1 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: ****************************** * InTouch 7.11 Release Notes * ****************************** ********************************************************* Installation ********************************************************* ATTENTION This software requires a license to operate Each component of Wonderware FactorySuite 2000 requires a license to operate. If you have already purchased one or more licenses, they should have been delivered on a floppy diskette with this package. If you have not purchased any licenses, or if you have any questions regarding licensing, you should contact your local Wonderware distributor for ordering information. NOTE If your system requires a hardware key, you will receive a hardware key in addition to your license diskette. For proper operation, the hardware key and license files must all be installed. If you have any questions regarding the installation of your licenses, or hardware key, please contact you local Wonderware Distributor. System Requirements Following are the minimum hardware and software requirements for InTouch Hardware Minimum: For NT and 2000 Professional Systems: 200 MHz Pentium, 128 MB RAM (note 1), 500 MB free hard disk space (note 2) For Windows 2000 Server or Advanced Server systems: 200 MHz Pentium 128 MB RAM (note 1), 500 MB free hard disk space (note 2) Suggested: For NT and 2000 Professional Systems: 700 MHz Pentium 3 or greater, a minimum of 128 MB RAM (note 1), 1000 MB free hard disk space (note 2) For Windows 2000 Server or Advanced Server systems: 700 MHz Pentium 3 or greater, a minimum of 256 MB RAM (note 1), 1000 MB free hard disk space (note 2) Note 1: Base requirement. Must be expanded by 16 MB per every 5K tags. Also add 2 MB for each concurrent user expected to connect to the server.

2 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: Note 2: Actual free disk space requirements may be higher depending on your alarm database logging needs. Operating system Microsoft Windows NT 4.0 SP6 or greater (Workstation or Server) Windows 2000 SP2 (Professional, Server or Advanced Server) Other software Microsoft SQL 7.0 SP3 or Microsoft SQL2000 (optional - MSDE 2000 can be installed by the 7.11 setup if MS SQL is not detected in the system.) The NTFS system is highly recommended for increased data reliability, compression, and performance. Before you install Windows 2000, verify that your hardware is on the Windows 2000 Hardware Compatibility List. Because Microsoft provides tested drivers for only those devices that are listed on the Windows 2000 HCL, using hardware that is not listed on the HCL may cause problems during and after installation. You can find the most recent version of the HCL on the Internet at Peripheral Devices that have an impact on performance include hard disks and network adapters. Hard disks Disk speed is critical for Terminal Server performance. Small Computer System Interface. (SCSI) disk drives, especially devices compatible with Fast SCSI and SCSI-2, have significantly better throughput than other types of drives. Network adapter A high-performance network adapter is recommended, especially if users require access to data that is stored on network servers or client/server applications such as Wonderware InTouch. IMPORTANT! This version of InTouch is not supported on Microsoft Windows 3x and Windows 9x operating Systems. Before You Install You must exit all currently running Windows programs before installing any Wonderware FactorySuite 2000 components. IMPORTANT! Due to the changes in alarm system, all computers running InTouch on a network architecture must be upgraded if one component is upgraded. Also, you cannot upgrade to 7.11, uninstall, and then reinstall an older version of the FactorySuite without first returning the computer to a clean state (for example, using a disk drive ghosting program). Please call your Wonderware Certified Support Center for details and more options. InTouch 7.11 is compatible with both FactorySuite 7.1

3 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: components and FactorySuite 7.11 components except as noted above. If you are running the Windows NT operating system, Service Pack 6a or higher must be installed. If you are running the Windows 2000 operating system, Service Pack 2 or higher must be installed. If the required Service Pack is not installed, you cannot complete the installation. 1. Insert the CD labeled InTouch 7.1/7.11 in the CDROM drive. The InTouch Setup program automatically starts. 2. You will see the Welcome screen. This screen provides a warning to exit all other Windows programs before continuing. This is strongly recommended. When you have exited all other Windows programs, click Next to continue. 3. The FactorySuite 2000 License Agreement displays. Please carefully read the License Agreement. Click Yes to accept the License Agreement and continue with Setup. Click No if you do not accept the License Agreement. NOTE: Clicking No will exit Setup. 4. You will see the User Information dialog box. Enter your name and your company name and click Next to continue. Note: you will see this step only if you are installing InTouch for the first time. 5. You will see the Registration Confirmation message box. If information is correct, click Yes to continue. Note: you will see this step only if you are installing InTouch for the first time. 6. You will see a dialog box asking if you want to view the FactorySuite release notes. Click yes to exit Setup and open the FSRelNotes.txt file in Notepad. Click No to continue with Setup. 7. You will see the main install screen, which lists the FactorySuite components. Click on InTouch to install it. NOTE: If you are installing InTouch as well as one or more other FactorySuite components, install InTouch first. The Install Info button provides additional information on the various FactorySuite bundles. 8. You will see a dialog box asking you which version of InTouch you want installed. Select InTouch 7.11 and click Next to continue with the installation. Note: When you select InTouch 7.11, a message box will be displayed informing you that if you use this PC to generate and display Alarms, and if you are connected to other InTouch nodes that use Alarms, those nodes need to be upgraded to the latest InTouch version. Click Yes to continue with the installation. 9. Once you have selected InTouch 7.11, Setup will verify that your system meets the requirements for InTouch. This may take several minutes, depending on the speed of your system. 10. Next, Setup will check to see if necessary system files

4 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: are already installed on your system. If not, Setup will begin installing them. 11. Setup will now begin the FactorySuite Common Components installation. If you are upgrading an existing FactorySuite component, setup will install the Common Components over the existing Common Components. If you are installing FactorySuite for the first time, Setup will prompt you for the destination folder for the Common Components. Click Browse to select a different folder. Click Next to continue with Setup. NOTE: If you are installing InTouch 7.11 on a clean Windows NT 4.0 system, you ll be prompted to reboot your system after the common component files are installed. After you reboot the system, setup will display Welcome and FactorySuite 2000 License Agreement dialogs. 12. Setup will now prompt you for the User Name, Domain and Password for FactorySuite services to log on Windows NT. Type in the correct information, including password. Click Next to continue. Setup will install the Common Components. 13. If Adobe Acrobat Reader 3.x/4.x is already installed on your system, this step will be skipped, otherwise, Setup will launch the Setup program for Adobe Acrobat Click Continue to install Acrobat Reader NOTE: You need Adobe Acrobat Reader 3.0 or greater, installed on your system, to be able to view and print the FactorySuite online documentation. 14. You will be prompted for the destination directory for Adobe Acrobat Reader Click Browse to select a different destination, or click Next to continue. 15. You will now be prompted to reboot your system. Click OK to reboot your system. When your system has been rebooted and you have logged back on, Setup will automatically continue. You will see the Welcome screen. Click next to resume Setup. Note: you will see this step only if you are installing InTouch for the first time or installing it on a Windows 2000 system. 16. The FactorySuite 2000 License Agreement displays. Please carefully read the License Agreement. Click Yes to accept the License Agreement and continue with Setup. Click No if you do not accept the License Agreement. NOTE: Clicking No will exit Setup. This step will be skipped if you are installing InTouch 7.11 on a clean Windows NT 4.0 system. 17. Setup will continue by checking system requirements and verifying that necessary system files have been properly installed. This process may take several minutes, depending upon the speed of your system. 18. If you are installing InTouch for the first time, you will be prompted for the destination folder InTouch. Click Browse to select a different directory. Click Next to continue Setup. 19. You will now see the Select Components screen. Select the InTouch components you want. NOTE: It is necessary to

5 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: scroll down to see all components. If you do not select Online Manuals you will not have the online documentation installed on your system. Click Next to continue Setup. 20. You will see the Configuration options dialog box. You have three options: Full Development, which includes all InTouch components necessary to create and run InTouch applications; Run-Time only, which includes all components necessary to run InTouch applications; FactoryFocus includes the components necessary to VIEW InTouch applications only. Select the configuration you want. Click Next to continue setup. 21. You will see the Start Copying Files dialog box. Under current settings you will see the options you have chosen. If the settings are not correct, click Back to make changes. Click Next to continue Setup. 22. Setup will now copy all of the files for the components you have selected. This process may take several minutes, depending upon the speed of your system. 23. When Setup finishes copying files, you will see a message box about reviewing Release Notes. This refers to the ITRelNotes.txt (this file), which contains important InTouch specific information. Click OK. You will see another message box saying that Setup is complete for InTouch. Click OK. 24. Setup will display a message box asking whether you want to install MSDE Please read the instructions carefully and click Yes if you want to install MSDE 2000 or No to exit setup. If you click Yes, MSDE 2000 installation will start. Follow on screen instructions to complete the MSDE 2000 installation. Note: If you have already installed Microsoft SQL Server, or MSDE on your system, this step will be skipped. Before you install MSDE 2000, you must first install Microsoft Internet Explorer version 5.5 or later on your system. When installing MSDE 2000 for the first time, you may be asked to reboot your system to start the MS SQL Server. ********************************************************* New Features ********************************************************* Wonderware InTouch 7.11 is comprised of several components that perform Visualization design and presentation, Data Access extensibility to external components/systems, history, event handling, alarm logging, and reporting and analysis tools. Wonderware InTouch has long set the standard for ease of development to allow users to create complex and powerful operator interface displays quickly and easily. Some of the new features in this release are: Distributed Alarm Subsystem With easy configuration and profoundly improved alarm handling performance, the new Distributed Alarm Subsystem of InTouch 7.11 greatly improves the quality of your information while reducing the configuration time. InTouch 7.11 has two new alarm acknowledgement models. Also, dialog boxes and an easy-to-use graphical user interface make alarm configuration simple to

6 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: implement. The basic alarm communication protocol has been updated to use Wonderware s TCP/IP-based SuiteLink protocol. This reduces the amount of CPU and network use, while greatly increasing the alarm update time. SuiteLink Timestamping InTouch 7.11 provides up-to-the-millisecond timestamping of your alarms when the alarm occurs, not when the consumer receives the alarm. Alarm Display The Distributed Alarm Object, familiar to users of InTouch 7.1, has been enhanced. Additional functionality can be provided to an application user to enable preconfigured (by the system designer) views to be selected at runtime, either by a simple right-click command menu or via scripting. The old Standard Alarm Display has been discontinued. Applications that were developed using the old display are automatically upgraded the first time they are opened in WindowMaker. Alarm Flexibility Alarms can now be enabled or disabled directly or indirectly under full control of the application. Alarm suppression can be applied to single alarm classes, tags, or groups to prohibit the display of alarm information on a specific view node. System-wide disablement can block alarm activity at the source. New Alarm Fields A separate alarm comment field allows you to provide more feedback about the alarm. Expanded dot field support allows you greater control over alarms. New Alarm Database and Alarm DB Logger Manager The new InTouch Distributed Alarm Subsystem supports logging alarms and events to a Microsoft SQL Server or MDSE database. This provides the power of a relational database, regardless of the size of your application - and your budget. New visualization tools allow easy and open access to these data tables via the Alarm DB View Control. The new Alarm DB Logger can be manually started on demand or can be configured to run as a Windows service. Alarm logging uses UTC (GMT) timestamping and provides compatibility with DST and across time zones. Alarm Database Maintenance Ensuring your alarm log database is always optimized is straightforward using the standard Purge/Archive utility. Restoration of archived alarm data can be achieved using the Alarm Database Restore utility. AlarmSuite Database Migration Support for AlarmSuite users is still available. However, to enable maximum flexibility, InTouch 7.11 also provides migration tools from legacy Alarm Loggers to the new system. Easy-to-Configure Hot Backup and Resynchronization The new Distributed Alarm System allows you to configure a secondary backup alarm provider, thus establishing a fail-safe system. Alarm provider pairs are configured using a supplied utility. Should a primary alarm provider fail,

7 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: the Distributed Alarm Subsystem seamlessly acquires alarm information from the backup system. On reconnection of the primary node, the Distributed Alarm Subsystem ensures that alarm acknowledgements are resynchronized prior to the returning primary system becoming live. ********************************************************* Known Issues ********************************************************* Warning! Installation may fail on some systems with a built in Intel 81x graphics controller chip at certain resolutions and color settings. To prevent installation failure, change your color settings to 256 colors prior to installation. After installation, you may set the color settings to any value. 1. Indirect tags are not supported as alarm inhibitor tags. 2. AlarmSuite does not support Microsoft SQL Server The maximum length of the AlarmComment dot field is the same as the maximum for all InTouch strings: 131 characters. 4. InTouch 7.11 and FactorySuite WebServer are not compatible If you want to use InTouch 7.11, you must use SuiteVoyager. 5. The Alarm DB Logger Utility does not support the Windows security model for the authentication mode. Only SQL Server authentication mode is supported. If Microsoft SQL Server uses the Windows security model, you will receive the following error message: "Connection to server not available." 6. If InSQL 7.1 is to be installed with InTouch 7.11 on the same node, MSDE 2000 should not be installed. 7. Any service program logged on using local system account attempting to connect to remote machine through Named Pipes protocol will fail due to Windows security implementation since the IPC share utilized by the Named Pipes protocol will require administrative privileges. It is highly recommended to use TCP/IP protocol in such application / configuration. Following are INCORRECT configurations: (1) If you configure Alarm DB Logger as service logged on using local system account and use Names Pipes protocol to connect to remote Microsoft SQL Server. (2) Running InTouch View as service logged on using local system account and the Alarm DB View ActiveX contained inside the View trying to access the remote Microsoft SQL server using Named Pipes protocol. CRI For multi-line alarm queries appearing in the Distributed Alarm Display, line separations display as "garbage" characters. This will not affect the function. CRI NetDDE crashes when attempting to set a topic via DRA. Wonderware has reported this NetDDE issue to Microsoft for resolution. Microsoft has a hotfix for the NetDDE problem. Please see Microsoft Knowledge Base article : q CRI A memory leak occurs while closing and opening windows that include a Distributed Alarm Display Object continuously using a script.

8 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: CRI In previous versions of InTouch, four system tags were available for monitoring the alarm printing activity: $AlarmPrinterError $AlarmPrinterNoPaper $AlarmPrinterOffline $AlarmPrinterOverflow These system tags are not supported in InTouch A future patch will be required to support these four system tags. CRI InTouch 7.11 ships with the Sentinel hardware key driver, version This version does not work with Windows Rainbow Technologies has released version 5.39, which works with Windows NT and Windows If you use version 5.39, you will experience a 15 to 20 second delay when you start up or switch between WindowMaker and WindowViewer. CRI If the Acrobat Reader is installed with the InTouch product and is not launched, it is not possible to open any of the PDF documentation via the Books menu. This is because the Reader needs the user to accept the license agreement in order to be able to access the program. CRI In order to install MSDE 2000 on Windows NT 4.0 SP6a, you must first install Internet Explorer 5.5. CRI If you install MSDE2000 through InTouch install procedure and decide to uninstall and install it again, please go directly to \msde2000 folder to do the installation. After installation if MSDE2000 setup does not ask you to reboot the system, you need to go to Start --> Program --> Startup --> Service Manager to start services for the first time. Or you can reboot the system. CRI For users of the Microsoft Intellimouse with the IntelliPoint mouse driver, the WWLogger may report a warning regarding a reduction of shared memory allocation. This is due to a conflict between the address space allocated for the mouse driver, and the address space desired for the InTouch alarm subsystem. This will be reported in the Wonderware Logger. If you experience difficulties in running the Alarm subsystem with intellipoint, then turn off the IntelliPoint mouse driver before starting WindowViewer. CRI WM.exe will have application error if WM tries to convert old version of InTouch application and the application has windows with instances of ActiveX controls not registered or the application makes calls to script functions for which no dll file is available in the InTouch directory. To overcome this problem, that specific ActiveX control or script.dll file should be installed properly and registered. CRI When trying to acknowledge an already acknowledged alarm using the right-click menu, no changes will be made to the database. CRI In Alarm Hot Backup, when the primary provider comes back up, the first line in the consumer Distributed Alarm Object is blank. A click on the object or a new alarm will display the record. The non-displayed record is properly written to te Alarm history database. ********************************************************* Updates to Documentation

9 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: ********************************************************* CRI InTouch User s Guide, page 7-139, Item 9 Note: You cannot have a secondary alarm provider and a hot backup client in the same node. Should be changed to: Note: A Hot Backup client cannot be configured as a provider in the Hot Backup configuration CRI InTouch User s Guide, Chapter 4 and Chapter 7 InTouch Reference Guide There are three new Distributed Alarm Display dot fields that have not been documented completely. They are:.listchanged Indicates whether there are any new alarms or updates for the Distributed Alarm Object. Usage [ErrorNumber=]GetPropertyD("ObjectName.ListChanged", Tagname); Parameter Description ObjectName Name of the Distributed alarm object. For example, AlmObj_1. Tagname A Discrete type tagname that holds the property value when the function is processed. Remarks This read-only dotfield contains the information about whether there is any change that needs to be updated in the distributed alarm display object. This property is automatically reset on reading the property. Data Type Valid Values Example(s) See Also Discrete (read only) 0 = No new alarms or updates for the display object 1 = New updates for the display object The following statement returns if there are any new alarms or updates for the Distribute alarm object "AlmObj_1" to the Discrete tagname AlmDispStat: GetPropertyD("AlmObj_1.ListChanged", AlmDispStat); Get PropertyD().PendingUpdates Indicates if there are any updates pending for any Distributed Alarm Display. Usage [ErrorNumber=]GetPropertyI("ObjectName.PendingUpdates", Tagname); Data Type Integer.Freeze Reads/writes the freeze status of the Distributed Alarm Display object. Usage [ErrorNumber=]GetPropertyD("ObjectName.Freeze", Tagname) [ErrorNumber=]SetPropertyD("ObjectName.Freeze", Tagname)

10 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: Data Type Discrete (read-write) Valid Values: 0 = Freeze OFF 1 = Freeze ON CRI InTouch User s Guide, page 7-144, "Mapping Alarm Records" There are different terms used in the Alarm Hot Backup Manager Utility "Selected Key Fields" dialog box and for the header names in the.csv (comma separated variable) file. (The.csv is used to create alarm mappings between primary and secondary alarm providers.) The following table outlines the relationship: "Select Key Field" dialog box.csv header names Alarm Group Group Alarm Name Name Alarm Class Class Alarm Type Type Priority Priority Value at Alarm Value Limit Limit Comment Comment The terms shown on the right should be used as header names when creating the.csv file for importing alarm mapping. CRI InTouch User s Guide, page 7-144, "Mapping Alarm Records" should not be used in the.csv file for alarm mapping. CRI InTouch User s Guide, page 7-144, "Mapping Alarm Records" When creating a.csv file using Excel, do not include, inside the cell, since Excel will generate it automatically when the.csv file is being created. CRI InTouch User s Guide, page 7-138, "To add a new Hot Backup pair" and page 7-140, "To edit an existing Hot Backup pair" Regarding the valid characters for the node name, provider, and group: For the node name: 1. It must start with an alphabetical letter. 2. You can use any alphanumeric character. 3. The underscore (_) is the only special character allowed. 4. No other special characters are allowed at any other place of the node name. For the provider name: InTouch is the constant provider name. You cannot change this. For the group name: 1. It accepts all valid characters (A to Z, a to z, 0 to -,?, #, $, %, _, \, &.) 2. It starts with A to Z or a to z. 3. $ can be the only other first character and if it is, then the group name can only be $System. 4. You cannot use a backslash (\) at the end.

11 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: Consecutive backslashes (\\) are not allowed. CRI InTouch User s Guide, page 7-85, "Alarm DB Logger Configuration" When the Alarm DB Logger Manager is used to create databases, tables, and stored procedures, there are three user accounts with different authentication/security levels created at the same time. The Manager has the same authentication/security levels as IndustrialSQL Server. These levels are: Account Password wwadmin wwadmin wwpower wwpower wwuser wwuser CRI almselectioncount() script is not been documented almselectioncount() is a new script function. It takes DAO object name as parameter and returns the count of selected rows to an integer tag Syntax [Result=]almSelectionCount(ObjectName); Example Tag1 = almselectioncount("almobj_1"); CRI InTouch User s Guide, page 7-93, "Context Sensitive Menu Options" The following statements: "True" and type = integer To Set: assign a value not equal 0 or "True" To Get: you will receive the integer value -1 "False" and type = integer To Set: assign 0 or "False" To Get: you will receive the integer value 0 Should be changed to: When an integer (Boolean) type property is assigned a value "True" and is read into (or gotten from) an integer type tagname To Set: assign a value not equal 0 or "True" To Get: you will receive the integer value -1 When an integer (Boolean) type property is assigned a value "False" and is read into (or gotten) from an integer type tagname To Set: assign 0 or "False" To Get: you will receive the integer value 0 CRI InTouch Reference Guide InfoResources() system script function has not been documented: InfoResources() system Returns various system resource values. Syntax IntegerResult=InfoResources(ResourceType,Trigger); Parameter Description ResourceType Integer representing resources to monitor: Type Description

12 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: Returns the percentage of free space for GDI resources. 2 Returns the percentage of free space for USER resources. 3 Returns the number of free bytes of paging file 4 Returns the number of tasks currently running. Trigger Executes the InfoResources() function every time the value of Trigger changes. Trigger can be any tagname (not limited to system variables). This parameter is used for expression fields in animation links only; any value can be used as a place holder when InfoResources() is used in a QuickScript, because this parameter has no effect in a QuickScript. Remarks The particular system resource specified by the integer ResourceType is stored in IntegerResult. Example(s) The following statement executes every minute and returns the current value: InfoResources(1, $Minute) will return 54 {% free} InfoResources(2, $Minute) will return 36 {% free} InfoResources(3, $Minute) will return {bytes} InfoResources(4, $Minute) will return 14 {tasks} System resource values: Case 1&Case 2 GDI and USER are hard-coded to return 50% on Windows NT and Windows Case 3 On Windows NT and Windows 2000, returns "free bytes of paging file." Case 4 On Windows NT and Windows 2000, returns the result of searching of all the top-level windows. It only counts the windows that are visible and do not have any owners. This is not the actual "number of tasks currently running" in the system. Its closest approximation would be the count of items on the Applications tab when you run the Task Manager in Windows NT, or the Close Program window that appears when you press CTRL+ALT+D in Windows CRI InTouch User s Guide, Chapter 7, "Alarm Comment Update" In the past, InTouch allowed you to set a configuration so that when an alarm was generated, the tagname comment was attached to the alarm. For tagnames with alarms, the tagname comment had to serve several functions: documentation of the tagname, explanation of the alarm, and capturing the operator s comment when the alarm was acknowledged. A new dot field, the AlarmComment, has been added to provide a comment specifically for alarms, which is longer (131) and completely separate from the tag comment. When an alarm becomes active, the Distributed Alarm System creates an Alarm Record to track that instance of the alarm, and InTouch attaches the AlarmComment as explanatory text. If the operator provides a comment when ACKing an alarm, InTouch adds this to the Alarm Record as the ACK Comment for that instance of the alarm. The comments for the onset of the alarm and for the acknowledgment are both kept in the Distributed Alarm and both are logged in the alarm database. The Distributed Alarm Object and the Alarm Printer show the Alarm Comment or the ACK Comment, according to whether the instance of the alarm has been ACKed. The next time an alarm occurs on the same tag, the Alarm Comment is again used for the onset of new alarm instance, and the operator can enter

13 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: a different ACK Comment when acknowledging the new instance. You can also configure InTouch to "Retain ACK Comment as Alarm Comment," which enables you to use the ACK Comment to update the Alarm Comment in the tagname database. This features used to update the tagname comment, but now updates the AlarmComment. If you enable this feature, the AlarmComment dot fields will be overwritten during runtime -- including the AlarmComment entries in the Tagname Data Dictionary. InTouch User s Guide, page 7-34 mentions the "Retain ACK Comment as Alarm Comments" option. The documentation should be updated as follows: 6. Select Retain ACK Comment as Alarm Comment if you want comments entered with alarm acknowledgments to be kept as updates to the tagnames AlarmComment dot field. When an operator ACKs an alarm, there is an option to provide a comment regarding the alarm. An ACK comment can also be provided via a script function. If the box is checked for Retain ACK Comment as Alarm Comment, the ACK comment will be retained as the Alarm Comment for the corresponding tagname. InTouch will even update the Alarm Comment in the tagname dictionary. InTouch User s Guide, page 7-45 mentions the "Use Default Ack Comment." This documentation refers to a property of the Distributed Alarm Object: Use Default Ack Comment Controls whether a default comment will be used when an operator ACKs an alarm. If this box is checked and a string is entered, the string will be used during runtime as the default ACK comment. If this box is not checked, when the operator ACKs an alarm, a dialog box appears to let the operator enter a comment, which can be filled in or left blank. InTouch User s Guide, page 7-53, "Attaching Comments to an Alarm Ack Function" The current version of this section does not include one important point: In reporting the alarm status, InTouch now keeps track of both the original Alarm Comment and the ACK comment. Therefore, you do not need to overwrite the Alarm Comment to get the ACK comment into displays, printouts, and so on. The section should be reworded as follows: Each alarm acknowledgment can have a comment attached to it -- whether the ACK is done via the Distributed Alarm Object, a script function, or any other means. The operator acknowledging the alarm can use this comment to add information about the alarm. When an alarm becomes active, the Distributed Alarm System creates an Alarm Record to track that instance of the alarm. For the comment relating to the onset of the alarm, InTouch uses the Alarm Comment box of the tagname s alarm definition in the database. If the operator provides a comment when ACKing an alarm, InTouch adds this to the Alarm Record as the ACK Comment for that instance of the alarm. The comments for the Distributed Alarm System, and both are logged in the alarm database. The Distributed Alarm Object and the Alarm Printer show the Alarm Comment or the ACK Comment, according to whether

14 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: the instance of the alarm has been ACKed. The next time an alarm occurs on the same tag, the Alarm Comment is again used for the onset of new alarm instance, and the operator can enter a different ACK Comment when acknowledging the new instance. You can also choose to use the ACK Comment to update the Alarm Comment in the tagname database. If you enable this feature, the AlarmComment dot fields will be overwritten during runtime -- including the AlarmComment entries in the Tagname Data Dictionary. > To use alarm acknowledge comments to update the AlarmComment field 1. On the Special menu, point to Configure and select on Alarms. The Alarm Properties dialog box appears with the General properties sheet active: TIP If you right-click a text box in any alarm configuration dialog box, a menu will appear displaying the commands that you can apply to the selected text. 2. Select Retain ACK Comment as Alarm Comment if you want comments entered with alarm acknowledgments to be kept as updates to the corresponding tagname s AlarmComment dot field, and to be copied to the Tagname Dictionary. If this is not checked, the ACK Comment will be displayed with the ACKed alarm (in the database, printouts, and displays), but the Alarm Comment will remain unchanged. For more information on alarm comments, see "Tagname Alarm Comments" in Chapter Click OK. InTouch User s Guide, Chapter 4, page 4-33, "Tagname Alarm Comments" Add one paragraph before the final paragraph of "To write runtime changes to the Alarm comment field..." Each alarm acknowledgment can have a comment attached to it -- whether the ACK is done via the Distributed Alarm Object, a script function, or any other means. The operator acknowledging the alarm can use this comment to add information about the alarm. When an alarm becomes active, the Distributed Alarm System creates an Alarm Record to track that instance of the alarm. For the comment relating to the onset of the alarm, InTouch uses the Alarm Comment, which is entered in the Tagname Dictionary. If the operator provides a comment when ACKing an alarm, InTouch adds this to the Alarm Record as the ACK Comment for that instance of the alarm. The comments for the onset of the alarm and for the acknowledgment are both kept in the Distributed Alarm System, and both are logged in the alarm database. The Distributed Alarm Object and the Alarm Printer show the Alarm Comment or the ACK Comment, according to whether the instance of the alarm has been ACKed. The next time an alarm occurs on the same tag, the Alarm Comment is again used for the onset of new alarm instance, and the operator can enter a different ACK Comment when acknowledging the new instance.

15 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: You can also choose to use the ACK Comment to update the Alarm Comment in the tagname database. If you enable this feature, the AlarmComment dot fields will be overwritten during runtime -- including the Alarm Comment entries in the Tagname Data Dictionary Add the following to the end of this page: You may also configure this feature in the WindowMaker GUI as follows: 1. On the Special menu, point to Configure and select on Alarms. The Alarm Properties dialog box appears with the General properties sheet active: TIP If you right-click a text box in any alarm configuration dialog box, a menu will appear displaying the commands that you can apply to the selected text. 2. Select Retain ACK Comment as Alarm Comment if you want comments entered with alarm acknowledgments to be kept as updates to the corresponding tagname s AlarmComment dot field, and to be copied to the Tagname Dictionary. If this is not checked, the ACK Comment will be displayed with the ACKed alarm (in the database, printouts, and displays), but the Alarm Comment will remain unchanged. 3. Click OK. CRI InTouch Reference Guide, page The example for MinRaw is incorrect. The example should be changed to: IF ((Temp01.RawValue > Temp01.MaxRaw) OR (Temp01.RawValue < Temp01.MinRaw)) THEN Show "Instrument Failure Window"; ENDIF; CRI InTouch Reference Guide, page 2-14,.AlarmAccess.AlarmAccess alarms Returns the tagname associated with a selected alarm. The alarm has to be selected by clicking on the Summary Distributed Alarm Display. Usage GetPropertyM("Objectname.AlarmAccess",Tagname); Parameter Description Objectname Name of the Distributed Alarm Object. Tagname Any memory message tagname. Data Type Memory Message (read-only) Example(s) The following statement returns the name of the tagname for a selected alarm: GetPropertyM("AlmObj_1.AlarmAccess", almaccess); Where, AlmObj_1 is the name of the distributed alarm object and almaccess is a memory message tagname that will contain the tagname associated with

16 InTouch 7.11 Release Notes.txt Fri Sep 07 03:39: See Also the selected alarm. If utilized in a Touch Pushbuton QuickScript, this statement returns the value to almaccess when the operator presses the button which can then be used for further processing or display. almaccess would then contain the tagname associated with the selected alarm. GetPropertyM(),.AlarmClass,.AlarmComment,.AlarmDate,.AlarmLimit,.AlarmName,.AlarmOprName,.AlarmOprNode,.AlarmPri,.AlarmProv,.AlarmState,.AlarmTime,.AlarmType CRI InTouch Reference Guide, page 2-7, Tagname Type vs. Dotfield Usage Matrix Addressing Bit Dot field (.00 through 0.31) is missing in the matrix. (See InTouch User Guide for more detail on the usage) Addressing Bit Dot field is applicable for Memory / Integer, I/O / Integer and Indirect / Analog(only Integer) only. CRI In the InTouch Users Guide, page 7-25, Expanded Summary Alarms, the Note reads "When you define a tagname with the Expanded Summary ACK mode, the RTN implies Ack option in the Alarm Properties dialog box must does not apply to the tagname." It should read: When you define a tagname with the Expanded Summary ACK mode, the RTN implies Ack option in the Alarm Properties dialog box does not apply to the tagname.

Before you install ProSeries Express Edition software for network use

Before you install ProSeries Express Edition software for network use Before you install ProSeries Express Edition software for network use The following pages describe system requirements and other information you need to know before installing ProSeries Express Edition

More information

ArchestrA Direct Connect

ArchestrA Direct Connect Table of Contents ArchestrA Direct Connect... 1 Introduction... 1 ArchestrA Direct Connection... 1 ArchestrA Data Source Definition... 2 Data Source Definition... 2 Importing Alarms from ArchestrA... 6

More information

Before you install ProSeries software for network use

Before you install ProSeries software for network use Before you install ProSeries software for network use The following pages describe system requirements and other information you need to know before installing ProSeries software for network use. Important:

More information

Before you install ProSeries software for network use

Before you install ProSeries software for network use Before you install ProSeries software for network use The following pages describe system requirements and other information you need to know before installing ProSeries software for network use. Important:

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide with Hirsch Velocity INT-HIRSCH-B-Rev1 2012 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted

More information

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010 Procidia iware AlarmWorX32 AlarmWorX32 Viewer Siemens Protection AG 2008. notice All / Copyright rights reserved. notice Introduction / Contents Procidia iware is an operator interface software designed

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with

More information

Installing ProSeries software for stand-alone use

Installing ProSeries software for stand-alone use Welcome to ProSeries tax software For information about this topic... Look here... Getting ready Page 1 Installing ProSeries software for stand-alone use Page 1 Setting up the ProSeries program Page 3

More information

Supervisor Standard Edition

Supervisor Standard Edition Supervisor Standard Edition Installation Manual Heat-Tracing Controller Configuration and Monitoring Software INSTALL-119 (Europe) 1 / 18 Contents Section 1 Introduction...3 1.1 Welcome...3 1.2 Vital Information...3

More information

Wonderware InTouch HMI Alarms and Events Guide

Wonderware InTouch HMI Alarms and Events Guide Wonderware InTouch HMI Alarms and Events Guide 10/14/15 All rights reserved. No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical,

More information

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1 CompleteView Alarm Client User Manual CompleteView Version 4.6.1 Table of Contents Introduction... 1 Overview...2 System Requirements...2 Configuration... 3 Starting the Alarm Client...3 Menus...3 File

More information

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms 9 Defining Alarm Conditions Database-Generated Alarms The LookoutDirect alarm service keeps track of error messages and any process elements you have defined alarm conditions for. You can define alarm

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Velocity INT-HIRSCH-A-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this

More information

Yokogawa DX Ethernet Driver Help Kepware Technologies

Yokogawa DX Ethernet Driver Help Kepware Technologies Yokogawa DX Ethernet Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Device Setup 5 Communications Parameters 7 Optimizing Your Ethernet Communications 9 Data

More information

Welcome to ProSeries Express Edition tax software

Welcome to ProSeries Express Edition tax software Welcome to ProSeries Express Edition tax software ProSeries Express Edition is designed for tax professionals who file 50 or more bank product tax returns each season. ProSeries Express offers: An innovative

More information

Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.4 PR 00185

Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.4 PR 00185 Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.4 PR 00185 WONDERWARE FINLAND P.O. Box 38 FIN-00371 Helsinki Finland tel. int. + 358 9 5404940 fax int. + 358 9 5413541 www.wonderware.fi

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organisation whose name is registered with

More information

Installing ProSeries 2005

Installing ProSeries 2005 Installing ProSeries 2005 The following instructions will walk you through Installing and Launching ProSeries 2005. Before you begin your installation, it is very important to make note of the following

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organization whose name is registered with

More information

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.

More information

Managing Network Alarms and Events

Managing Network Alarms and Events 10 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active

More information

LineGuard 2300 Program User Manual (FloBoss 107)

LineGuard 2300 Program User Manual (FloBoss 107) Form A6251 Part Number D301346X012 November 2012 LineGuard 2300 Program User Manual (FloBoss 107) Remote Automation Solutions Revision Tracking Sheet November 2012 This manual may be revised periodically

More information

Monitor Alarms and Events

Monitor Alarms and Events This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,

More information

Alarm Coordination Connected Components Building Block. Quick Start

Alarm Coordination Connected Components Building Block. Quick Start Alarm Coordination Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

Introduction. Application Versions. Keys For An Alarm Query To Be Successful. Tech Note 821 Troubleshooting Wonderware Alarm Provider Query Issues

Introduction. Application Versions. Keys For An Alarm Query To Be Successful. Tech Note 821 Troubleshooting Wonderware Alarm Provider Query Issues Tech Note 821 Troubleshooting Wonderware Alarm Provider Query Issues All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use

More information

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring DeltaV Distributed Control System Product Data Sheet December 2016 DeltaV Analyze Continuous automated DeltaV System alarm system performance monitoring Trends of alarms, events, and user actions Identification

More information

MultiSite Manager. Setup Guide

MultiSite Manager. Setup Guide MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide with Lenel Facility Commander Wnx INT-FCWNX-A-Rev1 2010 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license

More information

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.

More information

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5) Tech Data Sheet D01662GB1_Esgraf 4.1 and Configuration Server 30/2011 1/(5) Esgraf 4.1 graphical user interface, configuration server and fire detectors contamination monitoring Esgraf 4.1 ESGRAF is a

More information

System Galaxy Quick Guide

System Galaxy Quick Guide System Galaxy Quick Guide CONFIGURATION AND OPERATION Integrating CCTV with System Galaxy JAN 2019 SG 11.1.0.2 System Galaxy Quick Guide For CCTV Integration Configuration & Operation Information in this

More information

Alarm Hot Backup Manager can use InTouch, Galaxy, or Galaxy_ as alarm providers when configuring an alarm Hot Backup Pair.

Alarm Hot Backup Manager can use InTouch, Galaxy, or Galaxy_ as alarm providers when configuring an alarm Hot Backup Pair. Tech Note 925 Configuring Alarm Hot Backup Using Galaxy Provider All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for

More information

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management

More information

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0 Avigilon System Integration Guide Avigilon Control Center with AMAG Symmetry Security Management System 7.0 2013-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, HDSM, HIGH

More information

Oracle Communications Performance Intelligence Center

Oracle Communications Performance Intelligence Center Oracle Communications Performance Intelligence Center System Alarms Guide Release 10.2.1 E77506-01 June 2017 1 Oracle Communications Performance Intelligence Center System Alarms Guide, Release 10.2.1

More information

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9 Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,

More information

Alarm Calendar Version 1.10

Alarm Calendar Version 1.10 Alarm Calendar Version 1.10 For Symbian S60 Phones The information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any

More information

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment Control Room Integrated Monitoring Environment INDEX 1. Requirements for software. 2. Installation Instructions. 3. How to Register your Software. 4. Start Using... 5. Operating Instructions. 6. Screen

More information

Guide to the ArchestrA Alarm Control Invensys Systems, Inc.

Guide to the ArchestrA Alarm Control Invensys Systems, Inc. Guide to the ArchestrA Alarm Control Invensys Systems, Inc. Revision A Last Revision: 10/17/08 Copyright 2008 Invensys Systems, Inc. All Rights Reserved. All rights reserved. No part of this documentation

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Picture Perfect 4 INT-PP4-A-Rev1 Copyright 2012 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

Installing ProSeries 2004

Installing ProSeries 2004 Installing ProSeries 2004 The following instructions will walk you through Installing and Launching ProSeries 2004. Before you begin your installation, it is very important to make note of the following

More information

Step 1 - Install ProSeries Basic software

Step 1 - Install ProSeries Basic software Welcome to ProSeries Basic tax software Please follow steps 1 through 3 in this guide: For this step... Look here... Getting ready Page 1 Step 1 - Install ProSeries Basic softwarepage 1 Step 2 - Set up

More information

Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.11 PR 00185

Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.11 PR 00185 Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.11 PR 00185 WONDERWARE FINLAND P.O. Box 38 FIN-00371 Helsinki Finland tel. int. + 358 9 5404940 fax int. + 358 9 5413541

More information

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual. USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor User Manual 8690 Rev B Update: 10/24/2013 1 Table of Contents 1 Introduction.. 3 2 Host

More information

SIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements

SIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management

More information

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1 Avigilon Control Center 5 System Integration Guide with STENTOFON AlphaCom INT-STENTOFON-C-Rev1 2013 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted

More information

Managing Network Alarms and Events

Managing Network Alarms and Events 9 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active

More information

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com

More information

Welcome to ProSeries tax software

Welcome to ProSeries tax software Welcome to ProSeries tax software For information about this topic... Look here... What s new with ProSeries tax software for 2005 Page 1 Getting Ready Computer system requirements Page 3 Getting ready

More information

Security Escort Central Console Software SE2000 Series

Security Escort Central Console Software SE2000 Series Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...

More information

Introduction. Introduction

Introduction. Introduction M-Alarm User s Guide 1-1 Chapter 1 Introduction Introduction M-Alarm allows the user to view, store, and manipulate current alarms received by N1 or BACnet Object Linking and Embedding (OLE) for Process

More information

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER CHAPTER 8 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454. Cisco Transport Controller (CTC) detects and reports alarms generated

More information

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER CHAPTER 9 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454 SDH. Cisco Transport Controller (CTC) detects and reports SDH alarms

More information

Monitor Alarms and Events

Monitor Alarms and Events What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Which Events Are Supported?, page 5 Set Alarm and Event Management Preferences, page 5 Interpret Event and Alarm

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

i-vu CCN 4.0 Owner s Guide

i-vu CCN 4.0 Owner s Guide i-vu CCN 4.0 Owner s Guide CARRIER CORPORAION 2007 A member of the United echnologies Corporation family. Stock symbol UX. 11-808-377-01 07/07 able of Contents ACCESSING YOUR SYSEM... 3 YOUR SYSEM DEAILS...

More information

OnGuard 7.2 Resolved Issues

OnGuard 7.2 Resolved Issues UTC Fire & Security Americas Corporation, Inc. 1212 Pittsford-Victor Road Pittsford, New York 14534 Tel 866.788.5095 Fax 585.248.9185 www.lenel.com Contents OnGuard 7.2 Resolved Issues 1. Introduction...

More information

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe)

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe) OPERATIONS MANUAL Supervisor Heat-Tracing Controller Configuration and Monitoring Software Versions up to 2.7xx INSTALL-118 (Europe) THERMAL MANAGEMENT Raychem-AR-H57576-SupervisorOperations-EN-1706 THERMAL

More information

Architectural and Engineering Specification for a Security Management System. StarNet 2

Architectural and Engineering Specification for a Security Management System. StarNet 2 Architectural and Engineering Specification for a Security Management System StarNet 2 Jan 2, 2018 Page 1 of 12 AE-S2-IN-R1-EN-01/18 This document is intended to provide performance specifications and

More information

2017/11/16 P a g e 1

2017/11/16 P a g e 1 2017/11/16 P a g e 1 Contents What s New... 2 Fixes... 3 Driver Updates... 3 New Sensors... 3 New Features... 3 How To... 4 Security... 4 Auditing... 6 Smart UI/MAPS Title 21 CFR Part 11 Auditing... 6

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations February 2016 Page 1 DeltaV Operate You can easily manage your process with. Robust and secure plant operations Powerful operator interface, optionally up to four monitors Constant visibility and access

More information

English. User Manual. Software. PGuard Multiuser. Rev /

English. User Manual. Software. PGuard Multiuser. Rev / English User Manual Software PGuard Multiuser Rev. 1.0.0 / 070810 Software PGuard-Multiuser Copyright All rights reserved. This document may not be copied, photocopied, reproduced, translated, transferred

More information

Ademco Vista Alarm Panel

Ademco Vista Alarm Panel System Galaxy Quick Guide CONFIGURATION AND OPERATION Ademco Vista Alarm Panel JAN 2018 SG 10.5.6 System Galaxy Quick Guide For Ademco Vista Panel Configuration & Operation 2nd edition JAN 2018 Information

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

3D_ISS. Integrated Software System. User Guide Manual

3D_ISS. Integrated Software System. User Guide Manual 3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development

More information

AK-CS On Board Guide

AK-CS On Board Guide MAKING MODERN LIVING POSSIBLE AK-CS On Board Guide electronic controls & sensors About this guide The AK-CS On Board guide highlights the use of the RMT tool, allowing remote software management. Consult

More information

I/A Series A 2 Software FoxAlert Alarm Manager

I/A Series A 2 Software FoxAlert Alarm Manager Product Specifications I/A Series A 2 Software FoxAlert Alarm Manager PSS 21S-2B2 B4 Current Alarms Display Most Recent Alarms Display Summary Displays By Status Alarm History Display An Extensive Collection

More information

STRIPEYFISH. Utilities for VMware Series. sfvalarms User Guide

STRIPEYFISH. Utilities for VMware Series. sfvalarms User Guide STRIPEYFISH Utilities for VMware Series sfvalarms User Guide S T R I P E Y F I S H sfvalarms User Guide Revision 3 StripeyFish 2013 www.stripeyfish.co.uk Table of Contents Introduction... 1 What is covered

More information

Experion PKS Operator Course EXP01R201 06/2004 Rev 01

Experion PKS Operator Course EXP01R201 06/2004 Rev 01 Experion PKS Operator Course EXP01R201 06/2004 Rev 01 COURSE: Experion PKS Operator Course REVISION: 10 June, 2004 Honeywell IAC courseware is subject to change without notice. Honeywell IAC assumes no

More information

Tech Note 836 Configuring an Alarm Acknowledgement Signature and Using the SignedAlarmAck() Script Function

Tech Note 836 Configuring an Alarm Acknowledgement Signature and Using the SignedAlarmAck() Script Function Tech Note 836 Configuring an Alarm Acknowledgement Signature and Using the SignedAlarmAck() Script Function All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

WorkstationST* Alarm Viewer

WorkstationST* Alarm Viewer GEI-100620U WorkstationST* Alarm Viewer Instruction Guide These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met during

More information

Chapter 6. Alarm History Screen. Otasuke GP-EX! Chapter 6 Alarm History Screen 6-0. Alarm History Screen 6-1. Display Alarm History in List 6-2

Chapter 6. Alarm History Screen. Otasuke GP-EX! Chapter 6 Alarm History Screen 6-0. Alarm History Screen 6-1. Display Alarm History in List 6-2 Chapter 6 Alarm History Screen Alarm History Screen 6- Display Alarm History in List 6-2 Let s Display Alarm History. 6-3 Read Data when Alarms Occur 6-2 Let s Read Data when Alarm Occur. 6-3 Let s Edit

More information

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7. BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.3, October 2017 Copyright 2017 BlackBerry Limited. All Rights Reserved.

More information

PotterNet Fire & Facility Supervising Station

PotterNet Fire & Facility Supervising Station Features Connect up to 1000 Potter panels in a single building, local campus, or multiple sites worldwide using LAN/WAN/Internet Native Ethernet networking connectivity with fire panels and client stations,

More information

Alarm Extension Pack for Wonderware Application Server Demo Guide Ver 1.0 Rev 1.0

Alarm Extension Pack for Wonderware Application Server Demo Guide Ver 1.0 Rev 1.0 Alarm Extension Pack for Wonderware Application Server Demo Guide Ver 1.0 Rev 1.0 WONDERWARE FINLAND P.O. Box 38 FIN-00371 Helsinki Finland tel. int. + 358 9 5404940 fax int. + 358 9 5413541 www.klinkmann.com

More information

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2 Niagara4 Technical Certification Program Student Guide DAY 1 Welcome Course Introduction Platforms & Stations Niagara4 Fundamentals Simple Logic: Hot Water Pump Control (Thermostatic) Simple Logic: Hot

More information

LSM MANUAL PRINCIPLES OF LSM

LSM MANUAL PRINCIPLES OF LSM Page 1 1.0 PRINCIPLES OF LSM 1.1. SYSTEM REQUIREMENTS: LSM 3.1 SP1 OR HIGHER (SUBJECT TO CHANGE) GENERAL Local administrator rights for installation Communication: TCP/IP (NetBios active), LAN (recommended:

More information

Alarm User Guide IGSS Version 9.0

Alarm User Guide IGSS Version 9.0 Alarm User Guide IGSS Version 9.0 Table of Contents Chapter 1: The Alarm List 4 1.1 Introducing the Alarm List 4 Process alarms and 'IGSS Alarm' 4 How is an alarm identified? 4 Alarm characteristics 4

More information

D-Link Central Management System

D-Link Central Management System D-Link Central Management System This seamless management of digital video, audio and data is a powerful solution for large scale installations The D-Link Central Management System is a powerful system

More information

Using ANM Mobile CHAPTER

Using ANM Mobile CHAPTER CHAPTER 19 Date: 3/22/13 This chapter describes Cisco ANM Mobile, which allows you to access your ANM server or ANM Virtual Appliance and manage your devices using a mobile device such as an iphone or

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Security Escort. Operations Guide. Security Escort

Security Escort. Operations Guide. Security Escort Security Escort EN Operations Guide Security Escort Security Escort Operations Guide EN 2 Trademarks The Security Escort system software operates in the Microsoft Windows operating system. This manual

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...

More information

BOSCH GV4 Alarm Panel

BOSCH GV4 Alarm Panel System Galaxy Quick Guide CONFIGURATION AND OPERATION BOSCH GV4 Alarm Panel SG 10.2 (or later) NOV 2012 This is a Galaxy Product Interface Guide. Information in this document is subject to change without

More information

Dashboard for Windows V1.1.0

Dashboard for Windows V1.1.0 User manual Dashboard for Windows V1.1.0 TBS Electronics BV De Factorij 46 1689 AL Zwaag The Netherlands www.tbs-electronics.com COPYRIGHT 2009 (rev1e) - 1 - TABLE OF CONTENTS 1. INTRODUCTION......................

More information

System Description AutroMaster V Presentation System

System Description AutroMaster V Presentation System System Description AutroMaster V Presentation System AMASTERV-SYSTEM/XGB, Rev. B, 2018-05-07, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced in any form,

More information

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04 RADview-EMS/TDM Element Management System for TDM Applications Optimux-1553 1994 2004 RAD Data Communications Publication 07/04 Contents Chapter 1. Introduction 1.1 Overview... 1-1 1.2 System Features...

More information

System 800xA Operations

System 800xA Operations System 800xA Operations System Version 5.1 Power and productivity for a better world TM System 800xA Operations System Version 5.1 NOTICE This document contains information about one or more ABB products

More information

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2017, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACC, AVIGILON CONTROL CENTER,

More information

Table of Contents. i-vu CCN Standard 4.2

Table of Contents. i-vu CCN Standard 4.2 i-vu CCN Standard 4.2 Owner's Guide CARRIER CORPORATION 2009 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-381-01 7/13/2009 Table of Contents Accessing your

More information

SIMATIC. Industrial PC SIMATIC IPC DiagBase V Introduction. SIMATIC IPC DiagBase software components. Quick-Start Guide

SIMATIC. Industrial PC SIMATIC IPC DiagBase V Introduction. SIMATIC IPC DiagBase software components. Quick-Start Guide Introduction 1 SIMATIC IPC DiagBase software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Displaying

More information

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits December 2006 Page 1 You can easily manage your process with. Powerful operator interface, optionally up to four monitors Alarms prioritized by user Secure, standard operating desktop Intuitive graphics

More information