1 Leaks monitoring systems CPTML01 series AT39102 INSTALLATION AND USE MANUAL _ PUBLIC CODE AT02301MI REV. 21 BY 11/16

2 Index INTRODUCTION 3 GENERAL WARNINGS 3 MARKING (INTRINSECALLY SAFE VERSION) 3 REQUIREMENTS CONCERNING THE INTRINSIC SAFETY EQUIPMENT 3 DOCUMENT DESCRIBING THE INTRINSIC SAFETY SYSTEM 3 INTRINSIC SAFETY SYSTEM DIAGRAM 4 DESCRIPTION OF PRODUCT 4 MAIN COMPONENTS 5 INSTALLATION 6 ELECTRICAL CONNECTION SENSORS AND ACCESSORIES 9 ELECTRICAL CONNECTION OUTPUT 13 GSETUP 14 OPERATING 16 ALARM SIGNALS TEST 18 SMS MANAGEMENT 18 CPT09012/I/A INTRINSICALLY SAFE BARRIER CONFIGURATION 18 SENSORS 19 ACCESSORIES 21 OPTIONS 22 SPARE PARTS 23 ACCESSORIES FOR THE SYSTEM 24 EXAMPLE OF APPLICATION 24 EU DECLARATION OF CONFORMITY 25/27/29/31 For information requests and technical assistance contact the freephone number (from Monday to Friday 8:00-12:00 / 13:00-17:00) NB: Within its respect for its quality commitment, Assytech S.r.l. reserves the right to vary or modify its products and the data included in the following manual. This catalogue must not be reproduced, even partially, without prior authorization. Installation and use Manual CPTML01 System PAGE 2

3 INTRODUCTION The manual provides all the necessary instructions for the installation and use of the leaks monitoring systems. GENERAL WARNINGS Before operating on this equipment, carefully read the instructions contained in this manual. The manufacturer cannot be held liable for any operations performed but not included in this manual. In the event of faults or malfunctioning of the instrument, please exclusively contact the company authorized to perform the maintenance or the manufacturer directly. The manufacturer declines all responsibility for any damage to people and/or items resulting from failure to observe the safety instructions. It is considered that all operators of the equipment are aware of the safety regulations relative to the product described in this manual. In the event of any doubts on the operation of the instrument, please exclusively ask the company authorized to perform the maintenance or Assytech directly for instructions. Any tampering with the instrument holds the manufacturer harmless from all responsibility towards the competent bodies. Caution! This product is used on fuel tanks and in environments at risk of explosion and fire. Tanks with underground leaks can cause severe damage to the environment and to people. MARKING (INTRINSECALLY SAFE VERSION) II (1) G [Ex ia] IIC T4 The equipment complies with the essential safety requirements of the following EU directives:: 2014/34/EU 2014/30/EU 2014/35/EU Its construction is in accordance with the following rules: EN EN EN REQUIREMENTS CONCERNING THE INTRINSIC SAFETY EQUIPMENT The electronic equipment contains the Ex barriers and is part of an intrinsically safe system. It must be installed outside the hazordous area and maintained in accordance with the intrinsically safe systems standards EN and maintenance standards EN , or with other national standards. The sensors, described in the manual supplied with the unit, can be installed in hazardous areas. All connections must be made in accordance with the provisions of standard EN , as indicated by the wiring diagrams supplied with the equipment. No changes to the wiring is not permitted without prior authorization from the manufacturer. Connect the ground wire to the terminals provided. Before powering the equipment, make sure that the supply voltage values correspond to those indicated on their circuit diagrams or the user manual. Before carrying out any work, disconnect power supply to prevent any damage to operators or arcing or sparking. Remove the main power supply before opening the power supply boxes of electronics. The spare parts used must be exclusively those provided by the manufacturer. DOCUMENT DESCRIBING THE INTRINSIC SAFETY SYSTEM The standard EN defines an "electrical system intrinsically safe" as an assemled set of interconnected electrical apparatus, which must be described in a "Document describing the" system, in which the circuits (or parts of circuits) to be used in a potentially explosive atmosphere, are intrinsically safe circuits. On this document, the charged project designer, through the knowledge of the electrical parameters: intrinsically safe certified devices associated certificated electric devices non-certified simple apparatus (electrical) the connection wires Installation and use Manual CPTML01 System PAGE 3

4 must ensure and declare, under his own responsibility and without any ambiguity, that the storage limits of the intrinsic safety features of the system are not exceeded. In the practice, this plant system analysis, has the aim to define the maximum length of the connection cables, depending on the characteristics of the cables themselves and of the associated apparatus, in order to ensure, in any considered condition, the intrinsically safe protection for the whole system composed of sensor / cable / Ex-i barrier. INTRINSIC SAFETY SYSTEM DIAGRAM The Ex equipment (sensor) can also be identified as "simple electrical construction", (S.A) if that meets the requirements in the standards EN and may not be certified by an Atex Notified Body if it lacks its own ignition sources. DESCRIPTION OF PRODUCT The system allows the management of up to 28 inputs (tanks, pipelines, wells and tanks dispensers), 8 of which are intrinsically safe. Thanks to the advanced technologies of the software, the system can be configured to perform different functions (monitoring, reporting, alarm etc.), according to the characteristics and needs of the system. The AT39102 control unit is enclosed in a metal container wall; is able to interface to a remote system, and its basic version allows the management of 4 inputs for sensors and 4 relays. Note: the AT39102 control unit can also be programmed using a special software installed on a PC and connected to the serial (See chapter: GSETUP) Technical characteristics Voltage VAC 50/60 Hz Barrier Ex-i parameters Max consumption 25 VA N of level sensors 4 20 Tank Pipes Tanks well Type of level sensors Dispensers well Sensors connection ON/OFF BUS RS485 Relays outputs 4 With RS232 / LAN / GSM/GPRS Remote data connection interfaces Operating temperature -10 C +40 C Dimensions 310X95H260 mm Marking II (1) G [Ex ia] IIC T4 (Intrinsically safe version) s AT39102 /N OF SENSORS / SENSOR TYPE /VERSION /4 /8 /12 /16 /20 /IA: Explosion proof /IS: Intrinsically safe /IM: Ex ma IIC IIB IIA Uo = 27,84 V Io = 0,068 A Po = 0,431 W Lo = Co = Inductance / capacitance applicable IIC IIB IIA Lo = 8 mh 30 mh 75 mh Co = 0,084 µf 0,0654 µf 2,16 µf /A: base Installation and use Manual CPTML01 System PAGE 4

5 MAIN COMPONENTS The equipment comprises a feed unit (1), complete with filter network and power supply, from a management main board (CPU) (2) which includes, in addition to the levels of reading and alarm circuit and the serial outputs of control of the various devices associated with it (PCs, printers, etc.), 4 auxiliary inputs, 4 outputs relays and 1 output 12 VDC. No. two additional optional interfaces (3) allow you to manage other 16 inputs. In intrinsically safe version (/IS), 1 or 2 intrinsic safety barriers (4) provide the "intrinsic protection" of any connected sensors (1 for managing up to 8 inputs / 2 for the management of more than 8 inputs). In the Ex-ma version the device can be interfaced to the equipment through a protection circuit (4B) without the use of Zener barriers. Finally there are several different serial interfaces for the connection of the control unit to the remote devices. SCHEDAC.P.U. DISPLAY TASTIERA AREA Ex A CLASSIFIED SICUREZZA INTRINSECA AREA 3 0 CN2 CN1 RX/TX DATA FLOW COPTRON SOC.COOP. Via Industria, Morbegno (SO) Italy DEVICES 1 STATUS + A B - RS485 CLOSE LOOP + CN2 B A - CN3 COM2 COM3 SENSORI COM1 1 J4 J2 SW L In - SENSORE 1 SENSORE 4 SENSORE 6 CN5 CN7 Switch Interruttore 5 SENSORE 2 SENSORE 5 SENSORE 7 POWER ALIMENTATORE SUPPLY SENSORE 3 SENSORE 8 CPTA Cavo di alimentazione elettrico V VAC AC alimentation cable Pos. Component 1 Power supply AT Principal board (CPU) AT inputs expansion AT A Intrinsically safe barrier for 8 Namur ON/OFF 4-20 ma inputs CPT09012/I/A 4B Protection circuit for Ex m sensor AT17511/A 5 Alimentation cable CA Installation and use Manual CPTML01 System PAGE 5

6 INSTALLATION General warnings If mixed with air, flammable vapours can cause explosive atmospheres. This can lead to hazardous areas due to the presence of gases or vapours. Explosions and fires can cause serious damage or even death. The AT39102 control unit is not explosion-proof. Do not install the control unit in a hazardous place. Installation location When choosing the installation location, it must be considered that the AT39102 control unit must be protected against vibrations and extreme climatic conditions (particularly high temperatures, humidity, etc.) which could alter its electric devices. Fixing To fix the control unit to the wall as follows: 1. Fixing the device with 4 plugs from 5 mm 2. Connect the sensors to the terminals as described in the chapter "Electrical connections sensors and accessories" GSM/GPRS modem installation 1. Insert the GSM module into the special dedicated slot 2. Insert the SIM card in the special slot of the GSM modem, following instructions shown on the modem Fessura per inserimento tessera 3. Start the control unit 4. Check the network connection status on the main display: 01 < DIAGNOSIS MENU > 03 GSM Signal: % Electrical connection To make the electrical connection of the AT39102 control unit, proceed as follows. Switch off all the power supply switches on the electric panel. Make the connections between the power supply panel and the control unit using the relevant connectors. To connect to the driving force, use a cable with three conductors of at least 1.5 mm 2 (phase, neutral and earth) suitably protected. The cable to be used for intrinsically safe sensors must be blue. Refer to the rules relating to circuits with Intrinsically Safe protection Protection circuit Protection circuit to be connected to the level switch with Ex ma protection mode. The circuit specifications are indicated in the manual. Installation and use Manual CPTML01 System PAGE 6

7 Installation diagram The system shall be made by specialised personnel. Comply with safety regulations. Read carefully the instructions shown in this manual. Assytech declines all responsibility for damages and/or additional costs incurred if supplied instructions are not complied with. Note A Installation shall be carried out in compliance with CEI 64-8 and CEI EN standards. Note B The cables of the Zener barrier must comply with the provisions of Standards EN and IEC Note C Use cables that comply with provisions stated by regulations applicable in the Country of installation. CEI 64-8: Electric systems for equipment at rated voltage not above 1000 V AC and 1500 V DC. CEI EN (1998) CEI classification Electric constructions for explosive atmospheres in presence of gas. Part 14: Electric systems in places with explosion period for the presence of gas (other than mines). Cable safety prescriptions The sensors are installed in a hazardous areas, where there may be dangerous liquids and/or vapors. A incorrect installation can cause fire and / or explosion. For this reason, carefully observe the following: Read the instructions carefully. The pipes of the sensors must not contain any other circuit. The cables and conductors of the sensors must only enter in their designated locations. The power and signal cables must not enter in the intrinsic safety location of equipment. The low voltage in the control unit is considered intrinsically safe because it is separated from the high voltage. To maintain the safety is necessary that the sensor cables are installed in their own conduits, to be separated from the other pipelines. Installation and use Manual CPTML01 System PAGE 7

8 Wiring installation For the cable positionning, and to seal the connection points, follow these instructions: Use sealed and intrinsically safe cables, preferably in light blue color, with filler, CPT02101 code. Install the cables of the sensors inside the appropriated junction boxes, CPT15901 code. Use suitable cable glands to realize the connection between the sensor cables and the control unit. The cables will join directly to the control unit. Close the cover of the junction box. Connection to control unit Important The wiring must be realized in accordance with CEI 64-8 and CEI EN and in compliance with the precautions indicated in this manual. The maintenance of intrinsically safe circuits must be made in accordance with CEI Input/output cable positioning and identification The I/O terminals used with the devices connected to the control unit must be properly marked to avoid incorrect wiring. Since incorrect wiring can cause malfunction of the unit, it is recommended to identify the physical location and / or the type of device connected to each terminal. Output relay When using output relays, follow the indications below: Do not use relays to control circuits with higher currents than 1 A (resistive load) or for voltages over 24 VCC. Alarm relays cannot be used for process control. Sensors: installation Before starting to install the sensors, ensure that the conductors are arranged correctly to allow the necessary connections. Important To obtain an excellent incoming signal, avoid joins on the lines. The power supply line conduits must be separated from those of the signal lines. Installation and use Manual CPTML01 System PAGE 8

9 ELECTRICAL CONNECTION SENSORS AND ACCESSORIES - Connection of explosion-proof sensors to the control unit inputs - Connection of Ex ma sensors Protection circuit for Ex ma sensors code AT17511/A SHIELD Installation and use Manual CPTML01 System PAGE 9

10 - Connection of intrinsically safe sensors Intrinsically safe barrier for 8 Namur ON/OFF 4-20 ma inputs code CPT09012/I/A - Presence liquid sensors functional diagram Level sensor cod. CPTL07/S-D-B DOUBLE CONTACT DEVIATED CONTACT SIMPLE CONTACT BLACK WHITE RED GREEN BLACK WHITE RED BLACK WHITE RED WHITE BLACK (RED) (*) Installation and use Manual CPTML01 System PAGE 10

11 Miniature level sensor code CPTL07/P BLACK WHITE RED WHITE BLACK (RED) G 1/8" M 27,00 13,00 40,00 4,0 DEVIATED CONTACT SIMPLE CONTACT (*) 27,50 Tank cavity sensor code CPTL07/S/3/A/00/008/05 WHITE RED (BLACK) Gravity-activated leak sensor code AT38902/1-6/M 90 69,25 WHITE BLACK (RED) WHITE BLACK (RED) Installation and use Manual CPTML01 System PAGE 11

12 Optical sensor code AT20901/i blue brown black COLOR BROWN BLUE DESCRIPTION VDC GND Block diagram, vacuum switch and pressure switch Vacuum switch code AT01010 Pressure switch code AT N.A. N.C p 87 COM. Installation and use Manual CPTML01 System PAGE 12

13 ELECTRICAL CONNECTION OUTPUT Installation and use Manual CPTML01 System PAGE 13

14 GSETUP GSetup allows programming control units. GSetup offers various connection modes towards the level control units: RS232/RS485, GSM and Radio. Connect button Select communication channel Control Units connection To carry out the connection to control unit: - Select a communication channel RS232/RS485 or GSM - Select serial COM and press Connect button Select COM Port - Insert the telephon number if GSM communication: - The system connects to and displays the firmware version installed on the control unit Disconnect button Firmware version Disconnect To end the communication with the control unit press the button "Disconnect". Installation and use Manual CPTML01 System PAGE 14

15 Parameters reading To read the parameters of the control unit connected: - Press Read button Read button - The system shows Download complete and displays all parameters configurated on the control unit Write button Parameters writing To insert or modify the values of the parameters of the control unit connected: - Digit the values in the table - Press Write button - Select if to write all parameters or only parameters modified - At the end the system displays Upload completed Data and time uploading To update date and hour of the control unit connected: - Press Data-Time button Date-Time button Installation and use Manual CPTML01 System PAGE 15

16 OPERATING Startup At start up, the display shows: followed by: CONTROL UNIT CPTS04206 R. XX STATUS OK _ i XX = software revision installed (operational condition OK) Any alarms and/or warnings are displayed on the screen sequentially: X/N _ i _ DESCRIPTION _ X= alarm index N = number of active alarms To access the control unit operation menu, use the special buttons. Scroll menu items Scroll submenu items and exit (Esc) Scroll submenu items and confirm (OK) Main menu The main menu displays the status of equipment operation. To access the menu, press P3. 1. The display shows: 01 < DIAGNOSIS MENU > 03 Signal GSM: % 2. Select using keys and the second menu item 02 < DIAGNOSIS MENU > 03 AT command: 3. Select using keys and the third menu item XXXX program cycles 4. Press P2 to exit from Diagnosis menu 03< DIAGNOSIS MENU > 03 Fps: XXXX Advanced Setup To access the menu, turn on the power by holding down the "P4" button. 1. The display shows the first menu item: 01 < SETUP MENU > 03 Modify parameters 1. Press to access to editing parameters < SETUP: PAR. ID XXX > Description parameter XXX Installation and use Manual CPTML01 System PAGE 16

17 2. Select using keys and the parameter with desired ID (XXX) or digit ID with the keyboard (see the parameters table) 3. Press to access to value parameter < ID:XXX XXX/NNN > Parameter value 4. Select using keys and the index XXX of NNN 5. Press to modify the value of parameter using keyboard 6. Press to confirm. The system returns to the previous menu 7. Press to return at select ID parameter menu 8. Press to exit. The display shows: < SETUP: PAR. ID XXX > Descrizione parametro XXX < QUIT SETUP? > YES 9. Press (YES) to exit setup and save data 10. The system shows Attend and than the main menu NO 01 < SETUP MENU > 03 Modify parameters 11. Select using keys e the second menu item 02 < SETUP MENU > 03 Reset parameters 1. Select using keys and the second menu item < DELETE PARAMETERS? > YES NO 12. Press to reset de parameters. The uni twill restart automatically 13. Select using keys and the third menu item 14. Press to exit from menu Exit 03 < SETUP MENU > 03 Easy Setup To access the menu, turn on the power by holding down the "P1" button. 1. The display shows the first menu iem: 01 < EASY SETUP > 38 In. N XX Input type 2. Select using keys and the input XX desired (Barrier input local input, expansion input) (max 36) 3. Select using keys the type of input (pipe/ tank / tank well / dispenser well / silencing /_) 4. Select using keys and the next menu item 37 < EASY SETUP > 38 Language 5. Select using keys the language (italian / english / french) 6. Select using keys and the next menu item 38 < EASY SETUP > 38 Save and exit 1. Press to confirm and exit from menu Installation and use Manual CPTML01 System PAGE 17

18 Parameters tables ID Short Description Description ID000 In.Local Configured [NU:0 INPUT:1 ACK:2] Sets for each of the 20 local inputs the mode of use (not used, input, silencing input) ID001 In.Local Mode [NO:0 NC:1] Sets for each of the 20 local inputs the operation mode between normally open and normally closed ID002 In.Local Type[TUB:0 SER:1 PZ.S:2 PZ.E:3] Sets for each of the 20 local inputs the descriptive ID003 ID004 In.Local Txt Sms Alarms Tel Number ID005 ComPort: Modem Sets COM (1-4) for modem ID006 ComPort: Debug Sets COM (1-4) for debug ID007 ComPort: Setup Sets COM (1-4) for setup ID008 Language [ITA:0 ENG:1 FR:2] Sets the language Sets for each of the 20 local inputs a descriptive different than the default (ID002) Sets to 5 telephone numbers to which will be sent an SMS in case of alarm ID009 ComPort: Barr.CPT09012i Sets COM (1-4) for CPT09012 barrier ID010 ID011 In.Rem. Configured [NU:0 INPUT:1 ACK:2] In.Rem. Mode [NO:0 NC:1] Sets for each of the 20 remote inputs the mode of use (not used, input, silencing input) Sets for each of the 20 remote inputs the operation mode between normally open and normally closed ID012 In.Rem. Type[TUB:0 SERB:1 PZ.S:2 PZ.E:3] Sets for each of the 20 remote inputs the descriptive ID013 In.Rem. Txt Sets for each of the 20 local inputs a descriptive different than the default (ID012) ID014 ComPort: Tplo Sets COM (1-4) for CPT09012/I/A barrier ID015 Telemetry: AccessPointName Sets the Telemetry Access Point name ID016 Telemetry: ServerName Sets the Telemetry Servere name ID017 Telemetry: ID Station Sets the Telemetry ID Station ALARM SIGNALS TEST Holding down for 10 seconds, the P1 button simulates an alarm condition resulting in: switching on of red LED activation of the siren SMS MANAGEMENT The control unit can send a text message to the set numbers (ID004 parameter) each time an alarm is activated and / or restored. Alarm format: "Alarm ACTIVE/RESTORED: ALARM_DESCRIPTION" The unit also responds to the following SMS: _ "Info" responds with the Fw installed and the ID code of the sim _ "Were" responds with a list of active inputs CPT09012/I/A INTRINSICALLY SAFE BARRIER CONFIGURATION Set SW3 according to table: SW3 SWITCH XX00 ADDRESS 1 XX01 ADDRESS 2 XX10 ADDRESS 3 XX11 ADDRESS 4 Installation and use Manual CPTML01 System PAGE 18

19 SENSORS Level magnetic sensors Ex ma CPTL07/S-D-B Minimum level switch. Max. switching voltage Max. switching current Max. switching power AC/DC Cable type Operating temperature Output functions Protection degree Cable output Body material Float material Fixing Execution Main characteristics 28,8 VCA 28,8 VDC 0,5 A 30 VA PVC shielded, standard length 5 m -25 C +60 C Simple (NO / NC depending on how you place the float) / Commutation / Resistive IP68 IP67 AISI 316 stainless steel AISI 316 stainless steel / NBR G 3/8 M G 1/2" M ATEX II 1G Ex ma IIC T6 Ga Ex ma CPTL07/P Miniature minimum level sensor. Main characteristics Max. switching voltage 28,8 VCA 28,8 VDC Max. switching current 0.5 A Max. switching power AC/DC 10 VA Cable type PVC shielded, standard length 3 m Operating temperature -25 C +60 C Output functions Simple (NO / NC depending on how you place the float) Protection degree IP68 Cable output IP67 Body material AISI 316 stainless steel Float material AISI 316 stainless steel Fixing G 1/8M Execution ATEX II 1G Ex ma IIC T6 Ga Installation and use Manual CPTML01 System PAGE 19

20 Gravity-activated leak sensor Ex ma AT38902/1-6/M This sensor allows the presence of liquid to be detected without being inserted into the tank. It operates according to the principle of communicating vessels. Main characteristics Max. switching voltage 28.8 VCA 28.8 VDC Max. switching current 0.5 A Max. switching power AC/DC 10 VA Cable type PVC shielded, standard length 3 m Operating temperature -25 C +60 C Output functions Switch / Switching Protection rating IP68 (Cable output IP67) Container material Brass Support material Galvanized steel Float material AISI 316 stainless steel Execution II 1G Ex ma IIC T6 Ga Optical sensor AT20901/i EEx ib Sensor for detecting the presence of a liquid within the wells, pipes or containment vessels. Main characteristics Voltage 10-18Vcc Consumption <50mA Output Open collector 40mA Operating temperature -20 C-+80 C Pressure 10 bar Material Polysulfone or nylon Execution Eex ib IIB T6 Vacuum switch for internal interstices AT01010/1/00 Trigger depression: calibration mbar AT01010/2/00 Trigger depressure: adjustable as requested -0,05-0,5 bar II 3 G/D S.A. Main characteristics Max load 1 A 24 VCC Max pressure 10 bar Operating temperature -25 C-+55 C Protection degree IP65 Seals Viton Contacts Gold Connection 1/4" BSP Body material Aluminum anodized Sensor without cable Installation and use Manual CPTML01 System PAGE 20

21 Pressure switch for external interstices AT01110/1/00 Trigger pressure: +150 mbar AT01110/2/00 Trigger pressure: adjustable as request +0,05 +0,5 bar II 3 G/D S.A. Main characteristics Max load 0,5 A 24 VCC Max pressure 10 bar Operating temperature -25 C-+55 C Preotection degree IP65 Seals Viton Contacts Gold Connection 1/4" BSP Body material Aluminum anodized Sensor without cable ACCESSORIES Remote alarm AT15507 The alarm can be activated by one of the control unit outputs. Xenon lamp AT17401/A This comprises a signaller with an amber xenon lamp (/A) frequency 1 Hz assembled on the roof of the container, protection rating IP67. Visibility on four sides. Two tone sirene AT08008 Two tone siren Light indicatore AT05909 Red/gresn light / green common anode 12VDC Installation and use Manual CPTML01 System PAGE 21

22 Serial connection kit AT13600/K Kit for connection the control unit to a remote computer for programming and downloading data Modem GSM/GPRS completo di antenna MHz con base magnetica Codice AT06706 Modem GSM/GPRS per la programmazione e la gestione dei dati a distanza. OPTIONS 8 IN control board AT01909 The board allows you to monitor additional 8 digital inputs associated to external events (Example: leak detectors, etc.). Protection circuit for Ex ma device AT17511/A Protection circuit for Ex ma devices but with the aim of limiting the voltage and current to the envisaged limits. Main characteristics Max input voltage 24 V ±5% Fuse 50 ma 250 V 35 A Installation and use Manual CPTML01 System PAGE 22

23 SPARE PARTS 1 SCHEDAC.P.U. DISPLAY TASTIERA AREA A SICUREZZA INTRINSECA 4 0 CN2 CN1 1 + A B - RX/TX DATA FLOW RS485 CLOSE LOOP CN2 SW1 COPTRON SOC.COOP. Via Industria, Morbegno (SO) Italy + B COM2 COM3 COM1 1 J4 J2 3 DEVICES STATUS A - CN3 SENSORI L In - SENSORE 1 SENSORE 4 SENSORE 6 CN5 CN7 Interruttore 6 SENSORE 2 SENSORE 5 SENSORE 7 ALIMENTATORE SENSORE 3 SENSORE 8 2 Cavo di alimentazione elettrico 230V AC CPTA03612 Rif. Codice Descrizione 1 AT24212 DISPLAY OPERATOR 2 AT V 25 W POWER SUPPLY 3 AT I/O CPU 4 AT01909 INPUTS I2C INTERFACE 5A CPT09012/IA INTRINSICALLY SAFE BARRIER FOR 8 I 4-20 ma Namur ON/OFF INPUTS 5B AT17511/A PROTECTION CIRCUIT FPR EX M SENSORS - AT19911 FUSE 500 MA V 250 V 1500 A 5X20 CERAMIC (PACK OF 10) 6 CA POWER SUPPLY CABLE - AT06706 GSM/GPRS MODULE COMPLETE OF MHZ ANTENNA WITH MAGNETIC BASE - AT MHZ ANTENNA WITH MAGNETIC BASE Installation and use Manual CPTML01 System PAGE 23

24 ACCESSORIES FOR THE SYSTEM Gravity-activated leak sensor AT38902/1/M 1 pipe AT38902/6/M 6 pipes Gravity-activated leak sensor to be installed on the bottom part of the sump so as to recover and signal any product leaks. Certifications II 1G Ex ma IIC T6 Ga EXPANSION unit 4 terminals AT21411/3 Expansion for leak sensor for a further 3 monitoring pipes. Flame trap for compensation pipe AT21511 Flame trap to be installed on the manifold vent pipe (if used). Certifications II 2G Ex d IIC Gb Stop valve AT02311 Stop valve to be used on pressurized circuits to prevent leaks of liquid. EXAMPLE OF APPLICATION FUEL DISPENSER BALANCE PIPE CONTROL UNIT CENTRALIZED LOAD FROM 1 TO 8 SENSORS BARREL FLAME TRAP AT21511 CPTA CAVITY SENSOR AT38901/6/M minimum slop of pipes 1% COMPENSATION PIPE EXPANSION MANIFOLD AT21411/4 Installation and use Manual CPTML01 System PAGE 24

25 Via Val D Aosta 169, Talamona (SO) Italy Tel Fax info@assytech.it Sito web: DICHIARAZIONE UE DI CONFORMITÀ PER PRODOTTI O SISTEMI DI PROTEZIONE ADATTI AD ESSERE UTILIZZATI IN ATMOSFERA ESPLOSIVA (ATEX 2014/34/UE) EU Declaration of Conformity of a product or protection system to be used in an explosive atmosphere (Atex 2014/34/EU) APPARECCHIATURA O SISTEMA DI PROTEZIONE : EQUIPMENT OR PROTECTIVE SYSTEM : CPTML01 serie AT39102/XIS - Sistema per il monitoraggio dei serbatoi CPTML01 series AT39102/XIS - Tank Monitoring System GRUPPO / GROUP : CATEGORIA / CATEGORY : II (1) G MARCATURA APPLICATA / APPLIED MARKING : II (1) G [Ex ia] IIC T4 E COSTRUITA IN ACCORDO CON LE SEGUENTI NORME : IS MANUFACTURED ACCORDING THE FOLLOWING STANDARDS : EN :2004 EN :2007 EN :2003 EN : A1 + A2 + A3 EN :2001 CON LA PRESENTE SI DICHIARA CHE L APPARECCHIATURA SOPRA CITATA SODDISFA I REQUISITI ESSENZIALI DI SICUREZZA DELLE SEGUENTI DIRETTIVE UE : WE HEREBY DECLARE THAT THE ABOVE MENTIONED EQUIPMENT COMPLIES WITH THE ESSENTIAL SAFETY REQUIREMENTS OF THE FOLLOWING EU DIRECTIVES : 2014/34/UE (ATEX) 2014/30/UE (EMC) 2014/35/UE (LVD) IL LEGALE RAPPRESENTANTE THE LEGAL REPRESENTATIVE Talamona, 30/06/2016

26

27 Via Val D Aosta 169, Talamona (SO) Italy Tel Fax info@assytech.it Sito web: DICHIARAZIONE UE DI CONFORMITÀ EU DECLARATION OF CONFORMITY APPARECCHIATURA : EQUIPMENT : CPTML01 serie AT39102/XIM - Sistema per il monitoraggio dei serbatoi CPTML01 series AT39102/XIM - Tank Monitoring System E COSTRUITA IN ACCORDO CON LE SEGUENTI NORME : IS MANUFACTURED ACCORDING THE FOLLOWING STANDARDS : EN : A1 + A2 + A3 EN :2001 CON LA PRESENTE SI DICHIARA CHE L APPARECCHIATURA SOPRA CITATA SODDISFA I REQUISITI ESSENZIALI DI SICUREZZA DELLE SEGUENTI DIRETTIVE UE : WE HEREBY DECLARE THAT THE ABOVE MENTIONED EQUIPMENT COMPLIES WITH THE ESSENTIAL SAFETY REQUIREMENTS OF THE FOLLOWING EU DIRECTIVES : 2014/30/UE (EMC) 2014/35/UE (LVD) IL LEGALE RAPPRESENTANTE THE LEGAL REPRESENTATIVE Talamona, 30/06/2016

28

29 Via Val D Aosta 169, Talamona (SO) Italy Tel Fax info@assytech.it Sito web: DICHIARAZIONE UE DI CONFORMITÀ EU DECLARATION OF CONFORMITY APPARECCHIATURA : EQUIPMENT : CPTML01 serie AT39102/XIA Sistema per il monitoraggio dei dei serbatoi CPTML01 series AT39102/XIA Tank Monitoring System E COSTRUITA IN ACCORDO CON LE SEGUENTI NORME : IS MANUFACTURED ACCORDING THE FOLLOWING STANDARDS : EN : A1 + A2 + A3 EN :2001 CON LA PRESENTE SI DICHIARA CHE L APPARECCHIATURA SOPRA CITATA SODDISFA I REQUISITI ESSENZIALI DI SICUREZZA DELLE SEGUENTI DIRETTIVE UE : WE HEREBY DECLARE THAT THE ABOVE MENTIONED EQUIPMENT COMPLIES WITH THE ESSENTIAL SAFETY REQUIREMENTS OF THE FOLLOWING EU DIRECTIVES : 2014/30/UE (EMC) 2014/35/UE (LVD) IL LEGALE RAPPRESENTANTE THE LEGAL REPRESENTATIVE Talamona, 30/06/2016

30

31 DICHIARAZIONE DI CONFORMITÁ UE EU DECLARATION OF CONFORMITY Noi We COPTRON Soc. Coop. Via Industria, Morbegno (SO) - Italy dichiariamo sotto la nostra esclusiva responsabilità che il prodotto: declare under our sole responsibility that the product: Interruttore di livello tipo: Level switch type: CPTL07 al quale questa dichiarazione si riferisce, è conforme alle seguenti Direttive ed emendamenti successivi: Direttiva ATEX 2014/34/UE Direttiva EMC 2014/30/UE Direttiva Bassa Tensione 2014/35/UE to which this declaration relates, complies with the following Directives and further amendments: ATEX Directive 2014/34/EU EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU La conformità è stata dimostrata sulla base dei requisiti delle norme o dei documenti normativi riportati qui di seguito: EN EN EN EN EN Modo di protezione / Type of protection: ATEX II 1G Ex ma IIC T6 Ga Temperatura ambiente / Ambient temperature: -25 / +60 C Certificato UE di Tipo / EU type approval certificate: IMQ 08 ATEX 017 X Organismo notificato ATEX / ATEX notified body: 0051 The conformity has been demonstrated with reference to the following standards and normative documents: Istruzioni per la sicurezza nell impiego Vedi capitolo Istruzioni per la sicurezza nell impiego riportato nel manuale tecnico. Instruction for a safe use See the Instruction for a safe use as indicated inside the technical manual. Luogo e data di emissione : Place and date of issue: In nome e per conto di Coptron Soc. Coop. For and on behalf of Coptron Soc. Coop. Morbegno (Italy), 12/07/2016 Edoardo Motti

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series Pag. 1/6 Enclosure for asynchronous electric motors Series LEX 80,90,100,112,132,160,180,200,225,250,280,315 and 355 Ex na, Ex td execution II 3G, II 2D SAFETY INSTRUCTIONS euromotori motori elettrici

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH Page /3 SPECIFICATION SHEET Ed. Document UTE_ Issued Written Verified Approved MP36350 6-05-05 Strizzi Franco Page /3 INDICE HISTORY... 3 MODIFY RECORDING... 3 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

More information

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...

More information

SET-2000 Hi Level/Oil

SET-2000 Hi Level/Oil Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March

More information

SET-2000 Oil/Sludge 12 VDC

SET-2000 Oil/Sludge 12 VDC Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 12.2.2015 Internet: www.labkotec.fi 1/14 SET-2000 Oil/Sludge 12 VDC Alarm Device for Oil Separators with

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

OilSET-1000 (12 VDC)

OilSET-1000 (12 VDC) Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Main features Event recording up to 32 Gb removable microsd card (only

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

Solar Separator Alarm Type Installation, Operation & Maintenance

Solar Separator Alarm Type Installation, Operation & Maintenance Solar Separator Alarm Type 14007 Installation, Operation & Maintenance Solar Separator Alarm Type 14007 Contents Declaration of Conformity 3 Important 3 General Description 3 General Operation 3 Changing

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width) SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance Battery Powered Separator Alarm Type 17200 Standalone Unit Installation, Operation & Maintenance Battery Powered Separator Alarm Type 17200 Contents Declaration of Conformity 3 IMPORTANT 3 General Description

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Instrumentation Products and Applications

Instrumentation Products and Applications 1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. CONTROL PANEL... 9 5.1

More information

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0) Level alarm for oil separator CONTENTS: Functional description... 2 Component parts... 3 Spare parts... 5 Safety regulations... 6 Checklist... 7 Installation... 8 Commissioning... 11 Operation... 14 Maintenance...

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL Contents IMPORTANT... 3 General Description... 4 General Operation... 4 Changing Factory Settings... 4 Alarm Type... 4 Check Interval...

More information

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art USER S MANUAL Rectifier 1 10 A/10 48 V for Kliar Line Art. 3004052 Dichiarazione CE di Conformità CE Conformity Declaration TIPO DELLA MACCHINA: RADDRIZZATORE 1 PRODUCT TYPE: RECTIFIER 1 Modello/ Model

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual.

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual. The device described in this manual has been manufactured in accordance with safety standards and conforms to the stipulations of current standards in force. When correctly assembled, installed and used

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

LevelSET S GSM Functionalities Instructions for Commissioning and Use

LevelSET S GSM Functionalities Instructions for Commissioning and Use Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala, Finland Tel: +358 29 006 260 Fax: +358 29 006 1260 22.10.2010 Internet: www.labkotec.fi LevelSET S GSM Functionalities Instructions for Commissioning and Use

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard. COMMUNICATOR ET08 User Manual v1.0 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator (gateway) ET08 (further

More information

Operating Instructions Edition 02/2007

Operating Instructions Edition 02/2007 Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Manual Isolating Barrier D461R1 (Revision 01)

Manual Isolating Barrier D461R1 (Revision 01) D461R1 Manual Isolating Barrier D461R1 (Revision 01) Product Manual Original Instructions valid for models D461R1.11 with 1x signal input into 1x isolated signal output D461R1.12 with 1x signal input into

More information

COMMUNICATOR ET08 / ET081

COMMUNICATOR ET08 / ET081 COMMUNICATOR ET08 / ET081 User Manual v1.2 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator ET08 / ET081 (further

More information

Intrinsically Safe Solutions

Intrinsically Safe Solutions Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited Telephone: 44 (0)1423 580500 Facsimile: 44 (0)1423 580501 DA135 Intrinsically Safe LED Beacon Introduction This manual provides the information necessary

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

DB5 Intrinsically Safe Sounder Type DB-5

DB5 Intrinsically Safe Sounder Type DB-5 Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4

More information

SOLAR SEPARATOR ALARM

SOLAR SEPARATOR ALARM SOLAR SEPARATOR ALARM INSTALLATION AND OPERATIONS MANUAL Great British Manufacturing For emergency supply, spill cleanup, disposal, contracting, advice and training. Subject Contents Page Important 3 General

More information

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality

More information

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm External Dimensions: B = 600 mm D = 630 mm H = 2000 mm Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm Capacity: 328 l Temperaturerange: -15 C to -30 C Housing galvanized sheet steel with white

More information

Fisher LCP100 Local Control Panel

Fisher LCP100 Local Control Panel Instruction Manual LCP100 Local Control Panel Fisher LCP100 Local Control Panel Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Hazardous Area Classifications

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

Operating Instructions

Operating Instructions Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc

More information

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

EasyTech.One Temperature Controller for Pellet Burner

EasyTech.One Temperature Controller for Pellet Burner EasyTech.One Temperature Controller for Pellet Burner Burner 1 INTRODUCTION... 3 2 ELECTRICAL CONNECTIONS... 3 3 CONTROL PANEL: USE AND FUNCTIONS... 5 3.1 LED... 5 3.2 BUTTONS... 5 3.3 ALARMS... 5 3.1

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

HUMIDITY AND TEMPERATURE CONTROLLER

HUMIDITY AND TEMPERATURE CONTROLLER HUMIDITY AND TEMPERATURE CONTROLLER HT INSTALLATION, MAINTENANCE AND USER MANUAL Elsteam S.r.l.. Ver. 14.01.UK ToC 1. PACKAGE CONTENT... 3 2. SECURITY MEASURES... 3 1.1 GENERAL MEASURES... 3 1.2 THERMO-HYGROMETRIC

More information

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3 2402 COMBUSTIBLE GAS CARD 2 CHANNELS 2404 TOXIC GAS CARD 2 CHANNELS 2407 OXYGEN GAS CARD 2 CHANNELS INSTRUCTION MANUAL Software Revision Card 3.2 DOCUMENT SES-KS-2402-04-07-E REV. 3 2402 2404 2407-2 CHANNELS

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card

More information

USER MANUAL Mobeye ThermoGuard CM2200

USER MANUAL Mobeye ThermoGuard CM2200 USER MANUAL Mobeye ThermoGuard CM2200 SW version 1.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

Universal Tank Alarm Type Installation, Operation & Maintenance

Universal Tank Alarm Type Installation, Operation & Maintenance Universal Tank Alarm Type 14400 Installation, Operation & Maintenance Universal Tank Alarm Type 14400 Contents Declaration of Conformity 3 IMPORTANT 3 General Description 4 General Operation 4 Installation

More information

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller DCS-130 User Manual Ver 1.20 Date Issued: 14-9-2010

More information

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe

More information

S/601 Controller Installation Manual

S/601 Controller Installation Manual Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control

More information

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND MAINTENANCE INSTRUCTIONS 2251EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector A Division of Pittway 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2,

More information

Tank Gauging System Special Safety Instruction

Tank Gauging System Special Safety Instruction Tank Gauging System www.rosemount-tg.com Rosemount TankRadar REX Table of Contents Contents SPECIAL SAFETY INSTRUCTION........................ 1-1 1. GENERAL REQUIREMENTS....................... 1-2 1.1

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

14300 MAINS SEPARATOR ALARM MANUAL

14300 MAINS SEPARATOR ALARM MANUAL Conder Environmental Solutions 14300 MAINS SEPARATOR ALARM MANUAL Separator and Alarm provided by: Alarm Installation, Commissioning & Servicing Support Please contact: www.envirotank.com.au www.envirotank.co.nz

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

Colibri. Automatic Tank Gauge CL6 Series Installation Guide Colibri Automatic Tank Gauge CL6 Series Installation Guide Manual # Revision Date Changes from Previous Revision 000-2153 C Jan. 2013 Pipe compound brand change, Updated Control drawing. Franklin Fueling

More information

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

HELPY CONTROLLER QUICK GUIDE

HELPY CONTROLLER QUICK GUIDE Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY CONTROLLER QUICK GUIDE 05/04/2019 DESCRIPTION Autodialer specifically designed for installation on elevator controller.

More information

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics... 14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...

More information

1. User features of the GSM dialer

1. User features of the GSM dialer 1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required. TTSIM-1A TraceTek Sensor Interface Module with Relay Installation Items (not supplied) General Information Installation/Operation Instructions Please read these instructions and keep them in a safe place.

More information

Installationsmanual GWSL1100/2100, GWML3100

Installationsmanual GWSL1100/2100, GWML3100 GRAIN-WATCH SYSTEM Installationsmanual Grain Watch Sensor Cables GWSL1100/2100, GWML3100 Table of contents 1 1 1 3. Safety certification and features 3.1. Certification label information 3.2. Safety approvals

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0 IRIS Touch 400 & 600 Range Installation Manual Honeywell Galaxy Range Version 2.0 Table of Contents 1 System Overview... 4 2 IRIS Touch 440 & 640 PCB Layout... 5 3 Connection & Configuration for Honeywell

More information