Design and Remediation for Fire Safety of Ready-Made Garment Factories in Bangladesh. Felipe Herrera Arup Fire

Size: px
Start display at page:

Download "Design and Remediation for Fire Safety of Ready-Made Garment Factories in Bangladesh. Felipe Herrera Arup Fire"

Transcription

1

2 Design and Remediation for Fire Safety of Ready-Made Garment Factories in Bangladesh Felipe Herrera Arup Fire

3 Outline Introduction Background Project 1: Getting to know Bangladesh Project 2: Training fire-fighters Project 3: Analysing factories for fire safety Project 4: Ongoing training project Conclusions

4 Background Proliferation of RMG industrial buildings in Bangladesh RMG accounts for 80% of national exports Weaknesses in planning design and construction No clear authorities responsible of enforcing laws Rana Plaza structural collapse and Tazreen fire among others Collective action from national and international initiatives

5 Background Weaknesses in planning design and construction. Rana Plaza structural collapse

6 Background Fire incidents Shoe Factory, Manila Philippines May 2015 (72 deaths) Garment Factory, Dhaka Bangladesh, Nov (117 deaths) Tazreen fire

7 Background Who is responsable for fire safety design in the building process? Fire Services 16 out of 25 junior engineers reacted Rajuk 9 out of 25 Desco 5 out of 25 Building Approval Authority 1 out of 25 Public Works Department 4 out of 25 Architect or S.M.E.P engineers 2 out of 25 Others 3 out of 25

8 Project 1 Getting to Know Bangladesh 1 st visit to Bangladesh Fire safety training for surveyors Guidance for survey report production Data gathering and factory safety report analysis

9 Project 1 Findings Fire safety in Bangladesh is linked to a sociological complexity Solutions linked to: culture, RMG industry, idiosincracy of people, economy, design processes, approvals Fundamental flaws Industry wide solutions Global influences are clearly present Role of fire practitioner is complex everywhere

10 Project 1 Getting to Know Bangladesh

11 Collective Action National Tripartite Government (ILO), Factory employers + Accord + Alliance Phase 1 Inspections Phase 2 Detailed assessments Phase 3 Remedial Works Phase 4 Sustained local process

12 Project 2 Training Fire-Fighters (FSCD) Understanding of the basic design principles behind fire safety engineering practice as envisaged by (BNBC 2006). Assess fire safety issues on garment factories and understand remedial actions being proposed by reports Understanding of the design principles behind the requirements for means of escape Understanding of what an Emergency Action Plan (EAP) should consist of and how responsibilities should be assigned.

13 Project 2 Training Fire-Fighters (FSCD)

14 Project 2 Findings Fire safety principles shall be taught and learned within a longer educational process Some fundamental safety issues were completely foreign and design techniques have developed through the years with a gap in these fundamental topics. E.g. no-protection of stairs in multi-story buildings A few years will be needed for knowledge to permeate down

15 Project 2 Training Fire-Fighters (FSCD)

16 Project 2 Training Fire-Fighters (FSCD)

17 Project 3 Analysing Factories for Fire Safety In 2.5 years ILO surveyed 1350 factories (40%) Remediation of factories outside of Accord + Alliance initiative Capacity building of state and industry entities Fire safety approvals entities Ensure step change forward in industry Accord Alliance ILO/Government 1350 (40%)

18 Project 3 Analysing Factories for Fire Safety Provide international educational support (not only fire!) Sharing fire engineering and safety knowledge Training and technical guidance given throughout the surveying process A long-run process to assess, guide, improve and refurbish factories for clear set out safety improvements The benchmark was agreed and developed by many stakeholders under a governmental framework and initiative

19 Project 3 Analysing Factories for Fire Safety

20 Project 3 Analysing Factories for Fire Safety Priority fire safety measures 1. Effective fire detection systems 2. Automatic fire alarm systems 3. Protected escape routes 4. Fire separation of areas with unusually high fire loads Typical most critical defficiencies Endemic, no matter age or location of the building

21 Project 3 Findings risk factors to have a reference or rule of thumb framework of when a factory could have a higher or lower qualitative fire risk 1. High rise buildings 2. Multi-tenancy buildings 3. Having a ground floor with mixed uses 4. Having a basement 5. Having a mezzanine

22 Project 3 Findings Based on this approach: 31% were considered high risk ; with 12% of these having 3 or more risk factors present; 39% present one risk factor; 30% present no risk factors therefore can be considered lower risk in terms of fire safety and safe evacuation. Even with zero risk factors the factories could still display many fire safety deficiencies.

23 Project 4 Means of Evacuation

24 Project 4 Protection of Stairs

25 Project 4 Ongoing Training Project Build capacity and skills that engineers will require in the future Develop knowledge in fire, electrical and structural engineering Building design in a regulatory context: Technical surveys Design of new buildings Retro-fitting and remedial works Building Codes and Standards Regulatory framework and procedures

26 Conclusions Work in Bangladesh started as a conventional project Addressing the issues turned out to be a mission A tragedy can give rise to change

27 Conclusions Technical knowledge Technically skilled people (From Intl. sources?) Fire safety is more than design Vigilance at all levels training, design, approvals, implementation & maintenance Regulatory framework Responsibilities and accountability to be understood Fire risks and costs For financial benifit analyses, too Resilience and safety risks Fire risks may be undermined

28 Conclusions Is SFPE having a direct impact on the entire range of countries, from the highest developed ones to the lowest developed ones? Are fire engineered solutions or performance-based approaches practical or relevant in middle income and low income countries that are lacking fundamental fire safety practices? Would international standards such as ISO standards be helpful, if developed towards an international market of developing countries in parallel to their local building codes?

Prospects and Opportunities for the Dutch Fire Safety Sector in Bangladesh

Prospects and Opportunities for the Dutch Fire Safety Sector in Bangladesh Prospects and Opportunities for the Dutch Fire Safety Sector in Bangladesh Report written by Mott MacDonald on behalf of The Netherlands Embassy in Dhaka, Bangladesh and Netherlands Enterprise Agency (RVO.nl).

More information

INITIAL FIRE ASSESSMENT REPORT (FAR)

INITIAL FIRE ASSESSMENT REPORT (FAR) INITIAL FIRE ASSESSMENT REPORT (FAR) Factory 94/95 (OLD) 46 NEW (Ground To 5th), BLOCK C TONGI INDUSTRIAL AREA,, TONGI, GAZIPUR, GAZIPUR, 0, BD GAZIPUR Dhaka Bangladesh 11 Apr 2014 The Alliance for Bangladesh

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Name: 2 New Eskaton Road, Mogbazar, Dhaka Dhaka Dhaka Bangladesh 15 Jun 2013 The Alliance for Bangladesh Worker Safety Page 1/10 Factory Name: 15 Jun 2013

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Address: Plot # 59-87, Adamjee Export Processing ZONE, Adamjee Nagar, Siddergonj, Narayangonj, Siddirgonj, Narayangonj Dhaka Bangladesh 09 Jun 2014 The

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot No -246-249, Adamjee EPZ, Siddhirganj, Narayanganj Narayanganj 17 Jul 2016 The Alliance for Bangladesh Worker Safety Page 1/17 Factory 17 Jul 2016 Introduction

More information

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P-02-07 THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS March, 2007 Society of Fire Protection Engineers - 1 - Position

More information

INITIAL FIRE ASSESSMENT REPORT (FAR)

INITIAL FIRE ASSESSMENT REPORT (FAR) INITIAL FIRE ASSESSMENT REPORT (FAR) Factory SQ Station, Plot # 221-223, Jamirdia, Valuka, Mymensingh Mymensingh 17 Jun 2014 The Alliance for Bangladesh Worker Safety Page 1/17 Factory 17 Jun 2014 Introduction

More information

Developing Legislative Principles for e-waste policy in developing and emerging countries

Developing Legislative Principles for e-waste policy in developing and emerging countries Developing Legislative Principles for e-waste policy in developing and emerging countries Jonathan Perry (Dell) & Eelco Smit (Philips) Leads of Step Working Group Why a White Paper on Legislative Principles

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Assessor: N. Islam Center, Mazar Road, Dhakkhin Khan Uttara, Dhaka Dhaka Emkay Enterprises The Alliance for Bangladesh Worker Safety Page 1/10 09 Jun 2014 Introduction to

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Assessor: Plot no. A102, BSCIC Industrial Estate, Tongi, Gazipur Tongi, Gazipur Emkay Enterprises 06 Jul 2014 The Alliance for Bangladesh Worker Safety Page 1/22

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Address: Plot 1175 & 1179, Bashan Sarak, Vogra, PO. National University, Gazipur Sadar, Gazipur Gazipur Dhaka Bangladesh 15 Jun 2016 The Alliance for Bangladesh Worker

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Nishchintapur, Ashulia DEPZ road, Zirabo, Savar Savar Dhaka 08 May 2014 The Alliance for Worker Safety Page 1/8 08 May 2014 Introduction to the Report The following

More information

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) Assessor: N. Islam Center, Mazar Road, Dhakkhin Khan Uttara, Dhaka Dhaka Emkay Enterprises The Alliance for Bangladesh Worker Safety Page 1/6 Introduction to

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Mouza Chandra, Shafipur, Kaliakoir, Gazipur Gazipur Dhaka 24 Mar 2014 The Alliance for Worker Safety Page 1/12 24 Mar 2014 Introduction to the Report The following

More information

Bangladesh Ready-Made Garment Industry High-Level Assessment Report

Bangladesh Ready-Made Garment Industry High-Level Assessment Report Bangladesh Ready-Made Garment Industry High-Level Assessment Report FINAL REPORT PREPARED BY: National Fire Protection Association Quincy, Massachusetts USA FOR: The Alliance for Bangladesh Worker Safety

More information

BEST VALUE PERFORMANCE INDICATORS CONSULTATION: INSURERS VIEWS ON ITS IMPLICATIONS A RESPONSE BY THE ASSOCIATION OF BRITISH INSURERS

BEST VALUE PERFORMANCE INDICATORS CONSULTATION: INSURERS VIEWS ON ITS IMPLICATIONS A RESPONSE BY THE ASSOCIATION OF BRITISH INSURERS BEST VALUE PERFORMANCE INDICATORS CONSULTATION: INSURERS VIEWS ON ITS IMPLICATIONS A RESPONSE BY THE ASSOCIATION OF BRITISH INSURERS The Association of British Insurers (ABI) is the trade association for

More information

CONSERVATION PLAN BASED ON THE CONCEPT OF INTEGRITY

CONSERVATION PLAN BASED ON THE CONCEPT OF INTEGRITY CONSERVATION PLAN BASED ON THE CONCEPT OF INTEGRITY Y. N. Yen a C. F. Cheng a, * a China University of Technology, 56 Sec. 3 Shin Long Rd., 116 Taipei, Taiwan - (alexyen, aabbyy)@ cute.edu.tw KEY WORDS:

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Dhanpur, Chapapur, Kotwali, Comilla COMILLA Chittagong The Alliance for Worker Safety Page 1/16 Introduction to the Report The following report contains a site profile and

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT GLOBAL OUTWEAR LTD. PLOT # M/1, ROAD # 7, SECTION # 7, MIRPUR, DHAKA March 3, 2014 Accord - Bangladesh RMG Fire Safety Inspection Global Outwear Ltd. Page 2 SUMMARY Global

More information

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment WALMART SUPPLIER FACTORY SAFETY ASSESSMENT OVERVIEW Wal-Mart Stores, Inc. ( Walmart ) engaged Bureau Veritas to conduct fire, building and electrical safety assessments at factories in Bangladesh designated

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Hatimara Road, Barenda, Kashimpur, Gazipur, Gazipur Dhaka The Alliance for Worker Safety Page 1/11 30 Oct 2016 Introduction to the Report The following report

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION 228/1, Tin Sharak, Luxmipura, Joydevpur, Gazipur Joydebpur, Gazipur The Alliance for Bangladesh Worker Safety Page 1/18 Introduction to the Report The following

More information

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) Factory Name: AJ Super Garments Ltd (Woven) Aj Garden, Goshbagh Zirabo Zirabo, Savar Savar Dhaka Bangladesh 23 Mar 2014 The Alliance for Bangladesh Worker Safety

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Assessor: 28 S.S. Tower, Vogra, Joydebpur, Gazipur Joydebpur, Gazipur Dhaka Uttaron The Alliance for Worker Safety Page 1/17 12 Apr 2015 Introduction to the Report The following

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory 214 Baiozid Bostami Road Nasirabad Industrial Area Chittagong 04 Sep 2016 The Alliance for Bangladesh Worker Safety Page 1/11 Factory 04 Sep 2016 Introduction to

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Assessor: Konabari, Neelnagar, Gazipur Gazipur Dhaka Bangladesh Uttaron The Alliance for Bangladesh Worker Safety Page 1/13 Introduction to the Report The following

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Name: Assessor: Anzir Apparels Limited, Unit-1 Karim supermarket, Baipal, Baipal, Savar Savar Dhaka Bangladesh Emkay Enterprises 30 Apr 2014 The Alliance for Bangladesh

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Nayabari, Kanchpur, Sonargaon, Narayanganj. Sonargaon Dhaka 14 Nov 2013 The Alliance for Worker Safety Page 1/15 Factory 14 Nov 2013 Introduction to the

More information

Improving the Quality of Life in Urban Regions Through Urban Greening Initiatives EU URGE-Project

Improving the Quality of Life in Urban Regions Through Urban Greening Initiatives EU URGE-Project 00016 Improving the Quality of Life in Urban Regions Through Urban Greening Initiatives EU URGE-Project Richard Coles 1 and Nick Grayson 2 1 Faculty of the Built Environment, University of Central England,

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Vill: Golora, Post: Kaitta P.S. Saturia, Manikgonj Manikgonj, Dhaka The Alliance for Bangladesh Worker Safety Page 1/14 Introduction to the Report The following

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Name: Maks Fashion Ltd 1 Kapashgola Road Chawkbazar Chittagong Chittagong Bangladesh 19 Apr 2014 The Alliance for Bangladesh Worker Safety Page 1/16 19 Apr 2014 Introduction

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot No. 74, Block -K, Rupnagar Ind. Area, Secti, Dhaka Dhaka Dhaka The Alliance for Worker Safety Page 1/8 Introduction to the Report The following report

More information

Analysis of Availability of Fire Fighting Equipment in Selected Knitting Garment Factories in Bangladesh

Analysis of Availability of Fire Fighting Equipment in Selected Knitting Garment Factories in Bangladesh Proceedings of the 215 International Conference on Operations Excellence and Service Engineering Orlando, Florida, USA, September 1-11, 215 Analysis of Availability of Fire Fighting Equipment in Selected

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Assessor: 180, Baizid Bostami Road Nasirabad I/A Area-1, Building -1, Chittagong Chittagong Chittagong Bangladesh Emkay Enterprises 31 Jan 2015 The Alliance for Bangladesh

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT B.K. Bari, Taltoli, Mirzapur Bazar, Gazipur Sadar Gazipur Gazipur Dhaka The Alliance for Worker Safety Page 1/11 Introduction to the Report The following report

More information

c. DTAH Toronto Complete Streets Guidelines

c. DTAH Toronto Complete Streets Guidelines c. DTAH Toronto Complete Streets Guidelines 164 166 C.1 Project Delivery Process 168 C.5 This section provides a summary of the overarching process for delivering street projects in Toronto. The conclusion

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Name: 4 YOU CLOTHING LTD 367/1 Senpara Parbata, Mirpur-10, Dhaka Dhaka Dhaka Bangladesh 27 May 2014 The Alliance for Bangladesh Worker Safety Page 1/20

More information

BANGLADESH FIRE SAFETY ACTION STEPS

BANGLADESH FIRE SAFETY ACTION STEPS BANGLADESH FIRE SAFETY ACTION STEPS MICRO AND MACRO LEVEL INITIATIVES SAIF KHAN April 26, 2013 Factory Level Initiatives Industry Level Initiatives What s already there Any New Initiative How To Do It

More information

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment WALMART SUPPLIER FACTORY SAFETY ASSESSMENT OVERVIEW Wal-Mart Stores, Inc. ( Walmart ) engaged Bureau Veritas to conduct fire, building and electrical safety assessments at factories in Bangladesh designated

More information

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) Assessor: Karardi, Shibpur, Narsingdi Narsingdi Dhaka Bangladesh Emkay Enterprises The Alliance for Bangladesh Worker Safety Page 1/15 10 Apr 2016 Introduction

More information

Firefighting operations on construction sites F5-12 GD

Firefighting operations on construction sites F5-12 GD DESIGNER S GUIDE Firefighting operations on construction sites F5-12 GD Introduction When to use Scope The purpose of this chapter is to provide a consistent Fire and Emergency New Zealand position on

More information

Cannards Grave Road Shepton Mallet Design Workshop 1 st June2016

Cannards Grave Road Shepton Mallet Design Workshop 1 st June2016 Cannards Grave Road Shepton Mallet Design Workshop 1 st June2016 Overview Start of a process: Looking at the land south of the town, to the west of Cannards Grave Road as identified in the Local Plan.

More information

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Guide to Compliance with the Electrical Workplace Safety Standards in the United States Guide to Compliance with the Electrical Workplace Safety Standards in the United States July 2011/1910DB1102 by Joseph H. Weigel, Product Manager Schneider Electric USA, Inc. Make the most of your energy

More information

Management Standard: Fire Safety

Management Standard: Fire Safety OHSS: H&S Management 201 Fire Safety Management : Fire Safety 1. Legal framework This standard is produced to comply with the following legislation in respect to fire safety: 1.1. Regulatory Reform (Fire

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT ABA FASHIONS LTD. SENA KALYAN COMMERCIAL COMPLEX (2ND FLOOR), PLOT # 9, BLOCK # F, TONGI, GAZIPUR March 16, 2014 Accord - Bangladesh RMG Fire Safety Inspection ABA Fashions

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Factory Mogorkhal, Chowrasta, National University, Gazipur Gazipur Dhaka 09 May 2016 The Alliance for Worker Safety Page 1/13 09 May 2016 Introduction to the

More information

Fire Safety briefing. August Executive summary. A chronic issue. Recent industrial fires. Responsible sourcing insights briefing

Fire Safety briefing. August Executive summary. A chronic issue. Recent industrial fires. Responsible sourcing insights briefing Fire Safety briefing August 2013 Executive summary This briefing identifies fire safety challenges and opportunities to reduce or eliminate the risks to workers of workplace fires. In this briefing: Insights

More information

INITIAL ELECTRICAL SAFETY ASSESSMENT - EXPANSION

INITIAL ELECTRICAL SAFETY ASSESSMENT - EXPANSION INITIAL ELECTRICAL SAFETY ASSESSMENT - EXPANSION Assessor: Nalzani, Chandana Joydebpur, Gazipur Joydebpur, Gazipur Dhaka Emkay Enterprises The Alliance for Worker Safety Page 1/13 Introduction to the Report

More information

The Question. Building Regulations Sympathetic Interventions in the Care of Heritage Buildings Toby McCorry CEng, Beng, FDSc, MIFireE

The Question. Building Regulations Sympathetic Interventions in the Care of Heritage Buildings Toby McCorry CEng, Beng, FDSc, MIFireE Building Sympathetic Interventions in the Care of Heritage Toby McCorry CEng, Beng, FDSc, MIFireE The Question Can a resolution be sought that marries a sympathetic and sensitive intervention philosophy

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Anowara, Plot # G1 and G2, Korean EPZ, Chittagong Chittagong 21 May 2015 The Alliance for Bangladesh Worker Safety Page 1/22 21 May 2015 Introduction to the Report

More information

Cities and urbanisation

Cities and urbanisation www.pwc.com/urbanisation Cities and urbanisation Unlocking the power of cities for sustainable development New York Beijin Shanghai London Tokyo Mexico City Sydney Sao Paulo Istanbul Singapore Paris Toronto

More information

Cities and urbanisation

Cities and urbanisation www.pwc.com/urbanisation Cities and urbanisation Unlocking the power of cities for sustainable development City growth challenges Rapid urbanisation can be a positive indicator of growth, but this comes

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Bashtoli, Sinabah, Sofipur, Kaliakoir, Gazipur Gazipur Dhaka 08 Sep 2014 The Alliance for Worker Safety Page 1/10 Factory 08 Sep 2014 Introduction to the Report The

More information

International Summer School. African Heritage and the Pillars of Sustainability. Call for Papers

International Summer School. African Heritage and the Pillars of Sustainability. Call for Papers International Summer School African Heritage and the Pillars of Sustainability Call for Papers African Heritage and the Pillars of Sustainability Call for Papers 2016 International Summer School Iringa,

More information

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT Factory Assessor: Thakurbari TEAC, Masumabad, Bhulta, Rupganj, Narayangonj Rupgonj Uttaron 18 Nov 2013 The Alliance for Bangladesh Worker Safety Page 1/12

More information

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT Factory Kunia, K.B.Bazar, Joy Bangla Road, Barabari, Gazipur Gazipur Dhaka 12 May 2014 The Alliance for Worker Safety Page 1/14 Factory 12 May 2014 Introduction

More information

Consolidated Workshop Proceedings Report

Consolidated Workshop Proceedings Report Consolidated Workshop Proceedings Report Regional Workshop on Urban Risk Damascus, Syria, November 4. 5. 2009 UNISDR, the Global Facility for Disaster and Recovery (GFDRR) of the World Bank, UNDP Syria

More information

UNEP s Role in Promoting Environmentally Sound Management of E-Waste

UNEP s Role in Promoting Environmentally Sound Management of E-Waste UNEP s Role in Promoting Environmentally Sound Management of E-Waste 2 nd E-Waste Management Forum Green Business Opportunities 23 rd 24 th November 2010 Marrakech, Morocco By: Fareed I. Bushehri 11/24/2010

More information

Practice Advisory 18: Fire safety design for tall buildings

Practice Advisory 18: Fire safety design for tall buildings Practice Advisory 18: Fire safety design for tall buildings It s important that reliable and resilient fire design features are used in the design of tall buildings. This advisory highlights the specific

More information

AFRISAM-SAIA AWARD 4 SUSTAINABLE ARCHITEC TURE + INNOVATION

AFRISAM-SAIA AWARD 4 SUSTAINABLE ARCHITEC TURE + INNOVATION AFRISAM-SAIA AWARD 4 SUSTAINABLE ARCHITEC TURE + INNOVATION SHAPING OUR COMMUNITIES FOR LIVABLE SUSTAINABILITY We call on all practitioners who share our vision to enter the AfriSam-SAIA Award for Sustainable

More information

Consolidated Workshop Proceedings Report

Consolidated Workshop Proceedings Report United Nations International Strategy for Disaster Reduction Regional Office for Arab States THE WORLD BANK Syrian Ministry of Local Administration Consolidated Workshop Proceedings Report Regional Workshop

More information

PREVENTION, PROTECTION, ROAD SAFETY

PREVENTION, PROTECTION, ROAD SAFETY Learning and Development Managers Conference, 26 th April 2013 Firefighting in, and Protecting, the Built Environment Peter O Reilly Director of Prevention and Protection Greater Manchester Fire and Rescue

More information

This is a repository copy of Fire Safety in the Readymade Garment Sector in Bangladesh: Structural Inadequacy vs. Management Deficiency.

This is a repository copy of Fire Safety in the Readymade Garment Sector in Bangladesh: Structural Inadequacy vs. Management Deficiency. This is a repository copy of Fire Safety in the Readymade Garment Sector in Bangladesh: Structural Inadequacy vs. Management Deficiency. White Rose Research Online URL for this paper: http://eprints.whiterose.ac.uk/98998/

More information

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report 42 Haslucks Croft, Shirley, Solihull, B90 2EQ (t) 0121 249 1281 (m) 07814 203 977 www.veritas-consulting.co.uk The Regulatory Reform (Fire Safety) Order 2005 Fire Risk Assessment Report Client The Company

More information

The UK National Radon Action Plan From Directive to Publication

The UK National Radon Action Plan From Directive to Publication The UK National Radon Action Plan From Directive to Publication Neil McColl, Jane Bradley, Tracy Gooding PHE Centre for Radiation, Chemical and Environmental Hazards Radon in the UK Radon in the UK Identified

More information

Integration of safety and security for effective control and protection of radioactive sources

Integration of safety and security for effective control and protection of radioactive sources Integration of safety and security for effective control and protection of radioactive sources International Conference on the Safety and Security of Radioactive Sources Ahmed Al Zaabi Overview 1. UAE

More information

SELF PRESERVATION SOCIETY By Jim Creak

SELF PRESERVATION SOCIETY By Jim Creak SELF PRESERVATION SOCIETY By Editor of the Means of Escape Magazine and Chairman of The Health & Safety Signs Association. w w w. m e a n s - of- e s c a p e. c o m Agenda Regulatory Reform Fire Safety

More information

BCRC-SEA s PROJECT: DEVELOPMENT OF REGIONAL TECHNICAL GUIDELINES FOR E-WASTE INVENTORY AND ESM 5R OF E-WASTE

BCRC-SEA s PROJECT: DEVELOPMENT OF REGIONAL TECHNICAL GUIDELINES FOR E-WASTE INVENTORY AND ESM 5R OF E-WASTE BCRC-SEA s PROJECT: DEVELOPMENT OF REGIONAL TECHNICAL GUIDELINES FOR E-WASTE INVENTORY AND ESM 5R OF E-WASTE Aboejoewono Aboeprajitno Director of BCRC-SEA BASEL CONVENTION REGIONAL CENTRE for South-East

More information

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment WALMART SUPPLIER FACTORY SAFETY ASSESSMENT OVERVIEW Wal-Mart Stores, Inc. ( Walmart ) engaged Bureau Veritas to conduct fire, building and electrical safety assessments at factories in Bangladesh designated

More information

Community Development and Recreation Committee

Community Development and Recreation Committee STAFF REPORT ACTION REQUIRED Results of the Fire Insurance Grades Study Date: November 20, 2013 To: From: Wards: Reference Number: Community Development and Recreation Committee Fire Chief and General

More information

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT Factory Address: Assessor: 1Plot # 4 (half) 8, 12 (half)-16, DEPZ (Old), Dhaka EPZ, Ganakbari, Ashulia, Savar Ashulia, Savar Dhaka Bangladesh Uttaron 25

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Factory Plot 47-52 & 68-73, KEPZ North Patenga Chittagong Chittagong 06 Mar 2017 The Alliance for Bangladesh Worker Safety Page 1/23 06 Mar 2017 Introduction

More information

NOTTINGHAM CITY HOMES

NOTTINGHAM CITY HOMES APPENDIX 1 NOTTINGHAM CITY HOMES FIRE SAFETY POLICY 2013/14 Draft for Board Uncontrolled when printed Page 1 of 14 DOCUMENT CONTROL Identification and Approval Status Document Title: Nottingham City Homes

More information

SUSTAINABLE URBAN DEVELOPMENT AND COHESION POLICY EUROPEAN COMMISSION. Urban Policy within the framework of EU Cohesion Policy

SUSTAINABLE URBAN DEVELOPMENT AND COHESION POLICY EUROPEAN COMMISSION. Urban Policy within the framework of EU Cohesion Policy Urban Policy within the framework of EU Cohesion Policy 2007-2013 16/09/2007 SUSTAINABLE URBAN DEVELOPMENT AND COHESION POLICY 2007-2013 Marco Orani European Commission Directorate General for 1 SUSTAINABLE

More information

Vietnam Scaling up Urban Upgrading Project (SUUP)

Vietnam Scaling up Urban Upgrading Project (SUUP) 1. Introduction Vietnam Scaling up Urban Upgrading Project (SUUP) Terms of Reference (TOR) Technical Advisory Services on Universally Accessible Infrastructure Design September 2018 The project is part

More information

Secretary of State determination under article 36 of the Fire Safety Order

Secretary of State determination under article 36 of the Fire Safety Order Fire and Rescue Service Circular Circular number 48/2009 Date issued 13 August 2009 This circular is For information and consideration Status This circular covers the outcome of a referral to the Secretary

More information

Midtown Greenway Land Use and Development Plan Executive Summary

Midtown Greenway Land Use and Development Plan Executive Summary Midtown Greenway Land Use and Development Plan Executive Summary Introduction The Midtown Greenway Land Use and Development Plan sets policy direction for land use and development in the Midtown Greenway

More information

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy Holme Grange School Whole School Policy Including EYFS Fire Safety Policy This document details the school s policy on fire safety in operation at Holme Grange School. The document is split into a number

More information

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years. Fire safety policy This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years. Contents 1. Policy principles 2 2. Statutory and Regulatory Framework

More information

UNECE Committee on Housing and Land Management activities on urban development

UNECE Committee on Housing and Land Management activities on urban development UNECE Committee on Housing and Land Management activities on urban development GULNARA ROLL, UN ECONOMIC COMMISSION FOR EUROPE HOUSING AND LAND MANAGEMENT UNIT Areas of work Sustainable Housing and Real

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Cha 72/1/C, Ground-4th FL, Progoti Swarani, Uttar Badda, Dhaka Dhaka The Alliance for Bangladesh Worker Safety Page 1/16 Introduction to the Report The following report contains

More information

World Trade Center Evacuations

World Trade Center Evacuations Lecture Overview World Trade Center Evacuations Rita Fahy Two studies of the World Trade Center - 1993 bombing - 9/11 attack Difference in methodologies for studies Findings Lessons learned Two events

More information

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT Factory Assessor: Plot #92 (Partial) DEPZ Extention Area-02 Ganakbari, Ashulia, Savar Uttaron 10 Feb 2014 The Alliance for Bangladesh Worker Safety Page

More information

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES MANAGING FIRE SAFETY LEARNING OUTCOMES On completion of this element, you should be able to demonstrate understanding of the content by applying what you have learnt to familiar and unfamiliar situations.

More information

TECHNICAL REPORT IEC TR 62987

TECHNICAL REPORT IEC TR 62987 TECHNICAL REPORT IEC TR 62987 Edition 1.0 2015-09 colour inside Nuclear power plants Instrumentation and control systems important to safety Use of Failure Mode and Effects Analysis (FMEA) and related

More information

Are you educated in safe emergency evacuation and fire safety risk assessments? Education: A Guide to Fire Safety

Are you educated in safe emergency evacuation and fire safety risk assessments? Education: A Guide to Fire Safety Are you educated in safe emergency evacuation and fire safety risk assessments? Education: A Guide to Fire Safety Managing fire risk within your school and providing an evacuation plan to all staff, pupils

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot # 33-36 Sector # 07, Chittagong Chittagong Chittagong 08 Jun 2014 The Alliance for Worker Safety Page 1/18 08 Jun 2014 Introduction to the Report

More information

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT) TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT) BRECON TOWERS BLACKBERRY LANE STOCKPORT SK5 8JW Date of this risk assessment review: 4th July 2017 Date of last risk assessment review: 8th May

More information

Community Service-Learning Program Evaluation Report for

Community Service-Learning Program Evaluation Report for Community Service-Learning Program Evaluation Report for 2009 2010 June 2011 Prepared by: Kendell Banack 2 Contents Statistics at a Glance.... 3 Introduction.. 4 Evaluation Methodology and Response Rates.5

More information

(Photos: Getty Images; Flickr) TAKEPART FEATURES Two Years After Factory Collapse, Fashion's Front Line Still Hopes fo Many workers in Bangladesh

(Photos: Getty Images; Flickr) TAKEPART FEATURES Two Years After Factory Collapse, Fashion's Front Line Still Hopes fo Many workers in Bangladesh (Photos: Getty Images; Flickr) TAKEPART FEATURES Two Years After Factory Collapse, Fashion's Front Line Still Hopes fo Many workers in Bangladesh haven't seen the improvements in working conditions that

More information

Understanding Passive Fire Protection

Understanding Passive Fire Protection ASFP Response to Hackitt Report/Scottish Regulatory Review What is Passive Fire Protection and why is it important? Niall Rowan Chief Executive Officer Association for Specialist Fire Protection Contents

More information

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT Factory Assessor: 33/1, Darail, Shataish Tongi, Gazipur Tongi, Gazipur Dhaka Emkay Enterprises 26 Feb 2014 The Alliance for Worker Safety Page 1/12 26 Feb

More information

INTRODUCTION TO TOWN PLANNING

INTRODUCTION TO TOWN PLANNING INTRODUCTION TO TOWN PLANNING What is planning? Definition of planning is subjective It is considered a science and art. It is pre-thinking and pre-arranging things. Planning is a future-oriented problem

More information

Strategies to Connect and Integrate Urban Planning and Environmental Planning Through Focusing On Sustainability : Case Study of Cheongju City, Korea.

Strategies to Connect and Integrate Urban Planning and Environmental Planning Through Focusing On Sustainability : Case Study of Cheongju City, Korea. Strategies to Connect and Integrate Urban Planning and Environmental Planning Through Focusing On Sustainability : Case Study of Cheongju City, Korea. Assistant Professor, Dept. of Urban Engineering, Chungbuk

More information

Emergency. Management. Emergency. Readiness Checklist

Emergency. Management. Emergency. Readiness Checklist Management Readiness Checklist Introduction Enclosed is your complimentary Readiness Checklist. This best-practice checklist will enable you to assess how well prepared you are for an emergency. It is

More information

Crystal Pool & Wellness Centre Stakeholder Engagement

Crystal Pool & Wellness Centre Stakeholder Engagement Crystal Pool & Wellness Centre Stakeholder Engagement Hosted by April 25 th, 2018 What We Will Be Presenting Today Summary of input gained through the February 2018 public engagement and online survey.

More information

Firefighting operations on automatic sprinklers systems F5-06 GD

Firefighting operations on automatic sprinklers systems F5-06 GD DESIGNER S GUIDE Firefighting operations on automatic sprinklers systems F5-06 GD Introduction When to use Scope Use this chapter to provide a consistent Fire and Emergency New Zealand position on design

More information

Fire Risk Assessment Guidance

Fire Risk Assessment Guidance Fire Risk Assessment Guidance This document is a guidance note to accompany the example fire risk assessment template. The example fire risk assessment template has been designed with small to medium domestic

More information

Bachelor of City Planning [BCP] (Hons)

Bachelor of City Planning [BCP] (Hons) November 2015 A/Prof Simon Pinnegar Discipline Director, Planning Bachelor of City Planning [BCP] (Hons) What s new? https://www.be.unsw.edu.au/undergraduate-degrees/city-planning/sydney-changing-were-also-changing

More information

Alarm Management Plan

Alarm Management Plan John E. Bogdan, Susan F. Booth, & David P. Garcia Abstract Why prepare an Alarm Management Plan just to meet PHMSA requirements (49 CFR Parts 192.631 and 195.446) when, for essentially the same effort,