Fapim spa. Dutch Buildings Decree SKG ENG. Building hardware

Size: px
Start display at page:

Download "Fapim spa. Dutch Buildings Decree SKG ENG. Building hardware"

Transcription

1 SKG ENG issued: valid until: Certificate holder Via delle Cerbaie, 114 I Altopascio - Lucca T : F : E : info@fapim.it I : Building hardware Declaration of SKG This certificate is based on BRL 3104: and in accordance with the SKG Regulations approval, product certification and process certification: SKG declares that it has ample reason to assume, that the hardware produced by the holder of this certificate will continue to live up to expectations as defined in this standard, provided the hardware product bears the KOMO -mark in the manner indicated in this certificate as well as the indelible imprint of the SKG-classification. SKG declares that with observance of the conditions mentioned above the hardware satisfies the applicable criteria, set in the Dutch Buildings Decree, as specified on page 2 of this certificate. This certificate is a recognized declaration of quality as mentioned in the Dutch Buildings Decree "Bouwbesluit" consistent with the Tripartite agreement (Staatscourant 132:2006) and the Housing Act. The certificate is included in the "Overzicht van erkende kwaliteitsverklaringen in de bouw" on the website of SBK: For SKG ir. H.A.J. van Dartel Certification manager This certificate is included in the overview on the website of Stichting KOMO: The users of this certificate are advised to verify at if this certificate is still valid and actual. This certificate consists of 6 pages and 1 annex. Dutch Buildings Decree Judged is: -quality system -product -product in use Continuous inspection

2 Number: SKG ENG page 2 of 6 IDENTIFICATION OF THE PRODUCT Products which conform to this certificate can be identified by being indelibly marked with the company logo of the holder of the certificate as well as the SKG burglary resistance mark with the relevant classification in stars. See example beside. In addition, for wholesale purposes to construction companies, either on the package or on the instruction sheet accompanying the product, there should be the unique product number. Here the KOMO -logo has been applied, see example beside. Identification on products LOGO certificateholder or or SKG-certificate number: SKG SUMMARY OF MINIMUM PERFORMANCES DUTCH BUILDINGS DECREE Nr Subject Numerical limit and determining method Performance according to declaration of quality 2.15 Burglary resistance The door or windows (inclusive the installed hardware) satisfies at least RC 2 of NEN 5096 RC 2 of NEN Burglary resistance Derived requirements According chapter 4 of NEN 5096 required for classification according NEN 5096 Burglar resistant classes *, ** or *** according to NEN 5089 Corrosion resistance according to NEN 5089 Minimum class 1 star Producttype dependant: Remarks on the intended use Façade elements shown to comply with resistance class 2 of NEN 5096 achieve this performance with the products that are certified under these BRL A recognized quality certification or a KOMO approval on the façade element is thus a conclusive evidence. Determined according to NEN-EN 1906 Determined according to NEN-EN 1935 Determined according to NEN-EN Determined according to NEN-EN 1303 Determined according to NEN-EN 1670 Durability according to NEN 5089 Determined according to NEN-EN 1303 Determined according to NEN-EN 1906 Determined according to NEN-EN 1935 Determined according to NEN-EN Declaration by manufacturer Lockability If not lockable: - tamperproof - limited application grade 3 grade 3 grade C grade A grade 3 Producttype dependant: grade 6 grade 2 suitability for leaf-weight and frequency grade C cycles Producttype dependant, with detachable key Depending on the producttype this satisfies appendage I of NEN 5096 warning about application restrictions shields and roses hinges locks cylinders other products cylinders shields and roses hinges locks bolts No restrictions in application Applied in façade elements without glass or with burglary resistant glazing (according to NEN-EN 356, for Class Table 1 of NEN 5096) PRODUCT TYPES This KOMO productcertificate regarding the production and supply of building hardware for roof- and facade-elements is applicable to the following types of products: Product type Part of this KOMO productcertificate Relevant for Dutch Buildings Decree 01 Single lock no yes Y If according to EN 179, EN 1125 or EN 12209, for escape or fire doors 02 Multipoint lock no yes Y If according to EN 179 or EN 1125, for escape or fire doors 03 Single bolt no yes N 04 Multipoint bolt yes yes N 05 Cylinder no yes N 06 Security furniture no yes N 07 Hinge yes yes Y If according to EN 1935, for escape or fire doors 08 Seam protector no yes N 09 Barrier device no yes N 10 Pad lock no no N 11 Window handle no yes N 12 Locking plate no yes Y In combination with locks For the current list and detailed specifications of the products covered by this KOMO productcertificate: see on CE

3 Number: SKG ENG page 3 of 6 1. TECHNICAL SPECIFICATIONS 1.1 Subject Factory-produced building hardware products with attachments, meant for application in doors/windows in buildings. 1.2 Locks, single and multipoint type Locks are designed to close doors from the outside and consist of metal and (for less essential parts) polymer components and are made in single- and Multi-point type. The metal deadbolt of locks can be block- hook- or pin-shaped. Locks can be equipped with a latch made of metal or plastic and are constructed in such a way that they can be operated from within as well as from the outside. Locks can be mounted on the surface of the door (Rim) as well as inside the doorleaf (Mortice). Locks can have an integral codebearer as well as have a recess for mounting a separate codebearer (usually called a cylinder). Locks can be supplied including a keeper for the latch and deadbolt, or they can refer (in the manual) to a specific keeper. Locks on escape-doors are constructed in such a way that the deadbolt can be withdrawn in a single movement. Locks are built from materials that are inherently corrosion-proof or have been treated in an adequate way to reach this end. 1.3 Bolts, single and multipoint type Bolts are intended to secure doors and windows from within and consist of metal and (for less essential parts) polymer components and are made in single and multi-point type. The metal bolt can be block- hook- or pin-shaped. Bolts are built in such a way that they can only be operated from within and can be mounted either on the surface of the door or window or inside the door or window leaf. Bolts can be lockable by key, be limitedly lockable or not at all. Lockable versions usually have an integral code-bearer. Bolts are supplied including a keeper. Locks with a flight mode are constructed such that a movement of the deadbolt can be withdrawn. Bolts are built from materials that are inherently corrosion-proof or have been treated in an adequate way to reach this end. 1.4 Cylinders Cylinders are assembled from metal or (for less essential parts) polymer components and a matching code-bearer. Cylinders are constructed in such a way that they can only be opened with the matching key. Cylinders can be single (half-), double, (whole) or knob-type. Cylinders are built from materials that are inherently corrosion-proof or have been treated in an adequate way to reach this end. 1.5 Furniture (shields and roses) By furniture we mean a provision to protect the cylinder from attack from the outside and it generally takes the shape of an outerand inner plate, inter-connected by screws going through the doorleaf. Furniture consists of an assembly of metal and (for less vital pieces) polymer components. Furniture comes with holes to accomodate the cylinder. If there is no further protection for the cylinder the leeway between the cylinder and the hole shall never exceed 1 mm. Furniture may come equipped with additional features to protect the cylinder, notably to shield against core-pulling. Furniture may be supplied with fixed leverhandles or push-pads or facilities to operate the latch. Furniture is built from materials that are inherently corrosion-proof or have been treated in an adequate way to reach this end. 1.6 Hinges Hinges are meant to hang doors or windows and consist of metal or (for less essential parts) polymer components. Hinges can be leaf-type or paumelles, with or without bearings. Hinges can be mounted on the leaf of the door or on the edge of the door, or a combination of both. Hinges are built from materials that are inherently corrosion-proof or have been treated in an adequate way to reach this end. 1.7 Seam protectors and barriers Seam protectors are meant as an additional security feature and are made of metal or (for less essential parts) polymer components. Barriers are meant as an additional feature on tilt-windows and the like. Both products are nearly always for retrofitpurposes. Seam protectors and barriers are both made from materials that are inherently corrosion-proof or have been treated in an adequate manner to reach this end. 1.8 Padlocks Padlocks are meant as a supplemental means of locking doors and windows, and in general for securing all kinds of objects. Padlocks are made from various metals, and, for less vulnerable parts, polymers. Remark: The use of padlocks on doors and windows in housing is unusual in the scope of the building code. Padlocks may have an integral codebearer or a provision to mount a separate code-bearer, (usually called a cylinder). Padlocks may be supplied with a shackle for specific applications. Padlocks are built from materials that are inherently corrosion-proof or have been treated in an adequate way to reach this end. 1.9 Miscalleneous Products that can contribute to burglarproofing windows and doors and are not in one of the above-mentioned groups are called miscellaneous. The college of experts has determined demands on and tests for these products.

4 Number: SKG ENG page 4 of Instruction manual The building-hardware has to be supplied with a clear instruction-manual in Dutch. The manual describes or contains, where applicable, the following information: a. a complete set of (standard) mounting-details; b. the dimensions of any recesses into which the hardware has to fit; c. an itemized list of all fastenings required; d. drill-template with clear instructions; e. prerequisites the user should observe to achieve a fully burglarproof result, such as the combination with other products in case of composite assemblies; f. maintenance instructions, specifying the products required; g. any limitations regarding validity or applicability, for example non-lockable products; h. instructions for proper use (e.g. electronic locks, or Multi-turn locks, snibs, etc.); i. anything else that may be required for correct assembly and maintenance. Examples: - do not drill through the lock whilst installing protective plates; - remove woodchips before installing the lock; - apply primer or paint inside the lock-recess Products meant for the DIYmarket should have a complete instruction manual each. Products meant for the professional market can be supplied with just one manual for a specific buyer. 2. PERFORMANCE REGARDING TO THE DUTCH BUILDINGS DECREE 2.1 Performance from the security point of view - BURGLARY RESISTANCE; BB-Dep Burglary resistance; BB-Dep Facade elements in which products that satisfy these requirements have been mounted according to the manufacturers instructions satisfy at least class 2 of NEN 5096 provided that the technical specification of the used door or windows are at least equal to the reference doors or windows as mentioned in NEN Remark 1: An official quality declaration like a KOMO-Attest or certificate is a sufficient prove for burglar resistant doors or windows. Remark 2: This applies only to those products mentioned in H1- Products, as relevant for the Dutch Buildings Decree (Bouwbesluit). 2.2 Performance regarding demands derived from NEN Lockability according to NEN 5096 par Those bolts and locks which can t be locked have to withstand the test described in annex 1 of NEN Corrosion resistance according to NEN 5096 par Building hardware has to satisfy the demands of NEN 5089 regarding corrosion resistance and endurance Requirements to cylinders according to NEN 5096 par Cylinders that satisfy class 2 of NEN 5096 have to achieve at least a 2-star rating in NEN OTHER PERFORMANCE REQUIREMENTS BASED ON BRL Performance regarding burglary resistance Burglary resistance in existing buildings Any retro-fit door or window fitted according to the manufacturers instructions and satisfying this certificate qualifies according to the police safe housing directive (PKVW) for existing buildings, provided the facade element satisfies the other directives in PKVW Locks and multipoint locks Main- and supporting locks according to burglary resistance class 1-star, 2-star or 3-star give the performance indicated in the tables. In the manual test the main- and supporting locks have been tested singly (2-star and 3-star) or as a set (1-star). The manual test has been applied to the combination of the lock and the recommended/ supplied keeper. Single locks and keepers Performance 1-star 2-star 3-star * Security according NEN-EN Type of key operating according NEN-EN A, B, D, E, G en H Key identification requirement (keyboard locks) according to NEN-EN B B D Manual test according NEN 5089 (resistant time in min. / tool set) 3/A not independent Multipoint locks and keepers Type of key operating according NEN-EN A, B, C, D, E, F, G en H 3/A 5/B

5 Number: SKG ENG page 5 of Bolts Bolts according burglary resistance class 1-star, 2-star, and 3-star will give the results mentioned in the table. In the manual test the bolts have been tested as a pair 1-star or singly 2-star or 3-star. The manual test has been applied to the combination of the lock and the recommended/ supplied keeper. Single bolts and keepers Performance 1-star 2-star 3-star * Handle - lever withstands force according par of NEN Nm 35 Nm 100 Nm Manual test according NEN 5089 (resistant time in min. / tool set) 3/A not independent 3/A 5/B Multipoint bolts (incl. tilt and turn) Handle - lever withstands force according par of NEN Nm 100 Nm Cylinders Cylinders according burglary resistance class 2-star and 3-star will give the results mentioned in the table. Key related security according NEN-EN Attack related security according NEN-EN 1303 digit 7 1 a) 2 Permutation not reducible from extreme position of detainers yes yes Minimum number of effective detainers when completely compressed 3 3 Resistance against manipulation, points according table 7 of NEN a) Resistance to attack by plug / cylinder extraction 7 kn (this value is not conform 15 kn according table 10 of EN 1303) Furniture (a set of) Furniture according burglary resistance class 2-star and 3-star will give the results mentioned in the table. Security grade volgens NEN-EN The dimensions of the hole for the cylinder is maximum 1 mm more than the nominal dimension of the cylinder Hinges (a set of) Hinges according burglary resistance class 2-star and 3-star will give the results mentioned in the table. In the manual test the hinges have been tested as a set, and are therefore certified as a set. yes yes Seam protectors and barriers Seam protectors and barriers according burglary resistance class 1-star, 2-star, and 3-star will perform as indicated in the table. Seam protectors Performance 1-star Manual test according NEN 5089 (resistant time in min. / tool set) 3/A not independent Barriers *

6 Number: SKG ENG page 6 of Performances related to a specific function Locks Emergency exit devices and panic exit devices which contain locks with an escape-option do satisfy NEN-EN 179 and NEN-EN Because these devices are by definition not lockable this demand is waived and the burglary resistance-marking is duly modified Bolts Emergency- and panic-escapes with bolts do satisfy NEN-EN 179 or NEN-EN Because these devices are by definition not lockable this demand is waived and the burglary resistance-marking is duly modified Cylinders At the moment a key is removed from a cylinder the cam protrudes outside the cylinder Furniture (shields and roses) In the instruction sheet there is an indication for which thickness of doorblade the furniture is intended, the thickness of the furniture itself and the provision that a cylinder should never protrude more than 3 mm outside the shield or rose. If the furniture includes protection against core-pulling it satisfies the demands of A of NEN-EN 1906, where the burglary resistance 2-star equals grade 2 and 3-star equals grade Hinges None Seam protectors and barriers None. 3.3 Performance regarding corrosion resistance and durability Locks Locks satisfy grade C for corrosion resistance according to NEN-EN Locks satisfy grade C for durability according to NEN-EN Bolts Bolts satisfy grade 3 for corrosion resistance according to NEN-EN After the test the bolt should still function Cylinders Cylinders satisfy grade A for corrosion resistance according to NEN-EN Cylinders satisfy grade 6 for durability according to NEN-EN Furniture (shields and roses) Those parts of the furniture usually exposed to the elements satisfy grade 4 for corrosion resistance according to NEN-EN The other parts satisfy grade 2 for corrosion resistance according to NEN-EN After the corrosion-test those parts visible in assembled state show no visible signs of corrosion. Burglary resistant furniture satisfies grade 6 for durability according to NEN-EN Hinges Hinges satisfy grade 3 for corrosion resistance according to NEN-EN Hinges satisfy a durability-grade matching a specific door or window mass according to NEN-EN Seam protectors and barriers Seam protectors and barriers satisfy grade 3 for corrosion resistance according to NEN-EN HINTS FOR THE CLIENT 1. Upon delivery of building hardware covered by this certificate please verify that: the products supplied match those specified in the order; the products carry the indelible brandname and SKG classification; the products have no visible damage due to transport. 2. Check whether this certificate is still valid on: 3. If any of these demands have not been met, please contact: 1e ; or if necessary: 2 e SKG

7 Via delle Cerbaie, 114 I-55011, Altopascio - Lucca KOMO certificaatnummer - SKG NL Bijlage bij KOMO productcertificaat - overzicht van SKG gecertificeerde producten Totaal aantal punten: 100 Totaal aantal certificaten: 6 Versie lijsten PKVW - BB Pnt Afgifte d.d SKG-certificaat nr. Productnaam Klasse Artikelnummer(s) Productlogo(s) Geschikt voor toepassing L1 L2 L3 L4 L samengesteld beslag met raamkruk ** GALIPLUS 2, GALIPLUS 4 FAPIM Metaal, Raam naar binnen draaiend L samengesteld beslag met raamkruk ** SYNCRO FAPIM Metaal, Raam naar binnen draaiend L set van 2 opbouwpaumellen ** 2 stuks LOIRA+ 6654/6654A: 7000(V/Vi/i), 7010(V/Vi/i), 7020(V), 7030(V), 7040(V/Vi/i), 7050(V/Vi/i), 7060(V), set van 2 opbouwscharnieren met ** 2 stuks LOIRA+ 6654/6654A: 7003(V), 7013(V/Vi/i), penborging 7023(V), 7033(V), 7043(V), 7053(V), 7063(V), 7073(V) FAPIM FAPIM Metaal, Deur naar binnen draaiend, Deur naar buiten draaiend N Metaal, Deur naar binnen draaiend, Deur naar buiten draaiend N set van 3 opbouwpaumellen *** 3 stuks LOIRA+ 6654/6654B: 7000(V/Vi/i), 7010(V/Vi/i), FAPIM Metaal, Deur naar binnen draaiend, Deur naar buiten draaiend N set van 3 opbouwscharnieren met *** 3 stuks LOIRA+ 6654/6654B: 7003(V), 7013(V/Vi/i), FAPIM Metaal, Deur naar binnen draaiend, Deur naar buiten draaiend N

ADDITIONAL REQUIREMENTS

ADDITIONAL REQUIREMENTS SKG-IKOB AE 3104 12-07-2017 ADDITIONAL REQUIREMENTS FOR THE ISSUE OF A KOMO APPROVAL-WITH-PRODUCT CERTIFICATE FOR SECURITY PRODUCTS FOR WINDOWS AND DOORS BASED ON BRL 3104 Established by the Board of Experts

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK UK Test Laboratory School Street Willenhall WV13 3PW Contact: Mr I Bridge Tel: +44 (0) 1902 364600 Fax: +44 (0) 1902 364681 E-Mail: ian.bridge@assaabloy.com

More information

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf Thief Resistant Lock Assemblies Thief resistant lock assemblies - Key egress BS 3621: 2007 Thief resistant lock assemblies - Keyless egress BS 8621: 2007 Thief resistant dual mode lock assemblies BS 10621:

More information

GUIDELINIE ECB S R10. March European Certification Body GmbH

GUIDELINIE ECB S R10. March European Certification Body GmbH March 2017 GUIDELINIE ECB S R10 Additional requirements for burglar resistant products within the scope of EN 1627 according to guideline ECB S C10 with electromechanical locks, striking plates or security

More information

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC C/TC 33 - Doors, windows, shutters, building hardware and curtain walling Standard reference Title Directive 107:1980 Methods of testing windows - Mechanical test 129:1984 130:1984 179:2008 477:1995 478:1995

More information

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Guide to interpreting Markings for Single Axis Fire Doors Hinges Guide to interpreting Markings for Single Axis Fire Doors Hinges An overview of BS EN 1935: 2002: Building Hardware. Single Axis hinges as relates to Fire doors. INTRODUCTION. It is a criminal offence

More information

Mechanically operated locks and locking plates

Mechanically operated locks and locking plates Mechanically operated locks and locking plates to BS EN 12209:2016 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Mechanically operated locks and locking plates to BS EN 12209:2016 dhf Best

More information

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123 Ironmongery Schedule Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123 Ironmongery Performance Specifications 1.0 Door Hardware Briton Levers, Escutcheon s & Bathroom

More information

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation Annex to ISO/IEC 7025:2005 declaration also Chamber Commerce no. 246437 This annex is valid from: 06-2-206 to 0-2-207 Replaces annex dated: 25-06-205 Locations where activities are performed under accreditation

More information

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with best practice guide Electromechanically operated locks & striking plates to BS EN 14846: 2008 in association with Permission to reproduce extracts from BS 3621:2007 and BS EN 12209: 2003 is granted by

More information

Panic and Emergency Exit Devices

Panic and Emergency Exit Devices Panic and Emergency Exit Devices BS EN 1125: 2008 & BS EN 179: 2008 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Panic and Emergency Exit Devices BS EN 1125: 2008 & BS EN 179: 2008 dhf

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Unit 3 Wednesbury One Black Country New Road Wednesbury West Midlands

More information

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123 Ironmongery Schedule Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123 Ironmongery Performance Specifications 1.0 Door Hardware Briton Levers, Escutcheon s & Bathroom

More information

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123 Ironmongery Schedule Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123 Ironmongery Performance Specifications 1.0 Door Hardware Briton Levers, Escutcheon s & Bathroom

More information

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

FLAMEBREAK. Rev.D Mechanical Performances - General: TM FLAMEBREAK Mechanical Performances 1 Mechanical Performances - General: NOTE: Doorsets using FLAMEBREAK based doors have been tested to performances that exceed the DD171 / BS EN 1192 minimum requirements

More information

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123 Ironmongery Schedule Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123 Ironmongery Performance Specifications 1.0 Door Hardware Briton Levers, Escutcheon s & Bathroom

More information

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware 2017-05-12 for the Kiwa product certificate for Extractable shower hoses for sanitary tapware Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123 Ironmongery Schedule Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123 Ironmongery Performance Specifications 1.0 Door Hardware Briton Levers, Escutcheon s & Bathroom

More information

Specifying Security Hardware for Doors

Specifying Security Hardware for Doors Specifying Security Hardware for Doors A guide for security and building professionals, installers and locksmiths produced by dhf and The Glass and Glazing Federation. www.dhfonline.org.uk 01 dhf Best

More information

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D BRL-K629/03 Date 01-02-2012 Evaluation Guideline for the Kiwa product certificate for Backflow protection devices Family E, Types A, B, C and D Preface Kiwa This (BRL) has been drawn up by Kiwa's Board

More information

25 th November Title:

25 th November Title: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

BRL-K602. Datum Evaluation Guideline

BRL-K602. Datum Evaluation Guideline Datum 2018-09-04 for the Kiwa product certificate for valves, control valves and non-return valves for drinking water transport and drinking water distribution systems Preface This evaluation guideline

More information

Rim Locks. Rim Locks Index. Standards & Approvals. Keying Groups. Keys

Rim Locks. Rim Locks Index. Standards & Approvals. Keying Groups. Keys Rim Locks Index Introduction How to Specify Introduction What Type of Door? What is? Features and Functions Photo Gallery Range Table High Security Double Security Security RL2 RL3 RL3 RL3 RL4 RL5 Chubb

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water BRL-K762 Datum 2017-07-03 Concept design for the Kiwa product certificate for steel pipes for the transport of drinking water 478/160822 Preface This evaluation guideline has been accepted by the Kiwa

More information

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN Windows and Doors Single-axis hinges to BS EN 1935 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Windows and Doors - Single-axis hinges to BS EN 1935 dhf Best Practice s This publication

More information

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie Normative document: EN ISO/IEC 7025:2005 This annex is valid from: 24-0-208 to 0-2-202 Replaces annex dated: 06-2-206 Location(s) where activities are performed under accreditation Head Office Poppenbouwing

More information

DATA CENTRES & IT SECURITY. High security solutions

DATA CENTRES & IT SECURITY. High security solutions DATA CENTRES & IT SECURITY High security solutions Abloy UK is excited to introduce a new energy-saving range of products including electric locks, Protec2 CLIQ, access control and door closers. Energy-saving

More information

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt Product ID: KL.1902 Name: Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55 Centres C=N/A Follower (mm) 8 Latch Bolt N/A Mechanism Euro- Profile Forend Finish SSS Rebates available (mm) KL.1902A

More information

ABLOY EFEND. New name for security

ABLOY EFEND. New name for security ABLOY EFEND New name for security SET SECURITY TO NEXT LEVEL ABLOY is now available in ANSI door environment. OPTIONS FOR EVERY NEED Inclusive product range includes both electric and mechanical locking

More information

Electromagnetic Locking Devices Performance Requirements

Electromagnetic Locking Devices Performance Requirements Technical Specification Electromagnetic Locking Devices Performance Requirements DHF TS 010:2016 Technical specification produced by dhf www.dhfonline.org.uk Contents Foreword 1. Scope 2 ANNEX A Bodies

More information

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers 01-02-2012 Evaluation guideline for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers Preface This evaluation guideline has been accepted by the board of experts

More information

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 31-2 KE 31-2 March 2012 GASTEC QA Approval Requirements 31-2 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

HOME SECURITY. 2 - Basic security

HOME SECURITY. 2 - Basic security HOME SECURITY No special skills are required, but some experience of electrical work would be an advantage when fitting a burglar alarm. It is estimated that as many as 60% of burglaries are made by entry

More information

The global leader in door opening solutions

The global leader in door opening solutions URE The global leader in door opening solutions URE The safety of everybody entering your building is your responsibility. With legislation and standards changing regularly, it is essential that you keep

More information

Ironmongery Performance Specifications

Ironmongery Performance Specifications Ironmongery Schedule Prepared for: ABC Architects Project Title: XYZ University Science Suite Our Ref: ABC123 Contractor: Kino Constructions Scheduler: John Smith Dip GAI Ironmongery Performance Specifications

More information

About the Instructor & Presenter:

About the Instructor & Presenter: About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran in the door and hardware industry, Mr. Baillargeon

More information

PHA Panic Hardware for timber doors

PHA Panic Hardware for timber doors PHA 2500 Panic Hardware for timber doors DORMA PHA 2500 Panic Hardware for timber doors The DORMA PHA 2500 Panic Hardware system. PHA 2500 combined with Panic mortice lock for single- and double-leaf doors

More information

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000 Market Introduction DORMA Modular Panic Hardware System PHA 2000 / PHB 3000 Introduction PH System 1 Introduction European Panic Hardware System PHA 2000 PHB 3000 External trim series PHT 3900 compatible

More information

Panic & Emergency Exit Hardware

Panic & Emergency Exit Hardware Panic & Emergency Exit Hardware Panic & Emergency Exit Hardware Contents ARRONE Architectural Plus Panic & Emergency Exit Hardware 361-370 ARRONE Panic & Emergency Exit Hardware 371-381 Fapim Panic &

More information

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001 CI/SfB (31.9) Xt7 June 2009 best practice guide Padlocks & padlock fittings to BS EN 12320: 2001 in association with Permission to reproduce extracts from BS EN 12320: 2001 is granted by BSI. DHF BEST

More information

Controlled Door Closing Devices

Controlled Door Closing Devices Controlled Door Closing Devices to BS EN 1154: 1997 + A1:2003 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Controlled Door Closing Devices to BS EN 1154: 1997 + A1:2003 dhf Best Practice

More information

Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK

Guide to Fire and Escape Doors: Part 1 - What are they?  Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK www.gai.org.uk Introduction This will be a brief overview of the subject,

More information

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries. Panic Exit Devices We take the worry out of protecting what s valuable to you. Lockwood: no worries www.lockweb.com.au Contents FLUID Series Exit Device Panic Exit Hardware FLUID Series Exit Mortice Lock

More information

ENGINEERING EVALUATION

ENGINEERING EVALUATION ENGINEERING EVALUATION REPORT NUMBER: 100378137MID-002 ORIGINAL ISSUE DATE: April 26 th, 2011 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett

More information

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions HD72 Euro Profile Mortice Lockcase The high performance lock that goes beyond the standard ASSA ABLOY, the global leader in door opening solutions UNION Trusted by professionals From our first lock made

More information

CATALOGUE. Security represents your sense of worth. Security systems and locks. Yale. Systems Professional Security Products

CATALOGUE. Security represents your sense of worth. Security systems and locks. Yale. Systems Professional Security Products CATALOGUE Security systems and locks Yale Systems Professional Security Products About Master Security Systems and Locks Trading as Master, Master Security Systems and Locks is a branch of The Depo Limited

More information

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 31-1 KE 31-1 March 2012 GASTEC QA Approval Requirements 31-1 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters /08 2018-01-15 for the Kiwa product certificate for Water meters Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which all relevant parties in the

More information

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control? Meeting the requirements of the Equality Act & Fire regulations Which Door Control? Introduction There are two main considerations in specifying door controls: Does it meet the requirements of the Equality

More information

Make it Hard for Them to Hurt Us. Perimeter

Make it Hard for Them to Hurt Us. Perimeter Keeping Home Safe Safety and security starts at home. It is the responsibility of each of us to do all we can to Make it Hard for Them to Hurt Us. This simple check list is designed assist in identifying

More information

Window & Door Security

Window & Door Security Your Guide to Window & Door Security An ASSA ABLOY Group brand Securing your home This booklet has been designed with you in mind and answers the simple question of What locks should I put where? when

More information

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions White Paper Keeping up with compliance: Escape doors standards The global leader in door opening solutions Introduction When it comes to access control, there is no greater responsibility than specifying

More information

Public and Government Buildings

Public and Government Buildings Public and Government Buildings 1 For all HOPPE door- and window handles... 2 Contents Hardware from HOPPE: Simple durable secure page 4 Education page 6 Healthcare page 10 Leisure and Hospitality page

More information

PANIC HARDWARE ACCESSORIES & PARTS

PANIC HARDWARE ACCESSORIES & PARTS PANIC HARDWARE ACCESSORIES & PARTS DX 200 Keepers and strikes PO OSK 3405 Keepers for the vertical bottom latch. Forms a set together with the keeper shown below (PO BSK 3405A) for assembly on a stone

More information

Perimeter Security. Gates and fences are the first signs of a secure home and act as a good deterrent to intruders. Make sure they are in good repair.

Perimeter Security. Gates and fences are the first signs of a secure home and act as a good deterrent to intruders. Make sure they are in good repair. Property Security 1 Perimeter Security Gates and fences are the first signs of a secure home and act as a good deterrent to intruders. Make sure they are in good repair. 1. Keeping your front gate closed

More information

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations Updated to include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations WHICH DORMA DOOR CONTROL? INTRODUCTION There are two main

More information

Hardware Selection Process

Hardware Selection Process ASSA ABLOY s door hardware products are ideal for a wide range of situations from private homes to the commercial or public sector and for heavy or lightweight doors. The modular design simplifies planning,

More information

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012 KE 15 January 2012 GASTEC QA Approval Requirements 15 for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas Foreword These GASTEC QA Approval requirements have been

More information

Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range

Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range Newstar Locks Nightlatch Range DIN Range Standard & Escape London Fire Brigade Range BS Range NEWSTAR form and function for life DIN Escape lock range Split follower escape sash lock ESL1 60 1. Lever handle

More information

Security Screen Door Hardware

Security Screen Door Hardware Security Screen Door Hardware 10YEAR whitco.com.au Leichhardt Sliding Security Screen Door Lock Application/Description Single & Multi point mortice sliding security door lock Features and Specifications

More information

HOME SECURITY INFORMATION

HOME SECURITY INFORMATION HOME SECURITY INFORMATION Home security information Home security information Within this page there is stacks of Home security information to help you improve the security of your home. We pride our selves

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE McClellan Blakemore Architects New Warehouse Facility for SECTION 08710 DOOR HARDWARE PART 1 GENERAL 1.01 SECTION INCLUDES A. Hardware for wood and hollow steel doors. B. Hardware for fire-rated doors.

More information

Fire Rated Door Assemblies: Compliant Designs

Fire Rated Door Assemblies: Compliant Designs Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported

More information

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 6 KE 6 March 2012 GASTEC QA Approval Requirements 6 for the GASTEC QA product certificate for Plumbing fittings with ends for capillar soldering and/or thread connections Foreword These GASTEC QA Approval

More information

GASTEC QA. Approval Requirements 69-1

GASTEC QA. Approval Requirements 69-1 KE 69-1 May 2014 GASTEC QA Approval Requirements 69-1 for the GASTEC QA product certificate for Manually operated ball valves and closed bottom taper plug valves for gas installations for buildings Foreword

More information

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety issued by an Accredited Testing Laboratory Contact person Christian Larsson 2016-09-05 6P01958A 1 (3) Safety +46 10 516 57 61 Christian.Larsson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 Olar-Portconsult

More information

Shops and Businesses Page 1/5

Shops and Businesses Page 1/5 Page 1/5 Many shops and businesses rely on us on a daily basis to help with their security needs from lock changes to fully installed security systems. We carry out the following: KEY CUTTING: At Dennis

More information

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034 Guidance Note No 21/1 CE Marking Windows and doorsets to BS EN 16034 Introduction CE Marking of construction products has been a legal requirement since July 2013. It is a European requirement for all

More information

Designed to provide immediate escape, first time, every time

Designed to provide immediate escape, first time, every time Briton panic and emergency exit hardware Designed to provide immediate escape, first time, every time When lives may depend on an exit device we feel we have a responsibility to design and test our products

More information

ABLOY Unique features and benefits

ABLOY Unique features and benefits Better Than Ever ABLOY padlocks have been the market leaders for decades. Independent test results have confirmed that ABLOY padlocks continue to operate smoothly after the toughest corrosion tests. They

More information

High Security Locking. Product Catalogue

High Security Locking. Product Catalogue High Security Locking Product Catalogue An ASSA ABLOY Group company 2 Adams Rite Europe Limited About the company Adams Rite was formed in 1946 in Los Angeles, California and over the years we have created

More information

NEW GENERATIONS. We secure the world

NEW GENERATIONS. We secure the world NEW GENERATIONS We secure the world Standard-pin tumbler system Coded side bar locking system Drill-resistant cylinder housing ASSA Twin V-10,Twin Exclusive and Twin Pro High Security Cylinders The ASSA

More information

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device 01-02-2012 Evaluation guideline for the Kiwa product certificate for Compression fittings to tighten with matching clamping device Preface This evaluation guideline has been accepted by the board of experts

More information

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors. PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: SECTION 08710 FINISH HARDWARE 1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors. 2. Types

More information

NFPA 80 Overview January 21, 2016

NFPA 80 Overview January 21, 2016 NFPA 80 Overview January 21, 2016 Kristin Bigda, P.E. Senior Fire Protection Engineer National Fire Protection Association Presenter Kristin Bigda, P.E. Senior Fire Protection Engineer, NFPA Building Fire

More information

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe EI 2 30-C5-S 200 do you know what it means? EN 16034 CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe Dipl.-Ing. Jürgen Benitz-Wildenburg, Director PR &

More information

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012 KE 191 - A1 March 2012 GASTEC QA Evaluation Guideline KE 191 Amendment A1 Excess flow valves Foreword and introduction These GASTEC QA Approval requirements amendment have been accepted by the Board of

More information

GUARDIAN - SPECIALIST ESCAPE LOCKS

GUARDIAN - SPECIALIST ESCAPE LOCKS Fire Safety Technical Guide GUARDIAN - SPECIALIST ESCAPE LOCKS Notes on Fire Escape Door Locks In general, doors on escape routes (whether or not the doors are fire doors), should either not be fitted

More information

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ Technical regulation on safety of low-voltage equipment Part I Сближение ЕС и РФ в области технического регулированияь стандардизации и систем сертификации» АФНОР/ДИН/БСИ/СВЕДАК Контракт н. 2009/214-140 Проект финансируется Европейским Союзом Approximation of EU and

More information

An ASSA ABLOY Group brand. MECHANICAL LOCK CASES Technical descriptions

An ASSA ABLOY Group brand. MECHANICAL LOCK CASES Technical descriptions An ASSA ABLOY Group brand MECHANICAL LOCK CASES Technical descriptions Contents General information...2-3 Locks for interior doors ABLOY 2011... 4 ABLOY 2014... 4 ABLOY 2016... 4 ABLOY 2018... 5 ABLOY

More information

Electromagnetic Locking Devices

Electromagnetic Locking Devices Electromagnetic Locking Devices to DHF TS 010:2016 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Electromagnetic Locking Devices to DHF TS 010:2016 dhf Best Practice s This publication

More information

Hinged Security Door Hardware

Hinged Security Door Hardware Hinged Security Door Hardware 10YEAR 1 Whitco Hinged Security Door Catalogue whitco.com.au Contents Tasman Mk3 Tasman MK2 Tasman Escape Safety Lock page 3 page 5 page 7 page 9 Screen Door Latch Screen

More information

DIVISION 10 SPECIALTIES

DIVISION 10 SPECIALTIES DIVISION 10 SPECIALTIES 11/11 SECTION 10 21 13.16 PLASTIC LAMINATE TOILET COMPARTMENTS PART 1 - GENERAL 1.01 SECTION INCLUDES Plastic laminate toilet compartments, urinal screens, head rail braced. 1.02

More information

Sliding Security Screen Door Hardware

Sliding Security Screen Door Hardware Sliding Security Screen Door Hardware Leichhardt Application/Description Single & Multi point mortice sliding security door lock. Features and Specifications Suits either Left or Right hand closing sliding

More information

MECHANICAL LOCK CASES Technical descriptions

MECHANICAL LOCK CASES Technical descriptions MECHANICAL LOCK CASES Technical descriptions Abloy Oy An ASSA ABLOY Group company Contents General information...2-3 Locks for interior doors ABLOY 2011... 4 ABLOY 2014... 4 ABLOY 2016... 4 ABLOY 2018...

More information

Specification, installation & maintenance of fire doors: Technical Note 2

Specification, installation & maintenance of fire doors: Technical Note 2 Specification, installation & maintenance of fire doors: Technical Note 2 March 2016 You & Your Care \\raptor\user data\users\kbyard www.bdct.nhs.uk Karen Byard: Fire Officer Tel: 07946 413 331 Karen.byard@bdct.nhs.uk

More information

Alarm response definitions

Alarm response definitions Police Communications Centre 2 Clayton Street Midland WA 6056 Tel: 9374 4003, Fax: 9374 4041 Partnerships in Policing Alarm Response Working Group Alarm response definitions Commercial alarms Hold-up alarm

More information

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house THIS DOES NOT COVER 3 STOREY PROPERTIES you must consult with the Private Sector Housing Team on any 3 storey property.

More information

ASSA Lockcases. ASSA ABLOY, the global leader in door opening solutions

ASSA Lockcases. ASSA ABLOY, the global leader in door opening solutions ASSA ASSA ABLOY, the global leader in door opening solutions 2 The global leader in door opening solutions ASSA is part of the ASSA ABLOY Group, the global leader in door opening solutions operating in

More information

1.4 Provide and fix the following ironmongery.

1.4 Provide and fix the following ironmongery. Schedule of works required for Fire Protection in a first & second floor purpose built masionette above shops where the exit door is at first floor level. THIS DOES NOT COVER NORMAL 3 STOREY PROPERTIES

More information

INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools

INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools DSA Guidelines for Door Locking Hardware in Schools Egress doors shall be readily openable from the egress side without

More information

HIGH SECURITY VAULT DOORS. A complete line of high security attack-resistant vault doors and accessories. AN ISO 9001 CERTIFIED COMPANY

HIGH SECURITY VAULT DOORS. A complete line of high security attack-resistant vault doors and accessories. AN ISO 9001 CERTIFIED COMPANY HIGH SECURITY VAULT DOORS A complete line of high security attack-resistant vault doors and accessories. AN ISO 9001 CERTIFIED COMPANY OVERVIEW For more than 50 years, Overly Door Company has been an industry

More information

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to BS EN 16034: 2014 Permission to reproduce extracts from BS EN 16034 : 2014 is granted by BSI. DHF BEST PRACTICE

More information

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances 1st February 2011 regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances Foreword This has been adopted by the Kiwa Board of Experts of Energy

More information

Contents EN :2006+A2:2016 (E)

Contents EN :2006+A2:2016 (E) Contents European foreword... 6!Introduction"... 8 1 Scope... 9 2 Normative references... 10 2.1 Classification standards... 10 2.2 Test and calculation standards... 10 2.3 Other standards... 12 3 Terms

More information

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems 5 August 2014 Certification of Alarm Communication Certification (ATS) Kiwa N.V. - 1-5 Augustus 2014 Preface This Evaluation Guideline (Certification Scheme) has been accepted by the Kiwa Board of Experts

More information

ABLOY PADLOCKS UNSURPASSED PERFORMANCE

ABLOY PADLOCKS UNSURPASSED PERFORMANCE ABLOY PADLOCKS UNSURPASSED PERFORMANCE The right materials, design and production methods make ABLOY Padlocks the only choice in harsh conditions. 2 Better Than Ever ABLOY padlocks have been the market

More information

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms ECB S R11 Content 1 Preamble... 2 2 Scope and purpose... 2 3 Normative

More information