VAN'S AIRCRAFT, INC. Step 0: Push 2nd button from left EFIS MENU BARO AP LISTS MORE EXIT. Step 8: Push "MORE"

Size: px
Start display at page:

Download "VAN'S AIRCRAFT, INC. Step 0: Push 2nd button from left EFIS MENU BARO AP LISTS MORE EXIT. Step 8: Push "MORE""

Transcription

1 Step 0: Push 2nd button from left EFIS R0 RELEASE /9/0 KLK R ISED SHEETS 3 AND 4 R2 ISED ALL SHEETS TO REMOVE ALL BUT IAS & DATALOG LOCKDOWN 0/9/0 KLK 08/6/3 Step : MENU BARO AP LISTS MORE EXIT EFIS INFO DIM TIMER MORE EXIT Push "" NOTES:. ALL SETTINGS NOT DEFINED BY THIS DRAWING ARE ACCEPTABLE AS CONFIGURED FROM MANUFACTURER. 2. LOCKED SETTINGS ARE SHOWN SHADED. PITCH CLOCK MORE BACK Push "" IAS: KNOTS ALT: FEET MORE BACK HDG BALL TURNRTAOABAR MORE BACK toggle OFF TEMP: CELCUS BARO: IN HG MORE BACK Step 0: CLOCK BARO ROLL: GTRK:Y MORE BACK DIST: NAUT M MORE BACK Step : WIND:YASTRND VSI:2K CDI:Y MORE BACK PITCH CLOCK MORE BACK Push "" CRS:Y TRIM MORE BACK ALTBAR ALTDIG IASBAR IASDIG MORE BACK DYNON D80 PRESETS DYNON SHEET OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

2 R2 08/6/3 Step : PITCH CLOCK MORE BACK VRSION IASCLR OAT ALTENC MORE BACK Push "IASCLR" Push "STYLE" IASCLR STYLE VSO VS VFE VNO VNE BACK Step 0: STYLE:MODERN BACK set to 4 set to 45 set to 82 set to 08 set to 36 VRSION IASCLR OAT ALTENC MORE BACK Push "ALTENC" Step : Push "HSI" ALTENC Push "DOWN \/" until "EFIS/EMS SERIAL>" is highlighted, then push "SEL" FRMAT: 4 RES: 0 FT BACK VRSION IASCLR OAT ALTENC MORE BACK, "MORE", "MORE" EFIS/EMS DATA PORT -EFIS SERIAL- INPUT: AUTO BAUD RATE: AUTO -EMS SERIAL- INPUT: NMEA BAUD RATE: 9600, "BACK" Push "BARO" BARO IN HG ADJUST AT BOOT:ON BACK SHEET 2 OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

3 Step : DATALOG AP MORE EXIT Push "DATALOG" R0 RELEASE /9/0 KLK R ADDED ALARM CONFIG SETTING R2 0/9/0 KLK 08/6/3 DATALOG CONFIG RECORDING: ON INTERVAL: SEC RECORD AT BOOT: YES MARK NOW, then "BACK", then "EXIT" GLOBAL -PILOT - ALARM CONFIG DATALOG CONFIG Push "DOWN \/" until "ALARM CONFIG" is highlighted, then push "SEL>" ERASE LOG ERASE MIN/MAX LOG ERASE SNAPSHOT LOG -SCREEN - INFO ITEM CONFIG ROTATION ORDER Push second button from right EMS MENU AUX FUEL MORE BACK EMS LISTS DIM TIMES MORE BACK Push "" -INSTALL - ENGINE TYPE: ROTAX HP RATING: N/A #OF CHT: 2 # OF EGT: 2 CYL DISP: SPLIT # OF FUEL TANKS: SET HOBBS TIME SET TACH TIME -LOCAL DATA PORT- EFIS/EMS SERIAL CLOCK VRSIONGLOBALSENSOR MORE BACK Push "SEL>" MAN PRESS: HG PRESSURE: PSI VOLUME: GALLONS ENGINE TEMP: FARNHT DISTANCE: NAUT MLS SPEED: KNOTS ALTITUDE: FEET OAT TEMP: CELCUS BARO: HG Push "GLOBAL" Step 0: ALARM CONFIG PWR ON ALARMS: ON LGT BHVR: DIM OUTPT TEST ALARM LIGHT TEST ALARM AUDIO, then "BACK" SHEET 3 OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

4 Step : CLOCK VRSIONGLOBALSENSOR MORE BACK Push "SENSOR" R0 RELEASE /9/0 KLK R STEP MOVED TO THIS SHEET FROM SHEET 3; RE-NUMBERED STEPS 2 THRU R2 Push "DOWN \/" until "OIL TEMP" is highlighted, then push "SEL>" 0/9/0 08/6/3 KLK Push "SEL>" TACHOMETER (RPM) POSITION: RIGHT ALARM: OFF PULS/ R:.0 PULS/ L:.0 CRUISE RPM: 5000 OIL TEMP ( F) ALARM: SELF-CLEAR SENSOR TYPE: 4 USING CUSTOM ENGINE DISPLAY SETTINGS USING CUSTOM ENGINE DISPLAY SETTINGS Push "DOWN \/" until "MANIFOLD PRES." is highlighted, then push "SEL>" MANIFOLD PRES. (INHG) POSITION: LEFT ALARM: OFF TOP RED: 40.0 HI RED/YEL: 40.0 HI YEL/GRN: 40.0 BOTTOM GRN:0.0 SENSOR TYPE: Step 0: Step : Push "DOWN \/" until "EGT" is highlighted, then push "SEL>" EGT ( F) - PAGE TOP OF 700 HI RED/YEL: 620 HI YEL/GRN: 470 LO GRN/YEL: 400 LO YEL/RED: 300 BOT OF 800 SCALE SECTIONS: 4 (EGT /SECT): NEXT PAGE -- Push "DOWN \/" until "OIL PRESSURE" is highlighted, then push "SEL>" OIL PRESSURE (PSI) TOP RED: 0 HI RED/YEL: 00 HI YEL/GRN: 73 LO GRN/YEL: 29 LO YEL/RED: 2 BOTTOM RED: 0 SENSOR TYPE: 4 SHEET 4 OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

5 R2 08/6/3 Step : Push "DOWN \/" until "CHT" is highlighted, then push "SEL>" Push "DOWN \/" until "FUEL FLOW" is highlighted, then push "SEL>" CHT ( F) - PAGE TOP OF 270 HI RED/YEL: 245 HI YEL/GRN: 230 LO GRN/YEL: 00 LO YEL/RED: 0 BOT OF 00 SCALE SECTIONS: 4 (CHT /SECT): NEXT PAGE -- FUEL FLOW (GPH) DISPLAY: TEXT K-VALUE: TOP RED:.0 HI RED/GRN: 0.0 BOTTOM GRN: 0.0 RETURN FLOW: Push "DOWN \/" until "FUEL LEVEL" is highlighted, then push "SEL>" Push "DOWN \/" until "VOLTAGE" is highlighted, then push "SEL>" FUEL LVL. (GALLONS) TANK NAME: MAIN LO GRN/YEL: 7.0 LO YEL/RED: 3.5 SENSOR TYPE: Step 0: VOLTAGE (VOLTS) TOP RED: 4.7 HI RED/YEL: 4.6 HI YEL/GRN: 4.3 LO GRN/YEL: 3.7 LO YEL/RED:.5 BOTTOM RED:.0 Push "DOWN \/" until "FUEL PRESSURE" is highlighted, then push "SEL>" DISPLAYED: INFO DISPLAYED: INFO 3 FUEL PRESSURE (PSI) DISPLAY: DIAL TOP RED: 6.0 HI RED/YEL: 5.8 HI YEL/GRN: 5.0 LO GRN/YEL: 3.0 LO YEL/RED: 0.7 BOTTOM RED: 0.0 SENSOR TYPE: SHEET 5 OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

6 R2 08/6/3 Step : Push "DOWN \/" until "CURRENT" is highlighted, then push "SEL>" Push "DOWN \/" until "EMS CONTACT " is highlighted, then push "SEL>" CURRENT (AMPS) TYPE: -60A TO 60A TOP RED: HI RED/YEL: HI YEL/GRN: +8.0 LO GRN/YEL: -2.0 LO YEL/RED: -5.0 BOT OF RED: -7.0 SENSOR TYPE: Step 0: EMS CONTACT NAME: SPAR CLSD LABEL: GOOD CLSD COLOR: GREEN OPEN LABEL: BAD_ OPEN COLOR: RED DISPLAYED: INFO 7 DISPLAYED: INFO 2 DISPLAYED: INFO 6 Push "DOWN \/" until "EMS GP INPUT " is highlighted, then push "SEL>" Step : Push "DOWN \/" until "EMS CONTACT 2" is highlighted, then push "SEL>" EMS GP IN ( F) FUNCT: ROTAX CHT L SEE CHT MENU FOR SETTINGS Push "DOWN \/" until "EMS GP INPUT 2" is highlighted, then push "SEL>" EMS GP IN 2 ( F) FUNCT: ROTAX CHT R EMS CONTACT 2 ALARM: OFF NAME: STAL CLSD LABEL: PUSH CLSD COLOR: RED OPEN LABEL: OPEN COLOR: BLACK DISPLAYED: INFO 7, then "BACK" SEE CHT MENU FOR SETTINGS Push "DOWN \/" until "EMS GP INPUT 3" is highlighted, then push "SEL>" EMS GP IN 3 FUNCT: TRIM ELEV SENSOR TYPE: SHEET 6 OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

7 R2 08/6/3 Step : CLOCK VRSIONGLOBALSENSOR MORE BACK Push "DOWN \/" until "ADD THRESHOLD" is highlighted, then push "SEL>" FUEL TRIM FLAPS DSAB MORE BACK Push "FUEL" Push "DOWN \/" until "FULL VALUE" is highlighted, then push "SEL>" ADD THRESHOLD (%) INCREASE: 20 ENTER A PERCENT (OF THE FULL TANK VALUE) INCREASE IN ANY TANK THAT WILL TRIGGER A PROMPT TO ADD FUEL TO THE FUEL COMPUTER AT BOOT., then "BACK", then "BACK", then "EXIT" FULL VALUE (GALS) LEVEL: 9.8 ENTER THE TOTAL AMOUNT OF FUEL BETWEEN ALL TANKS. THIS VALUE IS USED FOR FUEL REMAINING CALCULATION. When creating a lock file using the Dynon Support Program there exists the option to lock selected menus. Under EFIS display setup menus, the following menus must be locked: Airspeed Colors Under EFIS I/O setup menus, the following menus must be locked: Push "DOWN \/" until "PRESET VALUE" is highlighted, then push "SEL>" Datalog No other menus are to be locked. PRESET VALUE (GALS) LEVEL: 9.8 ENTER A PRESET AMOUNT OF FUEL BETWEEN ALL TANKS. THIS MAY BE A COMMON REFILL VALUETHAT IS NOT 00% FULL (I.E. 2 OF YOUR 4 TANKS). SHEET 7 OF 7 NUMBER PER PATH: Q:\\SYSTEMS\ELECTRICAL SYSTEM\.SLDDRW

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. A. Annunciator Panel - Serials

More information

Stratomaster Ultra. Owner's Manual. Installation guide. Stratomaster Ultra L Owner s manual. Model L MKII with RDAC V EIS.

Stratomaster Ultra. Owner's Manual. Installation guide. Stratomaster Ultra L Owner s manual. Model L MKII with RDAC V EIS. Stratomaster Ultra Model L MKII with RDAC V EIS Owner's Manual & Installation guide MGL Avionics Physical: 5 Fuchsia Street, Heldervue, Somerset West Postal: Postnet Suite 325, Private Bag X15, Somerset

More information

About This Manual through 12.xx

About This Manual through 12.xx FENCODER Operations, Programming & Installation Manual About This Manual This manual is divided into three sections 1) operations; 2) programming; 3) installation. All three sections are combined as the

More information

User and Installation Manual. Your journey, Our technology

User and Installation Manual. Your journey, Our technology Product model number: UX0EMS00AM Software: version 1.0.0R or more recent Firmware: version 1.0.0R or more recent User and Installation Manual Your journey, Our technology INDEX AvMap EngiBOX 1. Overview

More information

Siemens RDY2000BN. Start Up Guide

Siemens RDY2000BN. Start Up Guide Siemens RDY2000BN Start Up Guide Answers for infrastructure and cities. What this slide set is about This is a start up guide for the RDY2000BN BACnet Commercial Thermostat. This procedure show how to

More information

Stratomaster Smart Single

Stratomaster Smart Single Stratomaster Smart Single EMS-503 Fully integrated Engine Monitoring System for the Rotax 503 DCDI and similar two-stroke engines such as available from Hirth, 2SI and others. The EMS-503 unit is a 2.25

More information

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft AvSimMap_II.ac Avidyne map generic moving map AvSimMap_II_nobezel.ac Avidyne map generic moving map with bezel removed AvSimMFD_all.ac Avidyne MFD Avidyne Entegra MFD for Piper or Cirrus aircraft AvSimPFD_all.ac

More information

ATS UV Monitor Operations Manual

ATS UV Monitor Operations Manual ATS UV Monitor Operations Manual Version 1 as of 09-14 - 2012 Aqua Treatment Service, Inc 194 Hempt Road Mechanicsburg, PA 17050 717. 697. 4998 FA: (800) 787-0197 www.aquat.com Aqua Treatment Service,

More information

Blaze INFO-2. Information Display

Blaze INFO-2. Information Display Blaze INFO-2 Information Display Operating Manual English 1.00 G-force meter UTC and local time display Slip indicator Battery Voltage, *Current and Charge display OAT display Flight Timer & Flight log

More information

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF).

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF). TC-3 Twelve channel thermocouple (EGT/CHT) indicator Operating Manual English 1.00 Introduction The TC-3 thermocouple display unit is a 12 channel 3 1/8 instrument that contains all the features necessary

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Introduction. OM-THA2

Introduction. OM-THA2 Introduction. The OM-THA2 is a multi-function product that monitors Temperature, Humidity and Dew Point, provides alarms for out of range conditions, and continuously logs data. It consists of a base unit

More information

Homeowner s Guide / 1

Homeowner s Guide / 1 Overview Options Programming Your Homeowner s / 1 Message to the Homeowners Your premium Comfort Control 2 HD Communicating is designed to give you and your family the indoor comfort you desire. It s easy

More information

The TC-2 also records maximum temperatures reached for each channel in permanent memory.

The TC-2 also records maximum temperatures reached for each channel in permanent memory. Velocity TC-2 One to four channel thermocouple (EGT/CHT) indicator Operating Manual English 1.03 Introduction The TC-2 thermocouple display unit is a 4 channel 3 1/8 instrument that contains all the features

More information

INITIAL START-UP CHECKLIST FOR 19XR HERMETIC CENTRIFUGAL LIQUID CHILLER

INITIAL START-UP CHECKLIST FOR 19XR HERMETIC CENTRIFUGAL LIQUID CHILLER INITIAL START-UP CHECKLIST FOR 19XR HERMETIC CENTRIFUGAL LIQUID CHILLER (Remove and use for job file.) MACHINE INFORMATION: NAME JOB NO. ADDRESS MODEL CITY STATE ZIP S/N DESIGN CONDITIONS: TONS BRINE FLOW

More information

PPG meter instrument for power paragliding

PPG meter instrument for power paragliding 1 PPG meter instrument for power paragliding Power paragliding meter serves to telemetry basic parameters of your paramotor, to warrant calm and satisfied flight for you PPG meter is made in two version:

More information

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS Starting Serial No. "LH" This manual provides General Information, Installation, Operation, Maintenance and System Set-Up

More information

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY Introduction.

More information

QuadraTouch Pro Software Manual Dryer Control System

QuadraTouch Pro Software Manual Dryer Control System QuadraTouch Pro Software Manual Dryer Control System Software is constantly changing. Make sure you are up to date with Sukup s newest software. New software and manuals are available for download at:

More information

WeatherLink for Alarm Output Addendum

WeatherLink for Alarm Output Addendum WeatherLink for Alarm Output Addendum Introduction This Streaming Data Logger is designed to provide an electrical interface between a Vantage Pro or Vantage Pro2 weather station console or Weather Envoy

More information

1 and 2 Fan Vision Series Portable Dryers

1 and 2 Fan Vision Series Portable Dryers 1 and 2 Fan Vision Series Portable Dryers Operator s Manual PNEG-1456 Date: 09-29-09 PNEG-1456 2 PNEG-1456 1 and 2 Fan Vision Series Portable Dryers Table of Contents Contents Chapter 1 Safety... 5 Safety

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

Operators Manual. E15 Seeder Console Air Seeder Monitor A600 R1.3 V2.0.18

Operators Manual. E15 Seeder Console Air Seeder Monitor A600 R1.3 V2.0.18 Operators Manual E15 Seeder Console Air Seeder Monitor A600 R1.3 V2.0.18 How to use this operators manual As with any software operated equipment, software and/or hardware is in many cases changed and

More information

Metasys Integrator Cleaver-Brooks Application

Metasys Integrator Cleaver-Brooks Application Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Cleaver-Brooks Application lntroduction Page Application Details

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Warnings... 1 General Guidelines... 1 Firmware Version... 1 Environmental Conditions... 2 Electrical Specifications... 2 NSF Suggested Operation Ranges... 3 Applicable Sensor Operating Ranges... 3 Section

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Warnings... 1 General Guidelines... 2 Firmware Version... 2 Environmental Conditions... 2 Electrical Specifications... 2 NSF Suggested Operation Ranges... 3 Applicable Sensor Operation Ranges... 3 Section

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY INSTRUCTION MANUAL ENGINE MONITOR VOTT MODEL: 023-4400-0 3 YEAR WARRANTY INTRODUCTION The VOTT meter is an ideal engine monitor, which displays data via the J1939 CAN Bus. The meter utilizes a large LCD

More information

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers

More information

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control Created for Taylor-Wharton Gas Equipment By Pacer Digital Systems, Inc. INTRODUCTION... 4 TEXT FORMAT NOTATION... 4 SYSTEM COMPONENTS...

More information

725B Configuration Software Manual

725B Configuration Software Manual 725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...

More information

BP501G3 Tech Sheet. Part Number: Incoloy Incoloy Titanium. Custom Box Overlay Box Overlay Part Number N/A

BP501G3 Tech Sheet. Part Number: Incoloy Incoloy Titanium. Custom Box Overlay Box Overlay Part Number N/A BP501G3 Tech Sheet Customer: Balboa Water Group Part Number: 56582 800 Incoloy 56583 825 Incoloy 56584 Titanium Custom Box Overlay Box Overlay Part Number N/A UL System Model: BP501-BP501G3-AU Software

More information

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions Agenda Comfort Advantage System Configurations Installing ComfortNet ComfortNet Control Set up Dehumidification and Defrost Settings

More information

Follett Performance Plus

Follett Performance Plus Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen

More information

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information

BP2100G1 Tech Sheet. Customer: Balboa Water Group

BP2100G1 Tech Sheet. Customer: Balboa Water Group BP2100G1 Tech Sheet Customer: Balboa Water Group Part Number: 56389-01 800 Incoloy 56390-01 8250 Incoloy 56391-01 Titanium Custom Box Overlay Box Overlay Part Number N/A UL System Model: BP21-BP2100G1-RCA3.0K

More information

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm. DiaLog Elite 1 Prog Remote Monitoring, Control and 2 Run Alarm Notification System 5 SpkrPh 0 Status # Enter Quick Reference Guide Ack Clear Arm Reset Disarm Bksp Home Antx, inc. 2008 RUN Mode Commands

More information

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL for TLS-300 and TLS-350 UST Monitoring Systems and TLS-350R Environmental & Inventory Management System through Software Versions 15/115 Manual Number

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER

INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER (Remove and use for job file.) MACHINE INFORMATION: NAME ADDRESS JOB NO. MODEL CITY STATE ZIP S/N DESIGN CONDITIONS: TONS BRINE FLOW RATE

More information

Rev UltraSite User s Guide BCU Supplement

Rev UltraSite User s Guide BCU Supplement 026-1004 Rev 1 09-04-97 UltraSite User s Guide BCU Supplement Computer Process Controls, Inc. 1640 Airport Road Suite #104 Kennesaw, GA 31044 Phone (770) 425-2724 Fax (770) 425-9319 ALL RIGHTS RESERVED

More information

The latest development in material characterization and polymer processing. Rheometer Services Inc.

The latest development in material characterization and polymer processing. Rheometer Services Inc. The latest development in material characterization and polymer processing Rheometer Services Inc. rs5000-s1 Polymer Prep Station New solutions for material characterization and polymer processing rs5000

More information

ADS-B and Transponder

ADS-B and Transponder 2018 PRICE LIST R1 ADS-B and Transponder Model Part Number DESCRIPTION LIST PRICE STX 360 706430-00 The STX 360 is a UAT In and Out ADS-B unit with built-in Mode C Transponder. The units fits the same

More information

AIRDATA COMPUTER ALTITUDE ENCODER AVIONICS COOLING FANS. Model Part Number LIST PRICE DESCRIPTION

AIRDATA COMPUTER ALTITUDE ENCODER AVIONICS COOLING FANS. Model Part Number LIST PRICE DESCRIPTION 2015 PRICE LIST AIRDATA COMPUTER Model Part Number DESCRIPTION LIST PRICE SAC 7-35 705548-00 SAC 7-35-01 705548-01 The TSO d SAC 7-35 is an airdata/fuel system designed for todays integrated navigation

More information

EXPERT TRI-STAR. Temperature controller. User s Manual

EXPERT TRI-STAR. Temperature controller. User s Manual Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,

More information

The TC-1 also records maximum temperatures reached for each channel in permanent memory.

The TC-1 also records maximum temperatures reached for each channel in permanent memory. TC-1 One to four channel thermocouple temperature display Operating Manual English 1.00 Introduction The TC-1 thermocouple display unit is a 4 channel 2.25 instrument that contains all the features necessary

More information

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa

More information

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

Programmable Touchscreen Thermostats. Disconnect power before beginning installation. Installer Guide Touchscreen Programmable Touchscreen Thermostats 6100 Single Stage Heat / Cool Conventional or Heat Pump 6300 Up to 4 Heat / 2 Cool Heat Pump Up to 3 Heat / 2 Cool Conventional 6400 Up

More information

Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual

Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail:

More information

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...

More information

INTRODUCTION WHAT THE EMS-1000 IS DESIGNED TO DO HOW THE EMS-1000 OPERATES EMS CONTROL PANEL INITIAL SETUP SETUP CLOCK DIGITAL DISPLAY

INTRODUCTION WHAT THE EMS-1000 IS DESIGNED TO DO HOW THE EMS-1000 OPERATES EMS CONTROL PANEL INITIAL SETUP SETUP CLOCK DIGITAL DISPLAY INTRODUCTION WHAT THE EMS-1000 IS DESIGNED TO DO HOW THE EMS-1000 OPERATES EMS CONTROL PANEL INITIAL SETUP SETUP CLOCK DIGITAL DISPLAY NIGHT & DAY CHANGEOVER ROOM STATUS PRESET ROOM STATUS TEMPERATUR CONTROLS

More information

G1000TM. annunciations and alerts pilot s guide for the Diamond DA40

G1000TM. annunciations and alerts pilot s guide for the Diamond DA40 G1000TM annunciations and alerts pilot s guide for the Diamond DA40 Record of Revisions Revision Date of Revision Revision Page Range Description A 02/14/05 9-1 9-19 Initial release. B 06/01/05 9-5 Added

More information

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel

More information

Comfort Control 2 HD Thermostat

Comfort Control 2 HD Thermostat INSTALLER GUIDE Comfort Control 2 HD featuring Serial Communications FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL AND SYSTEM COULD CAUSE PERSONAL INJURY

More information

USER MANUAL USB Multi-Function Datalogger Model RHT35

USER MANUAL USB Multi-Function Datalogger Model RHT35 USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable

More information

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517) 3 4 Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1386 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number

More information

USER & INSTALLATION GUIDE

USER & INSTALLATION GUIDE Reach Plus At Home Alarm Unit Touch Personal Pendant USER & INSTALLATION GUIDE www.tynetec.co.uk SECTION 1 USER INSTRUCTIONS Section Topic Page 1.1 Important Information 3 1.2 Unpacking the Reach Plus

More information

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL TABLE OF CONTENTS DESIGN FEATURES OVERVIEW... 1 Viewing Head Selection...1 USER INTERFACE OVERVIEW... 1 Default Settings...2 Numerical configuration...2

More information

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314) Operator's Manual TABLE OF CONTENTS Firmware Version... 1 Environmental Conditions... 1 Electrical Specifications... 1 Warnings... 2 Section A: Programming the Controller... 3 A 1: Adjusting the Display

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000. INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA

More information

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet The following information must be completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Date of Installation:

More information

Dimlux maxi controller EVO1 (1.1)

Dimlux maxi controller EVO1 (1.1) Dimlux maxi controller EVO1 (1.1) (Datalog) Contents: -Introduction Pag. 2 -Components Pag. 2-4 -Connecting the lighting Pag. 4 -Connecting the CO2 Pag. 5 -Connecting aux/fan Pag. 5 Connecting the VPD

More information

ISIS USERS MANUAL I.S.I.S. 550B

ISIS USERS MANUAL I.S.I.S. 550B ISIS USERS MANUAL I.S.I.S. 550B INDUSTRIES, I.S.I.S. DIVISION Copyright 2004 RGM Industries I.S.I.S. Division. All rights Reserved 1 Topic Table of Contents Page No. I. General A. Warranty 1-3 B. ISIS

More information

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS Firmware version 5.02 This manual provides General Information, Installation, Operation, Maintenance and System Set-Up Information for METRON Model FD-4 Engine

More information

DEIF A/S. Operator s Manual. Basic Gen-set Controller. Display readings. Push-button functions. Alarm handling. Log list C (UK)

DEIF A/S. Operator s Manual. Basic Gen-set Controller. Display readings. Push-button functions. Alarm handling. Log list C (UK) Basic Gen-set Controller 4189340315C (UK) Display readings Push-button functions Alarm handling Log list DEIF A/S DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614 9615 DK-7800 Skive, Denmark

More information

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 026-1501 Rev 5 3-20-03 Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS

More information

2 & 3 Module DriTek Plus Dryers

2 & 3 Module DriTek Plus Dryers OPERATOR S MANUAL 2 & 3 Module DriTek Plus Dryers Division of ffi Corporation 1004 E. Illinois St. Assumption, IL 62510 PNEG-1540 Date: 09-15-2006 PNEG-1540 CONTENTS INTRODUCTION...4 OPERATING PRECAUTIONS...4

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

200i/KN2, KN4 Firmware Revision Sheet

200i/KN2, KN4 Firmware Revision Sheet 200i/KN2, KN4 Firmware Revision Sheet Revision 2.9 Special Release 1- November 2013 1. Added an external boiler Failsafe feature. The J6 Analog Output can be used to enable a SSR which can be used to enable

More information

SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.

SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications. HGM300 / RDM800 Refrigerant Monitoring System Instruction 3015-4149 Installation & Operation Mini Manual Rev. 5 November 2004 SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.

More information

Quick Setup Guide for IntelliAg Model NTA607HD

Quick Setup Guide for IntelliAg Model NTA607HD STEP 1: Pre-Programming Preparation: STEP 3: Row Status/Row Width Setup Press Row I/O button. Enter desired values using Table A as reference. Press Work Screen button to return to the Main Work screen.

More information

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006 1600 Gas Controller User s Manual Version 3.2 September 1, 2006 Industrial Scientific Corporation 1 INTRODUCTION... 1 1.1 GENERAL OPERATION... 1 1.1.1 Power Up... 1 1.1.2 Viewing Sensors... 2 1.1.3 Acknowledging

More information

SmarTemp Control fx 2.0

SmarTemp Control fx 2.0 Digital Timer Interface Installation / Operation Instructions General Thank you for choosing Webasto to meet your heating needs. The Webasto SmarTemp Control fx 2.0 enables you to preset start-up cycles

More information

Metasys Integrator Vilter Application

Metasys Integrator Vilter Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 1294 APPLICATION NOTE Metasys Integrator Vilter Application lntroduction Page 3 Application Details *3

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. The annunciator assembly

More information

Installation and User Guide

Installation and User Guide Installation and User Guide User CTS 2 602 manual by Nilan VPM 360 Modbus Version: 2.00 08-05-2014 Software-version: 2.20 The following information describes how to connect to Nilan CTS 602 controls by

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

MicroTech Series 200 Centrifugal Chiller

MicroTech Series 200 Centrifugal Chiller Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History

More information

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual Table of Contents Introduction 1 System Components 2 Wiring Block Diagram 3 Connection Diagram for One Sensor 4 Connection Diagram for Multiple

More information

RAE Systems Systems. User Presentation. October Protection Through Detection

RAE Systems Systems. User Presentation. October Protection Through Detection RAE Systems Systems AreaRAE Inert User Presentation October 2009 www.raesystems.com AGENDA Overview & Features Basic Operation Turning the AreaRAE Inert monitor ON Warnings NORMAL & INERT Mode Displays

More information

User s Manual DCU 305 R3 DCU 305 R3 LT. Diesel Engine Control Unit. Auto-Maskin

User s Manual DCU 305 R3 DCU 305 R3 LT. Diesel Engine Control Unit. Auto-Maskin User s Manual DCU 305 R3 DCU 305 R3 LT Diesel Engine Control Unit Auto-Maskin Content Document information 2 Introduction 3 ABOUT THIS MANUAL 3 ABOUT THE DCU 305 R3 & R3 LT 3 CERTIFICATES 4 TECHNICAL SPECIFICATIONS

More information

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number: (31/03/05) Version 2.604 p1 Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630047 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. Programming Methods... 3 1. Introduction 1.1 System Overview...

More information

ZITON RADIO LOOP MODULE

ZITON RADIO LOOP MODULE ZITON RADIO LOOP MODULE PROGRAMMING MANUAL Table of Contents Section Page No 1.0 INTRODUCTION...3 1.1 System Design...3 1.2 Handling Precautions...3 1.3 Packaging:...3 2.0 MENU STRUCTURE...4 2.1 Menu Structure

More information

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,

More information

INSTALLATIONN GUIDE & OPERATION MANUAL

INSTALLATIONN GUIDE & OPERATION MANUAL INSTALLATION INSTRUCTIONS ECO # 1569 REVISION #0006 FCS SERIES MODEL 5025, 5045,7525 & 7545 INSTALLATION INSTRUCTIONS BY: DATE: 01/23/2013 INSTALLATIONN GUIDE & OPERATION MANUAL MOTOR OPERATOR (V3.02 Controls)

More information

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS SCADA INTERFACE INSTRUCTIONS - OPTION 21Q - FOR A36D/TPSD SYSTEMS with 500 and 550 option. A36D/TPSD Modbus TCP SCADA INTERFACE OPTION 21Q INSTRUCTIONS This manual is valid for A36D/TPSD Chargers equipped

More information

Xtralis VESDA LCD Programmer Quick Reference Guide

Xtralis VESDA LCD Programmer Quick Reference Guide Xtralis VESDA LCD Programmer Quick Guide Xtralis VESDA VLP Xtralis VESDA VLS Xtralis VESDA VLC Scope of this Manual This manual is to be used as a quick reference guide to perform the initial detector

More information

ACDU02 Communicating Service Tool

ACDU02 Communicating Service Tool ACDU02 Communicating Service Tool Operation Manual 97B0106N01 Rev.: 4/17/14 Caution: These instructions are intended to be used by the installer or service personnel. End users are NOT advised to change

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

Manitex Operation Manual

Manitex Operation Manual Manitex Operation Manual Introduction The Greer Insight system is designed for use as an aid to crane operation. Do not use this system without a properly trained operator who is knowledgeable in safety

More information

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES P R O D U C T S P E C I F I C AT I O N S C O N T R O L S TOUCHSCREEN COMFORTSENSE 7000 7-Day Programmable Thermostat Bulletin No. 210515 June 2009 Supersedes February 2008 HOME SCHEDULE OPTIONS SET AT

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

Modbus RTU RS485 Manual

Modbus RTU RS485 Manual Modbus RTU RS485 Manual AUTOMATED FUEL MAINTENANCE SYSTEMS FTI-5A, FTI-10A, FTI-20A FUEL TECHNOLOGIES INTERNATIONAL 06/10/2014 Rev B - Fuel Technologies - Modbus The Modbus Communications Setup Button

More information

BC-4000 Bilge Monitor/Controller Installation Manual

BC-4000 Bilge Monitor/Controller Installation Manual SMART SWITCH TECHNOLOGIES BC-4000 Bilge Monitor/Controller Installation Manual Table of Contents Introduction 1 System Overview 1 System Overview (cont.) 2 Wiring Block Diagram 3 System Layout 4 Wiring

More information

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207 OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER Monitor AMT208 On-line Logger AMT207 1 INTRODUCTION Thank you for purchasing AMTAST s Wall mount/desktop Temperature, Humidity monitor /online

More information

4CH SD 720P MDVR User Manual

4CH SD 720P MDVR User Manual 4CH SD 720P MDVR User Manual Model: HZ-VN-2001-4S EN SHENZHEN COOINTECH TECHNOLOGY CO., LTD. www.coointech.com COPYRIGHT 2016 Shenzhen Coointech Technology Co., Ltd. This manual is copyrighted with all

More information

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System Quick-Start Installation Guide Document Number 44I00-1 Rev. 2.12 February, 2006 For complete operation and programming instructions,

More information