1 I P Explosion Proof Starter 1Ø & 3Ø, 115~600VAC, 1 75HP START/STOP AND RESET PUSHBUTTONS ELECTRONIC MOTOR PROTECTION Tough Starters for Tough Environments Ready to Install, Completely Wired and Assembled Door mounted Start, Stop & Reset pushbuttons/pc Enclosure door features durable NEMA 4 gasket All starters include pre-drilled conduit holes Fast turn around time* 5-Year contactor warranty Flexible Control Power Transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection no fuses required Standard 120VAC secondary control Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset Combination Versions Include Disconnect Wide range electronic overload eliminates sizing call backs. Motor circuit protection disconnect provides short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required save time and money Lockable cast aluminum breaker handle for safety Customize to Meet Your Application* High quality components complete a UL listed starter package. 2 or 3 position selector switches Long life LED pilot lights Additional conduit entries Emergency Stop pushbutton Installed Breather & Drain Lockable cast aluminum disconnect handle is safe and secure.

2 Specifications Starter Type IXP - Explosion Proof Starter Across the line or Full Voltage Non-Reversing NEMA 7 Enclosure User Interface Start/Stop Pushbuttons OR Hand/Off/Auto Mechanical Enclosure Type NEMA 7 Environmental Ambient Operating Temp -5 to 140 F (-20 to 60 C) Ambient Storage Temp -5 to 185 F (-20 to 85 C) Relative Humidity 5% to 95% non-condensing (NEMA 1) Motor Protection Adjustment/Description Overload Type Electronic; I 2 t Thermal Trip Curve Current Setting Range A, 1-5A, A, 8-40A, 16-80A Trip Class Class 1-30 Reset Manual Phase Unbalanced Trip within 3 70% unbalance Phase Loss Trip within 3 seconds Stall Condition Trip within 3 170% FLA Ordering and Sizing Information NEMA 7 EXPLOSION PROOF ENCLOSURE COMBINATION MAGNETIC STARTERS - Electronic Overload HP Three Phase 200V 230V 460V 600V* 3/4 3/4 NEMA SIZE IXP w/ Start/Stop IXP7-9/J-G1.6-5 IXP w/ HOA IXP7-9/J-G1.6-5H 1/2 1/ IXP7-9/J-G2.5-5 IXP7-9/J-G2.5-5H 3/4 3/ IXP7-9/J-G4-5 IXP7-9/J-G4-5H IXP7-9/J-G6-5 IXP7-9/J-G6-5H IXP7-9/J-G8-22 IXP7-9/J-G8-22H IXP7-18/J-G10-22 IXP7-18/J-G10-22H IXP7-18/J-G13-22 IXP7-18/J-G13-22H IXP7-18/J-G17-22 IXP7-18/J-G17-22H IXP7-32/J-G22-40 IXP7-32/J-G22-40H IXP7-32/J-G26-40 IXP7-32/J-G26-40H IXP7-32/J-G32-40 IXP7-32/J-G32-40H IXP7-50/J-G40-80 IXP7-50/J-G40-80H IXP7-50/J-G50-80 IXP7-50/J-G50-80H IXP7-85/J-G63-80 IXP7-85/J-G63-80H IXP7-85/J-G75-80 IXP7-85/J-G75-80H IXP7-85/J-G90-80 IXP7-85/J-G90-80H

3 NEMA 7 EXPLOSION PROOF ENCLOSURE STANDARD MAGNETIC STARTERS - Electronic Overload HP Three Phase 200V 230V 460V 600V* NEMA SIZE IXP Part Number IXP w/ HOA IXP7-9/J-5 IXP7-9/J-5H IXP7-18/J-22 IXP7-18/J-22H IXP7-32/J-40 IXP7-32/J-40H IXP7-50/J-80 IXP7-50/J-80H IXP7-85/J-80 IXP7-85/J-80H OPTIONS Part Number IXP-XHPP IXP-XHS1 IXP-XLS IXP-XDB IXP-XDB2 IXP-XLP Description E-Stop Red Pushbutton, 1N.C. 2-Position Selector Switch, 1N.O. & 1N.C. Pilot Light, 120VAC Breather & Drain Installed Bottom* Breather & Drain Installed* Push-To Test Light, 120VAC 1N.O. & 1N.C. IXP-NP Nameplate, Specify Text (1 x 4 inch) IXP-ENT Additional Conduit Entry* Standard (no disconnect) Dimensions Part numbers: (IXP7-18/J-5) - (IXP7-85/J-80)

4 Combination (with disconnect) Dimensions Part Numbers: (IXP7-18/J-G1.6-5) - (IXP7-32/J-G32-40) A Combination (with disconnect) Dimensions Part Numbers: (IXP7-50/J-G40-80) - (IXP7-85/J-G90-80)

5 Wiring Schematic Standard schematic shown, actual schematic may vary.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018 SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

TOWER IQ Stand Alone or Building Automation Controlled Options Scalable to meet any application Energy Saving VFDs

TOWER IQ Stand Alone or Building Automation Controlled Options Scalable to meet any application Energy Saving VFDs TOWER IQ Stand Alone or Building Automation Controlled Options Scalable to meet any application Energy Saving VFDs All-Inclusive Single Point Cooling Tower Control INTEGRATES WITH AN EXISTING AUTOMATION

More information

Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase

Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase Starters and Contactors Definite Purpose Contactors Standard, Open Type Ampere Rating Coil Voltage No of Pole Voltage CR353AB2AA1GE 25 110-120 @ 50/60 Hz 2 600 CR353AC3AH1GE 30 24 VAC @ 50/60 Hz 3 600

More information

SIMPLEX WEATHERPROOF CONTROL PANELS

SIMPLEX WEATHERPROOF CONTROL PANELS TECHNICAL BROCHURE BCP3 R10 FEATURES Rugged, NEMA 4X construction withstands even the most severe weather con ditions and prevents corrosion. Solid-state control board displays float status for ease of

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2 The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:

More information

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

Mission Critical. Fuel Supply Systems

Mission Critical. Fuel Supply Systems Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes ac,

More information

a thriving company in a dynamic industry

a thriving company in a dynamic industry a thriving company in a dynamic industry At Sprecher + Schuh, helping our customers succeed is what we do best with industrial control and informative solutions designed to give our customers a competitive

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS

APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS CONTINUOUS HEAVY DUTY CYCLING OF MOTORS MINING PETROCHEMICAL PULP & PAPER ROCK CRUSHING OIL PUMPING WATER/WASTEWATER TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS. NEMA VACUUM CONTACTORS NEMA VACUUM OPEN

More information

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. CUSTOM CONFIGURED PRODUCTS READY FOR SHIPMENT IN ONE TO TEN BUSINESS DAYS. Appleton s Quick Response Program places select power and control products

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

EJB Custom-Built Control Panels

EJB Custom-Built Control Panels EJB Custom-Built Control Panels Cl. I, Div. 1 & 2, Groups B*, C, D Cl. I, Zones 1 & 2 Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III UL and cul approved Ex d IIB + H2 T6 Certified to

More information

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. NAME OF TENDER: CONSTRUCT, DELIVER AND COMMISSION 3 (THREE) LIFT STATION ELECTRICAL LOCATION OF WORK: 3 Separate work sites in

More information

Fluid Cooler Fan and Pump control panel

Fluid Cooler Fan and Pump control panel user manual Fluid Cooler Fan and Pump control panel INSTALLATION - OPERATION - MAINTENANCE Z02819_A M03-171B ISSUED 07/2014 0/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR OR SERVICING THIS

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

METRO SEWER DISTRCT (MSD), CINCINNATI, OHIO DETAILED PROVISIONS FOR ELECTRICAL PUMP CONTROL PANELS FOR PUMP OR LIFT STATIONS

METRO SEWER DISTRCT (MSD), CINCINNATI, OHIO DETAILED PROVISIONS FOR ELECTRICAL PUMP CONTROL PANELS FOR PUMP OR LIFT STATIONS METRO SEWER DISTRCT (MSD), CINCINNATI, OHIO DETAILED PROVISIONS FOR ELECTRICAL PUMP CONTROL PANELS FOR PUMP OR LIFT STATIONS PART 1 - GENERAL 1.01 Scope A. The contractor shall furnish all labor, materials,

More information

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

NEMA Manual. Starters. NEMA Manual Starters Contents

NEMA Manual. Starters. NEMA Manual Starters Contents - February 007 NEMA Manual Starters Contents Page Types B0, B0, Switches.................................... - MS Series, Single-Phase Starters................................ -4 Type B00, Single- and

More information

B. Section Transfer Switches: Automatic transfer switch.

B. Section Transfer Switches: Automatic transfer switch. SECTION 263213 - ENGINE GENERATORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Packaged engine generator set. B. Exhaust silencer and fittings. C. Remote control panel. D. Battery and charger. E. Weatherproof

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps. Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1

More information

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents

More information

Sprecher + Schuh Motor Control and Protection Products

Sprecher + Schuh Motor Control and Protection Products Sprecher + Schuh Motor Control and Protection Products oil and gas pumping, irrigation and piping elevator and hydraulic lifts food processing We consistently work on improving our products and processes

More information

PUMP CONTROL CENTER (PCC)

PUMP CONTROL CENTER (PCC) PART 1 SUMMARY A. In accordance with the plans and specifications, the Contractor shall provide and install a complete pre-fabricated, pre-tested ArcSafe Pump Control Center including all required equipment,

More information

SECTION FIRE PUMP AND CONTROLS

SECTION FIRE PUMP AND CONTROLS SECTION 15320 FIRE PUMP AND CONTROLS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire pump, jockey pump, and controls including necessary accessories as shown in Construction Documents, specified

More information

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines Introduction Before proceeding with the installation or operation of the control panel read all instructions thoroughly, as well as comply with all Federal, State and Local Codes, Regulations and Practices.

More information

BULLETIN 600 SINGLE PHASE

BULLETIN 600 SINGLE PHASE BULLETIN 600 SINGLE PHASE Bulletin 600 Starting and overload protection of small 1-phase AC/DC motors used on the following: Unit heaters Fans Stokers Pumps Refrigeration compressors Bulletin 600 manual

More information

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats. Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code

More information

CXH-A Forced-Air Heater

CXH-A Forced-Air Heater Installation and Operation Instructions CXH-A Forced-Air Heater CXH-A-0 EP to CXH-A-5 EP Class I - Groups C & D, Div. & 2 Class II - Groups E, F & G TB - 65 C (29 F) PF490-6-0242-004 July 20 Table A -

More information

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for

More information

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR. Cast Iron Receivers: For years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Each Receiver comes standard with Inlet connection, an overflow and

More information

Ultra-Safe EXP Unit Heater

Ultra-Safe EXP Unit Heater INDEEO s ULTRA-SAFE EXP explosion-proof unit heater is designed with both safety and versatility in mind. Unique ULTRA-SAFE EXP features include: Industry s Lowest Ignition Temperature ode Rating: T3,

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CRYOGENIC EXPERTS, INC. World Wide Web    Toll Free FOR CEXI Phone (805) Facsimile (805) CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 520-8631 Facsimile (805) 520-8640 I. Installation Instructions CEXI ELECTRIC VAPORIZER

More information

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE Phone (724) 528-9559 Cimco Electronics, Inc. Fax (724) 528-1108 26 Main St.; P. O. Box 248 West Middlesex, PA 16159 Oct., 2002 IMPORTANT NOTICE Dear Customer, We would like to make you aware of a few hardware

More information

Paragon. Induced Draft, Counter Flow Optional Accessories

Paragon. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

Installation Instructions Type XPMC Air Heater for Hazardous Locations

Installation Instructions Type XPMC Air Heater for Hazardous Locations Installation Instructions Type XPMC Air for Hazardous Locations 1 PF500-1 161-302639-005 May 2017 XPMC Air for Hazardous Locations 12", 2 Heat Sinks with Fixed Thermostat 12", 2 Heat Sinks with Adjustable

More information

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES Mounting brackets Heater thermostat (3R only) Power on light HTC energized light Heater (3R only) Snow/Ice

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

Dual Tower Heat Reactivated Desiccant Air Dryer

Dual Tower Heat Reactivated Desiccant Air Dryer Dual Tower Heat Reactivated Desiccant Air Dryer idhpe Dryer idbpe Dryer Eliminate Water from Your Compressed Air System Moisture in compressed air is damaging. Without proper treatment, this vital energy

More information

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL For three-phase heating cables Mounting brackets Nameplate HTC energized light Power on light Heater cycle timed control Heater (3R only)

More information

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel

More information

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014 Wet Pit Installations Pumps suspended from pit or basin cover. Up to 3 Solids Handling 1750 and 1150 RPM Selections. Fiberglass and steel basins available. Steel covers and grouting frames for concrete

More information

Annunciation, Remote Monitoring, Control Industrial Control Panels

Annunciation, Remote Monitoring, Control Industrial Control Panels 7 Annunciation, Remote Monitoring, Control Industrial Control Panels - Solution Brochure www.apt-power.com 433 N. 36 th Street Lafayette, IN 47905 765-446-2343 Rev. 01 2 Digital Remote Annunciation Figure

More information

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS! THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR ON ALL CATALOG ORDERS! TABLE OF CONTENTS SYSTEM MONITORING DEVICES Plug-In Pedestal Alarm System... 4 High

More information

Condensate Boiler Feed Water Make-Up

Condensate Boiler Feed Water Make-Up 1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Low Inlet Condensate Receiver (7 from floor) Close Grained Cast Iron Simplex and Duplex Design To 0,000 SQ-Ft EDR Pump Capacity

More information

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608) Ho-Chunk Gaming POWER SYMBOLS X ELECTRICAL PANEL - REFER TO DRAWINGS FOR WIDTH AND PANEL SCHEDULES PANEL NAMING: XXP-#X: DENOTES PANEL FUNCTION: L = LIGHTING P = GENERAL POWER E = EMERGENCY S = OPTIONAL

More information

STR-Series Indirect-Fired Air Turnover Units

STR-Series Indirect-Fired Air Turnover Units STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil

More information

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Explosion Proof Light - 400 Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Part #: EPL-HB-400W-MH Made in the USA The EPL-HB-400W-MH metal halide, hazardous area light fixture from Larson Electronics

More information

FTA550 JOCKEY PUMP CONTROLLERS

FTA550 JOCKEY PUMP CONTROLLERS FTA550 JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP550E (A) FTA550E XG Jockey Pump Controllers Product Description Failed to start indication Main switch not in Auto alarm Pressure recording

More information

MaxGard. Interconnection Systems. Durability. Performance. Safety

MaxGard. Interconnection Systems. Durability. Performance. Safety 8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections:

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS GENERAL INDEECO Industrial Control Panels are designed to provide years of trouble free operation if properly

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

Hydroflo Prepackaged Pumping Systems

Hydroflo Prepackaged Pumping Systems Hydroflo Prepackaged Pumping Systems Presented to: Presented by: John Curls Jr., P.E. BARNEY S PUMPS INC. What is it? Hydroflo A Hydroflo Packaged Pumping System provides variable volume at a constant

More information

TM Series. Induced Draft, Counter Flow Optional Accessories

TM Series. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Wiring Diagrams Units Produced After April 20, 2009

Wiring Diagrams Units Produced After April 20, 2009 UNIT 38AH 0-034 Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, 460-3-60 575-3-60 380-3-60-3-50, 380/415-3-50

More information

Technology for the Better Future. Medical Air Compressor Systems

Technology for the Better Future. Medical Air Compressor Systems Technology for the Better Future Medical Air Compressor Systems OIL-LESS SCROLL TECHNOLOGY GENTEC s technology and expertise in clean, dry air systems is unmatched. GENTEC manufactures compressors, pumps,

More information

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S Applications Aircraft Hangars/Service Areas hemical Storage/Handling Areas oal Preparation Plants ompressor Stations Grain Elevators Oil Refineries

More information

Drawing Submittal Package

Drawing Submittal Package Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch

More information

X Series (Model B) Explosion Proof Heater

X Series (Model B) Explosion Proof Heater SALES REFERENCE DATE MAY, 2002 5200-2474-000 161-302421-006 INSTALLATION, OPERATION RENEWAL PARTS IDENTIFICATION X Series (Model B) Explosion Proof Heater 2 2 E D Class I Group C & D, Div. 1 & 2 Class

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

FLANGE-MOUNT CENTRIFUGAL PUMPS

FLANGE-MOUNT CENTRIFUGAL PUMPS 40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES GV6 SECTION E PAGE ISSUED /0 REPLACES /0 FLANGE-MOUNT CENTRIFUGAL PUMPS Idel for OEM applications

More information

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING TRA DITIONS AND INNOVATION Since 1922 The first LOVATO Electric headquartes founded in Bergamo in 1922: the starting point of the grand industrial

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL TABLE OF CONTENTS Product Overview... 2 Operation... 3 Installation... 5 Troubleshooting... 9 Ordering Information, Warranty and Service...10

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

Pilot devices Stacklights Signal beacons

Pilot devices Stacklights Signal beacons Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

TECHNICAL MANUAL TRAY DRYER

TECHNICAL MANUAL TRAY DRYER TECHNICAL MANUAL FOR TRAY DRYER MODEL TD321-3 TRAYDRYER MODEL: TD 321-3 Table of Contents Part 1 - Technical Information * Introduction * Catalogue Cut-sheet and Installation Drawing * Warranty Part 2

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS CONTROL PANELS Simplex Panel Duplex Panel Standard Features LISTING: Underwriters Laboratories, UL 508. RATINGS: Model S1 rated up to 120 VAC, 1 Hp,

More information

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete