (05701-A-0309) Alarm Update Panel (05701-A-0339) Helping to make a safer world Ensure that you read and understand these instructions BEFORE operating the equipment.

More information

52 BERKSHIRE CEILING FAN

52 BERKSHIRE CEILING FAN 52 BERKSHIRE CEILING FAN Owner s Manual Models #20223, 20224 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9

More information

LeakSafe. solutions. WaterSwitch2. Installation Instructions

LeakSafe. solutions. WaterSwitch2. Installation Instructions LeakSafe solutions TM WaterSwitch2 Installation Instructions QUICK USER GUIDE 1. Turning water ON or OFF using the WaterSwitch Valve Control To turn the water ON, press and hold down the WATER ON button

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Manufacturer of Medical Gas Pipeline Equipment Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Master Alarm Conversion Combination Alarm

More information

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions Bulletin E-97DC Thank you for purchasing the Dwyer DCT1000DC Dust Collector Timer Controller. You

More information

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Manifold Installation Controller MIC-180. Installation and Operation Instructions Manifold Installation Controller MIC-180 Installation and Operation Instructions For Use With Rheem-Ruud and Paloma Commercial Tankless Water Heaters Table of Contents Safety Information... 1-2 Manifold

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

Product Manual SZ1144

Product Manual SZ1144 Product Manual SZ1144 Refrigeration Temperature Monitor Communicating Controls Description The SZ1144 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents.   What to Expect with. Tools Needed. Mounting Options. Blades Table of Contents 1.888.830.1326 Ceiling Bracket 30 inches Ladder Downrod 3 Wiring 10 Operation, Maintenance & Cleaning Light Kit 11 Troubleshooting??? 17 15 1 13 5 Blades 9 Switch Housing 12 Canopy 6

More information

Installation Instructions

Installation Instructions Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4 EMS510 Electrical Wiring Guide Volume 2, Rev 1.4 Prepared by Michael L. Kominske Environmental Monitor Service Inc. PO Box 4340 Yalesville, CT 06492 Phone 203.935.0102 Fax 203.634.6663 Email: sales@emsct.com

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information

Electrician Installation Manual EM-E Ceiling Fan

Electrician Installation Manual EM-E Ceiling Fan Electrician Installation Manual CEILING FAN MUST BE INSTALLED BY A LICENSED ELECTRICIAN (NO OTHER PERSONS SHOULD ATTEMPT TO INSTALL THIS FAN) *Electricians are recommended to tick off all items on the

More information

OWNERS INSTRUCTION MANUAL

OWNERS INSTRUCTION MANUAL OWNERS INSTRUCTION MANUAL 132CM/52 Classic INSTALLATION OPERATION MAINTENANCE CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN SUITABLE

More information

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL READ AND SAVE THESE INSTRUCTIONS MODEL: 52-771-5TK-13 52-771-5BW-SN 52-771-5WH-WH FAN RATING AC 120V. 60Hz CUL LISTED MODEL : AC-552A 1. TOOLS AND MATERIALS REQUIRED Philips

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual Contents I. SPECIAL FEATURES 1 II. FRONT PANEL 1 III. INSTALLATION PROCEDURES AND PROXIMITY CARD TYPES 2 IV. SETTING

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction Hoffman Controls Installation & Operating Instructions Introduction CAUTION Failure to read and understand the accompanying instructions and diagrams prior to energizing the Controller may result in permanent

More information

52 STRATHMERE CEILING FAN

52 STRATHMERE CEILING FAN 52 STRATHMERE CEILING FAN Owner s Manual Models #20341 If a problem cannot be remedied or you are experiencing difficulty with installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

RTD-10 Installation Instructions

RTD-10 Installation Instructions LED3 SW1 LED4 LED5 LED6 RTD-10 Installation Instructions +V S5 S6 POWER 15-24VDC English RTD-10 Installation Instructions 100.00 RTD-10 Control Interface realtime Control Systems 24VAC/3DC, 1A REMC P1

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504 Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

INTELLEX KIT (CTI Interface) Installation Guide

INTELLEX KIT (CTI Interface) Installation Guide INTELLEX KIT (CTI Interface) Installation Guide Building Block Video Ltd 17 Apex Park, Diplocks Industrial Estate Hailsham, East Sussex, BN27 3JU, UK Tel: + 44 (0) 1323 842727 Fax: + 44 (0) 1323 842728

More information

IR Intelligent Positioning System Installation Manual

IR Intelligent Positioning System Installation Manual IR Intelligent Positioning System Installation Manual Version 1.0.0 Table of Contents 1 INSTALLATION PREPARATION... 1 1.1 Basic Requirement... 1 1.2 Installation Check... 1 1.3 Cable Preparation... 1 1.3.1

More information

DUAL OPTIC. Installation manual

DUAL OPTIC. Installation manual DUAL OPTIC Installation manual INDEX 1 COMPONENTS Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 CABLES AND CABLING Pag. 7 CONNECTION AND HEATING SETTING

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/

More information

POWER SHOWERS Models 4500M 5002M 4500T 5002T

POWER SHOWERS Models 4500M 5002M 4500T 5002T II POWER SHOWERS Models 4500M 5002M 4500T 5002T Performance Shower Products CUSTOMER SERVICE HELPLINE: 01883 730339 CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY: This booklet covers all models in

More information

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Installation Manual for Hot Yoga Studio Electric Radiant Heating 105 Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/

More information

3SA60 3SA60+LED. Vogue & Vogue Plus. Net weight. This instruction contains 11 pages:

3SA60 3SA60+LED. Vogue & Vogue Plus. Net weight. This instruction contains 11 pages: Vogue & Vogue Plus 3SA60 3SA60+LED This instruction contains 11 pages: Page 1: Foreword Page 2~3: Unpack and inspect parts contained Page 4~5: Notes before installation and Hanging system installation

More information

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1 SmartTerminal AS7240 Installation and Operation Guide MAN2990-1 Table of Contents Page No. 1 Introduction... 3 2 Mechanical... 4 2.1 Mounting the Enclosure... 4 2.1.1 Enclosure Details... 4 2.1.2 Fixing

More information

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Table of Contents.   What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring. www.hunterfan.com Table of Contents What to Expect with Your Installation Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many

More information

ORION Mini-Rep INSTALLATION MANUAL

ORION Mini-Rep INSTALLATION MANUAL ORION Mini-Rep INSTALLATION MANUAL Orion Mini-Rep - INSTALLATION MANUAL - REVISION 1.0-04/007 The Orion Mini-Rep will provide remote control and system display status from multiple locations to an Orion

More information

C-RM700 REMOTE CONTROLLER OPERATING INSTRUCTIONS

C-RM700 REMOTE CONTROLLER OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS REMOTE CONTROLLER C-RM700 Thank you for purchasing TOA's Remote Controller. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

More information

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool Document Number 13I00-4 January, 1997 Copyright 1997 Home Automation,

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

EG-400 Fire Detection Monitor

EG-400 Fire Detection Monitor EG-400 Fire Detection Monitor For Engine and Generator compartments Owner s manual with installation instructions Revision 2.3 (10/1/07) Our Business is Your Safety and Peace of Mind! Jim Shepherd Toll

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems

Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems Master Alarm Area Alarm Andersen Medical Gas 12 Place

More information

CommStat 4 Controller

CommStat 4 Controller CommStat 4 Controller CommStat 4 Telecom HVAC Controller The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners, heat pumps and air conditioners with

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information. 3 Specifications.. 4 Main Power Connection..5 DMX-512 Connection...... 5 Rigging the Fixture... 6 Installation...6 Main Control Menu... 8 DMX Profile 9

More information

380 SERIES REMOTE SIREN ETSA380R

380 SERIES REMOTE SIREN ETSA380R ! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren sound outside of vehicle. Please

More information

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions DESCRIPTION The RC-90 is a precision digital thermostat designed for 24 VAC single stage heating and

More information

48 TAYLOR CEILING FAN

48 TAYLOR CEILING FAN 48 TAYLOR CEILING FAN Owner s Manual Models #20554 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.- 5 p.m.

More information

Dual Function Bowl Light Kit

Dual Function Bowl Light Kit Dual Function Bowl Light Kit Owner s Guide and Installation Manual Manual De Propietario English Español Form# 43550-01 20100610 2010 Hunter Fan Co. Welcome Your new Hunter light kit is an addition to

More information

LUCCI AIRFUSION RESORT DC CEILING FAN

LUCCI AIRFUSION RESORT DC CEILING FAN LUCCI AIRFUSION RESORT DC CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V 2. 0 p u b l i c a t i o n o

More information

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds Fireray 2000 pplication and FETURES Installation Guide Range 10-100 metres 12V to 24V dc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or automatic reset

More information

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT) LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT) USER MANUAL AUSTRALIAN ELECTRICAL AUTHORITY CS96313V IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND LEAVE THIS MANUAL FOR

More information

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1

More information

Installation Manual. Models 99168, 99169, 99170

Installation Manual. Models 99168, 99169, 99170 Wet-Rated Globe Fitter Installation Manual Compatible with: 2xxxx Types A - Z 51000-58999 fan series 59500-59999 fan series Select Casablanca Fans Models 99168, 99169, 99170 BEFORE YOU BEGIN Read entire