Our mission. To be the best Greek company among the most developing European companies in Safety & Security Electronic Systems industry.

Size: px
Start display at page:

Download "Our mission. To be the best Greek company among the most developing European companies in Safety & Security Electronic Systems industry."

Transcription

1

2 Our mission To be the best Greek company among the most developing European companies in Safety & Security Electronic Systems industry.

3 Our history Olympia Electronics was established in 1979 by Nikolaos Lakasas and Panagiotis Arvanitidis. It is one of the oldest and largest Electrical & Electronic manufacturers in Greece The company employs over than 165 people. In 1981 Olympia Electronics entered in emergency lighting manufacturing process. In 1985 Olympia Electronics entered in fire alarm manufacturing process. In 1986 became the dominant firm in Greece as concerns Electronic Safety and Security industry

4 Our history In 1989 we are starting our export activities During 1990 and 1999 the company expands its products (9 families) while is remaining the dominant firm in the market. During 1999 and 2007 the company is awarded by many institutions for its successful & innovative business activities. On February 2005 Olympia Electronics gained the EFQM (European Foundation Quality for Management) recognition In 2014 the company inducts two new product families: emergency lighting and fire detection systems for marine applications. Today Olympia Electronics manufactures six main product categories and exports in 72 countries worldwide.

5 Our products We produce: Emergency lighting Emergency lighting for marine applications Fire Alarm Systems (conventional & analogue addressable) Fire Alarm Systems for marine applications Gas detection systems Security Alarm systems Nurse Call Systems Access Control (Card Switches) Movement detectors Electronic Room Thermostats Electronic Sirens Electrical fly traps (for HACCP systems) Electronic Elevator Systems (customised)

6 Quality We are certified for ISO 9001 by TUV, OHSAS 18001:2007 by Lloyd s Register, ISO 14000:2004 by Bureau Veritas Our products are certified by LLOYD S, BSI, TUV, VDS, LPCB, EVPU We have many local approvals like ELOT, ANKO, Gost, etc. We fulfil the European Norms i.e. EN , EN 54 etc. All our products have CE marking, DoC, Reach & RoHS. Since 2011 the company holds the bee bronze award of the European Business Ethics Network.

7 Our philosophy We produce high quality, state of the art and innovative products in a competitive price level. We are Easy To Do Business With company. Our orientation is a customer-centric one

8 Competitive advantage

9 SWOT analysis

10 Olympia Electronics strengths Leading position in the Greek market of emergency lighting and fire alarm systems. Complete product range. Targeting flexibility. Specific know-how for the lift industry concerning both software and electronics. OE already produces in an OEM basis for big global groups in the electronics, safety and security industry.

11 Olympia Electronics strengths Strong branding in the domestic market. - Synergies High market penetration in Greece. Increasing international orientation. Today, exports represent 70% of our sales. Strategic geographical position. Commitment to innovation and highly specialized human resources with capabilities for fast and effective new product development.

12 Our sales network (domestic) We are the dominant firm in the Greek market (more than 50% of the market share in emergency lighting and fire alarm) We have a branch office in Athens We cover all Greece with 12 well trained salesman

13 Our sales network (exports) Exports in 72 countries: European Union (71% of our exports) East European countries and Russia Middle East & Gulf countries Africa U.S.A (just started)

14 Our Sales Policy Our trading policy is a co-ordinated one. Our strategy is oriented to have a full efficiency to our distribution services. We promote our products through Electrical wholesalers, Consulting engineers, Security and fire equipment companies.

15 Project s references The vast majority of Olympic games Athens 2004 projects Athens Metro Prefecture of Vienna Expo Lisbon Portugal central building Metro Schwerin Germany Hilton & Sheraton Dubai Public Electricity Authority Dubai

16 Reference list Vessel Company Type Aegean Paradise African Juniper Ariadne Blue Galaxy Blue Horizon Blue Star 2 Blue Star 2 Naxos Blue Star Delos Blue Star Naxos Blue Star Paros Blue Star Patmos Blue Star1 Crete I Crete II Decameron Diagoras Eleni K Eleytherios Venizelos Elyros Galaxy Glikofilousa Golden Iris Hellenic Spirit Horizon Kiveli KK Perintis Kydon Leo Morocco Star New Hellas Olympic Champion Prevelis Superfast II Superfast XI Superfast XII Talos V.Kornaros Hainan Cruises/Etstur Sea Vision Hellenic Seaways Blue Star Blue Star Blue Star Blue Star Blue Star Blue Star Blue Star Blue Star Blue Star Anek Lines Anek Lines - Blue Star Kaiafas shipping Anek Lines Anek Lines Blue Star Theodoropoulos Mano Maritime LTD. Anek Lines Blue Star Monford management LTD. - Anek Lines Technomar Superfast - Anek Lines Anek Lines Superfast Superfast Superfast Creta Cargo Lane Lines Cruise Ship Bulk Carrier Passenger / Vehicle RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship Oil / Chemical tanker RO-RO/Passenger ship General Cargo RO-RO/Passenger ship Passenger / Vehicle RO-RO/Passenger ship RO-RO/Passenger ship Cruise Ship RO-RO/Passenger ship RO-RO/Passenger ship Bulk Carrrier Dredger RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship Crude oil tanker RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship RO-RO/Passenger ship Ro-Ro Cargo RO-RO/Passenger ship

17 Strategic point in the map A 1½ hour flight from the north of Greece takes you to: 52m 4,5m 23m 11m 9m 57m 4m 2,1m 62m 0,6m 5m 1

18 Our production Automated production facilities Use of S.M.T. (Surface Mounted Technology by SONY) Well trained and young employees

19 R&D Well educated R&D staff (16 employees) Capability of quick and effective new product development Innovation oriented Software & hardware capabilities

20 Our staff Our staff are our real strength, they are: Team oriented Professional Motivated Committed to the company s mission

21 Our expertise In-house specialists: In Electronics In Emergency Lighting In Fire alarm In CAD In Logistics

22 Our future Olympia Electronics looks forward to play a significant role in South-eastern Europe for the next decade in electrical and electronic market. We can say this with assurance of the need for the following: Quality orientation Expertise Competitiveness Product Awareness Total customer service

23 Sales per family (%)

24 Exports Structure (general)

25 Market Segments

26

27

28 Product families Fire Detection Emergency Lighting

29

30

31 Address Fire BSR-2104/MAR, BSR-2114/MAR Addressable fire detection panels 2 and 4 loops Addressable fire detection systems

32 Address Fire BSR-2104/MAR, BSR-2114/MAR Addressable fire detection panels 2 and 4 loops Dimensions in mm IP30 Produced in accordance with EN54-2, EN , 64 or 96 zone capability V AC mains power supply. It offers 2 or 4 fully monitored siren outputs with a rating of 24V / 0,5A and 6 programmable relays as well as a built in network circuit. Incorporated power supply with a rating of 24V/100W and built-in battery charger for 24V batteries with a capacity of up-to 12Ah. The panels offer an extensive list of adjustments and characteristics for the control of the installed devices and sirens. These parameters can easily be adjusted using a PC based program. The programming of the panel can also be done using a PC. Messages can be viewed on the big LCD (320x240 pixels) whereas LEDs are used to show basic operations such as alarms, faults and isolated sections The operation is done using the built-in 16 key keypad. There is also an incorporated safety lock and a thermal printer mounting position The maximum delay for the sirens is 4 minutes. Addressable fire detection systems

33 Analogue addressable system connection diagram MAX 150 devices Addressable detectors, manual call points & sirens in each loop Ability to connect conventional sirens in fully monitored siren outputs Note: Besides the addressable sirens attached on the loop there is the ability to connect extra conventional sirens outputs or connect only conventional sirens Addressable fire detection systems

34 Address Fire BSR-2104/MAR, BSR-2114/MAR System programming The programming can also be done using a PC Note: Fire detection panel can be connected to a PC with BMS-485 to a free USB port. Graphical interface CMI-1001 enables to have a visual indication of fire detection installation. Addressable fire detection systems

35 Address Fire BSR-2100/MAR Repeater panel for BSR-2104/MAR, BSR-2114/MAR IP30 BSR-2000/MAR panel is a repeater panel for addressable fire detection panels BSR-21XX/MAR. This panel has all the major indications and a large LCD display to indicate the state of the master panel. The repeater panel is power supplied by mains and in a power failure by batteries. Panel reapeters connection diagramm Dimensions in mm Addressable fire detection systems

36 Detectors for addressable fire detection panels Optical smoke / heat of rise IP44 IP22 BSR-6055/A/MAR Optical smoke detector BSR-6057/A/MAR Optical smoke/heat of rise detector BSR-6060/A/MAR Heat of rise detector Dimensions in mm Addressable fire detection systems

37 Isolator base for addressable fire detection panels IP20 BSR-7071/A/MAR is a bidirectional, non addressable loop monitoring device for addressable fire detection systems. It is power supplied by the loop and detects continuously the voltage levels and the signal's integrity. It is produced in accordance with EN 54-17, IEC , IEC Dimensions in mm Addressable fire detection systems

38 Fire detection call point for addressable fire detection panels BSR-5036/A/MAR Fire detection call point IP44 Dimensions in mm Addressable fire detection systems

39 Addressable input-output unit IP65 BSR-8020/WP/MAR is an addressable input output unit which cooperates and is exclusively programmable from fire control panels BSR-2104/MAR and BSR-2114/MAR. The use of this device is to connect conventional devices which have a free relay contact in addressable systems such as conventional fire detection & extinguishing panels, gas detection panels, conventional detectors, flow switches, electromagnetic door latches etc. This device is also used as a driving input unit for conventional detectors to the addressable panel with maximum capacity 10 conventional devices (detectors, manual call point) or as a driving input unit with external power supply and maximum capacity 32 conventional devices as per EN54 regulations. Dimensions in mm Addressable fire detection systems

40 Line Isolator IP20 BSR-7070/A/MAR is a bidirectional (two way), non addressable device which is used in addressable systems to sense and isolate short circuits on loops. It is power -supplied by the loop and detects continuously the voltage level and current flow. Its function is to isolate a part of the loop, remove the short circuit that is detected among two isolators. Dimensions in mm Addressable fire detection systems

41

42 Fire Sys BS-1638/MAR, BS-1642/MAR, BS-1646/MAR Fire Detection Panels 8, 12, and 16 Zones IP30 8, 12 & 16 zones Uniform operations, controls and indications 2 outputs for sirens, an alarm relay, a fault relay and an auxiliary relay. History memory Ethernet control and programming capability (card GR-8530) GR Network card through ETHERNET Conventional fire detection systems

43 Conventional detectors Beam smoke BS-655/MAR Optical smoke detector IP44 BS-657/MAR Smoke and heat detector BS-660/MAR Heat of rise detector with base Dimensions in mm Conventional fire detection systems

44 Conventional detector Heat Detector IP23 The Orbis range incorporates seven heat detector classes to suit a wide variety of operating conditions in which smoke detectors are unsuitable. The European standard EN54-5:2001 classifies heat detectors according to the highest ambient temperature in which they can safely be used without risk of false alarm. Dimensions in mm Heat detectors have a wide range of response characteristics and the choice of the right type for a particular application may not always seem straightforward. It is helpful to understand the way that heat detectors are classified as explained earlier and to memorise a simple rule: use the most sensitive heat detector available consistent with avoiding false alarms. If the fire detection system is being designed to comply with BS : 2002 heat detectors should be installed at heights of less than 12 metres with the exception of class A1 detectors, which can be installed at heights up to 13.5 metres. Conventional fire detection systems

45 Conventional base ORB-MB MAR Orbis Marine TimeSaver Base Diagrams Dimensions in mm Conventional fire detection systems

46 Conventional detector UV Flame detector Dimensions in mm The Marine Series 65 Base Mounted UV Flame Detector is designed to protect enclosed indoor areas where open flaming fires may be expected. The detector has a fast acting response to flames up to 25m away and is equipped with a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation. Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into MAR base (Fig 2) Zone-powered Conventional fire detection systems

47 Fire detection call point BS-536MAR Fire detection call point IP44 Dimensions in mm Conventional fire detection systems

48 Conventional manual call point IP67 WCP1A-R470SG-K is a conventional weatherproof manual call point which cooperates with every conventional fire detection system and all fire detection panels. It is constructed in accordance with EN 54-11, IEC , IEC The installation of manual call points enables a person to activate manually the fire alarm during his departure of the building. Dimensions in mm Conventional fire detection systems

49 Conventional siren with beacon IP42 IP65 BS-531/1/WP/MAR is a conventional siren unit, that has a sound indicator and a beacon. It cooperates with all conventional fire detection panels and it can be connected in the output of all addressable fire detection panels. The conventional siren has the capability to choose from 8 different tones and two frequency rates. The maximum sound level is 94 db at 1m. The appropriate place for mounting is about 2-3 meters above the floor. Dimensions in mm Conventional fire detection systems

50 Conventional antiexplosive Optical smoke detector IP23 Optical smoke detectors have always been recognised as good detectors for general use. They are regarded as particularly suitable for smouldering fires and escape routes. The performance of Orbis IS optical detectors is good in black as well as in white smoke. In this respect Orbis IS is different from traditional optical smoke detectors which perform far better in white smoke than in black. Orbis IS optical detectors are also designed to reduce significantly the incidence of false alarms through over-sensitivity to transient phenomena. Orbis IS optical detectors are recommended for use as general purpose smoke detectors for early warning of fire in most areas. Dimensions in mm Conventional fire detection systems

51 Conventional antiexplosive Heat detector IP23 Heat detectors are used in applications where smoke detectors are unsuitable. The Orbis IS range incorporates seven heat detector classes to suit a wide variety of operating conditions in which smoke detectors are unsuitable. Dimensions in mm Conventional fire detection systems

52 Conventional antiexplosive Multisensor smoke detector IP23 The multisensor smoke detector is a thermally enhanced smoke detector and as such will not give an alarm from heat alone. The optical sensor is identical to the one in the Orbis IS optical detector. Its sensitivity is, however, influenced by a heat sensing element which makes the detector more responsive to fastburning, flaming fires. Dimensions in mm Conventional fire detection systems

53 Conventional antiexplosive Base Dimensions in mm The terminals are: Positive IN Positive OUT Negative IN and OUT (common terminal) Remote LED negative connection Functional earth (screen) The terminal screws are captive screws and will not fall out of the terminals. The base is supplied with the screws unscrewed in order to avoid unnecessary work for the installer. The end-of-line resistor should be connected between the OUT+ and COM terminals. If it is required that all detectors be fitted with their LEDs facing the same direction the bases must be fitted to the ceiling observing the marking on the exterior which indicates the position of the LED. Conventional fire detection systems

54 Conventional manual antiexplosive Call point IP67 WCP1A-R470SG-K013-01IS is an intrinsically safe version of the conventional weatherproof manual call point which cooperates with every conventional fire detection system and all fire detection panels and is appropriate for installation in hazardous areas. It is constructed in accordance with EN 54-11, IEC , IEC This call point is manufactured to protect against other hazards, as defined in paragraph of annex II of the ATEX Directive 94/9/EC. It is intended for outdoor use within Intrinsically Safe (I.S.) systems using suitable I.S. barriers. The installation of manual call points enables a person to activate manually the fire alarm during his departure of the building. Dimensions in mm Conventional fire detection systems

55 Conventional antiexplosive Galvanic barrier CNP-399 Conventional Galvanic Barrier is installed in the safe area and ensures system integrity. Enables compliance with the ATEX directive Internal Systematic Diagram Conventional IS Configuration Conventional fire detection systems

56

57 Easy light GR-316/15L/MAR / GR-316/30L/MAR GR-308/15L/MAR / Maintained / Self-testing h Leds 15-30lm 7VA 8VA IP40 22m Mounting methods Dimensions in mm Photometric Data Emergency lighting

58 Comfort light GR-423/12L/MAR / GR-423/24L/MAR / GR-427/12L/MAR Maintained/ Self-testing h Leds lm 6,5 7VA IP42 20m Mounting methods Dimensions in mm Emergency lighting

59 Weather light GR-939/15L/MAR / GR-939/30L/MAR / GR-940/15L/MAR Maintained/ Self-testing h Leds lm 7VA 8,5VA IP65 24m Photometric Data Dimensions in mm Mounting methods Emergency lighting

60 Double easy light GR-392/L/MAR Maintained / Self-testing 3 h Leds 220lm 8VA IP40 22m Mounting methods Dimensions in mm Photometric Data Emergency lighting

61 Rect light GR-736/21L/MAR Maintained/ Self-testing 3 h Leds 150lm 7VA IP20 17m Mounting methods Dimensions in mm Emergency lighting

62 Eco light ZLD ZLD-28/34/44/EM/MAR Accessory for wall mounting (included in packaging) Maintained / Self-testing 3 h Leds lm 6,5VA 6,9VA IP m Installation methods Dimensions in mm Easy mounting Emergency lighting

63 Eco light MLD / DLD MLD-28D-34D/w/MAR Maintained 3 h Leds lm 7,5VA 8VA IP m Dimensions in mm Installation methods Emergency lighting

64 Marine photoluminescent Safety signs Emergency lighting

65 Thank you!

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases PRODUCT GUIDE Optical Detector Multisensor Detector Heat Detector Mounting Bases 2...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects

More information

Orbis IS Product Guide MAN 3041

Orbis IS Product Guide MAN 3041 Orbis IS Product Guide MAN 3041 TABLE OF CONTENTS Page No. 1 Introduction to Intrinsic Safety... 2 2 Range of Products... 3 3 Features of Orbis IS... 3 4 Choosing a Detector: Q & A... 3 5 Orbis IS Optical

More information

optical detector multisensor detector heat detector mounting bases product guide

optical detector multisensor detector heat detector mounting bases product guide optical detector multisensor detector heat detector mounting bases product guide ...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

EC TYPE EXAMINATION (MODULE B) CERTIFICATE EC TYPE EXAMINATION (MODULE B) CERTIFICATE This is to certify that: LLOYD'S REGISTER VERIFICATION LIMITED (LRV), specified as a notified body under the terms of The Merchant Shipping (Marine Equipment)

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Apollo Accreditation. Need further information? Visit

Apollo Accreditation. Need further information? Visit Product Catalogue 2016/2017 Apollo Accreditation Apollo products are certified in a global arena to meet the most exacting standards set by both our customers, and the dynamic and challenging environments

More information

Security Alarm Systems

Security Alarm Systems eclipse Security Alarm Systems Contents Introduction 2 System Configuration 3 Control Panels 4 Remote Keypads & Expanders 5 Communication Modules 6 Upload/Download 6 Specifications 7 Introduction Zeta

More information

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Why choose Fireray? Why use a Beam Smoke Detector? Product Range. Range Brochure Why use a? Beam smoke detectors are the wide area smoke detection technology of choice, offering both excellent detection and value for money. With a high area of coverage per unit (as high

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide. Who we are? - Nº 1 Spanish fire alarm systems manufacturer. - 25 years experience in the fire detection field. - 40 countries worldwide. Own engineering, design and factories. Total control of production

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47

More information

History. Copper Radiator manufacturing plant. Aluminium Radiator manufacturing plant

History. Copper Radiator manufacturing plant. Aluminium Radiator manufacturing plant History Copper Radiator manufacturing plant SABAH RADIATOR INDUSTRIES the first Complete Radiator manufacturing unit in the Middle East was established in the year 1996 with its modern factory located

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors Cerberus PRO OOH740, OOHC740 Automatic fire detectors ASAtechnology For the automatically addressable detector bus C-NET collective / conventional (OOH740 only) Signal processing with ASAtechnology Event-controlled

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS NOT YOUR STANDARD FIRE ALARM PANELS FLEXIBILITY, SPEED, INTELLIGENCE Digital, intelligent communication systems that deliver it all. We thrive on technology, innovation

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

ID50series. intelligent fire alarm panels

ID50series. intelligent fire alarm panels ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of

More information

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection DATASHEET S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red

More information

The new detector from Rafiki

The new detector from Rafiki The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have

More information

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF DETECTOR TYPE ED816 ZE 1 ZE 2 ZE 3 ZE 4 ZE 5 ZE 6 ZE 7 S ZE 8 CIRCUIT 1 ZE 9 ZE 10 ZE 11 ZE 12 ZE 13 ZE 14 ZE 15 ZE 16 CIRCUIT 1 POWER POWER SUPPLY GENERAL MENT DC GENERAL SYSTEM ALARM DELAYED ALARM RESOUND

More information

Wireless Fire & Security Solutions. Fire Product Showcase

Wireless Fire & Security Solutions. Fire Product Showcase Wireless Fire & Security Solutions Fire Product Showcase 2 Contents Contents 3 Product Overview 4-5 Control Panels 6-8 Control Panel Accessories / Power Supplies 9-10 Wireless Infrastructure 11-12 Aerials

More information

talentum Flame detection across the spectrum Range Brochure

talentum Flame detection across the spectrum Range Brochure talentum Flame detection across the spectrum Range Brochure Talentum - Why use our Flame Detectors... Talentum Flame Detectors are ideal for applications where fast acting and accurate detection of fire

More information

The EN54 Part 2 and 4 Fire System

The EN54 Part 2 and 4 Fire System Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire

More information

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS MINERVA S200Plus Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red solar blind flame detection for optimum

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty. Range Brochure Talentum - Why use our Flame Detectors? Product Range Talentum Flame Detectors are ideal for applications where fast acting and accurate detection of fire is essential. Using infra-red (IR)

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

LaserFOCUS VLF-250 Engineering Specification

LaserFOCUS VLF-250 Engineering Specification Vision Fire & Security LaserFOCUS VLF-250 Engineering Specification May 2004 Part Number 20296 LaserFOCUS VESDA 2 VESDA LaserFOCUS Contents Scope...4 Description...4 General...4 Approvals...4 Codes, Standards

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

Welcome to Morley IAS Fire Systems

Welcome to Morley IAS Fire Systems Welcome to Morley IAS Fire Systems A US $24B Corporation operating in 94 countries and employing 120,000 people Aerospace Consumer Products Group Electronic Materials Friction Materials Home & Building

More information

FIRE ALARM SYSTEM VER.15.1

FIRE ALARM SYSTEM VER.15.1 FIRE ALARM SYSTEM VER.15.1 TABLE OF CONTENTS AWEX brand since the company was set up in 2002, its clearly defined mission have been modern top quality products and clients satisfaction. We offer a full

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T TOCSIN i700 SERIES Addressable & Analogue Gas Detection System Addressable technology from International Gas Detectors. Typical System is 40% Faster to Install with Fewer Connections Improved Reliability

More information

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early

More information

End To End Optical Beam Smoke Detector. Additional Information

End To End Optical Beam Smoke Detector. Additional Information End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important

More information

Basic Fire Alarm SystemTraining. Arman Alnasar

Basic Fire Alarm SystemTraining. Arman Alnasar Basic Fire Alarm SystemTraining Arman Alnasar Agenda Introduction to Esser 10 min Product Overview 5 min Control Panels 30 min Detectors 20 min Field Devices Alarm Devices 20min 10 min Management & Interface

More information

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd.   Web:  ISO 9001:2015 certified Linear detection solution Product Brochure About Us Signaline is a comprehensive range of linear detection systems providing solutions for fire and water leak detection. Our linear detectors are 100% manufactured

More information

Turning expertise and innovations into marine solutions

Turning expertise and innovations into marine solutions Turning expertise and innovations into marine solutions This is United Technologies United Technologies United Technologies (UTC) provides a broad range of high-technology products and services to the

More information

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION DOCUMENT CONTROL NUMBER / MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION 1. INTRODUCTION The MR300 range of optical smoke detectors forms part of the M300 series of plug-in

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

Who we are? Spanish fire alarm systems manufacturer. Engineering team with more than 20 years of experience in the fire detection field.

Who we are? Spanish fire alarm systems manufacturer. Engineering team with more than 20 years of experience in the fire detection field. 1 Presentation 2 Presentation 3 Who we are? Spanish fire alarm systems manufacturer. Engineering team with more than 20 years of experience in the fire detection field. Own design 100% local components

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

SHORTFORM CATALOGUE some words about us... Olympia Electronics was founded in 1979 by Nikolaos Lakasas and Panagiotis Arvanitidis. Throughout these 31 years, the company is active in developing innovative

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23 Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices Approved to EN54-3/EN54-23 Setting the Standard EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm

More information

Fire Detection systems. UniVario industrial fire detectors for every job

Fire Detection systems. UniVario industrial fire detectors for every job Fire Detection systems UNIVARIO UniVario industrial fire detectors for every job THE ASSUR for industrial Minimax sets the standard in the field of developing custom-made fire protection systems, and these

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection The SharpEye 40/40I (IR3) Flame Detection combine state-of-the-art technology with rugged durability and be ready to reliably work in any situation. Dräger offers a wide variety of high-quality flame-detectors

More information

MULTIFUNCTIONAL SYSTEM

MULTIFUNCTIONAL SYSTEM * SIL2&SIL3 CPD EN-54 * UL Listed * GOST-R *Approvals under process * MULTIFUNCTIONAL SYSTEM SAFETY/SECURITY FIRE FIGHTING INTEGRATED SYSTEMS Standards and certifications In order to be used in fire fighting

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

VISION. Introduction. Dear readers and friends,

VISION. Introduction. Dear readers and friends, COMPANY PROFILE EN VISION Introduction Dear readers and friends, Rationalisation of the railway traffic on main lines, urban and mass transit as well as industrial lines requires in many areas the use

More information

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings GE Security EST Fire & Life Safety Sophisticated io-series Intelligent Life Safety Systems for small to mid-size buildings io Series Supports Signature Series intelligent detectors and modules Electronic

More information

Bernstein product overview

Bernstein product overview ITC Electrical Components is proud to announce that BERNSTEIN AG of Porta Westfalica, Germany has appointed ITC as their exclusive Canadian distributor. Bernstein product overview Sensor Systems Inductive

More information

AUTROSAFE. An interactive fire detection system for larger vessels

AUTROSAFE. An interactive fire detection system for larger vessels AUTROSAFE An interactive fire detection system for larger vessels AUTROSAFE AutroSafe interactive fire detection system is designed for the toughest requirements and expands the possibilities of a fire

More information

Monitoring Solutions

Monitoring Solutions GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Industrial fire alarm systems

Industrial fire alarm systems Industrial fire alarm systems Industrial fire alarm systems redefined. While fire alarm systems for standard applications, e.g. in offices and residential buildings, provide an enormous variety of solutions,

More information

Addressable Loop Powered Visual Alarm Devices

Addressable Loop Powered Visual Alarm Devices Addressable Loop Powered Visual Alarm Devices About Who is? has a long and proud tradition in fire detection. Founded in Munich in 1877 as Elektrotechnische Fabrik Alois it quickly became a recognized

More information

Medicontrol itcp Intelligent Theatre Control Panels

Medicontrol itcp Intelligent Theatre Control Panels Medicontrol itcp Intelligent Theatre Control Panels Medicontrol itcp Intelligent Theatre Control Panels Brandon Medical is a UK manufacturer and designer of world-leading technology for operating theatres,

More information

Reflective Optical Beam Smoke Detector User Guide

Reflective Optical Beam Smoke Detector User Guide Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating

More information

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION CEN/TC 305 Business Plan Page: 1 Business environment, benefits and priorities EXECUTIVE SUMMARY CEN/TC 305

More information

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

SUPREMATouch Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of

More information

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection Dräger Flame 2700 (Multi-IR) Flame Detection With its multichannel IR sensor the Dräger Flame 2700 detects hydrocarbon- and hydrogen-based fires. Thereby it offers a high reliability against false alarms.

More information

intelligent fire alarm ID60series panels

intelligent fire alarm ID60series panels intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as

More information

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2100 (UV) Flame Detection Dräger Flame 2100 (UV) Flame Detection A short response time and high reliability against false alarms are the features of the Dräger Flame 2100. Its UV sensor is quick to detect hydrocarbon- or hydrogen-based

More information

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS (68.52) X June 2000 supersedes February 2000 vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS VIGILON SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max loop length 1000m

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

SO SMART, YOU WILL CALL IT INTELLIGENT

SO SMART, YOU WILL CALL IT INTELLIGENT SO SMART, YOU WILL CALL IT INTELLIGENT THE RELIABLE FIRE PROTECTION SYSTEM YOU CAN COUNT ON. A conventional 2-wire fire alarm system is often the natural choice for smaller applications or where budget

More information

LAE10 LFE10. Use. Series 02

LAE10 LFE10. Use. Series 02 ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-A9-Ex Multisensor fire detector FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled

More information