INSTALLATION AND OPERATION MANUAL

Size: px
Start display at page:

Download "INSTALLATION AND OPERATION MANUAL"

Transcription

1 INSTALLATION AND MANUAL IMPORTANT: RETAIN THESE INSTRUCTIONS FOR THE END USER. DO NOT DISCARD. CEILING OCCUPANCY SENSOR ITSCS ITSCSHB DIMMING POWER PACK ITSRPFAM2U ITSRPFAM4U ITSRPHDF2U ITSRPHDF4U INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Made in U.S.A. Technical/Sales assistance: P/N B0 Lightolier Controls is a is Philips a Philips Controls Controls brand brand

2 INSTALLATION & Important Safeguards When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not use outdoors. c. Do not mount near gas or electric heaters. d. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. e. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. f. Do not use this equipment for other than intended use. g. Refer service to qualified personnel. SAVE THESE INSTRUCTIONS. WARNING: You must have access to a main circuit breaker or other power disconnect device before installing any wiring. Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation. Installing the device with power on may expose you to dangerous voltage and damage the device. A qualified electrician must perform this installation. WARNING: Refer to National Electrical Code and local codes for cable specifications. Failure to use proper cable can result in damage to equipment or danger to persons. CAUTION: Wire openings MUST have fittings or lining to protect wires/cables from damage. Use 90 C copper wire only! Important Safeguards

3 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Table of Contents Quick Start...2 Preface...2 Description...3 Installation: Ceiling Occupancy Sensor...4 Installation: Dimming Power Packs...5 Mounting...5 Low Voltage and Line Wiring...6 Using the Programming Remote...9 Programming Mode...9 Selecting Devices...9 Programming: Ceiling Occupancy Sensor...10 Mode...10 Time...11 Relay Selection...11 Sensitivity...12 Occupancy Photocell Sensitivity...12 Miscellaneous...13 Switch Programming Mode (Relay Pack Inputs or Network-Connected LSW Series Keypads)...13 Switch Mode...14 Relay On Select...15 Relay Off Select...16 Assigning a Scene To a Switch...16 Adjusting Scene Dimmer Levels (ITSPCS & ITSCS Units Version 2)...17 Test...18 Display...18 Example Setup...19 Manual Configuration: Ceiling Occupancy Sensor...22 Power Pack Primary/Secondary Mode Selection...24 Troubleshooting Guide...25 Specifications...26 Please check the Lightolier Controls web site, for updated product information. Table of Contents 1

4 INSTALLATION & Quick Start 1. Install Dimming Power Packs. 2. Install Ceiling Occupancy Sensors. 3. Install one Photocell Daylighting Sensor, if daylighting is required. 4. Install keypad(s), if required. 5. Connect 4-wire ITS network between all of the above devices. 6. Power up Dimming Power Packs and verify the following: a. Dimming Power Packs blink red and/or green once every second. b. ITSCS Sensor blinks red every 10 seconds. c. ITSPCS Sensor blinks. 7. Test system and network as follows: a. At keypad, tap ON and OFF buttons. All relays should turn on and off, and pressed buttons should light up. b. Using IntelliSight Programming Remote, select any sensor using the PGM and LASER buttons while aimed at a sensor, then tap buttons 1-8 to toggle individual relays or the 0 button to toggle all relays. Tap EXIT button to exit test. (This is also useful to determine which circuits are controlled by which relays.) c. Using IntelliSight Programming Remote, select any Occupancy Sensor using the PGM and LASER buttons while aimed at a sensor, then tap FIELD/SELECT button. The selected sensor should turn blue/red and all other ITSCS Sensors should turn blue. Tap EXIT button to exit. Preface The document provides programming and installation instructions for the following IntelliSight products: ITSCS - IntelliSight Ceiling Occupancy Sensor ITSCSHB - IntelliSight High Bay Ceiling Occupancy Sensor ITSPCS - IntelliSight Photocell Daylighting Sensor ITSRPHDF2U - IntelliSight Dimming Power Pack, 2 Relay, Dual HDF, Universal Voltage (120~277 VAC) ITSRPHDF4U - IntelliSight Dimming Power Pack, 4 Relay, Dual HDF, Universal Voltage (120~277 VAC) ITSRPFAM2U - IntelliSight Dimming Power Pack, 2 Relay, Dual Mark 7, 0-10V Universal Voltage (120~277 VAC) ITSRPFAM4U- IntelliSight Dimming Power Pack, 4 Relay, Dual Mark 7, 0-10V Universal Voltage (120~277 VAC) ITSRP1U IntelliSight Relay Power Pack, 1 Relay, Universal Voltage (120 ~ 277 VAC) ITSRP2U IntelliSight Relay Power Pack, 2 Relay, Universal Voltage (120 ~ 277 VAC) ITSRP4U IntelliSight Relay Power Pack, 4 Relay, Universal Voltage (120 ~ 277 VAC) Please read all instructions before installing or using this product. Retain this guide for future reference. IMPORTANT INFORMATION. PLEASE READ! This unit is intended for installation in accordance with the National Electric Code and local regulations. It is also intended for permanent installation in indoor applications only. Before any electrical work is performed, disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform this installation. 2 Quick Start

5 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Description IntelliSight Ceiling Occupancy Sensor (ITSCS, ITSCSHB) The IntelliSight Low-Voltage Ceiling Occupancy Sensor is a multiple technology, occupancy-sensing low-voltage device that is designed for use with one or more IntelliSight System Relay Packs. Each unit provides automatic on/off, or manual on, operations using a wall-mounted switch. Up to eight sensors can be used with each relay power pack, and up to two dimming power packs can be controlled by one sensor. IntelliSight Photocell Daylighting Sensor (ITSPCS) The IntelliSight Low-Voltage Photocell Daylighting Sensor is a low-voltage device designed for use with one or more IntelliSight System Power Packs. Each unit provides dimming and bi-level switching control of up to two dimming power packs. IntelliSight Dimming Power Packs (ITSRPFAM2U, ITSRPFAM4U, ITSRPHDF2U, ITSRPHDF4U, ITSRP1U, ITSRP2U, ITSRP4U) The IntelliSight Universal Voltage Dimming Power Packs come in dual and quad relay configurations and operate with IntelliSight low-voltage ceiling and wall-mounted occupancy, and photocell (daylight harvesting) sensors. Each IntelliSight dimming power pack supports up to eight sensors. Lytemode Programming Remote (ITSIR1 or ITSIR2) The Lytemode Ceiling Occupancy Sensor Programming Remote is an optional accessory which provides quick and easy access to the full range of Occupancy Sensor features. Description 3

6 INSTALLATION & Installation: Ceiling Occupancy Sensor The Ceiling Occupancy Sensor may be mounted in a junction box or directly to the ceiling depending on local code. The unit must have an unobstructed view of the area to be monitored and must be mounted perpendicular to the floor below. If the unit is subject to "false triggering" from activity beyond the desired area of coverage, a portion of the lens may be masked to achieve the desired response. Simply install the Field of View Customizing Template (provided). To install: 1. Check for any obstructions located behind the desired mounting location. 2. Drill 1-1/2" hole in the desired mounting location. 3. Place Ceiling Occupancy Sensor through the hole and secure with supplied washer and locknut. 4. The lens may be removed to install the Field of View Customizing Template*. Simply rotate the lens cover slightly counter-clockwise and remove. 5. Trim the template for the desired effect and install on interior of the lens. (Careful placement of the template is necessary to ensure proper function.) 6. Replace lens cover and verify that the unit is securely mounted. RETAINING NUT WASHER LOW VOLTAGE WIRE NOTE: Sensors must be mounted perpendicular to the floor. Figure 1: Installing the Ceiling Occupancy Sensor * The Field of View Customizing Template is used to block the ITSCS in areas where motion should not trigger the sensor. 4 Installation: Ceiling Occupancy Sensor

7 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Installation: Dimming Power Packs MOUNTING WARNING: Before installing device, ensure that all power has been disconnected at circuit breaker to avoid risk of shock or damage to the unit. Always follow local wiring codes. To install dimming power pack(s): 1. Locate a suitable mounting location adjacent to a junction box where line wiring is to connect. 2. Route wiring through 3/4" knock-out on junction box and secure the included 3/4" nipple or nipples to junction box. All power leads must be pulled into existing junction box. 3. Securely mount dimming power pack using the included 3/4" nipple(s) and attached mounting brackets. 4. Connect power leads according to the following sections. Figure 2: Mounting the Dimming Power Pack(s) Installation: Dimming Power Packs 5

8 INSTALLATION & Installation: Dimming Power Packs (continued) WARNING: Before installing device, ensure that all power has been disconnected at circuit breaker to avoid risk of shock or damage to the unit. Always follow local wiring codes. LOW VOLTAGE AND LINE WIRING To connect wiring: 1. If conduit is required by local code, route low voltage wiring into adjacent junction box and secure with included 1/2" nipple. 2. Connect low voltage network with Belden 8723 stranded two-pair conductor or standard Cat5e stranded cable (or equivalent) according to the following diagrams, depending on which model dimming power pack you are installing. 3. Connect all power leads within adjoining junction box according to the following diagrams, depending on which model dimming power pack you are installing. NOTE: Control inputs are designed to be enabled by a 12v to 24v (DC or AC) signal. ITSRPHDF4U GREEN (DATA -) WHITE/GREEN (DATA +) BLACK (GROUND) RED (+12VDC) CONTROL INPUTS ORANGE BROWN To Additional Sensors ITSCS ITSCS NOTES: YELLOW (PRIMARY/SECONDARY SELECT) 1) Up to 8 digital devices (sensors, button stations, etc.) may be linked in parallel. 2) Orange and Brown control input wires are not polarity sensitive. Figure 3: Connecting HDF Dimming Power Pack Wiring 6 Installation: Dimming Power Packs

9 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Installation: Dimming Power Packs (continued) 4. Both Orange and Brown inputs are optically isolated from Power Pack low-voltage circuit and can be alternately powered by an external circuit 12-24V AC or DC. When voltage is detected, the inputs will turn their programmed Power Packs on (or off). This can be used for emergency or load shedding applications, and for a forced-on (or forced-off) switch. GREEN (DATA -) WHITE/GREEN (DATA +) BLACK (GROUND) ITSRPFAM4U RED (+12VDC) CONTROL INPUTS ORANGE BROWN To Additional Sensors ITSCS ITSCS YELLOW (PRIMARY/SECONDARY SELECT) VIOLET (FAM 1) GREY (FAM 1) VIOLET/WHITE (FAM 2) GREY/WHITE (FAM 2) To Advance Mark 7 Dimming Ballast NOTE: Ballast control wires must NOT be in the same conduit as switched hot. NOTES: 1) Up to 8 digital devices (sensors, button stations, etc.) may be linked in parallel. 2) Orange and Brown control input wires are not polarity sensitive. Figure 4: Connecting FAM Dimming Power Pack Wiring Installation: Dimming Power Packs 7

10 INSTALLATION & Installation: Dimming Power Packs (continued) NOTE: Control inputs are designed to be enabled by a 12v to 24v (DC or AC) signal. GREEN (DATA -) WHITE/GREEN (DATA +) BLACK (GROUND) RED (+12VDC) ORANGE BROWN ITSCS ITSCS ON OFF LSW2BCD To ILS NETWORK ORANGE SYSTEM MANUAL ON * BROWN SYSTEM MANUAL OFF * ITSMS BLACK (COMMON) * Default Power Pack Programming DETAIL A ITS NETWORK BLACK GREEN WH/GR RED TOP LSW2BCD ILS NETWORK BR WH/BR BL WH/BL GN WH/GN SHIELD OR WH/OR NOTES: 1) Up to 8 digital devices (sensors, button stations, etc.) may be linked in parallel. 2) Orange and Brown control input wires are not polarity sensitive. 3) Multiple ITSMS Switches may be wired in parallel. Figure 5: Connecting Power Pack to Sensors and Button Stations 8 Installation: Dimming Power Packs

11 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Using the Programming Remote An IntelliSight Programming Remote must be used to program the Occupancy Sensors. NOTE: The IntelliSight Programming Remote is available in two versions: ITSIR1 and ITSIR2. Both models have the same functionality as described in the following sections. PROGRAMMING MODE To enter Programming Mode: 1. Aim the remote at the Occupancy Sensor and press the PGM/EXIT button. All affected sensors will blink red. 2. You may now select which sensors you would like to program by "lighting" them with the remote laser. Press and Hold the LASER button and allow the beam to "hit" the sensor you want to select. Once the signal is received, the sensor will illuminate blue and is ready to receive commands. To change the sensor parameters, first select the field which you would like to change. Programming fields include: Mode, Time, Relays, Sensitivity, and Photocell Sensitivity. The following sections will explain each mode. NOTE: After entering the Programming Mode and before tapping any A-H buttons, each relay can be individually controlled by tapping buttons 1-8. Each tap will toggle the relay state (on/off). Tapping button "0" will toggle all relays. This is a helpful tool in testing the installation and determining how the loads are wired. SELECTING DEVICES To select devices for programming (e.g. single occupancy, all occupancy, photocells, or switches), use the Device Select (DSEL) button on the ITSIR1 remote or the FIELD SELECT button on the ITSIR2 remote. Devices may also be individually selected by use of the remote laser. NOTE: The unit will always start in Single Occupancy Mode. To change the selected devices to be programmed: 1. Enter Programming Mode. (Refer to previous section.) 2. Press DSEL button (ITSIR1) or FIELD SELECT button (ITSIR2) to toggle through modes: Blue = Single Occupancy Sensor * Blue/Red = All Occupancy Sensors on network * Red = Switches on network Green = Photocell/Dimming * Additional ITSCS Sensors may be added or removed by using the laser to toggle sensors (blue = included). ITSIR1 PHDA PHDS ITSIR2 Figure 6: IntelliSight Remotes R K P D Using the Programming Remote 9

12 INSTALLATION & Programming: Ceiling Occupancy Sensor Ceiling Occupancy Sensor programming is the same for both single, multiple and all sensors on the network. Programming selections will affect all illuminated sensors. MODE The MODE field allows access to Fixed Time Out or Intelligent Modes, as well as Automatic or Manual On. Factory default is Automatic On\Fixed timing. Intelligent modes continuously monitor occupancy patterns within the space and automatically update the time-out period accordingly. IntelliSight offers three different levels of aggressiveness: Conservative Mode: Automatically adjusts the time-off between 5 to 30 minutes. Normal Mode: Automatically adjust the time-off between 3 and 15 minutes for enhanced energy savings. Aggressive Mode: Automatically adjust the time-off delay between 1 minute and 5 minutes for maximum energy savings. The Occupancy Sensor can be configured to operate in either a Manual On or Automatic On Mode. In Manual On Mode, the lights will only turn on when a designated switch activates the relays. The lights will turn off automatically when vacancy is detected for the time delay period. In the Automatic On Mode, the lights will automatically turn on as soon as occupancy is detected. The lights will turn off when either the designated switch deactivates the relay or automatically when vacancy is detected for the time delay To change the mode of the sensor: 1. Enter Programming Mode (refer to page 9). 2. Press DSEL button (ITSIR1) or FIELD SELECT button (ITSIR2) until the sensor illuminates blue. All devices may be selected by pressing the button again (sensor will illuminate blue/red and all other sensors on the network will illuminate blue). 3. Press MODE button. 4. Select intelligence level: Button 1 Aggressive Intelligence Button 2 Normal Intelligence Button 3 Conservative Intelligence Button 4 Fixed Timing * Factory Default 5. Select activation mode: Button 5 Manual ON Button 6 Automatic ON * Factory Default Button 7 Factory Default Manual ON * Sets all ITSCS parameters to Factory Defaults Button 8 Factory Default Automatic ON (Must press and hold either button for 3 seconds) Button 0 Factory Default * Sets Fixed Timing, Automatic ON Exit programming by pressing the PGM/EXIT button or continue with programming by selecting another field. 10 Programming: Ceiling Occupancy Sensor

13 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Programming: Ceiling Occupancy Sensor (continued) TIME The TIME field allows selection of the time-out period after the sensor no longer detects occupancy. Periods may be selected from 1 to 30 minutes. NOTE: Increasing the time delay will lower the possibility of a false Off trigger, but will also lower the energy savings. To change the time of the sensor: Button 1 1 Minute 1. Enter Programming Mode (refer to page 9). Button 2 3 Minutes 2. Press TIME button. Button 3 5 Minutes 3. Select time-out period by pressing the Button 4 10 Minutes appropriate button. Exit programming by pressing the PGM/EXIT button or continue with programming by selecting another field. Button 5 Button 6 Button 7 Button 8 15 Minutes 20 Minutes 25 Minutes 30 Minutes * Factory Default Button 0 Factory Default * 15 Minutes RELAY SELECTION The RELAY SELECTION field allows selection of which channels will react to the occupancy sensor. To change the relay selection of the sensor: 1. Enter Programming Mode (refer to page 9). 2. Press RLYS button. 3. Select the relay or relays to be controlled by the sensor. Any combination of relays may be assigned to the sensor (example: relays 1, 2 3, 5, and 8). Exit programming by pressing the PGM/EXIT button or continue with programming by selecting another field. Button 1 Relay 1 * Factory Default Button 2 Relay 2 * Factory Default Button 3 Relay 3 * Factory Default Button 4 Relay 4 * Factory Default Button 5 Relay 5 * Factory Default Button 6 Relay 6 * Factory Default Button 7 Relay 7 * Factory Default Button 8 Relay 8 * Factory Default Button 0 Factory Default * Selects all relays Programming: Ceiling Occupancy Sensor 11

14 INSTALLATION & Programming: Ceiling Occupancy Sensor (continued) SENSITIVITY Part of the superior performance of the ITSCS/ITSCSHB Occupancy Sensor involves the increased sensitivity of the sensor system. The three settings are Low, Medium, and High. Each application may be slightly different and the preferences of each user might be different. The default setting (Medium) will be adequate for most situations. The settings are described as follows: Low: Lowest level of detection setting - when less detection is required - occupants are close to the sensor or movements within the space are more pronounced. This level may result in the lights falsely turning off when there is low levels of activity. Medium (default): Default setting - medium level of detection to fit most applications. High: Highest level of detection - movements and activity within the space are less pronounced. This level increases the possibility of false triggering (turning the lights on) or keeping them on longer. To change the sensitivity selection of the sensor: Button 1 Low 1. Enter Programming Mode (refer to page 9). Button 2 Medium * Factory Default 2. Press SENS button. Button 3 High 3. Select the desired level of sensitivity. Button 0 Factory Default * Medium Exit programming by pressing the PGM/EXIT button or continue with programming by selecting another field. OCCUPANCY PHOTOCELL SENSITIVITY There is a photo eye (photocell) in the ITSCS/ITSCSHB Occupancy Sensor which can prevent the Occupancy Sensor from automatically turning on the lights if the light level in the room is already higher than a set level. This feature can be enabled or disabled - with the factory default being disabled. The PHOTOCELL SENSITIVITY field allows selection of the internal photocell s sensitivity levels, as well as disable. To change the sensitivity selection of the photocell: 1. Enter Programming Mode (refer to page 9). 2. Press MPHS button (ITSIR1) or the PHON button (ITSIR2). 3. Select the desired level of sensitivity. 4. To let the unit capture the present room s ambient light level, press and hold button 8 for 4 seconds. The unit will turn off the lights, take a snapshot of the current ambient light level, and then turn the lights back on. Button 1 Low Ambient Button 2 Low-Medium Ambient Button 3 Medium-Low Ambient Button 4 Medium Ambient Button 5 Medium-High Ambient Button 6 High-Medium Ambient Button 7 High Ambient Button 8 Disabled/Capture * Factory Default Button 0 Factory Default * Disabled Exit programming by pressing the PGM/EXIT button or continue with programming by selecting another field. 12 Programming: Ceiling Occupancy Sensor

15 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Programming: Ceiling Occupancy Sensor (continued) MISCELLANEOUS The MISC field allows the audible buzzer and/or the entire Occupancy Sensor to be enabled or disabled. To activate/deactivate the audible buzzer or entire occupancy sensor: 1. Enter Programming Mode (refer to page 9). 2. Press MISC button. 3. Select desired parameters: Button 1 Enable Buzzer * Factory Default Button 2 Disable Buzzer Button 3 Enable Status LEDs * When in Normal Mode Button 4 Disable Status LEDs * When in Normal Mode Button 7 Enable Sensor * Factory Default Button 8 Disable Sensor Button 0 Factory Default * Enable Buzzer/Sensor/LEDs SWITCH PROGRAMMING MODE (RELAY PACK INPUTS OR NETWORK-CONNECTED LSW SERIES KEYPADS) The Switch Programming Mode allows a switch contact or push button to be programmed. To select a switch for programming: 1. Enter Programming Mode (refer to page 9). 2. Press DSEL button (ITSIR1) or FIELD SELECT button (ITSIR2) until the sensor illuminates red. 3. Press SW# button. Network connected keypads will blink all buttons. 4. Select desired switch to program: Button 1 Switch 1 Primary Pack, Input 1 (Orange) Button 2 Switch 2 Primary Pack, Input 2 (Brown) Button 3 Switch 3 Reserved Button 4 Switch 4 Reserved Button 5 Switch 5 Secondary Pack, Input 1 (Orange) Button 6 Switch 6 Secondary Pack, Input 2 (Brown) Button 7 Switch 7 Reserved Button 8 Switch 8 Reserved Button 0 Select LSW Button * The LSW keypad button to be programmed must be pressed and held for 3 seconds NOTE: Button 0 is used to select a button/switch on an IntelliSight compatible keypad. Programming: Ceiling Occupancy Sensor 13

16 INSTALLATION & Programming: Ceiling Occupancy Sensor (continued) SWITCH MODE The SWITCH MODE field designates the mode in which the switch will operate. The modes are as follows: Tap Momentary Closure Switch. When the switch is closed, the relays selected by "Relay On Select" are turned ON, and relays selected by "Relay Off Select" are turned OFF. Double Tap (2 Hour Hold) Momentary Closure Switch. SINGLE TAP - Works the same as TAP above. DOUBLE TAP - Works the same as TAP, except that the time-out to ignore occupancy sensor is set to 2 hours. This applies to both ON and OFF. (Two taps within 1 second constitutes a double tap.) Override When the circuit connected to the Input is open, the Pack operates normally. When the circuit is closed, the relays selected by "Relay On Select" are forced ON and the relays selected by "Relay Off Select" are forced OFF. The unselected relays operate normally. This override is not communicated to other Packs, only relays in the Pack that physically has the Input connection active are affected. This mode can be used for Time Clock control of specific relays, Alarm control of specific relays, or Load Shed. Inverted Override Same functionality as Override except that the Input is inverted, i.e. when the circuit is closed, the Pack operates normally. Toggle Momentary Closure Switch. The first time the switch is closed, the relays selected by "Relay On Select" are turned ON, and the relays selected by "Relay Off Select" are turned OFF. The next closure turns the relays selected by "Relay On Select" to OFF, and relays selected by "Relay Off Select" to ON. The next closure repeats the action of the first closure. A single Momentary Closure Switch can be used to perform a Press ON and Press OFF when set to this mode. Dimmer Raise Momentary Closure Switch. SINGLE TAP - Causes the relays selected by "Relay On Select" to turn ON, and the dimmers to Fade Up to the programmed Scene. Relay Pack inputs only (orange/brown). DOUBLE TAP - Causes the relays selected by "Relay On Select" to turn ON, and the dimmer to instantly go to the programmed Scene. Relay Pack inputs only (orange/brown). PRESS and HOLD - Causes all dimmers to Fade Up. Fade stops when released. Relay Pack inputs (orange/brown) and Lyteswitch keypads. 14 Programming: Ceiling Occupancy Sensor

17 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Programming: Ceiling Occupancy Sensor (continued) Dimmer Lower Momentary Closure Switch. SINGLE TAP - Causes the dimmers to Fade down to OFF, and then causes the relays selected by "Relay Off Select" to turn OFF. Relay Pack inputs only (orange/brown). DOUBLE TAP - Causes the relays selected by "Relay Off Select" to turn OFF instantly. Relay Pack inputs only. PRESS and HOLD - Causes all dimmers to fade to off (dimming relays turn off) on all Lyteswitch keypads. To assign a Switch Mode: 1. Select switch to be programmed [refer to "Switch Programming Mode (Relay Pack Inputs or Network-Connected LSW Series Keypads)" on page 13]. 2. Tap SWM button. 3. Use numerical buttons to assign desired function to that switch. Button 1 Tap * Factory Default Button 2 Double Tap Button 3 Override Button 4 Inverted Override Button 5 Toggle Button 6 Dimmer Raise Button 7 Dimmer Lower Button 8 Returns a selected Lyteswitch keypad to its former mode Button 0 Factory Default * Tap NOTE: When a Lyteswitch keypad button is set by buttons 1-7, it turns the entire keypad into an IntelliSight relaycontrolled keypad. RELAY ON SELECT The RELAY ON SELECT field designates which relay circuits will be activated by the switch. To assign relays to a switch: 1. Select switch to be programmed [refer to "Switch Programming Mode (Relay Pack Inputs or Network-Connected LSW Series Keypads)" on page 13]. 2. Press RON button (while in Switch Programming Mode). 3. Using numerical keypad, select relays to be activated by the designated switch. Any combination of relays may be assigned to the switch (example: relays 1, 2 3, 5, and 8). NOTE: Assignment of relays will be that of last programming sequence. Example: Programming a relay to turn off with a switch will remove it from the RELAY ON command line. Refer to "Relay Off Select" on page 16. Button 1 Relay 1 Button 2 Relay 2 Button 3 Relay 3 Button 4 Relay 4 Button 5 Relay 5 Button 6 Relay 6 Button 7 Relay 7 Button 8 Relay 8 Button 0 Release All Relays Programming: Ceiling Occupancy Sensor 15

18 INSTALLATION & Programming: Ceiling Occupancy Sensor (continued) RELAY OFF SELECT The RELAY OFF SELECT field designates which relay circuits will be deactivated by the switch. To assign relays to a switch: 1. Select switch to be programmed [refer to "Switch Programming Mode (Relay Pack Inputs or Network-Connected LSW Series Keypads)" on page 13]. 2. Press ROFF button. 3. Select which relays are to be deactivated by the designated switch. Any combination of relays may be assigned to the switch (example: relays 1, 2 3, 5, and 8). NOTE: Assignment of relays will be that of last programming sequence. Example: Programming a relay to turn on with a switch will remove it from the RELAY OFF command line. Refer to "Relay On Select" on page 15. ASSIGNING A SCENE TO A SWITCH Button 1 Relay 1 Button 2 Relay 2 Button 3 Relay 3 Button 4 Relay 4 Button 5 Relay 5 Button 6 Relay 6 Button 7 Relay 7 Button 8 Relay 8 Button 0 Release All Relays A Scene may be assigned to a switch. (Note that the Scenes only apply to dimmer levels and affects all dimmers in the connected relay packs.) To assign a Scene: 1. Select switch to be programmed [refer to "Switch Programming Mode Button 1 1 (ON) (Relay Pack Inputs or Network-Connected LSW Series Keypads)" on Button 2 2 (A ) page 13]. Button 3 3 (B) 2. Press SCN button. Button 4 4 (C) 3. Assign a Scene to the switch. Button 5 5 (D) Button 6 6 (E) Button 7 7 (F) Button 8 8 (OFF) Button 0 No Scene Assigned 16 Programming: Ceiling Occupancy Sensor

19 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Programming: Ceiling Occupancy Sensor (continued) ADJUSTING SCENE DIMMER LEVELS (ITSPCS & ITSCS UNITS VERSION 2) A Scene s dimmer levels may be set as required. To adjust Scene dimmer level: 1. Enter Programming Mode (refer to page 9). 2. Press DSEL button (ITSIR1) or FIELD SELECT button (ITSIR2) until the sensor illuminates green. 3. Tap DSCN (E) button to select the Dimmer Scenes (refer to page 9 for IntelliSight Programming Remote button layout). 3a. Tap buttons 1-8 to select the following scenes: Button 1 Scene 1 or On Scene (Sets Max Dimmer Levels for Daylight Harvesting) Button 2 Scene 2 or A Scene (Sets Min Dimmer Levels for Daylight Harvesting) Button 3 Scene 3 or B Scene Button 4 Scene 4 or C Scene Button 5 Scene 5 or D Scene Button 6 Scene 6 or E Scene Button 7 Scene 7 or F Scene Button 8 Scene 0 or Off Scene (Dimmers will always be set to Off) Button 0 Factory Default (Scene 1) NOTE: Dimmers will go to their Last Set Scene Levels. 4. Tap F button (ITSIR1) or DIM button (ITSIR2) to select "Raise Dimmer Levels". Tap G button (ITSIR1) or DIM button (ITSIR2) to select "Lower Dimmer Levels." 4a. Press-Hold-Release buttons 1-8 to Raise or Lower the level of the following Dimmers: Button 1 Dimmer 1 (Relay Pack 1 Dimmer 1) Button 2 Dimmer 2 (Relay Pack 2 Dimmer 2) Button 3 Dimmer 3 (Reserved) Button 4 Dimmer 4 (Reserved) Button 5 Dimmer 5 (Relay Pack 2 Dimmer 1) Button 6 Dimmer 6 (Relay Pack 2 Dimmer 2) Button 7 Dimmer 7 (Reserved) Button 8 Dimmer 8 (Reserved) Button 0 Dimmers1-8 (Master Raise/Lower All Dimmers) NOTE: When button is pressed, the selected Dimmer Level starts to Raise or Lower. When the button is released, the dimmer stops. The power pack will link the relay and dimmer together (example: Relay 1 to Dimmer 1). When the Dimmer Level is set to 0 (off), the linked relay will turn off. Programming: Ceiling Occupancy Sensor 17

20 INSTALLATION & Programming: Ceiling Occupancy Sensor (continued) 5. To save the new dimmer levels to a Scene Tap DSCN (E) button again then Press and Hold the desired Scene button for 3 or more seconds: TEST Button 1 Scene 1 or On Scene (Sets Max Dimmer Levels for Daylight Harvesting) Button 2 Scene 2 or A Scene (Sets Min Dimmer Levels for Daylight Harvesting) Button 3 Scene 3 or B Scene Button 4 Scene 4 or C Scene Button 5 Scene 5 or D Scene Button 6 Scene 6 or E Scene Button 7 Scene 7 or F Scene Button 8 Scene 0 or Off Scene (Dimmers will always be set to Off) Button 0 Factory Default (Scene 1) The Test feature allows testing of the system without having to wait extended periods of time for the loads to time out. While in Test Mode, the timer functions at a rate of 1/60th. A 30-minute time-out period would become a 30-second time-out period with a 10 second minimum. To enter Test Mode: 1. Enter Programming Mode (refer to page 9). 2. Press TEST button. All sensors in Test Mode will blink red (Test Mode), blue (motion detected), or green (delaying to relay off). 3. Confirm all sensors, relays and switches are working properly. 4. Press TEST button again to exit Test Mode. NOTE: Alternate between Test Mode and Programming Mode by pressing the TEST button anytime during the process. DISPLAY The Display feature allows the programmer to visually and audibly verify the programmed feature parameters. To enter Display Mode: 1. Enter Programming Mode (refer to page 9). 2. Select the field you wish to verify. 3. Press DISP button. 4. Tap button for each available setting for the chosen field. The sensor will blink red indicating that the setting is not programmed for the sensor, or blue indicating that the setting is programmed to the sensor. 5. Press DISP button again to exit Display Mode. Example: To see the time-out period of a sensor: Press TIME, then DISP. Toggle through the time selections (buttons 1-8) until the sensor blinks blue to indicate the programmed time-out period. 18 Programming: Ceiling Occupancy Sensor

21 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Programming: Ceiling Occupancy Sensor (continued) EXAMPLE SETUP In this example, we will set the sensor for a 10 minute time-out period and assign a 6-button keypad (Figure 7) to the following format: On Scene = All on 100% Scene A = Dimmer 1 = 100% and Dimmer 2 = 75% Scene B = Dimmer 1 = 75% and Dimmer 2 = 50% Scene C = Raise All Dimmers Scene D = Lower All Dimmers Off = All Off ON A B C D OFF During the example, refer to page 9 for IntelliSight Programming Remote button layout. First, set the time-out period with the following sequence: 1. Press PGM button. (The sensor will flash.) Figure 7: LSW6BCD Keypad 2. Using SSEL button (ITSIR1) or LASER button (ITSIR2), select Sensor to program. (Sensor will illuminate blue.) 3. Press Time button. 4. Press TM-10 button to select 10 minutes. Next, assign button functions to each LSW Keypad: 1. Press DSEL button (ITSIR1) or FIELD SELECT button (ITSIR2) until the sensor illuminates red. Program the LSW ON button: 1. Press the SW# button on the ITSIR (all buttons on the LSW will blink). 2. Press and Hold the LSW ON button for 3 seconds to select that button to program (blinking will stop and selected button will light up). 3. On the ITSIR, press the SWM (B) and then the TAP (1) buttons to assign the button to a TAP mode/function. 4. On the ITSIR, press the RON (C) and then buttons 1-8 to assign which relays (1-8) to turn On when the button is tapped. 5. On the ITSIR, press the ROFF (D) and then the DEFAULT (0) button to deselect all remaining relays from turning Off when the selected button is pressed. 6. On the ITSIR, press the SCN (E) and then the 1 button to select Scene 1(ON). Programming: Ceiling Occupancy Sensor 19

22 INSTALLATION & Programming: Ceiling Occupancy Sensor (continued) Program the LSW A button: 1. Press the SW# button on the ITSIR (all buttons on the LSW will blink). 2. Press and Hold the LSW A button for 3 seconds to select that button to program (blinking will stop and selected button will light up). 3. On the ITSIR, press the SWM (B) and then the TAP (1) buttons to assign the button to a TAP mode/function. 4. On the ITSIR, press the RON (C) and then buttons 1-8 to assign which relays (1-8) to turn On when the button is tapped. 5. On the ITSIR, press the ROFF (D) and then the DEFAULT (0) button to deselect all remaining relays from turning Off when the selected button is pressed. 6. On the ITSIR, press the SCN (E) and then the 2 button to select Scene 2(A). Program the LSW B button: 1. Press the SW# button on the ITSIR (all buttons on the LSW will blink). 2. Press and Hold the LSW B button for 3 seconds to select that button to program (blinking will stop and selected button will light up). 3. On the ITSIR, press the SWM (B) and then the TAP (1) buttons to assign the button to a TAP mode/function. 4. On the ITSIR, press the RON (C) and then buttons 1-8 to assign which relays (1-8) to turn On when the button is tapped. 5. On the ITSIR, press the ROFF (D) and then the DEFAULT (0) button to deselect all remaining relays from turning Off when the selected button is pressed. 6. On the ITSIR, press the SCN (E) and then the 3 button to select Scene 3(B). Program the LSW C button for Raise: 1. Press the SW# button on the ITSIR (all buttons on the LSW will blink). 2. Press and Hold the LSW C button for 3 seconds to select that button to program (blinking will stop and selected button will light up). 3. On the ITSIR, press the SWM (B) and then the (6) buttons to assign the button to a RAISE mode/function. Program the LSW D button for Lower: 1. Press the SW# button on the ITSIR (all buttons on the LSW will blink). 2. Press and Hold the LSW D button for 3 seconds to select that button to program (blinking will stop and selected button will light up). 3. On the ITSIR, press the SWM (B) and then the (7) buttons to assign the button to a LOWER mode/function. 20 Programming: Ceiling Occupancy Sensor

23 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Programming: Ceiling Occupancy Sensor (continued) Program the LSW OFF button: 1. Press the SW# button on the ITSIR (all buttons on the LSW will blink). 2. Press and Hold the LSW OFF button for 3 seconds to select that button to program (blinking will stop and selected button will light up). 3. On the ITSIR, press the SWM (B) and then the TAP (1) buttons to assign the button to a TAP mode/function. 4. On the ITSIR, press the RON (D) and then the DEFAULT (0) button to deselect all relays from turning On when the selected button is pressed. 5. On the ITSIR, press the ROFF (C) and then buttons 1-8 to assign which relays (1-8) to turn Off when the button is tapped. 6. On the ITSIR, press the SCN (E) and then the 8 button to select Scene 8(OFF). Assigning Scene Dimmer Levels: 1. Press DSEL button (ITSIR1) or FIELD SELECT button (ITSIR2) until the sensor illuminates green. 2. On the ITSIR, press the DSCN (E) to select Dimmer Scenes, and then the buttons 1-8 to recall the Scenes 1-8 (ON, A-F, OFF). 3. Once a Scene is selected to be adjusted, press either the DIM (F) or the DIM (G) on the ITSIR to enable either Dimmer Raise or Dimmer Lower. 4. On the ITSIR, Press and Hold a Dimmer button (1-8) to either Raise or Lower the selected dimmer. When the button is released the Dimmer will stop. Pressing the MSTR (0) button will Raise and Lower ALL Dimmers. 5. Repeat steps 3 and 4 to adjust the Dimmers for the selected Scene. 6. To save the new Dimmer levels to a Scene, Press the DSCN (E) button on the ITSIR and then Press and Hold the Scene button to be saved for 3 seconds. 7. Repeat steps 2-6 for every Scene that is to be adjusted. Press the EXIT button on the ITSIR to exit the programming. Programming: Ceiling Occupancy Sensor 21

24 INSTALLATION & Manual Configuration: Ceiling Occupancy Sensor There are two programming switches (buttons) on the Ceiling Occupancy Sensor which can be used to Display and Modify the Sensor s Settings. Programming Switch 2, the "Field" Button (turns on the Blue LED when pressed) is used to select the Field you wish to display or modify. Programming Switch 1, the "Setting" Button (turns on the Green LED when pressed) is used to set the value of the selected Field. By using both buttons, the Sensor can be manually configured for most applications. NOTE: Use the IntelliSight Programming Remote for faster, "hands free" programming of all features. Refer to "Using the Programming Remote" on page 9. To enter Manual Programming Mode: 1. Unscrew Lens Cover on Ceiling Sensor to access manual programming buttons. 2. Press and hold the Field Button for 3 seconds. After 3 seconds the Red LED will turn on indicating the unit is in the Manual Programming Mode. Release the button. To exit Manual Programming Mode: There are three ways to exit the Programming Mode. 1. Press and hold the Field Button for 3 seconds. 2. Keep tapping the Field Button until Ceiling Sensor exits Programming Mode. 3. Stop tapping the buttons. The Ceiling Sensor will exit the Programming Mode 1 minute after the last button press. NOTE: Test Mode may be entered by holding the SETTINGS button for 10 seconds. The sensor will automatically exit the Test Mode after 4 minutes. (Sensor must not be in the Programming Mode.) LED Display When in the Programming Mode, the LEDs display the following information: Red LED Always On. Programming Switch 2 (Field) (BLUE LED) Programming Switch 1 (Setting) (GREEN LED) Figure 8: ITSCS Manual Programming Buttons Blue LED Blinks 1 to 6 times to indicate the Field being displayed or set (see Field/Setting Table on next page). Green LED Blinks 1 to 9 times to indicate the present setting of the Field (see Field/Setting Table on next page). 22 Manual Configuration: Ceiling Occupancy Sensor

25 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Manual Configuration: Ceiling Occupancy Sensor (continued) Field/Setting Table: Blue Blinks - Field Green Blinks - Setting 1 - Aggressive Intelligence 1 - Mode 2 - Normal Intelligence 3 - Conservative Intelligence 4- Fixed Timing * 2 - Manual/Automatic 1 - Manual, 2 - Automatic * 3 - Time 1-1 min, 2-3 min, 3-5 min, 4-10 min 5-15 min *, 6-20 min, 7-25 min, 8-30 min 1 - Relay 1, 2 - Relay 2, 3 - Relay 3, 4 - Relay Select 4 - Relay 4, 5 - Relay 5, 6 - Relay 6, 7 - Relay 7, 8 - Relay 8, 9 - All Relays * 5 - Sensitivity 1 - Low, 2 - Medium *, 3 - High 6 - Photocell On Sensitivity 1 - Low,...7 High, 8 - Disabled * * Factory Default To set a Field: 1. After entering the Programming Mode, the Field LED (Blue) will blink one time (Field Set), display the present setting (green blinks), and then repeat the pattern. 2. Each press of the Field Button will select the next Field. 3. Pressing the button after the last field will exit the Programming Mode. 4. Once the Field is selected (proper number of blue blinks), press the Setting Button one or more times to change the Field setting. Verify by observing the number of blinks. 5. Once the Field is selected (proper number of blue blinks), pressing and holding the Setting Button for 3 seconds will set the Factory Default for that Field. NOTES: Each tap of the Setting Button will advance the setting by one. Example: Three taps sets the Field setting to 3 (taps must be less then 2 seconds apart). After 2 or more seconds following the last tap, the Setting Button will reset back to 1 with the next tap. Example: Three taps, delay of 2 or more seconds, and then two taps will set the Field setting to 2. To set Factory Default for All Fields: When entering the Programming Mode, instead of holding the Field Button for 3 seconds, hold it for 10 seconds. After 10 seconds the Sensor will reset all Fields back to Factory Default, buzz long, and exit the Programming Mode. Manual Configuration: Ceiling Occupancy Sensor 23

26 INSTALLATION & Power Pack Primary/Secondary Mode Selection The Dimming Power Pack can be used as either a primary or secondary power pack allowing for up to 8 individually controlled relay channels and 4 individually controlled dimmer channels. If a Power Pack has a yellow wire, it is used to set the pack as a Primary (relays 1-4) when left unconnected, or as a Secondary (relays 5-8) when connected to ground (black). Primary Mode (DEFAULT) Yellow Yellow Black Primary Secondary In this Mode the Relays are numbered 1-4 and Dimmers, if present, are numbered 1, 2 and the Switch Inputs are numbered 1, 2. The Primary sets the state of all relays, including in the Secondary pack to the last state upon power-up. During power-up, it also pings the network for 1 minute to test communications. Secondary Mode In this Mode the Relays are numbered 5-8 and Dimmers, if present, are numbered 5, 6 and the Switch Inputs are numbered 5, 6. Mimic Primary Mode In this Mode the Relays are numbered 1-4 and Dimmers, if present, are numbered 1, 2 and the Switch Inputs are numbered 1, 2. The power pack only listens to the network and Mimics the functionality of the Primary Pack. Mimic Secondary Mode In this Mode the Relays are numbered 5-8 and Dimmers, if present, are numbered 5, 6 and the Switch Inputs are numbered 5, 6. The power pack only listens to the network and Mimics the functionality of the Secondary Pack. To set the power pack mode: NOTE: It is recommended that an ITSMS Momentary switch be used to for power pack mode programming. 1. Enter Programming Mode (refer to page 9). 2. Select switch to be programmed (refer to "Switch Programming Mode (Relay Pack Inputs or Network-Connected LSW Series Keypads)" on page 13). 3. Select "Primary" or "Secondary" Mode: Primary (default) Tap (ON) 3 times Tap (OFF) once Secondary Tap (ON) 3 times Tap (OFF) twice NOTE: Once you start a tap sequence on an input, you have 5 seconds to complete it. After the first 3-tap sequence, you have 10 seconds to complete the full sequence. 4. If necessary, select "Mimic On" or "Mimic Off": Mimic Off (Default) Tap (OFF) 3 times Tap (ON) once Mimic On Tap (OFF) 3 times Tap (ON) twice 24 Power Pack Primary/Secondary Mode Selection

27 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Power Pack Mode Selection (continued) The Green LED will display the current mode: OFF quick flash ON once per second OFF quick flash ON twice per second ON quick flash OFF once per second ON quick flash OFF twice per second Primary Mode Secondary Mode Primary Mimic Mode Secondary Mimic Mode Troubleshooting Guide Symptom Cause Correction Lights do not come on either manually or automatically. Lights do not come on automatically. Lights are On all the time. Remote does not turn on lights. Occupancy outside the desired space triggers sensor. No audible warnings before lights turn off. Lights turn off, even though room is occupied. Lights remain on too long when room is unoccupied. User delay will not allow adjustment outside a certain range of Time Delay settings. Sensor is not reacting to programming IR remote control. Lamp(s) are burned out or missing. Circuit breaker is off. Wire connections are faulty. Sensor is in Manual Mode. Sensor sensitivity setting not appropriate. Wire connections are faulty. Shorted or damaged device. Wire connections are faulty. Non-ideal placement or no mask is being used. Sensor sensitivity setting not appropriate. Audible warning is disabled. Insufficient movement, frequency or amount. Time Off delay too long. Logic/Timer Mode enabled. Batteries are expired in IR remote. Replace lamp(s) in fixture(s). Turn on circuit breaker. Recheck all wire connections. Important! Turn off circuit breaker before servicing. Use Manual Mode if local or installation requires. Reconfigure sensor to Automatic Mode, if allowed. Lower sensor sensitivity. Recheck all wire connections. IMPORTANT! Turn off circuit breaker before servicing. Replace sensor with new unit. Recheck all wire connections. IMPORTANT! Turn off circuit breaker before servicing. Use proper masking to mask unwanted areas. Lower sensitivity setting. Enable audible warning tones. Increase Time Out or increase sensor sensitivity. Decrease Time Off delay or set Logic/Timer Mode accordingly. Verify Logic/Timer Mode and adjust sensor accordingly. Replace batteries. Troubleshooting Guide 25

28 INSTALLATION & Specifications Dimming Power Pack Electrical / Operating Specifications: AC Input Voltage: Dual Voltage Input (120V ~ 277 VAC, 60 Hz) 120 VAC, 60 Hz (108 to 132 VAC) 277 VAC, 60 Hz (250 to 305 VAC) Loads: Model Volts Tungsten Ballast ITSRPHDF2U * 120 Not Applicable 20A (2400VA) 277 Not Applicable 8.66A (2400VA) ITSRPHDF4U * A (1800VA) 15A (1800VA) 277 Not Applicable 6A (1800VA) ITSRPFAM2U * 120 Not Applicable 20A (2400VA) 277 Not Applicable 8.66A (2400VA) ITSRPFAM4U * A (1800VA) 15A (1800VA) 277 Not Applicable 6A (1800VA) * = per relay / channel (20A max/pack) Load Capacity: 50 per channel Isolation: 1600 VAC, 60 Hz DC Output Voltage: +12 VDC, Unregulated DC Output Current: 150 ma (max.) Control Input: Isolated, 12-24V (AC or DC), 2.5 5mA Operating Temp: 0 to 50 degrees C Dimensions: 4" (H) x 4" (W) x 2.25" (D) - ITSRPHDF2U / ITSRPFAM2U 4-11/16" (H) x 4-11/16" (W) x 2.25" (D) - ITSRPHDF4U / ITSRPFAM4U Compliance: UL and cul Listed Dimming Power Pack Dimensions: ITSRPxxx4U Shown X 2 1/4" SIDE VIEW X = 4" (ITSRPxxx2U) 4-11/16" (ITSRPxxx4U) TOP VIEW NOTE: Control inputs are optically isolated and may be programmed to accept a variety of inputs, 12 to 24V AC or DC. 26 Specifications

29 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Notes Notes 27

30 INSTALLATION & Notes 28 Notes

31 INSTALLATION & INTELLISIGHT OCCUPANCY SENSOR & DIMMING POWER PACKS Notes Notes 29

32 INSTALLATION & THREE YEAR LIMITED WARRANTY The The Lightolier Philips Controls Controls product, product, when when properly properly installed installed and and under under normal normal conditions conditions of use of use (without (without overload, overload, abuse abuse or or alteration), alteration), is is warranted warranted to to you, you, the the original original user, user, for for a period period of of three three years form from the the date of of original retail purchase, to be be free free from from defects defects in in materials materials and and workmanship. workmanship. If If during during the the warranty warranty period period you you believe believe the the purchased product or any any part part thereof thereof has has such such a a defect, defect, you you must must return return the the product product (or (or part) part) at at your your cost cost during during such such period, period, with with proof proof of of purchase (or if installed by a third-party a written explanation of installation transaction with proof of date), to Lightolier purchase (or if installed by a third-party a written explanation of installation transaction with proof of date), to Philips Controls, 2828 Trade Center Dr. Ste. 130B, Carrollton, TX 75007, for repair or replacement (or to an authorized Lightolier Controls, 2828 Trade Center Dr. Ste. 130B, Carrollton, TX 75007, for repair or replacement (or to an authorized Philips Controls supplier which agrees in advance to handle the return and replacement by factory authorization). If the product Controls supplier which agrees in advance to handle the return and replacement by factory authorization). If the product or part is found by Lightolier Controls to have been defective in material or workmanship it will be repaired or replaced (as or deemed part is found necessary by Philips by Lightolier Controls Controls), to have been and defective the replacement in material will or workmanship be returned to it you will free be repaired of charge. or replaced The original (as user deemed is solely necessary responsible by Philips for Controls), any costs and associated the replacement with removal will be and returned re-installation to you free of of the charge. product The and original shipping user to is Lightolier solely responsible Controls or for its any authorized costs associated supplier. with removal and re-installation of the product and shipping to Philips Controls or its authorized supplier. LIGHTOLIER CONTROLS LIMITS THE DURATION OF THE IMPLIED WARRANTY OF MERCHANTABILITY WITH RESPECT TO THE PHILIPS PRODUCT CONTROLS TO THE LIMITS LIMITED THE WARRANTY DURATION PERIOD OF THE IMPLIED SET FORTH WARRANTY ABOVE, AND OF MERCHANTABILITY OTHERWISE DISCLAIMS WITH ALL RESPECT IMPLIED TO WARRANTIES THE PRODUCT WITH TO RESPECT THE LIMITED TO THE WARRANTY PRODUCT PERIOD AND ITS SET PARTS. FORTH Some ABOVE, states AND disallow OTHERWISE certain DISCLAIMS limitations ALL on IMPLIED implied warranties WARRANTIES so you WITH should RESPECT consult TO your THE state PRODUCT law if you AND have ITS a question PARTS. Some regarding states this disallow limitation certain and limitations disclaimer. on implied Lightolier warranties Controls so you disclaims should consult any and your all state liability law for if you incidental, have a questions consequential, regarding special this or limitation indirect and damage disclaimer. arising Philips out of any Controls claimed disclaims breach of any warranty and all liability or otherwise. for incidental, However, consequential, some states do special not allow or indirect exclusion damage or limitation arising out of such of any damages, claimed so breach this disclaimer of warranty may or not otherwise. apply to you. However, some states do not allow exclusion or limitation of such damages, so this disclaimer may not apply to you. The remedy provided in this Limited Warranty for defective products is the user s sole and exclusive remedy, subject to your The state remedy law. provided Further, this in the Warranty Limited gives Warranty the user for specific defective legal products rights, is and the the user s sole may and also exclusive have other remedy, rights which subject may to vary your from state state law. to Further, state. this Warranty gives the user specific legal rights, and the user may also have other rights which If may you vary believe from warranty state to state. claim is warranted, you may contact your nearest authorized Lightolier Controls supplier. If one does not exist in your area, please contact Lightolier Controls Customer Service at the above address (or at If you believe warranty claim is warranted, you may contact your nearest authorized Philips Controls supplier. If one does 2731), or please visit us at not exist in your area, please contact Philips Controls Customer Service at the above address (or at ), or please visit us at This product may be covered by one or more of the following U.S. Patents: #4,413,211; 4,430,576; 4,465,956; 4,733,138; 4,792,731; 4,880,950; 4,988,840; 4,992,709; 5,004,969; 5,004,969; 5,128,654; 5,153,816; 5,189,259; 5,194,858; 5,239,255; 5,239,255; 5,371,439; 5,371,444; 5,506,480; 5,636,111; 5,642,104; 5,646,490; 5,814,550; 5,821,704; 5,920,156; 5,930,126; Des. #307,578; 333,124; 435,203; 440,207; License # ; 5,004,969; 5,239,255; and corresponding foreign patents. Other Utility, Design and Foreign Patents Pending. We reserve the right to change details of design, materials and finish in any way that will not alter the installed appearance or reduce function performance. Specifications are subject to change without notice. Lightolier Controls 2828 Trade Center Dr. Ste. 130B Carrollton, TX Lightolier Controls is a Philips group Controls brand brand Technical/Sales assistance: Made Made in U.S.A. in U.S.A Lightolier Philips Controls Controls P/N P/N B

INSTALLATION AND OPERATIONS MANUAL FOR MODELS: ITSDU / ITSHDFU / ITSEBU

INSTALLATION AND OPERATIONS MANUAL FOR MODELS: ITSDU / ITSHDFU / ITSEBU ISTALLATIO AD OPERATIOS MAUAL FOR MODELS: ITSDU / ITSHDFU / ITSEBU THREE YEAR LIMITED WARRATY The Lightolier Controls product, when properly installed and under normal conditions of use (without overload,

More information

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS IMPORTANT SAFEFGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. THESE INCLUDE: READ AND FOLLOW ALL SAFETY INSTRUCTIONS

More information

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION

More information

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION

More information

DRC12FR DRC12FR347. Dynalite. Install Guide

DRC12FR DRC12FR347. Dynalite. Install Guide DRC12FR DRC12FR347 Dynalite Install Guide Contents 1 Important Safety Information 2 Overview 3 Installation Installations Overview Tools List Location and Clearances Mounting the Cabinet Connecting Line

More information

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Instruction Bulletin 63249-420-418A1 02/2014 Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Commercial Grade with Ground SLSPWD1277C Retain for Future Use INTRODUCTION The Passive Infrared

More information

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature DT-300 v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...25

More information

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED Vapor Tight Linear Fixture General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC echoflex Powered by ETC Complete Room Controller F series ERDRC-FC This guide covers the F series of the Complete Room Controller, model number ERDRC-FCU equipped with a 902 MHz radio. The box contents

More information

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS! MODEL EPC-D-F-ATS INSTALLATI INSTRUCTIS! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIS

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC echoflex Powered by ETC ER1S-FC Slim Line Dimming Controller F series This guide covers the F series of the Complete Room Controller, model number ER1S-FCU equipped with a 902 MHz radio. The box contents

More information

MaxLite LED Round Pendant Highbay Series

MaxLite LED Round Pendant Highbay Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Ultrasonic Wall Switch Occupancy Sensor Single Circuit Instruction Bulletin 63249-420-414A1 02/2014 Ultrasonic Wall Switch Occupancy Sensor Single Circuit Commercial Grade with Ground, Single and Multi Location Switching SLSUWS1277C and SLSUWS3277C Retain

More information

600 Watt Dimmer Install Guide

600 Watt Dimmer Install Guide 600 Watt Dimmer Install Guide ER6CD This guide covers all models of the ER6CD lighting controller. The box contents includes the controller with lock nut and installation guide. Overview The ER6CD controller

More information

Installation Instructions

Installation Instructions Specifications PW-100 PW-200 PW-100/PW-100-347/PW-200/PW-200-347 v3 Passive Infrared Wall Switch Occupancy Sensor PW-100-347 PW-200-347 Voltages: PW-100 & PW-200................ 120/277VAC, 50/60Hz PW-100-347

More information

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MaxLite LED VAPOR TIGHT LINEAR FIXTURES A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 1 800 681-9590 F. 418 681-7393 E. info@cristalcontrols.com cristalcontrols.com TM Index Quick Selection...3-4 Which Technology to use...4 Retrofit

More information

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions Ceiling-Mounted Motion Detector 752/CD, 752/CP, 752/CU and 752/Cx180 Installation Instructions Contents 1.0 Description...3 1.1 Contents of the Box...3 2.0 Safety...4 3.0 Coverage Patterns...4 3.1 PIR

More information

Installation Instructions

Installation Instructions DT-300 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features Specifications Voltage................18-28VDC/VAC, half wave rectified AC Current Consumption...............................43mA

More information

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70 PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden

More information

BACKUP BATTERY INSTALLATION INSTRUCTIONS

BACKUP BATTERY INSTALLATION INSTRUCTIONS www.tiltlights.com BACKUP INSTRUCTIONS A Lauren International Company www.laurenillumination.com 855 440 8458 LdPE7-2014 SELf-TESTINg EmERgENCY LEd driver RATINGS: Input: 100-277 VAC 50 or 60 Hz Output:

More information

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE Please note: The TH106 comes factory set in baseboard mode (even though the Honeywell Owner s Guide incorrectly reflects a factory setting of fan mode).

More information

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit

More information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..

More information

Installation Instructions

Installation Instructions Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................

More information

Turin LED Ceiling Fan

Turin LED Ceiling Fan Turin LED Ceiling Fan model no. no. 052-6972-6 Instruction Manual Toll-free: -866-827-4985 IMPORTANT: Please read and understand this manual before any assembly. Before beginning assembly of product, make

More information

DOLKPL1KB DOLKPS1KB DOLKSF1KB

DOLKPL1KB DOLKPS1KB DOLKSF1KB DOLKPL1KB DOLKPS1KB DOLKSF1KB USER MANUAL INSTRUCTIONAL VIDEO 1] Connection Terminals 2] Basic Wiring Example 3] Quick Start Guide 4] Programming Guide 5] Specifications 1 Connection Terminals The DOLKPS1KB/DOLKPS1KB/DOLKSF1KB

More information

Installation Instructions

Installation Instructions Overview The SIMPLY5 Sensor Connector is used to provide an input for low voltage occupancy sensors and photocells. Use the S5SC with SIMPLY5-compatible lighting fixtures and control devices for fully

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL Model TME- * * Balance of model number is determined by customer specifi ed limits and Setbacks. AUTOMATIC SETBACK THERMOSTAT LIGHT SENSING OR CONTACT CLOSURE FOR LOW VOLTAGE

More information

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications LOSBAY800 BAY SENSOR Installation Manual LOSBAY800 Specifications Coverage Area: 50-60 diameter @ 40 height Time Delay: 30 seconds to 30 minutes Photocell Adjustment: 3.7 fc to185 fc (40-2000 Lux) Operating

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12 PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting

More information

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS

More information

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC

More information

Model #: RC3 Model #: RC3D Model #: RC3DE SAFETY INSTRUCTIONS

Model #: RC3 Model #: RC3D Model #: RC3DE SAFETY INSTRUCTIONS gate Installation Instructions l #: RC l #: RCD l #: RCDE l #: RC-PL l #: RCD-PL l #: RCDE-PL l #: RCD-PL-CP l #: RCDE-PL-CP l #: RC-PL-N l #: RCD-PL-N l #: RCDE-PL-N l #: RCD-PL-N-CP l #: RCDE-PL-N-CP

More information

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS! MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATI! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIS

More information

WARNING Important Safety Information

WARNING Important Safety Information Builder Series Non-Programmable Thermostats MODEL 1000 MODEL 0 1 2 3 4 Single Stage Heat / Cool Conventional and Heat Pump Multi-Stage 2 Heat / 1 Cool Conventional and Heat Pump Before Installing, Programming

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 7,891,572 INSTALLATION INSTRUCTIONS and OPERATING MANUAL Saves Fuel Features

More information

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode) INSTALLATION INSTRUCTIONS DUAL AIR INTAKE 2650-1847-77 USE TEFLON SEALING TAPE OR SEALING COMPOUND ON PIPE THREADS OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Pro Control Output

More information

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. Section 1 General Description The is a high mount microprocessor controlled active infrared presence detector for all types

More information

VX SERIES Wireless Thermostat with Occupancy Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat

More information

ELECTRIC FIREPLACE OWNER S MANUAL

ELECTRIC FIREPLACE OWNER S MANUAL ELECTRIC FIREPLACE OWNER S MANUAL MODELS EL1346C 4001358 WARNING: If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc. USER S MANUAL ALARM HI F2 COOL / HEAT ALARM LO DIFF on off PERIOD TIMER L IMIT reduc. 9 per day 88 ADJUST Varifan + Although the manufacturer has made every effort to ensure the accuracy of the information

More information

MaxLite LED MICRO-T PANEL

MaxLite LED MICRO-T PANEL ` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all

More information

Product Specifications Dialog Room Controller* (*patent pending)

Product Specifications Dialog Room Controller* (*patent pending) 1 Product Specifications Dialog Room Controller* (*patent pending) 1. GENERAL 1.1. OVERVIEW 1.1.1. Provide a complete stand-alone, decentralized, low voltage, digital lighting control system for classrooms,

More information

ESRB and ESRN Installation & Safety Instructions

ESRB and ESRN Installation & Safety Instructions B1784 ESRB and ESRN Installation & Safety Instructions IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW

More information

IN2 Lighting Control Devices

IN2 Lighting Control Devices Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Lighting Control Devices Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Infrared Ceiling Mount Sensor

Infrared Ceiling Mount Sensor Infrared Ceiling Mount Sensor LOS-CI Series LOS-CI- 0.0.06 The LOS-CI Series ceiling-mount passive infrared sensors can integrate into Lutron systems or function as standalone controls using a Lutron power

More information

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm). Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)

More information

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

be liable for any other loss or damage, whether direct, indirect, incidental or consequential. Integrated HydroStat 3200-Plus for Slant Fin Boilers Part No. 48-3200-03 and 48-3200-04 120 VAC Input / 24 VAC Burner Circuit PATENT S. 8.391,708; 7,891,572; 8,844,834; Others Pending INSTALLATION INSTRUCTIONS

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

Installation Instructions

Installation Instructions ELCU-200 Control Unit Circle CUT-OUT R8.5 mm Push to Test Specifications Cir.# Remote Activation Voltages... 120/277VAC 50/60Hz Max Load Requirements Ballast... 20A @120/277VAC Incandescent... 10A @120VAC

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106C Certified ISO 9001 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1075 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS 3 Occupied, 1 Unoccupied Override capable 3 speed fan control Auto 2-pipe changeover when used with accessory

More information

Alarm Tone Generator Model AG17

Alarm Tone Generator Model AG17 Alarm Tone Generator Installation & Operation P005089 Rev. C 150930 9/30/2015 12:25 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...

More information

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor Section 1 General Description The is a microwave motion sensor for activating automatic industrial doors. Features include a speed selectable switch that makes the unit capable of detecting pedestrians

More information

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters TPI Corporation P.O. Box 4973 Johnson City, TN 37601 www.tpicorp.com OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING RESIDENCES IMPORTANT SAFETY INFORMATION INSIDE possible

More information

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS NOTE: Set up for this sensor should be performed by an AAADM-certified installer. Section 1 General Description The DHR3 is a combination microwave/infrared sensor providing both motion detection and presence

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5211 2-Stage Heat Pump Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat Pump Systems Large Display With Backlight Selectable

More information

MaxLite LED High Bay Fixtures

MaxLite LED High Bay Fixtures General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 3006 Auto Changeover 7-Day Programmable Hardwired Programmable Electronic Thermostat 7-Day Programmable Single Stage Heat Pump/Non-Heat Pump Systems Backlit Display Single Stage Heat/Cool Systems Field

More information

Active Infrared Multi Beam Sensors

Active Infrared Multi Beam Sensors Active Infrared Multi Beam Sensors D Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP

More information

DS-5C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

DS-5C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS CAUTION: Read all instructions carefully before installation. Save this Installation Manual for future reference. GENERAL SAFETY INSTRUCTIONS 1. THIS UNIT SHOULD BE INSTALLED, OPENED, AND REPAIRED BY QUALIFIED

More information

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM DIVISION 26 ELECTRICAL SECTION 26 09 26 PART 1 GENERAL 1.01 DESCRIPTION A. The intent of this set of specifications is to provide a complete, functional, intelligent, lowvoltage lighting control system

More information

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation Refrigeration Innovation Thermo Simple 2 Manual Refrigeration Innovation, LLC. 1250 Harter Avenue, Suite E Woodland, CA 95776 Ph: 530.666.3020 Fx: 530.666.3027 Refrigeration Innovation, LLC. 1250 Harter

More information

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor

More information

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.) Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

52 CEILING FAN. Owner s Manual Models #50336, 50337

52 CEILING FAN. Owner s Manual Models #50336, 50337 52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.

More information

7-Day. Digital Thermostat. residential. & 2-cool

7-Day. Digital Thermostat. residential. & 2-cool Digital Thermostat residential THERMOSTAT T1100FS 7-Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 Heat & 2 Cool Stages 7-Day Programmable 4 Settings/Day Auto Changeover 5 minute Built-In

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

Projection Alarm Clock USER GUIDE

Projection Alarm Clock USER GUIDE Projection Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME, Warnings

More information

Active Infrared Multi Beam Sensors. R Series

Active Infrared Multi Beam Sensors. R Series Active Infrared Multi Beam Sensors R Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP

More information

Protocol Station Remote Alarm

Protocol Station Remote Alarm ADI 5135-C Certified ISO 9001 Protocol Station Remote Alarm 529 5135-01-120 529 5135-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR 5/9/18 Procurement Towson University 8000 York Road Towson, MD 21252-0001 t. 410 704-2171 f. 410 704-8233 Ladies and Gentlemen:

More information

120 VAC SYSTEM CONTROL KIT Model: CK-63

120 VAC SYSTEM CONTROL KIT Model: CK-63 120 VAC SYSTEM CONTROL KIT Model: CK-63 Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls. The CK-63 control has the ability to operate

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL temperature / static pressure DIFF Opn Clo ALARM HI F2 DELAY ALARM LO OPEN DELAY CLOSE ADJUST Varifan + CPS-1 CPS-1 Although the manufacturer has made every

More information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING MODEL Premier Series 3000 USER MANUAL Non-Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

Description of the vacuum

Description of the vacuum Description of the vacuum by RSBH-O, RSBH-C, RSBH-SB RSBHP-O & RSBHP-C Owner s Manual Contents IMPORTANT SAFETY INSTRUCTIONS... 3 Safety Features... 4 Polarization Instructions... 4 Benefits... 5 Description

More information

Universal Fan and Light Remote Control

Universal Fan and Light Remote Control Universal Fan and Light Remote Control Hand-Held Remote and Wall Cradle Owner s Guide and Installation Manual English Form# 41316-01 20100930 2010 Hunter Fan Co. 1 Welcome Table of Contents Read and Save

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications Premier Series Non-Programmable Thermostats MODEL 3000 MODEL 3200 1 2 3 4 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information

More information

Section 1 General Description

Section 1 General Description CX-33 Advanced Logic Relay Installation Instructions Firmware Ver. 2.5 Section 1 General Description The CX-33 is the latest generation multi-purpose logic control. It is designed to be versatile yet user

More information

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 160 854 Roanoke 48 in Ceiling Fan Owner s Manual Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 48 Roanoke Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product

More information

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS Engineered Products Company s LED RetroFit Conversion Kits convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and attractive design

More information

2800 Series Control Units

2800 Series Control Units Occupant Copy 800 Series Control Units CAUTION! To avoid overheating and possible damage to equipment, do not use the GRAFIK Eye 800 Series Control Unit to control a receptacle, a motor-operated appliance,

More information